Strength in Technology. Fortis Phase Chemistry Guide

Size: px
Start display at page:

Download "Strength in Technology. Fortis Phase Chemistry Guide"

Transcription

1 Strength in Technology Fortis Phase Chemistry Guide

2 Fortis BIO 22 page 23.indd 7//23 :35:42 Other Product Guides Available Fortis Phase Chemistry Selectivity Fortis SpeedCore - Modern Core-Shell technology - High speed separations General UHPLC use Method Development from ph -2 Acids Bases Neutrals Fortis H2o Polar endcapped Increased polar retention Hydrophilic analytes Organic acids Catecholamines New Core-Shell Technology Strength in Technology.7µm Fortis UHPLC Columns.7µ Fortis UHPLC columns - High Efficiency UHPLC particles - 8 Stationary phases for high resolution Fortis Diphenyl Unique di-phenyl structure Metabolite profiling Separate positional isomers Metabolites Positional Isomers Hydrophilic / Hydrophobic analytes Ultra High Pressure Chromatography Fortis C8 General UHPLC use Method Development Lipids Steroids Highly Hydrophobic analytes Improve your UHPLC Performance Includes.7µ FortisBIO UHPLC Columns 8 Chemistry Choices Increase Efficiency Increase Speed Improve Resolution Greater Sensitivity Lower Backpressure FortisBIO Strength in Technology Peptide & Protein Columns Strength in Technology FortisBIO - Peptide and Protein columns (3Å pore size) -.7µ for ultra high resolution separations Fortis HILIC High polar retention Homogenous silanol concentration Improve MS sensitivity Fortis HILIC Diol Alternate selectivity to bare silica Stable bonding HILIC or Normal phase mode Carboxylic acids Nucleotides Vitamins Steroids Proteins Metabolites HPLC/UHPLC Columns UniverSil - Economical alternative to older type B silicas - Excellent reproducibility Fortis Cyano Cyano functionality Reversed phase or Normal phase Explosives Pesticides Steroids Fortis Amino Reproducible, Robust bonding Reversed phase, Normal phase or Ion exchange mode Saccarides Oligonucleotides Steroids Tel: Tel: Product Guide 3

3 Si O Si O Si O Si O Si O Si O Si O Si O Si Fortis Method Development Options Choice of Stationary phase functionality Based on Ultra pure silica Reversed Phase (RP) and Normal Phase (NP) options H2o - Polar endcapped C8 - Increased polar retention - Organic acids - Catecholamines Diphenyl - Unique di-phenyl structure - Separate Positional Isomers - Metabolite profiling Method Dev Getting Started : Method development typically starts with a C8 or C8 column, both provide Hydrophobic retention with good peak shapes for neutral, acidic and basic analytes. Generally if retention of polar molecules is also needed then a polar endcapped stationary phase such as Fortis H2o is a good starting choice. If selectivity is insufficient then Diphenyl or Cyano stationary phases are a good alternative, they will change selectivity and even elution order since they work on dipole characteristics as opposed to just hydrophobicity. Fortis Cyano is good in normal phase (NP) conditions for polar analytes with CO, NH2, NHR2 or NR2 groups. If small polar molecules still do not retain then HILIC chromatography is a suitable alternative H2o Extra Polar Retention Diphenyl Change Selectivity Method Dev P P Si Si O O Si O O Si O Si O Si O Si Si O Si O Si O Si O Si Si Si Si O Si O Si O Si O Si O Si O Si O Si O Si O Si C Si 5 5 HILIC - High Polar Retention - Highly Pure Silica - Carboxylic acids - Nucleotides CN O Si O Si O Si O O Si C8 - General HPLC use - Method dev. from ph -2 - Acids, Bases and Neutral Si O Si O Si O Si O Si O Si O Si O Si O Si Si O Si O Si O Si O Si O Si O Si O Si O Si O O HILIC DIOL - High Polar Retention - Highly Pure Silica - Nucleotides Cyano Extra Selectivity C8 Lower Hydrophobicity CN Si CN O Si O Si O Si O Cyano - Cyano functionality - RP or NP use - Explosives - Pesticides Si O Si O Si O Si O Si NH2 Amino - High Polar Retention - Highly Pure Silica - Carbohydrates NH2 NH2 C8 - Reduced Hydrophobicity - Lipids - Steroids Tel: Tel: Acidic, Neutral & basic analytes - - Fortis C8 - Fortis Diphenyl Polar basic molecules - operated at high ph - Fortis Diphenyl - Fortis H2o Polar acidic molecules - Fortis H2o - Fortis HILIC - Fortis Cyano in NP mode Alternate Selectivity - Fortis Diphenyl - Fortis Cyano

4 C8 Extended operating ph range Superior Peak Shapes ph Range -2 Based on Ultra Pure Silica Fully Scalable - UHPLC to Prep.7μ 2.5μ 3μ 5μ μ C8 7% Column: x4.mm 3μ p/n: F8-553 Mobile Phase: A - H 2 O +.% Formic acid B - ACN +.% Formic acid Gradient: - 5% in min ml/min Inflammation and Infection ph is a pure silica based stationary phase with unique high and low ph performance. Whether carrying out simple compound screens or complex metabolite identification will provide the best in peak shape, resolution and extended ph range for method development flexibility. Optimised Peak Shape L 38m2/g Temp: 2 C Wavelength: 254nm. Dexamethasone 2. Neomycin Sulphate 3. Acetic acid Whatever the compound functionality the optimised hydrophobic bonding of Fortis C8 leads to peak symmetries being near perfect whatever the analyte type. Basic, Acidic and Neutral analyte performance is first class across the ph spectrum. Superior Peak Shapes - Higher Efficiencies Excellent Reproducibility Column: Fortis C8 5x4.mm 5μ Luna C8(2) 5x4.mm 5μ Mobile Phase: A - H 2 O +.% Formic acid B - ACN +.% Formic acid Gradient: 25-4% in min ml/min Temp: 2 C Wavelength: 254nm. Protriptyline 2. Nortriptyline 3. Amitriptyline 4. Trimipramine Fortis C8 Luna C8(2) Column: 5x4.mm 5μ p/n: F8-535 Mobile Phase: A - 5mM NH 4 OAc B - ACN Gradient: - 4% in min ml/min Temp: 2 C Wavelength: 254nm. Quetiapine Antipsychotic - ph Extreme ph range has the ability to not only operate at low ph like other silica based phases, but also to operate at high ph like hybrid phases to aid with basic analyte retention and performance. C8 ph. Lidocaine Asy -.97 N - 2,225 Rs Column: 5x3.mm 3μ p/n: F Selective Estrogen Modulator The ability to quickly equilibrate from formic acid or TFA into ammonia or bicarbonate aids in method development. Mass transfer, loadability and precision of a silica matrix are all maintained. Higher Efficiency than Hybrids - Excellent Reproducibility Retain Polar Basic Analytes Gemini C8 ph. Lidocaine Asy -.22 N- 7,85 Rs Mobile Phase: 3:7 H 2 O + mm ammonium bicarbonate : Me.4ml/min Temp: 25 C Wavelength: MS Detection Raloxifene Glucuronides 5 ph 2 5 Columns: 5x4.mm 3μ Mobile Phase: 5:5.% NH 3 : MeCN.ml/min Temp: 25 C Wavelength: 23nm Data Courtesy of : Pharmaceutical company, USA Tel: Tel:

5 High ph Stability C8 Optimised Resolution C8 The unique bonding of enables stability at extremes of ph to be maintained. Run continuously in.% ammonia shows no deterioration in efficiency over a 9 day period. 2 8 % of original Efficiency 4 Only by optimising all factors of stationary phase design can the analyst be assured of the best possible chromatography. s unique bonded character ensures that not only is reproducibility and robustness assured, but also that resolution is of the highest level. Only by obtaining sharp peak shapes for many analyte types both polar and non polar can this sort of resolution be achieved..e5 5.5e5 5.e5 4.5e5 4.e5 3.5e5 3.e5 2.5e5 35 Pesticide Transitions Column: Fortis C8 5x2.mm 3μ 2 Day Day Day 2 Day 3 Day 4 Day 5 Day Day s running at ph. Day 7 Day 8 Day 9 Analysed here are 35 transitions of pesticide residue from an apple matrix. Good LC resolution leads to excellent sensitivity in MS detection. Polar organophosphates such as Acephate and Methamidophos are retained well due to the high surface area of the phase. 2.e5.5e5.e5 5.e XIC of +MRM (35 pairs): 84./43. amu 5 from Sample 2 (Run39558_2) of Data39558.wiff (Turbo Spray) 5 2 Max..4e5 cps e5 4.e5 Advantages of Hydrophobicity 4.4e5 4.2e5 4.e5 Column: Atlantis dc8 C8 5x2.mm 3μ 3.8e5 high surface area combined with the optimised C8 ligand bonding provides high retention for compounds. This is advantageous in a number of ways: - Higher retention of analytes, more organic modifier can be used to elute, therefore greater MS sensitivity. - Higher retention of analytes, more organic leads to shorter dry-down in fraction collection. Fortis C8 Sunfire C8 Luna C8(2) Zorbax Eclipse XDB-8 Synergi Max-RP 3.e5 3.4e5 3.2e5 3.e5 2.8e5 2.e5 Column carryover of thiabendazole 2.4e5 2.2e5 XIC of +MRM (35 pairs): 22./75. amu from Sample (Job372_2_4) of DataTBZ_carryover2.wiff (Turbo Spray), Smoothed, Smoothed 2.e e5 4.e5.8e5 3.8e5 3.e5.e5 3.4e5.4e5 3.2e5 3.e5.2e5 2.8e5 2.e5.e5 2.4e5 8.e4 2.2e5 2.e5.e Max. 4.2e5 cps. XIC of +MRM (35 pairs): 22./75. amu from Sample (Run39558_) of Data39558.wiff (Turbo Spray), Smoothed, Smoothed 3.3e5 3.2e5 3.e5 2.8e5 2.e5 2.4e5 2.2e5 2.e5.8e5.e5.4e5.2e Higher retention of analytes, more chance of resolution Gemini C8 Ace 5C8 Xterra MS C k pentylbenzene Thiabendazole can be bound on the column from one gradient cycle to the next, the optimised hydrophobicity of means that carryover on column is greatly reduced since there is no secondary silanol activity to bind with analytes e5 4.e4.e5.e5.4e5 8.e4 2.e e5.e4.e e e4 25 Time, min.e4 2.e4 4.e4 2.e4 Thiabendazole.9% Column Carryover C Time, min Thiabendazole.9% Column Carryover Atlantis dc Time, min Intensity, cps Intensity, cps Data Courtesy of : Central Science Laboratories, UK Time, min Time, min Tel: Tel: Fortis column.9%

6 C8 C8 Analyte Loading Selectivity and Peak Shape Comparison Based on a silica template has high loading capability for those wishing either scale up to preparative separation or needing to load in order to correctly identity low level components. Having a 38m2/g surface area means that the phase chemistry will not overload causing poor peak shapes. This can be especially important in biological work where a high concentration of matrix interference is also often present Fortis C8 3µm 98 bar Loss in N = 3% Loss in N = 4% Loss in N = 2% x TIC MRM (** -> **) pst_fa_fortis.d + MRM_FA_Fortis.d Asy -.5 Fortis C8 3µm Asy -.97 Asy -.9 Column: x2.mm 3μ Mobile Phase: A - H 2 O +.% formic acid B - ACN Gradient: Temp: 3 C Wavelength: 2-35%B in 2min 35-4% in 5min 4-5% in 3min 5-9% in min MS Detection Smaller surface area phases and solidcore-shell particles can suffer from lower loading capability and potentially higher backpressure. Overload can be viewed as loss of efficiency and/or peak shape. Column: 5x3.mm Mobile Phase: H 2 O +.% formic acid : ACN.ml/min Temp: 3 C Diphenhydramine.2,.2,.5 & mg/ml Selectivity of C8 - Plant Hormones All C8 chemistries are capable of providing different selectivity. Selectivity can be just as important as efficiency, here we see radically different peak shapes and resolution regardless of C8 particle size for some plant hormones. Fortis C8 3µm KI GA3 Kinetix C8 2.µm 73 bar Loss in efficiency figures are in relation to.2mg/ml injection (Blue Trace). BA Loss in N = 4% Loss in N = 45% Loss in N = 22% IAA ABA x Counts vs. Acquisition Time (min) + TIC MRM (** -> **) pst_fa_inertsil.d + MRM_FA_Inertsil.d Asy -.23 Inertsil ODS-4 3µm Asy -.3 Asy Zopiclone 2. Diazepam 3. 7-Aminoflunitrazepam 4. Nitrazepam 5. Desmethyldiazepam. 7-Aminonitrazepam 7. -Hydroxy-midazolam 8. Midazolam 9. Clonazepam. Flunitrazepam. Alprazolam 2. Zolpidem 3.Oxazepam 4. 7-Aminoclonazepam Column: 5x2.mm Mobile Phase: A - H 2 O +.% formic acid B - Me +.% formic acid Gradient: -4% in 3min Temp: 3 C Zorbax SB-C8.8µm IAA Counts vs. Acquisition Time (min) Wavelength: MS Detection GA3 BA ABA Data Courtesy of : Major Pharmaceutical, Norway KI = Kinetin BA = Benzyladenine IAA = Indol-3-yl acetate ABA = Abscisic acid GA3 = Gibberellin acid KI F8-23xx F8-25xx F8-27xx - Column Diameter 3. F8-33xx F8-35xx F8-37xx - 4. F8-53xx F8-55xx F8-57xx F8-59xx Guards Length Column Diameter 2. DC8-2xxG 4. DC8-5xxG Data Courtesy of : Kings College, UK Replace xx - for.7µm - 2 for 2.5µm - 3 for 3µm - 5 for 5µm - for µm Tel: Tel:

7 Fortis Diphenyl Diphenyl Unique Selectivity Separate Positional Isomers No MS bleed, Stable Hydrophobic Ligand Enhanced Polar Retention Fortis Diphenyl is designed to provide characteristics which will enhance selectivity. It provides the analyst with extra retention of compounds containing aromatic functionality. Extra selectivity and retention can be found for polar substrates, along with metabolite profiling. Fortis Diphenyl is now available in.7µm particle size for UHPLC. Unique Functionality Fortis Diphenyl is based upon a unique di-phenyl functionality. Three controlled mechanisms of interaction can occur. This allows for unique resolution of closely related species, and metabolites. No complex mobile phases are necessary simplifying method development. Steric Selectivity (diphenyl arrangement).7μ 2.5μ 3μ 5μ L π-π (phenyl rings) Hydrophobicity (alkyl chain) Diphenyl 3% 38m2/g Metabolite Profiling Fortis Diphenyl s extended selectivity leads to its ability to discriminate between very closely related species, such as those often associated as metabolites or excipiants. The stationary phase s three modes of interaction allow subtle changes in positional spacing, loss or gain of an atom or functional group to be differentiated and separation to be achieved. Separate Positional Isomers Selectivity of compounds normally difficult to resolve on a hydrophobic alkyl chain stationary phase is simplified by the π-π interactions provided by the phenyl functionality. In this application two hydroxyestradiol steroids exhibit resolution from each other, which is not achievable on alkyl chain phases. No complex mobile phases are necessary. Isomer Selectivity Metabolite Resolution Alternate Selectivity Column: Fortis Diphenyl 5x4.mm 5μ p/n: FPH-575 Mobile Phase: 4: H 2 O : Me ml/min Temp: 2 C Wavelength: 2nm. 4-Hydroxyestradiol (mw=288.38) 2. 2-Hydroxyestradiol (mw=288.38) H O H O H O CH 3 H H H CH 3 H H H Fortis Diphenyl π-π High Selectivity Resolution Enhanced Sharp Peak Shapes - Highly Stable Diphenyl Ligand PET Tracer - PK (.) 39. (.). Dechlorinated PK95 2. PK95 Antiarrhythmic Quinidine 2. Dihydroquinidine 4 Diphenyl vs C8 Selectivity 2 Selectivity of the Fortis Diphenyl is radically different to that of a C8 stationary phase. Fortis Diphenyl In this pharmaceutical mixture we can see an increase in retention of the parent drug, whilst the degradents are all eluted quickly, removing them from co-elution with the parent Selectivity such as this can be extremely useful, combined with the ability to separate closely related species such as metabolites and positional isomers. Fortis C8 5 2 Column: Fortis Diphenyl 5x4.mm 5μ p/n: FPH-575 Mobile Phase: 4 : H 2 O : ACN ml/min Temp: 25 C Wavelength: MS Detection Data Courtesy of : Wolfson Molecular Imaging Centre Column: p/n: Mobile Phase: ml/min Temp: 25 C Wavelength: 235nm Fortis Diphenyl 5x4.mm 5μ FPH : 3 H 2 O +.% formic acid Me 8 Data Courtesy of : Major Pharmaceutical company, USA Tel: Tel:

8 Diphenyl Diphenyl Effect of Mobile phase choice Phenyl phase bleed Fortis Diphenyl Choice of mobile phase can be very important in a running a phenyl column. Whilst many people have standardised upon ACN as the organic modifier of choice, Me is a better choice in order to let the π-π interactions occur on the phenyl rings. Using ACN can not only suppress retention but also selectivity. It can be seen how maximum retention and resolution is obtained on Fortis Diphenyl in Me mobile phase, even greater than C8. Once the organic modifier is substituted for ACN not only is resolution reduced but also a large amount of retention is lost in relation to that lost on a C8. Rs -.2 Fortis C8 Me M in u t e s Fortis Diphenyl Me Due to the chemical nature of the charge on a phenyl ring, when placed in close proximity to a silica surface it does not tend to be a very stable bond. As the phenyl ring contains a chromaphore, UV baselines could be seriously affected if the bonding is not stable. Fortis Diphenyl is a more stable bonding process since the alkyl chain ligand removes the dipolar phenol/silica interactions. No observable MS-bleed Clean baselines No sample contamination Fortis Diphenyl Commercial Phenyl Phase Bleed Fortis Diphenyl Rs -.78 Data Courtesy of : Major Pharmaceutical company, UK M in u t e s Fortis C8 ACN Fortis Diphenyl FPH-23xx FPH-25xx FPH-27xx - Column Diameter 3. FPH-33xx FPH-35xx FPH-37xx - 4. FPH-53xx FPH-55xx FPH-57xx FPH-59xx Replace xx - for.7µm - 2 for 2.5µm - 3 for 3µm - 5 for 5µm - for µm Fortis Diphenyl Guards Length Column Diameter 2. DCPH-2xxG 4. DCPH-5xxG M in ut e s Fortis Diphenyl ACN Tel: Tel:

9 H2o C8 Fortis H2o Retention of Polars by Polar Endcapping Group Enhanced Resolution % Aqueous Compatible Fully Scalable Fortis H2o is designed to aid in the separation and retention of polar analytes. Complex mobile phase systems can be bypassed if sufficient retention can be provided by the stationary phase chemistry. Fortis H2o is designed to supply additional interaction with polar molecules which allows their successful retention. Retention of Polar analytes - Amino Acids.7μ 3μ 5μ μ Polar Endcapping L 8% 38m2/g Reduced Hydrophobicity over C8 Excellent Peak Shapes Fully Scalable Fortis C8 is designed to provide characteristics similar to but specifically for situations where less hydrophobicity is required. The same gains in peak shape, efficiency, resolution and scaleability are available providing increased productivity to the analyst. Optimised Peak Shape.7μ 3μ 5μ μ L7 C8 38m2/g 3% Fortis C8 Column : p/n :. L-Aspartic acid 2. L-Glutamic acid 3. Asparagine 4. L-Serine 5. L-Histidine. Glycine 7. L-Threonine 8. L-Alanine 9. L-Arginine. L-Gly-Tyr. L-Tyrosin Fortis H2o 5x2.mm 5μ FHO L-Valine 3. L-Methionine 4. L-Norvalin 5. L-Tryptophan. L-Phenylalanine 7. L-Isoleucine 8. L-Ornithine 9. L-Leucine 2. L-Lysine 2. Sarcosin 22. L-Proline Amino Acids Fortis C8 is optimised to provide the best possible peak shapes and efficiency. Basic, Acidic and Neutral analyte performance is first class. Higher Efficiencies Greater Reproducibility Symmetrical peak shapes - Lower Hydrophobicity Column: Fortis C8 5x4.mm 5μ p/n: F8-575 Mobile Phase: A - H 2 O +.% Formic acid B - Me +.% Formic acid Gradient: - 9% in min ml/min Temp: 25 C Wavelength: 254nm. Lamotrigine Bipolar disorders Data Courtesy of : Major Pharmaceutical Company, Austria Alternative Selectivity - Steroids Anticonvulsant Antiplatelet Fortis H2o s unique bonded character ensures that not only is reproducibility and robustness assured, but also that resolution is of the highest level. Different selectivity can also be achieved from that of our stationary phase DAD C, Sig=25, Ref=3,2 (TESTOST\TESTO2.D) H2o Column: Fortis C8 5x4.mm 5μ p/n: F8-575 Mobile Phase: 4 : H 2 O +.% formic acid ACN ml/min Temp: 25 C Wavelength: 22nm Column: Fortis C8 5x4.mm 5μ p/n: F8-575 Mobile Phase: 25 : 75 H 2 O : ACN ml/min Temp: 25 C Wavelength: 254nm Column: p/n: Mobile Phase: Fortis H2o 5x2.mm 3μ FHO-273.2ml/min Temp: 25 C Wavelength: DAD DAD C, Sig=25, Ref=3,2 (TESTOST\TESTO27.D) C8. Valproate Semisodium. Clopidogrel Data Courtesy of : AstraZeneca, UK Tel: Tel:

10 Cyano HILIC Fortis Cyano Retention of Polars Alternative Selectivity Normal Phase or Reverse Phase system Rapid Equilibration Fortis Cyano allows the use of aqueous reversed phase conditions to provide less retention for compounds too heavily retained on C8 functionality. However, it can also be used in normal phase solvent systems to retain and separate polar analyte species. Cyano columns are particularly useful for polar species. Fortis Cyano is now also available in.7µm particle size for UHPLC work. Herbicides.7μ 3μ 5μ L Cyano 38m2/g 7% Retention of Polar Compounds Increased MS Sensitivity Alternate Selectivity Reduced Extraction (SPE) and Dry Down Times. Fortis HILIC (Hydrophilic Interaction Chromatography) is designed to aid in the separation and retention of very polar analytes. Extended retention is afforded by the partitioning, ion-exchange and hydrogen bonding that can occur on a HILIC stationary phase. Fortis HILIC can increase sensitivity in MS analysis and provide alternate selectivity to that achieved with reversed phase C8. Fortis HILIC is now also available in.7µm particle size for UHPLC work. Polar retention in HILIC mode.7μ,3μ, 5μ L3 HILIC 38m2/g na Fortis HILIC Fortis Cyano is optimised not only to help retain and resolve polar analytes, but also to be complimentary in resolution to other Fortis phases. Normal phase as well as Reversed phase use Alternative Selectivity Rapid Equilibration Fortis Cyano Column : Fortis Cyano 5x2.mm 3μ p/n : FCN-233 Mobile Phase: 8:2 H 2 O : ACN +.2% Acetic acid Flow :.2ml/min Temp : 2 C Wavelength: 28nm. Banvel 2. Internal Std 3. 2,4-D 4. MCPA 5. PCOC. 2,4-DCP 7. 2,4-DP 8. CMPP 9. 2,4-DB. MCPB FCN-23xx FCN-25xx FCN-27xx - Column Diameter 3. FCN-33xx FCN-35xx FCN-37xx - Herbicides Fortis Cyano Guards Length Column Diameter 2. DCCN-2xxG 4. DCCN-5xxG Fortis HILIC is optimised to help retain and resolve polar analytes. By use of high concentrations of organic solvent polar analytes partition with the stationary phase. Polar Retention Alternative Selectivity Rapid Equilibration Hydrophilic Interaction Chromatography (HILIC) works in a similar way to normal phase chromatography. A polar surface combined with a non-polar mobile phase, typically ACN, allows for partition of the polar analytes and hence retention and separation. Water is used in low concentration as the strong solvent in order to elute the compounds. Usually no more than 2%-3% water is needed in order to elute most analyte species. 8 k 4 2 Adenine Theobromine Uracil Toluene Nucleosides % organic :2 ACN: Water 9: ACN: Water FCN-53xx FCN-55xx FCN-57xx FCN-59xx 4 4 Replace xx - for.7µm - 3 for 3µm - 5 for 5µm :5 ACN: Water Tel: Tel:

11 HILIC DIOL Fortis HILIC Melamine Contamination Melamine has been adulterated into many products, but most importantly into baby milk in order to increase the apparent protein content. Due to its highly polar organic nature,,3,5-triazine structure, it can be very difficult to retain in HPLC. HILIC provides a simple method in order to quickly quantitate melamine. Column : Fortis HILIC x2.mm 3μ p/n : FHI-253 Mobile Phase: 9: ACN : 2mM NH 3 OAc Flow :.2ml/min Temp : 2 C Wavelength: 2nm Nucleosides Milk Blank Spiked Milk Retention of Polar Compounds Increased MS Sensitivity Alternate Selectivity Reduced Extraction (SPE) and Dry Down Times. Fortis HILIC DIOL (Hydrophilic Interaction Chromatography) is designed to aid in the separation and retention of very polar analytes. Extended retention is afforded by the partitioning, ion-exchange and hydrogen bonding that can occur on a HILIC stationary phase. Fortis HILIC DIOL can increase sensitivity in MS analysis and provide alternate selectivity to that achieved with reversed phase chemistries. Fortis HILIC DIOL is also available in.7µm particle size for UHPLC work. 5-Fluorouracil / Uracil Fortis HILIC DIOL is optimised not only to help retain and resolve polar analytes, but also to be complimentary in resolution to other Fortis phases. Hydrophilic Interaction Mode Strong Polar retention Rapid Equilibration Column : Fortis HILIC DIOL x2.mm 5μ p/n : FDI-255 Mobile Phase: 99: ACN : H 2 O Flow :.2ml/min Temp : 2 C Wavelength: 254nm. 5-Fluorouracil 2. Uracil.7μ,3μ, 5μ L2 Uracils HILIC DIOL 4% 38m2/g Fortis HILIC DIOL Nucleosides are typically difficult to retain due to the ribose or deoxyribose sugar that forms part of their structure. Fortis HILIC provides a good tool to retain and separate these polar analytes in simple mobile phase conditions. Column : Fortis HILIC 5x4.mm 5μ p/n : FHI-535 Mobile Phase: 95:5 ACN : mm NH 3 OAc Flow : ml/min Temp : 2 C Wavelength: 254nm Nucleosides. Uracil 2. Uridine 3. Cytosine 4. Guanosine Fortis HILIC DIOL FDI-23xx FDI-25xx FDI-27xx - Column Diameter 3. FDI-33xx FDI-35xx FDI-37xx - 4. FDI-53xx FDI-55xx FDI-57xx FDI-59xx Replace xx - for.7µm - 3 for 3µm - 5 for 5µm Fortis Amino Guards Length Column Diameter 2. DCDI-2xxG 4. DCDI-5xxG Fortis HILIC FHI-23xx FHI-25xx FHI-27xx - Column Diameter 3. FHI-33xx FHI-35xx FHI-37xx - 4. FHI-53xx FHI-55xx FHI-57xx FHI-59xx Fortis HILIC Guards Length Column Diameter 2. DCHI-2xxG 4. DCHI-5xxG Replace xx - for.7µm - 3 for 3µm - 5 for 5µm - for µm Tel: Tel:

12 Fortis Amino Column Reproducibility Retention of Polars Alternative Selectivity Highly stable ligand density Rapid Equilibration.7μ 3μ 5μ Amino 5% 2 /g m 8 3 L8 Robust Column Bondings Assured Peak Shapes 2% Lower Asymmetry Specification % Higher Efficiency Each Fortis HPLC column is tested using the industries most rigorous QC test, utilising basic analyte probes as well as neutral efficiency markers ensures that the column reproducibility is first class. Fortis columns are also subject to a 2% lower peak shape specification than other manufacturers columns. QA Test QC Test FNH Mobile Phase: 75 : 25 ACN : H2O Exceptional for Carbohydrate Alternative Selectivity Rapid Equilibration Flow :.ml/min Temp : 3 C Wavelength: RI. Ribose 2. Xylose 4. Glucose. Maltose x4.mm 5μ p/n: F8-555 By employing a QC mix that accurately probes silanol activity (the measure of good peak shape) the analyst can be assured of quality time and time again..ml/min Temp: 25 C Wavelength: 254nm Gains are also made in: 4 5. Sucrose Column: - Sample carry over - Increased Resolution - Increased Sensitivity 7 7. Lactose Phenol Ethylaniline 4. N,N-Dimethylaniline 5. Napthalene... QC HP5 Mobile Phase: :4 ACN:H2O. Uracil 2 3. Fructose Fortis stationary phases have been proven to exhibit excellent peak shapes and efficiency for the full range of analyte species. 22 Volts p/n : Fortis Amino 5x4.mm 5μ Column : Fortis Amino is optimised not only to help retain and resolve hydrogen bonding compounds, but to also be complimentary in resolution to other Fortis phases Carbohydrates Fortis Amino Fortis Amino allows the separation of compounds with reversed phase, normal phase or ion-exchange mechanisms. The Amino bonding is extremely rugged and reproducible to give stable baselines, retention times and selectivity. Amino columns are particularly suited for carbohydrate species. Fortis Amino is now also available in.7µm particle size for UHPLC work. Volts ¾ Colum ¾ p/n : ¾ Mobile ¾ Flow : ¾ Temp : ¾ λ:. Urac 2. Phe 3. 4-Et 4. N,N5. Nap Column Reproducibility Fortis Amino Column Diameter Fortis Amino Guards FNH-23xx FNH-25xx FNH-27xx - 3. FNH-33xx FNH-35xx FNH-37xx - 4. FNH-53xx FNH-55xx FNH-57xx FNH-59xx Replace xx - for.7µm - 3 for 3µm - 5 for 5µm Length Column Diameter 2. DCNH-2xxG 4. DCNH-5xxG Fortis columns are subject to tight specification using basic analytes in an unbuffered mobile phase system. If there were residual uncovered hydroxyl groups present then these basic probes would highlight this fact. Fortis Technologies unique bondings combined with the ultra pure silica matrix ensure that peak shapes and lifetime achieved are first class. Asymmetry Ethylaniline N,N-Dimethylaniline Napthalene Tel: Tel: columns 23

13 Capillaries Prep 5µm and µm particles High Loadability Optimised Packing Efficiency Narrow peak profile, High Efficiency and Resolution Fortis Prep columns are designed for high sample loading, high throughput applications. The optimised packed bed (OPB) process ensures excellent peak shapes and efficiency, whilst the lifetime of the column is increased. Capillaries Fortis capillaries are available in 75µm and 2µm i.d. with any phase chemistry and any particle size from the Fortis range. To find out more about the phase chemistry characteristics please refer to the full Product brochure: Column Diameter µm C75-5-xx-F8 C75--xx-F8 C75-5-xx-F8 C75-25-xx-F8 2µm C2-5-xx-F8 C2--xx-F8 C2-5-xx-F8 C2-25-xx-F8 Fortis Prep Replace xx - for.7µm - 3 for 3µm - 5 for 5µm BSA testing capillary Fortis stationary phases have been proven to provide sharp peaks shapes, critical for high resolution separations in small low dose formats. fmol/microlitre BSA 3µ 75µm x 5mm 4min gradient 3nl/min Improvements are made in: - Reduced sample carry over - Increased Resolution - Increased Sensitivity Relative Abundance Relative Abundance Time (min) Time (min).95 NL: 7.32E9 TIC MS BSAtest_ NL:.38E9 TIC MS BSAtest2_ Columns & Bulk Fortis Prep columns come in sizes from 3mm to 25mm in length and from mm in diameter all the way up to 5mm (2 i.d.). Pre-packed columns are advised for < 2 i.d. after this Bulk material can be supplied for those wishing to pack DAC (Dynamic Axial Compression) columns. If preparative columns are packed with the identical media to their analytical counterpart then the ability to scale up with the theoretical calculations will be accurate. - mm, 2.2mm and 3mm i.d. - 5µm and µm particles - g to multi Kg bulk available Contact us for more information on availability of prep options/bulk packings, or to discuss your application and the ability to scale up. Our technical experts will be happy to discuss your needs with you. Tel: Tel:

14 Filter & Guard Options Guard system for all 3µm, 5µm and µm phases Low volume in-line filters for LC and UHPLC Maintain chromatographic integrity Fortis Guards and filters are designed to ensure that erroneous materials do not find there way onto the more important and expensive analytical column. Guards are available in sizes to match all analytical and preparative column dimensions. Filters are particularly suitable for short fast LC/MS (Pace ) columns and UHPLC columns. Direct connect guard system for all 3µm, 5µm and µm phases Quick replacement cartridges - Highly Cost Effective 5µm Fortis Guard Cartridges DCGUA- Guard Cartridge Holder DCxx-45G/2 x4mm Fortis 5µm Guard pk 2 DCxx-45G/4 x4mm Fortis 5µm Guard pk 4 DCxx-25G/2 x2mm Fortis 5µm Guard pk 2 DCxx-25G/4 x2mm Fortis 5µm Guard pk 4 Replace xx 8 for PH for Fortis Diphenyl HO for Fortis H2o 8 for Fortis C8 CN for Fortis Cyano HI for Fortis HILIC Preparative guard system mm & 2.2mm Quick replacement cartridges - Highly Cost Effective - Reduced volume coupler available In-line Filter for all LC columns Low volume in-line filters Change over time is seconds not minutes 3µm Fortis Guard Cartridges DCGUA- Guard Cartridge Holder DCxx-43G/2 x4mm Fortis 3µm Guard pk 2 DCxx-43G/4 x4mm Fortis 3µm Guard pk 4 DCxx-23G/2 x2mm Fortis 3µm Guard pk 2 DCxx-23G/4 x2mm Fortis 3µm Guard pk 4 Fortis in-line filters are fingertight direct connect design, fitting in between the column and the conventional peek fitting to filter out particulate matter, it contains low dead volume and pressure. In-line filters are ideal for very short fast columns such as Fortis Pace LC/MS columns where extra packed bed from a guard would be detrimental. In-line filters are also available in UHPLC format, capable of withstanding the elevated pressures involved. Part number tables F8-2xx F8-22xx F8-23xx F8-25xx F8-27xx - Column Diameter 3. - F8-32xx F8-33xx F8-35xx F8-37xx F8-52xx F8-53xx F8-55xx F8-57xx F8-59xx Replace xx - for.7µm - 2 for 2.5µm - 3 for 3µm - 5 for 5µm - for µm Fortis Diphenyl FPH-2xx FPH-22xx FPH-23xx FPH-25xx FPH-27xx - Column Diameter 3. - FPH-32xx FPH-33xx FPH-35xx FPH-37xx FPH-52xx FPH-53xx FPH-55xx FPH-57xx FPH-59xx Replace xx - for.7µm - 2 for 2.5µm - 3 for 3µm - 5 for 5µm - for µm Fortis H2o FHO-2xx FHO-22xx FHO-23xx FHO-25xx FHO-27xx - Column Diameter 3. - FHO-32xx FHO-33xx FHO-35xx FHO-37xx FHO-52xx FHO-53xx FHO-55xx FHO-57xx FHO-59xx Replace xx - for.7µm - 3 for 3µm - 5 for 5µm Fortis C F8-2xx F8-22xx F8-23xx F8-25xx F8-27xx - Column Diameter 3. - F8-32xx F8-33xx F8-35xx F8-37xx F8-52xx F8-53xx F8-55xx F8-57xx F8-59xx Replace xx - for.7µm - 3 for 3µm - 5 for 5µm Fortis Cyano FCN-2xx FCN-22xx FCN-23xx FCN-25xx FCN-27xx - Column Diameter 3. - FCN-32xx FCN-33xx FCN-35xx FCN-37xx FCN-52xx FCN-53xx FCN-55xx FCN-57xx FCN-59xx Replace xx - for.7µm - 3 for 3µm - 5 for 5µm Fortis HILIC FHI-2xx FHI-22xx FHI-23xx FHI-25xx FHI-27xx - Column Diameter 3. FHI-32xx FHI-33xx FHI-35xx FHI-37xx - 4. FHI-52xx FHI-53xx FHI-55xx FHI-57xx FHI-59xx Replace xx - for.7µm - 3 for 3µm - 5 for 5µm - for µm Fortis HILIC DIOL FDI-2xx FDI-22xx FDI-23xx FDI-25xx FDI-27xx - Filter for all UHPLC columns No backpressure increase Increase lifetime of UHPLC columns Low volume in-line filter Change over time is seconds not minutes Analytical In-line Filters 2-SAV5 2µm In-line filter pk 5 2-SAV 2µm In-line filter pk UHPLC In-line Filters UHPSAV2 UHPLC In-line filter pk 2 UHPSAV4 UHPLC In-line filter pk 4 Column Diameter 3. FDI-32xx FDI-33xx FDI-35xx FDI-37xx - 4. FDI-52xx FDI-53xx FDI-55xx FDI-57xx FDI-59xx Replace xx - for.7µm - 3 for 3µm - 5 for 5µm - for µm Fortis Amino FNH-2xx FNH-22xx FNH-23xx FNH-25xx FNH-27xx - Column Diameter 3. FNH-32xx FNH-33xx FNH-35xx FNH-37xx - 4. FNH-52xx FNH-53xx FNH-55xx FNH-57xx FNH-59xx Replace xx - for.7µm - 3 for 3µm - 5 for 5µm - for µm Tel: Tel:

15 Applications Compound Use Column,3-Dimethyluric acid a Hydroxyprogesterone Steroid Fortis H2o SpeedCore Diphenyl a-hydroxyprogesterone Steroid Fortis Cyano 7 a Hydroxyprogesterone Steroid Fortis H2o 7-Hydroxyprogesterone Hormone -Hydroxy-midazolam Anxiolytic 2,4-D Herbicide Fortis Cyano 2,4-DB Herbicide Fortis Cyano 2,4-DCP Herbicide 2,4-DP Herbicide Fortis Cyano 2,-Dimethylphenol SpeedCore C8 2,-Dinitrotoluene Explosives Fortis Cyano 2-Hydroxybenzoic acid Positional Isomers Fortis Diphenyl 2-Hydroxyestradiol Positional Isomers Fortis Diphenyl 2-Nitroaniline Explosives Fortis Cyano 3,4-Dimethylphenol 3,5-Dimethylphenol SpeedCore C8 SpeedCore C8 3-hydroxyanabsinthin Sesquiterpene Lactones 3-Hydroxybenzoic acid Positional Isomers Fortis Diphenyl 3-Methoxytyramine catecholamine Fortis HILIC 3-Nitrobenzoic acid 3-Octanon Fragrence 4-Ethylaniline 4-Hydroxybenzoic acid Positional Isomers Fortis Diphenyl 4-Hydroxyestradiol Positional Isomers Fortis Diphenyl 4-Nitroaniline Explosives Fortis Cyano 5-Fluorouracil anticarcinogen SpeedCore HILIC 5-HIAA Catecholamines Fortis H2o -monacetylmorphine Drugs of Abuse 7-Aminoclonazepam Hypnotic 7-Aminoflunitrazepam Benzodiazepines 7-Aminonitrazepam Anxiolytic Absinthin Sesquiterpene Lactones Acetaminophen Flu Relief Acetic acid Ear Infections Adenine Polars Fortis HILIC ALA Amino Acids Aldehydes Aldehydes Aliskiren Renin Inhibitor SpeedCore C8 Terpineol Plant Hormone Alprazolam Anxiolytic Amiloride Diuretic Amitriptyline Antidepressant Amoxicillin Antibiotic Amphetamine Drugs of Abuse Amprenavir HIV Drugs Anabsin Sesquiterpene Lactones Anabsinthin Sesquiterpene Lactones Angiotensin I Peptide FortisBIO C4 Angiotensin II Peptide FortisBIO C8 Apigenin Natural Dyes Apomyoglobin Protein FortisBIO C8 ARG Amino Acids Artemisetin Sesquiterpene Lactones Ascisic acid Plant Hormone Ascorbic acid Vitamins Fortis HILIC ASP Amino Acids Atazanavir HIV Drugs Atenolol Beta Blocker Fortis H2o Atorvastatin Statins Azithromycin Antibiotic Banvel Herbicide Bendroflumethiazide Thiazide Diuretic Fortis H2o Benoquinone acetic acid Fortis H2o Benzene Alkyl Benzenes Benzoylecgonine Drugs of Abuse Benzyladenine Plant Hormone Bromazepam Benzodiazepines Butylbenzene Alkyl Benzenes Caffeine Alkaloid SpeedCore Diphenyl Campher Fragrance candesartan cilexetil Hypertension Casein Protein FortisBIO C8 Casein Tryptic Digest Catechol FortisBIO C8 SpeedCore C8 Cefachlor Antibiotic Cefadroxil Antibiotic Cefalexin Antibiotic Cefradine Antibiotic Chloramphenicol Antibiotic Fortis H2o Cineol Fragrance Ciprofloxacin Antibiotic Fortis Diphenyl Citalopram Antidepressant Clonaepam Hypnotic Clopidogrel Hydrogen SO 4 Antiplatelet Fortis C8 Clozapine Drugs of Abuse CMPP Herbicide Fortis Cyano co-amoxiclav Antibiotic co-codamol Pain Relief Cortisone Anti-Inflammatory CYS-CYS Amino Acids Cytochrome C Protein FortisBIO C8 Cytosine Nuclosides Fortis HILIC Applications D3-Digitoxin Cardiac glycosides Dalbavancin Antibiotic Fortis Diphenyl Demoxepam Benzodiazepines Desmethyldiazepam Anxiolytic Dexamethasone Ear Infections Diamorphine opioid analgesic Fortis H2o Dianette Alkaloid Diazepam Anti Anxiety Diclofenac Sodium Painkiller Tel: Tel: Diethylaniline Digitoxin Cardiac glycosides Dihydroquinidine antiarrhythmic Fortis Diphenyl Diltiazem High Blood Pressure Fortis H2o Dimethylaniline Diphenhydramine Antihistamine d-metafetamine Drugs of Abuse DOPAC Catecholamines Fortis H2o Dopamine catecholamine Fortis HILIC Doxazosin alpha-blocker Fortis Diphenyl Entecavir Antiviral Fortis Diphenyl Epinephrine catecholamine Fortis HILIC Epiyangambin Sesquiterpene Lactones Erythromycin Erythromycin Fortis HILIC Estradiol Valerate SpeedCore Diphenyl Estradiols Estradiols Fenuron Flucloxacillin Antibiotic Flunitrazepam Anxiolytic Fluoruracil Polars Fortis HILIC Fluoxetine Antidepressant Folic Acid Vitamin Fortis H2o Fructose monosaccharide Fortis Amino Gabapentin Epilepsy Gibberellin acid Plant Hormone Gliclazide Diabetes GLU Amino Acids Glucose monosaccharide Fortis Amino GLY Amino Acids GLY-TYR Peptide FortisBIO C8 Guanosine Nuclosides Fortis HILIC Haloperidol Antipsychotic Heptylbenzene Alkyl Benzenes Hexylbenzene Alkyl Benzenes HIS Amino Acids Holo-Transferrin Protein FortisBIO C8 Homogentisic acid Fortis H2o Human Growth Hormone Peptide Hormone FortisBIO C8 Hydroxy-2-acetate Steroid Fortis Cyano Hydroxyphenylacetic acid Fortis H2o Hydroxyphenylpyruvic acid Fortis H2o Hydroxytisone-2-acetate Steroid Fortis H2o Ibuprofen Painkiller ILE Amino Acids Indol-3-yl-acetate Plant Hormone Insulin Peptide FortisBIO C4 Irbesartan Angiotensin II antagonist Isoascorbic acid Vitamins Fortis HILIC Isonicatinamide Positional Isomers Fortis Diphenyl Ketopelenolide Sesquiterpene Lactones Kinetin Plant Hormone Lactose disaccharide Fortis Amino Lamotrigine Epilepsy Fortis C8 Lanalool Fragrance Lanandulyl acetate Lansoprazole Stomach Ulcers Lavandulol LEU Amino Acids LEU-Enkephalin Peptide FortisBIO C8 Levocetirizine Antihistamine Fortis H2o Lidocaine Irregular Heartbeats Limonen Fragrance Linalyl Acetate Fragrance Lopinavir HIV Drugs Loratadine Antihistamine Lorazepam Anti Anxiety Fortis Diphenyl LSD Drugs of Abuse Luteolin Natural Dyes LYS Amino Acids Maltose disaccharide Fortis Amino MCPA Agrochemicals MCPB Weed Control Fortis Cyano m-cresol SpeedCore C8 MDA Drugs of Abuse MDEA Drugs of Abuse MDMA (Ecstasy) Drugs of Abuse Melamine Fortis HILIC MET Amino Acids Metanephrine catecholamine Fortis HILIC MET-Enkephalin Peptide FortisBIO C8 Methamphetamine Drugs of Abuse Methyl Melonic acid Organic acids Fortis H2o Methylbenzoate Midazolam Anxiolytic Mirtazapine Antidepressant Morphine Drugs of Abuse N,N-Dimethylaniline QC Test Naphthalene QC Test Nelfinavir HIV Drugs

16 Applications Neomycin Sulphate Ear Infections Nicotinamide Positional Isomers Fortis Diphenyl Nicotinic acid Vitamins Fortis HILIC Nitosininone Fortis H2o Nitrazepam Anxiolytic Nitrobenzene Explosives Fortis Cyano Nogestrel SpeedCore Diphenyl Nordiazepam Drugs of Abuse Normetanephrine catecholamine Fortis HILIC Norpinephrine catecholamine Fortis HILIC Nortriptyline Tricyclic Antidepressants o-cresol SpeedCore C8 -Dalbavancin Antibiotic Fortis Diphenyl Olanzapine antipsychotic SpeedCore C8 Omeprazole Stomach Ulcers Oseltamivir Antiviral Oxazepam Hypnotic PAH PAH EPA Paracetamol Flu Relief Paroxetine Antidepressant Fortis H2o PCOC Weed Control Fortis Cyano p-cresol SpeedCore C8 Pentylbenzene Alkyl Benzenes Pesticides KFDA83-59 Pesticides PHE Amino Acids Phenol SpeedCore C8 Phenoxymethylpenicillin Antibiotic Phenylephrine Flu Relief Pheophorbide Pheophytin PK95 PET Tracer Fortis Diphenyl PK95 Dechlorinated PET Tracer Fortis Diphenyl Prednisolone Steroid Fortis H2o Prednisone Steroid Fortis H2o Premarin Estrogens SpeedCore HILIC PRO Amino Acids Procaine Anestetic Prochlorperazine Maleate phenothiazine antipsychotics Fortis Diphenyl Progesterone Steroid Fortis H2o Proguanil Anti Malarial Fortis Diphenyl Promethazine theoclate Nausea Propylbenzene Alkyl Benzenes Protriptyline Antidepressant Pyrazoline Pyridine Pyridoxine Polars Fortis HILIC Pyropheophytin Quetiapine antipsychotic SpeedCore C8 Quinidine antiarrhythmic Fortis Diphenyl Raloxifene Glucoronides treat osteoporosis Rasagiline Parkinsons SpeedCore C8 Resorcinol SpeedCore C8 Riboflavin Vitamins Fortis HILIC Ribonuclease A Protein FortisBIO C8 Ribose monosaccharide Fortis Amino Ritonavir HIV Drugs Rosuvastatin Statins Sequinavir HIV Drugs SER Amino Acids Serotonin Catecholamines Fortis H2o Sesartemin Sesquiterpene Lactones Simvastatin High Blood Pressure Fortis H2o Sotalol Beta Blocker Succinic acid Organic acids Fortis H2o Sucrose disaccharide Fortis Amino Sulfamerazine Sulfa Drugs Sulfamethoxazole Sulfa Drugs Sulfathiazole Sulfa Drugs Sumatriptan UniverSil HS C8 Telmisartan Hypertension Fortis C8 Temazepam Anti Anxiety Tenofovir HIV Drugs Fortis H2o Terpinen 4 ol Fragrance Testosterone Hormone Theobromine SpeedCore Diphenyl Theophylline Alkaloid THR Amino Acids Thymidine (IS) HIV Drugs Fortis H2o Tiotropium bromide bronchodilator Toluene Polars Fortis HILIC Tramadol Opioid Painkiller Trimipramine Antidepressant TYR Amino Acids Tyrosine Amino Acids Fortis H2o Uracil Nuclosides Fortis HILIC Uridine Nuclosides Fortis HILIC VAL Amino Acids Valproate Semisodium Manic Depression Fortis C8 VAL-TYR-VAL Peptide FortisBIO C8 Verapamil Irregular Heartbeats Vitamin C Vitamins Fortis HILIC Warfarin anticoagulant Fortis H2o Xylose monosaccharide Fortis Amino Zolpidem Hypnotic Zopiclone Hypnotic Fortis Phase Characteristics Particle Size Surface Area (m 2 /g) %C Pore Size ph range USP.7µ 3µ 5µ µ L Fortis H2o.7µ 3µ 5µ L Fortis Diphenyl.7µ 3µ 5µ µ L Fortis C8.7µ 3µ 5µ µ L7 Fortis HILIC.7µ 3µ 5µ µ 38 N/A 2-8 L3 Fortis HILIC Diol.7µ 3µ 5µ L2 Fortis Cyano.7µ 3µ 5µ L Fortis Amino.7µ 3µ 5µ L8 Particle Size Particle Size Surface Area (m 2 /g) Surface Area (m 2 /g) %C Pore Size ph range USP FortisBIO C8.7µ 5µ L FortisBIO C4.7µ 5µ L2 %C Pore Size ph range USP SpeedCore C8 2.µ L SpeedCore Diphenyl 2.µ L SpeedCore PFP (PentaFluoroPhenyl) 2.µ L43 SpeedCore HILIC 2.µ 4 N/A L3 Tel: Tel:

17 WORLDWIDE AVAILABILITY Fortis products are available worldwide. For the distributor in your country, contact Fortis international Sales Office, UK by telephone, fax or 45 Coalbrookdale Road Clayhill Industrial Park Neston Cheshire, UK CH4 3UG t: f: e: info@fortis-technologies.com Austria Bangladesh Brazil Canada China Columbia Czech Republic Ecuador Egypt France Germany Greece Holland Hong Kong Hungary India Ireland Israel Italy Japan Korea Malaysia Mexico Netherlands Norway Puerto Rico Poland Portugal Romania Russia Singapore South Africa Spain Sweden Switzerland Taiwan Thailand Turkey USA For technical support or applications contact : technicalsupport@fortis-technologies.com For more information VISIT : Fortis Diphenyl, Fortis H2o, Fortis C8, Fortis Cyano, Fortis HILIC, Fortis Pace are registered trademarks of Technologies Ltd. Sunfire, Xbridge, Acquity BEH, UPLC, Atlantis and Xterra are registered trademarks of Waters Corporation. Luna, Gemini,Kinetex and Synergi are registered trademarks of Phenomenex. Zorbax Eclipse XDB and Zorbax SB-C8 are registered trademarks of Agilent Technologies. Inertsil is a registered trademark of GL Sciences. ACE is a registered trademark of ACT Fortis is not associated with these companies. Comparative separations may not be representative of all applications. All columns are original manufacturers own. 24 Fortis Technologies Ltd. All rights reserved.

Applications. Column Reproducibility. Casein Tryptic Digest. QC Test. Antimalarial. Antipsychotic. Column Reproducibility 7

Applications. Column Reproducibility. Casein Tryptic Digest. QC Test. Antimalarial. Antipsychotic. Column Reproducibility 7 Column Reproducibility Robust Column Bondings Assured Peak Shapes % Lower Asymmetry Specification % Higher Efficiency Fortis HPLC columns are tested using the industries most rigorous QC test, utilising

More information

1.7µm Fortis C18 UHPLC Columns

1.7µm Fortis C18 UHPLC Columns Strength in Technology.7µm Fortis C8 Columns Ultra High Pressure Chromatography Increase Efficiency Increase Speed Improve Resolution Greater Sensitivity Wider Linear flow rate range .7µm Columns - 8m/g

More information

1.7µm Fortis UHPLC Columns

1.7µm Fortis UHPLC Columns Strength in Technology.7µm Fortis Columns NEW Phase Chemistries - Fortis Ho (polar endcapped) - Fortis Amino - Fortis HILIC Diol Ultra High Pressure Chromatography 8 Chemistry Choices Increase Efficiency

More information

Strength in Technology

Strength in Technology Strength in Technology Fortis C8 Excellent Peak Shapes Superb Quantitation ph Range - Fully Scalable 3,5,0μ C8 7% Fortis C8 is designed to provide characteristics which will aid in increased productivity

More information

1.7 m Fortis UHPLC Columns

1.7 m Fortis UHPLC Columns Strength in Technology 1.7 m Fortis Columns Ultra High Pressure Chromatography Improve your Performance 8 Chemistry Choices Increase Efficiency Increase Speed Improve Resolution Greater Sensitivity Lower

More information

3µm Fortis C18. Fortis 2.1µm. Increased Efficiency. Scalability and Sensitivity

3µm Fortis C18. Fortis 2.1µm. Increased Efficiency. Scalability and Sensitivity Fortis 2.1µm 2.1µm Fortis C18 (2) High Efficiency Robust Particles Operate to 15,000psi Fully Scalable to analytical and prep size Fortis 2.1µm particles are designed to provide characteristics, which

More information

viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis

viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis [ viridis columns ] viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis Supercritical Fluid Chromatography (SFC)

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS HALO and HALO- Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG PE, UK Tel: + (0)8 90 0 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns Product Bulletin HPLC Columns ACE LC/MS and Rapid Analysis HPLC Columns 0 mm, 30 mm, 35 mm and 50 mm column lengths.0,., 3.0, 4.0 and 4.6 mm column diameters Configured for High Sample Throughput Specially

More information

Part 2. Overview of HPLC Media

Part 2. Overview of HPLC Media Part 1. General Chromatographic Theory Part 2. Overview of HPLC Media Part 3. The Role of the Mobile Phase in Selectivity Part 4. Column Care and Use 1 HPLC Particle Technology Core-Shell Particle Fully

More information

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability ACE SuperC8 TM Ultra-Inert UHPLC and HPLC s with Extended ph Stability Exploit selectivity at low, intermediate and high ph Use with LC/MS compatible buffers between ph.. High efficiency µm, µm, µm and

More information

ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability ACE Excel SuperC8 TM Ultra-Inert UHPLC and HPLC s with Extended ph Stability Exploit selectivity at low, intermediate and high ph Use with LC/MS-compatible buffers between ph.. High efficiency µm, µm,

More information

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development ACE C8-Amide For increased polar retention and alternative selectivity Alternative selectivity for method development Improved separations with polar, acidic, basic and phenolic compounds High efficiency

More information

Reversed Phase Solvents

Reversed Phase Solvents Part 1. General Chromatographic Theory Part 2. verview of HPLC Media Part 3. The Role of the Mobile Phase in Selectivity Part 4. Column Care and Use Reversed Phase Solvents 2 Solvents for RP Chromatography

More information

Too Polar for Reversed Phase What Do You Do?

Too Polar for Reversed Phase What Do You Do? Too Polar for Reversed Phase What Do You Do? June 20, 2013 Mark Powell Columns and Consumables Technical Support Page 1 C8 or C18 Doesn t Always Do the Job Typical reversed phase conditions involve water/buffer

More information

Hypersil BDS Columns TG 01-05

Hypersil BDS Columns TG 01-05 TG 0-0 Hypersil BDS Columns Introduction Hypersil BDS columns have gained a reputation over the years as one of the most robust, reproducible and reliable HPLC column brands available. This Technical Guide

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS SeQuant ZIC-HILIC Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability ACE SuperC8 TM Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability Exploit selectivity at low, intermediate and high ph Use with LC/MS compatible buffers between ph.. High efficiency µm, µm,

More information

HPLC UHPLC Columns. Dikma Technologies Inc.

HPLC UHPLC Columns. Dikma Technologies Inc. Technologies Inc. About HPLC UHPLC Columns has over years of R&D experience in HPLC / UHPLC columns. HPLC / UHPLC columns have been widely used by pharmaceutical manufacturers. We offer columns of ultimate

More information

Separation of Structurally Similar Steroids on HALO C18 and PFP

Separation of Structurally Similar Steroids on HALO C18 and PFP Application Note: 047-STR Separation of Structurally Similar Steroids on HALO C8 and PFP, 4 G009 HALO C8 HALO PFP 4. Prednisone. Cortisone. Prednisolone 4. Hydrocortisone 0 4 5 6 7 Columns: 4.6 x 00 mm,

More information

Method Development Kits

Method Development Kits Method Development Kits sales representative for ordering information or contact...77 Method Development Kits First column choice for Pharma Development USP L C Method Development Kits Maximize retention

More information

LC and LC/MS Column Selection Flow Chart

LC and LC/MS Column Selection Flow Chart LC and LC/MS Column Selection Flow Chart To use the column selection diagram below, simply follow the path for your analyte and mobile phase. At the far right, follow your final column selection to the

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS SIELC Primesep Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)8 90 660 Fax: +44 (0)8 9 484 Email: sales@hichrom.co.uk

More information

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules columns Acclaim Mixed-Mode WCX- for Separating Basic Molecules The Acclaim Mixed-Mode WCX- is a novel, high-efficiency, silica-based column specially designed for separating various basic analytes. This

More information

Bringing uhplc Performance to the Separation of Peptides

Bringing uhplc Performance to the Separation of Peptides P e p t i d e E S - C 1 8 U H P L C C o l u m n s Bringing uhplc Performance to the Separation of Peptides Compatible with UHPLC and conventional HPLC equipment. Sumpfstr. 3, CH-6300 Zug; Fax: 041 748

More information

ANALYSIS OF BASIC COMPOUNDS

ANALYSIS OF BASIC COMPOUNDS COMPARISON OF Fully AND Superficially POROUS PARTICLE COLUMNS FOR THE ANALYSIS OF BASIC COMPOUNDS Kenneth J. Fountain, Jane Xu, Zhe Yin, Pamela C. Iraneta, Diane M. Diehl Waters Corporation GOAL Compare

More information

State-of-the-art C18 HPLC Columns

State-of-the-art C18 HPLC Columns An HPLC GL Sciences Newest and Most Advanced ODS Phase-New For 00 State-of-the-art C HPLC s Improved Peak Shapes and Heights Enhancing Sensitivity High Resolution Fast Equilibration Compatible with 00%

More information

Alltech Alltima HP Introduction

Alltech Alltima HP Introduction Alltech Introduction High-Stability, High-Purity, High-Performance, Low-Bleed Columns for Demanding Applications Better Peak Symmetry high-purity silica eliminates peak tailing problems Long Column Life

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Vydac. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Vydac. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS Vydac Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

Setting the Standard for ph Method Development

Setting the Standard for ph Method Development U.S. Patent o. 7, 5, 7 Setting the Standard for ph Method Development ugged reversed phase HPLC columns that offer extended lifetime at extreme ph conditions and excellent stability for reproducible, high

More information

ACE Ultra Inert Base Deactivated HPLC Columns

ACE Ultra Inert Base Deactivated HPLC Columns ACE Ultra Inert Base Deactivated HPLC Columns Contents Page ACE HPLC Columns...- Independent Comparison of HPLC Columns #... Independent Comparison of HPLC Columns #... ACE 00Å HPLC Columns Specifications...-

More information

Gemini. Second-Generation TWIN-NX Technology. TWIN (Two-In-One) Technology. U.S. Patent No. 7, 563, 367 Setting the Standard for ph Method Development

Gemini. Second-Generation TWIN-NX Technology. TWIN (Two-In-One) Technology. U.S. Patent No. 7, 563, 367 Setting the Standard for ph Method Development U.S. Patent o. 7, 5, 7 Setting the Standard for ph Method Development ugged reversed phase HPLC columns that offer extended lifetime at extreme ph conditions and excellent stability for reproducible, high

More information

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

Thermo Scientific Accucore XL HPLC Columns. Technical Manual Thermo Scientific Accucore XL HPLC Columns Technical Manual Thermo Scientific Accucore XL HPLC Columns Based on Core Enhanced Technology using µm solid core particles, Accucore XL HPLC columns allow users

More information

H P L C C O L U M N S

H P L C C O L U M N S H P L C C O L U M N S New, HxSil TM C8 and C8 HPLC Columns A Word about HPLC Columns For over 0 years Hamilton HPLC columns have been solving problems no other columns could. Now we have introduced HxSil

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS Zorbax Catalogue 9 1 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)118 930 3660 Fax: +44 (0)118 932 3484 Email:

More information

Your Reversed Phase Method

Your Reversed Phase Method PLC Columns for Your Reversed Phase Method Balanced Non-Polar & Polar Selectivity Strong Non-Polar & Polar Selectivity Strong Polar & Aromatic Selectivity Unique Isomeric & alogenated Selectivity Robust

More information

InertSustainSwift C8

InertSustainSwift C8 HPLC, LC/MS Columns InertSustainSwift TM C8 New! InertSustainSwift C8 is an octyl group (C8) bonded column offering the same extreme inertness to any type of compounds just like InertSustainSwift C8, which

More information

New Product Update. HPLC Columns

New Product Update. HPLC Columns New Product Update HPLC Columns ZORBAX MicroBore HPLC Columns ZORBAX Extend-C18 Columns ZORBAX Bonus-RP Columns Inertsil ODS-2 Cartridge Columns ZORBAX Carbohydrate Analysis Columns ZORBAX Eclipse dsdna

More information

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint An important new column in the Inertsil series Bonded-Phase Structure Perfect balance of retention for both polar

More information

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times The Secrets of Rapid HPLC Method Development Choosing Columns for Rapid Method Development and Short Analysis Times Rapid Analysis Is More Than Run Time It is developing a method to meet a goal and developing

More information

How proteins separate on reverse-phase HPLC

How proteins separate on reverse-phase HPLC 1 Reverse Phase How proteins separate on reverse-phase HPLC RP chromatography separates proteins through the interaction of the hydrophobic foot of the protein with a nonpolar surface of the particle RP

More information

( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k

( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k Selectivity Choices in Reversed-Phase Fast LC Luisa Pereira, Monica Dolci, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20543 Key Words Accucore, Hypersil GOLD, Syncronis, Column Chemistry,

More information

Put the. C18 aside. and take a look... Reasons. to try the. NEW Gemini C6-Phenyl

Put the. C18 aside. and take a look... Reasons. to try the. NEW Gemini C6-Phenyl Put the C18 aside and take a look... 6 Reasons to try the EW Gemini Reason #6 ALTERATE SELECTIVITY to your C18 Column Adding to your method development options, Gemini offers additional polar and aromatic

More information

Gemini-NX Performance paired with Axia Technology

Gemini-NX Performance paired with Axia Technology Si Si Si Si Si Si Si C Si Si Si Si Si Gemini-NX Performance paired with Axia Technology Gemini -NX Axia Packed Technology Improves Yield, Throughput, and Column Lifetime Ideal Purification Platform While

More information

ultimate efficiency unleashed [ Cortecs 1.6 µm columns ]

ultimate efficiency unleashed [ Cortecs 1.6 µm columns ] ultimate efficiency unleashed [ Cortecs columns ] [ CORTECS UPLC COLUMNS ] A SUB--µm SOLID-CORE PARTICLE COLUMN THAT LIVES UP TO ITS POTENTIAL. C 8 + C 8 HILIC SOLID-CORE PARTICLE COLUMNS THAT DELIVER

More information

Peptide and protein analysis by capillary HPLC Optimization of chromatographic and instrument parameters. Application. Angelika Gratzfeld-Huesgen

Peptide and protein analysis by capillary HPLC Optimization of chromatographic and instrument parameters. Application. Angelika Gratzfeld-Huesgen Peptide and protein analysis by capillary HPLC Optimization of chromatographic and instrument parameters Application Angelika Gratzfeld-Huesgen Abstract This application has been verified using an Agilent

More information

Choosing Columns and Conditions for the Best Peak Shape

Choosing Columns and Conditions for the Best Peak Shape Choosing Columns and Conditions for the Best Peak Shape What is Good Peak Shape and Why is it Important? Good peak shape can be defined as a symmetrical or gaussian peak and poor peak shape can include

More information

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS penta-hilic UHPLC COLUMNS penta-hilic Highly retentive, proprietary penta-hydroxy-ligand Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and

More information

ColumnsAcclaim PolarAdvantage II (PA2) HPLC Columns

ColumnsAcclaim PolarAdvantage II (PA2) HPLC Columns ColumnsAcclaim PolarAdvantage II (PA) HPLC Columns A Unique and Complementary Alternative to Conventional C8.8 Column: Acclaim PA, µm Peaks: ( ppm each) Dimensions:. mm. Maleate Mobile Phase: MeOH/.% NH

More information

A Look at Agilent HPLC Columns Choices

A Look at Agilent HPLC Columns Choices A Look at Agilent HPLC Columns Choices Brno & Prague, May 29-30 2018 Giorgio Ferlat IDO Product Specialist Chemistries and Consumable 1 Considerating Column Properties for Column Selection Silica Particle

More information

Setting the Standard for ph Method Development

Setting the Standard for ph Method Development U.S. Patent o. 7, 56, 67 Setting the Standard for ph Method Development ugged reversed phase HPLC columns that offer extended lifetime at extreme ph conditions and excellent stability for reproducible,

More information

Fluophase and Fluofix Columns

Fluophase and Fluofix Columns TG 0-0 Fluophase and Columns Introduction Fluorinated packings exhibit extra retention and selectivity for compounds that have fluorine and chlorine substituents. They also exhibit shape selectivity for

More information

ACE C18-PFP. Hydrophobic and pentafluorophenyl mixed mode interaction. High efficiency 2µm, 3µm, 5µm and 10µm particles for UHPLC and HPLC

ACE C18-PFP. Hydrophobic and pentafluorophenyl mixed mode interaction. High efficiency 2µm, 3µm, 5µm and 10µm particles for UHPLC and HPLC ACE C-PFP A C bonded phase with unique selectivity F F F F F Guaranteed reproducibility Exceptional bonded phase stability Hydrophobic and pentafluorophenyl mixed mode interaction High efficiency µm, µm,

More information

The Evolving HPLC Column Packings

The Evolving HPLC Column Packings The Evolving HPLC Column Packings GL Sciences has been steadily supplying with columns from Inertsil ODS, first-generation to InertSustain series, integration of state-ofthe-art technologies, and has established

More information

The Standard for ph Method Development

The Standard for ph Method Development The Standard for ph Method Development High Efficiency Excellent Lifetime ph Stable - www.phenomenex.com/gemini U.S. Patent No.,, Setting the Standard for ph Method Development Gemini columns are rugged

More information

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns have: the highest plate number versus any other 5-micron

More information

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules www.interchim.com www.blog.interchim.com www.forum.interchim.com www.facebook.com/interchim

More information

BETASIL Columns TG Å high purity silica

BETASIL Columns TG Å high purity silica BETASIL Columns TG0-0 00Å high purity silica Technical Guide BETASIL Columns Introduction 00Å high purity silica High surface area and phase loading Designed for small molecules Type B silica gives good

More information

Proteins: Characteristics and Properties of Amino Acids

Proteins: Characteristics and Properties of Amino Acids SBI4U:Biochemistry Macromolecules Eachaminoacidhasatleastoneamineandoneacidfunctionalgroupasthe nameimplies.thedifferentpropertiesresultfromvariationsinthestructuresof differentrgroups.thergroupisoftenreferredtoastheaminoacidsidechain.

More information

[ Care and Use Manual ]

[ Care and Use Manual ] Oasis HLB DISKS I. Introduction Oasis HLB is a Hydrophilic-Lipophilic-Balanced, water-wettable, reversed-phase sorbent for all your SPE needs. It is made from a specific ratio of two monomers, the hydrophilic

More information

STUDY OF LOADABILITY AND SELECTIVITY OF PHARMACEUTICAL COMPOUNDS ON RPLC COLUMNS

STUDY OF LOADABILITY AND SELECTIVITY OF PHARMACEUTICAL COMPOUNDS ON RPLC COLUMNS STUDY OF LOADABILITY AND SELECTIVITY OF PHARMACEUTICAL COMPOUNDS ON RPLC COLUMNS Fang Xia, Jie Y. Cavanaugh, Uwe Neue, Jeffrey R. Mazzeo, Diane M. Diehl Waters Corporation, Milford, MA USA OVERVIEW- INTRODUCTION-

More information

Packings for HPLC. Packings for HPLC

Packings for HPLC. Packings for HPLC Summary of packings for HPLC In analytical HPLC, packings with particle sizes of 3 to 10 µm are preferred. For preparative separation tasks, also particles with diameters larger than 10 µm are applied.

More information

LC Columns with Liquid Separation Cell Technology

LC Columns with Liquid Separation Cell Technology Obelisc LC Columns with Liquid Separation Cell Technology Obelisc HPLC Columns - Liquid Separation Cell Technology Introduction Obelisc HPLC columns are the latest, innovative columns from SIELC Technologies,

More information

AN HPLC COLUMN InertSustain C1 AN HPLC COLUMN InertSustain C1 Inertsil continues to evolve to InertSustain Physical Properties

AN HPLC COLUMN InertSustain C1 AN HPLC COLUMN InertSustain C1 Inertsil continues to evolve to InertSustain Physical Properties AN HPLC COLUMN TM InertSustain C8 AN HPLC COLUMN InertSustain TM C8 Inertsil continues to evolve to InertSustain Physical Properties Silica : Newly Developed Silica Gel Particle Size : m, m, m Surface

More information

Optimisil HPLC & UPLC Column catalogue

Optimisil HPLC & UPLC Column catalogue Optimisil HPLC & UPLC Column catalogue Analytical Hub Plot No: 37, P & T Colony, Vikrampuri, Secunderabad 500009 Tel: 040-64621313, Mobile: +91 7799931313 Website: www.analyticalhub.com email: contact@analyticalhub.com

More information

A Plausible Model Correlates Prebiotic Peptide Synthesis with. Primordial Genetic Code

A Plausible Model Correlates Prebiotic Peptide Synthesis with. Primordial Genetic Code Electronic Supplementary Material (ESI) for ChemComm. This journal is The Royal Society of Chemistry 2018 A Plausible Model Correlates Prebiotic Peptide Synthesis with Primordial Genetic Code Jianxi Ying,

More information

William E. Barber, Ph.D. Applications Chemist October

William E. Barber, Ph.D. Applications Chemist October William E. Barber, Ph.D. Applications Chemist ctober 0 00 Secrets of Good Peak Shape in HPLC Time: :00 p.m. CET Telephone Number: + 44 0 76 088 Chairperson: John Vis The Secrets of Good Peak Shape in HPLC

More information

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS penta-hilic UHPLC COLUMNS Highly retentive, proprietary penta-hydroxy-ligand penta-hilic Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and

More information

(HILIC) Bill Champion Agilent Technologies, Inc opt 3/opt3/opt 2 HILIC - Agilent Restricted

(HILIC) Bill Champion Agilent Technologies, Inc opt 3/opt3/opt 2 HILIC - Agilent Restricted Hydrophilic Interaction Chromatography (HILIC) Bill Champion Agilent Technologies, Inc. 800-227-9770 opt 3/opt3/opt 2 william_champion@agilent.com Page 1 HILIC A method of recent attention Bill Champion

More information

InertSustain AQ-C18. HPLC, LC/MS Columns. Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases

InertSustain AQ-C18. HPLC, LC/MS Columns. Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases HPLC, LC/MS Columns InertSustain AQ-C8 Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases Physical Properties Silica : ES (Evolved Surface) Silica

More information

Comparison of different aqueous mobile phase HPLC techniques

Comparison of different aqueous mobile phase HPLC techniques June 009 ewsletter Pharmaceutical Analysis: What is Your Problem? SIELC Technologies, Inc., Prospect Heights, IL 0070 Pharmaceutical analysis involves liquid chromatography of various compounds, from active

More information

Kromasil. for your analytical HPLC. Kromasil. The way to peak performance in liquid chromatography

Kromasil. for your analytical HPLC. Kromasil. The way to peak performance in liquid chromatography Kromasil for your analytical HPLC Kromasil The way to peak performance in liquid chromatography Kromasil is known, worldwide, for its high performance and excellent total economy in preparative and industrial

More information

Separation of Large and Small Peptides by Supercritical Fluid Chromatography and Detection by Mass Spectrometry

Separation of Large and Small Peptides by Supercritical Fluid Chromatography and Detection by Mass Spectrometry Separation of Large and Small Peptides by Supercritical Fluid Chromatography and Detection by Mass Spectrometry Application Note Biologics and Biosimilars Author Edgar Naegele Agilent Technologies, Inc.

More information

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3 Cogent HPLC Columns Manufactured by Table of Contents QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3 C8 Bidentate C8 Extremely long

More information

Chemistry Instrumental Analysis Lecture 28. Chem 4631

Chemistry Instrumental Analysis Lecture 28. Chem 4631 Chemistry 4631 Instrumental Analysis Lecture 28 High Performance Liquid Chromatography () Instrumentation Normal Phase Chromatography Normal Phase - a polar stationary phase with a less polar mobile phase.

More information

APPLICATIONS TN Peptide Purification Method Development: Application for the Purification of Bivalirudin. Introduction

APPLICATIONS TN Peptide Purification Method Development: Application for the Purification of Bivalirudin. Introduction Peptide Purification Method Development: Application for the Purification of Bivalirudin Marc Jacob, Joshua Heng, and Tivadar Farkas Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 91 USA In this technical

More information

Method Development with ZirChrom's Ion Exchange Phases

Method Development with ZirChrom's Ion Exchange Phases For Peak Performance ZIRCHROM ION EXCHANGERS Phases for Sugars and Proteins Wide Range of Ion Exchange Selectivity No Shrinking or Swelling Use Any Organic Solvent Significantly Higher Efficiency than

More information

N α - 1 k. R s = Figure 1: The effect of N, α and k on resolution (Rs)

N α - 1 k. R s = Figure 1: The effect of N, α and k on resolution (Rs) A new high performance reversed phase column that leverages the advantages of a C phase with the extra selectivity of a pentafluorophenyl (PP) phase. columns separate mixtures not possible with ordinary

More information

Technical Guide Thermo Scientific Syncronis HPLC Columns

Technical Guide Thermo Scientific Syncronis HPLC Columns Technical Guide Thermo Scientific Syncronis HPLC Columns Consistent, predictable separations, Column after column, time after time Thermo Scientific Syncronis Columns When developing a new method, one

More information

Comparison Guide to C18 Reversed Phase HPLC Columns

Comparison Guide to C18 Reversed Phase HPLC Columns Comparison Guide to C18 Reversed Phase HPLC Columns Comparison Data on Commonly Used C18 Phases Stationary Phase Specifications Phases Compared According to Relative Hydrophobicity Phases Compared According

More information

Small Molecule Selectivity Sampler

Small Molecule Selectivity Sampler Small Molecule Selectivity Sampler HALO 90 Å C18, AQ-C18, BIPHENYL Fused-Core Particle Technology Why Choose Fused-Core Particle Technology? Fused-Core Out-Performs Totally Porous Particles. HALO particles

More information

LC Technical Information

LC Technical Information LC Technical Information Method Transfer to Accucore.6 μm Columns Containing solid core particles, which are engineered to a diameter of.6μm and a very narrow particle size distribution; Accucore HPLC

More information

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time Thermo Scientific Syncronis HPLC Columns Remarkable separations guaranteed time after time Syncronis HPLC and UHPLC Columns Remarkable separations guaranteed time after time When developing a new method,

More information

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph.

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph. Orosil OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph. Excellent organic base selectivity with very low asymmetry values Compatible

More information

UPLC for Synthetic Peptides: A User`s Perspective

UPLC for Synthetic Peptides: A User`s Perspective Tides 2007 Conference Las Vegas, May 23, 2007 UPLC for Synthetic Peptides: A User`s Perspective Holger Hermann, Jens Donath* Lonza AG, Switzerland Welcome to Lonza! One of the leading CMO Production facilities

More information

Overview Applications of NUCLEODUR HPLC Phases

Overview Applications of NUCLEODUR HPLC Phases verview Applications of HPLC Phases Phase Specification Characteristics* Stability Structure A B C octadecyl phase, high density coating multi-endcapping 8% C USP L ph stability -, suitable for LC/MS (Si-

More information

UPLC Method Development and Validation

UPLC Method Development and Validation UPLC Method Development and Validation Rev. 2 2008 Waters Corporation Challenges of Method Development Methods are developed throughout the drug development process Samples vary in complexity Redundancy

More information

Kromasil Eternity Designed for long life. For use in HPLC and UHPLC

Kromasil Eternity Designed for long life. For use in HPLC and UHPLC Kromasil Eternity Designed for long life For use in HPLC and UHPLC The long-lasting phase for demanding applications Imagine working under virtually no ph restrictions during method development. That s

More information

State - of - the -art C18 HPLC Columns

State - of - the -art C18 HPLC Columns An HPLC GL Sciences Newest and Most Advanced ODS Phase -New For State - of - the -art C HPLC s Improved Peak Shapes and Heights Enhancing Sensitivity High Resolution Fast Equilibration Compatible with

More information

Fast Separation of Vastly Different Compounds by Isocratic HPLC

Fast Separation of Vastly Different Compounds by Isocratic HPLC Fast Separation of Vastly Different Compounds by Isocratic HPLC Aimee N. Heyrman and Yury Zelechonok Resolution Systems, Inc. 590 E. 32nd St. Holland. MI, 49423 SIELC Technologies, 15 E. Palatine Rd, Suite

More information

[ OSTRO PASS-THROUGH SAMPLE PREPARATION PRODUCT ] The Simpler Way to Cleaner Samples

[ OSTRO PASS-THROUGH SAMPLE PREPARATION PRODUCT ] The Simpler Way to Cleaner Samples [ OSTRO PASS-THROUGH SAMPLE PREPARATION PRODUCT ] The Simpler Way to Cleaner Samples SIMPLE EASY EFFICIENT DEPENDABLE 2 waters.com/ostro 3 SIMPLE The Ostro Pass-Through Sample Preparation Product provides

More information

Kromasil Eternity Designed for long life

Kromasil Eternity Designed for long life Kromasil Eternity Designed for long life For use in HPLC and UHPLC Kromasil The long-lasting phase for demanding applications Imagine working under virtually no ph restrictions during method development.

More information

HPLC COLUMNS VaRian, inc. Pursuit XRs EXtRa REsolution. Ma XiMuM lifetime. ultimate PERfoRMancE.

HPLC COLUMNS VaRian, inc. Pursuit XRs EXtRa REsolution. Ma XiMuM lifetime. ultimate PERfoRMancE. HPLC COLUMNS VARIAN, INC. XRs Pursuit E X tr a Resolution. Ma ximum Life time. Ultimate Performance. The new standard in HPLC Designed to deliver ultimate performance in the most demanding laboratories,

More information

Inertsil Technical Library

Inertsil Technical Library HPLC COLUMN INERTSIL TECHNICAL LIBRARY H P L C C o l u m n Inertsil Technical Library Inertsil ODS-4, C8-4 Comparison of Performance List of Compared Columns Experimental Explanation, Analytical Conditions

More information

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity Monica Dolci, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20544 Key Words Hydrophilic, HILIC,

More information

Acclaim Mixed-Mode WCX-1

Acclaim Mixed-Mode WCX-1 Acclaim Mixed-Mode WCX-1 Product Manual for the Acclaim Mixed-Mode WCX-1 Column Page 1 of 28 PRODUCT MANUAL for the Acclaim Mixed-Mode WCX-1 Columns 4.6 x 150 mm, P/N (068353) 4.6 x 250 mm, P/N (068352)

More information

Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 10, 2000

Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 10, 2000 Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 0, 000 HPLC Column Troubleshooting What Every HPLC User Should Know :00 a.m. EST Telephone Number: 86-650-06 Chair Person: Tim Spaeder

More information

Inertsil ODS-EP Technical Information

Inertsil ODS-EP Technical Information Technical Information Advantages of The selectivity is completely different from those of conventional columns such as ODS column due to its specific polar group in the stationary phase. Durability can

More information

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma LC-MS/MS Method for the Determination of Diclofenac in Human Plasma J. Jones, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 20569 Key Words SPE, SOLA, Accucore RP-MS, diclofenac, Core

More information

Epic Aromatic Selectivity

Epic Aromatic Selectivity Epic Aromatic Selectivity HPLC Columns p h a r m a c e u t i c a l e n v i r o n m e n t a l c h e m i c a l b i o c h e m i c a l s e p a r a t i o n & p u r i f i c a t i o n ES Industries 701 S. Route