1 V-Cone Flowmeter ATASHEET JUNHO 013

2 IntraCone Cone Flow Meter Type: ICM etail: Cone-Element Technical Information 05/011 FLOW THE SPECIALIST IN LEVEL AN FLOW

3 Cone Flow Meter Technical Information Intra-Automation ICM 1. General escription Cone Flow Meters are designed to measure the volume flow of liquids, steam and gases according to the differential pressure principle. A conical flow element is placed in the centre of a pipe line, in which the fluid to be measured is passing through. With a tap in front (flow direction) of the flow element the pipe pressure (static pressure) is measured. Passing by the element, the flow velocity raises and generates an under-pressure behind the cone, where the second tap is located. The two measured pressure values are to be compared. The outcome is called differential pressure. With this differential pressure now the flow can be calculated.. Main Features - Cone Flow Meters can be used in a great variety of applications: liquids, gases, steam, slurries etc. - High accuracy ( 0,5 % of the measured value) is achievable - Wide Turndown Ratio: 10:1 - Minimal in- and outlet requirements, provided by a pipe run. - Low pressure loss (compared with orifice plates of the same ) - Self-cleaning (due to the form of the cone behind the flow element a partial vacuum is generated, which avoids abrasion on the flow element. 3. Equations Beta ratio: Area ratio: Outside diameter of cone: ifferential pressure: d d m d * cone P P H P L Where: : Equivalent diameter ratio : Inside diameter of pipe d : iameter of largest cross section of cone q v : Volumetric Flow rate : Operating density K : K-factor : Expansion factor of gas m : Area ratio P : ifferential pressure Volumetric flow: q v K * P 4. Technical ata Standard Accuracy 0,5 % of actual flow Standard repeatablitity < 0,1 % Flow Ranges 10:1 and greater Standard Beta ratios 0,45 to 0,80 Head Loss epending on beta ratio and P Installation Piping Requirements 3 upstream 1 downstream (depending on installation situation) Materials of Construction uplex 05, 304SS, 316SS, Hastelloy C76, 54, SMO, carbon steels (other materials also available, on request) Line Sizes mm (or larger, on request) End Fittings Flanged, threaded, hub or welding ends (others on request) Op. Temperature (max.) Op. Pressure (max.) Configurations +19 F (+700 C) (higher temperatures on request) 4 MPa (40 bar) Precision flow tube - custom calibrated for customer needs - ASME construction available - 3 -

4 Intra-Automation Technical Information Cone Flow Meter ICM Flow irection Total length L: Pipe size L (mm) L (inch) N N 40 1 ½ N N 65 ½ N N N N N N N N N N N Up- and downstream pipe requirements (in multiples of outside pipe diameter []): Size All sizes isturbing Part Gas measurement Water measurement Upstream ownstream Upstream ownstream 1 Elbow Elbows T connection pipe Butterfly valve (Control valve) Butterfly valve (Cut-off valve) Ball valve (Cut off Heat exchange (acc. to type) Thermal converter (Special order) iverging duct (0,67-)length,5 iverging duct (3-1)length 3,5 10 for unfavourable position 5 for downstream of valve 3 for unfavourable position 3 for downstream of valve n/a n/a n/a n/a

5 Contactos/Contacts: Comercial/Commercial: Fernando Mena Costa Tel: (+351) Fax: (+351) Assistência/Service: Patricia Costa ppcosta@bhb.pt Tel: (+351)

Integral V-Cone Flowmeter VD series

Integral V-Cone Flowmeter VD series TRANSMITTER DIRECTLY MOUNTED! SIMPLE AND EASY INSTALLATION Integral V-Cone Flowmeter VD series OUTLINE VD series Integral V-Cone Flowmeter is a differential pressure type flowmeter. Unlikely to existing

More information

Experiment No.4: Flow through Venturi meter. Background and Theory

Experiment No.4: Flow through Venturi meter. Background and Theory Experiment No.4: Flow through Venturi meter Background and Theory Introduction Flow meters are used in the industry to measure the volumetric flow rate of fluids. Differential pressure type flow meters

More information

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book and Flow Handbook www.rosemount.com 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book NOTICE Read

More information

Flow Measurement in Pipes and Ducts COURSE CONTENT

Flow Measurement in Pipes and Ducts COURSE CONTENT Flow Measurement in Pipes and Ducts Dr. Harlan H. Bengtson, P.E. COURSE CONTENT 1. Introduction This course is about measurement of the flow rate of a fluid flowing under pressure in a closed conduit.

More information

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook Reference Manual 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book and Flow Handbook www.rosemount.com Reference Manual 405 and 1595 405 Compact Orifice Series and 1595 Conditioning

More information

Smart DP Flow Metering A summary of Established Technology and Latest Innovation. Gary Fish

Smart DP Flow Metering A summary of Established Technology and Latest Innovation. Gary Fish Smart DP Flow Metering A summary of Established Technology and Latest Innovation Gary Fish DP Flow Measurement Established Technology Large range of line sizes, materials, connection interfaces, etc Customised

More information

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,

More information

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book and Flow Handbook www.rosemount.com 405 and 1595 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test

More information

Target Insertion Flowmeter

Target Insertion Flowmeter Principle of Operation Flow is measured in terms of dynamic force acting on a target (solid disk) in the flow stream. Hermetically sealed, bonded strain gages in a bridge circuit configuration mounted

More information

SELECCIÓN DE CAUDALIMETROS. Tablas de Fabricantes

SELECCIÓN DE CAUDALIMETROS. Tablas de Fabricantes SELECCIÓN DE CAUDALIMETROS Tablas de Fabricantes Flow Meter Selection Table http://www.instrumart.com/content.aspxcontentid=219 Página 1 de 1 17/09/2007 KEY Best for this application OK with some exceptions

More information

Computation of pressure loss for differential producing flowmeters

Computation of pressure loss for differential producing flowmeters XXVI. ASR '00 Seminar, Instruments and Control, Ostrava, April 6-7, 00 Paper 5 Computation of pressure loss for differential producing flowmeters ORLÍKOVÁ, Soňa Ing., Ústav automatizace a měřicí techniky,

More information

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,

More information

Orifice Plate. Stainless Steel. Flow Data. Herz Valves UK Ltd.

Orifice Plate. Stainless Steel. Flow Data. Herz Valves UK Ltd. Stainless Steel Orifice Plate Flow Data In this flow data manual we have endeavoured to make the information as accurate as possible. We cannot accept any responsibility should it be found that in any

More information

Experiment (4): Flow measurement

Experiment (4): Flow measurement Experiment (4): Flow measurement Introduction: The flow measuring apparatus is used to familiarize the students with typical methods of flow measurement of an incompressible fluid and, at the same time

More information

FLOW MEASUREMENT. INC 102 Fundamental of Instrumentation and Process Control 2/2560

FLOW MEASUREMENT. INC 102 Fundamental of Instrumentation and Process Control 2/2560 FLOW MEASUREMENT INC 102 Fundamental of Instrumentation and Process Control 2/2560 TABLE OF CONTENTS A. INTRODUCTION B. LOCAL FLOW MEASUREMENT B.1 Particle Image Velocimetry (PIV) B.2 Laser doppler anemometry

More information

FXP DATASHEET JUNHO 2013

FXP DATASHEET JUNHO 2013 FXP DATASHEET JUNHO 01 Data Sheet D1S0U0 Rev. 0. FXP000 (PARTI-MAG II) Electromagnetic Flowmeter Model DP1F and DPF Measurement made easy For full and partially full pipelines (free and surface pipelines)

More information

Lecture23. Flowmeter Design.

Lecture23. Flowmeter Design. Lecture23 Flowmeter Design. Contents of lecture Design of flowmeter Principles of flow measurement; i) Venturi and ii) Orifice meter and nozzle Relationship between flow rate and pressure drop Relation

More information

COURSE CODE : 3072 COURSE CATEGORY : B PERIODS/ WEEK : 5 PERIODS/ SEMESTER : 75 CREDIT : 5 TIME SCHEDULE

COURSE CODE : 3072 COURSE CATEGORY : B PERIODS/ WEEK : 5 PERIODS/ SEMESTER : 75 CREDIT : 5 TIME SCHEDULE COURSE TITLE : FLUID MECHANICS COURSE CODE : 307 COURSE CATEGORY : B PERIODS/ WEEK : 5 PERIODS/ SEMESTER : 75 CREDIT : 5 TIME SCHEDULE MODULE TOPIC PERIOD 1 Properties of Fluids 0 Fluid Friction and Flow

More information

Chemical Engineering 3P04 Process Control Tutorial # 1 Learning goals

Chemical Engineering 3P04 Process Control Tutorial # 1 Learning goals Chemical Engineering 3P04 Process Control Tutorial # 1 Learning goals 1. Sensor Principles with the flow sensor example 2. The typical manipulated variable: flow through a conduit Sensors: We need them

More information

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,

More information

Flow Monitoring Technologies in Oil and Gas. Don Ford, Technical Specialist Spartan Controls Ltd.

Flow Monitoring Technologies in Oil and Gas. Don Ford, Technical Specialist Spartan Controls Ltd. Flow Monitoring Technologies in Oil and Gas Don Ford, Technical Specialist Spartan Controls Ltd. Agenda Flow technologies at a glance Oil and Gas at a glance Select Flow Technologies in Depth Differential

More information

Coriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM

Coriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM MAXIFO TM Features MaxiFlo Coriolis Mass Flowmeter series MCM is a mass flow meter that measures mass flow, density and temperature of liquids, slurries and gases. And it even measures oil content in water.

More information

MCE380: Measurements and Instrumentation Lab

MCE380: Measurements and Instrumentation Lab MCE380: Measurements and Instrumentation Lab Chapter 8: Flow Measurements Topics: Basic Flow Equations Flow Obstruction Meters Positive Displacement Flowmeters Other Methods Holman, Ch. 7 Cleveland State

More information

Flow Measurement in Pipes and Ducts COURSE CONTENT

Flow Measurement in Pipes and Ducts COURSE CONTENT Flow Measurement in Pipes and Ducts Dr. Harlan H. Bengtson, P.E. COURSE CONTENT 1. Introduction This course is about measurement of the flow rate of a fluid flowing under pressure in a closed conduit.

More information

SAMPLE SHEET. Supply of PF Process Calculation Spreadsheet (Excel Forma)

SAMPLE SHEET. Supply of PF Process Calculation Spreadsheet (Excel Forma) PROJECT NO. PO. 4500098732 / 10 / 01.01.2018 Supply of PF Process Calculation Spreadsheet (Excel Forma) DOCUMENT TITLE Small Bore Orifice Sizing Calculation For Gas Services as per ASME-MFC-14M-2001 DATE

More information

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement

More information

Instrumentation & Data Acquisition Systems

Instrumentation & Data Acquisition Systems Instrumentation & Data Acquisition Systems Section 5 -Flow Robert W. Harrison, PE Bob@TheHarrisonHouse.com Made in USA 1 The Perfect Flowmeter Infinite rangeability / turndown with negligible uncertainty

More information

POWER UNDERSTANDING MEASUREMENT UNCERTAINTY IN DP FLOW DEVICES

POWER UNDERSTANDING MEASUREMENT UNCERTAINTY IN DP FLOW DEVICES Proceedings of the ASME 2014 Power Conference POWER2014 July 28-31, 2014, Baltimore, Maryland, USA POWER2014-32205 UNDERSTANDING MEASUREMENT UNCERTAINTY IN DP FLOW DEVICES Michael S. Hering Rosemount DP

More information

Laboratory work No 2: Calibration of Orifice Flow Meter

Laboratory work No 2: Calibration of Orifice Flow Meter Laboratory work No : Calibration of Orifice Flow Meter 1. Objective Calibrate the orifice flow meter and draw the graphs p = f 1 (Q) and C d = f (Re ).. Necessary equipment 1. Orifice flow meter. Measuring

More information

Differential Pressure Producing Flow Elements

Differential Pressure Producing Flow Elements Differential Pressure Producing Flow Elements Standards Certification Education & Training Publishing Conferences & Exhibits Fort McMurray, Alberta Differential Pressure Devices for Liquid and Gas Flow

More information

04/01/1998 Developments in DP Flowmeters By Jesse Yoder

04/01/1998 Developments in DP Flowmeters By Jesse Yoder 04/01/1998 Developments in DP Flowmeters By Jesse Yoder Developments in DP Flowmeters Improvements in Primary Elements Are Keeping Differential Pressure Flowmeters the First Choice for Many Process Applications

More information

NORTH SEA FLOW MEASUREMENT WORKSHOP 2004 In. St Andrews, Scotland

NORTH SEA FLOW MEASUREMENT WORKSHOP 2004 In. St Andrews, Scotland NORTH SEA FLOW MEASUREMENT WORKSHOP 2004 In St Andrews, Scotland From the 26 th to 28 th October, 2004 Tests of the V-Cone Flow Meter at Southwest Research Institute and Utah State University in Accordance

More information

Flow Measurement in Pipes and Ducts

Flow Measurement in Pipes and Ducts Flow Measurement in Pipes and Ducts Course No: M04-040 Credit: 4 PDH Harlan H. Bengtson, Ph.D., P.E. Continuing Education and Development, Inc. 9 Greyridge Farm Court Stony Point, NY 10980 P: (877) 322-5800

More information

FLUID MECHANICS D203 SAE SOLUTIONS TUTORIAL 2 APPLICATIONS OF BERNOULLI SELF ASSESSMENT EXERCISE 1

FLUID MECHANICS D203 SAE SOLUTIONS TUTORIAL 2 APPLICATIONS OF BERNOULLI SELF ASSESSMENT EXERCISE 1 FLUID MECHANICS D203 SAE SOLUTIONS TUTORIAL 2 APPLICATIONS OF BERNOULLI SELF ASSESSMENT EXERCISE 1 1. A pipe 100 mm bore diameter carries oil of density 900 kg/m3 at a rate of 4 kg/s. The pipe reduces

More information

CHAPTER (13) FLOW MEASUREMENTS

CHAPTER (13) FLOW MEASUREMENTS CHAPTER (13) FLOW MEASUREMENTS 09/12/2010 Dr. Munzer Ebaid 1 Instruments for the Measurements of Flow Rate 1. Direct Methods: Volume or weight measurements. 2. Indirect Methods: Venturi meters, Orifices

More information

CORIOLIS MASS FLOW METERS FOR GAS AND LIQUID MEASUREMENT. Michael Keilty (Presented by Hubbard Donald) Endress + Hauser Flowtec AG

CORIOLIS MASS FLOW METERS FOR GAS AND LIQUID MEASUREMENT. Michael Keilty (Presented by Hubbard Donald) Endress + Hauser Flowtec AG Introduction CORIOLIS MASS FLOW METERS FOR GAS AND LIQUID MEASUREMENT Michael Keilty (Presented by Hubbard Donald) Endress + Hauser Flowtec AG A mass flowmeter is a system that provides a measurement of

More information

Annubar Primary Element Flow Calculations

Annubar Primary Element Flow Calculations Rosemount 485 Annubar Annubar Primary Element Flow Calculations ANNUBAR PRIMARY ELEMENT FLOW EQUATIONS The Annubar primary element flow equations are all derived from the hydraulic equations which are

More information

Applied Fluid Mechanics

Applied Fluid Mechanics Applied Fluid Mechanics 1. The Nature of Fluid and the Study of Fluid Mechanics 2. Viscosity of Fluid 3. Pressure Measurement 4. Forces Due to Static Fluid 5. Buoyancy and Stability 6. Flow of Fluid and

More information

Applied Fluid Mechanics

Applied Fluid Mechanics Applied Fluid Mechanics 1. The Nature of Fluid and the Study of Fluid Mechanics 2. Viscosity of Fluid 3. Pressure Measurement 4. Forces Due to Static Fluid 5. Buoyancy and Stability 6. Flow of Fluid and

More information

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181 Siemens AG 09 SITRANS F flowmeters System information Overview Siemens offers two types of ultrasonic flowmeters, in-line flowmeters and clamp-on flowmeters. This offers the end user the maximum flexibility

More information

GS4000 DATASHEET JUNHO 2013

GS4000 DATASHEET JUNHO 2013 GS4000 DATASHEET JUNHO 2013 www.severntrentservices.com Biochem T70GS4000 Chlorine Dioxide Generator - 2g/day - 10g/h System Advantages Dosage Flexibility The generator produces a chlorine dioxide solution,

More information

Hydraulics and hydrology

Hydraulics and hydrology Hydraulics and hydrology - project exercises - Class 4 and 5 Pipe flow Discharge (Q) (called also as the volume flow rate) is the volume of fluid that passes through an area per unit time. The discharge

More information

About the Calibration of Rotameter

About the Calibration of Rotameter About the Calibration of Rotameter IVANOV Valentin Ganchev Technical University of Sofia, Bulgaria, vgi@tu-sofia.bg Abstract This work on basis of literary studies and analysis of the author are examined

More information

Thermostatic expansion valves TUA/TUAE

Thermostatic expansion valves TUA/TUAE MAKING MODERN LIVING POSSIBLE Technical brochure Thermostatic expansion valves A/AE www.danfoss.com Thermostatic expansion valves, type A/AE Contents Page Introduction... Features... Standard range...

More information

Size : Ends : Min Temperature : Max Temperature : Materials : Brass

Size : Ends : Min Temperature : Max Temperature : Materials : Brass Size : Ends : Min Temperature : Max Temperature : DN 1/2" to 1 Free nut BSP, male or female - 10 C + 120 C Max Pressure : 20 Bars Specifications : Before or after water meter PTFE packing With free nut

More information

Mechanical Measurements and Metrology Prof. S. P. Venkateshan Department of Mechanical Engineering Indian Institute of Technology, Madras

Mechanical Measurements and Metrology Prof. S. P. Venkateshan Department of Mechanical Engineering Indian Institute of Technology, Madras Mechanical Measurements and Metrology Prof. S. P. Venkateshan Department of Mechanical Engineering Indian Institute of Technology, Madras Module - 3 Lecture - 33 Measurement of Volume and Mass Flow Rate

More information

QUALIFICATION OF FLOW CONDTIONING DEVICES ACCORDING TO THE NEW API 14.3 PART 2 PROCEDURE. Klaus J. Zanker and Dale Goodson. Daniel Industries, Inc.

QUALIFICATION OF FLOW CONDTIONING DEVICES ACCORDING TO THE NEW API 14.3 PART 2 PROCEDURE. Klaus J. Zanker and Dale Goodson. Daniel Industries, Inc. QUALIFICATION OF FLOW CONDTIONING DEVICES ACCORDING TO THE NEW API 14.3 PART 2 PROCEDURE. Klaus J. Zanker and Dale Goodson Daniel Industries, Inc. Old Tube Bundle A D a 1. a/d < 1/4 2. L/a > 1 3. A < 1/16(π

More information

FLOW MEASUREMENT IN PIPES EXPERIMENT

FLOW MEASUREMENT IN PIPES EXPERIMENT University of Leicester Engineering Department FLOW MEASUREMENT IN PIPES EXPERIMENT Page 1 FORMAL LABORATORY REPORT Name of the experiment: FLOW MEASUREMENT IN PIPES Author: Apollin nana chaazou Partner

More information

Volumetric Flow Measurement

Volumetric Flow Measurement Volumetric Flow Measurement TVF Series Vortex Flow Meter Xi an Tosilon Automation Co., Ltd No.299, Daqing Rd, Lianhu District, Xi'an Shaanxi, China Tel: +86-29-8823 8550 info@tosilon.com; www.tosilon.com

More information

Major and Minor Losses

Major and Minor Losses Abstract Major and Minor Losses Caitlyn Collazo, Team 2 (1:00 pm) A Technovate fluid circuit system was used to determine the pressure drop across a pipe section and across an orifice. These pressure drops

More information

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Lecture 13 Flow Measurement in Pipes. I. Introduction

Lecture 13 Flow Measurement in Pipes. I. Introduction Lecture 13 Flow Measurement in Pipes I. Introduction There are a wide variety of methods for measuring discharge and velocity in pipes, or closed conduits Many of these methods can provide very accurate

More information

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

ME332 FLUID MECHANICS LABORATORY (PART II)

ME332 FLUID MECHANICS LABORATORY (PART II) ME332 FLUID MECHANICS LABORATORY (PART II) Mihir Sen Department of Aerospace and Mechanical Engineering University of Notre Dame Notre Dame, IN 46556 Version: April 2, 2002 Contents Unit 5: Momentum transfer

More information

Model Selection 1. Process Valves. Air. Vacuum

Model Selection 1. Process Valves. Air. Vacuum Process Valves Model Selection For product specifications such as maximum operating pressure differentials and operating temperature ranges, refer to the relevent pages of each product. Air One-touch fittings

More information

Measurement of fluid flow in closed conduits

Measurement of fluid flow in closed conduits BRITISH STANDARD BS 1042-1.4: 1992 Incorporating Amendment No. 1 Measurement of fluid flow in closed conduits Part 1: Pressure differential devices Section 1.4 Guide to the use of devices specified in

More information

The Expansibility Factor Equations in ISO and ISO : Do They Deliver What They Promise?

The Expansibility Factor Equations in ISO and ISO : Do They Deliver What They Promise? The Expansibility Factor Equations in ISO 567-2 and ISO 567-4: Do They Deliver What They Promise? Michael Reader-Harris, NEL INTRODUCTION The expansibility factor equations in ISO 567-2:2003 [] and ISO

More information

Fundamentals of Flow Metering

Fundamentals of Flow Metering Technical Data Sheet 00816-0100-3031 Fundamentals of Flow Metering A reliable flow indication is dependent upon the correct measurement of A and V. If, for example, air bubbles are present in the fluid,

More information

Measurement of fluid flow in closed conduits

Measurement of fluid flow in closed conduits BRITISH STANDARD BS 1042-2.2: 1983 ISO 7145:1982 Measurement of fluid flow in closed conduits Part 2: Velocity area methods Section 2.2 Method of measurement of velocity at one point of a conduit of circular

More information

P & I Design Limited. 2 Reed Street, Gladstone Industrial Estate, Thornaby, TS17 7AF. Tel: +44 (0) Fax: +44 (0)

P & I Design Limited. 2 Reed Street, Gladstone Industrial Estate, Thornaby, TS17 7AF. Tel: +44 (0) Fax: +44 (0) ump Sizing & Rating USER MANUAL & I Design Limited Reed Street, Gladstone Industrial Estate, Thornaby, TS7 7AF. Tel: +44 (0) 64 67444 Fax: +44 (0) 64 66447 www.pidesign.co.uk Support: sales@pidesign.co.uk

More information

EXPERIMENT NO. 4 CALIBRATION OF AN ORIFICE PLATE FLOWMETER MECHANICAL ENGINEERING DEPARTMENT KING SAUD UNIVERSITY RIYADH

EXPERIMENT NO. 4 CALIBRATION OF AN ORIFICE PLATE FLOWMETER MECHANICAL ENGINEERING DEPARTMENT KING SAUD UNIVERSITY RIYADH EXPERIMENT NO. 4 CALIBRATION OF AN ORIFICE PLATE FLOWMETER MECHANICAL ENGINEERING DEPARTMENT KING SAUD UNIVERSITY RIYADH Submitted By: ABDULLAH IBN ABDULRAHMAN ID: 13456789 GROUP A EXPERIMENT PERFORMED

More information

Applicable Fluid. Accuracy. Flow Rate Range. Fluid Temperature. Fluid Viscosity. Connection Size. Flange Rating. Housing. Material. Blade.

Applicable Fluid. Accuracy. Flow Rate Range. Fluid Temperature. Fluid Viscosity. Connection Size. Flange Rating. Housing. Material. Blade. TOKICO TURINE METER GS-F211E- Overview Turbine meter has an excellent performance with its distinctive structure. Comparing with the flow meter using other method, it has compact and lighter design and

More information

Process Gas Flow Measurement and Performance Evaluation API TECHNICAL REPORT 2571 SECOND EDITION DRAFT, FEBRUARY 2018

Process Gas Flow Measurement and Performance Evaluation API TECHNICAL REPORT 2571 SECOND EDITION DRAFT, FEBRUARY 2018 Process Gas Flow Measurement and Performance Evaluation API TECHNICAL REPORT 2571 SECOND EDITION DRAFT, FEBRUARY 2018 (Note: modify document as needed once final proposal on name change is agreed, i.e.

More information

MAKING MODERN LIVING POSSIBLE. Thermostatic expansion valve Type TUB/TUBE and TUC/TUCE REFRIGERATION AND AIR CONDITIONING.

MAKING MODERN LIVING POSSIBLE. Thermostatic expansion valve Type TUB/TUBE and TUC/TUCE REFRIGERATION AND AIR CONDITIONING. MAKING MODERN LIVING POSSIBLE Thermostatic expansion valve Type B/BE and C/CE REFRIGERATION AND AIR CONDITIONING Technical leaflet Thermostatic expansion valve, type B/BE and C/CE Contents Page Introduction........................................................................................

More information

Size : Ends : Min Temperature : Max Temperature : Materials : Brass

Size : Ends : Min Temperature : Max Temperature : Materials : Brass Size : Ends : Min Temperature : Max Temperature : DN 1/2" to 1 Free nut BSP, male or female - 10 C + 120 C Max Pressure : 25 Bars Specifications : Before or after water meter PTFE packing With free nut

More information

FINAL DRAFT: October 25, 2010 API TECHNICAL REPORT FUEL GAS MEASUREMENT. FINAL DRAFT: October 25, 2010 Page 0

FINAL DRAFT: October 25, 2010 API TECHNICAL REPORT FUEL GAS MEASUREMENT. FINAL DRAFT: October 25, 2010 Page 0 FINAL DRAFT: October 25, 2010 API TECHNICAL REPORT FUEL GAS MEASUREMENT FINAL DRAFT: October 25, 2010 Page 0 Foreword Add API boiler plate FINAL DRAFT: October 25, 2010 Page 1 TABLE OF CONTENTS Introduction...

More information

DN 1/4" to 4" Male, Female BSP - 10 C C Max Pressure : 40 Bars Specifications : Anti blow-out stem PTFE packing Full bore.

DN 1/4 to 4 Male, Female BSP - 10 C C Max Pressure : 40 Bars Specifications : Anti blow-out stem PTFE packing Full bore. Size : Ends : Min Temperature : Max Temperature : DN 1/4" to 4" Male, Female BSP - 10 C + 120 C Max Pressure : 40 Bars Specifications : Anti blow-out stem PTFE packing Full bore Materials : Brass Page

More information

Model Selection 1. Process Valves

Model Selection 1. Process Valves Process Valves Model Selection For product specifications such as maximum operating pressure differentials and operating temperature ranges, refer to the relevent pages of each product. Air, Inert gas

More information

ABB Flowmeters Review of industrial processing flowmeters

ABB Flowmeters Review of industrial processing flowmeters White paper ABB Flowmeters Review of industrial processing flowmeters Understanding flowmeters and their pros and cons By Ron DiGiacomo, ABB Measurement Products One of the most critical measurements in

More information

ProPress (304 FKM) 1.3

ProPress (304 FKM) 1.3 ProPress (304 FKM) 41 ProPress (304 FKM) Viega ProPress for stainless is engineered for harsh industrial environments where the piping systems may come into contact with corrosive cleaning liquids. A complete

More information

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application Type 2657...59 DN 10 up to 80 mm; Plastic; 2/2 way dvantages/benefits ntegrated pilot valves, position feed-back and limit switches available Customized system solutions with Burkert valves & sensors With

More information

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up

More information

ABSTRACT I. INTRODUCTION

ABSTRACT I. INTRODUCTION 2016 IJSRSET Volume 2 Issue 4 Print ISSN : 2395-1990 Online ISSN : 2394-4099 Themed Section: Engineering and Technology Analysis of Compressible Effect in the Flow Metering By Orifice Plate Using Prasanna

More information

By-Pass. This voltage is proportional to the liquid level (threewire potentiometer circuit). The resistance reading can

By-Pass. This voltage is proportional to the liquid level (threewire potentiometer circuit). The resistance reading can " " ' " ' / The magnetic field which is in the ball or cylindrical floats actuates very small reed contacts through the wall of a guide tube and these pick up an uninterrupted measuring-circuit voltage

More information

Predictionof discharge coefficient of Venturimeter at low Reynolds numbers by analytical and CFD Method

Predictionof discharge coefficient of Venturimeter at low Reynolds numbers by analytical and CFD Method International Journal of Engineering and Technical Research (IJETR) ISSN: 2321-0869, Volume-3, Issue-5, May 2015 Predictionof discharge coefficient of Venturimeter at low Reynolds numbers by analytical

More information

A REVIEW OF THE V-CONE METER FOR NATURAL GAS FLOWS

A REVIEW OF THE V-CONE METER FOR NATURAL GAS FLOWS A REVIEW OF THE V-CONE METER FOR NATURAL GAS FLOWS Szabo, J.L. Winarski, C.P. Hypnar, P.R. Novacorp International Consulting Inc. Southern California Edison ABB Impell Corporation Conference: OMAE 99 June

More information

Size : Ends : Min Temperature : Max Temperature : Materials : Brass

Size : Ends : Min Temperature : Max Temperature : Materials : Brass Size : Ends : Min Temperature : Max Temperature : DN 1/2" to 2 Free nut BSP, male or female - 10 C + 120 C Max Pressure : 20 Bars up to DN1 1/2, 16 bars over Specifications : Before or after water meter

More information

DN 1/4" to 4" Male, Female BSP - 10 C C Max Pressure : 30 Bars (up to DN1") Specifications : Anti blow-out stem PTFE packing Full bore

DN 1/4 to 4 Male, Female BSP - 10 C C Max Pressure : 30 Bars (up to DN1) Specifications : Anti blow-out stem PTFE packing Full bore Size : Ends : Min Temperature : Max Temperature : DN 1/4" to 4" Male, Female BSP - 10 C + 120 C Max Pressure : 30 Bars (up to DN1") Specifications : Anti blow-out stem PTFE packing Full bore Materials

More information

MEDIDAS EN FLUIDOS. INEL 5205 Instrumentación. Monday, November 19, 12

MEDIDAS EN FLUIDOS. INEL 5205 Instrumentación. Monday, November 19, 12 MEDIDAS EN FLUIDOS INEL 5205 Instrumentación SENSORES DE PRESIÓN Unidades de Presión 1 psi! 1 lbf/in 2 = 6,894.76! Pa = 6,894.76!newton/m 2 = 68.948 10 3!bar (1 bar = 10 5 Pa) = 68.046 10 3!atm = 51.715

More information

ERRATA CRANE FLOW OF FLUIDS THROUGH VALVES, FITTINGS AND PIPE TECHNICAL PAPER NO. 410 METRIC VERSION

ERRATA CRANE FLOW OF FLUIDS THROUGH VALVES, FITTINGS AND PIPE TECHNICAL PAPER NO. 410 METRIC VERSION ERRATA CRANE FLOW OF FLUIDS THROUGH VALVES, FITTINGS AND PIPE TECHNICAL PAPER NO. 410 METRIC VERSION CONTACT Please address questions and possible errata to solutions@flowoffluids.com FRONT MATTER PAGE

More information

Universal type Port size AS13 1F-M3. M3 x 0.5 M5 x 0.8 AS23 1F-01 AS23 1F-02 AS33 1F-02 AS33 1F-03 AS43 1F-04 R 1/8 R 1/4 R 1/4 R 3/8 R 1/2

Universal type Port size AS13 1F-M3. M3 x 0.5 M5 x 0.8 AS23 1F-01 AS23 1F-02 AS33 1F-02 AS33 1F-03 AS43 1F-04 R 1/8 R 1/4 R 1/4 R 3/8 R 1/2 Minimizes installation time and cost Reduces the mounting height and enables compact machinery design. Effective area is larger than the former model. Tube swivels 0 Universal type permits 0 piping swivel.

More information

MX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E

MX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E OMPT ND USER FRIENDLY MX Series Metal Tube Type Variable rea Flowmeter OUTLINE MX Series flowmeter is the metal tube type variable area flowmeter having the unified face-to-face dimension. The compact

More information

close to performances of the turbine gas meters designed for custody transfer measurements.

close to performances of the turbine gas meters designed for custody transfer measurements. QUANTOMETER DESIGN AND FUNCTION CPT Quantometers have been designed in order to provide our customers with reliable and inexpensive measuring instruments for secondary flow measurements. Our great experience

More information

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50 /way ball valve with electric rotary actuator, ball valve in plastic, N 50 Suitable for aggressive media High flow rate value Actuator with adjustable limit switches Visual position indicator Type 0 can

More information

Flowmeter Discharge Coefficient Estimation

Flowmeter Discharge Coefficient Estimation Bankston 1 Flowmeter Discharge Coefficient Estimation Elizabeth Bankston Team 1 Abstract An Edibon FME18 Flow Meter demonstration system was used to obtain experimental values for this experiment. The

More information

Cone differential pressure flow meter. Operating manual WIDE PLUS PRECISION INSTRUMENTS CO., LTD.

Cone differential pressure flow meter. Operating manual WIDE PLUS PRECISION INSTRUMENTS CO., LTD. Cone differential pressure flow meter Operating manual WIDE PLUS PRECISION INSTRUMENTS CO., LTD. INDEX Introduction 2 Principle Application The characteristics of flow meter Specification Technical features

More information

FLOW MEASUREMENT INC 331 Industrial process measurement 2018

FLOW MEASUREMENT INC 331 Industrial process measurement 2018 FLOW MEASUREMENT INC 331 Industrial process measurement 2018 1 TABLE OF CONTENTS A. INTRODUCTION B. LOCAL FLOW MEASUREMENT B.1 Particle Image Velocimetry (PIV) B.2 Laser doppler anemometry (LDA) B.3 Hot-wire

More information

White Paper FINAL REPORT AN EVALUATION OF THE HYDRODYNAMICS MECHANISMS WHICH DRIVE THE PERFORMANCE OF THE WESTFALL STATIC MIXER.

White Paper FINAL REPORT AN EVALUATION OF THE HYDRODYNAMICS MECHANISMS WHICH DRIVE THE PERFORMANCE OF THE WESTFALL STATIC MIXER. White Paper FINAL REPORT AN EVALUATION OF THE HYDRODYNAMICS MECHANISMS WHICH DRIVE THE PERFORMANCE OF THE WESTFALL STATIC MIXER Prepared by: Dr. Thomas J. Gieseke NUWCDIVNPT - Code 8233 March 29, 1999

More information

2/3 Port Valves for Fluid Control Model Selection 1

2/3 Port Valves for Fluid Control Model Selection 1 / Port Valves for Control Model Selection Model Selection For product specifications such as maximum operating pressure differentials and operating temperature ranges, refer to the relevent pages of each

More information

Thermostatic expansion valves TUB/TUBE and TUC/TUCE

Thermostatic expansion valves TUB/TUBE and TUC/TUCE MAKING MODERN LIVING POSSIBLE Technical brochure Thermostatic expansion valves B/BE and C/CE www.danfoss.com Thermostatic expansion valve, type B/BE and C/CE Contents Page Introduction........................................................................................

More information

Use N 1, if sizing the valve for a flow rate in volumetric units (gpm or m 3 /h).

Use N 1, if sizing the valve for a flow rate in volumetric units (gpm or m 3 /h). ANSI/ISA/IEC Valve Sizing Catalog 2 March 202 Page 2 Introduction Standardization activities for control valve sizing can be traced back to the early 960's when an American trade association, the Fluids

More information

Discharge Coefficient Prediction for Multi hole Orifice Plate in a Turbulent Flow through Pipe: Experimental and Numerical Investigation

Discharge Coefficient Prediction for Multi hole Orifice Plate in a Turbulent Flow through Pipe: Experimental and Numerical Investigation Discharge Coefficient Prediction for Multi hole Orifice Plate in a Turbulent Flow through Pipe: Experimental and Numerical Investigation [] Mahendra Babu.K.J, [2] Dr. Gangadhara Gowda C.J, [3] Ranjith

More information

SMV 3000 Smart Multivariable Flow Transmitter

SMV 3000 Smart Multivariable Flow Transmitter SMV 3000 Smart Multivariable Flow Transmitter Measurements and Calculations: Differential Pressure Absolute or Gauge Pressure Process Temperature via 100 ohm Pt. RTD or Type J,K,T or E Thermocouple Mass

More information

DELTA FLOWMETER FOR GAS SERVICE (INSERTION TYPE) MODEL VF SERIES

DELTA FLOWMETER FOR GAS SERVICE (INSERTION TYPE) MODEL VF SERIES DETA FOWMETER FOR GAS SERVICE (INSERTION TYPE) MODE VF SERIES GENERA SPECIFICATION GS. No. GBD0-0-E GENERA In the thermistor type Delta meter, a probe inserted in the pipeline detects the representative

More information

DETERMINATION OF DISCHARGE AND HEAD LOSS USING A FLOW-MEASURING APPARATUS

DETERMINATION OF DISCHARGE AND HEAD LOSS USING A FLOW-MEASURING APPARATUS DETERMINATION OF DISCHARGE AND HEAD LOSS USING A FLOW-MEASURING APPARATUS 1. INTRODUCTION Through use of the Flow-Measuring Apparatus, this experiment is designed to accustom students to typical methods

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

Installation effects on an ultrasonic flow meter with implications for self diagnostics

Installation effects on an ultrasonic flow meter with implications for self diagnostics Flow Measurement and Instrumentation 11 (2000) 109 122 www.elsevier.com/locate/flowmeasinst Installation effects on an ultrasonic flow meter with implications for self diagnostics Carl Carlander *, Jerker

More information

Experimental and CFD analysis of flow through venturimeter to determine the coefficient of discharge

Experimental and CFD analysis of flow through venturimeter to determine the coefficient of discharge Experimental and CFD analysis of flow through venturimeter to determine the coefficient of discharge Nikhil Tamhankar Amar Pandhare Ashwinkumar Joglekar Vaibhav Bansode Abstract- The pressure distribution

More information

Flow Measurement: Physical principle employed in various types of flow meters. PART 4 PREPARED BY: ESO OLUWATOBILOBA

Flow Measurement: Physical principle employed in various types of flow meters. PART 4 PREPARED BY: ESO OLUWATOBILOBA Flow Measurement: Physical principle employed in various types of flow meters. PART 4 PREPARED BY: ESO OLUWATOBILOBA Pressure Differential Flow Meters In a differential pressure drop device the flow is

More information

Fluid Cooling Industrial PF Series

Fluid Cooling Industrial PF Series Fluid Cooling Industrial PF Series 0916 STAINLESS STEEL PLATES CARBON STEEL FRAME Performance Notes Carry bar Gasketed plate style heat exchanger Tie rods Oil to water applications High performance Pressure

More information