Applicable Fluid. Accuracy. Flow Rate Range. Fluid Temperature. Fluid Viscosity. Connection Size. Flange Rating. Housing. Material. Blade.
|
|
- Bernadette Rice
- 5 years ago
- Views:
Transcription
1 TOKICO TURINE METER GS-F211E- Overview Turbine meter has an excellent performance with its distinctive structure. Comparing with the flow meter using other method, it has compact and lighter design and is also able to make highly precision measurement in the wide measurement range. This is a typical turbine meter being extensively adopted among the every industrial fields such as trading, for the use in the process management and control etc. Principle of Floating Rotor Rotor Pressure Intake Features Wide Measurement Range and High Accuracy Compared with other types of flowmeters,tokico turbine meter is much smaller and lighter and can measure accurately in a very wide flow range.the high precision integrating accuracy of ±.2% can be always maintained for business transaction purpose and ±.% for general purpose with excellent accuracy repeatability. Extremely Wide Range of Application Applicable fluid eing of stainless steel construction, the meter has was very high corrosion resistance. Therefore, the range of application is extremely wide, including water, petroleum and chemical liquids. Temperature y selecting a suitable pickup coil for the standard measuring unit according to the temperature of the fluid to be handled, the meter can be applied for a wide range of temperature from -2 to. Pressure As the housing is of pressure resistant cylindrical form, the meter can be used for high pressure fluid measuring purposes. (highest record of performance: MPa) Unique Rotor Floating Structure The rotor rotates in a floating state by a unique fluid-dynamic balancing structure, which facilitates to provide very high accuracy in a wide flow range and superb durability. Light and Compact Structure for Easy Maintenance The light and compact structure facilitates easy handling and maintenance. Enlarged Central Section Pressure Diagram Standard Specification Measuring Unit Accuracy Flow Rate Range Material Flow Direction Upper Cone Applicable Fluid Fluid Temperature Max.Working Pressure Fluid Viscosity Connection Size Flange Rating Housing lade earing Others Piping Installation Paint Color ±.2 % or ±. %.~ m /h -2 Rated Pressure of Flange mm 2 /s or below 2~ mm (/~1) J I S 1K, 2K FF or RF ASME JPI 1, RF SUS SUS1 SUS (For Capacity Model 7 or more) Super Hard Alloy SUS Lower Cone Pressure Loss Water, Petroleum, Chemical Liquid, LPG, LNG, etc From -1 to in case of the one with an intelligent counting unit (For Capacity Model or less) Horizontal Piping Silver (Painting is only applied to the counting unit)
2 Type of Preamplifier and Specifications Composition Specification Type Code Applicable Object Without Intelligent Counting Unit Standard Type Highly Sensitive Type Non-frequency Multiply Meter Frequency Multiplication Type MA NA OX PX Standard for the Capacity Model or below For the Pick Up Coil Standard for the Capacity Model or above Power Supply Current Consumption 12V DC ± 1.2V 2V DC ± 2.V ma 1 ma Output Pulse V± (Non-correction) (Floating Voltage:. V or less) 7V± (Non-correction) (Floating Voltage: V or less) V± (Non-correction) (Floating Voltage:. V or less) Load Resistance 1kΩ(+ side) 2Ω(- side) Ambient Temperature -1~ Explosion Proof Structure Explosion Proof (ExdⅡT) (Separated Type: Explosion proof (d2g) ) Explosion Proof (ExdⅡT) Wiring Transmitting Distance Wiring Connector 2-core shield wire (Core wire cross sectional area:.7 to 2 mm 2 ) 2km (When cross sectional area of core wire is.7 to 2 mm 2 ) G1/2 (PF 1/2 Female Thread) asic Model with Intelligent Counting Unit We have greatly improved maintenance performance by combining the Intelligent counting unit that has a communication function to the Turbine meter. The intelligent counting unit receives the pulse detected in the pickup coil and carries out the linearization and various corrective calculations such as the correction in volumetric expansion. And selectively displays the amount of totalized flow, momentary flow rate etc. It also outputs the pulse signal or analog signal to the receiver according to the flow volume. Also, the calculation for temperature correction is capable by connecting resistance temperature sensor from the outside. Write in or read out of the various set data and flow rate value etc. can be made by the button or smart communication. The communication signal is layered to the analog signal ( to 2mA) from digital signal after the modulation of FSK (Frequency Shift Keying), the communication can be made without use of any special communication line. Example of the Linearization +.2% Original Instrumental Error (efore Linearization) Instrumental Error Instrumental Error Curve.2% +.2% Linearization Linearization Linearization Linearization Linearization Instrumental Error After Linearization.2% Instrumental Error Curve -2-
3 Flow Range and Specification Capacity Model Conn.Size (mm) Accuracy ±.% Accuracy ±.2% 1mm 2 /s or below Minimum Flow Rate (m /h) mm 2 /s or below 1mm 2 /s or below mm 2 /s or below Max. Flow Rate (m /h) Continuous Intermittent Meter Constant (P/L) Max. Output Frequency (Hz) () Strainer Standard Screen Mesh 2 () (7) (8) (9) (1) (11) (12) (1), (1) (1) (17) (18) ,2 1,.8 2 (19) , 2,2 2.8 (2) ,, Note) 1. Capacity in ( ): former type 2. Meter constant and max.output frequency are approx. values (to be confirmed by calibration).. This table shows values for standard specification.. Continuous run means the hours of operation from 8 to 2 hours per day, Intermittent run means the operation of 8 hours or less.. 1 : Connection of models for capacity model (from 8 to ) can be made with one size smaller connection as an option.. 2 : Meter constant for the model and is the case of PX (frequency multiplying type amplifier) is used. In the case that the meter constant with intelligent counting unit,.29p/l for model and.19 P/L for model. 7. The flow rate at minimum sensitivity (flow rate that can be detected by the meter) is the 1/2 value of minimum flow rate at accuracy ±.%. Flow rate under this may not be detected. (It depends the flow rate that exceeds the minimum sensitivity may not be detected under the certain circumstance.) The range from minimum sensitivity flow rate to minimum flow rate at accuracy ±.% is out of our guarantee. Performance Characteristic In case of capacity type. Fluid : Water Frequency (Hz) Instrumental Error (%) Frequency Instrumental Error (%) Flow Rate (m /h) --
4 Standard Specification of Intelligent Counting Unit Disolay Functions Accuracy Pulse Output Analogue Output Display Totalizing Counter Reset Counter Instantaneous flow Temperature Display Mode Alarm Selection of Display * Linearization * Temperature Compensation Coefficient Compensation Measuring Chamber Thermal Expansion Compensation * Compensation of Resistance Temperature Sensor Elapsed Time since occurrence of Abnormal Condition Accuracy of linearization Computation Accuracy of Temperature Compensation Computation Analogue Output Accuracy Output Signal Description of Output Capacity of Output Pulse Width Transmission Distance Output Signal Description of Output Response Time Transmission Distance Communication Protocol Power Supply Power Consumption ackup Function Parameter Setting Waterproof Construction Explosion-Proof Construction Ambient Temperature Ambient Humidity Compensation of the Thermal Expansion of Measuring Chamber Approximate Compensation of 2-line sections ( points) (up to 1-line Sections as an option) Measurement of Elapsed time since Occurrence of Abnormal Condition Within ±. % (at the point of measurement) Within ±.7 % Within ±. % FS Select Open Drain (FET) output ( wire type or wire type), Current Pulse (2 wire type) or Voltage Pulse ( wire type) Select Compensated/ non-compensated Pulse, and Alarm Output (Note: Compensation can be selected if the temperature compensation function is available) V,.1A Select from. ~.7 ms, ~ 1 ms, ~ 1 ms 1 km or less (For 1.2 mm 2 Cable Conductor), 2 km or less (For 2 mm 2 Cable Conductor) ~ 2 ma (2 wire type) Select Compensated/ non-compensated Instantaneous flow (Note: Compensation can be selected if the temperature compensation function is available). ~ s (Set at intervals of.s) 1 km or less (For 1.2 mm 2 Cable Conductor), 2 km or less (For 2 mm 2 Cable Conductor) Smart Communication (When selected wire type Open Drain or 2 wire type Analogue Output only) DC 2 V ±1% (When Open Drain or Voltage Pulse, DC 12 V ± 1% can be used) 28 ma or less Compensated / Non-compensated Integrated Value Set the push button on the display panel or via communication protocol. IP Explosion-Proof Construction(ExdⅡT) -1 ~ (Storage Temperature Range: -2 ~ ) ~ 9% RH Note) 1.* marked item is option. 2. Pulse output and analogue output cannot be done at the same time. LCD Display 8 digits Select between compensation and non-compensation. (Note: Compensation can be selected if the temperature compensation function is available) Unit: L, m, kl Maximum 7 digits, Unit: /min, /h Maximum digits (If temperature input is available) Indicates Display Mode or Test Mode Displays Number of Occurrences and Elapsed Time of Alarm Selection by Use of Magnet Approximate Compensation of -line sections( Points) (up to 1-line Sections as an option) Range of Compensation: - ~ 1 Temperature Input: Resistance Temperature Sensor(Pt1,Specified Current:2mA) The Temperature span of the resistance temperature sensor can be adjusted.compensation by JIS K 229 Petroleum or General Quadratic Expression Set the Constant number of the flowmeter between.1 and
5 Pressure Loss Characteristic Capacity Model Pressure Loss (MPa) Flow Rate (m /h) Note) This diagram indicates the case of water at Specific Gravity: 1., Viscosity: 1.mm 2 /s. P Viscosity(mPa s 1/ Specific Gravity / P(Water) Standard Unit of Receiver Standard Unit of Intelligent Counting Unit Capacity Model Receiver Coefficient Correction Output Unit : L/P Totalizing Meter Standard Unit : L Capacity Model Totalizing Meter Standard Unit : kl Intelligent Counting Portion Momentary Flow Rate Specified Unit : kl/h Coefficient Correction Output Unit : L/P ().1 1 ().1 1 8(7).1 1 1(8).1 1 (9).1 1 (1).1 1 7(11).1 1 (12).1 1 2(1).1 1 (1) 1 1 7(1) 1 1 8(17) 1 1 (18) 1 1, (19) 1 1, (2) 1 1, Note) Figure in the ( ) of capacity model shows the former model code. () 1 (L) 1 (L/h).1 () 1 (L) 1 (L/h).1 8(7) 1 (L) 1 (L/h).1 1(8) 1 (L) 1 (L/h).1 (9) (1) (11) (12) (1) (1) (1) (17) (18) (19) (2) Note) Figure in the ( ) of capacity model shows the former model code. --
6 asic Model without Intelligent Counting Unit Contents F P L Potter Meter / ( 2mm) 8 1 ( 2mm) 2 ( mm) 8 ( mm) Conn. 1 ( 1mm) Size. 1 ( 1mm) 2 8 ( 2mm) 2 1 ( 2mm) 12 ( mm) 1 ( mm) Intermittent Maximum Flow Rate (connection) 2.7 m /h ( 2mm). m /h ( 2mm) 8 8 m /h ( 2mm) 1 18 m /h ( 2mm) 2 m /h ( mm) m /h ( mm) Capacity Model 7 72 m /h ( mm) 11 m /h ( mm) 2 1 m /h (, 1mm) m /h ( 1mm) 7 m /h ( 1mm) 8 82 m /h ( 2mm) 1 m /h ( 2mm) 22 m /h ( mm) m /h ( mm) Max.Working Press. Hydraulic Test Pressure Applicable Flange Standard MPa MPa J I S ASME JPI K Pressure D F.1. 2 K G.9 7. Housing lade Object to be applied Material P P SUS1 Standard for the Model or below SUS P SUS For the Model 7 or more Always use - (Hyphen) Structure Fluid Temperature A Integrated Model -1~ Transmitter -1 or below C Separated Model or more Type Fluid Temperature lade Material A For Norm. Temp. -2 ~1 Pickup Coil Reluctance For High Temp. 1 or more Magnetism SUS1 Coil SUS C For Low Temp. -2 or below Applied Fluid Type Capacity Model Temperature Power Explosion Proof Preamplifier M A Standard Type ~ Type 1 or below ExdⅡT 12V DC Separated Model 1 or more : d2g) N A Highly Sensitive Type ~ Type O X Non-frequency Multiplication Type ~ Type P X Frequency Multiplication Type ~ Type -1~ 2V DC ExdⅡT - Always use - (Hyphen) L Extension for Low Temperature (-2 or less) Extension H Extension for High Temperature ( or more) X None Note) For maximum pressure in use : 22 or less for JIS, and 8 or less for ASME-ANSI --
7 asic Model with Intelligent Counting Unit F P L Conn. Size. Capacity Model Pressure Material Counting Unit Extension D F G P P P - S A Y Note) For maximum pressure in use : 22 or less for JIS, and 8 or less for ASME-ANSI A - Max.Working Press. MPa Contents Meter for General Use / ( 2mm) 1 ( 2mm) 2 ( mm) ( mm) ( 1mm) ( 1mm) 8 ( 2mm) 1 ( 2mm) 12 ( mm) 1 ( mm) 2.7 m /h ( 2mm). m /h ( 2mm) 8 m /h ( 2mm) 18 m /h ( 2mm) 2 m /h ( mm) m /h ( mm) 72 m /h ( mm) 11 m /h ( mm) 1 m /h (, 1mm) m /h ( 1mm) m /h ( 1mm) 82 m /h ( 2mm) 1 m /h ( 2mm) 22 m /h ( mm) m /h ( mm) Hydraulic Test Pressure MPa Applicable Flange Standard JIS ASME JPI K K.9 7. Housing lade Object to be applied SUS SUS1 Standard for Type or less SUS Standard for Type 7 or more Always use - (Hyphen) Intelligent Counting Unit Always use - (Hyphen) X None Example of Instrumentation Resistance ulb Quantitative Signal Explosion Proof Preset Counter all Valve Resistance ulb Flow Converter Analog Signal Pulse Signal ~2 A 1~ V Open Collector -7-
8 Dimension Drawing For Power & Signal Model Code Conn.Size. (mm) L Dimension (mm) H φd Approx. Weight (kg) (Approximate) FPL FPL 8 FPL FPL FPL FPL FPL FPL FPL FPL FPL FPL FPL 28 2 FPL FPL FPL Note) This table is for ASME JPI 1 Flange. However, the Dimension L is the same as JIS 2K, ASME JPI. Dimension Drawing H (Approximate) L Intelligent Counting Portion G1/2 For Power & Signal G1/2 For Temperature Measuring Resistor φd Model Code Dimension (mm) Approx. Conn.Size. Weight (mm) L H φd (kg) FPL FPL FPL FPL FPL FPL FPL FPL FPL FPL FPL FPL FPL FPL FPL FPL Note) This table is for ASME JPI 1 Flange. However, the Dimension L is the same as JIS 2K, ASME JPI. -8-
9 Accessories Straightener Overview The straightener has multiple flow straightening fine tubes inside the main body. In order to keep the accuracy stable, the straightener shall be installed on the upstream side of the turbine meter. Pressure Loss Characteristic Conn.Size. Pressure Loss (MPa) Flow Rate (m /h) Note) This diagram indicates the case of water at Specific Gravity: 1., Viscosity: 1.mm 2 /s. P Viscosity(mPa s 1/ Specific Gravity / P(Water) -9-
10 asic Model F L S 8 8 Conn. Size Pressure Material D F G P P P Max.Working Press. MPa Housing Contents Straightener / STPG 7(Standard) SUS (2mm) (2mm) (mm) (mm) (1mm) (1mm) (2mm) (2mm) (mm) (mm) Applicable Flange Standards J I S 1 K 2 K ASME JPI 1 Rectifying Pipe SUS Note) For maximum pressure in use : 22 or less for JIS, and 8 or less for ASME-ANSI Dimension Drawing Conn.Size. (mm) Dimension (mm) L φd Approx.Wight (kg) Note) This table is for ASME JPI 1 Flange. However, the Dimension L is the same as JIS 2K, ASME JPI. -1-
11 Cautions for Use (1) Caution for Flowmeter Piping Installation Example of Standard Piping (According to JIS Z87) Strainer Straightener 2D or more If the fluid temperature is -1 less or more, please separate the Pickup and Preamplifier.(Please remind that the wire length between Pickup and Preamplifier shall be m or less.) Pickup Flow Direction No Extension (For low & high temp.) Preamplifier (2) Caution for Wiring Potter Meter D or more D : Meter Connection Size Pickup Preamplifier With Extension (For low & high temp.) Heat Insulation Section (Heating/Cooling) Wiring must be used 2 wick shield line. The relation between the thickness and the transmission distance of the wick wire is shown in the table below. Core Cross Section Area Transmission Distance.9 mm km and less 1.2 mm 2 1.2~1. km 2. mm 2 1.~2. km Please install straight tubes upstream and the downstream of turbine meter like left drawing to correctly reproduce the accuracy at the time of calibration. And, please set up the straightener in turbine meter. Please set up the detection edges such as thermometer and pressure gauges (Well) from meter exit to the downstream sides of D or more. And, adjust the flow on the downstream sides of the meter. Please use a concentric reducer when you install reducer at the entrance of the meter. For the evaporation prevention of the fluid,please maintain the value which satisfies the following expression in fluid pressure P on the meter exit side. P 2 P+1.2Pv (According to API MPMS.) P : Pressure Loss of meter in the maximum flow rate Pv: Steam pressure of fluid at maximum working temperature Please avoid the installation in the following places to prevent a turbulence and secure a normal signal because turbine meter detects a minute flow signal. Please separate as a standard by 1 m or more. 1 High voltage or high current source and the vicinity of that wiring 2 Place of magnetic field The Turbine meter shall be placed where the vibration is as little as possible. If large vibration is existed, the flow rate is detected in error even there is no state of flow (Output of pulsation in error) Please ground the earth by one point on the receiver side. Wiring must not coexist with the electric wire tube etc. of the same position duct as power line of 1 V AC or more.please separate by 1 m or more when adjoining concurrently even in the case of an different duct. Ordering Instructions Item Applications Applicable Fluid Name Accuracy Flow Rate Operating Temperature Operating Pressure Viscosity and Specific Gravity Connection Standard Flow Direction Counting Unit Sending Unit Applied Regulations Attached Equipment Power Supply Contents To classify the usage in the Process Control, Trading, Receiving or Shipment etc. Name, Composition, With or without contaminant ±.2, ±. Maximum, Normal, Minimum (Time of Use For Each Day) (L/h or m /h) Maximum, Normal, Minimum ( ) Maximum, Normal, Minimum (MPa) Viscosity (at ), Specific Gravity (at ) Connection Size and Flange Standard, etc. From the Right to the Left / From the Left to the Right Unit of Counter Unit of the Output Pulse Name of Regulation and Standards Necessity of the Strainer, Straightener or Valve etc. (for the Intelligent Counting Unit) (for the Intelligent Counting Unit) (L) (L/P)
DELTA FLOWMETER FOR GAS SERVICE (INSERTION TYPE) MODEL VF SERIES
DETA FOWMETER FOR GAS SERVICE (INSERTION TYPE) MODE VF SERIES GENERA SPECIFICATION GS. No. GBD0-0-E GENERA In the thermistor type Delta meter, a probe inserted in the pipeline detects the representative
More informationULTRA OVAL Meter Sizes:39, 41, 45, 50, 52, 53 w/unfactored Pulse Generator (NPG60A)
ULTRA OVAL Meter Sizes:9, 4, 45, 50, 5, 5 w/unfactored Pulse Generator (NPG60A) GENERAL SPECIFICATION GS.No.GBU0--E GENERAL ULTRA OVAL MODEL 9, 4, and45 provides extensive capability as a highly dependable
More informationElectromagnetic Flowmeter
Overview Flokal B.V. smart electromagnetic flow meter is hallmarked by its high performance and reliability that are based on successful, field-proven technology. It s being widely used in industries such
More informationFitting PS P - B - R2
INTERNAL STRUCTURE PS86 (G 3/8) 2 3 FEATURES Solidstate pressure switch with no mechanical moving parts Isolated output via a photo-coupler Switching pressure adjustable and hysteresis band adjustable
More informationCoriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM
MAXIFO TM Features MaxiFlo Coriolis Mass Flowmeter series MCM is a mass flow meter that measures mass flow, density and temperature of liquids, slurries and gases. And it even measures oil content in water.
More informationSECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:
SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine
More informationIntegral V-Cone Flowmeter VD series
TRANSMITTER DIRECTLY MOUNTED! SIMPLE AND EASY INSTALLATION Integral V-Cone Flowmeter VD series OUTLINE VD series Integral V-Cone Flowmeter is a differential pressure type flowmeter. Unlikely to existing
More informationPG-200/PG-208 PRESSURE GAUGES P G G P P
Digital 3 1/2 digits monitor Set button for switch output HI or LO (PG-200) (PG-208) Digital 3 1/2 digits Power switch LO setting VR for switch output LO HI setting VR for switch output HI SPAN adjustment
More informationMX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E
OMPT ND USER FRIENDLY MX Series Metal Tube Type Variable rea Flowmeter OUTLINE MX Series flowmeter is the metal tube type variable area flowmeter having the unified face-to-face dimension. The compact
More informationAM-1000 Series COMPACT FLOWMETER
METAL TUBE VARIABLE AREA FLOWMETER AM0 Series COMPACT FLOWMETER GENERAL AM0 series are most well accepted metal tube flowmeters which have been developed based on the long time experience of TOKYO KEISO
More informationPressure transmitters for industrial applications MBS 32 and MBS 33
Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer
More informationMODEL : TX Series (Nom. sizes 15mm to 400mm)
iquid High performance and wide viscosity range EX TURBINE MODE : TX Series (Nom. sizes 15mm to 4mm) GENERA EX TURBINE is an industrial turbine meter for consistent and accurate liquid flow measurement.
More informationBy-Pass. This voltage is proportional to the liquid level (threewire potentiometer circuit). The resistance reading can
" " ' " ' / The magnetic field which is in the ball or cylindrical floats actuates very small reed contacts through the wall of a guide tube and these pick up an uninterrupted measuring-circuit voltage
More informationMODEL: CR002, CR003, CR004. ADC12 Display shield. Liquid (Density range: 0.3 to 2.0g/mL) Operating temperature range
Liquid Inexpensive Microflow Coriolis Flowmeter CoriMate Ⅱ MODEL: CR002, CR003, CR004 GENERAL Based on the knowledge and experience on Coriolis technologies OVAL has gained over many years, the Corimate
More informationAM-1000 Series COMPACT FLOWMETER
METAL TUBE VARIABLE AREA FLOWMETER AM0 Series COMPACT FLOWMETER GENERAL AM0 series are most well accepted metal tube flowmeters which have been developed based on the long time experience of TOKYO KEISO
More informationED 701 General Industry Pressure Transmitter
ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationPressure. 1 Fitting PA R - N R2
INTERNAL STRUCTURE (R 1/4) 4 1 2 3 FEATURES High corrosion resistance and drip-proof construction port attachment made of Proven IP-65 grade gauge body (IP-65 in accordance with IEC) Standard product provides
More informationVORTEX FLOWMETER (DELTA FLOWPET)
VORTEX FOWMETER (DETA FOWPET) DATA SHEET FMR, M This instrument is a Karman vortex flowmeter capable of measuring the flow rate of liquid, gas, and vapor. The heavyduty detecting section made of stainless
More informationTurbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas
Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement
More informationFLOW MEASUREMENT. INC 102 Fundamental of Instrumentation and Process Control 2/2560
FLOW MEASUREMENT INC 102 Fundamental of Instrumentation and Process Control 2/2560 TABLE OF CONTENTS A. INTRODUCTION B. LOCAL FLOW MEASUREMENT B.1 Particle Image Velocimetry (PIV) B.2 Laser doppler anemometry
More informationPTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30
eries Features Best pressure transmission solution for small and middle sized project such as indoor heating and air conditioning, water and sewer, or incinerator, etc. Improves noise resistance and minimize
More informationK Series SIGHT GLASS FOR CONVENIENT OBSERVATION OF LIQUID FLOW GENERAL
FOR CONVENIENT OBSERVATION OF IQUID FOW K Series SIGHT GASS GENERA K series are sight glasses for observation of various liquids. Different types are available to meet applications and requirements. Cast
More informationPressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27
Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for
More informationDOG-1/-3. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air : 120 C. p max. : PN 40; t max
Oscillation Flowmeter for gases measuring monitoring analysing DOG1/3 Measuring ranges: 0.2 20... 200 20000 m 3 /h air p max : PN 40; t max : 120 C Connection: flange DN 25... DN 400 Material: cast iron,
More informationE6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders
Multi-turn High-precision Encoder Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders Reset function for easy origin alignment when built-into equipment. Multi-turn
More informationPAA-ANALYZERS PRINCIPLE OF OPERATION
PAA-ANALYZERS PRINCIPLE OF OPERATION The PAA process analyzer comprises a control unit and an analyzing section which includes the reaction chamber and measuring cell, reagent pumps and associated valves
More informationOPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820
Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820 Your purchase of this PEN VIBRATION METER marks a step forward for you into the field of precision measurement.
More informationPressure Transmitter ED 701
Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation
More information( Single Case Construction )
OVL FLOWMETER Meter Size:,,,, ( Single ase onstruction ) Pocketless Design GENERL SPEIFITION GS.No.GBB--E GENERL The OVL flowmeter is a positive displacement type flowmeter comprising a pair of oval gear
More informationPro-V Multivariable Flowmeter Model M22 In-line Vortex
Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,
More informationUltrasonic Gas Flow Meter
P r o d u c t i n f o r m at i o n FLOWSIC600 Ultrasonic Gas Flow Meter For custody transfer and process applications Analyzers and Process Instrumentation FLOWSIC600 For Custody Transfer and Process Applications
More informationCORIOLIS MASS FLOW METERS FOR GAS AND LIQUID MEASUREMENT. Michael Keilty (Presented by Hubbard Donald) Endress + Hauser Flowtec AG
Introduction CORIOLIS MASS FLOW METERS FOR GAS AND LIQUID MEASUREMENT Michael Keilty (Presented by Hubbard Donald) Endress + Hauser Flowtec AG A mass flowmeter is a system that provides a measurement of
More informationDS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.
DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link
More information24 volts (0.25 amps current-limited)
Question 1 Questions Suppose the lamp refuses to light up. A voltmeter registers 24 volts between test points C and D: A C E + 24 volts (0.25 amps current-limited) B D F First, list all the possible (single)
More informationPG-100 HANDY MANOMETER COPAL ELECTRONICS FEATURES MODEL NUMBER DESIGNATION P G G P. marking Compatible with EMC directive
HANDY MANOMETER Power button Hold button marking Compatible with EMC directive Digital 3 1/2 digits Zero adjustment VR FEATURES Excellent stability State of the art sensor and circuit technology guarantees
More informationCTC 155 / 350 / 660 Dry-block calibrator
CTC 155 / 350 / 660 Dry-block calibrator Wide temperature range: CTC-155: -25 to 155 C CTC-350: 28 to 350 C CTC-660: 28 to 660 C Fast calibration External reference sensor External sensor control Easy
More information473 Dew Point Hygrometer
gh Performance Chilled Hygrometer With Cable Mounted Measuring Heads ghly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct insertion
More informationDirect-operated 2/2-way solenoid valves Type EV210B
Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance
More information473 Dew Point Hygrometer
High Performance Chilled Mirror Hygrometer With Cable Mounted Measuring Heads Highly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct
More informationPHOENIX CONTACT - 04/2016. Features
Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.
More informationDS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm
Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar
More informationv = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes
Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes Examples of Application Flow measurements also in hazardous locations X zone 0 or zone 1 in clean rooms in air
More informationTF-1000 Series MINI THERMAL MASS FLOWMETER PERFECT LINE-UP, BEST COST PERFORMANCE OUTLOOK FEATURES OPERATION PRINCIPLE PRODUCT LINE-UP
PERECT INE-UP, EST COST PERORMNCE T-000 Series MINI TERM MSS OWMETER OUTOOK T-000 MINI TERM MSS OWMETERS are designed and developed to offer the remote indication and control of gas flow process where
More informationPro-V Multivariable Flowmeter Model M23 Insertion Vortex
Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,
More informationCone differential pressure flow meter. Operating manual WIDE PLUS PRECISION INSTRUMENTS CO., LTD.
Cone differential pressure flow meter Operating manual WIDE PLUS PRECISION INSTRUMENTS CO., LTD. INDEX Introduction 2 Principle Application The characteristics of flow meter Specification Technical features
More informationControl Engineering BDA30703
Control Engineering BDA30703 Lecture 4: Transducers Prepared by: Ramhuzaini bin Abd. Rahman Expected Outcomes At the end of this lecture, students should be able to; 1) Explain a basic measurement system.
More informationOPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820
Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820 Your purchase of this PEN VIBRATION METER marks a step forward for you into the field of precision measurement.
More informationCooling Water Flow Regulator
Temperature controlled, indirectly and directly actuated diaphragm valves / seat valves Port size G 3/8 to G DN 0 to DN 0 ontinuous regulation High accuracy No auxiliary energy required Technical data
More informationTransmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level
Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level
More informationCOURSE OF Prepared By: MUHAMMAD MOEEN SULTAN Department of Mechanical Engineering UET Lahore, KSK Campus
COURSE OF Active and passive instruments Null-type and deflection-type instruments Analogue and digital instruments In active instruments, the external power source is usually required to produce an output
More informationOperating Instructions for Digital Manometer. Model: MAN-SD
Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5
More informationCOMPACT FLOWMETER TO COVER ALL POSSIBLE APPLICATIONS. METAL TUBE AM-1000 Series GENERAL FEATURES TG-F962-0E APR.,2000 AM-1000 COMPACT FLOWMETER
AM0 TO COVER ALL POSSIBLE APPLICATIONS METAL TUBE AM0 Series GENERAL AM0 series are most well accepted metal tube flowmeters which have been developed based on the long time experience of TOKYO KEISO in
More informationv = 00,20 m/s Thermal Flow Sensors TA with thin-film sensor element Probes Probe guides Measuring tubes
with thin-film sensor element Probes Probe guides Measuring tubes Examples of Application Flow measurements also in hazardous locations Ex zone 0 or zone 1 in clean rooms in air conditioning and ventilating
More informationTarget Insertion Flowmeter
Principle of Operation Flow is measured in terms of dynamic force acting on a target (solid disk) in the flow stream. Hermetically sealed, bonded strain gages in a bridge circuit configuration mounted
More informationE8EB-N0C2B E8EB-N0B2B
Slim Sensor CSM DS_E 1 Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree
More informationTHM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist
THM80X Series Feature Application IP67 protection degree, rugged aluminum case, fit in variety harsh environment Capable of temperature compensation Linear adjustment temperature & humidity by computer,
More informationMetso Concentration Measurement 3300
Metso Concentration Measurement 3300 Metso Concentration 3300 Accurate direct in-line measurement The Concentration Measurement is provided with intelligent technology calculating the concentration of
More informationFull Metal Variable Area Flow Meter and Counter
Full Metal Variable rea Flow Meter and Counter for horizontal and vertical mounting measuring monitoring analysing Special versions up to 600 bar Measuring range: 10-100...00-000 L/h water 0.3-3.0...-0
More informationRequest Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.
Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -A - Introduction - Thank for your purchasing MITSUBISHI ELECTRIC MELPRO TM D Series Digital Protection
More informationST3000 Series 900 Smart Transmitter Differential Pressure Transmitters
No. SS2-STJ100-0100 (Rev.9) ST3000 Series 900 Smart Transmitter Differential Pressure Transmitters Model STD910/STD920/STD930/STD960/STD921/STD931/STD961 OVERVIEW The ST3000 Smart Transmitter is a microprocessor-based
More informationDirect-operated 2/2-way compact solenoid valves Type EV210A
Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together
More informationIndustrial Pressure Transmitter
ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter
More informationVolumetric Flow Measurement
Volumetric Flow Measurement TVF Series Vortex Flow Meter Xi an Tosilon Automation Co., Ltd No.299, Daqing Rd, Lianhu District, Xi'an Shaanxi, China Tel: +86-29-8823 8550 info@tosilon.com; www.tosilon.com
More informationStandard Practices for Air Speed Calibration Testing
Standard Practices for Air Speed Calibration Testing Rachael V. Coquilla Bryza Wind Lab, Fairfield, California Air speed calibration is a test process where the output from a wind measuring instrument
More informationType UB1 Load Cell. Option Stainless steel cable gland
Type UB1 Load Cell IP68 APPROVED Product Description Type UB1 is a stainless steel universal load cell which allows for tension and compression loading. Its complete hermetic sealing makes it suitable
More informationHD2016. [ GB ] Weighing rain gauge. Rain PART OF G H M GROUP TELEMETRIE & AUTOMATION TELEMETRIE & AUTOMATION
HD2016 [ GB ] Weighing rain gauge Rain PART OF G H M GROUP TELEMETRIE & AUTOMATION TELEMETRIE & AUTOMATION [ GB ] HD2016 Weighing rain gauge [ GB ] HD2016 is a rain gauge that detects the weight of the
More informationAcceleration/Velocity/Displacement VIBRATION METER
Acceleration/Velocity/Displacement VIBRATION METER Model : VB-8220 Your purchase of this VIBRATION METER marks a step forward for you into the field of precision measurement. Although this METER is a complex
More informationProximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C
ASH & ALAIN INDIA PVT LTD S-00, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-000(India) Tel : 0-797575 Fax : 0-79757 E-mail : sales@ashalain.com Proximity Ideal for High Temperatures and Cleaning
More informationRelative pressure transmitter type 520
Relative pressure transmitter type 520 Pressure range The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the pressure measuring cell is fully
More informationOscillation Flow Meter for Gases
Oscillation Flow Meter for Gases measuring monitoring analysing Measuring ranges: 0.2 to 000 m 3 /h air pmax: PN 0, tmax: 0 C Connection: flange DN 25 DN 00 : Cast Iron, steel or stainless steel Accuracy:
More informationAcceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202
Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202 Your purchase of this VIBRATION METER marks a step forward for you into the field of precision measurement. Although this METER is
More informationSolenoid valves 2/2-way direct-operated type EV210A
MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valves 2/2-way direct-operated type EV210A EV210A covers a wide range of small, direct-operated 2/2-way solenoid valves for use in industrial machinery.
More informationWISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS
Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS Variable or constant flow regulation or constant pressure regulation Wireless communication via radio Integrated sensor
More informationSITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181
Siemens AG 09 SITRANS F flowmeters System information Overview Siemens offers two types of ultrasonic flowmeters, in-line flowmeters and clamp-on flowmeters. This offers the end user the maximum flexibility
More informationThe Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:
The basic PC software is supplied free with the recorder. There is an additional charge for the extensive Data Acquisition Software supplied with communication of RS-232/422/485 or Ethernet. The Ordering
More informationDMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output
More informationSolar Flat Plate Thermal Collector
Solar Flat Plate Thermal Collector INTRODUCTION: Solar heater is one of the simplest and basic technologies in the solar energy field. Collector is the heart of any solar heating system. It absorbs and
More informationTF-1000 Series MINI THERMAL MASS FLOWMETER PERFECT LINE-UP, BEST COST PERFORMANCE OUTLOOK FEATURES OPERATION PRINCIPLE PRODUCT LINE-UP
PERFET INE-UP, EST OST PERFORMANE TF-000 Series MINI TERMA MASS FOWMETER OUTOOK TF-000 MINI TERMA MASS FOWMETERS are designed and developed to offer the remote indication and control of gas flow process
More informationDual laser + type K thermometer INFRARED THERMOMETER
Dual laser + type K thermometer INFRARED THERMOMETER Model : ATE-2509 Your purchase of this INFRARED THERMOMETER marks a step forward for you into the field of precision measurement. Although this METER
More informationDUBLIN INSTITUTE OF TECHNOLOGY Kevin Street, Dublin 8.
Question Sheet Page 1 of 5 Instructions for the student: Question 1 is compulsory [40 marks] Attempt any two other questions [30 marks per question] The following must be made available during the examination:
More informationApplied Fluid Mechanics
Applied Fluid Mechanics 1. The Nature of Fluid and the Study of Fluid Mechanics 2. Viscosity of Fluid 3. Pressure Measurement 4. Forces Due to Static Fluid 5. Buoyancy and Stability 6. Flow of Fluid and
More informationApplied Fluid Mechanics
Applied Fluid Mechanics 1. The Nature of Fluid and the Study of Fluid Mechanics 2. Viscosity of Fluid 3. Pressure Measurement 4. Forces Due to Static Fluid 5. Buoyancy and Stability 6. Flow of Fluid and
More informationMIK. Electromagnetic Flowmeter Compact. for conductivity liquids. Range from liquids, acids and caustic solutions:
Electromagnetic Flowmeter Compact for conductivity liquids measuring monitoring analysing MIK Range from liquids, acids and caustic solutions: 0.0-0. 3-700 l/min frequency-, switching-, analogue output
More information1. Mark the correct statement(s)
1. Mark the correct statement(s) Figure to the right shows a mass measurement scale using a spring. 1.1 The span of the scale is a) 16 kg b) 21 kg c) 11 kg d) 5-16 kg 1.2 The range of the scale is a) 16
More informationVIBRATION METER Acceleration & Velocity Model : VB-8201HA
VIBRATION METER Acceleration & Velocity Model : VB-8201HA TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS...2 3. FRONT PANEL DESCRIPTION...4 3-1 Display...4 3-2 BNC socket of meter...4 3-3 RMS/PEAK
More informationIndustrial Instrumentation Prof. A. Barua Department of Electrical Engineering Indian Institute of Technology Kharagpur. Lecture - 14 Flowmeter ΙΙΙ
Industrial Instrumentation Prof. A. Barua Department of Electrical Engineering Indian Institute of Technology Kharagpur Lecture - 14 Flowmeter ΙΙΙ Welcome to lesson 14 of Industrial Instrumentation. In
More informationPascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure
DATASHEET Pascal ET Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure - electrical signals (ma, mv, V, ) - temperature (TC and
More informationAn Essential Requirement in CV Based Industrial Appliances.
Measurement of Flow P M V Subbarao Professor Mechanical Engineering Department An Essential Requirement in CV Based Industrial Appliances. Mathematics of Flow Rate The Scalar Product of two vectors, namely
More informationMicrocare LCD Solar MPPT User Documentation
Microcare LCD Solar MPPT User Documentation 1 CONTENTS 1. INTRODUCTION. 3 1.1. General Description 1.2. Key Features 1.3. Important Notices 1.4. Recommended Array Sizes 1.5. MPPT Description 1.6. MPPT
More informationFundamentals of Flow Metering
Technical Data Sheet 00816-0100-3031 Fundamentals of Flow Metering A reliable flow indication is dependent upon the correct measurement of A and V. If, for example, air bubbles are present in the fluid,
More informationAIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control
AIR PREPARATION ELECTRONICALLY CONTROLLED PRESSRE REGLATING ALE (PROPORTIONAL PRESSRE REGLATING ALE) SERIES control Description Abb. Port size Recommended Type Data Sheet No. flow (l/min)* airfit tecno
More informationAmir Hossein Parvardi 1
Instrumentation 1 1 School of Electrical & Computer Engineering University of Tehran (ECE) October 5, 2015 1 / 1 Flowmeters (ECE) October 5, 2015 2 / 1 Flowmeters Types of Flowmeters Types of Flowmeters
More informationLEVEL CONTROLS. Selection Guide. Capacitance Calculations and Data For Selecting Robertshaw Level Control Instruments and Sensing Probes
LEVEL CONTROLS Selection Guide Capacitance Calculations and Data For Selecting Robertshaw Level Control Instruments and Sensing Probes Capacitance Probe Calculations The following data is compiled to assist
More informationOPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000
3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER Model : TM-2000 Your purchase of this THERMOMETER marks a step forward for you into the field of precision measurement. Although this THERMOMETER is a
More informationSTATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016
APPLICATIONS Moisture monitoring of air or gas (SF6) Suitable for indoor or outdoor Industrial, medical or aerospace fields HIGHLIGHTS High voltage circuit breakers commonly used for distribution and transmission
More informationKZPb
---------------------------------------------------------- ---------------------------------------------------------------------- Electronic constant pressure regulator FUNCTION KZP is an electronic pressure
More informationDMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm
DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up
More informationINTERNATIONAL OIML D 25 DOCUMENT. Vortex meters used in measuring systems for fluids ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION
INTERNATIONAL OIML D 25 DOCUMENT Edition 1996 (E) Vortex meters used in measuring systems for fluids Compteurs à vortex utilisés dans les ensembles de mesurage de fluides OIML D 25 Edition 1996 (E) ORGANISATION
More informationAir velocity & IAQ measuring instruments
Data sheet dp Air velocity & IAQ measuring instruments - air velocity & IAQ measuring instrument - dp air velocity & IAQ measuring instrument incl. differential pressure C CO Intuitive: clearly structured
More informationPro-V Multivariable Flowmeter Model M23 Insertion Vortex
Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,
More information