Report to Tyris Realty on a Geotechnical Investigation for a Proposed Warehouse Development at Sprite Place, Westmead

Size: px
Start display at page:

Download "Report to Tyris Realty on a Geotechnical Investigation for a Proposed Warehouse Development at Sprite Place, Westmead"

Transcription

1 Report to Tyris Realty on a Geotechnical Investigation for a Proposed Warehouse Development at Sprite Place, Westmead Reference : Dated : February 2012 MOORE SPENCE JONES (PTY) LTD Consulting Geotechnical, Environmental & Civil Engineers 2 nd Floor, Pharos House, 70 Buckingham Terrace, Westville, 3630 PO Box 1263, Wandsbeck, 3631 Tel : +27 (0) Fax : +27 (0)

2 Report to Tyris Realty on a Geotechnical Investigation for a Proposed Warehouse Development at Sprite Place, Westmead Reference : Dated : February 2012 TABLE OF CONTENTS 1. INTRODUCTION AND TERMS OF REFERENCE INFORMATION SUPPLIED SITE DESCRIPTION FIELDWORK Inspection Pits Dynamic Cone Penetrometer Tests SITE GEOLOGY GROUNDWATER LABORATORY TESTING AND MATERIALS EVALUATION Laboratory Test Results Materials Assessment DEVELOPMENT RECOMMENDATIONS Proposed Development Excavation Requirements and Trenchability Foundations Subgrade Improvement for Paved Road and Parking Areas CONCLUSIONS... 6 Appendix A : Inspection Pit Logs Appendix B : Dynamic Cone Penetrometer (Light) Test Results Appendix B : Laboratory Test Results Figure 1 Geotechnical Investigation for the Proposed Warehouse Development at Sprite Place, Westmead Contents Page 1 Path: H:\11\11-358\Reports\11-358R01.doc

3 Report to Tyris Realty on a Geotechnical Investigation for a Proposed Warehouse Development at Sprite Place, Westmead Reference : Dated : February INTRODUCTION AND TERMS OF REFERENCE Moore Spence Jones (Pty) Ltd were appointed by Mr Tyron Baird of Tyris Realty to carry out a geotechnical investigation on a proposed warehouse development at 11 Sprite Place in Westmead. Moore Spence Jones were appointed in an on 15 th December to proceed with the investigation. The investigation was carried out during mid to late, This report contains the results of the investigation carried out, and provides recommendations for earthworks, foundations, materials usage and subgrade treatment. 2. INFORMATION SUPPLIED The following information was used in the investigation: Copy of google image showing the location of the existing site layout, and Digital copy of plan prepared by Africa Edge Architects showing the layout of the proposed development 3. SITE DESCRIPTION The site for the proposed development is located at 11 Sprite Place within the Westmead Industrial Park. The site occurs at the end of a cul-de-sac access road. It comprise a large open, flat yard with a number of buildings on it. These buildings consist of offices, temporary structures, and a small workshop building. The site is used for the parking of large trucks and other vehicles. It is largely unsurfaced, and has a crushed stone wearing course. The site is bounded on the north by a sloping embankment and on all other sides by fencing and developed sites. The layout of the site is shown in detail in Figure FIELDWORK The fieldwork for the geotechnical investigation comprised the following: Inspection Pits, and Dynamic Cone Penetrometer tests. 4.1 Inspection Pits Nine inspection pits, designated IP1 through IP9, were dug by hand at the approximate positions shown in Figure 1. The inspection pits were taken to final and refusal depths ranging between 0.30 and 1.20 metres depth below existing ground level. Samples taken from the inspection pits were profiled by a geologist 1 and sent for later testing in a commercial soils laboratory. The logs are provided in Appendix A. 1 Geoterminology Workshop (2002) Guidelines for Soil and Rock Logging - SAIEG-AEG-SAICE (Geotech Div) pp47 Geotechnical Investigation for the Proposed Warehouse Development at Sprite Place, Westmead Page 1 Path: H:\11\11-358\Reports\11-358R01.doc

4 4.2 Dynamic Cone Penetrometer Tests Twelve Dynamic Cone Penetrometer (light), or DPL tests, designated DPL1 through DPL12 were carried out at the approximate positions shown on Figure 1. The DPL tests were advanced to refusal depths ranging between 0.3 and 1.8 metres below existing ground level, with the final depths as shown on Figure 1. The results of these cone penetrometer tests, consisting of plots of blowcount and inferred soil consistency against penetration depth, are given in Appendix B. 5. SITE GEOLOGY The site is underlain by fill, transported soils and weathered sandstone bedrock of the Natal Group. The results of the investigation indicate that the site consists of a cut to fill platform. The embankment bounding the site on the north comprises a deep cutting battered to approximately 1 V to 1.5H. The existing offices on the north are located in the cutting part of the platform and directly underlain by weathered bedrock comprising a maroon to pinkish brown, thinly to medium bedded, fine grained sandstone of at least very soft rock strength. Towards the south, however, the platform is located mostly on fill immediately overlying the weathered sandstone. Most of the site has a wearing course material comprising a sandy medium to coarse crushed stone gravel. The wearing course layer is on average 150mm, in the range 70 to 220 mm thick. Generally fill underlies the wearing course. The fill comprises moist orange to pinkish brown, silty and gravelly sand. This material consists mostly of the weathered sandstone taken from the cutting on the north and used to build up the platform level. The fill was observed to have a thickness in excess of 0.7 metres. Where the fill layer was penetrated it was found to be underlain by either weathered sandstone or by residual sandstone soils which consists of maroon to yellowish brown, dense intact silty sand. The results of the DPL tests indicate that the materials beneath this site are invariably fairly competent, ranging from medium dense to very dense at very shallow depths. 6. GROUNDWATER While no groundwater was encountered in any of the inspection pits put down it should be noted that the existence of the shallow bedrock under the approximate northern half of the site indicates that there is a strong potential for perched groundwater seepage to occur, particularly in the vicinity of the toe of the deep cutting on the northern boundary. 7. LABORATORY TESTING AND MATERIALS EVALUATION 7.1 Laboratory Test Results Laboratory tests, comprising Indicator tests, were scheduled on soil samples recovered from the site. The tests comprised the following: Indicator tests comprising particle size distribution and Atterberg Limits, and Modified AAHSTO and California Bearing Ratio (CBR) tests The laboratory test results are summarised in Table 1 below and the detailed test results are included in Appendix C. Geotechnical Investigation for the Proposed Warehouse Development at Sprite Place, Westmead Page 2 Path: H:\11\11-358\Reports\11-358R01.doc

5 Table 1 Summary of Results of Particle Size Distribution Analysis, Atterberg Limit Determinations and CBR tests IP No. Depth (m) IP IP IP IP IP Description Particle Size % Atterberg Limits Modified AASHTO CBR Values (%) Compaction MDD (%) Swell (%) Classification and Activity Clay Silt Sand Gravel LL PI LS % GM MDD (kg/m³) OMC % Blue grey to grey brown SP A-1-b(0); G5 coarse GRAVEL Light pink brown silty NP A-2-4(0); <G10 SAND. Fill. Light pink brown silty SP A-2-4(0); SAND. Fill. G9/G10 Light pink brown silty SP A-2-4(0); <G10 SAND. Fill. Yellow brown stained A-2-4(0); orange silty SAND. G8/G9 Residual sandstone. LL - Liquid Limit GM - Grading Modulus Classification in Terms of: USPRA PI - Plasticity Index MDD - Maximum Dry Density TRH14 (1985) LS - Linear Shrinkage OMC - Optimum Moisture Content Unified Soil Classification System Geotechnical Investigation for the Proposed Warehouse Development at Sprite Place, Westmead Page 3 Path: H:\11\11-358\Reports\11-358R01.doc

6 7.2 Materials Assessment The following can be concluded from the laboratory test results above regarding the material classification, subgrade quality and materials usage of the materials on site: Wearing course Sandy coarse crushed rock GRAVEL Silty SAND to SAND. Table 2 Materials Classification and Usage Material Type Classification Usage Silt and Clay = 14% PI = SP GM = 2.05 Fill Light pinkish brown to maroon silty SAND Residual and Weathered Sandstone Light pinkish brown to maroon silty SAND CBR = 95% MDD A-1-B(0); G5 (TRH14:1985). Silt and Clay = 15 to 32% PI = NP to SP GM = 0.88 to 1.45 CBR = 5 to 90% MDD CBR = 6 to 93% MDD CBR = 6 to 95% MDD CBR swell =1.17 to 4.68% at 100% % MDD. A-2-4(0); ranges from <G10 to G9. Silt and Clay = 25% PI = 4 GM = 1.45 CBR = 90% MDD CBR = 93% MDD CBR = 95% MDD CBR swell = 0.47% at 100% MDD. A-2-4(0); G8 Excellent subbase material - G5 quality. Suitable for later use in the construction of subbase/base course layer of proposed paved area. Will respond well to cement stabilisation (say 4% by mass), to yield at least C4 quality stabilised material (TRH14:1985). Generally poor to very poor subgrade material marginally suitable for use in bulk fills. Although classifying as A-2-4(0) and therefore a generally sandy material, this material has characteristic very high CBR swell values which makes it very sensitive to moisture changes. Likely to give compaction problems during construction. It is advisable to undercut this material where it occurs beneath paved areas and to replace it with good quality material either imported or borrowed from elsewhere on site, such as the G5 wearing course material. While this result indicates a fair to good subgrade material one can expect the same quality of material as for the fill materials above which are taken from the cutting on the north i.e. generally poor to very poor subgrade material marginally suitable for use in bulk fills,. Large variability in quality can be expected and although classifying as A-2-4(0), this material has characteristic very high CBR swell values which makes it very sensitive to moisture changes. Likely to give compaction problems during construction. It is advisable to undercut this material where it occurs beneath paved areas and to replace it with good quality material either imported or borrowed from elsewhere on site, such as the G5 wearing course material. 8. DEVELOPMENT RECOMMENDATIONS 8.1 Proposed Development No detailed information regarding the development has been provided, other than it will comprise a vehicle storage yard (much as it is at present), with a new two storey administration and warehouse building on the north-eastern corner of the site. This building will be stepped up the existing cutting on the northern boundary. It is assumed that the part of the site will be paved, although the nature of the paving (interlock block, concrete or asphalt) is still to be decided. Geotechnical Investigation for the Proposed Warehouse Development at Sprite Place, Westmead Page 4 Path: H:\11\11-358\Reports\11-358R01.doc

7 8.2 Excavation Requirements and Trenchability While the inspection pits and the DPL tests refused at relatively shallow depth of between 0.3 and 1.8 metres below existing ground level, and therefore consist of Soft Excavation (SABS 1200DM), it is considered that from an average depth of 1.2 metres the sandstone bedrock should be considered as Intermediate Excavation material (SABS 1200DM) becoming Hard Excavation with depth fairly rapidly. The sandstone is likely to improve in strength with corresponding reduction in weathering grade with depth and this should be taken into account. An allowance for heavy ripping or trenching i.e. Hard Excavation, should be made below a depth of about 1.5 metres. Given the generally competent nature of the ground beneath this site excavations with vertical sidewalls advanced to a depth of 2.0 metres should remain stable for at least 24 hours unless affected by rainy weather. 8.3 Foundations While no foundation loads and structural information regarding the various structures were available at the time this geotechnical investigation was carried out, the results of the geotechnical investigation indicate that the founding conditions beneath the site are generally favourable for the use of shallow conventional footings. Provided foundations are advanced into the residual soils or weathered sandstone of at least dense consistency a maximum allowable bearing pressure of 150 kpa may be adopted for shallow footings founded at a depth not less than 1.2 metres below existing ground level. Provided this is adhered to differential settlement will be less than 5mm. Foundations may also be placed in the fill materials of medium dense to dense consistency where an allowable bearing pressure of 120 may be adopted, but this must be confirmed subject to inspections carried out by Moore Spence Jones. It is also recommended that a DPL test be done at each footing position to confirm the nature and consistency of the fill materials with depth. In any event, it is recommended that all foundation excavations be inspected by Moore Spence Jones to confirm depth of founding and bearing pressure. 8.4 Subgrade Improvement for Paved Road and Parking Areas Discussions with the Structural Engineer of the project, Mr Mike Slabbert, indicate that only parts of the hardstand on the site will be paved. The site will be used to park and marshal container trucks with trailers. The paving is likely to consist of interlock block paving, although alternatives are also under consideration. The existence of the fill and residual soil subgrade beneath the crushed stone is a cause of concern since although these materials are A-2-4(0) and occasionally up to G9 in quality they are often less than G10 in quality because of very high CBR swell values. These high CBR swells are attributed to the composition of the soils containing a high interstitial mica content which absorbs water readily. The net result is that when the soils wet up they swell and lose their shear strength, resulting in poor subgrade conditions, and becoming impassable to vehicles. This problem has been noted at the site before after wet periods, according to Mr Slabbert. The use of interlock block paving will require a stabilised subbase to minimise water ingress into the insitu subgrade soils. The alternatives for subgrade improvement that may be considered are as follows: The poor subgrade soils should be undercut to some depth below top of subgrade level and replaced with a good quality granular material. The depth required will need to be determined by the road designer. A crushed stone (G2) material is advisable since it has a high strength and will limit the undercut requirement to between 300 and 500mm Geotechnical Investigation for the Proposed Warehouse Development at Sprite Place, Westmead Page 5 Path: H:\11\11-358\Reports\11-358R01.doc

8 Alternatively, given that the site already has a good quality gravel wearing course (G5 quality) at surface, the thickness of this layer can be supplemented with additional crushed stone gravel (preferably G2) placed on top of the existing surface, Other important considerations to promote the life of the paved areas are the following: The entire platform design must incorporate an integrated stormwater management plan, incorporating appropriate falls and drainage channels to prevent standing water from occurring. Given the anticipation that shallow groundwater will be problematic where the shallow bedrock is most prolific in the northern half of the platform, the inclusion of subsoil drainage should be allowed for to protect the pavement layers from water ingress. 9. CONCLUSIONS This report presents and discusses the results of a geotechnical investigation carried out for the proposed warehouse development at 11 Sprite Place in Westmead. It also provides recommendations for foundations, excavations, materials usage, drainage and subgrade preparation. The site is located on a large cut to fill platform with the northern half of the site situated in shallow sandstone bedrock of the Natal Group. Towards the south the site is underlain by a relatively thin layer of fill overlying the sandstone or residual sandstone. Finally, the information given in this report relates specifically to the positions of the inspection pits and dynamic cone penetrometer tests carried out on this site. Variations in geological conditions may be encountered elsewhere on site during construction. As a result the construction phase of the project should be regarded as part of the geotechnical investigation and Moore Spence Jones consulted when ground conditions vary from those given thin this report. MOORE SPENCE JONES (PTY) LTD Consulting Geotechnical, Environmental & Civil Engineers 2 nd Floor, Pharos House, 70 Buckingham Terrace, Westville, 3630 PO Box 1263, Wandsbeck, 3631 Tel : +27 (0) Fax : +27 (0) Geotechnical Investigation for the Proposed Warehouse Development at Sprite Place, Westmead Page 6 Path: H:\11\11-358\Reports\11-358R01.doc

9 APPENDIX A Geotechnical Investigation for the Proposed Warehouse Development at Sprite Place, Westmead Path: H:\11\11-358\Reports\11-358R01.doc

10 TYRIS REALTY Proposed Development at Sprite Place, Westmead HOLE No: IP1 Sheet 1 of 1 JOB NUMBER: Scale S1 1: Dry blueish grey to greyish brown dense intact sandy medium to coarse GRAVEL. Crusher run. Slightly moist pinkish orangey brown dense intact silty fine grained SAND. Fill. NOTES 1) Refusal at 0.56m on very dense material (fill). 2) No groundwater seepage. 3) No sidewall collapse. 4) From 0.0 to 0.28m quarry stones abundant, fine to medium gravel, well compacted. 5) Samples taken : S m (3 x Bulk) CONTRACTOR : MACHINE : DRILLED BY : PROFILED BY : TYPE SET BY : SAS SETUP FILE : MSJA4.SET D08E MOORE SPENCE JONES (MALAWI) INCLINATION : DIAM : 09/02/12 08:24 TEXT :..\11-358\LOGS\DOTHEAD.DOC ELEVATION : X-COORD : Y-COORD : HOLE No: IP1 dotplot 6005 PBpH6

11 TYRIS REALTY Proposed Development at Sprite Place, Westmead HOLE No: IP2 Sheet 1 of 1 JOB NUMBER: S1 Scale 1: Slightly moist dark grey brown medium dense intact silty fine grained SAND. Colluvium. Moist light pinkish brown medium dense intact silty SAND. Residual arkosic sandstone/ Fill? NOTES 1) Refusal at 0.52m on hard bedrock. 2) No groundwater seepage. 3) No sidewall collapse. 4) Samples taken : S m (3 x Bulk) CONTRACTOR : MACHINE : DRILLED BY : PROFILED BY : TYPE SET BY : SAS SETUP FILE : MSJA4.SET D08E MOORE SPENCE JONES (MALAWI) INCLINATION : DIAM : 09/02/12 08:24 TEXT :..\11-358\LOGS\DOTHEAD.DOC ELEVATION : X-COORD : Y-COORD : HOLE No: IP2 dotplot 6005 PBpH6

12 TYRIS REALTY Proposed Development at Sprite Place, Westmead HOLE No: IP3 Sheet 1 of 1 JOB NUMBER: Scale 1: Dry to slightly moist blue grey to dark grey brown dense intact sandy GRAVEL. Crusher run. Slightly moist to moist pinkish orange brown dense intact silty SAND. Fill NOTES 1) Refusal at 0.73m on dense fill. 2) No groundwater seepage. 3) No sidewall collapse. 4) From 0.0 to 0.07m abundant quarry stones, well compacted. 5) From 0.07 to 0.73m residual sandstone, highly weathered fragments of very soft rock present in pebble to boulder-sized, part of fill. CONTRACTOR : MACHINE : DRILLED BY : PROFILED BY : TYPE SET BY : SAS SETUP FILE : MSJA4.SET D08E MOORE SPENCE JONES (MALAWI) INCLINATION : DIAM : 09/02/12 08:24 TEXT :..\11-358\LOGS\DOTHEAD.DOC ELEVATION : X-COORD : Y-COORD : HOLE No: IP3 dotplot 6005 PBpH6

13 TYRIS REALTY Proposed Development at Sprite Place, Westmead HOLE No: IP4 Sheet 1 of 1 JOB NUMBER: Scale 1: Slightly moist dark grey brown with blotched of blue grey dense intact sandy GRAVEL. Crusher run. Moist pinkish brown medium dense to dense intact silty SAND. Residual arkosic sandstone/ Fill? 0.87 NOTES 1) Refusal at 0.87m on dense fill material. 2) No groundwater seepage. 3) No sidewall collapse. 4) From 0.0 to 0.13m abundant quarry stones, well compacted. CONTRACTOR : MACHINE : DRILLED BY : PROFILED BY : TYPE SET BY : SAS SETUP FILE : MSJA4.SET D08E MOORE SPENCE JONES (MALAWI) INCLINATION : DIAM : 09/02/12 08:24 TEXT :..\11-358\LOGS\DOTHEAD.DOC ELEVATION : X-COORD : Y-COORD : HOLE No: IP4 dotplot 6005 PBpH6

14 TYRIS REALTY Proposed Development at Sprite Place, Westmead HOLE No: IP5 Sheet 1 of 1 JOB NUMBER: Scale 1: Slightly moist dark grey brown with blotches of blueish grey dense intact subangular sandy medium to coarse GRAVEL. Crusher run. Moist pinkish brown medium dense intact silty fine SAND. Fill. S NOTES 1) Refusal at 1.15m on dense material. 2) No groundwater seepage. 3) No sidewall collapse. 4) Samples taken : S m (3 x Bulk) CONTRACTOR : MACHINE : DRILLED BY : PROFILED BY : TYPE SET BY : SAS SETUP FILE : MSJA4.SET D08E MOORE SPENCE JONES (MALAWI) INCLINATION : DIAM : 09/02/12 08:24 TEXT :..\11-358\LOGS\DOTHEAD.DOC ELEVATION : X-COORD : Y-COORD : HOLE No: IP5 dotplot 6005 PBpH6

15 TYRIS REALTY Proposed Development at Sprite Place, Westmead HOLE No: IP6 Sheet 1 of 1 JOB NUMBER: S1 Scale 1: Slightly moist dark greyish brown with blotches of blueish grey dense intact subangular sandy medium to coarse GRAVEL. Crusher run. Moist pinkish brown medium dense to dense at depth intact silty fine grained SAND. Fill. Slightly moist to moist yellowish brown stained orange dense intact very silty fine grained SAND. Residual sandstone NOTES 1) Refusal at 1.18m on dense material. 2) No groundwater seepage. 3) No sidewall collapse. 4) Top layer is covered with quarry stone. 5) Samples taken : S m (3 x Bulk) CONTRACTOR : MACHINE : DRILLED BY : PROFILED BY : TYPE SET BY : SAS SETUP FILE : MSJA4.SET D08E MOORE SPENCE JONES (MALAWI) INCLINATION : DIAM : 09/02/12 08:24 TEXT :..\11-358\LOGS\DOTHEAD.DOC ELEVATION : X-COORD : Y-COORD : HOLE No: IP6 dotplot 6005 PBpH6

16 TYRIS REALTY Proposed Development at Sprite Place, Westmead HOLE No: IP7 Sheet 1 of 1 JOB NUMBER: Scale 1: Slightly moist dark greyish brown with blotches of blue grey dense intact subangular sandy medium to coarse GRAVEL. Crusher run. Moist pinkish brown medium dense intact silty fine to medium grained SAND. Fill Slightly moist to moist yellowish brown stained orange dense intact very silty fine grained SAND. Residual sandstone. NOTES 1) Final depth at 1.00m. 2) No groundwater seepage. 3) No sidewall collapse. CONTRACTOR : MACHINE : DRILLED BY : PROFILED BY : TYPE SET BY : SAS SETUP FILE : MSJA4.SET D08E MOORE SPENCE JONES (MALAWI) INCLINATION : DIAM : 09/02/12 08:24 TEXT :..\11-358\LOGS\DOTHEAD.DOC ELEVATION : X-COORD : Y-COORD : HOLE No: IP7 dotplot 6005 PBpH6

17 TYRIS REALTY Proposed Development at Sprite Place, Westmead HOLE No: IP8 Sheet 1 of 1 JOB NUMBER: Scale 1: Slightly moist dark greyish brown with blotches of blueish grey dense intact subangular sandy medium to coarse GRAVEL. Crusher run. Moist pinkish brown medium dense intact silty fine to medium grained SAND. Fill. Slightly moist to moist yellowish brown stained orange dense intact very silty fine grained SAND. Residual sandstone NOTES 1) Final depth at 1.20m. 2) No groundwater seepage. 3) No sidewall collapse. CONTRACTOR : MACHINE : DRILLED BY : PROFILED BY : TYPE SET BY : SAS SETUP FILE : MSJA4.SET D08E MOORE SPENCE JONES (MALAWI) INCLINATION : DIAM : 09/02/12 08:24 TEXT :..\11-358\LOGS\DOTHEAD.DOC ELEVATION : X-COORD : Y-COORD : HOLE No: IP8 dotplot 6005 PBpH6

18 TYRIS REALTY Proposed Development at Sprite Place, Westmead HOLE No: IP9 Sheet 1 of 1 JOB NUMBER: Scale 1: Slightly moist greyish brown loose intact silty medium grained SAND with abundant roots. Slightly moist pinkish brown dense intact silty fine grained SAND. Fill. NOTES 1) Refusal at 0.30m on very dense material. 2) No groundwater seepage. 3) No sidewall collapse. CONTRACTOR : MACHINE : DRILLED BY : PROFILED BY : TYPE SET BY : SAS SETUP FILE : MSJA4.SET D08E MOORE SPENCE JONES (MALAWI) INCLINATION : DIAM : 09/02/12 08:24 TEXT :..\11-358\LOGS\DOTHEAD.DOC ELEVATION : X-COORD : Y-COORD : HOLE No: IP9 dotplot 6005 PBpH6

19 APPENDIX B Geotechnical Investigation for the Proposed Warehouse Development at Sprite Place, Westmead Path: H:\11\11-358\Reports\11-358R01.doc

20 Tel: +27(0) Fax: +27(0) iafrica.com Client: TYRIS REALTY Ref.No Project: Proposed Development at Sprite Place, Westmead Date: Section: Operator: KN/YH L i g h t D y n a m i c P e n e t r o m e t e r P r o b e T e s t N o. DPL 1 L i g h t D y n a m i c P e n e t r o m e t e r P r o b e T e s t N o. DPL 2 L i g h t D y n a m i c P e n e t r o m e t e r P r o b e T e s t N o. DPL 3 THE INSITU STRENGTH DEPENDS ON SOIL MOISTURE CONTENT AND GRAIN STRUCTURE WHICH HAVE NOT BEEN ASSESSED AND MAY CHANGE. THE VALUES GIVEN ARE THEREFORE INDICATIVE ONLY AND SHOULD BE VERIFIED BY TEST OR OBSERVATION Hammer: 10kg falling 550mm C=1 Hammer: 10kg falling 550mm C=1 Hammer: 10kg falling 550mm C=1 Cone: 25mm diameter with 60 degree apex angle Phi=0 Cone: 25mm diameter with 60 degree apex angle Phi=0 Cone: 25mm diameter with 60 degree apex angle Phi=0 Depth Blows Inferred Rods: 16mm diameter, 22mm diameter couplings Depth Blows Inferred Rods: 16mm diameter, 22mm diameter couplings Depth Blows Inferred Rods: 16mm diameter, 22mm diameter couplings metres per 300mm Consistency metres per 300mm Consistency metres per 300mm Consistency Loose Med.Dense Very Loose Very Dense -0.6 Ref Med.Dense -0.6 Ref Med.Dense Dense -1.2 Ref Depth (m) Depth (m) Depth (m) Blows per 300mm Blows per 300mm Blows per 300mm H:\11\11-358\DPL\DPL1-3

21 Tel: +27(0) Fax: +27(0) iafrica.com Client: TYRIS REALTY Ref.No Project: Proposed Development at Sprite Place, Westmead Date: Section: Operator: KN/YH L i g h t D y n a m i c P e n e t r o m e t e r P r o b e T e s t N o. DPL 4 L i g h t D y n a m i c P e n e t r o m e t e r P r o b e T e s t N o. DPL 5 L i g h t D y n a m i c P e n e t r o m e t e r P r o b e T e s t N o. DPL 6 THE INSITU STRENGTH DEPENDS ON SOIL MOISTURE CONTENT AND GRAIN STRUCTURE WHICH HAVE NOT BEEN ASSESSED AND MAY CHANGE. THE VALUES GIVEN ARE THEREFORE INDICATIVE ONLY AND SHOULD BE VERIFIED BY TEST OR OBSERVATION Hammer: 10kg falling 550mm C=1 Hammer: 10kg falling 550mm C=1 Hammer: 10kg falling 550mm C=1 Cone: 25mm diameter with 60 degree apex angle Phi=0 Cone: 25mm diameter with 60 degree apex angle Phi=0 Cone: 25mm diameter with 60 degree apex angle Phi=0 Depth Blows Inferred Rods: 16mm diameter, 22mm diameter couplings Depth Blows Inferred Rods: 16mm diameter, 22mm diameter couplings Depth Blows Inferred Rods: 16mm diameter, 22mm diameter couplings metres per 300mm Consistency metres per 300mm Consistency metres per 300mm Consistency Loose Dense Loose Med.Dense Dense Med.Dense Med.Dense Ref Dense Med.Dense Ref -1.2 Ref Depth (m) Depth (m) Depth (m) Blows per 300mm Blows per 300mm Blows per 300mm H:\11\11-358\DPL\DPL4-6

22 Tel: +27(0) Fax: +27(0) iafrica.com Client: TYRIS REALTY Ref.No Project: Proposed Development at Sprite Place, Westmead Date: Section: Operator: KN/YH L i g h t D y n a m i c P e n e t r o m e t e r P r o b e T e s t N o. DPL 7 L i g h t D y n a m i c P e n e t r o m e t e r P r o b e T e s t N o. DPL 8 L i g h t D y n a m i c P e n e t r o m e t e r P r o b e T e s t N o. DPL 9 THE INSITU STRENGTH DEPENDS ON SOIL MOISTURE CONTENT AND GRAIN STRUCTURE WHICH HAVE NOT BEEN ASSESSED AND MAY CHANGE. THE VALUES GIVEN ARE THEREFORE INDICATIVE ONLY AND SHOULD BE VERIFIED BY TEST OR OBSERVATION Hammer: 10kg falling 550mm C=1 Hammer: 10kg falling 550mm C=1 Hammer: 10kg falling 550mm C=1 Cone: 25mm diameter with 60 degree apex angle Phi=0 Cone: 25mm diameter with 60 degree apex angle Phi=0 Cone: 25mm diameter with 60 degree apex angle Phi=0 Depth Blows Inferred Rods: 16mm diameter, 22mm diameter couplings Depth Blows Inferred Rods: 16mm diameter, 22mm diameter couplings Depth Blows Inferred Rods: 16mm diameter, 22mm diameter couplings metres per 300mm Consistency metres per 300mm Consistency metres per 300mm Consistency Loose Med.Dense Med.Dense Med.Dense Med.Dense Med.Dense Med.Dense Ref Loose Ref Med.Dense Dense Dense -1.8 Ref Depth (m) Depth (m) Depth (m) Blows per 300mm Blows per 300mm Blows per 300mm H:\11\11-358\DPL\DPL7-9

23 Tel: +27(0) Fax: +27(0) iafrica.com Client: TYRIS REALTY Ref.No Project: Proposed Development at Sprite Place, Westmead Date: Section: Operator: KN/YH L i g h t D y n a m i c P e n e t r o m e t e r P r o b e T e s t N o. DPL 10 L i g h t D y n a m i c P e n e t r o m e t e r P r o b e T e s t N o. DPL 11 L i g h t D y n a m i c P e n e t r o m e t e r P r o b e T e s t N o. DPL 12 THE INSITU STRENGTH DEPENDS ON SOIL MOISTURE CONTENT AND GRAIN STRUCTURE WHICH HAVE NOT BEEN ASSESSED AND MAY CHANGE. THE VALUES GIVEN ARE THEREFORE INDICATIVE ONLY AND SHOULD BE VERIFIED BY TEST OR OBSERVATION Hammer: 10kg falling 550mm C=1 Hammer: 10kg falling 550mm C=1 Hammer: 10kg falling 550mm C=1 Cone: 25mm diameter with 60 degree apex angle Phi=0 Cone: 25mm diameter with 60 degree apex angle Phi=0 Cone: 25mm diameter with 60 degree apex angle Phi=0 Depth Blows Inferred Rods: 16mm diameter, 22mm diameter couplings Depth Blows Inferred Rods: 16mm diameter, 22mm diameter couplings Depth Blows Inferred Rods: 16mm diameter, 22mm diameter couplings metres per 300mm Consistency metres per 300mm Consistency metres per 300mm Consistency Dense Med.Dense Dense Med.Dense Dense Dense Dense Dense Ref Ref -1.2 Ref Depth (m) Depth (m) Depth (m) Blows per 300mm Blows per 300mm Blows per 300mm H:\11\11-358\DPL\DPL10-12

24 APPENDIX C Geotechnical Investigation for the Proposed Warehouse Development at Sprite Place, Westmead Path: H:\11\11-358\Reports\11-358R01.doc

25

26

27

28

29

30

31

32 FIGURE Geotechnical Investigation for the Proposed Warehouse Development at Sprite Place, Westmead Path: H:\11\11-358\Reports\11-358R01.doc

33 NORTH DPL 3 (1.2) IP DPL 2 (0.3) OFFICES DPL 4 (1.2) IP IP DPL 6 (0.9) DPL 7 (0.9) DPL 8 (0.6) DPL 1 (0.6) DPL 10 (0.9) DPL 11 (0.9) DPL 12 (0.6) DPL 5 (0.6) IP IP DPL 9 (1.8) IP IP IP WASH BAY IP WORKSHOP STORE GATE HOUSE ABLUTIONS 0m 50m 100m Graphic Scale 1 : KEY: IP DPL 1 (3.3) Approximate position of Inspection Pit showing final depth in metres below existing ground level. Approximate position of Dynamic Cone Penetrometer Test (Light) showing depth to refusal in metres below existing ground level. Site Plan showing approximate positions of : a.) Inspection Pits. b.) Dynamic Cone Penetrometer Tests (Light) Scale 1 : 1000 (On A3 Original) TYRIS REALTY Geotechnical Investigation for Proposed Development at Sprite Place, Westmead M O O RE SPEN CE JO N ES CONSULTING GEOTECHNICAL, CIVIL & ENVIRONMENTAL ENGINEERS & SCIENTISTS DATE DRAWN CHECK 10/02/2012 A.S. M.R. REFERENCE No FIGURE No. 1 REV fig1.drg

Project No.: R01

Project No.: R01 Report to Voigts Construction on a Geotechnical Investigation carried out for the Royal Albert Lodge, Albert Falls Dam, KwaZulu-Natal Project No.: 18-156R01 Date Issued: November 2018 Report to Voigts

More information

Appendix A. Producer Statement Advisory Note

Appendix A. Producer Statement Advisory Note Appendix A Producer Statement Advisory Note Ref. No. 17095 26 May 2017 PRODUCER STATEMENT CONSTRUCTION REVIEW (PS4) IMPORTANT ADVISORY NOTE The Building Consent Authority (BCA) frequently requires Producer

More information

Telephone : G. Ntaka : Fax : M. Bénet :

Telephone : G. Ntaka : Fax : M. Bénet : Our Ref: P 24058 Your Ref: Drennan Maud cc. CK 95/54198/23 Consulting Geotechnical Engineers & Engineering Geologists VAT Reg ¹ 4770223594 P.O. Box 22997 Unit 7, Gayridge Business Park ¹ 2 MARGATE 13 Wingate

More information

REPORT NO 12/115/D NOVEMBER 2012 GEOTECHNICAL INVESTIGATION FOR THE PROPOSED SOLAR PHOTOVOLTAIC FACILITY, GROOTVLEI POWER STATION

REPORT NO 12/115/D NOVEMBER 2012 GEOTECHNICAL INVESTIGATION FOR THE PROPOSED SOLAR PHOTOVOLTAIC FACILITY, GROOTVLEI POWER STATION Consulting Geotechnical Engineers & Engineering Geologists P.O.Box 3557 Cramerview 2060. Tel: (011) 465-1699. Fax: (011) 465-4586. Cell 082 556 7302 & 076 966 8445 REPORT NO 12/115/D NOVEMBER 2012 GEOTECHNICAL

More information

DRENNAN, MAUD & PARTNERS

DRENNAN, MAUD & PARTNERS DRENNAN, MAUD & PARTNERS Consulting Civil Engineers and Engineering Geologists Registered Member : S.A. Association of Consulting Engineers PARTNERS: R.D. COLLYER, Pr.Eng.,B.Sc.(Eng.),M.Sc.(Eng.),MSAICE.

More information

GEOTECHNICAL INVESTIGATION FOR REDHOUSE CHELSEA ARTERIAL AND WALKER DRIVE EXTENSION, PORT ELIZABETH, EASTERN CAPE

GEOTECHNICAL INVESTIGATION FOR REDHOUSE CHELSEA ARTERIAL AND WALKER DRIVE EXTENSION, PORT ELIZABETH, EASTERN CAPE GEOTECHNICAL INVESTIGATION FOR REDHOUSE CHELSEA ARTERIAL AND WALKER DRIVE EXTENSION, PORT ELIZABETH, EASTERN CAPE MAY 2010 Prepared for: Prepared by: BKS (PTY) LTD TERRATEST (PTY) LTD P.O. Box 272 P.O.

More information

UNDP HARARE HOSPITAL PROPOSED NATPHARM WAREHOUSE

UNDP HARARE HOSPITAL PROPOSED NATPHARM WAREHOUSE UNDP HARARE HOSPITAL PROPOSED NATPHARM WAREHOUSE January 17 2016 TO CARRY OUT IN-SITU SOIL SURVEY, LABORATORY TESTS AND GEOTECHNICAL REPORTING. GEOTECHNICAL INVESTIGATIONS REPORT 1 2 Re: GEOTECHNICAL INVESTIGATIONS

More information

DRENNAN MAUD (PTY) LTD

DRENNAN MAUD (PTY) LTD DRENNAN MAUD (PTY) LTD GEOTECHNICAL ENGINEERS AND ENGINEERING GEOLOGISTS Incorporating Drennan Maud & Partners (Est.1975) and GAP Consulting Reg. No. 2014/038872/07 Durban Head Office Info@drennanmaud.com

More information

APPENDIX 6: GEOTECHNICAL FEASIBILITY INVESTIGATION

APPENDIX 6: GEOTECHNICAL FEASIBILITY INVESTIGATION APPENDIX 6: GEOTECHNICAL FEASIBILITY INVESTIGATION ENVIRONMENTAL SCIENCE ASSOCIATES SAMANCOR CHROME, MIDDELBURG GEOTECHNICAL FEASIBILITY INVESTIGATION FOR NEW CHROME PLANT FACILITY J VAN TONDER (PrSciNat)

More information

GEOTECHNICAL PHASE 1

GEOTECHNICAL PHASE 1 GEOTECHNICAL PHASE 1 FOR PROPOSED SKUKUZA SAFARI LODGE FOR KRUGER NATIONAL PARK MPUMALANGA PROVINCE SEPTEMBER 2014 Report No: G14-0902 Issue 2 Prepared by: Conic North Consulting Engineers PO Box 11862

More information

Project: ITHACA-TOMPKINS REGIONAL AIRPORT EXPANSION Project Location: ITHACA, NY Project Number: 218-34 Key to Soil Symbols and Terms TERMS DESCRIBING CONSISTENCY OR CONDITION COARSE-GRAINED SOILS (major

More information

Photo 1 - Southerly view across 2700 parking lot toward existing building. Multi-residential building borders western side of property in upper right of view. Photo 2 - Southerly view across 2750 parking

More information

A. V T = 1 B. Ms = 1 C. Vs = 1 D. Vv = 1

A. V T = 1 B. Ms = 1 C. Vs = 1 D. Vv = 1 Geology and Soil Mechanics 55401 /1A (2002-2003) Mark the best answer on the multiple choice answer sheet. 1. Soil mechanics is the application of hydraulics, geology and mechanics to problems relating

More information

Geology and Soil Mechanics /1A ( ) Mark the best answer on the multiple choice answer sheet.

Geology and Soil Mechanics /1A ( ) Mark the best answer on the multiple choice answer sheet. Geology and Soil Mechanics 55401 /1A (2003-2004) Mark the best answer on the multiple choice answer sheet. 1. Soil mechanics is the application of hydraulics, geology and mechanics to problems relating

More information

Appendix F Laboratory test results

Appendix F Laboratory test results Appendix F Laboratory test results SOIL AND ROCK SAMPLE ANALYSIS LABORATORY TEST REPORT To: Bord Gais Copy: Orla Smyth (kkidd@bge.ie) From: Stephen Watson Laboratory Manager Causeway Geotech Ltd Tel: +44(0)2827666640

More information

5.2 APPENDIX D2 Geotechnical Report Jeffares & Green: 03524: Ilinge and Lesseyton Cemetery Development ILINGE AND LESSEYTON CEMETERY DEVELOPMENT - GEOTECHNICAL INVESTIGATION FINAL REPORT SEPTEMBER 2014

More information

REPORT ON THE ASSESSMENT OF TRENCHING INTHE ROAD RESERVE OF THE ROAD BETWEEN BEAUFORT WEST AND CARNAVON.

REPORT ON THE ASSESSMENT OF TRENCHING INTHE ROAD RESERVE OF THE ROAD BETWEEN BEAUFORT WEST AND CARNAVON. Contract Report CSIR/BE/TIE/SKA/59E2214 August 2018 REPORT ON THE ASSESSMENT OF TRENCHING INTHE ROAD RESERVE OF THE ROAD BETWEEN BEAUFORT WEST AND CARNAVON. Authors: Dave Ventura Anele Sambo Michael Roux

More information

REPORT TO TGC ENGINEERS CC. ON A GEOTECHNICAL INVESTIGATION FOR A PROPOSED NEW LANDFILL, CANDIDATE SITE 1 KRANTZ FONTEIN FARM KOKSTAD

REPORT TO TGC ENGINEERS CC. ON A GEOTECHNICAL INVESTIGATION FOR A PROPOSED NEW LANDFILL, CANDIDATE SITE 1 KRANTZ FONTEIN FARM KOKSTAD REPORT TO TGC ENGINEERS CC. ON A GEOTECHNICAL INVESTIGATION FOR A PROPOSED NEW LANDFILL, CANDIDATE SITE 1 KRANTZ FONTEIN FARM KOKSTAD 1. INTRODUCTION Drennan, Maud and Partners was requested by Mr Graham

More information

ATTACHMENT A PRELIMINARY GEOTECHNICAL SUMMARY

ATTACHMENT A PRELIMINARY GEOTECHNICAL SUMMARY ATTACHMENT A PRELIMINARY GEOTECHNICAL SUMMARY Kevin M. Martin, P.E. KMM Geotechnical Consultants, LLC 7 Marshall Road Hampstead, NH 0384 603-489-6 (p)/ 603-489-8 (f)/78-78-4084(m) kevinmartinpe@aol.com

More information

16 January 2018 Job Number: RICHARD NEWMAN C\- CLARK FORTUNE MCDONALD AND ASSOCIATES PO BOX 553 QUEENSTOWN

16 January 2018 Job Number: RICHARD NEWMAN C\- CLARK FORTUNE MCDONALD AND ASSOCIATES PO BOX 553 QUEENSTOWN 16 January 2018 Job Number: 50595 RICHARD NEWMAN C\- CLARK FORTUNE MCDONALD AND ASSOCIATES PO BOX 553 QUEENSTOWN CHANSEN@CFMA.CO.NZ STORMWATER DISPOSAL ASSESSMENT Dear Richard, RDAgritech were requested

More information

B-1 BORE LOCATION PLAN. EXHIBIT Drawn By: 115G BROOKS VETERINARY CLINIC CITY BASE LANDING AND GOLIAD ROAD SAN ANTONIO, TEXAS.

B-1 BORE LOCATION PLAN. EXHIBIT Drawn By: 115G BROOKS VETERINARY CLINIC CITY BASE LANDING AND GOLIAD ROAD SAN ANTONIO, TEXAS. N B-1 SYMBOLS: Exploratory Boring Location Project Mngr: BORE LOCATION PLAN Project No. GK EXHIBIT Drawn By: 115G1063.02 GK Scale: Checked By: 1045 Central Parkway North, Suite 103 San Antonio, Texas 78232

More information

University of Fort Hare, Alice Campus

University of Fort Hare, Alice Campus University of Fort Hare, Alice Campus Geotechnical Investigation COMPILED FOR: MBB Consulting Engineers P O Box 509 Grahamstown 6140 Telephone: +27 (0)46 622 7223 Facsimile: +27 (0)86 570 7844 COMPILED

More information

Safe bearing capacity evaluation of the bridge site along Syafrubesi-Rasuwagadhi road, Central Nepal

Safe bearing capacity evaluation of the bridge site along Syafrubesi-Rasuwagadhi road, Central Nepal Bulletin of the Department of Geology Bulletin of the Department of Geology, Tribhuvan University, Kathmandu, Nepal, Vol. 12, 2009, pp. 95 100 Safe bearing capacity evaluation of the bridge site along

More information

GEOTECHNICAL INVESTIGATION REPORT

GEOTECHNICAL INVESTIGATION REPORT GEOTECHNICAL INVESTIGATION REPORT SOIL INVESTIGATION REPORT FOR STATIC TEST FACILITY FOR PROPELLANTS AT BDL, IBRAHIMPATNAM. Graphics Designers, M/s Architecture & Engineering 859, Banjara Avenue, Consultancy

More information

APPENDIX A. Borehole Logs Explanation of Terms and Symbols

APPENDIX A. Borehole Logs Explanation of Terms and Symbols APPENDIX A Borehole Logs Explanation of Terms and Symbols Page 153 of 168 EXPLANATION OF TERMS AND SYMBOLS The terms and symbols used on the borehole logs to summarize the results of field investigation

More information

Report on Site Classification & Construction Testing

Report on Site Classification & Construction Testing Report on Site Classification & Construction Testing Northlakes Estate Stage 29, Cameron Park CGS1871 CGS1871 Prepared for Northlakes Pty Ltd C/- McCloy Group Pty Ltd December 2013 Report on Site Classification

More information

5.2 APPENDIX D2 Geotechnical Report Jeffares & Green: 03524: Ilinge and Lesseyton Cemetery Development ILINGE AND LESSEYTON CEMETERY DEVELOPMENT - GEOTECHNICAL INVESTIGATION FINAL REPORT SEPTEMBER 2014

More information

DRENNAN MAUD (PTY) LTD

DRENNAN MAUD (PTY) LTD DRENNAN MAUD (PTY) LTD GEOTECHNICAL ENGINEERS AND ENGINEERING GEOLOGISTS Incorporating Drennan Maud & Partners (Est.1975) and GAP Consulting Reg. No. 2014/038872/07 Durban Head Office Info@drennanmaud.com

More information

6.2 Geotechnical Investigation and Construction Material Survey

6.2 Geotechnical Investigation and Construction Material Survey 6.2 Geotechnical Investigation and Construction Material Survey Geological surveys and investigations were conducted to obtain information on the subsurface geological condition required for the preliminary

More information

GEOTECHNICAL REPORT. Matanuska-Susitna Borough. Parks Highway Connections Museum Drive. Matanuska-Susitna Borough, Alaska.

GEOTECHNICAL REPORT. Matanuska-Susitna Borough. Parks Highway Connections Museum Drive. Matanuska-Susitna Borough, Alaska. Matanuska-Susitna Borough GEOTECHNICAL REPORT Parks Highway Connections Museum Drive Matanuska-Susitna Borough, Alaska March 2, 20 Prepared By: John Thornley, PE Geotechnical Engineer 333 Arctic Blvd.,

More information

February 22, 2016 AG File No

February 22, 2016 AG File No Ainley Graham & Associates Limited 1-50 Grant Timmins Drive, Kingston, Ontario, K7M 8N2 Tel: (343) 266-0002 Fax: (343) 266-0028 E-mail Kingston@ainleygroup.com February 22, 2016 AG File No. 15062-1 Ministry

More information

Reference No S072 APRIL 2012

Reference No S072 APRIL 2012 A REPORT TO SOLMAR DEVELOPMENT CORP. A PRELIMINARY SOIL INVESTIGATION FOR PROPOSED SUBDIVISION DEVELOPMENT NORTHEAST OF SIDEROAD 5 AND 0 LINE TOWN OF ERIN Reference No. 202-S072 APRIL 202 DISTRIBUTION

More information

Geotechnical Engineering Study, Conifer Senior High School Football Field Improvements, Conifer, Colorado

Geotechnical Engineering Study, Conifer Senior High School Football Field Improvements, Conifer, Colorado 2390 South Lipan Street Denver, CO 80223 phone: (303) 742-9700 fax: (303) 742-9666 email: kadenver@kumarusa.com www.kumarusa.com Office Locations: Denver (HQ), Colorado Springs, Fort Collins, and Frisco,

More information

Unbound Pavement Applications of Excess Foundry System Sands: Subbase/Base Material

Unbound Pavement Applications of Excess Foundry System Sands: Subbase/Base Material Unbound Pavement Applications of Excess Foundry System Sands: Subbase/Base Material Tuncer B. Edil University of Wisconsin-Madison Recycled Materials Resource Center RMRC Participant Job Description Which

More information

Civil Engineering, Surveying and Environmental Consulting WASP0059.ltr.JLS.Mich Ave Bridge Geotech.docx

Civil Engineering, Surveying and Environmental Consulting WASP0059.ltr.JLS.Mich Ave Bridge Geotech.docx 2365 Haggerty Road South * Canton, Michigan 48188 P: 734-397-3100 * F: 734-397-3131 * www.manniksmithgroup.com August 29, 2012 Mr. Richard Kent Washtenaw County Parks and Recreation Commission 2330 Platt

More information

Lake Rotoiti Wastewater Scheme - Stage 1 Investigations. Rotorua Lakes Council

Lake Rotoiti Wastewater Scheme - Stage 1 Investigations. Rotorua Lakes Council Lake Rotoiti Wastewater Scheme - Stage 1 Investigations Rotorua Lakes Council i Contents 1 Introduction...1 2 Site Description...1 3 Geological Setting...1 4 Geotechnical Investigation...1 4.1 Borehole

More information

Northern Colorado Geotech

Northern Colorado Geotech PRELIMINARY GEOTECHNICAL ENGINEERING REPORT PROPOSED CECIL FARMS DEVELOPMENT WELD COUNTY ROAD 7, BETWEEN ROADS 7 AND 7 SEVERANCE, COLORADO NORTHERN COLORADO GEOTECH PROJECT NO. 0-6 APRIL 0, 06 Prepared

More information

SOIL CLASSIFICATION CHART COARSE-GRAINED SOILS MORE THAN 50% RETAINED ON NO.200 SIEVE FINE-GRAINED SOILS 50% OR MORE PASSES THE NO.200 SIEVE PRIMARY DIVISIONS GRAVELS MORE THAN 50% OF COARSE FRACTION RETAINED

More information

APPENDIX A GEOTECHNICAL REPORT

APPENDIX A GEOTECHNICAL REPORT The City of Winnipeg Bid Opportunity No. 529-2017 Template Version: C420170317 - RW APPENDIX A GEOTECHNICAL REPORT Quality Engineering Valued Relationships KGS Group 2017 Industrial Street Rehabilitation

More information

APPENDIX E SOILS TEST REPORTS

APPENDIX E SOILS TEST REPORTS Otsego County, NY Site Work Specifications APPENDIX E SOILS TEST REPORTS Blue Wing Services, Inc. July 1, 2010 Blue Wing Services May 20, 2010 Page 2 the site, was not made available to Empire at this

More information

GEOLOGICAL PROCESSES AND MATERIALS SGM210

GEOLOGICAL PROCESSES AND MATERIALS SGM210 University of Pretoria GEOLOGICAL PROCESSES AND MATERIALS SGM210 23 April 2014 1 SOIL PROFILING According to Jennings, Brink & Williams (1973) Very important part of a geotechnical site investigation.

More information

Geotechnical Data Report

Geotechnical Data Report Geotechnical Data Report Downtown Greenville Future Conveyance Study December 1, 2015 Terracon Project No. 86155032 Prepared for: Prepared by: Terracon Consultants, Inc. December 1, 2015 561 Mauldin Road

More information

Preliminary Geotechnical Investigation Cadiz / Trigg County I-24 Business Park. Cadiz, Kentucky

Preliminary Geotechnical Investigation Cadiz / Trigg County I-24 Business Park. Cadiz, Kentucky Environmental & Geoscience, LLC 834 Madisonville Road Hopkinsville, KY 440 70.44.000 FAX 70.44.8300 www.wedrill.com A member of Trinity Energy & Infrastructure Group, LLC Preliminary Geotechnical Investigation

More information

Clay Robinson, PhD, CPSS, PG copyright 2009

Clay Robinson, PhD, CPSS, PG   copyright 2009 Engineering: What's soil got to do with it? Clay Robinson, PhD, CPSS, PG crobinson@wtamu.edu, http://www.wtamu.edu/~crobinson, copyright 2009 Merriam-Webster Online Dictionary soil, noun 1 : firm land

More information

B-1 SURFACE ELEVATION

B-1 SURFACE ELEVATION 5A 5B LOGGED BY El. S. Bhangoo DRILLING CONTRACTOR Pitcher Drilling DRILLING METHOD Rotary Wash BEGIN DATE 12-14-12 SAMPLER TYPE(S) AND SIZE(S) (ID) SPT, MC BOREHOLE BACKFILL AND COMPLETION COMPLETION

More information

SUPPLEMENTARY INVESTIGATION AND LABORATORY TESTING Aggregate Resource Evaluation Proposed Bernand Quarry San Diego County, California

SUPPLEMENTARY INVESTIGATION AND LABORATORY TESTING Aggregate Resource Evaluation Proposed Bernand Quarry San Diego County, California October 3, 2 Mr. Mark San Agustin Project No. 28-- Home Land Investments Document No. -92 2239 Curlew Street San Diego, CA 92 SUBJECT: SUPPLEMENTARY INVESTIGATION AND LABORATORY TESTING Aggregate Resource

More information

SOIL INVESTIGATION REPORT. PROPOSED HOUSING DEVELOPMENT PROJECT Coral Spring, Trelawny, Jamaica.

SOIL INVESTIGATION REPORT. PROPOSED HOUSING DEVELOPMENT PROJECT Coral Spring, Trelawny, Jamaica. SOIL INVESTIGATION REPORT PROPOSED HOUSING DEVELOPMENT PROJECT Coral Spring, Trelawny, Jamaica. Prepared for: FCS Consultants 7a Barbados Avenue Kingston 5, Jamaica Prepared by: NHL Engineering Limited

More information

APPENDIX C. Borehole Data

APPENDIX C. Borehole Data APPENDIX C Borehole Data MAJOR DIVISIONS SOIL CLASSIFICATION CHART SYMBOLS GRAPH LETTER TYPICAL DESCRIPTIONS ADDITIONAL MATERIAL

More information

Report of Preliminary Geotechnical Exploration. CSO-012 Sewer Separation Cincinnati, Hamilton County, Ohio. February, 2011

Report of Preliminary Geotechnical Exploration. CSO-012 Sewer Separation Cincinnati, Hamilton County, Ohio. February, 2011 11242843_GeoTech_Preliminary - Feburary 2011_1/40 Report of Preliminary Geotechnical Exploration CSO-012 Sewer Separation Cincinnati, Hamilton County, Ohio February, 2011 11242843_GeoTech_Preliminary -

More information

Pierce County Department of Planning and Land Services Development Engineering Section

Pierce County Department of Planning and Land Services Development Engineering Section Page 1 of 7 Pierce County Department of Planning and Land Services Development Engineering Section PROJECT NAME: DATE: APPLICATION NO.: PCDE NO.: LANDSLIDE HAZARD AREA (LHA) GEOLOGICAL ASSESSMENT REPORT

More information

Boreholes. Implementation. Boring. Boreholes may be excavated by one of these methods: 1. Auger Boring 2. Wash Boring 3.

Boreholes. Implementation. Boring. Boreholes may be excavated by one of these methods: 1. Auger Boring 2. Wash Boring 3. Implementation Boreholes 1. Auger Boring 2. Wash Boring 3. Rotary Drilling Boring Boreholes may be excavated by one of these methods: 4. Percussion Drilling The right choice of method depends on: Ground

More information

R-1 Conveyor Relocation Project Legend 0 500 1000 1500 ft. This map is a user generated static output from an Internet mapping site and is for general reference only. Data layers that appear on this map

More information

Project No: 68R3056 Client: City of Frederick Project: RFQ 14-H Future North Side Water Tank City/State: 7516 Hayward Road, Frederick, MD

Project No: 68R3056 Client: City of Frederick Project: RFQ 14-H Future North Side Water Tank City/State: 7516 Hayward Road, Frederick, MD Boring: SB-1 (1 of 1) Moist, brown to orange brown CLAY and SILT, trace sand with fine weathered rock fragments. POSSIBLE FILL. Dry, orange brown sandy SILT trace clay (SM-ML). RESIDUAL SOIL : Not Surveyed

More information

Ardaman & Associates, Inc. Geotechnical, Environmental and Materials Consultants

Ardaman & Associates, Inc. Geotechnical, Environmental and Materials Consultants SUBSURFACE SOIL EXPLORATION DRAINAGE IMPROVEMENTS TO THE HENDRY COUNTY, FLORIDA Ardaman & Associates, Inc. Geotechnical, Environmental and Materials Consultants OFFICES Orlando, 88 S. Orange Avenue, Orlando,

More information

GEOTECHNICAL INVESTIGATION OF RAILWAYS

GEOTECHNICAL INVESTIGATION OF RAILWAYS GEOTECHNICAL INVESTIGATION OF RAILWAYS Prof. Hannes Gräbe University of Pretoria Transnet Chair in Railway Engineering May 2011 Contents Cost considerations Objectives Phased approach to site investigation

More information

LEGEND BUSINESS ZONE NORTH OF AGRESEARCH BOREHOLE CPT SEISMIC CPT AUGER SCALE. Powells Road TEST PIT AGRESEARCH INNOVATION PARK. Hamilton Ring Road

LEGEND BUSINESS ZONE NORTH OF AGRESEARCH BOREHOLE CPT SEISMIC CPT AUGER SCALE. Powells Road TEST PIT AGRESEARCH INNOVATION PARK. Hamilton Ring Road LEGEND ra R aku Ru BUSINESS ZONE NORTH OF Powells Road oad AGRESEARCH BOREHOLE CPT SEISMIC CPT AUGER SCALE 3 mm TEST PIT AS121 SCPT12 TP18 BH13 TP15 2 AS125 AS126 TP14 BH12 AGRESEARCH CPT13 TP17 INNOVATION

More information

Limited Geotechnical Engineering Evaluation Classroom Additions Albany County Campus Laramie, Wyoming

Limited Geotechnical Engineering Evaluation Classroom Additions Albany County Campus Laramie, Wyoming Limited Geotechnical Engineering Evaluation Classroom Additions Albany County Campus 2300 Missile Drive, Cheyenne, Wyoming 82001 Phone 307-635-0222 www.stratageotech.com Limited Geotechnical Engineering

More information

Comparative Study of Geotechnical Properties of Abia State Lateritic Deposits

Comparative Study of Geotechnical Properties of Abia State Lateritic Deposits IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) e-issn: 2278-1684,p-ISSN: 2320-334X, Volume 12, Issue 1 Ver. II (Jan- Feb. 2015), PP 77-84 www.iosrjournals.org Comparative Study of Geotechnical

More information

Variability in Some Geotechnical Properties of Three Lateritic Sub-Base Soils Along Ibadan Oyo Road

Variability in Some Geotechnical Properties of Three Lateritic Sub-Base Soils Along Ibadan Oyo Road IOSR Journal of Applied Geology and Geophysics (IOSR-JAGG) e-issn: 2321 0990, p-issn: 2321 0982.Volume 2, Issue 5 (Jul-Aug. 2014), PP 76-81 Variability in Some Geotechnical Properties of Three Lateritic

More information

Manor Farm, Otley Road, Adel - preliminary findings

Manor Farm, Otley Road, Adel - preliminary findings 005/87/ 6 th September 07 Mr G Titchmarsh Titchmarsh & Bagley. Prospect House Sovereign Street Leeds LS BJ Registered in England 07068066 Parkhill Wetherby West Yorkshire LS 5DZ T 097 55 0 www.lithos.co.uk

More information

Solution:Example 1. Example 2. Solution: Example 2. clay. Textural Soil Classification System (USDA) CE353 Soil Mechanics Dr.

Solution:Example 1. Example 2. Solution: Example 2. clay. Textural Soil Classification System (USDA) CE353 Soil Mechanics Dr. CE353 Soil Mechanics CE353 Lecture 5 Geotechnical Engineering Laboratory SOIL CLASSIFICATION Lecture 5 SOIL CLASSIFICATION Dr. Talat A Bader Dr. Talat Bader 2 Requirements of a soil Systems Why do we need

More information

Superficial Geology Map - Slice A. Order Details: Order Number: Customer Reference: National Grid Reference: Slice: Site Area (Ha): Search Buffer (m):

Superficial Geology Map - Slice A. Order Details: Order Number: Customer Reference: National Grid Reference: Slice: Site Area (Ha): Search Buffer (m): Superficial Geology Superficial Deposits are the youngest geological deposits formed during the most recent period of geological time, the Quaternary, which extends back about 1.8 million years from the

More information

GAUTENG INDUSTRIAL DEVELOPMENT ZONE PRELIMINARY REPORT

GAUTENG INDUSTRIAL DEVELOPMENT ZONE PRELIMINARY REPORT 1 GAUTENG INDUSTRIAL DEVELOPMENT ZONE GEOTECHNICAL INVESTIGATIONS REPORT FOR: JEWELLERY MANUFACTURING PRECINCT PRELIMINARY REPORT Prepared By: April 2015 OFFICE Plot 70 Tienie Street Andeon Zandfontein

More information

Geotechnical Engineering Report

Geotechnical Engineering Report Geotechnical Engineering Report Richland Creek Trunk Sewer Greenville, South Carolina March 31, 2014 Terracon Project No. 86145008 Prepared for: Renewable Water Resources Greenville, South Carolina Prepared

More information

SECTION AGGREGATE OR GRANULAR SUBBASE

SECTION AGGREGATE OR GRANULAR SUBBASE SECTION 02230 AGGREGATE OR GRANULAR SUBBASE PART 1 GENERAL 1.01 SECTION INCLUDES A. Aggregate or granular subbase as shown on the drawings. 1.02 RELATED SECTIONS A. Section 01400 Quality Requirements.

More information

General. DATE December 10, 2013 PROJECT No TO Mary Jarvis Urbandale/Riverside South Development Corporation

General. DATE December 10, 2013 PROJECT No TO Mary Jarvis Urbandale/Riverside South Development Corporation DATE December 10, 201 PROJECT No. 10-1121-0260- TO Mary Jarvis Urbandale/Riverside South Development Corporation CC Justin Robitaille, Urbandale Jonathan Párraga, J.L. Richards & Associates Limited FROM

More information

Geotechnical Investigation Report

Geotechnical Investigation Report Geotechnical Investigation Report Proposed Salt Storage Shed Majestic Hills Drive Hamilton Township, Ontario Hamilton Township 7 Pido Road Peterborough Ontario K9J 6X7 Canada 568 0 Report No June 08 Table

More information

SOIL AND AGGREGATE FUNDAMENTALS STUDENT GUIDE AMRC April, 2006 AREA MANAGER ROADS CERTIFICATION PROGRAM FOR EDUCATIONAL PURPOSES ONLY

SOIL AND AGGREGATE FUNDAMENTALS STUDENT GUIDE AMRC April, 2006 AREA MANAGER ROADS CERTIFICATION PROGRAM FOR EDUCATIONAL PURPOSES ONLY AREA MANAGER ROADS CERTIFICATION PROGRAM AMRC 2011 SOIL AND AGGREGATE FUNDAMENTALS STUDENT GUIDE FOR EDUCATIONAL PURPOSES ONLY April, 2006 WPC #28013 07/09 2009 by British Columbia Institute of Technology

More information

SITE INVESTIGATION 1

SITE INVESTIGATION 1 SITE INVESTIGATION 1 Definition The process of determining the layers of natural soil deposits that will underlie a proposed structure and their physical properties is generally referred to as site investigation.

More information

A Study on Suitability of Crusher Dust Stabilized Red Earth and Gravel as Subgrade and Sub Base Material

A Study on Suitability of Crusher Dust Stabilized Red Earth and Gravel as Subgrade and Sub Base Material SSRG International Journal of Civil Engineering (SSRG-IJCE) volume 5 Issue 4 April 218 A Study on Suitability of Crusher Dust Stabilized Red Earth and Gravel as Subgrade and Sub Base Material Prof. P.V.V.Satyanarayana

More information

patersongroup Mineral Aggregate Assessment 3119 Carp Road Ottawa, Ontario Prepared For Mr. Greg LeBlanc March 7, 2014 Report: PH2223-REP.

patersongroup Mineral Aggregate Assessment 3119 Carp Road Ottawa, Ontario Prepared For Mr. Greg LeBlanc March 7, 2014 Report: PH2223-REP. Geotechnical Engineering Environmental Engineering group Hydrogeology Geological Engineering Archaeological Studies Materials Testing 3119 Carp Road Prepared For Mr. Greg LeBlanc March 7, 2014 Paterson

More information

GEOTECHNICAL INVESTIGATION REPORT INFRASTRUCTURE PVT LTD

GEOTECHNICAL INVESTIGATION REPORT INFRASTRUCTURE PVT LTD GEOTECHNICAL INVESTIGATION REPORT Client : TAEIN CONSTRUCTION & INFRASTRUCTURE PVT LTD Office address : Flat No.104, A -Wing,1st floor,gloria Park, Paranjape Scheme, Bavdhan Khurd, Chandni Chowk, Pune

More information

Geotechnical Engineering Report

Geotechnical Engineering Report Geotechnical Engineering Report Turner Turnpike Widening Polecat Creek Bridge (Bridge A) June 1, 2016 Terracon Project No. 04155197 Prepared for: Garver, LLC Prepared by: Terracon Consultants, Inc. TABLE

More information

Milford Centre Ltd. Private Plan Change GEOTECHNICAL ASSESSMENT

Milford Centre Ltd. Private Plan Change GEOTECHNICAL ASSESSMENT Milford Centre Ltd. Private Plan Change GEOTECHNICAL ASSESSMENT Final 15 April 2008 Milford Centre Ltd. Private Plan Change GEOTECHNICAL ASSESSMENT Final 15 April 2008 Sinclair Knight Merz 25 Teed Street

More information

Assessment of the Geotechnical Properties of Lateritic Soils in Minna, North Central Nigeria for Road design. and Construction

Assessment of the Geotechnical Properties of Lateritic Soils in Minna, North Central Nigeria for Road design. and Construction American Journal of Mining and Metallurgy, 2015, Vol. 3, No. 1, 15-20 Available online at http://pubs.sciepub.com/ajmm/3/1/3 Science and Education Publishing DOI:10.12691/ajmm-3-1-3 Assessment of the Geotechnical

More information

ADDENDUM 1 FISHER SLOUGH RESTORATION PROJECT SKAGIT COUNTY, WASHINGTON

ADDENDUM 1 FISHER SLOUGH RESTORATION PROJECT SKAGIT COUNTY, WASHINGTON F I N A L A D D E N D U M 1 R E P O R T ADDENDUM 1 FISHER SLOUGH RESTORATION PROJECT SKAGIT COUNTY, WASHINGTON REPORT OF GEOTECHNICAL INVESTIGATION URS JOB NO. 3376186 Prepared for Tetra Tech Inc. 142

More information

File: Highway 1 Admirals/McKenzie Interchange, Saanich, BC Pavement Drilling / Coring Geotechnical Investigation

File: Highway 1 Admirals/McKenzie Interchange, Saanich, BC Pavement Drilling / Coring Geotechnical Investigation TECHNICAL MEMO To: Mr. Salem Bahamdun, P.Eng. Date: February 2, 2017 c: Memo No.: From: Ms. Susanne Ouellet, E.I.T. Mr. Andrew Walker, P.Eng. File: 704TRN.PAVE0303807 ISSUED FOR USE Subject: Highway 1

More information

Hydro One (Sept 2014) Hydro One (Sept 2014) Hydro One (Sept 2014)

Hydro One (Sept 2014) Hydro One (Sept 2014) Hydro One (Sept 2014) TABLE 1 WELL CONSTRUCTION DETAILS MOE WWR No Well ID Location Installation Date Status Easting Coordinates Northing Source Elevation Screened Interval Screened Material Borehole Well Stick-up Ground Top

More information

Appendix G: Geology and Geotechnical

Appendix G: Geology and Geotechnical Appendix G: Geology and Geotechnical Geology GEOTECHNICAL INVESTIGATION FOR THE PROPOSED CONTINUOUS ASH DISPOSAL FACILITY FOR THE MATIMBA POWER STATION LOCATED IN LEPHALALE, LIMPOPO PROVINCE APRIL 2013

More information

Appendix G GEOLOGICAL INVESTIGATION

Appendix G GEOLOGICAL INVESTIGATION Appendix G GEOLOGICAL INVESTIGATION JOB NUMBER: 3268.001 DATE: 10-14-13 BY: CC SITE 0 2000 1"=2000' VICINITY MAP CARGILL PARCEL HICKORY STREET AND ENTERPRISE DRIVE NEWARK, CALIFORNIA FOR

More information

Baseline Survey for a Bank Stability Assessment for the Mpofana River

Baseline Survey for a Bank Stability Assessment for the Mpofana River 4a Old Main Road, Judges Walk, Kloof, Kwazulu-Natal, South Africa, 360 PO Box 89, Gillitts, 3603, South Africa Tel: +27 (0) 3 764 730 Fax: +27 (0) 3 764 740 Web: www.gcs-sa.biz Baseline Survey for a Bank

More information

Geotechnical Engineering Report

Geotechnical Engineering Report Geotechnical Engineering Report Turner Turnpike Widening Bridge B Bridge Crossing: South 257 th West Avenue Creek County, Oklahoma June 1, 2016 Terracon Project No. 04155197 Prepared for: Garver, LLC Tulsa,

More information

Yumbah Nyamat Works Approval Application October Appendix J. Geotechnical Site Investigation

Yumbah Nyamat Works Approval Application October Appendix J. Geotechnical Site Investigation Yumbah Nyamat Works Approval Application October 2018 Appendix J Geotechnical Site Investigation GEOTECHNICAL SITE INVESTIGATION PROJECT NO: 23269-1 Client: Proposed: Location: P DESIGN GROUP NEW AQUACULTURE

More information

UNIT DESCRIPTIONS: Artificial Fill, Undocumented (Afu): Locally derived sandy silt and silty sand, locally with clay and varying amounts of gravel and man-made debris. Abundant concrete rubble, in places

More information

Ardaman & Associates, Inc. Geotechnical, Environmental and Materials Consultants

Ardaman & Associates, Inc. Geotechnical, Environmental and Materials Consultants SUBSURFACE SOIL EXPLORATION ANALYSIS AND RECOMMENDATIONS LELY AREA STORMWATER IMPROVEMENT PROJECT (LASIP) COUNTY BARN ROAD AND WING SOUTH CHANNELS NAPLES, COLLIER CO., FLORIDA Ardaman & Associates, Inc.

More information

Geotechnical Investigation

Geotechnical Investigation Geotechnical Investigation Slope Stability Analysis for the Existing Slope Southwest of the Proposed Condo Developments 50 Ann Street, Bolton, Ontario Prepared For: Brookfield Homes (Ontario) Limited GeoPro

More information

14 Geotechnical Hazards

14 Geotechnical Hazards Volume 2: Assessment of Environmental Effects 296 14 Geotechnical Hazards Overview This Chapter provides an assessment of the underlying geotechnical conditions to identify: any potential liquefaction

More information

APPENDIX C HYDROGEOLOGIC INVESTIGATION

APPENDIX C HYDROGEOLOGIC INVESTIGATION Figure B-5.7 Figure B-5.8 Preliminary Geotechnical and Environmental Report Appendix C Hydrogeologic Investigation APPENDIX C HYDROGEOLOGIC INVESTIGATION December 21, 2011 WESTSIDE SUBWAY EXTENSION PROJECT

More information

REPORT. Earthquake Commission. Christchurch Earthquake Recovery Geotechnical Factual Report Bryndwr Appendix C: Borehole Logs

REPORT. Earthquake Commission. Christchurch Earthquake Recovery Geotechnical Factual Report Bryndwr Appendix C: Borehole Logs REPORT Earthquake Commission Christchurch Earthquake Recovery Geotechnical Factual Report Bryndwr Appendix C: Borehole Logs REPORT Earthquake Commission Christchurch Earthquake Recovery Geotechnical Factual

More information

PRELIMINARY GEOTECHNICAL ENGINEERING REPORT

PRELIMINARY GEOTECHNICAL ENGINEERING REPORT PRELIMINARY GEOTECHNICAL ENGINEERING REPORT TOWN OF ASHLAND TOWN HALL 101 THOMPSON STREET ASHLAND, VIRGINIA JOB NUMBER: 39016 PREPARED FOR: PMA PLANNERS & ARCHITECTS 10325 WARWICK BOULEVARD NEWPORT NEWS,

More information

Reference: R01. Dated: 18 July 2013 LEVEL 1 BEE SUPPLIER

Reference: R01. Dated: 18 July 2013 LEVEL 1 BEE SUPPLIER Geotechnical Engineering Services Engineering Geology Environmental and Groundwater Pile Integrity Testing Civil Engineering Laboratory Earthworks/Materials Supervision & Control Geotechnical Monitoring

More information

Evaluation/Monitoring Report No. 259

Evaluation/Monitoring Report No. 259 SITE 100M EAST OF 16 LEARMORE ROAD CASTLEGORE CASTLEDERG COUNTY TYRONE LICENCE NO.: AE/13/36E NAOMI CARVER 1 Site Specific Information Site Name: 100m east of 16 Learmore Road, Castlederg, Co. Tyrone Townland:

More information

PRELIMINARY GEOTECHNICAL REPORT. State College Redevelopment State College Borough, Centre County, Pennsylvania. CMT Laboratories File No.

PRELIMINARY GEOTECHNICAL REPORT. State College Redevelopment State College Borough, Centre County, Pennsylvania. CMT Laboratories File No. PRELIMINARY GEOTECHNICAL REPORT State College Redevelopment State College Borough, Centre County, Pennsylvania CMT Laboratories File No. 1638700 Prepared for: National Development Council One Battery Park

More information

Eastgate Parking Lot Geotechnical Investigation

Eastgate Parking Lot Geotechnical Investigation Eastgate Parking Lot Geotechnical Investigation Cambium Reference No.: 336- March 4, 24 Prepared for: City of Peterborough Cambium Inc. P.O. Box 325 52 Hunter Street East, Peterborough Ontario, K9H G5

More information

KDOT Geotechnical Manual Edition. Table of Contents

KDOT Geotechnical Manual Edition. Table of Contents KDOT Geotechnical Manual 2007 Edition The KDOT Geotechnical Manual is available two volumes. Both volumes are very large electronic (pdf) files which may take several minutes to download. The table of

More information

PRELIMINARY GEOTECHNICAL ENGINEERING REPORT. Proposed Re-Development 44 Old Worcester Road Charlton, Massachusetts. Prepared For:

PRELIMINARY GEOTECHNICAL ENGINEERING REPORT. Proposed Re-Development 44 Old Worcester Road Charlton, Massachusetts. Prepared For: PRELIMINARY GEOTECHNICAL ENGINEERING REPORT Proposed Re-Development 44 Old Worcester Road Charlton, Massachusetts Prepared For: Meridian Associates, Inc. 500 Cummings Center, Suite 5950 Beverly, Massachusetts

More information

REPORT ON SLOPE STABILITY INVESTIGATION DON MILLS ROAD AND EGLINTON AVENUE EAST TORONTO, ONTARIO. Prepared for:

REPORT ON SLOPE STABILITY INVESTIGATION DON MILLS ROAD AND EGLINTON AVENUE EAST TORONTO, ONTARIO. Prepared for: REPORT ON SLOPE STABILITY INVESTIGATION DON MILLS ROAD AND EGLINTON AVENUE EAST TORONTO, ONTARIO Prepared for: TORONTO AND REGION CONSERVATION AUTHORITY Prepared By: SIRATI & PARTNERS CONSULTANTS LIMITED

More information

M E M O R A N D U M. Mr. Jonathan K. Thrasher, P.E., Mr. Ian Kinnear, P.E. (FL) PSI

M E M O R A N D U M. Mr. Jonathan K. Thrasher, P.E., Mr. Ian Kinnear, P.E. (FL) PSI M E M O R A N D U M TO: FROM: Mr. Mark Schilling Gulf Interstate Engineering Mr. Jonathan K. Thrasher, P.E., Mr. Ian Kinnear, P.E. (FL) PSI DATE: November 11, 2014 RE: Summary of Findings Geotechnical

More information

Depth (ft) USCS Soil Description TOPSOIL & FOREST DUFF

Depth (ft) USCS Soil Description TOPSOIL & FOREST DUFF Test Pit No. TP-6 Location: Latitude 47.543003, Longitude -121.980441 Approximate Ground Surface Elevation: 1,132 feet Depth (ft) USCS Soil Description 0 1.5 1.5 5.0 SM 5.0 8.0 SM Loose to medium dense,

More information

Geotechnical Foundation Investigation Highway 1 & Highway 3 Variable Speed Limit Signs

Geotechnical Foundation Investigation Highway 1 & Highway 3 Variable Speed Limit Signs Geotechnical Foundation Investigation Highway & Highway Variable Speed Limit Signs Subsurface Site Investigation Type of Document Geotechnical Information Report, Final Prepared For: Ministry of Transportation

More information