1 ODU Advanced Military Connector Clarke & Severn Electronics Ph + sales@clarke.com.au

2 ODU AMC Advanced Military Connector Applications Defence and security PTT and PRR systems Ruggedized computers and hand-helds Nightvision Power supply Dismounted soldier Unmanned systems Land vehicles Software defined radios. Features Low weight Compact design Easy to handle Watertight Easy-Clean Robust Tested in accordance to MIL Blind mateable. All shown connectors are according to IEC :00 (VDE 0:00); connectors without breaking capacity (COC). ODU AMC is UL-listed under file E0. All dimensions are in mm. Some figures are for illustrative purposes only. Subject to change without notice. Errors and omissions excepted. We reserve the right to change our products and their technical specifications at any time in the interest of technical improvement. This publication supersedes all prior publications. Data transmission protocols These ODU specific connectors can transmit common data transmission protocols such as CAT, CAT A and USB.0, but they are not CAT- and USB standard connectors. This publication is also available as a PDF file that can be downloaded from Issue: 0-0 Page

3 Table of Contents Chapter From page Product description ODU AMC ODU AMC Standard version with Push-Pull or Break-Away function ODU AMC Standard version Details for the part number key ODU AMC Easy-Clean ODU AMC Easy-Clean Details for the part number key Accessories Technical information Page

4 For Your Notes Page

5 Product Description ODU AMC Product Description Page

6 Product Description Product Description Only the Best Solution Keeps You Running Since its founding in, ODU has developed and manufactured reliable connector systems for the military and defence sectors. These high-quality, innovative products are produced for the global market. ODU connectors are involved in many different sectors of the defence and military market, e.g. soldier communication systems, various Soldier of the future programmes, night vision systems, radio systems, radar systems, sonar systems for nuclear and non-nuclear submarines, weapon systems, portable navigation systems, launcher/rockets, aviation, battleships, armoured vehicles, etc. ODU has all necessary technologies under one roof, so we can respond to our customers requests flexibly and quickly. Design and development, tool manufacture, molding, stamping, turning, plating, assembly as well as cable assembly are all housed in our facility in Germany. Page

7 Product Description ODU AMC a Connection You Can Count On ODU is involved in soldier modernisation programs worldwide. In this field connectors must meet a number of rigorous conditions including ease-of-use and reliability under the most extreme conditions. ODU connectors meet and often exceed these by providing a reliable connection under the harshest of conditions. If you are looking for an innovative, robust, secure and reliable connector solution in the military/defence area ODU is your partner! Product Description To meet all requirements of the future ODU developed the military connector ODU AMC Advanced Military Connector. Group voice and data radio Excellent shielding High-speed up to 0 GBit Right-angled connector Navigation module Easy-Clean version Personal computer Small Light Colour coding possible Soldier control unit Cable to cable connection Vehicle adaption Page

8 Product Description Product Description Features ODU AMC Series Push-Pull locking or Break-Away function Lightweight, small and easy handling Operating temperatures range from C to + C Optimized mechanical and colour keying Lifetime of,000 mating cycles Easy handling and blind mateable Multiple contact configurations: signals, low/high voltage transmission, coax/triax Easy-Clean version available (see page ) System solution inclusive cable assembly and overmolding: everything from one source Excellent shielding features (0 ) Version for hot-plugging available Watertight protection class IP and IP K Excellent data transmission up to 0 GBit Page

9 Product Description ODU AMC Your Flexible Solution ODU AMC offers flexibility for all system engineers. Push-Pull and Break-Away versions are interoperable with the same receptacle and in-line receptacle. Cables could be changed later on without touching the receptacle (housing). The soldier has an option. Receptacle Push-Pull version In-line receptacle Product Description Break-Away version System Solution ODU provides all necessary cable assemblies and overmoulding tools. Standard solutions Application specific solutions Page

10 For Your Notes Product Description Page 0

11 ODU AMC either Push-Pull or Break-Away Function Page

12 Push-Pull Locking Principle Pulling on the cable Normal position. Position if someone pulls on the cable. Pulling on the cable the locking fingers grip tighter into the groove inside the receptacle. A separation is virtually impossible. Pulling on the plug housing Position if someone pulls on the outer housing. Demating of the connection. Pulling on the plug housing disengages the locking fingers from the receptacle groove and the connector separates easily. The advantages of Push-Pull connectors Quick and easy mating and demating Quick and easy separating Easy blind mating in difficult-to-reach places Less panel space required Definite and secure locking condition Page

13 Break-Away Function Pulling on plug or cable Connected position (fig. ). Demating of the connection (fig. ). Pulling on the cable with a certain force, the locking ring keeps the plug connected (fig. ). Pulling on the cable with more force, the plug will disconnect (fig. ). Break-Away forces depend on size and contact configuration. Additional information on request. The advantages of Break-Away function Disconnect in a hurry Quick and easy mating and demating Page

14 Push-Pull Plug Size 0 S Y R Dimensions in mm Size Size L L L L D D D SW A Max. cable ) A E. ) Based on cable with one braided shield. Size, = E; delivered with Band-It Band Technical data see page Contact configuration see page Cable assembly information see ODU instruction (available at /downloads/ assembly-instructions/). L L L L D D D Max. cable SW A Page

15 Break-Away Plug Size 0 A Y R Dimensions in mm Size Size L L L D SW A Max. cable ) A Based on cable with one braided shield. Technical data see page Contact configuration see page Cable assembly information see ODU instruction (available at /downloads/ assembly-instructions/). L L L D Max. cable SW A Page

16 In-Line Receptacle Size 0 K Y R Dimensions in mm Size Size L L L L D D SW A Max. cable ) A Based on cable with one braided shield. Technical data see page Contact configuration see page Cable assembly information see ODU instruction (available at /downloads/ assembly-instructions/). L L L L D Max. cable SW A D Page

17 Receptacle Connector Type 0 Y R L Size 0 Y R L Connector type Type G K For installation from rear of panel low profile inside the device Size L L Y X max. Size A page page page page Dimensions in mm Panel cut out +0. SW +0. D D SW A M SW Technical data see page Contact configuration and PCB layout see page IP, also in unmated condition. SW A Nutdriver for slotted nut Size Number Torque in Nm D Earth tag M D (A) Y L X L Page

18 Receptacle Connector Type 0 Y R L Size 0 Y R L Connector type Type Size L L max. Size L L X max. Dimensions in mm Panel cut out +0. SW +0. D D D SW A M SW G For installation from rear of panel low profile outside the device A E Technical data see page Contact configuration and PCB layout see page IP, also in unmated condition. D Earth tag D SW A M D Nutdriver for slotted nut Size part number Torque in Nm (A) (E) L L L X L Page

19 ODU AMC Details for the Part Number Key Keying Housing Material Contact Inserts Page

20 For Your Notes Page 0

21 Keying Possibilities Housing Material 0 Y R Y R P Keying Plug front view Colour keying Housing material Standard A Light brown R Aluminium EN-0 Ruthenium over electroless Ni B Red C Blue D Green Page

22 Contact Configurations Size Y R Size Insulator Number of contacts ) Contact diameter Nominal current load per contact ) Test voltage acc. SAE mm A Contact to contact kv Rated Termination View on the voltage ) termination side kv Solder Print Male contact side Female contact side 0 P P P P P High-speed inserts: ) ) CAT up to 00 Mbit P ) ) 0 USB.0 P U Male contact side P 0 Female contact side Maximal operating voltage at sea level up to,000 m acc. to SAE. More information see page. Max. current for solder termination / derating factor see page. Other contact configurations on request. Acc. IEC 0 : 00. Additional information on request. Acc. USB spec. rev..0 : 000. Additional information on request. For data transmission protocols, please refer to page Page

23 ODU AMC Contact type 0 Termination Solder Print 0 Y R Other termination or reverse gender on request. Contact diameter / Termination cross section 0 0 Y R Solder contacts ) Print contacts Contact type ) Contact diameter Contact type ) Contact diameter Term. cross section Other cross sections on request. Available connector type Socket W G GK K X S A Socket U G GK Termination cross section Termination diameter mm AWG mm mm 0. C D F G J G C F J 0 0. PCB Layout for Print Contacts Size 0 pos. Standard and high-speed pos. pos. pos. 0 pos Fig. G X (mm) Fig. GK Y (mm) Fig. : Length earth tag and pin G. Fig. : Length earth tag and pin GK. Earth tag.. Earth tag.. X Y Page

24 Contact Configurations Size 0 Y R Size Insulator Number of contacts ) Contact Nominal Test voltage diameter current load acc. SAE per contact ) in mm A Contact to contact kv Rated Termination View on the voltage ) termination side kv Solder Print Male contact side P P Female contact side P P High-speed inserts: ) ) CAT up to P Mbit ) ) CAT up to P D Gbit Maximal operating voltage at sea level up to,000 m acc. to SAE. More information see page. Max. current for solder termination / derating 0 factor 0 see page. 0 0 Other contact configurations on request. Acc. IEC 0 : 00. Additional information on request. For data transmission protocols, please refer to page Page

25 ODU AMC PCB Layout for Print Contacts Size Contact type 0. Y R Socket W G. GK K Solder. X S A Socket U0. G. GK Print.. Other termination or reverse gender. on request Termination Contact diameter / Termination cross section Y R Solder contacts ) Contact diameter... Contact type ) Contact diameter Term. cross section Termination cross section Termination diameter. mm.0 AWG mm mm 0. C D F G J G Print contacts. 0. C F J Other cross sections on request Fig. : Length earth tag and pin G Fig. : Length. earth tag and pin GK Earth. tag.0 Earth tag.0.. X Contact type ) Available connector type Y High-speed pos. High-speed pos. pos. pos. pos. pos Fig. G X (mm) Fig. GK Y (mm) Page

26 Contact Configurations Size. 0 A Y R Size Insulator Number of contacts ) Contact diameter Nominal current load per contact Test voltage acc. SAE mm A Contact to contact kv Rated Termination View on the voltage termination side kv Solder Print Male contact side A P A P High-speed insert Female contact side ) ) CAT A up to P D Gbit Maximal operating voltage at sea level up to,000 m acc. to SAE. More information see page. Max. current for solder termination / derating factor see page. Other contact configurations on request. Acc. IEC 0 : 00. Additional information on request. For data transmission protocols, please refer to page Page

27 ODU AMC PCB Layout for Print Contacts Size. Contact type 0 A Y R Fig. G Fig. GK Termination Solder Socket W G GK K X S A Print Socket U G. GK. Other termination or reverse gender on request. Contact diameter / Termination cross. section 0. A Y R Solder contacts ) Contact type ) Contact diameter Contact diameter Term. cross section Termination cross section. Termination diameter. mm AWG mm mm. 0. C D F G Contact type 0. ) Print contacts 0. C F Other cross sections on request Available connector 0.. type.. 0 pos. pos. High-speed pos Fig. : Length earth tag and pin G Earth tag. X X (mm) Y (mm) Fig. : Length earth tag and pin GK Earth tag.0 Y Page

28 Contact Configurations Size 0 Y R Size Insulator Number of contacts ) Contact diameter Nominal current load per contact ) Test voltage acc. SAE mm A Contact to contact kv Rated Termination View on the voltage ) termination side kv Solder Print Male contact side P Female contact side P P High-speed inserts: CAT A ) ) up to 00 Mbit P CAT A ) ) up to 0 Gbit P D Maximal operating voltage at sea level up to,000 m acc. to SAE. More information see page. Max. current for solder termination / derating factor see page. Other contact configurations on request. Acc. IEC 0 : 00. Additional information on request. For data transmission protocols, please refer to page. Page

29 .... ODU AMC PCB Layout for Print Contacts Size Contact type 0 Termination Solder Print Y R Contact diameter / Termination cross section 0 Y R Solder contacts ) Print contacts Contact type ) Contact diameter Contact type ) Contact diameter Term. cross section Other cross sections on request. Available connector type Socket W G GK K X S A Socket U G GK Other termination or reverse gender on request. Termination cross section Termination diameter mm AWG mm mm 0. C D F G J G 0.. P H C F J P 0 0. pos. pos. pos. High-speed pos. High-speed pos Fig. : Length earth tag and pin. G Earth tag Fig. G X (mm) Fig. GK Y (mm) Fig. : Length earth tag and pin GK Earth tag X Y Page

30 Contact Configurations Size 0 Y R Size Insulator Number of contacts ) Contact diameter Nominal current load per contact ) Test voltage acc. SAE mm A Contact to contact kv Rated Termination View on the voltage ) termination side kv Solder Print Male contact side P Female contact side P P P Maximal operating voltage at sea level up to,000 m acc. to SAE. More information see page. Max. current for solder termination / derating factor see page. Other contact configurations on request. Page 0

31 ... ODU AMC PCB Layout for Print Contacts Size Contact type 0 Y R P Termination Solder Print Contact type ) Contact type ). 0. Socket W 0. G K X S A Socket U G Other termination or reverse gender on request. 0 Contact diameter / Termination cross section Available connector type pos. pos Fig. G X (mm) Y R Solder contacts ) Contact diameter.. 0. Contact diameter Term. cross section Termination cross section Termination diameter mm 0. AWG mm mm 0. C D F G J G 0..0 T S.... Print contacts 0. C F J T Other cross sections on request pos. pos Fig. : Length earth tag and pin G Earth tag.0 X Page

32 Contact Configurations Size. 0 E Y R Size Insulator Number of contacts ) Contact diameter Nominal current load per contact ) Test voltage acc. SAE mm A Contact to contact kv Rated Termination View on the voltage ) termination side kv Solder Print Male contact side Female contact side E P Maximal operating voltage at sea level up to,000 m acc. to SAE. More information see page. Max. current for solder termination / derating factor see page. Other contact configurations on request. Page

33 PCB Layout for Print Contacts Size. Contact type 0 E Y R P Fig. G X (mm) Termination Solder Print Contact type ) Contact type ) Socket W G X S Socket U G Available connector type Other termination or reverse gender on request. pos Contact diameter / Termination cross section 0 E Y R Fig. : Length earth tag and pin G Earth tag.0 Solder contacts ) Contact diameter Contact diameter Term. cross section Termination cross section Termination diameter mm AWG mm mm 0. F G 0. X Print contacts Other cross sections on request. 0. F 0 0. Page

34 For Your Notes Page

35 ODU AMC Easy-Clean Easy-Clean Page

36 Easy-Clean ODU AMC Easy-Clean Version Easy-Clean version fast and easy cleaning of the connection in the field. Size 0 positions Size 0/ positions Size. positions All solder and print termination. Plug Intermateable with receptacle and in-line receptacle. Receptacle In-line receptacle Panel plug rear mount Easy-Clean Cable to cable connection available. The contacts within the Easy-Clean version are patented spring loaded contacts made by a leading swiss manufacturer. Page

37 Easy-Clean Break-Away Plug Size 0 A Y R 0 R Dimensions in mm Size L L L D SW A Max. cable ) Size A Based on cable with one braided shield. Technical data see page 0 Contact configuration see page Cable assembly information see ODU instruction (available at /downloads/ assembly-instructions/). L L L D Easy-Clean max. cable SW A Page

38 Easy-Clean In-Line Receptacle Size 0 K Y R 0 R Dimensions in mm Size L L L L D D SW A Max. cable ) Size A Based on cable with one braided shield. Easy-Clean Technical data see page 0 Contact configuration see page Cable assembly information see ODU instruction (available at /downloads/ assembly-instructions/). L L L L D max. cable SW A D Page

39 Easy-Clean Receptacle Connector type / style 0 Y R 0 R 0 0 L Size 0 Y R 0 R 0 0 L Connector type Style Size L L max. Size L Dimensions in mm X max. Panel cut out +0. SW +0. D D SW A M SW G K For installation from rear of panel low profile inside the device A Technical data see page 0 Contact configuration and PCB layout see page IP, also in unmated condition. Easy-Clean Earth tag SW A D M D Nutdriver for slotted nut Size part number Torque in Nm (A) L L X L Page

40 Easy-Clean Receptacle Connector type / style 0 Y R 0 R 0 0 L Size 0 Y R 0 R 0 0 L Connector type Style Size L L max. Size L L X max. Dimensions in mm Panel cut out +0. SW +0. D D D SW A M SW G For installation from rear of panel low profile outside the device A Easy-Clean Technical data see page 0 Contact configuration and PCB layout see page IP, also in unmated condition. Earth tag D SW A D M D Nutdriver for slotted nut Size part number Torque in Nm (A) L L L X L Page 0

41 Easy-Clean Panel Plug Rear Mount Connector type / style 0 Y R 0 R 0 0 L Size 0 Y R 0 R 0 0 L Connector type Style Size L L L X max. Size Dimensions in mm Panel cut out +0. SW +0. D D SW A M SW G W Panel plug rear mount A Technical data see page 0 Contact configuration and PCB layout see page IP, also in unmated condition. Easy-Clean Earth tag SW A D M D Nutdriver for slotted nut Size part number Torque in Nm (A) L L X L Page

42 For Your Notes Easy-Clean Page

43 ODU AMC Easy-Clean Details for the Part Number Key Keying Housing Material Contact Inserts Easy-Clean Page

44 Easy-Clean Keying Possibilities Housing Material 0 Y R 0 R Y R P 0 R 0 0 Keying Plug front view Colour keying Housing material Standard A Light brown R Aluminium EN-0 Ruthenium over electroless Ni B Red C Blue Easy-Clean D Green Page

45 Easy-Clean Spring Loaded Contacts Environmental Operating temperature range: stainless steel C to + C Materials Piston Gold plated machined brass Barrel Tin plated machined brass Spring Stainless steel Clip Gold plated BeCu C00 Mechanical Min. diameter 0. mm Min. initial height mm Travel / height ratio max. 0. Max. travel (stroke). mm Min. initial spring force 0. N Mechanical life ) 0,000 cycles Electrical Contact resistance ) max. 0 mohm Max. operating current ) A cont. / A peak Tested at nominal stroke with perpendicular pad connector area. Static measurement in halfway position of piston travel. Above max. current values are for single contacts in free air and for 0 C temperature rise. Values are indicative and may be affected by contact force, static or dynamic applications, shocks or vibrations. Easy-Clean Page

46 Easy-Clean Contact Configurations Size Y R 0 R 0 0 Size Insulator Number of contacts ) Contact diameter Nominal current load per contact ) Test voltage acc. SAE mm A Contact to contact kv Rated Termination View on the voltage ) termination side kv Solder Print Pogo-pin contact side Flat contact side 0 P Maximal operating voltage at sea level up to,000 m acc. to SAE. More information see page. Derating factor see page. Other contact configurations on request. Easy-Clean Page

47 Easy-Clean PCB Layout for Print Contacts Size 0 Contact type 0 0 Y R P 0 R 0 0 Fig. G Fig. GK Fig. GW X (mm) X (mm) X (mm) Termination Solder Print Contact type Contact type Available connector type Flat contact W A GW Spring load contact X G GK K Flat contact U GW Spring load contact V G GK pos Fig. : Length earth tag and pin G Earth tag. Fig. : Length earth tag and pin GK Earth tag. Contact diameter / termination cross section X X 0 Fig. : Length earth tag and pin GW 0 Y R P 0 R 0 0 Earth tag.0 Solder contacts Contact diameter Contact diameter Term. cross section Termination cross section Termination diameter mm AWG mm mm X Easy-Clean 0. D D 0. Print contacts 0. D 0 0. Page

48 ODU AMC Easy-Clean Contact Configurations Size Y R 0 R 0 0 Size Insulator Number of contacts ) Contact diameter Nominal current load per contact ) Test voltage acc. SAE mm A Contact to contact kv Rated Termination View on the voltage ) termination side kv Solder Print Pogo-pin contact side P Flat contact side P Maximal operating voltage at sea level up to,000 m acc. to SAE. More information see page. Derating factor see page. Other contact configurations on request. Easy-Clean Page

49 Easy-Clean PCB Layout for Print Contacts Size Contact type 0 Y R P 0 R 0 0 Fig. G Fig. GK Fig. GW.. X (mm) X (mm) X (mm) Termination Solder Contact type. Contact type 0. Available connector type Flat contact W A 0 GW Spring load contact X G GK K 0 pos Print Flat contact U GW Spring load contact V G GK.. 0. pos Contact diameter / termination cross section 0 Y R P 0 R 0 0. Fig. : Length earth tag and pin G Fig. : Length earth tag and pin GK Earth tag. Earth tag. Solder contacts Contact diameter Contact diameter Term. cross section Termination cross section Termination diameter mm AWG mm mm X X Fig. : Length earth tag and pin GW Earth tag.0 Easy-Clean 0. D D 0. Print contacts 0. D 0 0. X Page

50 ODU AMC Easy-Clean Contact Configurations Size A Y R 0 R 0 0 Size Insulator Number of contacts ) Contact diameter Nominal current load per contact ) Test voltage acc. SAE mm A Contact to contact kv Rated Termination View on the voltage termination side kv Solder Print Pogo-pin contact side Flat contact side A P Maximal operating voltage at sea level up to,000 m acc. to SAE. More information see page. Derating factor see page. Other contact configurations on request. Easy-Clean Page 0

51 Easy-Clean PCB Layout for Print Contacts Size. Contact type 0 A Y R P 0 R 0 0 Fig. G Fig. GK Fig. GW X (mm) X (mm) X (mm) Termination Solder Contact type Contact type Available connector type Flat contact W A GW Spring load contact X G GK K pos Print Flat contact U GW Spring load contact V G GK. Fig. : Length earth tag and pin G Earth tag. Fig. : Length earth tag and pin GK Earth tag. Contact diameter / termination cross section X X 0 Fig. : Length earth tag and pin GW A Y R P 0 R 0 0 Earth tag. Solder contacts Contact diameter Contact diameter Term. cross section Termination cross section Termination diameter mm AWG mm mm X Easy-Clean 0. D D 0. Print contacts 0. D 0 0. Page

52 For Your Notes Easy-Clean Page

53 Accessories Accessories Page

54 Accessories Protective Caps for Standard and Easy-Clean Version For receptacles G Size Part number Dimensions in mm A B C D L Crimp ferrule and lug are included. C B Crimp ferrule Cable lug. D A L For receptacles GK Size Part number Dimensions in mm A B C L Crimp ferrule and lug are included. Accessories Crimp ferrule Cable lug. A B C L Page

55 Accessories For in-line receptacles Size Part number Dimensions in mm A B C D L Crimp ferrule and lug are included. C B Crimp ferrule Cable lug. A D L For in-line receptacles Size Part number Dimensions in mm A B C L Crimp ferrule and lug are included. Crimp ferrule Cable lug. Accessories A B C L Page

56 Accessories For plugs Push-Pull plug and Break-Away plug S and A Size Part number Dimensions in mm A B C L Crimp ferrule and lug are included. Crimp ferrule Cable lug. A B C L Environmental and electrical characteristics Type Performance Standard Tightness IP IEC 0 Operating temperature C to + C IEC 0-- i+j Shielding effectiveness > db VG - Material Part Material Flammability Cap Conductive silicone UL (V) Lanyard Aramid UL (V0) Crimp ferrule, lug Brass, copper Shrinktube FPO (RNF-00) ASTM D (0 sec) Assembly information including tools see ODU instruction (available at com/downloads/assembly-instructions/). Accessories Page

57 Technical Information Page Technical Information

58 Technical Information Technical Data ODU AMC Standard Environmental and testing Type Performance Standard Tightness Sand and dust Operating temperature Thermal shock IP / m IP K Blowing sand and dust, settling dust IEC 0 / MIL-STD-0F./ DIN 000- MIL-STD-0F 0./ Procedure I / II DIN 000- / IPkx C up to IEC 0-- i+j + C ) C up to +0 C Humidity cyclic % up to %, up to C Low pressure (rapid decompression) Low pressure Icing Corrosion resistance. kpa to. kpa. kpa C Rime ice mm h salt mist, % salt solution, C EIA --E IEC 00-- MIL-STD-A Method 00. Type III IEC 00-- AECTP 00, Procedure III (STANAG 0) MIL-STD-0F 00./ IEC MIL-STD-0F./ EIA--B STANAG 0, AECTP 00-0 MIL-STD-0F 0./ Mould growth European fungus IEC Solar radiation 00-- Chemical endurance Several substances ) ISO 0- Including temperature rise due to contact load Substances listed at ODU datasheet Fig. Measurement points A A mv Mechanical data Type Performance Standard Mechanical endurance Electrical data Type Performance Standard Contact resistance (fig. ) over,000 mating cycles,000 mating cycles IEC 0---a EIA--0 Vibration MIL-STD Method 00 EIA-- Shock 00 g amplitude, half sine pulse of ms, no discontinuity > us Contact diameter / resistance 0. mm < mohm 0. mm < mohm 0. mm < mohm. mm < mohm.0 mm < mohm IEC 0-- Shell resistance (fig. ) < mohm IEC 0-- Insulation resistance > 00 MOhm IEC 0-- Shielding effectiveness ) > db VG - AY, GKY connector pair MIL-STD Method 00 EIA-- Fig. Measurement points A mv A Technical Information Page

59 Technical Information Material and surface treatments Material Standard Surface Standard Flammability EU Housing (conductive parts) Aluminium AlMgSiSnBi EN-AW 0 Ruthenium over electroless nickel Housing / nut (non conductive parts) Aluminium AlMgSiSnBi EN-AW 0 Black anodized US Backshell (Push-Pull plug) Backshell (Break-Away plug and in-line receptacle) Aluminium AlMgSiSnBi EN-AW 0 Ruthenium over electroless nickel Aluminium AlMgSiSnBi EN-AW 0 Electroless nickel SAE-AMS0 EMI-locking ring CuBe CW0C (.) Electrodeposited nickel Crimp sleeve CuZnPb. CW0N (.0) C00 Electrodeposited nickel Colour ring PSU UL (V0) Insulator PEEK UL (V0) contact Copper alloy CWN (.00) C00. µm gold over electrodeposited nickel MIL-G-0D Socket contact Copper alloy CWN (.00) C00. µm gold over electrodeposited nickel MIL-G-0D O-rings FVMQ (floursilikon) Potting potting compound UL (V0) Overmolding material TPU UL (HB) Shrink boots Polyester-elastomeer acc to. VG Page Technical Information

60 Technical Information Technical Data ODU AMC Easy-Clean Environmental and testing Type Performance Standard Tightness Sand and dust Operating temperature Thermal shock IP / m IP K Blowing sand and dust, settling dust C up to + C C up to +0 C Humidity cyclic % up to % up to C Low pressure (rapid decompression) Low pressure Icing Corrosion resistance. kpa to. kpa. kpa C Rime ice mm h salt mist, % salt solution, C Mould growth European fungus IEC Solar radiation 00-- Chemical endurance Several substances ) ISO 0- IEC 0 / MIL-STD-0F./ DIN 000- MIL-STD-0F 0./ Procedure I / II DIN 000- / IP kx IEC 0-- i+j EIA --E IEC 00-- MIL-STD-A Method 00. Type III IEC 00-- AECTP 00, Procedure III (STANAG 0) MIL-STD-0F 00./ IEC MIL-STD-0F./ EIA--B, STANAG 0, AECTP 00-0, MIL-STD-0F 0./ Mechanical data Type Performance Standard Mechanical endurance Electrical data Type Performance Standard Contact resistance (fig. ) over,000 mating cycles ),000 mating cycles ) IEC 0---a EIA--0 Vibration MIL-STD Method 00 EIA-- Shock 00 g amplitude, half sine pulse of ms, no discontinuity > us MIL-STD Method 00 EIA-- Contact diameter / resistance mm pogo pin < 0 mohm IEC 0-- Shell resistance (fig. ) < 0 mohm IEC 0-- Insulation resistance > 00 MOhm IEC 0-- Substances listed at ODU datasheet ,000 mating cycles, dependent on the specific application. Fig. Measurement points A mv A Fig. Measurement points A mv A Technical Information Page 0

61 Technical Information Material and surface treatments Material Standard Surface Standard Flammability EU US Housing (conductive parts) Aluminium AlMgSiSnBi EN-AW 0 Ruthenium over electroless nickel Nut Aluminium AlMgSiSnBi EN-AW 0 Black anodized Backshell Aluminium AlMgSiSnBi EN-AW 0 Electroless nickel SAE-AMS0 EMI-locking ring Stainless steel CW0C (.) Electrodeposited gold Crimp sleeve CuZnPb. CW0N (.0) C00 Electrodeposited nickel Colour ring PSU UL (V0) Insulator PEEK / PBT / PCT UL (V0) contact (pogo-pin) Copper alloy, CuBe, steel,. µm gold over electro deposited nickel (on piston) MIL-G-0D Socket contact Copper alloy CWN (.00) C00. µm gold over electrodeposited nickel MIL-G-0D O-rings FVMQ (floursilikon) Potting potting compound UL (V0) Overmolding material TPU UL (HB) Shrink boots Polyester-elastomeer Acc. to VG Page Technical Information

62 Technical Information Insulation Groups / Nominal Voltage / Test Voltage Insulation groups in acc. with DIN VDE 00 T/. Groups of connectors based on ambient and operating conditions. Example: A connector used in a shop environment falls into group B. (Laboratory environment would fall into Group A). Insulation group A0: For low power equipment in climate-controlled and dry rooms with only minimal heat rise when subjected to short circuit conditions. Insulation group A: For equipment operated in climate-controlled and dry rooms. Insulation group B: For equipment operated in living quarters, offices, and other commercial environments. Also for clean machine shops, laboratories, test stands, and medical environments. Insulation group C: Equipment primarily operated in industrial, commercial, and agricultural establishments. Non climate-controlled warehouses, workshops, boiler rooms and manufacturing floors. Insulation group D: Equipment operated on vehicles subjected to dirt, brake dust, and splash water or snow. Unprotected by housing. Determination of nominal voltage from test voltage in accordance with VDE 0 The following explains how to derive the nominal voltage from the test voltage (for practical purposes nominal voltage, rated voltage and reference voltage are the same.) The operating voltage must be less than the nominal voltage. Example: The selected connector has a test voltage of,000 VAC and will be operated in a clean mechanical shop environment (insulation group B). According the table below, the connector has a nominal voltage of 0 VDC (the example shows both printed in bold). Notice: According to MIL-STD-, Method 00 higher test voltages are acceptable (see next page). Table from DIN VDE 0 Reference voltage / nominal voltage Test voltage in Volt (AC 0 Hz) Insulation group in Volt (DC) in Volt (AC) A0 A B C D 00 0, ,000, ,000,00 0 0,000,0, ,0,0,0 0 0,000,0,0, ,000,0,000,0, ,0,0,00,00, ,00,0,0,00,00,00,000,0,0,00,00,00 Technical Information Page

63 Technical Information International Protection (IP) Classes in Accordance with DIN EN 0 (or IEC / VDE 00 T, respectively) Code letters (International Protection) IP First code number (Protection against solid foreign bodies) Second code number (Protection against water) Code number Extent of protection Code number Extent of protection 0 No protection No protection against contact, no protection against solid foreign bodies 0 No protection against water No protection against water Protection against large foreign bodies Protection against large-surface contact with the back of the hand, protection against foreign bodies 0 mm Protection against dripping water Protection against vertically falling water drops Protection against medium-sized foreign bodies Protection against contact with the fingers, protection against foreign bodies. mm Protection against dripping water when tilted Protection against falling water drops when tilted (any angle up to from the vertical) Protection against small foreign bodies Protection against contact with tools, wires, or the like with. mm, protection against foreign bodies. mm Protected against spraying water Protection against water spraying at any angle up to 0 from the vertical Protection against granular foreign bodies The same as, except mm Protection against splashing water Protection against splashing water from all directions Protection against dust deposits Protection against contact, protection against harmful dust deposit in the interior Protection against water jet Protection against water jet (nozzle) from any angle Protection against dust ingress Protection against foreign bodies mm, protection against dust ingress Protection against powerful water jet Protection against powerful water jet from any angle Protection against immersion Protection against water ingress during temporary immersion Protection against continuous immersion Protection against pressurized water during continuous immersion Protection against high pressure Protection against water from high-pressure/ steam jet cleaners. Page Technical Information

64 Technical Information Watertightness of the Series AMC Plug and in-line receptacle connection (case ) Overmolding Potting O-Ring O-Ring Potting Overmolding Plug and receptacle connection (case ) Overmolding Potting O-Ring O-Ring O-Ring Potting In mated condition the contacts are protected (in cases and ). In unmated condition the contacts can be protected using a protective cover (see page ). The cover must be removed before mating the plug with the receptacle. Protection against water through following seals Termination area Mated Unmated Position Position Cable Cable (Case ) Yes No Device Cable (Case ) Yes Yes Technical Information Page

65 Technical Information Conversions AWG Cross Section (AWG = American Wire Gauge) The AWG system describes the cross section of a wire using a gauge number for every % increase in conductor cross section. With larger wire diameters, the AWG gauge numbers decrease; as the wire sizes increase, the AWG gauge numbers decrease. This is only valid for solid conductors. Most wires are made with stranded conductors. Compared to solid conductors stranded wires offer higher durability, higher flexibility and better performance under bending and vibration. Stranded wires are made from wires with smaller gauge sizes (higher AWG gauge number). The AWG gauge number of the stranded wire is equal to that of a solid conductor of the same size wire. The cross section of the stranded conductor is the sum of cross sections of the single conductors. For example, a AWG-0 stranded wire of AWG- conductors has a cross section of 0. mm²; an AWG- 0 stranded wire with AWG- conductors has a cross section of 0. mm². Conversion table AWG/mm² Circular wire AWG Diameter Cross section Weight Max. resistance Inch mm mm² kg/km Ω/km 0 () (/) () (/) (/) () (/) (/0) () (/) () (/0) () (/) (/) () (/0) (/) () (/) (/) () (/) (/) () (/) (/0) () (/) (/) () (/0) (/) () (/) ,.00 () ,.00 (/) ,.00 () , () ,.0 () ,.00 () ,0.00 Page Technical Information

66 Technical Information Current Load Contacts Nominal single contact current load for pin / slotted socket (nominal diameter 0. mm. mm) Ø 0. mm Ø 0. mm Ø 0. mm Ø. mm Ø. mm 0 Measured temperature in C Load Current in Ampere Upper maximum temperature for contacts: + C. Test contact was terminated to largest possible conductor. Connectors or cables with more than one contact or conductor generate a higher heat than a single contact. Therefore, a derating factor must be applied. For connectors the derating factor is applied according to DIN IEC 0- / VDE The derating factor is used starting with loaded wires. Derating factor Number of loaded wires Derating factor Technical Information Page

67 Technical Information Operating Voltage acc. to SAE AS -Method 00. The values acc. to SAE AS -method 00. comply with MIL-Std. method 00. The chart values results are acc. to IEC 0-. The inserts have been tested in mated condition and the test voltage was applied to the pin insert. % of the measured break-down voltage is the basic for the further calculation. of this value is the corresponding operating voltage. All tests were performed at standard environment conditions (room temperature) and can be applied up to an altitude of,000 m. For any deviations one has to consider the reduction factor acc. to the relevant standards. Suitable safety precautions must be taken in order to ensure that personnel do not come into contact with live conductors during installation and operation. All entries were reviewed with maximum care before this catalogue was printed. ODU reserves the right to make changes in accordance with the current state of the art without advance notice, and without being obligated to provide replacement deliveries or to continue production of older designs. Test voltage: Break-down voltage 0. Operating voltage: Break-down voltage Caution Electrical appliances: for various applications the safety requirements regarding the operating voltage is even more severe! The relevant datas in such cases for the operating voltage are the creepage and clearance distances. For any advise how to chose the proper connector please consult us and indicate the safty standard which your product has to meet. Page Technical Information

68 For Your Notes Overview All Push-Pull Connector Series from ODU ODU MINI-SNAP L ODU MINI-SNAP K ODU MINI-SNAP B Push-Pull series Coding Sizes and groove and groove and groove No. of mechanical coding Diameter plug (mm) Max. cable (mm) Max. no. of contacts Solder Crimp Print IP Protection Class A) IP 0 IP IP IP Protection Class B) up to IP up to IP up to IP ODU MINI-SNAP S ODU MINI-SNAP F ODU AMC ODU MINI-SNAP PC Insulator Half shell and groove Half shell up to IP up to IP up to IP K up to IP up to IP up to IP IP IP 0 ODU MEDI-SNAP and groove.... up to IP IP 0 IP Protection Class in mated condition. IP Protection Class in unmated condition to the end device. Company Information Page

69 Quality Management Page Company Information

70 Your Partner in Many Application Areas MEDICAL ODU stands for quality, flexibility and reliability. This is why customers working in many application areas rely on ODU products in markets such as the following: INDUSTRIAL Medical Industrial Measuring and testing Military and security Energy emobility. MEASURING AND TESTING MILITARY AND SECURITY ENERGY Company Information EMOBILITY Page 0

71 The Complete ODU Product Range Single contacts (round or flat) High current connectors Circular connectors with Push-Pull locking Modular rectangular connectors PCB connectors Robust connectors Disposable Systems Application specific solutions AMC Advanced Military Connector Cable assembly Page Company Information

72 Everything from one Source Each connection needs its individual cable. Make no compromises when it comes to the quality of the complete connection system. ODU gives you the complete system solution from one source, with no intermediary suppliers. Cable assembly is a very complex subject. It requires equal measures of expertise in the areas of connectors, cables and assembly. ODU meets all these requirements in full. Our competent assembly team tests the complete system according your specifications. Our assembly service promises you the same quality found in our connectors without compromises. ODU offers you all from one source 00 % final inspections Production in clean room acc. to EN ISO- possible Automatic processes (cutting, stripping, attaching) Extrusion possible with a hot-melt and high pressure/ temperature process Ultrasound welding EMC-compatible assembly Application specific labeling Widest range of potting possibilities for sealed systems Extruded cable crossovers. Advantages for the customer Modern manufacturing facilities in Mühldorf (Germany), Shanghai (China) and Sibiu (Romania) Reliability thanks to our company-wide quality strategy Products with durability and functional reliability Production according to UL (file: E) possible Inspections, such as crimp force monitoring, during production. Assembly instruction you will find on our website: /downloads/assemblyinstructions/ Standard solutions Application specific solutions Company Information Page

73 Application Specific Connectors Innovative, dynamic markets call for innovative connectors. As an expert for special applications and requirements, we develop forward-looking, appropriate connectors attuned to your needs! In spite of the global trend toward standardized connectors, there are always applications that call for an application specific solution. We accept this challenge and develop innovative products for our customers based on our many years of extensive know-how, our creativity and, not least, our high level of vertical integration. Technology access and technology mastery, combined with intensive cooperation with the user, form the basis for achieving success together. Design-to-cost is joined by design-for-application for the customer s benefit. Page Company Information

74 Page

75 Telefax Inquiry ODU AMC Fax-No.: + - ODU GmbH & Co. KG Pregelstr. Mühldorf a. Inn GERMANY Company:... Name:... Department:... Street:... City:... Phone:... Date... ODU AMC Summary of Technical Requirements ) Connector application ) Environment ) Connector type Plug Receptacle In-line receptacle ) Special version ) Style ) Size 0. (A). (E) ) Series Y Standard Y Easy-Clean ) Coding ) Number of positions 0) Termination Solder PCB ) Cross section of wire mm² AWG Cable diameter mm ) Operating temperature C max C min ) Electrical specs: Operating voltage V AC V DC Operating current A (constant) A (short-term) sec. ) Chemical resistance against ) Other requirements Required quantity Production quantity Page

76 The Part Number Key No. Description Coding 0 Type S = Push-Pull plug G = Receptacle K = In-line receptacle A = Break-Away plug Style,, K, W Size 0,, A,,, E Series Y = ODU AMC Keying (colour and mechanical) A D Material / surface of housing R = Ruthenium Material insulator 0 Contact configuration ( positions) Contact type / surface Contact diameter Termination cross section 0 Locking principle 0 =, see page R = Easy-Clean Version, see page Cover / nut 0 = Standard 0 Receptacle earth tag GK and G L Example plug 0 S Y A R P 0 X F G = Plug = Style = Size = Series Y = ODU AMC = Coding A = light brown = Ruthenium over Aluminium = Peek insulator, 0 = positions = Solder pin = Contact diameter 0. mm = Cross section AWG /0. mm = free (0) = Locking Push-Pull = free (0) = free (0) = free (0) Example receptacle 0 G Y A R P 0 W F G L = Receptacle = Style = Size = Series Y = ODU AMC = Coding A = light brown = Ruthenium over Aluminium = Peek insulator, 0 = positions = Solder pin = Contact diameter 0. mm = Cross section AWG /0. mm = free (0) = Locking Push-Pull / Break-Away = free (0) = free (0) = Earth tag Page

77 Please open Page

78 KOMMA Werbeagentur D- Mühldorf a. Inn ODU GROUP WORLDWIDE HEADQUARTERS ODU GmbH & Co. KG Pregelstraße, Mühldorf a. Inn, Germany Phone: + - 0, Fax: + -, zentral@odu.de SALES SUBSIDIARIES ODU Denmark ApS Phone: + sales@odu-denmark.dk ODU Japan K.K. Phone: sales@odu.co.jp ODU-UK Ltd. Phone: sales@odu-uk.co.uk ODU France SARL Phone: odu@odu.fr ODU Scandinavia AB Phone: + sales@odu.se ODU-USA, Inc. Phone: sales@odu-usa.com ODU Italia S.R.L. Phone: sales@odu-italia.it ODU (Shanghai) International Trading Co., Ltd. Phone: oduchina@odu.com.cn Further information and specialized representatives can be found at: /contact PRODUCTION AND LOGISTICS SITES Germany China Mexico Romania USA Otto Dunkel GmbH ODU (Shanghai) Connectors Manufacturing Co.Ltd ODU Mexico Manufacturing S.R.L. de C.V. ODU Romania Manufacturing S.R.L. ODU-USA, Inc. ODU North American Logistics Simply scan the QR code to download the entire brochure. ODU AMC / B / 0 / E > Stempelfeld nicht lackieren <

ODU AMC. ODU Advanced Military Connector.

ODU AMC. ODU Advanced Military Connector. ODU Advanced Military Connector ODU AMC Advanced Military Connector Applications Defence and security PTT and PRR systems Ruggedized computers and hand-helds Nightvision Power supply Dismounted soldier

More information

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH General information These connectors are designed and produced in conformity with the low-voltage directive (/3/EWG) respectively

More information

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series Amphenol Amphenol-Tuchel Electronics GmbH Circular Connectors C 09 A/B/D Series The Company Amphenol-Tuchel Electronics GmbH is a member of the USA based Amphenol Corporation. With our own global presence

More information

Amphenol Amphenol-Tuchel Electronics GmbH. C 091 A/B/D Series. Circular Connectors.

Amphenol Amphenol-Tuchel Electronics GmbH. C 091 A/B/D Series. Circular Connectors. mphenol mphenol-tuchel Electronics GmbH C 09 //D Series Circular Connectors www.industrial-amphenol.com Note from the CEO Ladies and Gentlemen, For over years mphenol has enjoyed success as the interconnection

More information

Imformation of C091D series

Imformation of C091D series Imformation of C09D series The QTY of contacts is -pin to -pin, the connection method for the thread type, pinhole connections for welding type, press-fit and PCB type. This series of connectors to prevent

More information

8D Series Common Section

8D Series Common Section MIL-DTL-38999 qualified crimp contacts - 1.27µm gold plated #22D type Part number Ø M39029/58 360 M39029/56 348 Conductor section AWG Conductor section mm² External Ø over insulator Min Max Min Max Min

More information

Product Series Specification Document

Product Series Specification Document Product Series 3.96mm pitch board-to-board connectors - Socket SCOPE This document covers 3.96mm socket connectors. The connector will perform to the specifications outlined. All tests have been performed

More information

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet: abc instruments international FLT5A Thermometer Land Instruments International Dronfield, S18 1DJ England Telephone: (1246) 417691 Facsimile: (1246) 41585 Email: infrared.sales@landinst.com Internet: www.landinst.com

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for

More information

Thermal-Magnetic Circuit Breaker 2210-T2...

Thermal-Magnetic Circuit Breaker 2210-T2... Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring

More information

Blower Motor 3P Connector

Blower Motor 3P Connector 1. Scope Blower Motor P Connector 1.1 Content This specification covers the requirements for product performance, test methods and quality assurance provisions of Blower Motor P connector. Applicable product

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for

More information

Connector~Tech Providing Harsh Environment Connector

Connector~Tech   Providing Harsh Environment Connector Connector~Tech www.connectortech.com.au Providing Harsh Environment Connector SOLUTIONS Tajimi TC18 series connectors are water-pro up to 30 meters in depth. Economical and highly reliable construction

More information

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available

More information

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2... Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed

More information

High Power Contacts - Up to 850A

High Power Contacts - Up to 850A 8 Series igh Power Contacts igh Power Contacts - Up to 850 esigned to meet the harshest military requirements where high power and shielding are needed. 3 aluminum shell sizes available Size 19 (450 max);

More information

2mm Hard Metric Connectors

2mm Hard Metric Connectors A KYOCERA GROUP COMPANY 2mm Hard Metric Connectors Contents Introduction........................................ Technical Specifications............................. 2 Multi-Line Module Connectors for

More information

Single Module EN4165 ARINC BACC 65 EN4165. The New Standard Connector for Aircraft equipment and cabin systems. Advantages

Single Module EN4165 ARINC BACC 65 EN4165. The New Standard Connector for Aircraft equipment and cabin systems. Advantages Single Module EN4165 ARINC 809 - BACC 65 EN4165 The New Standard Connector for Aircraft equipment and cabin systems. Advantages Light weight composite, modularity, color coded, push pull coupling are the

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T... Magnetic and Hydraulic-Magnetic Circuit Breaker 830-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of

More information

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

5SJ4...-.HG Circuit Breakers to IEC and UL 489

5SJ4...-.HG Circuit Breakers to IEC and UL 489 Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is

More information

DIM. A (+ 0,05 0,51) .135 ±.015 (3,43 ± 0,38) COMMON LUG INTEGRAL ASSEMBLY NUT, DO NOT REMOVE 1/4-32 UNEF-2A THREAD

DIM. A (+ 0,05 0,51) .135 ±.015 (3,43 ± 0,38) COMMON LUG INTEGRAL ASSEMBLY NUT, DO NOT REMOVE 1/4-32 UNEF-2A THREAD Multi-Deck SERIES 0 SERIES 0 0." Diameter, / Amp, Standard, Military SR FEATURES Proven Quality in Thousands of Applications Gold-plated Contact System 0,,, 0 and 0 Angle Options MIL Qualified Versions

More information

This specification covers the requirements for product performance, test methods and quality assurance provisions of FG Terminal.

This specification covers the requirements for product performance, test methods and quality assurance provisions of FG Terminal. DESIGN OBJECTIVES The product described in this document has not been fully tested to ensure conformance to the requirements outlined below. Therefore AMP Ltd makes no representation or warranty, express

More information

Qualification Test Report. Modular Plugs, Unshielded and Shielded

Qualification Test Report. Modular Plugs, Unshielded and Shielded Qualification Test Report 501-131013 26 JAN 16 Rev. A Modular Plugs, Unshielded and Shielded 1. INTRODUCTION 1.1. Purpose Testing was performed on modular plugs to determine their conformance to the requirements

More information

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER ISOCON-6 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting

More information

Table of Contents Pin-Configuration Selection Guide for HDE, HDS, & EFP

Table of Contents Pin-Configuration Selection Guide for HDE, HDS, & EFP Table of Contents -Configuration Selection Guide for HDE, HDS, & EFP Service Voltage Rating... Electrical Service Ratings... Ampacity Ratings by Contact... Electrical Service Ratings Explained... Operating

More information

PRELIMINARY PRODUCT SPECIFICATION. Part Number Product Description Doc Number

PRELIMINARY PRODUCT SPECIFICATION. Part Number Product Description Doc Number Page 1 PRELIMINARY Page 2 1.0 SCOPE. This specification covers performance, tests and quality requirements for the USB Type C Receptacle range. USB4050, USB4055, USB4060, USB4065. 2.0 PRODUCT NAME AND

More information

Amphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme

Amphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme Amphenol Amphenol-Tuchel Electronics GmbH Series C 146 Heavy Duty Connectors Core Programme The Company General information These connectors are designed and produced in conformity with the voltage directive

More information

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008 LV HRC fuse links Overview LV HRC fuses are used for installation systems in non-residential, commercial and industrial buildings as well as in switchboards of power supply companies. They therefore protect

More information

American Zettler AZ742 RELAY Datasheet

American Zettler AZ742 RELAY Datasheet American Zettler AZ74 RELAY Datasheet http://www.manuallib.com/american-zettler/az74-relay-datasheet.html FEATURES Dielectric strength 000 Vrms Low height:.7 mm Epoxy sealed version available 0 Amp switching

More information

Series Shrink Boot Adapters. Series Shrink Boot, EMI/RFI, Strain Relief. Series Shrink Boot, EMI/RFI, Shield Sock

Series Shrink Boot Adapters. Series Shrink Boot, EMI/RFI, Strain Relief. Series Shrink Boot, EMI/RFI, Shield Sock Product Selection Guide How For a complete Table of Contents please see the last page of this book Series 310 - Shrink Boot Adapters The adapters in this section are designed to accommodate lipped-type

More information

SIM Mono Module Push Pull Connectors

SIM Mono Module Push Pull Connectors SIM Mono Module Push Pull Connectors EN RINC 809 Immeuble le Doublon avenue Dubonnet 90 COURBEVOIE Cedex FRNCE Version. Tel : (0) 9 0 0 00 Fax : (0) 9 0 0 0 www. amphenol-airlb. fr PRESENTTION PRT NUMBERING

More information

32 Input AC Block I/O Module

32 Input AC Block I/O Module Input AC Module Cat. No. 79-A0 Series B Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air to flow through

More information

Absolute encoders multiturn

Absolute encoders multiturn elektronischer electronic multiturn, Multiturn, magnetic magnetisch Sendix M66 / M68 (shaft / hollow shaft) The Sendix M6 with Energy Harvesting Technology is an electronic multiturn encoder in miniature

More information

SPECIFICATION AND PERFORMANCE CHARACTERISTICS OF SCA-2 CONNECTOR SERIES

SPECIFICATION AND PERFORMANCE CHARACTERISTICS OF SCA-2 CONNECTOR SERIES SPECIFICATION AND PERFORMANCE CHARACTERISTICS OF SCA-2 CIRCUIT ASSEMBLY CORP. 18 THOMAS STREET, IRVINE, CA 92618-2777 Page No. 1 CONTENTS CLAUSE PAGE 1.0 SCOPE. 4 1.2 Description. 4 2.0 APPLICABLE DOCUMENTS

More information

HARTING D-Sub Selection Guide

HARTING D-Sub Selection Guide HARTING D-Sub Selection Guide People Power Partnership D-Sub Selection Guide D-Sub Device Connectivity HARTING Connectivity & Networks generates solutions throughout the triad of Installation Technology,

More information

SERIES 10 ELEKTRISCHE STECKVERBINDER FÜR MEERES- UND MARINETECHNIK HIGH PERFORMANCE UNDERWATER ELECTRICAL CONNECTORS

SERIES 10 ELEKTRISCHE STECKVERBINDER FÜR MEERES- UND MARINETECHNIK HIGH PERFORMANCE UNDERWATER ELECTRICAL CONNECTORS SERIES 0 ELEKTRISHE STEKVERINDER FÜR MEERES- UND MRINETEHNIK HIGH PERFORMNE UNDERWTER ELETRIL ONNETORS Leinestraße D-9 Neumünster Tel. +9 - - 98-0 Fax +9 - - 98 - http://www.gisma-connectors.de E-Mail:

More information

CDS. high density spring connection

CDS. high density spring connection CDS high density spring connection DENSTY STANDARD 1A CDS DENSTY A A spring connection CDS Series The originality of multipole connectors represents one of the core values of LE, a leading company in this

More information

Product Data Sheet PD-0037-B

Product Data Sheet PD-0037-B Product Data Sheet PD-0037-B 3M Shielded Compact Ribbon (SCR) Connector 3M Shielded Compact Ribbon (SCR) Boardmount Right Angle 36110-2220 XX 3 Electronic Solutions Division Page: 1 of 12 Table of Contents

More information

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION CONNECTOR CONNECTOR 1 of 6 CONNECTOR 1.0 SCOPE This Product Specification covers the dip type for 13pins slimline SATA receptacle connector. 2.0 PRODUCT DESCRIPTION 2.1 PRODUCT NAME AND SERIES NUMER(S)

More information

NR ROTARY RING TABLE: FLEXIBLE IN EVERY RESPECT

NR ROTARY RING TABLE: FLEXIBLE IN EVERY RESPECT NR FREELY PROGRAMMABLE ROTARY TABLES NR ROTARY RING TABLE All NR rings allow customer-specific drive motors to be connected NR ROTARY RING TABLE: FLEXIBLE IN EVERY RESPECT WHEN IT S GOT TO BE EXACT We

More information

Amphenol. BACKSHELLS For LJT, RNJ, RNJ LP, JT, TV-CTV, SC39 AND SJT connectors. For MIL-DTL series I,II,III and VG96912 connectors

Amphenol. BACKSHELLS For LJT, RNJ, RNJ LP, JT, TV-CTV, SC39 AND SJT connectors. For MIL-DTL series I,II,III and VG96912 connectors Amphenol For LJT, RNJ, RNJ LP, JT, TV-CTV, SC39 AND SJT connectors For MIL-DTL-38999 series I,II,III and VG96912 connectors www.38999-solutions.com - www.amphenol-socapex.com

More information

The Working Environment

The Working Environment How How The Working Environment The broad range of backshell types available today makes it critical for interconnect engineers, and others tasked with the responsibility of specifying connector accessories

More information

MINIATURE MICROSWITCHES - PREMIUM

MINIATURE MICROSWITCHES - PREMIUM 0/08 MINIATURE MICROSWITCHES - PREMIUM V - 86 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed Broad range of operating forces

More information

Qualification Test Report

Qualification Test Report Qualification Test Report 501-97 28Jun10 Rev E Connector, Shielded, Miniature Circular DIN, PCB Mounted 1. INTRODUCTION 1.1. Purpose Testing was performed on Tyco Electronics Mini DIN Printed Circuit Board

More information

Data Sheet. ADJD-xMxx. High Power Light Strip, Ring & Round. Description. Features. Applications. Specifications

Data Sheet. ADJD-xMxx. High Power Light Strip, Ring & Round. Description. Features. Applications. Specifications ADJD-xMxx High Power Light Strip, Ring & Round Data Sheet Description Avago s Light Strip, Ring & Round Power LEDs range of products offers a series of LEDs which provides better lifetime robustness and

More information

High-ohmic/high-voltage resistors

High-ohmic/high-voltage resistors FEATURES These resistors meet the safety requirements of: UL1676 (range 510 kω to 11 MΩ) EN60065 BS60065 (U.K.) NFC 92-130 (France) VDE 0860 (Germany) High pulse loading capability Small size. APPLICATIONS

More information

fischer connectors General Catalogue Edition 5.2

fischer connectors General Catalogue Edition 5.2 fischer connectors Edition. General Catalogue SUMMARY Ordering Information Mechanical Specifications Electrical Specifications Thermocouple Connectors Part number system and definitions, Body styles Coaxial,

More information

Recommended Land Pattern: [mm]

Recommended Land Pattern: [mm] Dimensions: [mm] Recommended Land Pattern: [mm] Electrical Properties: Properties Test conditions Value Unit Tol. Capacitance 1 V/ 1 khz ± 0.2 khz C 150 nf ±10% Rated Voltage U R 310 V (AC) max. Rated

More information

High Ohmic/High Voltage Resistors

High Ohmic/High Voltage Resistors High Ohmic/High Voltage Resistors VR68 A metal glazed film is deposited on a high grade ceramic body. After a helical groove has been cut in the resistive layer, tinned electrolytic copper wires are welded

More information

MINIATURE MICROSWITCHES - PREMIUM

MINIATURE MICROSWITCHES - PREMIUM 0/06 MINIATURE MICROSWITCHES - PREMIUM V - 86 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed Broad range of operating forces

More information

Size A DIN EN

Size A DIN EN Size A DIN EN 70-0 Actuators 0 series DIN EN 70-0 +, + ow and high housing Degree of protection IP6 Wired versions Moulded versions Degree of protection IP67 Contacts Thread Cable outlet Ordering-No. Female

More information

DRS 61: Incremental encoders, number of lines and zero pulse width freely programmable DRS 60: Incremental Encoders with Zero-Pulse-Teach

DRS 61: Incremental encoders, number of lines and zero pulse width freely programmable DRS 60: Incremental Encoders with Zero-Pulse-Teach NEW DRS : Incremental encoders, number of lines and zero pulse width freely programmable DRS : s with Zero-Pulse-Teach Further highlights of this generation of encoders: Simple zero-pulse-teach by pressing

More information

WCAP-FTXX Film Capacitors

WCAP-FTXX Film Capacitors A Dimensions: [mm] B Recommended hole pattern: [mm] D1 Electrical Properties: Properties Test conditions Value Unit Tol. Capacitance 1 V/ 1 khz ± 0.2 khz C 0.1000 µf ± 10% Rated voltage U R 310 V (AC)

More information

Precision Leaded Resistors

Precision Leaded Resistors FEATURES Approved according to CECC 40101-806 Advanced thin film technology Low TC: ± 15 to Precision tolerance of value: ± 0.1 % and ± 0.25 % Superior overall : class 0.05 Wide precision range: 10 to

More information

Product Data Sheet PD-0053-A

Product Data Sheet PD-0053-A Product Data Sheet PD-0053-A 3M Mini D Ribbon (MDR) Connector MDR Surface Mount 102XX-1210 XE 102XX-1S10 XE Page: 1 of 11 Table of Contents 1.0 SCOPE...2 2.0 PRODUCT TESTED...2 3.0 GENERAL CONDITIONS...2

More information

Pressure Transmitter ED 701

Pressure Transmitter ED 701 Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation

More information

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop TECHNICA DATASHEET D-P--C Rope Safety Switches with reset for emergency stop Metal or polymer housing, from one or three conduit entries Protection degree IP6 In conformity with EN ISO 13850 contact blocks

More information

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C ASH & ALAIN INDIA PVT LTD S-00, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-000(India) Tel : 0-797575 Fax : 0-79757 E-mail : sales@ashalain.com Proximity Ideal for High Temperatures and Cleaning

More information

Operating Instructions for Digital Manometer. Model: MAN-SD

Operating Instructions for Digital Manometer. Model: MAN-SD Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5

More information

Recommended Hole Pattern: [mm]

Recommended Hole Pattern: [mm] Dimensions: [mm] Recommended Hole Pattern: [mm] Electrical Properties: Properties Test conditions Value Unit Tol. Capacitance 1 V/ 1 khz ± 0.2 khz C 680 nf ±10% Rated Voltage U R 400 V (DC) Insulation

More information

General characteristics

General characteristics General characteristics This range of insulators and partition bushings provides for connecting and supporting low- and medium-voltage electrical equipment. - Their purpose is to provide electrical and

More information

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION SCOPE 1.25mm 9(& 2$ 2 This specification covers the 1.25 mm PITCH WIRE TO BOARD CONNECTOR (DUAL TYPE) series PRODUCT NAME AND PART NUMBER

More information

16 Input AC Block I/O Module

16 Input AC Block I/O Module 6 Input AC Module Cat. No. 79-6A0 Series B Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air flow through

More information

Single Contacts. ODU Springtac Contacts and ODU Lamella Contacts. Ø 0,76 mm to Ø 60 mm

Single Contacts. ODU Springtac Contacts and ODU Lamella Contacts. Ø 0,76 mm to Ø 60 mm Catalogue No. 0-e Single Contacts ODU Springtac Contacts and ODU Lamella Contacts Ø 0, mm to Ø 0 mm rue René Laennec 0 Taissy France Fax: 0 0, Tel : 0 9 9 E-mail:hvssystem@hvssystem.com Site web : www.hvssystem.com

More information

ZF Series Force Transducers

ZF Series Force Transducers Data Sheet Series Force Transducers FEATURES 1 kn to 00 kn High accuracy For tensile or pressure forces Made of stainless steel Enclosure protection IP 67 DESCRIPTION The force transducers of the series

More information

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION Page 1 Page 2 1.0 SCOPE. This specification covers performance, tests and quality requirements for the SIM Card Connector SIM 2055 (Receiver Type, 6-Pin, SMT, 1.8 & 2.2mm Profiles). 2.0 PRODUCT NAME AND

More information

Conductivity sensor for hygienic applications

Conductivity sensor for hygienic applications Conductivity sensor for hygienic applications Type 8221 can be combined with Perfect for demanding applications in the hygienic industry (CIP and SIP compatible) Variants available for usage over a wide

More information

Installation guide 862 MIT / MIR

Installation guide 862 MIT / MIR Installation guide 862 MIT / MIR in combination with: 864 MTT or 863 MRT or (dual) spot element November 2005 Part no. 4416.232_Rev3 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100

More information

WIESON TECHNOLOGIES CO., LTD.

WIESON TECHNOLOGIES CO., LTD. TABLE OF CONTENT 1. Scope.... 2 2. Reference Documents. 2 3. Material and Components.... 2 4. Design and Construction.... 2 5. Rating.. 2 6. Performance and Test Descriptions. 2 7. Test Requirements and

More information

General-purpose Multi-Contact Circular Waterproof Connectors

General-purpose Multi-Contact Circular Waterproof Connectors General-purpose Multi-ontact ircular Waterproof onnectors RM-W Series Plug _ straight Ø. Ø Long backshell Overview High performance waterproof circular connectors and cable assemblies used in variety of

More information

Linear measuring technology

Linear measuring technology Their extremely robust construction, their high IP69k protection level and their wide temperature range make these new draw wire encoders particularly reliable and durable. Their flexibility and adaptability

More information

CONNECTORS, ELECTRICAL, RECTANGULAR, MICROMINIATURE, NON-REMOVABLE GAUGE 26 PCB PIN CONTACTS BASED ON TYPE 8MCG

CONNECTORS, ELECTRICAL, RECTANGULAR, MICROMINIATURE, NON-REMOVABLE GAUGE 26 PCB PIN CONTACTS BASED ON TYPE 8MCG Page 1 of 27 CONNECTORS, ELECTRICAL, RECTANGULAR, MICROMINIATURE, NON-REMOVABLE GAUGE 26 PCB PIN CONTACTS BASED ON TYPE 8MCG Issue 6 June 2018 Document Custodian: European Space Agency see https://escies.org

More information

SolderSleeve Devices Specification For Commercial Wire Splices. Table of Contents

SolderSleeve Devices Specification For Commercial Wire Splices. Table of Contents Page 1 of 15 SolderSleeve Devices Specification For Commercial Wire Splices Table of Contents Chapter Pages 1.0 General Requirements 1.1 Design of the Electrical Connection-Reminder Concerning The Approval

More information

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER CAUTION: This equipment is designed for connection to mains voltages and must be used in accordance with this guide. If it is not, the safety protection

More information

Pressure transmitters for industrial applications MBS 32 and MBS 33

Pressure transmitters for industrial applications MBS 32 and MBS 33 Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer

More information

Jun-2012 Rev A

Jun-2012 Rev A Design Objective 108-57912 01-Jun-2012 Rev A MINI USB CONNECTOR, RECEPTACLE, VERTICAL, DIP, B TYPE 1. SCOPE 1.1. Contents This specification covers the performance, tests and quality requirements for the

More information

3M Pak 10 Plug, PK10 series PK10-XXXPX-X-DA. 3M Pak 10 Socket, PK10 series PK10-XXXSX-X-DA

3M Pak 10 Plug, PK10 series PK10-XXXPX-X-DA. 3M Pak 10 Socket, PK10 series PK10-XXXSX-X-DA Page of 8 M Pak 0 Plug, PK0 series PK0-XXXPX-X-DA M Pak 0 Socket, PK0 series PK0-XXXSX-X-DA Product Specification Revised 08-0- Page of 8 Table of Contents Title Page.............................................................................

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer LDSR 0.3-TP/SP1 I P R N = 300 ma For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Closed

More information

Field IT 50T Series Transmitters

Field IT 50T Series Transmitters Data Sheet SS/G/A_ Field IT 0T Series Transmitters gauge/absolute pressure transmitter Ranges: -00 to 0000kPa - to 00bar -. to 6000psi Base accuracy : 0.% (BFSL) Chemical Vapour Deposition (CVD) technology

More information

Ÿ 9-50-way std density Ÿ way high Density Ÿ Mixed layout constructions ( e.g. 7W2, 9W4, 17W5) Ÿ Power constructions in 20A -40A ( e.g.

Ÿ 9-50-way std density Ÿ way high Density Ÿ Mixed layout constructions ( e.g. 7W2, 9W4, 17W5) Ÿ Power constructions in 20A -40A ( e.g. Ÿ 9-50-way std density Ÿ 15-78 way high Density Ÿ Mixed layout constructions ( e.g. 7W2, 9W4, 17W5) Ÿ Power constructions in 20A -40A ( e.g., 3W3, 5W5, 8W8) Ÿ Feed-through capacitor & pi filter constructions

More information

Recommended Land Pattern: [mm]

Recommended Land Pattern: [mm] Dimensions: [mm] 4 3 1 2 0,5 ref. 0,45 ref. Recommended Land Pattern: [mm] 1,2 0,5 0,35 0,85 0,9 0,85 Electrical Properties: Properties Test conditions Value Unit Tol. Impedance @ 100 MHz 100 MHz 120 Ω

More information

50 W Power Resistor, Thick Film Technology, TO-220

50 W Power Resistor, Thick Film Technology, TO-220 50 W Power Resistor, Thick Film Technology, TO-220 DESIGN SUPPORT TOOLS click logo to get started FEATURES 50 W at 25 C heatsink mounted Adjusted by sand trimming Leaded or surface mount versions High

More information

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en T20WN Torque transducers Data Sheet Special features - Nominal (rated) torques 0.1 N m, 0.2 N m, 0. N m, 1 N m, 2 N m, N m, 10 N m, 20 N m, 0 N m, 100 N m, 200 N m - Accuracy class: 0.2 - Contactless transmission

More information

V 12: Miniature photoelectric switches in M 12 housings

V 12: Miniature photoelectric switches in M 12 housings Lichtschranken Photoelectric Baureihe switcheswl 7- Photoelectric proximity switches Photoelectric reflex switches : iniature photoelectric switches in housings Through-beam photoelectric switches They

More information

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity VX Enclosure System Technical documentation PE conductor connection, current carrying capacity Enclosure system VX Contents Contents. General remarks. Introduction. Notes on the design of the earthing

More information

Universal limit switches

Universal limit switches SWITCHES.CROUZET.COM 1 LIMIT SWITCHES 0/016 Universal limit switches 8384 standard 8384 with positive break operation Conformity to standards IEC / EN 60947--1, including Annex K for version with positive

More information

E8EB-N0C2B E8EB-N0B2B

E8EB-N0C2B E8EB-N0B2B Slim Sensor CSM DS_E 1 Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree

More information

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS FEATURES AND BENEFITS* Up to 1,000,000 duty cycles or 10 year DC life 48V DC working voltage Active cell balancing Temperature output Overvoltage outputs available High power density TYPICAL APPLICATIONS

More information

Our Most Important Connection is with You. SECTION 8. Quick-Lock: QMA / WQMA / QN / QRE R123 / R123W / R164 / R324

Our Most Important Connection is with You. SECTION 8. Quick-Lock: QMA / WQMA / QN / QRE R123 / R123W / R164 / R324 SECTION 8 Quick-Lock: QM / WQM / QN / QRE R123 / R123W / R164 / R324 Contents QM and WQM Introduction... 8-4 to 8-5 Characteristics... 8-6 to 8-7 QM plugs and jacks... 8-8 to 8-9 QM receptacles...8-9 to

More information

H i g h A m p e r a g e 2 5 t o A M P. T y p e I & I I I V e h i c l e P r o t e c t i o n. I P 6 7 W a t e r p r o o f

H i g h A m p e r a g e 2 5 t o A M P. T y p e I & I I I V e h i c l e P r o t e c t i o n. I P 6 7 W a t e r p r o o f H i g h A m p e r a g e 2 5 t o 3 0 0 A M P T y p e I & I I I V e h i c l e P r o t e c t i o n I P 6 7 W a t e r p r o o f I g n i t i o n - P r o t e c t e d S A E & A B Y C C o m p l i a n t L E D T

More information

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS FEATURES AND BENEFITS* Up to 14 year DC life 56V DC working voltage Resistive cell balancing Overvoltage outputs High power density 4U, half-rack package UL registered TYPICAL APPLICATIONS UPS systems

More information

3M Pak 50 Boardmount Socket, P50 series P50-XXXS-XXX-EA. 3M Pak 50 Boardmount Plug, P50 series P50-XXXP-XXX-EA

3M Pak 50 Boardmount Socket, P50 series P50-XXXS-XXX-EA. 3M Pak 50 Boardmount Plug, P50 series P50-XXXP-XXX-EA Page of 8 3M Pak 50 Boardmount Socket, P50 series P50-XXXS-XXX-EA 3M Pak 50 Boardmount Plug, P50 series P50-XXXP-XXX-EA Product Specification 78-50-0-7 Revised 08-09- Page of 8 Table of Contents Title

More information

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up

More information

Product Specification

Product Specification Product Specification 2013-10-21 FPC Connector 0.5mm Pitch SMT Type Bottom Contact H:2.0 Update List: Item Update Description Rev. Issued Date Revisor 1 New Edit A 2013/10/21 DLITY Prepared By DLITY Rechecked

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer HO-NP series I P N = 4, 6, 12, 15 A Ref: HO 4-NP, HO 6-NP, HO 12-NP, HO 15-NP For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output

More information

Industrial Pressure Transmitter

Industrial Pressure Transmitter ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter

More information

BASE. Rotary limit switch. OptiOnS. FEAtuRES. CERtiFiCAtiOnS

BASE. Rotary limit switch. OptiOnS. FEAtuRES. CERtiFiCAtiOnS Rotary limit switch BASE Rotary limit switch used to control and measure the movement of industrial machines. Its compact size make it suitable for use in narrow spaces. FEAtuRES It consists of a gear

More information