Experience the Zebron Difference

Size: px
Start display at page:

Download "Experience the Zebron Difference"

Transcription

1 Experience the Zebron Difference Premier GC Column Selection Guide

2 Introducing the Zebron Experience Proven Performance Zebron GC columns are engineered by expert Phenomenex GC scientists that created key J&W technologies. Our inventive philosophy and expertise in GC column manufacturing allow us to continuously develop award-winning column chemistries. We provide best-in-class technologies and support to make your analysis easier let the Zebron experience put you first. Our Customers Come First Complimentary Services: Column and accessory selection support Method optimization assistance Thousands of resources and applications online If Zebron columns do not provide you with equivalent or better separations as compared to any other GC column of the same phase and comparable dimensions, send in your comparative data within 45 days and keep the column for FREE!! Phenomenex has always given superb customer support I changed suppliers from Agilent to Phenomenex based on your customer support about 0 years ago and you have not failed me since that point! Marie Coschigano, Genzyme Corporation Continuing Innovation Zebron s track record of innovation has been recognized with 3 R&D 00 Awards. No other GC columns have received this honor. Your input fuels the research and development of GC products designed specifically to overcome your analytical obstacles share with us at Birth of Zebron GC columns 004 Zebron MS phases 005 ZB-WAXplus 00 % water stable 006 ZB-MultiResidue phases For pesticide screening 007 Zebron Inferno Stable up to 430 C 009 ZB-Drug- ZB-Bioethanol 0 Cool-Lock Nut Patented Technology 0 ZB-SemiVolatiles Improved inertness for SVOCs 04 ZB-CLPesticides Versatility for pesticides by GC/ ECD 05 ZB-5MS PLUS The next generation of inertness 06 Phenomenex, Inc. All rights reserved. Phenomenex l WEB:

3 GC Table Accessories of Contents GC Phase Selection Tips... p. 4 GC Column Dimension Selection Tips... p. 5 GC Column - Phase Selection... p. 6 For General Purpose Wide range of general purpose Zebron phases to suit a variety of applications. Every Zebron GC column is individually QC tested for efficiency, bleed, activity, and retention. Polar Semi-Volatiles ZB-ms... p. 7 ZB-5MSPLUS... p. 8 Non-Polar Volatiles ZB p. ZB-WAXPLUS... p. Other Offerings: ZB-, ZB-5, ZB-5MSi, ZB-35, ZB-50, ZB-70, ZB-70P, ZB-WAX, ZB-FFAP, and ZB-XLB For Specialty Applications Premier Zebron phases specially designed and manufactured to deliver the best results for specific application areas Environmental ZB-SemiVolatiles... pp. 3-4 ZB-MultiResidue &... pp. 5-6 Drugs of Abuse ZB-Drug-... p. 7 Simulated Distillation ZB-XT SimDist Metal... p. 8 Other Offerings: ZB-Bioethanol, ZB-CLPesticides- and - For High Temperatures Robust fused silica columns with long lifetimes for high temperature bake outs up to 430 C Featured Zebron Inferno Phases ZB-HT Inferno... p. 9 ZB-5HT Inferno... p. 0 Other Offerings: ZB-35HT Inferno and ZB-XLB-HT Inferno 3

4 Introducing Zebron GC the Columns Zebron Experience GC Phase Selection Tips Selectivity Has the Biggest Impact on Resolution Resolution between two analytes is mainly determined by the selectivity of the stationary phase. By increasing the resolution between two compounds, the total analysis time can often be reduced significantly! The Master Resolution Equation N x α- x R s = 4 α k k+ Efficiency Term Selectivity Term Retention Term Selectivity vs. Polarity Column polarity and selectivity are often confused polarity gives a general guideline for sample capacity and separation, which can affect peak shape and resolution. However, two columns may have similar polarity but show very different separation profiles because of differences in phase chemistry. ZB-35 (Polarity: 8) ZB-70 (Polarity: 9) C N CH 3 CH 3 Si O Si O Si O (CH ) 3 Si O CH 3 CH 3 65 % Dimethylpolysiloxane 35 % Phenyl 86 % Dimethylpolysiloxane The columns have very similar polarity, but the cyanopropyl group makes ZB-70 very different from ZB-35 in terms of selectivity. 4 % Cyanopropylphenyl The 3 Most Prevalent GC Interactions Dispersive Forces (Van der Waals Interactions) Weakest of all intermolecular forces and occurs between non-polar compounds Separation is based on boiling point (classic example hydrocarbon separation in SimDist analysis) Dipole-Dipole Interactions Either permanently present or induced by analyte-stationary phase interactions Higher dipole-dipole interaction can help separate compounds with similar boiling points, but different chemical structures Hydrogen Bonding (Acid-Base Interactions) Can cause poor peak shape or irreversible binding to the inlet liner or to the column itself 4

5 GC Zebron Accessories GC Columns GC Column Dimension Selection Tips A good starting dimension is 30 meter x 0.5 mm x 0.5 µm. From there, you can tweak individual parameters (column length, ID, and film thickness) depending on the needs of your analysis. Shorter (5 m or less) Recommended For: Sample screening or samples with very few analytes LENGTH 30m Longer (60 m or more) Recommended For: Better separation or complex samples with closely eluting peaks Advantages: Faster run times; higher efficiency separations; good for more chemically active samples and high molecular weight compounds Advantages: Higher resolution as length increases; good for low boilers, less active samples, or complex temperature ramps Disadvantages: Resolution decreases as length decreases Disadvantages: Slow run times Narrower (0.0, 0.8, or 0.0 mm) Recommended For: Faster analysis and complex samples INTERNAL DIAMETER 0.5mm Recommended For: Dirty or highly concentrated samples Wider (0.3 or 0.53 mm) Advantages: Faster run times; better resolution Advantages: Increased sample capacity; good for routine on-column injection Disadvantages: Easily overloaded; lower sample capacity Disadvantages: Decreased efficiency; resolution decreases as ID increases Thinner (0.0 or 0.8 µm) Recommended For: Analysis of high boilers, GC-MS applications Advantages: Higher efficiency; lower bleed; faster run times; higher temperature limits FILM THICKNESS 0.5µm Thicker (0.50 µm or more) Recommended For: Analysis of low boilers, gases, solvents, purgeables, and volatile compounds Advantages: Better inertness; higher capacity Disadvantages: Less inert; limited retention Disadvantages: Slower run times; higher bleed; lower temperature limits 5

6 Introducing Zebron GC the Columns Zebron Experience GC Column - Phase Selection Learn even more about Zebron GC column phases and applications at Polarity Phase Composition Temperature Limits (Isothermal/TPGC) MS Certified 5 ZB- 00 % Dimethylpolysiloxane -60 to 360/370 C* 3 5 ZB-ms 00 % Dimethylpolysiloxane -60 to 360/370 C 3 5 ZB-HT Inferno 00 % Dimethylpolysiloxane -60 to 400/430 C** 3 5 ZB-XT SimDist 00 % Dimethylpolysiloxane -60 to 450 C* 3 8 ZB-5 95 % Dimethylpolysiloxane 5 % Phenyl 8 ZB-5ms 95 % Dimethylpolysiloxane 5 % Phenyl-Arylene 8 ZB-5MSi 95 % Dimethylpolysiloxane 5 % Phenyl 5% Pheyl-Arylene 8 ZB-5MSplus 95% Dimethylpolysiloxane 8 ZB-5HT Inferno 95 % Dimethylpolysiloxane 5 % Phenyl 8 ZB-SemiVolatiles 95 % Dimethylpolysiloxane 5 % Phenyl-Arylene -60 to 360/370 C* 3-60 to 35/350 C 3-60 to 360/370 C 3-60 to 35/350 C 3-60 to 400/430 C** 3-60 to 35/350 C 3 9 ZB-XLB Proprietary 30 to 340/360 C* 3 9 ZB-XLB-HT Inferno Proprietary 30 to 400 C 3 ZB-MultiResidue - Proprietary -60 to 30/340 C 3 3 ZB % Dimethylpolysiloxane 6 % Cyanopropylphenyl -0 to 60 C 5 ZB-MultiResidue- Proprietary -60 to 30/340 C 3 8 ZB % Dimethylpolysiloxane 35 % Phenyl 8 ZB-35-HT Inferno 65 % Dimethylpolysiloxane 35 % Phenyl 9 ZB % Dimethylpolysiloxane 4 % Cyanopropylphenyl 9 ZB-70P 86 % Dimethylpolysiloxane 4 % Cyanopropylphenyl 4 ZB % Dimethylpolysiloxane 50 % Phenyl 40 to 340/360 C 3 40 to 400 C 3-0 to 80/300 C* -0 to 80/300 C* 40 to 30/340 C 3 5 ZB-WAXplus 00 % Polyethylene Glycol 0 to 50/60 C* 57 ZB-WAX 00 % Polyethylene Glycol 40 to 50/60 C 3 58 ZB-FFAP Nitroterephthalic Acid Modified Polyethylene Glycol PHENOMENEX ~exclusive~ 40 to 50/60 C ZB-CLPesticides- & Proprietary 40 to 30/340 C ZB-BAC & Proprietary 40 to 30/340 C 3 ZB-Drug- Proprietary -0 to 60/80 C 3 ZB-Bioethanol Proprietary -60 to 340/360 C 3 Need help selecting a column? Ask a GC specialist at Recommended Applications Amines, Drugs, Essential Oils, Ethanol, Gases (Refinery), Hydrocarbons, Mercaptans, MTBE, Natural Gas Odorants, Oxygenates and GROs, PCBs, Pesticides, Semi-volatiles, Simulated Distillation, Solvent Impurities, Sulfur Compounds (Light) Acids, Amines, Diesel Fuel, Drugs, Flavors & Fragrances, PCBs (EPA Method 668), Pesticides Diesel Fuel, High Boiling Petroleum Products, High Molecular Weight Waxes, Long-chained Hydrocarbons, Motor Oils, Polymers/Plastics, Simulated Distillation ASTM Methods (D887, D887X, D370, D635, D769), Crude Oil, Gasoline Fractions, Petroleum Distillates, Petroleum Fractions, Simulated Distillation, Vacuum Distillates Alkaloids, Dioxins, Drugs, Essential Oils/Flavors, FAMEs, Halo-hydrocarbons, PCBs/Aroclors, Pesticides/Herbicides, Phenols, Residual Solvents, Semi-volatiles Acids, Alkaloids, Amines, Dioxins, Drugs, Essential Oils/Flavors, FAMEs, Halo-hydrocarbons, PCBs/Aroclors, Pesticides/Herbicides, Phenols, Residual Solvents, Semi-volatiles, Solvent Impurities Drugs, EPA Methods, FAMEs, Nitrosamines, Pesticides, Phenols Acids, Alkaloids, Amines, Drugs, Essential Oils/ Flavours, Halo-hydrocarbons, Phenols, Residual Solvents, Solvent Impurities, Pesticides/ Herbicides Diesel Fuels, High Boiling Petroleum Products, High Molecular Weight Waxes, Long-chained Hydrocarbons, Motor Oils, Polymers/Plastics, Simulated Distillation, Surfactants, Triglycerides Acids, Alkaloids, Amine, Dioxins, Drugs, EPA Methods (55, 60, 65, 800, 870D), Halogentaed Hydrocarbons, PCB/Aroclors, Pesticides/Herbicides, Phenols, Residual Solvents, SemiVolatiles PCBs, Pesticides/Herbicides EPA Methods, PCBs, Pesticides/Herbicides Aroclors/PCBs, Haloacetic Acids, Herbicides, Insecticides, Multi-Pesticide Screening, Nitrogen Containing Pesticides, Organochlorine Pesticides, Organophosphorous Pesticides EPA Methods (50.3, 50., 503., 54., 60, 60, 64, 800, 805, 800, 80, 840, 860), Pharmaceuticals, Residual Solvents, Volatile Organic Compounds (VOCs) Aroclors/PCBs, Haloacetic Acids, Herbicides, Insecticides, Multi-Pesticide Residue/Screening, Nitrogen Containing Pesticides, Organochlorine Pesticides, Organophosphorous Pesticides Amines, Aroclors, Drugs, EPA Methods (508, 608, 808, 84, 85), Pesticides, Pharmaceuticals, Semi-volatiles, Steroids Amines, Aroclors, Chemicals, Drugs, EPA Methods (508, 608, 808, 84, 85), Pesticides, Pharmaceuticals, Semi-volatiles, Steroids Alcohols, Amines, Aromatic Hydrocarbons, Drugs, Esters, PAHs, PCBs, Pharmaceutical Intermediates, Phenols, Solvents, Steroids, TMS Sugars, Tranquilizers Aroclors, Nitrogen Containing Pesticides, Organochlorine Pesticides, Organophosphorous Pesticides Antidepressants, Aroclors, Cholesterols, Drugs of Abuse, EPA Methods (508, 608, 808, 84, 85), Glycols, Pesticides/Herbicides, Steroids, Triglycerides Alcohols, Aldehydes, Aromatics, Essential Oils, Flavors & Fragrances, Free Fatty Acids, Glycols, OVIs, Pharmaceuticals, Solvents / Residual Solvents, Styrene, Xylene Isomers Alcohols, Aldehydes, Aromatics, Basic Compounds, Essential Oils, Flavors & Fragrances, Glycols, Pharmaceuticals, Solvents, Styrene, Xylene Isomers Acrylates, Alcohols, Aldehydes, Free Fatty Acids, Ketones, Organic Acids, Phenols, Volatile Free Acids Dual-column chlorinated pesticide EPA Methods (808 and 808 extended, 808, 85, 504, 505, 508,55) Abused Inhalant Anesthetics, Blood Alcohol Analysis Drug Screening (6-MAM, Amphetamines, Barbiturates, Benzodiazepines, Opiates, PCP, THC) Alcohol, Bioethanol, Fusel Alcohols 6 * Thicker films (.0 µm df) are rated to lower Isothermal/TPGC limits for this phase. ** 0.53 mm ID dimensions are rated to lower max operational temperature for this phase. For specific temperature limits for your phase, visit or contact your GC Specialist.

7 GC Zebron Accessories GC Columns ZB-ms Very low bleed (MS Certified) phase especially suited to high sensitivity GC/MS Column Profile Low High Extremely inert for active compounds such as drugs, pesticides, or acids and bases Improved signal-to-noise ratio for better sensitivity and mass spectral integrity 5 Polarity Bleed Temperature Limits Identical selectivity to the ZB- Stability Equivalent to USP Phase G Temperature Limits: -60 to 360/370 C (Isothermal/TPGC) Applications Amines Acids Diesel Fuel Polychlorinated Biphenyls (EPA Method 668) Drugs of abuse Flavors & Fragrances Pesticides Lower Overall Column Activity Activity is a key measure of column quality. This is why Zebron ZB-ms columns are aggressively tested to ensure full deactivation. Below is an example of the aggressive QC test mix we use, notice the low tailing for even the most active compounds like -Ethylhexanoic Acid! Alternative to Any MS-Certified 00 % Dimethylpolysiloxane Phase: DB-ms HP-ms AT-ms MDN- Rtx-MS VF-ms SolGel-ms Equity- CP-Sil 5 CB ms Test Conditions for Zebron ZB-ms Column: Zebron ZB-ms Dimensions: 30 meter x 0.5 mm x 0.5 µm Part No.: 7HG-G0- Injection: Split 50 C,.0 µl Carrier Gas: ml/min (constant flow) Oven Program: 40 C (Isothermal) Detector: 35 C Sample:. Decane. -Ethylhexanoic Acid 3. 4-Chlorophenol 4. Naphthalene 5. Tridecane 6. -Undecanol 7. Dicyclohexylamine 8. Pentadecane ZB-ms Test Mix 5 0 min Part No.: AG App ID 5545 Zebron ZB-ms GC Columns ID(mm) df(µm) Temp. Limits C Part No. 0-Meter to 360/370 7CB-G to 360/370 7CD-G0-08 -Meter to 360/370 7DE-G0-4 5-Meter to 360/370 7EG-G to 360/370 7EM-G0-0-Meter to 360/370 7FD-G to 360/370 7FD-G0-5-Meter to 360/370 7GE-G Meter to 360/370 7HG-G to 360/370 7HG-G to 360/370 7HG-G to 360/370 7HG-G to 360/370 7HM-G to 360/370 7HM-G to 360/370 7HK-G0-60-Meter to 360/370 7KG-G to 360/370 7KG-G to 360/370 7KM-G0- Note: If you need a 5 in. cage, simply add a (-B) after the part number, e.g., 7HG- G0--B. Some exceptions may apply. Agilent 6850 and some SRI and process GC systems use only 5 in. cages. 7

8 Introducing Zebron GC the Columns Zebron Experience ZB-5MSplus The next generation of inertness for specialty chemical, forensic, toxicology, and food testing applications Specialized deactivation for versatile 5% Phenyl-Arylene selectivity with improved sensitivity Low bleed (MS Certified) and well-suited to high sensitivity GC/MS and GC/MS/MS work Equivalent to USP Phase G7 Temperature Limits: -60 to 35/350 C Column Profile Low Polarity Bleed Temperature Limits Stability 8 High Zebron ZB-5MS PLUS Better peak shapes with no retention time shifts! Applications Acids Alkaloids Amines Drugs Essential Oils/Flavors Halo-hydrocarbons Phenols Residual Solvents Solvent Impurities Pesticides/Herbicides Upgrade from Any 5 % Phenyl or 5 % Phenyl -Arylene 95 % Dimethylpolysiloxane Phase: DB -5ms HP -5ms Rxi -5Sil MS DB-5ms Ultra Inert HP-5ms Ultra Inert SLB -5ms DB-5.65 VF-5ms Traditional 5ms Phase App ID 348 min App ID 349 min Zebron ZB-5MSPLUS GC Columns ID(mm) df(µm) Temp. Limits C Part No. 5-Meter to 35/350 7EG-G030-0-Meter to 35/350 7FD-G to 35/350 7FD-G Meter to 35/350 7HG-G to 35/350 7HG-G to 35/350 7HG-G to 35/350 7HM-G to 35/350 7HM-G Meter with 5-Meter Guardian Integrated Guard to 35/350 7HG-G030--GGA 30-Meter with 0-Meter Guardian Integrated Guard to 35/350 7HG-G030--GGC to 35/350 7HG-G030-7-GGC 60-Meter to 35/350 7KG-G030- Conditions for both columns: Column: As listed Dimensions: 30 meter x 0.5 mm x 0.5 µm Injection: Split 50 C, µl Carrier Gas: ml/min (constant flow) Oven Program: 40 C (Isothermal) Detector: 35 C Sample:. m-xylene. o-xylene 3. Decane 4. -Ethylhexanoic Acid 5.,6-Hexanediol 6. 4-Chlorophenol 7. Tridecane 8. -Methylnaphthalene 9. -Undecanol 0. Tetradecane. Dicyclohexylamine. Pentadecane ZB-5MSPLUS Test Mix Part No.: AG0-90 Want better peak shape for acidic/basic compounds, drugs of abuse, and pesticides? Try the highly inert and low bleed ZB-5MSi 8

9 GC Zebron Accessories GC Columns ZB-HT Inferno 007 R&D 00 Award Recipient First non-metal columns stable to 430 C Provides true boiling point separation for hydrocarbon distillation methods Longer lifetime with rugged high temperature, polyimide coated, fused silica tubing Low activity, provides good peak shape for acidic and basic samples Provides robust column performance for high temperature bake outs Individually tested for low bleed, MS certified Temperature Limits: -60 to 400/430 C (Isothermal/TPGC)* Column Profile Low Polarity Bleed Temperature Limits Stability 5 Applications High Boiling Petroleum Products Simulated Distillation Methods Long-chained Hydrocarbons High Molecular Weight Waxes Polymers/Plastics Motor Oils Diesel Fuel High Hydrocarbons from Water: DIN EN ISO (DEV H53) Alternative to Any 00 % Dimethylpolysiloxane High Temperature Phase: DB-ht Petrocol 887 CP-SimDist Rxi -HT min Column: Zebron ZB-HT Inferno Dimensions: 5 meter x 0.3 mm x 0.5 μm Part No.: 7EM-G04- Injection: 300 C, 0 μl Carrier Gas: ml/min (constant flow) Oven Program: 50 C for min to C/min for 5 min Detector: 330 C Sample:. Decane. Tetracontane App ID 853 Zebron ZB-HT Inferno GC Columns ID(mm) df(µm) Temp. Limits C Part No. 5-Meter to 400/430 7AK-G Meter to 400/430 7CM-G04-5-Meter to 400/430 7EG-G to 400/430 7EG-G to 400/430 7EM-G to 400/430 7EM-G to 400 7EK-G Meter to 400/430 7FD-G Meter to 400/430 7HG-G to 400/430 7HG-G to 400/430 7HM-G to 400/430 7HM-G to 400 7HK-G04-05 Note: If you need a 5 in. cage, simply add a (-B) after the part number, e.g., 7HG- G04--B. Some exceptions may apply. Agilent 6850 and some SRI and process GC systems use only 5 in. cages. ZB-HT Test Mix Part No.: AG0-555 Courtesy of Dr. Alexander Ruderisch, Agrolab Labor GmbH, Bruckberg *0.53 mm ID columns are rated to 400 C max operational temperature. 9

10 Introducing Zebron GC the Columns Zebron Experience ZB-5HT Inferno 007 R&D 00 Award Recipient 0 First non-metal columns stable to 430 C Robust column for high temperature bake outs analysis, such as biodiesel, long-chain hydrocarbons, polymers, and high molecular weight compounds Provides true boiling point separation for hydrocarbon distillation methods Longer lifetime with rugged high temperature, polymide coated, fused silica tubing Low activity, provides good peak shape for acidic and basic samples Individually tested for low bleed, MS certified Temperature Limits: -60 to 400/430 C (Isothermal/TPGC)* Lower Bleed!* pa Zebron ZB-5HT Inferno Agilent J&W DB-5ht min Conditions for all columns**: Dimensions: 30 meter x 0.5 mm x 0.0 μm Injection: Null 50 C Carrier Gas: psi (Constant Pressure) Oven Program: 0 C for 3 min to C/min (hold 5 min) to C/min (hold 5 min) to C/min (hold 5 min) to C/min (hold 5 min) to C/min (hold 5 min) Detector: 405 C How does the lifetime test work? Hydrocarbons are a good way to measure the stability and lifetime of a non-polar column. Because its interaction with the phase is mostly based on London Dispersion forces, any change in retention time is correlated with phase loss. This will result in increased bleed and poor reproducibility. In the lifetime study above, the Zebron ZB-5HT Inferno column has twice the lifetime as the two comparative columns. For the test, all columns were held at 400 C for hours and then the oven was lowered to 0 C for Pentadecane analysis. The Varian HT column broke just after 40 hours at 400 C. The Agilent J&W DB- 5ht column had the same retention for Pentadecane at 40 hours as the ZB-5HT at 00 hours. *The shaded area depicts the bleed criteria for MS certified columns on a MS detector. MS bleed certification values are typically read at 30 ºC. This demonstrates the low bleed capabilities of the ZB-5HT. It meets MS certification limits even at 360 ºC! **All columns used for above tests were new/never used, prior to this testing and purchased either directly from the original manufacturer or through an authorized distributor. All testing was carefully controlled to ensure conditions were similar for all columns involved. The comparative data may not be representative of every application. Column Profile Low Polarity Bleed Temperature Limits Stability Zebron Inferno Columns Win In The Lifetime Test Retention of Pentadecane at 0 C (min) Comparison of retention of Pentadecane between the Zebron ZB-5HT Inferno column versus a traditional 5 %-Phenyl - 95 %-dimethylpolysiloxane column. Note that the 5 %-Phenyl column died around 40 hours at 400 C whereas the Zebron ZB-5HT Inferno column maintained great retention of Pentadecane over 00 hours Hours at 400 C Conditions for all columns**: Dimensions: 30 meter x 0.5 mm x 0.0 μm Injection:.0 μl of test mix AG Carrier Gas: ml/min (constant flow) Oven Program: 0 C Isothermal Detector: Flame Ionization Detector 400 C Sample: Pentadecane Zebron ZB-5HT Inferno Agilent J&W DB-5ht Varian VF-5ht Zebron ZB-5HT Inferno GC Columns ID(mm) df(µm) Temp. Limits C Part No. 0-Meter with -Meter Spliced Guard (0.53 mm ID) to 400/430 7CM-G05-0-GST 5-Meter to 400/430 7EG-G to 400/430 7EG-G to 400/430 7EM-G to 400/430 7EM-G to 400 7EK-G Meter with -Meter Spliced Guard (0.53 mm ID) to 400/430 7EM-G05-0-GST 0-Meter to 400/430 7FD-G Meter to 400/430 7HG-G to 400/430 7HG-G to 400/430 7HM-G to 400/430 7HM-G to 400 7HK-G Meter to 400/430 7KG-G05- Note: If you need a 5 in. cage, simply add a (-B) after the part number, e.g., 7HG-G05- -B. Some exceptions may apply. Agilent 6850 and some SRI and process GC systems use only 5 in. cages. ZB-5HT Test Mix Part No.: AG0-555 *0.53 mm ID columns are rated to 400 C max operational temperature. Agilent and J&W are registered trademarks of Agilent Technologies, Inc. Varian is a registered trademark under license to Agilent Technologies, Inc. High

11 GC Zebron Accessories GC Columns ZB-64 Widely used phase to separate volatile organic flavor and fragrance additives and residual solvents in industrial or pharmaceutical products (OVIs) Popular choice for residual solvent testing Excellent for US EPA Methods 50.3, 50., 503., 54., 60, 60, 64, 800, 805, 800, 80, 840, 860 Specifically designed for the separation of volatile organic compounds (VOCs) Increased temperature limit speeds run times and re-equilibration Equivalent to USP Phase G43 Temperature Limits: -0 to 60 C Column Profile Low Polarity Bleed Temperature Limits Stability 3 Applications Volatile Organic Compounds (VOCs) Residual Solvents EPA Methods 50.3, 50., 503., 54., 60, 60, 64, 800, 805, 800, 80, 840, 860 Pharmaceuticals High USP <467>: Residual Solvents Procedure A - Class 4 Alternative to Any 6 %-Cyanopropylphenyl- 94 %-Dimethylpolysiloxane Phase: DB-64 AT-64 DB-VRX Rtx-30 CP-30 Rtx-64 BP HP-VOC DB-30 SPB-30 CP-Select 64 CB SPB-64 Rtx-VMS min Column: Zebron ZB-64 Dimensions: 30 meter x 0.3 mm x.80 µm Part No.: 7HM-G005-3 Injection: Split 40 C, ml Carrier Gas: 35 cm/sec (constant flow) Oven Program: 40 C for 0 min to 40 0 C/min for 0 min Detector: 50 C Sample:.,-Dichloroethene.,,-Trichloroethane 3. Carbon tetrachloride 4. Benzene 5.,-Dichloroethane 3 5 App ID 6348 Zebron ZB-64 GC Columns ID(mm) df(µm) Temp. Limits C Part No. 0-Meter to 60 7FD-G Meter to 60 7HG-G to 60 7HM-G to 60 7HK-G Meter to 60 7KG-G to 60 7KM-G to 60 7KK-G Meter to 60 7LK-G Meter to 60 7NK-G Note: If you need a 5 in. cage, simply add a (-B) after the part number, e.g., 7HM- G005-3-B. Some exceptions may apply. Agilent 6850 and some SRI and process GC systems use only 5 in. cages. ZB-64 Test Mix Part No.: AG0-559

12 Introducing Zebron GC the Columns Zebron Experience ZB-WAXplus 00 % aqueous stable, excellent for aqueous samples Extremely inert for acidic compounds Enhanced selectivity for low boiling solvents High retention of alcohols and chlorinated solvents Increased efficiency at 0 C Bonded and solvent rinsible Equivalent to USP Phase G6 Temperature Limits: 0 to 50/60 C (Isothermal/TPGC)* Enhanced Aqueous Stability for Polar Compounds Wax columns provide optimal selectivity for many aqueous soluble compounds such as those found in alcoholic beverages or glycol samples. Historically, Polyethylene Glycol (PEG) phases have been unstable with aqueous samples resulting in poor reproducibility and decreased lifetime. The ZB-WAXplus bonding procedure results in exceptional stability to repeated injections of aqueous matrices. Water Reproducibility of ZB-WAXPLUS pa Column: Zebron ZB-WAXplus Dimensions: 30 meter x 0.5 mm x 0.5 µm Part No.: 7HG-G03- Injection: Split 40 C, 0. µl Carrier Gas: ml/min (constant flow) Oven Program: 35 C for 5 min to 85 0 C/min to 00 5 C/min for min Detector: 00 C Sample:. Acetaldehyde. Ethyl Acetate 3. Methanol 4. Ethanol 5. Propanol 6. Isobutanol 7. -Methylbutanol 8. 3-Methylbutanol 6 7,8 Scottish Single Malt Whiskey 60% Aqueous! min App ID 587 Column Profile Low Polarity Bleed Temperature Limits Stability Applications Alcoholic Beverages Alcohols OVIs Aldehydes Aromatics Alternative to Any Polyethylene Glycol Phase: DB-WAX PEG 0M HP-0M Stabilwax Acids (free) Essential oils Flavors / Fragrances Styrene Glycols SUPELCOWAX-0 AT-WAX CP-WAX 5 CB AT-AquaWax 5 Pharmaceuticals Solvents Xylene Isomers High Carbowax 0M Permabond CW 0M CAM BP0 Zebron ZB-WAXPLUS GC Columns ID(mm) df(µm) Temp. Limits C Part No. 0-Meter to 50/60 7CB-G Meter to 50/60 7EG-G to 30/40 7EK-G03-0-Meter to 50/60 7FD-G Meter to 50/60 7HG-G to 50/60 7HG-G to 50/60 7HM-G to 50/60 7HM-G to 30/40 7HM-G to 30/40 7HK-G03-60-Meter to 50/60 7KG-G to 50/60 7KG-G to 50/60 7KG-G to 50/60 7KM-G to 50/60 7KM-G to 30/40 7KK-G03- Note: If you need a 5 in. cage, simply add a (-B) after the part number, e.g., 7HG- G03--B. Some exceptions may apply. Agilent 6850 and some SRI and process GC systems use only 5 in. cages. ZB-WAXplus Test Mix Part No.: AG *Thicker films (.0 µm df) are rated to 30/40 C (Isothermal/TPGC).

13 GC Zebron Accessories GC Columns ZB-SemiVolatiles Specifically designed to overcome obstacles for sensitive semi-volatile methods Column Profile Low High Enviro-Inert Technology provides a rugged 5 %-Phenyl- Arylene phase improve inertness without compromising selectivity Polarity Bleed 8 Rugged QC test includes EPA 870 tuning standard to ensure column is ready to pass suitability requirements Temperature Limits Stability Low bleed (MS Certified) especially suited to high sensitivity work using GC/MS Applications Our column of choice for EPA Methods 55, 60, 65, 800, and 870 Temperature Limits: -60 to 35/350 C Acids Alkaloids Amine Dioxins Drugs EPA Methods (55, 60, 65, 800, 870D) Halogentaed Hydrocarbons PCB/Aroclors Pesticides/Herbicides Phenols Residual Solvents SemiVolatiles Upgrade from Any 5%-Phenyl or 5%-Phenyl -Arylene-95%- Dimethylpolysiloxane Phase: DB-5ms HP-5ms Rxi-5ms DB-5ms Ultra Inert HP-5ms Ultra Inert Rxi-5Sil MS DB-5.65 VF-5ms CP-Sil 8 CB MS You Spoke, You Tested, You Approved Your input fueled the research and development of Zebron ZB-SemiVolatiles the column specifically designed to overcome your EPA Method 870D obstacles. Several environmental labs have verified real-world performance on ZB-SemiVolatiles: We QC Test for the SVOC Compounds You Analyze We take the guesswork out of meeting method requirements by aggressively testing ZB-SemiVolatiles with two different test mixes. We incorporated troublesome analytes from your samples (Pyridine) and compounds in the 870D tuning standard (DDT, Pentachlorophenol, and Benzidine) into our QC test, so you can be sure your column is ready to meet suitability requirements for the method. TestAmerica Laboratories, Inc. Buffalo Phoenix Environmental Laboratories, Inc. Other labs like yours! Real Customer Results For EPA Method 870D on ZB-SemiVolatiles Pyridine (PYR) Very active amine exposes any basic activity EPA 870D Requirement Our Requirement Peak Response: Not Specified 0.6* Pentachlorophenol (PCP) PCP peaks disappear and exhibit tailing on columns with acid activity EPA 870D Requirement Our Requirement Peak Skew:.0.0 Peak Response: Not Specified 0.3 Benzidine Active amine that tails when basic activity is present EPA 870D Requirement Our Requirement Peak Skew:.0.0 Zebron ZB-SemiVolatiles is a very stable and durable semivolatile column. This has reduced TestAmerica s downtime and increased our productivity, enabling us to better serve our clients needs. DDT Breaks down in an active system to DDE & DDD EPA 870D Requirement Our Requirement Breakdown: < 0 % < 0 % *Requirement of 0.5 for 60 m x 0.5 mm x 0.5 µm and 0 m Guardian dimensions The opinions stated herein are solely those of the speaker and not necessarily those of any company or organization. 3

14 Introducing Zebron GC the Columns Zebron Experience min min ZB-SemiVolatiles (cont d) Great Resolution of Key Critical Pairs and Improved Peak Shapes Enviro-Inert technology allows Zebron ZB-SemiVolatiles to provide improved productivity with shorter run times for EPA 870D, while maintaining resolution of key critical pairs. Full Separation Good Peak Shape min min min EPA Method 870D: Semi-volatile Organic Compounds min.5 min min..3 N-Nitrosodimethylamine and Pyridine,4-Dinitrophenol App ID 058 Valley Height = 9.9 % 870D Requires 50 % BOX THAT IS " TALL BY.6" WIDE (USED AS TEMPLATE) Valley Height = 0.9 % 870D Requires 50 % min min min min min.7.9 min min Benzo[b]fluoranthene and Benzo[k]fluoranthene Indeno[,,3-cd]pyrene and Dibenz[a,h]anthracene, both share mass 76 BOX THAT IS " TALL BY.6" WIDE (USED AS TEMPLATE) min min min Real Customer Sample for EPA Method 870D Zebron ZB-SemiVolatiles GC Columns ID (mm) df (µm) Temperature Limits ( C) Part No. 5-Meter to 35/350 7EG-G to 35/350 7EG-G Meter to 35/350 7FD-G to 35/350 7FD-G Meter to 35/350 7HG-G to 35/350 7HG-G Meter with 5-Meter Guardian Integrated Guard to 35/350 7HG-G07--GGA to 35/350 7HG-G07-7-GGA 30-Meter with 0-Meter Guardian Integrated Guard to 35/350 7HG-G07--GGC to 35/350 7HG-G07-7-GGC 60-Meter to 35/350 7KG-G07- BOX THAT IS " TALL BY.6" WIDE (USED AS TEMPLATE) The opinions stated herein are solely those of the speaker and not necessarily those of any company or organization. 4

15 GC Zebron Accessories GC Columns ZB-MultiResidue - and - exclusive Proprietary phase specially designed for the separation of all types of pesticides, herbicides, and insecticides Column Profile Low High Provides baseline resolution and confirmation of all 0 chlorinated pesticides regulated under EPA Method 808 in 0 min Polarity MR- Polarity MR- 5 Low activity, decreased breakdown of sensitive pesticides such as DDT Bleed Temperature Limits Provides robust column performance for high temperature bake outs MS Certified phases provide low bleed performance for pesticide confirmation by MS Temperature Limits: -60 to 30/340 C (Isothermal/TPGC) Stability Applications Organochlorine Pesticides Insecticides Organophosphorous Pesticides Aroclors/PCBs Nitrogen Containing Pesticides Haloacetic Acids Herbicides Multi-pesticide Residue Methods Similar* to: Rtx-CLPesticides Rtx-CLPesticides Stx-CLPesticides Stx-CLPesticides *not exact equivalent, selectivity might be different EPA Methods 508 and 808A A , , , 0 9, , Baseline Resolution of EPA Method 808 MR App ID 680 B , 9,0 MR App ID min min Column: A) Zebron MultiResidue- B) Zebron MultiResidue- Dimensions: A) 30 meter x 0.3 mm x 0.5 µm B) 30 meter x 0.3 mm x 0.50 µm Part No.: A) 7HM-G07- B) 7HM-G06-7 Injection: 3 C, µl Carrier Gas: ml/min (constant flow) Oven Program: 0 C for 0.5 min to 0 30 C/min to C/min for min Detector: 340 C Sample: All analytes are 50 ppb in isooctane. DBCP. Hexachlorocyclopentadiene 3. Etridiazole 4. Chloroneb 5. Propachlor 6. Diallate 7. a-bhc 8. Hexachlorobenzene 9. g-bhc 0. b-bhc. Dichlone. Alachlor 3. d-bhc 4. Chlorothalonil 5. Heptachlor 6. DCPA (Dacthal) 7. Aldrin 8. Heptachlor epoxide 9. Captan 0. trans-chlordane (gamma). cis-chlordane (alpha). trans-nonachlor 3. Endosulfan I 4. DDE 5. Dieldrin 6. Chloropropylate 7. Chlorobenzilate 8. Endrin 9. Nitrofen 30. DDD 3. Endosulfan II 3. Kepone 33. Trithion 34. Endrin aldehyde 35. DDT 36. Endosulfan sulfate 37. Captafol 38. Methoxychlor 39. Endrin ketone 40. Permethrin 4. Permethrin isomer Well-suited for Dual Column Analysis Injector 5 m Z-Guard Zebron MR- Zebron MR- Y-Splitter ECD Detector ECD Detector 5

16 Introducing Zebron GC the Columns Zebron Experience ZB-MultiResidue - and - (cont d) Zebron ZB-MultiResidue GC Columns (MR)- ID(mm) df(µm) Temp. Limits C Part No. 0-Meter to 30/340 7FD-G Meter to 30/340 7HG-G to 30/340 7HM-G to 30/340 7HM-G to 30/340 7HK-G06-7 Zebron ZB-MultiResidue GC Columns (MR)- ID(mm) df(µm) Temp. Limits C Part No. 30-Meter to 30/340 7HG-G to 30/340 7HM-G to 30/340 7HK-G07-7 Note: If you need a 5 in. cage, simply add a (-B) after the part number, e.g., 7HG-G06- -B or 7HG-G07-0-B. Some exceptions may apply. Agilent 6850 and some SRI and process GC systems use only 5 in. cages. ZB-MultiResidue Column Kits 0.5 mm ID (kit consists of products below) Part No.: KG0-837 Description Dimension Part No. MultiResidue MR- Column 30 meter x 0.5 mm x 0.5 µm df 7HG-G06- MultiResidue MR- Column 30 meter x 0.5 mm x 0.0 µm df 7HG-G07-0 Z-Guard 5 meter x 0.5 mm 7AG-G GZ0 Universal Capillary Column Y-connector, Fused Quartz AG mm ID (kit consists of products below) Part No.: KG0-838 Description Dimension Part No. MultiResidue MR- Column 30 meter x 0.3 mm x 0.50 µm df 7HM-G06-7 MultiResidue MR- Column 30 meter x 0.3 mm x 0.5 µm df 7HM-G07- Z-Guard 5 meter x 0.3 mm 7AM-G GZ0 Universal Capillary Column Y-connector, Fused Quartz AG mm ID (kit consists of products below) Part No.: KG0-839 Description Dimension Part No. MultiResidue MR- Column 30 meter x 0.53 mm x 0.50 µm df 7HK-G06-7 MultiResidue MR- Column 30 meter x 0.53 mm x 0.50 µm df 7HK-G07-7 Z-Guard 5 meter x 0.53 mm 7AK-G GZ0 Universal Capillary Column Y-connector, Fused Quartz AG

17 GC Zebron Accessories GC Columns Zebron ZB-Drug- exclusive 009 R&D 00 Award Recipient Optimized phase for the separation of drugs of abuse Provides fast analysis with great peak shape Improves resolution of target analytes from matrix interferences Specially deactivated to improve quantitation for drug compounds Temperature Limits: 40 to 30/340 C Applications Drugs of Abuse Opiates on a ZB-5ms 3,4 Opiates on a ZB-Drug-, Unique Selectivity for Drugs 3,4 App ID 6733 App ID min Column: Zebron ZB-5ms Dimensions: 0 meter x 0.8 mm x 0.8 µm Part No.: 7CD-G00-08 Injection: Split 40 C, µl Carrier Gas: ml/min (constant flow) Oven Program: 40 C to 30 0 C for min Detector: 30 C Sample: 0 pppm BSTFA/Pyridine. Codeine-d6. Codeine 3. Morphine-d3 4. Morphine min Column: Zebron ZB-Drug- Dimensions: 0 meter x 0.8 mm x 0.8 µm Part No.: 7CD-G03-08 Injection: Split 80 C, µl Carrier Gas: 55 cm/sec (constant flow) Oven Program: 80 C to C/min Detector: 30 C Sample: 0 pppm BSTFA/Pyridine. Codeine-d6. Codeine 3. Morphine-d3 4. Morphine Amphetamines App ID 7809 Zebron ZB-Drug- GC Columns ID(mm) df(µm) Temp. Limits C Part No. 0-Meter to 30/340 7CD-G Meter to 30/340 7EG-G03-30-Meter to 30/340 7HG-G03- Note: If you need a 5 in. cage, simply add a (-B) after the part number, e.g., 7HG- G03--B. Some exceptions may apply. Agilent 6850 and some SRI and process GC systems use only 5 in. cages min Column: Zebron ZB-Drug- Dimensions: 0 meter x 0.8 mm x 0.8 µm Part No.: 7CD-G03-08 Injection: Split 80 C, 0. µl Carrier Gas: 55 cm/sec (constant flow) Oven Program: 70 C to 30 0 C/min to ºC/min Detector: 30 C Sample: Analytes are 40 ppm derivatized with HFBA. Amphetamine-d 6. MDA. Amphetamine 7. MDMA-d5 3. Methamphetamine-d4 8. MDMA 4. Methamphetamine 9. MDEA-d5 5. MDA-d5 0. MDEA ZB-Drug- Test Mix Part No.: AG

18 Introducing Zebron GC the Columns Zebron Experience ZB-XT SimDist Metal New Glass Infusion technology provides higher efficiency and greater column-to-column reproducibility Guaranteed high quality - every column is individually tested Up to 70% more efficiency than other columns Improved resolution of C50/C5 Increased accuracy for high temperature simulated distillation analysis Temperature Limits: -60 to 450 C (Isothermal/TPGC)* Hydrocarbons C7 C00+: ASTM Method D769 Column Profile Low Polarity Bleed Temperature Limits Stability 5 Applications Crude Oil Vacuum Distillates Petroleum Distillates Petroleum Fractions Gasoline Fractions Simulated Distillations ASTM Methods D887, D887X, D370, D635, D769 High C7 C8 C9 High Efficiency! Resolution: 4.8 Alternative to: Varian CP-SimDist UltiMetal Restek MXT -HT SimDist Agilent J&W DB-HT Sim Dis C70 C80 C90 C00 App ID 964 C60 C44 C5 C min Column: Zebron ZB-XT SimDist Dimensions: 5 meter x 0.53 mm x 0.5 µm Part No.: 7AK-G06-05 Injection: 33 C, µl Carrier Gas: 7 ml/min (constant flow) Oven Program: 30 C to C/min for 0 min Detector: 450 C Sample: C7 to C44 hydrocarbons and POLYWAX 655 Note: Sample in CS. Chromatogram is baseline subtracted. Zebron ZB-XT SimDist Metal ID(mm) df(µm) Temp. Limits C Part No. 5-Meter to 450 7AK-G to 450 7AK-G Meter to 450 7CK-G to 450 7CK-G to 400 7CK-G Meter to 450 7EK-G06- If you need a 5 in. cage, simply add a (-B) after the part number, e.g., 7CK-G06-05-B. Some exceptions may apply. Agilent 6850 and some SRI and process GC systems use only 5 in. cages. ZB-XT SimDist Test Mix Part No.: AG *Thicker film (.65 µm df) is rated to 400 C (Isothermal/TPGC). 8

19 GC Accessories Don t Forget Your GC Accessories! Including: Liners Septa Ferrules Syringes Unions And Test Mixes Discover the full range of GC Accessories available from Phenomenex at Learn More Online! Get full access to the newest GC products, applications, and technical resources! 9

20 GC Columns For additional GC columns, resources, and applications, visit Australia t: +6 (0) f: +6 (0) Austria t: +43 (0) f: +43 (0) Belgium t: +3 (0) (French) t: +3 (0) (Dutch) f: +3 (0) beinfo@phenomenex.com Canada t: + (800) f: + (30) info@phenomenex.com China t: +86 (0) f: +86 (0) chinainfo@phenomenex.com Denmark t: f: nordicinfo@phenomenex.com Finland t: +358 (0) f: nordicinfo@phenomenex.com France t: +33 (0) f: +33 (0) franceinfo@phenomenex.com Germany t: +49 (0) f: +49 (0) anfrage@phenomenex.com India t: +9 (0) f: +9 (0) indiainfo@phenomenex.com Ireland t: +353 (0) f: eireinfo@phenomenex.com Luxembourg t: +3 (0) f: +3 (0) nlinfo@phenomenex.com Mexico t: f: tecnicomx@phenomenex.com The Netherlands t: +3 (0) f: +3 (0) nlinfo@phenomenex.com New Zealand t: +64 (0) f: +64 (0) nzinfo@phenomenex.com Norway t: f: nordicinfo@phenomenex.com Puerto Rico t: + (800) 54-HPLC f: + (30) info@phenomenex.com Spain t: f: espinfo@phenomenex.com Sweden t: +46 (0) f: nordicinfo@phenomenex.com United Kingdom t: +44 (0) f: +44 (0) ukinfo@phenomenex.com USA t: + (30) f: + (30) info@phenomenex.com All other countries Corporate Office USA t: + (30) f: + (30) info@phenomenex.com Italy t: f: italiainfo@phenomenex.com BR935046_I Phenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department at international@phenomenex.com Terms and Conditions Subject to Phenomenex Standard Terms and Conditions, which may be viewed at Trademarks Zebron, Arylene Matrix Technology, Cool-Lock, Enviro-Inert, ESC (Engineered Self Cross-linking ), Glass Infusion, Guardian, Inferno, MultiResidue, 5MSplus and WAXplus are trademarks of Phenomenex. Rtx, MXT, Rxi, Stx, XTI and StabilWax are registered trademarks of Restek Corp. Agilent and J&W are registered trademarks of Agilent Technologies, Inc. Varian is a registered trademark under license to Agilent Technologies, Inc. POLYWAX is a registered trademark of Baker Hughes Inc. Disclaimer Comparative separations may not be representative of all applications. Phenomenex is not affiliated with Restek Corp., Agilent Technologies, Varian, or Baker Hughes Inc. Cool-Lock Nut is patented by Phenomenex. U.S. Patent No. 8, 06, 56 The opinions stated herein are solely those of the speaker and not necessarily those of any company or organization. 06 Phenomenex, Inc. All rights reserved.

New ZB-5HT Inferno The World s Highest Temperature Non-Metal GC Column

New ZB-5HT Inferno The World s Highest Temperature Non-Metal GC Column New ZB-5HT Inferno The World s Highest Temperature Non-Metal GC Column The World's First Non-metal 5% Phenyl Phase GC Column Rated to 430 C * Specially processed for thermal stability up to 430 C A true

More information

Fast, Accurate Environmental Testing

Fast, Accurate Environmental Testing GC Columns Fast, Accurate Environmental Testing Using Zebron GC Columns Featuring Pesticides Diesel Range Organics Semivolatiles Dioxane And more.. www.phenomenex.com/environmental Semi-Volatile Organic

More information

Appendices References...49 Glossary Equations

Appendices References...49 Glossary Equations Table of Contents List of Tables...2 List of Figures...2 Column Selection General Considerations for Column Selection... 3-11 Your Zebron Capillary GC Column... 12-29 Column Installation Pre-Installation

More information

The BIG GC Special. Details, Playoff Specials, and Early Bird Discounts Inside! Expires: December 20, 2013 Mention Offer Code: ZBNF1213.

The BIG GC Special. Details, Playoff Specials, and Early Bird Discounts Inside! Expires: December 20, 2013 Mention Offer Code: ZBNF1213. The BIG GC Special Details, Playoff Specials, and Early Bird Discounts Inside! Exclusive Savings on Zebron GC Columns for any phase new to your company* Length 10-15 Meter 30 Meter 60 Meter Sale Price

More information

Analysis. Priority LC GC. Zebron PAH Accurately quantitate EU and EPA PAHs in less than 28 minutes

Analysis. Priority LC GC. Zebron PAH Accurately quantitate EU and EPA PAHs in less than 28 minutes Priority Analysis LC GC Core-Shell Technology GC Columns Kinetex PAH Expanded resolution with chemical selectivity specifically for PAHs Increased throughput and sensitivity with core-shell technology

More information

Accurate, Reproducible Results for Environmental Methods with Zebron GC Columns

Accurate, Reproducible Results for Environmental Methods with Zebron GC Columns Accurate, Reproducible Results for Environmental Methods with Zebron GC Columns BUY NOW AND SAVE! Length Sale Price* 10-15 meter $ 199 30 meter $ 399 60 meter $ 599 *Offer valid only for addressee, limit

More information

The Suite for Environmental GC Analysis

The Suite for Environmental GC Analysis The Suite for Environmental GC Analysis SGE Environmental GC Columns Performance Selectivity Delivery Promise www.sge.com SGE Environmental GC Columns The Suite for Environmental GC Analysis SGE GC Columns

More information

4. Place a 20 ml VOA vial in position 1 of the tray. 5. Place a 6 ml C18-E cartridge in position 1 of the carousel.

4. Place a 20 ml VOA vial in position 1 of the tray. 5. Place a 6 ml C18-E cartridge in position 1 of the carousel. Increase Throughput and Recoveries for EPA Method 508.1 with Automated Extraction using Strata C18-E SPE Cartridges and Zebron ZB-MultiResidue GC Columns Kali Tudela Phenomenex, Inc., 411 Madrid Ave.,

More information

Take Your Food Testing to the Next Level

Take Your Food Testing to the Next Level GC Columns Take Your Food Testing to the Next Level Using Zebron GC Columns Featuring Pesticides FAMEs Essential Oils Flavors And more.. www.phenomenex.com/foodgc Pesticide Screening by GC-MS - 7 7 9,9

More information

So Many Columns! How Do I Choose? Daron Decker Chromatography Technical Specialist

So Many Columns! How Do I Choose? Daron Decker Chromatography Technical Specialist So Many Columns! How Do I Choose? Daron Decker Chromatography Technical Specialist GC Columns Wall Coated Open Tubulars Liquid phase coated capillaries Internal Diameter 0.05 0.53mm Length 5m 100m Porous

More information

Choosing the Correct GC Column Dimensions and Stationary Phase

Choosing the Correct GC Column Dimensions and Stationary Phase Choosing the Correct GC Column Dimensions and Stationary Phase Daron Decker Chromatography Technical Specialist Page 1 Nothing is useless it can always serve as a bad example Custom Column: 150 m x 250

More information

Trajan SGE GC Columns

Trajan SGE GC Columns Trajan Scientific and Medical Trajan SGE GC Columns Trajan Scientific and Medical Our focus is on developing and commercializing technologies that enable analytical systems to be more selective, sensitive

More information

40 % OFF. Upgrade to Zebron GC Columns. Equivalent Selectivity. Better Service. ZB-1ms ZB-5 ZB-624. ZB-5ms ZB-WAX ZB-1.

40 % OFF. Upgrade to Zebron GC Columns. Equivalent Selectivity. Better Service. ZB-1ms ZB-5 ZB-624. ZB-5ms ZB-WAX ZB-1. Upgrade to Zebron GC Columns Equivalent Selectivity. Better Service. ZB-ms ZB-5 ZB-64 ZB- 40 % OFF Zebron GC columns ZB-WAX ZB-5ms * Expires: October 30, 009 Please Mention Offer Code: ZBE009 * Offer applies

More information

Rtx -CLPesticides Columns Reduce Analysis Time; Reduce System Maintenance

Rtx -CLPesticides Columns Reduce Analysis Time; Reduce System Maintenance Columns Reduce Analysis Time; Reduce System Maintenance 0 YEARS Turning Visions into Reality www.restek.com 00-- --00 and Fused Silica Columns Detect and confirm 0 common organochlorine pesticides simultaneously.

More information

Multi-residue Analysis for PAHs, PCBs and OCPs on Agilent J&W FactorFour VF-Xms

Multi-residue Analysis for PAHs, PCBs and OCPs on Agilent J&W FactorFour VF-Xms Multi-residue Analysis for PAHs, PCBs and OCPs on Agilent J&W FactorFour VF-Xms Application Note Author Laura Provoost Agilent Technologies, Inc. Introduction In multi-residue analysis different groups

More information

How To Select the Correct GC Column. Simon Jones Application Engineer

How To Select the Correct GC Column. Simon Jones Application Engineer How To Select the Correct GC Column Simon Jones Application Engineer Things to Consider Is it Volatile enough to chromatograph by GC? Is it a Gas or a Liquid? How are we getting the Sample Injected? What

More information

3 Ways To Choose. All GC 5 Phases Are Not The Same! ZB-5. ZB-5MSi. ZB-5HT Inferno. ZB-5ms ZB-5MSPLUS. ZB-SemiVolatiles.

3 Ways To Choose. All GC 5 Phases Are Not The Same! ZB-5. ZB-5MSi. ZB-5HT Inferno. ZB-5ms ZB-5MSPLUS. ZB-SemiVolatiles. 3 Ways To Choose All GC 5 Phases Are Not The Same! ZB-5 ZB-5M ZB-5HT Inferno ZB-5ms ZB-5MSPLUS ZB-SemiVolatiles www.phenomenex.com/5phase Choosing Your 5 Phase Is Easy Use the NEW GC Column Finder web

More information

A New PEG GC Column with Improved Inertness Reliability and Column Lifetime Agilent J&W DB-WAX Ultra Inert Polyethylene Glycol Column

A New PEG GC Column with Improved Inertness Reliability and Column Lifetime Agilent J&W DB-WAX Ultra Inert Polyethylene Glycol Column A New PEG GC Column with Improved Inertness Reliability and Column Lifetime Agilent J&W DB-WAX Ultra Inert Polyethylene Glycol Column Competitive Comparison Authors Ngoc-A Dang and Allen K. Vickers Agilent

More information

Understanding the Capillary GC Column: How to Choose the Correct Type and Dimension

Understanding the Capillary GC Column: How to Choose the Correct Type and Dimension Understanding the Capillary GC Column: How to Choose the Correct Type and Dimension Simon Jones Application Engineer Things to Consider Is it Volatile enough to chromatograph by GC? Is it a Gas or a Liquid?

More information

Slightly Polar Columns

Slightly Polar Columns 9000 Варна, ул.поп Харитон 47 e-mail : gea99@abv.bg www.geya99.com Slightly Polar Columns With the partnership of Teknokroma SLIGHTLY POLAR COLUMNS TRB-5 It is the most universal and versatile stationary

More information

Gemini-NX Performance paired with Axia Technology

Gemini-NX Performance paired with Axia Technology Si Si Si Si Si Si Si C Si Si Si Si Si Gemini-NX Performance paired with Axia Technology Gemini -NX Axia Packed Technology Improves Yield, Throughput, and Column Lifetime Ideal Purification Platform While

More information

environmental Rtx -CLPesticides and Rtx -CLPesticides2 Columns: The Ideal Confirmational Pair for Analyzing Polychlorinated Biphenyls (PCBs)

environmental Rtx -CLPesticides and Rtx -CLPesticides2 Columns: The Ideal Confirmational Pair for Analyzing Polychlorinated Biphenyls (PCBs) environmental #59120 Applications note Rtx -CLPesticides and Rtx -CLPesticides2 Columns: The Ideal Confirmational Pair for Analyzing Polychlorinated Biphenyls (PCBs) Polychlorinated biphenyls (PCBs) are

More information

Low Bleed Stationary Phases for Gas Chromatography

Low Bleed Stationary Phases for Gas Chromatography Low Bleed Stationary Phases for Gas Chromatography Slide 4 Advantages of Low Bleed Phase Lower bleed compared to standard phases Better signal to noise (sensitivity) Higher upper temperature - shorter

More information

Selection of a Capillary

Selection of a Capillary Selection of a Capillary GC Column - Series 3 Mark Sinnott Application Engineer March 19, 2009 Page 1 Typical Gas Chromatographic System Mol-Sieve Traps Fixed Restrictors Regulators Injection Port Detector

More information

BP1 PONA BPX1. GC Capillary Columns BP1 PONA and BPX1

BP1 PONA BPX1. GC Capillary Columns BP1 PONA and BPX1 GC Capillary Columns 100% Dimethyl Polysiloxane GC Columns and Applications ID (mm) Film Thickness (µm) Length (m) Temperature Limits ( C) Part No. 0.32 0.5 60-60 to 320/340 054069 0.32 1 60-60 to 320/340

More information

AGGREGATE ANALYSIS. Biologics Workflow. by Size Exclusion Chromatography

AGGREGATE ANALYSIS. Biologics Workflow. by Size Exclusion Chromatography Biologics Workflow AGGREGATE ANALYSIS by Size Exclusion Chromatography New biozen SEC columns provide: High efficiency on both HPLC and UHPLC Extreme inertness and robustness Finely tuned high and low

More information

Evaluating CLP and EPA Methods for Pesticides in Water Using Agilent J&W DB-CLP1/DB-CLP2 GC Columns

Evaluating CLP and EPA Methods for Pesticides in Water Using Agilent J&W DB-CLP1/DB-CLP2 GC Columns Evaluating CLP and EPA Methods for Pesticides in Water Using Agilent J&W DB-CLP/DB-CLP GC Columns Application Note Environmental Authors Doris Smith and Ken Lynam Agilent Technologies, Inc. Abstract The

More information

Selection of a Capillary GC Column

Selection of a Capillary GC Column Selection of a Capillary GC Column Mark Sinnott Application Engineer March 13, 2008 Page 1 Typical Gas Chromatographic System Mol-Sieve Traps Fixed Restrictors Regulators Injection Port Detector Electrometer

More information

Introduction to Gas Chromatography

Introduction to Gas Chromatography Introduction to Gas Chromatography 31-1 Objectives To know what is chromatography To understand the mechanism of compound separation To know the basic of gas chromatography system 31-2 Chromatography Definition

More information

Introduction and Principles of Gas Chromatography

Introduction and Principles of Gas Chromatography Introduction and Principles of Gas Chromatography Jaap de Zeeuw Restek, Middelburg, The Netherlands Jaap.dezeeuw@restek.com Definition and Uses of Gas Chromatography GC Components and Types of Columns

More information

Your Reversed Phase Method

Your Reversed Phase Method PLC Columns for Your Reversed Phase Method Balanced Non-Polar & Polar Selectivity Strong Non-Polar & Polar Selectivity Strong Polar & Aromatic Selectivity Unique Isomeric & alogenated Selectivity Robust

More information

Agilent J&W GC Column Selection Guide SPEED YOUR SELECTION WITH THIS ONE-STOP RESOURCE

Agilent J&W GC Column Selection Guide SPEED YOUR SELECTION WITH THIS ONE-STOP RESOURCE Agilent J&W GC Column Selection Guide SPEED YOUR SELECTION WITH THIS ONE-STOP RESOURCE Table of Contents The story behind Agilent J&W Advanced GC Columns... 1 Column Selection Principles... 3 Selecting

More information

APPLICATIONS TN Peptide Purification Method Development: Application for the Purification of Bivalirudin. Introduction

APPLICATIONS TN Peptide Purification Method Development: Application for the Purification of Bivalirudin. Introduction Peptide Purification Method Development: Application for the Purification of Bivalirudin Marc Jacob, Joshua Heng, and Tivadar Farkas Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 91 USA In this technical

More information

Agilent J&W GC Column Selection Guide

Agilent J&W GC Column Selection Guide Agilent J&W GC Column Selection Guide Rely on unsurpassed reproducibility, efficiency, and inertness. Speed your selection with this one-stop resource. Agilent J&W GC Column Selection Guide Table of Contents

More information

Quick and Simple Cleanup for. Medicinal Chemistry. It s BIG.

Quick and Simple Cleanup for. Medicinal Chemistry. It s BIG. Quick and Simple Cleanup for Medicinal It s IG. Guaranteed Cleanup of Post Synthesis Reactions Strata -XL Giga s are designed to make Medicinal easy! With Strata Giga tubes I ve been able to purify a compound

More information

SUPELCO. Improved Performance for Cyanopropylphenyldimethylpolysiloxane (SPB-1701, SPB-1301) Capillary Columns

SUPELCO. Improved Performance for Cyanopropylphenyldimethylpolysiloxane (SPB-1701, SPB-1301) Capillary Columns Improved Performance for Cyanopropylphenyldimethylpolysiloxane (SPB-1701, SPB-1301) Capillary Columns L.M. Sidisky, Yizeng Ni, Greg Baney, Rodney George, Katherine K. Stenerson 01-0026 T401044 CFK Discussion

More information

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols. An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols. Jaap de Zeeuw, Ron Stricek and Gary Stidsen Restek Corp Bellefonte, USA To analyze basic compounds at

More information

Developing Large Volume Injection (LVI) in Split / Splitless Inlets. Philip J. Koerner Phenomenex Inc. NEMC 2014

Developing Large Volume Injection (LVI) in Split / Splitless Inlets. Philip J. Koerner Phenomenex Inc. NEMC 2014 Developing Large Volume Injection (LVI) in Split / Splitless Inlets Philip J. Koerner Phenomenex Inc. NEMC 2014 Goal To produce a method that provides the largest response of analytes that will produce

More information

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software High Efficiency GC Columns Page 1 Variables for Shortening Run Times Stationary Phase Shorten Column Length

More information

A New Web-Based Application for Modeling Gas Chromatographic Separations

A New Web-Based Application for Modeling Gas Chromatographic Separations A New Web-Based Application for Modeling Gas Chromatographic Separations Jaap de Zeeuw**, Rebecca Stevens*, Amanda Rigdon, Linx Waclaski*and Dan Li* *Restek Corporation, Bellefonte, PA, USA **Restek Corporation,

More information

Ultra-Inert chemistry for Trace Level Analysis

Ultra-Inert chemistry for Trace Level Analysis Ultra-Inert chemistry for Trace Level Analysis Cikui Liang, Ph.D. Challenges and Needs of Today s Laboratories Challenges Qualification/quantification of trace samples Keep instrument up and running Needs

More information

Column Selection. there is more to life than a boiling point column. Jaap de Zeeuw Restek Corporation, The Netherlands. Copyrights: Restek Corporation

Column Selection. there is more to life than a boiling point column. Jaap de Zeeuw Restek Corporation, The Netherlands. Copyrights: Restek Corporation Column Selection there is more to life than a boiling point column Jaap de Zeeuw Restek Corporation, The Netherlands Stationary Phase Selectivity Boiling Point versus Solubility Retention of a compound

More information

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software GC Columns and Consumables Mark Sinnott Application Engineer January 8 th, 2008 Page 1 Questions to Ask

More information

Capillary GC Column Selection and Method Development A Primer on Column Parameters and Instrument Conditions

Capillary GC Column Selection and Method Development A Primer on Column Parameters and Instrument Conditions Capillary GC Column Selection and Method Development A Primer on Column Parameters and Instrument Conditions Michael D. Buchanan September 11, 2014 sigma-aldrich.com/analytical 2012 Sigma-Aldrich Co. All

More information

Optimizing GC Parameters for Faster Separations with Conventional Instrumentation

Optimizing GC Parameters for Faster Separations with Conventional Instrumentation Optimizing GC Parameters for Faster Separations with Conventional Instrumentation Anila I. Khan, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 243 Key Words TraceGOLD fast GC analysis

More information

Activity in the FID Detection Port: A Big Problem if Underestimated

Activity in the FID Detection Port: A Big Problem if Underestimated Activity in the FID Detection Port: A Big Problem if Underestimated Jaap de Zeeuw, Restek Corporation, Middelburg, The Netherlands It is commonly known in gas chromatography, that many problems can be

More information

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System Application Note Residual Solvent Analysis of USP Method Residual Solvents on the Agilent 889 GC System Author Lukas Wieder, Jie Pan, and Rebecca Veeneman Agilent Technologies, Inc. 8 Centerville Road

More information

Get Selective. By Jaap de Zeeuw

Get Selective. By Jaap de Zeeuw 34 Get Selective Modern narrow bore columns have made chromatographers lazy when it comes to stationary phase selection. Here s how getting back to basics in gas chromatography by using selectivity can

More information

GC Resolution Do You See What I See?

GC Resolution Do You See What I See? GC Resolution Do You See What I See? Column Dimensions and Carrier Gas Optimization Deans Switch Page 1 Variables for Maximizing Resolution Optimized Stationary Phase Longer Column Length Decrease Internal

More information

A New Web-Based Application for Modeling Gas Chromatographic Separations. Dr. Hansjoerg Majer Restek Corporation Market Development Manager Europe

A New Web-Based Application for Modeling Gas Chromatographic Separations. Dr. Hansjoerg Majer Restek Corporation Market Development Manager Europe A New Web-Based Application for Modeling Gas Chromatographic Separations Dr. Hansjoerg Majer Restek Corporation Market Development Manager Europe The Method Development Process in GC $ SUCCESS! Developing

More information

Secrets of GC Column Dimensions

Secrets of GC Column Dimensions Secrets of GC Column Dimensions GC Columns and Consumables Simon Jones Application Engineer May 20, 2008 Slide 1 Secrets of GC Column Dimensions Do I have the right column phase? Resolution Equation Changes

More information

USP <467> Headspace Residual Solvent Assay with a HT3 Headspace Instrument

USP <467> Headspace Residual Solvent Assay with a HT3 Headspace Instrument Application Note Abstract The US Pharmacopeia recently released USP as the current monograph for determining residual solvents in pharmaceutical products by static headspace. The USP classified these

More information

Product Brief. - Hydrocarbons alkanes, alkenes, alkynes, dienes including natural gas, refinery gas, liquified petroleum gas

Product Brief. - Hydrocarbons alkanes, alkenes, alkynes, dienes including natural gas, refinery gas, liquified petroleum gas Agilent Porous Polymer PLOT Columns: New Products, Expanded Uses, Prices Cut in Half! Product Brief Need improved resolution of small volatile compounds? Didn't try a PLOT column due to high price, short

More information

Evaluation of Capillary Columns for General Performance Parameters

Evaluation of Capillary Columns for General Performance Parameters Evaluation of Capillary s for General Performance Parameters Application Authors Mitch Hastings, Eberhardt R. Kuhn and Allen K. Vickers Agilent Technologies, Inc 91 Blue Ravine Road Folsom, CA 95630 USA

More information

Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor

Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor Application Note Pesticides Authors Charlie Spanjers and Paul Dauenhauer University of Minnesota, Twin Cities

More information

Determination of Organochlorine Pesticides and Polychlorinated Biphenyls Using GC/MS/MS Operated in the MRM Mode

Determination of Organochlorine Pesticides and Polychlorinated Biphenyls Using GC/MS/MS Operated in the MRM Mode PO-CON1610E Determination of Organochlorine Pesticides and Polychlorinated Biphenyls Using GC/MS/MS Operated in the MRM Mode Pittcon 2016 1110-2 Brahm Prakash, William Lipps, Di Wang, Shilpi Chopra, Nicole

More information

Guide to GC Column Selection and Optimizing Separations

Guide to GC Column Selection and Optimizing Separations Guide to GC Column Selection and Optimizing Separations WHICH COLUMN DO I NEED? Learn how to choose the right column the first time. Optimize separations for the best balance of resolution and speed. Troubleshoot

More information

Water Injections in GC - Does Water Cause Bleed?

Water Injections in GC - Does Water Cause Bleed? Water Injections in GC - Does Water Cause Bleed? Eberhardt Kuhn Applications Chemist April 4, 2001 Practical Advice and Useful Tips for the Analysis of Semivolatile Organics by GC and GC/MS 11:00 a.m.

More information

Understanding Gas Chromatography

Understanding Gas Chromatography Understanding Gas Chromatography What is Really Going on Inside the Box? Simon Jones GC Applications Engineer Page 1 Group/Presentation Title Month ##, 200X ?? K? Page 2 Typical GC System Gas supply Injector

More information

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application Analysis of Trace (mg/kg) Thiophene in Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application Petrochemical Authors James D. McCurry and Bruce D. Quimby Agilent Technologies

More information

Agilent UltiMetal Plus Stainless Steel Deactivation for Tubing, Connectors, and Fittings

Agilent UltiMetal Plus Stainless Steel Deactivation for Tubing, Connectors, and Fittings Agilent UltiMetal Plus Stainless Steel Deactivation for Tubing, Connectors, and Fittings Technical Overview Introduction Modern GC and GC/MS instruments are important analytical tools for accurate and

More information

Column Dimensions. GC Columns and Consumables. Mark Sinnott Application Engineer. March 12, 2010

Column Dimensions. GC Columns and Consumables. Mark Sinnott Application Engineer. March 12, 2010 Secrets of GC Column Dimensions GC Columns and Consumables Mark Sinnott Application Engineer Folsom California March 12, 2010 Page 1 Secrets of GC Column Dimensions Do I have the right column phase? Resolution

More information

Study of Residual Solvents in Various Matrices by Static Headspace

Study of Residual Solvents in Various Matrices by Static Headspace Application Note Abstract United States Pharmacopeia (USP) chapter is a widely used method for identifying and quantifying Organic Volatile Impurities (OVI) used in the production of pharmaceuticals.

More information

APPLICATIONS TN Separation and Quantitation of Physiologic Cobalamins (Vitamin B 12

APPLICATIONS TN Separation and Quantitation of Physiologic Cobalamins (Vitamin B 12 APPLICATIONS Separation and Quantitation of Physiologic Cobalamins (Vitamin B 12 in Dietary Supplements by LC/MS/MS using Synergi Fusion-RP Column Xianrong (Jenny Wei Senior Scientist PhenoLogix applications

More information

Introducing New Functionalities in Liquid Stationary Phases in GC Columns for Confirming Organic Volatile Impurity Testing in Pharmaceutical Products.

Introducing New Functionalities in Liquid Stationary Phases in GC Columns for Confirming Organic Volatile Impurity Testing in Pharmaceutical Products. Introducing New Functionalities in Liquid Stationary Phases in GC Columns for Confirming Organic Volatile Impurity Testing in Pharmaceutical Products. CHRISTOPHER M. ENGLISH, CHRISTOPHER S. COX, FRANK

More information

Fast and Accurate Analysis of PBDEs in a Single Run, Including

Fast and Accurate Analysis of PBDEs in a Single Run, Including Fast and Accurate Analysis of PBDEs in a Single Run, Including Kory Kelly, Adam Endeman, and Matthew Trass Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 90501 USA PO14700713_2 PO14400613_W_2 Abstract

More information

Speakers. Moderator. John V Hinshaw GC Dept. Dean CHROMacademy. Tony Taylor Technical Director CHROMacademy. Dave Walsh Editor In Chief LCGC Magazine

Speakers. Moderator. John V Hinshaw GC Dept. Dean CHROMacademy. Tony Taylor Technical Director CHROMacademy. Dave Walsh Editor In Chief LCGC Magazine Webcast Notes Type your questions in the Submit Question box, located below the slide window You can enlarge the slide window at any time by clicking on the Enlarge Slides button, located below the presentation

More information

Organochlorine Pesticides by GCxGC-ECD

Organochlorine Pesticides by GCxGC-ECD Organochlorine Pesticides by GCxGC-ECD LECO Corporation; Saint Joseph, Michigan USA Key Words: GCxGC-ECD, Environmental, Quantification 1. Introduction United States Environmental Protection Agency Method

More information

Rtx-BAC Plus 1 and Rtx-BAC Plus 2 Columns Advanced Technology for Fast, Reliable Measurement of Alcohol in Blood

Rtx-BAC Plus 1 and Rtx-BAC Plus 2 Columns Advanced Technology for Fast, Reliable Measurement of Alcohol in Blood Restek GC LC Rtx-BAC Plus and Rtx-BAC Plus Columns Advanced Technology for Fast, Reliable Measurement of Alcohol in Blood Optimized column selectivities guarantee resolution of ethanol, internal standards,

More information

GAS CHROMATOGRAPHY (GC)

GAS CHROMATOGRAPHY (GC) GAS CHROMATOGRAPHY (GC) Pre-Lab Questions Questions are to be answered before the beginning of the laboratory. The answers are due at the beginning of each experiment (the questions are for credit and

More information

The Design of High Temperature Capillary Gas Chromatography Columns Based on Polydimethylsiloxane

The Design of High Temperature Capillary Gas Chromatography Columns Based on Polydimethylsiloxane The Design of High Temperature Capillary Gas Chromatography Columns Based on Polydimethylsiloxane Jarl Snider, D. J. Hotnisky, Kristi Sellers, Dinesh V. Patwardhan Ph. D. Restek Corporation www.restekcorp.com

More information

Fast and Accurate Analysis of PBDEs in a Single Run, Including BDE-209

Fast and Accurate Analysis of PBDEs in a Single Run, Including BDE-209 Fast and Accurate Analysis of PBDEs in a Single Run, Including Kory Kelly, Xianrong (Jenny) Wei, and Matthew Trass Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 90501 USA PO16570913_W_2 PO14400613_W_2

More information

APPLICATIONS TN Increased Capabilities for the Analysis of Hormones in Drinking and Waste Water Using Solid Phase Extraction (SPE) and LC/MS/MS

APPLICATIONS TN Increased Capabilities for the Analysis of Hormones in Drinking and Waste Water Using Solid Phase Extraction (SPE) and LC/MS/MS Increased Capabilities for the Analysis of Hormones in Drinking and Waste Water Using Solid Phase Extraction (SPE) and LC/MS/MS Xianrong (Jenny) Wei Senior Scientist Jenny is a Senior Scientist in Phenomenex

More information

UltiMetal Plus Advanced Chemistry for Stainless Steel Surface Deactivation

UltiMetal Plus Advanced Chemistry for Stainless Steel Surface Deactivation UltiMetal Plus Advanced Chemistry for Stainless Steel Surface Deactivation Technical Overview Introduction Inert flow path technology Modern GC and GC/MS instrumentation is an important analytical tool

More information

APPLICATIONS TN HPLC Conditions. Lux Cellulose-1 Cellulose tris(3,5-dimethylphenylcarbamate)

APPLICATIONS TN HPLC Conditions. Lux Cellulose-1 Cellulose tris(3,5-dimethylphenylcarbamate) T-147 APPLICATIS Alternative Selectivity of Chiral Stationary Phases Based on Cellulose tris(3-chloro-4-methylphenylcarbamate) and Cellulose tris(3,5-dimethylphenylcarbamate) Liming Peng, Tivadar Farkas

More information

Analyze Hydrocarbon Impurities in 1,3-Butadiene with an Agilent J&W GS-Alumina PT Column

Analyze Hydrocarbon Impurities in 1,3-Butadiene with an Agilent J&W GS-Alumina PT Column Analyze Hydrocarbon Impurities in,3-butadiene with an Agilent J&W GS-Alua PT Column Application Note Energy and Chemicals Authors Yun Zou and Chunxiao Wang Agilent Technologies Shanghai Ltd Abstract The

More information

Highly Sensitive and Rugged GC/MS/MS Tool

Highly Sensitive and Rugged GC/MS/MS Tool Highly Sensitive and Rugged GC/MS/MS Tool For Pesticide Multiresidue Analysis in Food Samples Agilent 7 Series Triple Quadrupole GC/MS. The world s first MS/MS designed specifically for GC Analysis Introduction

More information

NEW Rtx -BAC Plus 1 and Rtx -BAC Plus 2 Columns

NEW Rtx -BAC Plus 1 and Rtx -BAC Plus 2 Columns NEW Rtx -BAC Plus and Rtx -BAC Plus Columns Advanced Technology for Fast, Reliable Measurement of Alcohol in Blood Optimized column selectivities guarantee resolution of ethanol, internal standards, and

More information

Fast Analysis of Aromatic Solvent with 0.18 mm ID GC column. Application. Authors. Introduction. Abstract. Gas Chromatography

Fast Analysis of Aromatic Solvent with 0.18 mm ID GC column. Application. Authors. Introduction. Abstract. Gas Chromatography Fast Analysis of Aromatic Solvent with.8 mm ID GC column Application Gas Chromatography Authors Yun Zou Agilent Technologies (Shanghai) Co. Ltd. Ying Lun Road Waigaoqiao Free Trade Zone Shanghai 3 P.R.

More information

New Application Specific Columns for Semi-volatile and ECD Methods Lead the Way to Higher Productivity in Environmental Laboratories

New Application Specific Columns for Semi-volatile and ECD Methods Lead the Way to Higher Productivity in Environmental Laboratories New Application Specific Columns for Semi-volatile and ECD Methods Lead the Way to Higher Productivity in Environmental Laboratories Ken Lynam CSD Application Chemist Presentation Outline DB-UI 8270D columns

More information

Author. Abstract. Introduction

Author. Abstract. Introduction Improved Performance for the Analysis of Aromatics in Gasoline by ASTM Method D5769 Using the Agilent 5973 inert Gas Chromatography/Mass Spectrometry System Application Author James D. McCurry Agilent

More information

VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography

VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography Introduction ASTM International publishes a number of different methods for the determination of volatile compounds in water-based coatings.

More information

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011 ?? Kβ? Page 1 Typical GC System Gas supply Injector Detector Data handling GAS Column Oven Page 2 CARRIER GAS Carries the solutes down the column Selection and velocity influences efficiency and retention

More information

PYRETHROID ANALYSIS. MARKET FOCUSED - Environmental TECHNICAL ARTICLE

PYRETHROID ANALYSIS. MARKET FOCUSED - Environmental TECHNICAL ARTICLE www.sge.com MARKET CUSED - Environmental PYRETHRID AALYSIS Pyrethroids are potent insecticides widely used in agriculture, disease control and household products. early all domestic fly aerosols use pyrethroids

More information

Virtually Particle-Free Rt -Silica BOND Columns

Virtually Particle-Free Rt -Silica BOND Columns Petrochemical Applications Virtually Particle-Free Rt -Silica BOND s Provide Reliable PLOT Performance With Less Time Lost for Maintenance By Amanda Rigdon, Bill Bromps, Tom Vezza, and Jaap de Zeeuw Optimized

More information

GC Section. Astec, Agilent/J&W, SGE, Quadrex

GC Section. Astec, Agilent/J&W, SGE, Quadrex GC Section GC Columns..............................328-384 Introduction..............................329-330 Capillary Columns, Alltech................331-352 Custom Columns.......................... 331

More information

APPLICATIONS TN Lux Cellulose-2 or -4 Cellulose tris (3-chloro-4-methylphenylcarbamate) or (4-chloro-3-methylphenylcarbamate)

APPLICATIONS TN Lux Cellulose-2 or -4 Cellulose tris (3-chloro-4-methylphenylcarbamate) or (4-chloro-3-methylphenylcarbamate) T-1079 APPLICATI Method Development for Reversed Phase Chiral LC/M/M Analysis of tereoisomeric Pharmaceutical Compounds with Polysaccharide-based tationary Phases Philip J. Koerner, Kari Carlson, Liming

More information

The Standard for ph Method Development

The Standard for ph Method Development The Standard for ph Method Development High Efficiency Excellent Lifetime ph Stable - www.phenomenex.com/gemini U.S. Patent No.,, Setting the Standard for ph Method Development Gemini columns are rugged

More information

CH 2252 Instrumental Methods of Analysis Unit V Gas Chromatography. M. Subramanian

CH 2252 Instrumental Methods of Analysis Unit V  Gas Chromatography.  M. Subramanian CH 2252 Instrumental Methods of Analysis Unit V Gas Chromatography M. Subramanian Assistant Professor Department of Chemical Engineering Sri Sivasubramaniya Nadar College of Engineering Kalavakkam 603

More information

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling Andrea Caruso and Massimo Santoro, Thermo Fisher Scientific, Milan, Italy Application Note 1316 Key

More information

NEW Agilent J&W Ultra Inert Capillary GC Columns. Proven performance that raises the bar on. consistent. column inertness.

NEW Agilent J&W Ultra Inert Capillary GC Columns. Proven performance that raises the bar on. consistent. column inertness. NEW Agilent J&W Ultra Inert Capillary GC Columns Proven performance that raises the bar on consistent column inertness. Finally a column technology that gives you better sensitivity and peak shape for

More information

Introduction to Capillary GC

Introduction to Capillary GC ?? Kβ? Page 1 Typical GC System Gas supply Injector Detector Data handling GAS Column Oven Page 2 CARRIER GAS Carries the solutes down the column Selection and velocity influences efficiency and retention

More information

Supelco Ionic Liquid GC Columns Introduction to the Technology

Supelco Ionic Liquid GC Columns Introduction to the Technology Supelco Ionic Liquid GC Columns Introduction to the Technology Updated: -Jan-203 Agenda Overview GC Column Polarity Scale Temperature Effects on Selectivity Column Selectivity: QC Test Mix (0.2 mm I.D.

More information

Headspace Technology for GC and GC/MS: Features, benefits & applications

Headspace Technology for GC and GC/MS: Features, benefits & applications Headspace Technology for GC and GC/MS: Features, benefits & applications Karima Baudin Oct 2015 Why use Headspace? Very Simple no to minimum sample prep Robust enhance uptime Non-detectable carry-over

More information

Grace GC Capillary Column Families

Grace GC Capillary Column Families Grace GC Capillary Column Families Alltech Heliflex High-Performance, Widest Selection of Phases Alltech Econo-Cap Best Value, Popular Phases Grace offers two lines of capillary columns to suit every application

More information

Residual solvents analysis using an Agilent Intuvo 9000 GC system

Residual solvents analysis using an Agilent Intuvo 9000 GC system Residual solvents analysis using an Intuvo GC system Technology advantage: simplified dual column analysis with Flow Chip modularity Introduction USP defines a method for analysis of residual solvents

More information

USP<467> residual solvents

USP<467> residual solvents Application Note Pharmaceuticals USP residual solvents Applying the Agilent 977A MSD with the Agilent 797A headspace sampler and Agilent 7890B GC Authors Roger L. Firor and Mike Szelewski Agilent Technologies,

More information

Fast USEPA 8270 Semivolatiles Analysis Using the 6890/5973 inert GC/MSD with Performance Electronics Application

Fast USEPA 8270 Semivolatiles Analysis Using the 6890/5973 inert GC/MSD with Performance Electronics Application Fast USEPA 8270 Semivolatiles Analysis Using the 6890/5973 inert GC/MSD with Performance Electronics Application Environmental Analysis Author Mike Szelewski Agilent Technologies, Inc. 2850 Centerville

More information

Improved Peak Shape Performance and Consistency for Analysis of Challenging Polar Compounds

Improved Peak Shape Performance and Consistency for Analysis of Challenging Polar Compounds Improved Peak Shape Performance and Consistency for Analysis of Challenging Polar Compounds Laura Provoost GC Columns Product Manager Agilent CrossLab Group Challenges when analyzing active polar compounds

More information