1 Oscillation Flow Meter for Gases measuring monitoring analysing Measuring ranges: 0.2 to 000 m 3 /h air pmax: PN 0, tmax: 0 C Connection: flange DN 25 DN 00 : Cast Iron, steel or stainless steel Accuracy: ±1.5% of measured value No moving parts Longterm stability KOBOLD companies worldwide: ARGENTINA, AUSTRIA, BELGIUM, CANADA, CHILE, CHINA, CZECHIA, FRANCE, GERMANY, GREAT BRITAIN, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, POLAND, SINGAPORE, SLOVAKIA, SPAIN, SWITZERLAND, THAILAND, USA, VENEZUELA, VIETNAM KOBOLD Messring GmbH Nordring 222 D719 Hofheim/Ts. +9(0) Fax +9(0) info.de@kobold.com Internet: Model: DOG1 DOG3 3

2 Oscillation Flow Meter for Gases Model: DOG1 and DOG3 Description The KOBOLD flow meter DOG1 and DOG3 are used for noncontact flow measurement of gases. The medium flows through an orifice in a tube. Bypass bores are located at the sides. The dynamic pressure at the orifice causes part of the gas volumetric flow to flow into the bypass. The division ratio remains constant over the whole measuring range. FluidistorOscillator The bypass channel contains the Fluidistor Oscillator the measuring cell itself. When the gas flows through the measuring cell, a gas column oscillates in a ushaped channel mounted to the left and right. This oscillation frequency is proportional to the flow velocity and thus to the total volume flow. The oscillation frequency is sensed with a hot wire sensor. An electrical alternating signal is generated that is displayed in the seriesconnected electronics. Application The inner, connected flow channels are generously dimensioned. The constant changes of direction of the flow in the channels have a selfcleaning effect. The devices are therefore extremely dirt resistant and have no consumables. The mounting position can be chosen at will. When condensate forms in the gas, the horizontal mounting position with the sensing element pointing upwards is recommended. The gas flow velocity anywhere in the pipework upstream of the flow meter should not exceed the sound velocity. Pressure drops above critical and pulsating streams must be avoided. The recommended inlet pipe section is 10xDN and the outlet pipe section 5xDN. Areas of application Compressed air Natural gas, biogas, fermentation gas Propane Hydrogen gas Nitrogen Argon Technical details Measuring accuracy: ±1.5% of meas. value (at Q t 100%*) ±5% of measured value (at 1% Q t *) *The lower limit Q t depends on the density Q t = % at density 1 kg/m 3 Q t = % at density 2 kg/m 3 Q t = 2% at density kg/m 3 Q t = 1% at density kg/m 3 Repeatability: 0.1% of measured value Max. temperature:...+0 C C (ExVersion) Ambient temperature: max. 0 C C (ExVersion) Operating pressure: DOG11/.., DOG31/32..: PN 16 DOG/13.., DOG32/33..: PN 0 Span: DOG1..: 1: 100 DOG3..: 1: 50 Sensor: hotwire, RDC Pulses: max. Hz Protection: IP s Case DOG11..: cast Iron GG25 DOG13..: Steel St. 35. DOG33..: Steel St. 523N DOG/32..: St. steel Orifice: stainless steel 1.36 Sensing element: polyphenylene sulfide (PPS) Sensor: Platinum Gaskets: silicone, nitrile or FPM Electronics Electrical connection: Cable with PGthread Display: digit LCD display, counter Power supply: 230 V AC 10%, +%/62 Hz Input: hot wire sensor Pulse 1: V DC, max.100 ma, Open Collector Pulse 2: floating contact decadic 250 V AC, max. 3 A Analogue : 0 ma or ma max. 500 Ω Ambient temperature: 0 to +50 C Permissible distance: max. 50 m to DOG1...DOG3 Connection cable: minimum 0.5 mm 2, screening recommended ExVersion: II 1G EEx ia IIC T

3 Oscillation Flow Meter for Gases Model: DOG1 and DOG3 Order details for DOG1 with flange (example: DOG1101L F25N S ER00) Meas. range m 3 /h air cast Iron Model Connection flange Gasket Evaluat. electronics steel stainless steel Standard PN 16 only GG, VA Special PN 0 only St., VA DOG1101L.. DOG1102L.. DOG1103L.. DOG01L.. DOG02L.. DOG03L.. F25N=DN25 F25S=DN DOG130L.. DOG1305L.. DOG1306L.. F32N=DN32 F32S=DN DOG1107L.. DOG110L.. DOG1109L.. DOG07L.. DOG0L.. DOG09L.. F0N=DN0 F0S=DN DOG1110L.. DOG1111L.. DOG11L.. DOG10L.. DOG11L.. DOGL.. F50N=DN50 F50S=DN50 with external electronics DOG1116L.. DOG1117L.. DOG11L.. DOG1119L.. DOG10L.. DOG11L.. DOG1313L.. DOG131L.. DOG1315L.. DOG1322L.. DOG1323L.. DOG132L.. DOG1325L.. DOG1326L.. DOG1327L.. DOG13L.. DOG1L.. DOG15L.. DOG16L.. DOG17L.. DOGL.. DOG19L.. DOGL.. DOG21L.. DOG22L.. DOG23L.. DOG2L.. DOG25L.. DOG26L.. DOG27L.. FN=DN F0N=DN0 F1HN=DN100 F1ZN=DN5 F1FN=DN150 FS=DN F0S=DN0 F1HS=DN100 F1ZS=DN5 F1FS=DN150 S=Silicone N=Nitrile V=FPM...A display, no EX protection,...d and total, no EX protection,...e display, with EX protection, DOG132L.. DOG1329L.. DOG1330L.. DOG1331L.. DOG1332L.. DOG1333L.. DOG2L.. DOG29L.. DOG30L.. DOG31L.. DOG32L.. DOG33L.. F2HN=DN F2FN=DN250 F2HS=DN* F2FS=DN250*...X and total, with EX protection, with analogue and pulse DOG133L.. DOG1335L.. DOG1336L.. F3HN=DN F3HS=DN DOG1337L.. DOG133L.. DOG1339L.. F3FN=DN DOG130L.. DOG131L.. DOG132L.. FHN=DN00 *not for DOG (stainless steel) Please state the exact operating conditions (gas types, flow volume, pressure, temperature, installation position etc.) when ordering. 5

4 Oscillation Flow Meter for Gases Model: DOG1 and DOG3 Order details for DOG3 with Wafer design (example: DOG3301L F25N S A) Meas. range m 3 /h air steel Model stainless steel Connection Wafer design Standard PN 16 Special PN 0 Gasket Evaluat. electronics DOG3301L.. DOG3302L.. DOG3303L.. DOG31L.. DOG32L.. DOG33L.. F25N=DN25 F25S=DN DOG3307L.. DOG330L.. DOG3309L.. DOG37L.. DOG3L.. DOG39L.. F0N=DN0 F0S=DN DOG3310L.. DOG3311L.. DOG33L.. DOG3313L.. DOG331L.. DOG3315L.. DOG3316L.. DOG3317L.. DOG33L.. DOG3210L.. DOG3211L.. DOG32L.. DOG3213L.. DOG321L.. DOG3215L.. DOG3216L.. DOG3217L.. DOG32L.. F50N=DN50 FN=DN F0N=DN0 F50S=DN50 FS=DN F0S=DN0 with external electronics...a display, no EX protection, DOG3319L.. DOG33L.. DOG3321L.. DOG3322L.. DOG3323L.. DOG332L.. DOG3325L.. DOG3326L.. DOG3327L.. DOG332L.. DOG3329L.. DOG3330L.. DOG3331L.. DOG3332L.. DOG3333L.. DOG333L.. DOG3335L.. DOG3336L.. DOG3219L.. DOG32L.. DOG3221L.. DOG3222L.. DOG3223L.. DOG322L.. DOG3225L.. DOG3226L.. DOG3227L.. DOG322L.. DOG3229L.. DOG3230L.. DOG3231L.. DOG3232L.. DOG3233L.. DOG323L.. DOG3235L.. DOG3236L.. F1HN=DN100 F1ZN=DN5 F1FN=DN150 F2HN=DN F2FN=DN250 F3HN=DN F1HS=DN100 F1ZS=DN5 F1FS=DN150 F2HS=DN F2FS=DN250 F3HS=DN S = Silicone N = Nitrile V =FPM...D and total, no EX protection,...e display, with EX protection,...x and total, with EX protection, with analogue and pulse DOG3337L.. DOG333L.. DOG3339L.. DOG3237L.. DOG323L.. DOG3239L.. F3FN=DN350 F3FS=DN DOG330L.. DOG331L.. DOG332L.. DOG3L.. DOG321L.. DOG322L.. FHN=DN00 FHS=DN00 Please state the exact operating conditions (gas types, flow volume, pressure, temperature, installation position etc.) when ordering. 6

5 Oscillation Flow Meter for Gases Model: DOG1 and DOG3 Pressure loss/ flow The diagram applies for gases with a density of air at NPT (0 C and 1000 mbar). The pressure loss is always proportional to the density of the gas. For example, the pressure loss doubles at 100% higher operating pressure. Calculating the actual density The actual density can be calculated with the following formula: D= D 0 i P i T 0 T D 0 = density at 1 bar abs. and 0 C (= 273 K) T = temperature in K (= C for example C = = 293 K T 0 =273 K P = operating pressure in bar (absolute pressure) Dimensions and weight DOG1 L H Calculating the norm flow Q N = Q P 273 1,013 T Q N = norm flow at bar abs. and 0 C Q = operating flow P = operating pressure in bar (absolute pressure) T = operating temperature in K D Dh Ds DN L D Dh Ds Number of holes H H with AVF Weight [kg] or ,

6 Oscillation Flow Meter for Gases Model: DOG1 and DOG3 Dimensions and weight DOG3 Dimensions of electronics DN 50 DN mm D mm Weight kg Accessory Valve in the bypass (between measuring tube and measuring cell) for easy sensor changing and for protection of the sensor when starting the installation.

DOG-1/-3. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air : 120 C. p max. : PN 40; t max

DOG-1/-3. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air : 120 C. p max. : PN 40; t max Oscillation Flowmeter for gases measuring monitoring analysing DOG1/3 Measuring ranges: 0.2 20... 200 20000 m 3 /h air p max : PN 40; t max : 120 C Connection: flange DN 25... DN 400 Material: cast iron,

More information

Thermal Mass Flow Meter for Gases

Thermal Mass Flow Meter for Gases Thermal Mass Flow Meter for Gases measuring monitoring analysing Direct mass flow rate measurement of gases Measuring accuracy: ±1.0% f.s. +0.5% m.v. pmax PN 16, tmax 175 C Fast response time No moving

More information

DVZ. Vortex Flowmeter Compact. for low viscosity liquids. Range: l/min. Accuracy: ±2.5% of full scale. p max : 20 bar; t max : 80 C

DVZ. Vortex Flowmeter Compact. for low viscosity liquids. Range: l/min. Accuracy: ±2.5% of full scale. p max : 20 bar; t max : 80 C Vortex Flowmeter Compact for low viscosity liquids measuring monitoring analysing DVZ Range: 0.4. 000 l/min Accuracy: ±.% of full scale p max : 0 bar; t max : 80 C Connections: G ¼... G, ¼" NPT..." NPT

More information

Infrared Hand-Held Thermometers

Infrared Hand-Held Thermometers Infrared Hand-Held Thermometers measuring monitoring analysing Model: TIR-H... Measuring range from -2... 5 C to -32... 9 C Measuring accuracy: ±1% to ± 2% of measured value Option: analogue output, RS

More information

Full Metal Variable Area Flow Meter and Counter

Full Metal Variable Area Flow Meter and Counter Full Metal Variable rea Flow Meter and Counter for horizontal and vertical mounting measuring monitoring analysing Special versions up to 600 bar Measuring range: 10-100...00-000 L/h water 0.3-3.0...-0

More information

MIK. Electromagnetic Flowmeter Compact. for conductivity liquids. Range from liquids, acids and caustic solutions:

MIK. Electromagnetic Flowmeter Compact. for conductivity liquids. Range from liquids, acids and caustic solutions: Electromagnetic Flowmeter Compact for conductivity liquids measuring monitoring analysing MIK Range from liquids, acids and caustic solutions: 0.0-0. 3-700 l/min frequency-, switching-, analogue output

More information

Mass Flow Meter and Controller

Mass Flow Meter and Controller ass Flow eter and Controller for Gases measuring monitoring analysing asuring range: 0-10 m N /min...0-500 N /min ccuracy: ±1.5% f.s. pmax 35 bar; tmax 50 C nalogue output: 0-5 V or 4-20 m Digital display

More information

MIK. Electromagnetic Flowmeter Compact. for conductivity liquids

MIK. Electromagnetic Flowmeter Compact. for conductivity liquids Electromagnetic Flowmeter Compact for conductivity liquids measuring monitoring analysing MIK MIK with frequency-, switching-, analogue output MIKwith digital plug on display Range from liquids, acids

More information

Industrial Resistance Thermometers according to DIN Model MWD

Industrial Resistance Thermometers according to DIN Model MWD Industrial Resistance Thermometers according to DIN measuring monitoring analysing MWD OMeasuring O range: -98... +600 ºC O O Pt00 sensor: class A, class B, class /3, class /0, or O O Output: resistance

More information

TSK. Flap-Type Flowmeter. Range: to GPM Accuracy: ± 2.5% of Full Scale P max. : 580 PSI T max

TSK. Flap-Type Flowmeter. Range: to GPM Accuracy: ± 2.5% of Full Scale P max. : 580 PSI T max Flap-Type Flowmeter measuring monitoring analyzing TSK Range: 6.6...26.4 to 880...6600 GPM Accuracy: ± 2.5% of Full Scale P max : 580 PSI T max : -40 572 F Connection: Wafer Flange 1.5" 20" ASME Material:,

More information

Infrared Hand-Held Thermometers

Infrared Hand-Held Thermometers Infrared Hand-Held Thermometers measuring monitoring analysing Model: TIR-H... Measuring range from -2 to 5 C to -32 to 9 C Measuring accuracy: ±1% to ± 2% of measured value Option: analogue output, RS

More information

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement

More information

Operating Instructions for Digital Manometer. Model: MAN-SD

Operating Instructions for Digital Manometer. Model: MAN-SD Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5

More information

Ultrasonic Gas Flow Meter

Ultrasonic Gas Flow Meter P r o d u c t i n f o r m at i o n FLOWSIC600 Ultrasonic Gas Flow Meter For custody transfer and process applications Analyzers and Process Instrumentation FLOWSIC600 For Custody Transfer and Process Applications

More information

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27 Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for

More information

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes Examples of Application Flow measurements also in hazardous locations X zone 0 or zone 1 in clean rooms in air

More information

close to performances of the turbine gas meters designed for custody transfer measurements.

close to performances of the turbine gas meters designed for custody transfer measurements. QUANTOMETER DESIGN AND FUNCTION CPT Quantometers have been designed in order to provide our customers with reliable and inexpensive measuring instruments for secondary flow measurements. Our great experience

More information

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,

More information

Facts and figures MULTILIFT SELECT 15

Facts and figures MULTILIFT SELECT 15 Facts and figures MULTILIFT SELECT 15 www.arburg.com MULTILIFT SELECT 15 Technical data min. 180 Stroke Z-axis Stroke X-axis Clamping face fixed mould platen 220 E A D K Stroke Y axis 195 B 2) C 157 P

More information

v = 00,20 m/s Thermal Flow Sensors TA with thin-film sensor element Probes Probe guides Measuring tubes

v = 00,20 m/s Thermal Flow Sensors TA with thin-film sensor element Probes Probe guides Measuring tubes with thin-film sensor element Probes Probe guides Measuring tubes Examples of Application Flow measurements also in hazardous locations Ex zone 0 or zone 1 in clean rooms in air conditioning and ventilating

More information

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181 Siemens AG 09 SITRANS F flowmeters System information Overview Siemens offers two types of ultrasonic flowmeters, in-line flowmeters and clamp-on flowmeters. This offers the end user the maximum flexibility

More information

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up

More information

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level

More information

Direct-operated 2/2-way compact solenoid valves Type EV210A

Direct-operated 2/2-way compact solenoid valves Type EV210A Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together

More information

Direct-operated 2/2-way solenoid valves Type EV210B

Direct-operated 2/2-way solenoid valves Type EV210B Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance

More information

Gear Wheel Flowmeter for viscous liquids Model DZR. (option 3):

Gear Wheel Flowmeter for viscous liquids Model DZR. (option 3): Gear Wheel Flowmeter for viscous liquids measuring monitoring analysing DZR easuring range:. -... 3-7 l/min Accuracy: ±.3... ±1% of reading p max : bar t max : 1 C Orocess O connection: G ⅛, G ⅜, G ½,

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 07 Overview Function SITRANS LH00 Transmitter for hydrostatic level U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/

More information

Volumetric Flow Measurement

Volumetric Flow Measurement Volumetric Flow Measurement TVF Series Vortex Flow Meter Xi an Tosilon Automation Co., Ltd No.299, Daqing Rd, Lianhu District, Xi'an Shaanxi, China Tel: +86-29-8823 8550 info@tosilon.com; www.tosilon.com

More information

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,

More information

Solenoid valves 2/2-way direct-operated type EV210A

Solenoid valves 2/2-way direct-operated type EV210A MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valves 2/2-way direct-operated type EV210A EV210A covers a wide range of small, direct-operated 2/2-way solenoid valves for use in industrial machinery.

More information

Solenoid valves Type EVR 2 g 40 NC/ NO New EVR 6 with Steel cover design

Solenoid valves Type EVR 2 g 40 NC/ NO New EVR 6 with Steel cover design MAKING MODERN LIVING POSSIBLE Technical brochure Solenoid valves EVR 2 g 40 NC/ NO New with Steel cover design EVR is a direct or servo operated solenoid valve for liquid, suction, and hot gas lines with

More information

Compact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm.

Compact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm. Flow sensors www.ifm.com/mid Compact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm. For industrial applications Volumetric flow sensor efector mid. High-precision

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

HiPace 1200, with TC 1200, DN 200 CF-F

HiPace 1200, with TC 1200, DN 200 CF-F HiPace 1200, with TC 1200, DN 200 CF-F HiPace 1200, with TC 1200, DN 200 CF-F Similar Image Powerful turbopump with a pumping speed of up to 1250 l/s for N 2 DN 200 CF-F flange for demanding UHV applications

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

VersaFlow Ultrasonic clamp-on Flowmeter Specifications

VersaFlow Ultrasonic clamp-on Flowmeter Specifications VersaFlow Ultrasonic clamp-on Flowmeter Specifications 34-VF-03-14 September 2009 Clamp-On Technology HONEYWELL S VersaFlow stands for continuity and long term reliability. Flow measurement can be done

More information

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

Coriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM

Coriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM MAXIFO TM Features MaxiFlo Coriolis Mass Flowmeter series MCM is a mass flow meter that measures mass flow, density and temperature of liquids, slurries and gases. And it even measures oil content in water.

More information

Electromagnetic Flowmeter

Electromagnetic Flowmeter Overview Flokal B.V. smart electromagnetic flow meter is hallmarked by its high performance and reliability that are based on successful, field-proven technology. It s being widely used in industries such

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output

More information

CALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05

CALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05 Modulating digital controller for heating and cooling series REGI ERED SI EN ISO 00:000 Cert. n FM UNI EN ISO 00:000 Cert. n 000 0/0 G replaces dp 0/0 Function The controller can be used with three-point

More information

BSH Description. 2. Features. 3. Applications. 4. Pinning information. N-channel enhancement mode field-effect transistor

BSH Description. 2. Features. 3. Applications. 4. Pinning information. N-channel enhancement mode field-effect transistor M3D88 Rev. 25 August 2 Product specification. Description in a plastic package using TrenchMOS technology. Product availability: in SOT23. 2. Features TrenchMOS technology Very fast switching Logic level

More information

MX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E

MX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E OMPT ND USER FRIENDLY MX Series Metal Tube Type Variable rea Flowmeter OUTLINE MX Series flowmeter is the metal tube type variable area flowmeter having the unified face-to-face dimension. The compact

More information

2017 Source of Foreign Income Earned By Fund

2017 Source of Foreign Income Earned By Fund 2017 Source of Foreign Income Earned By Fund Putnam Emerging Markets Equity Fund EIN: 26-2670607 FYE: 08/31/2017 Statement Pursuant to 1.853-4: The fund is hereby electing to apply code section 853 for

More information

Oscillating Flow Characteristics of a Regenerator under Low Temperature Conditions

Oscillating Flow Characteristics of a Regenerator under Low Temperature Conditions Oscillating Flow Characteristics of a generator under Low Temperature Conditions K. Yuan, L. Wang, Y.K. Hou, Y. Zhou, J.T. Liang, Y.L. Ju * Cryogenic laboratory, Technical Institute of Physics and Chemistry,

More information

ISEmax CAM40/CAS40. Technical Information

ISEmax CAM40/CAS40. Technical Information Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works

More information

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar

More information

Technical specification FLUXUS F502TE

Technical specification FLUXUS F502TE Technical specification FLUXUS F502TE Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate Precise and intelligent energy measuring

More information

Capacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z

Capacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z Technical Information TI 271F/00/en Operating Instructions 017182-1000 Capacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z Transmitters for capacitance probes Application The electronic inserts

More information

HiPace 300 with TC 110 and power supply pack OPS 100, DN 100 CF-F

HiPace 300 with TC 110 and power supply pack OPS 100, DN 100 CF-F HiPace 300 with TC 110 and power supply pack OPS 100, DN 100 CF-F HiPace 300 with TC 110 and power supply pack OPS 100, DN 100 CF-F Similar Image Rugged, powerful turbopump with a pumping speed of up to

More information

GB. Spring loaded full lift safety valve flanged, with open bonnet Series PV61-1-

GB. Spring loaded full lift safety valve flanged, with open bonnet Series PV61-1- 0 07.7 05..GB Spring loaded full lift safety valve d, with open bonnet Series PV6 -- Series PV 6 Spring loaded full lift safety valve d, with open bonnet Application The safety valve Series PV 6 is certified

More information

DS 200 DS 200 DRUCK & TEMPERATUR LEITENBERGER GMBH. Electronic Pressure Switch. Stainless Steel Sensor. Electronic Pressure Switch

DS 200 DS 200 DRUCK & TEMPERATUR LEITENBERGER GMBH. Electronic Pressure Switch. Stainless Steel Sensor. Electronic Pressure Switch DRUCK & TEMPERATUR LEITENBERGER GMBH DS 00 Electronic Pressure Switch Stainless Steel Sensor accuracy according to IEC 00: standard: 0. % FSO option: 0. % FSO Nominal pressure: from 0... 00 mbar up to

More information

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application Type 2657...59 DN 10 up to 80 mm; Plastic; 2/2 way dvantages/benefits ntegrated pilot valves, position feed-back and limit switches available Customized system solutions with Burkert valves & sensors With

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET MAGNA, UPE Series circulator pumps Contents Product data MAGNA/UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids 3 Type key Performance

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET Series circulator pumps Contents Product data MAGNA and UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids 3 Type key Performance

More information

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components: SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine

More information

Fittings and Pipe Connections

Fittings and Pipe Connections KWD Market Report Fittings and Pipe Connections Europe 2016 Situation and Trends for Heating & Plumbing Pipe Systems Contents: 1. Fittings and pipe connections Europe 2016 page 6 2. Terms and definitions

More information

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,

More information

98 Series Backpressure Regulators and Relief Valves

98 Series Backpressure Regulators and Relief Valves 9 Series Backpressure Regulators and Relief Valves Bulletin.:9 November 09 W TYPE 9H W TYPE 9LD Figure. Typical 9 Relief Valves Introduction W TYPE 9HD The 9 Series (Figure ) is used for backpressure or

More information

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8. TF / TF -Ex Field mounted temperature transmitters, PROFIBUS PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN P R O F I PROCESS FIELD BUS B U S Input Resistance thermometer (,, -wire

More information

Gear Wheel Flow Meter for Viscous Fluids

Gear Wheel Flow Meter for Viscous Fluids Gear Wheel Flow Meter for Viscous Fluis measuring monitoring analysing Measuring range:. to 5 L/min Measuring accuracy: ±.3 up to ±1% of actual flow pmax: bar tmax: C rocess connection: G 1, G 3, G 1,

More information

Applicable Fluid. Accuracy. Flow Rate Range. Fluid Temperature. Fluid Viscosity. Connection Size. Flange Rating. Housing. Material. Blade.

Applicable Fluid. Accuracy. Flow Rate Range. Fluid Temperature. Fluid Viscosity. Connection Size. Flange Rating. Housing. Material. Blade. TOKICO TURINE METER GS-F211E- Overview Turbine meter has an excellent performance with its distinctive structure. Comparing with the flow meter using other method, it has compact and lighter design and

More information

Cooling Water Flow Regulator

Cooling Water Flow Regulator Temperature controlled, indirectly and directly actuated diaphragm valves / seat valves Port size G 3/8 to G DN 0 to DN 0 ontinuous regulation High accuracy No auxiliary energy required Technical data

More information

FXP DATASHEET JUNHO 2013

FXP DATASHEET JUNHO 2013 FXP DATASHEET JUNHO 01 Data Sheet D1S0U0 Rev. 0. FXP000 (PARTI-MAG II) Electromagnetic Flowmeter Model DP1F and DPF Measurement made easy For full and partially full pipelines (free and surface pipelines)

More information

Ex floating switches and Ex immersion probes

Ex floating switches and Ex immersion probes Ex floating switches and Ex immersion probes Controlling devices with ball-operated microswitch, for signalling or regulation of liquid levels Jola Spezialschalter GmbH & Co. KG Klostergartenstr. 11 67466

More information

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO. DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link

More information

Level Sensor PanCake PR 6251 and Mounting Kit PR 6051

Level Sensor PanCake PR 6251 and Mounting Kit PR 6051 Level Sensor PanCake PR 6251 and Mounting Kit PR 6051 The space-saving solution for simple applications The sensors of the PR 6251 series have been specially designed for simple weighing of silos and horizontal

More information

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30 eries Features Best pressure transmission solution for small and middle sized project such as indoor heating and air conditioning, water and sewer, or incinerator, etc. Improves noise resistance and minimize

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET MAGNA, UPE Series circulator pumps Contents Product data MAGNA and UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids Type key

More information

Pressure transmitters for industrial applications MBS 32 and MBS 33

Pressure transmitters for industrial applications MBS 32 and MBS 33 Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer

More information

DELTA FLOWMETER FOR GAS SERVICE (INSERTION TYPE) MODEL VF SERIES

DELTA FLOWMETER FOR GAS SERVICE (INSERTION TYPE) MODEL VF SERIES DETA FOWMETER FOR GAS SERVICE (INSERTION TYPE) MODE VF SERIES GENERA SPECIFICATION GS. No. GBD0-0-E GENERA In the thermistor type Delta meter, a probe inserted in the pipeline detects the representative

More information

By-Pass. This voltage is proportional to the liquid level (threewire potentiometer circuit). The resistance reading can

By-Pass. This voltage is proportional to the liquid level (threewire potentiometer circuit). The resistance reading can " " ' " ' / The magnetic field which is in the ball or cylindrical floats actuates very small reed contacts through the wall of a guide tube and these pick up an uninterrupted measuring-circuit voltage

More information

Cyclone Click to go to the page. Cyclone

Cyclone Click to go to the page. Cyclone Cyclone.0311.2 Click to go to the page Cyclone The Cyclone (1,000-8,000 CFM) Suitable for collection of virtually any type of dust Applications: Heavy Moulding Grinding Planing Cabinet Shops Dust Transfer

More information

IN-FLOW Industrial Style Digital Mass Flow Meters and Controllers for Gases

IN-FLOW Industrial Style Digital Mass Flow Meters and Controllers for Gases IN-FLOW Industrial Style Digital Mass Flow Meters and Controllers for Gases > Introduction Bronkhorst High-Tech B.V., the European market leader in low flow thermal and Coriolis Mass Flow Meters/Controllers,

More information

FLOW SENSOR FOR LIQUID MEDIA Serie 210

FLOW SENSOR FOR LIQUID MEDIA Serie 210 FLOW SENSOR FOR LIQUID MEDIA Serie 0 Flow range 0.... 0 l/min Nominal diameters DN 6 / 8 / 0 / / 0 / Temperature measurement -0... + ÀC In comparison to the OEM flow sensor (type 00), the type 0 is available

More information

Gear Wheel Flow Meter for Viscous Fluids

Gear Wheel Flow Meter for Viscous Fluids Gear Wheel Flow Meter for Viscous Fluis measuring monitoring analysing Measuring range:. to 5 L/min Measuring accuracy: ±.3 up to ±1% of actual flow pmax: bar tmax: C rocess connection: G 1, G 3, G 1,

More information

P1.33 ECONOMICAL THERMAL MASS FLOW SENSOR BASED ON CONSTANT TEMPERATURE ANEMOMETRY

P1.33 ECONOMICAL THERMAL MASS FLOW SENSOR BASED ON CONSTANT TEMPERATURE ANEMOMETRY P1.33 ECONOMICAL THERMAL MASS FLOW SENSOR BASED ON CONSTANT TEMPERATURE ANEMOMETRY Lötters, Joost Bronkhorst High-Tech B.V Nijverheidsstraat 1a, 7261 AK Ruurlo, The Netherlands E-mail: JCLotters@Bronkhorst.com

More information

Coriolis Mass Flow Measurement System promass 60 (HART)

Coriolis Mass Flow Measurement System promass 60 (HART) Technical Information TI 029D/06/en No. 5006899 Coriolis Mass Flow Measurement System promass 60 (HART) Cost-effective mass flow measurement for liquids and gases Flexible System The system can be customised

More information

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC HYGRASGARD AFF - LC AFTF - LC sensors, calibrateable, with and active passive output Quality product for HVAC sector, accuracy % r.h. The calibrateable room humidity and temperature sensor HYGRASGARD KFF

More information

PR CYCLONE SECONDARY SHUTOFF

PR CYCLONE SECONDARY SHUTOFF EN PR CYCLONE SECONDARY SHUTOFF ORIGINAL INSTRUCTIONS CYCLONE SECONDARY SHUTOFF PR530 CYCLONE SECONDARY SHUTOFF PR330 CYCLONE SECONDARY SHUTOFF PR200-250 CYCLONE SECONDARY SHUTOFF PR150 TECHNICAL DATA

More information

P303 Pressure Regulator

P303 Pressure Regulator P0 Pressure Regulator Minimize Sudden Downstream Load Change Wide Pressure Ranges Integral Monitoring The BelGAS P0 and P0H gas pressure reducing regulators are available with a true monitor regulator,

More information

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009 VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet 34-VF-03-14 September 2009 Specification Clamp-on technology HONEYWELL S VERSAFLOW stands for continuity and long term reliability. Flow measurement

More information

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels TF 0 / TF 0-Ex Field mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.69 EN USA Input Resistance thermometer (,, wire circuit) Thermocouples

More information

HiPace 300 with TC 110, DN 100 CF-F

HiPace 300 with TC 110, DN 100 CF-F HiPace 300 with TC 110, DN 100 CF-F HiPace 300 with TC 110, DN 100 CF-F Rugged, powerful turbopump with a pumping speed of up to 260 l/s for N 2 Integrated TC 110 drive electronics Ideal for UHV applications

More information

Flow Measurement. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/22 Siemens FI

Flow Measurement. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/22 Siemens FI Function All are based on Faraday s law of induction: U M = B v d k U M = Measured voltage induced in the medium perpendicular to the magnetic field and the flow direction. The voltage is tapped at two

More information

Accumulators Virginia KMP Suction Line Accumulators

Accumulators Virginia KMP Suction Line Accumulators Accumulators Virginia KMP Suction Line Accumulators The Virginia KMP suction line accumulator's purpose is to prevent excessive quantities of liquid refrigerant and oil from returning to the compressor.

More information

ELMO-G Vacuum Pumps/Compressors, Range 2BH1, Three-Phase 50 Hz

ELMO-G Vacuum Pumps/Compressors, Range 2BH1, Three-Phase 50 Hz ELMO- Vacuum Pumps/Compressors, Range 2BH1, Three-Phase 50 Hz Selection diagram vacuum operation Selection diagram compressor operation The performance curves are valid for pumping air at 15 C at the inlet

More information

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006% ATEX documenting multifunction calibrator with high accuracy 0.006% is the top instrument of our range of ATEX documenting multifunction calibrators. Description is the top instrument of our range of ATEX

More information

Finnigan TC/EA. High Temperature Conversion Elemental Analyzer

Finnigan TC/EA. High Temperature Conversion Elemental Analyzer m a s s s p e c t r o m e t r y Finnigan TC/EA High Temperature Conversion Elemental Analyzer Analyze Detect Measure Control Finnigan TC/EA High Temperature Conversion Elemental Analyzer Finnigan TC/EA

More information

AC axial compact fan

AC axial compact fan ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA 59

More information

Working pressure. 420 bar. Style T. Style B. Style D Style V Style Z. Style S B B D.I. D.I. D.I. D.I. D.I. D.I.

Working pressure. 420 bar. Style T. Style B. Style D Style V Style Z. Style S B B D.I. D.I. D.I. D.I. D.I. D.I. 5 FP SRIS FP Working pressure 40 bar Style S Style Style T Style D Style V Style Z 5 Technical data Filter body (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment)

More information

Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate

Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate Technical specification FLUXUS F502TE Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate Stationary ultrasonic clamp-on system for

More information

CoriolisMaster FCB430, FCB450, FCH430, FCH450 Coriolis mass flowmeter

CoriolisMaster FCB430, FCB450, FCH430, FCH450 Coriolis mass flowmeter Data Sheet DS/FCB400/FCH400-EN Rev. D CoriolisMaster FCB430, FCB450, FCH430, FCH450 Coriolis mass flowmeter High precision measurement of mass and volume flow, density, temperature and concentration with

More information

CHINA MP FILTRI P.O. Box Shanghai Phone: Fax:

CHINA MP FILTRI P.O. Box Shanghai Phone: Fax: FMP 038 uk 6-07-006 9:34 Pagina (,) New Headquarters : MP FILTRI S.p.A. Italy Via Maggio, n. 3 0060 Pessano con Bornago (Milano) Italy Tel. +39.0/95703. Fax +39.0/9574497-9574088 email: sales@mpfiltri.com

More information

Product Data. Brüel & Kjær B. Sound Intensity Calibrator Type 3541

Product Data. Brüel & Kjær B. Sound Intensity Calibrator Type 3541 Product Data Sound Intensity Calibrator Type 3541 USES: Sound intensity and particle velocity calibrations Sound pressure calibration Measurement of pressure-residual intensity index FEATURES: Intensity

More information

tekcor TKC Multivariable Coriolis Flow Sensors

tekcor TKC Multivariable Coriolis Flow Sensors Sensing the pulse of industry Technical Data Sheet & General Specifications tekcor TKC Multivariable Coriolis Flow Sensors The tekcor TKC Series principle was initiated by tekflo sensors engineers, who

More information

PHT4NQ10LT. 1. Description. 2. Features. 3. Applications. 4. Pinning information. N-channel enhancement mode field-effect transistor

PHT4NQ10LT. 1. Description. 2. Features. 3. Applications. 4. Pinning information. N-channel enhancement mode field-effect transistor MD87 Rev. September Product specification. Description in a plastic package using TrenchMOS technology. Product availability: in SOT.. Features TrenchMOS technology Fast switching Low on-state resistance

More information

READY TO SCRAP: HOW MANY VESSELS AT DEMOLITION VALUE?

READY TO SCRAP: HOW MANY VESSELS AT DEMOLITION VALUE? READY TO SCRAP: HOW MANY VESSELS AT DEMOLITION VALUE? August 206 VesselsValue Global number of vessels at demolition value At scrap value 7,27 6 Above scrap value,8 84 Number of vessels at demolition value

More information