ULTRA OVAL METER SIZES:29, 60, 31, 32, 33 (Single-case Construction) Register Types A, B, and D
|
|
- Lorin Mosley
- 6 years ago
- Views:
Transcription
1 UT OV METE SIZES:9, 60,,, (Singlecase Construction) egister Types, B, and GENE SPECIICTION GS.No. GENE Our workhorse P flowmeter series is redesigned in this UT OV with the most advanced multifunction electronic register (UT register) capable of indicating the instantaneous flowrate and total flow on an easytoread C and of providing the pulse and output. Significantly improved performance along with compact and lightweight design are among the many benefits it offers. ETUES. Systematic arrangement of pressure rating and temperature range for each model has been restructured.. Microprocessorbased UT register indicates variablestotal flow, both resettable and cumulative, instantaneous flowrate, selectable with mode select switch, plus alarm (low battery alarm) on the C.. Output signal is available in two channels simultaneously in the form of total flow (/0m C factored or unfactored current pulses) and instantaneous flowrate signal ( 0mC analog).. complete series of explosionproof models also available. 5. We also manufacture models approved for applicable highpressure gas control law. 6. With batch controller equipped UT register, you can simply and readily a batch control system. Meter size: 9 Meter sizes:, Meter sizes: 60, GENE SPECIICTIONS Meter Body Item escription Meter size 9 60 Nominal size, mm 0 ( ) 00 ( ) 50 (6 ), 00 ( ) 00 ( ), 50 (6 ) 00 ( ), 50 (6 ) Construction Singlecase construction, pocketless design pplicable fluid Water, petroleums, liquid foods, chemical liquids in general, etc. low range See flow range table (page ). Operating temp. ± 0.5% 0 to +0 C range inearity ± 0.5% 0 to + 60 C inearity ± 0.5% or ± 0.5% epeatability ± 0.05% or ± 0.0% Body SCS Materials otors SUS6 or SUS6 Bearings Carbon bearings or ceramic bearings low direction ight eft (std.), eft ight, Bottom Top, Top Bottom lange atings and Max. Operating Pressures: MPa Pressure ating 0K lange ating JIS 0K lange ating SME, JPI 0K..7 0K Note : eference temperature; 0 C 50 Special Head Office (Tokyo): Tel ax International Sales ivision SK0@oval.co.jp Overseas Branch Offices: Beijing, Seoul, Singapore, Taipei
2 UT OV Meter sizes: 9 to (Single Case) egister Specifications Item Meter size ocal Cumulative totalizing counter display eset counter, 7digits C mode (C) Instantaneous b mode ( ) flowrate (5 digits) b mode None nalog Type Current Pulse (, 5) Pulse width Unit of scaled pulse Type Open Pulse Pulse width collector (, 5) Unit of scaled pulse Type Voltage Pulse (, 5) Pulse width Unit of scaled pulse Without output signal Output signal Power supply Transmission cable With output signal Transmission length wire system Transmission wire system lines wire system mbient temperature Explosionproof configuration pplicable EU directive pplicable EN directive egree of Protection for enclosure Material for housing inish Nominal Meter actors 9 escription 0.00 m (std.) 0.0 m, 0. m 0.0 m /h (std.) m /min (std.) ocal C only to 0mC efer to diagram, page 5. Scaled or unscaled: 0/=/0 mc Scaled: ms ( std. ), 50 ms Unscaled: ms Same as of C counter Scaled or unscaled: Max. V: 0 VC Scaled: ms ( std. ), 50 ms Unscaled: ms 60,,, 0.00 m (std.) 0.0 m, 0. m 0. m /h (std.) 0.00 m /min (std.) allowable current: 50 m Same as of C counter ( ) Scaled or unscaled: 0/= VC Max./7VC Min. Scaled: ms ( std. ), 50 ms Unscaled: ms Same as of C counter ( ) Installed lithium battery ife: years ( years with explosionproof construction and ) External power source: to 5 VC (nalog or current pulse) to VC (Open collector pulse or voltage pulse) to 5 VC (Combination analog and current pulse) Current consumption: Max. 0 mc efer to diagram, page 6. ( ) Capture cable w/external shield (VCT.5 mm, finished O...5 to mm) ( ) Max. km nalog or current pulse Open collector or voltage pulse nalog + current pulse 0 to +60 C (Explosionproof model: 0 to +55 C) (Without dew condensation) Select either one from following two Nonexplosionproof type TIIS Exd B T / Exia B T, Exia B T ( 6) NEPSI Exd B T TEX G Exd B T IP66 (usttight/watertight Type)IEC/EN6059, JIS C 090 luminum die casting Munsell No..5PB5/ baked : If factored pulse units other than above are required, consult the factory. : Battery powered register features a local indicator alone; output signal is not available. : or wiring of explosionproof type, do not fail to use the ancillary pressureresistant packing. lso, in case of TIIS explosionproof type used under the ambient temperature of 5 or higher, use a cable resistant to the temperature of 75 or higher. : Under certain circumstances, the max. flowrate may have limitations if the minimum factored pulse unit is chosen and the pulse width exceeds msec. If this problem arises, consult the factory. 5: If the minimum factored pulse unit is chosen with the capacity indicated by an asterisk, pulse width other than ms is NOT selectable. 6: Explosionproof configuration of UT OV register with batch control function. 7: etails as 9/9/EC compliant explosionproof equipment pplicable hazardous area Zone and Zone EMC 00 / 0 / EC TEX 9 / 9 / EC ( 7) PE 97 / / EC ( ) : s the application to 97/9/EC (Pressurizing instrument order) is dependent on the condition of use, please contact OV representative. Meter Size Nominal meter factor (m/p) req. at max. flowrate (Hz) Max. flowrate (m /h) Pulse (P/rev.) ( ) M Class I, ivision I / Group C, T Ex / Exd B T KOSH Exd B T EMC EN550 : 99 / : 999 Group, Class B EN60006 : 999 TEX EN : 006, EN60079 : 007
3 UT OV Meter sizes: 9 to (Single Case) OW NGES Table low ange for iquid in General (inearity : ±0.5%) (Operating temp. range : 0 to +0 C) Unit in m /h Type of iquid Water iquids other than water 60 C max. 60 C to ess than 0. to 0. to to 5 to 000 to 500 to 0 C 0.mPa s 0.mPa s mpa s 5mPa s 000mPa s 500mPa s 000mPa s Continuous to 0 0 to 5 5 to 50 0 to 50 to 50 6 to 70 to 70 to 60 to Intermittent to 60 0 to 0 5 to 70 0 to 70 to 70 6 to 90 to 90 to 77 to 70.I Continuous 5 to 75 0 to 60 0 to 5 0 to 5 5 to 5 to 0 5 to 0 5 to 0 5 to Intermittent 5 to 0 0 to 75 0 to 5 0 to 5 5 to 5 to 50 5 to 50 5 to 5 5 to 5.I Meter Size Nom. size mm Temp. Viscosity ange Operating Condition Continuous 5 to 0 0 to 90 0 to 0 0 to 0 5 to 0 6 to 0 0 to 0 0 to 50 5 to 0 50 Intermittent 5 to 60 0 to 0 0 to 90 0 to 90 5 to 90 6 to 0 0 to 0 0 to 95 5 to I Continuous 5 to 60 0 to 0 60 to 0 0 to 0 0 to 0 5 to 60 5 to 60 5 to 0 5 to Intermittent 5 to 0 0 to to 70 0 to 70 0 to 70 5 to 0 5 to 0 5 to 75 5 to 5 50.I Continuous 0 to 0 50 to 0 0 to to 50 0 to 50 0 to 60 0 to 60 0 to 05 0 to 0 00 Intermittent 0 to 0 50 to 0 0 to 0 50 to 0 0 to 0 0 to 50 0 to 50 0 to 5 0 to I Table B Meter Size Nom. size mm Type of iquid Temp. Viscosity ange Operating Condition low ange for iquid in General (inearity : ±0.5%) (Operating temp. range : 0 to +60 C) Water iquids other than water Unit in m /h 60 Cmax. ess than 0.mPa s 0. to 0. mpa s 0. to mpa s to 5 mpa s 5 to 000 mpa s 000 to 500 mpa s 500 to 000 mpa s Continuous 5 to 0 to 50 5 to 50 to 50 9 to 70 6 to 70 6 to 60 6 to Intermittent 5 to 60 to 70 5 to 70 to 70 9 to 90 6 to 90 6 to 77 6 to 70.I Continuous 5 to 75 5 to 5 0 to 5 5 to 5 to 0 to 0 to 0 to Intermittent 5 to 0 5 to 5 0 to 5 5 to 5 to 50 to 50 to 5 to 5.I Continuous 0 to 0 60 to 0 0 to 0 5 to 0 5 to 0 5 to 0 5 to 50 5 to 0 50 Intermittent 0 to to 90 0 to 90 5 to 90 5 to 0 5 to 0 5 to 95 5 to I Continuous 50 to to 0 60 to 0 50 to 0 5 to 60 0 to 60 0 to 0 0 to Intermittent 55 to 0 90 to to to 70 5 to 0 0 to 0 0 to 75 0 to 5 50.I Continuous 60 to 0 0 to 50 0 to to to 60 0 to 60 0 to 05 0 to 0 00 Intermittent 60 to 0 0 to 0 0 to 0 70 to 0 50 to 50 0 to 50 0 to 5 0 to I In the Operating Condition column Continuous means continuous operation; Intermittent means no more than hours operation a day, and.i.. indicates allowable instantaneous flowrate. low range should be selected within the Continuous or Intermittent range specified. or applications where viscosity exceeds 00mPa s, specially machined rotors are used. egarding special chemical liquid (liquid ammonia, nitric acid, ammonium sulfate, chlorosulfonic acid, fuming sulfuric acid, sulfuric acid) and highly viscous liquids in excess of 000mPa s, consult factory. egarding liquid ammonia, consult factory. Special
4 OV MOE E000 UT OV Meter sizes: 9 to (Single Case) METE EOS and PESSUE OSSES Error (%) Gasoline 0.mPa s Water mpa s Gas oil mpa s uel oil mpa s Pressure oss (kpa) 0 Meter size lowrate (m /h) Note: Pressure loss varies more or less depending on the meter size. HOOKUP WITH ECEIVING INSTUMENTS eceiving instruments UT OV Totalizer (E0) Batch controller (E series) Pulse divider (SU0) Valve control output Open MOSET Scaled pulse (current, open collector, voltage) Totalizer (E0) Unscaled pulse (current, open collector, voltage) nalog ( to 0mC) Converter, Compensator (E0 ) low computer (E00 series) nalog output Pulse output Pulse output Power supply unit (SU50) ecorder NOTE: Typical examples are shown here. Many other receving instruments are acceptable.
5 UT OV Meter sizes: 9 to (Single Case) WIING CONNECTIONS () Current pulse output (wire system ) ( ) nalog output (wire system) Terminal block V Terminal block SIG 0V G VC Below 600Ω Terminal block V SIG 0V VC Below 600Ω + + to 5VC Power supply nalog indicator Terminal block Oval receiving instrument Oval receiving instrument NOTE: OV offers two circuit configurations to accept current pulses as shown above. See the respective instruction manual of receiving instrument for correct connections. () Current pulse and nalog output (wire system) Tie point G oad resistor Power supply Minimum electrical capacity 60m Totalizer to 5VC nalog indicator : Select voltage signal input for the totalizer. Make sure of the trigger level of incoming voltage signal and determine the supply voltage and load resistance value. In case of current input NOTE: To accept a voltage signal, couple an external load rasistor (see acceptable load resistance range on page 6). NOTE : In an OV receiving instrument, an internal load resistor plays the role of I/V conversion. But if you build a system like the one shown here with a commercially available totalizer, a combination /0m x load resistance serves as a current pulse/voltage pulse converter, make sure of the input level of the totalizer before use. NOTE : With a configuration like the one shown here where an OV receiving instrument is used, make sure of the current carrying capacity of receiving instrument s power supply before use. If found inadequate in current carrying capacity, prepare an additional power supply for the analog indicator. () Open collector pulse (wire system) (5) Voltage pulse (wire system) Terminal block to VC V SIG 0V Max. 50m E ( 0VC) Select so that the allowable current be 50m max. Constant voltage kω Terminal block V SIG 0V to VC Over 0kΩ ms (std.) or 50ms ms (std.) or 50ms Min.7V Max.V ange of oad esistance (for current pulse and analog output) This instrument uses a twowire transmission line for analog and pulse signals, so the line serves for both power supply and signal. C power supply is required for transmission loop. When connecting a meter to the loop, ensure that the meter and the load resistance of cable conductor is within the operating limits shown in the figure at right. Standard: Power supply voltage = VC oad resistance = 50Ω oad resistance (Ω) 660 (600) Operating range () 5 Power supply voltage (V C)
6 UT OV Meter sizes: 9 to (Single Case) OUTINE IMENSIONS (Standard register type provided) [Unit in mm] Meter size: 9 6 Meter size: TEX M0 M NPT TEX and M explosionproof Conduit Connection G/ (female) lange ating JIS 0K JIS 0K Press. ating imensions SME/JPI K pprox. Weight 0K:0.5kg 0K:.5kg 0K TEX M0 M NPT TEX and M explosionproof Conduit Connection G/ (female) pprox. Weight 0K:5kg 0K:90kg Press. ating imensions 0K 0K lange ating JIS 0K JIS 0K SME/JPI or batch controller equipped UT register, refer to General Specification (No. GBC0E). or models provided with auto temperature compensator equipped UT register, consult the factory.
7 UT OV Meter sizes: 9 to (Single Case) OUTINE IMENSIONS (Standard register type provided) [Unit in mm] Meter size: TEX M0 M NPT TEX and M explosionproof Conduit Connection G/ (female) pprox. Weight 0K: 50kg 0K: 55kg Press. ating imensions 0K 0K lange ating JIS 0K JIS 0K SME/JPI Meter size: 00 TEX M0 M NPT 90 TEX and M explosionproof Conduit Connection G/ (female) pprox. Weight : 600kg Press. ating imensions 0K lange ating JIS 0K 00, SME/JPI
8 UT OV Meter sizes: 9 to (Single Case) OUTINE IMENSIONS (Standard register type provided) [Unit in mm] Meter size: 00 TEX M0 M NPT TEX and M explosionproof Conduit Connection G/ (female) pprox. Weight : 50kg Press. ating imensions 0K lange ating JIS 0K SME/JPI or batch controller equipped UT register, refer to General Specification (No. GBC0E). or models provided with auto temperature compensator equipped UT register, consult the factory.
9 UT OV Meter sizes: 9 to (Single Case) POUCT COE EXPNTION Main code Exproof temp. class Explosionproof Process connection Major material Temp. category luid category Nominal diameter Capacity (Nominal iameter) Model Main code egulations egister Power supply Output Version code Bearing Viscosity category Seal material Special / / / dditional code Model U S UT OV (integral type) Single case all stainless 5 Capacity (Nominal iameter) 9 0mm (") N (Small) mm (") N (Big) 00mm or 50mm (" or 6") N (Small (special) or Big) 50mm or 00mm (6" or ") N (Small (special) or Big) 50mm or 00mm (6" or ") N (Small (special) or Big) 6 Nominal diameter Nominal diameter (Small) (Special) Nominal diameter (Big) integral type 7 luid category iquid 9 Temp. category 0 60 and lower Over 60 up to 0 0 Major material C S Z SCS (SUS6) SCS6 (SUS6) Special Process connection J JIS0K J JIS0K Z 9 Special Explosionproof 0 Nonexplosionproof TIIS 5 TEX 6 M 7 NEPSI KOSH T ITI 5 Exproof temp. class 0 Nonexplosionproof T T 6 egulations 0 Standard G High Pressure Gas Safety ct (pproved product) w/material test certificate H J High Pressure Gas Safety ct (Individual test) High Pressure Gas Safety ct (Completion inspection) Gas Business ct (pproved product) w/material test certificate (esigned on PO issued) w/material test certificate w/material test certificate (esigned on PO issued) M Gas Business ct w/material test certificate Q Electricity Business ct (Certificate required) w/material test certificate (esigned on PO issued) Electricity Business ct w/material test certificate T ire Service ct w/material test certificate Z Nuclear power w/material test certificate Special : When register code is "", selectable. : When register code is ", B", selectable. : See General Specification Sheet No. GBC0 for detail. : Consult with OV. 5: When register code is "B", selectable. w/material test certificate (esigned on PO issued) 7 egister Standard UT register B Batch controller equipped UT register (W7E/W76E) uto temp. compensator equipped UT register 9 Power supply 0 External power supply (standard) V Battery drive 0 Output G Standard output (open collector pulse output) nalog Current pulse B Voltage pulse T Current pulse + analog N No output (w/battery unit) Pneumatic step open and close (w/w76e register) 5 Z Special Version code Version code: Bearing 0 Standard (carbon bearing) Standard (strong alkali carbon) Polymerizing liquid (carbon bearing) 5 Hydrogen peroxide solution (ceramic bearing) 6 Highly corrosive polymerizing liquid (ceramic bearing) 7 Polymerizing liquid (carbon bearing) Viscosity category 5 Below 00mPa s (sintered rotors inapplicable) cut rotor 6 00mPa s and over (sintered rotors inapplicable) special cut cut rotor Seal material Oring (PM), gasket (T#0) C Oring (II), gasket (T#0) T Oring (PTE), gasket (V700) P Oring (PTE), gasket (V705) Z Special Special 0 Standard Z Special 9
10 UT OV Meter sizes: 9 to (Single Case) POUCT COE EXPNTION Exproof temp. class Explosionproof Process connection Major material Temp. category luid category Nominal diameter Capacity (Nominal iameter) Model Main code egulations egister Power supply Output Version code Bearing Viscosity category Seal material Special / / / dditional code dditional code Category of High Pressure Gas H P 0 Other than High Pressure Gas H P Toxic gas and flammable gas H P Toxic gas H P lammable gas H P Other than toxic or flammable gas ccuracy 0 5 ±0.50% CCUCY 0 ±0.5% INEITY Only for export 0 ±0.5% INEITY Only for export 0 ±0.0% CCUCY 9 9 Special Operating condition C 0 Continuous M 0 Intermittent Special test (instrumental error) 0 Taxed custody transfer 0 By certified measurer 6 0 Standard oil meter ccording to JMI standard (Bore size 0mm and over) 7 0 Std. fuel oil meter, std. water meter 0 Std. fuel oil meter, std. water meter 9 9 esignation of instrumental error test method ddition of one () test point, etc. low direction 0 0 U 0 T B: Electric conduit at the bottom 0 B T: Electric conduit at the bottom esignated special paint on body B C 0 Corrosion proof B 0 Salinity and acid tolerance 0 and lower B X 0 Customer designation esignated special paint on transmitter S 0 Corrosion proof Special treatment S 0 Salinity tolerance S E 0 cid tolerance Special treatment S X 0 Customer designated paint Special treatment Cleansing T W 0 Nonoil and nonwater treatment T W Nonoil and nonwater treatment equivalent T 0 ood cleansing T 0 Nuclear cleansing T C 0 CIP Choose countermeasure to sudden temp. change abel N P J abel (Japanese) N P E abel (English) ocument S J WG and specifications for approval (Japanese) S E WG and specifications for approval (English) 0 esubmission of WG with specifications C J inal WG (Japanese) C E inal WG (English) P J Calculation sheet (Japanese) P E Calculation sheet (English) S E J Instrumental error test report (Japanese) S E E Instrumental error test report (English) S T J Pressure test report (Japanese) S T E Pressure test report (English) S J irtight test report (Japanese) S E irtight test report (English) J imensional check record (Japanese) E imensional check record (English) S P J Penetrant test report (Japanese) S P E Penetrant test report (English) S M J Magnetic particle inspection (Japanese) S M E Magnetic particle inspection (English) S J adiographic inspection (Japanese) S E adiographic inspection (English) S U J Ultrasonic inspection (Japanese) S U E Ultrasonic inspection (English) S X J PMI test report (Japanese) S X E PMI test report (English) S S J Impact test report (Japanese) S S E Impact test report (English) Y J WPS/PQ (Japanese) Y E WPS/PQ (English) 9 J Photo (Japanese) 9 E Photo (English) T J Inspection procedure (Japanese) T E Inspection procedure (English) C J Inspection certificate: set Only Japanese C B J Inspection certificate: B set Only Japanese C C J Inspection certificate: C set Only Japanese C J Inspection certificate: set Only Japanese Witnessed by customer V 0 equired 0
11 UT OV Meter sizes: 9 to (Single Case)
12 UT OV Meter sizes: 9 to (Single Case) OPETING PECUTIONS This flowmeter is not provided with subtract function. If pulsation in the flow (where the fluid moves back and forth in the pipeline under the influence of pressure) or reversal of flow exists, the total counter may show erratic reading, accumulating all incoming pulses irrespective of flow direction. OEING INOMTION Please complete the following form when making inquiries.. Model. luid to be measured Name Viscosity mpa s Specific gravity. lowrate (m /h) Maximum Normal Minimum. luid temperature ( C) Maximum Normal Minimum 5. mbient temperature ( C) Maximum Normal Minimum 6. Pressure (MPa) Maximum Normal Minimum 7. low direction ight eft, Bottom Top. lange connection Nominal size mm lange rating 9. equired inearity % 0. Explosionproof configuration equired class Not required. ccessories Strainer ir eliminator Companion flange. Quantity Including accessories. eceiving instrument Type, manufacturer, model, specifications (input, output, power supply, etc.). istance between flow meter and receiving device m The specification as of pril, 07 is stated in this GS Sheet. Specifications and design are subject to change without notice. Sales epresentative: GS.No.GBU00E 初版改訂印刷
( Single Case Construction )
OVL FLOWMETER Meter Size:,,,, ( Single ase onstruction ) Pocketless Design GENERL SPEIFITION GS.No.GBB--E GENERL The OVL flowmeter is a positive displacement type flowmeter comprising a pair of oval gear
More informationULTRA OVAL Meter Sizes:39, 41, 45, 50, 52, 53 w/unfactored Pulse Generator (NPG60A)
ULTRA OVAL Meter Sizes:9, 4, 45, 50, 5, 5 w/unfactored Pulse Generator (NPG60A) GENERAL SPECIFICATION GS.No.GBU0--E GENERAL ULTRA OVAL MODEL 9, 4, and45 provides extensive capability as a highly dependable
More informationMODEL : TX Series (Nom. sizes 15mm to 400mm)
iquid High performance and wide viscosity range EX TURBINE MODE : TX Series (Nom. sizes 15mm to 4mm) GENERA EX TURBINE is an industrial turbine meter for consistent and accurate liquid flow measurement.
More informationMODEL: CR002, CR003, CR004. ADC12 Display shield. Liquid (Density range: 0.3 to 2.0g/mL) Operating temperature range
Liquid Inexpensive Microflow Coriolis Flowmeter CoriMate Ⅱ MODEL: CR002, CR003, CR004 GENERAL Based on the knowledge and experience on Coriolis technologies OVAL has gained over many years, the Corimate
More informationDELTA FLOWMETER FOR GAS SERVICE (INSERTION TYPE) MODEL VF SERIES
DETA FOWMETER FOR GAS SERVICE (INSERTION TYPE) MODE VF SERIES GENERA SPECIFICATION GS. No. GBD0-0-E GENERA In the thermistor type Delta meter, a probe inserted in the pipeline detects the representative
More informationMX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E
OMPT ND USER FRIENDLY MX Series Metal Tube Type Variable rea Flowmeter OUTLINE MX Series flowmeter is the metal tube type variable area flowmeter having the unified face-to-face dimension. The compact
More informationApplicable Fluid. Accuracy. Flow Rate Range. Fluid Temperature. Fluid Viscosity. Connection Size. Flange Rating. Housing. Material. Blade.
TOKICO TURINE METER GS-F211E- Overview Turbine meter has an excellent performance with its distinctive structure. Comparing with the flow meter using other method, it has compact and lighter design and
More informationK Series SIGHT GLASS FOR CONVENIENT OBSERVATION OF LIQUID FLOW GENERAL
FOR CONVENIENT OBSERVATION OF IQUID FOW K Series SIGHT GASS GENERA K series are sight glasses for observation of various liquids. Different types are available to meet applications and requirements. Cast
More informationTF-1000 Series MINI THERMAL MASS FLOWMETER PERFECT LINE-UP, BEST COST PERFORMANCE OUTLOOK FEATURES OPERATION PRINCIPLE PRODUCT LINE-UP
PERECT INE-UP, EST COST PERORMNCE T-000 Series MINI TERM MSS OWMETER OUTOOK T-000 MINI TERM MSS OWMETERS are designed and developed to offer the remote indication and control of gas flow process where
More informationPressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27
Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for
More informationAM-1000 Series COMPACT FLOWMETER
METAL TUBE VARIABLE AREA FLOWMETER AM0 Series COMPACT FLOWMETER GENERAL AM0 series are most well accepted metal tube flowmeters which have been developed based on the long time experience of TOKYO KEISO
More informationElectromagnetic Flowmeter
Overview Flokal B.V. smart electromagnetic flow meter is hallmarked by its high performance and reliability that are based on successful, field-proven technology. It s being widely used in industries such
More informationPHOENIX CONTACT - 04/2016. Features
Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.
More informationOperating Instructions for Digital Manometer. Model: MAN-SD
Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5
More informationAM-1000 Series COMPACT FLOWMETER
METAL TUBE VARIABLE AREA FLOWMETER AM0 Series COMPACT FLOWMETER GENERAL AM0 series are most well accepted metal tube flowmeters which have been developed based on the long time experience of TOKYO KEISO
More informationNumber of poles 1-pole 2-pole Minimum Enclosure Contact G2R-1A-E G2R-1-E
The Best Seller eneral purpose power elays of single-pole0 A and double-pole A. Safety-oriented design with dielectric strength of,000 V between coil and contacts, and surge resistance of 0,000 V. and
More informationTransmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level
Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level
More informationPressure transmitters for industrial applications MBS 32 and MBS 33
Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer
More informationVORTEX FLOWMETER (DELTA FLOWPET)
VORTEX FOWMETER (DETA FOWPET) DATA SHEET FMR, M This instrument is a Karman vortex flowmeter capable of measuring the flow rate of liquid, gas, and vapor. The heavyduty detecting section made of stainless
More informationSECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:
SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine
More informationIts modular concept allows to build up a ball valve for any degree of automation and any kind of application
Type 2657...59 DN 10 up to 80 mm; Plastic; 2/2 way dvantages/benefits ntegrated pilot valves, position feed-back and limit switches available Customized system solutions with Burkert valves & sensors With
More informationPilot operated 2 port solenoid valve (general purpose valve) Standard specifications NC (normally closed) type C C. 2 /s) Starting
21/22 Series (general purpose valve) 21/22 Series NC (normally closed) type, NO (normally open) type Port size: Rc1 1/4 to Rc2, 32 to 50 flange iaphragm structure JIS symbol 21: Common specifications Item
More informationTurbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas
Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement
More informationAM7000 Series GENERAL FEATURES METAL TUBE VARIABLE AREA FLOWMETER
MET TUBE VRIBE RE FOWMETER M000 Series GENER The metal tube variable area flowmeter M000 Series has been developed from M-0 Series which were based on the long time experience of TOKYO KEISO in the field
More informationField IT 50T Series Transmitters
Data Sheet SS/G/A_ Field IT 0T Series Transmitters gauge/absolute pressure transmitter Ranges: -00 to 0000kPa - to 00bar -. to 6000psi Base accuracy : 0.% (BFSL) Chemical Vapour Deposition (CVD) technology
More informationCALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%
ATEX documenting multifunction calibrator with high accuracy 0.006% is the top instrument of our range of ATEX documenting multifunction calibrators. Description is the top instrument of our range of ATEX
More informationCALYS 80P. Field pressure calibrator with high accuracy 0.01%
Field pressure calibrator with high accuracy 0.01% CALYS 80P is a field pressure calibrator within CALYS range with high accuracy of 0.01%. Description CALYS 80P is a field pressure calibrator within CALYS
More informationED 701 General Industry Pressure Transmitter
ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationPTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30
eries Features Best pressure transmission solution for small and middle sized project such as indoor heating and air conditioning, water and sewer, or incinerator, etc. Improves noise resistance and minimize
More informationDMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm
DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up
More informationSingle Phase Motors Technical Datasheets
Single Phase Motors Technical Datasheets EN A dynamic, strong and ambitious Group: Orange1 Holding is an international renown Group, one of the most important European manufacturers of single-phase and
More informationAC axial compact fan
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8-0 Fax +9 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of registration)
More informationE8EB-N0C2B E8EB-N0B2B
Slim Sensor CSM DS_E 1 Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree
More informationCoriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM
MAXIFO TM Features MaxiFlo Coriolis Mass Flowmeter series MCM is a mass flow meter that measures mass flow, density and temperature of liquids, slurries and gases. And it even measures oil content in water.
More informationFitting PS P - B - R2
INTERNAL STRUCTURE PS86 (G 3/8) 2 3 FEATURES Solidstate pressure switch with no mechanical moving parts Isolated output via a photo-coupler Switching pressure adjustable and hysteresis band adjustable
More informationST3000 Series 900 Smart Transmitter Differential Pressure Transmitters
No. SS2-STJ100-0100 (Rev.9) ST3000 Series 900 Smart Transmitter Differential Pressure Transmitters Model STD910/STD920/STD930/STD960/STD921/STD931/STD961 OVERVIEW The ST3000 Smart Transmitter is a microprocessor-based
More information14:1400 (0206) KRAL Volumeter - OMG
14:1400 (0206) KRAL Volumeter - OMG OMG - Universal OMG The flowmeter for a wide range of applications Operating Conditions and Materials Flow Range: 0.1 to 7,500 l/min Max. Pressure: 250 bar Temperature
More informationSurface-mounting Thermostats ATH Type Series
Page 1/9 urface-mounting Thermostats ATH eries k enclosure protection IP 54 k tested to IN EN 14597 (replacing IN 3440) Brief description Thermostats control and monitor thermal processes. Instruments
More informationPressure Transmitter ED 701
Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation
More informationDS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.
DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link
More informationVortex Flow Meters. RVL Series Vortex Flow Meter
TM Vortex Meters RVL Series Vortex Meter pplications: Water/Wastewater I Water: Semiconductor, Institutional I Water Skids Semiconductor Equipment Slurry hemical Processing RINE FEERTE IN. ISO 900 : 000
More informationDrive electronics pq12
Drive electronics pq12 Amplifier module with constant current controller for proportional valves Control of one solenoid Easy mounting directly on bearing rails acc. to EN 50022 Standard voltage and current
More informationABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY
ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo 22 36054 Montebello Vicentino (VI) - ITALY www.abb.com/transformercomponents The information contained in this document is for general information
More informationCOMPACT FLOWMETER TO COVER ALL POSSIBLE APPLICATIONS. METAL TUBE AM-1000 Series GENERAL FEATURES TG-F962-0E APR.,2000 AM-1000 COMPACT FLOWMETER
AM0 TO COVER ALL POSSIBLE APPLICATIONS METAL TUBE AM0 Series GENERAL AM0 series are most well accepted metal tube flowmeters which have been developed based on the long time experience of TOKYO KEISO in
More informationAM7000 Series GENERAL FEATURES METAL TUBE VARIABLE AREA FLOWMETER
MET TUBE VRIBE RE FOWMETER M000 Series GENER The metal tube variable area flowmeter M000 Series has been developed from M-0 Series which were based on the long time experience of TOKYO KEISO in the field
More informationE6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders
Multi-turn High-precision Encoder Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders Reset function for easy origin alignment when built-into equipment. Multi-turn
More informationCone differential pressure flow meter. Operating manual WIDE PLUS PRECISION INSTRUMENTS CO., LTD.
Cone differential pressure flow meter Operating manual WIDE PLUS PRECISION INSTRUMENTS CO., LTD. INDEX Introduction 2 Principle Application The characteristics of flow meter Specification Technical features
More informationAbsolute encoders multiturn
elektronischer electronic multiturn, Multiturn, magnetic magnetisch Sendix M66 / M68 (shaft / hollow shaft) The Sendix M6 with Energy Harvesting Technology is an electronic multiturn encoder in miniature
More informationDS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm
Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar
More informationDMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output
More informationRelative pressure transmitter type 520
Relative pressure transmitter type 520 Pressure range The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the pressure measuring cell is fully
More informationDOG-1/-3. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air : 120 C. p max. : PN 40; t max
Oscillation Flowmeter for gases measuring monitoring analysing DOG1/3 Measuring ranges: 0.2 20... 200 20000 m 3 /h air p max : PN 40; t max : 120 C Connection: flange DN 25... DN 400 Material: cast iron,
More informationPressure Measurement Single-range transmitters for general applications
Siemens AG 07 Overview Function SITRANS LH00 Transmitter for hydrostatic level U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationVolumetric Flow Measurement
Volumetric Flow Measurement TVF Series Vortex Flow Meter Xi an Tosilon Automation Co., Ltd No.299, Daqing Rd, Lianhu District, Xi'an Shaanxi, China Tel: +86-29-8823 8550 info@tosilon.com; www.tosilon.com
More informationIntegral V-Cone Flowmeter VD series
TRANSMITTER DIRECTLY MOUNTED! SIMPLE AND EASY INSTALLATION Integral V-Cone Flowmeter VD series OUTLINE VD series Integral V-Cone Flowmeter is a differential pressure type flowmeter. Unlikely to existing
More informationIBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationIBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationOdor Removal Filter. Model Note) 1 8, , , , 3 4. Model/Free Standing Type AMF800. Model/Piping Support Type AMF Port size
dor emoval ilter Series os fficiently can remove odor in compressed air with an activated carbon element. The unit is designed for use in the area such as a clean room where odors must be avoided. Can
More informationUniversal type Port size: M5, Rc1/8, Rc1/4. Max. working. pressure
irect acting port solenoid valve for compressed air, manifold (special purpose valve) Series Universal type Port size: M, Rc/, Rc/ Refer to nding for more details. JIS symbol ommon supply / common exhaust
More informationAC axial compact fan
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8-0 Fax +9 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of registration)
More informationTF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels
TF 0 / TF 0-Ex Field mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.69 EN USA Input Resistance thermometer (,, wire circuit) Thermocouples
More informationINTERNATIONAL OIML D 25 DOCUMENT. Vortex meters used in measuring systems for fluids ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION
INTERNATIONAL OIML D 25 DOCUMENT Edition 1996 (E) Vortex meters used in measuring systems for fluids Compteurs à vortex utilisés dans les ensembles de mesurage de fluides OIML D 25 Edition 1996 (E) ORGANISATION
More informationISEmax CAM40/CAS40. Technical Information
Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works
More informationCORIOLIS MASS FLOW METERS FOR GAS AND LIQUID MEASUREMENT. Michael Keilty (Presented by Hubbard Donald) Endress + Hauser Flowtec AG
Introduction CORIOLIS MASS FLOW METERS FOR GAS AND LIQUID MEASUREMENT Michael Keilty (Presented by Hubbard Donald) Endress + Hauser Flowtec AG A mass flowmeter is a system that provides a measurement of
More information35P-3 HH 3 HH 2 35P-3. f32 f40. f50 f63. f80 f100. Switch Set. Type Standard type Switch Set
f f f f f f Kind of piston seal U seal Slipper Seal U seal Slipper Seal Nominal pressure. MPa Maximum allowable pressure. MPa Proof test pressure MPa Minimum operating pressure. MPa or less Working speed
More informationTF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.
TF / TF -Ex Field mounted temperature transmitters, PROFIBUS PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN P R O F I PROCESS FIELD BUS B U S Input Resistance thermometer (,, -wire
More informationT20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en
T20WN Torque transducers Data Sheet Special features - Nominal (rated) torques 0.1 N m, 0.2 N m, 0. N m, 1 N m, 2 N m, N m, 10 N m, 20 N m, 0 N m, 100 N m, 200 N m - Accuracy class: 0.2 - Contactless transmission
More informationProximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C
ASH & ALAIN INDIA PVT LTD S-00, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-000(India) Tel : 0-797575 Fax : 0-79757 E-mail : sales@ashalain.com Proximity Ideal for High Temperatures and Cleaning
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationGear Wheel Flowmeter for viscous liquids Model DZR. (option 3):
Gear Wheel Flowmeter for viscous liquids measuring monitoring analysing DZR easuring range:. -... 3-7 l/min Accuracy: ±.3... ±1% of reading p max : bar t max : 1 C Orocess O connection: G ⅛, G ⅜, G ½,
More informationAC axial fan. Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of registration)
More information2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50
/way ball valve with electric rotary actuator, ball valve in plastic, N 50 Suitable for aggressive media High flow rate value Actuator with adjustable limit switches Visual position indicator Type 0 can
More informationT h e rm i s t o r s
Data Pack E Issued March 00 - T h e rm i s t o r s NTC thermistors The R S range of NTC thermistors includes standard tolerance negative temperature coefficient thermistors, a range of small close tolerance
More informationHigh-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet
High-efficiency Circulator Pump Rio-Eco N / Rio-Eco Z N Type Series Booklet Legal information/copyright Type Series Booklet Rio-Eco N / Rio-Eco Z N KSB Aktiengesellschaft All rights reserved. The contents
More informationTHE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE
July 04 THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE In this third part. we want to speak about how important is the correct sizing of the
More informationAC axial compact fan
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 798 8-0 Fax +49 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA
More information4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)
4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE) RE 9035/. Replaces: 05. 1/1 Type 4WRPEH 6 Size 6 Unit series X Maximum
More informationIndustrial Pressure Transmitter
ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter
More informationIndustrial Pressure Transmitter
ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter
More informationFLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:
abc instruments international FLT5A Thermometer Land Instruments International Dronfield, S18 1DJ England Telephone: (1246) 417691 Facsimile: (1246) 41585 Email: infrared.sales@landinst.com Internet: www.landinst.com
More informationSTATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016
APPLICATIONS Moisture monitoring of air or gas (SF6) Suitable for indoor or outdoor Industrial, medical or aerospace fields HIGHLIGHTS High voltage circuit breakers commonly used for distribution and transmission
More informationTime - timing relays 1 Industrial relays, solid state output, width 22.5 mm
haracteristics Zelio ime - timing relays Industrial relays, solid state output, width. mm Presentation 08 he E9 range of relays is designed for simple, repetitive applications with short and intensive
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer HO-NSM series I PN = 8, 15, 25 A Ref: HO 8-NSM, HO 15-NSM, HO 25-NSM For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the
More informationAN78xx/AN78xxF Series
3-pin positive output voltage regulator ( type) Overview The N7xx series and the N7xxF series are 3- pin, fixed positive output type monolithic voltage regulators. Stabilized fixed output voltage is obtained
More informationLow Drop Voltage Regulator TLE 4296
Low Drop Voltage Regulator TLE 4296 Features Three versions: 3.0 V, 3.3 V, 5.0 V Output voltage tolerance ±4% Very low drop voltage Output current: 30 ma Inhibit input Low quiescent current consumption
More informationSolenoid valve Types CSV 2 - CSV 22 (NC) and solenoid coil
Data sheet Solenoid valve s CSV 2 - CSV 22 (NC) and solenoid coil CSV is a direct or servo-operated solenoid valve for liquid, suction, and hot gas lines with fluorinated refrigerants. CSV valves are for
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer LDSR 0.3-TP/SP1 I P R N = 300 ma For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Closed
More informationRoHS. Versatile. X g. X 2 e
s IN8, - and The inclinometers of the IN8 series allow measuring inclinations in the range of ±85 or -dimensional inclinations up to 0. With their high robustness, their protection level up to max. IP9k
More information405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook
Reference Manual 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book and Flow Handbook www.rosemount.com Reference Manual 405 and 1595 405 Compact Orifice Series and 1595 Conditioning
More information405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook
405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book and Flow Handbook www.rosemount.com 405 and 1595 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test
More informationv = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes
Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes Examples of Application Flow measurements also in hazardous locations X zone 0 or zone 1 in clean rooms in air
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer HO-NP series I P N = 4, 6, 12, 15 A Ref: HO 4-NP, HO 6-NP, HO 12-NP, HO 15-NP For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary
More informationDIFFERENTIAL PRESSURE (FLOW) TRANSMITTER
DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER DATA SHEET FKC...5 The FCX AIII differential pressure (flow) transmitter accurately measures differential pressure, liquid level, gauge pressure or flow rate and
More informationSITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181
Siemens AG 09 SITRANS F flowmeters System information Overview Siemens offers two types of ultrasonic flowmeters, in-line flowmeters and clamp-on flowmeters. This offers the end user the maximum flexibility
More informationAC axial compact fan
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA 59
More informationNon-Contact Safety Systems CMS
Selection table for non-contact safety system // Evaluation units Connection Desi Read head contact assembly Assured switch-on distance S ao [mm] Assured switch-on distance S ar [mm] Number of outputs
More informationDM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability
DM70 Hand-held Dewpoint Meter Truly Fast Response - Superior Long-term Stability DM70 - When Dry Air Is Important The Vaisala DM70 Hand-held Dewpoint Meter offers stable and fast measurement for industrial
More informationConductivity sensor for hygienic applications
Conductivity sensor for hygienic applications Type 8221 can be combined with Perfect for demanding applications in the hygienic industry (CIP and SIP compatible) Variants available for usage over a wide
More informationFull Metal Variable Area Flow Meter and Counter
Full Metal Variable rea Flow Meter and Counter for horizontal and vertical mounting measuring monitoring analysing Special versions up to 600 bar Measuring range: 10-100...00-000 L/h water 0.3-3.0...-0
More information