Industrial Resistance Thermometers according to DIN Model MWD

Size: px
Start display at page:

Download "Industrial Resistance Thermometers according to DIN Model MWD"

Transcription

1 Industrial Resistance Thermometers according to DIN measuring monitoring analysing MWD OMeasuring O range: ºC O O Pt00 sensor: class A, class B, class /3, class /0, or O O Output: resistance or analogue ma O O Option: head with HART -protocol or Profibus /Fieldbus, display OProtection O / measuring insert material: steel.4404, others on request T2 /2-208 KOBOLD companies worldwide: AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHINA, CZECHIA, EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, Republic of Korea, ROMANIA, SPAIN, SWITZERLAND, THAILAND, TUNISIA, turkey, USA, VIETNAM KOBOLD Messring GmbH Nordring D-6579 Hofheim/Ts. Office: +49(0) (0) info.de@kobold.com

2 Description KOBOLD temperature assemblies comprise a rugged installation fitting made of steel with thread, flange or weld-on process, a head and a measuring element. A Pt00 temperature sensor according to IEC 75, class A, B, / 3 DIN or / 0 is fitted in the measuring element. On request, the measuring element can be removable, thus, allowing to remove the measuring element without interrupting the process as the customised thermowell remains in the installation and seals the process. Alternatively these sensors can be designed as single or double resistance thermometers, except the 4-wire version, which can only be built with one Pt00 due to lack of space. As an option the resistance thermometers can be supplied with a head. Transmitter with a standard 4-20 ma signal, with HART protocol or with Profibus /Fieldbus are there to choose from. Transmitter Resistance thermometers with head are used whenever a measuring signal must be transported long distance without any disturbance. The head which is encapsulated in epoxies resin is located right in the head and delivers a temperature-linear output signal of 4-20 ma. The head is available with standardised communication systems just like HART protocol or Profibus /Fieldbus. Applications OO HVAC OO Machinery OOChemical and petrochemical industries OOHeating /cooling processes OOIndustrial uses in general The resistance thermometers with thread and flange are favourably used for the temperature measurement in liquids, solids and gaseous media. The reliable water tightness of these installation methods for gauge pressure and vacuum is an important criteria for selection. Technical Details Measuring principle: temperature depending resistor Measuring range: C ºC ºC ºC Sensor: Pt00 single or double sensor ( x Pt00 or 2 x Pt00) IEC 75 Accuracy: class A, class B, /3 DIN, /0 DIN Ambient temperature: C with ceramic terminal block (without ) C (with ) C (with LCD display) C (with LED display) Connection head: BR screwed cover, with chain, DIN B cover with two screws, BUZ, hinged cover BUZ-H, high model hinged cover and others Electrical : M20 x.5 standard (others on request) Materials: Sensor: steel.4404 Connection head:, painted, steel, and PP (others on request) Terminal block: ceramic (without ) : Thread: G ¼, G ½, G ¾, G male, ¼" NPT, ½" NPT, ¾" NPT, " NPT male DIN-flange: DN 5, 20, 25, 32, 40, 50 PN 0, 6, 40 ANSI flange: ½", ¾", ", ½", 2" class 50, class 300 Max. pressure: Sensor wiring: Output: 30 bar 2, 3 or 4-wire resistance value Protection: head IP depending on cable gland Measuring insert exchangeable Protection / P max MWD-C, E, D yes yes / 30 bar MWD-F, G, W ) yes no / P atm MWD-A, B, L no yes / 30 bar ) F/G/W only with thermowell TWL-0 2 /2-208

3 EL MWD-A compact compression fitting Sensor element: Pt 00 3-wire class B, A, /3, /0,, and others Electrical : M20x.5 Max. pressure: 30 bar (at 20 C) Protective : according to DIN 43772, filled with magnesium oxide (MgO) steel.4404 (36L) D /2-208 MWD-A Protective diameter (D) 4 = Ø4 9 = Ø9 A = Ø0 C = Ø2 000 = none K5 = compression fitting G½-M C5 = compression fitting ½" NPT-M XX A = x Pt 00 class B B = 2 x Pt 00 class B C = x Pt 00 class A D = 2 x Pt 00 class A E = x Pt 00 class B F = 2 x Pt 00 class B G = x Pt 00 class A H = 2 x Pt 00 class A I = x Pt 00 class B J = 2 x Pt 00 class B K = x Pt 00 class A L = 2 x Pt 00 class A M = x Pt 00 class /3 DIN (-70 N = x Pt 00 class / 0 DIN (-70 O = x Pt 00 class / 3 DIN (-70 P = x Pt 00 class / 0 DIN (-70 RTD wiring 2 = 4 3) = 4-wire Terminal head G = screw-cap with I = screw-cap with chain, steel.440 P = screw-cap with chain, PP M ) = mini head screw-cap with K = head screwcap, steel.440 B = DIN B screwed cover, Z = BUZ hinged cover, H = BUZ-H high model with hinged cover, E ) = head with LCD display and HART included D = with LCD display, steel.430 R = as D + 2 relay Q = x Pt 00 class ( ºC) ) Only without 2) Please specify the measuring range in clear text, while ordering 3) With x Pt00 only 4) For A, B, C, D choose RTD wiring code»3«note: Please specify length»el«in clear text, while ordering 4), only with ceramic terminal A 2) = 5333D B 2) = 5337D with HART protocol C 2) = 5350A Profibus / Fieldbus D = prepared for subsequent mounting of Y = acc. to 3

4 EL MWD-L compact fixed thread Sensor element: Pt00 3-wire class B, A, /3, /0,, and others Electrical : M20x.5 Max. pressure: 30 bar (at 20 C) Protective : according to DIN 43772, filled with magnesium oxide (MgO) steel.4404 (36L) D MWD-L Protective diameter (D) 3 = Ø3 4 = Ø4 9 = Ø9 A = Ø0 C = Ø2 G08 = G ¼-M G5 = G ½-M G20 = G ¾-M G25 = G-M N08 = ¼" NPT-M N5 = ½" NPT-M N20 = ¾" NPT-M N25 = " NPT-M XX A = x Pt00 class B B = 2 x Pt00 class B C = x Pt00 class A D = 2 x Pt00 class A E = x Pt00 class B F = 2 x Pt00 class B G = x Pt00 class A H = 2 x Pt00 class A I = x Pt00 class B J = 2 x Pt00 class B K = x Pt00 class A L = 2 x Pt00 class A M = x Pt00 class /3 DIN (-70 N = x Pt00 class / 0 DIN (-70 O = x Pt00 class / 3 DIN (-70 P = x Pt00 class / 0 DIN (-70 RTD wiring 2 = 4 3) = 4-wire Q = x Pt00 class ( ºC) ) 2) Only without Please specify the measuring range in clear text, while ordering 3) 4) With x Pt00 only For A, B, C, D choose RTD wiring code '3' Terminal head G = screw-cap with I = screw-cap with chain, steel.440 P = screw-cap with chain, PP M ) = mini head screw-cap with K = head screwcap, steel.440 B = DIN B screwed cover, Z = BUZ hinged cover, H = BUZ-H high model with hinged cover, E ) = head with LCD display and HART included D = with LCD display, steel.430 R = as D + 2 relay 4), only with ceramic terminal A 2) = 5333D B 2) = 5337D with HART protocol C 2) = 5350A Profibus / Fieldbus D = prepared for subsequent mounting of Y = acc. to Note: Please specify length 'EL' in clear text, while ordering 4 /2-208

5 HL=30 EL 2 ø0 HL=30 EL ø0 MWD-B compact threaded or flanged with neck pipe Sensor element: Pt00 3-wire class B, A, /3, /0,, and others Neck pipe HL: 30 mm Electrical : M20x.5 Max. pressure: 30 bar (at 20 C) Protective : according to DIN 43772, filled with magnesium oxide (MgO) steel.4404 (36L) D D /2-208 Protective diameter (D) G08 = G ¼-M G5 = G ½-M G20 = G ¾-M G25 = G -M N08 = ¼" NPT-M N5 = ½" NPT-M N20 = ¾" NPT-M N25 = " NPT-M F5 = DN5 PN6 F20 = DN20 PN6 F25 = DN25 PN6 F32 = DN32 PN6 MWD-B 4 = Ø4 9 = Ø9 A = Ø0 C = Ø2 F40 = DN40 PN6 F50 = DN50 PN6 H5 = DN5 PN40 H20 = DN20 PN40 H25 = DN25 PN40 H32 = DN32 PN40 H40 = DN40 PN40 H50 = DN50 PN40 A5 = ½"CL50 RF A20 = ¾" CL50 RF A25 = " CL50 RF A40 = ½" CL50 RF A50 = 2" CL50 RF B5 = ½" CL300 RF B20 = ¾" CL300 RF B25 = " CL300 RF B40 = ½" CL300 RF B50 = 2" CL300 RF XX A = x Pt00 class B B = 2 x Pt00 class B C = x Pt00 class A D = 2 x Pt00 class A E = x Pt00 class B F = 2 x Pt00 class B G = x Pt00 class A H = 2 x Pt00 class A I = x Pt00 class B J = 2 x Pt00 class B K = x Pt00 class A L = 2 x Pt00 class A M = x Pt00 class /3 DIN (-70 N = x Pt00 class / 0 DIN O = x Pt00 class / 3 DIN (-70 P = x Pt00 class / 0 DIN Q = x Pt00 class ( ºC) RTD wiring 2 = 4 3) = 4-wire Terminal head G = screw-cap with I = screw-cap with chain, steel.440 P = screw-cap with chain, PP M ) = mini head screw-cap with K = head screwcap, steel.440 B = DIN B screwed cover, Z = BUZ hinged cover, H = BUZ-H high model with hinged cover, E ) = head with LCD display and HART included D = with LCD display, steel.430 R = as D + 2 relay 4), only with ceramic terminal A 2) = 5333D B 2) = 5337D with HART protocol C 2) = 5350A Profibus / Fieldbus D = prepared for subsequent mounting of ) Only without 2) Please specify the measuring range in clear text, while ordering 3) With x Pt00 only 4) For A, B, C, D choose RTD wiring code '3' Note: Please specify length 'EL' in clear text, while ordering Y = acc. to 5

6 EL MWD-C compact with removable measuring insert Sensor element: Pt00 3-wire class B, A, /3, /0,, and others Electrical : M20x.5 Max. pressure: 30 bar (at 20 C) Protective : according to DIN steel.4404 (36L) Measuring insert: filled with magnesium oxide (MgO) D MWD-C Protective diameter (D) 9 = Ø9 A = Ø0 C = Ø2 G08 = G ¼-M G5 = G ½-M G20 = G ¾-M G25 = G-M N08 = ¼" NPT-M N5 = ½" NPT-M N20 = ¾" NPT-M N25 = " NPT-M XX A = x Pt00 class B B = 2 x Pt00 class B C = x Pt00 class A D = 2 x Pt00 class A E = x Pt00 class B F = 2 x Pt00 class B G = x Pt00 class A H = 2 x Pt00 class A I = x Pt00 class B J = 2 x Pt00 class B K = x Pt00 class A L = 2 x Pt00 class A M = x Pt00 class /3 DIN (-70 N = x Pt00 class / 0 DIN (-70 O = x Pt00 class / 3 DIN (-70 P = x Pt00 class / 0 DIN (-70 Q = x Pt00 class ( ºC) RTD wiring 2 = 4 3) = 4-wire ) 2) Only without Please specify the measuring range in clear text, while ordering 3) 4) With x Pt00 only For A, B, C, D choose RTD wiring code '3' Note: Please specify length 'EL' in clear text, while ordering 6 Terminal head G = screw-cap with I = screw-cap with chain, steel.440 P = screw-cap with chain, PP M ) = mini head screw-cap with K = head screwcap, steel.440 B = DIN B screwed cover, Z = BUZ hinged cover, H = BUZ-H high model with hinged cover, E ) = head with LCD display and HART included D = with LCD display, steel.430 R = as D + 2 relay 4), only with ceramic terminal A 2) = 5333D B 2) = 5337D with HART protocol C 2) = 5350A Profibus / Fieldbus D = prepared for subsequent mounting of Y = acc. to /2-208

7 EL MWD-E compact with removable measuring insert and compressing fitting Sensor element: Pt00 3-wire class B, A, /3, /0,, and others Electrical : M20x.5 Max. pressure: 30 bar (at 20 C) Protective : according to DIN steel.4404 (36L) Measuring insert: filled with magnesium oxide (MgO) D MWD-E Protective diameter (D) 9 = Ø9 A = Ø0 C = Ø2 000 = none K5 = compression fitting G½-M C5 = compression fitting ½" NPT-M XX A = x Pt00 class B B = 2 x Pt00 class B C = x Pt00 class A D = 2 x Pt00 class A E = x Pt00 class B F = 2 x Pt00 class B G = x Pt00 class A H = 2 x Pt00 class A I = x Pt00 class B J = 2 x Pt00 class B K = x Pt00 class A L = 2 x Pt00 class A M = x Pt00 class /3 DIN (-70 N = x Pt00 class /0 DIN (-70 O = x Pt00 class /3 DIN (-70 P = x Pt00 class /0 DIN (-70 Q = x Pt00 class ( ºC) RTD wiring 2 = 4 3) = 4-wire Terminal head G = screw-cap with I = screw-cap with chain, steel.440 P = screw-cap with chain, PP M ) = mini head screw-cap with K = head screw-cap, steel.440 B = DIN B screwed cover, Z = BUZ hinged cover, H = BUZ-H high model with hinged cover, E ) = head with LCD display and HART included D = with LCD display, steel.430 R = as D + 2 relay 4), only with ceramic terminal A 2) = 5333D B 2) = 5337D with HART protocol C 2) = 5350A Profibus / Fieldbus D = prepared for subsequent mounting of Y = acc. to /2-208 ) 2) 3) Only without Please specify the measuring range in clear text, while ordering With x Pt00 only 4) For A, B, C, D choose RTD wiring code '3' Note: Please specify length 'EL' in clear text, while ordering 7

8 HL=30 EL 2 ø0 HL=30 EL ø0 MWD-D compact with removable measuring insert and extension neck pipe Sensor element: Pt00 3-wire class B, A, /3, /0,, and others Neck pipe HL: 30 mm Electrical : M20x.5 Max. pressure: 30 bar (at 20 C) Protective : according to DIN steel.4404 (36L) Measuring insert: filled with magnesium oxide (MgO) D D MWD-D Protective diameter (D) 9 = Ø9 A = Ø0 C = Ø2 G08 = G ¼-M G5 = G ½-M G20 = G ¾-M G25 = G -M N08 = ¼" NPT-M N5 = ½" NPT-M N20 = ¾" NPT-M N25 = " NPT-M F5 = DN5 PN6 F20 = DN20 PN6 F25 = DN25 PN6 F32 = DN32 PN6 F40 = DN40 PN6 F50 = DN50 PN6 H5 = DN5 PN40 H20 = DN20 PN40 H25 = DN25 PN40 H32 = DN32 PN40 H40 = DN40 PN40 H50 = DN50 PN40 A5 = ½" CL50 RF A20 = ¾" CL50 RF A25 = " CL50 RF A40 = ½" CL50 RF A50 = 2" CL50 RF B5 = ½" CL300 RF B20 = ¾" CL300 RF B25 = " CL 300 RF B40 = ½" CL 300 RF B50 = 2" CL 300RF XX A = x Pt00 class B B = 2 x Pt00 class B C = x Pt00 class A D = 2 x Pt00 class A E = x Pt00 class B F = 2 x Pt00 class B G = x Pt00 class A H = 2 x Pt00 class A I = x Pt00 class B J = 2 x Pt00 class B K = x Pt00 class A L = 2 x Pt00 class A M = x Pt00 class /3 DIN (-70 N = x Pt00 class / 0 DIN O = x Pt00 class / 3 DIN (-70 P = x Pt00 class / 0 DIN Q = x Pt00 class ( ºC) RTD wiring 2 = 4 3) = 4-wire ) 2) Only without Please specify the measuring range in clear text, while ordering 3) 4) With x Pt00 only For A, B, C, D choose RTD wiring code '3' Note: Please specify length 'EL' in clear text, while ordering 8 Terminal head G = screw-cap with I = screw-cap with chain, steel.440 P = screw-cap with chain, PP M ) = mini head screw-cap with K = head screwcap, steel.440 B = DIN B screwed cover, Z = BUZ hinged cover, H = BUZ-H high model with hinged cover, E ) = head with LCD display and HART included D = with LCD display, steel.430 R = as D + 2 relay 4), only with ceramic terminal A 2) = 5333D B 2) = 5337D with HART protocol C 2) = 5350A Profibus / Fieldbus D = prepared for subsequent mounting of Y = acc. to /2-208

9 EL MWD-F compact fixed thread with removable measuring insert ), for mounting in thermowell Sensor element: Pt00 3-wire class B, A, /3, /0,, and others : threaded Electrical : M20x.5 Max. pressure: P atm only with thermowell TWL-0 Measuring insert: according to DIN 43772, filled with magnesium oxide (MgO) steel.4404 (36L) Dd Note: For order details of the thermowell see datasheet TWL-0. Without thermowell atmospheric pressure. ) Without protection /2-208 MWD-F Measuring insert diameter (d) 3 = Ø3 4 = Ø4 G08 = G ¼-M G5 = G ½-M G20 = G ¾-M G25 = G -M N08 = ¼" NPT-M N5 = ½" NPT-M N20 = ¾" NPT-M N25 = " NPT-M XX A = x Pt00 class B B = 2 x Pt00 class B C = x Pt00 class A D = 2 x Pt00 class A E = x Pt00 class B F = 2 x Pt00 class B G = x Pt00 class A H = 2 x Pt00 class A I = x Pt00 class B J = 2 x Pt00 class B K = x Pt00 class A L = 2 x Pt00 class A M = x Pt00 class /3 DIN (-70 N = x Pt00 class / 0 DIN (-70 O = x Pt00 class / 3 DIN (-70 P = x Pt00 class / 0 DIN (-70 Q = x Pt00 class ( ºC) RTD wiring 2 = 4 3) = 4-wire Terminal head G = screw-cap with I = screw-cap with chain, steel.440 P = screw-cap with chain, PP M ) = mini head screw-cap with K = head screw-cap, steel.440 B = DIN B screwed cover, Z = BUZ hinged cover, H = BUZ-H high model with hinged cover, E ) = head with LCD display and HART included D = with LCD display, steel.430 R = as D + 2 relay ) 2) 3) Only without Please specify the measuring range in clear text, while ordering With x Pt00 only 4) For A, B, C, D choose RTD wiring code '3' Note: Please specify length 'EL' in clear text, while ordering 4), only with ceramic terminal A 2) = 5333D B 2) = 5337D 4-20 ma with HART protocol C 2) = 5350A Profibus / Fieldbus D = prepared for subsequent mounting of Y = acc. to 9

10 HL=30 EL 2 ø0 HL=30 EL MWD-G compact with removable measuring insert ) and neck pipe, for mounting in thermowell Sensor element: Pt00 3-wire class B, A, /3, /0,, and others Neck pipe HL: 30 mm Electrical : M20x.5 Max. pressure: P atm only with thermowell TWL-0 Measuring insert: according to DIN 43772, filled with magnesium oxide (MgO) steel.4404 (36L) Dd Note: For order details of the thermowell see datasheet TWL-0. Without thermowell atmospheric pressure. ) Without protection MWD-G Measuring insert diameter (d) 3 = Ø3 4 = Ø4 G08 = G ¼-M G5 = G ½-M G20 = G ¾-M G25 = G -M N08 = ¼" NPT-M N5 = ½" NPT-M N20 = ¾" NPT-M N25 = " NPT-M XX A = x Pt00 class B B = 2 x Pt00 class B C = x Pt00 class A D = 2 x Pt00 class A E = x Pt00 class B F = 2 x Pt00 class B G = x Pt00 class A H = 2 x Pt00 class A I = x Pt00 class B J = 2 x Pt00 class B K = x Pt00 class A L = 2 x Pt00 class A M = x Pt00 class /3 DIN (-70 N = x Pt00 class / 0 DIN (-70 O = x Pt00 class / 3 DIN (-70 P = x Pt00 class / 0 DIN (-70 Q = x Pt00 class ( ºC) RTD wiring 2 = 4 3) = 4-wire 0 Terminal head G = screw-cap with I = screw-cap with chain, steel.440 P = screw-cap with chain, PP M ) = mini head screw-cap with K = head screw-cap, steel.440 B = DIN B screwed cover, Z = BUZ hinged cover, H = BUZ-H high model with hinged cover, E ) = head with LCD display and HART included D = with LCD display, steel.430 R = as D + 2 relay 4), only with ceramic terminal A 2) = 5333D B 2) = 5337D with HART protocol C 2) = 5350A Profibus / Fieldbus D = prepared for subsequent mounting of ) 2) 3) Only without Please specify the measuring range in clear text, while ordering With x Pt00 only 4) For A, B, C, D choose RTD wiring code '3' Note: Please specify length 'EL' in clear text, while ordering Y = acc. to /2-208

11 EL HL=50mm Dd MWD-W compact with removable measuring insert ) and neck pipe (nipple union nipple), for mounting in thermowell Sensor element: Pt00 3-wire class B, A, /3, /0,, and others Neck pipe HL: 50 mm, (nipple union nipple) Electrical : M20x.5 Max. pressure: P atm only with thermowell TWL-0 Measuring insert: according to DIN 43772, filled with magnesium oxide (MgO) steel.4404 (36L) Note: For order details of the thermowell see datasheet TWL-0. Without thermowell atmospheric pressure. ) Without protection Measuring insert diameter (d) 3 = Ø3 4 = Ø4 MWD-W N5 = ½" NPT-M XX A = x Pt00 class B B = 2 x Pt00 class B C = x Pt00 class A D = 2 x Pt00 class A E = x Pt00 class B F = 2 x Pt00 class B G = x Pt00 class A H = 2 x Pt00 class A I = x Pt00 class B J = 2 x Pt00 class B K = x Pt00 class A L = 2 x Pt00 class A M = x Pt00 class /3 DIN (-70 N = x Pt00 class / 0 DIN (-70 O = x Pt00 class / 3 DIN (-70 P = x Pt00 class / 0 DIN (-70 Q = x Pt00 class ( ºC) RTD wiring 2 = 4 3) = 4-wire Terminal head G = screw-cap with I = screw-cap with chain, steel.440 P = screw-cap with chain, PP M ) = mini head screw-cap with K = head screwcap, steel.440 B = DIN B screwed cover, Z = BUZ hinged cover, H = BUZ-H high model with hinged cover, E ) = head with LCD display and HART included D = with LCD display, steel.430 R = as D + 2 relay 4), only with ceramic terminal A 2) = 5333D B 2) = 5337D with HART protocol C 2) = 5350A Profibus / Fieldbus D = prepared for subsequent mounting of Y = acc. to /2-208 ) 2) Only without Please specify the measuring range in clear text, while ordering 3) 4) With x Pt00 only For A, B, C, D choose RTD wiring code '3' Note: Please specify length 'EL' in clear text, while ordering

12 ML MWD-M measuring insert Sensor element: Pt00 3-wire class B, A, /3, /0,, and others : ceramic terminal block or Max. pressure: atmospheric pressure Measuring insert: according to DIN 43772, filled with magnesium oxide (MgO) steel.4404 (36L) Dd Measuring insert diameter (d) 3 = Ø3 4 = Ø4 MWD-M 00 A = x Pt00 class B B = 2 x Pt00 class B C = x Pt00 class A D = 2 x Pt00 class A E = x Pt00 class B F = 2 x Pt00 class B G = x Pt00 class A H = 2 x Pt00 class A I = x Pt00 class B J = 2 x Pt00 class B K = x Pt00 class A L = 2 x Pt00 class A M = x Pt00 class /3 DIN (-70 N = x Pt00 class / 0 DIN (-70 O = x Pt00 class / 3 DIN (-70 P = x Pt00 class / 0 DIN (-70 Q = x Pt00 class ( ºC) RTD wiring 2 = 4 ) = 4-wire 2 Terminal head ) 2) With x Pt00 only Please specify measuring range in clear text while ordering. Only possible for wiring code '3' 3) For A, B, C, D choose RTD wiring code '3' Note: Please specify length 'ML' in clear text 3), only with ceramic terminal A 2) = 5333D B 2) = 5337D with HART protocol C 2) = 5350A Profibus /Fieldbus D = prepared for subsequent mounting of Y = acc. to /2-208

13 MWD-S Limited temperature depending on the selected cable Sensor element: Pt00 3-wire class B, A, /3, /0,, and others Max. pressure: 30 bar (at 20 ºC) only metallic immersion Protection : according to DIN steel.4404 (SS36L) Max. temp. cable: PVC max. 80 ºC silicone max. 200 ºC PTFE max. 220 ºC fiberglass 350 ºC Immersion diameter RTD wiring Cable Terminal MWD-S 3 = Ø3 ) 4 = Ø4 ) 00 K5 = compression fitting G ½-M C5 = compression fitting ½" NPT-M XX A = x Pt00 class B B = 2 x Pt00 class B C = x Pt00 class A D = 2 x Pt00 class A E = x Pt00 class B F = 2 x Pt00 class B G = x Pt00 class A H = 2 x Pt00 class A M = x Pt00 class /3 DIN (-70 N = x Pt00 class / 0 DIN O = x Pt00 class / 3 DIN (-70 P = x Pt00 class / 0 DIN Q = x Pt00 class ( ºC) 2 = 4 = 4-wire S = silicone T = teflon P = PVC F = fiberglass with steel braid connector = with spring strain relief Y = according to ) With pot seal Ø6 x 40 for crimping cable /

14 MWD-N Limited temperature depending on the selected cable Sensor element: Pt00 3-wire class B, A, /3, /0,, and others Max. pressure: 30 bar (at 20 ºC) only metallic immersion Protection : according to DIN : thread steel.4404 (SS36L) Max. temp. cable: PVC max. 80 ºC, silicone max. 200 ºC PTFE max. 220 ºC, fiberglass 350 ºC Immersion diameter RTD wiring Cable Terminal MWD-N 3 = Ø3 4 = Ø4 G08 = G ¼ M G5 = G ½ M G20 = G ¾ M G25 = G M N08 = ¼" NPT-M N5 = ½" NPT-M N20 = ¾" NPT-M N25 = " NPT-M XX A = x Pt00 class B B = 2 x Pt00 class B C = x Pt00 class A D = 2 x Pt00 class A E = x Pt00 class B F = 2 x Pt00 class B G = x Pt00 class A H = 2 x Pt00 class A M = x Pt00 class /3 DIN N = x Pt00 class / 0 DIN O = x Pt00 class / 3 DIN P = x Pt00 class / 0 DIN Q = x Pt00 class ( ºC) 2 = 4 = 4-wire S = silicone T = teflon P = PVC F = fiberglass with steel braid connector = with spring strain relief Y = according to 4 /2-208

15 MWD-I Limited temperature depending on the selected cable Sensor element: Pt00 3-wire class B, A, /3, /0,, and others Max. pressure: atmospheric pressure Handle: PVC material max. 80 ºC Protection : according to DIN steel.4404 (SS36L) Max. temp. cable: PVC max. 80 ºC silicone max. 200 ºC PTFE max. 220 ºC fiberglass 350 ºC Immersion diameter RTD wiring Cable Terminal MWD-I 3 = Ø3 4 = Ø4 000 = PVC handle XX A = x Pt00 class B B = 2 x Pt00 class B C = x Pt00 class A D = 2 x Pt00 class A E = x Pt00 class B F = 2 x Pt00 class B G = x Pt00 class A H = 2 x Pt00 class A M = x Pt00 class /3 DIN N = x Pt00 class / 0 DIN O = x Pt00 class / 3 DIN P = x Pt00 class / 0 DIN Q = x Pt00 class ( ºC) 2 = 4 = 4-wire S = silicone T = teflon P = PVC F = fiberglass with steel braid connector Y = according to /

16 MWD-P Limited temperature depending on the selected cable Sensor element: Pt00 3-wire class B, A, /3, /0,, and others Max. pressure: atmospheric pressure Handle: PVC material max. 80 ºC Protection : according to DIN steel.4404 (SS36L) Max. temp. cable: PVC max. 80 ºC silicone max. 200 ºC PTFE max. 220 ºC fiberglass 350 ºC Immersion diameter RTD wiring Cable Terminal MWD-P 3 = Ø3 4 = Ø4 000 = PVC handle XX A = x Pt00 class B B = 2 x Pt00 class B C = x Pt00 class A D = 2 x Pt00 class A E = x Pt00 class B F = 2 x Pt00 class B G = x Pt00 class A H = 2 x Pt00 class A M = x Pt00 class /3 DIN N = x Pt00 class / 0 DIN O = x Pt00 class / 3 DIN P = x Pt00 class / 0 DIN Q = x Pt00 class ( ºC) 2 = 4 = 4-wire S = silicone T = teflon P = PVC F = fiberglass with steel braid connector Y = according to 6 /2-208

17 MWD-T Sensor element: Pt00 3-wire class B, A, /3, /0 Max. pressure: atmospheric pressure Connection head: box or polycarbonate box Protection type: without holes outdoor installation with holes indoor installation Protection : according to DIN Max. temper. box: aluminum max. 80 ºC polycarbonate max. 80 ºC Aluminium Polycarbonate Immersion diameter RTD wiring Terminal head MWD-T H = Ø6 with holes 00 A = x Pt00 class B ( ºC) B = 2 x Pt00 class B ( ºC) C = x Pt00 class A ( ºC) D = 2 x Pt00 class A ( ºC) 2 = 4 = 4-wire A = P = polycarbonate 0 = ceramic terminal A = 5333D 4 20 ma B = 5337D 4 20 ma with HART protocol C = 5350A 4 20 ma Profibus / Fieldbus D = prepared for subsequent mounting of Y = according to /

18 Accessories / Description DOK-FR05 3-point calibration report (additional points possible) DOK-FR03 Inspection certificate 3. Ø 82 Ø 6,5 50 Protection: IP Typ 65G, I, P IP protection Typ M depends on cable gland. Higher IP on request. Ø 82 Ø 6, Ø Ø Ø Ø 39 Option K Housing material: steel.440 Typ H Protection: IP 65 Typ Z Housing material: Protection: IP Ø Ø Ø 23 Terminal s 38 Option G Housing material: 46 I Housing material: 3 steel.440 Ø 38 P Housing material: PP Option Z Note: Housing 38 material: Aluminium 9 Protection: Ø 34 IP 65 Ø 84 Ø 84 Ø Ø 27 Option M Ø Ø Ø Ø Ø 28 Ø 28 Typ K 8 Typ B , Ø Ø 34 Typ M Ø 9 /2-208

19 Terminal s (continuation) Option B Housing material: Protection: IP Ø 33 Ø Ø Ø 38 Ø 72 Ø 82 Option H Housing material: Typ G, I, P Protection: IP Ø 27 4 Typ H 55 8 Ø 39 Ø Technical Details Housing material: Supply voltage: V DC Output signal: ma Load: max. (V supply 7.5 V)/0.022 A Signal on alarm: underranging: linear drop to 3.8 ma overranging: linear rise to 20.5 ma sensor break, sensor open-circuit: 3.6 ma or 22 ma Galvanic isolation: 2000 V AC (input/output) Response time: s Long term stability: RTDs ±0.% of reading or 0. C Ø Ø 6,5 Switch delay: 5 s 38 Influence 9of ambient: negligible Load influence: Ø 34 negligible Power supply Typ M influence: negligible Filter configurating: μa Resolution: 0.3 μa Cable entry: M20 internal thread Ambient temperature: C ( F) Storage temperature: C ( F) Condensation: allowable Protection: IP 65 Shock and vibration resistance: 4g / 2 to 50 Hz as per IEC LCD-Display, with backlight: 55 visible range 32.5 x 22.5 mm; 8 main display: 5-digit, 7-segment, Ø 39 digit height 8 mm, range: Typ Z additional display: 8-digit 4 segment, digit height 5 mm for sensor type and units 83 Ø 27 4 Ø 84 Option E 60 Ø , Ø Ø ,5 Ø Ø 28 Main features Typ K OO High accuracy 0.02% of span for Pt00 sensor 0 O O Sensor error detection 82,5 according to the guidelines in NAMUR NE 89 OOBacklight LCD-Display Typ B 5 85 Ø 9 / , ºc 9

20 Terminal s (continuation) Option D/R Main Features p E Ø ºc OOGraphical display with backlight OOShowing errors and limits by steady or flashing colours OOProgrammable by touch screen OOOption R: two configurable relay outputs Technical Details Input Housing material: steel.430 Measuring range: ma (normal working range ma) Connections: 2 screw terminals for loop power, signal 4 screw terminals for relay outputs Accuracy: ±0.% of input span within C ±0.2% of input span within C / C Loop voltage drop: two levels depending on chosen backlight brightness at 20 ma: low bright backlight (<40%): max. 4 V at 23 C high bright backlight (>40%): max. 6.5 V at 23 C Sample time: s, typical 0.3 s Start-up time: 5 s User-configurable data Measuring range: ma Error/warning indication: Zoom on range: Damping: Linearisation table: Measuring unit (standard selectable): User defined unit: individually configurable display and backlight indication in white, green or red colour, steady or flashing light; configurable limits between 3.5 and 23 ma minimum 2 ma of input span s points C, F, K 8 x 20 pixels matrix 20 Dec. point position: xxxxx, xxxx.x, xxx.xx, xx.xxx, x.xxxx,.xxxxx, AUTO Display Type: FSTN graphically LCD Measuring range: Digit height: max. 22 mm Environmental conditions Optimal readability: C Operating temperature: C Storage temperature: C Mechanical data polycarbonate plastic Enclosure: ø 80 mm housing and front ring steel, AISI 304 Protection: IP 0 on terminals IP 67 in ø 80 mm housing Relay (option R) Contacts: Voltage: Load current: 2 solid state relays 60 Vp 75 ma /2-208

21 Electrical Connection x Pt00, x Pt00, 3-wire x Pt00, 4-wire 2 x Pt00, 2 x Pt00, 3-wire /

Thermal Mass Flow Meter for Gases

Thermal Mass Flow Meter for Gases Thermal Mass Flow Meter for Gases measuring monitoring analysing Direct mass flow rate measurement of gases Measuring accuracy: ±1.0% f.s. +0.5% m.v. pmax PN 16, tmax 175 C Fast response time No moving

More information

DOG-1/-3. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air : 120 C. p max. : PN 40; t max

DOG-1/-3. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air : 120 C. p max. : PN 40; t max Oscillation Flowmeter for gases measuring monitoring analysing DOG1/3 Measuring ranges: 0.2 20... 200 20000 m 3 /h air p max : PN 40; t max : 120 C Connection: flange DN 25... DN 400 Material: cast iron,

More information

TSK. Flap-Type Flowmeter. Range: to GPM Accuracy: ± 2.5% of Full Scale P max. : 580 PSI T max

TSK. Flap-Type Flowmeter. Range: to GPM Accuracy: ± 2.5% of Full Scale P max. : 580 PSI T max Flap-Type Flowmeter measuring monitoring analyzing TSK Range: 6.6...26.4 to 880...6600 GPM Accuracy: ± 2.5% of Full Scale P max : 580 PSI T max : -40 572 F Connection: Wafer Flange 1.5" 20" ASME Material:,

More information

DVZ. Vortex Flowmeter Compact. for low viscosity liquids. Range: l/min. Accuracy: ±2.5% of full scale. p max : 20 bar; t max : 80 C

DVZ. Vortex Flowmeter Compact. for low viscosity liquids. Range: l/min. Accuracy: ±2.5% of full scale. p max : 20 bar; t max : 80 C Vortex Flowmeter Compact for low viscosity liquids measuring monitoring analysing DVZ Range: 0.4. 000 l/min Accuracy: ±.% of full scale p max : 0 bar; t max : 80 C Connections: G ¼... G, ¼" NPT..." NPT

More information

Full Metal Variable Area Flow Meter and Counter

Full Metal Variable Area Flow Meter and Counter Full Metal Variable rea Flow Meter and Counter for horizontal and vertical mounting measuring monitoring analysing Special versions up to 600 bar Measuring range: 10-100...00-000 L/h water 0.3-3.0...-0

More information

Operating Instructions for Digital Manometer. Model: MAN-SD

Operating Instructions for Digital Manometer. Model: MAN-SD Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5

More information

Oscillation Flow Meter for Gases

Oscillation Flow Meter for Gases Oscillation Flow Meter for Gases measuring monitoring analysing Measuring ranges: 0.2 to 000 m 3 /h air pmax: PN 0, tmax: 0 C Connection: flange DN 25 DN 00 : Cast Iron, steel or stainless steel Accuracy:

More information

MIK. Electromagnetic Flowmeter Compact. for conductivity liquids. Range from liquids, acids and caustic solutions:

MIK. Electromagnetic Flowmeter Compact. for conductivity liquids. Range from liquids, acids and caustic solutions: Electromagnetic Flowmeter Compact for conductivity liquids measuring monitoring analysing MIK Range from liquids, acids and caustic solutions: 0.0-0. 3-700 l/min frequency-, switching-, analogue output

More information

Infrared Hand-Held Thermometers

Infrared Hand-Held Thermometers Infrared Hand-Held Thermometers measuring monitoring analysing Model: TIR-H... Measuring range from -2 to 5 C to -32 to 9 C Measuring accuracy: ±1% to ± 2% of measured value Option: analogue output, RS

More information

Industrial Pressure Transmitter

Industrial Pressure Transmitter ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter

More information

Infrared Hand-Held Thermometers

Infrared Hand-Held Thermometers Infrared Hand-Held Thermometers measuring monitoring analysing Model: TIR-H... Measuring range from -2... 5 C to -32... 9 C Measuring accuracy: ±1% to ± 2% of measured value Option: analogue output, RS

More information

Industrial Pressure Transmitter

Industrial Pressure Transmitter ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter

More information

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels TF 0 / TF 0-Ex Field mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.69 EN USA Input Resistance thermometer (,, wire circuit) Thermocouples

More information

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27 Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for

More information

Pressure transmitters for industrial applications MBS 32 and MBS 33

Pressure transmitters for industrial applications MBS 32 and MBS 33 Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer

More information

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO. DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link

More information

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8. TF / TF -Ex Field mounted temperature transmitters, PROFIBUS PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN P R O F I PROCESS FIELD BUS B U S Input Resistance thermometer (,, -wire

More information

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level

More information

MIK. Electromagnetic Flowmeter Compact. for conductivity liquids

MIK. Electromagnetic Flowmeter Compact. for conductivity liquids Electromagnetic Flowmeter Compact for conductivity liquids measuring monitoring analysing MIK MIK with frequency-, switching-, analogue output MIKwith digital plug on display Range from liquids, acids

More information

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar

More information

Hydraulic Pressure NAH Applications. Features. New generation available - refer to

Hydraulic Pressure NAH Applications. Features. New generation available - refer to NAH 8 Hydraulic Pressure Transmitter New generation available - refer to www.trafag.com/h70 Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for

More information

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement

More information

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up

More information

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC HYGRASGARD AFF - LC AFTF - LC sensors, calibrateable, with and active passive output Quality product for HVAC sector, accuracy % r.h. The calibrateable room humidity and temperature sensor HYGRASGARD KFF

More information

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

THM80X Series  Feature Application. Temperature & Humidity / Flow Measuring Specialist THM80X Series Feature Application IP67 protection degree, rugged aluminum case, fit in variety harsh environment Capable of temperature compensation Linear adjustment temperature & humidity by computer,

More information

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation S95.U0 / S95.U Head mounted temperature transmitters, programmable, Pt 00 (RTD), thermocouples, electrical isolation Resistance thermometer (,, wire circuit) Thermocouples Resistance remote signalling

More information

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30 eries Features Best pressure transmission solution for small and middle sized project such as indoor heating and air conditioning, water and sewer, or incinerator, etc. Improves noise resistance and minimize

More information

Exchangeable measuring insets SensyTemp TSA101

Exchangeable measuring insets SensyTemp TSA101 Contents Data Sheet Exchangeable measuring insets SensyTemp TSA101 for resistance thermometers and thermocouples Structure of electrical thermometers - Exchangeability during operation based on modular

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 07 Overview Function SITRANS LH00 Transmitter for hydrostatic level U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/

More information

Pressure Transmitter ED 701

Pressure Transmitter ED 701 Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

ATEX/IECEx RTD temperature probe

ATEX/IECEx RTD temperature probe Page 1/8 ATEX/IECEx RTD temperature probe with connecting cable acc. to DIN EN 60751 For temperatures from -100 to +600 C As single, double, or triple RTD temperature probe In two-wire, three-wire, or

More information

Temperature sensors SensyTemp TSP311, TSP321, TSP331

Temperature sensors SensyTemp TSP311, TSP321, TSP331 Contents Data Sheet Temperature sensors SensyTemp TSP311, TSP321, TSP331 Modular system - Measuring inset, thermowell, extension tube, connection head, transmitter - Supports numerous configurations Exchangeable

More information

HARTING D-Sub Selection Guide

HARTING D-Sub Selection Guide HARTING D-Sub Selection Guide People Power Partnership D-Sub Selection Guide D-Sub Device Connectivity HARTING Connectivity & Networks generates solutions throughout the triad of Installation Technology,

More information

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol with PROFIBUS-PA procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application 00 II () G FISCO The SINEAX VK 66 is a temperature transducer for use in aumation systems

More information

ISEmax CAM40/CAS40. Technical Information

ISEmax CAM40/CAS40. Technical Information Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works

More information

Relative pressure transmitter type 520

Relative pressure transmitter type 520 Relative pressure transmitter type 520 Pressure range The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the pressure measuring cell is fully

More information

Electromagnetic Flowmeter

Electromagnetic Flowmeter Overview Flokal B.V. smart electromagnetic flow meter is hallmarked by its high performance and reliability that are based on successful, field-proven technology. It s being widely used in industries such

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

Direct-operated 2/2-way compact solenoid valves Type EV210A

Direct-operated 2/2-way compact solenoid valves Type EV210A Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together

More information

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22) .2 Ex-Ceiling light fittings AB 8 / AB 5 LED / AB 5 / AB 12 NAV 7 (Zone 1, 2, 21, 22) The wall and ceiling light fixtures for particularly difficult operating conditions The impact-resistant and flameproof

More information

Direct-operated 2/2-way solenoid valves Type EV210B

Direct-operated 2/2-way solenoid valves Type EV210B Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance

More information

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181 Siemens AG 09 SITRANS F flowmeters System information Overview Siemens offers two types of ultrasonic flowmeters, in-line flowmeters and clamp-on flowmeters. This offers the end user the maximum flexibility

More information

S95.3U02 / S95.3U12. Head mounted temperature transmitters, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation

S95.3U02 / S95.3U12. Head mounted temperature transmitters, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation S95.U0 / S95.U Head mounted temperature transmitters, HART programmable, Pt 00 (RTD), thermocouples, electrical isolation Resistance thermometer (,, wire circuit) Thermocouples Resistance remote signalling

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output

More information

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure DATASHEET Pascal ET Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure - electrical signals (ma, mv, V, ) - temperature (TC and

More information

TF 212 / TF 212-Ex. Field mounted temperature transmitter, Profibus PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels. ABB Instrumentation

TF 212 / TF 212-Ex. Field mounted temperature transmitter, Profibus PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels. ABB Instrumentation TF / TF -Ex Field mounted temperature transmitter, Profibus PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN According to PROCESS FIELD BUS 0Input Resistance thermometer (,, -wire method)

More information

SINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol

SINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol SINEAX VK 66 for RTD and TC inputs, with HART procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application II () G SINEAX VK 66 is a two-wire head-mounted transmitter.

More information

Mineral-insulated thermocouples to DIN and EN

Mineral-insulated thermocouples to DIN and EN Data Sheet 90.1210 (90.1221) Page 1/7 s to DIN 43 710 and EN 60 584 for temperatures from -200 to +1200 C flexible sheath with shock-proof measuring insert protection tube diameter from 0.5mm fast response

More information

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH General information These connectors are designed and produced in conformity with the low-voltage directive (/3/EWG) respectively

More information

473 Dew Point Hygrometer

473 Dew Point Hygrometer High Performance Chilled Mirror Hygrometer With Cable Mounted Measuring Heads Highly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct

More information

Metso Concentration Measurement 3300

Metso Concentration Measurement 3300 Metso Concentration Measurement 3300 Metso Concentration 3300 Accurate direct in-line measurement The Concentration Measurement is provided with intelligent technology calculating the concentration of

More information

473-SHX Dew Point Mirror

473-SHX Dew Point Mirror Humidity and Temperature Reference Hygrometer For Temperature up to 125 C Precise and stable chilled mirror dew point mirror technology High temperature optical components High temperature sample fan Cable

More information

Field IT 50T Series Transmitters

Field IT 50T Series Transmitters Data Sheet SS/G/A_ Field IT 0T Series Transmitters gauge/absolute pressure transmitter Ranges: -00 to 0000kPa - to 00bar -. to 6000psi Base accuracy : 0.% (BFSL) Chemical Vapour Deposition (CVD) technology

More information

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series Amphenol Amphenol-Tuchel Electronics GmbH Circular Connectors C 09 A/B/D Series The Company Amphenol-Tuchel Electronics GmbH is a member of the USA based Amphenol Corporation. With our own global presence

More information

A BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET. SensyTemp TSA101 Exchangeable measuring insets

A BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET. SensyTemp TSA101 Exchangeable measuring insets A BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET SensyTemp TSA101 Exchangeable measuring insets 2 SENSYTEMP TSA101 EXCHANGEABLE MEASURING INSETS DS/TSA101-EN REV. E Measurement made easy Compatible

More information

473 Dew Point Hygrometer

473 Dew Point Hygrometer gh Performance Chilled Hygrometer With Cable Mounted Measuring Heads ghly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct insertion

More information

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

CALYS 80P. Field pressure calibrator with high accuracy 0.01% Field pressure calibrator with high accuracy 0.01% CALYS 80P is a field pressure calibrator within CALYS range with high accuracy of 0.01%. Description CALYS 80P is a field pressure calibrator within CALYS

More information

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,

More information

TH 202 / TH 202-Ex. Field mounted temperature transmitter, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation. ABB Instrumentation

TH 202 / TH 202-Ex. Field mounted temperature transmitter, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation. ABB Instrumentation TH 0 / TH 0-Ex Field mounted temperature transmitter, HART programmable, Pt 00 (RTD), thermocouples, electrical isolation 0/-8.6 EN Input Resistance thermometer (,, -wire circuit) Thermocouples Resistance

More information

Solenoid valves 2/2-way direct-operated type EV210A

Solenoid valves 2/2-way direct-operated type EV210A MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valves 2/2-way direct-operated type EV210A EV210A covers a wide range of small, direct-operated 2/2-way solenoid valves for use in industrial machinery.

More information

ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY

ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo 22 36054 Montebello Vicentino (VI) - ITALY www.abb.com/transformercomponents The information contained in this document is for general information

More information

Field mounted Temperature Transmitter TF212/TF212-Ex

Field mounted Temperature Transmitter TF212/TF212-Ex Data Sheet Field mounted Temperature Transmitter TF/TF-Ex PROFIBUS PA, Pt 00 (RTD), Thermocouples, or independent channels Input Resistance thermometer (,, -wire circuit) Thermocouples Resistance remote

More information

Absolute encoders multiturn

Absolute encoders multiturn elektronischer electronic multiturn, Multiturn, magnetic magnetisch Sendix M66 / M68 (shaft / hollow shaft) The Sendix M6 with Energy Harvesting Technology is an electronic multiturn encoder in miniature

More information

Size A DIN EN

Size A DIN EN Size A DIN EN 70-0 Actuators 0 series DIN EN 70-0 +, + ow and high housing Degree of protection IP6 Wired versions Moulded versions Degree of protection IP67 Contacts Thread Cable outlet Ordering-No. Female

More information

RoHS. Versatile. X g. X 2 e

RoHS. Versatile. X g. X 2 e s IN8, - and The inclinometers of the IN8 series allow measuring inclinations in the range of ±85 or -dimensional inclinations up to 0. With their high robustness, their protection level up to max. IP9k

More information

PRODUCT CATALOGUE PREssURE switch

PRODUCT CATALOGUE PREssURE switch PRODUCT CATALOGUE PREssURE switch w w w. p a a b. c o m Pressure AT THe HIGHesT LeVeL Successful mediumsized companies are not successful because they are active in many areas, but rather because they

More information

Conductivity sensor for hygienic applications

Conductivity sensor for hygienic applications Conductivity sensor for hygienic applications Type 8221 can be combined with Perfect for demanding applications in the hygienic industry (CIP and SIP compatible) Variants available for usage over a wide

More information

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure .13 Ex-Floodlights of the series / (Zone 2, 22) The powerful LED floodlights FMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all general lighting applications in

More information

SCTP20 Programmable 2-Wire Temperature Transmitter, Head Mount

SCTP20 Programmable 2-Wire Temperature Transmitter, Head Mount 20 Programmable 2-Wire Temperature Transmitter, Head Mount Configurable Transmitters Description Each 20 2-wire transmitter is designed for measuring temperature using thermocouples or RTDs. The input

More information

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006% ATEX documenting multifunction calibrator with high accuracy 0.006% is the top instrument of our range of ATEX documenting multifunction calibrators. Description is the top instrument of our range of ATEX

More information

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments .13 Ex-Floodlights of the series / / (Zone 2, 21, 22) The powerful LED floodlights FMV/nFMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all ge neral lighting applications

More information

EX-EMERGENCY LIGHT FITTINGS

EX-EMERGENCY LIGHT FITTINGS EX-EMERGENCY LIGHT FITTINGS nllk 0...N 1-36 W Plastic version for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 N are conform to the requirements of the ATEX-Directive

More information

PHOENIX CONTACT - 04/2016. Features

PHOENIX CONTACT - 04/2016. Features Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.

More information

Safir-M smart. Features. Dot-matrix display and controls. Industries. Applications. y Reference accuracy, % FS

Safir-M smart. Features. Dot-matrix display and controls. Industries. Applications. y Reference accuracy, % FS y Reference accuracy, % FS 0. 0.5 0.25 0.5 y Turndown :0 Features y Output 20 ma, 0 5 ma, HART 7.0 Linear (increasing or decreasing) Square root (differential pressure) y Damping predefined set (0; 0.5;

More information

Pressure. 1 Fitting PA R - N R2

Pressure. 1 Fitting PA R - N R2 INTERNAL STRUCTURE (R 1/4) 4 1 2 3 FEATURES High corrosion resistance and drip-proof construction port attachment made of Proven IP-65 grade gauge body (IP-65 in accordance with IEC) Standard product provides

More information

One-hand ph/temperature measuring instrument

One-hand ph/temperature measuring instrument One-hand ph/temperature measuring instrument testo 205 ph tip embedded in breakage-proof plastic ph Combined penetration tip with temperature probe Maintenance-free gel electrolyte C Measurement tip exchangeable

More information

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,

More information

Welcome. Functionality and application of RTD Temperature Probes and Thermocouples. Dipl.-Ing. Manfred Schleicher

Welcome. Functionality and application of RTD Temperature Probes and Thermocouples. Dipl.-Ing. Manfred Schleicher Welcome Functionality and application of RTD Temperature Probes and Thermocouples Dipl.-Ing. Manfred Schleicher This presentation informs about the basics of RTD Temperature Probes and thermocouples Functionality

More information

ph/o.r.p. probe Type 8619 multicell transmitter/controller General data Measuring range Bürkert ph probe Bürkert O.R.P. probe Medium temperature

ph/o.r.p. probe Type 8619 multicell transmitter/controller General data Measuring range Bürkert ph probe Bürkert O.R.P. probe Medium temperature ph/o.r.p. probe For many different types of installations and applications Large selection of probe for a wide range of holder Useable for pipe DN15 to DN200 Type 8203 can be combined with... Type 8200

More information

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I I nllk / I x W x W x W x W x W Technical data Cooper Crouse-Hinds - all rights reserved nllk / nllk nllk / nllk nllk / Marking to //EC II G Ex na II T / II D td A IP T C EC Conformity Statement PTB ATEX

More information

Heat Meter WR 200-D. 2 temperature inputs for Pt100 in four-wire circuit. Exact calculation of the heat parameters according IAPWS-IF97

Heat Meter WR 200-D. 2 temperature inputs for Pt100 in four-wire circuit. Exact calculation of the heat parameters according IAPWS-IF97 Heat Meter WR 200-D electronic computing device for heat quantity measuring Heat transfer medium water steam Any flow sensor with analog signal connectable 2 temperature inputs for Pt100 in four-wire circuit

More information

D5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder

D5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder with incremental encoder Draw wire encoder A40 Traverse speed max. 0.8 m/s The draw wire system A40 with incremental encoder excels with its compact construction. RoHS Compact and simple Measuring length

More information

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows: The basic PC software is supplied free with the recorder. There is an additional charge for the extensive Data Acquisition Software supplied with communication of RS-232/422/485 or Ethernet. The Ordering

More information

Facts and figures MULTILIFT SELECT 15

Facts and figures MULTILIFT SELECT 15 Facts and figures MULTILIFT SELECT 15 www.arburg.com MULTILIFT SELECT 15 Technical data min. 180 Stroke Z-axis Stroke X-axis Clamping face fixed mould platen 220 E A D K Stroke Y axis 195 B 2) C 157 P

More information

Construction and application of resistance thermometers

Construction and application of resistance thermometers Page 1/15 Construction and application of resistance thermometers Temperature-dependent resistance The variation of the electrical resistance of metals with temperature is very often employed for the electrical

More information

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50 /way ball valve with electric rotary actuator, ball valve in plastic, N 50 Suitable for aggressive media High flow rate value Actuator with adjustable limit switches Visual position indicator Type 0 can

More information

Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate

Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate Technical specification FLUXUS F502TE Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate Stationary ultrasonic clamp-on system for

More information

K04 TYPE -40 C +85 C 20000H

K04 TYPE -40 C +85 C 20000H K04 TYPE -40 C +85 C 20000H Extended life. Surge-proof capacitor in aluminium can with insulation sleeve. To be mounted with ring clips or with threaded stud. Designed for high resistances to voltage spikes.

More information

Non-Contact Safety Systems CMS

Non-Contact Safety Systems CMS Selection table for non-contact safety system // Evaluation units Connection Desi Read head contact assembly Assured switch-on distance S ao [mm] Assured switch-on distance S ar [mm] Number of outputs

More information

Linear measuring technology

Linear measuring technology Their extremely robust construction, their high IP69k protection level and their wide temperature range make these new draw wire encoders particularly reliable and durable. Their flexibility and adaptability

More information

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22) Ex-Floodlight PXLED (Ex-Zone 1, 2, 21 and 22) Lighting under harsh conditions The new modular LED floodlight series PXLED is suited for nearly every kind of lighting task in hazardous areas, including

More information

Display counter electromechanical

Display counter electromechanical Micro Display counter K 04... K 07, shock resistant 4-, 5-, 6- and 7 digit Micro adding counter High shock resistance Low power consumption; suitable for battery consumption small dimensions Large optical

More information

Technical specification FLUXUS F502TE

Technical specification FLUXUS F502TE Technical specification FLUXUS F502TE Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate Precise and intelligent energy measuring

More information

4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22)

4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22) .3 Ex-Pendant light fittings AB 5 / SPG 1N / AB 51 / EVI 2 / EVI 5 / EV35 LED (Zone 1, 2, 21, 2 The pendant light fitting series for a wide variety of applications The explosion-protected pendant light

More information

Surface-mounting Thermostats ATH Type Series

Surface-mounting Thermostats ATH Type Series Page 1/9 urface-mounting Thermostats ATH eries k enclosure protection IP 54 k tested to IN EN 14597 (replacing IN 3440) Brief description Thermostats control and monitor thermal processes. Instruments

More information

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components: SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine

More information

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application Type 2657...59 DN 10 up to 80 mm; Plastic; 2/2 way dvantages/benefits ntegrated pilot valves, position feed-back and limit switches available Customized system solutions with Burkert valves & sensors With

More information

Temperature Measurement

Temperature Measurement Temperature Measurement 157 12 Precise and reliable measurements even in aggressive liquids all probes are encapsulated with PTFE for maximum chemical resistance. PRODUCT TIPS Page 161: 143 PT100 Temperature

More information