Vortex Flow Measuring System PROline prowirl 72

Size: px
Start display at page:

Download "Vortex Flow Measuring System PROline prowirl 72"

Transcription

1 Technical Information TI 062D/06/en No Vortex Flow Measuring System PROline prowirl 72 Reliable Flow Measurement of Gas, Steam and Liquids pplication For measuring the volume flow of steam, gases and liquids. For utility and process applications in the chemical, petrochemical, power and district heating industries and in many other branches. Your benefits Proven capacitive sensor (installed base > 100,000) Immune to: Vibrations (over 1 g in all axes) Temperature shocks (> 150 K/s) Dirty media Water hammer Process temp. range C Universal: Compact or remote version Dualsens version, with two sensors and electronics (for redundancy) lloy C-22 version Connection to all common systems: HRT PROFIUS-P FOUNDTION Fieldbus Galvanically isolated pulse output available (for alarm, limit value etc.). Permanent self-monitoring and diagnosis of electronics and sensor. Correction of diameter mismatch. No maintenance, no moving parts, no zero-point drift.

2 Function and system design Measuring principle Vortex shedding flowmeters work on the principle of the Karman vortex street. When a fluid flows past a bluff body, vortices are alternately formed and shed on both sides with opposite senses of rotation. These vortices each generate a local low pressure. The pressure fluctuations are recorded by the sensor and converted to electrical pulses. The vortices develop very regularly within the application limits of the device. Therefore, the frequency of vortex shedding is directly proportional to the volume flow. v F06-7xxxxxxx-15-xx-06-xx-000 The K-factor is used as the proportional constant: K-Factor = pulses unit volume [dm³] F06-7xxxxxxx-19-xx-06-en-000 Within the application limits of the device, the K-factor only depends on the geometry of the device. It is independent of the fluid velocity and its properties viscosity and density. In this way, the K-factor is also independent of the type of fluid to be measured, regardless of whether this is steam, a gas or a liquid. The primary measuring signal is already digital (frequency signal) and a linear function of the flow. fter manufacturing the meter, the K-factor is determined once-off in the factory by means of calibration and is not subjected to any long term drift or zero point shift. The device does not contain any moving parts and requires no maintenance. The capacitive sensor The sensor of a vortex flowmeter has a major influence on the performance, robustness and reliability of the whole measuring system. Prowirl 72 uses ndress + Hauser's proven and patented capacitive measuring technology, with to date more than 100,000 Vortex measuring points installed world wide. Due to its internal mechanical balance, the DSC sensor (Differential Switched Capacitance), reads only the pressure pulses caused by the vortices and stays immune to any influence from mechanical pipe line vibrations. The DSC sensor measures low flow rates at low fluid density even when pipe line vibrations are present. Therefore, Prowirl 72 keeps its wide turndown ratio even under rough operating conditions. Vibrations of at least 1g at frequencies up to 500 Hz in all axes do not affect the flow measurement. Thanks to its mechanical design, the capacitive sensor is also especially resistant to temperature shocks and water hammer in steam lines. Z-xis Sensor Seal Y-xis X-xis F06-7xxxxxxx en ndress + Hauser

3 Measuring system The measuring system consist of a sensor and a transmitter. Two versions are available: Compact version: sensor and transmitter form a mechanical unit. Remote version: sensor is mounted separate from the transmitter. Sensor Prowirl F (DN ) Flanged version (also available as version with two sensors and electronics for redundancy, DN ) Prowirl W (DN ) Wafer version Transmitter Prowirl 72 Input Measured variable Measuring range Volumetric flow (volume flow), is proportional to the frequency of vortex shedding after the bluff body. The output variables are volume flow or, if the process conditions are non-varying, calculated mass flow or corrected volume flow. The measuring range depends on the fluid and the nominal diameter. Start of measuring range: Depends on the density and the Reynolds number (Re min = 4000 Re linear = 20000) DN v min. = 6 [kg/m³] [m/s] DN v min. = 7 [kg/m³] [m/s] F06-72xxxxxx-19-xx-06-xx-002.eps Full scale value: Gas/steam: v max = 75 m/s (DN 15: v max = 46 m/s) Liquids: v max = 9 m/s Note! y using the selection and sizing software "pplicator", you can determine the exact values for the fluid you use. You can obtain pplicator from your ndress+hauser sales centre or on the Internet at Measuring range for gases [m³/h or Nm³/h] In the case of gases, the start of the measuring range depends on the density. With ideal gases, the density [ρ] or corrected density [ρ N ] can be calculated using the following formulae: [kg/m³] = N [kg/nm³] P [bar abs] [K] T [K] [bar abs] N [kg/nm³] = [kg/m³] T [K] [bar abs] P [bar abs] [K] F06-7xxxxxxx-19-xx-xx-en-002 The following formulae can be used to calculate the volume [Q] or corrected volume [Q N ] in the case of ideal gases: Q[m³/h] = Q [Nm³/h] T [K] [bar abs] N P [bar abs] [K] [Nm³/h] = Q N Q [m³/h] P [bar abs] [K] T [K] [bar abs] F06-7xxxxxxx-19-xx-xx-en-003 T = Operating temperature P = Operating pressure ndress + Hauser 3

4 Output Output signal Current output: m with HRT, Full scale value and time constant ( s) can be set Temperature coefficient: typically 0.005% o.r. / C (o.r. = of reading) Pulse/status output: Open collector, passive, Galvanically isolated, Non-x, x d: U max = 36 V, with 15 m current limit, R i = 500 Ω x i: U max = 30 V, with 15 m current limit, R i = 500 Ω Can be configured as: Pulse output: Pulse value and polarity can be selected ( ms), Pulse frequency max. 100 Hz Status output: Can be configured for error messages or flow limit values Vortex frequency: Direct output of unscaled vortex pulses Hz (pulse ratio 1:1). PFM signal (pulse-frequency modulation): y connecting the pulse and current output. PROFIUS-P interface: PROFIUS-P in accordance with N Volume 2, IC (MP), galvanically isolated Current consumption = 15 m FD (Fault Disconnection lectronic) = 0 m Data transmission rate: Supported baudrate = kit/s Signal encoding = Manchester II Function blocks: 1 x nalog Input, 1 x Totalizer Output data: Volume flow, Calculated mass flow, Corrected volume flow, Totalizer Input data: mpty pipe detection (ON/OFF), Control totalizer us address adjustable via DIP-switches at the measuring device FOUNDTION Fieldbus interface: FOUNDTION Fieldbus H1, IC , galvanically isolated Current consumption available on request Signal encoding = Manchester II FD (Fault Disconnection lectronic) = 0 m Data transmission rate: Supported baudrate = kit/s Function blocks: 2 x nalog Input, 1 x Digital Output, 1 x PID Output data: Volume flow, calculated Mass flow, corrected Volume flow, Totalizer Input data: mpty pipe detection (ON/OFF), Reset totalizer Signal on alarm Current output: error response can be selected (e.g. in accordance with NMUR Recommendation N 43) Pulse output: error response can be selected Status output: not conducting in event of fault 4 ndress + Hauser

5 Load R [ ] R [ ] Non-x x d U [ ] S V R [ ] x i U [ ] S V The load can be calculated as follows: U S UKl U S UKl R = = 3 I 10 0,022 max The grey shaded area indicates the permissible load (for HRT: min. 250 ) R Load US Supply voltage Non-x = V DC, x i = V DC, x d = V DC Imax Output current ( 22,6 m) F06-72xxxxxx-05-xx-xx-en-001 Low flow cut off Galvanic isolation Switch points for low flow cut off can be selected as required The electrical connections are galvanically isolated from one another. ndress + Hauser 5

6 lectrical connection Power supply D C C lectrical connection Prowirl 72 - HRT: Power supply, current output - PROFIUS-P: 1 = P+, 2 = P - FOUNDTION Fieldbus: 1 = FF+, 2 = FF Optional pulse output, can also be operated as status output (except PROFIUS-P and FOUNDTION Fieldbus) C Ground terminal (relevant for remote version) D PFM wiring (pulse-frequency modulation) F06-72xxxxxx xx-000.eps Supply voltage Cable entry Power supply failure Non-x: V DC (with HRT V DC) x i: V DC (with HRT V DC) x d: V DC (with HRT V DC) PROFIUS-P and FOUNDTION Fieldbus Non-x: V DC x i: V DC x d: V DC Current consumption PROFIUS-P: 15 m, FOUNDTION Fieldbus: on request Power supply and signal cables (outputs): Cable entry M20 x 1.5 ( mm) Thread for cable entry: ½" NPT, G ½" (not for remote version) Fieldbus connector Totalizer stops at the last value determined (can be configured) ll settings are kept in the PROM rror messages (incl. value of operated hours counter) are stored Performance characteristics Reference operating conditions Maximum measured error rror limits following ISO/DIN 11631: C, bar, Calibration rig traccable to national standards Calibration with the corresponding process connection of the respective norms Liquid: < 0.75% o.r. for Re > < 0.75% o.f.s for Re between Gas/steam: < 1% o.r. for Re > < 1% o.f.s for Re between o.r. = Of reading, o.f.s = Of full scale, Re = Reynolds number Repeatability ±0.25% o.r. (of reading) 6 ndress + Hauser

7 PROline Prowirl 72 F, W Operating conditions: installation Installation instructions Vortex meters require a fully developed flow profile as a prerequisite for correct volume flow measurement. For this reason, please note the following points when installing the device: Orientation The device can generally be installed in any position in the piping. In the case of liquids, upward flow is prefered in vertical pipes to avoid partial pipe filling (see orientation ). In the case of hot fluids (e.g. steam or fluid temperature 200 C), select orientation C or D so that the permitted ambient temperature of the electronics is not exceeded. Orientations and D are recommended for very cold fluid (e.g. liquid nitrogen). Orientations, C and D are possible with horizontal installation. The arrow indicated on the device must always point in the direction of flow in all mounting orientations. Caution! If fluid temperature is 200 C, orientation is not permitted for the wafer version (Prowirl 72 W) with a nominal diameter of DN 100 and DN 150. C D Possible orientations of the device F06-7xxxxxxx-04-xx-xx-xx-002 Minimum spacing and cable length Please pay attention to the following dimensions when installing in piping: Minimum spacing in all directions = 100 mm () Necessary cable length L mm L Minimum spacing and cable length F06-7xxxxxxx xx-xx-000 ndress + Hauser 7

8 PROline Prowirl 72 F, W Rotating the electronics housing and the display The electronics housing can be rotated continuously 360 on the housing support. The display unit can be rotated in 45 steps. This means you can read off the display comfortably in all orientations. Piping insulation When insulating, please ensure that a sufficiently large area of the housing support is exposed. The uncovered part serves as a radiator and protects the electronics from overheating (or undercooling). The maximum insulation height permitted is illustrated in the diagrams. These apply equally to both the compact version and the sensor in the remote version = Flanged version 2 = Wafer version F06-7xxxxxxx xx-001 Wafer version mounting set The centering rings supplied with the wafer style meters are used to mount and center the instrument. mounting set consisting of tie rods, seals, nuts and washers can be ordered separately Mounting wafer version 1 = Nut 2 = Washer 3 = Tie rod 4 = Centering ring (is supplied with the device) 5 = Seal F06-7xxxxxxx xx ndress + Hauser

9 PROline Prowirl 72 F, W Inlet and outlet run s a minimum, the inlet and outlet runs shown below must be observed to achieve the specific accuracy of the device. The longest inlet and outlet run shown must be observed if two or more flow disturbances are present x DN 5 x DN 2 18 x DN 5 x DN x DN 5 x DN 40 x DN 5 x DN 5 25 x DN 5 x DN 6 50 x DN 5 x DN Minimum inlet and outlet runs with various flow obstructions = Inlet run = Outlet run 1 = Reduction 2 = xtension 3 = 90 elbow or T-piece 4 = 2 x 90 elbow, 3-dimensional 5 = 2 x 90 elbow 6 = Control valve F06-7xxxxxxx-04-xx-xx-xx-000 Note! specially designed perforated plate flow conditioner can be installed if it is not possible to observe the inlet runs required (see Page 10). Outlet runs with pressure and temperature measuring points If pressure and temperature measuring points are installed after the device, please ensure there is a large enough distance between the device and the measuring point so there are no negative effects on the vortex shedding. PT TT x DN x DN PT = Pressure measuring point TT = Temperature measuring point F06-7xxxxxxx-04-xx-xx-xx-003 ndress + Hauser 9

10 PROline Prowirl 72 F, W Perforated plate flow conditioner specially designed perforated plate flow conditioner, available from ndress+hauser, can be installed if it is not possible to observe the inlet runs required. The flow conditioner is fitted between two piping flanges and centered with mounting bolts. Generally, this reduces the inlet run required to 10 x DN with complete accuracy. 2 x DN 8 x DN 5 x DN Flow conditioner F06-7xxxxxxx-04-xx-xx-xx-001 The pressure loss for flow conditioners is calculated as follows: p [mbar] = ρ [kg/m³] v² [m/s] xamples of pressure loss for flow conditioner xample with steam p = 10 bar abs t = 240 C ρ = 4.39 kg/m³ v = 40 m/s p = ² = 59.7 mbar xample with H 2 O condensate (80 C) ρ = 965 kg/m³ v = 2.5 m/s p = ² = 51.3 mbar Operating conditions: environment mbient temperature range Compact version: C Display can be read between 20 C C Remote version: Sensor C Transmitter C Display can be read between 20 C C When mounting outside, protect from direct sunlight with a protective cover (order number ), especially in warmer climates with high ambient temperatures. Storage temperature C Degree of protection IP 67 (NM 4X) according to N Vibration resistance cceleration up to 1 g, Hz, following IC lectromagnetic compatibility (MC) ccording to N 61326/1 and NMUR Recommendation N ndress + Hauser

11 Operating conditions: process Medium temperature range DSC sensor (differential switched capacitor) capacitive sensor: DSC standard sensor C DSC high/low temperature sensor C DSC sensor Inconel (PN , Class 600, C JIS 40K and Dualsens version) DSC sensor lloy C C Seal: Graphite C Viton C Kalrez C Gylon (PTF) C Medium pressure Pressure-temperature curve according to DIN (stainless steel) PN Prowirl 72 W and 72 F PN Prowirl 72 F bar PN 40 PN 25 PN 16 PN PN C bar PN 160 PN 100 PN PN C F06-7xxxxxxx-05-xx-xx-xx-000 Pressure-temperature curve according to NSI 16.5 and JIS 2238 (stainless steel) NSI 16.5: Class Prowirl 72 W and 72 F Class 600 Prowirl 72 F JIS 2238: K Prowirl 72 W and 72 F 40K Prowirl 72 F Class bar Cl Cl Cl C bar 40 K 20 K 10 K K C F06-7xxxxxxx-05-xx-xx-xx-001 Continued on next page. ndress + Hauser 11

12 PROline Prowirl 72 F, W Pressure-temperature curve according to DIN, NSI 16.5 and JIS 2238 (lloy C-22) PN , Class , K Prowirl 72 F bar PN 40 PN Class 300 Class K 10 K C F06-7xxxxxxx-05-xx-xx-xx-002 Pressure loss The pressure loss can be determined with the aid of the pplicator, a software for selection and sizing of flowmeters. The software is available both via Internet ( and on a CD-ROM for local PC installation. Mechanical construction Design, dimensions Dimensions of transmitter, remote version 232 (226)* Ø 8.6 (M8) (163)* 345 (368)* * The following dimensions differ depending on the version: The dimension 232 mm changes to 226 mm in the blind version (without local operation). The dimension 150 mm changes to 163 mm in the x d version. The dimension 345 mm changes to 368 mm in the x d version. F06-72xxxxxx xx-000.eps 12 ndress + Hauser

13 NICHT UNTR SPNNUNG ÖFFNN N IN XPLOSIV TMOSPHR TIGHT W H S WRNUNG VRTISSMNT WRNING LIV PROline Prowirl 72 F, W Dimensions of Prowirl 72 W Wafer version for flanges according to: DIN 2501, PN NSI 16.5, Class , Sch40 JIS 2238, K, Sch (142)* ** ** H H 42.5 d D C 151 (144)* 161 PS OUVRIR OUS TNSION N CIRCUIT KP H + 7 Dimensions: = Standard and x i version = Remote version C = x d version (transmitter) * The following dimensions change as follows in the blind version (without local operation): Standard and x i version: the dimension 149 mm changes to 142 mm in the blind version. x d version: the dimension 151 mm changes to 144 mm in the blind version. ** The dimension depends on the cable gland used. F06-72xxxxxx xx-000 Note! In the following tables, dimension H increases by 29 mm in the version with extended temperature range (high temperature version) and in the version with a DSC sensor made of lloy C-22. The weight data refer to the compact version. The weight increases by 0.5 kg for the version with extended temperature range. DN d D H Weight DIN/JIS NSI [mm] [mm] [mm] [kg] 15 ½" " ½" " " " " ndress + Hauser 13

14 NICHT UNTR SPNNUNG ÖFFNN N IN XPLOSIV TMOSPHR TIGHT W H S WRNUNG VRTISSMNT WRNING LIV PROline Prowirl 72 F, W Dimensions of Prowirl 72 F Flanged version according to: DIN 2501, R a = µm raised face according to DIN 2526 form C for pressure ratings PN , raised face according to DIN 2526 form for pressure ratings PN NSI 16.5, Class , R a = µin JIS 2238, K, R a = µin 149 (142)* ** ** H H 42 D d X L C 151 (144)* 161 PS OUVRIR OUS TNSION N CIRCUIT KP H + 7 = Standard and x i version = Remote version C = x d version (transmitter) * The following dimensions change as follows in the blind version (without local operation): Standard and x i version: the dimension 149 mm changes to 142 mm in the blind version. x d version: the dimension 151 mm changes to 144 mm in the blind version. ** The dimension depends on the cable gland used. F06-72xxxxxx xx-001 Note! In the following tables, dimension H increases by 29 mm in the version with extended temperature range (high temperature version) and in the version with a DSC sensor made of lloy C-22. The weight data refer to the compact version. The weight increases by 0.5 kg for the version with extended temperature range. 14 ndress + Hauser

15 Table: dimensions of Prowirl 72 F according to DIN 2501 DN Pressure rating d [mm] D [mm] H [mm] L [mm] x [mm] Weight [kg] 15 PN PN PN PN PN PN PN PN PN PN PN PN PN PN PN PN PN PN PN PN PN PN PN PN PN PN PN PN PN PN PN PN PN PN PN PN PN PN ndress + Hauser 15

16 Table: dimensions of Prowirl 72 F according to NSI 16.5 DN Pressure rating d [mm] D [mm] H [mm] L [mm] x [mm] Weight [kg] ½" Schedule 40 Cl Cl Cl Cl Cl " Schedule 40 Cl Cl Cl Cl Cl ½" Schedule 40 Cl Cl Cl Cl Cl " Schedule 40 Cl Cl Cl Cl Cl " Schedule 40 Cl Cl Cl Cl Cl " Schedule 40 Cl Cl Cl Cl Cl " Schedule 40 Cl Cl Cl Cl Cl " Schedule 40 10" Schedule 40 12" Schedule 40 Cl Cl Cl Cl Cl Cl ndress + Hauser

17 Table: dimensions of Prowirl 72 F according to JIS 2238 DN Pressure rating d [mm] D [mm] H [mm] L [mm] x [mm] Weight [kg] Schedule 40 20K K K Schedule 40 20K K K Schedule 40 20K K K Schedule 40 10K K K K K Schedule 40 10K K K K K Schedule 40 10K K K K K Schedule 40 10K K K K K Schedule Schedule Schedule 40 10K K K K K K ndress + Hauser 17

18 NICHT UNTR SPNNUNG ÖFFNN N IN XPLOSIV TMOSPHR TIGHT W H S WRNUNG VRTISSMNT WRNING LIV PROline Prowirl 72 F, W Dimensions of Prowirl 72 F, Dualsens version DIN 2501, R a = µm raised face according to DIN 2526 form C for pressure ratings PN , raised face according to DIN 2526 form for pressure ratings PN NSI 16.5, Class , R a = µin JIS 2238, K, R a = µin 149 (142)* ** ** H H 42.5 D d 2 x H H 85 x C 151 (144)* L 161 PS OUVRIR OUS TNSION N CIRCUIT KP H + 7 = Standard and x i version = Remote version C = x d version (transmitter) * The following dimensions change as follows in the blind version (without local operation): Standard and x i version: the dimension 149 mm changes to 142 mm in the blind version. x d version: the dimension 151 mm changes to 144 mm in the blind version. ** The dimension depends on the cable gland used. F06-72xxxxxx xx ndress + Hauser

19 Note! The weight data refer to the compact version. The weight increases by 0.5 kg for the version with extended temperature range. Table: dimensions of Prowirl 72 F Dualsens version according to DIN 2501 DN Pressure d D H L x Weight DIN/JIS rating [mm] [mm] [mm] [mm] [mm] [kg] PN PN PN PN PN PN PN PN PN PN PN PN PN PN PN PN PN PN PN PN PN Table: dimensions of Prowirl 72 F Dualsens version according to NSI 16.5 DN Pressure rating d D H L x Weight NSI [mm] [mm] [mm] [mm] [mm] [kg] Schedule 40 Cl Cl ½" 2" 3" Cl Cl Cl Schedule 40 Cl Cl Cl Cl Schedule 40 Cl Cl Cl Cl Cl ndress + Hauser 19

20 DN Pressure rating d D H L x Weight NSI [mm] [mm] [mm] [mm] [mm] [kg] Schedule 40 Cl Cl " 6" Cl Cl Cl Schedule 40 Cl Cl Cl Cl Cl Table: dimensions of Prowirl 72 F Dualsens version according to JIS 2238 DN Pressure rating d D H L x Weight DIN/JIS [mm] [mm] [mm] [mm] [mm] [kg] 40 Schedule 40 20K K K Schedule 40 10K K K K K Schedule 40 10K K K K K Schedule 40 10K K K K K Schedule 40 10K K K K K ndress + Hauser

21 Dimensions of flow conditioner according to DIN/NSI s Flow conditioner according to DIN/NSI, material (316L) F06-7xxxxxxx xx-001 Table: dimensions of flow conditioner DN 15 / ½" 25 / 1" 40 / 1½" s [mm] DIN PN Weight in [kg] PN PN PN PN NSI Cl Weight in [kg] Cl / 2" 80 / 3" 100 / 4" 150 / 6" 200 / 8" 250 / 10" 250 / 12" Weight Weight of Prowirl 72 W see dimension table on Page 13. Weight of Prowirl 72 F see dimension tables on Page 14 ff. Weight of Prowirl 72 F, Dualsens version see dimen. tab. on Page 18 ff. Weight of flow conditioner according to DIN/NSI see dimension table on Page 21. Material Transmitter housing: Powder-coated die-cast aluminium Sensor: Flanged version: Stainless steel, (351-CF3M), in conformity with NC MR 0175; lloy C-22, ( 494-CX2MW/N 26022) Wafer version: Stainless steel, (351-CF3M), in conformity with NC MR 0175 DSC sensor (differential switched capacitor; capacitive sensor): Wetted parts (marked as wet on the DSC sensor flange): Standard for pressure ratings up to PN 40, Cl 300, JIS 40 K (apart from Dualsens version): Stainless steel (316L), in conformity with NC MR 0175 Higher pressure ratings and Dualsens version: Inconel /N (637) (Inconel 718), in conformity with NC MR 0175 lloy C-22 sensor: lloy C-22, /N 06022, in conformity with NC MR 0175 Non-wetted parts: Stainless steel (CF3) Support: Stainless steel, (CF8) Seal: Graphite (Grafoil) Viton Kalrez 6375 Gylon (PTF) 3504 ndress + Hauser 21

22 Human interface Display elements Operating elements (HRT) Remote operation Liquid crystal display, double-spaced, plain text display, 16 characters per line Display can be configured individually, e.g. for measured variables and status values, totalizers Local operation with three keys (,,) Quick Setup for quick commissioning Operating elements accessible also in x-zones Remote operation possible via: HRT PROFIUS-P FOUNDTION Fieldbus ndress+hauser Service Protocol Certificates and approvals C mark The device is in conformity with the statutory requirements of the C Directives. ndress+hauser confirms successful testing of the device by affixing the C mark. x-approval x i: TX/CNLC II1/2G, x ia IIC T1...T6 (T1...T4 for PROFIUS-P and FOUNDTION Fieldbus) II1G, x ia IIC T1...T6 (T1...T4 for PROFIUS-P and FOUNDTION Fieldbus) II2G, x ia IIC T1...T6 (T1...T4 for PROFIUS-P and FOUNDTION Fieldbus) II3G, x n IIC T1...T6 X (T1...T4 X for PROFIUS-P and FOUNDTION Fieldbus) FM Class I/II/III Div. 1/2, Group...G CS Class I/II/III Div. 1/2, Group...G Class II Div. 1, Group...G Class III x d: TX/CNLC II1/2G, x d [ia] IIC T1...T6 (T1...T4 for PROFIUS-P and FOUNDTION Fieldbus) II2G, x d [ia] IIC T1...T6 (T1...T4 for PROFIUS-P and FOUNDTION Fieldbus) FM Class I/II/III Div. 1, Groups...G CS Class I/II/III Div. 1,2 Groups...G Class II Div. 1, Groups...G Class III More information on the x-approvals can be found in the separate x-documentation. Pressure measuring device approval Certification FOUNDTION Fieldbus Devices with a nominal diameter smaller than or equal to DN 25 correspond to rticle 3 (3) of the C Directive 97/23/C (Pressure quipment Directive). For larger nominal diameters, certified flowmeters to Category III are optionally also available if necessary (depends on fluid and operating pressure). ll devices are applicable for all fluids and instable gases on principle and have been designed and manufactured in accordance to sound engineering practice. The flowmeter has successfully passed all test procedures and is certified and registered by the Fieldbus FOUNDTION. The device thus meets all the requirements of the specifications following: Certified according to FOUNDTION Fieldbus Specification The device meets all the specifications of the FOUNDTION Fieldbus-H1 Interoperability Test Kit (ITK), revision status 4.0 (device certification no. available on request): The device can also be operated with certified devices of other manufacturers Physical Layer Conformance Test of the Fieldbus FOUNDTION 22 ndress + Hauser

23 Certification PROFIUS-P Other standards and guidelines The flowmeter has successfully passed all test procedures and is certified and registered by the PNO (PROFIUS User Organisation). The device thus meets all the requirements of the specifications following: Certified according to PROFIUS-P profile version 3.0 (device certification number available on request) The device can also be operated with certified devices of other manufacturers (interoperability) N 60529: Degrees of protection by housing (IP code). N 61010: Protection measures for electrical equipment for measurement, control, regulation and laboratory procedures. N 61326/1: lectromagnetic compatibility (MC requirements). NMUR N 21: lectromagnetic compatibility (MC) of industrial process and laboratory control equipment. NMUR N 43: Standardisation of the signal level for the breakdown information of digital transmitters with analogue output signal. NC Standard MR0175: Standard Material Requirements - Sulfide Stress Cracking Resistant Metallic Materials for Oilfield quipment. VDI 2643: Measurement of fluid flow by means of vortex flowmeters. ccessories Wafer version mounting set Spare parts as per separate price list Replacement transmitter Prowirl 72 RMS-621 steam computer Compart DXF 351 flow computer Flow conditioner HRT Communicator DXR 275 handheld terminal ctive barrier preline RN 221 N Pressure transducer Cerabar T resp. Cerabar S (PROFIUS-P, FOUNDTION Fieldbus) Thermoresistance Omnigrad TST Process display RI 250, RI 251 Field display RI 261 resp. RID 261 (PROFIUS-P) pplicator FieldTool Fieldgate FX 520 Documentation Operating Instructions PROline Prowirl 72 Operating Instructions PROline Prowirl 72 PROFIUS-P Operating Instructions PROline Prowirl 72 FOUNDTION Fieldbus Related x-documentation System Information PROline Prowirl 72 Related documentation for Pressure quipment Directive ndress + Hauser 23

Vortex Flow Measuring System PROline prowirl 72

Vortex Flow Measuring System PROline prowirl 72 Technical Information TI 062D/06/en No. 50103356 Vortex Flow Measuring System PROline prowirl 72 Reliable Flow Measurement of Gas, Steam and Liquids Application For measuring the volume flow of steam,

More information

Proline Prowirl 73. Technical Information. Reliable Flow Measurement of Gas, Steam and Liquids. Two-Wire Saturated Steam Mass Flowmeter.

Proline Prowirl 73. Technical Information. Reliable Flow Measurement of Gas, Steam and Liquids. Two-Wire Saturated Steam Mass Flowmeter. Technical Information Proline Prowirl 73 Reliable Flow Measurement of Gas, Steam and Liquids. Two-Wire Saturated Steam Mass Flowmeter. pplication For universal volume or mass flow measurement of steam,

More information

Vortex Flow Measuring System PROline prowirl 72

Vortex Flow Measuring System PROline prowirl 72 Technical Information TI 062D/24/ae Vortex Flow Measuring System PROline prowirl 72 Reliable Flow Measurement of Gas, Steam and Liquids pplication For measuring the volume flow of steam, gases and liquids.

More information

Full Metal Variable Area Flow Meter and Counter

Full Metal Variable Area Flow Meter and Counter Full Metal Variable rea Flow Meter and Counter for horizontal and vertical mounting measuring monitoring analysing Special versions up to 600 bar Measuring range: 10-100...00-000 L/h water 0.3-3.0...-0

More information

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up

More information

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar

More information

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27 Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for

More information

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181 Siemens AG 09 SITRANS F flowmeters System information Overview Siemens offers two types of ultrasonic flowmeters, in-line flowmeters and clamp-on flowmeters. This offers the end user the maximum flexibility

More information

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,

More information

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,

More information

Reflex-Radar BM 100 A

Reflex-Radar BM 100 A KROHNE 09/2001 7.02317.22.00 GR/PRINTO Reflex-Radar The universal TDR level gauge for liquids, solids and interface Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output

More information

Direct-operated 2/2-way compact solenoid valves Type EV210A

Direct-operated 2/2-way compact solenoid valves Type EV210A Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together

More information

DOG-1/-3. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air : 120 C. p max. : PN 40; t max

DOG-1/-3. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air : 120 C. p max. : PN 40; t max Oscillation Flowmeter for gases measuring monitoring analysing DOG1/3 Measuring ranges: 0.2 20... 200 20000 m 3 /h air p max : PN 40; t max : 120 C Connection: flange DN 25... DN 400 Material: cast iron,

More information

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels TF 0 / TF 0-Ex Field mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.69 EN USA Input Resistance thermometer (,, wire circuit) Thermocouples

More information

Solenoid valves 2/2-way direct-operated type EV210A

Solenoid valves 2/2-way direct-operated type EV210A MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valves 2/2-way direct-operated type EV210A EV210A covers a wide range of small, direct-operated 2/2-way solenoid valves for use in industrial machinery.

More information

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO. DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link

More information

Direct-operated 2/2-way solenoid valves Type EV210B

Direct-operated 2/2-way solenoid valves Type EV210B Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

Ultrasonic Gas Flow Meter

Ultrasonic Gas Flow Meter P r o d u c t i n f o r m at i o n FLOWSIC600 Ultrasonic Gas Flow Meter For custody transfer and process applications Analyzers and Process Instrumentation FLOWSIC600 For Custody Transfer and Process Applications

More information

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement

More information

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level

More information

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

Electromagnetic Flowmeter

Electromagnetic Flowmeter Overview Flokal B.V. smart electromagnetic flow meter is hallmarked by its high performance and reliability that are based on successful, field-proven technology. It s being widely used in industries such

More information

Pressure transmitters for industrial applications MBS 32 and MBS 33

Pressure transmitters for industrial applications MBS 32 and MBS 33 Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer

More information

Coriolis Mass Flow Measurement System promass 60 (HART)

Coriolis Mass Flow Measurement System promass 60 (HART) Technical Information TI 029D/06/en No. 5006899 Coriolis Mass Flow Measurement System promass 60 (HART) Cost-effective mass flow measurement for liquids and gases Flexible System The system can be customised

More information

Operating Instructions for Digital Manometer. Model: MAN-SD

Operating Instructions for Digital Manometer. Model: MAN-SD Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5

More information

VersaFlow Ultrasonic clamp-on Flowmeter Specifications

VersaFlow Ultrasonic clamp-on Flowmeter Specifications VersaFlow Ultrasonic clamp-on Flowmeter Specifications 34-VF-03-14 September 2009 Clamp-On Technology HONEYWELL S VersaFlow stands for continuity and long term reliability. Flow measurement can be done

More information

Operating instructions Pressure sensor PN / / 2007

Operating instructions Pressure sensor PN / / 2007 Operating instructions Pressure sensor PN42 704298 / 00 0 / 2007 Contents afety instructions... 3 2 Function and features... 4 3 Function... 5 3. witching function... 5 4 Installation... 5 5 Electrical

More information

Application PN 16 / 40 DN Product features. Compact overall height Body shape gives optimum flow characteristic

Application PN 16 / 40 DN Product features. Compact overall height Body shape gives optimum flow characteristic pplication Control of gases, vapours and liquids. The modular concept of valve, multi spring actuator and digital FOXBORO/Eckardt positioner Type SRD 992 facililates trouble free expansion to allow for

More information

ISEmax CAM40/CAS40. Technical Information

ISEmax CAM40/CAS40. Technical Information Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works

More information

PHOENIX CONTACT - 04/2016. Features

PHOENIX CONTACT - 04/2016. Features Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.

More information

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22) .2 Ex-Ceiling light fittings AB 8 / AB 5 LED / AB 5 / AB 12 NAV 7 (Zone 1, 2, 21, 22) The wall and ceiling light fixtures for particularly difficult operating conditions The impact-resistant and flameproof

More information

Flow Measurement. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/22 Siemens FI

Flow Measurement. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/22 Siemens FI Function All are based on Faraday s law of induction: U M = B v d k U M = Measured voltage induced in the medium perpendicular to the magnetic field and the flow direction. The voltage is tapped at two

More information

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8. TF / TF -Ex Field mounted temperature transmitters, PROFIBUS PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN P R O F I PROCESS FIELD BUS B U S Input Resistance thermometer (,, -wire

More information

Integral V-Cone Flowmeter VD series

Integral V-Cone Flowmeter VD series TRANSMITTER DIRECTLY MOUNTED! SIMPLE AND EASY INSTALLATION Integral V-Cone Flowmeter VD series OUTLINE VD series Integral V-Cone Flowmeter is a differential pressure type flowmeter. Unlikely to existing

More information

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet High-efficiency Circulator Pump Rio-Eco N / Rio-Eco Z N Type Series Booklet Legal information/copyright Type Series Booklet Rio-Eco N / Rio-Eco Z N KSB Aktiengesellschaft All rights reserved. The contents

More information

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18 erie B. Flanged ductile iron ball valve BRanDOni made in E U R O P E Application fields WATER CONdITIONING GA EATING INdUTRY FIRE FIGTING www.brandoni.it erie B. eries B. valves are shut-off ball valves

More information

SmartLine Radar Level Meter RM70

SmartLine Radar Level Meter RM70 Page 1 of 5 SmartLine Radar Level Meter Model Selection Guide Reliable measurement in difficult process conditions +/- 3 mm / +/-0.12" standard accuracy Operates up to a flange temperature of 200 0 C /

More information

Target Insertion Flowmeter

Target Insertion Flowmeter Principle of Operation Flow is measured in terms of dynamic force acting on a target (solid disk) in the flow stream. Hermetically sealed, bonded strain gages in a bridge circuit configuration mounted

More information

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30 eries Features Best pressure transmission solution for small and middle sized project such as indoor heating and air conditioning, water and sewer, or incinerator, etc. Improves noise resistance and minimize

More information

Oscillation Flow Meter for Gases

Oscillation Flow Meter for Gases Oscillation Flow Meter for Gases measuring monitoring analysing Measuring ranges: 0.2 to 000 m 3 /h air pmax: PN 0, tmax: 0 C Connection: flange DN 25 DN 00 : Cast Iron, steel or stainless steel Accuracy:

More information

3.1 HP 111 HIGH-PERFORMANCE BUTTERFLY VALVE HP 111 TECHNICAL DATA

3.1 HP 111 HIGH-PERFORMANCE BUTTERFLY VALVE HP 111 TECHNICAL DATA HIGH-PERFORMANCE BUTTERFY VAVE HP 111 Wafer type butterfly valve in double-eccentric construction. Reliable sealing even with extreme temperature and pressure conditions. TECHNICA DATA Nominal diameter:

More information

VK2 volume flow controller Overview

VK2 volume flow controller Overview New option with sound attenuator Maintenance-free VK2 volume flow controller that operates without an auxiliary power supply, for ventilation and air conditioning systems. Adjustable on site. Outstanding

More information

Coriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM

Coriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM MAXIFO TM Features MaxiFlo Coriolis Mass Flowmeter series MCM is a mass flow meter that measures mass flow, density and temperature of liquids, slurries and gases. And it even measures oil content in water.

More information

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

CALYS 80P. Field pressure calibrator with high accuracy 0.01% Field pressure calibrator with high accuracy 0.01% CALYS 80P is a field pressure calibrator within CALYS range with high accuracy of 0.01%. Description CALYS 80P is a field pressure calibrator within CALYS

More information

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application Type 2657...59 DN 10 up to 80 mm; Plastic; 2/2 way dvantages/benefits ntegrated pilot valves, position feed-back and limit switches available Customized system solutions with Burkert valves & sensors With

More information

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components: SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine

More information

Online data sheet FLOWSIC600-XT GAS FLOW METERS

Online data sheet FLOWSIC600-XT GAS FLOW METERS Online data sheet T MTH F H I J K L M N O P Q R S T Ordering information Type Part no. On request The exact device specifications and performance data of the product may deviate from the information provided

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 07 Overview Function SITRANS LH00 Transmitter for hydrostatic level U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/

More information

Technical specification FLUXUS F502TE

Technical specification FLUXUS F502TE Technical specification FLUXUS F502TE Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate Precise and intelligent energy measuring

More information

TSK. Flap-Type Flowmeter. Range: to GPM Accuracy: ± 2.5% of Full Scale P max. : 580 PSI T max

TSK. Flap-Type Flowmeter. Range: to GPM Accuracy: ± 2.5% of Full Scale P max. : 580 PSI T max Flap-Type Flowmeter measuring monitoring analyzing TSK Range: 6.6...26.4 to 880...6600 GPM Accuracy: ± 2.5% of Full Scale P max : 580 PSI T max : -40 572 F Connection: Wafer Flange 1.5" 20" ASME Material:,

More information

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014 Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM8004 80003223 / 00 05 / 2014 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...4 3 Functions and features...5

More information

CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis mass flowmeter

CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis mass flowmeter Data Sheet DS/FCB100/FCH100-EN Rev. D CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis mass flowmeter High precision measurement of mass and volume flow, density, temperature and concentration with

More information

PRODUCT CATALOGUE PREssURE switch

PRODUCT CATALOGUE PREssURE switch PRODUCT CATALOGUE PREssURE switch w w w. p a a b. c o m Pressure AT THe HIGHesT LeVeL Successful mediumsized companies are not successful because they are active in many areas, but rather because they

More information

Flow Meter FVone-NP-CA. FVone-NP-CA 11 (Plug-in type) (Screw-in type) Recommended for: DN 20 DN 80 Required accessory: Cable type 31.

Flow Meter FVone-NP-CA. FVone-NP-CA 11 (Plug-in type) (Screw-in type) Recommended for: DN 20 DN 80 Required accessory: Cable type 31. FVone-NP- 00/ (Push-in type) Recommended for: DN and bigger Required accessory: Threaded installation bush able type Optional accessory: PTFE sealing ring Locking set FVone-NP- 0/0 (Screw-in type) Recommended

More information

Absolute encoders multiturn

Absolute encoders multiturn elektronischer electronic multiturn, Multiturn, magnetic magnetisch Sendix M66 / M68 (shaft / hollow shaft) The Sendix M6 with Energy Harvesting Technology is an electronic multiturn encoder in miniature

More information

3.2 HP 114 HIGH PERFORMANCE BUTTERFLY VALVE HP 114 TECHNICAL DATA

3.2 HP 114 HIGH PERFORMANCE BUTTERFLY VALVE HP 114 TECHNICAL DATA ug type butterfly valve in double-eccentric construction. Reliable sealing even with extreme temperature and pressure conditions. TECHNICA DATA Nominal diameter: 0 larger nominal diameter on request Face-to-face:

More information

Pressure Transmitter ED 701

Pressure Transmitter ED 701 Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation

More information

Relative pressure transmitter type 520

Relative pressure transmitter type 520 Relative pressure transmitter type 520 Pressure range The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the pressure measuring cell is fully

More information

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

THM80X Series  Feature Application. Temperature & Humidity / Flow Measuring Specialist THM80X Series Feature Application IP67 protection degree, rugged aluminum case, fit in variety harsh environment Capable of temperature compensation Linear adjustment temperature & humidity by computer,

More information

Capacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z

Capacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z Technical Information TI 271F/00/en Operating Instructions 017182-1000 Capacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z Transmitters for capacitance probes Application The electronic inserts

More information

Cooling Water Flow Regulator

Cooling Water Flow Regulator Temperature controlled, indirectly and directly actuated diaphragm valves / seat valves Port size G 3/8 to G DN 0 to DN 0 ontinuous regulation High accuracy No auxiliary energy required Technical data

More information

SPECIFICATION SS 51/9 400KV COUPLING CAPACITORS FOR POWER LINE CARRIER SYSTEM

SPECIFICATION SS 51/9 400KV COUPLING CAPACITORS FOR POWER LINE CARRIER SYSTEM INDEPENDENT POWER TRANSMISSION OPERATOR S.A. TNPRD/ SUBSTATION SPECIFICATION & EQUIPMENT SECTION January 2017 SPECIFICATION SS 51/9 400KV COUPLING CAPACITORS FOR POWER LINE CARRIER SYSTEM I. SCOPE This

More information

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006% ATEX documenting multifunction calibrator with high accuracy 0.006% is the top instrument of our range of ATEX documenting multifunction calibrators. Description is the top instrument of our range of ATEX

More information

Volumetric Flow Measurement

Volumetric Flow Measurement Volumetric Flow Measurement TVF Series Vortex Flow Meter Xi an Tosilon Automation Co., Ltd No.299, Daqing Rd, Lianhu District, Xi'an Shaanxi, China Tel: +86-29-8823 8550 info@tosilon.com; www.tosilon.com

More information

MX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E

MX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E OMPT ND USER FRIENDLY MX Series Metal Tube Type Variable rea Flowmeter OUTLINE MX Series flowmeter is the metal tube type variable area flowmeter having the unified face-to-face dimension. The compact

More information

Cartridge Valves Technical Information. Quick reference

Cartridge Valves Technical Information. Quick reference Quick reference Contents CPF0... 8. CP600-5... 8. CP60-5... 8. 066 handle kit... 8.5 MP06... 8.6 MP... 8.6 X05-FD0 Traction manifold... 8.9 X05-FD6 Traction manifold... 8.0 X05-FD0 Traction manifold...

More information

EX-EMERGENCY LIGHT FITTINGS

EX-EMERGENCY LIGHT FITTINGS EX-EMERGENCY LIGHT FITTINGS nllk 0...N 1-36 W Plastic version for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 N are conform to the requirements of the ATEX-Directive

More information

Installation guide 862 MIT / MIR

Installation guide 862 MIT / MIR Installation guide 862 MIT / MIR in combination with: 864 MTT or 863 MRT or (dual) spot element November 2005 Part no. 4416.232_Rev3 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100

More information

- compressed air plants (refrigerating/adsorption dryers) - granulate dryers - medical gases - non-corrosive gases, e. g. nitrogen

- compressed air plants (refrigerating/adsorption dryers) - granulate dryers - medical gases - non-corrosive gases, e. g. nitrogen INSTRUCTION MANUAL FA 510 The CS dew point sensor FA 510 with 3-wire technology 4 20 ma and RS 485 output enables a reliable and long-term stable monitoring of the dew point in industrial applications

More information

CoriolisMaster FCB430, FCB450, FCH430, FCH450 Coriolis mass flowmeter

CoriolisMaster FCB430, FCB450, FCH430, FCH450 Coriolis mass flowmeter Data Sheet DS/FCB400/FCH400-EN Rev. D CoriolisMaster FCB430, FCB450, FCH430, FCH450 Coriolis mass flowmeter High precision measurement of mass and volume flow, density, temperature and concentration with

More information

Mass Flow Meter and Controller

Mass Flow Meter and Controller ass Flow eter and Controller for Gases measuring monitoring analysing asuring range: 0-10 m N /min...0-500 N /min ccuracy: ±1.5% f.s. pmax 35 bar; tmax 50 C nalogue output: 0-5 V or 4-20 m Digital display

More information

50/60 Hz. ecocirc XL and XLplus. high efficiency WET ROTOR circulators. ErP 2009/125/EC

50/60 Hz. ecocirc XL and XLplus. high efficiency WET ROTOR circulators. ErP 2009/125/EC / Hz ecocirc XL and XLplus high efficiency WET ROTOR circulators FOR COMMERCIAL HEATING AND COOLING applications ErP 9/1/EC Cod. 1971 Rev. C Ed.11/1 Lowara, ecocirc, Xylect are trademarks of Xylem Inc.

More information

TF 212 / TF 212-Ex. Field mounted temperature transmitter, Profibus PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels. ABB Instrumentation

TF 212 / TF 212-Ex. Field mounted temperature transmitter, Profibus PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels. ABB Instrumentation TF / TF -Ex Field mounted temperature transmitter, Profibus PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN According to PROCESS FIELD BUS 0Input Resistance thermometer (,, -wire method)

More information

Page 1 of 16 Issue No. 0 of IECEx TUN X

Page 1 of 16 Issue No. 0 of IECEx TUN X Page 1 of 16 IECEx TR: DE/TUN/ExTR10.0002/00 IECEx QAR: DE/TUN/QAR06.0006/02 File reference: 10 204 55781-annex File reference: General product information: The electro pneumatic positioner SIPART PS2

More information

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes Examples of Application Flow measurements also in hazardous locations X zone 0 or zone 1 in clean rooms in air

More information

Operating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04

Operating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04 Operating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04 UK 80223776 / 00 11 / 2018 Contents 1 Preliminary note...3 2 Safety instructions...4 3 Functions and features...4 4 Function...5

More information

CALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05

CALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05 Modulating digital controller for heating and cooling series REGI ERED SI EN ISO 00:000 Cert. n FM UNI EN ISO 00:000 Cert. n 000 0/0 G replaces dp 0/0 Function The controller can be used with three-point

More information

DVZ. Vortex Flowmeter Compact. for low viscosity liquids. Range: l/min. Accuracy: ±2.5% of full scale. p max : 20 bar; t max : 80 C

DVZ. Vortex Flowmeter Compact. for low viscosity liquids. Range: l/min. Accuracy: ±2.5% of full scale. p max : 20 bar; t max : 80 C Vortex Flowmeter Compact for low viscosity liquids measuring monitoring analysing DVZ Range: 0.4. 000 l/min Accuracy: ±.% of full scale p max : 0 bar; t max : 80 C Connections: G ¼... G, ¼" NPT..." NPT

More information

FLOW SENSOR FOR LIQUID MEDIA Serie 210

FLOW SENSOR FOR LIQUID MEDIA Serie 210 FLOW SENSOR FOR LIQUID MEDIA Serie 0 Flow range 0.... 0 l/min Nominal diameters DN 6 / 8 / 0 / / 0 / Temperature measurement -0... + ÀC In comparison to the OEM flow sensor (type 00), the type 0 is available

More information

Surface-mounting Thermostats ATH Type Series

Surface-mounting Thermostats ATH Type Series Page 1/9 urface-mounting Thermostats ATH eries k enclosure protection IP 54 k tested to IN EN 14597 (replacing IN 3440) Brief description Thermostats control and monitor thermal processes. Instruments

More information

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol with PROFIBUS-PA procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application 00 II () G FISCO The SINEAX VK 66 is a temperature transducer for use in aumation systems

More information

Conductivity sensor for hygienic applications

Conductivity sensor for hygienic applications Conductivity sensor for hygienic applications Type 8221 can be combined with Perfect for demanding applications in the hygienic industry (CIP and SIP compatible) Variants available for usage over a wide

More information

INTERNATIONAL OIML D 25 DOCUMENT. Vortex meters used in measuring systems for fluids ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

INTERNATIONAL OIML D 25 DOCUMENT. Vortex meters used in measuring systems for fluids ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION INTERNATIONAL OIML D 25 DOCUMENT Edition 1996 (E) Vortex meters used in measuring systems for fluids Compteurs à vortex utilisés dans les ensembles de mesurage de fluides OIML D 25 Edition 1996 (E) ORGANISATION

More information

Level Sensor PanCake PR 6251 and Mounting Kit PR 6051

Level Sensor PanCake PR 6251 and Mounting Kit PR 6051 Level Sensor PanCake PR 6251 and Mounting Kit PR 6051 The space-saving solution for simple applications The sensors of the PR 6251 series have been specially designed for simple weighing of silos and horizontal

More information

Industrial Resistance Thermometers according to DIN Model MWD

Industrial Resistance Thermometers according to DIN Model MWD Industrial Resistance Thermometers according to DIN measuring monitoring analysing MWD OMeasuring O range: -98... +600 ºC O O Pt00 sensor: class A, class B, class /3, class /0, or O O Output: resistance

More information

Vortex Flow Meters. RVL Series Vortex Flow Meter

Vortex Flow Meters. RVL Series Vortex Flow Meter TM Vortex Meters RVL Series Vortex Meter pplications: Water/Wastewater I Water: Semiconductor, Institutional I Water Skids Semiconductor Equipment Slurry hemical Processing RINE FEERTE IN. ISO 900 : 000

More information

Online data sheet FLOWSIC600-XT GAS FLOW METERS

Online data sheet FLOWSIC600-XT GAS FLOW METERS Online data sheet FLOWSI600-XT GS FLOW MTRS FLOWSI600-XT GS FLOW MTRS F H I J K L M N O P Q R S T Ordering information Type Part no. FLOWSI600-XT On request The exact device specifications and performance

More information

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016 APPLICATIONS Moisture monitoring of air or gas (SF6) Suitable for indoor or outdoor Industrial, medical or aerospace fields HIGHLIGHTS High voltage circuit breakers commonly used for distribution and transmission

More information

Applicable Fluid. Accuracy. Flow Rate Range. Fluid Temperature. Fluid Viscosity. Connection Size. Flange Rating. Housing. Material. Blade.

Applicable Fluid. Accuracy. Flow Rate Range. Fluid Temperature. Fluid Viscosity. Connection Size. Flange Rating. Housing. Material. Blade. TOKICO TURINE METER GS-F211E- Overview Turbine meter has an excellent performance with its distinctive structure. Comparing with the flow meter using other method, it has compact and lighter design and

More information

Capacitive Sensors. Contents

Capacitive Sensors. Contents Contents Capacitive sensors detect the change in capacitance caused by the approach of an object. Their advantage lies in the ability to detect virtually any material, from metals to oils. 4.2 Definitions,

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET Series circulator pumps Contents Product data MAGNA and UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids 3 Type key Performance

More information

tekcor TKC Multivariable Coriolis Flow Sensors

tekcor TKC Multivariable Coriolis Flow Sensors Sensing the pulse of industry Technical Data Sheet & General Specifications tekcor TKC Multivariable Coriolis Flow Sensors The tekcor TKC Series principle was initiated by tekflo sensors engineers, who

More information

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet: abc instruments international FLT5A Thermometer Land Instruments International Dronfield, S18 1DJ England Telephone: (1246) 417691 Facsimile: (1246) 41585 Email: infrared.sales@landinst.com Internet: www.landinst.com

More information

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax , E X - L I G H T F I T T I N G S nllk 0... 1 - W All-plastic design for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 conform to the requirements of the ATEX-Directive

More information

VD1 CLC. Small Valves DIN-range with a higher k v -value

VD1 CLC. Small Valves DIN-range with a higher k v -value 0 EN - Small Valves DIN-range with a higher k v -value VD CLC Valve body made of brass, mat nickel-plated DN, DN 0 and DN Internally and externally threaded (Rp / R) conforming to ISO 7- Manual knob /

More information

v = 00,20 m/s Thermal Flow Sensors TA with thin-film sensor element Probes Probe guides Measuring tubes

v = 00,20 m/s Thermal Flow Sensors TA with thin-film sensor element Probes Probe guides Measuring tubes with thin-film sensor element Probes Probe guides Measuring tubes Examples of Application Flow measurements also in hazardous locations Ex zone 0 or zone 1 in clean rooms in air conditioning and ventilating

More information