POINTS OF CAUTION BEFORE USE...
|
|
- Branden Stokes
- 5 years ago
- Views:
Transcription
1 INSTRUCTION MANUAL NPN DISCRETE INPUT & NPN TRANSISTOR OUTPUT MODULE, 6 points each (-I/-II, e-con connector) MODEL BEFORE USE... Thank you for choosing M-System. Before use, check the contents of the package you received as outlined below. If you have any problems or questions with the product, please contact M-System s Sales Office or representatives. PACKAGE ILUDES Discrete I/O module... () Surface mounter slider... () MODEL NO. Confirm that the model number described on the product is exactly what you ordered. INSTRUCTION MANUAL This manual describes necessary points of caution when you use this product, including installation, connection and basic maintenance procedures. POINTS OF CAUTION CONFORMITY WITH EC DIRECTIVE The actual installation environments such as panel configurations, connected devices and connected wires may affect the protection level of this unit when it is integrated in a panel system. The user may have to review the CE requirements in regard to the whole system and employ additional protective measures to ensure CE conformity. POWER INPUT RATING & OPERATIONAL RANGE Locate the power input rating marked on the product and confirm its operational range as indicated below V DC rating V ±0%, approx. 7mA REMOVING THE UNIT Before you remove the unit or mount it, turn off the power supply and input signal for safety. ENVIRONMENT Indoor use When heavy dust or metal particles are present in the air, install the unit inside proper housing with sufficient ventilation. Do not install the unit where it is subjected to continuous vibration. Do not apply physical impact to the unit. Environmental temperature must be within 0 to + C ( to F) with relative humidity within 0 to 90% RH in order to ensure adequate life span and operation. WIRING Do not install cables close to noise sources (relay drive cable, high frequency line, etc.). Do not bind these cables together with those in which noises are present. Do not install them in the same duct. AND... The unit is designed to function as soon as power is supplied, however, a warm up for 0 minutes is required for satisfying complete performance described in the data sheet. P. / 8
2 06789ABCDEF 06789ABCDEF COMPONENT IDENTIFICATION FRONT VIEW Status Indicator LED Station Address Setting Rotary SW I/O Connector Discrete I/O Status Indicator LED Power Supply Sensor Exc. Connector PWR ERR RD SD STATION ADD. 0 X0 X X X X X X6 X7 X8 X9 XA XB XC XD XE XF X0 6 7 X8 9 A B C D E F Y0 6 7 SW Y8 9 A B C D E F ON Y0 Y Y Y Y Y Y6 Y7 Y8 Y9 YA YB YC YD YE YF Connector Operating Mode Setting DIP SW (SW) STATUS INDICATOR LED ID COLOR FUTION PWR ERR SD RD Green Red Green Green Turns on when internal power is supplied normally, and off with internal power failure. Turns on with station address setting error, and off with normal station address setting. Turns on when transmitting data, and off when not transmitting data. Turns on when receiving data, and off when not receiving data. DISCRETE I/O STATUS INDICATOR LED LED green indicators show each I/O signal status. ON LED ON OFF LED OFF STATION ADDRESS The left switch determines the upper digit, while the right switch does the lower digit of the station address (hexadecimal number). (Range 60H to 7FH)* (Factory setting 6H) MODE Set either -I or -II, and the data size with SW- and SW-. SW- SW- OFF OFF -II ( byte mode) (*) ON OFF -II (7 byte mode) ON ON -I (7 byte mode) (*) Factory setting Caution! - Since SW- and SW- are unused, be sure to turn them off. POWER SUPPLY, SENSOR EXCITATION Cable connector FMC, / STF, (Phoenix Contact) (included in the package) Applicable wire size 0.. mm ; stripped length 0 mm Recommended solderless terminal AI0, 0YE 0. mm (Phoenix Contact) AI0, 0TQ 0. mm (Phoenix Contact) AI0, 0WH 0. mm (Phoenix Contact) AI0,7 0GY 0.7 mm (Phoenix Contact) A 0.0 mm (Phoenix Contact) A, 0. mm (Phoenix Contact). PWR+. PWR. FE. SNSR.EXC+. SNSR.EXC Power Supply ( V DC) Power Supply (0 V) Functional earth Sensor excitation ( V DC) Sensor excitation (0 V) Station Address Setting (x) Station Address Setting (x6) * As R7KDML is simple I/O, set the station address within the range from 60H to 7FH. Refer to the instruction mannual of the master unit for unselectable addresses, which depending on master unit types. P. / 8
3 TERMINAL ASSIGNMENTS I/O Connection Recommended cable connector 70-( )-000FL (M Company) (The cable connector is not included in the package. Specify wire size instead of ( ); refer to the specifications of the product.) X0 X X X X X X6 X7 X8 X9 XA XB XC XD XE XF Y0 Y Y Y Y Y Y6 Y7 Y8 Y9 YA YB YC YD YE YF No. ID FUTION No. ID FUTION No. ID FUTION No. ID FUTION +V V DC +V V DC +V V DC +V V DC X0 Unused Unused Unused Unused X8 Y0 Y8 GND 0V GND 0V Unused Unused X0 Input 0 X8 Input 8 Y0 Output 0 Y8 Output 8 +V V DC +V V DC +V V DC +V V DC X Unused Unused Unused Unused X9 Y Y9 GND 0V GND 0V Unused Unused X Input X9 Input 9 Y Output Y9 Output 9 +V V DC +V V DC +V V DC +V V DC X Unused Unused Unused Unused XA Y YA GND 0V GND 0V Unused Unused X Input XA Input 0 Y Output YA Output 0 +V V DC +V V DC +V V DC +V V DC X Unused Unused Unused Unused XB Y YB GND 0V GND 0V Unused Unused X Input XB Input Y Output YB Output +V V DC +V V DC +V V DC +V V DC X Unused Unused Unused Unused XC Y YC GND 0V GND 0V Unused Unused X Input XC Input Y Output YC Output +V V DC +V V DC +V V DC +V V DC X Unused Unused Unused Unused XD Y YD GND 0V GND 0V Unused Unused X Input XD Input Y Output YD Output +V V DC +V V DC +V V DC +V V DC X6 Unused Unused Unused Unused XE Y6 YE GND 0V GND 0V Unused Unused X6 Input 6 XE Input Y6 Output 6 YE Output +V V DC +V V DC +V V DC +V V DC X7 Unused Unused Unused Unused XF Y7 YF GND 0V GND 0V Unused Unused X7 Input 7 XF Input Y7 Output 7 YF Output CONNECTION Master Slave * * terminator SRD+ SRD+ SRD+ SRD+ SRD+ SRD+ terminator Cable Cable * Terminator Be sure to connect the terminating resistors to the unit at both ends of transmission line. Use the terminating resistor dedicated for Model JEPMC-W60, Yaskawa Controls Co., Ltd. Certain types of Master units may have incorporated terminating resistors. Consult the instruction manual for the Master. Slave P. / 8
4 MOUNTING INSTRUCTIONS DIN RAIL MOUNTING Mounting ) Set the upper hook at the rear side of the unit on the DIN rail. ) Push in the lower. SURFACE MOUNTING ) Insert the two DIN rail mounter sliders until it clicks once, as shown below. ) Mount the unit with M screws referring to the EXTER- NAL DIMENSIONS. (Torque. N m) Dismounting ) Push down the DIN rail mounter slider with the tip of a minus screwdriver. ) Pull the lower of the unit. ) Remove the upper hook of the unit from the DIN rail. MOUNTING REQUIREMENTS unit mm (inch) M 0 (8.66) P. / 8
5 TERMINAL CONNECTIONS Connect the unit as in the diagram below. EXTERNAL DIMENSIONS mm (inch) (9.) 0 (8.66) 0 (8.7) (.6) (.0) DIN RAIL mm wide. (.) 0 (.97) (.0) -. dia. deep ( dia. 0.6 deep) [ (.6)] CONNECTION DIAGRAM CN CN Connector Connector +V GND X0 +V GND XF +V Y0 +V YF PWR+ PWR FE SNSR.EXC+ SNSR.EXC + + Detecting Circuit Detecting Circuit OUTPUT Y0 OUTPUT YF POWER SUPPLY (IN) SENSOR EXC. (IN) INPUT X0 INPUT XF -Wire Sensor +V GND Xn Detecting Circuit PWR+ PWR FE SNSR.EXC+ SNSR.EXC POWER SUPPLY (OUT) SENSOR EXC. (OUT) Note In order to improve EMC performance, bond the FE terminal to the ground. Caution FE terminal is NOT a protective conductor terminal. P. / 8
6 COMMUNICATION -I Baud rate Mbps Transmission distance 0 m max. Distance between stations 0 cm min. Transmission media cable (Model JEPMC-W600-x-E, Yaskawa Controls Co., Ltd.) Max. number of slaves (The maximum number of slaves might change depending on the master unit. Refer to the manual of the master unit.) Transmission cycle msec. (fixed) Data length 7 byte -II Baud rate 0 Mbps Transmission distance 0 m max. Distance between stations 0 cm min. Transmission media cable (Model JEPMC-W600-x-E, Yaskawa Controls Co., Ltd.) Max. number of slaves 0 (The maximum number of slaves might change depending on the master unit. Refer to the manual of the master unit.) Transmission cycle 0.msec., 0. msec., msec.,. msec., msec.,. msec., msec., msec., 8 msec. Data length 7 byte / byte selectable (Must choose identical data size for all stations within the network) P. 6 / 8
7 RELATED COMMANDS R7KDML (Simple I/O) communicates with I/O service with no processer, therfore it uses a connectionless communication protocol. There is no application layer either; the R7KDML interchanges I/O data via data link layer. DATA LINK LAYER COMMAND DESCRIPTIONS The following tables explain the two Commands supported by the R7KDML. MDS Command (0H) Data Format BYTE COMMAND RESPONSE REMARKS 0 MDS (0H) S(0) (90H) Message Data Search (MDS) Command Read the ID from slave station(s) S(0) Response to MDS ID All Byte 7 through are always 0 in the -byte mode. These bytes are unavailable for -I and II in the 7-byte mode. CDRW Command (0H) Data Format BYTE COMMAND RESPONSE REMARKS 0 CDRW (0H) ACK (0H) Cyclic Data Read/Write (CDRW) Command Link transmission Acknowledge (ACK) Positive response to CDRW Out Data Lowest In Data Lowest Order of data Little Endian Out Data Highest In Data Highest 7 Out Data Highest In Data Highest Byte7through are unavailable for -I and -II in the 7-byte mode. (Only available for -II in the -byte mode) P. 7 / 8
8 I/O DATA DESCRIPTIONS 7-BYTE MODE 6 points input data Byte Bit7 Bit6 Bit Bit Bit Bit Bit Bit0 In7 In6 In In In In In In0 In In In In In In0 In9 In BYTE MODE 6 points input data Byte Bit7 Bit6 Bit Bit Bit Bit Bit Bit0 In7 In6 In In In In In In0 In In In In In In0 In9 In points output data Byte Bit7 Bit6 Bit Bit Bit Bit Bit Bit Out7 Out6 Out Out Out Out Out Out0 6 Out Out Out Out Out Out0 Out9 Out8 6 points output data Byte Bit7 Bit6 Bit Bit Bit Bit Bit Bit Out7 Out6 Out Out Out Out Out Out0 Out Out Out Out Out Out0 Out9 Out8 0 OFF, ON At the loss of communication, output is hold. (last data correctly received is hold) P. 8 / 8
BEFORE USE... POINTS OF CAUTION COMPONENT IDENTIFICATION INSTRUCTION MANUAL MODEL R7K4DH-1-DAC32D R7K4DH-1-DAC32D
INSTRUCTION MANUAL PNP DISCRETE INPUT & PNP TRANSISTOR OUTPUT MODULE, 6 points each (High-speed Link System, e-con connector) R7KDH--DACD MODEL R7KDH--DACD BEFORE USE... Thank you for choosing M-System.
More informationMODEL: R7K4FML3. Remote I/O R7K4F Series. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.)
Remote I/O R7KF Series I/O MODULE (-III) POWER INPUT DC power R: V DC (Operational voltage range: ±0 %; ripple 0 %p-p max.) 0 (8.7). (.) 7(.8) mm (inch) [] OPTIONS (multiple selections) Output data read
More informationMODEL: R7FN. Remote I/O R7 Series FLEX NETWORK I/O MODULE
MODEL: RFN Remote I/O R Series FLEX NETWORK I/O MODULE /C0: Rubber coating EX-FACTORY SETTING /SET: Preset according to the Ordering Information Sheet (No. ESU-0-x) ORDERING INFORMATION Basic module: RFN-[]-R[]
More informationMODEL: R7M. Remote I/O R7 Series MODBUS I/O MODULE
MODEL: RM Remote I/O R Series MODBUS I/O MODULE RS: RTD input, points MS: Potentiometer input, points (Option /UL Not selectable) CTE: AC current input, points, Clamp-on current sensor CLSE use (Option
More informationPHOENIX CONTACT - 04/2016. Features
Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.
More information32 Input AC Block I/O Module
Input AC Module Cat. No. 79-A0 Series B Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air to flow through
More information16 Input AC Block I/O Module
6 Input AC Module Cat. No. 79-6A0 Series B Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air flow through
More informationISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER
ISOCON-6 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting
More informationSafety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.
Safety Precautions Observe the following notices to ensure personal safety or to prevent accidents. To ensure that you use this product correctly, read this User s Manual thoroughly before use. Make sure
More informationAcceleration/Velocity/Displacement VIBRATION METER
Acceleration/Velocity/Displacement VIBRATION METER Model : VB-8220 Your purchase of this VIBRATION METER marks a step forward for you into the field of precision measurement. Although this METER is a complex
More informationISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER
ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER CAUTION: This equipment is designed for connection to mains voltages and must be used in accordance with this guide. If it is not, the safety protection
More informationtechnical bulletin Installation Instructions: Wall-Mount Dewpoint Probe ( )
Installation Instructions: Wall-Mount Dewpoint Probe (809-2011) The HMW90 Wall-Mount Dewpoint Probe (P/N 809-2011) HMW90 measures dewpoint for indoor applications such as anti-sweat heater control and
More informationFLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:
abc instruments international FLT5A Thermometer Land Instruments International Dronfield, S18 1DJ England Telephone: (1246) 417691 Facsimile: (1246) 41585 Email: infrared.sales@landinst.com Internet: www.landinst.com
More informationDS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.
DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link
More informationWeather Station P03/3-Modbus-GPS for Modbus
Weather Station P03/3-Modbus-GPS for Modbus Technical specifications and installation instructions Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D-75391 Gechingen Germany Phone: +49
More informationSC125MS. Data Sheet and Instruction Manual. ! Warning! Salem Controls Inc. Stepper Motor Driver. Last Updated 12/14/2004
SC125MS Stepper Motor Driver Salem Controls Inc. Last Updated 12/14/2004! Warning! Stepper motors and drivers use high current and voltages capable of causing severe injury. Do not operate this product
More informationMeteorological Station P03/3-RS485-WAGO
Meteorological Station P03/3-RS485-WAGO Technical data and notes for installation Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D-75391 Gechingen Germany Phone: +49 (0) 70 56/93 97-0
More informationOperating Instructions for Digital Manometer. Model: MAN-SD
Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5
More informationThe Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:
The basic PC software is supplied free with the recorder. There is an additional charge for the extensive Data Acquisition Software supplied with communication of RS-232/422/485 or Ethernet. The Ordering
More informationProximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C
ASH & ALAIN INDIA PVT LTD S-00, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-000(India) Tel : 0-797575 Fax : 0-79757 E-mail : sales@ashalain.com Proximity Ideal for High Temperatures and Cleaning
More informationLatest generation testo air velocity & IAQ probes with cable handle. Instruction manual
Latest generation testo air velocity & IAQ probes with cable handle Instruction manual Contents Contents 1 About this document... 5 2 Safety and disposal... 5 3 System description... 6 4 Description of
More informationOPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820
Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820 Your purchase of this PEN VIBRATION METER marks a step forward for you into the field of precision measurement.
More informationAcceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202
Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202 Your purchase of this VIBRATION METER marks a step forward for you into the field of precision measurement. Although this METER is
More informationInstallation Instructions: ICON Anti-Condensate Controller
TECHNICAL BULLETIN Installation Instructions: ICON Anti-Condensate Controller System Overview The ICON Anti-Condensate Controller System (pat. pend.) is a stand-alone controller for antisweat heaters in
More informationInstallation guide 862 MIT / MIR
Installation guide 862 MIT / MIR in combination with: 864 MTT or 863 MRT or (dual) spot element November 2005 Part no. 4416.232_Rev3 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100
More informationOPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820
Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820 Your purchase of this PEN VIBRATION METER marks a step forward for you into the field of precision measurement.
More informationLinear measuring technology
Their extremely robust construction, their high IP69k protection level and their wide temperature range make these new draw wire encoders particularly reliable and durable. Their flexibility and adaptability
More informationS Sapling INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS. advanced time and control systems
INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS Time base: 60 Hz (3-wire system) Quartz (2-wire system) Power input: 85 135 VAC / 60 Hz 7 28 VAC / 60 Hz Current consumption:
More informationED 701 General Industry Pressure Transmitter
ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationFATEK. FBs-1HLC. Precision Load Cell Module. Operation manual V1.1 06/07/2017 FATEK AUTOMATION CORP.
FATEK FBs-1HLC Precision Load Cell Module Operation manual V1.1 06/07/2017 FATEK AUTOMATION CORP. 1 Contents Chapter 1 1HLC module introduction... 3 1.1 Module specification... 3 1.2 Module appearance
More informationBMXART0814 analog input module M340-8 inputs - temperature
Product data sheet Characteristics BMXART0814 analog input module M340-8 inputs - temperature Main Range of product Product or component type Electrical connection Input output isolation Input level Analogue
More informationE2T0 DVP
29-5-26 5116868-E2T DVP-11363-1 ENGLISH Thank you for choosing Delta s DVP series PLC. DVP4TC-E2 temperature measurement module receives 4 points of external thermocouple temperature sensors (J-type, K-type,
More informationNOVALYNX CORPORATION MODEL 110-WS-16BP BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL
NOVALYNX CORPORATION MODEL 110-WS-16BP BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL REVISION DATE: OCT 2005 Receiving and Unpacking Carefully unpack all components and compare to the packing list. Notify
More informationVIBRATION METER Acceleration & Velocity Model : VB-8201HA
VIBRATION METER Acceleration & Velocity Model : VB-8201HA TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS...2 3. FRONT PANEL DESCRIPTION...4 3-1 Display...4 3-2 BNC socket of meter...4 3-3 RMS/PEAK
More informationWeather Station P03/3-RS485 with RS485 Interface
Weather Station P03/3-RS485 with RS485 Interface Technical data and notes for installation Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D-75391 Gechingen Germany Phone: +49 (0) 70
More informationDigital display Pressure range ON/OFF output Linear output Model No Positive pressure 0 to 98 kpa (0 to 1 kgf/cm 2 ) NPN open collector o 1 to o5
Pressure Sensor E8CC with Built-in Microcomputer and Digital Display and New E8CB General-purpose Model Withstands a of 490 kpa (5 kgf/cm 2 ) and highly reliable. Incorporates a two-turn adjuster ensuring
More informationDifferential Pressure Sensor
Differential Pressure Sensor MDP200 Series Features Pressure range up to ±500Pa with high accuracy of ±3.0% m.v. Pressure based on thermal micro-flow measurement Outstanding hysteresis and repeatability
More informationD5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder
with incremental encoder Draw wire encoder A40 Traverse speed max. 0.8 m/s The draw wire system A40 with incremental encoder excels with its compact construction. RoHS Compact and simple Measuring length
More informationPTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30
eries Features Best pressure transmission solution for small and middle sized project such as indoor heating and air conditioning, water and sewer, or incinerator, etc. Improves noise resistance and minimize
More informationSecured Series Front End Reader Installation Instructions Proximity Reader (ProxPro, ProxPro w/keypad, MiniPro, Thinline II)
Secured Series Front End Reader Installation Instructions Proximity Reader (ProxPro, ProxPro w/keypad, MiniPro, Thinline II) Installation Procedure: Step 1: Check the Packing List Step 2: Mount the Proximity
More informationMultichannel Brake Infrared Temperature Sensor - Datasheet
The Izze-Racing Multichannel Brake Infrared Temperature Sensor is specifically designed to measure the highly transient surface temperature of a brake rotor at multiple points, making it possible to acquire
More informationOPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000
3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER Model : TM-2000 Your purchase of this THERMOMETER marks a step forward for you into the field of precision measurement. Although this THERMOMETER is a
More informationOPERATING MANUAL. EIB-Kombisensor AS 315 N
EIB-Kombisensor AS 315 N OPERATING MANUAL EIB-Kombisensor AS 315 N 1 Contents Page 3 1. Description 4 1.1 Automated Operations 1.1.1 Sun System 1.1.2 Half-Light System 5 1.1.3 Wind System 1.1.4 Rain System
More informationWeather Station P03/3-RS485-GPS with RS485 Interface
Weather Station P03/3-RS485-GPS with RS485 Interface Technical data and notes for installation Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D-75391 Gechingen Germany Phone: +49 (0)
More informationE6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders
Multi-turn High-precision Encoder Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders Reset function for easy origin alignment when built-into equipment. Multi-turn
More informationMinute Impulse Clock Controller I01DN
99b-mi USER S MANUAL Minute Impulse Clock Controller Mon Jun 01, 2009 12:00:00 PM DST HOLD ENTER KEY TO BEGIN CANCEL HR I01DN 97 West Street Medfield, MA 02052 U.S.A. (508) 359-4396 Pg. 2 of 20 TABLE OF
More informationLamp and Control Panel (Lamp Panel)
www.reinhausen.com Lamp and Control Panel (Lamp Panel) Operating Instructions BA 47/0 EN NOTE! Changes may have been made to a product after going to press with this documentation. We expressly reserve
More informationINSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: (50 ), (54 ), or (60 ) Application: All Terrain Vehicles
INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: 78950 (50 ), 78954 (54 ), or 78960 (60 ) Application: All Terrain Vehicles Your safety, and the safety of others, is very important. To help you make
More informationNo /06e. Technical Manual Multistage-Temperature-/Differential Controller TAR x700
Technical Manual Multistage-Temperature-/Differential Controller x700 Software Version 0078 o. 5303-0/06e 700 3700 5700 9700 3700 5700 9700 l Suitable as : Multistage Controller or Differential Controller
More informationE8EB-N0C2B E8EB-N0B2B
Slim Sensor CSM DS_E 1 Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree
More informationPressure Transmitter ED 701
Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation
More informationxlogic SuperRelay is a compact and expandable CPU replacing mini PLCs, multiple timers, relays and counters.
SuperRelay S U P E R R E L A Y, T H E P E R F E C T A L T E R N A T I V E T O L O W C O S T P L C s A N D B A S I C R E L A Y S I N T H I S B R O C H U R E : ELC 18 Standard Models ELC 18 Economy Models
More information14.05 (356,9) (344,2) 2.60 (66,0) 3.00 (76,2) STATUS LED
RACKS Channel FEATURES For use with Style Controllers Available for Standard, Miniature, G and OpenLine Modules Panel and DIN Rail Mount Versions UL, CSA Certified CHANNEL RACK: Standard Part No. 0RCK
More informationSZ7001. Wireless ZIGBEE tipping bucket rain sensor. Product Overview. Dimensions. parameter. September, 2016 Rev.
SZ7001 Wireless ZIGBEE tipping bucket rain sensor http:// www.sonbus.com Product Overview Tipping bucket rain sensor for measuring the nature of rainfall, while rainfall is converted to digital information
More informationSPECIFICATION SHEET : FHS2-UNV-36L
SPECIFICATION SHEET : FHS2-UNV-36L This Is An Original Product From Fulham Co., Inc Description : For Back-up Lighting This driver will operate constant current LED arrays with a working voltage between
More informationMULTI-OUTPUT PROGRAMMABLE CONTROLLERS MODELS UMX-4 & UMX-8
February 1994 20/20 Interface Products MULTI-OUTPUT PROGRAMMABLE CONTROLLERS MODELS & DESCRIPTION The is a Multi-output Programmable Controller which expands the input or output capability of building
More informationSeries CCT-58S Multi-Throw DC 18 GHz, SP7T & SP8T Normally Open Coaxial Switch
PART NUMBER CCT-58S DESCRIPTION Commercial Normally Open Multi-throw, DC-18 GHz The CCT-58S/CT-58S is an internally terminated, broadband, multi-throw, electromechanical coaxial switch designed to switch
More informationThermal-Magnetic Circuit Breaker 2210-T2...
Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring
More informationMODBUS Protocol for CS141 network card families
Last update: 20/09/208 MODBUS Protocol for CS4 network card families Summary. MODBUS PROTOCOL... 2.. MODBUS COMMUNICATION PARAMETERS... 2.2. AVAILABLE MODBUS FUNCTION CODES... 2.3. EXCEPTION CODES... 3
More informationXD1-L Cable Differential Protection Relay
XD1-L Cable Differential Protection Relay Manual XD1-L (Revision B) Woodward Manual XD1-L GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information
More informationMAGPOWR TENSION CONTROL DLCA NET-SLIM. User Manual. Digital Load Cell Amplifier MI 850A358 1 A
MAGPOWR TENSION CONTROL DLCA NET-SLIM User Manual EN Digital Load Cell Amplifier MI 850A358 1 A CONTENTS 1.0 INTRODUCTION 4 1.1 About these operating instructions... 4 1.2 Product overview... 5 1.2.1 Additional
More information473 Dew Point Hygrometer
gh Performance Chilled Hygrometer With Cable Mounted Measuring Heads ghly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct insertion
More informationRemote Display Unit. Installers Handbook Copyright 2001 AirSense Technology Ltd. LM Remote Display Unit Installers Handbook Issue 1.
Remote Display Unit Installers Handbook Copyright 2001 AirSense Technology Ltd AirSense, ClassiFire, FastLearn PipeCAD, SenseNET, Stratos-HSSD and Stratos-Quadra are trademarks. HSSD is a Registered Trademark.
More informationTuneable White DMX LED Driver
Tuneable White DMX LED Driver LDMX-PWM-VW 2016 Digilin Australia. Document Rev : 5. 2-4 Nov ember 2016 Product spe cifications are subject to change without no tice. WAR M COOL NC Tuneable White DMX LED
More informationAbsolute encoders multiturn
elektronischer electronic multiturn, Multiturn, magnetic magnetisch Sendix M66 / M68 (shaft / hollow shaft) The Sendix M6 with Energy Harvesting Technology is an electronic multiturn encoder in miniature
More informationProduct manual. Mylos KNX Shutter actuator 2CSY1104C/S
Product manual Mylos KNX Shutter actuator 2CSY1104C/S Contents Contents 1 Technical features... 3 1.1 Technical data... 3 1.2 Connection diagram... 4 2 Commissioning... 5 2.1 Parameters... 5 2.1.1 General...
More informationSINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol
with PROFIBUS-PA procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application 00 II () G FISCO The SINEAX VK 66 is a temperature transducer for use in aumation systems
More informationFL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact
FL ballasts EL HE PC TC PRO sr 1/2x11 42 W PC PRO compact Product description CELMA Energy Efficiency Index A2 BAT / A2 T Nominal life-time up to 50,000 h (at ta 50 C with a failure rate max. 0.2 % per
More informationTF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.
TF / TF -Ex Field mounted temperature transmitters, PROFIBUS PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN P R O F I PROCESS FIELD BUS B U S Input Resistance thermometer (,, -wire
More informationFeatures of Uni-Thermo
Pelti ier Device in the 21st Uni-Thermo Century Hi eliability NTENTS Comparison with a Conventional Peltier Device. The Result of Operating Reliability Test Peltier Device Uni-Thermo Quality Chart Peltier
More informationSPECIFICATION SHEET : FHS2-UNV-36L
SPECIFICATION SHEET : FHS2-UNV-36L This Is An Original Product From Fulham Co., Inc Description : Emergency LED Driver For Back-up Lighting This driver will operate constant current LED arrays with a working
More informationInstallation Instructions
PACKAGE CONTENTS ITEM QUANTITY Enthalpy Sensor (Part No. HH57AC078) No. 6B, 3 4-in. long Sheet Metal Screw 2 Blue Wire Assembly (256-in. long with 4-in. quick-connect fitting)* Violet Wire Assembly (256-in.
More informationFlexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB March 2008
Flexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB41-078 March 2008 FT-19R and FT-19RX FT-19R 3RU with Individual Clear Covers APPLICATION FEATURES The type FT-19R (standard length) and
More informationISSPRO 3 3/8 Programmable Tachometer High Performance EV Line Part Numbers R5535M, R6535M
General Information: I n c o r p o r a t e d ISSPRO 3 3/8 Programmable Tachometer High Performance EV Line Part Numbers R5535M, R6535M ISSPRO, INC. 2515 N.E. Riverside Way, Portland OR 97211 Telephone:
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for
More informationSECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:
SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine
More informationRain Watch TM Set up Manual. IC System with Rain Bird IC CONNECT
Rain Watch TM Set up Manual IC System with Rain Bird IC CONNECT December 2018 Table of Contents Required materials to configure Rain Watch TM... 3 Installation... 4 Location... 4 Field Installation...
More informationCDS. high density spring connection
CDS high density spring connection DENSTY STANDARD 1A CDS DENSTY A A spring connection CDS Series The originality of multipole connectors represents one of the core values of LE, a leading company in this
More informationwww. ElectricalPartManuals. com Flexitest Switch Assemblies Type FT-19R and FT-19RX INTL APPLICATION
Effective: January 2004 Supersedes, dated June 1998 APPLICATION QUALITY FEATURES Descriptive Bulletin 41-078INTL Flexitest Switch Assemblies Type The type FT-19R (standard length) and FT-19RX (extended
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationBMXART0814 analog input module M340-8 inputs - temperature
Characteristics analog input module M340-8 inputs - temperature Complementary Analog/Digital conversion Analogue input resolution Input impedance Permitted overload on inputs Common mode rejection Differential
More informationENSC387: Introduction to Electromechanical Sensors and Actuators LAB 3: USING STRAIN GAUGES TO FIND POISSON S RATIO AND YOUNG S MODULUS
ENSC387: Introduction to Electromechanical Sensors and Actuators LAB 3: USING STRAIN GAUGES TO FIND POISSON S RATIO AND YOUNG S MODULUS 1 Introduction... 3 2 Objective... 3 3 Supplies... 3 4 Theory...
More informationOASIS WIRELESS WEATHER STATION
User Manual 3910-B Royal Avenue, Simi Valley, Ca 93063 805-527-4498 RMIS Part No. 500760 TABLE OF CONTENTS INTRODUCTION General Description 3 General Precautions 3 INSTALLATION Base Preparation 6 Tower
More informationDrive electronics pq12
Drive electronics pq12 Amplifier module with constant current controller for proportional valves Control of one solenoid Easy mounting directly on bearing rails acc. to EN 50022 Standard voltage and current
More informationWhat You Need to Get Started INSTALLATION GUIDE
INSTALLATION GUIDE SBS-96F SHIELDED BACKSHELL This guide describes how to assemble and install the SBS-96F shielded backshell with low-voltage SCXI modules, VXI-DAQ modules, or low-voltage TBX terminal
More informationP03/3-RS485-WAGO. Weather Station with RS485 Interface. Technical specifications and installation instructions
EN P03/3-RS485-WAGO Weather Station with RS485 Interface Technical specifications and installation instructions Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone
More informationRequest Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.
Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -C - Safety section - This Safety section should be read before starting any work on the relay.
More informationAmphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH
Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH General information These connectors are designed and produced in conformity with the low-voltage directive (/3/EWG) respectively
More informationKZPb
---------------------------------------------------------- ---------------------------------------------------------------------- Electronic constant pressure regulator FUNCTION KZP is an electronic pressure
More informationFL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, W EXCEL T5
F ballasts E PCA EXCE oneall lp Y II, 1 80 W EXCE Product description Processor-controlled ballast with y II inside Highest possible energy class CEMA EEI = A1 BAT 1 oise-free precise control via I or
More informationDS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm
Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar
More informationFeatures of Uni-Thermo
Long-life. High reliability Uni-Thermo Peltier Device in the 1st Century CONTENTS Comparison with a Conventional Peltier Device. The Result of Operating Reliability Test Peltier Device Uni-Thermo Quality
More informationSensor/actuator cabling PLUSCON field Sensor/actuator boxes M12 distributor with metal thread, heavy-duty
Sensor/actuator boxes M distributor with metal thread, heavy-duty Notes: Suitable for SPEEDCON and M standard, see page:. For further technical data, see: www.phoenixcontact.net/catalog With a master cable
More information5SJ4...-.HG Circuit Breakers to IEC and UL 489
Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is
More informationWelcome. Functionality and application of RTD Temperature Probes and Thermocouples. Dipl.-Ing. Manfred Schleicher
Welcome Functionality and application of RTD Temperature Probes and Thermocouples Dipl.-Ing. Manfred Schleicher This presentation informs about the basics of RTD Temperature Probes and thermocouples Functionality
More informationDRS 61: Incremental encoders, number of lines and zero pulse width freely programmable DRS 60: Incremental Encoders with Zero-Pulse-Teach
NEW DRS : Incremental encoders, number of lines and zero pulse width freely programmable DRS : s with Zero-Pulse-Teach Further highlights of this generation of encoders: Simple zero-pulse-teach by pressing
More information473 Dew Point Hygrometer
High Performance Chilled Mirror Hygrometer With Cable Mounted Measuring Heads Highly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct
More information