Product manual. Mylos KNX Shutter actuator 2CSY1104C/S
|
|
- Justin Young
- 6 years ago
- Views:
Transcription
1 Product manual Mylos KNX Shutter actuator 2CSY1104C/S
2 Contents Contents 1 Technical features Technical data Connection diagram Commissioning Parameters General Actuator Status Scenes Position Operation of communication objects Table of 8 bit scene telegram codes Contents MYLOS Building Automation
3 Technical features 1 Technical features The shutter actuator is a flash-mounted device for the ABB's Mylos Building Automation system, used for the control of a drive for shutters or blinds with the possibility of ascent, descent and louvre adjustment. On the rear side it has connecting terminals for ascent and descent commands of a motor operated shutter. From the parameters it is possible to choose the standby time to be applied to every change of direction. 1.1 Technical data Power supply Operating voltage VDC over the bus Absorbed power EIB / KNX < 12 ma Nominal output values Number of Up/DOWN outputs 1 exchange contact UP and DOWN are interlocked Rated voltage U n 230/440 VAC (50/60Hz) Rated current I n (per output) 8A Connections EIB / KNX Connection terminal Bus mm ø, unipole Load circuit 1 screw terminal for phase connection, 2 screw terminals for UP and DOWN Connection cable cross section 0,2.2,5 mm 2 braid 0,2.4 mm 2 unipole Tightening torque Max. 0.5 Nm Control and display elements red LED and EIB / KNX button To set the physical address EIB / KNX EIB / KNX voltage SELV 24 VDC (safety extra low voltage) Ambient temperature Use -5 C + 45 C Storage -25 C + 55 C Transport -25 C + 70 C Design Dimensions (H x W x D) in mm 17 x W x 15 Width W in mm 17 Mounting width in mm 7 Mounting depth in mm 5 Case, colour Plastic container, white or black CE marking acc. to EMC and Low-Voltage Directives Device type Application program Maximum number of communication objects Maximum number of group addresses Maximum number of associations 2CSYK1204 Shutter 1c/ MYLOS Building Automation Technical features 3
4 Technical features Supplied state The device is supplied with the physical address The application program is preloaded. It is therefore only necessary to load group addresses and parameters during commissioning. However, the complete application program can be reloaded if required. A longer downtime may result if the application program is changed or after a discharge. Assignment of the physical address The assignment and programming of the physical address is carried out in the ETS. The device features a Programming button for assignment of the physical device address. The red Programming LED lights up, after the button has been pushed. It switches off, as soon as the ETS has assigned the physical address or the Programming button is pressed again. Cleaning If devices become dirty, they can be cleaned using a dry cloth or a cloth dampened with a soapy solution. Corrosive agents or solutions should never be used. Download behaviour Depending on the PC, which is used, the progress bar for the download may take up to one and a half minutes, before it appears, due to the complexity of the device. Maintenance The device is maintenance-free. No repairs should be carried out by unauthorised personnel if damage occurs, e. g. during transport and/or storage. 1.2 Connection diagram N L M DOWN COMMON UP + 4 Technical features MYLOS Building Automation
5 Commissioning 2 Commissioning The main functions of the shutter actuator are described in this section. The shutter actuator parametrisation is performed via the Engineering Tool ETS Software application program. For the parametrisation you need a pc desktop or a laptop with ETS and connection to the KNX system (obtainable for example by means of RS232, USB or IP Interface). 2.1 Parameters General Operating mode It is possible to define the device operation mode using this parameter, even if the parameters and communication objects for the two operating modes are very similar. Position for bus voltage interruption The parameter allows you to define the device behaviour upon voltage failure. In particular, for the "No reaction" case the output contacts will remain in their position, whereas in the "Stop" case the shutter/blind will stop immediately. Position upon bus voltage restoration Similarly to the previous parameter, this parameter manages the device output contacts upon voltage restoration. 8 bit scene If it is set on Enable both the Scene communication object and the Scenes parameter window will appear. MYLOS Building Automation Commissioning 5
6 Commissioning 2.2 Actuator Stroke duration [0 6000] sec Parameter used to set the stroke duration in seconds. Louvre adjustment duration [ ] msec (only if the operating mode set by parameters is Blind) The parameter determines louvre adjustment duration. Pause in the change of direction msec Pause between two changes of direction Maximum number of louvre adjustments [1 60] msec (only if the operating mode set by parameters is Blind) To set the maximum number of louvre adjustment. Start-up delay [0 255] msec To set the delay upon start-up of any device movement. Switch-off delay [0 255] msec To set the delay at the end of any device movement. Switch the voltage-free outputs after This parameter allows the device to actually reach the (upper or lower) limit switch position. At the limit switch duration a further movement command in the same direction will cause: no reaction for "Limit switch reaching, no exceeding"; a stroke equal to 2% of the stroke duration for "Limit switch, 2% exceeding"; a stroke equal to 5% of the stroke duration for "Limit switch, 5% exceeding"; a stroke equal to 10% of the stroke duration for "Limit switch, 10% exceeding"; a stroke equal to 20% of the stroke duration for "Limit switch, 20% exceeding"; a stroke equal to 110% of the stroke duration for "Stroke total time, 10% exceeding"; 6 Commissioning MYLOS Building Automation
7 Commissioning 2.3 Status Send position [0 255] If Yes the Position status and Louvre status communication objects will appear (the last one only in case of BIlnd operation). Send the position after reaching the limit switch If Yes the Upper limit switch and Lower limit switch will be displayed. MYLOS Building Automation Commissioning 7
8 Commissioning 2.4 Scenes Association 1 Association 10 The parameters allow you to determine which scene group the device belongs to. It is possible to select up to 10 associations and for each association you can select up to 64 scenes. 8 Commissioning MYLOS Building Automation
9 Commissioning 2.5 Position Recall position [0 255] If it is set on Enable the Recall position communication objects will appear. Objects for "Storing position" If it is set on Enable the Store position 1 or 2 and Store position 3 or 4 communication objects will appear. Objects for "Recalling position" If it is set on Enable the Recall position 1 or 2 and Recall position 3 or 4 communication objects will appear. MYLOS Building Automation Commissioning 9
10 Operation of communication objects 3 Operation of communication objects For the "Blind" operating mode: No. Function Object name Type of datum Flags 0 Blind up-down Output 1 bit DPT Up Down C, W For the "Shutter" operating mode: 0 Blind up-down Output 1 bit DPT Up Down C, W If a telegram with the value 0 is received at this communication object, the shutter/blind is raised. If a telegram with the value 1 is received, the shutter/blind is lowered. The output contact reverts to the neutral position once the total travel time for UP/DOWN movement has elapsed. UP 1 : DOWN For the "Blind" operating mode: 1 Louvres/Stop up-down Exit 1 bit DPT Up Down C, W For the "Shutter" operating mode: 1 Stop up-down Output 2 bit (EIS 8) DPT C, W If the shutter/blind is in motion, the movement is stopped on receipt of a telegram at this communication object, regardless of whether a 0 or a 1 has been received. Blinds operating mode: If the shutter is idle, it is raised ( 0 ) or lowered ( 1 ) for the duration of the louvre adjustment and then stopped on receipt of a telegram at this communication object. Shutter operating mode: If the blind is idle, no action is carried out on receipt of a telegram at this communication object. Stop/louvre adj. UP 1 : Stop/louvre adj. DOWN 2 Recall position Exit 1 Byte DPT Percent U8 C, W 10 Operation of communication objects MYLOS Building Automation
11 Operation of communication objects If a telegram is received at this communication object, the shutter/blind moves to the corresponding position for the received value. After reaching the target position, the louvres are positioned as before. Only if during the shutter/blind movement a telegram was received on the communication object Move louvres 0 255, the louvres will be positioned accordingly. Top... : Intermediate position 255 : Bottom 3 Scene Output 1 Byte DPT Scene Control Output can be integrated into up to ten scenes with this communication object. A telegram is received which contains the number of the scene that is addressed together with the information about whether the shutter/blind is moved to the last saved position or whether the current position should be stored as the new preset value. The stored scene values are retained in the event of a bus voltage failure and if only the parameters are downloaded during programming. If the complete application is downloaded again during programming, the scene value is reset to the position right at the top. Telegram code: MXNNNNNN NNNNNN: : Scene number M: Recall scene 1 : Store scene 4 Position status Output 1 Byte DPT Percent U8 C, W C, R, T The Shutter Actuator sends the current position of the shutter/blind to this communication object. The current position is sent approx. 5 seconds after the completion of a movement. If a new movement is started in the meantime, the current position is only sent once the last action has been completed. Top... : Intermediate position 255 : Bottom For the "Shutter" operating mode: 5 Louvres status Exit 1 Byte DPT Percent U8 C, R, T The Shutter Actuator sends the current position of the louvres to this communication object. The current position is sent approx. 5 seconds after the completion of a movement. If a new movement is started in the meantime, the current position is only sent once the last action has been completed. Louvres opened to maximum... : Intermediate position 255 : Louvres closed MYLOS Building Automation Operation of communication objects 11
12 Operation of communication objects 6 Recall position 1 or 2 Output 1 bit DPT Switch C, W 7 Recall position 3 or 4 Output 1 bit DPT Switch C, W If a telegram is received at this communication object, the shutter/blind is moved to the stored preset position. In the Blinds operating mode, the louvre adjustment is carried out according to the preset position once the position has been reached. If a telegram with the value 0 is received, the shutter/blind moves to position 1 (or position 3). If a telegram with the value 1 is received, the shutter/blind moves to position 2 (or position 4). Move to position 1 or Move to position 3 1 : Move to position 2 or Move to position 4 8 Store position 1 or 2 Output 1 bit DPT Switch C, W 9 Store position 3 or 4 Output 1 bit DPT Switch C, W If a telegram is received at this communication object, the current position of the shutter/blind is adopted as the new preset value. If a telegram with the value 0 is received, the current position is stored as the new preset value for position 1 (or position 3). If a telegram with the value 1 is received, the current position is stored as the new preset value for position 2 (or position 4). If position 1 or 2 is now recalled (position 3 or 4), the shutter/blind moves to the new preset values. The modified preset values are retained on bus voltage failure. After programming the Shutter Actuator, the preset values are reset to the values that were parameterised during the project design stage or the values adapted in operation are stored, depending parameterization. Set position 1 or Set position 3 1 : Set position 2 or Set position 4 10 Upper limit switch Output 1 bit DPT Start C, R, T The Shutter Actuator sends the information to this communication object as to whether the shutter/blind is located in the upper limit position or not. The current position is sent approx. 1 second (plus the switch on duration of the louvre adjustment if applicable) after the upper limit position has been reached or left. If a new movement is started in the meantime, the current position is only sent once the last action has been completed. Shutter/blind not in upper limit position 1 : Shutter/blind in upper limit position 12 Operation of communication objects MYLOS Building Automation
13 Table of 8 bit scene telegram codes 4 Table of 8 bit scene telegram codes Bit no Bit no Bit Values Hexadecimal Recall/Store Not defined Scene number Scene no. Recall (A)/ Store (S) A A A A A A A A A A 10 0A A 11 0B A 12 0C A 13 0D A 14 0E A 15 0F A A A A A A A A A A A 26 1 A A 27 1B A 28 1C A 29 1D A 30 1E A 31 1F A A A A A A A A A A A 42 2 A A 43 2B A 44 2C A 45 2D A 46 2E A 47 2F A A A A A A A A A A A 58 3A A 59 3B A 60 3C A 61 3D A 62 3E A 127 7F A S S S S S S S S S S 138 8A S 139 8B S 140 8C S 141 8D S 142 8E S 143 8F S S S S S S S S S S S 154 9A S 155 9B S 8-Bit Values Hexadecimal Recall/Store Not defined Scene number Scene no. Recall (A)/ Store (S) 156 9C S 157 9D S 158 9E S 159 9F S 160 A S 161 A S 162 A S 163 A S 164 A S 165 A S 166 A S 167 A S 168 A S 169 A S 170 AA S 171 AB S 172 AC S 173 AD S 174 AE S 175 AF S 176 B S 177 B S 178 B S 179 B S 180 B S 181 B S 182 B S 183 B S 184 B S 185 B S 186 BA S 187 BB S 188 BC S 189 BD S 190 BE S MYLOS Building Automation Table of 8 bit scene telegram codes 13
14 Contact us ABB SACE A division of ABB S.p.A. Wiring accessories, Home & Building automation Viale dell Industria, Vittuone (MI), Italy Tel.: Fax: The data and illustrations are not binding. We reserve the right to modify the contents of this document on the basis of technical development of the products, without prior notice. Copyright 2012 ABB. All rights reserved. 2CSN600008D from Monday to Saturday from 9.00 to 19.00
ABB i-bus KNX Analogue Input AE/A 2.1
Product Manual ABB i-bus KNX Analogue Input AE/A 2.1 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/A 2.1. Subject to changes and errors excepted. Exclusion
More informationOPERATING MANUAL. EIB-Kombisensor AS 315 N
EIB-Kombisensor AS 315 N OPERATING MANUAL EIB-Kombisensor AS 315 N 1 Contents Page 3 1. Description 4 1.1 Automated Operations 1.1.1 Sun System 1.1.2 Half-Light System 5 1.1.3 Wind System 1.1.4 Rain System
More informationISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER
ISOCON-6 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting
More informationISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER
ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER CAUTION: This equipment is designed for connection to mains voltages and must be used in accordance with this guide. If it is not, the safety protection
More informationOverload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011
SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with
More informationPHASED OUT. FL ballasts Electronic dimming. PCA TC BASIC Y II, W BASIC compact
EL Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A BAT Noise-free precise control via DSI signal, switchdim or corridorfunction Nominal life
More informationMotors Automation Energy Transmission & Distribution Coatings. Servo Drive SCA06 V1.5X. Addendum to the Programming Manual SCA06 V1.
Motors Automation Energy Transmission & Distribution Coatings Servo Drive SCA06 V1.5X SCA06 V1.4X Series: SCA06 Language: English Document Number: 10003604017 / 01 Software Version: V1.5X Publication Date:
More informationLD-LP-LL-LC Rope Safety Switches with reset for emergency stop
TECHNICA DATASHEET D-P--C Rope Safety Switches with reset for emergency stop Metal or polymer housing, from one or three conduit entries Protection degree IP6 In conformity with EN ISO 13850 contact blocks
More informationEIB-Combi-Sensor AS 315 N. Operatingmanual. The right to implement changes is reserved. Rev.03-03/2013 vm. by Somfy GmbH. EIB-Combi-sensor AS 315 N
EIB-Combi-Sensor AS 315 N Operatingmanual Rev.03-03/2013 vm by Somfy GmbH The right to implement changes is reserved. 1 Contents 1 Description...3 1.1 Automated Operations...4 1.1.1 Sun System...4 1.1.2
More informationEmergency lighting units EM Inverter
T T TC- TC-F DE TC- TC-SE TC-TE TC-DD Tc EM G, 0 0 V 0/0 Hz BASIC version Product description Emergency lighting supply unit for manual testing For linear and compact fluorescent lamps ow-profile casing
More informationRemote Display Unit. Installers Handbook Copyright 2001 AirSense Technology Ltd. LM Remote Display Unit Installers Handbook Issue 1.
Remote Display Unit Installers Handbook Copyright 2001 AirSense Technology Ltd AirSense, ClassiFire, FastLearn PipeCAD, SenseNET, Stratos-HSSD and Stratos-Quadra are trademarks. HSSD is a Registered Trademark.
More informationFL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact
FL ballasts EL HE PC TC PRO sr 1/2x11 42 W PC PRO compact Product description CELMA Energy Efficiency Index A2 BAT / A2 T Nominal life-time up to 50,000 h (at ta 50 C with a failure rate max. 0.2 % per
More informationMinute Impulse Clock Controller I01DN
99b-mi USER S MANUAL Minute Impulse Clock Controller Mon Jun 01, 2009 12:00:00 PM DST HOLD ENTER KEY TO BEGIN CANCEL HR I01DN 97 West Street Medfield, MA 02052 U.S.A. (508) 359-4396 Pg. 2 of 20 TABLE OF
More informationDIGITAL ABBE REFRACTOMETER INE-WYA-2S OPERATING INSTRUCTION PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION
DIGITAL ABBE REFRACTOMETER INE-WYA-2S OPERATING INSTRUCTION PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com MRC.11.16
More informationSoftware BioScout-Calibrator June 2013
SARAD GmbH BioScout -Calibrator 1 Manual Software BioScout-Calibrator June 2013 SARAD GmbH Tel.: ++49 (0)351 / 6580712 Wiesbadener Straße 10 FAX: ++49 (0)351 / 6580718 D-01159 Dresden email: support@sarad.de
More informationSKF actuators available for quick delivery. Selection guide
SKF actuators available for quick delivery Selection guide A wide range of SKF actuators available for quick delivery Industrial actuator 24 Volt DC Load range 1 000 to 4 000 N Speed range 5 to 52 mm/s
More informationDewpoint Meter Data Sheet / Instructions
Paint Test Equipment Dewpoint Meter Data Sheet / Instructions Dewpoint Meter Information ISO 8502-4: Preparation of steel substrates before application of paints and related products. Tests for the assessment
More informationFL ballasts Electronic dimming. PCA TC ECO Y II, W ECO compact
FL ballasts EL TC-F TC-SEL TC-L HE TC-DD Tc PCA TC ECO Y II, 7 W ECO compact Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A BAT Noise-free
More informationLamp and Control Panel (Lamp Panel)
www.reinhausen.com Lamp and Control Panel (Lamp Panel) Operating Instructions BA 47/0 EN NOTE! Changes may have been made to a product after going to press with this documentation. We expressly reserve
More informationHD2016. [ GB ] Weighing rain gauge. Rain PART OF G H M GROUP TELEMETRIE & AUTOMATION TELEMETRIE & AUTOMATION
HD2016 [ GB ] Weighing rain gauge Rain PART OF G H M GROUP TELEMETRIE & AUTOMATION TELEMETRIE & AUTOMATION [ GB ] HD2016 Weighing rain gauge [ GB ] HD2016 is a rain gauge that detects the weight of the
More informationData Sheet / Instructions. Dewpoint MeterO
Data Sheet / Instructions Dewpoint MeterO Dewpoint Meter ISO 8502-4: Preparation of steel substrates before application of paints and related products. Tests for the assessment of surface cleanliness.
More informationAn Introduction to Insulation Resistance Testing
An Introduction to Insulation Resistance Testing In a perfect world, electrical insulation would allow no current to flow through it. Unfortunately, a number of factors can over time result in the deterioration
More informationE6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders
Multi-turn High-precision Encoder Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders Reset function for easy origin alignment when built-into equipment. Multi-turn
More informationPOINTS OF CAUTION BEFORE USE...
INSTRUCTION MANUAL NPN DISCRETE INPUT & NPN TRANSISTOR OUTPUT MODULE, 6 points each (-I/-II, e-con connector) MODEL BEFORE USE... Thank you for choosing M-System. Before use, check the contents of the
More informationNR ROTARY RING TABLE: FLEXIBLE IN EVERY RESPECT
NR FREELY PROGRAMMABLE ROTARY TABLES NR ROTARY RING TABLE All NR rings allow customer-specific drive motors to be connected NR ROTARY RING TABLE: FLEXIBLE IN EVERY RESPECT WHEN IT S GOT TO BE EXACT We
More informationMinimum (-31) every 10 s -35 (-31)
Humidity, and Dew Point Data Logger with LCD ORDERING INFORMATION Standard Data Logger (Data Logger, Software on CD, Battery) Replacement Battery EL-USB-2-LCD BAT 3V6 1/2AA FEATURES 0 to 100 measurement
More informationLED light engine / OLED LED compact. Uengine DLE G2 integrated ADV
Uengine DLE G2 integrated ADV uengine DLE Product description Module with integrated electronics For downlights Light engine operating with 23 V AC Luminous flux range from 1,24 2,43 lm High system efficacy
More information32 Input AC Block I/O Module
Input AC Module Cat. No. 79-A0 Series B Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air to flow through
More informationAcceleration/Velocity/Displacement VIBRATION METER
Acceleration/Velocity/Displacement VIBRATION METER Model : VB-8220 Your purchase of this VIBRATION METER marks a step forward for you into the field of precision measurement. Although this METER is a complex
More informationRequest Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.
Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -A - Introduction - Thank for your purchasing MITSUBISHI ELECTRIC MELPRO TM D Series Digital Protection
More informationMeteorological Station P03/3-RS485-WAGO
Meteorological Station P03/3-RS485-WAGO Technical data and notes for installation Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D-75391 Gechingen Germany Phone: +49 (0) 70 56/93 97-0
More informationDigital display Pressure range ON/OFF output Linear output Model No Positive pressure 0 to 98 kpa (0 to 1 kgf/cm 2 ) NPN open collector o 1 to o5
Pressure Sensor E8CC with Built-in Microcomputer and Digital Display and New E8CB General-purpose Model Withstands a of 490 kpa (5 kgf/cm 2 ) and highly reliable. Incorporates a two-turn adjuster ensuring
More informationMicrocare LCD Solar MPPT User Documentation
Microcare LCD Solar MPPT User Documentation 1 CONTENTS 1. INTRODUCTION. 3 1.1. General Description 1.2. Key Features 1.3. Important Notices 1.4. Recommended Array Sizes 1.5. MPPT Description 1.6. MPPT
More informationTunable White LED compact
Module TW DLE G2 60mm 3000lm 927-965 DLE modules Product description module for Downlights with adjustable colour temperature from 2,700 to 6,500 K at constant luminous flux High colour rendering index
More informationTHREE PHASE CAPACITOR For WIND TURBINES
RS/Cond 28.04.2003 Pg: 1 / 3 THREE PHASE CAPACITOR For WIND TURBINES Applications: Three-phase capacitor for Wind Turbine has been designed for power factor correction in high harmonic current content.
More informationInstruction. Vacuum Circuit Breaker Operator Module. Type 3AH 4.16kV to 38kV. Power Transmission & Distribution
Instruction 0001-22-2--00 Vacuum Circuit Breaker Operator Module Type 3AH 4.16kV to 38kV Power Transmission & Distribution Hazardous voltages and high-speed moving parts. Will cause death, serious injury
More informationRotary modules.
Rotary modules www.comoso.com www.comoso.com Rotary modules ROTARY MODULES Series Size Page Rotary modules RM swivel unit 156 RM 08 160 RM 10 162 RM 12 164 RM 15 168 RM 21 172 RM rotor 176 RM 50 180 RM
More informationOperating Instructions for Digital Manometer. Model: MAN-SD
Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5
More informationLEDlight 30 W Universal dimmable series
LEDlight 30 W Universal dimmable series L05031 Lumotech technology Lumotech LED drivers are designed to efficiently power and control LED solutions for general lighting applications. System reliability
More informationPC Control / Touch Control
PC Control / Touch Control Version 6.0 / 5.840.0150 New Features Manual 8.840.8007EN Metrohm AG CH-9101 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 info@metrohm.com www.metrohm.com
More informationMODEL: R7K4FML3. Remote I/O R7K4F Series. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.)
Remote I/O R7KF Series I/O MODULE (-III) POWER INPUT DC power R: V DC (Operational voltage range: ±0 %; ripple 0 %p-p max.) 0 (8.7). (.) 7(.8) mm (inch) [] OPTIONS (multiple selections) Output data read
More informationSingle cam type. Double cam type. Grip force N. Type Model/size Stroke Screw type straight style. Screw type tee style
Type Model/size Stroke -SS-0-N. -SS-0-N. Single cam type -SS- 7. -SS-. -SS-4. -SD-0 Double cam type -SD- -SD-4. Screw type straight style Screw type tee style -FS- -FT- -FS- -FT- 0.9 1. 1.. 1. 4 Grip forcen
More informationDrive electronics pq12
Drive electronics pq12 Amplifier module with constant current controller for proportional valves Control of one solenoid Easy mounting directly on bearing rails acc. to EN 50022 Standard voltage and current
More informationImpedance relay and protection assemblies
RXZK 21H, 22H, 23H 509 006-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE970175) (SE970184) Features Micro-processor based impedance relay with R and X settings
More informationWeather Station P03/3-RS485-GPS with RS485 Interface
Weather Station P03/3-RS485-GPS with RS485 Interface Technical data and notes for installation Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D-75391 Gechingen Germany Phone: +49 (0)
More informationWeather Station P03/3-RS485 with RS485 Interface
Weather Station P03/3-RS485 with RS485 Interface Technical data and notes for installation Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D-75391 Gechingen Germany Phone: +49 (0) 70
More informationVK2 volume flow controller Overview
New option with sound attenuator Maintenance-free VK2 volume flow controller that operates without an auxiliary power supply, for ventilation and air conditioning systems. Adjustable on site. Outstanding
More informationDS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.
DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link
More informationLearning to work with SPS Structured Beam. (June 14-21, 2004) Lev Uvarov
Learning to work with SPS Structured Beam (June 14-21, 2004) Lev Uvarov Structured Test Beam at SPS From Minutes of SPS Users Meeting, Thursday, 17-Jun-2004: Beam conditions for SPS 25ns run (Monday, June
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for
More information16 Input AC Block I/O Module
6 Input AC Module Cat. No. 79-6A0 Series B Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air flow through
More informationSelf-Testing Prevectron 2 Millenium Lightning Conductor Set-up and Installation Manual
Self testing Prevectron 2 Millenium Lightning Conductor ENGLISH Self-Testing Prevectron 2 Millenium Lightning Conductor Set-up and Installation Manual S6.60T S4.50T S3.40T N.B. : Information and Specifications
More informationDIN Timers TD. Options and ordering codes. Specification
DIN imers D 17.5mm or 22.5mm DIN rail mounting Electronic imers Wide coil operation, 24V to 320V AC/DC Multi ime range / Multi function ON-Delay, OFF-Delay, Asymetrical, Star/Delta versions Perfect to
More informationLEDlight 20 W Universal dimmable series
LEDlight 20 W Universal dimmable series L05011i2 / L05011i3 / L05011i4 Lumotech technology Lumotech LED drivers are designed to efficiently power and control LED solutions for general lighting applications.
More informationCTC 155 / 350 / 660 Dry-block calibrator
CTC 155 / 350 / 660 Dry-block calibrator Wide temperature range: CTC-155: -25 to 155 C CTC-350: 28 to 350 C CTC-660: 28 to 660 C Fast calibration External reference sensor External sensor control Easy
More informationPushbutton Units and Indicator Lights
Insert labels and insert caps Clear, illuminated and indicator lights can be fitted with insert labels and caps for identification purposes. These labels and caps are made of a semi-transparent molded
More informationSuperCELL Data Programmer and ACTiSys IR Programmer User s Guide
SuperCELL Data Programmer and ACTiSys IR Programmer User s Guide This page is intentionally left blank. SuperCELL Data Programmer and ACTiSys IR Programmer User s Guide The ACTiSys IR Programmer and SuperCELL
More information4 - Way Acceptance Low Maintenance Easy Installation Re - Programmable Flash ROM Auto Self -Adjusting Sensor System
B V alidator ill ill alidator A6&V6 Series Installation Guide 4 - Way Acceptance Low Maintenance Easy Installation Re - Programmable Flash ROM Auto Self -Adjusting Sensor System 2003 International Currency
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationKNX communication protocol
KNX communication protocol User manual 1MNUPRKNX001 Limitation of Liability The Manufacturer reserves the right to modify the specifications in this manual without previous warning. Any copy of this manual,
More informationThermal-Magnetic Circuit Breaker 2210-T2...
Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring
More information- compressed air plants (refrigerating/adsorption dryers) - granulate dryers - medical gases - non-corrosive gases, e. g. nitrogen
INSTRUCTION MANUAL FA 510 The CS dew point sensor FA 510 with 3-wire technology 4 20 ma and RS 485 output enables a reliable and long-term stable monitoring of the dew point in industrial applications
More informationLED light engine / OLED LED compact. Module DLE G4 ADV Modules DLE
w LED light engine / OLED Module DLE G4 ADV Modules DLE Product description For downlights Luminous flux up to 3,71 lm at tp = 65 C High efficacy up to 185 lm/w for the LED module at tp = 25 C High system
More informationFLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:
abc instruments international FLT5A Thermometer Land Instruments International Dronfield, S18 1DJ England Telephone: (1246) 417691 Facsimile: (1246) 41585 Email: infrared.sales@landinst.com Internet: www.landinst.com
More informationSINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol
with PROFIBUS-PA procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application 00 II () G FISCO The SINEAX VK 66 is a temperature transducer for use in aumation systems
More informationHMS-5000 Manual. Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K. - Manual version: ver 5.
HMS-5000 Manual Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K - Manual version: ver 5.01- www.ecopia21.co.kr - Table of contents - 1. Hardware Installation
More informationQUANTUM CONCEPT. Swimming User s Manual
QUANTUM CONCEPT Swimming User s Manual 480.508.0 Version.4 Edition July 05 Documentation Updates Swiss Timing Ltd. reserves the right to make improvements in the products described in this documentation
More informationLatest generation testo air velocity & IAQ probes with cable handle. Instruction manual
Latest generation testo air velocity & IAQ probes with cable handle Instruction manual Contents Contents 1 About this document... 5 2 Safety and disposal... 5 3 System description... 6 4 Description of
More informationFL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, W EXCEL T5
F ballasts E PCA EXCE oneall lp Y II, 1 80 W EXCE Product description Processor-controlled ballast with y II inside Highest possible energy class CEMA EEI = A1 BAT 1 oise-free precise control via I or
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationHMS-5000 Manual. Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K. - Manual version: ver 5.
HMS-5000 Manual Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K - Manual version: ver 5.01- www.ecopia21.co.kr - Table of contents - 1. Hardware Installation
More informationHeat Meter WR 200-D. 2 temperature inputs for Pt100 in four-wire circuit. Exact calculation of the heat parameters according IAPWS-IF97
Heat Meter WR 200-D electronic computing device for heat quantity measuring Heat transfer medium water steam Any flow sensor with analog signal connectable 2 temperature inputs for Pt100 in four-wire circuit
More informationAcceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202
Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202 Your purchase of this VIBRATION METER marks a step forward for you into the field of precision measurement. Although this METER is
More informationIssued August DATA SHEET. 3VT3 MCCB up to 630 A
ssued August 9 DATA SHEET VT MCCB up to 6 A Based on Siemens Catalog V 6 8 Circuit breakers Switch disconnectors Technical specifications Specifications Type VT 76-AA6/6/56-AA, VT 76-AA6/6/56-AA Circuit
More informationTo order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle
otor protection relays - T - FWIT Since % of -phase motor failures are due to load problems or loss of phase, the CROUZET range of motor protection relays is indispensable! models give motor protection
More information3VT4 Molded Case Circuit Breakers up to 1000 A
VT4 Molded Case Circuit Breakers up to 00 A Catalog Technical nformation VT4 Molded Case Circuit Breakers up to 00 A General data / - Overview Circuit breakers Switch disconnectors / - Selection and ordering
More information5SJ4...-.HG Circuit Breakers to IEC and UL 489
Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is
More informationSafety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.
Safety Precautions Observe the following notices to ensure personal safety or to prevent accidents. To ensure that you use this product correctly, read this User s Manual thoroughly before use. Make sure
More informationBright Advance Corporation
USER INSTRUCTIONS TABLE OF CONTENTS INSTRUCTIONS FOR USE2 PREPARING TO USE THE SCALE2 DISPLAYS3 KEYBOARD FUNCTION4 OPERATION7 COUNTING14 DIFFERENT KEYBOARD TYPES21 INTERFACE31 POWER SOURCES40 1 INSTRUCTIONS
More informationOperating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014
Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM8004 80003223 / 00 05 / 2014 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...4 3 Functions and features...5
More informationSiemens AG Miniature Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.
Siemens AG 05 Totally Integrated Power SENTRON Configuration Manual Edition 0/0 siemens.com/lowvoltage Siemens AG 05 Siemens AG 05 Introduction 5SL miniature circuit breakers 5SY and 5SP miniature circuit
More informationISSP User Guide CY3207ISSP. Revision C
CY3207ISSP ISSP User Guide Revision C Cypress Semiconductor 198 Champion Court San Jose, CA 95134-1709 Phone (USA): 800.858.1810 Phone (Intnl): 408.943.2600 http://www.cypress.com Copyrights Copyrights
More informationVIBRATION TACHOMETER OPERATION MANUAL. 3 in 1. Model : VT Your purchase of this
3 in 1 VIBRATION TACHOMETER Model : VT-8204 Your purchase of this VIBRATION TACHOMETER marks a step forward for you into the field of precision measurement. Although this VIBRATION TACHOMETER is a complex
More informationVIBRATION METER. Instruction Manual.
VIBRATION METER 840063 Instruction Manual CONTENTS Title Page I. Introduction... 2 II. Panel Description... 3 III. Operating Instructions A. General Measurement Procedures... 3~4 B. Peak... 5 C. Data Hold...
More informationHumidity, and Dew Point Data Logger with LCD ORDERING INFORMATION Standard Data Logger (Data Logger, Software on CD, Battery) Replacement Battery EL-USB-2-LCD BAT 3V6 1/2AA FEATURES 0 to 100 measurement
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available
More informatione n g l i s h
e n g l i s h e 2 0 0 7 Home & Building System Te c h n o l o g y Switching actuators Dimming actuators Binary inputs Blind actuators Heating actuators Single-room tempera t u re re g u l a t o rs Motorised
More informationE8EB-N0C2B E8EB-N0B2B
Slim Sensor CSM DS_E 1 Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree
More informationLED light engines LED compact. Module DLE G4 ADV Modules DLE
w LED light engines Module DLE G4 ADV Modules DLE Product description For downlights Luminous flux up to 6,35 lm at tp = 65 C High efficacy up to 185 lm/w for the LED module at tp = 25 C High system efficacy
More informationCalibration Routine. Store in HDD. Switch "Program Control" Ref 1/ Ref 2 Manual Automatic
4.2 IMPLEMENTATION LABVIEW 4.2.1 LabVIEW features LabVIEW (short for Laboratory Virtual Instrument Engineering Workbench) originally released for the Apple Macintosh in 1986. It is a highly productive
More informationTF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.
TF / TF -Ex Field mounted temperature transmitters, PROFIBUS PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN P R O F I PROCESS FIELD BUS B U S Input Resistance thermometer (,, -wire
More informationSCTP20 Programmable 2-Wire Temperature Transmitter, Head Mount
20 Programmable 2-Wire Temperature Transmitter, Head Mount Configurable Transmitters Description Each 20 2-wire transmitter is designed for measuring temperature using thermocouples or RTDs. The input
More informationfür for T5-Lampen fluorescent in Multi-Lamp-Technologie
Dimmbare Dimmable electronic elektronische control Vorschaltgeräte gear für for T-ampen fluorescent in Multi-amp-Technologie lamps in technology M-tec Performance characteristics Dimmable ECG in Multi-amp
More information473-SHX Dew Point Mirror
Humidity and Temperature Reference Hygrometer For Temperature up to 125 C Precise and stable chilled mirror dew point mirror technology High temperature optical components High temperature sample fan Cable
More informationNo /06e. Technical Manual Multistage-Temperature-/Differential Controller TAR x700
Technical Manual Multistage-Temperature-/Differential Controller x700 Software Version 0078 o. 5303-0/06e 700 3700 5700 9700 3700 5700 9700 l Suitable as : Multistage Controller or Differential Controller
More informationMAN-SGY-012-V11 EC 5195 Fairford Electronics Ltd - Synergy Modbus RTU Programming Manual - 22nd February 2016 Page 1 of 59.
MAN-SGY-012-V11 EC 5195 Fairford Electronics Ltd - Synergy Modbus RTU Programming Manual - 22nd February 2016 Page 1 of 59 Modbus RTU MAN-SGY-012-V11 EC 5195 Fairford Electronics Ltd - Synergy Modbus RTU
More informationLinear Shaft Motor Sizing Application Note
Linear Shaft Motor Sizing Application Note By Jeramé Chamberlain One of the most straightforward tasks in the design of a linear motion system is to specify a motor and drive combination that can provide
More informationLinear actuator Econom 2. Our intelligent model: Econom 2. Econom 2
Linear actuator Econom 2 Our intelligent model: Econom 2 Econom 2 Linear actuators Econom 2 Description Applications Facts The users of the Econom 2 come from many different industries: From architects
More informationProximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C
ASH & ALAIN INDIA PVT LTD S-00, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-000(India) Tel : 0-797575 Fax : 0-79757 E-mail : sales@ashalain.com Proximity Ideal for High Temperatures and Cleaning
More information