Coriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM

Size: px
Start display at page:

Download "Coriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM"

Transcription

1 MAXIFO TM Features MaxiFlo Coriolis Mass Flowmeter series MCM is a mass flow meter that measures mass flow, density and temperature of liquids, slurries and gases. And it even measures oil content in water. It has no moving parts and doesn't require any special device for installation. And it doesn t require flow profile stabilization by means of flow straightener or straight pipe run either upstream or downstream. The wetted parts are made of high-grade stainless steel (SUS316) and therefore can be used for corrosive liquids. DSP (digital signal processing) technology assures high accuracy of 0.1%, 0.2% and 0.5% of reading and a wide turndown ratio Can measure liquids of all types, slurries and gases. Wetted parts are made from high-grade stainless steel and can be used for corrosive liquids Mass flow, volume flow, density and temperature measurement without additional instruments Measurement accuracy is not affected by the flow profile (laminar or turbulent) and therefore, there's no need for flow profile stabilization by means of flow straightner or straight pipe sections either upstream or downstream Minimal pressure loss No moving parts in the flow, longer life and easy maintenance Measuring Principle of Coriolis MFM 100% Customer Satisfaction Coriolis Mass Flowmeter (MCM Series) Integral Type with U type sensor Coriolis Mass Flowmeter The mass flow-sensing element is composed of a pair of bent tubes, vibrators and displacement sensors. The trick here is to detect the Coriolis force applied on the tube by the flowing fluid inside the bent oscillating tube. In order to do that, the vibrators vibrate the bent tubes at the natural resonant frequency of the tubes. When there's a flow inside the tubes, the Coriolis force at work distorts the vibration of the tubes. This distortion can be measured using the displacement sensors. The amount of distortion is directly proportional to the mass flow of the fluid inside the tube. By accurately processing the displacement, the accurate mass flow is directly measured. iquids, slurries and gases can be measured. It boasts strong immunity to noise, high accuracy, wide turndown ratio, stability and reliability. Integral Type with Half-circle Sensor Integral Type with Triangular Sensor

2 MAXIFO TM Flow Rates Table (mm) Allowable Flow Range (kg/h) For iquids Normal Flow Range for Accuracy 0.1% (kg/h) U Type Normal Flow Range for Accuracy 0.2% & 0.5% (kg/h) Zero Stability(kg/h) ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ Half-Circle Type ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ( mm ) Allowable Flow Range ( kg/h ) For Gases Normal Flow Range with Accuracy 0.5% ( kg/h ) Zero Stability ( kg/h ) ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~

3 MAXIFO TM Outline Dimensions and Weights Integral Type Remote Type H H H 4.0MPa 6.3MPa Integral Remote Net Weight (kgs) H 1 H 6.3MPa Integral Remote Net Weight (Kgs) 4.0MPa Remote Transmitter Weight: 5 kgs

4 MAXIFO TM Technical Specifications Transmitter Sensor Sizes Medium Measured Variables Working Temperature Working Pressure Working Environment Output Power Supply Ingress Protection Explosion Proof Integral / Remote Type U type, half-circle type and triangular type 10 ~ 200mm iquid, gas, slurry - Accuracy / Repeatability (±%): Flow iquid 0.1 / 0.05, 0.2 / 0.1, 0.5 / 0.25 Gas: 0.5 / Range: 0.2 ~ 3.0 g/cm 3 Density - Accuracy: ±0.02 g/cm 3 - Repeatability: g/cm 3 - Range: -150 ~ 400 Temperature - Accuracy: ±1.0 - Measurement of water content in oil in % Water-cut - Accuracy: ±2% Integral type: -50 ~ 125 Remote type: -50 ~ 200 Remote type with high temperature option: -50 ~ 300 Remote type with low temperature option: -150 ~ , 2.5, 4.0, 6.3 MPa High pressure available upon request - Frequency: <2000Hz Vibration - Acceleration: <2G (Note: 1G = 9.8 ) Temperature Humidity 4-20mA Frequency Pulse RS Operation: -40 ~ +55 Storage: -20 ~ +70 at +25 without condensation Operation: <90% - Storage: <95% - 2-wire, loop-powered - oad Resistance: 250 ~ 600 Ohm - Error: ±0.2% F.S - OCT (Open Collector, Dry Contact) - Range: 0 ~ 10 KHz - Error:±0.075% MODBUS-RTU - DC: 18 ~ 30V, Consumption 10 ~ 15W - AC: 85 ~ 265V, Consumption 10 ~ 15W IP-65 Integral Type Remote Type Exdib IIC T4 ~ 6 10 ~ 80 Exib IIC T3 ~ ~ 200 Exdib IIC T3 ~ 6

5 MAXIFO TM Model Selection Code MCM-### - # - # - # - ## - ## - # Nominal Size ### Converter Type Sensor Medium Integral Remote U-shape sensor Half circle sensor Triangular sensor iquid Gas I R U H T G Power 220 VAC P1 24 VDC P2 Connections JIS Flange ANSI Flange DIN Flange Other F1 F2 F3 F4 0.1% A Accuracy 0.2% B 0.5% C Options 4-20mA with HART H For example: MCM-050-I-H-G-P1-F1-C A 50mm, 220VAC-powered Coriolis mass flow meter with an integral half-circle sensor with JIS flange to measure a gas with an accuracy of 0.5%

6 We are here for you For further information, visit us at Subject to change without prior notice 12/08 Printed in Korea Seil Enterprise co The information contained in this catalog contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in terms of the contract. All product designations may be trademarks or product names of Seil Enterprise Co. whose use by third parties for their own purposes could violate the rights of the owners. Seoul Korea MAXIFO TM is a registered trademark of

Electromagnetic Flowmeter

Electromagnetic Flowmeter Overview Flokal B.V. smart electromagnetic flow meter is hallmarked by its high performance and reliability that are based on successful, field-proven technology. It s being widely used in industries such

More information

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,

More information

tekcor TKC Multivariable Coriolis Flow Sensors

tekcor TKC Multivariable Coriolis Flow Sensors Sensing the pulse of industry Technical Data Sheet & General Specifications tekcor TKC Multivariable Coriolis Flow Sensors The tekcor TKC Series principle was initiated by tekflo sensors engineers, who

More information

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement

More information

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,

More information

Applicable Fluid. Accuracy. Flow Rate Range. Fluid Temperature. Fluid Viscosity. Connection Size. Flange Rating. Housing. Material. Blade.

Applicable Fluid. Accuracy. Flow Rate Range. Fluid Temperature. Fluid Viscosity. Connection Size. Flange Rating. Housing. Material. Blade. TOKICO TURINE METER GS-F211E- Overview Turbine meter has an excellent performance with its distinctive structure. Comparing with the flow meter using other method, it has compact and lighter design and

More information

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,

More information

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181 Siemens AG 09 SITRANS F flowmeters System information Overview Siemens offers two types of ultrasonic flowmeters, in-line flowmeters and clamp-on flowmeters. This offers the end user the maximum flexibility

More information

Integral V-Cone Flowmeter VD series

Integral V-Cone Flowmeter VD series TRANSMITTER DIRECTLY MOUNTED! SIMPLE AND EASY INSTALLATION Integral V-Cone Flowmeter VD series OUTLINE VD series Integral V-Cone Flowmeter is a differential pressure type flowmeter. Unlikely to existing

More information

MODEL: CR002, CR003, CR004. ADC12 Display shield. Liquid (Density range: 0.3 to 2.0g/mL) Operating temperature range

MODEL: CR002, CR003, CR004. ADC12 Display shield. Liquid (Density range: 0.3 to 2.0g/mL) Operating temperature range Liquid Inexpensive Microflow Coriolis Flowmeter CoriMate Ⅱ MODEL: CR002, CR003, CR004 GENERAL Based on the knowledge and experience on Coriolis technologies OVAL has gained over many years, the Corimate

More information

ULTRA OVAL Meter Sizes:39, 41, 45, 50, 52, 53 w/unfactored Pulse Generator (NPG60A)

ULTRA OVAL Meter Sizes:39, 41, 45, 50, 52, 53 w/unfactored Pulse Generator (NPG60A) ULTRA OVAL Meter Sizes:9, 4, 45, 50, 5, 5 w/unfactored Pulse Generator (NPG60A) GENERAL SPECIFICATION GS.No.GBU0--E GENERAL ULTRA OVAL MODEL 9, 4, and45 provides extensive capability as a highly dependable

More information

IN-FLOW Industrial Style Digital Mass Flow Meters and Controllers for Gases

IN-FLOW Industrial Style Digital Mass Flow Meters and Controllers for Gases IN-FLOW Industrial Style Digital Mass Flow Meters and Controllers for Gases > Introduction Bronkhorst High-Tech B.V., the European market leader in low flow thermal and Coriolis Mass Flow Meters/Controllers,

More information

Ultrasonic Gas Flow Meter

Ultrasonic Gas Flow Meter P r o d u c t i n f o r m at i o n FLOWSIC600 Ultrasonic Gas Flow Meter For custody transfer and process applications Analyzers and Process Instrumentation FLOWSIC600 For Custody Transfer and Process Applications

More information

ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY

ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo 22 36054 Montebello Vicentino (VI) - ITALY www.abb.com/transformercomponents The information contained in this document is for general information

More information

Pressure transmitters for industrial applications MBS 32 and MBS 33

Pressure transmitters for industrial applications MBS 32 and MBS 33 Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer

More information

CORIOLIS MASS FLOW METERS FOR GAS AND LIQUID MEASUREMENT. Michael Keilty (Presented by Hubbard Donald) Endress + Hauser Flowtec AG

CORIOLIS MASS FLOW METERS FOR GAS AND LIQUID MEASUREMENT. Michael Keilty (Presented by Hubbard Donald) Endress + Hauser Flowtec AG Introduction CORIOLIS MASS FLOW METERS FOR GAS AND LIQUID MEASUREMENT Michael Keilty (Presented by Hubbard Donald) Endress + Hauser Flowtec AG A mass flowmeter is a system that provides a measurement of

More information

DELTA FLOWMETER FOR GAS SERVICE (INSERTION TYPE) MODEL VF SERIES

DELTA FLOWMETER FOR GAS SERVICE (INSERTION TYPE) MODEL VF SERIES DETA FOWMETER FOR GAS SERVICE (INSERTION TYPE) MODE VF SERIES GENERA SPECIFICATION GS. No. GBD0-0-E GENERA In the thermistor type Delta meter, a probe inserted in the pipeline detects the representative

More information

Fitting PS P - B - R2

Fitting PS P - B - R2 INTERNAL STRUCTURE PS86 (G 3/8) 2 3 FEATURES Solidstate pressure switch with no mechanical moving parts Isolated output via a photo-coupler Switching pressure adjustable and hysteresis band adjustable

More information

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis mass flowmeter

CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis mass flowmeter Data Sheet DS/FCB100/FCH100-EN Rev. D CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis mass flowmeter High precision measurement of mass and volume flow, density, temperature and concentration with

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

AM-1000 Series COMPACT FLOWMETER

AM-1000 Series COMPACT FLOWMETER METAL TUBE VARIABLE AREA FLOWMETER AM0 Series COMPACT FLOWMETER GENERAL AM0 series are most well accepted metal tube flowmeters which have been developed based on the long time experience of TOKYO KEISO

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30 eries Features Best pressure transmission solution for small and middle sized project such as indoor heating and air conditioning, water and sewer, or incinerator, etc. Improves noise resistance and minimize

More information

AM-1000 Series COMPACT FLOWMETER

AM-1000 Series COMPACT FLOWMETER METAL TUBE VARIABLE AREA FLOWMETER AM0 Series COMPACT FLOWMETER GENERAL AM0 series are most well accepted metal tube flowmeters which have been developed based on the long time experience of TOKYO KEISO

More information

Metso Concentration Measurement 3300

Metso Concentration Measurement 3300 Metso Concentration Measurement 3300 Metso Concentration 3300 Accurate direct in-line measurement The Concentration Measurement is provided with intelligent technology calculating the concentration of

More information

Coriolis in the Marine Industry TRICOR Coriolis Technology. All rights reserved.

Coriolis in the Marine Industry TRICOR Coriolis Technology. All rights reserved. Coriolis in the Marine Industry 1 Advantages Coriolis Meters Direct Measurement of Mass, Temp, Density Indirect measurement of Volume and Concentration (e.g. BRIX) Accuracy - high precision Swiss Watch

More information

Target Insertion Flowmeter

Target Insertion Flowmeter Principle of Operation Flow is measured in terms of dynamic force acting on a target (solid disk) in the flow stream. Hermetically sealed, bonded strain gages in a bridge circuit configuration mounted

More information

Cone differential pressure flow meter. Operating manual WIDE PLUS PRECISION INSTRUMENTS CO., LTD.

Cone differential pressure flow meter. Operating manual WIDE PLUS PRECISION INSTRUMENTS CO., LTD. Cone differential pressure flow meter Operating manual WIDE PLUS PRECISION INSTRUMENTS CO., LTD. INDEX Introduction 2 Principle Application The characteristics of flow meter Specification Technical features

More information

MX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E

MX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E OMPT ND USER FRIENDLY MX Series Metal Tube Type Variable rea Flowmeter OUTLINE MX Series flowmeter is the metal tube type variable area flowmeter having the unified face-to-face dimension. The compact

More information

Information Technology Solutions Neptune Datasheet

Information Technology Solutions Neptune Datasheet Information Technology Solutions Neptune Datasheet Suspended Solids Analyzer Neptune is the first purpose built in-situ analyzer for measuring the suspended solids of slurries. Specifically developed for

More information

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar

More information

VORTEX FLOWMETER (DELTA FLOWPET)

VORTEX FLOWMETER (DELTA FLOWPET) VORTEX FOWMETER (DETA FOWPET) DATA SHEET FMR, M This instrument is a Karman vortex flowmeter capable of measuring the flow rate of liquid, gas, and vapor. The heavyduty detecting section made of stainless

More information

CoriolisMaster FCB430, FCB450, FCH430, FCH450 Coriolis mass flowmeter

CoriolisMaster FCB430, FCB450, FCH430, FCH450 Coriolis mass flowmeter Data Sheet DS/FCB400/FCH400-EN Rev. D CoriolisMaster FCB430, FCB450, FCH430, FCH450 Coriolis mass flowmeter High precision measurement of mass and volume flow, density, temperature and concentration with

More information

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO. DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link

More information

CoriolisMaster FCB/FCH150 and FCB/FCH450 Simultaneous recording of flow rate and density / concentration for the food and beverage industry

CoriolisMaster FCB/FCH150 and FCB/FCH450 Simultaneous recording of flow rate and density / concentration for the food and beverage industry Change from one to two columns Application note AN/CORIOLIS/108-EN Rev. A CoriolisMaster FCB/FCH150 and FCB/FCH450 Simultaneous recording of flow rate and density / concentration for the food and beverage

More information

DOG-1/-3. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air : 120 C. p max. : PN 40; t max

DOG-1/-3. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air : 120 C. p max. : PN 40; t max Oscillation Flowmeter for gases measuring monitoring analysing DOG1/3 Measuring ranges: 0.2 20... 200 20000 m 3 /h air p max : PN 40; t max : 120 C Connection: flange DN 25... DN 400 Material: cast iron,

More information

Applied Fluid Mechanics

Applied Fluid Mechanics Applied Fluid Mechanics 1. The Nature of Fluid and the Study of Fluid Mechanics 2. Viscosity of Fluid 3. Pressure Measurement 4. Forces Due to Static Fluid 5. Buoyancy and Stability 6. Flow of Fluid and

More information

Full Metal Variable Area Flow Meter and Counter

Full Metal Variable Area Flow Meter and Counter Full Metal Variable rea Flow Meter and Counter for horizontal and vertical mounting measuring monitoring analysing Special versions up to 600 bar Measuring range: 10-100...00-000 L/h water 0.3-3.0...-0

More information

Volumetric Flow Measurement

Volumetric Flow Measurement Volumetric Flow Measurement TVF Series Vortex Flow Meter Xi an Tosilon Automation Co., Ltd No.299, Daqing Rd, Lianhu District, Xi'an Shaanxi, China Tel: +86-29-8823 8550 info@tosilon.com; www.tosilon.com

More information

Applied Fluid Mechanics

Applied Fluid Mechanics Applied Fluid Mechanics 1. The Nature of Fluid and the Study of Fluid Mechanics 2. Viscosity of Fluid 3. Pressure Measurement 4. Forces Due to Static Fluid 5. Buoyancy and Stability 6. Flow of Fluid and

More information

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet High-efficiency Circulator Pump Rio-Eco N / Rio-Eco Z N Type Series Booklet Legal information/copyright Type Series Booklet Rio-Eco N / Rio-Eco Z N KSB Aktiengesellschaft All rights reserved. The contents

More information

K Series SIGHT GLASS FOR CONVENIENT OBSERVATION OF LIQUID FLOW GENERAL

K Series SIGHT GLASS FOR CONVENIENT OBSERVATION OF LIQUID FLOW GENERAL FOR CONVENIENT OBSERVATION OF IQUID FOW K Series SIGHT GASS GENERA K series are sight glasses for observation of various liquids. Different types are available to meet applications and requirements. Cast

More information

5SJ4...-.HG Circuit Breakers to IEC and UL 489

5SJ4...-.HG Circuit Breakers to IEC and UL 489 Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is

More information

Field IT 50T Series Transmitters

Field IT 50T Series Transmitters Data Sheet SS/G/A_ Field IT 0T Series Transmitters gauge/absolute pressure transmitter Ranges: -00 to 0000kPa - to 00bar -. to 6000psi Base accuracy : 0.% (BFSL) Chemical Vapour Deposition (CVD) technology

More information

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up

More information

Reference 1 Thermal Energy Metering. Abstract: Some aspects of the selection and installation requirements for thermal energy metering are canvassed.

Reference 1 Thermal Energy Metering. Abstract: Some aspects of the selection and installation requirements for thermal energy metering are canvassed. Reference 1 Thermal Energy Metering Project Reference: Metering_Thermal Industry or sector: All Energy use: All Date added: Sep 2011 Thermal Energy Metering Abstract: Some aspects of the selection and

More information

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product. Safety Precautions Observe the following notices to ensure personal safety or to prevent accidents. To ensure that you use this product correctly, read this User s Manual thoroughly before use. Make sure

More information

Vortex Flow Meters. RVL Series Vortex Flow Meter

Vortex Flow Meters. RVL Series Vortex Flow Meter TM Vortex Meters RVL Series Vortex Meter pplications: Water/Wastewater I Water: Semiconductor, Institutional I Water Skids Semiconductor Equipment Slurry hemical Processing RINE FEERTE IN. ISO 900 : 000

More information

Digital Thermal Mass Flow Meters and Controllers for Gases

Digital Thermal Mass Flow Meters and Controllers for Gases EL-FLOW Select Digital Thermal Mass Flow Meters and Controllers for Gases > Introduction Bronkhorst High-Tech B.V., the European market leader in low flow thermal and Coriolis Mass Flow Meters/Controllers,

More information

V-Cone Flowmeter DATASHEET

V-Cone Flowmeter DATASHEET V-Cone Flowmeter ATASHEET JUNHO 013 IntraCone Cone Flow Meter Type: ICM etail: Cone-Element Technical Information 05/011 FLOW THE SPECIALIST IN LEVEL AN FLOW Cone Flow Meter Technical Information Intra-Automation

More information

Rocky Mountain Measurement Seminar Denver August 20, 2015 Coriolis Meters

Rocky Mountain Measurement Seminar Denver August 20, 2015 Coriolis Meters Cover graphic should fill and not exceed the defined grey box. Rocky Mountain Measurement Seminar Denver August 20, 2015 Coriolis Meters Sales Talks from the Early Years New Religion All our worries are

More information

By-Pass. This voltage is proportional to the liquid level (threewire potentiometer circuit). The resistance reading can

By-Pass. This voltage is proportional to the liquid level (threewire potentiometer circuit). The resistance reading can " " ' " ' / The magnetic field which is in the ball or cylindrical floats actuates very small reed contacts through the wall of a guide tube and these pick up an uninterrupted measuring-circuit voltage

More information

Instrumentation & Data Acquisition Systems

Instrumentation & Data Acquisition Systems Instrumentation & Data Acquisition Systems Section 5 -Flow Robert W. Harrison, PE Bob@TheHarrisonHouse.com Made in USA 1 The Perfect Flowmeter Infinite rangeability / turndown with negligible uncertainty

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output

More information

14:1400 (0206) KRAL Volumeter - OMG

14:1400 (0206) KRAL Volumeter - OMG 14:1400 (0206) KRAL Volumeter - OMG OMG - Universal OMG The flowmeter for a wide range of applications Operating Conditions and Materials Flow Range: 0.1 to 7,500 l/min Max. Pressure: 250 bar Temperature

More information

TF-1000 Series MINI THERMAL MASS FLOWMETER PERFECT LINE-UP, BEST COST PERFORMANCE OUTLOOK FEATURES OPERATION PRINCIPLE PRODUCT LINE-UP

TF-1000 Series MINI THERMAL MASS FLOWMETER PERFECT LINE-UP, BEST COST PERFORMANCE OUTLOOK FEATURES OPERATION PRINCIPLE PRODUCT LINE-UP PERECT INE-UP, EST COST PERORMNCE T-000 Series MINI TERM MSS OWMETER OUTOOK T-000 MINI TERM MSS OWMETERS are designed and developed to offer the remote indication and control of gas flow process where

More information

Tecnología en Electrónica y Control SRL Ficha Técnica

Tecnología en Electrónica y Control SRL Ficha Técnica Tecnología en Electrónica y Control SRL Ficha Técnica Caudalímetros Tecnología en Electrónica y Control SRL Oficina Central Wüthrich 949 San Carlos Centro (S3013DES) / Santa Fe / Argentina Tel./Fax/Líneas

More information

S95.3U02 / S95.3U12. Head mounted temperature transmitters, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation

S95.3U02 / S95.3U12. Head mounted temperature transmitters, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation S95.U0 / S95.U Head mounted temperature transmitters, HART programmable, Pt 00 (RTD), thermocouples, electrical isolation Resistance thermometer (,, wire circuit) Thermocouples Resistance remote signalling

More information

ONYX -MCE MULTI-CHANNEL OPTICAL FIBER PYROMETERS WITH ACTIVE EMISSIVITY COMPENSATION PRECISION TEMPERATURE MEASUREMENT FOR DEMANDING INDUSTRIAL

ONYX -MCE MULTI-CHANNEL OPTICAL FIBER PYROMETERS WITH ACTIVE EMISSIVITY COMPENSATION PRECISION TEMPERATURE MEASUREMENT FOR DEMANDING INDUSTRIAL ONYX -MCE MULTI-CHANNEL OPTICAL FIBER PYROMETERS WITH ACTIVE EMISSIVITY COMPENSATION PRECISION TEMPERATURE MEASUREMENT FOR DEMANDING INDUSTRIAL APPLICATIONS Accurate, repeatable, and reliable temperature

More information

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C ASH & ALAIN INDIA PVT LTD S-00, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-000(India) Tel : 0-797575 Fax : 0-79757 E-mail : sales@ashalain.com Proximity Ideal for High Temperatures and Cleaning

More information

close to performances of the turbine gas meters designed for custody transfer measurements.

close to performances of the turbine gas meters designed for custody transfer measurements. QUANTOMETER DESIGN AND FUNCTION CPT Quantometers have been designed in order to provide our customers with reliable and inexpensive measuring instruments for secondary flow measurements. Our great experience

More information

Relative pressure transmitter type 520

Relative pressure transmitter type 520 Relative pressure transmitter type 520 Pressure range The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the pressure measuring cell is fully

More information

FLOW MEASUREMENT. INC 102 Fundamental of Instrumentation and Process Control 2/2560

FLOW MEASUREMENT. INC 102 Fundamental of Instrumentation and Process Control 2/2560 FLOW MEASUREMENT INC 102 Fundamental of Instrumentation and Process Control 2/2560 TABLE OF CONTENTS A. INTRODUCTION B. LOCAL FLOW MEASUREMENT B.1 Particle Image Velocimetry (PIV) B.2 Laser doppler anemometry

More information

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes Examples of Application Flow measurements also in hazardous locations X zone 0 or zone 1 in clean rooms in air

More information

Technical specification FLUXUS F502TE

Technical specification FLUXUS F502TE Technical specification FLUXUS F502TE Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate Precise and intelligent energy measuring

More information

Coriolis Mass Flow Measurement System promass 60 (HART)

Coriolis Mass Flow Measurement System promass 60 (HART) Technical Information TI 029D/06/en No. 5006899 Coriolis Mass Flow Measurement System promass 60 (HART) Cost-effective mass flow measurement for liquids and gases Flexible System The system can be customised

More information

Digital display Pressure range ON/OFF output Linear output Model No Positive pressure 0 to 98 kpa (0 to 1 kgf/cm 2 ) NPN open collector o 1 to o5

Digital display Pressure range ON/OFF output Linear output Model No Positive pressure 0 to 98 kpa (0 to 1 kgf/cm 2 ) NPN open collector o 1 to o5 Pressure Sensor E8CC with Built-in Microcomputer and Digital Display and New E8CB General-purpose Model Withstands a of 490 kpa (5 kgf/cm 2 ) and highly reliable. Incorporates a two-turn adjuster ensuring

More information

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels TF 0 / TF 0-Ex Field mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.69 EN USA Input Resistance thermometer (,, wire circuit) Thermocouples

More information

COMPACT FLOWMETER TO COVER ALL POSSIBLE APPLICATIONS. METAL TUBE AM-1000 Series GENERAL FEATURES TG-F962-0E APR.,2000 AM-1000 COMPACT FLOWMETER

COMPACT FLOWMETER TO COVER ALL POSSIBLE APPLICATIONS. METAL TUBE AM-1000 Series GENERAL FEATURES TG-F962-0E APR.,2000 AM-1000 COMPACT FLOWMETER AM0 TO COVER ALL POSSIBLE APPLICATIONS METAL TUBE AM0 Series GENERAL AM0 series are most well accepted metal tube flowmeters which have been developed based on the long time experience of TOKYO KEISO in

More information

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows: The basic PC software is supplied free with the recorder. There is an additional charge for the extensive Data Acquisition Software supplied with communication of RS-232/422/485 or Ethernet. The Ordering

More information

Flow Monitoring Technologies in Oil and Gas. Don Ford, Technical Specialist Spartan Controls Ltd.

Flow Monitoring Technologies in Oil and Gas. Don Ford, Technical Specialist Spartan Controls Ltd. Flow Monitoring Technologies in Oil and Gas Don Ford, Technical Specialist Spartan Controls Ltd. Agenda Flow technologies at a glance Oil and Gas at a glance Select Flow Technologies in Depth Differential

More information

PG-200/PG-208 PRESSURE GAUGES P G G P P

PG-200/PG-208 PRESSURE GAUGES P G G P P Digital 3 1/2 digits monitor Set button for switch output HI or LO (PG-200) (PG-208) Digital 3 1/2 digits Power switch LO setting VR for switch output LO HI setting VR for switch output HI SPAN adjustment

More information

VersaFlow Ultrasonic clamp-on Flowmeter Specifications

VersaFlow Ultrasonic clamp-on Flowmeter Specifications VersaFlow Ultrasonic clamp-on Flowmeter Specifications 34-VF-03-14 September 2009 Clamp-On Technology HONEYWELL S VersaFlow stands for continuity and long term reliability. Flow measurement can be done

More information

v = 00,20 m/s Thermal Flow Sensors TA with thin-film sensor element Probes Probe guides Measuring tubes

v = 00,20 m/s Thermal Flow Sensors TA with thin-film sensor element Probes Probe guides Measuring tubes with thin-film sensor element Probes Probe guides Measuring tubes Examples of Application Flow measurements also in hazardous locations Ex zone 0 or zone 1 in clean rooms in air conditioning and ventilating

More information

50/60 Hz. ecocirc XL and XLplus. high efficiency WET ROTOR circulators. ErP 2009/125/EC

50/60 Hz. ecocirc XL and XLplus. high efficiency WET ROTOR circulators. ErP 2009/125/EC / Hz ecocirc XL and XLplus high efficiency WET ROTOR circulators FOR COMMERCIAL HEATING AND COOLING applications ErP 9/1/EC Cod. 1971 Rev. C Ed.11/1 Lowara, ecocirc, Xylect are trademarks of Xylem Inc.

More information

TSK. Flap-Type Flowmeter. Range: to GPM Accuracy: ± 2.5% of Full Scale P max. : 580 PSI T max

TSK. Flap-Type Flowmeter. Range: to GPM Accuracy: ± 2.5% of Full Scale P max. : 580 PSI T max Flap-Type Flowmeter measuring monitoring analyzing TSK Range: 6.6...26.4 to 880...6600 GPM Accuracy: ± 2.5% of Full Scale P max : 580 PSI T max : -40 572 F Connection: Wafer Flange 1.5" 20" ASME Material:,

More information

Reflex-Radar BM 100 A

Reflex-Radar BM 100 A KROHNE 09/2001 7.02317.22.00 GR/PRINTO Reflex-Radar The universal TDR level gauge for liquids, solids and interface Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters

More information

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation S95.U0 / S95.U Head mounted temperature transmitters, programmable, Pt 00 (RTD), thermocouples, electrical isolation Resistance thermometer (,, wire circuit) Thermocouples Resistance remote signalling

More information

SVH with HYDROVAR (HVL range)

SVH with HYDROVAR (HVL range) SVH with HYDROVAR (HVL range) SVH-HVL Rev. B Ed.9/1 (EN) SVH SERIES (e-sv WITH HYDROVAR) Background and context For all pumping needs in commercial or residential building and in industry applications,

More information

PRODUCT CATALOGUE PREssURE switch

PRODUCT CATALOGUE PREssURE switch PRODUCT CATALOGUE PREssURE switch w w w. p a a b. c o m Pressure AT THe HIGHesT LeVeL Successful mediumsized companies are not successful because they are active in many areas, but rather because they

More information

Today s menu. Last lecture. Measurement of volume flow rate. Measurement of volume flow rate (cont d...) Differential pressure flow meters

Today s menu. Last lecture. Measurement of volume flow rate. Measurement of volume flow rate (cont d...) Differential pressure flow meters Last lecture Analog-to-digital conversion (Ch. 1.1). Introduction to flow measurement systems (Ch. 12.1). Today s menu Measurement of volume flow rate Differential pressure flowmeters Mechanical flowmeters

More information

An Essential Requirement in CV Based Industrial Appliances.

An Essential Requirement in CV Based Industrial Appliances. Measurement of Flow P M V Subbarao Professor Mechanical Engineering Department An Essential Requirement in CV Based Industrial Appliances. Mathematics of Flow Rate The Scalar Product of two vectors, namely

More information

Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate

Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate Technical specification FLUXUS F502TE Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate Stationary ultrasonic clamp-on system for

More information

Industrial Pressure Transmitter

Industrial Pressure Transmitter ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter

More information

E8EB-N0C2B E8EB-N0B2B

E8EB-N0C2B E8EB-N0B2B Slim Sensor CSM DS_E 1 Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree

More information

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

THM80X Series  Feature Application. Temperature & Humidity / Flow Measuring Specialist THM80X Series Feature Application IP67 protection degree, rugged aluminum case, fit in variety harsh environment Capable of temperature compensation Linear adjustment temperature & humidity by computer,

More information

Linearity of Coriolis Flowmeters at Full Scale Value. Dr. Jesús Aguilera - Endress + Hauser Paul Ceglia - Endress + Hauser

Linearity of Coriolis Flowmeters at Full Scale Value. Dr. Jesús Aguilera - Endress + Hauser Paul Ceglia - Endress + Hauser Linearity of Coriolis Flowmeters at Full Scale Value Dr. Jesús Aguilera - Endress + Hauser Paul Ceglia - Endress + Hauser Products Solutions Services Linearity of Coriolis flowmeters at full scale value

More information

Describe Coriolis Mass Flowmeters

Describe Coriolis Mass Flowmeters Training Module Human Development HDC Human Development All rights reserved. No part of this publication may be copied, reproduced, stored in a computer or retrieval system, published, distributed, or

More information

Hydraulic Pressure NAH Applications. Features. New generation available - refer to

Hydraulic Pressure NAH Applications. Features. New generation available - refer to NAH 8 Hydraulic Pressure Transmitter New generation available - refer to www.trafag.com/h70 Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for

More information

Online data sheet FLOWSIC600-XT GAS FLOW METERS

Online data sheet FLOWSIC600-XT GAS FLOW METERS Online data sheet T MTH F H I J K L M N O P Q R S T Ordering information Type Part no. On request The exact device specifications and performance data of the product may deviate from the information provided

More information

SLH-K Handheld Ultrasonic Flowmeter

SLH-K Handheld Ultrasonic Flowmeter SLH-K Handheld Ultrasonic Flowmeter Features High Accuracy measuring A c c u r a c y : ±1 %, l i n e a r i t y : 0. 5 %, r e p e a t a b i l i t y : 0. 2 % Wi d e m e a s u r i n g r a n g e Several types

More information

KNOWLEDGE

KNOWLEDGE MICRO MOTION WHITE PAPER BY TIM CUNNINGHAM, MICRO MOTION, INC. Using Structural Integrity Meter Verification to Track Corrosion in Coriolis Flowmeters KNOWLEDGE WWW.micromotion.com Structural Integrity

More information

Wind Speed & Direction Sensors

Wind Speed & Direction Sensors Wind Speed & Direction Sensors gillinstruments.com Gill Instruments has over twenty-five years experience in air flow measurement using ultrasonic technology and is a world leader in the field of wind

More information

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure DATASHEET Pascal ET Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure - electrical signals (ma, mv, V, ) - temperature (TC and

More information

TF-1000 Series MINI THERMAL MASS FLOWMETER PERFECT LINE-UP, BEST COST PERFORMANCE OUTLOOK FEATURES OPERATION PRINCIPLE PRODUCT LINE-UP

TF-1000 Series MINI THERMAL MASS FLOWMETER PERFECT LINE-UP, BEST COST PERFORMANCE OUTLOOK FEATURES OPERATION PRINCIPLE PRODUCT LINE-UP PERFET INE-UP, EST OST PERFORMANE TF-000 Series MINI TERMA MASS FOWMETER OUTOOK TF-000 MINI TERMA MASS FOWMETERS are designed and developed to offer the remote indication and control of gas flow process

More information

LM35 Precision Centigrade Temperature Sensors

LM35 Precision Centigrade Temperature Sensors LM35 Precision Centigrade Temperature Sensors General Description The LM35 series are precision integrated-circuit temperature sensors, whose output voltage is linearly proportional to the Celsius (Centigrade)

More information

Cooling Water Flow Regulator

Cooling Water Flow Regulator Temperature controlled, indirectly and directly actuated diaphragm valves / seat valves Port size G 3/8 to G DN 0 to DN 0 ontinuous regulation High accuracy No auxiliary energy required Technical data

More information

Multi-function, economical instrument with 4 functions in the same casing. Accessibility and safety: large-dimension terminals Insulated circuits

Multi-function, economical instrument with 4 functions in the same casing. Accessibility and safety: large-dimension terminals Insulated circuits 200 > Measurement and instrumentation Programmable digital transducers TRIAD 2 range Programmable digital transducers with to 4 analogue outputs Programmable accuracy class PRODUCT ADVANTAGES Up to 4 PROGRAMMABLE

More information

Paper # # Verification of Coriolis Flow

Paper # # Verification of Coriolis Flow 1 Paper # #2015-0164 Verification of Coriolis Flow Meter Calibration Timothy J. Cunningham Principal Engineer Micro Motion, Inc. Boulder, Colorado 80301 2 Agenda Coriolis Mass Flowmeter Theory of Operation

More information