POINTS OF CAUTION BEFORE USE...

Size: px
Start display at page:

Download "POINTS OF CAUTION BEFORE USE..."

Transcription

1 INSTRUCTION MANUAL NPN DISCRETE INPUT & NPN TRANSISTOR OUTPUT MODULE, 6 points each (-I/-II, e-con connector) MODEL BEFORE USE... Thank you for choosing M-System. Before use, check the contents of the package you received as outlined below. If you have any problems or questions with the product, please contact M-System s Sales Office or representatives. PACKAGE ILUDES Discrete I/O module... () Surface mounter slider... () MODEL NO. Confirm that the model number described on the product is exactly what you ordered. INSTRUCTION MANUAL This manual describes necessary points of caution when you use this product, including installation, connection and basic maintenance procedures. POINTS OF CAUTION CONFORMITY WITH EC DIRECTIVE The actual installation environments such as panel configurations, connected devices and connected wires may affect the protection level of this unit when it is integrated in a panel system. The user may have to review the CE requirements in regard to the whole system and employ additional protective measures to ensure CE conformity. POWER INPUT RATING & OPERATIONAL RANGE Locate the power input rating marked on the product and confirm its operational range as indicated below V DC rating V ±0%, approx. 7mA REMOVING THE UNIT Before you remove the unit or mount it, turn off the power supply and input signal for safety. ENVIRONMENT Indoor use When heavy dust or metal particles are present in the air, install the unit inside proper housing with sufficient ventilation. Do not install the unit where it is subjected to continuous vibration. Do not apply physical impact to the unit. Environmental temperature must be within 0 to + C ( to F) with relative humidity within 0 to 90% RH in order to ensure adequate life span and operation. WIRING Do not install cables close to noise sources (relay drive cable, high frequency line, etc.). Do not bind these cables together with those in which noises are present. Do not install them in the same duct. AND... The unit is designed to function as soon as power is supplied, however, a warm up for 0 minutes is required for satisfying complete performance described in the data sheet. P. / 8

2 06789ABCDEF 06789ABCDEF COMPONENT IDENTIFICATION FRONT VIEW Status Indicator LED Station Address Setting Rotary SW I/O Connector Discrete I/O Status Indicator LED Power Supply Sensor Exc. Connector PWR ERR RD SD STATION ADD. 0 X0 X X X X X X6 X7 X8 X9 XA XB XC XD XE XF X0 6 7 X8 9 A B C D E F Y0 6 7 SW Y8 9 A B C D E F ON Y0 Y Y Y Y Y Y6 Y7 Y8 Y9 YA YB YC YD YE YF Connector Operating Mode Setting DIP SW (SW) STATUS INDICATOR LED ID COLOR FUTION PWR ERR SD RD Green Red Green Green Turns on when internal power is supplied normally, and off with internal power failure. Turns on with station address setting error, and off with normal station address setting. Turns on when transmitting data, and off when not transmitting data. Turns on when receiving data, and off when not receiving data. DISCRETE I/O STATUS INDICATOR LED LED green indicators show each I/O signal status. ON LED ON OFF LED OFF STATION ADDRESS The left switch determines the upper digit, while the right switch does the lower digit of the station address (hexadecimal number). (Range 60H to 7FH)* (Factory setting 6H) MODE Set either -I or -II, and the data size with SW- and SW-. SW- SW- OFF OFF -II ( byte mode) (*) ON OFF -II (7 byte mode) ON ON -I (7 byte mode) (*) Factory setting Caution! - Since SW- and SW- are unused, be sure to turn them off. POWER SUPPLY, SENSOR EXCITATION Cable connector FMC, / STF, (Phoenix Contact) (included in the package) Applicable wire size 0.. mm ; stripped length 0 mm Recommended solderless terminal AI0, 0YE 0. mm (Phoenix Contact) AI0, 0TQ 0. mm (Phoenix Contact) AI0, 0WH 0. mm (Phoenix Contact) AI0,7 0GY 0.7 mm (Phoenix Contact) A 0.0 mm (Phoenix Contact) A, 0. mm (Phoenix Contact). PWR+. PWR. FE. SNSR.EXC+. SNSR.EXC Power Supply ( V DC) Power Supply (0 V) Functional earth Sensor excitation ( V DC) Sensor excitation (0 V) Station Address Setting (x) Station Address Setting (x6) * As R7KDML is simple I/O, set the station address within the range from 60H to 7FH. Refer to the instruction mannual of the master unit for unselectable addresses, which depending on master unit types. P. / 8

3 TERMINAL ASSIGNMENTS I/O Connection Recommended cable connector 70-( )-000FL (M Company) (The cable connector is not included in the package. Specify wire size instead of ( ); refer to the specifications of the product.) X0 X X X X X X6 X7 X8 X9 XA XB XC XD XE XF Y0 Y Y Y Y Y Y6 Y7 Y8 Y9 YA YB YC YD YE YF No. ID FUTION No. ID FUTION No. ID FUTION No. ID FUTION +V V DC +V V DC +V V DC +V V DC X0 Unused Unused Unused Unused X8 Y0 Y8 GND 0V GND 0V Unused Unused X0 Input 0 X8 Input 8 Y0 Output 0 Y8 Output 8 +V V DC +V V DC +V V DC +V V DC X Unused Unused Unused Unused X9 Y Y9 GND 0V GND 0V Unused Unused X Input X9 Input 9 Y Output Y9 Output 9 +V V DC +V V DC +V V DC +V V DC X Unused Unused Unused Unused XA Y YA GND 0V GND 0V Unused Unused X Input XA Input 0 Y Output YA Output 0 +V V DC +V V DC +V V DC +V V DC X Unused Unused Unused Unused XB Y YB GND 0V GND 0V Unused Unused X Input XB Input Y Output YB Output +V V DC +V V DC +V V DC +V V DC X Unused Unused Unused Unused XC Y YC GND 0V GND 0V Unused Unused X Input XC Input Y Output YC Output +V V DC +V V DC +V V DC +V V DC X Unused Unused Unused Unused XD Y YD GND 0V GND 0V Unused Unused X Input XD Input Y Output YD Output +V V DC +V V DC +V V DC +V V DC X6 Unused Unused Unused Unused XE Y6 YE GND 0V GND 0V Unused Unused X6 Input 6 XE Input Y6 Output 6 YE Output +V V DC +V V DC +V V DC +V V DC X7 Unused Unused Unused Unused XF Y7 YF GND 0V GND 0V Unused Unused X7 Input 7 XF Input Y7 Output 7 YF Output CONNECTION Master Slave * * terminator SRD+ SRD+ SRD+ SRD+ SRD+ SRD+ terminator Cable Cable * Terminator Be sure to connect the terminating resistors to the unit at both ends of transmission line. Use the terminating resistor dedicated for Model JEPMC-W60, Yaskawa Controls Co., Ltd. Certain types of Master units may have incorporated terminating resistors. Consult the instruction manual for the Master. Slave P. / 8

4 MOUNTING INSTRUCTIONS DIN RAIL MOUNTING Mounting ) Set the upper hook at the rear side of the unit on the DIN rail. ) Push in the lower. SURFACE MOUNTING ) Insert the two DIN rail mounter sliders until it clicks once, as shown below. ) Mount the unit with M screws referring to the EXTER- NAL DIMENSIONS. (Torque. N m) Dismounting ) Push down the DIN rail mounter slider with the tip of a minus screwdriver. ) Pull the lower of the unit. ) Remove the upper hook of the unit from the DIN rail. MOUNTING REQUIREMENTS unit mm (inch) M 0 (8.66) P. / 8

5 TERMINAL CONNECTIONS Connect the unit as in the diagram below. EXTERNAL DIMENSIONS mm (inch) (9.) 0 (8.66) 0 (8.7) (.6) (.0) DIN RAIL mm wide. (.) 0 (.97) (.0) -. dia. deep ( dia. 0.6 deep) [ (.6)] CONNECTION DIAGRAM CN CN Connector Connector +V GND X0 +V GND XF +V Y0 +V YF PWR+ PWR FE SNSR.EXC+ SNSR.EXC + + Detecting Circuit Detecting Circuit OUTPUT Y0 OUTPUT YF POWER SUPPLY (IN) SENSOR EXC. (IN) INPUT X0 INPUT XF -Wire Sensor +V GND Xn Detecting Circuit PWR+ PWR FE SNSR.EXC+ SNSR.EXC POWER SUPPLY (OUT) SENSOR EXC. (OUT) Note In order to improve EMC performance, bond the FE terminal to the ground. Caution FE terminal is NOT a protective conductor terminal. P. / 8

6 COMMUNICATION -I Baud rate Mbps Transmission distance 0 m max. Distance between stations 0 cm min. Transmission media cable (Model JEPMC-W600-x-E, Yaskawa Controls Co., Ltd.) Max. number of slaves (The maximum number of slaves might change depending on the master unit. Refer to the manual of the master unit.) Transmission cycle msec. (fixed) Data length 7 byte -II Baud rate 0 Mbps Transmission distance 0 m max. Distance between stations 0 cm min. Transmission media cable (Model JEPMC-W600-x-E, Yaskawa Controls Co., Ltd.) Max. number of slaves 0 (The maximum number of slaves might change depending on the master unit. Refer to the manual of the master unit.) Transmission cycle 0.msec., 0. msec., msec.,. msec., msec.,. msec., msec., msec., 8 msec. Data length 7 byte / byte selectable (Must choose identical data size for all stations within the network) P. 6 / 8

7 RELATED COMMANDS R7KDML (Simple I/O) communicates with I/O service with no processer, therfore it uses a connectionless communication protocol. There is no application layer either; the R7KDML interchanges I/O data via data link layer. DATA LINK LAYER COMMAND DESCRIPTIONS The following tables explain the two Commands supported by the R7KDML. MDS Command (0H) Data Format BYTE COMMAND RESPONSE REMARKS 0 MDS (0H) S(0) (90H) Message Data Search (MDS) Command Read the ID from slave station(s) S(0) Response to MDS ID All Byte 7 through are always 0 in the -byte mode. These bytes are unavailable for -I and II in the 7-byte mode. CDRW Command (0H) Data Format BYTE COMMAND RESPONSE REMARKS 0 CDRW (0H) ACK (0H) Cyclic Data Read/Write (CDRW) Command Link transmission Acknowledge (ACK) Positive response to CDRW Out Data Lowest In Data Lowest Order of data Little Endian Out Data Highest In Data Highest 7 Out Data Highest In Data Highest Byte7through are unavailable for -I and -II in the 7-byte mode. (Only available for -II in the -byte mode) P. 7 / 8

8 I/O DATA DESCRIPTIONS 7-BYTE MODE 6 points input data Byte Bit7 Bit6 Bit Bit Bit Bit Bit Bit0 In7 In6 In In In In In In0 In In In In In In0 In9 In BYTE MODE 6 points input data Byte Bit7 Bit6 Bit Bit Bit Bit Bit Bit0 In7 In6 In In In In In In0 In In In In In In0 In9 In points output data Byte Bit7 Bit6 Bit Bit Bit Bit Bit Bit Out7 Out6 Out Out Out Out Out Out0 6 Out Out Out Out Out Out0 Out9 Out8 6 points output data Byte Bit7 Bit6 Bit Bit Bit Bit Bit Bit Out7 Out6 Out Out Out Out Out Out0 Out Out Out Out Out Out0 Out9 Out8 0 OFF, ON At the loss of communication, output is hold. (last data correctly received is hold) P. 8 / 8

BEFORE USE... POINTS OF CAUTION COMPONENT IDENTIFICATION INSTRUCTION MANUAL MODEL R7K4DH-1-DAC32D R7K4DH-1-DAC32D

BEFORE USE... POINTS OF CAUTION COMPONENT IDENTIFICATION INSTRUCTION MANUAL MODEL R7K4DH-1-DAC32D R7K4DH-1-DAC32D INSTRUCTION MANUAL PNP DISCRETE INPUT & PNP TRANSISTOR OUTPUT MODULE, 6 points each (High-speed Link System, e-con connector) R7KDH--DACD MODEL R7KDH--DACD BEFORE USE... Thank you for choosing M-System.

More information

MODEL: R7K4FML3. Remote I/O R7K4F Series. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.)

MODEL: R7K4FML3. Remote I/O R7K4F Series. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.) Remote I/O R7KF Series I/O MODULE (-III) POWER INPUT DC power R: V DC (Operational voltage range: ±0 %; ripple 0 %p-p max.) 0 (8.7). (.) 7(.8) mm (inch) [] OPTIONS (multiple selections) Output data read

More information

MODEL: R7FN. Remote I/O R7 Series FLEX NETWORK I/O MODULE

MODEL: R7FN. Remote I/O R7 Series FLEX NETWORK I/O MODULE MODEL: RFN Remote I/O R Series FLEX NETWORK I/O MODULE /C0: Rubber coating EX-FACTORY SETTING /SET: Preset according to the Ordering Information Sheet (No. ESU-0-x) ORDERING INFORMATION Basic module: RFN-[]-R[]

More information

MODEL: R7M. Remote I/O R7 Series MODBUS I/O MODULE

MODEL: R7M. Remote I/O R7 Series MODBUS I/O MODULE MODEL: RM Remote I/O R Series MODBUS I/O MODULE RS: RTD input, points MS: Potentiometer input, points (Option /UL Not selectable) CTE: AC current input, points, Clamp-on current sensor CLSE use (Option

More information

PHOENIX CONTACT - 04/2016. Features

PHOENIX CONTACT - 04/2016. Features Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.

More information

32 Input AC Block I/O Module

32 Input AC Block I/O Module Input AC Module Cat. No. 79-A0 Series B Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air to flow through

More information

16 Input AC Block I/O Module

16 Input AC Block I/O Module 6 Input AC Module Cat. No. 79-6A0 Series B Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air flow through

More information

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER ISOCON-6 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting

More information

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product. Safety Precautions Observe the following notices to ensure personal safety or to prevent accidents. To ensure that you use this product correctly, read this User s Manual thoroughly before use. Make sure

More information

Acceleration/Velocity/Displacement VIBRATION METER

Acceleration/Velocity/Displacement VIBRATION METER Acceleration/Velocity/Displacement VIBRATION METER Model : VB-8220 Your purchase of this VIBRATION METER marks a step forward for you into the field of precision measurement. Although this METER is a complex

More information

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER CAUTION: This equipment is designed for connection to mains voltages and must be used in accordance with this guide. If it is not, the safety protection

More information

technical bulletin Installation Instructions: Wall-Mount Dewpoint Probe ( )

technical bulletin Installation Instructions: Wall-Mount Dewpoint Probe ( ) Installation Instructions: Wall-Mount Dewpoint Probe (809-2011) The HMW90 Wall-Mount Dewpoint Probe (P/N 809-2011) HMW90 measures dewpoint for indoor applications such as anti-sweat heater control and

More information

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet: abc instruments international FLT5A Thermometer Land Instruments International Dronfield, S18 1DJ England Telephone: (1246) 417691 Facsimile: (1246) 41585 Email: infrared.sales@landinst.com Internet: www.landinst.com

More information

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO. DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link

More information

Weather Station P03/3-Modbus-GPS for Modbus

Weather Station P03/3-Modbus-GPS for Modbus Weather Station P03/3-Modbus-GPS for Modbus Technical specifications and installation instructions Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D-75391 Gechingen Germany Phone: +49

More information

SC125MS. Data Sheet and Instruction Manual. ! Warning! Salem Controls Inc. Stepper Motor Driver. Last Updated 12/14/2004

SC125MS. Data Sheet and Instruction Manual. ! Warning! Salem Controls Inc. Stepper Motor Driver.   Last Updated 12/14/2004 SC125MS Stepper Motor Driver Salem Controls Inc. Last Updated 12/14/2004! Warning! Stepper motors and drivers use high current and voltages capable of causing severe injury. Do not operate this product

More information

Meteorological Station P03/3-RS485-WAGO

Meteorological Station P03/3-RS485-WAGO Meteorological Station P03/3-RS485-WAGO Technical data and notes for installation Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D-75391 Gechingen Germany Phone: +49 (0) 70 56/93 97-0

More information

Operating Instructions for Digital Manometer. Model: MAN-SD

Operating Instructions for Digital Manometer. Model: MAN-SD Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5

More information

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows: The basic PC software is supplied free with the recorder. There is an additional charge for the extensive Data Acquisition Software supplied with communication of RS-232/422/485 or Ethernet. The Ordering

More information

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C ASH & ALAIN INDIA PVT LTD S-00, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-000(India) Tel : 0-797575 Fax : 0-79757 E-mail : sales@ashalain.com Proximity Ideal for High Temperatures and Cleaning

More information

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual Latest generation testo air velocity & IAQ probes with cable handle Instruction manual Contents Contents 1 About this document... 5 2 Safety and disposal... 5 3 System description... 6 4 Description of

More information

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820 Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820 Your purchase of this PEN VIBRATION METER marks a step forward for you into the field of precision measurement.

More information

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202 Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202 Your purchase of this VIBRATION METER marks a step forward for you into the field of precision measurement. Although this METER is

More information

Installation Instructions: ICON Anti-Condensate Controller

Installation Instructions: ICON Anti-Condensate Controller TECHNICAL BULLETIN Installation Instructions: ICON Anti-Condensate Controller System Overview The ICON Anti-Condensate Controller System (pat. pend.) is a stand-alone controller for antisweat heaters in

More information

Installation guide 862 MIT / MIR

Installation guide 862 MIT / MIR Installation guide 862 MIT / MIR in combination with: 864 MTT or 863 MRT or (dual) spot element November 2005 Part no. 4416.232_Rev3 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100

More information

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820 Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820 Your purchase of this PEN VIBRATION METER marks a step forward for you into the field of precision measurement.

More information

Linear measuring technology

Linear measuring technology Their extremely robust construction, their high IP69k protection level and their wide temperature range make these new draw wire encoders particularly reliable and durable. Their flexibility and adaptability

More information

S Sapling INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS. advanced time and control systems

S Sapling INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS. advanced time and control systems INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS Time base: 60 Hz (3-wire system) Quartz (2-wire system) Power input: 85 135 VAC / 60 Hz 7 28 VAC / 60 Hz Current consumption:

More information

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

FATEK. FBs-1HLC. Precision Load Cell Module. Operation manual V1.1 06/07/2017 FATEK AUTOMATION CORP.

FATEK. FBs-1HLC. Precision Load Cell Module. Operation manual V1.1 06/07/2017 FATEK AUTOMATION CORP. FATEK FBs-1HLC Precision Load Cell Module Operation manual V1.1 06/07/2017 FATEK AUTOMATION CORP. 1 Contents Chapter 1 1HLC module introduction... 3 1.1 Module specification... 3 1.2 Module appearance

More information

BMXART0814 analog input module M340-8 inputs - temperature

BMXART0814 analog input module M340-8 inputs - temperature Product data sheet Characteristics BMXART0814 analog input module M340-8 inputs - temperature Main Range of product Product or component type Electrical connection Input output isolation Input level Analogue

More information

E2T0 DVP

E2T0 DVP 29-5-26 5116868-E2T DVP-11363-1 ENGLISH Thank you for choosing Delta s DVP series PLC. DVP4TC-E2 temperature measurement module receives 4 points of external thermocouple temperature sensors (J-type, K-type,

More information

NOVALYNX CORPORATION MODEL 110-WS-16BP BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL

NOVALYNX CORPORATION MODEL 110-WS-16BP BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL NOVALYNX CORPORATION MODEL 110-WS-16BP BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL REVISION DATE: OCT 2005 Receiving and Unpacking Carefully unpack all components and compare to the packing list. Notify

More information

VIBRATION METER Acceleration & Velocity Model : VB-8201HA

VIBRATION METER Acceleration & Velocity Model : VB-8201HA VIBRATION METER Acceleration & Velocity Model : VB-8201HA TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS...2 3. FRONT PANEL DESCRIPTION...4 3-1 Display...4 3-2 BNC socket of meter...4 3-3 RMS/PEAK

More information

Weather Station P03/3-RS485 with RS485 Interface

Weather Station P03/3-RS485 with RS485 Interface Weather Station P03/3-RS485 with RS485 Interface Technical data and notes for installation Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D-75391 Gechingen Germany Phone: +49 (0) 70

More information

Digital display Pressure range ON/OFF output Linear output Model No Positive pressure 0 to 98 kpa (0 to 1 kgf/cm 2 ) NPN open collector o 1 to o5

Digital display Pressure range ON/OFF output Linear output Model No Positive pressure 0 to 98 kpa (0 to 1 kgf/cm 2 ) NPN open collector o 1 to o5 Pressure Sensor E8CC with Built-in Microcomputer and Digital Display and New E8CB General-purpose Model Withstands a of 490 kpa (5 kgf/cm 2 ) and highly reliable. Incorporates a two-turn adjuster ensuring

More information

Differential Pressure Sensor

Differential Pressure Sensor Differential Pressure Sensor MDP200 Series Features Pressure range up to ±500Pa with high accuracy of ±3.0% m.v. Pressure based on thermal micro-flow measurement Outstanding hysteresis and repeatability

More information

D5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder

D5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder with incremental encoder Draw wire encoder A40 Traverse speed max. 0.8 m/s The draw wire system A40 with incremental encoder excels with its compact construction. RoHS Compact and simple Measuring length

More information

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30 eries Features Best pressure transmission solution for small and middle sized project such as indoor heating and air conditioning, water and sewer, or incinerator, etc. Improves noise resistance and minimize

More information

Secured Series Front End Reader Installation Instructions Proximity Reader (ProxPro, ProxPro w/keypad, MiniPro, Thinline II)

Secured Series Front End Reader Installation Instructions Proximity Reader (ProxPro, ProxPro w/keypad, MiniPro, Thinline II) Secured Series Front End Reader Installation Instructions Proximity Reader (ProxPro, ProxPro w/keypad, MiniPro, Thinline II) Installation Procedure: Step 1: Check the Packing List Step 2: Mount the Proximity

More information

Multichannel Brake Infrared Temperature Sensor - Datasheet

Multichannel Brake Infrared Temperature Sensor - Datasheet The Izze-Racing Multichannel Brake Infrared Temperature Sensor is specifically designed to measure the highly transient surface temperature of a brake rotor at multiple points, making it possible to acquire

More information

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER Model : TM-2000 Your purchase of this THERMOMETER marks a step forward for you into the field of precision measurement. Although this THERMOMETER is a

More information

OPERATING MANUAL. EIB-Kombisensor AS 315 N

OPERATING MANUAL. EIB-Kombisensor AS 315 N EIB-Kombisensor AS 315 N OPERATING MANUAL EIB-Kombisensor AS 315 N 1 Contents Page 3 1. Description 4 1.1 Automated Operations 1.1.1 Sun System 1.1.2 Half-Light System 5 1.1.3 Wind System 1.1.4 Rain System

More information

Weather Station P03/3-RS485-GPS with RS485 Interface

Weather Station P03/3-RS485-GPS with RS485 Interface Weather Station P03/3-RS485-GPS with RS485 Interface Technical data and notes for installation Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D-75391 Gechingen Germany Phone: +49 (0)

More information

E6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders

E6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders Multi-turn High-precision Encoder Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders Reset function for easy origin alignment when built-into equipment. Multi-turn

More information

Minute Impulse Clock Controller I01DN

Minute Impulse Clock Controller I01DN 99b-mi USER S MANUAL Minute Impulse Clock Controller Mon Jun 01, 2009 12:00:00 PM DST HOLD ENTER KEY TO BEGIN CANCEL HR I01DN 97 West Street Medfield, MA 02052 U.S.A. (508) 359-4396 Pg. 2 of 20 TABLE OF

More information

Lamp and Control Panel (Lamp Panel)

Lamp and Control Panel (Lamp Panel) www.reinhausen.com Lamp and Control Panel (Lamp Panel) Operating Instructions BA 47/0 EN NOTE! Changes may have been made to a product after going to press with this documentation. We expressly reserve

More information

INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: (50 ), (54 ), or (60 ) Application: All Terrain Vehicles

INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: (50 ), (54 ), or (60 ) Application: All Terrain Vehicles INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: 78950 (50 ), 78954 (54 ), or 78960 (60 ) Application: All Terrain Vehicles Your safety, and the safety of others, is very important. To help you make

More information

No /06e. Technical Manual Multistage-Temperature-/Differential Controller TAR x700

No /06e. Technical Manual Multistage-Temperature-/Differential Controller TAR x700 Technical Manual Multistage-Temperature-/Differential Controller x700 Software Version 0078 o. 5303-0/06e 700 3700 5700 9700 3700 5700 9700 l Suitable as : Multistage Controller or Differential Controller

More information

E8EB-N0C2B E8EB-N0B2B

E8EB-N0C2B E8EB-N0B2B Slim Sensor CSM DS_E 1 Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree

More information

Pressure Transmitter ED 701

Pressure Transmitter ED 701 Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation

More information

xlogic SuperRelay is a compact and expandable CPU replacing mini PLCs, multiple timers, relays and counters.

xlogic SuperRelay is a compact and expandable CPU replacing mini PLCs, multiple timers, relays and counters. SuperRelay S U P E R R E L A Y, T H E P E R F E C T A L T E R N A T I V E T O L O W C O S T P L C s A N D B A S I C R E L A Y S I N T H I S B R O C H U R E : ELC 18 Standard Models ELC 18 Economy Models

More information

14.05 (356,9) (344,2) 2.60 (66,0) 3.00 (76,2) STATUS LED

14.05 (356,9) (344,2) 2.60 (66,0) 3.00 (76,2) STATUS LED RACKS Channel FEATURES For use with Style Controllers Available for Standard, Miniature, G and OpenLine Modules Panel and DIN Rail Mount Versions UL, CSA Certified CHANNEL RACK: Standard Part No. 0RCK

More information

SZ7001. Wireless ZIGBEE tipping bucket rain sensor. Product Overview. Dimensions. parameter. September, 2016 Rev.

SZ7001. Wireless ZIGBEE tipping bucket rain sensor.  Product Overview. Dimensions. parameter. September, 2016 Rev. SZ7001 Wireless ZIGBEE tipping bucket rain sensor http:// www.sonbus.com Product Overview Tipping bucket rain sensor for measuring the nature of rainfall, while rainfall is converted to digital information

More information

SPECIFICATION SHEET : FHS2-UNV-36L

SPECIFICATION SHEET : FHS2-UNV-36L SPECIFICATION SHEET : FHS2-UNV-36L This Is An Original Product From Fulham Co., Inc Description : For Back-up Lighting This driver will operate constant current LED arrays with a working voltage between

More information

MULTI-OUTPUT PROGRAMMABLE CONTROLLERS MODELS UMX-4 & UMX-8

MULTI-OUTPUT PROGRAMMABLE CONTROLLERS MODELS UMX-4 & UMX-8 February 1994 20/20 Interface Products MULTI-OUTPUT PROGRAMMABLE CONTROLLERS MODELS & DESCRIPTION The is a Multi-output Programmable Controller which expands the input or output capability of building

More information

Series CCT-58S Multi-Throw DC 18 GHz, SP7T & SP8T Normally Open Coaxial Switch

Series CCT-58S Multi-Throw DC 18 GHz, SP7T & SP8T Normally Open Coaxial Switch PART NUMBER CCT-58S DESCRIPTION Commercial Normally Open Multi-throw, DC-18 GHz The CCT-58S/CT-58S is an internally terminated, broadband, multi-throw, electromechanical coaxial switch designed to switch

More information

Thermal-Magnetic Circuit Breaker 2210-T2...

Thermal-Magnetic Circuit Breaker 2210-T2... Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring

More information

MODBUS Protocol for CS141 network card families

MODBUS Protocol for CS141 network card families Last update: 20/09/208 MODBUS Protocol for CS4 network card families Summary. MODBUS PROTOCOL... 2.. MODBUS COMMUNICATION PARAMETERS... 2.2. AVAILABLE MODBUS FUNCTION CODES... 2.3. EXCEPTION CODES... 3

More information

XD1-L Cable Differential Protection Relay

XD1-L Cable Differential Protection Relay XD1-L Cable Differential Protection Relay Manual XD1-L (Revision B) Woodward Manual XD1-L GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information

More information

MAGPOWR TENSION CONTROL DLCA NET-SLIM. User Manual. Digital Load Cell Amplifier MI 850A358 1 A

MAGPOWR TENSION CONTROL DLCA NET-SLIM. User Manual. Digital Load Cell Amplifier MI 850A358 1 A MAGPOWR TENSION CONTROL DLCA NET-SLIM User Manual EN Digital Load Cell Amplifier MI 850A358 1 A CONTENTS 1.0 INTRODUCTION 4 1.1 About these operating instructions... 4 1.2 Product overview... 5 1.2.1 Additional

More information

473 Dew Point Hygrometer

473 Dew Point Hygrometer gh Performance Chilled Hygrometer With Cable Mounted Measuring Heads ghly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct insertion

More information

Remote Display Unit. Installers Handbook Copyright 2001 AirSense Technology Ltd. LM Remote Display Unit Installers Handbook Issue 1.

Remote Display Unit. Installers Handbook Copyright 2001 AirSense Technology Ltd. LM Remote Display Unit Installers Handbook Issue 1. Remote Display Unit Installers Handbook Copyright 2001 AirSense Technology Ltd AirSense, ClassiFire, FastLearn PipeCAD, SenseNET, Stratos-HSSD and Stratos-Quadra are trademarks. HSSD is a Registered Trademark.

More information

Tuneable White DMX LED Driver

Tuneable White DMX LED Driver Tuneable White DMX LED Driver LDMX-PWM-VW 2016 Digilin Australia. Document Rev : 5. 2-4 Nov ember 2016 Product spe cifications are subject to change without no tice. WAR M COOL NC Tuneable White DMX LED

More information

Absolute encoders multiturn

Absolute encoders multiturn elektronischer electronic multiturn, Multiturn, magnetic magnetisch Sendix M66 / M68 (shaft / hollow shaft) The Sendix M6 with Energy Harvesting Technology is an electronic multiturn encoder in miniature

More information

Product manual. Mylos KNX Shutter actuator 2CSY1104C/S

Product manual. Mylos KNX Shutter actuator 2CSY1104C/S Product manual Mylos KNX Shutter actuator 2CSY1104C/S Contents Contents 1 Technical features... 3 1.1 Technical data... 3 1.2 Connection diagram... 4 2 Commissioning... 5 2.1 Parameters... 5 2.1.1 General...

More information

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol with PROFIBUS-PA procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application 00 II () G FISCO The SINEAX VK 66 is a temperature transducer for use in aumation systems

More information

FL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact

FL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact FL ballasts EL HE PC TC PRO sr 1/2x11 42 W PC PRO compact Product description CELMA Energy Efficiency Index A2 BAT / A2 T Nominal life-time up to 50,000 h (at ta 50 C with a failure rate max. 0.2 % per

More information

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8. TF / TF -Ex Field mounted temperature transmitters, PROFIBUS PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN P R O F I PROCESS FIELD BUS B U S Input Resistance thermometer (,, -wire

More information

Features of Uni-Thermo

Features of Uni-Thermo Pelti ier Device in the 21st Uni-Thermo Century Hi eliability NTENTS Comparison with a Conventional Peltier Device. The Result of Operating Reliability Test Peltier Device Uni-Thermo Quality Chart Peltier

More information

SPECIFICATION SHEET : FHS2-UNV-36L

SPECIFICATION SHEET : FHS2-UNV-36L SPECIFICATION SHEET : FHS2-UNV-36L This Is An Original Product From Fulham Co., Inc Description : Emergency LED Driver For Back-up Lighting This driver will operate constant current LED arrays with a working

More information

Installation Instructions

Installation Instructions PACKAGE CONTENTS ITEM QUANTITY Enthalpy Sensor (Part No. HH57AC078) No. 6B, 3 4-in. long Sheet Metal Screw 2 Blue Wire Assembly (256-in. long with 4-in. quick-connect fitting)* Violet Wire Assembly (256-in.

More information

Flexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB March 2008

Flexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB March 2008 Flexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB41-078 March 2008 FT-19R and FT-19RX FT-19R 3RU with Individual Clear Covers APPLICATION FEATURES The type FT-19R (standard length) and

More information

ISSPRO 3 3/8 Programmable Tachometer High Performance EV Line Part Numbers R5535M, R6535M

ISSPRO 3 3/8 Programmable Tachometer High Performance EV Line Part Numbers R5535M, R6535M General Information: I n c o r p o r a t e d ISSPRO 3 3/8 Programmable Tachometer High Performance EV Line Part Numbers R5535M, R6535M ISSPRO, INC. 2515 N.E. Riverside Way, Portland OR 97211 Telephone:

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for

More information

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components: SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine

More information

Rain Watch TM Set up Manual. IC System with Rain Bird IC CONNECT

Rain Watch TM Set up Manual. IC System with Rain Bird IC CONNECT Rain Watch TM Set up Manual IC System with Rain Bird IC CONNECT December 2018 Table of Contents Required materials to configure Rain Watch TM... 3 Installation... 4 Location... 4 Field Installation...

More information

CDS. high density spring connection

CDS. high density spring connection CDS high density spring connection DENSTY STANDARD 1A CDS DENSTY A A spring connection CDS Series The originality of multipole connectors represents one of the core values of LE, a leading company in this

More information

www. ElectricalPartManuals. com Flexitest Switch Assemblies Type FT-19R and FT-19RX INTL APPLICATION

www. ElectricalPartManuals. com Flexitest Switch Assemblies Type FT-19R and FT-19RX INTL APPLICATION Effective: January 2004 Supersedes, dated June 1998 APPLICATION QUALITY FEATURES Descriptive Bulletin 41-078INTL Flexitest Switch Assemblies Type The type FT-19R (standard length) and FT-19RX (extended

More information

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2... Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed

More information

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for

More information

BMXART0814 analog input module M340-8 inputs - temperature

BMXART0814 analog input module M340-8 inputs - temperature Characteristics analog input module M340-8 inputs - temperature Complementary Analog/Digital conversion Analogue input resolution Input impedance Permitted overload on inputs Common mode rejection Differential

More information

ENSC387: Introduction to Electromechanical Sensors and Actuators LAB 3: USING STRAIN GAUGES TO FIND POISSON S RATIO AND YOUNG S MODULUS

ENSC387: Introduction to Electromechanical Sensors and Actuators LAB 3: USING STRAIN GAUGES TO FIND POISSON S RATIO AND YOUNG S MODULUS ENSC387: Introduction to Electromechanical Sensors and Actuators LAB 3: USING STRAIN GAUGES TO FIND POISSON S RATIO AND YOUNG S MODULUS 1 Introduction... 3 2 Objective... 3 3 Supplies... 3 4 Theory...

More information

OASIS WIRELESS WEATHER STATION

OASIS WIRELESS WEATHER STATION User Manual 3910-B Royal Avenue, Simi Valley, Ca 93063 805-527-4498 RMIS Part No. 500760 TABLE OF CONTENTS INTRODUCTION General Description 3 General Precautions 3 INSTALLATION Base Preparation 6 Tower

More information

Drive electronics pq12

Drive electronics pq12 Drive electronics pq12 Amplifier module with constant current controller for proportional valves Control of one solenoid Easy mounting directly on bearing rails acc. to EN 50022 Standard voltage and current

More information

What You Need to Get Started INSTALLATION GUIDE

What You Need to Get Started INSTALLATION GUIDE INSTALLATION GUIDE SBS-96F SHIELDED BACKSHELL This guide describes how to assemble and install the SBS-96F shielded backshell with low-voltage SCXI modules, VXI-DAQ modules, or low-voltage TBX terminal

More information

P03/3-RS485-WAGO. Weather Station with RS485 Interface. Technical specifications and installation instructions

P03/3-RS485-WAGO. Weather Station with RS485 Interface. Technical specifications and installation instructions EN P03/3-RS485-WAGO Weather Station with RS485 Interface Technical specifications and installation instructions Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone

More information

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -C - Safety section - This Safety section should be read before starting any work on the relay.

More information

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH General information These connectors are designed and produced in conformity with the low-voltage directive (/3/EWG) respectively

More information

KZPb

KZPb ---------------------------------------------------------- ---------------------------------------------------------------------- Electronic constant pressure regulator FUNCTION KZP is an electronic pressure

More information

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, W EXCEL T5

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, W EXCEL T5 F ballasts E PCA EXCE oneall lp Y II, 1 80 W EXCE Product description Processor-controlled ballast with y II inside Highest possible energy class CEMA EEI = A1 BAT 1 oise-free precise control via I or

More information

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar

More information

Features of Uni-Thermo

Features of Uni-Thermo Long-life. High reliability Uni-Thermo Peltier Device in the 1st Century CONTENTS Comparison with a Conventional Peltier Device. The Result of Operating Reliability Test Peltier Device Uni-Thermo Quality

More information

Sensor/actuator cabling PLUSCON field Sensor/actuator boxes M12 distributor with metal thread, heavy-duty

Sensor/actuator cabling PLUSCON field Sensor/actuator boxes M12 distributor with metal thread, heavy-duty Sensor/actuator boxes M distributor with metal thread, heavy-duty Notes: Suitable for SPEEDCON and M standard, see page:. For further technical data, see: www.phoenixcontact.net/catalog With a master cable

More information

5SJ4...-.HG Circuit Breakers to IEC and UL 489

5SJ4...-.HG Circuit Breakers to IEC and UL 489 Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is

More information

Welcome. Functionality and application of RTD Temperature Probes and Thermocouples. Dipl.-Ing. Manfred Schleicher

Welcome. Functionality and application of RTD Temperature Probes and Thermocouples. Dipl.-Ing. Manfred Schleicher Welcome Functionality and application of RTD Temperature Probes and Thermocouples Dipl.-Ing. Manfred Schleicher This presentation informs about the basics of RTD Temperature Probes and thermocouples Functionality

More information

DRS 61: Incremental encoders, number of lines and zero pulse width freely programmable DRS 60: Incremental Encoders with Zero-Pulse-Teach

DRS 61: Incremental encoders, number of lines and zero pulse width freely programmable DRS 60: Incremental Encoders with Zero-Pulse-Teach NEW DRS : Incremental encoders, number of lines and zero pulse width freely programmable DRS : s with Zero-Pulse-Teach Further highlights of this generation of encoders: Simple zero-pulse-teach by pressing

More information

473 Dew Point Hygrometer

473 Dew Point Hygrometer High Performance Chilled Mirror Hygrometer With Cable Mounted Measuring Heads Highly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct

More information