1 ANALYTICAL REPORT Job Number: Job Description: Gasoline Uptake Study For: IRST Commonwealth Dr. Louisville, KY Attention: Brent Hepner Heather Curbow Project Manager I hcurbow@stl-inc.com 03/21/2007 cc: Dan Parker Project Manager: Heather Curbow is a part of Severn Trent Laboratories, Inc. This report is issued solely for the use of the person or company to whom it is addressed. Any use, copying or disclosure other than by the intended recipient is unauthorized. If you have received this report in error, please notify the sender immediately at and destroy this report immediately. Severn Trent Laboratories, Inc th Street East, Tacoma, WA Tel (253) Fax (253) Page 1 of 15
2 METHOD SUMMARY Client: IRST Job Number: Description Lab Location Method Preparation Method Matrix: Solid Volatile Organic Compounds by GC/MS Toxicity Characteristic Leaching Procedure (ZHE) Purge and Trap on Leachates STL SEA STL SEA STL SEA SW B SW SW B Pensky-Martens Closed-Cup Method for Determining Ignitability STL SEA SW Matrix: Water Volatile Petroleum Products Purge-and-Trap STL SEA STL SEA NWTPH NWTPH-Gx SW B LAB REFERENCES: STL SEA = METHOD REFERENCES: SW846 - "Test Methods For Evaluating Solid Waste, Physical/Chemical Methods", Third Edition, November 1986 And Its Updates. Page 2 of 15
3 SAMPLE SUMMARY Client: IRST Job Number: Lab Sample ID Client Sample ID Client Matrix Date/Time Sampled Date/Time Received CI Agent/Gasoline Leachability 1.79 Solid CI Agent/Gasoline Water Leachability /07/ /07/ /07/ /07/ Page 3 of 15
4 Analytical Data Client: IRST Job Number: Client Sample ID: CI Agent/Gasoline Leachability 1.79 Lab Sample ID: Client Matrix: Solid Date Sampled: Date Received: 03/07/ /07/ B Volatile Organic Compounds by GC/MS -TCLP Method: Preparation: Dilution: Date Analyzed: Date Prepared: Date Leached: 8260B Analysis Batch: B 50 Leachate Batch: /13/ /13/ /08/ Instrument ID: SEA001 Lab File ID: AG31242.D Initial Weight/Volume: Final Weight/Volume: Analyte DryWt Corrected: N Result (ug/l) Qualifier MDL RL Vinyl chloride ND ,1-Dichloroethene ND Butanone ND Chloroform ND Carbon tetrachloride ND Benzene ND ,2-Dichloroethane ND Trichloroethene ND Tetrachloroethene ND Chlorobenzene ND Toluene ND m-xylene & p-xylene 44 J o-xylene 38 J Surrogate %Rec Acceptance Limits Fluorobenzene (Surr) Toluene-d8 (Surr) Ethylbenzene-d Bromofluorobenzene (Surr) Trifluorotoluene (Surr) Page 4 of 15
5 Analytical Data Client: IRST Job Number: Client Sample ID: CI Agent/Gasoline Leachability 1.79 Lab Sample ID: Client Matrix: Water Date Sampled: Date Received: 03/07/ /07/ NWTPH-Gx Volatile Petroleum Products Method: Preparation: Dilution: Date Analyzed: Date Prepared: NWTPH-Gx Analysis Batch: B 50 03/09/ /09/ Instrument ID: SEA041 Lab File ID: GX D Initial Weight/Volume: Final Weight/Volume: Injection Volume: Column ID: PRIMARY Analyte Result (mg/l) Qualifier MDL RL Gasoline 3.6 B Surrogate %Rec Acceptance Limits 4-Bromofluorobenzene (Surr) Trifluorotoluene (Surr) Ethylbenzene-d10 Fluorobenzene (Surr) Toluene-d8 (Surr) Page 5 of 15
6 Analytical Data Client: IRST Job Number: Client Sample ID: CI Agent/Gasoline Leachability 1.79 General Chemistry Lab Sample ID: Client Matrix: Solid Date Sampled: Date Received: 03/07/ /07/ Analyte Flashpoint Result Qual Units Dil Method >212 Degrees F Anly Batch: Date Analyzed 03/19/ DryWt Corrected: N Page 6 of 15
7 Quality Control Results Client: IRST Job Number: Method Blank - Batch: Lab Sample ID: MB /1 Client Matrix: Solid Dilution: 50 Date Analyzed: 03/13/ Date Prepared: 03/13/ Analysis Batch: Prep Batch: N/A Units: ug/l Method: 8260B Preparation: 5030B TCLP Instrument ID: Lab File ID: SEA001 AG31241.D Initial Weight/Volume: Final Weight/Volume: Analyte Result Qual MDL RL Vinyl chloride 1,1-Dichloroethene 2-Butanone Chloroform Carbon tetrachloride Benzene 1,2-Dichloroethane Trichloroethene Tetrachloroethene Chlorobenzene Toluene m-xylene & p-xylene o-xylene ND ND ND ND ND ND ND ND ND ND ND ND ND Surrogate % Rec Acceptance Limits Fluorobenzene (Surr) Toluene-d8 (Surr) Ethylbenzene-d Bromofluorobenzene (Surr) Trifluorotoluene (Surr) Calculations are performed before rounding to avoid round-off errors in calculated results. Page 7 of 15
8 Quality Control Results Client: IRST Job Number: Lab Control Spike - Batch: Lab Sample ID: LCS /2 Client Matrix: Solid Dilution: 50 Date Analyzed: 03/13/ Date Prepared: 03/13/ Analysis Batch: Prep Batch: N/A Units: ug/l Method: 8260B Preparation: 5030B TCLP Instrument ID: Lab File ID: SEA001 AG31239.D Initial Weight/Volume: Final Weight/Volume: Analyte Spike Amount Result % Rec. Limit Qual Vinyl chloride 1,1-Dichloroethene 2-Butanone Chloroform Carbon tetrachloride Benzene 1,2-Dichloroethane Trichloroethene Tetrachloroethene Chlorobenzene Toluene m-xylene & p-xylene o-xylene Surrogate % Rec Acceptance Limits Fluorobenzene (Surr) Toluene-d8 (Surr) Ethylbenzene-d Bromofluorobenzene (Surr) Trifluorotoluene (Surr) Calculations are performed before rounding to avoid round-off errors in calculated results. Page 8 of 15
9 Quality Control Results Client: IRST Job Number: Matrix Spike - Batch: Lab Sample ID: Client Matrix: Solid Dilution: 50 Date Analyzed: 03/13/ Date Prepared: Date Leached: 03/13/ /08/ Analysis Batch: Prep Batch: N/A Units: ug/l Leachate Batch: Method: 8260B Preparation: 5030B TCLP Instrument ID: Lab File ID: SEA001 AG31244.D Initial Weight/Volume: Final Weight/Volume: Analyte Sample Result/Qual Spike Amount Result % Rec. Limit Qual Vinyl chloride 1,1-Dichloroethene 2-Butanone Chloroform Carbon tetrachloride Benzene 1,2-Dichloroethane Trichloroethene Tetrachloroethene Chlorobenzene Toluene m-xylene & p-xylene o-xylene ND ND ND ND ND ND ND ND ND ND ND J J Calculations are performed before rounding to avoid round-off errors in calculated results. Page 9 of 15
10 Quality Control Results Client: IRST Job Number: Method Blank - Batch: Method: NWTPH-Gx Preparation: 5030B Lab Sample ID: MB /1 Client Matrix: Water Dilution: 50 Date Analyzed: 03/09/ Date Prepared: 03/09/ Analysis Batch: Prep Batch: N/A Units: mg/l Instrument ID: SEA041 Lab File ID: GX D Initial Weight/Volume: Final Weight/Volume: Injection Volume: Column ID: PRIMARY Analyte Result Qual MDL RL Gasoline 0.51 J Surrogate % Rec Acceptance Limits 4-Bromofluorobenzene (Surr) Trifluorotoluene (Surr) Ethylbenzene-d Fluorobenzene (Surr) Toluene-d8 (Surr) Lab Control Spike - Batch: Method: NWTPH-Gx Preparation: 5030B Lab Sample ID: LCS /2 Client Matrix: Water Dilution: 50 Date Analyzed: 03/09/ Date Prepared: 03/09/ Analysis Batch: Prep Batch: N/A Units: mg/l Instrument ID: SEA041 Lab File ID: GX D Initial Weight/Volume: Final Weight/Volume: Injection Volume: Column ID: PRIMARY Analyte Spike Amount Result % Rec. Limit Qual Gasoline Surrogate % Rec Acceptance Limits 4-Bromofluorobenzene (Surr) Trifluorotoluene (Surr) Ethylbenzene-d Fluorobenzene (Surr) Toluene-d8 (Surr) Calculations are performed before rounding to avoid round-off errors in calculated results. Page 10 of 15
11 Quality Control Results Client: IRST Job Number: Matrix Spike - Batch: Method: NWTPH-Gx Preparation: 5030B Lab Sample ID: Client Matrix: Water Dilution: 50 Date Analyzed: 03/09/ Date Prepared: 03/09/ Analysis Batch: Prep Batch: N/A Units: mg/l Instrument ID: SEA041 Lab File ID: GX D Initial Weight/Volume: Final Weight/Volume: Injection Volume: Column ID: PRIMARY Analyte Sample Result/Qual Spike Amount Result % Rec. Limit Qual Gasoline Calculations are performed before rounding to avoid round-off errors in calculated results. Page 11 of 15
12 Quality Control Results Client: IRST Job Number: Lab Control Spike - Batch: Method: 1010 Preparation: N/A Lab Sample ID: LCS /1 Client Matrix: Solid Dilution: 1.0 Date Analyzed: 03/19/ Date Prepared: N/A Analysis Batch: Prep Batch: N/A Units: Degrees F Instrument ID: Lab File ID: Initial Weight/Volume: Final Weight/Volume: No Equipment Assigned N/A Analyte Spike Amount Result % Rec. Limit Qual Flashpoint Calculations are performed before rounding to avoid round-off errors in calculated results. Page 12 of 15
13 DATA REPORTING QUALIFIERS Client: IRST Job Number: Lab Section Qualifier Description GC/MS VOA J Result is less than the RL but greater than or equal to the MDL and the concentration is an approximate value. GC VOA B J Compound was found in the blank and sample. Result is less than the RL but greater than or equal to the MDL and the concentration is an approximate value. Page 13 of 15
14 Page 14 of 15
15 LOGIN SAMPLE RECEIPT CHECK LIST Client: IRST Job Number: Login Number: 5165 Question T/F/NA Comment Radioactivity either was not measured or, if measured, is at or below background The cooler's custody seal, if present, is intact. The cooler or samples do not appear to have been compromised or tampered with. Samples were received on ice. NA client dropped off in SR Cooler Temperature is acceptable. NA Cooler Temperature is recorded. NA COC is present. COC is filled out in ink and legible. COC is filled out with all pertinent information. There are no discrepancies between the sample IDs on the containers and the COC. Samples are received within Holding Time. Sample containers have legible labels. Containers are not broken or leaking. Sample collection date/times are provided. Appropriate sample containers are used. Sample bottles are completely filled. There is sufficient vol. for all requested analyses, incl. any requested MS/MSDs VOA sample vials do not have headspace or bubble is <6mm (1/4") in diameter. NA If necessary, staff have been informed of any short hold time or quick TAT needs Multiphasic samples are not present. Samples do not require splitting or compositing. Page 15 of 15
ANALYTICAL REPORT. Job Number: Job Description: Old Douglas Harbor. For: PND Engineers, Inc West 36th Ave. Anchorage, AK 99503
ANALYTICAL REPORT Job Number: 580-5385-2 Job Description: Old Douglas Harbor For: PND Engineers, Inc. 1506 West 36th Ave. Anchorage, AK 99503 Attention: Ms. Jennifer Lundberg Katie Downie Project Manager
More informationANALYTICAL REPORT. Job Number: Job Description: Old Douglas Harbor. For: PND Engineers, Inc West 36th Ave. Anchorage, AK 99503
ANALYTICAL REPORT Job Number: 580-5407-2 Job Description: Old Douglas Harbor For: PND Engineers, Inc. 1506 West 36th Ave. Anchorage, AK 99503 Attention: Ms. Jennifer Lundberg Katie Downie Project Manager
More informationANALYTICAL REPORT. Job Number: Job Description: Transform Complete
ANALYTICAL REPORT Job Number: 640-4848-1 Job Description: Transform Complete For: American Master*Tech Scientific, Inc. 1330 Thurman Street PO BOX 2539 Lodi, CA 95240 Attention: Mr. Adam Kowalczyk Chad
More information* * * * * * * November 1, Pierce County Parks and Recreation Services Department 9112 Lakewood Drive SW Lakewood, WA 98499
November, 0 Pierce County Parks and Recreation Services epartment Lakewood rive SW Lakewood, WA Attn: Jessica Stone, Natural Lands Steward Transmitted via email to: jstone@co.pierce.wa.us Re: 0 Groundwater
More informationANALYTICAL REPORT. Attn: Thomas W Hensel
ANALYTICAL REPORT TestAmerica Laboratories, Inc. 0 Foster Creighton Drive Nashville, TN 0 Tel: ()-0 TestAmerica Job ID: 0-- Client Revision: For: AMEC Foster Wheeler E & I, Inc Cogdill Road Knoxville,
More informationANALYTICAL REPORT. Attn: Richard Boelter
ANALYTICAL REPORT TestAmerica Laboratories, Inc. 0 Community Drive Suite South Burlington, VT 00 Tel: (0)0-0 TestAmerica Job ID: 00-- Client For: ARCADIS U.S. Inc Massena Facility, Route East Chevrolet
More informationANALYTICAL REPORT. Attn: Richard Boelter
ANALYTICAL REPORT TestAmerica Laboratories, Inc. 0 Community Drive Suite South Burlington, VT 00 Tel: (0)0-0 TestAmerica Job ID: 00-0- TestAmerica Sample Delivery Group: 00-0- Client For: ARCADIS U.S.
More informationANALYTICAL REPORT. Attn: Richard Boelter
ANALYTICAL REPORT TestAmerica Laboratories, Inc. 0 Community Drive Suite South Burlington, VT 00 Tel: (0)0-0 TestAmerica Job ID: 00-- TestAmerica Sample Delivery Group: 00- Client For: ARCADIS U.S. Inc
More informationANALYTICAL REPORT. Attn: Richard Boelter
ANALYTICAL REPORT TestAmerica Laboratories, Inc. 0 Community Drive Suite South Burlington, VT 00 Tel: (0)0-0 TestAmerica Job ID: 00-0- TestAmerica Sample Delivery Group: 00-0 Client For: ARCADIS U.S. Inc
More informationANALYTICAL REPORT. Attn: Richard Boelter
ANALYTICAL REPORT TestAmerica Laboratories, Inc. 0 Community Drive Suite South Burlington, VT 00 Tel: (0)0- TestAmerica Job ID: 00-- TestAmerica Sample Delivery Group: 00- Client For: ARCADIS U.S. Inc
More informationDrake Petroleum Company, Inc. Accutest Job Number: JB Total number of pages in report:
e-hardcopy 2.0 Automated Report New Jersey 05/06/15 05/06/15 Technical Report for Drake Petroleum Company, Inc. 146282.003 PO#007805 Accutest Job Number: Sampling Date: 03/25/15 Report to: Brown & Caldwell
More informationANALYTICAL REPORT. Results relate only to the items tested and the sample(s) as received by the laboratory. Page 1 of 5
ANALYTICAL REPORT TestAmerica Laboratories, Inc. TestAmerica Savannah 5102 LaRoche Avenue Savannah, GA 31404 Tel: (912)354-7858 Client For: Imperial Paints LLC PO BOX 489 Fairforest, South Carolina 29336
More informationThe Phase I ESA Report provided the following recommendation regarding a diesel fuel UST connected to a backup electrical generator:
August 21, 2017 Duffield Associates, Inc. 5400 Limestone Road Wilmington, DE 19808 Phone: 302.239.6634 Fax: 302.239.8485 duffnet.com Avon Grove Charter School Administrative Offices 1 Commerce Blvd., Suite
More informationANALYTICAL REPORT. Job Number: SDG Number: Kingston Job Description: Ulster County Resource Recovery Agency
ANALYTICAL REPORT Job Number: 420-106065-1 SDG Number: Kingston Job Description: Ulster County Resource Recovery Agency For: Ulster County Resource Recovery Agency PO Box 6219 999 Flatbush Road Kingston,
More informationANALYTICAL REPORT. Job Number: Job Description: TO4-2012, RACER, GM Wilmington
ANALYTICAL REPORT Job Number: 460-43833-1 Job Description: 17338-TO4-2012, RACER, GM Wilmington For: Conestoga-Rovers & Associates, Inc. 2055 Niagara Falls Blvd., Suite 3 Niagara Falls, NY 14304 Attention:
More informationANALYTICAL REPORT. Job Number: SDG Number: Job Description: Joint Base Cape Cod
ANALYTICAL REPORT Job Number: 200-33700-1 SDG Number: 33700 Job Description: Joint Base Cape Cod For: Dawson Technical, LLC 900 Fort Street Mall Suite 1700 Honolulu, HI 96813 Attention: Troy Hile James
More informationSome analyses have been subcontracted outside of the Pace Network. The subcontracted laboratory report has been attached.
#=CL# Pace Analytical Services, LLC Broad Hollow Road Melville, NY ()-00 LIMS USE: FR - ROB KING LIMS OBJECT ID: 0 July, 0 Rob King Hampton Bays Water District P.O. Box Hampton Bays, NY RE: Project: PFC
More informationKSA Environmental Laboratory Inc.
February 26, 07 KSA Environmental Laboratory Inc. Hydrologic Associates - Miami Attn: Brad Waller 8925 S.W. 148th Street Suite 212 Miami, FL 33176 RE: Parkland KSA Workorder: Q0012 Dear Brad Waller, Enclosed
More informationBIO-CHEM Laboratories, Inc. Work Order Sample Summary. CLIENT: CTRA Project: 6454 T Lab Order: A 6454 Aqueous 3/1/2013.
Date: 08-Mar-13 Work Order Sample Summary Lab Sample ID Client Sample ID Matrix Collection Date Date Received 1303004-01A 6454 Aqueous 3/1/2013 3/1/2013 Page 1 of 1 Date: 08-Mar-13 CASE NARRATIVE Samples
More informationAmerican Environmental Testing Laboratory Inc.
American Environmental Testing Laboratory Inc. 2834 & 2908 North Naomi Street Burbank, CA 91504 DOHS NO: 1541, LACSD NO: 10181 Tel: (888) 288-AETL (818) 845-8200 Fax: (818) 845-8840 www.aetlab.com Ordered
More informationThe following report includes the data for the above referenced project for sample(s) received on 5/15/2017 at Air Toxics Ltd.
5/26/2017 Ms. Anna Kelley Hamilton Co. Environmental Services 250 Wm. Howard Taft Cincinnati OH 45219 Project Name: Sun Coke Project #: Workorder #: 1705303 Dear Ms. Anna Kelley The following report includes
More informationLABORATORY DATA REVIEW CHECKLIST
LABORATORY DATA REVIEW CHECKLIST CS Report Name: 2012 Confirmation Sampling, Well Installation, and Groundwater Sampling, 4501 Lake Otis Parkway, Anchorage, Alaska : July 2012 Laboratory Report : 7/11/2012
More informationHow Well Do You Know Lab Reports? Making Sense Out of Seemingly Simple Lab Reports
How Well Do You Know Lab Reports? Making Sense Out of Seemingly Simple Lab Reports Railroad Environmental Conference University of Illinois at Urbana-Champaign November 1 and 2, 2016 Erin E. Rodgers Environmental
More informationalscience nvironmental aboratories, Inc.
alscience nvironmental aboratories, Inc. Page 1 of 13 June 02, 2009 Ewelina Mutkowska OTIE 317 East Main Street Ventura, CA 93001-2624 P Subject: Calscience Work Order No.: Client Reference: 09-05-2222
More informationChemical Solvents 1010 Dennison Road Cleveland, OH 44109 Chris Rander Client Project: S12054050614/2106050914 EA Group Workorder Number: 140500165 Received on May 9, 2014 The following analytical report
More informationANALYTICAL REPORT. Job Number: Job Description: TO4-2012, RACER, GM Wilmington
ANALYTICAL REPORT Job Number: 460-43877-1 Job Description: 17338-TO4-2012, RACER, GM Wilmington For: Conestoga-Rovers & Associates, Inc. 2055 Niagara Falls Blvd., Suite 3 Niagara Falls, NY 14304 Attention:
More informationACZ Laboratories, Inc Downhill Drive Steamboat Springs, CO (800)
2773 Downhill Drive Steamboat Springs, CO 80487 (800) 334-5493 Analytical Report November 19, 2004 Report to: Debbie Furlow 602 Lehmberg Road Columbus, MS 39702 Bill to: Accounts Payable PO Box 2487 Columbus,
More informationJuly 31, Dear Mr. Lurix:
July, 0 Mr. Joe Lurix Solid and Hazardous Waste Division Florida Department of Environmental Protection Southeast District Office 00 North Congress Ave, Suite 00 West Palm Beach, FL 0 Subject: Monthly
More informationImproved Volatiles Analysis Using Static Headspace, the Agilent 5977B GC/MSD, and a High-efficiency Source
Improved Volatiles Analysis Using Static Headspace, the Agilent 5977B GC/MSD, and a High-efficiency Source Application Note Environmental Authors Peter Gautschi and Harry Prest Senior Application Scientist
More informationA Single Calibration for Waters and Soil Samples Performing EPA Method Anne Jurek Applications Chemist
A Single Calibration for Waters and Soil Samples Performing EPA Method 8260 Anne Jurek Applications Chemist Abstract A Single Calibration Method for Water AND Soil Samples The United States Environmental
More informationRIGHT SOLUTIONS RIGHT PARTNER
2655 Park Center Dr., Suite A Simi Valley, CA 93065 T: +1 805 526 7161 F: +1 805 526 7270 www.alsglobal.com LABORATORY REPORT March 14, 2016 Glenn La Fevers Southern California Gas Company 12801 Tampa
More informationLaboratory Report Number(s) Lone Tree Road (Deep) 10/5/15, 10/19/15, 6/13/16. Address Sample Date(s) Analyses Requested
July 14, 216 Mr. Shaun Lehman MDEQ-OOGM Lansing District Office Constitution Hall 2 South 525 West Allegan Street Lansing, MI 48913 Re: Residential Well Sampling Hartland 36 Gas Plant SE/NE/NW Section
More informationRoger Bardsley, Applications Chemist; Teledyne Tekmar Page 1
Application Note US EPA Method 524.2 with the Teledyne Tekmar Lumin P&T Concentrator and Agilent 7890B GC / 5977A MS Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1 Abstract US EPA Method
More informationUS EPA Method 8260 with the Tekmar Atomx XYZ P&T System and Agilent 7890B GC/5977A MS
Application Note US EPA Method 8260 with the Tekmar Atomx XYZ P&T System and Agilent 7890B GC/5977A MS Author Amy Nutter Applications Chemist, Teledyne Tekmar Abstract US EPA Method 8260 in conjunction
More informationEPA TO-17 Volatile Organic Compounds
EPA TO-17 Volatile Organic Compounds Method TO-17 is used to analyze samples for volatile organic compounds collected on multi-bed sorbent tubes, which are thermally desorbed and cryo-focused on the capillary
More informationBIO-CHEM Laboratories, Inc. Work Order Sample Summary. CLIENT: Cascade Thornapple River Assoc. Project: Water Analysis Lab Order:
Date: 31-Jul-18 Work Order Sample Summary Lab Sample ID Client Sample ID Matrix Collection Date Date Received 1807123-01A Dam & Burger Water 7/25/2018 7/25/2018 1807123-02A 48th & RR Water 7/25/2018 7/25/2018
More informationUS EPA Method with the Tekmar Lumin P&T Concentrator, AQUATek LVA and Agilent 7890B GC/5977A MS
APPLICATION NOTE: TECHNOLOGY: INDUSTRY: AN1806 P+T VOC ENV US EPA Method 524.2 with the Tekmar Lumin P&T Concentrator, AQUATek LVA and Agilent 7890B GC/5977A MS Amy Nutter, Applications Chemist; Teledyne
More information2655 Park Center Dr., Suite A Simi Valley, CA 93065 T: +1 805 526 7161 F: +1 805 526 7270 www.alsglobal.com LABORATORY REPORT January 7, 2016 Glenn La Fevers Southern California Gas Company 12801 Tampa
More informationTarget Compound Results Summary
Phone/ (86)88-4800 / (86)88-471 http://www.emsl.com to1lab@emsl.com Customer ID: EMSL0A K12312.D 28 cc 0 0/01/2017 K12327.D 21 cc 600 Target Compound Results Summary Propylene 11-07-1 42.08 ND.0 ND 8.6
More informationAPPENDIX D Laboratory Analytical Reports
Allied Aviation Initial Abatement Report, Arlington, VA December 4, 2015 Amec Foster Wheeler Project 37650016 APPENDIX D Laboratory Analytical Reports #=CL# LIMS USE: FR - JOHN MITTAUER LIMS OBJECT ID:
More informationMethod 8260C by Purge and Trap Gas Chromatography Mass Spectrometry using the Clarus SQ 8
application Note Gas Chromatography/ Mass Spectrometry Authors Ruben Garnica Dawn May PerkinElmer, Inc. Shelton, CT USA Method by Purge and Trap Gas Chromatography Mass Spectrometry using the Clarus SQ
More informationJanuary 19, Dear Mr. Nightingale:
January 19, 2011 Mr. Steven F. Nightingale, P.E. Manager, Permit Section Illinois Environmental Protection Agency Bureau of Land 1021 North Grand Avenue East Springfield, Illinois 62794 Subject: Supplemental
More informationPerformance of a Next Generation Vial Autosampler for the Analysis of VOCs in Water Matrices
Application Note Performance of a Next Generation Vial Autosampler for the Analysis of VOCs in Water Matrices Abstract By: Ed Price In today s laboratories, increased efficiency and productivity are of
More informationBuilding 280A and Building 450 Soil Sampling Results Richmond Field Station Site Berkeley Global Campus at Richmond Bay, Richmond, California
TETRA TECH, INC. February 5, 2016 Lynn Nakashima Berkeley Regional Office 700 Heinz Avenue, Suite 200C Berkeley, California 94710 Subject: Building 280A and Building 450 Soil Sampling Results Richmond
More informationDHL Analytical received 2 sample(s) on 6/18/2009 for the analyses presented in the following report.
June 26, 2009 Charles E. Martin 11370 Breininger Road Hicksvile, OH 43526 TEL: (419) 542-6645 FAX: (419) 542-6475 Order No: 0906168 RE: Dear Charles E. Martin: DHL Analytical received 2 sample(s) on 6/18/2009
More informationAnalysis of Volatile Organic Compounds in Soil Samples by EPA Method 8260 with The Stratum PTC and SOLATek 72 Multi-Matrix Autosampler
Analysis of Volatile Organic Compounds in Soil Samples by EPA Method 8260 with The Stratum PTC and SOLATek 72 Multi-Matrix Autosampler Application Note By: Teri Dattilio Introduction Purge and Trap concentration
More informationRoger Bardsley, Applications Chemist; Teledyne Tekmar P a g e 1
Application Note US EPA Method 524.4 with the Tekmar Lumin P & T Concentrator and Thermo Scientific TRACE 1310 GC and ISQ LT MS System Roger Bardsley, Applications Chemist; Teledyne Tekmar P a g e 1 Abstract
More informationMethanol Extraction of high level soil samples by USEPA Method 8260C
Methanol Extraction of high level soil samples by USEPA Method 8260C Abstract In order to determine the concentration of Volatile Organic Compounds (VOCs) in soil and waste samples the USEPA developed
More informationValidation of USEPA Method 8260C Using Teledyne Tekmar Atomx, and Perkin-Elmer Clarus 600 GC/MS
Validation of USEPA Method 8260C Using Teledyne Tekmar Atomx, and Perkin-Elmer Clarus 600 GC/MS Application Note By Tyler Trent Abstract In order to determine the concentration of volatile organic compounds
More informationDecember 30, Laboratory Report This Page is to be Stamped Introduction: This report package contains total of 5 pages divided into 3 sections:
December 30, 2018 ENVIRONMENTAL AGRICULTURAL Meadowlark Ranches Mutual Water Co. Lab ID : SP 1816365 Attn: Mike Hadley P.O. Box 606 Santa Ynez, CA 93460-0606 Customer : 2-21676 Laboratory Report This Page
More informationValidation of USEPA Method Using a Stratum PTC and the New AQUATek 100 Autosampler
Validation of USEPA Method 524.2 Using a Stratum PTC and the New AQUATek 100 Autosampler Application Note Abstract Automation is the key to increasing laboratory productivity and minimizing costs. It is
More informationValidation of Environmental Water Methods on One System: Considerations for Sample Volume, Purge Parameters and Quality Control Parameters
Validation of Environmental Water Methods on One System: Considerations for Sample Volume, Purge Parameters and Quality Control Parameters Application Note Abstract Water quality laboratories across the
More informationINNOVATIVE PRODUCTS, SUPERIOR SUPPORT. Presenter: Anne Jurek, Senior Applications Chemist, EST Analytical
INNOVATIVE PRODUCTS, SUPERIOR SUPPORT Presenter: Anne Jurek, Senior Applications Chemist,, pp, EST Analytical Air pollution is a growing problem due to the global economy and industrial development in
More informationU.S. EPA VOLATILE ORGANICS METHOD USING PURGE AND TRAP GC/MS
ENVIRONMENTAL application note U.S. EPA VOLATILE ORGANICS METHOD 524.2 USING PURGE AND TRAP GC/MS Cheri Coody, Public Health Laboratory, Mississippi State Health Department, Jackson, MS USA Michael J.
More informationIf you have any questions or concerns, please do not hesitate to contact our office at
May 22, 2015 Jeannette DeBartolomeo Environmental Compliance Specialist MDE-OCP 1800 Washington Blvd. Suite 620 Baltimore, MD 21230 RE: Groundwater and Drinking Water Results Calvert Citgo (Former Alger
More informationSUMMARY REPORT OF AIR MONITORING FOR LEED CERTIFICATION PHASE 2 SWANSFIELD ELEMENTARY SCHOOL 5610 CEDAR LANE COLUMBIA, MD PREPARED FOR:
SUMMARY REPORT OF AIR MONITORING FOR LEED CERTIFICATION PHASE 2 SWANSFIELD ELEMENTARY SCHOOL 5610 CEDAR LANE COLUMBIA, MD 21044 PREPARED FOR: HOWARD COUNTY PUBLIC SCHOOL SYSTEM 10910 ROUTE 108 ELLICOTT
More informationHelium conservation in volatile organic compound analysis using U.S. EPA Method 8260C
APPLICATION NOTE 10441 Helium conservation in volatile organic compound analysis using U.S. EPA Method 8260C Authors Andrea Caruso, 1 Tommaso Albertini, 1 Jacob A. Rebholz 2 ; 1 Thermo Fisher Scientific,
More informationSTONY HOLLOW LANDFILL, INC S. Gettysburg Ave. Dayton, OH (937) (937) Fax
STONY HOLLOW LANDFILL, INC. 2460 S. Gettysburg Ave. Dayton, OH 45418 (937) 268 1133 (937) 267 5110 Fax May 1, 2018 Ms. Jennifer Marsee Unit Supervisor Regional Air Pollution Control Agency 117 South Main
More informationSTANDARD OPERATING PROCEDURES
PAGE: 1 of 14 CONTENTS 1.0 SCOPE AND APPLICATION 2.0 METHOD SUMMARY 3.0 SAMPLE PRESERVATION, CONTAINERS, HANDLING AND STORAGE 4.0 INTERFERENCES AND POTENTIAL PROBLEMS 5.0 EQUIPMENT/APPARATUS 6.0 REAGENTS
More informationSOM01.2/Trace Volatiles SOP HW-34 EPA/Region II TABLE OF CONTENTS
SOM01.2/Trace Volatiles SOP HW-34 EPA/Region II TABLE OF CONTENTS INTRODUCTION......... 1 Scope and Applicability. 1 Summary......... 1 Data Qualifiers..... 1 Lab Qualifiers...... 2 Reviewer Qualifications.
More informationUsing Hydrogen as An Alternative Carrier Gas for US EPA 8260
Using Hydrogen as An Alternative Carrier Gas for US EPA 8260 Application Note Abstract Due to regional shortages and increasing costs of helium, the preferred carrier gas in gas chromatography, alternative
More informationAnalysis of Volatile Organic Compounds Using USEPA Method 8260 and the 4760 Purge and Trap and the 4100 Autosampler
Analysis of Volatile Organic Compounds Using USEPA Method 8260 and the 4760 Purge and Trap and the Introduction Although analysis of VOCs by purge and trap is considered a mature technique, advances in
More informationALPHA ANALYTICAL LABORATORIES. Eight Walkup Drive Westborough, Massachusetts (508)
Eight Walkup Drive Westborough, Massachusetts 01581-1019 (508) 898-9220 www.alphalab.com MA:M-MA086 NH:200301-A CT:PH-0574 ME:MA086 RI:65 NY:11148 NJ:MA935 Army:USACE CERTIFICATE OF ANALYSIS Client: Fulham
More informationValidation of USEPA Method Using a Stratum PTC, AQUATek 100 Autosampler, and Perkin-Elmer Clarus 600 GC/MS
Validation of USEPA Method 524.2 Using a Stratum PTC, AQUATek 100 Autosampler, and Perkin-Elmer Clarus 600 GC/MS Application Note By: Nathan Valentine Abstract The US EPA developed Method 524.2¹, Measurement
More informationSTANDARD OPERATING PROCEDURES
PAGE: 1 of 55 ONTENTS 1.0 OBJETIVE 2.0 APPLIABILITY 3.0 DESRIPTION 3.1 Sample ontainers, Preservative, Storage and Holding Times 3.1.1 Objective 3.1.2 Requirements 3.1.3 Evaluation Procedure 3.1.4 Action
More informationApplication News AD Quantitative Determination of Volatile Organic Compounds in Drinking Water by EPA Method with Headspace Trap GC-MS
HS-20 & GCMS-QP2010Ultra Quantitative Determination of Volatile Organic Compounds in Drinking Water by EPA Method with Headspace Trap GC-MS Introduction Volatile Organic Compounds (VOCs) refer to a group
More informationStudy of Residual Solvents in Various Matrices by Static Headspace
Application Note Abstract United States Pharmacopeia (USP) chapter is a widely used method for identifying and quantifying Organic Volatile Impurities (OVI) used in the production of pharmaceuticals.
More informationF 2: Phase 2 Soil Vapor Investigation for Potential Off Site Vapor Intrusion
F 2: Phase 2 Soil Vapor Investigation for Potential Off Site Vapor Intrusion October 31, 2014 Mr. Bob Linder Essex Property Trust, Inc. 5141 California Avenue, #250 Irvine, California 92617 Subject: Phase
More informationEA LABORATORIES EAL-M-8010A GROUP: Volatiles ANALYTICAL METHOD Halogenated Volatile Organics by Gas Chromatography Page: 1 of: 12
Halogenated Volatile Organics by Gas Chromatography Page: 1 of: 12 WHEN STAMPED IN RED, THIS IS A CONTROLLED COPY. IF STAMP IS NOT RED, VERIFY THAT YOU ARE USING THE CURRENT REVISION BEFORE PROCEEDING
More informationAnalysis. Introduction: necessary. presented. Discussion: As part of be carried. consistent and reliable data. (MoRT) to.
Optimal Conditions for USEPA Method 8260 Analysis Anne Jurek Introduction: Over the past decade, the need for environmental laboratoriess using purge and trap systems to report at or below the Method Detection
More informationAnalysis of Low Level Volatile Organic Compounds in Air Anne Jurek
JSB is an authorised partner of Analysis of Low Level Volatile Organic s in Air Anne Jurek #111 Introduction The New Jersey Department of Environmental Protection (NJDEP) developed a new low level TO-15
More informationSemiannual Groundwater Quality Monitoring Report: August 2018
Semiannual Groundwater Quality Monitoring Report: August 0 Immokalee Waste Processing Facility 00 Stockade Road Immokalee, Collier County, Florida FEP Permit No. 0000-0-SO/ WACS I for: Florida epartment
More informationA Comparison of Volatile Organic Compound Response When Using Nitrogen as a Purge Gas
A Comparison of Volatile Organic Compound When Using Nitrogen as a Gas Application Note By: Anne Jurek Abstract For many years Helium has been the gas of choice for purging Volatile Organic Compounds (VOCs).
More information/J~ GOLDER. Golder Associates Inc. golder.com. Project No April 25, 2018
GOLDER April 25, 2018 Project No. 0236105018 Canadian Pacific Plaza Attn: Aimee Zack 120 South 6th Street Suite 700 Minneapolis, MN 55402 RE: SHOREHAM YARD - SOUTHEAST PUMP & TREAT SYSTEM MCES SPECIAL
More informationAnalysis of BTEX in Natural Water with SPME
Analysis of BTEX in Natural Water with SPME Application Note Environmental Author Giordano Vassalli Sezione Protezione Aria Introduction Benzene, toluene, ethylbenzene and xylene (BTEX) isomers are monocyclic
More informationMETHOD 5021 VOLATILE ORGANIC COMPOUNDS IN SOILS AND OTHER SOLID MATRICES USING EQUILIBRIUM HEADSPACE ANALYSIS
METHOD 5021 VOLATILE ORGANIC COMPOUNDS IN SOILS AND OTHER SOLID MATRICES USING EQUILIBRIUM HEADSPACE ANALYSIS 1.0 SCOPE AND APPLICATION 1.1 Method 5021 is a general purpose method for the preparation of
More informationOptimal VOC Method Parameters for the StratUm PTC Purge & Trap Concentrator
Optimal VOC Method Parameters for the StratUm PTC Purge & Trap Concentrator Application Note Introduction Environmental laboratories have utilized the Purge & Trap sample concentration technique for over
More information2017 EPA Method Update Rule and EPA Method 624.1
Introduction Method 624 is for the determination of volatile organic compounds in industrial discharges and other liquid environmental samples by gas chromatography combined with mass spectrometry (GC/MS).
More informationAnalysis of Residual Solvents in Pharmaceuticals (USP<467>) with Shimadzu GC-2010 Plus and HS-10 Headspace Sampler
No. SSI-GC- Gas Chromatography No. GC- Analysis of Residual Solvents in Pharmaceuticals (USP) with Shimadzu GC- Plus and HS- Headspace Sampler Introduction Organic solvents are routinely used in manufacturing
More informationValidation of Volatile Organic Compound by USEPA. Method 8260C. Application Note. Abstract. Introduction. Experimental-Instrument Conditions
Validation of Volatile Organic Compound by USEPA Method 8260C Application Note Abstract In order to determine the concentration of volatile organic compounds (VOCs) in water and soil matrices the USEPA
More informationOptimizing of Volatile Organic Compound Determination by Static Headspace Sampling
JSB is an authorised partner of Optimizing of Volatile Organic Compound Determination by Static Headspace Sampling Anne Jurek Introduction: #134 Static headspace sampling has always been a viable option
More informationAUTONOMOUS, REAL TIME DETECTION OF 58 VOCS IN THE PANAMA CANAL
AUTONOMOUS, REAL TIME DETECTION OF 58 VOCS IN THE PANAMA CANAL Challenges of Water Monitoring Volatile Organic Compounds (VOCs) can have negative health impacts even at ppb levels VOC concentrations can
More informationMaximizing Sample Throughput In Purge And Trap Analysis
Maximizing Sample Throughput In Purge And Trap Analysis LINDSEY PYRON ANNE JUREK INTRODUCTION There are several demands and requirements imposed on chemists performing volatile organic analysis (VOC) in
More informationMicrobac Laboratories, Inc. - Baltimore
Tidewater Meneka Rodrigo 6625 Selnick Drive, Suite A Elkridge, MD 21075 Analytical Testing Parameters - Baltimore 18K1357 Project Name: Twin Ridge Elementary Project / PO Number: N/A Received: 11/29/2018
More informationCopies: Dave Favero, RACER File
MEMO To: Nate Nemani USEPA Region 5 77 West Jackson Boulevard Mail Code: LU-9J Chicago, Illinois 60604-3507 Copies: Dave Favero, RACER File Arcadis of Michigan, LLC 300 S. Washington Square Suite 315 Lansing
More informationOctober 26, Dear Mr. White:
ExxonMobil Environmental Services Company 38 Varick Street Brooklyn, New York 11222 October 26, 2011 New York State Department of Environmental Conservation Division of Environmental Remediation Remedial
More informationMeasuring Environmental Volatile Organic Compounds by U.S. EPA Method 8260B with Headspace Trap GC/MS
application Note Gas Chromatography Author Heidi Grecsek PerkinElmer, Inc. Shelton, CT 06484 USA Measuring Environmental Volatile Organic Compounds by U.S. EPA Method 8260B with Headspace Trap GC/MS Introduction
More informationOptimizing. Abstract: is standardd. procedures. altered to
Optimizing Standard Preparation ANNE JUREK Abstract: Standardd preparation can often be a time consuming, tedious process. The opportunity for human error or inconsistencies between individual preparation
More informationSystem and JUREK ANNE. Introduction: in an in purge and. trap sampling. Discussion: As part of. consistent and reliable data. (MoRT) to.
ANNE JUREK Optimal Conditions for USEPA Method 8260B Analysis Using the EST Analyticall Sampling System and the Shimadzu GCMS-QP2010s Introduction: The USEPA developedd Method 8260B for the determination
More informationMaine DEP DRO. MY05TP220A(0-0.5) MY05TP222A(0-0.5) FD MY05TP223A(0-0.5) FD MY05TP220A (EB) EB-Equipment Rinsate Blank FD- Field Duplicate Samples
Mr. John Rendall Maine Yankee 321 Old Ferry Road Wiscasset, Maine 04578 RE: Project No.: Maine Yankee Soil/sediment Samples Lab Name: Katahdin Analytical Services, Westbrook, Maine Site Name: Maine Yankee
More informationFor Routine Level Volatile Organic Compounds (VOC), Gasoline Range Organics (GRO) and Total Petroleum Hydrocarbons (TPH) Data Validation (pg.
Appendix F Barr Data Validation Standard Operating Procedures For Routine Level Volatile Organic Compounds (VOC), Gasoline Range Organics (GRO) and Total Petroleum Hydrocarbons (TPH) Data Validation (pg.1)
More informationExploring US EPA Method 524 Purge and Trap Variables: Water Vapor Reduction and Minimizing Cycle Time
Exploring US EPA Method 524 Purge and Trap Variables: Water Vapor Reduction and Minimizing Cycle Time Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1 Introduction Purge and Trap (P&T) concentrators
More informationChlorinated Compounds in Hydrocarbon Streams Using a Halogen Specific Detector (XSD)
Introduction There has been an increase in concern for the detection and removal of organic chloride species from crude aromatic, naphtha, and other hydrocarbon streams. One process called catalytic reforming
More informationANALYTICAL RESULTS. Project: Mayflower, AR Pipeline Incident
ANALYTICAL RESULTS Prepared by: Eurofins Lancaster Laboratories Environmental 2425 New Holland Pike Lancaster, PA 760 Prepared for: Mobil Pipeline Company PO Box 446 Houston TX 7720-446 July 30, 203 Project:
More informationGOLDER. Golder Associates Inc. Al-1!1f;s. golder.com. June 22, Project No
GOLDER June 22, 2018 Project No. 0236105018 Canadian Pacific Plaza Attn: Aimee Zack 120 South 6th Street Suite 700 Minneapolis, MN 55402 RE: SHOREHAM YARD-SOUTHEAST PUMP & TREAT SYSTEM MCES SPECIAL DISCHARGE
More informationDetection of Volatile Organic Compounds in polluted air by an Agilent mini Thermal Desorber and an Agilent 5975T LTM GC/MS
Detection of Volatile Organic Compounds in polluted air by an Agilent mini Thermal Desorber and an Agilent 5975T LTM GC/MS Application Note Environmental Author Xiaohua Li Agilent Technologies (Shanghai)
More informationResidual solvents analysis using an Agilent Intuvo 9000 GC system
Residual solvents analysis using an Intuvo GC system Technology advantage: simplified dual column analysis with Flow Chip modularity Introduction USP defines a method for analysis of residual solvents
More informationSolid Phase Micro Extraction of Flavor Compounds in Beer
Solid Phase Micro Extraction of Flavor s in Beer ANNE JUREK USEPA 524.2 Method Validation Using the Evolution Purge and Trap Concentrator and the Centurion WS Autosampler Application Note Environmental
More informationA Site Location Map and Site and Surrounding Properties Map are attached as Figure 1 and Figure 2, respectively.
February 23, 216 Mr. Shaun Lehman MDEQ-OOGM Lansing District Office Constitution Hall 2 South 525 West Allegan Street Lansing, MI 48913 Re: Groundwater Characterization Work Plan Hartland 36 Gas Plant
More information