Analog - Digital multimeters

Size: px
Start display at page:

Download "Analog - Digital multimeters"

Transcription

1 CAT-IV -3, MI, Satpur, Nashik-4 7,India. Tel.: , ax : Page of / 5 / I I / 7 / B

2 Automatic Terminal Blocking System (ABS) The automatic Terminal blocking system prevents incorrect connection of the test leads and incorrect selection of the measured. This reduces danger to the user, the meter and the system to a remarkable extent. Interface And Software RISH com The multimeters are fitted with a serial RS-3 C interface via which the measured values can be transmitted to a PC. These values, electrically isolated, are transmitted to the attachable interface adaptor with infrared light through the case* MIN/MAX Value Storage In addition to the display of the actual measured value, the minimum or maximum value can constantly be updated and stored. Indication Of Negative Values On The Analog Scale When measuring quantities, also negative values are shown on the analog scale so that variations of the measured value can be observed at the zero point. Indication Of Negative Values On The Analog Scale The measuring principle employed permits the measurement of the root-mean-square value (TRMS) of quantities and mixed quantities ( and ) regardless of the waveform. Automatic Data Hold* The DATA HOLD function makes it possible to hold the digitally displayed measured value. According to a patented method, it is ensured that no freak value but the actual measured value is held in the case of rapid changes in measured quantities. The held measured value appears on the digital display. The actual measured value continues to be shown on the analog scale. Autoranging / Manual Range Selection The measured values are selected with rotary switch. The is automatically matched to the measured value. The can also be selected manually via the AUTO/MAN push button. Continuity Test This permits testing for short circuit and open circuit. In addition to the display, a facility of sound signal is available. Overload Warning A sound signal indication violation of the overload limits. Protective holster for rough duty A holster of soft rubber with tilt stand protects the meter against damage in the case of shock and drop. The rubber material makes for the meter to stand firmly even on vibrating surface. Top model RISH multi 8S The top model Rish multi 8S features a 4 3/4 digit display (3 digits)as well as the following additional functions : Event counter, measurement of the duration of the event, time counter (stop watch), data compare,db measurment, wide-range capacitance measurement. Calibration RISH multi is automatically calibrated with respect to luke 55 / Wavetek 9. Automatic calibration is done through a developed calibration software with RS3 connection to the multimeter. Every multimeter is provided with the Test Certificate which is traceable to National / International standards. All the meters can be recalibrated at the Rishabh Instruments. Applied rules and standards : Temperature Measurement It is possible to use all models of RISH multi series, in direct connection of temperature sensor Pt / Pt. The meters automatically detects the type of sensors connected to it & displays directly measured temperature. Signalling in the case of a blown fuse The display USE points to a blown fuse. Power economizing circuit The meter disconnects automatically when the measured value remains unchanged for about minutes and no operating control was operated during this time. The disconnection facility can be disabled. * Protected by patent rights IEC 6-: DIN EN 6 part VDE 4 - DIN 4375 IS 3875 EN 636: EN 636: VDI/VDE 354 DIN EN 659 DIN VDE 47 part Safety requirements for electrical equipment for measurement, control and laboratory use. Digital measuring instruments Generic emission standard; Residential, commercial and light industry. Generic immunity standard; residential, commercial and light industry. Reliability of measuring and control equipment. Test equipment and test procedures -Degrees of protection provided by enclosures (IP Code). -3, MI, Satpur, Nashik-4 7,India. Tel.: , ax : Page of / 5 / I I / 7 / B

3 Specifications RISH multi S... 6S Meas. function V V ~ A A ~ RISHMulti 3. mv 3.mV 3. V 3. V 3. V V 3. V 3. V 3. V V 3. V 3. V 3. V V 3. A 3. ma 3. ma 3. ma 3. A. A 3. ma 3. ma 3. ma. A ) 3. A ) 3. A 3. ma 3. ma. A Measuring range S 3S 4S 5S 6S 6A 6A Resolution V V mv mv mv V mv mv mv V mv mv mv V na A A A ma ma A A A ma ma ma A A ma Input impedance M // < 4 p Voltage drop. approx. S 3S 4S / 5S/6S 5 mv 5 mv 5 mv 5 mv. + 5 (> D) 5 mv 5 mv 65 mv.5 + V V V mv mv 3/7mV 7 mv 5 mv V 5 mv V > G // < 4 p > G // < 4 p M // < 4 p M // < 4 p M // < 4 p M // < 4 p M // < 4 p M // < 4 p M // < 4 p M // < 4 p M // < 4 p M // < 4 p M // < 4 p 5 mv V 3/7mV No-load voltage 5 mv 5 mv V 7 mv S 3S 4S 5S 6S 5) 5) (> D) V 7 mv.5 + (> D) Inherent deviation of the digital display + (...% of meas. val. +...digits) for reference condition.75 + (... 3 D).75 + (> 3 D) (> D). + 5 (> D) (> D) A. + 5 (< D) (> D) (> D) (> D).5 + (> D).5 + (> D) (> D) (> D) (> D) (> D) (> D) 4) Overload capacity Overload Overload value duration V effective.36 A.36 A 7) 7) 7) A 7) min Measuring function V V ~ A A ~ k 3. k 3. k 3. M 3. M. V m m k k mv max. 3. V max. 3. V max. 3. V Discharge resistance U max 5) ) V effective min 3. n 3. n p p n n 5 k 5 k 5 k 5 k.5 V.5 V.5 V.5 V 6) V / effective min Sensor min V min % k 3. k. k %.. % ).5 + 9)...k: + 5 D 9)...k:+5 D/k < 3 k: V < 3 k: 3V < k: 3 V % C C C C C. C. C. C. C Pt Pt Kelvin + 5 D. + 5 Kelvin + D. + V effective min C TRMS measurement ) Direct display with clip-on transformer : 4) At C C 5) With zero setting; w/o zero setting + 35 digits 6) With zero setting; w/o zero setting + 5 digits 7) RISH multi 3S (w/o 6 A fuse!) : 6A, A for 5 min; RISH multi 4S... 6S: A for 5 min, 6A for 3s ~ ~~ 8) Range 3 V : U E =.5 V... Vrms rms 3 V : U E = 5 V rms... 3Vrms 3 V : U E = 5 V rms... Vrms 9) On the range 3V rectangular signal positive at one end V, f = const., not or integer multiple. Without sensor -3, MI, Satpur, Nashik-4 7,India. Tel.: , ax : Page 3 of / 5 / I I / 7 / B

4 Analog - Digital multimeters Specifications RISH multi 8S Meas. function V db Measuring range Resolution 3. mv 3. V 3. V 3. V. V µv µv mv mv mv Inherent error of the digital display Input impedence + (...% of rdg.+... digits) at reference conditions ~ ~ ~ ~ > G M M M M 5 M // < 4 p 5 M // < 4 p 5 M // < 4 p 5 M // < 4 p 5 M // < 4 p.5 + 3; ). + 3 (> 6 Digit) (> 3 Digit) (> 3 Digit) (> 3 Digit) (> 3 Digit) See table below as at V~ 4) +.5 db Voltage drop. approx. ) Overload capacity Meas. Overload value V RMS Overload function duration V db ~ ~ ma A 3. µa 3. ma 3. ma 3. ma 3. A. A na 5 mv na 5 mv µa 3 mv µa 3 mv µa ma 5 mv 4 mv 5 mv 5 mv 3 mv 3 mv 5 mv 4 mv (> 3 Digit). + 3 (> 3 Digit). + 5 (> 3 Digit). + 3 (> 3 Digit). + 5 (> 3 Digit). + 3 (> 3 Digit).36 A 5) A 5 min ma A No-load voltage Short circuit current k 3. k 3. k 3. M 3. M 3. V- m m k mv max. 4. V max. 4. V max. ma max. µa max. µa max. µa max.. µa max.. µa 3). + 6; V RMS min Discharge resist. U max 3. n 3. n 3. n 3. µ 3. µ 3. µ 3 µ µ p p p n n n µ µ.5 M.5 M 5 k 5 k 5 k.5 k.5 k.5 k 6) f min 4 V 4 V 4 V 4 V V V V V. + 8; ). + 8; ) V RMS min Pt Pt k 3. k. k ). + 3 < 3 k; 3 V 8).5 Kelvin ) 8).5 Kelvin + 3 8) < 3 k; V < k 3 V V rms sine min. db ranges Measuring ranges 3 m 3 V~ 3 V~ 3 V~ V~ Display span at reference voltage U =.775 V - 48 db db - 38 db... + db - 8 db db + db db + db db Display (db) = lg U x(v) /.775 V Display span at reference voltage U ref (V) - 4 db... + db -6 db... + db - 8 db db - db db - db db Display (db) = lg U x(v) / U ref (V) TRMS measurement values < digit (<5 digit for 3mV) will be supressed ) At ) With zero adjuster; without zero adjuster 4) At a resolution of. db 5) 6 A for 3s 6) Lowest measurable frequency with a measuring signal which is symmetrical to zero 7) Range 3 V ~ : U e = V eff/rms... V eff/rms 3 V ~ : U e = V eff/rms... V eff/rms 3 V ~ : U e = V eff/rms... V eff/rms 8) Without sensor -3, MI, Satpur, Nashik-4 7,India. Tel.: , ax : Page 4 of / 5 / I I / 7 / B

5 o Analog - Digital multimeters Measuring voltage with resistance measurement S... 6S Measuring current with diode test and / or continuity test S... 6S. U X V 3 M. ma l x M 3 3 k 3 3 k 3 3 D Voltage U across x the resistance R x to be measured as a function of measuring range and display..5..5,5,5 Ux V Measuring current I x as a function of the displayed voltage U x on the device under test. Measuring voltage with resistance measurement 8S Measuring current with diode test and / or continuity test 8S U X V 3 M 3 M 3 3 k 3 3 k Voltage U xacross the resistance R x to be measured as a function of measuring range and display l ma x Measuring current I x as a function of the displayed voltage U x on the device under test. 3 D.5 3 UV x Reference conditions Ambient temperature +3C + K Relative humidity 45%... 55% requency of the measured Waveform of the measured Battery voltage Sinusoidal 8V +. V -3, MI, Satpur, Nashik-4 7,India. Tel.: , ax : Page 5 of / 5 / I I / 7 / B

6 Display Display RISH multi S... 6S LCD field (65 mm x 3 mm) with analog indication and digital display and with annunciators for unit of measurement, function and various special functions MAN DATA MIN MAX ON k% mva k M n µ + 7 Analog Indication Scale length Scaling Polarity indication Overrange indication Sampling rate LCD scale with pointer 55 mm on V and A ; 47 mm on all other ranges with 35 scale divisions on, 3 with 3 scale divisions on all other ranges With automatic reversal By triangle readings/s, On readings/s 9 8 Display RISH multi 8S Digital Display/ height of numerals Rish multi S 6S, 7 segment numerals / 5mm Rish multi 8S: 7-segment numerals/ mm 3 MAN DATA MIN MAX ON EVENTS k% µmva k M ZERO. ºC n ON Number of counts Overange display Polarity display Sampling rate Rish multi S 6S, 3 ¾ digit 3 counts Rish multi 8S: 4 ¾ digit 3 counts "OL" is shown "-" sign is shown, When positive pole to " " readings/s, On and C: reading/s. Display with low battery voltage. Display with sound signal on 3. Symbol for CONTINUOUSLY ON 4. Digital display with indication of decimal point and polarity 5. Display with manual range selection as well as with data and MIN/MAX hold 6. Display of the selected function 7. Display of the unit of measurement 8. Display with overrange 9. Pointer for analog indication. Scale for analog indication. Indication that negative analog range is exceeded. Display of the unit C when measuring temperature 3. Display with time counter switched on -3, MI, Satpur, Nashik-4 7,India. Tel.: , ax : Page 6 of / 5 / I I / 7 / B

7 quantities and variations for S... 6S quantities and variations for 8S Temperature requency of the measured Waveform of the measured 3) C range Measured /... + and < < 45 > > 4... k > k... k 5... < < 45 > k 5... < <45 > k Crest factor C...3 > /3 mv V.5 + V ) 3 µ A... 3 ma 3A / (6) A A ~ ) k... 3 M 3 M ) 3 n... 3 µ 3 µ % ), 4) Variation + (...% of meas. val digits) S... 4S 5S 6S K D % of rdg. + 3 % of rdg. The permissible crest factor C of the to be measured is a function of the displayed value : Voltage measurement 5 V V C Current measurement 3 D Temperature requency of the measured Waveform of the measured 3) C 5 ) Measured / Variation range + (...% of meas. val digits) and < < > 5...< 3 > 3... < 45 > > 4... k > k... k 5... < < 45 > k 5... < 45 > k Crest factor C...3 > V,V ~ 3 µa / 3 ma 3 ma 3 ma... A 3 µa... 3 ma ~ 3A / A 3 3 k... 3 M 3 M 3 n... 3 µ 3 µ m V~ 4), 4) Kelvin + D % of rdg. + 3 % of rdg. The permissible crest factor C of the to be measured is a function of the displayed value : Voltage measurement 5 V V C ~ Current measurement D 3 range Measured / Variation S... 6S range Measured / Variation Battery voltage 5)... < 7.9 V > 8. V.... V V A 3 / 3 / ºC 3 k... 3 M n, µ % + D + 4 D + 4 D + 6 D + 4 D + 3 D + D + D + D Battery voltage 5)... < 7.9 V > 8. V.... V V A 3 n... 3 µ + 6 D + 3 D + 3 D + (% of rdg.+ D) + D + D + 6 D + 5 D Relative humidity DATA MIN / MAX 75 % 3 days Meter off A ~ %, A ~ x Intrinsic error + D + D Relative humidity DATA MIN / MAX 75 % 3 days Meter off V, db, A,,, V, db, A,, V, db, A,,, x inherent deviation + D + D + D + D With temperature; Error data is per K change in temperature. With frequency; Error data is valid from a display of 3 digits. ) With zero setting 3) With unknown waveform (crest factor C > ), the measurement must be made with manual range selection. 4) Except for waveform 5) rom the time the symbol " appears. With zero setting ) With temperature; Error data is per K change in temperature. With frequency; Error data is valid from a display of % of the. 3) With unknown waveform (crest factor C > ), the measurement must be made with manual range selection. 4) Except for waveform 5) rom the time the symbol " appears. -3, MI, Satpur, Nashik-4 7,India. Tel.: , ax : Page 7 of / 5 / I I / 7 / B

8 Common mode voltage range Disturbance variable max. Disturbance variable max. 5, 6 Disturbance variable, Normal nom. value of meas, range at a time, mode voltage max., 5, 6 Disturbance variable max. V -- Meas. range S... 6S V V Damping > db > 7 db > 7 db > 6 db > 5 db > db Common mode voltage range Disturbance variable max. Disturbance variable max. 5, 6 Disturbance variable, Normal nom. value of meas, range at a time, mode voltage max., 5, 6 Disturbance variable max. V -- Meas. range 8S V 3 mv 3 3 V Damping > db > 8 db > 7 db > 6 db > 48 db > db Response time Response time for S... 6S (after manual range selection) Response time for 8S (after manual range selection) Measured V A A ~ M 3M n, µ, 3, 3k 3, k % ( ) % (> ) of analog indication.7 s.5 S 4 S.7 S Response time of digital display.5 S S 5 S.5 S max.... 3S max. S max..7 S max. 9 S max..5 S Leap function of the measured from to 8% from to 5% from to 5% Measured V A A ~ M 3M.5 S 4 S S 3 n... 3 µ 3 µ µ > Response time of digital display.5 S.7 S 3 mv : 8S of analog indication.7 S max. S max. 7 S max. 4 S max..5 S 5 S.5 S max. S max. 7 S max. 4 S max..5 S max. 3 S Leap function of the measured from to 8% from to 5% from to 5% Power supply Electrical Safety (Except 3S) Battery Operating time Battery test 9-V flat cell battery: manganese-dioxide cell according to IEC 6. alkaline Manganese cell according to IEC 6 LR 6 or corresponding NiCd storage battery With alkaline-manganese cell: RISH multi 6S Approx. hours on V, A Approx. 8 hours on, (S 5S) approx. 6 hours on V~, (6S) with interface operation times x.7 RISH multi 8S: approx. hours on V approx. 9 hours on V~, A Automatic display of the " " symbol, when the battery voltage drops below approximately 7 V. Protection class Overvoltage category Nominal voltage Degree of pollution Nominal Test Voltage Emission Immunity As per IEC 6-: III IV V 6V Electromagnetic compatibility EMC 6.7KV~ acc. To IEC 348/DIN VDE 4 EN 636: class B EN 58-: 99 EN 636: IEC KV atmospheric discharge 4 KV contact discharge IEC V/m uses use link for the ranges up to 3 ma.6a/v 6.3 mm x 3 mm; Switching capacity ka on V/ and ohmic load; in connection with power diodes protects all current s up to 3 ma Date interface Type Data transmission Baud rate RS-3C, serial, according to DIN 94 Optical, with infrared light through the case 89 bit/s use link for ranges up to A 6 A / V or 5 A / V mm X 38 mm, Switching capacity 3 ka on 6 and ohmic load; protects the 3 A and A ranges up to V -3, MI, Satpur, Nashik-4 7,India. Tel.: , ax : Page 8 of / 5 / I I / 7 / B

9 O RISHABH RISHABH Analog - Digital multimeters Environmental conditions Operating controls S... 8S Working temperature range Storage temperature range Climatic class Altitude above sea level Mechanical configuration Protection type Dimensions Weight Scope of delivery RISH multi S... 6S: - C C RISH multi 8S, - C C -5 C C (excl. batteries) RISH multi S... 6S: z/-/5/7/75% with reference to VDI/VDE 354 RISH multi 8S: z/-/5/7/75% with reference to VDI/VDE 354 up to m or meters; IP 5, for connection sockets: IP 84 mm x 95 mm x 35 mm.35 kg, approx., incl. battery multimeter Probe Set copy of operating instructions test certificate rubber holster with tilt stand and carrying strap warranty card set of extra fuses. RISH multi SI 3 on- Esc ON/O RISH multi 6S ON MAN DATA MIN MAX.6 T V 3mA A fused V CAT II/6V CAT III k% µmva k M n µ V V ~ ma V~ ~ A! TRMS V C ma A Option storage adapter RISHmulti SI3 Analog-to-digital multimeter RISHmulti S LC display ON/O push-button 3 Push-button for data hold and MIN/MAX storage 4 Push-button for manual range selection 5 Multi-function push-button 6 Switch for measurement functions 7 Connection sockets with automatic blocking system Warranty 3 year against defects in materials and workmanship & calibration from the date of purchase. -3, MI, Satpur, Nashik-4 7,India. Tel.: , ax : Page 9 of / 5 / I I / 7 / B

10 Ordering Information Order Code Designation Type Order Order code Code Multimeter Cable set Carrying Bag Voltage probe upto 3 KV Voltage probe upto 3 KV Clip on current transformer A, ma/a Shunt A / mv Temperature sensor pt Temperature sensor pt RISH multi s RISH multi 3s RISH multi 4s RISH multi 5s RISH multi 6s RISH multi 8s KS HV 3 HV 3 Z35 GE 477 Z 349 Z Single channel storage pack including memory adapter SI 3, Cable & Software RISHcom our channel storage pack including 4 nos memory adapter SI 3, Cable & Software RISHcom CH pack 4 CH pack , MI, Satpur, Nashik-4 7,India. Tel.: , ax : Page of / 5 / I I / 7 / B

VIBRATION METER. Instruction Manual.

VIBRATION METER. Instruction Manual. VIBRATION METER 840063 Instruction Manual CONTENTS Title Page I. Introduction... 2 II. Panel Description... 3 III. Operating Instructions A. General Measurement Procedures... 3~4 B. Peak... 5 C. Data Hold...

More information

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows: The basic PC software is supplied free with the recorder. There is an additional charge for the extensive Data Acquisition Software supplied with communication of RS-232/422/485 or Ethernet. The Ordering

More information

Operating Instructions for Digital Manometer. Model: MAN-SD

Operating Instructions for Digital Manometer. Model: MAN-SD Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5

More information

Acceleration/Velocity/Displacement VIBRATION METER

Acceleration/Velocity/Displacement VIBRATION METER Acceleration/Velocity/Displacement VIBRATION METER Model : VB-8220 Your purchase of this VIBRATION METER marks a step forward for you into the field of precision measurement. Although this METER is a complex

More information

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER Model : TM-2000 Your purchase of this THERMOMETER marks a step forward for you into the field of precision measurement. Although this THERMOMETER is a

More information

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER ISOCON-6 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting

More information

User Manual VX4750 Function Generator Module

User Manual VX4750 Function Generator Module User Manual VX4750 Function Generator Module 070-9151-05 This document applies for firmware version 2.60 and above. Copyright Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S.

More information

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -A - Introduction - Thank for your purchasing MITSUBISHI ELECTRIC MELPRO TM D Series Digital Protection

More information

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

CALYS 80P. Field pressure calibrator with high accuracy 0.01% Field pressure calibrator with high accuracy 0.01% CALYS 80P is a field pressure calibrator within CALYS range with high accuracy of 0.01%. Description CALYS 80P is a field pressure calibrator within CALYS

More information

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202 Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202 Your purchase of this VIBRATION METER marks a step forward for you into the field of precision measurement. Although this METER is

More information

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER CAUTION: This equipment is designed for connection to mains voltages and must be used in accordance with this guide. If it is not, the safety protection

More information

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en T20WN Torque transducers Data Sheet Special features - Nominal (rated) torques 0.1 N m, 0.2 N m, 0. N m, 1 N m, 2 N m, N m, 10 N m, 20 N m, 0 N m, 100 N m, 200 N m - Accuracy class: 0.2 - Contactless transmission

More information

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure DATASHEET Pascal ET Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure - electrical signals (ma, mv, V, ) - temperature (TC and

More information

DIGITAL THERMOMETER OPERATOR S MANUAL

DIGITAL THERMOMETER OPERATOR S MANUAL DIGITAL THERMOMETER OPERATOR S MANUAL 51 206-3722 52 206-3738 DIGITAL THERMOMETER OPERATOR'S MANUAL RS 51 206-3722 RS 52 206-3738 1 2 INTRODUCTION 1-1 Unpacking and Inspection Upon removing your new Digital

More information

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation S95.U0 / S95.U Head mounted temperature transmitters, programmable, Pt 00 (RTD), thermocouples, electrical isolation Resistance thermometer (,, wire circuit) Thermocouples Resistance remote signalling

More information

VIBRATION TACHOMETER OPERATION MANUAL. 3 in 1. Model : VT Your purchase of this

VIBRATION TACHOMETER OPERATION MANUAL. 3 in 1. Model : VT Your purchase of this 3 in 1 VIBRATION TACHOMETER Model : VT-8204 Your purchase of this VIBRATION TACHOMETER marks a step forward for you into the field of precision measurement. Although this VIBRATION TACHOMETER is a complex

More information

ph/redox Measurement CPM 280

ph/redox Measurement CPM 280 Technical Information TI 346C/07/en/07.03 51511752 ph/redox Measurement CPM 280 Battery-driven pocket meter for ph and redox measurement Application CPM 280 is a compact pocket meter for measuring ph value

More information

792A AC/DC Transfer Standard

792A AC/DC Transfer Standard 92A AC/DC Transfer Standard Technical Data Support for your most demanding ac measurement requirements ppm total uncertainty Traceable to national standards range: 2 mv to 00 V Frequency range: Hz to 1

More information

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities instruments 5 YEARS G U A R A N T E E Quality at a reasonable price The optimum combination

More information

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS FEATURES AND BENEFITS* Up to 1,000,000 duty cycles or 10 year DC life 48V DC working voltage Active cell balancing Temperature output Overvoltage outputs available High power density TYPICAL APPLICATIONS

More information

792A AC/DC Transfer Standard

792A AC/DC Transfer Standard 92A AC/DC Transfer Standard Technical Data Support for your most demanding ac measurement requirements ppm total uncertainty Traceable to national standards range: 2 mv to 00 V Frequency range: Hz to 1

More information

VIBRATION METER Acceleration & Velocity Model : VB-8201HA

VIBRATION METER Acceleration & Velocity Model : VB-8201HA VIBRATION METER Acceleration & Velocity Model : VB-8201HA TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS...2 3. FRONT PANEL DESCRIPTION...4 3-1 Display...4 3-2 BNC socket of meter...4 3-3 RMS/PEAK

More information

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006% ATEX documenting multifunction calibrator with high accuracy 0.006% is the top instrument of our range of ATEX documenting multifunction calibrators. Description is the top instrument of our range of ATEX

More information

PHOENIX CONTACT - 04/2016. Features

PHOENIX CONTACT - 04/2016. Features Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.

More information

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8. TF / TF -Ex Field mounted temperature transmitters, PROFIBUS PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN P R O F I PROCESS FIELD BUS B U S Input Resistance thermometer (,, -wire

More information

BMXART0814 analog input module M340-8 inputs - temperature

BMXART0814 analog input module M340-8 inputs - temperature Product data sheet Characteristics BMXART0814 analog input module M340-8 inputs - temperature Product availability : Stock - Normally stocked in distribution facility Price* : 1485.00 USD Main Range of

More information

S95.3U02 / S95.3U12. Head mounted temperature transmitters, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation

S95.3U02 / S95.3U12. Head mounted temperature transmitters, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation S95.U0 / S95.U Head mounted temperature transmitters, HART programmable, Pt 00 (RTD), thermocouples, electrical isolation Resistance thermometer (,, wire circuit) Thermocouples Resistance remote signalling

More information

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS FEATURES AND BENEFITS* Up to 14 year DC life 56V DC working voltage Resistive cell balancing Overvoltage outputs High power density 4U, half-rack package UL registered TYPICAL APPLICATIONS UPS systems

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer LDSR 0.3-TP/SP1 I P R N = 300 ma For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Closed

More information

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels TF 0 / TF 0-Ex Field mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.69 EN USA Input Resistance thermometer (,, wire circuit) Thermocouples

More information

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820 Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820 Your purchase of this PEN VIBRATION METER marks a step forward for you into the field of precision measurement.

More information

473-SHX Dew Point Mirror

473-SHX Dew Point Mirror Humidity and Temperature Reference Hygrometer For Temperature up to 125 C Precise and stable chilled mirror dew point mirror technology High temperature optical components High temperature sample fan Cable

More information

566/568. Infrared Thermometers. Getting Started

566/568. Infrared Thermometers. Getting Started 566/568 Infrared Thermometers Getting Started PN 2812159 August 2007 Rev. 2, 4/08 2007-2008 Fluke Corporation. All rights reserved. Printed in China. Product specifications are subject to change without

More information

5SJ4...-.HG Circuit Breakers to IEC and UL 489

5SJ4...-.HG Circuit Breakers to IEC and UL 489 Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is

More information

Pressure transmitters for industrial applications MBS 32 and MBS 33

Pressure transmitters for industrial applications MBS 32 and MBS 33 Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer

More information

Operating instructions Pressure sensor PN / / 2007

Operating instructions Pressure sensor PN / / 2007 Operating instructions Pressure sensor PN42 704298 / 00 0 / 2007 Contents afety instructions... 3 2 Function and features... 4 3 Function... 5 3. witching function... 5 4 Installation... 5 5 Electrical

More information

InfraRed Thermometer with Laser Pointer

InfraRed Thermometer with Laser Pointer User Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com InfraRed Thermometer with Laser Pointer MODEL IR400 Introduction Congratulations

More information

Instruction Manual SEFRAM Thermal Camera

Instruction Manual SEFRAM Thermal Camera Instruction Manual SEFRAM 9830 Thermal Camera EN Introduction The SEFRAM 9830 Thermal Camera (the Product) can display thermal gradient, temperature readings, map and measure the infrared energy radiated

More information

INSTRUCTION MANUAL RS 51 & RS 52 DIGITAL THERMOMETER

INSTRUCTION MANUAL RS 51 & RS 52 DIGITAL THERMOMETER INSTRUCTION MANUAL RS 51 & RS 52 DIGITAL THERMOMETER EN FR IT DE RS 51 & RS 52 DIGITAL THERMOMETER INSTRUCTION MANUAL 2 INTRODUCTION 1-1 Unpacking and Inspection Upon removing your new Digital Thermometer

More information

Non-Contact Safety Systems CMS

Non-Contact Safety Systems CMS Selection table for non-contact safety system // Evaluation units Connection Desi Read head contact assembly Assured switch-on distance S ao [mm] Assured switch-on distance S ar [mm] Number of outputs

More information

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS SUMMARY OF MODELS OF HRC FUSE-LINKS Type PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size

More information

BMXART0814 analog input module M340-8 inputs - temperature

BMXART0814 analog input module M340-8 inputs - temperature Product data sheet Characteristics BMXART0814 analog input module M340-8 inputs - temperature Main Range of product Product or component type Electrical connection Input output isolation Input level Analogue

More information

5730A High Performance Multifunction Calibrator. Extended specifications

5730A High Performance Multifunction Calibrator. Extended specifications 730A High Performance Multifunction Calibrator Extended specifications General Specifications Warm-Up Time... Twice the time since last warmed up, to a maximum of 30 minutes. System Installation... Rack

More information

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol with PROFIBUS-PA procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application 00 II () G FISCO The SINEAX VK 66 is a temperature transducer for use in aumation systems

More information

Infrared Hand-Held Thermometers

Infrared Hand-Held Thermometers Infrared Hand-Held Thermometers measuring monitoring analysing Model: TIR-H... Measuring range from -2 to 5 C to -32 to 9 C Measuring accuracy: ±1% to ± 2% of measured value Option: analogue output, RS

More information

MODEL: MO Digital DC Milliohm Meter OPERATING INSTRUCTION

MODEL: MO Digital DC Milliohm Meter OPERATING INSTRUCTION MODEL: MO-1210 Digital DC Milliohm Meter OPERATING INSTRUCTION Index 1. Introduction...1 1-1.Brief...1 1-2.Features...1 1-3.Specification...1 2.Machine...4 2-1.Panel......4 2-2.LCD............4 3.Operation...5

More information

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -C - Safety section - This Safety section should be read before starting any work on the relay.

More information

One-hand ph/temperature measuring instrument

One-hand ph/temperature measuring instrument One-hand ph/temperature measuring instrument testo 205 ph tip embedded in breakage-proof plastic ph Combined penetration tip with temperature probe Maintenance-free gel electrolyte C Measurement tip exchangeable

More information

FAZ tripping characteristics at 30 C: B, C, D to IEC/EN FAZ tripping characteristics at 30 C: R to IEC/EN

FAZ tripping characteristics at 30 C: B, C, D to IEC/EN FAZ tripping characteristics at 30 C: R to IEC/EN FAZ, AZ High-Capacity Tripping Characteristics Moeller HPL011-001/00 1/07 FAZ tripping characteristics at 0 C: B, C, D to IEC/EN 0 9 FAZ tripping characteristics at 0 C: R to IEC/EN 0 97 t [s] 700 00 100

More information

TeSys circuit-breakers

TeSys circuit-breakers Presentation Thermal-magnetic motor circuit-breakers types GV2, GV and GV7 GV2-ME, GV2-P, GV-ME and GV7-R motor circuit-breakers are -pole thermal-magnetic circuit-breakers specifically designed for the

More information

für for T5-Lampen fluorescent in Multi-Lamp-Technologie

für for T5-Lampen fluorescent in Multi-Lamp-Technologie Dimmbare Dimmable electronic elektronische control Vorschaltgeräte gear für for T-ampen fluorescent in Multi-amp-Technologie lamps in technology M-tec Performance characteristics Dimmable ECG in Multi-amp

More information

Product Data. Brüel & Kjær B. Sound Power Source Type Introduction

Product Data. Brüel & Kjær B. Sound Power Source Type Introduction Product Data Sound Power Source Type 425 USES: Determination of sound power output of equipment by the Substitution Method Determination, by the Juxtaposition Method, of sound power output of equipment

More information

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR 19 TECHNOLOGY. NET Protector Surge Arrester. Protects switches, HUBs and telecommunication

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR 19 TECHNOLOGY. NET Protector Surge Arrester. Protects switches, HUBs and telecommunication Surge Arrester Protects switches, HUBs and telecommunication systems Class D according to EN 0 possible (Gigabit Ethernet) Variably equippable patch panels Units available with plug-in inputs and outputs

More information

Sealing possibility Electrical endurance (ops) Mechanical endurance (ops) Overvoltage category Standards

Sealing possibility Electrical endurance (ops) Mechanical endurance (ops) Overvoltage category Standards Miniature circuit breaker ETIMAT 7,7 0.5 Rated voltage Rated current Rated frequency Rated short-circuit capacity Energy limiting class characteristic Build-in width Mounting on the rail 0/00 V AC, max.

More information

Automatic titrators, TitroMatic

Automatic titrators, TitroMatic 112 TitroMatic These are the fourth generation of CRISON titrators. CRISON has over 25 years experience in this field and knows that, for certain applications, the performance and cost of large titrator

More information

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet: abc instruments international FLT5A Thermometer Land Instruments International Dronfield, S18 1DJ England Telephone: (1246) 417691 Facsimile: (1246) 41585 Email: infrared.sales@landinst.com Internet: www.landinst.com

More information

CNY17 Series. Optocoupler with Phototransistor Output. Vishay Telefunken. Description. Applications. VDE Standards.

CNY17 Series. Optocoupler with Phototransistor Output. Vishay Telefunken. Description. Applications. VDE Standards. Optocoupler with Phototransistor Output Description The CNY7 series consists of a phototransistor optically coupled to a gallium arsenide infrared-emitting diode in a 6-lead plastic dual inline package.

More information

Model HHG 21 GAUSS / TESLA METER

Model HHG 21 GAUSS / TESLA METER Model HHG 21 GAUSS / TESLA METER Instruction Manual Manual UN-01-244 April, 2001 Rev. A OMEGA All rights reserved. This symbol appears on the instrument and probe. It refers the operator to additional

More information

Multi-function, economical instrument with 4 functions in the same casing. Accessibility and safety: large-dimension terminals Insulated circuits

Multi-function, economical instrument with 4 functions in the same casing. Accessibility and safety: large-dimension terminals Insulated circuits 200 > Measurement and instrumentation Programmable digital transducers TRIAD 2 range Programmable digital transducers with to 4 analogue outputs Programmable accuracy class PRODUCT ADVANTAGES Up to 4 PROGRAMMABLE

More information

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO. DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link

More information

Mini Environmental Quality Meter

Mini Environmental Quality Meter Mini Environmental Quality Meter 850027 Mini Environmental Quality Meter 850027 Copyright 2012 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced

More information

Bright Advance Corporation

Bright Advance Corporation USER INSTRUCTIONS TABLE OF CONTENTS INSTRUCTIONS FOR USE2 PREPARING TO USE THE SCALE2 DISPLAYS3 KEYBOARD FUNCTION4 OPERATION7 COUNTING14 DIFFERENT KEYBOARD TYPES21 INTERFACE31 POWER SOURCES40 1 INSTRUCTIONS

More information

Product Data. Brüel & Kjær B. Sound Intensity Calibrator Type 3541

Product Data. Brüel & Kjær B. Sound Intensity Calibrator Type 3541 Product Data Sound Intensity Calibrator Type 3541 USES: Sound intensity and particle velocity calibrations Sound pressure calibration Measurement of pressure-residual intensity index FEATURES: Intensity

More information

Heat stress index. Dewpoint. pressure. altitude

Heat stress index. Dewpoint. pressure. altitude Kestrel 4200 Measures Volume air flow in cfm, L/s, m³/s, m³/m, m³/h Air velocity (current, average, and maximum) Heat stress index Windchill Relative humidity Dewpoint in F or C Humidity ratio Barometric

More information

Model 5060 GAUSS / TESLA METER

Model 5060 GAUSS / TESLA METER Model 5060 GAUSS / TESLA METER Instruction Manual Manual UN-01-229 Rev. E, ECO 13097 Item No. 359924 Sypris Test & Measurement All rights reserved. This symbol appears on the instrument and probe. It refers

More information

OP-02 / OP-03 / OP-04

OP-02 / OP-03 / OP-04 FS-i Series Check Weighing Scales Option OP-02 / OP-03 / OP-04 WM+PD4001368 Contents 1. OP-02 BATTERY... 2 1-1. Using the OP-02 SLA Battery... 2 2. OP-03 RS-232C / RELAY OUTPUT... 4 2-1. Installation...

More information

Siemens AG Miniature Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.

Siemens AG Miniature Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens. Siemens AG 05 Totally Integrated Power SENTRON Configuration Manual Edition 0/0 siemens.com/lowvoltage Siemens AG 05 Siemens AG 05 Introduction 5SL miniature circuit breakers 5SY and 5SP miniature circuit

More information

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer INSTRUCTION MANUAL Thermometer DUAL-LASER TARGETING 12:1 DISTANCE- TO-SPOT RATIO AUTO-SCAN MAX/MIN/AVG/DIFF HIGH/LOW ALARM BACKLIT DISPLAY AUTO POWER-OFF ADJUSTABLE EMISSIVITY IR5 2m -22 752 F (-30 400

More information

ebro has expanded its range of measuring instruments in the food area even further: ebro Data Logger Family EBI 20

ebro has expanded its range of measuring instruments in the food area even further: ebro Data Logger Family EBI 20 ebro has expanded its range of measuring instruments in the food area even further: ebro Data Logger Family EBI 20 For comprehensive documentation and monitoring of temperature, pressure and humidity in

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer HO-NP series I P N = 4, 6, 12, 15 A Ref: HO 4-NP, HO 6-NP, HO 12-NP, HO 15-NP For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary

More information

E2T0 DVP

E2T0 DVP 29-5-26 5116868-E2T DVP-11363-1 ENGLISH Thank you for choosing Delta s DVP series PLC. DVP4TC-E2 temperature measurement module receives 4 points of external thermocouple temperature sensors (J-type, K-type,

More information

Impedance relay and protection assemblies

Impedance relay and protection assemblies RXZK 21H, 22H, 23H 509 006-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE970175) (SE970184) Features Micro-processor based impedance relay with R and X settings

More information

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability DM70 Hand-held Dewpoint Meter Truly Fast Response - Superior Long-term Stability DM70 - When Dry Air Is Important The Vaisala DM70 Hand-held Dewpoint Meter offers stable and fast measurement for industrial

More information

CNY64/ CNY65/ CNY66. Optocoupler with Phototransistor Output. Vishay Telefunken. Description. Applications. VDE Standards

CNY64/ CNY65/ CNY66. Optocoupler with Phototransistor Output. Vishay Telefunken. Description. Applications. VDE Standards Optocoupler with Phototransistor Output Description The CNY64/ CNY65/ CNY66 consist of a phototransistor optically coupled to a gallium arsenide infrared-emitting diode in a 4-lead plastic package. The

More information

PHASED OUT. FL ballasts Electronic dimming. PCA TC BASIC Y II, W BASIC compact

PHASED OUT. FL ballasts Electronic dimming. PCA TC BASIC Y II, W BASIC compact EL Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A BAT Noise-free precise control via DSI signal, switchdim or corridorfunction Nominal life

More information

SCTP20 Programmable 2-Wire Temperature Transmitter, Head Mount

SCTP20 Programmable 2-Wire Temperature Transmitter, Head Mount 20 Programmable 2-Wire Temperature Transmitter, Head Mount Configurable Transmitters Description Each 20 2-wire transmitter is designed for measuring temperature using thermocouples or RTDs. The input

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer HO-NSM series I PN = 8, 15, 25 A Ref: HO 8-NSM, HO 15-NSM, HO 25-NSM For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the

More information

Kestrel 4500 Pocket Weather Tracker

Kestrel 4500 Pocket Weather Tracker Kestrel 4500 Pocket Weather Tracker For years our customers have been asking for wind direction along with wind speed. New for 2007, the Kestrel 4500 does just that with its built in digital compass. But

More information

HD32.2 WBGT Index HD32.3 WBGT-PMV. [ GB ] - WBGT index. - PMV index and PPD

HD32.2 WBGT Index HD32.3 WBGT-PMV. [ GB ] - WBGT index. - PMV index and PPD HD32.2 WBGT Index HD32.3 WBGT-PMV [ GB ] - WBGT index. - PMV index and PPD [ GB ] [ GB ] Description HD32.2 WBGT Index is an instrument made by Delta Ohm srl for the analysis of WBGT index (Wet Bulb Glob

More information

PRODUCT DATA. Sound Intensity Calibrator Type 3541-A. Uses and Features

PRODUCT DATA. Sound Intensity Calibrator Type 3541-A. Uses and Features PRODUCT DATA Sound Intensity Calibrator Type 3541-A Type 3541-A enables calibration of sound intensity measuring instruments by using a coupler designed especially for sound intensity calibrations. Intensity-probe

More information

General characteristics, Products

General characteristics, Products The Feature Packed line of Manual Motor Protectors Eaton s new XT family of Manual Motor Protectors (MMPs) features a pushbutton or rotary ON/OFF manual disconnect, Class adjustable bimetallic overload

More information

THERMYS 150. Advanced field reference thermometer / temperature calibrator

THERMYS 150. Advanced field reference thermometer / temperature calibrator Advanced field reference thermometer / temperature calibrator THERMYS 150 is an all-in-one high accurate documenting field reference thermometer for thermocouples (14 types), resistive probes (12 types)

More information

HAL501...HAL506, HAL508 Hall Effect Sensor ICs MICRONAS INTERMETALL MICRONAS. Edition May 5, DS

HAL501...HAL506, HAL508 Hall Effect Sensor ICs MICRONAS INTERMETALL MICRONAS. Edition May 5, DS MICRONAS INTERMETALL HAL1...HAL, HAL Hall Effect Sensor ICs Edition May, 1997 1--1DS MICRONAS HAL1...HAL HAL Hall Effect Sensor IC in CMOS technology Common Features: switching offset compensation at khz

More information

MKV AC Capacitors Damping B High dielectric strength High peak-current capability Especially suitable for snubber circuits

MKV AC Capacitors Damping B High dielectric strength High peak-current capability Especially suitable for snubber circuits MKV AC Capacitors B 25 835 High dielectric strength High peak-current capability Especially suitable for snubber circuits Construction Self-healing Plastic dielectric Oil-impregnated tubular windings (no

More information

Time - timing relays 1 Industrial relays, solid state output, width 22.5 mm

Time - timing relays 1 Industrial relays, solid state output, width 22.5 mm haracteristics Zelio ime - timing relays Industrial relays, solid state output, width. mm Presentation 08 he E9 range of relays is designed for simple, repetitive applications with short and intensive

More information

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed

More information

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820 Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820 Your purchase of this PEN VIBRATION METER marks a step forward for you into the field of precision measurement.

More information

MM74C150 MM82C19 16-Line to 1-Line Multiplexer 3-STATE 16-Line to 1-Line Multiplexer

MM74C150 MM82C19 16-Line to 1-Line Multiplexer 3-STATE 16-Line to 1-Line Multiplexer MM74C150 MM82C19 16-Line to 1-Line Multiplexer 3-STATE 16-Line to 1-Line Multiplexer General Description The MM74C150 and MM82C19 multiplex 16 digital lines to 1 output. A 4-bit address code determines

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

Coating Thickness Gauge TW-8. art. nr Thoma Tel./Fax: Operation Manual

Coating Thickness Gauge TW-8. art. nr Thoma Tel./Fax: Operation Manual Coating Thickness Gauge art. nr. 59252 Table of contents 1. Technical specifications...3 2. Getting started...3 3. Gauge manual...6 The price of this product includes the recycling fee of 0,10 PLN Guarantee...11

More information

O P E R A T I N G M A N U A L

O P E R A T I N G M A N U A L OPERATING MANUAL WeatherJack OPERATING MANUAL 1-800-645-1061 The baud rate is 2400 ( 8 bits, 1 stop bit, no parity. Flow control = none) To make sure the unit is on line, send an X. the machine will respond

More information

CONTINUOUS FINE DUST MEASURING SYSTEM

CONTINUOUS FINE DUST MEASURING SYSTEM CONTINUOUS FINE DUST MEASURING SYSTEM PM 10 - PM 2,5 - PM 1 Particle count distribution DustMonit ENGINEERING SRL Via Paolo Diacono, 1-20133 Milano (MI) - ITALIA Tel ++39.02.26684830 - E-mail : info@conteng.it

More information

1 pc Charge Injection, 100 pa Leakage CMOS 5 V/5 V/3 V 4-Channel Multiplexer ADG604

1 pc Charge Injection, 100 pa Leakage CMOS 5 V/5 V/3 V 4-Channel Multiplexer ADG604 a FEATURES 1 pc Charge Injection (Over the Full Signal Range) 2.7 V to 5.5 V ual Supply 2.7 V to 5.5 ingle Supply Automotive Temperature Range: 4 C to +125 C 1 pa Max @ 25 C Leakage Currents 85 Typ On

More information

ABB i-bus KNX Analogue Input AE/A 2.1

ABB i-bus KNX Analogue Input AE/A 2.1 Product Manual ABB i-bus KNX Analogue Input AE/A 2.1 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/A 2.1. Subject to changes and errors excepted. Exclusion

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer HO-NP/SP33 series I PN = 8, 15, 25 A Ref: HO 8-NP/SP33, HO 15-NP/SP33, HO 25-NP/SP33 For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the

More information

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS. Type PVA10 / PV10 PV14 PV22 Rated current I n up to 32 A up to 63 A up to 125 A Rated voltage U n

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS. Type PVA10 / PV10 PV14 PV22 Rated current I n up to 32 A up to 63 A up to 125 A Rated voltage U n Varius SUMMARY OF MODELS OF HRC FUSE-LINKS Type A / Rated current I n up to A up to up to A Rated voltage U n AC V, V V, V, 9 V V, V, 9 V DC V V V Fuse-link size x8 x x8 Utilization category of the fuse-link

More information

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual Latest generation testo air velocity & IAQ probes with cable handle Instruction manual Contents Contents 1 About this document... 5 2 Safety and disposal... 5 3 System description... 6 4 Description of

More information

/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2

/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2 / way valves (solenoid actuated diaphragm with forced lifting) /4... Damped operation Operation without differential Suitable for vacuum igh flow rate For systems with low or fluctuating Brass body Wide

More information

Tantalum chip capacitors

Tantalum chip capacitors Ordering code: Date: July 2006 EPCOS AG 2006. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent

More information

3VT4 Molded Case Circuit Breakers up to 1000 A

3VT4 Molded Case Circuit Breakers up to 1000 A VT4 Molded Case Circuit Breakers up to 00 A Catalog Technical nformation VT4 Molded Case Circuit Breakers up to 00 A General data / - Overview Circuit breakers Switch disconnectors / - Selection and ordering

More information