Auxiliary Sensors Module

Size: px
Start display at page:

Download "Auxiliary Sensors Module"

Transcription

1 Auxiliary Sensors Module Technical Manual BASM Version 00 BRUKER

2 The information in this manual may be altered without notice. BRUKER accepts no responsibility for actions taken as a result of use of this manual. BRUKER accepts no liability for any mistakes contained in the manual, leading to coincidental damage, whether during installation or operation of the instrument. Unauthorised reproduction of manual contents, without written permission from the publishers, or translation into another language, either in full or in part, is forbidden. This manual was written by P. KRENCKER September, 998: Bruker SA Wissembourg, France Manual P/N: Z80 DWG-Nr: 8 / 00

3 Contents Contents... Description Introduction Description of the BASM BASM front view.... Installation....5 Input connectors... 8 Pt00 connector...9 Thermocouple connector...0 Technical specifications.... W08 (xpt00 inputs).... W08 (xk chromel-alumel inputs).... W08 (xe + xt inputs)... Schematics... 5 Figures... 9 Tables... BASM Version 00 BRUKER ()

4 Contents () BRUKER BASM Version 00

5 Description Introduction. The BASM (Bruker Auxiliary Sensor Module) is an option module for a BVT000 or BVT00 temperature controller unit. The VTU s firmware must be version. or more recent. It is designed for temperature monitoring only, not for sample temperature regulation. It has inputs which can be for Pt00 or thermocouple. The module is mounted on the front panel of the temperature unit. Three modules with different inputs exist : W08 auxiliary sensor module with Pt00. W08 auxiliary sensor module with K thermocouple inputs. W08 auxiliary sensor module with T thermocouple inputs and E thermocouple inputs. Description of the BASM. Figure.. BASM overview CJC CH0 Analog to digital converter mux : CH CH interface CH to microcontroller BASM Version 00 BRUKER 5 ()

6 Description BASM front view. Figure.. BASM front view CH0 CH CH CH module with Pt00 inputs CH0 CH CH CH module with thermocouple inputs Installation. Check that mains is removed from temperature unit. Remove the cover of the temperature unit. Unscrew the small rectangular plate on the front panel and remove also the cover of the module. Insert the module and hold it with screws. Install the cable as shown in figure "Flat cable installation" on page 7. Mount the cover of the module and close the temperature unit. Power on the temperature unit. () BRUKER BASM Version 00

7 Installation Figure.. Flat cable installation cable P/N W098 BASM Version 00 BRUKER 7 ()

8 Description Input connectors.5 For the Pt00 inputs small round LEMO connectors are used. The thermocouple compensated connectors are miniature size and have a shield pin. An adapter cable must be used when connecting a thermocouple with a standard size connector. Table.. Adapter cable list thermocouple type T K E adapter cable W099 W000 W00 Figure.. Adapter cable blue = T violet = E yellow = K color dot 8 () BRUKER BASM Version 00

9 Input connectors Pt00 connector.5. Figure.5. Pt00 connector (front view) Table.. Pt00 connector pin assignment PIN SIGNAL current + measure measure current - BASM Version 00 BRUKER 9 ()

10 Description Thermocouple connector.5. Figure.. Thermocouple connector Table.. Thermocouple connector pin assignment PIN SIGNAL input - frame ground input + 0 () BRUKER BASM Version 00

11 Technical specifications tions W08 (xpt00 inputs). Auxiliary sensor module with Pt00 inputs. Range: -00 C to 800 C. Precision: <±0.5 % of full scale with room C ± C. sensor current: ma. Application: AVANCE spectrometer. Weight: 500 gr. Dimensions: 87 mm (W) x mm (H) x 55 mm (D) aluminium/steel case. Operating temperature: 0to50 C. BASM Version 00 BRUKER ()

12 Technical specifications W08 (xk chromel-alumel inputs). Auxiliary sensor module with K(chromel-alumel) thermocouple inputs. Scale: -00 C to 70 C. Precision: <±0.5 % of full scale with room C ± C. internal CJC (cold junction compensation). small size compensated thermocouple connector with shield pin. Application: EPR spectrometer. Weight: 500 gr. Dimensions: 87 mm (W) x mm (H) x 55 mm (D) aluminium/steel case. Operating temperature: 0to50 C. () BRUKER BASM Version 00

13 W08 (xe + xt inputs) W08 (xe + xt inputs). Auxiliary sensor module with E (chromel-constantan) and T(copper-constantan) thermocouple inputs. Scale T: -00 C to 00 C. Scale E: -00 C to 000 C. Precision: <±0.5 % of full scale with room C ± C. internal CJC(cold junction compensation). E inputs for CH0 and CH. T inputs for CH and CH. small size compensated thermocouple connector with shield pin. Application: AVANCE spectrometer with MAS probe. Weight: 500 gr. Dimensions: 87 mm (W) x mm (H) x 55 mm (D) aluminium/steel case. Operating temperature: 0to50 C. BASM Version 00 BRUKER ()

14 Technical specifications () BRUKER BASM Version 00

15 Schematics BASM Version 00 BRUKER 5 ()

16 () BRUKER BASM Version 00 Figure.. Auxiliary sensors board sheet/ A A -5V ADC_REFOUT C 00N C 00n C 00n C 0u C7 0u A TA TB TC TD X0 X X 5 X Y0 Y 5 Y Y V + G N D 8 V - 7 X Y A 0 B 9 ENA- U 05 SMD A V D D RTD 9 IN+ 7 IN- 8 RTD 0 IN+ 7 A G N D 8 D G N D V S S S Y N C - 5 CLKOUT CLKIN D V D D V B I A S R E F - R E F + 5 R E F O U T DRDY- TFS- 9 RFS- 0 SDATA SCLK A0 MODE U AD77AR PTI DRDY- SDATA TFS- RFS- SCLK A0 X 0 X Y 0 Y Z 0 5 Z I N H A B 0 C 9 X Y 5 Z V C C G N D 8 V S S 7 U 05 SMD C5 00n TYPE A TP7.5V ADC_REFOUT ALIM_RES +5V_PULLUP -5V_PULLDOWN X QUARTZ 0M R.k.5V R8.5k R7 0K TP U LM5CZ S0 S A TA TB TC TD C 00n A C 00n -5V X0 X X 5 X Y0 Y 5 Y Y V + G N D 8 V - 7 X Y A 0 B 9 ENA- U5 05 SMD 0mV / C R 00R R 0R R 0K C0 00n -5V -5V J A0 SDA SDATA SCLK DRDY- TFS- RFS- SCL RST- C7 0u C8 0u A L L TP0 TP C 00n A B QA QB QC 5 QD QE 0 QF QG QH CLEAR- 9 CLK 8 U7 7HC SMD TYPE S0 S ALIM_RES TP8 TP9 JP R9 0K R0 0K SDATA - Extern - Normal TP EXT_SSCLK TP TP5 5 UB 7HC08 SMD TFS- RFS- S0 S PTI PTI PTI PTI PTI C7 00n A C8 00n -5V TP UC 7HC08 SMD A0 UA 7HC08 SMD SCLK R 0K R.7k RST- C 00n C5 0u TST C+ GND C- V+ 8 OSC 7 LV VOUT 5 U8 ICL70CBA TP EXT_SSCLK TP TP TP M C0 0u -5V L C9 0u R0 0R CONVERTER +5v - C5 0u R7 0R R 0K R5 0K SCL SDA 5 A0 A A PTC 7 U9 X0S8 SDA SCL R7 R5 *0K C 00n R LINK S0505.SCH ART: BVTX00 W09 AUXILIARYSENSORS BOARD APPROV: DWG: EC: DATE : DATE : DRAWN : VISA: VISA: SHEET: 0/05/9 WS050 JFP / DP /

17 BASM Version 00 BRUKER 7 () J J C 00n +5V_PULLUP R 0M C 00n L 0u L5 0u C 00n R 0M -5V_PULLDOWN C5 00n C 00n A R8 0M C 00n L 0u L7 0u C 00n R9 0M -5V C7 00n C u 0V C u 0V C u 0V C9 u 0V R 0R R 0R PTI TA TA PTI TB TB R5 0R R 0R UD 7HC08 SMD C 00n C 00n A R0 C 0M J 00n C0 00n R 0M C0 00n C9 00n A R 0M C8 J5 00n C9 00n R 0M C8 00n ART: W09 EC: BVTX00 AUXILIARYSENSORS BOARD L0 L -5V L8 L9-5V 0u 0u 0u 0u DRAWN : DATE : APPROV: DATE : JFP / DP 0/05/9 DWG: WS0505 C5 u 0V C R 0R u 0V C u 0V C7 R 0R u 0V VISA: VISA: SHEET: / PTI TC TC PTI TD TD Figure.. Auxiliary sensors board sheet /

18 Schematics 8 () BRUKER BASM Version 00

19 Figures Description 5 Figure.. BASM overview...5 Figure.. BASM front view... Figure.. Flat cable installation...7 Figure.. Adapter cable...8 Figure.5. Pt00 connector (front view)...9 Figure.. Thermocouple connector...0 Technical specifications Schematics 5 Figure.. Auxiliary sensors board sheet/... Figure.. Auxiliary sensors board sheet /...7 BASM Version 00 BRUKER 9 ()

20 Figures 0 () BRUKER BASM Version 00

21 Tables Description 5 Table.. Adapter cable list... 8 Table.. Pt00 connector pin assignment... 9 Table.. Thermocouple connector pin assignment... 0 Technical specifications Schematics 5 BASM Version 00 BRUKER ()

22 Tables () BRUKER BASM Version 00

23 Lastpage BASM Version 00 BRUKER ()

4" 5*7 Dot Matrix Display Information Board User s Guide

4 5*7 Dot Matrix Display Information Board User s Guide " * Dot Matrix Display Information Board User s Guide 00-00 Sure Electronics Inc. DE-DP0-Ver.0 " * DOT MATRIX DISPLAY INFORMATION BOARD USER S GUIDE Table of contents Chapter. Overview and Main Feature...

More information

1.5 Character Height 7-Segment LED Information Board User s Guide

1.5 Character Height 7-Segment LED Information Board User s Guide . Character Height -Segment LED Information Board User s uide 00-00 Sure Electronics Inc. DE-DP00-Ver.0 . Character Height -Segment LED Information Board User s uide Table of contents Chapter.Overview

More information

Sure Electronics 1.5inch LED Board User s Guide

Sure Electronics 1.5inch LED Board User s Guide Sure Electronics.inch LED Board User s uide Product Name Product ID :.inch Character Height -segment LED Information Board : DE-DP00 Product Version : Ver.0 Document Version : Ver.0 Copyright 00-00 Sure

More information

1.8 Character Height 7-Segment LED Information Board User s Guide

1.8 Character Height 7-Segment LED Information Board User s Guide . Character Height -Segment LD Information Board User s Guide 00-00 Sure lectronics Inc. D-DP00-Ver.0 . Character Height -Segment LD Information Board User s Guide Table of contents Chapter.Overview and

More information

AQX 20 Slot Chassis. AQX MAINFRAME- Manual BRUKER. Version

AQX 20 Slot Chassis. AQX MAINFRAME- Manual BRUKER. Version AQX 0 Slot Chassis AQX MAINFRAME- Manual Version 00 BRUKER The information in this manual may be altered without notice. BRUKER accepts no responsibility for actions taken as a result of use of this manual.

More information

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER ISOCON-6 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting

More information

E2T0 DVP

E2T0 DVP 29-5-26 5116868-E2T DVP-11363-1 ENGLISH Thank you for choosing Delta s DVP series PLC. DVP4TC-E2 temperature measurement module receives 4 points of external thermocouple temperature sensors (J-type, K-type,

More information

BMXART0814 analog input module M340-8 inputs - temperature

BMXART0814 analog input module M340-8 inputs - temperature Characteristics analog input module M340-8 inputs - temperature Complementary Analog/Digital conversion Analogue input resolution Input impedance Permitted overload on inputs Common mode rejection Differential

More information

Using a Mercury itc with thermocouples

Using a Mercury itc with thermocouples Technical Note Mercury Support Using a Mercury itc with thermocouples Abstract and content description This technical note describes how to make accurate and reliable temperature measurements using an

More information

BMXART0814 analog input module M340-8 inputs - temperature

BMXART0814 analog input module M340-8 inputs - temperature Product data sheet Characteristics BMXART0814 analog input module M340-8 inputs - temperature Main Range of product Product or component type Electrical connection Input output isolation Input level Analogue

More information

Respiratory Pressure. Meter Service Manual. Introduction 3. Operation 3. Respiratory Pressure. Meter Layout 4. Cleaning and Maintaining the

Respiratory Pressure. Meter Service Manual. Introduction 3. Operation 3. Respiratory Pressure. Meter Layout 4. Cleaning and Maintaining the Contents page Introduction Operation Respiratory Pressure Meter Layout SNIP MIP / MEP OFF Cleaning and Maintaining the Respiratory Pressure Meter Disassembling the Respiratory Pressure Meter Reassembling

More information

Pushbutton Units and Indicator Lights

Pushbutton Units and Indicator Lights Insert labels and insert caps Clear, illuminated and indicator lights can be fitted with insert labels and caps for identification purposes. These labels and caps are made of a semi-transparent molded

More information

1) Thermo couple sensor

1) Thermo couple sensor 1) Thermo couple sensor Fundamental operation. In 1821 Mr. Seebeck found that if you connected 2 wires of different metals, a small Voltage would be generated, when this connection (junction) is heated.

More information

DATA SHEET. Thermocouple module with digital I²C-Interface - THMOD-I²C. Characteristic features. Areas of application. Features.

DATA SHEET. Thermocouple module with digital I²C-Interface - THMOD-I²C. Characteristic features. Areas of application. Features. Description Characteristic features Industrial temperature measuring method Wide measuring range, -270...+1360 C Digital I²C-interface Simple integration to micro-controller Scope of supply with thermocouple,

More information

Welcome. Functionality and application of RTD Temperature Probes and Thermocouples. Dipl.-Ing. Manfred Schleicher

Welcome. Functionality and application of RTD Temperature Probes and Thermocouples. Dipl.-Ing. Manfred Schleicher Welcome Functionality and application of RTD Temperature Probes and Thermocouples Dipl.-Ing. Manfred Schleicher This presentation informs about the basics of RTD Temperature Probes and thermocouples Functionality

More information

Temperature Scales. Temperature, and Temperature Dependent on Physical Properties. Temperature. Temperature Scale

Temperature Scales. Temperature, and Temperature Dependent on Physical Properties. Temperature. Temperature Scale Temperature Scales The Celsius, Fahrenheit, and Kelvin Temperature Scales: Temperature, and Temperature Dependent on Physical Properties Physics Enhancement Programme Dr. M.H. CHAN, HKBU 9 T F T 5 T T

More information

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER CAUTION: This equipment is designed for connection to mains voltages and must be used in accordance with this guide. If it is not, the safety protection

More information

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol with PROFIBUS-PA procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application 00 II () G FISCO The SINEAX VK 66 is a temperature transducer for use in aumation systems

More information

TM04N- General Description

TM04N- General Description N ( CH Capacitive Touch Sensor Module) N -CH Capacitance Touch Sensor Module with Differential Sensitivity Calibration General Description The N Touch Sensor Module is designed specifically for detecting

More information

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER Model : TM-2000 Your purchase of this THERMOMETER marks a step forward for you into the field of precision measurement. Although this THERMOMETER is a

More information

THERMOCOUPLE CHARACTERISTICS TRAINER

THERMOCOUPLE CHARACTERISTICS TRAINER THERMOCOUPLE CHARACTERISTICS TRAINER (Model No : ) User Manual Version 2.0 Technical Clarification /Suggestion : / Technical Support Division, Vi Microsystems Pvt. Ltd., Plot No :75,Electronics Estate,

More information

ENGR-4300 Fall 2008 Test 3. Name SOLUTION. Section 1(MR 8:00) 2(TF 2:00) (circle one) Question I (20 points) Question II (15 points)

ENGR-4300 Fall 2008 Test 3. Name SOLUTION. Section 1(MR 8:00) 2(TF 2:00) (circle one) Question I (20 points) Question II (15 points) ENGR-4300 Fall 008 Test 3 Name SOLUTION Section (MR 8:00) (TF :00) (circle one) Question I (0 points) Question II (5 points) Question III (0 points) Question I (0 points) Question (5 points) Total (00

More information

DETAIL SPECIFICATION SHEET

DETAIL SPECIFICATION SHEET INCH POUND MIL DTL 28803/1E 1 September 2018 SUPERSEDING MIL D 28803/1E 4 September 2013 DETAIL SPECIFICATION SHEET DISPLAY, OPTOELECTRONIC, SEGMENTED READOUT, BACKLIGHTED, STYLE II (LIGHT EMITTING DIODE),

More information

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR 19 TECHNOLOGY. NET Protector Surge Arrester. Protects switches, HUBs and telecommunication

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR 19 TECHNOLOGY. NET Protector Surge Arrester. Protects switches, HUBs and telecommunication Surge Arrester Protects switches, HUBs and telecommunication systems Class D according to EN 0 possible (Gigabit Ethernet) Variably equippable patch panels Units available with plug-in inputs and outputs

More information

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows: The basic PC software is supplied free with the recorder. There is an additional charge for the extensive Data Acquisition Software supplied with communication of RS-232/422/485 or Ethernet. The Ordering

More information

Lecture 36: Temperatue Measurements

Lecture 36: Temperatue Measurements Lecture 36: Temperatue Measurements Contents Principle of thermocouples Materials for themocouples Cold junction compensation Compensating wires Selection of thermocouples Illustration of gas temperature

More information

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8. TF / TF -Ex Field mounted temperature transmitters, PROFIBUS PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN P R O F I PROCESS FIELD BUS B U S Input Resistance thermometer (,, -wire

More information

S Sapling INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS. advanced time and control systems

S Sapling INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS. advanced time and control systems INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS Time base: 60 Hz (3-wire system) Quartz (2-wire system) Power input: 85 135 VAC / 60 Hz 7 28 VAC / 60 Hz Current consumption:

More information

Community College of Allegheny County Unit 9 Page #1. Thermocouples R1 = 1K

Community College of Allegheny County Unit 9 Page #1. Thermocouples R1 = 1K 10K Community College of Allegheny County Unit 9 Page #1 Thermocouples +12V Thermocouple Junction Vin Copper Wire Constantan Wire + - 3 2 741 7 4 1 5-12V 6 V Vout R1 = 1K Rf = 100K Engineers are not expected

More information

Institut de RadioAstronomie Millimétrique Keywords:

Institut de RadioAstronomie Millimétrique Keywords: -COMP-0 Revision: JAN 00 Francis Morel Institut de RadioAstronomie Millimétrique SubRef VME Board Owner Francis Morel (morel@iram.fr) Keywords: Approved by: Date: Signature: A.Perrigouard December 00 Change

More information

SEN TRONIC AG 1 A 6 6 / "

SEN TRONIC AG 1 A 6 6 / 1A 66/" 0!"#$%&'() %"*+", - %"*.", - /01234%( 34.+*!54%& 0*%/# "6#,7857.'.0" - 6#)9.:. &%&;! 0 &????'.&% )&" 8" @&& (++ '() %('.('/(#$!!! ' %! %!& ;!;8 ;!;8 0 &&'&&;! C;!C&(D"@@ &;! 0&&+%&;! C&=;!C&(D"@@

More information

Sensors and Actuators Sensors Physics

Sensors and Actuators Sensors Physics Sensors and ctuators Sensors Physics Sander Stuijk (s.stuijk@tue.nl) Department of Electrical Engineering Electronic Systems 2 THERMOELECTRIC SENSORS (Chapter 3.9, 16.4) 3 Thermoelectric effect thermoelectric

More information

SCTP20 Programmable 2-Wire Temperature Transmitter, Head Mount

SCTP20 Programmable 2-Wire Temperature Transmitter, Head Mount 20 Programmable 2-Wire Temperature Transmitter, Head Mount Configurable Transmitters Description Each 20 2-wire transmitter is designed for measuring temperature using thermocouples or RTDs. The input

More information

HiPace 300 with TC 400, DN 100 CF-F

HiPace 300 with TC 400, DN 100 CF-F HiPace 300 with TC 400, DN 100 CF-F HiPace 300 with TC 400, DN 100 CF-F Similar Image Rugged, powerful turbopump with a pumping speed of up to 260 l/s for N 2 Integrated TC 400 drive electronics Ideal

More information

HiPace 300 with TC 110, DN 100 CF-F

HiPace 300 with TC 110, DN 100 CF-F HiPace 300 with TC 110, DN 100 CF-F HiPace 300 with TC 110, DN 100 CF-F Rugged, powerful turbopump with a pumping speed of up to 260 l/s for N 2 Integrated TC 110 drive electronics Ideal for UHV applications

More information

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation S95.U0 / S95.U Head mounted temperature transmitters, programmable, Pt 00 (RTD), thermocouples, electrical isolation Resistance thermometer (,, wire circuit) Thermocouples Resistance remote signalling

More information

fischer connectors General Catalogue Edition 5.2

fischer connectors General Catalogue Edition 5.2 fischer connectors Edition. General Catalogue SUMMARY Ordering Information Mechanical Specifications Electrical Specifications Thermocouple Connectors Part number system and definitions, Body styles Coaxial,

More information

PERFORMANCE SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET INCH-POUND MIL-PRF-22885/90C 17 MARCH 1999 SUPERSEDING MIL-S-22885/90B 23 June 1989 PERFORMANCE SPECIFICATION SHEET SWITCH, PUSHBUTTON, ILLUMINATED, 4-LAMP 0.750 SQUARE, LOW LEVEL TO 7 AMPERES, (DRIPPROOF,

More information

SAND Unlimited Release Printed April 2004

SAND Unlimited Release Printed April 2004 SAND2004-1023 Unlimited Release Printed April 2004 Uncertainty Analysis of Thermocouple Measurements Used in Normal and Abnormal Thermal Environment Experiments at Sandia s Radiant Heat Facility and Lurance

More information

8D Series Common Section

8D Series Common Section MIL-DTL-38999 qualified crimp contacts - 1.27µm gold plated #22D type Part number Ø M39029/58 360 M39029/56 348 Conductor section AWG Conductor section mm² External Ø over insulator Min Max Min Max Min

More information

TFT Proto 5 TFT. 262K colors

TFT Proto 5 TFT. 262K colors TFT Proto TFT K colors Introduction to TFT Proto Figure : TFT Proto board TFT Proto enables you to easily add a touchscreen display to your design, whether it s a prototype or a final product. It carries

More information

15. Compare the result with the value you have taken above Compare the calculated pressure value with the actual pressure value that you have

15. Compare the result with the value you have taken above Compare the calculated pressure value with the actual pressure value that you have 105) to convert it to. 15. Compare the result with the value you have taken above. 17. 16. Compare the calculated pressure value with the actual pressure value that you have taken from the, is it the same?

More information

User Manual VX4750 Function Generator Module

User Manual VX4750 Function Generator Module User Manual VX4750 Function Generator Module 070-9151-05 This document applies for firmware version 2.60 and above. Copyright Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S.

More information

PCAN-MicroMod Evaluation Kit. Test and Development Environment for the PCAN-MicroMod. User Manual

PCAN-MicroMod Evaluation Kit. Test and Development Environment for the PCAN-MicroMod. User Manual Test and Development Environment for the PCAN-MicroMod Products taken into account Product Name Item Number Model PCAN-MicroMod Evaluation Kit (incl. PCAN-Dongle) PCAN-MicroMod Evaluation Kit (incl. PCAN-USB)

More information

AKD SYSTEM CONFIGURATION WITH KOLLMORGEN DDL LINEAR MOTORS By Kenny Hampton 1/12/2017 Rev. L

AKD SYSTEM CONFIGURATION WITH KOLLMORGEN DDL LINEAR MOTORS By Kenny Hampton 1/12/2017 Rev. L AKD SYSTEM CONFIGURATION WITH KOLLMORGEN DDL LINEAR MOTORS By Kenny Hampton 1/12/2017 Rev. L This document shows the wiring requirements for connecting the DDL linear motors to the AKD servo drive. It

More information

Section 7. Temperature Measurement

Section 7. Temperature Measurement Section 7 Temperature Measurement 7/25/2017 Engineering Measurements 7 1 Working Definition Temperature is a measure of the average kinetic energy of the molecules that make of a substance. After time,

More information

MAU100 Series. 1W, Miniature SIP, Single & Dual Output DC/DC Converters MINMAX. Block Diagram. Key Features

MAU100 Series. 1W, Miniature SIP, Single & Dual Output DC/DC Converters MINMAX. Block Diagram. Key Features MAU Series W, Miniature SIP, Single & DC/DC s Key Features Efficiency up to 0 Isolation MTBF >,000,000 Hours Low Cost Input,, and Output 3.3,,9,,,{,{9,{ and { Temperature Performance -0 to UL 9V-0 Package

More information

Pressure Transmitter ED 701

Pressure Transmitter ED 701 Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation

More information

STEVAL-FCU001V1. Flight controller unit evaluation board for toy drones. Description. Features

STEVAL-FCU001V1. Flight controller unit evaluation board for toy drones. Description. Features STEVAL-FCU00V Flight controller unit evaluation board for toy drones Data brief STLNLLH - N-channel 0 V, A STripFET H Power MOSFET STC0-00 ma Standalone linear Li-Ion battery charger RoHS compliant Features

More information

DIGITAL THERMOMETERS

DIGITAL THERMOMETERS NAVAIR 17-2OST-183 TECHNICAL MANUAL 00 INSTRUMENT CALIBRATION PROCEDURE DIGITAL THERMOMETERS DISTRIBUTION STATEMENT C. DISTRIBUTION AUTHORIZED TO U.S. GOVERNMENT AGENCIES AND THEIR CONTRACTORS TO PROTECT

More information

Lecture 11 Temperature Sensing. ECE 5900/6900 Fundamentals of Sensor Design

Lecture 11 Temperature Sensing. ECE 5900/6900 Fundamentals of Sensor Design EE 4900: Fundamentals of Sensor Design Lecture 11 Temperature Sensing 1 Temperature Sensing Q: What are we measuring? A: Temperature 2 SI Units: Celcius ( C), Kelvin (K) British Units: Fahrenheit ( F)

More information

CANBUS-THERMO-2CH Rev B v Channel CAN-Bus Thermocouple Interface K-Type. V1.0 July SK Pang Electronics Ltd

CANBUS-THERMO-2CH Rev B v Channel CAN-Bus Thermocouple Interface K-Type. V1.0 July SK Pang Electronics Ltd 2 Channel CAN-Bus Thermocouple Interface K-Type V1.0 July 2016 Product name Model number Manufacturer 2 Channel CAN-Bus Thermocouple Interface K-Type CANBUS-THERMO-2CH SK Pang Electronics Ltd 1 Contents

More information

technical bulletin Installation Instructions: Wall-Mount Dewpoint Probe ( )

technical bulletin Installation Instructions: Wall-Mount Dewpoint Probe ( ) Installation Instructions: Wall-Mount Dewpoint Probe (809-2011) The HMW90 Wall-Mount Dewpoint Probe (P/N 809-2011) HMW90 measures dewpoint for indoor applications such as anti-sweat heater control and

More information

MAU100 Series. 1W, Miniature SIP, Single & Dual Output DC/DC Converters MINMAX. Key Features

MAU100 Series. 1W, Miniature SIP, Single & Dual Output DC/DC Converters MINMAX. Key Features W, Miniature SIP, Single & Dual Output DC/DC s Key Features Efficiency up to % 000 Isolation MTBF >,000,000 Hours Low Cost Input,, and Output 3.3,,9,,,{,{9,{ and { Temperature Performance -0] to +] UL

More information

SINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol

SINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol SINEAX VK 66 for RTD and TC inputs, with HART procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application II () G SINEAX VK 66 is a two-wire head-mounted transmitter.

More information

TEMPERATURE COMPENSATION FOR MEAS PRESSURE SENSORS APPLICATION NOTE

TEMPERATURE COMPENSATION FOR MEAS PRESSURE SENSORS APPLICATION NOTE TEMPERATURE COMPENSATION FOR MEAS PRESSURE SENSORS INTRODUCTION Advancements in microelectronic technology have pushed silicon sensors not only toward greater sophistication and lower functional cost but

More information

ZF Series Force Transducers

ZF Series Force Transducers Data Sheet Series Force Transducers FEATURES 1 kn to 00 kn High accuracy For tensile or pressure forces Made of stainless steel Enclosure protection IP 67 DESCRIPTION The force transducers of the series

More information

MAU200 Series. 1W, High Isolation SIP, Single & Dual Output DC/DC Converters MINMAX. Block Diagram. Key Features

MAU200 Series. 1W, High Isolation SIP, Single & Dual Output DC/DC Converters MINMAX. Block Diagram. Key Features Component Distributors, Inc. ~ www.cdiweb.com ~ sales@cdiweb.com ~ -0--33 W, High Isolation SIP, Single & DC/DC s Key Features Efficiency up to 00 Isolation MTBF >,000,000 Hours Low Cost Input, and Output

More information

PARTS LIST GAS BOILERS MODELS: CG320 (E) CG325 (E) CG330 (E)

PARTS LIST GAS BOILERS MODELS: CG320 (E) CG325 (E) CG330 (E) PARTS LIST GAS BOILERS MODELS: CG320 (E) CG325 (E) CG330 (E) CROWN FOOD SERVICE EQUIPMENT LTD. 70 OAKDALE ROAD, DOWNSVIEW, (TORONTO), ONTARIO, CANADA, M3N 1V9 TELEPHONE: (416) 746-2358, FAX: (416) 746-8324

More information

MECHANICAL SPECIFICATIONS Specifications Dimensional Outline (typ.) 136.8(W) x 85.9 (H) x 2.95/4.6 (D) mm *)

MECHANICAL SPECIFICATIONS Specifications Dimensional Outline (typ.) 136.8(W) x 85.9 (H) x 2.95/4.6 (D) mm *) Toshiba Matsushita Display Technology Co., Ltd. PRODUCT INFORMATION FEATURES (1) 5.6 WIDE-SVGA(1024x600 pixels) display size for mini-notebook PC or UMPC (2) LED Backlight (2 parallel connection) (3) Glare

More information

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC HYGRASGARD AFF - LC AFTF - LC sensors, calibrateable, with and active passive output Quality product for HVAC sector, accuracy % r.h. The calibrateable room humidity and temperature sensor HYGRASGARD KFF

More information

Electrical and Magnetic Properties of High Temperature Superconductors Using Varying forms of Data Acquisition

Electrical and Magnetic Properties of High Temperature Superconductors Using Varying forms of Data Acquisition Journal of the Advanced Undergraduate Physics Laboratory Investigation Volume 1 Issue 1 Article 3 2013 Electrical and Magnetic Properties of High Temperature Superconductors Using Varying forms of Data

More information

PHYS 352 Assignment #1 Solutions

PHYS 352 Assignment #1 Solutions PHYS 352 Assignment #1 Solutions 1. Steinhart-Hart Equation for a thermistor In[1]:= a : 0.00128 In[2]:= b : 0.000236 In[3]:= In[4]:= d : 9.27 10^ 8 t r_ : a b Log r d Log r ^3 ^ 1 Note: Mathematica Log

More information

Veerapong Kanchanawongkul*

Veerapong Kanchanawongkul* Using LabVIEW to Development of Temperature Measurement System with Thermocouple and Thermistor AIS 08 Veerapong Kanchanawongkul* Department of Mechanical Engineering, Faculty of Engineering, South-East

More information

Instruction Manual. DTP Series DC Termination Panels

Instruction Manual. DTP Series DC Termination Panels Instruction Manual DTP Series DC Termination Panels Rev. B /00 DTP Series manual.p CPI Communications, Inc. Hensley Lane Wylie, TX 00 Phone () 0 WATS (00) FAX () 0 or () General Information The CPI Communications

More information

Chapter 7 Combinational Logic Networks

Chapter 7 Combinational Logic Networks Overview Design Example Design Example 2 Universal Gates NND-NND Networks NND Chips Chapter 7 Combinational Logic Networks SKEE223 Digital Electronics Mun im/rif/izam KE, Universiti Teknologi Malaysia

More information

CALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05

CALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05 Modulating digital controller for heating and cooling series REGI ERED SI EN ISO 00:000 Cert. n FM UNI EN ISO 00:000 Cert. n 000 0/0 G replaces dp 0/0 Function The controller can be used with three-point

More information

user's manual nx frequency converters resolver option board opt-bc

user's manual nx frequency converters resolver option board opt-bc user's manual nx frequency converters resolver option board opt-bc INDEX Document code: ud01039d Date: 18.2.2011 1. Resolver option board OPT-BC... 3 1.1 Resolver basics... 3 1.2 Resolver board features...

More information

J101 FBGND. 100u/16V C N C P VSSP C P FBGND 100N C u/63V C144 VDDP 100N C111 FBGND 100UF/35V R122 30K C192 FBGND VSSA 100N

J101 FBGND. 100u/16V C N C P VSSP C P FBGND 100N C u/63V C144 VDDP 100N C111 FBGND 100UF/35V R122 30K C192 FBGND VSSA 100N R K R K R K R K C 0N C 0N C 0N C 0N C 0P C 0P C N C N C N C 00N C0 00N C0 00N C 00N C 00N C 0P C 00N C 00N C 00N C N C 0P C 0P C 0N C 00N C 0N C 00N C 0P C 0P C 00N C 00N R0 0R R0 0R R R R R C u/v R 0K

More information

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011 SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with

More information

PHOENIX CONTACT - 04/2016. Features

PHOENIX CONTACT - 04/2016. Features Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.

More information

SC125MS. Data Sheet and Instruction Manual. ! Warning! Salem Controls Inc. Stepper Motor Driver. Last Updated 12/14/2004

SC125MS. Data Sheet and Instruction Manual. ! Warning! Salem Controls Inc. Stepper Motor Driver.   Last Updated 12/14/2004 SC125MS Stepper Motor Driver Salem Controls Inc. Last Updated 12/14/2004! Warning! Stepper motors and drivers use high current and voltages capable of causing severe injury. Do not operate this product

More information

University of Connecticut Department of Electrical and Computer Engineering. ECE 4901: Fall 2017 Spring 2018

University of Connecticut Department of Electrical and Computer Engineering. ECE 4901: Fall 2017 Spring 2018 University of Connecticut Department of Electrical and Computer Engineering ECE 4901: Fall 2017 Spring 2018 Team 1817 (Hubbell): Electrical plug, connector, and receptacle temperature sensor Jim Lin (EE)

More information

IRTS-P PRECISION INFRARED TEMPERATURE SENSOR INSTRUCTION MANUAL

IRTS-P PRECISION INFRARED TEMPERATURE SENSOR INSTRUCTION MANUAL IRTS-P PRECISION INFRARED TEMPERATURE SENSOR INSTRUCTION MANUAL 4/02 COPYRIGHT (c) 2002 CAMPBELL SCIENTIFIC, INC., APOGEE INSTRUMENTS, INC. This is a blank page. Warranty and Assistance The IRTS-P PRECISION

More information

MAX Cold-Junction Compensated Thermocouple-to-Digital Converter ABSOLUTE MAXIMUM RATINGS. PACKAGE THERMAL CHARACTERISTICS (Note 1)

MAX Cold-Junction Compensated Thermocouple-to-Digital Converter ABSOLUTE MAXIMUM RATINGS. PACKAGE THERMAL CHARACTERISTICS (Note 1) AVAILABLE General Description The performs cold-junction compensation and digitizes the signal from a K-, J-, N-, T-, S-, R-, or E-type thermocouple. The data is output in a signed 14-bit, SPI-compatible,

More information

Temperature Compensation for MEAS Pressure Sensors

Temperature Compensation for MEAS Pressure Sensors INTRODUCTION Advancements in microelectronic technology have pushed silicon sensors not only toward greater sophistication and lower functional cost but also in the direction of higher performance. The

More information

HFM 100 Series. Thermal Conductivity Meter for measurement of insulation and construction materials.

HFM 100 Series. Thermal Conductivity Meter for measurement of insulation and construction materials. HFM 100 Series Conforms to International Standards ASTM C518, ISO 8301, and EN 12667 Thermal Conductivity Meter for measurement of insulation and construction materials. Hot Disk TPS -160 to 1000 C HFM

More information

PTC04-DB Daughter Board for Melexis PTC devices. Features and Benefits. Applications. Ordering Information. Accesoires. Functional Diagram

PTC04-DB Daughter Board for Melexis PTC devices. Features and Benefits. Applications. Ordering Information. Accesoires. Functional Diagram PTC0-DB-0 Features and Benefits PTC0 interface board for testing devices 0 0 0 00 Applications Experimental tool for Lab and Prototyping Production Equipment for Serial Programming Ordering Information

More information

Sensors Conditioning Module

Sensors Conditioning Module Sensors Conditioning Module Version 1.00 Microstar Laboratories, Inc. This manual is protected by copyright. All rights are reserved. No part of this manual may be photocopied, reproduced, or translated

More information

Overview. Multiplexor. cs281: Introduction to Computer Systems Lab02 Basic Combinational Circuits: The Mux and the Adder

Overview. Multiplexor. cs281: Introduction to Computer Systems Lab02 Basic Combinational Circuits: The Mux and the Adder cs281: Introduction to Computer Systems Lab02 Basic Combinational Circuits: The Mux and the Adder Overview The objective of this lab is to understand two basic combinational circuits the multiplexor and

More information

POINTS OF CAUTION BEFORE USE...

POINTS OF CAUTION BEFORE USE... INSTRUCTION MANUAL NPN DISCRETE INPUT & NPN TRANSISTOR OUTPUT MODULE, 6 points each (-I/-II, e-con connector) MODEL BEFORE USE... Thank you for choosing M-System. Before use, check the contents of the

More information

Exchangeable measuring insets SensyTemp TSA101

Exchangeable measuring insets SensyTemp TSA101 Contents Data Sheet Exchangeable measuring insets SensyTemp TSA101 for resistance thermometers and thermocouples Structure of electrical thermometers - Exchangeability during operation based on modular

More information

Measurements & Instrumentation. Module 3: Temperature Sensors

Measurements & Instrumentation. Module 3: Temperature Sensors Measurements & Instrumentation PREPARED BY Academic Services Unit August 2013 Institute of Applied Technology, 2013 Module Objectives Upon successful completion of this module, students should be able

More information

SI 6 Schematic. Contents. Revision Histroy. Related Documents. Description Sheet 1. Sheets No W/S Ver 0.1 Sheet 2.

SI 6 Schematic. Contents. Revision Histroy. Related Documents. Description Sheet 1. Sheets No W/S Ver 0.1 Sheet 2. Schematic Contents ision Histroy Sheets No Description Version Date Description Sheet Contents 0. 0.0.0 W/S Ver 0. Sheet CP80 SENSOR Sheet NVS700 ISP Sheet FPD-Link III Serializer Sheet POWER Related Documents

More information

PI2EQX6804-ANJE EvalBoard Rev.A User Guide

PI2EQX6804-ANJE EvalBoard Rev.A User Guide PIEQX0-ANJE EvalBoard Rev.A User Guide Introduction Pericom Semiconductor s PIEQX0-A is a low power, SAS, SATA, XAUI signal Re-Driver. The device provides programmable equalization, amplification, and

More information

MAX31855 Cold-Junction Compensated Thermocouple-to-Digital Converter

MAX31855 Cold-Junction Compensated Thermocouple-to-Digital Converter 19-5793; Rev 0; 3/11 General Description The performs cold-junction compensation and digitizes the signal from a K, J, N, T, or E type thermocouple. (Contact the factory for S and R type thermocouples.)

More information

PTC04-DB Daughter Board for Melexis PTC devices

PTC04-DB Daughter Board for Melexis PTC devices PTC0-DB-0 Features and Benefits PTC0 interface board for testing devices: MLX0 MLX0 MLX0 MLX0 MLX00 MLX0 MLX0 MLX0 Applications Experimental tool for Lab and Prototyping Production Equipment for Serial

More information

Acceleration/Velocity/Displacement VIBRATION METER

Acceleration/Velocity/Displacement VIBRATION METER Acceleration/Velocity/Displacement VIBRATION METER Model : VB-8220 Your purchase of this VIBRATION METER marks a step forward for you into the field of precision measurement. Although this METER is a complex

More information

HARTING D-Sub Selection Guide

HARTING D-Sub Selection Guide HARTING D-Sub Selection Guide People Power Partnership D-Sub Selection Guide D-Sub Device Connectivity HARTING Connectivity & Networks generates solutions throughout the triad of Installation Technology,

More information

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components: SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine

More information

ATS177. General Description. Features. Applications. Ordering Information SINGLE OUTPUT HALL EFFECT LATCH ATS177 - P L - X - X

ATS177. General Description. Features. Applications. Ordering Information SINGLE OUTPUT HALL EFFECT LATCH ATS177 - P L - X - X Features General Description 3.5V to 20V DC operation voltage Temperature compensation Wide operating voltage range Open-Collector pre-driver 25mA maximum sinking output current Reverse polarity protection

More information

89BSD CALCULATION METHOD APPLICATION NOTE

89BSD CALCULATION METHOD APPLICATION NOTE FUNCTIONAL DESCRIPTION GENERAL The 89BSD consists of a piezoresistive sensor and a sensor interface IC. The main function of the sensor interface IC is to convert the uncompensated analogue output voltage

More information

I m. R s. Digital. R x. OhmmetersxSeries Shunt Digital. R m

I m. R s. Digital. R x. OhmmetersxSeries Shunt Digital. R m µa Meter I I s I m s E Digital x I Voltmeter x x E µa Meter m Is OhmmetersxSeries Shunt Digital EIx= = ()E sm x mxvi= x Shunt Ohmmeter Shunt s x E µa Meter I m I m V m E ) ( v I E ) ( E v E v E I When

More information

GR16. Technical Manual. 10 M SPS, 16-bit Analog Signal Digitizer up to 8MB FIFO

GR16. Technical Manual. 10 M SPS, 16-bit Analog Signal Digitizer up to 8MB FIFO GR M SPS, -bit Analog Signal Digitizer up to MB FIFO Technical Manual 90 th Street, Davis, CA 9, USA Tel: 0--00 Fax: 0--0 Email: sales@tern.com web site: www.tern.com COPYRIGHT GR, EL, Grabber, and A-Engine

More information

Installation guide 862 MIT / MIR

Installation guide 862 MIT / MIR Installation guide 862 MIT / MIR in combination with: 864 MTT or 863 MRT or (dual) spot element November 2005 Part no. 4416.232_Rev3 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100

More information

Thermocouple Calibrations and Heat Transfer Coefficients

Thermocouple Calibrations and Heat Transfer Coefficients Laboratory Experiment 5: Thermocouple Calibrations and Heat Transfer Coefficients Presented to the University of California, San Diego Department of Mechanical and Aerospace Engineering MAE 170 Prepared

More information

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202 Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202 Your purchase of this VIBRATION METER marks a step forward for you into the field of precision measurement. Although this METER is

More information

Amphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme

Amphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme Amphenol Amphenol-Tuchel Electronics GmbH Series C 146 Heavy Duty Connectors Core Programme The Company General information These connectors are designed and produced in conformity with the voltage directive

More information

LM102A. Middle Power LED Series Flip Chip Package. LM102A opens up a new world of lighting design with its high output and small form factors

LM102A. Middle Power LED Series Flip Chip Package. LM102A opens up a new world of lighting design with its high output and small form factors Product Family Data Sheet Rev. 1.0 2016..3.31. 1# Middle Power LED Series Flip Chip Package LM102A LM102A opens up a new world of lighting design with its high output and small form factors Features &