fischer connectors General Catalogue Edition 5.2

Size: px
Start display at page:

Download "fischer connectors General Catalogue Edition 5.2"

Transcription

1 fischer connectors Edition. General Catalogue

2

3 SUMMARY Ordering Information Mechanical Specifications Electrical Specifications Thermocouple Connectors Part number system and definitions, Body styles Coaxial, triaxial, and multipole, Rear-mounted receptacles right-angle PCB contacts High voltage Coaxial and triaxial Multipole Mixed contacts Types and thermocouple materials A B C D E F G Cable Clamp Sets Accessories Wire Gauge Conversion (AWG) Assembly s Technical Information Mounting Instructions Assembly Instructions Recommended Cables Special Requirements Terms Index Clamps for screened and unscreened cables, for sealed connectors and insulating clamps Protective covers, bend reliefs, spacers, insulating, coding and grounding washers, crimp contacts, nuts Wrenches and crimping tools, contact insertion and extraction tools General mechanical and electrical ratings Hermetic sealing and environmental protection General cable assembly instructions Panel cut-out dimensions Coaxial and triaxial Multipole and high voltage multipole Table of coax and triax cable groups Questionnaire Warranty and Disclaimer Table of contents H J K L M N O P Q R S

4 ORDERING INFORMATION A Example: S 0 A0-0+ S SA SC Locking plug Plug with lanyard Clic-Loc plug D DEE DEU Panel receptacle Hermetic panel receptacle IP sealed receptacle DG DGP Completely threaded receptacle Completely threaded receptacle with PCB contacts SS SV SOV SF SFE SFU WS WSE Short plug Tamperproof plug Non-locking plug Non-locking panel plug Hermetic, non-locking panel plug IP sealed, non-locking panel plug Right-angle plug (replaced by WSO) Sealed right-angle plug (replaced by WSO) DB DBEE DBEU DBP DBPC DBPE DBPU Front projecting receptacle Hermetic, front projecting receptacle IP sealed, front projecting receptacle Rear-mounted panel receptacle Rear-mounted receptacle, right-angle PCB contacts Hermetic, rear-mounted panel receptacle IP sealed, rear mounted panel receptacle WDE K KE DK DKBE DKE Hermetic bulk-head feedthrough for connection of plugs Cable receptacle Sealed cable receptacle Panel-mounted cable receptacle Sealed rear-mounted cable receptacle Sealed, panel-mounted cable receptacle WSO Sealed right-angle plug S 0 A Connector Style Contact Protection Contact Configuration Options Cable Clamp Set As a general rule A Plugs have pins. Receptacles have sockets. See table of electrical ratings for corresponding type and series in sections D through F. See table of standardized suffixes on page A. See «Ordering Information» on page A and «Cable Clamp Sets», section H. Z Plugs have sockets. Receptacles have pins. Connector Size Dimension Cable Diameter Series A B C Dmax D ~A B C General dimensions of unsealed standard connectors. Except certain high voltage connectors listed in section C. See also page L. All dimensions shown are in millimeters and are for reference only.

5 BODY STYLES Plug Receptacle A S / SC D DB SA DBP SV DG DGP SOV DBPC Receptacle and Bulkhead feedthrough SS / SSC Right-angle plug DEE / DEU DBEE / DBEU WSO DBPE / DBPU WSE (obsolete) Cable receptacle WDE WS (obsolete) K / KE Panel plug DK SF DKE SFE / SFU DKBE

6 STANDARDIZED SUFFIXES ORDERING INFORMATION A Standardized Suffixes (Standard Code ) Insulator Contact Chrome Guide Material Termin. Plating Mark PTFE PBT crimp Standard Strain Relief Color for Cable Connectors White Black Green Blue Yellow Red Grey DBP, DBPE, DBPU with contacts natural red black white natural red black white natural red black white matt natural red PEEK black white natural red crimp black white Clamp Set Distribution Guide for Cable Connectors Series Multipole and Triax Connectors Coax, Mixed and High Voltage Connectors 0 S, K, DK - Clamp sets are included S, K, DK - Clamp sets are included } S, SA, SC, SV, SOV, WS, Clamp sets should be ordered WSE, WSO, separately, selected from K, DK, DKBE pages H - H and H - H0 KE, DKE Clamp sets are included, but clamp diameter should be added to the connector part number, separated by a / Mixed coax and high voltage connectors are listed on page H. The following list describes the different types of clamp systems available: Type «S» Type «U» Type «E» for Shielded cable, when the shield is to be terminated to the connector body. Shielded clamps can also be used for unshielded cable. for Unshielded cable, or where the shield is not to be terminated to the connector body. These clamps are available for series 0 through 0 and are slightly easier to assemble as there is only one piece instead of three. for Environmental applications, where the interface between cable and connector body must be sealed. This type of clamp can be used for both shielded and unshielded cables. Part number examples for Multipole and Triax: Plug S 0 A0-0 for cable of diameter.mm Shielded: Plug: S 0 A0-0+ Cable clamp: E 0. /. + B Unshielded: Plug: S 0 A0-0+ Cable clamp: E 0. /. Sealed: Plug: S 0 A0-0+ Cable clamp: E 0. /. + B Part number examples for coax connectors ofall Series: (For mixed contact connectors see page H) S 0 A0 /. SE 0 A0 /. For non-sealed coax connectors, the diameters are selected from the tables for shielded clamps «S» and for sealed coax connectors from the tables «E» on pages H - H

7 A

8 MECHANICAL SPECIFICATIONS PLUGS S SC Locking plug Clic-Loc plug B Unlike the fully-locking «S» plugs, the «SC» Clic-Loc plug snaps into the receptacle with a friction lock. dmax Series A B D Unsealed Sealed SV The dimensions in this section B are valid for coaxial, triaxial, and multipole connectors as well as for multipole high voltage connectors. For coaxial high voltage connectors with mixed contacts see section C. Tamper-proof plug A knurled locking ring with a set screw prevents unauthorized or unintentional disengagement. dmax Series A B D E Unsealed Sealed Please contact us for additional information SA Plug with lanyard dmax Series A B D Unsealed Sealed L L Please contact us for additional information For cable clamp sets see «Ordering Information» on page A and «Technical Infomation» on page L.

9 PLUGS MECHANICAL SPECIFICATIONS SS SSC Short plug Short Clic-Loc plug Series A B D D D dmax Please contact us for additional information 0 B Cable attachement possibilities: - Heat shrink or boots - Overmoulding Tables below give some references of various suppliers for heat shrink and boots. Type: straight tubes Series Raychem adhesive lined tube shrink ratio : or : Min cable sheath diameter 0 ATUM/-0 or ATUM/-0 / 0 0 ATUM/ ATUM/-0 0 ATUM-0 or ATUM/-0 / Type: straight boots Series Hellermann Tyton Min cable Raychem Min cable Raychem Min cable 00 Series w.lip sheath 0A Series sheath 0D Series sheath (MIL style) diameter no lip diameter strain relief w.lip diameter (--BWM0).0 0A D... 0 (0--BWM0) (0A--) (0D--0) A (0--BWM0) (0A--). 0D... (0D--0). Type: right angle boots Series Hellermann Tyton Min cable Raychem Min cable 00 Series w.lip sheath Series sheath (MIL style) diameter no lip diameter (--BWM0).0 A (0--BWM0) (A--) A (0--BWM0) (A--). All dimensions shown are in millimeters and are for reference only.

10 MECHANICAL SPECIFICATIONS NON LOCKING PLUG & PANEL PLUG SOV Non-locking plug B dmax Series A B D Unsealed Sealed Please contact us for additional information 0 For cable clamp sets see «Ordering Information» on page A and «Technical Infomation» on page L. SF Non-locking panel plug Series A Bmax C D F M x x 0 x 0 x 0.. x x TX x TX00.0 Panel plugs of series 0 and 0 are supplied with slotted nuts. For nut dimensions see «Accessories», section J. For wrenches see «Assembly s», section K. SFE SFU Hermetic, non-locking panel plug IP sealed non-locking panel plug Series A Bmax C D F M 0. x0. 0. x 0 Please contact us for additional information 0. x 0 0x 0 Please contact us for additional information 0

11 RIGHT-ANGLE PLUG MECHANICAL SPECIFICATIONS WSO Right-angle plug (Sealed or unsealed, depending on the type of cable clamp) Series A B D dmax E Please contact us for additional information 0 The acceptable maximum diameter (dmax) depends on the type of cable clamp (sealed or unsealed), see «Cable Clamp Sets for WSO» page H. B WS Right-angle plug (replaced by WSO) Series A B D dmax E WSE Sealed right-angle plug (replaced by WSO) Series A B D dmax E All dimensions shown are in millimeters and are for reference only.

12 MECHANICAL SPECIFICATIONS RECEPTACLES D Panel receptacle B High Voltage receptacles are listed in section C. Series A Bmax C D M 0. x0. 0. x 0 0 x 0. x 0 x 0 0 x TX x TX00.0 Receptacles of series 0 and 0 are supplied with slotted nuts. For nut dimensions see «Accessories», section J. For wrenches see «Assembly s», section K. DB Front projecting receptacle Series A Bmax C D F M 0 x x 0 Please contact us for additional information 0. x 0 x 0 Please contact us for additional information 0 The «DB» style allows the use of a protective sleeve on the mating straight plug thus providing a certain sealing. See «General Environmental Protection» on page M. DBP Rear-mounted panel receptacle Series A Bmax C D d E M x0. TC x TF x TG x TK x TP Please contact us for additional information 0 Solder pin length and diameter may vary in the same series. Please ask for exact sizes of dimensions A, C and E. Assembly tools for decorative slotted nuts are listed in section K.

13 RECEPTACLES MECHANICAL SPECIFICATIONS DGP Completely threaded receptacle with PCB contacts Serie A Bmax C d F M B 0 0. x0. TC x TF x TG x TK x TP Please contact us for additional information 0 DG Completely threaded receptacle Serie A Bmax d F M 0 x0. TC x TF x TG x TK x TP Please contact us for additional information 0 The bodies of the «DGP» and the «DG» are fully threaded, with the flange being replaced by a decorative slotted nut, allowing adjustment between PC Board and panel. The «DGP» is only available with PCB contacts. The «DG» is equipped with contacts and provides an aesthetic, uniform panel layout together with the DGP. Solder contact length and diameter may vary in the same series. Please ask for exact sizes of dimensions A, C and E. Assembly tools for decorative slotted nuts are listed in section K. All dimensions shown are in millimeters and are for reference only.

14 MECHANICAL SPECIFICATIONS SEALED RECEPTACLES DEE Hermetic panel receptacle DEU IP sealed panel receptacle For details concerning the degree of sealing see section M. For high voltage receptacles see section C. B For panel thickness less than Emin, spacers are available, listed under «Accessories», section J. Series A Bmax C D d Emin M x0. 0. x 0... x 0. x x 0 0 x TX x TX00.0 DBEE Hermetic, front projecting receptacle DBEU IP sealed, front projecting receptacle Receptacles of series 0 and 0 are supplied with slotted nuts. For nut dimensions see «Accessories», section J. Assembly tools see section K. The «DBEE» and «DBEU» style allows the use of a protective sleeve on the mating straight plug, thus providing a protection to the plug as shown on page M. Series A Bmax C D F M 0 0. x0. 0 x 0. x 0 0. x 0 x x TX x TX00.0 For details about sealing see section M. DBPE Hermetic, rear-mounted panel receptacle DBPU IP sealed, rear-mounted panel receptacle Series A Bmax D d E C M x0. TC x TG x TG x TK x TP Please contact us for additional information 0 Solder pin length and diameter may vary in the same series. Please ask for exact sizes of dimensions A, C and E. Assembly tools for decorative slotted nuts are listed in section K.

15 SEALED FEEDTHROUGHS MECHANICAL SPECIFICATIONS WDE Hermetic bulkhead feedthrough for connection of two plugs B Type Type Type Serie Type A Bmax C D Emin F M 0 x x 0 Please contact us for additional information 0 0 x 0 0 x 0 0x 0 0 x TX x TX00.0 The bulkhead feedthrough connector allows the traversal of a panel with electrical signals and power via two cable plugs. The «AZ» version of the feedthrough accepts a type «A» plug on the flange side and a type «Z» plug on the threaded end, which is typically oriented toward the interior of the chassis. In the version «ZA», the connections «A» and «Z» are inverted, see «Contact Protection» on page L. Dimension «Bmax» specifies the maximum panel thickness. For panels thinner than the unthreaded section «Emin» shown in Fig., we can provide spacers as shown in «Accessories», section J. Unlike the other series, the flange side of the «WDE 0» body (Fig.) does not contain an interfacial O-ring seal between the feedthrough and the mating plug. Feedthroughs of series 0 and 0 are supplied with slotted nuts. For nut dimensions see «Accessories», section J. Wrenches see under «Assembly s», section K. All dimensions shown are in millimeters and are for reference only.

16 MECHANICAL SPECIFICATIONS CABLE RECEPTACLES K KE Cable receptacle Sealed cable receptacle B Series A D dmax K KE DKBE Sealed rear-mounted cable receptacle Series A Bmax D E F dmax M 0.. x 0 0. x x x x x 0 0. x 0 0 For cable clamp sets see «Ordering Information» on page A and «Technical Infomation» on page L.

17 CABLE RECEPTACLES MECHANICAL SPECIFICATIONS DK Panel-mounted cable receptacle (replaced by DKBE) Series A Bmax C D dmax M 0.. x x 0 0 Please contact us for additional information 0 0. x x 0 0. x TX x 0 TX00.0 B DKE Sealed, panel-mounted cable receptacle (replaced by DKBE) For wall thickness less than Emin (Fig.) we offer spacers, listed under «Accessories», section J. Type Type Series Type A Bmax C D Emin F dmax M 0 0. x0. 0. x Please contact us for additional information 0 0. x x 0. 0x TX x 0 TX00.0 «DK» and «DKE» of series 0 and 0 are supplied with slotted nuts. For cable clamp sets see «Ordering Information» on page A and «Technical Infomation» on page L. All dimensions shown are in millimeters and are for reference only. 0

18 REAR-MOUNTED RECEPTACLES RIGHT-ANGLE P.C.B. CONTACTS ø A DBPC B ø B Type «A» SERIES REFERENCE NUMBER 0 Number of Contacts Diameter A [mm] Diameter B [mm] Length E [mm] (page B) Insulator Material DBPC 0 A PEEK DBPC 0 A PEEK DBPC 0 A PEEK DBPC 0 A PEEK DBPC 0 A PEEK DBPC 0 A0. 0. PEEK DBPC 0 A0. 0. PEEK DBPC 0 A PEEK DBPC 0 A PEEK DBPC 0 A PEEK DBPC 0 A PEEK 0 DBPC 0 A PEEK 0 DBPC 0 A PEEK 0 DBPC 0 A PEEK Electrical specifications see section E. «Contacts Layout» see on page B. = Standard

19 ACCESSORY MOUNTING CLAMP MECHANICAL SPECIFICATIONS DBPC 0 Assembly tool TC Accessory Mounting clamp Enables mounting directly to PCB with two. x screws Improves grounding of body to the PCB P/N 0. B Material: - Copper nickel plated - PBT Sectional View A-A see on page B DBPC 0 Assembly tool TF00.00 Accessory Mounting clamp Enables mounting directly to PCB with two. x screws Improves grounding of body to the PCB P/N 0. Material: - Copper nickel plated - PBT Sectional View A-A see on page B DBPC 0 Assembly tool TG00.00 Accessory Mounting clamp Enables mounting directly to PCB with two. x screws Improves grounding of body to the PCB P/N 0. Material: - Copper nickel plated - PBT All dimensions shown are in millimeters and are for reference only.

20 CONTACTS LAYOUT Contacts Layout, Sectional View A - A (See page B) B 0 DBPC 0 A0 DBPC 0 A0 DBPC 0 A0. Dia Dia Dia. 0. DBPC 0 A0 DBPC 0 A0. 0. Dia Dia DBPC 0 A0 DBPC 0 A0 DBPC 0 A0. Dia Dia Dia. 0. DBPC 0 A0 DBPC 0 A0 DBPC 0 A Dia Dia Dia DBPC 0 A00 Dia DBPC 0 A0.... Dia DBPC 0 A Dia. 0..

21 HIGH VOLTAGE MECHANICAL SPECIFICATIONS The mechanical specifications of high voltage connectors are listed separately in the three sections. The electrical specifications are included with the standard connector types as: Coaxial high voltage connectors under «Coax, Triax», section D Multipole high voltage connectors under «Multipole», section E Mixed high/low voltage connectors under «Mixed Contacts», section F Type «A» and «Z» With high voltage connectors, it is essential to pay attention to the differences between type «A» and «Z» connectors. Type «A»: The contacts of the receptacle are recessed to reduce the possibility of electric shock in the unmated position. Type «A»: This version should be used when the voltage is sourced from the receptacle. C Type «Z»: The contacts of the plug are recessed to reduce the possibility of electric shock in the unmated position. Type «Z»: This version should be used when the voltage is sourced from the plug. Protected contacts are usually female contacts recessed in the insulator. In some high voltage connectors, however, it is safer to recess the male contacts. In these cases, the plug type «A» is equipped with female contacts and the receptacle with protected male contacts. This applies to the multipole HT connector series: Example: 0 A0, 0 A0, 0 A0, 0 A0 and 0 A0 D 0 A0 S 0 A0 This also applies to the mixed HT connectors: Example: 0 A00, 0 A0, 0 A00, 0 A and 0 A0 D 0 A0 S 0 A0 Tamper-Proof Connectors SV/SVE To avoid unauthorized or unintentional disengagement of connectors, we offer plugs with an integral safety locking ring. When tightened, this knurled ring will prevent unmating of the plug. For an even greater level of safety, this ring can be immobilized with a simple hex wrench. This feature is especially suited for applications involving high voltage or current. For outside dimensions see pages B and C. Cable Clamp Sets Coaxial high voltage connectors are supplied with standard metal clamps. Most of the high voltage multipole and mixed contact connectors are fitted with insulating, one-piece clamps for optimal high voltage ratings. The termination of a cable screen to the connector shell and/or sealing of the cable to the connector shell is not possible with this clamp type. See «Insulating Cable Clamps» on page H. For terminating a shield or an anti-corona coating, metal collets for some cable diameters are available on request. Insulating collets see on page H. All dimensions shown are in millimeters and are for reference only.

22 MECHANICAL SPECIFICATIONS COAX HIGH VOLTAGE High voltage coaxial connectors are listed in the tables of «Electrical Specifications» in section D and are marked by «HT» in the column «Number of Contacts». The types which deviate from the standard dimensions are listed below When ordering these types of connectors, please always indicate the diameter of the cable dielectric. C This diameter is required additionally to the collet diameter in order to adapt the insulator to the cable. Suitable coax cables are indicated in the column «Cable Group» in section D. The cable specifications are listed on page Q. If required, we will supply adapter sleeves which must be placed over the cable dielectric during assembly in order to guarantee proper performance. For coaxial connectors, metal cable clamps are required with inner diameters as indicated for the appropriate series on pages H - H. For non-sealed coax connectors, the collet diameter has to be selected from the tables of type «S», and for sealed coax connectors from the tables of type «E» on pages H - H. S SE Locking plug Sealed locking plug TYPE A B D E 0 A0 0 Z0 dmax S / SV SE / SVE.. 0 A0 0 Z A0 0 Z A00 0 Z A00 0 Z SV SVE Tamper-proof plug Sealed tamper-proof plug 0 A00 0 Z00 0 A0 0 Z A knurled locking ring with a set screw avoids unauthorized or unintentional disengagement (see also page C). 0 A0 0 A00 0 Z00 0 A A0 0 Z0.. 0 The diameter «E» is only valid for the body styles «SV» and «SVE». Cable screen and jacket (e.g. RG-) are retained by hex-crimp to the plug shell. For improved safety, the center contact is further recessed than in the S 0 A0. Two wrenches with an opening of mm are required for SV/SVE 0 series.

23 COAX HIGH VOLTAGE MECHANICAL SPECIFICATIONS D Panel receptacle TYPE A Bmax C D M 0 A0 0 Z0 0 A0 0 Z0 0 A0 0 Z0 0 A00 0 Z00 0 A00 0 Z00. x0. x0.. x 0. x x C 0 A00 0 Z00 x 0 A0 0 Z0 x 0 A0 0 A00 0 Z00 0 A00 0 A0 0 Z0 x 0 x TX x TX x TX00.0 Also available with an optional micro switch. When ordering these receptacles, please always indicate the diameter of the cable dielectric. The receptacles of the 0 through 0 series are supplied with hex-nuts, receptacles of the 0 and 0 series with slotted nuts. For nut dimensions see «Accessories» in section J; for wrenches see «Assembly s» in section K. DEE Hermetic panel receptacle For vacuum sealed coax receptacles, PEEK should be specified for insulating material (see section D). TYPE A Bmax C D d Emin M 0 A0 0 Z0 0 A0 0 Z0 0 x0. 0. x0. 0 A0 0 Z0 0 A00 0 Z00 0 A00 0 Z00 0 A0 0 Z0 0 0 x x x x 0 A00 0 Z00. x TX A0 0 Z0 0. x TX00.0 For wall thickness less than «Emin» we offer spacers, listed under «Accessories», section J. All dimensions shown are in millimeters and are for reference only.

24 MECHANICAL SPECIFICATIONS MULTIPOLE HIGH VOLTAGE Multipole high voltage connectors are marked with «HT» in the tables of «Electrical Specifications», section E. C S Locking plug SE Sealed locking plug The multipole high voltage plugs have the same outer dimensions as the standard plugs shown on page B. The choice of type «A» and «Z» contacts is especially important for high voltage connectors. Important! An «A» type connector will not mate with a «Z» type connector. See page C and «Contact Protection» on page L. Most of the multipole high voltage connectors are supplied with insulating cable clamps. Tables of these types and of the available collet diameters are shown on page H. The termination of a cable screen to the connector shell is not possible with these insulating clamps. However, some connector types are available with special metal clamps which allow termination of the cable screen. S, SE 0 A0: The seven female contacts are supplied separatelly and must be inserted after being ed. For S, SE 0 A0: this purpose, we recommend tool No TP00.000, shown on page K. D Panel receptacle TYPE A Bmax C D M B max. 0 A0 0 Z0 0 A0 0 A0 0 Z0 0 A 0.. x 0.. x x x 0 A0 0 A0 0 Z0 0 A0 x x TX x TX00.0 Receptacles of 0 and 0 series are supplied with slotted nuts. For nut dimensions see «Accessories», section J. For wrenches see «Assembly s», section K. Other connector styles and contact configurations are available on request.

25 MIXED HIGH VOLTAGE MECHANICAL SPECIFICATIONS Mixed high and low voltage connectors are marked «HT» in the table of «Electrical Specifications», section F. S Locking plug TYPE A B D dmax 0 A0 0. C 0 A A0 0. For insertion of female high voltage contacts which have to be assembled after wiring, we recommend tool No TP00.000, shown on page K. Please note that the plugs of this group have a different shape than those of the standard version. These connectors are supplied with insulating cable clamps. The available inner diameters are listed on page H. The connection of a cable screen and/or a sealed cable entry is not possible with this clamp type. Some of these types, however, can be delivered with special metal clamps, allowing the clamping of a cable screen. D Panel receptacle TYPE A Bmax C D M 0 A0 x 0 A00 x 0 A0. x TX00.0 The D 0 A0 is supplied with a slotted nut. The required hook spanner No TX00.0 is shown on page K. For insertion of male high voltage contacts which have to be assembled after wiring, we recommend tool No TP00.00, shown on page K. 0 Series The high voltage center contact is retained in a special insulator. To achieve proper high voltage performance, the window for ing of the wire has to be covered by the supplied insulating tube, which must be placed over the cable before ing. All dimensions shown are in millimeters and are for reference only.

26 ELECTRICAL SPECIFICATIONS COAX TRIAX COAX TRIAX SERIES 0 0 REFERENCE NUMBER D 0 Connector Type Cable Group Contact Diameter A [mm] Wire Barrel Diameter B [mm] Insulating Material Contact Termination for Solder Crimp PCB Impedance [Ω] Test Voltage [kv] in mated position PTFE Insulator AC rms Center contact to Outer contact Outer contact to Body DC Center contact to Outer contact Outer contact to Body Max. Admissible Current [A] at 0 C Temperature Rise Max. Admissible Current [A] at 0 C Temperature Rise 0 A00 See catalogue Series 0 (NIM-CAMAC) 0 A00 0 TRIAX PEEK Executions on request 0 A00 COAX.. PTFE A00 0 Z00 COAX PTFE PTFE 0 A0 COAX PEEK 0 A0 COAX PTFE Z0 HT PEEK 0 A0 COAX 0 Z0 HT PTFE A0 TRIAX PTFE A0 TRIAX PTFE See list of recommended cables on page Q. Plug: Center contact - crimp / Outer contact - crimp ferrule Receptacle: Center contact - / Outer contact - washer with tag = Standard = Option

27 COAX TRIAX ELECTRICAL SPECIFICATIONS COAX TRIAX SERIES 0 0 REFERENCE NUMBER 0 0 A00 0 Z00 0 A00 0 Z00 Connector Type Cable Group Contact Diameter A [mm] Wire Barrel Diameter B [mm] Insulating Material Contact Termination for Solder Crimp PCB COAX.0.0 PTFE.. PTFE COAX..... PAI Impedance [Ω] Test Voltage [kv] in mated position PTFE Insulator AC rms Center contact to Outer contact Outer contact to Body DC Center contact to Outer contact Outer contact to Body Max. Admissible Current [A] at 0 C Temperature Rise Max. Admissible Current [A] at 0 C Temperature Rise D 0 A0 COAX 0 Z0 HT PTFE.. PEEK PAI 0 A0 COAX.. PTFE PTFE 0 A0 TRIAX PEEK 0 A0 TRIAX PTFE A00 COAX.. PTFE A00 COAX 0 Z00 HT.0. PTFE PAI A0 COAX.0. PTFE PEEK.. 0 A00 COAX.0. PTFE PEEK See list of recommended cables on page Q. Center contact - ;. screen - crimp;. screen - clamp = Standard = Option

28 ELECTRICAL SPECIFICATIONS COAX TRIAX D COAX TRIAX SERIES REFERENCE NUMBER 0 Connector Type Cable Group Contact Diameter A [mm] Wire Barrel Diameter B [mm] Insulating Material 0 A00 PTFE COAX.0. 0 Z00 PEEK Contact Termination for Solder Crimp PCB Impedance [Ω] Test Voltage [kv] in mated position PTFE Insulator AC rms Center contact to Outer contact Outer contact to Body DC Center contact to Outer contact Outer contact to Body Max. Admissible Current [A] at 0 C Temperature Rise Max. Admissible Current [A] at 0 C Temperature Rise A00 0 Z00 COAX.. PTFE..0 0 A00 COAX 0 Z00 HT PTFE PEEK 0 A00 0 Z00 COAX PTFE HT.0. PEEK.0 0 PAI COAX PTFE 0 A0 HT.0. PEEK 0 Z0 PAI 0 A0 COAX PTFE HT.0. PEEK A TRIAX.. PTFE A00 COAX 0 Z00 HT.0. PTFE 0 COAX 0 A00.0. PTFE HT 0 A0 COAX 0 Z0 HT 0 PTFE PAI See list of recommended cables on page Q. Receptacles are available with an optional micro switch. Plug and receptacle contain additionally recessed contacts. For detailed information, please ask for Triax Camera Connector Catalogue. = Standard = Option

29 MULTIPOLE ELECTRICAL SPECIFICATIONS Type «A» SERIES 0 REFERENCE NUMBER Number of contacts Contact Diameter A [mm] Wire Barrel Diameter B [mm] Insulating Material Contact Termination for Solder Crimp PCB Impedance [Ω] Test Voltage [kv] in mated position AC rms Contact to Body Contact to Contact Contact to Body DC Contact to Contact Max. Admissible Current [A] at 0 C Temperature Rise Max. Admissible Current [A] at 0 C Temperature Rise 0 0 A0 0 Z PEEK E 0 A0 0 Z PEEK A0 0 Z PEEK A0 0 Z PEEK A0 0 Z PEEK = Standard Plugs with crimp contacts must be used with unshielded clamps only, see on page H. For contact numbering see section P.

30 ELECTRICAL SPECIFICATIONS MULTIPOLE Type «A» SERIES 0 0 REFERENCE NUMBER 0 Number of contacts Contact Diameter A [mm] Wire Barrel Diameter B [mm] Insulating Material Contact Termination for Solder Crimp PCB Impedance [Ω] Test Voltage [kv] in mated position AC rms Contact to Body Contact to Contact Contact to Body DC Contact to Contact Max. Admissible Current [A] at 0 C Temperature Rise Max. Admissible Current [A] at 0 C Temperature Rise E 0 A0 0 Z0.. PEEK A0 0 Z0.. PEEK A0 0 Z PEEK A0 0 Z PEEK A0 0 Z PEEK A0 0 Z PEEK A0 0 Z PEEK A0 0 Z PEEK A00 0 Z PEEK A0 0 Z PEEK A0 0 Z PEEK For contact numbering see section P. = Standard

31 MULTIPOLE ELECTRICAL SPECIFICATIONS Type «A» SERIES 0 REFERENCE NUMBER 0 Number of contacts Contact Diameter A [mm] Wire Barrel Diameter B [mm] Insulating Material Contact Termination for Solder Crimp PCB Impedance [Ω] Test Voltage [kv] in mated position AC rms Contact to Body Contact to Contact Contact to Body DC Contact to Contact Max. Admissible Current [A] at 0 C Temperature Rise Max. Admissible Current [A] at 0 C Temperature Rise 0 A0 0 Z0.0.0 PTFE.. 0 E 0 A0 PEEK Z0 PTFE 0 A00 PEEK Z00 PBT A0 PTFE { 0 Z0 HT A0 0 Z0.. PEEK A PBT {.. 0 Z A0 0 Z0 HT PEEK A0 0 Z0.. PEEK..... = Standard = Option For contact numbering see section P.

32 ELECTRICAL SPECIFICATIONS MULTIPOLE Type «A» SERIES 0 REFERENCE NUMBER 0 Number of contacts Contact Diameter A [mm] Wire Barrel Diameter B [mm] Insulating Material Contact Termination for Solder Crimp PCB Impedance [Ω] Test Voltage [kv] in mated position AC rms Contact to Body Contact to Contact Contact to Body DC Contact to Contact Max. Admissible Current [A] at 0 C Temperature Rise Max. Admissible Current [A] at 0 C Temperature Rise E 0 A0 0 Z PEEK A PEEK Z0.. 0 A0 0 Z PEEK A PEEK 0 Z0 { A0 0 Z PEEK A0 0 Z PEEK A0 0 Z PEEK = Standard Test voltages between the contacts with shortest distance. For contact numbering see section P.

33 MULTIPOLE ELECTRICAL SPECIFICATIONS Type «A» SERIES 0 REFERENCE NUMBER 0 Number of contacts Contact Diameter A [mm] Wire Barrel Diameter B [mm] Insulating Material Contact Termination for Solder Crimp PCB Impedance [Ω] Test Voltage [kv] in mated position AC rms Contact to Body Contact to Contact Contact to Body DC Contact to Contact Max. Admissible Current [A] at 0 C Temperature Rise Max. Admissible Current [A] at 0 C Temperature Rise 0 A0 0 Z0.0.0 PEEK E 0 A0 0 Z0.0. PEEK A0 0 Z0.0.0 PEEK A0 HT.. PTFE A0 0 Z0.0.0 PEEK HT A + PTFE A0 0 Z0 HT.. PTFE { PEEK 0 A Z A0 PEEK Z0 PTFE 0 A0 PEEK { Contact dia.0 is positioned to make contact first and break last. = Standard = Option For contact numbering see section P.

34 ELECTRICAL SPECIFICATIONS MULTIPOLE Type «A» SERIES 0 REFERENCE NUMBER 0 Number of contacts Contact Diameter A [mm] Wire Barrel Diameter B [mm] Insulating Material Contact Termination for Solder Crimp PCB Impedance [Ω] Test Voltage [kv] in mated position AC rms Contact to Body Contact to Contact Contact to Body DC Contact to Contact Max. Admissible Current [A] at 0 C Temperature Rise Max. Admissible Current [A] at 0 C Temperature Rise E 0 A0 0 Z0 0.. PEEK A0 0 Z0.. PEEK A PEEK 0 Z0 { A HT.. PEEK { Conforms to IEC 00 Please contact us for additional information 0 A0 0 Z PEEK { PEEK 0 A Z A0 0 Z PEEK A0 0 Z PBT A0 0 Z PEEK Contacts with diameter. mm are positioned to make contact first and break last. Contacts with diameter. mm are positioned to make contact first and break last. For contact numbering see section P. = Standard

35 MULTIPOLE ELECTRICAL SPECIFICATIONS Type «A» SERIES 0 REFERENCE NUMBER 0 Number of contacts Contact Diameter A [mm] Wire Barrel Diameter B [mm] Insulating Material Contact Termination for Solder Crimp 0 A00 PTFE Z00 PEEK PCB Impedance [Ω] Test Voltage [kv] in mated position AC rms Contact to Body Contact to Contact Contact to Body DC Contact to Contact Max. Admissible Current [A] at 0 C Temperature Rise Max. Admissible Current [A] at 0 C Temperature Rise E 0 A0 0 Z0 HT.. PTFE A00 PTFE Z00 PEEK 0 A0 PTFE Z0 PEEK 0 A0 PTFE Z0 PEEK 0 A0 PTFE Z0 PEEK 0 A0 PTFE Z0 PEEK = Standard = Option The contact cups are specially insulated. Contact Number is positioned to make contact first and break last. For contact numbering see section P.

36 ELECTRICAL SPECIFICATIONS MULTIPOLE E Type «A» SERIES 0 REFERENCE NUMBER 0 Number of contacts Contact Diameter A [mm] Wire Barrel Diameter B [mm] Insulating Material Contact Termination for Solder Crimp Test Voltage [kv] in mated position PTFE 0 A PEEK 0 A0 PTFE Z0 PEEK PCB Impedance [Ω] AC rms Contact to Body Contact to Contact Contact to Body DC Contact to Contact Max. Admissible Current [A] at 0 C Temperature Rise Max. Admissible Current [A] at 0 C Temperature Rise 0 A0 HT.0.0 PTFE A0 PTFE Z0 PEEK 0 A0 PTFE Z0 PEEK 0 A0 PTFE Z0 PEEK 0 A0.. PTFE Z0 { PEEK = Standard = Option For contact numbering see section P.

37 ELECTRICAL SPECIFICATIONS Mixed Single & Multipole Connectors with Coaxial or High Voltage Contacts Type «A» SERIES REFERENCE NUMBER 0 Connector Type Cable Group Contact Diameter A [mm] Wire Barrel Diameter B [mm] Insulating Material Contact Termination for Solder Crimp PCB Impedance [Ω] Test Voltage [kv] in mated position AC rms Contact to Body Contact to Contact Contact to Body DC Contact to Contact Max. Admissible Current [A] at 0 C Temperature Rise Max. Admissible Current [A] at 0 C Temperature Rise COAX A0 PTFE COAX A0 PTFE F COAX A0 PTFE COAX A0 PTFE COAX A0 PTFE HT A00 PTFE HT A0 PEEK HT A00 PTFE HT A0 PTFE = Standard For more choice, please refer to the «Hybrid Connectors» catalogue. See list of recommended cables on page Q. Test voltages between contact and body as well as between contact and coaxial outer contact.

38 CONNECTORS FOR THERMOCOUPLES Fischer Connectors SA manufactures connectors in several body styles and sizes which are specifically designed for thermocouple applications. Most of these are also available in environmentally sealed versions, with either the «A» or «Z» contact polarity. The selection of the correct thermocouple contact materials is important in minimizing measurement errors. We can supply the following contact types suitable for thermocouple applications: Contacts made of different thermocouple materials Gold-plated copper alloy contacts For connectors with cable clamps, two versions are available: «M» version for semi-rigid cables in stainless steel tubes (Thermocoax ) «P» version for flexible compensation and extension cables Version «M» This version of the 0 series is designed to accept semi-rigid cables in stainless steel tubes (Thermocoax ). To facilitate assembly, the contact block of these connectors has a metal sleeve to which the thermocouple tubing is ed. The cable entry diameter «D» should be added to the reference number, which can be selected from the table on page G. Available body styles are shown in section A. Cable entries are available in increments of 0. mm from 0. to. mm diameter. Example: Note: Panel mounted cable receptacle, pole; NiCr - Ni, PTFE insulator, for. mm diameter semi-rigid cable. Part Number is DK 0 A00-M /. Standard Thermocoax cables up to mm diameter are now delivered with a mm diameter crimp ferrule with reinforced wires, providing easier assembly. This type of Thermocoax requires the use of the version «P» connectors. G Version «P» This version of the 0 series thermocouple connectors is furnished with a one-piece clamp which is designed to secure the flexible cables typically used for compensation or extension. It may also be used for Thermocoax cables with crimp ferrule termination. To order, the reference number of the thermocouple can be selected from the table on page G and the body style prefix from section A. For cable connectors, the part numbers of the cable clamp sets should be added as a second line item. These cable clamp sets are listed in the tables «U» on pages H - H. Example: Straight plug, pole, Fe - CuNi, PTFE insulator, for flexible cable with outer diameter of. mm: Part Number of the plug: «S 0 A00» and for the cable clamp: «E 0. /.» 0 Series Version «M» for THERMOCOAX Version «P» Contact block of version «M» for semi-rigid cables Contact block and cable clamp of version «P» for compensation cables and THERMOCOAX mm diameter + + D D D = Cable diameter max.. mm D = Cable clamp sets are ordered D = from tables «U» in section H In all versions, the longer contact termination is the electrically positive material.

39 CONNECTORS FOR THERMOCOUPLES SERIES Number Contact Designation and Contact Material of Diameter Contacts [mm] ANSI IEC + Designation Insulator Material Reference Number 0 0. K NiCr - Ni NiCr - NiAl Nickel/Chrom - Nickel Chromel - Alumel PTFE 0 A00 Ceramic 0 A00 PTFE 0 A00 CuZn Copper Alloy 0. + Ni/Au Nickel/gold plated Ceramic 0 A00 0. J Fe - CuNi Iron - Constantan PTFE 0 A00 0. T Cu - CuNi Copper - Constantan PTFE 0 A0 G 0. J Fe - CuNi Iron - Constantan PTFE 0 A0 NiCr - Ni Nickel/Chrome - Nickel. K PTFE 0 A0 NiCr - NiAl Chromel - Alumel. T Cu - CuNi Copper - Constantan PTFE 0 A00 0. J Fe - CuNi Iron - Constantan PTFE 0 A0 NiCr - Ni Nickel/Chrome - Nickel. K PTFE 0 A0 NiCr - NiAl Chromel - Alumel. J Fe - CuNi Iron - Constantan PTFE 0 A0 NiCr - Ni Nickel/Chrome - Nickel. K PTFE 0 A0 NiCr - NiAl Chromel - Alumel The designation «K» is applicable for both NiCr - Ni and for the registered trade name Chromel - Alumel. Chromel is an alloy of 0% Ni and 0% Cr; Alumel is an alloy of % Ni and small quantities of Mn, Al, Si, and others. Chromel (+) is non-magnetic. Alumel (-) is magnetic up to 0 C THERMOCOAX is a registered trade name of PHILIPS The above thermocouple alloys are in conformity with the Standards per (ANSI) IEC 0. Additionally to the plug «S» and the receptacle «D», other body styles like «SE, WS, WSE, DEE» etc. are available on request, and as type «Z».

40 CABLE CLAMP SETS 0 SERIES S Shielded Sleeve Shielded clamp Shielded cable clamps with sleeves. Cable Dia. Range Collet Diameter Cable Clamp Set. -.. E 0./. + A. -.. E 0./. + A. -.. E 0./. + A. -.. E 0./. + A. -.. E 0./. + A. -.. E 0./. + A A H U Unshielded Unshielded clamp Unshielded, one-piece cable clamps. Cable Dia. Range Collet Diameter Cable Clamp Set E 0./ E 0./ E 0./ E 0./ E 0./. E Environmental Sleeve Washer Seal Cable clamp To seal connectors order the following clamps for shielded or unshielded cables Cable Dia. Range Collet Diameter Cable Clamp Set. -.. E 0./. + B. -.. E 0./. + B. -.. E 0./. + B. -.. E 0./. + B. -.. E 0./. + B. -.. E 0./. + B For ordering information see page A. For technical details see pages L and N.

41 0 SERIES CABLE CLAMP SETS S Shielded Sleeve «A» for connectors with PTFE insulators Washer Shielded clamp Sleeve «B» for connectors with PEEK or PBT insulators Shielded cable clamps with washers and sleeves. Cable Dia. Range Collet Diameter PTFE insulator Cable Clamp Set PEEK or PBT insulator. -.. E 0./. + A E 0./. + B. -.. E 0./. + A E 0./. + B. -.. E 0./. + A E 0./. + B. -.. E 0./. + A E 0./. + B. -.. E 0./. + A E 0./. + B. -.. E 0./. + A E 0./. + B. -.. E 0./. + A E 0./. + B. -.. E 0./. + A E 0./. + B. -.. E 0./. + A E 0./. + B. -.. E 0./. + A E 0./. + B U Cable clamp «A» for connectors with PTFE insulators Unshielded H Cable clamp «B» for connectors with PEEK or PBT insulators Unshielded, one-piece cable clamps. Cable Dia. Range Collet Diameter PTFE insulator Cable Clamp Set PEEK or PBT insulator. -.. E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./. E Environmental Sleeve «A» for connectors with PTFE insulators Ring Washer Seal Cable clamp Sleeve «B» for connectors with PEEK or PBT insulators To seal connectors order the following clamps for shielded or unshielded cables. Cable Dia. Range Collet Diameter Cable Clamp Set PTFE insulator PEEK or PBT insulator. -.. E 0./. + A E 0./. + B. -.. E 0./. + A E 0./. + B. -.. E 0./. + A E 0./. + B. -.. E 0./. + A E 0./. + B. -.. E 0./. + A E 0./. + B. -.. E 0./. + A E 0./. + B. -.. E 0./. + A E 0./. + B. -.. E 0./. + A E 0./. + B. -.. E 0./. + A E 0./. + B All dimensions shown are in millimeters and are for reference only. For ordering information see page A. For technical details see pages L and N.

42 CABLE CLAMP SETS 0 SERIES S Shielded Sleeve Washer Shielded clamp Shielded cable clamps with washers and sleeves. Cable Dia. Collet Cable Clamp Set Range Diameter. -.. E 0./ E 0./ E 0./ E 0./ E 0./ E 0./ E 0./ E 0./ E 0./ E 0./. H U Unshielded Unshielded clamp Unshielded, one-piece cable clamps. Cable Dia. Range Collet Diameter Cable Clamp Set. -.. E 0./ E 0./ E 0./ E 0./ E 0./ E 0./ E 0./ E 0./ E 0./ E 0./. E Environmental Sleeve Ring Seal Washer Cable clamp To seal connectors order the following clamps for shielded or unshielded cables. Cable Dia. Range Collet Diameter Cable Clamp Set. -.. E 0./ E 0./ E 0./ E 0./ E 0./ E 0./ E 0./ E 0./ E 0./. For ordering information see page A. For technical details see pages L and N.

43 0 SERIES CABLE CLAMP SETS S Sleeve «A» for connectors with PTFE insulators Shielded Spacer Shielded clamp Sleeve «B» for connectors with PEEK or PBT insulators Sleeve «C» for K, DK with PEEK or PBT insulators Shielded cable clamps with washers and sleeves. Cable Dia. Range Collet Diameter PTFE insulator Cable Clamp Set Plug PEEK / PBT insulators K, DK E 0./.0 + A E 0./.0 + B E 0./.0 + C E 0./. + A E 0./. + B E 0./. + C. -.. E 0./. + A E 0./. + B E 0./. + C. -.. E 0./. + A E 0./. + B E 0./. + C. -.. E 0./. + A E 0./. + B E 0./. + C. -.. E 0./. + A E 0./. + B E 0./. + C U Cable clamp «A» for connectors with PTFE insulators Unshielded H Cable clamp «B» for connectors with PEEK or PBT insulators Unshielded, one-piece cable clamps. Cable Dia. Range Collet Diameter PTFE insulator Cable Clamp Set PEEK / PBT insulators. -.. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./. E Environmental Sleeve «A» for connectors with PTFE insulators Ring Washer Seal Cable clamp Sleeve «B» for connectors with PEEK or PBT insulators Sleeve «C» for K, DK, DKBE with PEEK or PBT insulators To seal connectors order the following clamps for shielded or unshielded cables. Cable Dia. Range Collet Diameter PTFE insulator Cable Clamp Set PEEK / PBT insulators E 0./.0 + A E 0./.0 + B E 0./.0 + C E 0./. + A E 0./. + B E 0./. + C. -.. E 0./. + A E 0./. + B E 0./. + C. -.. E 0./. + A E 0./. + B E 0./. + C. -.. E 0./. + A E 0./. + B E 0./. + C. -.. E 0./. + A E 0./. + B E 0./. + C Plug KE, DKE, DKBE All dimensions shown are in millimeters and are for reference only. For ordering information see page A. For technical details see pages L and N.

44 CABLE CLAMP SETS 0 SERIES S Shielded Sleeve «A» for connectors with PTFE insulators Spacer Shielded clamp Sleeve «B» for connectors with PEEK or PBT insulators Shielded cable clamps with washers and sleeves. Cable Dia. Collet Cable Clamp Set Range Diameter PTFE insulator PEEK / PBT insulators. -.. E 0./. + A E 0./. + B. -.. E 0./. + A E 0./. + B. -.. E 0./. + A E 0./. + B. -.. E 0./. + A E 0./. + B. -.. E 0./. + A E 0./. + B. -.. E 0./. + A E 0./. + B E 0./0.0 + A E 0./0.0 + B E 0./0. + A E 0./0. + B U Cable clamp «A» for connectors with PTFE insulators H Unshielded Cable clamp «B» for connectors with PEEK or PBT insulators Unshielded, one-piece cable clamps. Cable Dia. Collet Cable Clamp Set Range Diameter PTFE insulator PEEK / PBT insulators. -.. E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./0. E 0./0. E Sleeve «A» for connectors with PTFE insulators Environmental Ring Washer Seal Cable clamp Sleeve «B» for connectors with PEEK or PBT insulators To seal connectors order the following clamps for shielded or unshielded cables. Cable Dia. Range Collet Diameter Cable Clamp Set PTFE insulator PEEK / PBT insulators. -.. E 0./. + A E 0./. + B. -.. E 0./. + A E 0./. + B. -.. E 0./. + A E 0./. + B. -.. E 0./. + A E 0./. + B. -.. E 0./. + A E 0./. + B. -.. E 0./. + A E 0./. + B E 0./0.0 + A E 0./0.0 + B E 0./0. + A E 0./0. + B For ordering information see page A. For technical details see pages L and N.

45 0 SERIES CABLE CLAMP SETS S Shielded Sleeve Spacer Shielded clamp Shielded cable clamps and spacers for shielded or unshielded cables. Cable Dia. Range Collet Diameter Cable Clamp Set Cable Clamp Set Cable Dia. Collet Range Diameter Standard DKBE Standard DKBE. -.. E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./0. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./. H Sleeve Washer E Environmental Ring Seal Cable clamp To seal connectors order the following clamps for shielded or unshielded cables. Cable Dia. Range Collet Diameter Cable Clamp Set Cable Clamp Set Cable Dia. Collet Range Diameter Standard DKBE Standard DKBE. -.. E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./0. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./. All dimensions shown are in millimeters and are for reference only. For ordering information see page A. For technical details see pages L and N.

46 CABLE CLAMP SETS 0 SERIES Sleeve Spacer S Shielded Shielded clamp Shielded cable clamps and spacers for shielded or unshielded cables. Cable Dia. Range Collet Diameter Cable Clamp Set Cable Dia. Collet Cable Clamp Set Range Diameter H. -.. E 0./ E 0./ E 0./ E 0./ E 0./ E 0./ E 0./ E 0./ E 0./ E 0./ E 0./ E 0./ E 0./ E 0./ E 0./ E 0./. Sleeve Washer Ring Seal Cable clamp E Environmental To seal connectors order the following clamps for shielded or unshielded cables. Cable Dia. Range Collet Diameter Cable Clamp Set Cable Dia. Collet Cable Clamp Set Range Diameter. -.. E 0./ E 0./ E 0./ E 0./ E 0./ E 0./ E 0./ E 0./ E 0./ E 0./ E 0./ E 0./ E 0./ E 0./ E 0./ E 0./. For ordering information see page A. For technical details see pages L and N.

47 INSULATING CABLE CLAMPS High voltage multipole connectors, as well as a number of connectors containing contact configuration with mixed high voltage and coaxial contacts, are equipped with Polyoxymethylene (Delrin ) collet type cable clamps. The required diameter should be added to the connector part number by selecting the collet diameter according to the cable clamping range under «Cable Dia.» as shown in the following tables. Example: 0 Series pole high voltage plug for use with. mm dia. cable. The part number should be: S 0 A0 /.-UI The cable clamp part number is only required when ordering clamps separately. Material: POM (polyoxy-methylene) Delrin 0 SERIES Cable Diameter Collet Diameter Cable Clamp CONNECTOR TYPES WITH INSULATED CABLE CLAMPS Multipole Multipole with Multipole with High Voltage HT Contact Coax Contact 0 A0 0 A0 0 Z0 0 A0 0 A0 H 0 SERIES Cable Diameter Collet Diameter Cable Clamp Multipole Multipole with Multipole with High Voltage HT Contact Coax Contact 0 A0 0 A00 0 A0 0 Z0 0 Z0 0 A0 0 A0 0 A0 0 A00 0 A 0 A0 0 SERIES Cable Diameter Collet Diameter Cable Clamp Multipole Multipole with Multipole with High Voltage HT Contact Coax Contact 0 A0 0 A0 0 Z0 Insulating clamps for other cable diameters and shapes are available on request. All dimensions shown are in millimeters and are for reference only.

48 CABLE CLAMP SETS FOR WSO WSO Unsealed WSO Sealed Cable clamp Seal Cable clamp Ring Rings H 0 Cable Dia. Clamp Cable Clamp Set Range Diameter Unsealed Sealed. -.. E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. - 0 Cable Dia. Clamp Cable Clamp Set Range Diameter Unsealed Sealed. -.. E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. - 0 Cable Dia. Clamp Cable Clamp Set Range Diameter Unsealed Sealed. -.. E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. - 0 Cable Dia. Clamp Cable Clamp Set Range Diameter Unsealed Sealed E 0./.0 E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./. 0 Cable Dia. Clamp Cable Clamp Set Range Diameter Unsealed Sealed. -.. E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./0.0 E 0./ E 0./0. E 0./0. For ordering information see page A. For technical details see pages L and N.

49 ø CABLE CLAMP SETS FOR WS/WSE WS Spacer for WS 0 - included in clamp set Spacer for WS 0 - P/N 0. { Spacer for WS 0 - P/N 0. No spacer in other series WSE Ring Cable clamp Seal Cable clamp rings for WSE 0 ø 0 Cable Dia. Clamp Cable Clamp Set Range Diameter WS WSE. -.. E 0.0/. E 0./ E 0.0/. E 0./ E 0.0/. E 0./ E 0.0/. E 0./ E 0.0/. E 0./ E 0.0/. E 0./ E 0.0/. 0/0 Cable Dia. Clamp Cable Clamp Set Range Diameter WS WSE. -.. E 0.0/. E 0./ E 0.0/. E 0./ E 0.0/. E 0./ E 0.0/. E 0./ E 0.0/. E 0./ E 0.0/. E 0./ E 0.0/. E 0./ E 0.0/. E 0./ E 0.0/. E 0./ E 0.0/. 0 Cable Dia. Clamp Cable Clamp Set Range Diameter WS WSE E 0.0/.0 E 0./ E 0.0/. E 0./ E 0.0/. E 0./ E 0.0/. E 0./ E 0.0/. E 0./ E 0.0/. E 0./. 0 Cable Dia. Clamp Cable Clamp Set Range Diameter WS WSE. -.. E 0.0/. E 0./ E 0.0/. E 0./ E 0.0/. E 0./ E 0.0/. E 0./ E 0.0/. E 0./ E 0.0/. E 0./ E 0.0/0.0 E 0./ E 0.0/0. E 0./0. 0 Cable Dia. Clamp Cable Clamp Set Range Diameter WS WSE. -.. E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./0. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. 0 Cable Dia. Clamp Cable Clamp Set Range Diameter WS WSE. -.. E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./0. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./. E 0./ E 0./0. E 0./ E 0./. E 0./ E 0./. E 0./. H All dimensions shown are in millimeters and are for reference only. 0 For ordering information see page A. For technical details see pages L and N.

50 PROTECTIVE ELASTOMER SLEEVES ACCESSORIES Material - TPE (Thermoplastic elastomer) J Protective Sleeve for S, SC, SOV Cable Cable Outlet Series Part Number L Outlet Diameter Diameter 0. L = L = Series Part Number L L = L = L = L = L = L = L = L = L = L = L = 0 L = L = 0 L = L = L = 0 L = L = L = 0 L = L = 0 L = 0 L = 0 L = 0 L = Protective Sleeve for K, KE L = 0 L = L = 0 L = L = L = L = L = L = L = L = L = L = L = 0 L = L = L = 0 L = L = L = L = L = L = L = L = These protective sleeves for straight cable plugs and cable receptacles have grooved cable bend reliefs which can be shortened according to cable diameters. The lengths of the protections and the corresponding cable diameters are listed above.

51 ACCESSORIES CLAMP NUT WITH CABLE BEND RELIEF Material: Clamp nut: Nickel and chromium plated brass Bend relief: TPE (Thermoplastic elastomer) Bushing: Nickel plated brass These cable bend reliefs cannot be assembled with the clamp nuts supplied with the standard connectors. Therefore, the cable bend reliefs are supplied as sub-assemblies. 0 SERIES Two types of cable bend reliefs with different diameters are available. For natural chromium plated cable connectors (Standard) Part Number for cable diameter Bend Relief Color E 0.0. E 0.. black E 0.0. E 0.. green E 0.0. E 0.. blue E 0.0. E 0.. yellow E 0.0. E 0.. red E 0.0. E 0.. grey A = 0 L = For black chromium plated cable connectors Part Number for cable diameter Bend Relief Color E 0.. E 0.. black E 0.. E 0.. green E 0.. E 0.. blue E 0.. E 0.. yellow E 0.. E 0.. red E 0.. E 0.. grey J 0 SERIES For natural chromium plated cable connectors (Standard) Part Number for cable diameter E 0.0. E 0.0. E 0.0. E 0.0. E 0.0. E 0.0. E 0.0. Bend Relief Color white black green blue yellow red grey Length D = Cable Dia. A. L L L.0 -. For black chromium plated cable connectors Part Number for cable diameter E 0.. E 0.. E 0.. E 0.. E 0.. E 0.. E 0.. Bend Relief Color white black green blue yellow red grey All dimensions shown are in millimeters and are for reference only.

52 CLAMP NUT WITH CABLE BEND RELIEF ACCESSORIES 0 SERIES For natural chromium plated cable connectors (Standard) For black chromium plated cable connectors Part Number for cable diameter Bend Relief Color Part Number for cable diameter Bend Relief Color E 0.0. E 0.0. E 0.0. E 0.0. E 0.0. E 0.0. E 0.0. white black green blue yellow red grey Length D = Cable Dia. A. L L L.0 -. E 0.. E 0.. E 0.. E 0.. E 0.. E 0.. E 0.. white black green blue yellow red grey IMPORTANT: For WS / WSE 0, use 0 version. J 0 SERIES For natural chromium plated cable connectors (Standard) For black chromium plated cable connectors Part Number for cable diameter Bend Relief Color Part Number for cable diameter Bend Relief Color E 0.0. E 0.0. E 0.0. E 0.0. E 0.0. E 0.0. E 0.0. white black green blue yellow red grey Length D = Cable Dia. A. L L.0 -. L.0 -. E 0.. E 0.. E 0.. E 0.. E 0.. E 0.. E 0.. white black green blue yellow red grey 0 SERIES For natural chromium plated cable connectors (Standard) For black chromium plated cable connectors Part Number for cable diameter Bend Relief Color Part Number for cable diameter Bend Relief Color E 0.0. E 0.0. E 0.0. E 0.0. E 0.0. E 0.0. E 0.0. white black green blue yellow red grey Length D = Cable Dia. A 0. L L. -. L.0 -. L. -0. E 0.. E 0.. E 0.. E 0.. E 0.. E 0.. E 0.. white black green blue yellow red grey

53 ACCESSORIES CONTACT SIZE WIRE GAUGE CONVERSION Crimp style connectors are supplied with the appropriate quantity of crimp contacts. However, replacement contacts may be ordered according to table below. Crimp contacts can be removed from the contact block by means of extraction tools (see page K). Crimp contacts - wire size and tool chart Size Max Wire Series [mm] Polarity (AWG) Crimp Positioner male TX00.0 TX00.00 male TX00.0 TX00.0 female TX00.0 TX00.0 female TX00.0 TX00.0 female TX00.0 TX00. male TX00.0 TX00.0 female TX00.0 TX00.0 female TX00.0 TX00.0 male TX00.0 TX00.0 male TX00.0 TX00.0 female TX00.0 TX00.0 female TX00.0 TX00.0 male TX00.0 TX00. female TX00.0 TX00. male TX00. TX00. female TX00. TX00. J Solder contacts - wire size and conversion table Contact Diameter Contact Maximum Wire Diameter Wire Stranding Sectional Area [mm] [inch] Size [mm] [inch] AWG [mm] [mm ] [inch ] circ. mils () x (/) x () x (/) x () x (/) x () x (/) x () x (/) x () x (/) x () x (/) x (/) x (/) x (/) x (/) x Above mentioned wire diameters may vary slightly depending on connector series and style. Please contact us when the exact cup diameter is required for a specific connector. All dimensions shown are in millimeters and are for reference only.

54 METAL SEALING CAPS ACCESSORIES Sealing Caps for Plugs These metal caps are fitted with an O-ring seal. They protect and seal the mating face of the plugs. Material - Nickel or Black chromium plated brass (ISO CuZnPb) Series O-ring material A FPM FEP FPM 00 FEP FPM 0 00 FEP FPM. 0 FEP FPM 0 0 FEP FPM 0 FEP FPM 00 FEP 00. FPM - VITON Part Number Black Natural mat Plated chrome Plated FEP - TEFLON D Stainless-Steel Cable ø Length Covering material Crimp Ferrule J To attach the ferrule or the crimp lug to the stainless-steel cable, use a crimp tool, a vice or a pair of pliers with parallel jaws Sealing Caps for Receptacles These metal caps are fitted with an O-ring seal. They protect and seal the mating face of the receptacles. Material - Nickel or Black chromium plated brass (ISO CuZnPb) Series Part Number Black Natural mat Plated chrome Plated O-ring material A Crimp Ferrule Crimp Lug NBR 00 FEP NBR 00 FEP NBR 00 FEP NBR. 0 FEP NBR 0 FEP NBR 0 FEP NBR 00 FEP D Stainless-Steel Cable ø Length Covering material NBR - Nitrile FEP - TEFLON Assembled with natural plastic covered stainless steel cable. Assembled with black plastic covered stainless steel cable.

55 ACCESSORIES SPACERS Spacers for WDE Material - Aluminum In order to keep the outer connector diameter as small as possible, the WDE s of 0 and 0 series cannot be totally threaded. Spacers are available to permit mounting on bulkheads thinner than the unthreaded section of the body as indicated by «Emin» of Type on page B. WDE 0 E L Part No WDE 0 E L Part No Spacers for DEE, DEU and DKE Spacers are available for DEE, DEU and DKE to permit mounting on panels thinner than the unthreaded section of the body as shown on page B and on page B0, for the DKE. DEE / DEU / DKE 0 E L Part No E L Part No DEE / DEU / DKE 0 DEE / DEU J DEE / DEU 0 DEE / DEU 0 E L Part No E L Part No Material - Aluminum DEE / DEU 0 E L Part No DEE / DEU 0 E L Part No All dimensions shown are in millimeters and are for reference only.

56 INSULATING / COLOR CODING WASHERS ACCESSORIES Color Coding Washers for connector styles D, DB, DBP, DG, DGP, DK and SF These washers can be mounted between the receptacle flange and the panel. They are used as an identification aid with similar color cable bend reliefs. Material - PVC (polyvinyl chloride) Part Numbers of washers Color white black green blue yellow red grey Series ø D. 0 ø d.0 J The connector style DB 0 requires an inner diameter d = mm The connector style SF 0 requires an inner diameter d = mm Insulating / Color Coding Washers These washers are mounted on both sides of the panel cut-out. They are used to isolate the connector body electrically from the panel, as well as an identification aid with similar color cable bend reliefs. Material 0, 0 Series - ABS (acrylonitrile butadiene-styrene) 0, 0 Series - POM (polyoxymethylene) Delrin Part No ø D ø d ø T A B E E Color For min. max. Material Type white ABS D red ABS D black ABS D white ABS D black ABS D green ABS D blue ABS D yellow ABS D red ABS D grey ABS D black POM D white POM D black POM D black POM DBEE black POM D 0

57 ACCESSORIES GROUNDING WASHERS CABLE CLAMP NUTS Grounding washers for panel connectors d D E Part Number Material - Brass, ISO CuZn Copper and tin plated Locking Washer d D Part Number J Material - Brass, ISO CuZn Copper and tin plated Knurled Clamp Nuts The outside is partially knurled in order to give a good grip to a shrinkable tube, acting as cable bend relief. Part Number Series Natural Black A B D mat chrome Chrome Material - Brass (ISO CuZnPb), Nickel and chromium plated All dimensions shown are in millimeters and are for reference only.

58 MOUNTING NUTS ACCESSORIES Decorative Slotted Nuts Material - Brass (ISO CuZnPb), Nickel and chromium plated Rear-mounted panel receptacles like DBP, DBPC, DBPE, DBPU, DG and DGP are supplied with this type of nuts. Thread Size d E P/N natural P/N black Assembly mat chrome chrome M x TC M x TF00.00 M x TG00.00 M x TK M x TK00.00 M x TP00.0 M 0x TP00.00 M x TR00.00 Decorative Slotted Nuts (DKBE) J Material - Brass (ISO CuZnPb), Nickel and chromium plated These nuts are supplied to all DKBE. Thread Size d E P/N natural P/N black Nut mat chrome chrome aross flats M x M x M x M x M x M x M x Hex Nuts Material - Nickel plated brass (ISO CuZnPb) Hexagon nuts are supplied for all front-mounted connectors, and as rear nut of DG and DGP style bodies. Thread Size E Part Number Nut Assembly across flats M x0. 0. TX00.00 M x0. 0. TX00.0 M x0. 0. TX00.0 M x 0. TX00.0 M x 0.0 TX00.0 M x 0. TX00.0 M x 0. TX00.0 M x 0. TX00.0 M 0x 0. TX00.0 Nut types for 0, 0 and 0 series see below. Slotted Nuts Slotted nuts are supplied with all panel mounted connectors of the 0, 0 and 0 series. Thread Size d E Part Number Assembly M x 0. M x 0 0. TX00.0 M x 0. TX00.0 M 0x 0. TX00.0 M x 0. TX00.0 M x 0 0. TX00.0 M x 0. TX00.0 Material - Nickel plated brass (ISO CuZnPb)

59 ASSEMBLY TOOLS SPANNERS / WRENCHES Double-End Open Spanners Extra thin Material - Chrome Alloy Steel, Chrome plated Fork Angles - and Opening Across Flats Length Fork Thickness Part Number.0 TX TX TX TX TX TX TX TX TX00.0 Open-End Spanners Extra thin Material - Chrome Vanadium Steel, Chrome plated Fork Angle - Opening Length Fork Across Flats Thickness Part Number. TX TX TX TX00.0. TX TX TX TX TX00.0 Hook Spanners For side slotted nuts K Thread Size Nut Outer Diameter Part Number M x 0 - TX00.0 M 0 x M x - TX00.0 M x M x - TX00.0 Material - Hardened Steel, Gunmetal finish Nutdriver with T-Handle and Hex Drive For decorative slotted nuts Material - Hardened Steel, Nickel plated Thread Nut Outer D Hex Part Size Diameter Drive Number M x 0. TC M x 0 TF00.00 M x 0 TG00.00 M x TK M x 0 TK00.00 M x TP00.0 M 0 x TP00.00 M x TR00.00 All dimensions shown are in millimeters and are for reference only.

60 CRIMPING TOOLS ASSEMBLY TOOLS Crimp ULTRA PRECISION for closed C crimp termination Contact Dia. C Crimp Part Number BALMAR or DANIELS MH - 00 TX00.0. BUCHANAN 0 TX00. Standards IEC 00 / DIN, Part MIL-C-0, Class I, Type The best choice of precision crimp tools for highly reliable eight indenter crimping per US-MIL, IEC and DIN Specifications. Positioners have to be ordered according to contact. Positioner FISCHER For crimp tool TX00.0 For crimp tool TX00. For the choice of Fischer positioner, please refer to page J. K Crimp for coaxial cable Part Number TX00. - ERMA 00 Precision crimp tool without dies for hexagon and square crimping. A light weight tool with handle span of only 0 mm. Weight (without dies): 0. kg Standards MIL-C-0, Class I, Type For crimping dies not larger than. mm across flats. Maximum crimping dies: IEC 00-G; BSI size G. Crimping Dies for precision crimp tool P/N TX00. TX00.0 Special crimping dies for coaxial cables of cable group (RG- etc.). The hexagon corresponds to IEC 00-B. TX00. Special crimping dies for coaxial cables of cable group (RG- etc.). The hexagon corresponds to IEC 00-D. HEXAGON CRIMP for coaxial cables Table of cable groups see page Q

61 ASSEMBLY TOOLS TOOLS FOR CRIMP CONTACTS AND HIGH VOLTAGE CONTACTS Contact Insertion Contact Dia. Part Number 0. TX TX TX00.. TX00. for inserting male and female removable, crimp contacts into the contact block. Material - Handle: POM (black Delrin ) Fork: Steel, chrome plated Especially recommended for small gauge and fragile wires. Contact Extraction Contact Dia. Part Number Coax Insert No Part Number 0. TX TX TX00.0. TX00.. TX00.0 E 00. E 00. E 00. E 00. E 00. TX00. TX00. Material - Housing and Plunger: Sleeve: Slide: POM (black Delrin ) Stainless Steel Steel for extracting male and female removable, crimp contacts from the contact block. The sleeve of this tool is pushed over the contact, thereby releasing the contact retaining mechanism. The tool plunger is then pushed to eject the contact. Assembly for male contacts with outside thread TP00.00 for special, male contacts (e.g. contact P/N E 00.) which are inserted only after termination to a wire. Slip tool through the contact mounting hole from the mating side of the contact block. Screw the tool onto the terminated contact and pull firmly until the contact is locked into the contact block. Attention: Once contact P/N E 00. has been inserted into the contact block, it cannot be removed. K Length: mm Inside thread: M Material: Stainless Steel Assembly for female contacts with inside thread TP for special, female contacts (e.g. contact P/N E 00.) which are inserted only after termination to a wire. Slip tool through the contact mounting hole from the mating side of the contact block. Screw the tool into the terminated contact and pull firmly until the contact is locked into the contact block. Attention: Once contact P/N E 00. has been inserted into the contact block, it cannot be removed. Length: mm Outside thread: M. Material: Stainless Steel All dimensions shown are in millimeters and are for reference only.

62 QUALITY MANAGEMENT-CERTIFICATE ENVIRONMENTAL MANAGEMENT-CERTIFICATE SN EN ISO 00:000 L SN EN ISO 00:

63 TECHNICAL INFORMATION D C B A F E A Tapered sleeve B Latching sleeve C Plug body D Clamp nut E Latching groove F Receptacle shell L The values given in this catalogue are measured under standard environmental conditions. They shall not be translated for other applications without previous examination of the corresponding standards. Please also observe the local environmental regulations. Some connectors shown herein are intended for use in areas of high frequencies and high voltages. Suitable safety precautions should be taken to ensure that people do not come into contact with powered conductors during installation and operation. Every effort has been made to ensure that this catalogue is accurate at the time of printing. Fischer Connectors reserves the right to make any modification according to the state of the art without notice and without obligation to replace or manufacture obsolete items. All dimensions shown are in millimeters and are for reference only.

64 TECHNICAL INFORMATION FISCHER Automatic Latching - How it Works The drawing shows the longitudinal section of a receptacle and a plug in the unmated position. The latching sleeve of the plug has a fixed amount of lengthwise play along the body. The flexible fingers which extend from this sleeve possess bevelled protrusions. When the connectors are mated, these protrusions are firmly captivated by the receptacle's internal latching groove. L If the attached cable or clamp nut is pulled, the tapered sleeve is forced under the sliding sleeve, holding the fingers even more tightly into the receptacle s latching groove. The more the cable or connector body is pulled, the more the locking pressure increases. Pulling lengthwise on the plug s latching sleeve unmates the connectors by allowing the fingers to deflect free of the latching groove. All FISCHER connectors contain this reliable, patented self-latching feature. However, non-latching cable plugs are provided under the designation «SOV» and «SOVE». Panel plugs «SF» and «SFE» are non-latching by design.

65 TECHNICAL INFORMATION Contact Protection, Type «A» and «Z» To protect users from contact with dangerous voltages, most FISCHER connectors exist in two versions; the standard type «A» and the inverted type «Z». Type «A» Standard The contacts of the receptacle are protected against accidental touch. This version is recommended when voltage is present on the receptacle. Type «Z» The contacts of the plug are protected against accidental touch. This version is recommended when voltage is present on the plug. Receptacle «D» Plug «S» IMPORTANT An «A» type connector can never be mated with a «Z» type connector. The letter code before the series number always determines the type of housing. A plug «S» has the same housing in type «A» as in type «Z», but type «A» comes with unprotected contacts while type «Z» is equipped with touch-protected contacts. In most cases these are female contacts which are recessed in the insulator. For the exceptions see «High Voltage Connectors» in section C. Bulkhead Feed-through WDE Type «AZ» is the standard version of the WDE. The flange side accepts an «A» type plug, and the threaded side accepts a «Z» type plug. Type «Z» plug (S) WDE, type «AZ» Type «A» plug (S) L The «ZA» version of the WDE accepts a type «Z» plug at the flange side and accepts a type «A» plug at the threaded end. Connector Keying and Orientation Code (Standard) Orientation during mating is achieved by means of arc-shaped metal guides which ensure exact polarization of the connectors. This highly reliable design prevents any contact damage caused by miskeying. Code Receptacle Plug In order to avoid mismating with connectors of the same type, the arc-shaped guides are available with a differently shaped pattern as Code. For availability of this and other keying options please contact us. This self alignment when mating does not necessarily require guide marks on the connectors. However, most connectors are available with a guide mark if desired. Standard colors are red for natural chromium-plated housings and white for black chromium-plated housings. For further differentiation, we recommend the colored cable bend reliefs combined with coding washers, available in the same colors. These items are listed under «Accessories» in section J. All dimensions shown are in millimeters and are for reference only.

66 TECHNICAL INFORMATION FISCHER Contacts The FISCHER contact design is highly reliable. It features a very low and constant contact resistance, tested to more than 000 mating cycles. These outstanding results are based on the following design features: Closed and bevelled contact entrance prevents deformation of spring surfaces. Four 0 offset spring loaded lamellas guarantee superb wiping contact with the male pin. The contact force is 00% checked by microprocessor-controlled automatic testers. This is important because the service life depends more on the contact force than on the thickness of the gold plating. All contacts are screw machined. Standard female contacts are fabricated from special spring bronze (ISO CuSnPbZn, ASTM C00). The terminations of the standard crimp contacts are selectively soft-annealed. A hard, homogeneous gold is plated over a smooth nickel layer. The standard surface treatment of the contact pins and sockets consists of µm gold according to MIL-G-0 type I, class on top of µm nickel according to QQ-N-0, class, measured on the functional surfaces. Other plating types and thicknesses are available. Types of Contact Terminations The tables of «Electrical Specifications» show the available types of terminations. Most multipole contact configurations of series 0 through 0 can also be supplied with termination for printed circuits. The pins of these contacts are undercut to a diameter of 0. mm (0.0 in) with some exceptions to 0. mm (0.0 in). L Crimp contacts are also available and come in various sizes suitable for a variety of wire gauges. A complete summary including the AWG range is listed under «Accessories» and crimping tools are listed under «Assembly s». For large quantity users, the crimp termination technique offers certain advantages. Frequently, faster assembly is possible using less skilled labor. Another advantage lies in the ability to replace contacts. For all connector insulators we use high quality engineering plastic material. However, Teflon (PTFE) insulators are not used for crimp connector as its relative softness will not reliably retain the crimp style contacts. The quality of a crimp connection depends primarily on the permanent deformation of the crimp barrel and the consistently reproducible crimp force. Our crimp contacts undergo a selective high-frequency annealing process in order to soften the bronze in the crimp area only. Naturally, only proven, high precision crimp tools should be used. We offer a full line for your convenience. For FISCHER multipole connectors, we suggest that you use only the closed, crimp indenter according to MIL-C-0, class I, type, which guarantees a gas tight crimp as long as the tool is properly adjusted. Coaxial connectors are also available with crimp contacts, but the center contact can be square crimped. The cable shield can be hex crimped, both according to MIL-C-0, class I, type.

67 TECHNICAL INFORMATION Cable Clamp Sets FISCHER connectors provides a robust and reliable system for ensuring excellent cable retention and strain relief. A collet style clamp system is used to retain the cable over a relatively large jacket surface area. This prevents damage to small diameter and delicate conductors. The following list describes the different types of clamp systems available. Type «S» Type «U» Type «E» For Shielded cable, when the shield is to be terminated to the connector body. Shielded clamps can also be used for unshielded cable.. For Unshielded cable, or where the shield is not to be terminated to the connector body. These clamps are available for series 0 through 0 and are slightly easier to assemble as there is only one piece instead of three. For both shielded and unshielded cables, where the interface between cable and connector body must be sealed. For WS, WSE and WSO Cable clamp sets for right-angle connectors listed on page H and H0. For all body styles with mixed contacts: Type «UI» One piece, insulating collet type clamps made of POM (DELRIN ) are required for mixed coax and high voltage connectors of series 0 through 0, listed on page H. Coaxial connectors require the type «S» clamps for non-sealed connectors and the type «E» clamps for sealed connectors. The collet diameter has to be selected from the appropriate tables on pages H - H to complete the connector part number. To promote maximum reliability, the FISCHER cable clamp system requires that it be properly sized to the jacket diameter of the cable. Therefore, it is very important that the cable diameter and its tolerances are accurately known when specifying the appropriate clamp set. If in doubt about choosing the correct cable clamp, please contact us. Multipole connectors of series 0-0 are delivered with shipping spacer in lieu of the clamp set. The required cable clamp sets are ordered separately and are supplied in plastic tubes. During assembly, the spacer is replaced by the clamp set. This accelerates cable termination and also reduces inventory for those customers requiring multiple clamp sizes. To select cable clamp sets, see available diameters in section H and ordering information on page A. Materials and Surface Treatment The standard FISCHER connector shells are nickel plated brass with a natural matte chrome finish. Black chrome finish is available as an option. See table of Standardized Suffixes on page A. L Internal piece parts are nickel plated brass. When warranted by an extreme environment, in most cases type L stainless steel can be substituted for all metal parts. Material Coating Piece Parts Designation ISO Standards Finish US Standards Shell (Housing) Clamp nut Brass CuZnPb Decorative slotted nut - µm Ni SAE-AMS-QQ-N µm Cr SAE-AMS-QQ-N-0 Plug body Cable clamp Inner Sleeve Brass CuZnPb > µm chemical Ni MIL-C-0E classe Spacers and Rings Nuts and Washers Male contacts Brass CuZnPb - µm Ni AMS D Male crimp contacts Bronze CuSnPbZn + µm Au ASTM B Female contacts Bronze CuSnPbZn (MIL-G-0 type I) Other materials and surface treatments are available on request. All dimensions shown are in millimeters and are for reference only.

68 TECHNICAL INFORMATION Insulating Materials Contact blocs and other insulators for our standard connectors are manufactured from high performance engineering plastic materials. The standard materials of each connector series are listed under «Electrical Specifications» in section D through F. Ceramics and other dielectrics are available on special order. In the following reference list we also included POM (Delrin ), which is mainly used for sealing accessories and insulating cable clamps, but not as contact bloc material. International Symbol Chemical Name Trade Name PAI Polyamide-imide Torlon PBT Polybutylene-terephthalate Celanex, Valox, Crastin, Ultradur,... PEEK Polyether-etherketone PEEK PTFE Polytetra-fluorethylene Teflon, Hostaflon,... POM Polyoxy-methylene Delrin, Hostaform, Celcon,... The following chart shows characteristic values of these engineering plastic materials. L Characteristics Standards Unit of ASTM Internat. DIN Measure PAI PBT PEEK PTFE Volume resistivity D- IEC Ω cm 0 > 0 > 0 0 Dielectric strength ( mm sample) D- IEC kv/mm 0 Dielectric constant at 0 khz D-0 IEC Dielectric loss tangent at MHz D-0 IEC Tensile strength D- ISO R N/mm Flexural strenght at C D-0 ISO R N/mm 0 00 no breakage Flexural modulus at C D-0 ISO R kn/mm Maximum continuous temperature UL- 0 C Flammability rating ( mm sample) D- UL- V-0 V-0 V-0 V-0 Limiting oxygen index, LOI D- ISO % O Moisture absorption, hrs at C D-0 ISO RA % Steam sterilization limited limited very good very good Ionizing radiation resistance Co0 Rad Natural color / other color greenish (black) gray-beige white N/mm = MPa = 0. kg/cm kn/mm = GPa = 0 kg/mm 00 Rad = Gy (Gray) = J/kg These typical values are based on manufacturers data. The use of connectors under certain environmental conditions requires specific tests that take into consideration all the specifications of all the materials used. FISCHER's own experimental values to be taken as a guide only. ASTM DIN IEC ISO UL American Society for Testing Material Deutsches Institut für Normung Internationale Elektrotechnische Kommission Internationale Organisation für Standardisation Underwriters Laboratories

69 TECHNICAL INFORMATION Elastomer Seals Sealed connectors are fitted with O-rings and cable sealing gaskets. For O-rings, the standard material are: Viton for O-rings TPE (Thermoplastic Elastomers) for cable sealings, protective sleeves and strain reliefs. Please note that as an elastomer reaches its lower temperature limit, it becomes rigid and loses the flexibility required for connector mating and unmating. If sealed connectors have to be manipulated at low temperatures, the O-ring in the mating area has to be of a material with a considerably lower temperature limit. The elastomers listed below represent presently available materials, which FISCHER can substitute when required by an application. Not all materials are available in all shapes and sizes so please check with us for details. Compound and Trade Name Chemical Name Temperature Range (ASTM D-) Excellent resistance to NBR BUNA N Acrylonitrile- Butadiene rubber -0 C to +0 C Weather, ozone, fuels, oils NBR per Acrylonitrile- Weather, ozone, fuels, mineral oil based - C to + C MIL-P- Butadiene rubber hydraulic fluids, Military applications FPM (VITON) Fluoro Elastomer -0 C to +00 C Acids, weather, ozone, fuels, mineral and Silicone oils, high vaccum, gamma rays CR Polychloroprene Alcohol, ammonia, chlorine, ozone, FREON, -0 C to +00 C (NEOPRENE) Elastomer soda, vegetable and Silicone oils EPDM, Ethylene-Propylene Alcohol, weather, hot water, vapour, -0 C to +0 C EPM or EPR Diene Elastomer brake fluids, detergents, gamma rays TPE-S, TPE-O Styrene-Ethylene- Very resistant, except to aromated and -0 C to +0 C (Thermoplastic Elastomer) Butadiene-Styrene chlorinated hydrocarbons Operating Temperatures L The temperature ranges quoted by the manufacturers of the plastic materials are usually the absolute maximum values. When exposed to the mechanical and electrical stresses present in a connector, these values are often unrealistic. If a composite connector system including accessories is used, then the item with the lowest temperature performance will dictate the operating temperature limit of the system. Listed below are our recommended operating temperature ranges: Standard plugs and receptacles Operating Temperature Limits Long Term Short Term Contact block of PAI and PEEK - C to +00 C +0 C Contact block of PTFE - C to +0 C + C Contact block of PBT - C to + C +0 C Connectors with sealed cable clamp - C to + C + C Receptacles DEE, DEU, DBEE, DBEU, DBPE, DBPU, WDE - C to + C + C DELRIN (POM) accessories -0 C to +00 C -0 C to +0 C For lower temperature ranges see «Elastomer Seals» on this page. All dimensions shown are in millimeters and are for reference only.

70 TECHNICAL INFORMATION Operating Voltages (Rated Voltage) The test voltages (dielectric withstanding voltage) listed under «Electrical Specifications» are readings measured in our laboratory according to IEC 0-, test a (Voltage proof). This standard is equivalent to the German DIN 0, section as well as to US standards MIL-STD-0, method 0 and MIL-STD-, method 00. The test results can also be related to the British Standard BS 0, paragraph... (Voltage proof). All tests are carried out under standard temperature and pressure. All other conditions require the appropriate derating factors in conformance to the applicable standards. If no other restrictive standards or local environmental regulations are to be applied, we recommend the calculation of the rated voltages according to IEC 00-, also specified in BS 0, paragraph... (c). For connectors up to kv rated voltage, this method of calculation also corresponds to the recommendation of MIL-STD-, method 00. Connectors for rated voltages up to and including kv: Operating voltage = Test voltage Connectors for rated voltages higher than kv: with minimum test voltage of 00 V Operating voltage = Test voltage with minimum test voltage of kv. IEC 0 : Standard of the International Electrotechnical Commission: «Electromechanical components for electronic equipment» IEC 00 : Includes connectors for frequencies below MHz. BS 0 : British Standard Specification for Electrical connectors of assessed quality for d.c. and low frequency application. Current Rating (Maximum admissible current) The current-carrying capacities, listed under «Electrical Specifications» were calculated in our test laboratory according to IEC 0-, test a (Temperature rise) and b (Current - temperature derating), equivalent to DIN 0, sections and. The preferred values in these standards are 0 C, 0 C and 0 C temperature rise above the ambient temperature. While cable manufacturers specify the maximum admissible current at 0 C, some manufacturers of connectors specify the values at 0 C temperature rise. We list both values in our catalogue. When selecting a connector, attention must be paid to the fact that the temperature rise caused by current must be added to the ambient temperature and that the resulting value may not exceed the upper component limit, listed under «Operating Temperatures» on page L. In the picture below, the corrected derating curve shows that the current must approach zero when the upper component temperature limit has been reached. L Current carrying capacity Upper current limit (set by the chosen temperature rise) Base curve Corrected curve Upper component temperature limit Permissible operating range Current capacity (derating curve) Ambient temperature The values of the maximum admissible current, listed under «Electrical Specifications», are valid for each contact, wired with the largest possible conductor cross-section. For coaxial and triaxial connectors, the current is valid for the center and the outer contact. Depending on the conductor cross-section, single contacts can carry a higher current if remaining contacts carry correspondingly lesser loads. As general guideline a single contact can carry twice the current value indicated in our tables. Due to the measuring method, cable heating has a considerable influence on the connector current capacity. Please contact us if you require more detailed information. For voltage and current ratings of right angle plugs «WS, WSE, WSO» and bulkhead feedthroughs «WDE», please consult us.

71 TECHNICAL INFORMATION HERMETICALLY SEALED AND PRESSURE TIGHT CONNECTORS Hermetically sealed and pressure-tight connectors are one of our specialties. Based on decades of experience, we can deliver almost any type of connector in a hermetically sealed version. Please note that our sealed and unsealed connectors have identically dimensioned mating areas and thus are intermateable. Distinction must be made between liquidtight and gastight connectors limiting the gas-tightness to fixed connectors (receptacles and panel plugs) and their mounting areas. IEC 0, BS 0 and DIN 0 00 standards classify the degree of «Ingress Protection» (IP), from water (dripping water, splashed water, streaming water and continuous immersion) as well as protection from dust. Our range of liquidtight connectors includes styles like DEU, DBEU, DBPU and similar. Liquidtight connectors are rated IP to a depth m in water. Hermetically sealed connectors are gastight. Therefore they exceed the IP rating (which is a definition limited to liquids). Hermetically sealed connectors can be used under water to a depth of 0 meters (or more with protective covers. However specific testy is then required) The sealing material limits the working temperature range to approximately - C to + C. We highly recommend that the application falls within these limits. If not, please check with us about using special materials. FISCHER connectors are sealed in the following fashion: (refer to the illustrations on page M): a b c d DEE, DBEE, DBPE, SFE and WDE DEE, DBEE, DBPE, DKE, DKBE, SFE and WDE All receptacles and cable receptacles S, SC, SV, SOV, WSE WSO, DKE, DKBE and KE Sealing mechanism Sealing technology Connectors are sealed even unmated Proprietary or unprotected. Glass epoxy composite material Gastight contact insulation + O-ring seal * Panel seal O-ring seal * Sealing of two connectors O-ring seal * when mated Sealing of cable clamp Elastomer sealing ring adjusted to cable ø e DEU, DBEU, DBPU Liquidtigth sealing even High performance unmated or unprotected potting resin * O-ring seals made of VITON are standard. Other elastomers are available on request. M The IEC standard defines the gas-tightness of connectors in terms of leakage rates ranging between a few mm /hr. and a few cm /hr. The MIL-C- (USAF) requires in class Y a leakage rate which at a pressure differential of atmosphere does not exceed the value of 0. mm /hr. ( 0.0 µft /hr.). Our hermetically sealed connectors meet all requirements of the relevant standards. At the highest sealing level, the leakage rate is between 0.00 and 0.0 mm /hour. The leakage rate of our sealed connectors is therefore much lower than required by the US MIL Standards and exceeds the IEC Standards by a factor 00. Prior to shipment, all hermetically sealed receptacles, panel plugs and feed-through connectors are subject to a vacuum test. Helium is used as a tracer gas, and this non-destructive test is carried out similarly to MIL STD, Method 00B, and IEC standards 00-- Test Qk: «Sealing tracer gas method with mass spectrometer» (Test method, Alternative b). In this test, the vacuum chamber is sealed by the test connector and the spectrometer shows the leakage rate directly. FISCHER tests for less than 0 - mbar l/s or, according to SI-System, 0 - Pa cm /s. If needed, the residual leakage can be tested for values 0 - mbar l/s or 0 - Pa cm /s. All panel connectors, with the exception of a few coaxial and high voltage connectors, are available in hermetically sealed versions.

72 TECHNICAL INFORMATION HERMETICALLY SEALED CONNECTORS Fixed connectors Free connectors a DEE S c b c d DBEE WSE WSO d DBPE b c d SFE KE M DEU DEU / DBEU / DBPU IP Sealed panel receptacles For application where no deep water or hermetic performance is needed, new styles, like DEU, DBEU and DBPU, are available. e Having identical external dimensions as the hermetic receptacles, these styles, do not contain an O-ring seal between insulator and shell. Therefore, the styles DEU, DBEU and DBPU have a rating of IP, even without a mated plug. Those styles meet IP at an immersion m DKE b d c DKE / DKBE Cable receptacles with sealed cable clamp The DKE, DKBE are sealed at points b, c and d. However, they are only sealed when mated with a plug S with a sealed cable clamp or a sealing cap. DKBE To meet the sealing requirements at point d, the proper size of the cable clamp set must be selected to fit properly with the cable. For effective sealing, the cable jacket must also be cylindrical and smooth. d b c

73 TECHNICAL INFORMATION b WDE a c Type «AZ» is the standard version of the WDE. The flange side mates with an «A» type plug, and the threaded side mates with a «Z» type plug. In the inverted type «ZA» of the WDE the contact block is mounted in the opposite direction. Therefore it mates with a type «Z» plug at the flange side and with a type «A» plug at the threaded end (see also page L). While both sides of the WDE are equipped for self-latching, only the flange side contains a sealing O-ring in the mating area. Whether sealed plugs must be used depends on the application. Sealed plug are not required when the connectors are not exposed to environmental conditions requiring protection. Fixed connectors The fixed connector types DEE, DBEE, DBPE, SFE and WDE meet all requirements for sealing at points a, b and c listed on page M. They are hermetically sealed even in unmated position, whether mounted or not. However, proper mounting in a bulkhead with a smooth and flat surface is a prerequisite for proper sealing to an enclosure. Free connectors The plugs S and WSO are sealed at points c and d, page M, but the sealing is only effective when connected to a connector with interface o-ring c. To seal properly at d, the cable diameter must match the cable collet and sealing ring. The cable jacket must also be cylindrical and smooth. Protective covers for sealing of unmated, free connectors are available and come complete with an O-ring seal. However, if the contacts must also remain accessible for steam or chemical sterilization, the connector must be potted with an elastomer such as silicone elastomer in order to avoid liquid or steam penetration. For the sealed cable receptacles KE, DKE and DKBE, the same conditions apply as described above for S and WSO. M Pressure Pressure Differentials Our standard hermetically sealed, fixed connectors will withstand a pressure differential of at least bars, or 0. MPa according to SI-System. However, a greater differential can be obtained if the higher pressure is on the side of the receptacle. In order to determine the highest possible pressure for a particular type of connector, please contact us. Solder side Mating side

74 TECHNICAL INFORMATION General Environmental Protection In many applications where only a protection against dust or liquid splash is required, an unsealed connector shrouded with a flexible protective sleeve will perform effectively. Additionally, connectors can be protected with sealing caps while unmated. Protective sleeves and caps are also very effective in preventing dirt, mud or other foreign matter from fouling, shorting, or damaging the contacts. Mechanical damage from impact on hard surfaces can also be minimized with the use of this accessories. The following plug types are suitable for use with protective sleeves: S Locking plug } SC Clic-Loc plug SOV Non-locking plug listed under «Accessories» on page J. K Cable receptacle KE Sealed cable receptacle Front projecting receptacles DB, DBEE or DBEU and plug with protective sleeve The front end of the plug s protective sleeve encloses the projecting portion of the receptacle DB, DBEE, DBEU. Plug and cable receptacle K or KE, both with protective sleeves The front end of the plug s protective sleeves encloses the front of the receptacle K or KE. M Bulk-head feedthrough WDE and plug with protective sleeve The front end of the protective sleeve encloses the projecting portion of the WDE. The combination is only possible for WDE Series 0, 0 and 0 (Type, page B). Panel mounted cable receptacle DKE, DKBE and plug with protective sleeve The front end of the protective sleeve encloses the projecting portion of the DKE and DKBE. The combination is only possible for DKE, DKBE Series 0, 0, 0 and 0. Tamper-proof plugs SV and SA cannot be equipped with protective sleeves.

75 GENERAL CABLE ASSEMBLY INSTRUCTIONS. Remove shipping retainer (PS) and contact block SEALED VERSION UNSEALED VERSION. Slide piece parts over the cable (possibly with parts in plastic tube) Unshielded clamp Shielded clamp Plastic tube (BDS) with cap (PE) Shrinkable tubes for better terminal insulation. Strip cable and wire according to pages O and P. Fit wire into contact barrel and crimp (s see pages O and P) '. Strip cable and wires according to pages O and P '. Tinning of strands recommended C R I M P C O N T A C T S S O L D E R C O N T A C T S Extraction tool for contact replacement. Insert contacts into insulator and push them home by means of insertion tool (contact numbering see pages P) Solder Iron '. Solder each wire to the corresponding contact (contact numbering see pages P) CLIC! Pull shrinkable tubes over contact terminals and shrink Half shell Ring Half shell Screen Washer N Ring Seal Clamp nut Clamp. Slide the ring to the front end. Bend cable screen outwards. Insert half shell and retain with the ring. Slide washer, seal and clamp against the ring and retain the screen between ring and washer Body 0. Trim protruding screen strands Guides. Screw clamp nut to the body and tighten by means of wrenches (see pages O and P). Push the cable assembly into the body, orienting the guides to the slots Clamp nut The assembly is now finished. All dimensions shown are in millimeters and are for reference only.

76 MOUNTING INSTRUCTION Panel Cut-Out Type Type Type Type Body Style SF SFE D DEE, DEU DB DBEE, DBEU DBP DBPC DBPE DBPU DG DGP WDE DK DKBE DKE Type A B Type A B Type A B Type A B Type A B Type A B Type A B Standard Tolerances ISO - - DIN -f - SN 0-f Dimensions [mm] >... 0 > > N General tolerances (fine) ± 0.0 ± 0. ± 0. ± 0. Orientation of mounting flats to guide sleeve position. Connectors with standard code Connectors are here seen from the front side which is the mating face. The orientations of the contact blocks to the arcshaped guides are shown in section P, but always from the wiring side. The following rules are only valid for standard versions. Other orientations of guides and/or guide marks may exist as special options.. Fixed Connectors for cut-out according to Type All connector types «A» and «Z» for D-hole mounting per Type above have the arc-shaped guide on the left side when the mounting flat is in the o clock position. A standard connector mounted in this hole will have its guide mark at the o clock position. Flat Metal guide Guide mark Contact block. Fixed Connectors for cut-out according to Type All above shown connector types «A» and «Z» for double-d hole mounting per Type above, have the arc-shaped guide oriented in parallel to the two flats. A standard connector mounted in this hole will have its guide mark at the o clock position when the arc-shaped guide is placed to the left side of the connector.. Connectors with special code See «Connector Keying and Orientation» on page L. Please refer to drawings of these special connectors. Flat Metal guide Guide mark Flat Contact block

77 NUT TIGHTENNING TORQUE VALUES Recommended nut tightening torque values [Nm] Body Style S, SA, SC, SOV, SV SF SFE...0. WS, WSE, WSO D, DBP, DG, DGP DEE, DEU DB....0 DBEE, DBEU DBPE, DBPU DKBE WDE...0. K, KE DK DKE The quality of the front panel surface under the nut as well as the caracteristics of the cable sheath may indfluence the values. Tests have to be made to evaluate exact values. The first value in this zone corresponds to the tightening torque value for the cable clamp nut. N Recommendation: To secure the cable clamp nut, we recommended the use of threadlocking adhesive. All dimensions shown are in millimeters and are for reference only.

78 CABLE ASSEMBLY INSTRUCTIONS COAXIAL COAX SERIES 0 Cable Clamp * Crimping A) Positioner B) Crimp Dies Insertion Extraction Wrench Size Wrench Size Torque REFERENCE NUMBER A B C P /N P/N P/N P/N [Nm] 0 A00 S 0. E 0. 0 A00 S. 0. E A0 S Z0 E 0. 0 A0 S Z0 B 0 A0 0 Z0 S. TX00. TX00. RG ( cable ) O * S - Shielded cable clamp E - Sealed cable clamp All specifications are typical and have to be adjusted according to the cable construction and dimensions. For details see page L.

79 COAXIAL CABLE ASSEMBLY INSTRUCTIONS COAX SERIES 0 0 REFERENCE NUMBER 0 Cable Clamp * A B C Crimping A) Positioner B) Crimp Dies Insertion Extraction P/N P/N P/N P/N Wrench Size Wrench Size Torque [Nm] 0 A00 S Z00 E A00 S Z00 E A0 S Z0 E A0 S E A00 S... E. 0 A00 S 0 Z00 E 0 A0 0 Z0 S E 0 S. E. O 0 A00 S 0 Z00 E 0 A0- S. 0 Z0- * S - Shielded cable clamp E - Sealed cable clamp All specifications are typical and have to be adjusted according to the cable construction and dimensions. For details see page L. All dimensions shown are in millimeters and are for reference only.

80 CABLE ASSEMBLY INSTRUCTIONS COAXIAL COAX SERIES 0 0 Cable Clamp * REFERENCE NUMBER A B C 0 Crimping A) Positioner B) Crimp Dies Insertion Extraction P /N P/N P/N P/N Wrench Size Wrench Size Torque [Nm] 0 A00 S. 0 Z00 E. 0 A00 S. E. 0 A00 S. 0 Z00 E. 0 A00 S. 0 Z00 E. Contact assembly tool: 0 A0 S 0 D 0 A0 TP Z0 S 0 Z0 TP A0 Contact assembly tool: S S 0 A0 TP D 0 A0 TP O 0 A00 S Z00 E A00 S A0 0 Z0 S E 0 0 S E 0 0 * S - Shielded cable clamp E - Sealed cable clamp All specifications are typical and have to be adjusted according to the cable construction and dimensions. For details see page L.

81 TRIAXIAL CABLE ASSEMBLY INSTRUCTIONS TRIAX SERIES REFERENCE NUMBER 0 Cable Clamp * A B C D Crimping A) Positioner B) Crimp Dies Insertion Extraction P /N P/N P/N P/N Wrench Size Wrench Size Torque [Nm] 0 A00 S A0 S.. 0. E A0 S.. 0. E A0 S E O * S - Shielded cable clamp E - Sealed cable clamp All specifications are typical and have to be adjusted according to the cable construction and dimensions. For details see page L. All dimensions shown are in millimeters and are for reference only.

82 CABLE ASSEMBLY INSTRUCTIONS MULTIPOLE P Torque Wrench Size Wrench Size Extraction Insertion Positioner Crimping Cable Clamp * SERIES 0 [Nm] P / N P / N P / N P / N L B C Number of Contacts plug receptacle plug receptacle Type «A» REFERENCE Type «Z» NUMBER S. 0. U 0. E 0. 0 A0 0 Z0 S. 0. U 0. E 0. 0 A0 0 Z0 S. 0. U 0. E 0. 0 A0 0 Z0 U TX00.0 TX00.0 TX S 0 A0 K 0 Z0 crimp U TX00.0 TX00.0 TX S 0 Z0 K 0 A0 see page J All specifications are typical and have to be adjusted according to * S - Shielded cable clamp the cable construction and dimensions. U - Unshielded cable clamp E - Sealed cable clamp For details see page L

83 L B C MULTIPOLE CABLE ASSEMBLY INSTRUCTIONS Torque Wrench Size Wrench Size Extraction Insertion Positioner Crimping Cable Clamp * SERIES 0 [Nm] P / N P / N P / N P / N Number of Contacts plug receptacle plug receptacle Type «A» REFERENCE Type «Z» NUMBER S. 0. U 0. E 0. 0 A0 0 Z0 U TX00.0 TX00.0 TX S 0 A0 K 0 Z0 crimp U TX00.0 TX00.0 TX S 0 Z0 K 0 A0 crimp.. 0. S U A0 0 Z0 0. E 0. U. TX00.0 TX00. TX A0 0 Z0 crimp see page J All specifications are typical and have to be adjusted according to * S - Shielded cable clamp the cable construction and dimensions. U - Unshielded cable clamp E - Sealed cable clamp For details see page L P All dimensions shown are in millimeters and are for reference only.

84 CABLE ASSEMBLY INSTRUCTIONS MULTIPOLE P Torque Wrench Size Wrench Size Extraction Insertion Positioner Crimping Cable Clamp * SERIES 0 [Nm] P / N P / N P / N P / N L B C Number of Contacts plug receptacle plug receptacle Type «A» REFERENCE Type «Z» NUMBER S U E A0 0 Z0 S U E A0 0 Z0 S U E A0 0 Z0 S U E A0 0 Z0 S U E A0 0 Z0 S.. TX00.0 TX00.0 TX U. TX00.0 TX00.0 TX E. TX00.0 TX00.0 TX A0 0 Z0 crimp see page J All specifications are typical and have to be adjusted according to * S - Shielded cable clamp the cable construction and dimensions. U - Unshielded cable clamp E - Sealed cable clamp For details see page L

85 L B C S U E S.. TX00.0 TX00.0 TX U TX00.0 TX00.0 TX E. TX00.0 TX00.0 TX S U E S MULTIPOLE CABLE ASSEMBLY INSTRUCTIONS Torque Wrench Size Wrench Size Extraction Insertion Positioner Crimping Cable Clamp * SERIES 0 [Nm] P / N P / N P / N P / N Number of Contacts plug receptacle plug receptacle Type «A» REFERENCE Type «Z» NUMBER 0 A0 0 Z0 0 A0 0 Z0 crimp 0 A0 0 Z U A0 0 Z E see page J All specifications are typical and have to be adjusted according to * S - Shielded cable clamp the cable construction and dimensions. U - Unshielded cable clamp E - Sealed cable clamp For details see page L P All dimensions shown are in millimeters and are for reference only.

86 CABLE ASSEMBLY INSTRUCTIONS MULTIPOLE P Torque Wrench Size Wrench Size Extraction Insertion Positioner Crimping Cable Clamp * SERIES 0 [Nm] P / N P / N P / N P / N L B C Number of Contacts plug receptacle plug receptacle Type «A» REFERENCE Type «Z» NUMBER. 0 S... U A00 0 Z00. E S 0 TX00.0 TX00.0 TX U 0 TX00.0 TX00.0 TX E 0 TX00.0 TX00.0 TX A00 0 Z00 crimp. S... U.. 0 A0 0 Z0. E S TX00.0 TX00.0 TX U TX00.0 TX00.0 TX E TX00.0 TX00.0 TX A0 0 Z0 crimp see page J All specifications are typical and have to be adjusted according to * S - Shielded cable clamp the cable construction and dimensions. U - Unshielded cable clamp E - Sealed cable clamp For details see page L

87 MULTIPOLE CABLE ASSEMBLY INSTRUCTIONS SERIES Torque Wrench Size Wrench Size Extraction Insertion Positioner Crimping Cable Clamp * 0 0 [Nm] P / N P / N P / N P / N Number of Contacts plug receptacle plug receptacle L B C Type «A» REFERENCE Type «Z» NUMBER. S U A0 0 Z E... S TX00.0 TX00. TX00.. U TX00.0 TX00. TX A0 0 Z0 crimp E TX00.0 TX00. TX00.. S...0 U..0 E A0 0 Z0 see page J All specifications are typical and have to be adjusted according to * S - Shielded cable clamp the cable construction and dimensions. U - Unshielded cable clamp E - Sealed cable clamp For details see page L P All dimensions shown are in millimeters and are for reference only.

88 CABLE ASSEMBLY INSTRUCTIONS MULTIPOLE P Torque Wrench Size Wrench Size Extraction Insertion Positioner Crimping Cable Clamp * SERIES 0 [Nm] P / N P / N P / N P / N L B C Number of Contacts plug receptacle plug receptacle Type «A» REFERENCE Type «Z» NUMBER S...0 U..0 E A00 0 Z00 S. TX00. TX U TX00. TX E. TX00. TX A00 0 Z00 crimp.0 S/U.0.0 E 0 A0 0 Z0.0 S U 0..0 E A0 0 Z0..0 S U A0 0 Z0 E see page J All specifications are typical and have to be adjusted according to * S - Shielded cable clamp the cable construction and dimensions. U - Unshielded cable clamp E - Sealed cable clamp For details see page L

89 L B C S U E S U E MULTIPOLE CABLE ASSEMBLY INSTRUCTIONS Torque Wrench Size Wrench Size Extraction Insertion Positioner Crimping Cable Clamp * [Nm] P / N P / N P / N P / N Number of Contacts S 0..0 U 0.0 E 0..0 * S - Shielded cable clamp U - Unshielded cable clamp E - Sealed cable clamp For details see page L SERIES 0 plug receptacle plug receptacle Type «A» REFERENCE Type «Z» NUMBER See page P 0 A0 0 Z0 0 A0 0 Z0 0 A0 0 Z0 0 A0 0 Z0 All specifications are typical and have to be adjusted according to the cable construction and dimensions. P All dimensions shown are in millimeters and are for reference only.

90 CABLE ASSEMBLY INSTRUCTIONS MULTIPOLE P Torque Wrench Size Wrench Size Extraction Insertion Positioner Crimping Cable Clamp * SERIES 0 [Nm] P / N P / N P / N P / N L B C Number of Contacts plug receptacle plug receptacle Type «A» REFERENCE Type «Z» NUMBER S..0 U.0 E..0 0 A0 0 Z0 S.. TX00.0 TX00. TX U. TX00.0 TX00. TX E.. TX00.0 TX00. TX A0 0 Z0 crimp...0 S U.0 0 A0 0 Z0...0 E S..0.0 U A0 0 Z0 E S.. TX00.0 TX00. TX U TX00.0 TX00. TX E.. TX00.0 TX00. TX A0 0 Z0 crimp see page J All specifications are typical and have to be adjusted according to * S - Shielded cable clamp the cable construction and dimensions. U - Unshielded cable clamp E - Sealed cable clamp For details see page L

91 L B C MULTIPOLE CABLE ASSEMBLY INSTRUCTIONS Cable Clamp * SERIES Torque Wrench Size Wrench Size Extraction Insertion Positioner Crimping 0 [Nm] P / N P / N P / N P / N Number of Contacts plug receptacle plug receptacle Type «A» REFERENCE Type «Z» NUMBER...0 S U A0 0 Z0...0 E S.. TX00.0 TX00.0 TX U. TX00.0 TX00.0 TX A0 0 Z0 crimp E.. TX00.0 TX00.0 TX S U.0 0 A0 0 Z E S.. TX00.0 TX00.0 TX U. TX00.0 TX00.0 TX E.. TX00.0 TX00.0 TX A0 0 Z0 crimp see page J All specifications are typical and have to be adjusted according to * S - Shielded cable clamp the cable construction and dimensions. U - Unshielded cable clamp E - Sealed cable clamp For details see page L P All dimensions shown are in millimeters and are for reference only. 0

92 CABLE ASSEMBLY INSTRUCTIONS MULTIPOLE Torque Wrench Size Wrench Size Extraction Insertion Positioner Crimping Cable Clamp * [Nm] P / N P / N P / N P / N L B C Number of Contacts S... U.. E... S.. U. E.. S... U.. E... S... U.. E... * S - Shielded cable clamp U - Unshielded cable clamp E - Sealed cable clamp For details see page L P SERIES 0 plug receptacle plug receptacle Type «A» REFERENCE Type «Z» NUMBER 0 A0 0 Z0 0 A0 0 Z0 0 A0 0 Z0 See page P 0 A0 0 A0 0 Z0 0 A See page P 0 A0 All specifications are typical and have to be adjusted according to the cable construction and dimensions.

93 MULTIPOLE CABLE ASSEMBLY INSTRUCTIONS Torque Wrench Size Wrench Size Extraction Insertion Positioner Crimping Cable Clamp * [Nm] P / N P / N P / N P / N L B C Number of Contacts S U E S U E S U E S 0 U 0 E 0 * S - Shielded cable clamp U - Unshielded cable clamp E - Sealed cable clamp For details see page L SERIES 0 plug receptacle plug receptacle Type «A» REFERENCE Type «Z» NUMBER 0 A0 0 Z0 0 A0 0 Z0 0 A0 0 Z A0 0 Z0 All specifications are typical and have to be adjusted according to the cable construction and dimensions. P All dimensions shown are in millimeters and are for reference only.

94 CABLE ASSEMBLY INSTRUCTIONS MULTIPOLE Torque Wrench Size Wrench Size Extraction Insertion Positioner Crimping Cable Clamp * [Nm] P / N P / N P / N P / N L B C Number of Contacts S U E S U E.. S U.... E * S - Shielded cable clamp U - Unshielded cable clamp E - Sealed cable clamp For details see page L P SERIES 0 plug receptacle plug receptacle Type «A» REFERENCE Type «Z» NUMBER 0 A0 0 Z0 0 A0 0 Z A0 0 Z0 All specifications are typical and have to be adjusted according to the cable construction and dimensions.

95 MULTIPOLE CABLE ASSEMBLY INSTRUCTIONS Cable Clamp * SERIES Torque Wrench Size Wrench Size Extraction Insertion Positioner Crimping 0 [Nm] P / N P / N P / N P / N L B C Number of Contacts plug receptacle plug receptacle Type «A» REFERENCE Type «Z» NUMBER... S.... U A0 0 Z0... E.... S U A0 0 Z0.. 0 E S. TX00.0 TX00. TX00.0. U TX00.0 TX00. TX00.0. E. TX00.0 TX00. TX A0 0 Z0 crimp 0.. S..... U A0 0 Z E.... see page J All specifications are typical and have to be adjusted according to * S - Shielded cable clamp the cable construction and dimensions. U - Unshielded cable clamp E - Sealed cable clamp For details see page L P All dimensions shown are in millimeters and are for reference only.

96 CABLE ASSEMBLY INSTRUCTIONS MULTIPOLE P Torque Wrench Size Wrench Size Extraction Insertion Positioner Crimping Cable Clamp * SERIES 0 [Nm] P / N P / N P / N P / N L B C Number of Contacts plug receptacle plug receptacle Type «A» REFERENCE Type «Z» NUMBER 0.. S..... U.. 0 A0 0 Z E.... S 0. TX00.0 TX00.0 TX U TX00.0 TX00.0 TX E 0. TX00.0 TX00.0 TX A0 0 Z0 crimp S 0 0. TX00.0 TX00. TX U 0 TX00.0 TX00. TX00.. E 0 0. TX00.0 TX00. TX A 0 Z crimp 0 0 see page J All specifications are typical and have to be adjusted according to * S - Shielded cable clamp the cable construction and dimensions. U - Unshielded cable clamp E - Sealed cable clamp For details see page L

97 MULTIPOLE CABLE ASSEMBLY INSTRUCTIONS Torque Wrench Size Wrench Size Extraction Insertion Positioner Crimping Cable Clamp * [Nm] P / N P / N P / N P / N L B C Number of Contacts S U E 0 S U E S 0 U 0 E 0 0 S U E * S - Shielded cable clamp U - Unshielded cable clamp E - Sealed cable clamp For details see page L SERIES 0 plug receptacle plug receptacle Type «A» REFERENCE Type «Z» NUMBER 0 A00 0 Z00 See page P 0 A0 0 Z0 0 A00 0 Z00 0 A0 0 Z A0 0 Z0 0 0 All specifications are typical and have to be adjusted according to the cable construction and dimensions. P All dimensions shown are in millimeters and are for reference only.

98 CABLE ASSEMBLY INSTRUCTIONS MULTIPOLE Torque Wrench Size Wrench Size Extraction Insertion Positioner Crimping Cable Clamp * [Nm] P / N P / N P / N P / N L B C Number of Contacts S 0 U 0 E 0 0 S U E 0 * S - Shielded cable clamp U - Unshielded cable clamp E - Sealed cable clamp For details see page L P SERIES 0 plug receptacle plug receptacle Type «A» REFERENCE Type «Z» NUMBER A0 0 Z A0 0 Z0 0 0 All specifications are typical and have to be adjusted according to the cable construction and dimensions.

99 MULTIPOLE CABLE ASSEMBLY INSTRUCTIONS Torque Wrench Size Wrench Size Extraction Insertion Positioner Crimping Cable Clamp * [Nm] P / N P / N P / N P / N L B C Number of Contacts S 0 0 U 0 E 0 S 0 0 U 0 E 0 0 S U E 0 0 * S - Shielded cable clamp U - Unshielded cable clamp E - Sealed cable clamp For details see page L SERIES 0 plug receptacle plug receptacle Type «A» REFERENCE Type «Z» NUMBER 0 A0 0 Z0 0 A0 0 Z0 See page P 0 A0 0 Z A0 0 Z0 All specifications are typical and have to be adjusted according to the cable construction and dimensions. P All dimensions shown are in millimeters and are for reference only.

100 L B C 0 0 S U E 0 0 P CABLE ASSEMBLY INSTRUCTIONS MULTIPOLE Torque Wrench Size Wrench Size Extraction Insertion Positioner Crimping Cable Clamp * [Nm] P / N P / N P / N P / N Number of Contacts 0 0 S U E * S - Shielded cable clamp U - Unshielded cable clamp E - Sealed cable clamp For details see page L SERIES 0 plug receptacle plug receptacle Type «A» REFERENCE Type «Z» NUMBER 0 A0 0 Z0 0 A0 0 Z All specifications are typical and have to be adjusted according to the cable construction and dimensions.

101 L B C 0 0 S U E MULTIPOLE CABLE ASSEMBLY INSTRUCTIONS Torque Wrench Size Wrench Size Extraction Insertion Positioner Crimping Cable Clamp * [Nm] 0 P / N P / N P / N P / N Number of Contacts * S - Shielded cable clamp U - Unshielded cable clamp E - Sealed cable clamp For details see page L SERIES 0 plug receptacle plug receptacle Type «A» REFERENCE Type «Z» NUMBER 0 A0 0 Z0 All specifications are typical and have to be adjusted according to the cable construction and dimensions. P All dimensions shown are in millimeters and are for reference only. 0

102 CABLE ASSEMBLY INSTRUCTIONS HIGH VOLTAGE Torque Wrench Size Wrench Size Extraction Insertion Positioner Crimping Cable Clamp * [Nm] P / N P / N P / N P / N L B C Number of Contacts S..0 UI 0.0 S 0. UI. E 0. S + E.. UI + E. E + E 0.. S.. UI. E 0.. S UI S 0 UI (S + SE 0 A0) TP E 0 * S - Shielded cable clamp UI - Insulating cable clamp E - Sealed cable clamp For details see page L P SERIES HT plug receptacle plug receptacle Type «A» REFERENCE Type «Z» NUMBER 0 A0 0 Z0 0 A0 0 A E E 0 A0 0 Z0 0 A0 0 Z0 0 A0 0 Z0 All specifications are typical and have to be adjusted according to the cable construction and dimensions.

103 CABLE GROUPS FOR COAXIAL, TRIAXIAL & MIXED CONNECTORS Gr. No 0 Designation US MIL-C- Impedance ohms Center Conductor Dielectric Cable Screen Construction [mm] [mm] Material [mm] Material Cable Jacket [mm] Material IEC Publication 00- or Manufacturer RG-B/U 0± x 0. AcCuAg PTFE. CuAg. FEP 0-- RG-A/U 0± x 0. AcCuAg PTFE. CuAg.0 PTFE 0-- RG-A/U 0± x 0. AcCu 0.. PE.0 CuSn. PVC RG-/U 0± x 0. AcCu 0.. PE.0 CuSn. PVC 0-- RG-B/U 0± x 0. AcCuAg PTFE. CuAg. FEP 0-- RG-A/U 0± x 0. AcCuAg 0.. PTFE.0 CuAg. FEP 0-- RG-A/U 0± x 0. AcCuAg PTFE. CuAg.0 PTFE 0-- RG-/U 0± x 0. AcCuAg 0.. PTFE.0 CuAg. FEP 0-- RG-B/U ± x 0. AcCuAg 0.. PTFE.0 CuAg. FEP -- LiYCY x 0. mm x 0. CuSn 0.. PVC. CuSn. PVC LifYCY x 0.0 mm 0 x 0.0 CuSn PVC. CuSn. PVC RG-0B/U ± x 0. AcCuAg 0.. PTFE. CuAg. FEP BELDEN ± x 0. AcCu 0.. PE.0 CuSn. PVC Belden(USA) RG-/U 0± x 0. CuSn 0.. PE. CuSn. PVC LiYCY x 0. mm x 0. CuSn 0.. PVC. CuSn. PVC LiYCY x 0. mm x 0. CuSn 0.. PVC.0 CuSn. PVC RG-C/U 0± x 0. CuSn 0.. PE. CuSn.0 PVC 0-- RG-A/U 0± x 0. AcCuAg 0.. PTFE. CuAg. PTFE 0-- RG-B/U 0± x 0. AcCuAg 0.. PTFE. x CuAg.0 FEP RG-0/U 0± x 0. AcCuAg 0.. PTFE. CuAg. FEP RG-00/U 0± x 0. CuAg.0. PTFE. x CuAg.0 FEP GORE GCX 0 0±% x 0. CuAg.0. Gore-Tex. CuAg. FEP Gore (D) LiYCY x 0.0 mm x 0. CuSn 0.. PVC. CuSn. PVC LiYCY x 0. mm x 0. CuSn..0 PVC. CuSn. PVC LifYCY x 0.0 mm x 0.0 CuSn.0.0 PVC. CuSn. PVC LifYCY x 0. mm x 0.0 CuSn.. PVC. CuSn. PVC RG-B/U ± x 0. AcCu 0.. PE. Cu. PVC RG-/U 0± x 0. CuAg 0.. PE. x CuAg. PVC 0-- RG-0/U ± x 0. AcCuAg 0.. PTFE. CuAg. FEP -- RG-/U 0± x. CuAg.. PE. x CuAg. PVC RG-/U 0± x. CrNi.. PE. x CuAg. PVC SUHNER G 0 0± x 0. Cu.. PE. Cu. PVC Suhner (CH) RG-A/U ± x 0. AcCu 0.. PE. CuAg. PVC RG-A/U 0± x 0. CuAg.. PTFE.0 x CuAg 0. PTFE RG-/U 0± x 0. CuAg.. PTFE.0 CuAg 0. PTFE 0-- RG-/U 0± x 0. Cu.. PE. Cu 0. PVC 0-- RG-A/U ± x 0. CuSn.. PTFE. Cu 0. PVC -- RG-/U 0± x 0. CuAg.. PE. x CuAg 0. PVC RG-/U 0± x. Cu.. PE. x Cu. PVC RG-0/U 0± x. Cu.. PTFE. x CuAg. PVC RG-A/U ± RG-A/U armoured with zinc plated steel braid. FeZn RG-B/U ± x 0. Cu.. PE. Cu.0 PVC RG-/U 0± x.0 Cu.0. PE. x CuAg. PVC 0 RG-/U 0± x.0 Cu.0. PE. Cu. PVC 0-- RG-/U ± x. Cu.. PE. Cu. PVC -- RG-0/U 0± x 0. AcCuAg PTFE. CuAg. FEP Habia (UK) Triaxial. screen and jacket:. CuAg. FEP RG- 0± x 0. AcCuAg 0.. PTFE. CuAg. FEP Filotex (F) Type Triax. screen and jacket:. CuAg. FEP SUHNER G 0 0± x 0. Cu 0.. PE.0 Cu. PVC Suhner (CH) Triaxial. screen and jacket:.0 Cu. PVC BELDEN 0± x 0. CuSn 0.. PE. CuSn. PE Belden (USA) RG- Type Triax. screen and jacket:. CuSn. PVC ALPHA 0 ± x 0. AcCu 0.. FPE. Cu - PE Alpha (UK) RG- Type Triax. screen and jacket: Cu.0 PVC BELDEN ± x 0. Cu 0.. FPE. Cu. PE Belden (USA) RG- Type Triax. screen and jacket:. Cu. CSM Insulated, stranded wires with screen and jacket, standardized by the German VDE 0, for low frequency applications when no defined impedance is required. Insulated, highly flexible stranded wires with screen and jacket, for low frequency applications when no defined impedance is required. Legend Cu Plain copper wire FEP Fluorethylenepropylene CSM Hypalon (DuPont) CuAg Silver plated copper wire FPE Foam polyethylene CuSn Tin plated copper wire PE Polyethylene StCu Copper-clad steel wire PTFE Polytetrafluorethylene StCuAg Copper-clad steel wire, silver plated PVC Polyvinyl chloride Q All dimensions shown are in millimeters and are for reference only.

104 SPECIAL REQUIREMENTS Company / Name:... Date: Address:... If your particular need for special connectors is not included in any of our catalogues, we shall be pleased to submit to you with the minimum of delay, and naturally without charges, a design meeting your requirements. In order to avoid any loss of time asking you for further details, please provide us with the fullest information possible, such as:. Multipole, coaxial or mixed connectors.... Body styles required.... Number of contacts.... Working or test voltages, AC or DC.... Max. current per contact.... Frequency range.... Impedance.... Other feed-through requirements.... Construction and dimensions of cable Limitation on size or space available Application Conditions of operation: a) Temperature... b) Degree of sealing in water or gas... c) Radiation resistance.... Special features Price limits.... Quantities expected... a) short term requirement... b) yearly required quantities.... Desired delivery dates... a) for the proposal of a solution... R b) for how many prototypes... c) for the first production run... Please include any relevant drawing of the cable and/or sketches of your proposed design. We and our representatives are at your entire disposal to examine your particular problems.

105 WARRANTY AND DISCLAIMER WARRANTY AND DISCLAIMER A limited warranty applies to Fischer Connectors SA products. Except for obligations assumed by Fischer Connectors SA under warranty, Fischer Connectors SA, its subsidiaries, and agents, will not be liable for any loss, damage, cost of repairs, incidental or consequential damages of any kind, whether or not based upon express or implied warranty, contract, negligence, or strict liability arising in connection with the design, manufacture, sale, use, or repair of the products. Fischer Connectors SA warrants that each product sold is in accordance with Fischer specifications, drawings, samples, or data in effect on the date of receipt of the order and that each unit is free from defects in material and workmanship. Fischer's liability under this warranty is limited to the repair or replacement of any unit which proves to be defective in material or workmanship under normal use or service within one year from date of shipment, provided the unit is returned at purchaser's expense to seller's shipping point. No material is accepted for analysis, replacement or repair without the written agreement of Fischer Connectors SA, or its subsidiaries or agents. This warranty is in lieu of all other warranties, expressed or implied. All of the information included in this catalog, including any other illustrations and documentation which may be provided by Fischer Connectors SA, is believed to be accurate at the time of printing. It is recommended, however, that users should independently evaluate the suitability of each product for their intended application. Fischer Connectors SA makes no warranties as to the accuracy or completeness of the information, and disclaims any liability regarding its use. R

106 INDEX S Accessories cable bend relief caps, sealing color, identification washers contact size, wire gauge conversion grounding washers insulating washers knurled clamp nuts sleeves, sealing spacers Assembly and Mounting cable instructions mounting instructions mounting nuts nut driver panel cut-out dimensions spanners tools, contact extraction tools, contact insertion tools, crimp tools, crimp positioners torque, mounting wrenches Body Style CAMAC Connectors Cable clamp sets see «Clamps» Clamps insulating types, general type «S» for shielded cable type «U» for unshielded cable type «E» sealed, for all cables For WSO For WS/WSE Coax and Triax cables cable groups, recommended cables Contacts crimp diameter equivalent wire gauge insertion tools maximum wire gauge numbering p.c.b. style plating termination types thermocouple Dimensions Feedthrough - Double-ended WDE - hermetic sealed High Voltage coax contact protection dimension mixed contact multipole style Insulating Material Keying and Orientation J-J J-J J J J J J J, J J, M J N, O-P N J, J K N K K, O-P K, O-P K, K, O-P K, J, P-P0 N, O-P K A-A D C, C-C, H, L A, H-H0 A, A, H-H, L A, A, H-H, L A, A, H-H, L H, L H0, L D-D, F Q D-F, J, L, N D-F, J J K, K, O-P J, D-F P-P D-D, E-E, L L L, N L G, G A, B-B0, C-C A, B, L, M-M C, C, D-D A, C, L C-C, P C, F C, E-E D-F, L L, N Latching Mechanism Materials elastomers, technical characteristics metal, technical characteristics plastic, technical characteristics Ordering Information Plating and surface treatment L L L L-L A, A Plugs - Cable Mount S - locking A, B, C-C, M SA - with lanyard A, B SC - Clic-Loc A, B, M SOV - non-locking A, B, M SV - tamper-proof A, B, C-C SS - short A, B WS - right-angle A, B WSE - sealed, right-angle A, B, M-M WSO - sealed, right-angle A, B, M-M Plugs - Panel Mount SF - standard, non-locking A, B SFE - hermetic, non-locking A, B, M-M SFU - IP sealed, non-locking A, B Quality, Certificate of Approval Questionnaire, Special Requirements Ratings current derating curve, current dielectric strength IEC impedance IP radiation resistance residual leakage temperature volume resistivity voltage, operating voltage, test Receptacles - Cable Mount K - standard KE - sealed L L R D-F, L L L L, L D-D, F M-M L M L-L L L D-F, L A, B, M A, B, M-M Receptacles - Panel Mount D - standard, flush mounted A, B, C-C DB - front projecting A, B, M DBEE - hermetic, front projecting A, B, M-M DBEU - IP sealed, front projecting A, B, M, M DBP - rear mounted A, B DBPC - right-angle p.c.b. contacts A, B, B DBPE - hermetic, rear mounted A, B, M-M DBPU - IP sealed, rear mounted A, B, M-M DEE - hermetic, flush mounted A, B, C, M-M DEU - sealed per IP A, B, M-M DG - completely threaded, contacts A, B DGP - completely threaded, p.c.b. contacts A, B DK - with cable clamp A, B0 DKBE - sealed rear-mounted cable receptacle A, B, M-M DKE - sealed with cable clamp A, B0, M-M Sealed Connectors Sectional view of plug and receptacle Thermocouple Triax Camera Connectors M-M L G-G D

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH General information These connectors are designed and produced in conformity with the low-voltage directive (/3/EWG) respectively

More information

8D Series Common Section

8D Series Common Section MIL-DTL-38999 qualified crimp contacts - 1.27µm gold plated #22D type Part number Ø M39029/58 360 M39029/56 348 Conductor section AWG Conductor section mm² External Ø over insulator Min Max Min Max Min

More information

HARTING D-Sub Selection Guide

HARTING D-Sub Selection Guide HARTING D-Sub Selection Guide People Power Partnership D-Sub Selection Guide D-Sub Device Connectivity HARTING Connectivity & Networks generates solutions throughout the triad of Installation Technology,

More information

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series Amphenol Amphenol-Tuchel Electronics GmbH Circular Connectors C 09 A/B/D Series The Company Amphenol-Tuchel Electronics GmbH is a member of the USA based Amphenol Corporation. With our own global presence

More information

Connector~Tech Providing Harsh Environment Connector

Connector~Tech   Providing Harsh Environment Connector Connector~Tech www.connectortech.com.au Providing Harsh Environment Connector SOLUTIONS Tajimi TC18 series connectors are water-pro up to 30 meters in depth. Economical and highly reliable construction

More information

Series Shrink Boot Adapters. Series Shrink Boot, EMI/RFI, Strain Relief. Series Shrink Boot, EMI/RFI, Shield Sock

Series Shrink Boot Adapters. Series Shrink Boot, EMI/RFI, Strain Relief. Series Shrink Boot, EMI/RFI, Shield Sock Product Selection Guide How For a complete Table of Contents please see the last page of this book Series 310 - Shrink Boot Adapters The adapters in this section are designed to accommodate lipped-type

More information

2mm Hard Metric Connectors

2mm Hard Metric Connectors A KYOCERA GROUP COMPANY 2mm Hard Metric Connectors Contents Introduction........................................ Technical Specifications............................. 2 Multi-Line Module Connectors for

More information

Imformation of C091D series

Imformation of C091D series Imformation of C09D series The QTY of contacts is -pin to -pin, the connection method for the thread type, pinhole connections for welding type, press-fit and PCB type. This series of connectors to prevent

More information

High Power Contacts - Up to 850A

High Power Contacts - Up to 850A 8 Series igh Power Contacts igh Power Contacts - Up to 850 esigned to meet the harshest military requirements where high power and shielding are needed. 3 aluminum shell sizes available Size 19 (450 max);

More information

Mineral-insulated thermocouples to DIN and EN

Mineral-insulated thermocouples to DIN and EN Data Sheet 90.1210 (90.1221) Page 1/7 s to DIN 43 710 and EN 60 584 for temperatures from -200 to +1200 C flexible sheath with shock-proof measuring insert protection tube diameter from 0.5mm fast response

More information

SIM Mono Module Push Pull Connectors

SIM Mono Module Push Pull Connectors SIM Mono Module Push Pull Connectors EN RINC 809 Immeuble le Doublon avenue Dubonnet 90 COURBEVOIE Cedex FRNCE Version. Tel : (0) 9 0 0 00 Fax : (0) 9 0 0 0 www. amphenol-airlb. fr PRESENTTION PRT NUMBERING

More information

Amphenol Amphenol-Tuchel Electronics GmbH. C 091 A/B/D Series. Circular Connectors.

Amphenol Amphenol-Tuchel Electronics GmbH. C 091 A/B/D Series. Circular Connectors. mphenol mphenol-tuchel Electronics GmbH C 09 //D Series Circular Connectors www.industrial-amphenol.com Note from the CEO Ladies and Gentlemen, For over years mphenol has enjoyed success as the interconnection

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for

More information

Our Most Important Connection is with You. SECTION 8. Quick-Lock: QMA / WQMA / QN / QRE R123 / R123W / R164 / R324

Our Most Important Connection is with You. SECTION 8. Quick-Lock: QMA / WQMA / QN / QRE R123 / R123W / R164 / R324 SECTION 8 Quick-Lock: QM / WQM / QN / QRE R123 / R123W / R164 / R324 Contents QM and WQM Introduction... 8-4 to 8-5 Characteristics... 8-6 to 8-7 QM plugs and jacks... 8-8 to 8-9 QM receptacles...8-9 to

More information

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2... Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed

More information

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for

More information

Amphenol. BACKSHELLS For LJT, RNJ, RNJ LP, JT, TV-CTV, SC39 AND SJT connectors. For MIL-DTL series I,II,III and VG96912 connectors

Amphenol. BACKSHELLS For LJT, RNJ, RNJ LP, JT, TV-CTV, SC39 AND SJT connectors. For MIL-DTL series I,II,III and VG96912 connectors Amphenol For LJT, RNJ, RNJ LP, JT, TV-CTV, SC39 AND SJT connectors For MIL-DTL-38999 series I,II,III and VG96912 connectors www.38999-solutions.com - www.amphenol-socapex.com

More information

Size A DIN EN

Size A DIN EN Size A DIN EN 70-0 Actuators 0 series DIN EN 70-0 +, + ow and high housing Degree of protection IP6 Wired versions Moulded versions Degree of protection IP67 Contacts Thread Cable outlet Ordering-No. Female

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for

More information

General-purpose Multi-Contact Circular Waterproof Connectors

General-purpose Multi-Contact Circular Waterproof Connectors General-purpose Multi-ontact ircular Waterproof onnectors RM-W Series Plug _ straight Ø. Ø Long backshell Overview High performance waterproof circular connectors and cable assemblies used in variety of

More information

Single Module EN4165 ARINC BACC 65 EN4165. The New Standard Connector for Aircraft equipment and cabin systems. Advantages

Single Module EN4165 ARINC BACC 65 EN4165. The New Standard Connector for Aircraft equipment and cabin systems. Advantages Single Module EN4165 ARINC 809 - BACC 65 EN4165 The New Standard Connector for Aircraft equipment and cabin systems. Advantages Light weight composite, modularity, color coded, push pull coupling are the

More information

What You Need to Get Started INSTALLATION GUIDE

What You Need to Get Started INSTALLATION GUIDE INSTALLATION GUIDE SBS-96F SHIELDED BACKSHELL This guide describes how to assemble and install the SBS-96F shielded backshell with low-voltage SCXI modules, VXI-DAQ modules, or low-voltage TBX terminal

More information

The Working Environment

The Working Environment How How The Working Environment The broad range of backshell types available today makes it critical for interconnect engineers, and others tasked with the responsibility of specifying connector accessories

More information

Universal limit switches

Universal limit switches SWITCHES.CROUZET.COM 1 LIMIT SWITCHES 0/016 Universal limit switches 8384 standard 8384 with positive break operation Conformity to standards IEC / EN 60947--1, including Annex K for version with positive

More information

Amphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme

Amphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme Amphenol Amphenol-Tuchel Electronics GmbH Series C 146 Heavy Duty Connectors Core Programme The Company General information These connectors are designed and produced in conformity with the voltage directive

More information

Ÿ 9-50-way std density Ÿ way high Density Ÿ Mixed layout constructions ( e.g. 7W2, 9W4, 17W5) Ÿ Power constructions in 20A -40A ( e.g.

Ÿ 9-50-way std density Ÿ way high Density Ÿ Mixed layout constructions ( e.g. 7W2, 9W4, 17W5) Ÿ Power constructions in 20A -40A ( e.g. Ÿ 9-50-way std density Ÿ 15-78 way high Density Ÿ Mixed layout constructions ( e.g. 7W2, 9W4, 17W5) Ÿ Power constructions in 20A -40A ( e.g., 3W3, 5W5, 8W8) Ÿ Feed-through capacitor & pi filter constructions

More information

Assembly Instructions for the 1-Wire Weather Station V2.0/V3.0

Assembly Instructions for the 1-Wire Weather Station V2.0/V3.0 Assembly Instructions for the 1-Wire Weather Station V2.0/V3.0 Tools and Supplies Required (not included): Phillips screwdriver 3/8" wrench Drill with 5/32" bit "U" type mounting bracket (i.e., part number

More information

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

RF Power Feed-Through Capacitors with Conductor Rod, Class 1 Ceramic

RF Power Feed-Through Capacitors with Conductor Rod, Class 1 Ceramic DB 030088, DB 03000 RF Power Feed-Through Capacitors with Conductor Rod, Class Ceramic FEATURES Small size Geometry minimizes inductance Wide range of capacitance values APPLICATIONS Filtering purposes

More information

CDS. high density spring connection

CDS. high density spring connection CDS high density spring connection DENSTY STANDARD 1A CDS DENSTY A A spring connection CDS Series The originality of multipole connectors represents one of the core values of LE, a leading company in this

More information

ATEX/IECEx RTD temperature probe

ATEX/IECEx RTD temperature probe Page 1/8 ATEX/IECEx RTD temperature probe with connecting cable acc. to DIN EN 60751 For temperatures from -100 to +600 C As single, double, or triple RTD temperature probe In two-wire, three-wire, or

More information

SUBMINIATURE MICROSWITCHES - PREMIUM

SUBMINIATURE MICROSWITCHES - PREMIUM 0/08 SUBMINIATUE MICOSWITCHES - PEMIUM V - 870 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed atings from ma Vc up to (6) A 0

More information

Temperature measurement

Temperature measurement Temperature measurement 19 2 Example of connections of particular elements Temperature display units BGK85 (page 31) Option Computer, control, itp. Temperature measurement TFC TFL (page 23) (page 23) Temperature

More information

Installation guide 862 MIT / MIR

Installation guide 862 MIT / MIR Installation guide 862 MIT / MIR in combination with: 864 MTT or 863 MRT or (dual) spot element November 2005 Part no. 4416.232_Rev3 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100

More information

microswitches Low force

microswitches Low force 0/06 Subminiature MICOSWITCHES - PEMIUM V - 870 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed atings from ma Vc up to (6) A

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T... Magnetic and Hydraulic-Magnetic Circuit Breaker 830-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of

More information

General characteristics

General characteristics General characteristics This range of insulators and partition bushings provides for connecting and supporting low- and medium-voltage electrical equipment. - Their purpose is to provide electrical and

More information

CONNECTORS, ELECTRICAL, RECTANGULAR, MICROMINIATURE, NON-REMOVABLE GAUGE 26 PCB PIN CONTACTS BASED ON TYPE 8MCG

CONNECTORS, ELECTRICAL, RECTANGULAR, MICROMINIATURE, NON-REMOVABLE GAUGE 26 PCB PIN CONTACTS BASED ON TYPE 8MCG Page 1 of 27 CONNECTORS, ELECTRICAL, RECTANGULAR, MICROMINIATURE, NON-REMOVABLE GAUGE 26 PCB PIN CONTACTS BASED ON TYPE 8MCG Issue 6 June 2018 Document Custodian: European Space Agency see https://escies.org

More information

Table of Contents Pin-Configuration Selection Guide for HDE, HDS, & EFP

Table of Contents Pin-Configuration Selection Guide for HDE, HDS, & EFP Table of Contents -Configuration Selection Guide for HDE, HDS, & EFP Service Voltage Rating... Electrical Service Ratings... Ampacity Ratings by Contact... Electrical Service Ratings Explained... Operating

More information

Load Washers. Force kn until kn. Type 9101A A

Load Washers. Force kn until kn. Type 9101A A Force Load Washers 0... 20 kn until 0... 700 kn Type 9101A... 9107A Force sensor for measuring quasistatic and dynamic forces in industrial monitoring tasks. F z The force sensors are delivered uncalibrated

More information

MINIATURE MICROSWITCHES - PREMIUM

MINIATURE MICROSWITCHES - PREMIUM 0/08 MINIATURE MICROSWITCHES - PREMIUM V - 86 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed Broad range of operating forces

More information

8ST Series VG96912 & JN1003. Connection Technologies

8ST Series VG96912 & JN1003. Connection Technologies Connection Technologies Contents Overview Presentation... 06 Applications... 06 A universal product platform... 07 Contact layouts... 08 Contact layouts (matrix)... 12 Cross reference list... 14 Dummy

More information

File E28476 Vol. 7 Sec. 44 Page 1 Issued: Vol. 23 Sec. 18 Revised: Vol. 67 Sec. 4 and Report D E S C R I P T I O N

File E28476 Vol. 7 Sec. 44 Page 1 Issued: Vol. 23 Sec. 18 Revised: Vol. 67 Sec. 4 and Report D E S C R I P T I O N File E28476 Vol. 7 Sec. 44 Page 1 Issued: 1990-08-07 Vol. 23 Sec. 18 Revised: 2014-04-18 PRODUCT COVERED: USR - Series SL.156 Connectors. D E S C R I P T I O N USR - SL-156 Connectors, Receptacle Part

More information

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR 19 TECHNOLOGY. NET Protector Surge Arrester. Protects switches, HUBs and telecommunication

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR 19 TECHNOLOGY. NET Protector Surge Arrester. Protects switches, HUBs and telecommunication Surge Arrester Protects switches, HUBs and telecommunication systems Class D according to EN 0 possible (Gigabit Ethernet) Variably equippable patch panels Units available with plug-in inputs and outputs

More information

Thermal-Magnetic Circuit Breaker 2210-T2...

Thermal-Magnetic Circuit Breaker 2210-T2... Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring

More information

ZF Series Force Transducers

ZF Series Force Transducers Data Sheet Series Force Transducers FEATURES 1 kn to 00 kn High accuracy For tensile or pressure forces Made of stainless steel Enclosure protection IP 67 DESCRIPTION The force transducers of the series

More information

Pressure Transmitter ED 701

Pressure Transmitter ED 701 Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation

More information

RJ Connector. IP 67 Receptacle I Unmated & Mated Overmolded with Cable I Mated Field Installable I Mated. RJ Connector I Range Overview

RJ Connector. IP 67 Receptacle I Unmated & Mated Overmolded with Cable I Mated Field Installable I Mated. RJ Connector I Range Overview RJ Connector RJ Connector I Range Overview RJ Connector IP 67 Receptacle I Unmated & Mated I Mated I Mated 8-1 TW Technology Co., td. RJ Connector I Range Overview Range Overview Receptacle and Mating

More information

DRAWING ISO 200 REV. "R" TYP TYP SLOT OPTIONAL .130 TYP KNURL STYLE - MFG. OPTION

DRAWING ISO 200 REV. R TYP TYP SLOT OPTIONAL .130 TYP KNURL STYLE - MFG. OPTION .500 SHELL I.D. 0.39.135 F T TOP ENTRY H J K SLOT OPTIONAL E END ENTRY G.062.062 0.49 P.130 KNURL STYLE - MFG. OPTION R S M DIMENSIONS PART # P N CABLE ENTRY ISO - 100 0.36 0.37 02 THRU 33 ISO - 200 0.57

More information

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity VX Enclosure System Technical documentation PE conductor connection, current carrying capacity Enclosure system VX Contents Contents. General remarks. Introduction. Notes on the design of the earthing

More information

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA 300

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA 300 INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN 37850 Application: HONDA 300 Your safety, and the safety of others, is very important. To help you make informed decisions about safety, we have

More information

PN LINE. PN Line. PX Line. PA Line. PU Line PX LINE. PV Line PA LINE & TUBINGS PU LINE PV LINE. Brass Push-in fittings

PN LINE. PN Line. PX Line. PA Line. PU Line PX LINE. PV Line PA LINE & TUBINGS PU LINE PV LINE. Brass Push-in fittings I NDEX PV LINE PX LINE PU LINE PA LINE & TUBINGS PN LINE Brass Push-in fittings Stainless Steel Push-in fittings Brass Standard fittings and Flexible Hoses Couplings and Multiple Connectors Function fittings

More information

UNIPOLE & MULTIPOLE CONNECTORS

UNIPOLE & MULTIPOLE CONNECTORS UIPOE & UTIPOE COECTORS o reproduction or use without express permission of editorial or pictorial content, in any manner. Printed in Switzerland, 00 EO SA EO reserve the right at all times to modify and

More information

RF Power Feed-Through Capacitors with Conductor Rod, Class 1 Ceramic

RF Power Feed-Through Capacitors with Conductor Rod, Class 1 Ceramic DB 06030, DB 06040, DB 06060 RF Power Feed-Through Capacitors with Conductor Rod, Class Ceramic FEATURES Small size Geometry minimizes inductance Wide range of capacitance values APPLICATIONS Filtering

More information

Flexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB March 2008

Flexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB March 2008 Flexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB41-078 March 2008 FT-19R and FT-19RX FT-19R 3RU with Individual Clear Covers APPLICATION FEATURES The type FT-19R (standard length) and

More information

Temperature Measurement

Temperature Measurement Temperature Measurement 157 12 Precise and reliable measurements even in aggressive liquids all probes are encapsulated with PTFE for maximum chemical resistance. PRODUCT TIPS Page 161: 143 PT100 Temperature

More information

C V S T B T 1 0 ( )

C V S T B T 1 0 ( ) SLIDE SINGLE SWITCHES TURN WIREWOUND ( mm TRIMMERS PITCH) -6/- -T 6 FEATURES Lowest profile design of. mm Fine pitch of mm Easy motion with knob height of 0. mm 6 Part Part name name Material Material

More information

MINIATURE MICROSWITCHES - PREMIUM

MINIATURE MICROSWITCHES - PREMIUM 0/06 MINIATURE MICROSWITCHES - PREMIUM V - 86 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed Broad range of operating forces

More information

Conductivity sensor for hygienic applications

Conductivity sensor for hygienic applications Conductivity sensor for hygienic applications Type 8221 can be combined with Perfect for demanding applications in the hygienic industry (CIP and SIP compatible) Variants available for usage over a wide

More information

DATA SHEET. Thermocouple module with digital I²C-Interface - THMOD-I²C. Characteristic features. Areas of application. Features.

DATA SHEET. Thermocouple module with digital I²C-Interface - THMOD-I²C. Characteristic features. Areas of application. Features. Description Characteristic features Industrial temperature measuring method Wide measuring range, -270...+1360 C Digital I²C-interface Simple integration to micro-controller Scope of supply with thermocouple,

More information

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA 400

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA 400 INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN 37851 Application: HONDA 400 Your safety, and the safety of others, is very important. To help you make informed decisions about safety, we have

More information

SECTION VII ILLUSTRATED PARTS BREAKDOWN

SECTION VII ILLUSTRATED PARTS BREAKDOWN SECTION VII ILLUSTRATED PARTS BREAKDOWN 7-1 INTRODUCTION This Illustrated Parts Breakdown (herein referred to as the IPB) identifies, illustrates and describes the parts for the ITA and its subassemblies.

More information

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop TECHNICA DATASHEET D-P--C Rope Safety Switches with reset for emergency stop Metal or polymer housing, from one or three conduit entries Protection degree IP6 In conformity with EN ISO 13850 contact blocks

More information

UNIPOLE & MULTIPOLE CONNECTORS

UNIPOLE & MULTIPOLE CONNECTORS UIPOE & UTIPOE COECTORS EO unipole and multipole connectors This catalogue gives the complete description of EO unipole and multipole type connectors. The EO manufacturing programme has been extended to

More information

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA MODELS: 450S AND 450ES

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA MODELS: 450S AND 450ES INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN 37852 Application: HONDA MODELS: 450S AND 450ES Your safety, and the safety of others, is very important. To help you make informed decisions about

More information

INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: (50 ), (54 ), or (60 ) Application: All Terrain Vehicles

INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: (50 ), (54 ), or (60 ) Application: All Terrain Vehicles INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: 78950 (50 ), 78954 (54 ), or 78960 (60 ) Application: All Terrain Vehicles Your safety, and the safety of others, is very important. To help you make

More information

DIM. A (+ 0,05 0,51) .135 ±.015 (3,43 ± 0,38) COMMON LUG INTEGRAL ASSEMBLY NUT, DO NOT REMOVE 1/4-32 UNEF-2A THREAD

DIM. A (+ 0,05 0,51) .135 ±.015 (3,43 ± 0,38) COMMON LUG INTEGRAL ASSEMBLY NUT, DO NOT REMOVE 1/4-32 UNEF-2A THREAD Multi-Deck SERIES 0 SERIES 0 0." Diameter, / Amp, Standard, Military SR FEATURES Proven Quality in Thousands of Applications Gold-plated Contact System 0,,, 0 and 0 Angle Options MIL Qualified Versions

More information

Lecture 36: Temperatue Measurements

Lecture 36: Temperatue Measurements Lecture 36: Temperatue Measurements Contents Principle of thermocouples Materials for themocouples Cold junction compensation Compensating wires Selection of thermocouples Illustration of gas temperature

More information

This specification covers the requirements for product performance, test methods and quality assurance provisions of FG Terminal.

This specification covers the requirements for product performance, test methods and quality assurance provisions of FG Terminal. DESIGN OBJECTIVES The product described in this document has not been fully tested to ensure conformance to the requirements outlined below. Therefore AMP Ltd makes no representation or warranty, express

More information

SUBMINIATURE MICROSWITCHES - STANDARD

SUBMINIATURE MICROSWITCHES - STANDARD 0/08 SUBMINIATURE MICROSWITCHES - STANDARD VD - 87 Flexible leaf snap-action mechanism with wiping contacts Ratings from 0.0 A Vc to (6) A 0 Va and / hp -0 Va ENEC and curus approved up to +0 C Housing

More information

TX14/15 SERIES CONNECTORS

TX14/15 SERIES CONNECTORS The leaf-type design (non-pin) contact of this board-to-board connector is superior in reliability and stability due to its resistance to twisting. The receptacle (TX1) and plug (TX15) combination can

More information

Industrial Pressure Transmitter

Industrial Pressure Transmitter ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter

More information

PERFORMANCE SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET INCH-POUND MIL-PRF-64266/13A w/ Amendment 1 1 December 2014 SUPERSEDING MIL-PRF-64266/13A 15 October 2013 PERFORMANCE SPECIFICATION SHEET CONNECTORS, FIBER OPTIC, CIRCULAR, PLUG AND RECEPTACLE STYLE, MULTIPLE

More information

Single Contacts. ODU Springtac Contacts and ODU Lamella Contacts. Ø 0,76 mm to Ø 60 mm

Single Contacts. ODU Springtac Contacts and ODU Lamella Contacts. Ø 0,76 mm to Ø 60 mm Catalogue No. 0-e Single Contacts ODU Springtac Contacts and ODU Lamella Contacts Ø 0, mm to Ø 0 mm rue René Laennec 0 Taissy France Fax: 0 0, Tel : 0 9 9 E-mail:hvssystem@hvssystem.com Site web : www.hvssystem.com

More information

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components: SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine

More information

2.3. Rockers. Contents

2.3. Rockers. Contents . SVRSealed Vehicle SVRSealed Vehicle Rocker Contents Description SVRSealed Vehicle Above Panel Rocker Switch............... Below Panel Rocker Switch............... Technical Data and Specifications..........

More information

KM-1600SWH KM-1600SRH KM-1600SWH3 KM-1600SRH3

KM-1600SWH KM-1600SRH KM-1600SWH3 KM-1600SRH3 NO. ISSUED: REVISED: 71193 OCT. 2, 2001 JAN. 27, 2003 HOSHIZAKI STACKABLE CRESCENT CUBER MODELS KM-1600SWH KM-1600SRH KM-1600SWH3 KM-1600SRH3 PARTS LIST KM-1600SWH L-0 June, 2001 M-0 Feb., 2002 M-1 Feb.,

More information

American Zettler AZ742 RELAY Datasheet

American Zettler AZ742 RELAY Datasheet American Zettler AZ74 RELAY Datasheet http://www.manuallib.com/american-zettler/az74-relay-datasheet.html FEATURES Dielectric strength 000 Vrms Low height:.7 mm Epoxy sealed version available 0 Amp switching

More information

HiPace 300 with TC 110, DN 100 CF-F

HiPace 300 with TC 110, DN 100 CF-F HiPace 300 with TC 110, DN 100 CF-F HiPace 300 with TC 110, DN 100 CF-F Rugged, powerful turbopump with a pumping speed of up to 260 l/s for N 2 Integrated TC 110 drive electronics Ideal for UHV applications

More information

Blower Motor 3P Connector

Blower Motor 3P Connector 1. Scope Blower Motor P Connector 1.1 Content This specification covers the requirements for product performance, test methods and quality assurance provisions of Blower Motor P connector. Applicable product

More information

PERFORMANCE SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET INCH-POUND MIL-PRF-64266/21 w/ AMENDMENT 1 1 December 2014 MIL-PRF-64266/21 6 November 2013 PERFORMANCE SPECIFICATION SHEET CONNECTORS, FIBER OPTIC, CIRCULAR, PLUG AND RECEPTACLE STYLE, MULTIPLE REMOVABLE

More information

Parts list and list of drawings

Parts list and list of drawings X-FEL Coupler Doc. Ref. : XFEL/05/01/MEM05/V2 Page : 1/7 Parts list and list of drawings Version n 2 Version n 1 on 30/03/05 on 28/02/05 Writed by : A. Gonnin Checked by : S. Prat On 30/11/04 On 25/03/05

More information

www. ElectricalPartManuals. com Flexitest Switch Assemblies Type FT-19R and FT-19RX INTL APPLICATION

www. ElectricalPartManuals. com Flexitest Switch Assemblies Type FT-19R and FT-19RX INTL APPLICATION Effective: January 2004 Supersedes, dated June 1998 APPLICATION QUALITY FEATURES Descriptive Bulletin 41-078INTL Flexitest Switch Assemblies Type The type FT-19R (standard length) and FT-19RX (extended

More information

Miniature Toggle Switches

Miniature Toggle Switches E L TCT IP PUSH BUTT SLIE ROCKER TOGGLE INEX SPECIFICTIS CTCT RTING: @ VC or VC (Q contact) ELECTRICL LIFE:0,000 make-and-break cycles at full load CTCT RESISTNCE: 0 m max. initial @- VC,00 m INSULTI RESISTNCE:,000

More information

Pressure transmitters for industrial applications MBS 32 and MBS 33

Pressure transmitters for industrial applications MBS 32 and MBS 33 Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer

More information

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER ISOCON-6 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting

More information

HiPace 300 with TC 400, DN 100 CF-F

HiPace 300 with TC 400, DN 100 CF-F HiPace 300 with TC 400, DN 100 CF-F HiPace 300 with TC 400, DN 100 CF-F Similar Image Rugged, powerful turbopump with a pumping speed of up to 260 l/s for N 2 Integrated TC 400 drive electronics Ideal

More information

MS/Standard how to order

MS/Standard how to order /tandard how to order I--5015 and I-5015 ype (older ontacts) 102 18 W () 1 2 5 7 8 1. onnector ype designates ilitary tandard * designates service class and with proprietary special * designates service

More information

ODU AMC. ODU Advanced Military Connector. Clarke & Severn Electronics Ph

ODU AMC. ODU Advanced Military Connector. Clarke & Severn Electronics Ph ODU Advanced Military Connector Clarke & Severn Electronics Ph + Email sales@clarke.com.au www.clarke.com.au ODU AMC Advanced Military Connector Applications Defence and security PTT and PRR systems Ruggedized

More information

SERIES 10 ELEKTRISCHE STECKVERBINDER FÜR MEERES- UND MARINETECHNIK HIGH PERFORMANCE UNDERWATER ELECTRICAL CONNECTORS

SERIES 10 ELEKTRISCHE STECKVERBINDER FÜR MEERES- UND MARINETECHNIK HIGH PERFORMANCE UNDERWATER ELECTRICAL CONNECTORS SERIES 0 ELEKTRISHE STEKVERINDER FÜR MEERES- UND MRINETEHNIK HIGH PERFORMNE UNDERWTER ELETRIL ONNETORS Leinestraße D-9 Neumünster Tel. +9 - - 98-0 Fax +9 - - 98 - http://www.gisma-connectors.de E-Mail:

More information

TESA MICROMASTER Electronic Micrometers with Digital Display

TESA MICROMASTER Electronic Micrometers with Digital Display TESA MICROMASTER Electronic Micrometers with Digital Display DIN 86 T1 0,001 0.00005 in Metric/Inch conversion 100 : Ø 6,5 > 100 : Ø 8 With patented TESA capa µ system Measuring span of 0 or 25. Large

More information

Single point load cells

Single point load cells SP4M Single point load cells Special features Maximum capacities: kg 200 kg Aluminum High ratio of minimum verification Offcenter load compensation Shielded connection cable Explosion protection and other

More information

Load Washers. Force. for Forces of 7, kn. F z. Type 9001A A 9081B, 9091B

Load Washers. Force. for Forces of 7, kn. F z. Type 9001A A 9081B, 9091B Force Load Washers for Forces of 7,5... 1 200 kn Type 9001A... 9071A 9081B, 9091B 1-component force sensor for measuring dynamic and quasistatic forces in z direction. F z Calibrated measuring range 100

More information

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C ASH & ALAIN INDIA PVT LTD S-00, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-000(India) Tel : 0-797575 Fax : 0-79757 E-mail : sales@ashalain.com Proximity Ideal for High Temperatures and Cleaning

More information

ø6, ø10, ø15, ø20, ø25, ø32, ø40, ø50, ø63 How to Order Switch rail Nil Standard stroke Refer to page 12 for standard stroke.

ø6, ø10, ø15, ø20, ø25, ø32, ø40, ø50, ø63 How to Order Switch rail Nil Standard stroke Refer to page 12 for standard stroke. Magnetically Coupled Rodless Cylinder: Direct Mount ype Series ø, ø, ø, ø, ø, ø, ø, ø0, ø Direct mount type mm mm mm mm mm mm mm 0 0 mm mm 00 MB Piping type Both sides piping type Centralized piping type

More information

3M HDC Socket.100 Right Angle, PCB, 3 or 4-Row, Solder Tail or Press-Fit HDC Series

3M HDC Socket.100 Right Angle, PCB, 3 or 4-Row, Solder Tail or Press-Fit HDC Series M HDC Socket.100 Right Angle, PCB, or 4-Row, Solder Tail or Press-Fit HDC Series High density -row version, up to 240 contacts single bay Mates with -row single plugs and headers High density 4-row version,

More information

Nickel-Plated Brass Push-In Fittings - NPTF/INCH

Nickel-Plated Brass Push-In Fittings - NPTF/INCH /INCH Tube Connections: External /8, 5/32, /4, 5/6, 3/8, /2 Thread Connections 0-32 UNF, /8, /4, 3/8, /2 Reusable thread seal, PTFE seal ring (Teflon ) - Pro-Fit Standard - Camozzi s all metal fittings

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

ORTHOBLOC 3000 Drive systems Maintenance

ORTHOBLOC 3000 Drive systems Maintenance 15 en 284 261 282 113 130 120 061 002 264 193 099 001 25 063 65 119 112 133 252 254 1 115 118 04 ORTHOBLOC 3000 Maintenance NOTE LEROY-SOMER reserves the right to modify the characteristics of its products

More information