TF-1000 Series MINI THERMAL MASS FLOWMETER PERFECT LINE-UP, BEST COST PERFORMANCE OUTLOOK FEATURES OPERATION PRINCIPLE PRODUCT LINE-UP
|
|
- Jasmin Stevens
- 5 years ago
- Views:
Transcription
1 PERECT INE-UP, EST COST PERORMNCE T-000 Series MINI TERM MSS OWMETER OUTOOK T-000 MINI TERM MSS OWMETERS are designed and developed to offer the remote indication and control of gas flow process where glass tube purgemeters have been commonly used. T-000 MINI TERM MSS OWMETERS are very competitive in price and very compact in size and can be a good substitution for such glass tube purgemeters. New type in the mid to large diameter has been added to T-000 series. Different types of sensors cover all requirements for gas measurement. lso ll-in-one type panel mount convertors are ready for easy loop design. ETURES ow cost, igh performance igh accuracy Direct mass flow measurement using thermal theory ree from changes of pressure and temperature! No compensation required. Quick response 0.5sec. for % Easy maintenance No by-pass tube used. igh durability Newly designed sensing element offers high durability. Supporting instruments are ready. Wide range Min. 0 to /min(nor)., Max. 7m /h(nor). can be covered by one line. The piping layout can be freely made due to the short required straight run. PRODUCT INE-UP Different sensors and panel mount convertors are ready to choose Mass flowmeter ow price, Compact T-00 P Engineering plastic body T-00 S SCS casted body Standard type T- Stainless steel body, Mid to large connection types are available. T- Stainless steel body, ow pressure loss Outdoor use, Water tight housing T- Stainless steel body, Mid to large connection types are available T- Stainless steel body, ow pressure loss T-5 Stainless steel body, With indicator, Mid to large connection types are available Convertor TM-0 low rate, Totalizing, and alarm indication, nalog output, Totalizing pulse output, larm output OPERTION PRINCIPE Temperature detection sensor Ra and velocity detection sensor Rw are installed in the gas flow path of T-000 MINI-TERM MSS OWMETER. The internal electronics circuits keep the temperature gap between Rw (Tw) and Ra (Ta = Gas temp.) constant by supplying electric current I. The transferred heat from Ra to passed gas (Rw I ) is proportional to the mass flow rate of the gas to be measured which can be calculated from supplied corrent I. The detection principle is completely free from the change of gas pressure and the change of temperature. It is compensated by internal software and finally the measurement is totally independent of any operating conditions. The flow rate is calculated from supplied current I and output in the form of electric signal. I Ra Ta Rw Tw O W
2 T-000 SERIES MINI-TERM MSS OW METER STNDRD SPECIICTION ND MODE CODE [up to 000/min(nor)] Model T-00 P/S T- T- Type Compact type Stainless steel body, Standard type Gas to be measured Scale range ll kinds of gases, except gases containing more than 0%(Vol.) of or e and mixture of or e and Cnm Min. 0 to /min(nor) Max. 0 to 0 /min(nor) mb. and Gas temp. 0 to 60 C [0 to C for T-000P (Poly-acethal resin body)] Gas press to.0 MPa ccuracy ±.0%.S. Temp. change effect Within ±0.%.S. / C Press. change effect Within ±0.%.S. /0. MPa Rangeability : 0 Gas contact part material Tube Sensor Seal Stainless steel body, Water tight housing ousing material S resin IP0 equ. (Indoor use) DC IP65 equ. (Water tight) Process connection Power supply/ Output T-00 P : Poly-cethal, P, SUS6 T-00 S : SCS, P, SUS6 T-00 P : Rc/ T-00 S : Rc/ or OD/ SW SUS6[SUS6 and P (T- )] Combination of SUS6, Glass, PT and CTE KM or CR Min. 0 to /min(nor) Max. 0 to 000 /min(nor) T- : Rc/ OD/, /8, / SW 5, 0, 5, JIS0K lange T- : Rc/, /8 OD/, /8, / SW 5, 0, 5, JIS0K lange T- : Rc/8, / OD/8, /, / SW 5, 0, 5, JIS0K lange T- : Rc/8, /, / OD/8, /, / SW 5, 0, 5, JIS0K lange T- 0 ± V DC or ±5 V DC, + m, -0 m/0 to 5 V DC (oad resistance:more than 5kΩ) T- V DC ±0%, +m/ to 0 m DC (oad resistance:ess than Ω) Electric connection T low range /min(nor) up to 0 Power supply/ 0 ± V DC(5V)0 to 5 V DC Output V DC/ to 0 m DC P Poly-cethal ody material S SCS 00 0 to 0 0 to 0 0 to to to 0 Scale range 0 to 5 /min (nor) 0 to to 0 0 to to to 00 0 to 0 P Rc thread rating S Swagelok* size 0/(8) *Swagelok connection is available only for T-00 S type. Exclusive cable with connector T- - - low range /min (nor) Power supply/ 0 Output Scale range /min (nor) rating size P S (Choose the connection size from the above-mentioned process connection.) up to 0 up to up to 0 up to 000 ± V DC(5V)0 to 5 V DC V DC/ to 0 m DC 0 to 0 to 0 to 5 0 to 8 0 to 0 0 to 5 T- 0 to 0 0 to 0 to 0 to 80 0 to 00 0 to 0 0 to 0 to T- 0 to 0 to 0 0 to 00 T- 0 to 0 0 to to 800 T- 0 to 000 Rc thread Swagelok JIS0K lange /(8) /8(0) /(5) /(0) (5) G/, M screw terminal T- - - low range /min (nor) Power supply/ 0 Output Scale range /min (nor) P rating S size (Choose the connection size from the above-mentioned process connection.) up to 0 up to up to 0 up to 000 ± V DC(5V)0 to 5 V DC V DC/ to 0 m DC 0 to 0 to 0 to 5 0 to 8 0 to 0 0 to 5 T- 0 to 0 0 to 0 to 0 to 80 0 to 00 0 to 0 0 to 0 to T- 0 to 0 to 0 0 to 00 T- 0 to 0 0 to to 800 T- 0 to 000 Rc thread Swagelok JIS0K lange /(8) /8(0) /(5) /(0) (5) CO., TD. TG-ES65-7E
3 T-000 SERIES MINI-TERM MSS OW METER T- T- T-5 ow pressure loss, Indoor use ow pressure loss, Water tight type ll kinds of gases, except gases containing more than 0%(Vol.) of or e and mixture of or e and Cnm Min. 0 to /min(nor) Min. 0 to /min(nor) Max. 0 to 000 /min(nor) Max. 0 to 000 /min(nor) 0 to 60 C to.0 MPa ±.0%.S. Within ±0.%.S. / C Within ±0.%.S. /0. MPa : 0 With indicator, Water tight type S resin IP0 equ. (Indoor use) SUS6 T- : Rc/ or 5JIS0K lange T- : Rc/ or 0JIS0K lange T- : Rc or 5JIS0K lange Combination of SUS6, Glass, PT and CTE KM or CR DC IP65 equ. (Water tight) T- 0 ± V DC or ±5 V DC, + m, -0 m/0 to 5 V DC (oad resistance:more than 5kΩ) T- V DC ±0%, + m/ to 0 m DC (oad resistance:ess than Ω) SUS6 [SUS6 and P (T-5)] C IP65 equ. (Water tight) T-5: Rc/, /8, / OD/, /8, / SW 5, 0, 5, JIS0K lange T-5: Rc/, /8, / OD/, /8, / SW 5, 0, 5, JIS0K lange T-5: Rc/8, / OD/8, / SW 5, 0, 5, JIS0K lange T-5: Rc/8, /, / OD/8, /, / SW 5, 0, 5, JIS0K lange 85 to 0 V C, V to 0 m DC (oad resistance:ess than Ω) Exclusive cable with connector T- - - low range /min(nor) Power supply/ 0 Output Scale range 0 /min (nor) rating P size (Choose the connection size from the above-mentioned process connection.) up to up to 0 up to 000 ± V DC(5V) 0 to 5 V DC V DC/ to 0 m DC 0 to 0 to T- 0 to 0 to 0 0 to 00 T- 0 to 0 0 to to 800 T- 0 to 000 Rc thread JIS0K lange 08/(5) /(0) 6 (5) *T- is recommended for scale range smaller than 0/min(nor). *Required straight run for upstream is 5D and downstream is 0D. Installation of the pipe is the same connection of flowmeter. T- low range /min(nor) Power supply/ Output Scale range /min (nor) rating G/, M screw terminal size (Choose the connection size from the above-mentioned process connection.) up to up to 0 up to 000 ± V DC(5V) 0 to 5 V DC V DC/ to 0 m DC 0 to 0 to 0 to 0 to 0 0 to 00 0 to 0 0 to to to 000 P Rc thread JIS0K lange 08/(5) /(0) 6 (5) T- T- T- *T- is recommended for scale range smaller than 0/min(nor). *Required straight run for upstream is 5D and downstream is 0D. Installation of the pipe is the same connection of flowmeter. T-5 - low range /min(nor) Power supply/ Output Scale range /min (nor) rating -G/, M screw terminal size (Choose the connection size from the above-mentioned process connection.) - P S up to 0 up to up to 0 up to to 0 V C/ to 0 m DC 0 to 0 to 0 to 5 0 to 8 0 to 0 0 to 5 0 to 0 0 to 0 to 0 to 80 0 to 00 0 to 0 0 to 0 to 0 to 0 to 0 0 to 00 0 to 0 0 to to to 000 Rc thread Swagelok JIS0K lange /(8) /8(0) /(5) /(0) (5) T-5 T-5 T-5 T-5 TG-ES65-7E CO., TD.
4 OW RTE OW RTE OW RTE OW RTE OW RTE OW RTE T-000 SERIES MINI-TERM MSS OW METER DIMENSION ND WEIGT T-000 Compact type [T-000P.T-000S] Rc screw connection / T-000P pprox.0g T-000S pprox.g MINI-TERM MSS OWMETER T-000 OW MG.No. OW 6 7 SW connection (pprox.g for T-000S) -SW MINI-TERM MSS OWMETER T-000 OW MG.No. OW RTE 6 7 -Md -Md, Rating /SW 0 T-0 Stainless steel body, Standard type [T-0] Rc screw connection (pprox.g) 0 SW connection (pprox.5g) /8SW /SW T- 6mm 8 MINI-TERM MSS OWMETER MINI-TERM MSS OWMETER / MG. NO. OW.5 -SW MG. NO. OW.5, Rating /SW 7 /8SW /SW lange connection (pprox..9kg) MINI-TERM MSS OWMETER MG. NO. OW.5 [Rc, SW and lange connection] Mounting dimension (ottom face) Md 80 [T-0] Rc screw connection (pprox.6g) SW connection (pprox.70g) MINI-TERM MSS OWMETER MINI-TERM MSS OWMETER MG. NO. MG.NO. OW 77 -SW OW 77, Rating /SW /8SW /SW lange connection (pprox..0kg) MINI-TERM MSS OWMETER MG. NO. OW 6 77 [Rc, SW and lange connection] Mounting dimension (ottom face) Md 80 CO., TD. TG-ES65-7E
5 NO. MG.NO. OW RTE OW RTE NO. NO. OW RTE OW RTE NO. NO. OW RTE OW RTE T-000 SERIES MINI-TERM MSS OW METER [T-] Rc screw connection (pprox.kg) SW connection (pprox..kg) MINI-TERM MSS OWMETER MG. OW 8 9 MINI-TERM MSS OWMETER MG. OW 8 9 [lange connection] Mounting dimension (ottom face) 0 7 -Md6 MINI-TERM MSS OWMETER OW MINI-TERM MSS OWMETER MG., Rating -SW OW /8SW 9 /SW 97.5 /SW 06 [Rc and SW connection] Mounting dimension (ottom face) -Md6 5 MINI-TERM MSS OWMETER MG. -SW OW 8, Rating /8SW 68 9 /SW 7 /SW 8 [Rc and SW connection] Mounting dimension (ottom face) -Md6 lange connection (pprox..5kg).5 [T-0] Rc screw connection (pprox..5kg) SW connection (pprox..8kg) lange connection (pprox..kg) MINI-TERM MSS OWMETER MG. OW [lange connection] Mounting dimension (ottom face) 8 9 -Md6 TG-ES65-7E CO., TD. 5
6 OW RTE MSS OWMETER MG. NO. OW OW RTE T-000 SERIES MINI-TERM MSS OW METER T- Stainless steel body, Water tight housing type Rc screw connection SW connection 5 G/ -SW 5 [Rc, SW and lange connection] Mounting dimension (ottom face) C -Md6 Size C Mass (kg) Model / /8 / / /8 / / /8 / /8 / / T- T- T- T- lange connection () Size Rating C Mass (kg) Model JIS 0K (R) () T JIS 0K (R) () JIS 0K (R) () JIS 0K (R) () T- T- T- T-0 ow pressure loss, Indoor use type Rc screw connection lange connection MINI-TERM MSS OWMETER MG.NO. OW MINI-TERM () [Rc, and lange connection] Mounting dimension (ottom face) C -Md6 Size / / Rating Rc connection lange connection JIS0K (R) () C Mass (kg) Model T- T- T-0 T- T- T-0 T- 6mm 6 CO., TD. TG-ES65-7E
7 T-000 SERIES MINI-TERM MSS OW METER T-00 ow pressure loss, Water tight type Rc screw connection lange connection 5 G/ 5 [Rc, and lange connection] Mounting dimension (ottom face) C -Md6 T-0 With indicator, Water tight type Size / / Rating Rc connection C Mass (kg)..8.9 Model T- T- T lange connection JIS0K (R) () T- T- T- Rc screw connection 06 SW connection 86 -G/ -SW [Rc, and connection] Mounting dimension (ottom face) C -Md6 lange connection Size / /8 / / /8 / / /8 / /8 / / C Mass (kg) Model T-5 T-5 T-5 T-5 Size Rating JIS 0K (R) () JIS 0K (R) () JIS 0K (R) () JIS 0K (R) () C Mass (kg) Model T-5 T-5 T-5 T-5 TG-ES65-7E CO., TD. 7
8 T-000 SERIES MINI-TERM MSS OW METER STNDRD SPECIICTION ND MODE CODE [Middle to arge connection type] Model T-5 T-5 T-55 Type Standard type Water tight housing Gas to be measured mb. and Gas temp. Gas press. ccuracy Temp. change effect Press. change effect Gas contact part material Rangeability Tube Sensor Seal ll kinds of gases, except gases containing more than 0%(Vol.) of or e and mixture of or e and Cnm 0 to 60 C to.0 MPa ±.0%.S. Within ±0.%.S./ C Within ±0.%.S. /0. MPa ousing material S resin IP0 equ. (Indoor use) DC IP65 equ. (Water tight) C IP65 equ. (Water tight) Process connection : 0 SUS6 or SUS Combination of SUS6, Glass, PT and CTE (SCS) SUS KM or CR Rc female screw ( to ) JIS0K lange (5 to 80) With indicator, Water tight type Power supply / Output Electric connection T- 0 ± V DC or ±5 V DC, + m, -0 m/0 to 5 V DC (oad resistance: More than 5kΩ) T- V DC ±0%, + m/ to 0 m DC (oad resistance: ess than Ω) 85 to 0 V C, V to 0 m DC (oad resistance: ess than Ω) Exclusive cable with connector G/, M screw terminal -G/, M screw terminal T- - - T- - - T up to 7m /h(nor) up to 7m low /h(nor) up to 7m low /h(nor) low 5 (Refer to the following 5 (Refer to the following 5 (Refer to the following range range range Scale range table.) Scale range table.) Scale range table.) Power supply/ 0 ± V DC(5V) 0 to 5 V DC Power supply/ 0 ± V DC(5V) 0 to 5 V DC Power supply/ 85 to 0 V C/ Output V DC/ to 0 m DC V DC/ to 0 m DC Output Output to 0 m DC Scale range C low rate rating Scale range C low rate rating Scale range C low rate rating SUS (vailable SUS (vailable SUS (vailable only for flange only for flange only for flange Material connection) Material connection) Material connection) SUS6 SUS6 SUS6 6 (vailable for all 6 (vailable for all 6 (vailable for all models) models) models) P Rc thread ( to ) P Rc thread ( to ) P Rc thread ( to ) rating JIS0K lange rating JIS0K lange rating JIS0K lange (5 to 80) (5 to 80) (5 to 80) 5 (5) 5 (5) 5 (5) size -/ () size -/ () size -/ () (Choose the connection size 0-/ from the following ull scale table.) 65-/ 80 *ull scale=() 0 C m /h(nor) (Ex.) m /h(nor) 0 00m /h(nor) 0 7m /h(nor) (0) () (65) (80) (Choose the connection size 0-/ from the following ull scale table.) 65-/ 80 *ull scale=() 0 C m /h(nor) (Ex.) m /h(nor) 0 00m /h(nor) 0 7m /h(nor) (0) () (65) (80) (Choose the connection size 0-/ from the following ull scale table.) 65-/ 80 *ull scale=() 0 C m /h(nor) (Ex.) m /h(nor) 0 00m /h(nor) 0 7m /h(nor) (0) () (65) (80) ull scale according to connection Gas Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. IR N O CO CO r N C C C C m /h(nor) CO., TD. TG-ES65-7E
9 OW RTE OW RTE MSS OWMETER MG. NO. OW OW RTE MSS OWMETER MG. NO. OW RTE OW T-000 SERIES MINI-TERM MSS OW METER T-5 6mm T-5 Standard type Rc screw connection (Rc) Width across flat of joints: 6 (pprox..9kg) Rc screw connection (Rc-/ to Rc) MINI-TERM MSS OWMETER MG.NO. OW (68) () MINI-TERM D 95 Size -/ -/ Rating Rc connection (Width across flat) D Mass (kg) lange connection (5) (pprox..6kg) lange connection ( to 80) MINI-TERM MSS OWMETER MG.NO. OW (68) () MINI-TERM 95 T-5 Water tight housing type Size Rating Mass (kg) lange connection JIS0K (R) () Rc screw connection (Rc) Width across flat of joints: 6 (pprox..kg) G/ 5 G/ Rc screw connection (Rc-/ to Rc) 5 () D () 5 95 Size Rating (Width across flat) D -/ -/ Rc connection Mass (kg)... TG-ES65-7E CO., TD. 9
10 T-000 SERIES MINI-TERM MSS OW METER lange connection (5) (pprox..kg) lange connection ( to 80) () () 95 Size Rating lange connection JIS0K (R) () Mass (kg) T-55 With indicator, Water tight type Rc screw connection (Rc) Width across flat of joints: 6 (pprox..9kg) 06 Rc screw connection (Rc-/ to Rc) 06 () Size -/ -/ Rating Rc connection (Width across flat) D Mass (kg) () () 86 () 86 -G/ -G/ D 5 95 lange connection (5) (pprox..6kg) lange connection ( to 80) 95 Size Rating lange connection JIS0K (R) () Mass (kg) CO., TD. TG-ES65-7E
11 T-000 SERIES MINI-TERM MSS OW METER PRECUTIONS OR INSTTION Required straight run (d: diameter) PRESSURE OSS (The following graphic chart is data in case of air.) Model T-00 P T-00 S T- T- T- T- T-5 T- T- T- T- T-5 T- T- T- T- T- T- T-5 Upstream 5d (*, *) 5d (*, *) 5d (*) 5d (*) Downstream 5d (*, *) 5d (*, *) (*) (*) Press. loss [kpa] T-00 S/00 P/ / /5 Primary pressure TM 0 C 0/min (nor) /min (nor) 0/min (nor) 000/min (nor) T-5 T-5 T T-55 5d (*, *) 5d (*, *) low rate [/min (nor)] (*) The piping different from the diameter of flowmeter is up to ± size. Make the piping after installing the required straight run in the same diameter as the flowmeter. T- / ow press. loss type Primary pressure TM 0 C /min (nor) 0/min (nor) 000/min (nor).5 Press. loss [kpa] (*) Make use of Rc screw fittings less than Sch. 80. (*) Make use of the piping in the same diameter as that of the flowmeter. efore installing the flowmeter onto process piping, flush and clean the whole piping. Install valves downstream if any. Use the shielded cable for wiring and do not locate it near to power supply line etc. to avoid the electric noise. Confirm the arrow mark on the tube which indicates the flow direction. In case of T-5 (With indicator type), the flow direction and configuration are as follows. Specify the flow direction at the time of an order low rate [/min (nor)] T-5 /5 /55 Middle to arge connection type Primary pressure TM 0 C orizontal installation orizontal installation Press. loss [kpa] 5 0 low direction eft to Right low direction Right to eft 5 It is recommended to provide bypass piping for maintenance low rate [m /h (nor)] TG-ES65-7E CO., TD.
12 T-000 SERIES MINI-TERM MSS OW METER TM-0 MINI CONVERTOR UNIT OUTINE TM-0 MINI CONVERTOR UNIT is power supply and indication unit which is used in combination with Tokyo Keiso s T-0, T-000, T- 00, T-6000 and (-) EP-T-00 series MSS OWMETERS. ll necessary functions of power supply to the detectors and scaled flow indication is provided in DIN 7mm compact housing. dditionally, either totalization (with scaled pulse output) of flow or high and low alarm is available for total gas volume management or stable gases supply applications. lso, analog re-output function ( to 0 m DC or 0 to 5 V DC) is provided as standard for further connection to recorders and/or process control loop. STNDRD SPECIICTION OW RTE INDICTION Indication : y digit CD (mm height) ccuracy : ±0.%.S.± last digit additional to detector accuracy nalog re-output (lternative) : a) to 0 m DC Max.load 0Ω : b) 0 to 5 V DC Min.load 00 kω Output accuracy : ±0.%.S. additional to detector accuracy TOTIZTION UNCTION Indication : y 7 digit CD (6mm height) Scaled pulse : Output Open collector Rating V DC, 0 m Max. Pulse width 00 ms (ixed) Pulse rate Equal to counter increments Indication accuracy : ±0.%.S. additional to detector accuracy Scaling factor : 8,000 c/h (Max.) Total re-set : y manual push button or short-circuiting of terminal OW CUT : Standard % (reely programmable) Corresponding function : low rate indication, low rate output, Totalization indication, and Scaled pulse output RM UNCTION larm indication : Red color ED (The light is turned on in operation) larm output : SPST NO (Make contact) or NC (reak contact) (The contact will be opened without power supply.) Contact rating : 5 V C, 0./ V DC, Setting point : points (igh and ow) Setting range : 0 to 00% of span Setting : ield adjustable through front panel key ysteresis width :.0%.S.(ixed) NOG INPUT (lternative) : a) to 0 m DC Input resistance Ω b) 0 to 5 V DC Input resistance kω OTER UNCTION Multi-data : Max.8 different data can be programmed. (Channel selection by front panel key) inearise function (Option) : a) ourth formula multiplier method : b) Extraction of square-root multiplier method Data back up : Total count and operation parameters are memorized by EEROM for 0 years. EXTERN POWER SUPPY : ± V DC, +m, -m OTER SPECIICTION Power supply Power consumption : 5V : 85 to V C /60z Electrical connection : Pin terminal mbient temp : 0 to C (To be free from condensation) Withstand voltage : Power supply to Earth terminal 0 V C, min. Insulation resistance : Power supply to Earth terminal More than 0MΩ (0 V DC) Construction ousing material Weight MODE CODE TM - nalog Input nalog Output larm Output Input & Output characteristics Standard Option Option : Indoor use (IP0 equ.) : S resin containing glass fiber : pprox.g R to 0 m DC 0 to 5 V DC to 0 m DC 0 to 5 V DC : NO, : NO : igh : NC, : NC : ow : NO, : NC NO : Make contact : NC, : NO NC : reak contact inear ourth formula multiplier method Extraction of square-root multiplier method PPICE OWMETERS ND EXCUSIVE CE pplicable flowmeters T-0/000/00/0 T-/00 T-/60 M-000/00 (Option) Cable code SC-MM SC-M SC-M SC-M Cable length m : Standard 00m (Max.) CO., TD. TG-ES65-7E
13 T-000 SERIES MINI-TERM MSS OW METER DIMENSIONS PNE CUT ND MOUNT DISTNCE More than TM-0 CONVERTOR More than 00 Note) Recommending mount panel in to 5mm thickness. RONT PNE TERMIN igh alarm TM-0 CONVERTOR UNIT:(nor) Indication Upper : low rate ower : Totalization ow alarm I /h m /h /min Unit m O MODE PUSE OUT NOG OUT DC POWER TO METER NOG IN Up Down Shift NO WIRING (C) (E) RESET 5 (+) (-) +V COM -V (+) to 0 m DC 0 to 5 V DC IG RM 6 7 OW RM 8.G. 9 0 (-) to 0 m DC 0 to 5 V DC POWER MODE Mode NO NC NO NC to V C WIRING No. Non - use (C) Pulse (E) Output No. Non - use Reset Cable wiring when mass flow meter is used and model change is made from TM-000 to TM-0 should cut the cable of the connector socket part inserted in a converter, and strip cable coating about 7mm and carry out connection as follows (+) nalog ( ) Output (+V) (COM) DC power to meter igh alarm output ow alarm output V COM -V (+) (-) Red Green Yellow White lack ( V) (+) nalog ( ) Input G. C power supply Detector Exclusive cable TG-ES65-7E CO., TD.
14 T-000 SERIES MINI-TERM MSS OW METER PPICTIONS or 0 to 5 V DC Output version In case standard power supply unit is used; In case TM-0 series converter unit is used; T-000P, T-000S, T- 0, T- 0 T-000P, T-000S, T- 0, T- 0 SC-MC cable SC-MM cable ± V DC or ±5 V DC 0 to 5 V DC To control loop T-000 Power supply T-000 5C cable 0 to 5 V DC To control loop T- 0, T- 0 SC-M cable nalog output Scaled pulse output and alarm output ± V DC or ±5 V DC Power supply TM- C or cable with exclusive connector, to 0 m DC Output version or M screw terminal, to 0 m DC Output version T-00P, T-00S, T-, T- T-, T- SC-MP cable C cable to 0 m DC To control loop to 0 m DC To control loop T-00 Power supply V DC Power supply V DC or T5 series (With indicator) version C cable to 0 m DC To control loop nalog output 999 Scaled pulse output CE TERMIN Y TE SIDE O DETECTOR SC-MP Red Green White lack C 0.mm 5.6 C TM- and alarm output C SC-MM. 5.8 Red Green Yellow White 5 lack 5C 0.mm 6 SC-M Power supply Output signal of flow rate (0 to 5 V DC) +V COM -V + - Red Green Yellow White 5 lack 5C 0.mm 6 CO., TD. TG-ES65-7E
15 T-000 SERIES MINI-TERM MSS OW METER OREDRING INORMTION Specify the following for order /inquiry MINI-TERM MSS OW METER Model Gas to be measured Pressure Temperature ull scale size type low direction (T-5 ) T- - - Max. Nor. Min. MPa kpa Max. Nor. Min. C /h (nor) /min (nor) m /h (nor) / (8) /8 (0) / (5) / (0) (5) -/ () -/ (0) () (65) (80) Rc thread Swagelok JIS0K lange VCR (Option) eft to Right Right to eft SUPPORTING INSTRUMENTS Mini converter Exclusive cable TM- SC-MM SC-M * Specification is subject to change without notice. ead Office : Shiba Toho uilding, 7 Shibakoen, Minato-ku, Tokyo Tel : (KEY) ; ax : overseas.sales@tokyokeiso.co.jp ; UR : TG-ES65-7E CO., TD. 5
TF-1000 Series MINI THERMAL MASS FLOWMETER PERFECT LINE-UP, BEST COST PERFORMANCE OUTLOOK FEATURES OPERATION PRINCIPLE PRODUCT LINE-UP
PERFET INE-UP, EST OST PERFORMANE TF-000 Series MINI TERMA MASS FOWMETER OUTOOK TF-000 MINI TERMA MASS FOWMETERS are designed and developed to offer the remote indication and control of gas flow process
More informationIntegral V-Cone Flowmeter VD series
TRANSMITTER DIRECTLY MOUNTED! SIMPLE AND EASY INSTALLATION Integral V-Cone Flowmeter VD series OUTLINE VD series Integral V-Cone Flowmeter is a differential pressure type flowmeter. Unlikely to existing
More informationMX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E
OMPT ND USER FRIENDLY MX Series Metal Tube Type Variable rea Flowmeter OUTLINE MX Series flowmeter is the metal tube type variable area flowmeter having the unified face-to-face dimension. The compact
More informationK Series SIGHT GLASS FOR CONVENIENT OBSERVATION OF LIQUID FLOW GENERAL
FOR CONVENIENT OBSERVATION OF IQUID FOW K Series SIGHT GASS GENERA K series are sight glasses for observation of various liquids. Different types are available to meet applications and requirements. Cast
More informationAM7000 Series GENERAL FEATURES METAL TUBE VARIABLE AREA FLOWMETER
MET TUBE VRIBE RE FOWMETER M000 Series GENER The metal tube variable area flowmeter M000 Series has been developed from M-0 Series which were based on the long time experience of TOKYO KEISO in the field
More informationAM-1000 Series COMPACT FLOWMETER
METAL TUBE VARIABLE AREA FLOWMETER AM0 Series COMPACT FLOWMETER GENERAL AM0 series are most well accepted metal tube flowmeters which have been developed based on the long time experience of TOKYO KEISO
More informationAM-1000 Series COMPACT FLOWMETER
METAL TUBE VARIABLE AREA FLOWMETER AM0 Series COMPACT FLOWMETER GENERAL AM0 series are most well accepted metal tube flowmeters which have been developed based on the long time experience of TOKYO KEISO
More informationApplicable Fluid. Accuracy. Flow Rate Range. Fluid Temperature. Fluid Viscosity. Connection Size. Flange Rating. Housing. Material. Blade.
TOKICO TURINE METER GS-F211E- Overview Turbine meter has an excellent performance with its distinctive structure. Comparing with the flow meter using other method, it has compact and lighter design and
More informationVORTEX FLOWMETER (DELTA FLOWPET)
VORTEX FOWMETER (DETA FOWPET) DATA SHEET FMR, M This instrument is a Karman vortex flowmeter capable of measuring the flow rate of liquid, gas, and vapor. The heavyduty detecting section made of stainless
More informationCoriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM
MAXIFO TM Features MaxiFlo Coriolis Mass Flowmeter series MCM is a mass flow meter that measures mass flow, density and temperature of liquids, slurries and gases. And it even measures oil content in water.
More informationDELTA FLOWMETER FOR GAS SERVICE (INSERTION TYPE) MODEL VF SERIES
DETA FOWMETER FOR GAS SERVICE (INSERTION TYPE) MODE VF SERIES GENERA SPECIFICATION GS. No. GBD0-0-E GENERA In the thermistor type Delta meter, a probe inserted in the pipeline detects the representative
More informationED 701 General Industry Pressure Transmitter
ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationAM7000 Series GENERAL FEATURES METAL TUBE VARIABLE AREA FLOWMETER
MET TUBE VRIBE RE FOWMETER M000 Series GENER The metal tube variable area flowmeter M000 Series has been developed from M-0 Series which were based on the long time experience of TOKYO KEISO in the field
More informationPressure transmitters for industrial applications MBS 32 and MBS 33
Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer
More informationElectromagnetic Flowmeter
Overview Flokal B.V. smart electromagnetic flow meter is hallmarked by its high performance and reliability that are based on successful, field-proven technology. It s being widely used in industries such
More informationCOMPACT FLOWMETER TO COVER ALL POSSIBLE APPLICATIONS. METAL TUBE AM-1000 Series GENERAL FEATURES TG-F962-0E APR.,2000 AM-1000 COMPACT FLOWMETER
AM0 TO COVER ALL POSSIBLE APPLICATIONS METAL TUBE AM0 Series GENERAL AM0 series are most well accepted metal tube flowmeters which have been developed based on the long time experience of TOKYO KEISO in
More informationMass Flow Meter and Controller
ass Flow eter and Controller for Gases measuring monitoring analysing asuring range: 0-10 m N /min...0-500 N /min ccuracy: ±1.5% f.s. pmax 35 bar; tmax 50 C nalogue output: 0-5 V or 4-20 m Digital display
More informationE8EB-N0C2B E8EB-N0B2B
Slim Sensor CSM DS_E 1 Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree
More informationSECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:
SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine
More informationTHM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist
THM80X Series Feature Application IP67 protection degree, rugged aluminum case, fit in variety harsh environment Capable of temperature compensation Linear adjustment temperature & humidity by computer,
More informationProximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C
ASH & ALAIN INDIA PVT LTD S-00, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-000(India) Tel : 0-797575 Fax : 0-79757 E-mail : sales@ashalain.com Proximity Ideal for High Temperatures and Cleaning
More informationDMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm
DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up
More informationDigital display Pressure range ON/OFF output Linear output Model No Positive pressure 0 to 98 kpa (0 to 1 kgf/cm 2 ) NPN open collector o 1 to o5
Pressure Sensor E8CC with Built-in Microcomputer and Digital Display and New E8CB General-purpose Model Withstands a of 490 kpa (5 kgf/cm 2 ) and highly reliable. Incorporates a two-turn adjuster ensuring
More informationDMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output
More informationD5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder
with incremental encoder Draw wire encoder A40 Traverse speed max. 0.8 m/s The draw wire system A40 with incremental encoder excels with its compact construction. RoHS Compact and simple Measuring length
More informationDirect-operated 2/2-way compact solenoid valves Type EV210A
Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationImformation of C091D series
Imformation of C09D series The QTY of contacts is -pin to -pin, the connection method for the thread type, pinhole connections for welding type, press-fit and PCB type. This series of connectors to prevent
More informationDS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm
Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar
More informationSingle cam type. Double cam type. Grip force N. Type Model/size Stroke Screw type straight style. Screw type tee style
Type Model/size Stroke -SS-0-N. -SS-0-N. Single cam type -SS- 7. -SS-. -SS-4. -SD-0 Double cam type -SD- -SD-4. Screw type straight style Screw type tee style -FS- -FT- -FS- -FT- 0.9 1. 1.. 1. 4 Grip forcen
More informationTarget Insertion Flowmeter
Principle of Operation Flow is measured in terms of dynamic force acting on a target (solid disk) in the flow stream. Hermetically sealed, bonded strain gages in a bridge circuit configuration mounted
More informationDisplay counter electromechanical
Micro Display counter K 04... K 07, shock resistant 4-, 5-, 6- and 7 digit Micro adding counter High shock resistance Low power consumption; suitable for battery consumption small dimensions Large optical
More informationPilot operated 2 port solenoid valve (general purpose valve) Standard specifications NC (normally closed) type C C. 2 /s) Starting
21/22 Series (general purpose valve) 21/22 Series NC (normally closed) type, NO (normally open) type Port size: Rc1 1/4 to Rc2, 32 to 50 flange iaphragm structure JIS symbol 21: Common specifications Item
More informationCDS. high density spring connection
CDS high density spring connection DENSTY STANDARD 1A CDS DENSTY A A spring connection CDS Series The originality of multipole connectors represents one of the core values of LE, a leading company in this
More informationE6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders
Multi-turn High-precision Encoder Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders Reset function for easy origin alignment when built-into equipment. Multi-turn
More informationFeatures of Uni-Thermo
Pelti ier Device in the 21st Uni-Thermo Century Hi eliability NTENTS Comparison with a Conventional Peltier Device. The Result of Operating Reliability Test Peltier Device Uni-Thermo Quality Chart Peltier
More informationLinear measuring technology
Their extremely robust construction, their high IP69k protection level and their wide temperature range make these new draw wire encoders particularly reliable and durable. Their flexibility and adaptability
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationPro-V Multivariable Flowmeter Model M22 In-line Vortex
Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,
More informationFitting PS P - B - R2
INTERNAL STRUCTURE PS86 (G 3/8) 2 3 FEATURES Solidstate pressure switch with no mechanical moving parts Isolated output via a photo-coupler Switching pressure adjustable and hysteresis band adjustable
More information( Single Case Construction )
OVL FLOWMETER Meter Size:,,,, ( Single ase onstruction ) Pocketless Design GENERL SPEIFITION GS.No.GBB--E GENERL The OVL flowmeter is a positive displacement type flowmeter comprising a pair of oval gear
More informationPro-V Multivariable Flowmeter Model M23 Insertion Vortex
Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,
More informationVortex Flow Meters. RVL Series Vortex Flow Meter
TM Vortex Meters RVL Series Vortex Meter pplications: Water/Wastewater I Water: Semiconductor, Institutional I Water Skids Semiconductor Equipment Slurry hemical Processing RINE FEERTE IN. ISO 900 : 000
More informationPTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30
eries Features Best pressure transmission solution for small and middle sized project such as indoor heating and air conditioning, water and sewer, or incinerator, etc. Improves noise resistance and minimize
More informationCONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS CADB/T-N Series
FILTERS F7 Compact heat recovery unit with cross-flow heat exchanger in 9 sizes from 500 m 3 /h to 8.350 m 3 /h. The casing is made from aluminium profile frame with double skinned 25 mm steel panels with
More informationULTRA OVAL Meter Sizes:39, 41, 45, 50, 52, 53 w/unfactored Pulse Generator (NPG60A)
ULTRA OVAL Meter Sizes:9, 4, 45, 50, 5, 5 w/unfactored Pulse Generator (NPG60A) GENERAL SPECIFICATION GS.No.GBU0--E GENERAL ULTRA OVAL MODEL 9, 4, and45 provides extensive capability as a highly dependable
More informationISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER
ISOCON-6 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting
More informationPressure Transmitter ED 701
Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation
More informationCALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05
Modulating digital controller for heating and cooling series REGI ERED SI EN ISO 00:000 Cert. n FM UNI EN ISO 00:000 Cert. n 000 0/0 G replaces dp 0/0 Function The controller can be used with three-point
More informationDOG-1/-3. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air : 120 C. p max. : PN 40; t max
Oscillation Flowmeter for gases measuring monitoring analysing DOG1/3 Measuring ranges: 0.2 20... 200 20000 m 3 /h air p max : PN 40; t max : 120 C Connection: flange DN 25... DN 400 Material: cast iron,
More informationDM70 Hand-Held Dewpoint Meter for Spot-Checking Applications
DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed
More informationPressure. 1 Fitting PA R - N R2
INTERNAL STRUCTURE (R 1/4) 4 1 2 3 FEATURES High corrosion resistance and drip-proof construction port attachment made of Proven IP-65 grade gauge body (IP-65 in accordance with IEC) Standard product provides
More informationDifferential Pressure Switch
Features Using piezoresistive pressure sensor, which is compensated and aged well; high accuracy, quick response; Amplifier circuit driving switch relay; relay value could be set freely between zero and
More information473-SHX Dew Point Mirror
Humidity and Temperature Reference Hygrometer For Temperature up to 125 C Precise and stable chilled mirror dew point mirror technology High temperature optical components High temperature sample fan Cable
More informationSolenoid valves 2/2-way direct-operated type EV210A
MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valves 2/2-way direct-operated type EV210A EV210A covers a wide range of small, direct-operated 2/2-way solenoid valves for use in industrial machinery.
More informationOPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000
3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER Model : TM-2000 Your purchase of this THERMOMETER marks a step forward for you into the field of precision measurement. Although this THERMOMETER is a
More informationCALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%
ATEX documenting multifunction calibrator with high accuracy 0.006% is the top instrument of our range of ATEX documenting multifunction calibrators. Description is the top instrument of our range of ATEX
More informationø6, ø10, ø15, ø20, ø25, ø32, ø40, ø50, ø63 How to Order Switch rail Nil Standard stroke Refer to page 12 for standard stroke.
Magnetically Coupled Rodless Cylinder: Direct Mount ype Series ø, ø, ø, ø, ø, ø, ø, ø0, ø Direct mount type mm mm mm mm mm mm mm 0 0 mm mm 00 MB Piping type Both sides piping type Centralized piping type
More informationEC 60 TM 200W 48V. with brushless drive. brushless small & compact maintenance-free Protection IP65. Ordering Data
EC-Servo motors with brushless drive EC 0 TM 200W 48V brushless small & compact maintenance-free Protection IP Ordering Data characteristics permanently energized -phase synchronous motor incremental position
More informationFeatures of Uni-Thermo
Long-life. High reliability Uni-Thermo Peltier Device in the 1st Century CONTENTS Comparison with a Conventional Peltier Device. The Result of Operating Reliability Test Peltier Device Uni-Thermo Quality
More informationCompact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm.
Flow sensors www.ifm.com/mid Compact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm. For industrial applications Volumetric flow sensor efector mid. High-precision
More informationMODEL: R7K4FML3. Remote I/O R7K4F Series. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.)
Remote I/O R7KF Series I/O MODULE (-III) POWER INPUT DC power R: V DC (Operational voltage range: ±0 %; ripple 0 %p-p max.) 0 (8.7). (.) 7(.8) mm (inch) [] OPTIONS (multiple selections) Output data read
More informationDM70 Hand-Held Dewpoint Meter for Spot-Checking Applications
DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed
More informationSafety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.
Safety Precautions Observe the following notices to ensure personal safety or to prevent accidents. To ensure that you use this product correctly, read this User s Manual thoroughly before use. Make sure
More informationAbsolute encoders multiturn
elektronischer electronic multiturn, Multiturn, magnetic magnetisch Sendix M66 / M68 (shaft / hollow shaft) The Sendix M6 with Energy Harvesting Technology is an electronic multiturn encoder in miniature
More informationMetso Concentration Measurement 3300
Metso Concentration Measurement 3300 Metso Concentration 3300 Accurate direct in-line measurement The Concentration Measurement is provided with intelligent technology calculating the concentration of
More informationBody (Black) O-ring Stud. Effective when piping in a confined space. The body and the threaded portion can rotate (For positioning to some extent).
Antistatic One-touch Fittings Tubing: Metric Size/Connection Thread: M, Rc, G, NPT, NPTF Series KA RoS One-touch fitting with antistatic prevention. One-touch IN/OUT connection. Possible to use from vacuum
More informationCALYS 80P. Field pressure calibrator with high accuracy 0.01%
Field pressure calibrator with high accuracy 0.01% CALYS 80P is a field pressure calibrator within CALYS range with high accuracy of 0.01%. Description CALYS 80P is a field pressure calibrator within CALYS
More informationDifferential indicators
Differential indicators 5-07-006 7:8 Pagina 5 (,) Differential indicators A guarantee of maintenance to the correct ISO 06 contamination class achieved through the use of the filters can be provided exclusively
More informationCooling Water Flow Regulator
Temperature controlled, indirectly and directly actuated diaphragm valves / seat valves Port size G 3/8 to G DN 0 to DN 0 ontinuous regulation High accuracy No auxiliary energy required Technical data
More informationMODEL: CR002, CR003, CR004. ADC12 Display shield. Liquid (Density range: 0.3 to 2.0g/mL) Operating temperature range
Liquid Inexpensive Microflow Coriolis Flowmeter CoriMate Ⅱ MODEL: CR002, CR003, CR004 GENERAL Based on the knowledge and experience on Coriolis technologies OVAL has gained over many years, the Corimate
More informationDS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.
DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link
More informationv = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes
Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes Examples of Application Flow measurements also in hazardous locations X zone 0 or zone 1 in clean rooms in air
More informationVaisala DRYCAP Hand-Held Dewpoint Meter DM70. Fast Response - Low Maintenance
Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 Fast Response - Low Maintenance DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand- Held Dewpoint Meter DM70 offers accurate
More informationPro-V Multivariable Flowmeter Model M23 Insertion Vortex
Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,
More information473 Dew Point Hygrometer
gh Performance Chilled Hygrometer With Cable Mounted Measuring Heads ghly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct insertion
More informationMODEL : TX Series (Nom. sizes 15mm to 400mm)
iquid High performance and wide viscosity range EX TURBINE MODE : TX Series (Nom. sizes 15mm to 4mm) GENERA EX TURBINE is an industrial turbine meter for consistent and accurate liquid flow measurement.
More informationGRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps
GRUNDFOS DATA BOOKLET MAGNA, UPE Series circulator pumps Contents Product data MAGNA/UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids 3 Type key Performance
More informationDirect Operated Type Solenoid Operated Proportional Directional Control Valve
Direct Operated Type Solenoid Operated Proportional Directional Control Valve Features These four-way proportional directional control valves enable control of the forward and reverse motion of an actuator.
More informationAmphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH
Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH General information These connectors are designed and produced in conformity with the low-voltage directive (/3/EWG) respectively
More informationEX-EMERGENCY LIGHT FITTINGS
EX-EMERGENCY LIGHT FITTINGS nllk 0...N 1-36 W Plastic version for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 N are conform to the requirements of the ATEX-Directive
More informationw w w. i n t e l l i g e n t a c t u a t o r. d e
GB SCARA ROBOT w w w. i n t e l l i g e n t a c t u a t o r. d e 0.2 400 IX-NNW70(7040) 0.2 400 IX-NNW80(8040) (inverse) T(U)NN TNN UNN IX-T(U)NN301 IX-T(U)NN31 IX-H(I)NN0 (inverse) HNN IX-H(I)NN60 H(I)NN
More informationv = 00,20 m/s Thermal Flow Sensors TA with thin-film sensor element Probes Probe guides Measuring tubes
with thin-film sensor element Probes Probe guides Measuring tubes Examples of Application Flow measurements also in hazardous locations Ex zone 0 or zone 1 in clean rooms in air conditioning and ventilating
More informationOPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820
Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820 Your purchase of this PEN VIBRATION METER marks a step forward for you into the field of precision measurement.
More informationTF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.
TF / TF -Ex Field mounted temperature transmitters, PROFIBUS PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN P R O F I PROCESS FIELD BUS B U S Input Resistance thermometer (,, -wire
More informationBEFORE USE... POINTS OF CAUTION COMPONENT IDENTIFICATION INSTRUCTION MANUAL MODEL R7K4DH-1-DAC32D R7K4DH-1-DAC32D
INSTRUCTION MANUAL PNP DISCRETE INPUT & PNP TRANSISTOR OUTPUT MODULE, 6 points each (High-speed Link System, e-con connector) R7KDH--DACD MODEL R7KDH--DACD BEFORE USE... Thank you for choosing M-System.
More informationDirect-operated 2/2-way solenoid valves Type EV210B
Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance
More informationOperating Instructions for Digital Manometer. Model: MAN-SD
Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5
More informationThe Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:
The basic PC software is supplied free with the recorder. There is an additional charge for the extensive Data Acquisition Software supplied with communication of RS-232/422/485 or Ethernet. The Ordering
More informationTF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels
TF 0 / TF 0-Ex Field mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.69 EN USA Input Resistance thermometer (,, wire circuit) Thermocouples
More informationLEVEL CONTROLS. Selection Guide. Capacitance Calculations and Data For Selecting Robertshaw Level Control Instruments and Sensing Probes
LEVEL CONTROLS Selection Guide Capacitance Calculations and Data For Selecting Robertshaw Level Control Instruments and Sensing Probes Capacitance Probe Calculations The following data is compiled to assist
More informationFKC... 5 DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER FEATURES SPECIFICATIONS. Functional specifications
FKC... 5 DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER The FCX AIII differential pressure (flow) transmitter accurately measures differential pressure, liquid level, gauge pressure or flow rate and transmits
More informationFlow Meter FVone-NP-CA. FVone-NP-CA 11 (Plug-in type) (Screw-in type) Recommended for: DN 20 DN 80 Required accessory: Cable type 31.
FVone-NP- 00/ (Push-in type) Recommended for: DN and bigger Required accessory: Threaded installation bush able type Optional accessory: PTFE sealing ring Locking set FVone-NP- 0/0 (Screw-in type) Recommended
More informationOPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820
Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820 Your purchase of this PEN VIBRATION METER marks a step forward for you into the field of precision measurement.
More informationPG-200/PG-208 PRESSURE GAUGES P G G P P
Digital 3 1/2 digits monitor Set button for switch output HI or LO (PG-200) (PG-208) Digital 3 1/2 digits Power switch LO setting VR for switch output LO HI setting VR for switch output HI SPAN adjustment
More informationAcceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202
Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202 Your purchase of this VIBRATION METER marks a step forward for you into the field of precision measurement. Although this METER is
More informationAUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08
AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08 Introduction The HAH1BVW family is for the electronic measurement of DC, AC or pulsed currents in high power and low voltage automotive applications
More informationSERIES FMP. Working pressure. 280 bar. Style D Style V Style Z. Style T. Style B. Style S B B D.I. D.I. D.I. D.I. D.I. D.I.
6 FMP SERIES FMP Working pressure 80 bar Style S Style Style T Style D Style V Style Z 7 Technical data Filter body (Materials) ead: Cast iron (chemical heat treatment) ousing: Cast iron (chemical heat
More information473 Dew Point Hygrometer
High Performance Chilled Mirror Hygrometer With Cable Mounted Measuring Heads Highly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct
More informationConnector~Tech Providing Harsh Environment Connector
Connector~Tech www.connectortech.com.au Providing Harsh Environment Connector SOLUTIONS Tajimi TC18 series connectors are water-pro up to 30 meters in depth. Economical and highly reliable construction