SmartLine Radar Level Meter RM70
|
|
- Cathleen Robyn Goodman
- 6 years ago
- Views:
Transcription
1 Page 1 of 5 SmartLine Radar Level Meter Model Selection Guide Reliable measurement in difficult process conditions +/- 3 mm / +/-0.12" standard accuracy Operates up to a flange temperature of C / F and 40 bar / 580 psig Measuring range up to 80 m / 260 ft. Long antenna versions can be extended to suit any nozzle length PACTware and DTMs included as standard Optional second current output Directly-accessible graphic touchscreen/wizard (optional) Converter rotates Tripple barrier gas-tight protection available for working with dangerous gases (using pre-stressed fused glass) Instructions Select the desired key number. The arrow to the right marks the selection available. Make the desired selections from Tables I through V using the column below the proper arrow. A dot ( ) denotes availability. Table I I V - 4 _ Availability KEY NUMBER Description Selection TABLE I Level Meter Code 4 TABLE Approvals Material Process Connection and Antenna Antenna Antenna Extension 0 a ATEX G/D 1, 1/2, 2 Ex ia C T3...T6 2 a ATEX G/D 1/2, 2 Ex d[ia] C T3...T6 3 b FM IS CI. I Div. 1 Gr. A-G Dual Seal 6 c FM XP CI. I Div. 1 Gr. A-G Dual Seal 7 d ATEX 3G Ex na T3 T6 A a NEPSI Ex ia C T3...T6 E a NEPSI Ex d[ia] C T3...T6 F b CSA IS CI. I Div. 1 Gr. A-G Dual Seal H c CSA XP CI. I Div. 2 Gr. A-G Dual Seal K d IECEx Zone 0 Ex ia C T3 T6, Ex iad 20 M e IECEx Zone 0/1 Exd [ia] C T3 T6, Ex td [iad] A21/20 N b 316L / Drop PTFE (40 bar) - Drop PP (16 bar) - Hygienic PEEK (10 bar) _ 0 _ Hastelloy C-22 / _ 1 _ f 316L / / 100 bar _ 2 _ g Hastelloy C-22 / / 100 bar _ 3 _ h Horn DN 80 dia. 75 mm (2.95 inch) - long 3 k Horn DN 40 dia. 39 mm (1.54 inch) - long 4 k Horn DN 50 dia. 43 mm (1.69 inch) - long 5 k Horn DN 80 dia. 75 mm (2.95 inch) - long - with purging system 6 k Horn DN 40 dia. 39 mm (1.54 inch) - long - with purging system 7 k Horn DN 50 dia. 43 mm (1.69 inch) - long - with purging system 8 k Horn DN 100 dia. 95 mm (3.7 inch) - long F k Horn DN 100 dia. 95 mm (3.7 inch) - long - with purging system G k PEEK Hygienic antenna (FDA conform) H l DROP PTFE DN 80 long ( Ø 75 mm / 2.95 inch) -50 C C P m DROP PP DN 80 long ( Ø 75 mm / 2.95 inch) -50 C C S n Sheet Metal Horn DN 80 dia. 75 mm (2.95 inch) - long U k Sheet Metal Horn DN 100 dia. 95 mm (3.7 inch) - long V k Sheet Metal Horn DN 80 dia. 75 mm (2.95 inch) - long - with purging system W k Sheet Metal Horn DN 100 dia. 95 mm (3.7 inch) - long - with purging system X k Extension 105 mm (4.13 inch) _ 1 _ Extension 210 mm (8.26 inch) _ 2 _ Extension 315 mm (12.4 inch) _ 3 _ Extension 420 mm (16.54 inch) _ 4 _ Extension 525 mm (20.67 inch) _ 5 _ Extension 630 mm (24.80 inch) _ 6 _ Extension 735 mm (28.94 inch) _ 7 _ Extension 840 mm (33.07 inch) _ 8 _ Extension 945 mm (37.20 inch) _ A _ Extension 1050 mm (41.34 inch) _ B _ Flange plate protection (PP drop) for DN 80/100, 3" & 4", 80A & 100A _ P _ o Flange plate protection (PP drop) for DN 150, 6" & 8" _ R _ p Flange plate protection (PTFE drop) for DN 80/100, 3" & 4", 80A & 100A _ S _ o Flange plate protection (PTFE drop) for DN 150, 6" & 8" _ T _ p
2 Page 2 of 5 TABLE Feedthrough / Temperature / Sealing Gasket TABLE I Process Connection EN Process Connection ASME Process Connection Other Output Standard / -40 C +150 C / FKM/FPM for Non Ex Drop antennas X s Standard / -50 C +150 C / EPDM for Non-Ex Drop antennas Y s Standard: C (-40 0 F) C (302 0 F), 40 bar (580 psi) max. / FKM/FPM 0 t Standard: C (-4 0 F) C (302 0 F), 40 bar (580 psi) max. / Kalrez t Dual: Metaglas / C (-22 0 F) C (302 0 F), 40 bar (580 psi) / FKM/FPM 2 t Dual: Metaglas / C (-4 0 F) C (302 0 F), 40 bar (580 psi) / Kalrez t Standard: -50 C C / EPDM 4 t Dual Metaglas: -30 C C / EPDM 5 t Standard/-20 C +150 C / Without for Tri-Clamp, SMS, DIN A q Standard/-20 C +150 C / EPDM for Bio Control B r Standard/-20 C +150 C / FKM/FPM for Bio Control C r Standard / -40 C C / FKM/FPM (distance piece included) F t Standard / -20 C C / Kalrez 6375 (distance piece included) G t Metaglas / -30 C C / FKM/FPM (distance piece included) H t Metaglas / -20 C C / Kalrez 6375 (distance piece included) K t Selection ailability G1 1/2" A ISO _ DN 40 PN 40 Form B1 EN _ DN 50 PN 40 Form B1 EN _ DN 80 PN 40 Form B1 EN1092 Be certain to confirm the _ DN 100 PN 16 Form B1 EN1092 size of the antenna to the _ DN 100 PN 40 Form B1 EN1092 size of the tank opening. A 0 0 _ DN 150 PN 16 Form B1 EN1092 While it is possible to use B 0 0 _ DN 150 PN 40 Form B1 EN1092 all of the combinations C 0 0 _ DN 50 PN 63 Form B1 EN1092 shown on this MSG as D 0 0 _ DN 80 PN 63 Form B1 EN1092 valid, certain antennas may E 0 0 _ DN 100 PN 63 Form B1 EN1092 need to be mounted via the F 0 0 _ DN 40 PN 63 / PN 100 Form B1 EN1092 inside of the vessel if the L 0 0 _ DN 50 PN 100 Form B1 EN1092 opening in the tank is not of M 0 0 _ DN 80 PN 100 Form B1 EN1092 a sufficient diameter. N 0 0 _ DN 100 PN 100 Form B1 EN1092 (distance piece included) P 0 0 _ DN 150 PN 63 Form B1 EN1092 (distance piece included) R 0 0 _ DN 150 PN 100 Form B1 EN1092 (distance piece included) S 0 0 _ 1 1/2" NPT _ 1 1/2" 150 lb RF ASME B _ 1 1/2" 300 lb RF ASME B _ 2" 150 lb RF ASME B _ 2" 300 lb RF ASME B _ 3" 150 lb RF ASME B A 0 _ 3" 300 lb RF ASME B B 0 _ Be certain to confirm the 4" 150 lb RF ASME B C 0 _ size of the antenna to the 4" 300 lb RF ASME B D 0 _ size of the tank opening. 6" 150 lb RF ASME B E 0 _ While it is possible to use 8" 150 lb RF ASME B F 0 _ all of the combinations 6" 300 lb RF ASME B16.5 (distance piece included) 0 G 0 _ shown on this MSG as 1" 1/2 600 lb RF ASME B N 0 _ valid, certain antennas may 2" 600 lb RF ASME B P 0 _ need to be mounted via the 3" 600 lb RF ASME B16.5 (distance piece included) 0 R 0 _ inside of the vessel if the 4" 600 lb RF ASME B16.5 (distance piece included) 0 S 0 _ opening in the tank is not of 1.5" 900 lb / 1500 lb RF ASME B16.5 (distance piece included) 0 U 0 _ a sufficient diameter. 2" 900 lb / 1500 lb RF ASME B16.5 (distance piece included) 0 V 0 _ 3" 900 lb RF ASME B16.5 (distance piece included) 0 W 0 _ 4" 900 lb RF ASME B16.5 (distance piece included) 0 X 0 _ 10K 40A RF JIS B _ 10K 50A RF JIS B _ 10K 80A RF JIS B _ 10K 100A RF JIS B _ Bio Control DN C _ Tri-Clamp 2" 0 0 F _ DIN DN L _ SMS P _ 1 Output 4 20mA (Hart) _ 0 2 Outputs 4 20mA (Hart) mA _ 2 Foundation Fieldbus (4 wire + local HART) _ A Profibus PA (4 wire + local HART) _ D
3 TABLE Housing/Cable Entry/Cable gland Housing Option HMI (display & keys) Version No Selection TABLE V Calibration Certificates Construction Drawing / Tag Number 36-RM-16U-01 Page 3 of 5 Aluminum / M20 x 1.5 / without 0 Aluminum / 1/2" NPT / without 1 Aluminum / G 1/2" / without 2 Aluminum / M20 x 1.5 / Plastic (Non-Ex: black, Ex i: blue) 3 Aluminum / M20 x 1.5 / Metal (only for Ex d devices) 4 Stainless Steel / M25 x 1.5 / without A Stainless Steel / 1/2" NPT / without B Stainless Steel / M25 x 1.5 / plastic M20 (Non-Ex: Black, Exi blue) D Stainless Steel / M25 x 1.5 / metal M20 (only for Ex d devices) E _ 0 _ Weather Protection Option _ 2 _ - No Display 0 English 1 German 2 French 3 Italian 4 Spanish 5 Portugese 6 Japanese 7 Chinese (Mandarin) 8 Russian A Honeywell _ V _ Calibration certificate 2 points Calibration certificate 5 points (min. distance of 1.3 m (4.26 ft.)) Without NACE MR 0175 / MR 0103 _ 3 _ 0 Tag No. stainless steel plate (1 line; 12 characters) 2
4 Page 4 of 5 RESTRICTIONS Restrictions Available only with Not Available with Letter Table Selection Table Selection a 4, E b I _ A, _ D 3, B, D c I _, _, _, _, _, 0 A 0_, 0 B 0 _, 0 C 0 _, 0 D 0 _, 0 E 0 _, 0 F 0 _, _, _, _, _, _ 0, _ 2 U, V, W, X 2, 4, A, B, D, E d I _, _, _, _, _, 0 A 0_, 0 B 0 _, 0 C 0 _, 0 D 0 _, 0 E 0 _, 0 F 0 _, _, _, _, _, _ 0, _ 2 U, V, W, X e f I 2, 3, A, B, D, E _ A, _ D 4, B, E H, P, S, 2, 3, 5, A, B, C, H, K, I 0 0 C _, 0 0 F _, 0 0 L _, 0 0 P _, 6, 7, 8, G, H, P, S, _ P _, _ R _, _ S _, _ T _, A, B, C g I _, _, _, _, A 0 0 _, B 0 0 _, C 0 0 _, _, _, _, _, 0 A 0 _, 0 B 0 _, 0 C 0 _, 0 D 0 _, 0 E 0 _, 0 F 0 _, 0 G 0 _,0 0 5 _, _, _, _, 0 0 C _, 0 0 F _, 0 0 L _, 0 0 P _ 6, 7, 8, G, H, P, S, A, B, C h I _, _, _, _, A 0 0 _, B 0 0 _, C 0 0 _, _, _, _, _, 0 A 0 _, 0 B 0 _, 0 C 0 _, 0 D 0 _, 0 E 0 _, 0 F 0 _, 0 G 0 _, _, _, _, _, 0 0 C _, 0 0 F _, 0 0 L _, 0 0 P P _, _ R _, _ S _, _ T _ k A, B, C, X, Y I 0 0 C _, 0 0 F _, 0 0 L _, 0 0 P _
5 Page 5 of 5 I 0 0 C _, 0 0 F _, 0 0 L _, 0 0 P _ m I, _ 1 _, _ 2 _, _ 3 _, _ 4 _, _ 5 _, _ S _, _ T _ _, _, _, A 0 0 _, B 0 0 _, C 0 0 _, 0 A 0 _, _, 0 B 0 _, 0 C 0 _, 0 D 0 _, 0 E 0 _, 0 F 0 _, 0 G 0 _, _, _, _ 1 _, _ 2 _, _ 3 _, _ 4 _, _ 5 _, _ P _, _ R _ n I _, _, _, A 0 0 _, B 0 0 _, C 0 0 _, _, 0 A 0 _, 0 B 0 _, 0 C 0 _, 0 D 0 _, 0 E 0 _, 0 F 0 _, 0 G 0 _, _, _ o I _, _, A 0 0 _, 0 A 0 _, 0 B 0 _, 0 C 0 _, 0 D 0 _, _, _ p I B 0 0 _, C 0 0 _, 0 E 0 _, 0 F 0 _, 0 G 0 _ q r I I 0 0 F _, 0 0 L _ 0 0 C _ s 0 _ P, 0 _ S t 0 _ P, 0 _ S
Reflex-Radar BM 100 A
KROHNE 09/2001 7.02317.22.00 GR/PRINTO Reflex-Radar The universal TDR level gauge for liquids, solids and interface Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters
More informationED 701 General Industry Pressure Transmitter
ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationCertificate No.: IECEx BVS , issue 3 Annex Page 1 of 9
Page 1 of 9 General product information: The Radar-Sensor type VEGAPULS PS6*(*).******** and type VEGAPULS PSSR68(*).******** is used to measure the distance between the surface of combustible dust generating
More informationPressure Transmitter ED 701
Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation
More informationFluid Cooling Industrial PF Series
Fluid Cooling Industrial PF Series 0916 STAINLESS STEEL PLATES CARBON STEEL FRAME Performance Notes Carry bar Gasketed plate style heat exchanger Tie rods Oil to water applications High performance Pressure
More informationCoriolisMaster FCB430, FCB450, FCH430, FCH450 Coriolis mass flowmeter
Data Sheet DS/FCB400/FCH400-EN Rev. D CoriolisMaster FCB430, FCB450, FCH430, FCH450 Coriolis mass flowmeter High precision measurement of mass and volume flow, density, temperature and concentration with
More informationCoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis mass flowmeter
Data Sheet DS/FCB100/FCH100-EN Rev. D CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis mass flowmeter High precision measurement of mass and volume flow, density, temperature and concentration with
More informationDMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm
DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up
More informationConductivity sensor for hygienic applications
Conductivity sensor for hygienic applications Type 8221 can be combined with Perfect for demanding applications in the hygienic industry (CIP and SIP compatible) Variants available for usage over a wide
More informationTecnología en Electrónica y Control SRL Ficha Técnica
Tecnología en Electrónica y Control SRL Ficha Técnica Caudalímetros Tecnología en Electrónica y Control SRL Oficina Central Wüthrich 949 San Carlos Centro (S3013DES) / Santa Fe / Argentina Tel./Fax/Líneas
More informationTarget Insertion Flowmeter
Principle of Operation Flow is measured in terms of dynamic force acting on a target (solid disk) in the flow stream. Hermetically sealed, bonded strain gages in a bridge circuit configuration mounted
More informationVA Master FAM540 Metal Cone Variable Area Flowmeter
Contents Data Sheet Rev. B VA Master FAM50 Metal Cone Variable Area Flowmeter For metering liquids, gases and steam Graphic, 2-line display Magnet stick operation Configuration also possible with closed
More informationVersaFlow Ultrasonic clamp-on Flowmeter Specifications
VersaFlow Ultrasonic clamp-on Flowmeter Specifications 34-VF-03-14 September 2009 Clamp-On Technology HONEYWELL S VersaFlow stands for continuity and long term reliability. Flow measurement can be done
More informationField IT 50T Series Transmitters
Data Sheet SS/G/A_ Field IT 0T Series Transmitters gauge/absolute pressure transmitter Ranges: -00 to 0000kPa - to 00bar -. to 6000psi Base accuracy : 0.% (BFSL) Chemical Vapour Deposition (CVD) technology
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationDMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationPressure Measurement Single-range transmitters for general applications
Siemens AG 07 Overview Function SITRANS LH00 Transmitter for hydrostatic level U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/
More informationPressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27
Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for
More informationTSK. Flap-Type Flowmeter. Range: to GPM Accuracy: ± 2.5% of Full Scale P max. : 580 PSI T max
Flap-Type Flowmeter measuring monitoring analyzing TSK Range: 6.6...26.4 to 880...6600 GPM Accuracy: ± 2.5% of Full Scale P max : 580 PSI T max : -40 572 F Connection: Wafer Flange 1.5" 20" ASME Material:,
More information1 Overview. Pressure Measurement Transmitters for applications with basic requirements (Basic) SITRANS P310 - Technical description
Siemens AG 207 SITRANS P0 - Technical description Overview SITRANS P0 pressure transmitters are digital pressure transmitters with a high level of operating convenience. With a measurement accuracy of
More informationPro-V Multivariable Flowmeter Model M23 Insertion Vortex
Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,
More informationDM70 Hand-Held Dewpoint Meter for Spot-Checking Applications
DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed
More informationDIFFERENTIAL PRESSURE (FLOW) TRANSMITTER
DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER DATA SHEET FKC...5 The FCX AIII differential pressure (flow) transmitter accurately measures differential pressure, liquid level, gauge pressure or flow rate and
More information2.12. Ex-Linear light fittings for fluorescent lamps. nllk W - 58 W (Zone 2, 21, 22)
.1 Ex-Linear light fittings for fluorescent lamps nllk 08 18 W - 58 W (Zone, 1, ) The lighting solution for hazardous areas in Zones, 1 and The linear luminaires series nllk 08 for fluorescent lamps combines
More informationDS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm
Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar
More informationPro-V Multivariable Flowmeter Model M23 Insertion Vortex
Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,
More informationATEX/IECEx RTD temperature probe
Page 1/8 ATEX/IECEx RTD temperature probe with connecting cable acc. to DIN EN 60751 For temperatures from -100 to +600 C As single, double, or triple RTD temperature probe In two-wire, three-wire, or
More informationDMHP3(4)L(T)2A00 Series
STANDARDS Valve body: ASME B16.34 Material certification: EN10204-3.1 MTR Quality assurance: ISO 9001:2008 Steel casting: MSS SP-55 Valve marking: MSS SP-25 Valve test: API 598 Direct mount: ISO 5211 End
More informationFull Metal Variable Area Flow Meter and Counter
Full Metal Variable rea Flow Meter and Counter for horizontal and vertical mounting measuring monitoring analysing Special versions up to 600 bar Measuring range: 10-100...00-000 L/h water 0.3-3.0...-0
More informationIBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationIBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationExchangeable measuring insets SensyTemp TSA101
Contents Data Sheet Exchangeable measuring insets SensyTemp TSA101 for resistance thermometers and thermocouples Structure of electrical thermometers - Exchangeability during operation based on modular
More informationPro-V Multivariable Flowmeter Model M22 In-line Vortex
Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,
More informationTransmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level
Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level
More informationISEmax CAM40/CAS40. Technical Information
Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works
More informationCertificate No.: IECEx BVS issue No. 1 Annex Page 1 of 8 Subject and Type
Certificate No.: IECEx BVS 12.0066 issue No. 1 Page 1 of 8 Subject and Type VEGAFLEX FX81(*). I * * ** * * * * * * * Certificates: X = no, M - yes adjustment / indication module PLICSCOM X = without: A
More informationTemperature sensors SensyTemp TSP311, TSP321, TSP331
Contents Data Sheet Temperature sensors SensyTemp TSP311, TSP321, TSP331 Modular system - Measuring inset, thermowell, extension tube, connection head, transmitter - Supports numerous configurations Exchangeable
More informationVersaFlow TWM 9000 Electromagnetic Flow Converter Technical Datasheet. Specification. Highlights. Electromagnetic product range.
VersaFlow TWM 9000 Electromagnetic Flow Converter Technical Datasheet 34-VF-03-02 June 1, 2007 Specification The high-performance solution The TWM 9000 is the only electromagnetic flow converter with diagnostics
More information98 Series Backpressure Regulators and Relief Valves
9 Series Backpressure Regulators and Relief Valves Bulletin.:9 November 09 W TYPE 9H W TYPE 9LD Figure. Typical 9 Relief Valves Introduction W TYPE 9HD The 9 Series (Figure ) is used for backpressure or
More information4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)
.2 Ex-Ceiling light fittings AB 8 / AB 5 LED / AB 5 / AB 12 NAV 7 (Zone 1, 2, 21, 22) The wall and ceiling light fixtures for particularly difficult operating conditions The impact-resistant and flameproof
More informationxce series & xjf EXPLOSIONPROOF ENCLOSURES EXPLOSIONPRROOF ENCLOSURES CERTIFICATIONS STANDARD FEATURES DESIGN OPTIONS MATERIAL ADALET.
EXPLOSIONPROOF XCE: Explosionproof Control Enclosures XCEX: Flameproof Control Enclosures XCEQ: Explosionproof Quad-Lead Control Enclosures XJF: Explosionproof Junction Boxes STANDARD FEATURES standard
More informationSMV 3000 Smart Multivariable Flow Transmitter Specifications
SMV 3000 Smart Multivariable Flow Transmitter Specifications 34-SM-03-01 August 2010 Introduction The SMV 3000 combines integrated sensor and microprocessor technologies as well as dynamic flow compensation
More informationSITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181
Siemens AG 09 SITRANS F flowmeters System information Overview Siemens offers two types of ultrasonic flowmeters, in-line flowmeters and clamp-on flowmeters. This offers the end user the maximum flexibility
More informationGeneral Specifications
General Specifications GS 01C31D01-01EN EJA310E EJA310E 4~0 ma DC EJA-E BRAINHART/HART(1~5VDC ) FFPROFIBUS PA, SIL FFGS 01C31T0-01CN PROFIBUS PAGS 01C31T04-01CN kpa abs psi abs (/D1) 0.67~10 0. ~.95 inhg
More informationSwitches in conformity with ATEX directive
E Switches in conformity with ATEX directive page / General Catalog 09-0 Technical concepts page /9 A B Position switches FD series page / Category Zone Approvals Article code extension G M ATEX category
More informationMetal Cone Variable Area Flowmeter VA Master FAM540
Pos: 1 /Titelblätter / Copyright/DB/Durchfluss/FAM50 @ 21\mod_121363691921_3101.doc @ 20022 Pos: 2 /Inhaltsverzeichnis/Inhaltsverzeichnis für alle Dokumente @ 0\mod_11371031090_3101.doc @ 3129 Contents
More informationThe 505F Series 3/4/5-Way Ball Valve. Standard Features and Benefits. Operating Conditions. Specifications. Options
The 505F Series //5-Way Ball Valve The 505F is a true multi-way ball valve with balanced fourseat construction. This full port valve is available in a variety of flow plans which can replace multiple two-way
More informationA BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET. SensyTemp TSA101 Exchangeable measuring insets
A BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET SensyTemp TSA101 Exchangeable measuring insets 2 SENSYTEMP TSA101 EXCHANGEABLE MEASURING INSETS DS/TSA101-EN REV. E Measurement made easy Compatible
More informationISEmax CAS40D. Technical Information
Technical Information ISEmax CAS40D Online measurement of nutrient parameters Ion-selective electrodes for the continuous measurement of ammonium, nitrate and other ions Application The ion-selective sensor
More informationZ7A. Load cells. Special features. Data sheet. Wiring code
Z7A Load cells Special features - Complies with OIML R60 regulations up to 3000 d - Max. capacities: 500 kg... 10 t - Fulfills EMC requirements in accordance to EN 45 501 - Low transducer height - Robust
More information4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure
.13 Ex-Floodlights of the series / (Zone 2, 22) The powerful LED floodlights FMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all general lighting applications in
More information4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22)
.3 Ex-Pendant light fittings AB 5 / SPG 1N / AB 51 / EVI 2 / EVI 5 / EV35 LED (Zone 1, 2, 21, 2 The pendant light fitting series for a wide variety of applications The explosion-protected pendant light
More informationVersaFlow TWM 9000 Electromagnetic Flow Converter Technical Datasheet. Specification. Highlights. Electromagnetic product range.
VersaFlow TWM 9000 Electromagnetic Flow Converter Technical Datasheet September, 2009 Specification The high-performance solution The TWM 9000 is the only electromagnetic flow converter with diagnostics
More informationSTT 3000 Temperature Probe Assemblies Series STT830 - Threaded & Socket Weld Thermowell Assembly with Transmitter Option
Page: STT-27 STT 3000 Temerature Proe Assemlies Series STT830 - Threaded & Socket Weld Thermowell Assemly with Transmitter Otion Model Selection Guide 34-44-16-09 Issue 25 Model Selection Guide Honeywell
More informationCV3000 Series. Characterized Insert Control Valves
CV3000 Series Characterized Insert Control Valves The CV3000 Series is a v-type control valve for precise control allowing high pressure drop capability with straight-through flow and bubble-tight shut
More informationEX-EMERGENCY LIGHT FITTINGS
EX-EMERGENCY LIGHT FITTINGS nllk 0...N 1-36 W Plastic version for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 N are conform to the requirements of the ATEX-Directive
More informationFKC... 5 DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER FEATURES SPECIFICATIONS. Functional specifications
FKC... 5 DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER The FCX AIII differential pressure (flow) transmitter accurately measures differential pressure, liquid level, gauge pressure or flow rate and transmits
More informationGC005 thru GC600. Wireless Load Cell. Features. Applications. General Description. Load Cell
Wireless Load Cell Features Standard single part line pull sizes ranging from 5,000 to 600,000 lb. All stainless frame and hardware Heavy duty construction from 17-4PH1150 stainless steel (17-4PH1025 on
More informationv = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes
Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes Examples of Application Flow measurements also in hazardous locations X zone 0 or zone 1 in clean rooms in air
More informationGlobe Valve, Metal. Sectional drawing. *see information on working medium on page 2
Globe Valve, Metal Construction The GEMÜ pneumatically operated /-way valve has a robust low maintenance aluminium actuator. The valve spindle is sealed by a self-adjusting gland packing providing low
More informationIN-FLOW Industrial Style Digital Mass Flow Meters and Controllers for Gases
IN-FLOW Industrial Style Digital Mass Flow Meters and Controllers for Gases > Introduction Bronkhorst High-Tech B.V., the European market leader in low flow thermal and Coriolis Mass Flow Meters/Controllers,
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. PGC5000 Temperature programmed gas chromatograph
ABB MEASUREMENT & ANALYTICS DATA SHEET PGC5000 Temperature programmed gas chromatograph 2 P G C 5 0 0 0 T E M P E R AT U R E P R O G R A M M E D D S/ P G C 5 0 0 0 T P - E N Measurement & Analytics The
More informationVersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009
VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet 34-VF-03-14 September 2009 Specification Clamp-on technology HONEYWELL S VERSAFLOW stands for continuity and long term reliability. Flow measurement
More informationTF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels
TF 0 / TF 0-Ex Field mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.69 EN USA Input Resistance thermometer (,, wire circuit) Thermocouples
More informationIts modular concept allows to build up a ball valve for any degree of automation and any kind of application
Type 2657...59 DN 10 up to 80 mm; Plastic; 2/2 way dvantages/benefits ntegrated pilot valves, position feed-back and limit switches available Customized system solutions with Burkert valves & sensors With
More informationSMV 3000 Smart Multivariable Flow Transmitter
SMV 3000 Smart Multivariable Flow Transmitter Measurements and Calculations: Differential Pressure Absolute or Gauge Pressure Process Temperature via 100 ohm Pt. RTD or Type J,K,T or E Thermocouple Mass
More informationType M4 - SON - SO - MS
9. REV. Type M - SON - SO - MS Aircaps Tank venting and water excluding aircaps. For installation on service tank air pipes. Inerted void spaces and ballast tanks In order to maintain inert gas pressure
More informationVDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems
06 EN - Straight valves VDN.. Angle valves VEN.. Reverse angle valves VUN.. ACVATIX TM Radiator valves NF norm, for -pipe heating systems VDN.. VEN.. VUN.. Valve bodies made of brass, mat nickel-plated
More informationVortex Flow Measuring System PROline prowirl 72
Technical Information TI 062D/06/en No. 50103356 Vortex Flow Measuring System PROline prowirl 72 Reliable Flow Measurement of Gas, Steam and Liquids Application For measuring the volume flow of steam,
More informationEx-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments
.13 Ex-Floodlights of the series / / (Zone 2, 21, 22) The powerful LED floodlights FMV/nFMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all ge neral lighting applications
More informationE X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S
E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S EX- CONTROL UNITS AND CONTROL STATIONS EX- INSTALLATION SWITCH.. EX- CONTROL STATIONS INDIVIDUAL EX- CONTROL STATIONS.. 0 EX- CONTROL AND
More informationTF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.
TF / TF -Ex Field mounted temperature transmitters, PROFIBUS PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN P R O F I PROCESS FIELD BUS B U S Input Resistance thermometer (,, -wire
More informationLevel Sensor PanCake PR 6251 and Mounting Kit PR 6051
Level Sensor PanCake PR 6251 and Mounting Kit PR 6051 The space-saving solution for simple applications The sensors of the PR 6251 series have been specially designed for simple weighing of silos and horizontal
More informationLEVEL CONTROLS. Selection Guide. Capacitance Calculations and Data For Selecting Robertshaw Level Control Instruments and Sensing Probes
LEVEL CONTROLS Selection Guide Capacitance Calculations and Data For Selecting Robertshaw Level Control Instruments and Sensing Probes Capacitance Probe Calculations The following data is compiled to assist
More informationDS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.
DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link
More informationTF 212 / TF 212-Ex. Field mounted temperature transmitter, Profibus PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels. ABB Instrumentation
TF / TF -Ex Field mounted temperature transmitter, Profibus PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN According to PROCESS FIELD BUS 0Input Resistance thermometer (,, -wire method)
More informationPermanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate
Technical specification FLUXUS F502TE Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate Stationary ultrasonic clamp-on system for
More informationEx floating switches and Ex immersion probes
Ex floating switches and Ex immersion probes Controlling devices with ball-operated microswitch, for signalling or regulation of liquid levels Jola Spezialschalter GmbH & Co. KG Klostergartenstr. 11 67466
More informationDirect-operated 2/2-way compact solenoid valves Type EV210A
Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together
More information/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2
/ way valves (solenoid actuated diaphragm with forced lifting) /4... Damped operation Operation without differential Suitable for vacuum igh flow rate For systems with low or fluctuating Brass body Wide
More information507F. Multi-Port Sanitary Ball Valve. Full Port ISO 5211 Mounting Pad. For Automated & Manual Service. Pharmaceutical. Bio-Technology.
507F Multi- Sanitary Ball Valve Full ISO 5 Mounting Pad For Automated & Manual Service Pharmaceutical Bio-Technology Cosmetic Food & Beverage The 507F Series //5-Way Sanitary Ball Valve The 507F is a true
More informationVARIABLE AREA FLOWMETERS
F-00N F-0N F-00N BENEFITS Tugh machined acrylic meter bdy, highly plished t a clear finish. White back reflectr fr easy reading. Sturdy adapters with high grade Vitn -ring seals. Standard mdels # stainless
More informationSECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:
SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine
More informationIndustrial Resistance Thermometers according to DIN Model MWD
Industrial Resistance Thermometers according to DIN measuring monitoring analysing MWD OMeasuring O range: -98... +600 ºC O O Pt00 sensor: class A, class B, class /3, class /0, or O O Output: resistance
More informationI nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I
I nllk / I x W x W x W x W x W Technical data Cooper Crouse-Hinds - all rights reserved nllk / nllk nllk / nllk nllk / Marking to //EC II G Ex na II T / II D td A IP T C EC Conformity Statement PTB ATEX
More informationSINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol
SINEAX VK 66 for RTD and TC inputs, with HART procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application II () G SINEAX VK 66 is a two-wire head-mounted transmitter.
More information2.9. Namur Valves 2.9. page 175. Namur 1/4 also called Namur 1 in accordance to VDI / VDE Namur 1/2 also called Namur 2.
2.9 page 175 Namur 1/4 also called Namur 1 in accordance to VDI / VDE 3845. Namur 1/2 also called Namur 2. 2.9 Namur Valves + Selected models are available for low temperature application. Temperature-range:
More informationAmphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme
Amphenol Amphenol-Tuchel Electronics GmbH Series C 146 Heavy Duty Connectors Core Programme The Company General information These connectors are designed and produced in conformity with the voltage directive
More informationSolenoid valves 2/2-way direct-operated type EV210A
MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valves 2/2-way direct-operated type EV210A EV210A covers a wide range of small, direct-operated 2/2-way solenoid valves for use in industrial machinery.
More informationKOTRON RF SENSING PROBES. Worldwide level and flow solutions
KOTRON RF SENSING PROBES Kotron RF Capacitance sensing probes are available in many different configurations to handle a wide variety of application conditions. The sensing probes in this brochure can
More informationPneumatic Universal. Actuator MOTORIZED VALVES USE TECHNICAL FEATURES OF THE ACTUATOR. Data sheet
Data sheet. - 8 USE The motorized valve is specifically used for the interception and regulation of fluids in: systems using alternative energy industrial systems in general using hot and cold fluids automation
More informationSurface-mounting Thermostats ATH Type Series
Page 1/9 urface-mounting Thermostats ATH eries k enclosure protection IP 54 k tested to IN EN 14597 (replacing IN 3440) Brief description Thermostats control and monitor thermal processes. Instruments
More informationTPH. 60Hz. Standard mode TPH 4T 2K. Code TPH 4T 2K S F A H
C US NSF/ANSI TPH Applications: The TPH Series are modernly designed with quiet and high efficient operation pumps, suitable for dependable water transfer, circulating or booster service. -Industrial circulation
More informationSurface-mounting thermostats Series ATH
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
More informationExplosion-protected recessed ceiling LED-light and fluorescent light fittings
.7 Explosion-protected recessed ceiling LED-light and fluorescent light fittings LED 600, RLF LED 100 and self-contained emergency luminaire RLF LED 600 N, RLF LED 100 N RLF/RLF-INOX 50 18-58 W / RLF/RLF-INOX
More informationKOTRON RF SENSING PROBES. Worldwide level and flow solutions FEATURES AGENCY APPROVALS APPLICATIONS. A probe to satisfy each application
KOTRON RF SENSING PROBES Kotron RF Capacitance sensing probes are available in many different configurations to handle a wide variety of application conditions. The sensing probes in this brochure can
More informationType UB1 Load Cell. Option Stainless steel cable gland
Type UB1 Load Cell IP68 APPROVED Product Description Type UB1 is a stainless steel universal load cell which allows for tension and compression loading. Its complete hermetic sealing makes it suitable
More informationDM70 Hand-Held Dewpoint Meter for Spot-Checking Applications
DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed
More informationApplication PN 16 / 40 DN Product features. Compact overall height Body shape gives optimum flow characteristic
pplication Control of gases, vapours and liquids. The modular concept of valve, multi spring actuator and digital FOXBORO/Eckardt positioner Type SRD 992 facililates trouble free expansion to allow for
More information