E2T0 DVP
|
|
- Luke McCoy
- 6 years ago
- Views:
Transcription
1 E2T DVP
2 ENGLISH Thank you for choosing Delta s DVP series PLC. DVP4TC-E2 temperature measurement module receives 4 points of external thermocouple temperature sensors (J-type, K-type, R-type, S-type, T-type, E-type, N-type, 8mV) and convert them into 16-bit digital signals. Users can select temperatures in Celsius (resolution:.1 C) or Fahrenheit (resolution:.1 F). In addition, you can access the data in the module by applying FROM/TO instructions or read the average value of channels directly by using MOV instruction (Please refer to allocation of special registers D99 ~ D9999). This instruction sheet provides only information on the electrical specification, general functions, installation and wiring. For detailed program design and applicable instructions, please refer to DVP-ES2 Operation Manual: Modules. For details of the optional peripheral, please refer to the instruction sheet enclosed in it. This is an OPEN TYPE I/O module and therefore should be installed in an enclosure free of airborne dust, humidity, electric shock and vibration. The enclosure should prevent non-maintenance staff from operating the device (e.g. key or specific tools are required for operating the enclosure) in case danger and damage on the device may occur. DO NOT connect the input AC power supply to any of the I/O terminals; otherwise serious damage may occur. Check all the wiring again before switching on the power. Make sure the ground terminal is correctly grounded in order to prevent electromagnetic interference. Product Profile & Dimension Removable I/O terminal Model Name Power / A->D / Error indicators I/O module connection port 4TC-E2 4AI-TC Mounting slot (35mm) I/O module clip I/O module connection port I/O terminal No. Direct mounting hole [ Figure 1 ] [ Figure 2 ] Unit: mm - 1 -
3 External Wiring Thermocouple + Voltage input -8mV~8mV Terminal of power module - Grounding (1 Shielded cable *1 Shielded cable *1 *2 System grounding or less) CH1 CH4-2 - I1+ I1 - I4+ I4-24V V Cold-Junction Compensation DC/ DC Converter Note 1: Wiring for analog input should adopt the connection cable or shielding cable of thermocouple temperature sensor J-type, K-type, R-type, S-type, T-type, E-type and N-type and should be separated from other power cable or wirings that may cause interference. Note 2: Connect the terminal on both power module and DVP4TC-E2 to the system grounding point then ground the point or connect it to the cover of power distribution cabinet. I/O Terminal Layout I1+ I1- I2+ I2- I3+ I3- I4+ I4- DVP4TC-E2 (4AI) 24V V Electrical Specifications DVP4TC-E2 Power supply voltage 24VDC (2.4VDC ~ 28.8VDC) (-15% ~ +2%) Max. rated power consumption Connector Operation/storage Vibration/shock immunity Series connection to DVP-PLC MPU 1.2W, supplied by external power source MUX 5V AG European standard removable terminal block (Pin pitch: 5mm) Operation: C~55 C (temp.), 5~95% (humidity), Pollution degree2 Storage: -25 C~7 C (temp.), 5~95% (humidity) International standards: IEC , IEC (TEST Fc)/ IEC & IEC (TEST Ea) The modules are numbered from to 7 automatically by their distance from MPU. No. is the closest to MPU and No.7 is the furthest. Maximum 8 modules are allowed to connect to MPU and will not occupy any digital I/O points. Functions Specifications DVP4TC-E2 Celsius ( C) Fahrenheit ( F) Analog input channel 4 channels Digital data format Response time Overall accuracy Applicable sensor type 2 s complement of 16 bits 2ms / each channel Voltage input ±.3% when in full scale (25 C, 77 F) ±.6% when in full scale within the range of ~ 55 C, 32 ~ 131 F J-type, K-type, R-type, S-type, T-type, E-type, N-type thermocouple; ±8mV voltage input
4 DVP4TC-E2 Celsius ( C) Fahrenheit ( F) Range of input Range of digital conversion J-type: -1 C ~1,15 C K-type: -1 C ~ 1,35 C R-type: C ~ 1,75 C S-type: C ~ 1,75 C T-type: -15 C ~ 39 C E-type: -15 C ~ 98 C N-type: -15 C ~ 1,28 C J-type: K-1, ~ K11,5 K- type: K-1, ~ K13,5 R-type: K- ~ K17,5 S-type: K ~ K17,5 T-type: K-1,5 ~ K3,9 E-type: K-1,5 ~ K9,8 N-type: K-1,5 ~ K12,8 J-type: -148 F ~ 2,12 F K-type: -148 F ~ 2,462 F R-type: 32 F ~ 3,182 F S-type: 32 F ~ 3,182 F T-type: -238 F ~734 F E-type: -238 F ~ 1,796 F N-type: -238 F ~2,336 F J-type: K-1,48 ~ K21,2 K-type: K-1,48 ~ K24,62 R-type: K32 ~ K31,82 S-type: K32 ~ K31,82 T-type: K-2,38 ~ K7,34 E-type: K-2,38 ~ K17,96 N-type: K-2,38 ~ K23,36 Resolution 16 bits (.1 C) 16bits (.1 F) Average function Voltage input ±8mV ±8, 16 bits (.1mV) Supported. Available for setting up sampling range in CR#8 ~ CR#11. Range: K1 ~ K1. Self-diagnosis Isolation Upper and lower bound detection in all channels Optical coupler isolation between digital circuits and analog circuits. Isolation between analog channels. 5VDC between digital circuits and Ground 5VDC between analog circuits and Ground 5VDC between analog circuits and digital circuits 5VDC between 24VDC and Ground 12VAC between analog channels Control Register CR# Attrib. Register content Description # O R Model name Set up by the system: DVP4TC-E2 model code = H 83 #1 O R Firmware version Display the current firmware version in hex. #2 O R/W CH1 Input mode setting #3 O R/W CH2 Input mode setting #4 O R/W CH3 Input mode setting #5 O R/W CH4 Input mode setting #7 O R/W Temperature unit setting #8 O R/W CH1 sampling range #9 O R/W CH2 sampling range #1 O R/W CH3 sampling range #11 O R/W CH4 sampling range #12 X R #13 X R Average temperature measured at CH1 Average temperature measured at CH2-3 - Input mode: Default = H. Take CH1 for example: Mode (H ): J-type (-1 C ~1,15 C) Mode 1 (H 1): K-type (-1 C ~ 1,35 C) Mode 2 (H 2): R-type ( C ~ 1,75 C) Mode 3 (H 3): S-type ( C ~ 1,75 C) Mode 4 (H 4): T-type (-15 C ~ 39 C) Mode 5 (H 5): E-type (-15 C ~ 98 C) Mode 6 (H 6): N-type (-15 C ~ 1,28 C) Mode 7 (H 7): -8mV~+8mV Mode -1(H FFFF): Close Select the temperature unit (Celsius C / Fahrenheit F). Default = H( C) Set sampling range at CH1 ~ CH4 Range = K1 ~ K1 Default = K1 Average temperature measured at CH1 ~ Ch2 Temperature unit: set in CR#7
5 CR# Attrib. Register content Description #14 X R #15 X R #2 X R #21 X R #22 X R #23 X R Average temperature measured at CH3 Average temperature measured at CH4 Present temperature measured at CH1 Present temperature measured at CH2 Present temperature measured at CH3 Present temperature measured at CH4 #28 O R/W Adjusted Offset value of CH1 #29 O R/W Adjusted Offset value of CH2 #3 O R/W Adjusted Offset value of CH3 #31 O R/W Adjusted Offset value of CH4 Average temperature measured at CH3 ~ Ch4 Temperature unit: set in CR#7 Present temperature measured at CH1 ~ CH4 Temperature unit: set in CR#7 Set the adjusted Offset value of Ch1 ~ Ch4. Default = K Range: K-4 ~ K4 Temperature unit: set in CR#7 Definition of Offset at Ch1 ~ Ch4 in DVP4TC-E2: Deviation digital value from the target value. #4 O R/W #41 X R/W #42 X R/W #43 X R Error status #1 O R/W Function: Set value changing prohibited Function: Save all the set values Function: Return to default setting Function: Enable / Disable limit detection #11 X R/W Upper and lower bound status #12 O R/W Set value of CH1 upper bound #13 O R/W Set value of CH2 upper bound #14 O R/W Set value of CH3 upper bound #15 O R/W Set value of CH4 upper bound #18 O R/W Set value of CH1 lower bound #19 O R/W Set value of CH2 lower bound #11 O R/W Set value of CH3 lower bound #111 O R/W Set value of CH4 lower bound CR#43: Error status value. See the table below: Prohibit set value changing in CH1 ~ CH4 Save all the set values, Default =H Set all values to default setting, Default = H Register for storing all error status. See the table of error status for more information. Enable / Disable the upper and lower bound detection function. Default= H. Display the upper and lower bound value, Default =H Set value of CH1~CH4 upper bound. Default = K32. Set value of CH1~CH4 lower bound. Default = K-32. Description bit K1 (H 1) Power supply error bit6 K64 (H 4) CH4 Conversion error bit1 K2 (H 2) Hardware error bit9 K512(H 2) Mode setting error bit2 K4 (H 4) Upper / lower bound error bit1 K124(H 4) bit3 K8 (H 8) CH1 Conversion error bit11 K248(H 8) bit4 K16 (H 1) CH2 Conversion error bit12 K496(H 1) bit5 K32 (H 2) CH3 Conversion error bit13 K8192(H 2) Sampling range error Upper / lower bound setting error Set value changing prohibited Communication breakdown on next module - 4 -
6 Description Note: Each error status is determined by the corresponding bit (b ~ b13) and there may be more than 2 errors occurring at the same time. = normal; 1 = error PID Control Registers CR# CH1 CH2 CH3 CH4 #12 #14 #16 #18 O R/W Save Register content Description Set temperature value Please set the temperature value according to proper range of each sensor type. Default = K #121 #141 #161 #181 O R/W Sampling time (s) Range: K1 ~ K3 (s). Default = K2 #122 #142 #162 #182 O R/W K P Proportional control constant. Default = K121 #123 #143 #163 #183 O R/W K I Integral constant. Default = K2,98 #124 #144 #164 #184 O R/W K D Derivative constant. Default = K-29 #125 #145 #165 #185 O R/W Upper limit of I value Upper limit of I value. Default = K #126 #146 #166 #186 O R/W Lower limit of I value Lower limit of I value. Default = K #127 #147 #167 #187 X R I value Current accumulated offset value #128 #148 #168 #188 O R/W Heating/cooling : Heater, 1: Cooler. Default = K #129 #149 #169 #189 O R/W Upper limit of output Upper limit of output. Default = K32, #13 #15 #17 #19 O R/W Lower limit of output Lower limit of output. Default = K #131 #151 #171 #191 X R Output percentage Output percentage (Unit:.1%) #132 #152 #172 #192 X R Output width (ms) Width of control output. Unit: ms #133 #153 #173 #193 X R Output cycle (ms) Cycle of control output. Unit: ms #134 #154 #174 #194 X R Output volume Output volume #135 #155 #175 #195 X R/W PID_RUN/STOP : STOP, 1: RUN. Default = K #136 #156 #176 #196 X R/W Auto-tuning : Disabled, 1: Auto-tuning. Default = K Symbols: O: When CR#41 is set to H 5678, the set value of CR will be saved. X: set value will not be saved. R: able to read data by using FROM instruction. W: able to write data by using TO instruction. Explanation on Special Registers D99~D9999 When DVP-ES2 MPU is connected with modules, registers D99~D9999 will be reserved for storing values from modules. You can apply MOV instruction to operate values in D99~D9999. When DVP-ES2 MPU is connected with DVP4TC-E2, the configuration of special registers is as below: Module # Module #1 Module #2 Module #3 Module #4 Module #5 Module #6 Module #7 Description D132 D1321 D1322 D1323 D1324 D1325 D1326 D1327 Model Code D99 D991 D992 D993 D994 D995 D996 D997 D991 D9911 D9921 D9931 D9941 D9951 D9961 D9971 D992 D9912 D9922 D9932 D9942 D9952 D9962 D9972 D993 D9913 D9923 D9933 D9943 D9953 D9963 D9973 CH1 average temperature CH2 average temperature CH3 average temperature CH4 average temperature - 5 -
7 Note 1: D99 ~ D9999 are average input values of CH1 ~ CH4 and the sampling range is K1 ~ K1. When the sampling range is set to K1, the values displayed in D99~D9999 are current values. You can use: 1. ES_AIO Configuration Function of WPLSoft or 2. FROM/TO instructions (CR#8 ~ CR#11) to set the sampling range as K1. Adjust TC Conversion Curve Users can adjust the conversion curves according to the actual needs by changing the Offset value (CR#28 ~ CR#31). Offset in DVP4TC-E2: Deviation digital value from the target value. Equation for temperature measured Mode ~ Mode6:.1 X ( ) Y Offset. 1( ) Y=Digital output, X=Measured input Equation for voltage input Mode7:.1mV = 8mV/8 X (mv ) Y Offset. 1(m V ) Mode : J-type thermocouple Digital output +11,5 (+21,2) Y=Digital output, X=Voltage input Mode 1: K-type thermocouple +13,5 (+24,62) Digital output -1 C (-148 F) Measured temperature input -1 C (-148 F) Measured temperature input +1,15 C (+2,12 F) -1,(-1,48) +1,35 C (+2,462 F) -1,(-1,48) Mode 2: R-type thermocouple Mode 3: S-type thermocouple Digital output +17,5 (+31,82) Mode 4: T-type thermocouple Digital output +3,9 (+7,34) C (-32 F) Measured temperature input -15 C (-238 F) Measured temperature input (-32) +1,75 C (+3,182 F) +39 C (+734 F) -1,5(-2,38) Mode 5: E-type thermocouple Digital output +9,8 (+17,96) Mode 6: N-type thermocouple Digital output +12,8 (+23,36) -15 C (-238 F) Measured temperature input -15 C (-238 F) Measured input impedance +98 C (+1,796 F) -1,5(-2,38) +1,28 C (+2,336 F) -1,5(-2,38) - 6 -
8 Mode of CR#2~ CR#5-1 C ~ 115 C (-1~115) -148 F ~ 212 F (-148~212) Mode 1 of CR#2~ CR#5-1 C ~ 135 C (-1~135) -148 F ~ 2462 F (-148~2462) Mode 2, 3 of CR#2~ CR#5 C ~ 175 C (~175) 32 F ~ 3182 F (32~3182) Mode 4 of CR#2~ CR#5-15 C ~ 39 C (-15~39) -238 F ~ 734 F (-238~734) Mode 5 of CR#2~ CR#5-15 C ~ 98 C (-15~98) -238 F ~ 1796 F (-238~1796) Mode 6 of CR#2~ CR#5-15 C ~ 128 C (-15~128) -238 F ~ 2336 F (-238~2336) Offset (CR#34 ~ CR#37) Deviation digital value corresponds to C/ F Mode 7: +8, Digital output -8mV +8mV Voltage input -8, Mode 7 of CR#2~ CR#5-8mV ~ +8mV (-8~8) Offset (CR#34 ~ CR#37) Deviation digital value corresponds to mv - 7 -
9 DVP DVP4TC-E2 4 (J, K, R, S, T, E, N ) ±8mV 16 ( C) ( F).1 C.1 F FROM / TO MOV ( D99 ~ D9999 ) DVP-ES2 (OPEN TYPE) A->D I/O 4TC-E2 4A I-T C DIN (35mm) I/O I/O 1Figure2mm *1 CH1 I1+ I1- MUX -8mV~8mV *1 CH4 I4+ I4- *2 V 24V DC/ DC 5V AG ( 1 ) 1JKRSTEN - 8 -
10 2 DVP4TC-E2 2 DVP4TC E2 24VDC (2.4VDC ~ 28.8VDC) (-15% ~ +2%) DVP-PLC 1.2W (5mm) C ~ 55 C5 ~ 95% 2-25 C ~ 7 C 5 ~ 95% IEC IEC (TEST Fc) / IEC & IEC (TEST Ea) 78 I/O DVP4TC-E2 ( C) ( F) ms /.3% (25 C, 77 F).6% ( ~ 55 C, 32 ~ 131 F) J-type, K-type, R-type, S-type, T-type, E-type, N-type ; ±8mV J-type: -1 C ~1,15 C K-type: -1 C ~ 1,35 C R-type: C ~ 1,75 C S-type: C ~ 1,75 C T-type: -15 C ~ 39 C E-type: -15 C ~ 98 C N-type: -15 C ~ 1,28 C J-type: K-1, ~ K11,5 K- type: K-1, ~ K13,5 R-type: K- ~ K17,5 S-type: K ~ K17,5 T-type: K-1,5 ~ K3,9 E-type: K-1,5 ~ K9,8 N-type: K-1,5 ~ K12,8 J-type: -148 F ~ 2,12 F K-type: -148 F ~ 2,462 F R-type: 32 F ~ 3,182 F S-type: 32 F ~ 3,182 F T-type: -238 F ~734 F E-type: -238 F ~ 1,796 F N-type: -238 F ~2,336 F J-type: K-1,48 ~ K21,2 K-type: K-1,48 ~ K24,62 R-type: K32 ~ K31,82 S-type: K32 ~ K31,82 T-type: K-2,38 ~ K7,34 E-type: K-2,38 ~ K17,96 N-type: K-2,38 ~ K23,36 16 bits (.1 C) 16 bits (.1 F) ±8mV ±8, 16 bits (.1mV) CR#8 ~ CR#11K1 ~ K1 / 5VDC - 9 -
11 DVP4TC-E2 ( C) ( F) 5VDC 5VDC 24VDC5VDC 12VAC CR CR# # O R DVP4TC-E2 = H 83 #1 O R 16 #2 O R/W CH1 #3 O R/W CH2 #4 O R/W CH3 #5 O R/W CH4 #7 O R/W #8 O R/W CH1 #9 O R/W CH2 #1 O R/W CH3 #11 O R/W CH4 : H CH1 (H ): J-type (-1 C ~ 115 C) 1 (H 1): K-type (-1 C ~ 135 C) 2 (H 2): R-type ( C ~ 1,75 C) 3 (H 3): S-type ( C ~ 1,75 C) 4 (H 4): T-type (-15 C ~ 39 C) 5 (H 5): E-type (-15 C ~ 98 C) 6 (H 6): N-type (-15 C ~ 1,28 C) 7 (H 7): -8mV ~ +8mV -1 (H FFFF): CH1 ( C / F) H( C) CH1 ~ CH4 K1 ~ K1 K1 #12 X R CH1 #13 X R CH2 #14 X R CH3 CH1 ~ CH4 CR#7 #15 X R CH4 #2 X R CH1 #21 X R CH2 #22 X R CH3 CH1 ~ CH4 CR#7 #23 X R CH4 #28 O R/W CH1Offset #29 O R/W CH2Offset #3 O R/W CH3Offset #31 O R/W CH4Offset CH1 ~ CH4 Offset K-4 ~ K4 K CR#7 Offset #4 O R/W CH1 ~ CH4 H #41 X R/W H #42 X R/W H #43 X R #1 O R/W / /H #11 X R/W H #12 O R/W CH1 #13 O R/W CH2 CH1 ~ CH2K32-1 -
12 CR# #14 O R/W CH3 #15 O R/W CH4 CH3 ~ CH4K32 #18 O R/W CH1 #19 O R/W CH2 #11 O R/W CH3 CH1 ~ CH4K-32 #111 O R/W CH4 CR#43 bit K1 (H 1) bit6 K64 (H 4) CH4 bit1 K2 (H 2) bit9 K512(H 2) bit2 K4 (H 4) bit1 K124(H 4) bit3 K8 (H 8) CH1 bit11 K248(H 8) bit4 K16 (H 1) CH2 bit12 K496(H 1) bit5 K32 (H 2) CH3 bit13 K8192(H 2) b ~ b13 1 PID CR# CH1 CH2 CH3 CH4 #12 #14 #16 #18 O R/W K #121 #141 #161 #181 O R/W (s) K1 ~ K3 (s)k2 #122 #142 #162 #182 O R/W K P K121 #123 #143 #163 #183 O R/W K I K2,98 #124 #144 #164 #184 O R/W K D K-29 #125 #145 #165 #185 O R/W K #126 #146 #166 #186 O R/W K #127 #147 #167 #187 X R #128 #148 #168 #188 O R/W H H 1 H #129 #149 #169 #189 O R/W #13 #15 #17 #19 O R/W K-32,76 ~ K32,76 K32, K-32,76 ~ K32,76 K #131 #151 #171 #191 X R K ~ K1,.1% #132 #152 #172 #192 X R (ms) ms #133 #153 #173 #193 X R (ms) ms #134 #154 #174 #194 X R #135 #155 #175 #195 X R/W PID_Run/Stop H StopH 1RunK #136 #156 #176 #196 X R/W Auto-tuning H H 1Auto-tuning K O CR#41H 5678X RFROMWTO
13 D99 ~ D9999 DVP-ES2I/OD99 ~ D9999MOV D99 ~ D9999 DVP-ES2DVP4TC-E D132 D1321 D1322 D1323 D1324 D1325 D1326 D1327 D99 D991 D992 D993 D994 D995 D996 D997 D991 D9911 D9921 D9931 D9941 D9951 D9961 D9971 D992 D9912 D9922 D9932 D9942 D9952 D9962 D9972 D993 D9913 D9923 D9933 D9943 D9953 D9963 D9973 I/O CH1 CH2 CH3 CH4 D99 ~ D9999 WPLSoftFROM/TO (CR#8 ~ CR#11) 1 TC Offset(CR#28~CR#31) Offset ~ mV = 8mV/8 6 J-type +11,5 (+21,2) 1K-type +13,5 (+24,62) -1 C (-148 F) +1,15 C (+2,12 F) -1,(-1,48) 2R-type 3S-type +17,5 (+31,82) -1 C (-148 F) +1,35 C (+2,462 F) -1,(-1,48) 4T-type +3,9 (+7,34) C (-32 F) (-32) +1,75 C (+3,182 F) -15 C (-238 F) +39 C (+734 F) -1,5(-2,38)
14 5E-type 6N-type +9,8 (+17,96) +12,8 (+23,36) -15 C (-238 F) +98 C (+1,796 F) -1,5(-2,38) -15 C (-238 F) +1,28 C (+2,336 F) -1,5(-2,38) of CR#2~ CR#5-1 C ~ 115 C (-1~115) -148 F ~ 212 F (-148~212) 1 of CR#2~ CR#5-1 C ~ 135 C (-1~135) -148 F ~ 2462 F (-148~2462) 2, 3 of CR#2~ CR#5 C ~ 175 C (~175) 32 F ~ 3182 F (32~3182) 4 of CR#2~ CR#5-15 C ~ 39 C (-15~39) -238 F ~ 734 F (-238~734) 5 of CR#2~ CR#5-15 C ~ 98 C (-15~98) -238 F ~ 1796 F (-238~1796) 6 of CR#2~ CR#5-15 C ~ 128 C (-15~128) -238 F ~ 2336 F (-238~2336) Offset (CR#34 ~ CR#37) 7-8mV +8, +8mV -8, 7 of CR#2~ CR#5-8mV~+8mV (-8~8) Offset (CR#34 ~ CR#37) mv
15 DVP DVP4TC-E2 4 (J, K, R, S, T, E, N ) ±8mV 16 ( C) ( F).1 C.1 F FROM / TO MOV ( D99 ~ D9999 ) DVP-ES2 (OPEN TYPE) / / A->D I/O 4TC-E2 4A I-TC DIN (35mm) I/O I/O 1Figure2mm *1 CH1 I1+ I1- MUX -8mV~8mV *1 CH4 I4+ I4- *2 V 24V DC/ DC 5V AG 1 1JKRSTEN
16 2 DVP4TC-E2 2 DVP4TC-E2 24VDC (2.4VDC ~ 28.8VDC) (-15% ~ +2%) DVP-PLC (5mm) 78 I/O C ~ 55 C5 ~ 95% 2-25 C ~ 7 C 5 ~ 95% IEC IEC (TEST Fc) / IEC & IEC (TEST Ea) 24VDC (2.4VDC ~ 28.8VDC) (-15% ~ +2%)1.2W DVP4TC-E2 ( C) ( F) ms /.3% (25 C, 77 F).6% ( ~ 55 C, 32 ~ 131 F) J-type, K-type, R-type, S-type, T-type, E-type, N-type ±8mV J-type: -1 C ~1,15 C K-type: -1 C ~ 1,35 C R-type: C ~ 1,75 C S-type: C ~ 1,75 C T-type: -15 C ~ 39 C E-type: -15 C ~ 98 C N-type: -15 C ~ 1,28 C J-type: K-1, ~ K11,5 K- type: K-1, ~ K13,5 R-type: K- ~ K17,5 S-type: K ~ K17,5 T-type: K-1,5 ~ K3,9 E-type: K-1,5 ~ K9,8 N-type: K-1,5 ~ K12, J-type: -148 F ~ 2,12 F K-type: -148 F ~ 2,462 F R-type: 32 F ~ 3,182 F S-type: 32 F ~ 3,182 F T-type: -238 F ~734 F E-type: -238 F ~ 1,796 F N-type: -238 F ~2,336 F J-type: K-1,48 ~ K21,2 K-type: K-1,48 ~ K24,62 R-type: K32 ~ K31,82 S-type: K32 ~ K31,82 T-type: K-2,38 ~ K7,34 E-type: K-2,38 ~ K17,96 N-type: K-2,38 ~ K23,36 16 bits (.1 C) 16 bits (.1 F) CR#8 ~ CR#11K1 ~ K1 / ±8mV ±8, 16 bits (.1mV) 5VDC
17 DVP4TC-E2 ( C) ( F) 5VDC 5VDC 24VDC5VDC 12VAC CR CR# # O R DVP4TC-E2 = H 83 #1 O R 16 #2 O R/W CH1 #3 O R/W CH2 #4 O R/W CH3 #5 O R/W CH4 #7 O R/W #8 O R/W CH1 #9 O R/W CH2 #1 O R/W CH3 #11 O R/W CH4 : H CH1 (H ): J-type (-1 C ~ 115 C) 1 (H 1): K-type (-1 C ~ 135 C) 2 (H 2): R-type ( C ~ 1,75 C) 3 (H 3): S-type ( C ~ 1,75 C) 4 (H 4): T-type (-15 C ~ 39 C) 5 (H 5): E-type (-15 C ~ 98 C) 6 (H 6): N-type (-15 C ~ 1,28 C) 7 (H 7): -8mV ~ +8mV -1 (H FFFF): CH1 ( C / F) H( C) CH1 ~ CH4 K1 ~ K1 K1 #12 X R CH1 #13 X R CH2 #14 X R CH3 CH1 ~ CH4 CR#7 #15 X R CH4 #2 X R CH1 #21 X R CH2 #22 X R CH3 CH1 ~ CH4 CR#7 #23 X R CH4 #28 O R/W CH1Offset #29 O R/W CH2Offset #3 O R/W CH3Offset #31 O R/W CH4Offset CH1 ~ CH4 Offset K-4 ~ K4 K CR#7 Offset #4 O R/W CH1 ~ CH4 H #41 X R/W H #42 X R/W H #43 X R #1 O R/W / /H #11 X R/W H #12 O R/W CH1 #13 O R/W CH2 CH1 ~ CH2 K
18 CR# #14 O R/W CH3 #15 O R/W CH4 CH3 ~ CH4 K32 #18 O R/W CH1 #19 O R/W CH2 #11 O R/W CH3 CH1 ~ CH4K-32 #111 O R/W CH4 CR#43 bit K1 (H 1) bit6 K64 (H 4) CH4 bit1 K2 (H 2) bit9 K512(H 2) bit2 K4 (H 4) bit1 K124(H 4) bit3 K8 (H 8) CH1 bit11 K248(H 8) bit4 K16 (H 1) CH2 bit12 K496(H 1) bit5 K32 (H 2) CH3 bit13 K8192(H 2) b ~ b13 1 PID CR# CH1 CH2 CH3 CH4 #12 #14 #16 #18 O R/W K #121 #141 #161 #181 O R/W (s) K1 ~ K3 (s)k2 #122 #142 #162 #182 O R/W K P K121 #123 #143 #163 #183 O R/W K I K2,98 #124 #144 #164 #184 O R/W K D K-29 #125 #145 #165 #185 O R/W K #126 #146 #166 #186 O R/W K #127 #147 #167 #187 X R #128 #148 #168 #188 O R/W #129 #149 #169 #189 O R/W #13 #15 #17 #19 O R/W H H 1 H K-32,76 ~ K32,76 K32, K-32,76 ~ K32,76 K #131 #151 #171 #191 X R K ~ K1,.1% #132 #152 #172 #192 X R (ms) ms #133 #153 #173 #193 X R (ms) ms #134 #154 #174 #194 X R #135 #155 #175 #195 X R/W PID_Run/Stop H StopH 1RunK #136 #156 #176 #196 X R/W Auto-tuning H H 1Auto-tuning K O CR#41H 5678X RFROMWTO
19 D99 ~ D9999 DVP-ES2I/OD99 ~ D9999MOV D99 ~ D9999 DVP-ES2DVP4TC-E D132 D1321 D1322 D1323 D1324 D1325 D1326 D1327 D99 D991 D992 D993 D994 D995 D996 D997 D991 D9911 D9921 D9931 D9941 D9951 D9961 D9971 D992 D9912 D9922 D9932 D9942 D9952 D9962 D9972 D993 D9913 D9923 D9933 D9943 D9953 D9963 D9973 I/O CH1 CH2 CH3 CH4 D99 ~ D9999 WPLSoftFROM/TO (CR#8 ~ CR#11) 1 TC Offset(CR#28~CR#31) Offset ~ mV = 8mV/8 6 J-type 1K-type +11,5 (+21,2) +13,5 (+24,62) -1 C (-148 F) +1,15 C (+2,12 F) -1,(-1,48) 2R-type 3S-type +17,5 (+31,82) -1 C (-148 F) +1,35 C (+2,462 F) -1,(-1,48) 4T-type +3,9 (+7,34) C (-32 F) (-32) +1,75 C (+3,182 F) -15 C (-238 F) +39 C (+734 F) -1,5(-2,38)
20 5E-type +9,8 (+17,96) 6N-type +12,8 (+23,36) -15 C (-238 F) +98 C (+1,796 F) -1,5(-2,38) -15 C (-238 F) +1,28 C (+2,336 F) -1,5(-2,38) of CR#2~ CR#5-1 C ~ 115 C (-1~115) -148 F ~ 212 F (-148~212) 1 of CR#2~ CR#5-1 C ~ 135 C (-1~135) -148 F ~ 2462 F (-148~2462) 2, 3 of CR#2~ CR#5 C ~ 175 C (~175) 32 F ~ 3182 F (32~3182) 4 of CR#2~ CR#5-15 C ~ 39 C (-15~39) -238 F ~ 734 F (-238~734) 5 of CR#2~ CR#5-15 C ~ 98 C (-15~98) -238 F ~ 1796 F (-238~1796) 6 of CR#2~ CR#5-15 C ~ 128 C (-15~128) -238 F ~ 2336 F (-238~2336) Offset (CR#34 ~ CR#37) 7 +8, -8mV 7 of CR#2~ CR#5-8mV~+8mV (-8~8) +8mV -8, Offset (CR#34 ~ CR#37) mv
Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.
Safety Precautions Observe the following notices to ensure personal safety or to prevent accidents. To ensure that you use this product correctly, read this User s Manual thoroughly before use. Make sure
More informationISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER
ISOCON-6 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting
More informationtechnical bulletin Installation Instructions: Wall-Mount Dewpoint Probe ( )
Installation Instructions: Wall-Mount Dewpoint Probe (809-2011) The HMW90 Wall-Mount Dewpoint Probe (P/N 809-2011) HMW90 measures dewpoint for indoor applications such as anti-sweat heater control and
More informationBMXART0814 analog input module M340-8 inputs - temperature
Product data sheet Characteristics BMXART0814 analog input module M340-8 inputs - temperature Main Range of product Product or component type Electrical connection Input output isolation Input level Analogue
More informationISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER
ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER CAUTION: This equipment is designed for connection to mains voltages and must be used in accordance with this guide. If it is not, the safety protection
More informationOPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000
3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER Model : TM-2000 Your purchase of this THERMOMETER marks a step forward for you into the field of precision measurement. Although this THERMOMETER is a
More informationBMXART0814 analog input module M340-8 inputs - temperature
Characteristics analog input module M340-8 inputs - temperature Complementary Analog/Digital conversion Analogue input resolution Input impedance Permitted overload on inputs Common mode rejection Differential
More informationThe Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:
The basic PC software is supplied free with the recorder. There is an additional charge for the extensive Data Acquisition Software supplied with communication of RS-232/422/485 or Ethernet. The Ordering
More informationSINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol
with PROFIBUS-PA procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application 00 II () G FISCO The SINEAX VK 66 is a temperature transducer for use in aumation systems
More informationBMXART0814 analog input module M340-8 inputs - temperature
Product data sheet Characteristics BMXART0814 analog input module M340-8 inputs - temperature Product availability : Stock - Normally stocked in distribution facility Price* : 1485.00 USD Main Range of
More informationCHV Series Vector Control Inverter Options. Operating Instructions for Tension Control Card
CHV Series Vector Control Inverter Options Operating Instructions for Control Card 1. Model and Specifications 1.1 Model The model of tension card is CHV00ZL. CHV series inverter can conduct constant
More informationDS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.
DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link
More informationAcceleration/Velocity/Displacement VIBRATION METER
Acceleration/Velocity/Displacement VIBRATION METER Model : VB-8220 Your purchase of this VIBRATION METER marks a step forward for you into the field of precision measurement. Although this METER is a complex
More information1) Thermo couple sensor
1) Thermo couple sensor Fundamental operation. In 1821 Mr. Seebeck found that if you connected 2 wires of different metals, a small Voltage would be generated, when this connection (junction) is heated.
More informationFATEK. FBs-1HLC. Precision Load Cell Module. Operation manual V1.1 06/07/2017 FATEK AUTOMATION CORP.
FATEK FBs-1HLC Precision Load Cell Module Operation manual V1.1 06/07/2017 FATEK AUTOMATION CORP. 1 Contents Chapter 1 1HLC module introduction... 3 1.1 Module specification... 3 1.2 Module appearance
More informationOperating Instructions for Digital Manometer. Model: MAN-SD
Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5
More informationProximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C
ASH & ALAIN INDIA PVT LTD S-00, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-000(India) Tel : 0-797575 Fax : 0-79757 E-mail : sales@ashalain.com Proximity Ideal for High Temperatures and Cleaning
More informationRemote Display Unit. Installers Handbook Copyright 2001 AirSense Technology Ltd. LM Remote Display Unit Installers Handbook Issue 1.
Remote Display Unit Installers Handbook Copyright 2001 AirSense Technology Ltd AirSense, ClassiFire, FastLearn PipeCAD, SenseNET, Stratos-HSSD and Stratos-Quadra are trademarks. HSSD is a Registered Trademark.
More informationTF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels
TF 0 / TF 0-Ex Field mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.69 EN USA Input Resistance thermometer (,, wire circuit) Thermocouples
More informationDATA SHEET. Thermocouple module with digital I²C-Interface - THMOD-I²C. Characteristic features. Areas of application. Features.
Description Characteristic features Industrial temperature measuring method Wide measuring range, -270...+1360 C Digital I²C-interface Simple integration to micro-controller Scope of supply with thermocouple,
More informationUser Manual VX4750 Function Generator Module
User Manual VX4750 Function Generator Module 070-9151-05 This document applies for firmware version 2.60 and above. Copyright Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S.
More informationPHASED OUT. FL ballasts Electronic dimming. PCA TC BASIC Y II, W BASIC compact
EL Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A BAT Noise-free precise control via DSI signal, switchdim or corridorfunction Nominal life
More informationInstallation Instructions: ICON Anti-Condensate Controller
TECHNICAL BULLETIN Installation Instructions: ICON Anti-Condensate Controller System Overview The ICON Anti-Condensate Controller System (pat. pend.) is a stand-alone controller for antisweat heaters in
More informationRequest Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.
Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -A - Introduction - Thank for your purchasing MITSUBISHI ELECTRIC MELPRO TM D Series Digital Protection
More informationINFORMATION TECHNOLOGY SYSTEMS SPDs FOR 19 TECHNOLOGY. NET Protector Surge Arrester. Protects switches, HUBs and telecommunication
Surge Arrester Protects switches, HUBs and telecommunication systems Class D according to EN 0 possible (Gigabit Ethernet) Variably equippable patch panels Units available with plug-in inputs and outputs
More informationSCTP20 Programmable 2-Wire Temperature Transmitter, Head Mount
20 Programmable 2-Wire Temperature Transmitter, Head Mount Configurable Transmitters Description Each 20 2-wire transmitter is designed for measuring temperature using thermocouples or RTDs. The input
More informationPOINTS OF CAUTION BEFORE USE...
INSTRUCTION MANUAL NPN DISCRETE INPUT & NPN TRANSISTOR OUTPUT MODULE, 6 points each (-I/-II, e-con connector) MODEL BEFORE USE... Thank you for choosing M-System. Before use, check the contents of the
More informationAcceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202
Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202 Your purchase of this VIBRATION METER marks a step forward for you into the field of precision measurement. Although this METER is
More informationE6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders
Multi-turn High-precision Encoder Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders Reset function for easy origin alignment when built-into equipment. Multi-turn
More informationMulti-function, economical instrument with 4 functions in the same casing. Accessibility and safety: large-dimension terminals Insulated circuits
200 > Measurement and instrumentation Programmable digital transducers TRIAD 2 range Programmable digital transducers with to 4 analogue outputs Programmable accuracy class PRODUCT ADVANTAGES Up to 4 PROGRAMMABLE
More informationBEFORE USE... POINTS OF CAUTION COMPONENT IDENTIFICATION INSTRUCTION MANUAL MODEL R7K4DH-1-DAC32D R7K4DH-1-DAC32D
INSTRUCTION MANUAL PNP DISCRETE INPUT & PNP TRANSISTOR OUTPUT MODULE, 6 points each (High-speed Link System, e-con connector) R7KDH--DACD MODEL R7KDH--DACD BEFORE USE... Thank you for choosing M-System.
More informationWelcome. Functionality and application of RTD Temperature Probes and Thermocouples. Dipl.-Ing. Manfred Schleicher
Welcome Functionality and application of RTD Temperature Probes and Thermocouples Dipl.-Ing. Manfred Schleicher This presentation informs about the basics of RTD Temperature Probes and thermocouples Functionality
More informationE8EB-N0C2B E8EB-N0B2B
Slim Sensor CSM DS_E 1 Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree
More informationS Sapling INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS. advanced time and control systems
INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS Time base: 60 Hz (3-wire system) Quartz (2-wire system) Power input: 85 135 VAC / 60 Hz 7 28 VAC / 60 Hz Current consumption:
More informationSC125MS. Data Sheet and Instruction Manual. ! Warning! Salem Controls Inc. Stepper Motor Driver. Last Updated 12/14/2004
SC125MS Stepper Motor Driver Salem Controls Inc. Last Updated 12/14/2004! Warning! Stepper motors and drivers use high current and voltages capable of causing severe injury. Do not operate this product
More informationUsing a Mercury itc with thermocouples
Technical Note Mercury Support Using a Mercury itc with thermocouples Abstract and content description This technical note describes how to make accurate and reliable temperature measurements using an
More information16 Input AC Block I/O Module
6 Input AC Module Cat. No. 79-6A0 Series B Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air flow through
More informationTF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.
TF / TF -Ex Field mounted temperature transmitters, PROFIBUS PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN P R O F I PROCESS FIELD BUS B U S Input Resistance thermometer (,, -wire
More informationMicrocare LCD Solar MPPT User Documentation
Microcare LCD Solar MPPT User Documentation 1 CONTENTS 1. INTRODUCTION. 3 1.1. General Description 1.2. Key Features 1.3. Important Notices 1.4. Recommended Array Sizes 1.5. MPPT Description 1.6. MPPT
More informationRequest Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.
Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -C - Safety section - This Safety section should be read before starting any work on the relay.
More informationAN3002 Thermocouple measurement
AN3002 Thermocouple measurement This application note illustrates the correct measurement of thermocouple sensors. Contents 1 Introduction......................................... 3 2 Test configuration....................................
More informationMAGPOWR TENSION CONTROL DLCA NET-SLIM. User Manual. Digital Load Cell Amplifier MI 850A358 1 A
MAGPOWR TENSION CONTROL DLCA NET-SLIM User Manual EN Digital Load Cell Amplifier MI 850A358 1 A CONTENTS 1.0 INTRODUCTION 4 1.1 About these operating instructions... 4 1.2 Product overview... 5 1.2.1 Additional
More informationTHM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist
THM80X Series Feature Application IP67 protection degree, rugged aluminum case, fit in variety harsh environment Capable of temperature compensation Linear adjustment temperature & humidity by computer,
More information473-SHX Dew Point Mirror
Humidity and Temperature Reference Hygrometer For Temperature up to 125 C Precise and stable chilled mirror dew point mirror technology High temperature optical components High temperature sample fan Cable
More informationRef: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000,
Digital Current Transducer HLSR-PW series I P N = 16... 50 A Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000, Bitstream output from on onboard Sigma Delta modulator. For the electronic measurement
More informationTHERMOCOUPLE CHARACTERISTICS TRAINER
THERMOCOUPLE CHARACTERISTICS TRAINER (Model No : ) User Manual Version 2.0 Technical Clarification /Suggestion : / Technical Support Division, Vi Microsystems Pvt. Ltd., Plot No :75,Electronics Estate,
More informationPTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30
eries Features Best pressure transmission solution for small and middle sized project such as indoor heating and air conditioning, water and sewer, or incinerator, etc. Improves noise resistance and minimize
More information473 Dew Point Hygrometer
gh Performance Chilled Hygrometer With Cable Mounted Measuring Heads ghly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct insertion
More informationSingle cam type. Double cam type. Grip force N. Type Model/size Stroke Screw type straight style. Screw type tee style
Type Model/size Stroke -SS-0-N. -SS-0-N. Single cam type -SS- 7. -SS-. -SS-4. -SD-0 Double cam type -SD- -SD-4. Screw type straight style Screw type tee style -FS- -FT- -FS- -FT- 0.9 1. 1.. 1. 4 Grip forcen
More information24 volts (0.25 amps current-limited)
Question 1 Questions Suppose the lamp refuses to light up. A voltmeter registers 24 volts between test points C and D: A C E + 24 volts (0.25 amps current-limited) B D F First, list all the possible (single)
More information32 Input AC Block I/O Module
Input AC Module Cat. No. 79-A0 Series B Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air to flow through
More informationSt art. rp m. Km /h 1: : : : : : : : : : : : :5 2.5.
modified 22/05/14 t 3:5 2.5 3:5 5.0 3:5 7.5 4:0 0.0 4:0 2.5 4:0 5.0 4:0 7.5 4:1 0.0 4:1 2.5 4:1 5.0 4:1 7.5 4:2 0.0 Km /h 0 25 50 75 100 125 150 175 200 225 rp m 0 250 0 500 0 750 0 100 00 125 00 1 2 3
More information473 Dew Point Hygrometer
High Performance Chilled Mirror Hygrometer With Cable Mounted Measuring Heads Highly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct
More informationSINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol
SINEAX VK 66 for RTD and TC inputs, with HART procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application II () G SINEAX VK 66 is a two-wire head-mounted transmitter.
More informationED 701 General Industry Pressure Transmitter
ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More information4.3 Analog Value Representation
4.3 Analog Value Representation Introduction This section describes the analog values for all the measuring ranges and output ranges which you can use with the analog modules. Converting analog values
More informationPascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure
DATASHEET Pascal ET Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure - electrical signals (ma, mv, V, ) - temperature (TC and
More informationT20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en
T20WN Torque transducers Data Sheet Special features - Nominal (rated) torques 0.1 N m, 0.2 N m, 0. N m, 1 N m, 2 N m, N m, 10 N m, 20 N m, 0 N m, 100 N m, 200 N m - Accuracy class: 0.2 - Contactless transmission
More informationPHOENIX CONTACT - 04/2016. Features
Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.
More informationAmerican Zettler AZ742 RELAY Datasheet
American Zettler AZ74 RELAY Datasheet http://www.manuallib.com/american-zettler/az74-relay-datasheet.html FEATURES Dielectric strength 000 Vrms Low height:.7 mm Epoxy sealed version available 0 Amp switching
More informationO P E R A T I N G M A N U A L
OPERATING MANUAL WeatherJack OPERATING MANUAL 1-800-645-1061 The baud rate is 2400 ( 8 bits, 1 stop bit, no parity. Flow control = none) To make sure the unit is on line, send an X. the machine will respond
More informationAKD SYSTEM CONFIGURATION WITH KOLLMORGEN DDL LINEAR MOTORS By Kenny Hampton 1/12/2017 Rev. L
AKD SYSTEM CONFIGURATION WITH KOLLMORGEN DDL LINEAR MOTORS By Kenny Hampton 1/12/2017 Rev. L This document shows the wiring requirements for connecting the DDL linear motors to the AKD servo drive. It
More informationCVS Calibration System CVS-KAL. Short Instruction Manual. System Configuration Description of the Equipment
CVS Calibration System Short Instruction Manual System Configuration Description of the Equipment State: 11/21/2005 Table of contents 1. Documentation and Appropriate Usage 2. EC Conformity Declaration
More informationSolar cells E Introduction. Equipment used for this experiment is displayed in Fig. 2.1.
2.0 Introduction Equipment used for this experiment is displayed in Fig. 2.1. Figure 2.1 Equipment used for experiment E2. List of equipment (see Fig. 2.1): A: Solar cell B: Solar cell C: Box with slots
More informationMODEL 107 TEMPERATURE PROBE INSTRUCTION MANUAL
MODEL 107 TEMPERATURE PROBE INSTRUCTION MANUAL REVISION: 6/00 COPYRIGHT (c) 1983-2000 CAMPBELL SCIENTIFIC, INC. This is a blank page. Warranty and Assistance The MODEL 107 TEMPERATURE PROBE is warranted
More informationHigh Resolution High Sensitivity SDR Super Wide Dynamic Camera
High Resolution High Sensitivity SDR Super Wide Dynamic Camera INSTRUCTION MANUAL 15-CA45R 15-CA45RC CONTENTS PRECAUTION.2 FEATURES..3 DIMENSION...3 INSTALLATION...4 SPECIFICATIONS..5 BASIC TECHNICAL DATA
More informationPressure transmitters for industrial applications MBS 32 and MBS 33
Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer
More informationSTATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016
APPLICATIONS Moisture monitoring of air or gas (SF6) Suitable for indoor or outdoor Industrial, medical or aerospace fields HIGHLIGHTS High voltage circuit breakers commonly used for distribution and transmission
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer HO-NP series I P N = 4, 6, 12, 15 A Ref: HO 4-NP, HO 6-NP, HO 12-NP, HO 15-NP For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary
More informationFL ballasts Electronic dimming. PCA TC ECO Y II, W ECO compact
FL ballasts EL TC-F TC-SEL TC-L HE TC-DD Tc PCA TC ECO Y II, 7 W ECO compact Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A BAT Noise-free
More informationPRODUCT SPECIFICATIONS
FEATURES AND BENEFITS* Up to 1,000,000 duty cycles or 10 year DC life 48V DC working voltage Active cell balancing Temperature output Overvoltage outputs available High power density TYPICAL APPLICATIONS
More informationData Logger V2. Instruction Manual
Data Logger V2 Instruction Manual Joe Holdsworth 7-29-2018 Contents Revision History... 2 Specifications... 3 Power Limits... 3 Data Rates... 3 Other Specifications... 3 Pin Outs... 4 AS218-35SN... 4 AS210-35SN...
More informationMODE button MAX/MIN button CHANNEL button / C/ F / RCC button SNOOZE / LIGHT button Battery compartment A/C in-jack 3. 4.
KL4912 Desktop weather station Instruction Manual Introduction This weather station comes with backlight, indoor and outdoor temperature & humidity display, and alarm clock with calendar. Fig. 1 Front
More informationMODEL: MO Digital DC Milliohm Meter OPERATING INSTRUCTION
MODEL: MO-1210 Digital DC Milliohm Meter OPERATING INSTRUCTION Index 1. Introduction...1 1-1.Brief...1 1-2.Features...1 1-3.Specification...1 2.Machine...4 2-1.Panel......4 2-2.LCD............4 3.Operation...5
More informationCR10TCR THERMOCOUPLE REFERENCE
CR10TCR THERMOCOUPLE REFERENCE REVISION: 12/96 COPYRIGHT (c) 1995-1996 CAMPBELL SCIENTIFIC, INC. This is a blank page. WARRANTY AND ASSISTANCE The CR10TCR THERMOCOUPLE REFERENCE is warranted by CAMPBELL
More informationRoHS. Versatile. X g. X 2 e
s IN8, - and The inclinometers of the IN8 series allow measuring inclinations in the range of ±85 or -dimensional inclinations up to 0. With their high robustness, their protection level up to max. IP9k
More informationSECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:
SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer LDSR 0.3-TP/SP1 I P R N = 300 ma For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Closed
More informationMinimum (-31) every 10 s -35 (-31)
Humidity, and Dew Point Data Logger with LCD ORDERING INFORMATION Standard Data Logger (Data Logger, Software on CD, Battery) Replacement Battery EL-USB-2-LCD BAT 3V6 1/2AA FEATURES 0 to 100 measurement
More informationAIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL
AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL FILE No. A10-023-1 REVISION 1 : Mar.2012 Re-edit version.( file volume down) Contents have NOT been changed. Model name: RAS-M10PKVP-E RAS-M13PKVP-E RAS-M16PKVP-E
More informationInstruction. Vacuum Circuit Breaker Operator Module. Type 3AH 4.16kV to 38kV. Power Transmission & Distribution
Instruction 0001-22-2--00 Vacuum Circuit Breaker Operator Module Type 3AH 4.16kV to 38kV Power Transmission & Distribution Hazardous voltages and high-speed moving parts. Will cause death, serious injury
More informationTemperature Compensation for the 71M651x/651xH, 71M652x, and 71M653x Energy Meter ICs
71M651x Energy Meter ICs A Maxim Integrated Products Brand APPLICATION NOTE AN_651X_009 MAY 2010 Temperature Compensation for the 71M651x/651xH, 71M652x, and 71M653x Energy Meter ICs Meters based on the
More informationKTBCD430-D1. Product. Bi-stable Cholesteric Display Module 128 x 64 Dots Matrix Build In Voltage Booster
PAGE 1 OF 15 KTBCD430-D1 Product Bi-stable Cholesteric Display Module 128 x 64 Dots Matrix Build In Voltage Booster Kentec Electronics (Displays) Limited URL: http://www.kentec.com.hk E-mail: t.liang@kentec.com.hk;
More informationDMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output
More informationCircular Motion and Centripetal Force
[For International Campus Lab ONLY] Objective Measure the centripetal force with the radius, mass, and speed of a particle in uniform circular motion. Theory ----------------------------- Reference --------------------------
More informationNTE74HC299 Integrated Circuit TTL High Speed CMOS, 8 Bit Universal Shift Register with 3 State Output
NTE74HC299 Integrated Circuit TTL High Speed CMOS, 8 Bit Universal Shift Register with 3 State Output Description: The NTE74HC299 is an 8 bit shift/storage register with three state bus interface capability
More informationLinear measuring technology
Their extremely robust construction, their high IP69k protection level and their wide temperature range make these new draw wire encoders particularly reliable and durable. Their flexibility and adaptability
More informationMinute Impulse Clock Controller I01DN
99b-mi USER S MANUAL Minute Impulse Clock Controller Mon Jun 01, 2009 12:00:00 PM DST HOLD ENTER KEY TO BEGIN CANCEL HR I01DN 97 West Street Medfield, MA 02052 U.S.A. (508) 359-4396 Pg. 2 of 20 TABLE OF
More informationPRODUCT SPECIFICATIONS
FEATURES AND BENEFITS* Up to 14 year DC life 56V DC working voltage Resistive cell balancing Overvoltage outputs High power density 4U, half-rack package UL registered TYPICAL APPLICATIONS UPS systems
More informationHD2016. [ GB ] Weighing rain gauge. Rain PART OF G H M GROUP TELEMETRIE & AUTOMATION TELEMETRIE & AUTOMATION
HD2016 [ GB ] Weighing rain gauge Rain PART OF G H M GROUP TELEMETRIE & AUTOMATION TELEMETRIE & AUTOMATION [ GB ] HD2016 Weighing rain gauge [ GB ] HD2016 is a rain gauge that detects the weight of the
More informationSeries CCT-58S Multi-Throw DC 18 GHz, SP7T & SP8T Normally Open Coaxial Switch
PART NUMBER CCT-58S DESCRIPTION Commercial Normally Open Multi-throw, DC-18 GHz The CCT-58S/CT-58S is an internally terminated, broadband, multi-throw, electromechanical coaxial switch designed to switch
More informationDIGITAL THERMOMETER OPERATOR S MANUAL
DIGITAL THERMOMETER OPERATOR S MANUAL 51 206-3722 52 206-3738 DIGITAL THERMOMETER OPERATOR'S MANUAL RS 51 206-3722 RS 52 206-3738 1 2 INTRODUCTION 1-1 Unpacking and Inspection Upon removing your new Digital
More informationEmergency lighting units EM Inverter
T T TC- TC-F DE TC- TC-SE TC-TE TC-DD Tc EM G, 0 0 V 0/0 Hz BASIC version Product description Emergency lighting supply unit for manual testing For linear and compact fluorescent lamps ow-profile casing
More informationContents. Technical Information. Tips on Recorder Measurement Accuracy TI 04D05B01-90EN
Technical Information Tips on Recorder Measurement Accuracy TI 04D05B01-90EN Contents 1. Expressing accuracy...1 1.1 What is accuracy?...1 1.2 Accuracy expression for µr series recorders...1 2. Measurement
More informationVIBRATION METER. Instruction Manual.
VIBRATION METER 840063 Instruction Manual CONTENTS Title Page I. Introduction... 2 II. Panel Description... 3 III. Operating Instructions A. General Measurement Procedures... 3~4 B. Peak... 5 C. Data Hold...
More informationSwegon CASA Smart ModBus Register SCB 3.0
USER SETTINGS 3.0-> 4x5001 RW Operating Mode 0 4 0= Stopped, 1 = Away, 2 = Home, 3 = Boost, 4 = Travelling 3.0-> 4x5019 RW Smart Control -100 100 % Smart control Increase or decrease Ventilation level
More informationEA Guidelines on the Calibration of Temperature Indicators and Simulators by Electrical Simulation and Measurement
Publication Reference EA-10/11 EA Guidelines on the Calibration of Temperature Indicators and Simulators by Electrical PURPOSE This document has been produced by EA as a means of giving advice for calibrating
More informationFL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact
FL ballasts EL HE PC TC PRO sr 1/2x11 42 W PC PRO compact Product description CELMA Energy Efficiency Index A2 BAT / A2 T Nominal life-time up to 50,000 h (at ta 50 C with a failure rate max. 0.2 % per
More informationPCAN-MicroMod Evaluation Kit. Test and Development Environment for the PCAN-MicroMod. User Manual
Test and Development Environment for the PCAN-MicroMod Products taken into account Product Name Item Number Model PCAN-MicroMod Evaluation Kit (incl. PCAN-Dongle) PCAN-MicroMod Evaluation Kit (incl. PCAN-USB)
More informationVIBRATION METER Acceleration & Velocity Model : VB-8201HA
VIBRATION METER Acceleration & Velocity Model : VB-8201HA TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS...2 3. FRONT PANEL DESCRIPTION...4 3-1 Display...4 3-2 BNC socket of meter...4 3-3 RMS/PEAK
More information