New Applications of Zirconia Based Stationary Phases
|
|
- Lorraine Skinner
- 5 years ago
- Views:
Transcription
1 ew Applications of Zirconia Based Stationary hases EAS 8 Bingwen Yan 1, Clayton V. Mceff 1, R.A. Henry, Dan owlan 1 1 ZirChrom Separations, Inc. 617 ierce St., Anoka, M 33 Independent Consultant, 983 Greenbriar Drive, State College, A 1681 Specialists in High Efficiency, Ultra-Stable hases for HLC
2 Surface Chemistry of Zirconia H H H H H H H HH Zr Zr Zr Zr Zr Zr Zr Zirconia chemistry is dominated by Lewis acid-base reactions Lewis Acid: Zr(IV): H + R 3 - Zr(IV): R H ther Lewis base examples: 3-, RC -, Catechol
3 Interaction Strength of Lewis Bases with Zirconia 3 Interaction Strength Lewis Base (L) Strongest Weakest Hydroxide hosphate Fluoride Citrate Sulfate Acetate Formate itrate Chloride Water Small Lewis bases with high electron density and low polarizability interact more strongly with Zr atoms. 3 J.A. Blackwell and.w. Carr, "Development of an Elutropic Series for the Chromatography of Lewis Bases on Zirconium xide," Anal. Chem. 6, (199). 3
4 Retention of Basic Analytes on ZirChrom -BD and ZirChrom -S Adsorbed Lewis base anion - - A + A + H A + A + olymer coating - H H H H H H Zr Zr Zr Zr Zr Zr Zr Zr BD, S Coating Reversed-hase (R) Moieties Lewis Base Anions Ion-Exchange (IEX) Sites Zr-L - :X + + A + = Zr-L - :A + + X + Zr- - :X + + A + = Zr- - :A + + X + A + : analyte cation, X + : counterion, L - : adsorbed Lewis base anion.
5 Effect of Ionic Strength on the Separation of Quaternary Amines Low Ionic Strength paraquat 3 nm diquat nm Column: Discovery Zr-S, 7.cm x.1mm ID, 3µ particles Mobile hase1: :, ( mm H 3, mm H HC, ph 7. w/ H H) : Acetonitrile Mobile hase: :, ( mm H 3, 1 mm H HC, ph 7. w/ H H) : Acetonitrile Flow:. ml/min Temp: as indicated Det: UV at nm & 3nm Inj: 1 µl Sample: diquat and paraquat in water; mg/l ea. 1 3 Time (min) High Ionic Strength k values for diquat are -3 at low ionic strength in % AC. paraquat 3 nm diquat nm k values for diquat decrease to about at high ionic strength without changing %AC. The classic method for reducing k in IE mode is to increase ionic strength, confirming IE mode Time (min) Data used by permission of Supelco
6 Effect of Reversed hase Character on the Separation of Quaternary Amines 3 % AC paraquat 3 nm diquat nm Column: Discovery Zr-S, 1cm x.1mm ID, 3µ particles Mobile hase 1:: : 3, ( mm H 3, 1 mm H HC 3, ph 7. w/ H H) : Water : Acetonitrile Mobile hase :: : 1, ( mm H 3, 1 mm H HC 3, ph 7. w/ H H) : Water : Acetonitrile Flow:.3 ml/min Temp: C Det: UV at nm & 3nm Inj: 1 µl Sample: diquat & paraquat in water; 1 mg/l ea Time (min) 1 % AC At 3% AC, the polymer coating adds very little to retention or selectivity for these ionic compounds. When nonionic compounds are present, changes in organic solvent strength will have a greater impact and can be used for optimizing resolution. 1 Time (min) Data used by permission of Supelco 6
7 Anticholinergics on Zr-BD H H 1, ipenzolate ( mg/l), Scopolamine (1 mg/l) Time (min) LC Conditions Discovery Zr-BD 1mm x.1mm i.d., 3 µm Mobile hase A: : [ mm H 3, ph 7. w/ H H]:water Mobile hase B: :3: [ mm H 3, ph 7. w/ H H]:water:AC Gradient 9:1 to :1 A:B over 18 minutes Temp = 8 o C, Flow =.3 ml/min, Inj vol = µl, UV nm, sample in ~6: Mobile phase A:MeH H H 3, Ipratropium (1 mg/l), Methscopolamine (1 mg/l) H, ropantheline ( mg/l) 6, xyphenonium (1 mg/l) Data used by permission of Supelco 7
8 MS Stationary hase Strategy 1. Chemisorb Ethylenediamine,,, - tetra(methylenephosphoni c)acid (EDTA) to the zirconia surface.. Quaternize amines on the zirconia surface with allyl iodide. zirconia - + H + - H BD BD n EDTA Chemisorptions BD/ dicumyl peroxide Crosslinking H H H H - + n Allyl iodide quaternization H + - H n 3. Coat polybutadiene (BD) on the chelator-modified zirconia surface and crosslink BD with allyl group and BD itself using dicumyl peroxide as initiator. 8
9 ZirChrom -MS Multi-Mode Character mau 17 1 /7 AC/mM H Ac ph=, T=3 o C, F=1mL/min, UV=1 H C C H C , Maleic acid, Benzonitrile H min 3, Benzyl amine mau /7 AC/mM H Ac, mm H F ph=, T=3 o C, F=1mL/min, UV=1 3 Multi-mode retention on ZirChrom -MS (MS1-6) Addition of fluoride blocks Lewis acid sites, decreasing the ligand exchange between zirconia and maleic acid mi n 9
10 Retention Comparison: Si-C18 vs Zr-BD K' yridine Lidocaine Basic harmaceutical retention in 8% AC yrilamine Tripeleneamine Methapyrilene Chlorpheniramine Thiothixene Doxepin Brompheniramine Solutes Atenolol Metoprolol xprenolol Amitryptyline Imipramine Alprenolol Desipramine ortryptyline Excess k due to IE mode Si-C18 Zr-BD LC Conditions: Machine-mixed 8/ AC/1 mm ammonium acetate ph=6.7 without ph adjustment; Flow rate, 1. ml/min.; Injection volume.1 ul; Temperature, 3 o C; Detection at nm; Columns, ZirChrom -BD, x.6 mm i.d. (3 um particles); Silica-C18 1 x.6 mm i.d., (3. um particles). 1
11 Beta Blockers on ZirChrom -MS mau 1 H min H H H H H H 1, Lidocaine, Atenolol 3, Metoprolol H H, xprenolol, Alprenolol LC Conditions: 6/3 AC/1 mm ammonium acetate ph=.; Flow rate, 1. ml/min.; Injection volume. µl; Temperature, 3 o C; Detection at nm; Columns, ZirChrom -MS, x.6 mm i.d. (3 um particles) H Multi-mode retention creates high k for bases even in high organic. Bases are charged at ph and can interact strongly with negative charges on phosphonate groups of EDTA. High organic mobile phase with ammonium acetate is ideal for LC- MS. 11
12 HLC Analysis of Cattle lasma Using ZirChrom -MS orm. 1 1 VWD1 A, Wavelength= nm (:\HCHEM\DATA\M31B\61116.D) VWD1 A, Wavelength= nm (:\HCHEM\DATA\M31B\61113.D) FMC-I Initial Separation Conditions A: AC B: mm H 3 ph=.8 /, 1 ml/min, T=3 o C. UV = nm C H Di-FMC- Lys H H H C H ipecolic acid Lysine orm VWD1 A, Wavelength= nm (:\HCHEM\DATA\M31B\6113.D) VWD1 A, Wavelength= nm (:\HCHEM\DATA\M31B\6113.D) FMC-I Di-FMC- Lys Initial Separation Conditions A: AC B: 3 g mm ammonium acetate ph 3 adjusted with formic acid +.3 g H 3 o C min 3/6 A/B 611 min / A/B 1 min Data used by permission of SarTec Corporation (Anoka, M) min min Analysis of pipecolic acid and lysine levels in cattle plasma ZirChrom -MS (MS1-16). IEX and R modes contribute to making a difficult separation. rganic solvent, ph and ionic strength are all important variables with ZirChrom-MS. 1
13 Surface Chemistry and Retention Mechanisms of QEI-Zirconia Anion-exchange Hydrophobic interactions Lewis acid-base interactions 13
14 Water-Soluble Vitamin Analysis on ZirChrom -SAX Thiamine (Vit. B 1 ) - yridoxine (Vit. B 6 ) 3 - icotinamide (form of Vit. B 3 ) - Riboflavin (Vit. B ) - icotinic acid (form of Vit. B 3 ) 6 - Ascorbic acid (Vit. C) 6 Vitamin C is strongly retained on ZirChrom -SAX min. LC Conditions: Column: ZirChrom -SAX, 1 x.6 mm i.d. (part number: ZR6-16), Mobile hase: mm Ammonium dihydrogenphosphate, ph., Flow rate: 1. ml/min. Temperature: 3 o C, Injection Vol.:. µl, Detection: UV at nm 1
15 Summary and Conclusions Mixed-mode applications have become popular for difficult applications where compounds vary widely in chemical nature. Several ZirChrom phases, including Zr-BD, Zr- S, Zr-MS and Zr-SAX, are ideal for mixed-mode applications and show unique selectivity. ZirChrom phases are stable and reproducible over a wider range of ph and temperature than silicabased phases. 1
16 Acknowledgements The authors wish to thank Supelco for permitting the use of data on quaternary amine compounds and SarTec for use of data on cattle plasma compounds. Trademarks used include: ZirChrom, Discovery For more information contact ZirChrom support at or stop by Booth. 16
Multi-mode Separations Using Zirconiabased Stationary Phases
Multi-mode Separations Using Zirconiabased Stationary Phases PITTC 2010 Dan owlan 1, Bingwen Yan 1, Clayton V. Mceff 1, R.A. Henry 2 1 ZirChrom Separations, Inc. 617 Pierce St., Anoka, M 55303 2 Independent
More informationZirconia-Based Phases as a Powerful Complement to Silica-Based Phases for LC and LC-MS under Non-extreme Mobile Phase Conditions
Zirconia-Based Phases as a Powerful Complement to Silica-Based Phases for LC and LC-MS under on-extreme Mobile Phase Conditions Richard A. Henry, Shawn R. Wyatt, Carmen T. Santasania and David S. Bell
More informationCharacteristics and Advantages of Zirconia-Based Stationary Phases for Use in Multi-Dimensional HPLC
Characteristics and Advantages of Zirconia-Based Stationary hases for Use in Multi-Dimensional LC Dwight Stoll and Clayton V. Mceff ZirChrom Separations, Inc. Multi-Dimensional Chromatography Workshop
More informationZirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS
Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS EAS 2005 Bingwen Yan 1, Clayton V. McNeff 1, Richard A. Henry 2, and David S. Bell 2 1 ZirChrom Separations, Inc., 617 Pierce Street, Anoka,
More informationFast Analysis of Small MW Analytes in a Beverage and Serum Samples on a Zirconiabased Strong Anion-Exchanger
Fast Analysis of Small MW Analytes in a Beverage and Serum Samples on a Zirconiabased Strong Anion-Exchanger Pittcon 2005 BINGWEN YAN 1, CLAYTON V. MCNEFF 1, 1 ZirChrom Separations, Inc., 617 Pierce Street,
More informationMethod Development with ZirChrom's Ion Exchange Phases
For Peak Performance ZIRCHROM ION EXCHANGERS Phases for Sugars and Proteins Wide Range of Ion Exchange Selectivity No Shrinking or Swelling Use Any Organic Solvent Significantly Higher Efficiency than
More informationNovel LC/MS-Compatible Stationary Phase with Polar Selectivity
Novel LC/MS-Compatible Stationary Phase with Polar Selectivity Carmen T. Santasania and David S. Bell Supelco 595 N. Harrison Rd., Bellefonte, PA 16823 T403168 GJU Introduction Stationary phases based
More informationOligonucleotide Separation on ZirChrom -SAX
Technical Bulletin #166 Oligonucleotide Separation on ZirChrom -SAX Absorbance () 5 45 4 35 3 25 2 15 1 5 Analytes Poly (A)- hydrolysate 2 4 6 8 1 12 Time (Minutes LC Conditions Column: ZirChrom -SAX,
More informationPolymer Coated Titania for Analytical and Preparative Reversed-Phase Chromatography
Polymer Coated tania for Analytical and Preparative Reversed-Phase Chromatography Pittcon 2005 CLAYT V. MCEFF 1, BIGWE YA 1, JCHE WIKLER 2 1 ZirChrom Separations, Inc., 617 Pierce Street, Anoka, M 55303
More informationPolymer Coated Titania for Analytical and Preparative Reversed-Phase Chromatography
Polymer Coated tania for Analytical and Preparative Reversed-Phase Chromatography EAS 200 BIGWE YA 1, CLAYT V. MCEFF 1, JCHE WIKLER 2 1 ZirChrom Separations, Inc., 617 Pierce Street, Anoka, M 303 2 Sachtleben,
More informationpenta-hilic UHPLC COLUMNS
penta-hilic UHPLC COLUMNS Highly retentive, proprietary penta-hydroxy-ligand penta-hilic Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and
More informationpenta-hilic UHPLC COLUMNS
penta-hilic UHPLC COLUMNS penta-hilic Highly retentive, proprietary penta-hydroxy-ligand Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and
More informationFast Separation of Vastly Different Compounds by Isocratic HPLC
Fast Separation of Vastly Different Compounds by Isocratic HPLC Aimee N. Heyrman and Yury Zelechonok Resolution Systems, Inc. 590 E. 32nd St. Holland. MI, 49423 SIELC Technologies, 15 E. Palatine Rd, Suite
More informationAnalysis - HPLC A.136. Primesep 5 µm columns B.136
Primesep 5 µm columns Primesep columns feature double functionality of the bonding i.e : alkyl chain with anionic or cationic group, chelating group. This feature creates unique selectivities when using
More informationImproving HPLC Column Selection and System Performance
Improving HPLC Column Selection and System Performance Richard A. Henry Penn State University T410170 sigma-aldrich.com LC Particle Innovation Leads the Way* Particle Size and Architecture (porosity) More
More informationIsomer Separation on ZirChrom -CARB
Bulletin #34 Isomer Separation on ZirChrom CARB Analytes 6 Ethylbenzene 5 3 mxylene 4 3 4 3 pxylene 4 Xylene 4 6 8 min LC Conditions Column: A: ZirChrom CARB, 5 4.6 mm; Mobile Phase: 5/5 A/B B: Water Flow
More informationRetention and Selectivity Variables
Applications of Ultra-Stable Phases for HPLC: High Temperature Ultra-Fast Liquid Chromatography and Thermally Tuned Tandem Column (T 3 C) Liquid Chromatography Yun Mao, Merck & Co. Jon Thompson, Peter
More informationXiqin Yang, Jun Dai, Peter W. Carr* Chemistry Department University of Minnesota
Comparison of the Reversed-Phase and Ion- Exchange Contributions to Retention on Polybutadiene Coated Zirconia and Octadecyl Silane Bonded Silica Phases Xiqin Yang, Jun Dai, Peter W. Carr* Chemistry Department
More informationToo Polar for Reversed Phase What Do You Do?
Too Polar for Reversed Phase What Do You Do? June 20, 2013 Mark Powell Columns and Consumables Technical Support Page 1 C8 or C18 Doesn t Always Do the Job Typical reversed phase conditions involve water/buffer
More informationHillel K. Brandes and David S. Bell Supelco, Liquid Separations, Bellefonte PA T GIH
Hillel K. Brandes and David S. Bell Supelco, Liquid Separations, Bellefonte PA 16823 T403163 GIH Abstract 2 ucleotides are ubiquitous in cells, with major functions including the control of cellular energetics,
More informationThe Analysis of Organic Acids in Foods and Beverages Using Reversed Phase HPLC
The Analysis of rganic Acids in Foods and Beverages Using Reversed Phase HPLC Rebecca E. Wittrig & Terrence S. Reid Restek Corporation Benner Circle, Bellefonte, PA 683 USA Restek Corporation www.restekcorp
More informationDionex IonPac AS28-Fast-4µm column
CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS-Fast-4µm Columns Product Specifications The Thermo Scientific Dionex IonPac AS-Fast-4µm column is a high-capacity, hydroxide-selective anionexchange column
More informationPut the. C18 aside. and take a look... Reasons. to try the. NEW Gemini C6-Phenyl
Put the C18 aside and take a look... 6 Reasons to try the EW Gemini Reason #6 ALTERATE SELECTIVITY to your C18 Column Adding to your method development options, Gemini offers additional polar and aromatic
More informationHICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited
HICHROM Chromatography Columns and Supplies LC COLUMNS SIELC Primesep Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)8 90 660 Fax: +44 (0)8 9 484 Email: sales@hichrom.co.uk
More informationFluoroPhenyl. Stationary Phase: Get the Power of HILIC and RP Modes in One LC Column. Pure Chromatography. Selectivity Accelerated
Get the Power of HILIC and RP Modes in One LC Column Selectivity Accelerated Stationary Phase: luorophenyl CH 3 Si CH 3 O Pure Chromatography www.restek.com/raptor The Raptor luorophenyl Column With Raptor
More informationYuhui Yang, An Trinh, Michael Ye, and Tom Henderson 595 North Harrison Road, Bellefonte, PA T HKB
Use of An Improved Version of C8+SCX Mixed-Mode Solid Phase Extraction Material for Clean Extraction and Recovery of Basic, Zwitterionic, Neutral and Acidic Compounds from Biological Fluids Yuhui Yang,
More informationSynthesis and Use of a New Covalently Bonded C18 Modified Carbon Clad Microporous Zirconia for Fast High Temperature Separations
Synthesis and Use of a New Covalently Bonded C18 Modified Carbon Clad Microporous Zirconia for Fast High Temperature Separations by Peter W. Carr, Clayton V. McNeff, Dwight R. Stoll, Danielle R. Hawker,
More informationReversed-Phase Method Development Guide
Zirconia-B Based Columns for HPLC Include s NEW QuickStart Guide! Reversed-Phase Method Development Guide Column Use Tips tel 1-8866-S STABLE-11 / fax 1-7763-4 421-22319 / www.zirchrom.com PART I / QUICK-START
More informationFluoroPhenyl. Stationary Phase: Get the Power of HILIC and RP Modes in One LC Column. Pure Chromatography. Selectivity Accelerated
Get the Power of HILIC and RP Modes in One LC Column Selectivity Accelerated Stationary Phase: luorophenyl CH 3 Si CH 3 O Pure Chromatography www.bgb-shop.com/raptor The Raptor luorophenyl Column With
More informationCation Exchange HPLC Columns
Cation Exchange PRP-X00 Polymeric cation exchange packing for separation of inorganic cations and organic cations. Easily separate mono or divalent cations. ph stable from to. Use with organic solvent
More informationSimultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS
Simultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS Richard Jack, Xiaodong Liu, Leo Wang, and Chris Pohl OT70806_E 08/13S 1 The world leader in serving science
More informationThermo Scientific Accucore XL HPLC Columns. Technical Manual
Thermo Scientific Accucore XL HPLC Columns Technical Manual Thermo Scientific Accucore XL HPLC Columns Based on Core Enhanced Technology using µm solid core particles, Accucore XL HPLC columns allow users
More informationZirChrom Newsletter Vol. #10 Sachtopore-NP and Sachtopore-RP, titania-based HPLC phases
ZirChrom Newsletter Vol. #10 Sachtopore-NP and Sachtopore-RP, titania-based HPLC phases Welcome to the tenth issue of ZirChrom's electronic newsletter. This newsletter introduces our titania-based HPLC
More informationAcclaim Mixed-Mode WCX-1
Acclaim Mixed-Mode WCX-1 Product Manual for the Acclaim Mixed-Mode WCX-1 Column Page 1 of 28 PRODUCT MANUAL for the Acclaim Mixed-Mode WCX-1 Columns 4.6 x 150 mm, P/N (068353) 4.6 x 250 mm, P/N (068352)
More informationColumnsAcclaim PolarAdvantage II (PA2) HPLC Columns
ColumnsAcclaim PolarAdvantage II (PA) HPLC Columns A Unique and Complementary Alternative to Conventional C8.8 Column: Acclaim PA, µm Peaks: ( ppm each) Dimensions:. mm. Maleate Mobile Phase: MeOH/.% NH
More informationAnalysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography
Application Note Inorganic Ions, Water Testing, Minerals, Metals, Basic Chemicals Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography Authors Anne Mack, Adam Bivens
More informationLeave Your Footprint!
Leave Your Footprint! Luna HILIC Luna HILIC columns retain a water-enriched layer on the surface of the silica. This water layer facilitates the transfer of polar compounds into the stationary phase for
More informationfor Acclaim Mixed-Mode WCX-1
for Acclaim Mixed-Mode WCX- Product Manual for the Acclaim Mixed-Mode WCX- Column Page of 8 Product Manual for Acclaim Mixed-Mode WCX- Columns Acclaim Mixed-Mode WCX-, 3µm, Analytical column, 3.0 x 50mm
More informationTCI Dual ~Mixed-Mode Mode column~
TCI Dual ~Mixed-Mode Mode column~ TCI Chromatography Department Mixed-Mode Column Target compound is basic Choose DS + Cation-Exchange Type Target compound is acidic Choose DS + Anion-Exchange Type o ion-pair
More informationPackings for HPLC. Packings for HPLC
Summary of packings for HPLC In analytical HPLC, packings with particle sizes of 3 to 10 µm are preferred. For preparative separation tasks, also particles with diameters larger than 10 µm are applied.
More informationThermo Scientific. Anion-Exchange Column
CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS9-µm Anion-Exchange Column Product Specifications The Themo Scientific Dionex IonPac AS9-µm high-capacity, hydroxide-selective, anion-exchange column is
More informationgroups I and II cations, amines, divalent transition metals
IC Columns Introduction Alltech IC Column Specifications Column Composition ph Range Applications Anion Exchange Columns Allsep polymer-based anion ph 0 inorganic anions, weak and strong acid ions, exchanger,
More informationKromasil Eternity Designed for long life
Kromasil Eternity Designed for long life For use in HPLC and UHPLC Kromasil The long-lasting phase for demanding applications Imagine working under virtually no ph restrictions during method development.
More informationPharmaceutical Analysis of API and Counter Ions in Complex Formulations in a Single Injection
Pharmaceutical Analysis of API and Counter Ions in Complex Formulations in a Single Injection Matthew Neely Pittcon Conference & Expo 2014 March 2-6, 2014 1 The world leader in serving science Outline
More informationHPLC & LC-MS. Techniques to Improve Speed, Resolution and Sensitivity without Investing in Capital Equipment
HPLC & LC-MS Techniques to Improve Speed, Resolution and Sensitivity without Investing in Capital Equipment 2010 Innovation Seminar Series Supelco, Div. of Sigma-Aldrich Overview of Presentation Chromatographer
More informationThe Development of ZrO 2 Based HPLC: From Colloid to Column
The Development of 2 Based PLC: From Colloid to Column Department of Chemistry University of Minnesota utline Colloid to particle. Stationary phase synthesis. Polybutadiene- 2 Polystyrene - 2 P-EDTA/PBD
More informationReversed Phase Solvents
Part 1. General Chromatographic Theory Part 2. verview of HPLC Media Part 3. The Role of the Mobile Phase in Selectivity Part 4. Column Care and Use Reversed Phase Solvents 2 Solvents for RP Chromatography
More informationHow proteins separate on reverse-phase HPLC
1 Reverse Phase How proteins separate on reverse-phase HPLC RP chromatography separates proteins through the interaction of the hydrophobic foot of the protein with a nonpolar surface of the particle RP
More informationAcclaim Mixed-Mode WAX-1 Columns
User Manual Acclaim Mixed-Mode WAX- Columns 06565 Revision 03 October 05 Product Manual for the Acclaim Mixed-Mode WAX- Column Page of 3 Product Manual for Acclaim Mixed-Mode WAX- Columns 5µm, 0 x 50 mm,
More informationHydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity
Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity Monica Dolci, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20544 Key Words Hydrophilic, HILIC,
More informationSetting the Standard for ph Method Development
U.S. Patent o. 7, 56, 67 Setting the Standard for ph Method Development ugged reversed phase HPLC columns that offer extended lifetime at extreme ph conditions and excellent stability for reproducible,
More informationLC Columns with Liquid Separation Cell Technology
Obelisc LC Columns with Liquid Separation Cell Technology Obelisc HPLC Columns - Liquid Separation Cell Technology Introduction Obelisc HPLC columns are the latest, innovative columns from SIELC Technologies,
More informationThermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance
CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS Anion-Exchange Column Product Specifications The Thermo Scientific Dionex IonPac AS anion-exchange column is designed for the fast analysis of inorganic
More informationYour Reversed Phase Method
PLC Columns for Your Reversed Phase Method Balanced Non-Polar & Polar Selectivity Strong Non-Polar & Polar Selectivity Strong Polar & Aromatic Selectivity Unique Isomeric & alogenated Selectivity Robust
More information3µm Fortis C18. Fortis 2.1µm. Increased Efficiency. Scalability and Sensitivity
Fortis 2.1µm 2.1µm Fortis C18 (2) High Efficiency Robust Particles Operate to 15,000psi Fully Scalable to analytical and prep size Fortis 2.1µm particles are designed to provide characteristics, which
More informationLC Technical Information
LC Technical Information Method Transfer to Accucore.6 μm Columns Containing solid core particles, which are engineered to a diameter of.6μm and a very narrow particle size distribution; Accucore HPLC
More informationcolumns IonPac AS22 Anion-Exchange Column
columns IonPac AS Anion-Exchange Column The IonPac AS is a carbonate based anion-exchange column designed for the determination of inorganic anions and low-molecular-weight organic acids including fluoride,
More informationThe Theory of HPLC. Ion Pair Chromatography
The Theory of HPLC Ion Pair Chromatography i Wherever you see this symbol, it is important to access the on-line course as there is interactive material that cannot be fully shown in this reference manual.
More informationanion-exchange column
columnsionpac ASA Anion-Exchange Column The IonPac ASA is a carbonateselective anion-exchange column designed for the fast separation of inorganic anions, including fluoride, chlorite, bromate, chloride,
More informationSunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending
Patent pending Website : www.chromtech.net.au E-mail : info@chromtech.net.au telno : 0 97 0... in AUSTRALIA A Novel Bonding Technique (patent pending) An unique trifunctional silyl-reagent was developed
More informationcolumns IonPac AS17-C Anion Exchange Column
columns IonPac AS-C Anion Exchange Column The IonPac AS-C is a hydroxide-selective anion exchange column designed for fast gradient separation of inorganic anions. The key application for the AS-C column
More informationThermo Scientific Dionex IonPac AS23 Anion-Exchange Column
Chromatography Thermo Scientific Dionex IonPac AS Anion-Exchange Column Product Specifications The Thermo Scientific Dionex IonPac AS high-capacity, carbonate based anion-exchange column is designed for
More informationHPLC Column Product Guide
HPLC Column Product Guide 00-00 A new generation of HPLC columns for more powerful method development and peak performance Microbore Analytical Semi-P Preparative Preparative tel -866-STABLE- / fax -76--9
More information1. Ion exchange chromatography
1. Ion exchange chromatography Ion Exchange Chromatography Most popular method for the separation or purification of charged molecules. In cation exchange chromatography, positively charged molecules are
More informationIt s hot! ZIC -chilic
It s hot! ZIC -chilic Complementary selectivity for HPLC and LC-MS separation of polar hydrophilic compounds EMD Millipore Corp. is a subsidiary of Merck KGaA, Darmstadt, Germany ZIC -chilic Your benefits
More informationSeparation of Structurally Similar Steroids on HALO C18 and PFP
Application Note: 047-STR Separation of Structurally Similar Steroids on HALO C8 and PFP, 4 G009 HALO C8 HALO PFP 4. Prednisone. Cortisone. Prednisolone 4. Hydrocortisone 0 4 5 6 7 Columns: 4.6 x 00 mm,
More information4. Ion chromatography (IC) 4.1. Educational aims and objectives
4. Ion chromatography (IC) 4.1. Educational aims and objectives Principles of ion chromatography method and instrumentation. Methods for ionic compounds analysis including ion chromatography and its subtypes.
More informationHints for Strong Ion Exchange Resins
Hints for Strong Ion Exchange Resins Chromatography Application Note AN98 Abstract Ion exchange columns are a powerful means of isolating and purifying compounds, but their use is limited due to lack of
More information(HILIC) Bill Champion Agilent Technologies, Inc opt 3/opt3/opt 2 HILIC - Agilent Restricted
Hydrophilic Interaction Chromatography (HILIC) Bill Champion Agilent Technologies, Inc. 800-227-9770 opt 3/opt3/opt 2 william_champion@agilent.com Page 1 HILIC A method of recent attention Bill Champion
More informationIon Chromatography. Anion Exchange. Chromatography Ion Exchange Theory. Dr. Shulamit Levin
Ion Exchange Chromatography Chromatographic Process BA Mobile phase Stationary Phase A Shula Levin Bioforum B Distribution: K = C s/c m B shulal@zahav.net.il http://shulalc.co.il/ A Elution through the
More informationNew On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography
New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography Yan Liu, Zhongqing Lu, and Chris Pohl, Thermo Fisher Scientific, Sunnyvale, CA USA Overview Purpose: In this work, new high-pressure
More informationAn Overview of the the Development of Stationary Phases for Reversed-Phase Liquid Chromatography
An Overview of the the Development of Stationary Phases for Reversed-Phase Liquid Chromatography Analytical Potential of Stable Phases for Reversed-Phase Liquid Chromatography by Jacek Nawrocki, Jon Thompson,
More informationInertSustain AQ-C18. HPLC, LC/MS Columns. Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases
HPLC, LC/MS Columns InertSustain AQ-C8 Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases Physical Properties Silica : ES (Evolved Surface) Silica
More informationACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development
ACE C8-Amide For increased polar retention and alternative selectivity Alternative selectivity for method development Improved separations with polar, acidic, basic and phenolic compounds High efficiency
More informationThermo Scientific. Acclaim Trinity P2. Column Product Manual. P/N: October Part of Thermo Fisher Scientific
Thermo Scientific Acclaim Trinity P2 Column Product Manual P/N: October 2013 Part of Thermo Fisher Scientific Product Manual for Acclaim Trinity P2 Columns Acclaim Trinity P2, 3µm, Analytical Column, 3.0
More informationHigh Temperature Ultra Fast Liquid Chromatography. Peter W. Carr, Jon Thompson, Dwight Stoll, and Adam Schallinger
High Temperature Ultra Fast Liquid Chromatography Peter W. Carr, Jon Thompson, Dwight Stoll, and Adam Schallinger Conclusions 1. To do fast LC, use a WEAK eluent and a HOT column.. Use a highly retentive
More informationfor Acclaim Trinity TM P1
for Acclaim Trinity TM P Product Manual for Acclaim TRINITY P Columns Page of 4 Product Manual for Acclaim Trinity TM P Columns 07556 Acclaim Trinity P, 3µm, 4.6 x 00mm 07556 Acclaim Trinity P, 3µm, 4.6
More informationHigh Performance Liquid Chromatography
Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN
More informationHigh Performance Liquid Chromatography
Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 1 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN
More informationOptimizing GPC Separations
Optimizing GPC Separations Criteria for Solvent Selection True sample solubility (Polarity and Time dependant) Compatibility with columns Avoid non-size exclusion effects (eg adsorption by reverse phase
More informationCation Exchange HPLC Columns
Cation Exchange HPLC Columns Hamilton offers seven polymeric packing materials for cation exchange separations. Type Recommended Application(s) PRP-X00 PRP-X00 PRP-X800 HC-0 HC-7 Ca + HC-7 H + HC-7 Pb
More informationKromasil Eternity Designed for long life. For use in HPLC and UHPLC
Kromasil Eternity Designed for long life For use in HPLC and UHPLC The long-lasting phase for demanding applications Imagine working under virtually no ph restrictions during method development. That s
More informationHigh Performance Liquid Chromatography. Table 1: Allowed HPLC Adjustment of USP <621> and EP <2.2.46>
High Performance Liquid Chromatography HPLC-9 Ultra-high Speed Analysis of Ibuprofen within USP Allowed Limits by Nexera Method Scouting In recent years, high-throughput analytical techniques have
More informationSuperior Chromatographic Performance Recommended anion-exchange column for separation of haloacetic acids prior to MS or MS/MS detection
columns IonPac AS Anion-Exchange Column The IonPac AS is a highcapacity, hydroxide-selective anion exchange column designed for separation of haloacetic acids (HAAs) and bromate in drinking water prior
More informationIC Columns Introduction
IC Columns Introduction Alltech IC Column Specifications Column Composition ph Range Applications Anion Exchange Columns Allsep polymer-based anion ph 0 inorganic anions, weak and strong acid ions, exchanger,
More informationMechanisms of retention in HPLC
Mechanisms of retention in HPLC María Celia García-Álvarez-Coque Department of Analytical Chemistry University of Valencia Valencia, Spain https://sites.google.com/site/fuschrom/ 1 Part 3 Mechanisms of
More informationBasic Principles for Purification Using Supercritical Fluid Chromatography
Basic Principles for Purification Using Supercritical Fluid Chromatography Jo-Ann M. Jablonski, Christopher J. Hudalla, Kenneth J. Fountain, Steven M. Collier, and Damian Morrison Waters Corporation, Milford,
More informationLC and LC/MS Column Selection Flow Chart
LC and LC/MS Column Selection Flow Chart To use the column selection diagram below, simply follow the path for your analyte and mobile phase. At the far right, follow your final column selection to the
More informationLiquid Chromatography Mass Spectrometry. Shimadzu Corporation, UK; 2 Phytocontrol, France; 3 Shimadzu France, France. Trimesium S + CH 3 ETU
LAA-A-LM-E89 Liquid Chromatography Mass Spectrometry LCMS C8 Highly Polar Pesticide Multi-Residue Analysis in Food Safety by LC-MS/MS David R. Baker, Eric Capodanno, Mikaël Levi Shimadzu Corporation, UK;
More informationA Platform Method for Pharmaceutical Counterion Analysis by HPLC
A Platform Method for Pharmaceutical Counterion Analysis by HPLC Xiaodong Liu, Mark Tracy, and Christopher Pohl; Thermo Fisher Scientific, Sunnyvale, CA, USA Overview Results and Simple, fast, economical
More informationcolumns IonPac AS18 Anion-Exchange Columns
columns IonPac AS Anion-Exchange Columns The IonPac AS is a hydroxideselective anion-exchange column designed for the determination of inorganic anions and low-molecularweight organic acids including fluoride,
More informationRapid Post-Blast Inorganic Explosive Analysis by Suppressed Ion Chromatography
Rapid Post-Blast Inorganic Explosive Analysis by Suppressed Ion Chromatography L. Canella, C. Austin, A. Beavis, P. Maynard, M. Dawson, C Roux, and P. Doble Centre for Forensic Science, University of Technology,
More informationcolumns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules
columns Acclaim Mixed-Mode WCX- for Separating Basic Molecules The Acclaim Mixed-Mode WCX- is a novel, high-efficiency, silica-based column specially designed for separating various basic analytes. This
More informationHPLC Preparative Scaleup of Calcium Channel Blocker Pharmaceuticals Application
HPLC Preparative Scaleup of Calcium Channel Blocker Pharmaceuticals Application Pharmaceuticals Author Cliff Woodward and Ronald Majors Agilent Technologies, Inc. 2850 Centerville Road Wilmington, DE 19808
More informationcolumns IonPac SCS 1 Silica Cation Separator
columns IonPac SCS Silica Cation Separator The SCS Silica Cation Separator is designed for use with nonsuppressed conductivity detection, or single-column ion chromatography (SCIC). This column is particularly
More informationHPLC method development using alternative selectivities
HPLC method development using alternative selectivities Frank Michel, Sigma-Aldrich Germany R. A. Henry, W. K. Way, C. T. Santasania, D. S. Bell Supelco/Sigma-Aldrich, USA Three Factors Control HPLC and
More informationMixed-Mode, Weak Anion-Exchange, Solid-Phase Extraction Method for the Extraction of Niflumic Acid from Human Plasma
Mixed-Mode, Weak Anion-Exchange, Solid-Phase Extraction Method for the Extraction of Niflumic Acid from Human Plasma Ken Meadows, Thermo Fisher Scientific, Runcorn, UK Application Note 20789 Key Words
More informationHICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited
HICHROM Chromatography Columns and Supplies LC COLUMNS SeQuant ZIC-HILIC Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk
More informationThermo Scientific Dionex IonPac AS25 Anion-Exchange Column. Minutes
columns Thermo Scientific Dionex IonPac AS Anion-Exchange Column Isocratic Separation of Sulfur Species and Inorganic Anions Using the Dionex IonPac AS Column. Fluoride. Bromate. Chloride. Nitrite. Bromide.
More informationSeparation of Barbiturates
Bulletin # Separation of Barbiturates - Barbital - Metharbital - Butethal - exobarbital - Mephobarbital - Pentobarbital 8 7 -C8,. mm Mobile Phase: //7 A/B/C A: ACN B: TF C: mm Ammonium phosphate, p 7.
More information