Grace GC Capillary Column Families

Size: px
Start display at page:

Download "Grace GC Capillary Column Families"

Transcription

1 Grace GC Capillary Column Families Alltech Heliflex High-Performance, Widest Selection of Phases Alltech Econo-Cap Best Value, Popular Phases Grace offers two lines of capillary columns to suit every application and budget; Alltech Heliflex and Alltech Econo-Cap. Heliflex Columns are Grace s line of individually tested capillary columns. Econo-Cap Columns are batch tested to dramatically reduce the price without sacrificing quality. Both the Heliflex and Econo-Cap lines are manufactured under identical conditions using the same high-quality polyimide coated fused silica and immobilized stationary phases. In addition each are mounted on a rugged cage. Regardless of the capillary line you choose, every Grace manufactured capillary column has a guarantee of column performance. Alltech Heliflex Capillary Columns High-performance individually tested columns 7" rugged cage Most complete selection of phases Custom columns available to suit your specific application Heliflex Capillary Columns are manufactured from the highest quality polyimide coated synthetic fused silica. They are mounted on a rugged wear-resistant cage. Each Heliflex Column is individually tested to guarantee column performance and comes with a test chromatogram, instruction manual, capillary end caps, and a free ceramic column cutter. Note: Column nuts and ferrules are not included. If the column you need is not available in our standard offering, request a custom Heliflex Column made to your individual specifications. Alltech Econo-Cap Capillary Columns Best value in capillary columns anywhere Batch tested to dramatically reduce price value Ideal for aggressive applications Available in the most popular phases We ve taken our most popular capillary columns and perfected the manufacturing procedure to the point that reproducibility is assured. This allows us to test these columns in batches instead of individually, while still offering a guarantee. Batch testing significantly reduces cost in production without sacrificing quality. Each Econo-Cap Capillary Column comes with a copy of the batch test results, an instruction manual, and capillary end caps. If you are not completely satisfied with the quality of your Econo-Cap Capillary Column it will be replaced at no charge. Available Alltech Heliflex Phases Phase Page AT -ms 6 AT -ht 6 AT - 7 AT -5ms 8 AT -5 8 AT -0 9 AT -5ms 0 AT -5 0 AT -50 AT -6 6 AT -0 AT -70 AT -0 AT -5 6 AT -WAXms AT -WAX AT -AquaWax AT -AquaWax-DA AT AT -FAME 5 AT -CAM 5 AT -Amino Acid 8 Drug, Drug, and Drug 8 USP Method 67 Kits 9 AT -Pesticide 0 AT AT -Petro AT -887 AT -70 AT -Sulfur AT -Amine AT -Silar-90 7 AT -Silar-00 7 Available Alltech Econo-Cap Phases Phase Page EC - 7 EC -5 9 EC -0 9 EC -WAX EC tech tip Temperature limits Our GC capillary columns are temperature rated. In some cases, we list two maximum operating temperatures, the lower one is for isothermal condition and the higher one for temperatureprogrammed condition. 58 Note: Column nuts and ferrules are not included.

2 Capillary Column Phase Cross Reference Use the chart below to cross reference manufacturers stationary phases as well as USP method designations to Alltech equivalent columns. Slight variations in selectivity may result between different manufacturers columns. Alltech Standard Phase Cross Reference Standard Phase Cross Reference Composition Alltech Brand Usp Designation Similiar Phases 00% Dimethylpolysiloxane AT -ms G, G, G8 DB-ms, HP-ms, Rtx -ms, CP-Sil 5CB low-bleed/ms 00% Dimethylpolysiloxane AT -ht, AT -, EC - G, G, G8 007-, CP-Sil 5CB, DB-, DB-ht, HP-, HP-0, OV -, RSL-50, RSL-60, Rtx -, SE-0, SPB -, SPB -Sulfur, ULTRA-, SP-00, BP-, DC-00, PE-, ZB- 5% Phenyl equivalent Polysilphenylene-Siloxane AT -5ms DB-5ms, Rtx -5 Sil ms, BPX -5, 007-5ms, HP-5ms (5% Phenyl)- 95% methylpolysiloxane (0% Phenyl)- 80% methylpolysiloxane (5 Phenyl)- 65% Methylpolysiloxane (50 Phenyl)- 50% methylpolysiloxane (6% Cyanopropylphenyl)- 9% methylpolysiloxane (% Cyanopropylphenyl)- 86% methylpolysiloxane Trifluoropropylmethyl polysiloxane (50% Cyanopropylphenyl)- 50% methylpolysiloxane Poly(80% biscyanopropyl)- 0% cyanoproylphenyl siloxane Poly(biscyanopropyl siloxane) Polyethyleneglycol Polyethyleneglycol Acid Modified AT -5, EC -5 AT -0, EC -0 AT -5ms AT -5 G7, G6 G8, G G 007-, CP-Sil 8CB, DB-5, DB-5.65, DB-5ht, HP-5, HP-5ms, OV -5, PTE-5, PTE-5QTM, PAS-5, RSL-00, Rtx -5, Rtx -5ms, SAC-5, SE -5, SPB -5, ULTRA-, XTI-5, SE -5, BP-5, PE-, ZB , Rtx -0, SPB -0, VOCOL, PE-7 DB-5ms, Rtx -5, SPB -5, Sup-Herb, MDN-5, BPX , DB-5, DB-5ms, HP-5, RSL-00, Rtx -5, SPB -5, SPB -608, OV -, PE-5, Sup-HERB AT -50 G DB-7ms, H5-50+, Rtx -50, SP-50, SPB -50, SPB -7, BPX -50 DB-7ht, Rtx -65TG, BPX -50, CP-TAB-CB, 007-7, DB-7, DB-7ht, HP-7, HP-50+, Rtx -50 SP-50, SP-50, SPB -50, CP-Sil CB, PE-7, ZB-50 AT -6 G 007-0, DB-6, DB-0, HP-0, HP-6, AT -0 Rtx -0, Rtx -6, SPB -0, SPB -6, 007-6, ZB-6 AT , CP-Sil 9CB, DB-70, HP-70, OV -70, PAS-70, Rtx -70, SPB -70, BP-0, ZB-70 AT -0 G6 DB-0, RSL-00, Rtx -00, OV -0, OV -0, OV -5, QF-, SP-0 AT -5 G , CP-Sil CB, DB-5, HP-5, OV -5, RSL-500, Rtx -5, BP-5, PE-5 AT -SILAR-90 G8 DB-, CP-Sil 8, Rtx -0, SP-0 AT -SILAR-00 G5 CP-Sil 88, Rtx -0, SP-0 AT -WAXms AT -WAX AT -AquaWax EC -WAX AT -000, EC -000, AT -AquaWax-DA G, G5 G6, G0, G9 G5, G5 DB-WAX, Rtx -WAX, Supelcowax CW, Carbowax 0M, CP-Wax 5CB, DB-WAXetr, DB-WAX, Rtx -WAX, HP-0M, HP-Wax, Innowax, Omegawax, Stabilwax, Supelcowax -0, Superox II, BP-0, ZB-WAX 007-FFAP, CP-Wax 58CB, DB -FFAP, HP -FFAP, Nukol, OV -5, SP-000, Stabilwax -DA, Superox -FA, BP- Polyethyleneglycol AT -CAM Stabilwax -DB, CAM, Carbowax Amine, CP Wax 5 Base Modified PONA Analysis AT -Petro F, CP-Sil PONA CB, DB-Petro00, Petrocol DH, PONA, Ttx-PONA, HP-PONA ASTM Method 887 AT V-.0F, DB-887, Petrocol 887, Petrocol EX887, Rtx -887, Sim-Dist-CB ASTM Method 70 AT -70 Petrocol 70 Alltech Specialty Columns Cross Reference Specialty Phases Cross Reference EPA Method 608 AT -Pesticide , DB-608, HP-608, SPB -608 EPA Method 50. AT , , DB-50., DB-VRX, HP-6, HP-VOC, MST-50., MXT-6, MXT-Volatiles, OV -6, Rtx -50., Rtx -6, Rtx -Volatiles, VOCOL Sulfur Analysis AT -Sulfur SPB - Sulfur FAME Analysis AT -FAME FAMEWAX, OmegaWAX

3 Alltech Custom Capillary Columns A wide selection of stationary phases s from to 05 meters Wide selection of tubing Every column individually tested Custom Capillary Column Instructions. Stationary Choose a Phase in Table : Custom Phase.. & Internal Diameter: Choose any length ( 05 meters) and internal diameter (0.0mm ) in Table : Custom Dimensions.. Thickness: Choose a film thickness; 0.0µm tolerance.. See Coiling and Guard Information for additional options. 5. Call Customer Service and they will confirm your order and provide exact prices. Table : Custom Phases Phases Available for Custom Capillary Columns Aquawax DC-550 Igepal CO-880 Aquawax-DA Dexsil 00 OV - AT - Dexsil 00 OV - AT -5 Dexsil 0 OV -7 AT -0 Di (ethylhexyl OV -70 AT -5 phthalate OV -6 AT -000 Diisodecyl phthalate OV -0 AT -0 FFAP OV -05 AT -70 Hi-EFF -AP OV -0 AT -WAX Hi-EFF -BP OV -5 AT -Amine Hi-EFF -AP Polyvinylpyrrolidone Apiezon phases Hi-EFF -BP Reoplex 00 Apolane -87 Hi-EFF -AP SE-0 Butanediol succinate Hi-EFF -BP Squalane (Craig s polyester) Hi-EFF -BP Superox -FA Carbowax phases Hi-EFF -8BP XE-60 Table : Custom Dimensions Alltech Heliflex Custom Capillary Columns Description 5m 0.0mm Specify Phase and mm Specify Phase and Specify Phase and 9700 Specify Phase and mm Specify Phase and 9700 Specify Phase and m 0.0mm Specify Phase and mm Specify Phase and 970 Specify Phase and 9705 Specify Phase and mm Specify Phase and 9705 Specify Phase and m 0.0mm Specify Phase and mm Specify Phase and 9709 Specify Phase and 9700 Specify Phase and mm Specify Phase and 9700 Specify Phase and m 0.8mm Specify Phase and Specify Phase and Specify Phase and mm Specify Phase and Specify Phase and m Specify Phase and 9705 Specify Phase and mm Specify Phase and 9705 Specify Phase and Custom Capillary All other Dimensions not specified 970 Custom Capillary Coiling Custom Coiling Description Custom Capillary on " Cage 970 Custom Capillary Column with Integral Guard Custom Capillary Column with Integral Guard Description Custom with Integral 5m Guard C-500 Custom with Integral 5m Guard C-5500 Custom with Integral 5m Guard C

4 gas chromatography Heliflex AT -ms Heliflex AT -ht Guaranteed low-bleed characteristics Specifically designed for mass spec analysis Highly inert Similar to DB-ms, HP-ms, Rtx -ms, CP-Sil 5CB low-bleed/ms, MDN- AT -ms is a line of high-performance low bleed nonpolar columns designed specifically for use with mass spectrometers. They are ideal for pharmaceutical, environmental, petrochemical, and food and fragrance analysis, or any GC/MS analysis requiring a 00% dimethylpolysiloxane-type polarity capillary column. Heliflex AT -ms Specifications 00% Dimethylpolysiloxane Polarity: Non-polar Max. Temp.: 0/60 C USP Designation: G, G, G8 Ideal For: Mass Spec Analysis for Environmental, PAH, CLP Pesticides, Steroids, and Drugs Faster analysis time for high boiling compounds Better peak detection at lower concentrations Individually bleed tested at 80ºC Similar to 007-, CP-Sil 5CB, DB-, DB-ht, HP-, HP-0, OVTM-, RSL-50, RSL-60, Rtx -, SE-0, SPBTM-, SPBTM-Sulfur, ULTRA-, SP-00, BP-, DC-00, PE-, ZB- Heliflex AT -ht Specifications 00% Dimethylpolysiloxane Polarity: Non-polar Max. Temp.: 80/00 C USP Designation: G, G, G8 Ideal For: High Boiling Compounds Waxes, Crude Oils, and Trigylcerides Figure AT -ms Low Bleed QC Test Chromatogram Bleed Profile Ethylhexanoic Acid -Chlorophenol,7-Heptanediol n-tridecane -Undecanol n-tetradecane Dicyclohexylamine Acenaphthylene n-pentadecane pa m 60m Min. Column: Column Temp: Carrier Gas: Detector: Heliflex AT -ms Capillary Columns -Undecanol Dicyclohexylamine -Chlorophenol n-pentadecane Fluorene Anthracene n-heptadecane. pa 0 Min. Column: Heliflex AT -ms, 0m x x ( 5897) Temp: 5 C (0min hold) to 0 C (0min hold) at 0 C/min Carrier Gas: Helium at 0.65mL/min (.cm/sec) Detector: FID Shorten Your Analysis Time with High-Temperature/Low-Bleed Columns Heliflex AT -ht, 0m x x 0.0µm ( 668) 5ºC (5min hold) to 80ºC at 0ºC/min Helium at 6.cm/sec FID at 90ºC Heliflex AT -ht GC Capillary Columns min. max. 0.0µm C C C C C * min. max m 0m 60m 0.µm 0.µm 0.µm /00 C /00 C /00 C *Isothermal/Temp. program.

5 Heliflex AT - Excellent general purpose columns Similar to DB-, Rtx -, SPB -, SPB -Sulfur, SP-00, HP-, HP-0, ULTRA-, BP-, CP-Sil 5CB, 007-, OV-, SE -0, DC-00, RSL-50, RSL-60, PE-, ZB- Heliflex AT - Specifications 00% Dimethylpolysiloxane Polarity: Non-polar General Purpose Column USP Designation: G, G, G8 Ideal For: General Purpose Econo-Cap EC - Batch tested to dramatically reduce price value Econo-Cap EC - Capillary Columns 0m C C C µm C 9656 Heliflex AT - Capillary Columns 0m 0.0µm C µm C C µm C C 680.0µm C µm C µm C 68 5m 0.0µm C C C µm C C C µm C µm C 95.0µm C µm 60 0 C µm C µm C 685 5m 0.0µm C µm C 95 0m 0.0µm C C C C µm C C 6.00µm C µm C µm C C 55.0µm C µm 60 0 C 908 0m.65µm C µm C µm C 68 50m 0.0µm C m C C µm C C µm C µm C 70.00µm C µm C 80 00m C 97 best value Econo-Cap EC - Capillary Columns, Six Pack 0m C m C m.0µm C

6 gas chromatography Heliflex AT -5ms Heliflex AT -5 Similar to DB-5ms, Rtx -5 Sil ms, HP-5TA, BPX -5, 007-5ms Excellent general purpose columns Similar to DB-5, Rtx -5, SPB -5, HP-5, ULTRA-, BP-5, CP-Sil 8CB, 007-, OV -5, SE -5, SE -5, RSL-00, ZB-5 The AT -5ms capillaries are ideal for environmental, pharmaceutical, and petrochemical analysis, or any GC/MS analysis requiring a 5% phenyl-type polarity capillary column. Heliflex AT -5ms Specifications (5% Phenyl)-95% Methoxpolysiloxane Polarity: Non-polar USP Designation: G7, G6 Ideal For: Mass Spec Analysis General Application Heliflex AT -5 Specifications (5% Phenyl)-95% Methylpolysiloxane Polarity: Non-polar Max. Temp.: 80/00 C USP Designation: G7, G6 Ideal For: General Applications Organophosphorus Pesticides Heliflex AT -5 Capillary Columns TEPP. Famphur 6. EPN Sulfotepp. Carbophenothion 7. Leptophos Monocrotophos 5. Phosmet 8. Azinphos-ethyl Dimethoate 8 Dioxathion 9 Terbufos 6 Phosphamidon Malathion Parathion 6 cis-chlorfenvinphos 7 trans-chlorfenvinphos 5 8 Ethion 0m 5m 5m 0m Column: Temp: Carrier Gas: Detector: Min. Heliflex AT -5ms, 0m x x ( 5807) 0 C (min hold) to 85 C at 5 C/min (min hold) Helium, 6cm/sec MSD 60m Heliflex AT -5ms Capillary Columns 5m 0m 60m * min. max. 0.0µm 0.50µm 0.50µm 0.0µm 00m * * * min. max..65µm.0µm.50µm 0.0µm 0.0µm 0.50µm 0.50µm.0µm.50µm.65µm 5.00µm.0µm 5.00µm C 60 0 C 60 0 C C 60 0 C C C C C C C C C C Heliflex AT -0 Unique polarity between non-polar and mid-range Similar to 007-7, Rtx -0, SPBTM-0, VOCOLTM, PE-7 Heliflex AT -0 Specifications (0% Phenyl)-80% Methylpolysiloxane Polarity: Intermediate Polarity USP Designation: G8, G Ideal For: Volatile Compounds and Solvents Heliflex AT -0 Capillary Columns *Isothermal/Temp. program. 5m 0m 6 min. max..0µm 0 0 C 0 0 C 0 00 C 0 00 C

7 Econo-Cap EC -5 Batch tested to dramatically reduce price value Econo-Cap EC -5 Capillary Columns 5m.0µm C 965 0m C C C 967.0µm C 9657 best value Econo-Cap EC -5 Capillary Columns, Six Pack 0m C C µm C

8 gas chromatography Heliflex AT -5ms Heliflex AT -5 Guaranteed low-bleed Specifically designed for mass spec analysis Similar to DB-5ms, Rtx -5, SPBTM-5, Sup-HerbTM, MDN-5, BPX -5 Ideal column for conformational analysis Similar to DB-5, DB-5ms, Rtx -5, BPX -5, SPB -5, SPB -608, HP-5, 007-, OV -, RSL-00, PE-5, Sup-HerbTM, ZB-5 Heliflex AT -5ms Specifications (5% Phenyl)-65% Methylpolysiloxane Polarity: Intermediate Polarity USP Designation: G Ideal For: Pesticides, Herbicides, Drugs, Aromatics Heliflex AT -5 Specifications (5% Phenyl)-65% Methylpolysiloxane Polarity: Intermediate Polarity USP Designation: G Ideal For: Pesticides, Herbicides, Drugs, Aromatics Heliflex AT -5ms Capillary Column Heliflex AT -5 Capillary Columns min. max C -0 0 C 0m 60m m 5m 5m 0m Tocopherols m d-δ-tocopherol d-β-tocopherol d-γ-tocopherol d-α-tocopherol min. max..0µm.65µm.0µm.0µm 0.50µm.0µm.65µm C C C C -0 0 C C -0 0 C -0 0 C C C C -0 0 C -0 0 C Column: Temp: Carrier: Detector: 5 6 Min. Heliflex AT -5, 5m x x 0.0µm ( 9655) 0 C Hydrogen at 0cm/sec FID 8

9 Heliflex AT -50 General purpose column Similar to DB-7, DB-7ht, Rtx -50, BPX TM -50, SPB TM -50, SP-50, HP-50+, HP-7, 007-7, OV -7, CP-Sil CB, PE-7, ZB-50 Heliflex AT -0 Unique polarity makes it ideal for a range of applications Similar to BP6, DB-0, Rtx -0, Rtx -6, HP-0, HP-6, DB-6, 007-6, 007-0, SPB -0, SPB TM -6, ZB-6 Heliflex AT -50 Specifications (50% Phenyl)-Methylpolysiloxane Polarity: Intermediate Polarity USP Code: G Ideal For: Pesticides, Herbicides, Phthalate Esters, Free Phenols, and Basic Drugs Heliflex AT -0 Specifications (6% Cyanopropylpenyl)-Methylpolysiloxane Polarity: Intermediate Polarity USP Code: G Ideal For: Volatile Organics, Pharmaceuticals, and EPA Method 6 Heliflex AT -50 Capillary Columns 5m 0 5 C C 876 0m 0 5 C C µm 0 00 C C 878 Heliflex AT -0 Capillary Columns 0m C µm C

10 Heliflex AT -0 Similar to DB- 0, Rtx -00, OV - 0, OV -0, OV -5, QF-, SP-0, RSL-00 Heliflex AT -70 Similar to DB-70, OV -70, SPB -70, Rtx -70, , PAS-70, CP-Sil 9CB, HP-70, BP-0, ZB-70 Heliflex AT -0 Specifications Trifluoropropyl Methylpolysiloxane Polarity: Polar USP Code: G6 Ideal For: Ketones, Aldehydes, Silanes, Glycols, Nitro Aromatics, Herbicides, and Method 80 and 609 Heliflex AT -70 Specifications (% Cyanopropylphenyl)-86% Methylpolysiloxane Polarity: Intermediate Polarity USP Code: n/a Ideal For: Pesticides, PCB s, Drugs, Herbicides, and TMS Sugars Heliflex AT -0 Capillary Columns 5m 5 0 C 7.0µm 5 0 C m 5 0 C 6.0µm 5 0 C 9850 EPA Method 55.: Haloacetic Acids 05 Heliflex AT -70 Capillary Columns 5m C C 76 0m C C C C C 795.0µm C 80 60m C C C C C. Monochloroacetic Acid. Monobromoacetic Acid. Dalapon. Dichloroacetic Acid 5. Trichloroacetic Acid 6. Bromochloroacetic Acid 7. Dibromoacetic Acid Min. Column: Temp: Carrier Gas: Detector: Heliflex AT -70, 0m x x ( 690) 50 C (0min hold) to 0 C at 0 C/min Helium at 5cm/sec ECD 0

11 Heliflex AT -WAXms Designed to provide low MS bleed Similar to DB-WAX, Rtx -WAX, Supelcowax TM -0 Heliflex AT -WAX Similar to DB-WAX, DB-WAXetr, Rtx -WAX, Stabilwax, Carbowax 0M, Supelcowax TM -0, Innowax, HP-0M, HP-Wax, BP-0, CP-Wax 5-CB, 007-CW, Superox II, OmegaWAX, ZB-WAX Heliflex AT -WAXms Specifications 00% Polyethylene Glycol Polarity: Polar USP Code: G, G5, G6, G9 Ideal For: Mass Spec Analysis Heliflex AT -WAX Specifications 00% Polyethylene Glycol Polarity: Polar USP Code: G, G5, G6, G9 Ideal For: FAMEs, Polar Solvents, BTEX, Flavor and Fragrances, Glycols, Alcohols, and Aromatics Heliflex AT -WAXms Capillary Columns 0m 0 60 C C m 0 60 C 605 Heliflex AT -WAX Capillary Columns 0m.0µm 0 60 C m 0.50µm 0 60 C µm 0 60 C C 76 5m 0.50µm 0 60 C C 90.0µm 0 60 C m 0.0µm 0 80 C µm 0 80 C 995.0µm 0 60 C m 0.0µm 0 80 C C µm 0 60 C C µm 0 80 C µm 0 60 C C µm 0 60 C 0 60 C 907.0µm 0 60 C m 0.0µm 0 80 C µm 0 60 C 96 60m 0.0µm 0 80 C C C µm 0 80 C µm 0 60 C C 99.0µm 0 60 C 850

12 gas chromatography Econo-Cap EC -WAX Batch tested to dramatically reduce price For phase specifications, see Heliflex AT version Heliflex AT -AquaWax-DA Designed and tested for aqueous injections Eliminates the need for derivatization of acidic organic compounds Similar to DB-FFAP, Stabilwax, HP-FFAP-DA, ZB-FFAP, SPBTM-000, and Nukol value Econo-Cap EC -WAX Capillary Columns 5m 0m min. max..0µm.0µm 0 60 C 0 80 C 0 80 C 0 60 C Econo-Cap EC -WAX Six-Pack Capillary Columns 0m min. max..0µm 0 60 C 0 60 C 0 60 C Heliflex AT -AquaWax-DA Specifications 00% Polyethylene Glycol Nitroterephthal Acid Modified Polarity: Polar USP Code: n/a Ideal For: Analysis of Acidic Organic Compounds and Free Fatty Acids Heliflex AT -AquaWax-DA Capillary Columns best value m 60m min. max C 0 50 C 0 50 C 0 50 C more info Free Fatty Acids For more information on the Econo-Cap Capillary Line, refer to page. 58 Heliflex AT -AquaWax Designed and tested for aqueous injections Similar to DB-Wax, DB-Waxer, Rtx -WAX, Stabilwax, HP-Wax, HP-0M, HP-Innowax, ZB-Wax, and SupelcowaxTM-0 0 0m 60m min. max C 0 60 C 0 60 C 0 60 C Propionic Acid Butyric Acid Valeric Acid Caproic Acid Heptanoic Acid Caprylic Acid 0 Min. Column: Heliflex AT -AquaWax-DA, 0m x x ( 57) Temp: 80 C Carrier Gas: Helium at cm/sec Detector: FID Heliflex AT -AquaWax Capillary Columns Heliflex AT -AquaWax Specifications 00% Polyethylene Glycol Polarity: Polar USP Code: n/a Ideal For: Food and Beverage Analysis

13 Heliflex AT -000 Similar to DB -FFAP, Stabilwax -DA, SPB -000, Nukol, HP-FFAP, BP-, CP-Wax-58-CB, 007-FFAP, OV -5, FFAP, Superox -FA, ZB-FFAP Heliflex AT -000 Specifications 00% Polyethylene Glycol Acid Modified Polarity: High Polarity USP Code: G5, G5 Ideal For: Free Fatty Acids Heliflex AT -000 Capillary Columns 0m.0µm 0 50 C m 0 50 C 87.0µm 0 50 C m 0.0µm 0 50 C µm 0 50 C 975 0m 0 50 C C µm 0 50 C C 877.0µm 0 50 C µm 0 50 C 07 50m 0.0µm 0 50 C µm 0 50 C m 0 50 C C µm 0 50 C C C 879 Heliflex AT -FAME Similar to FAMEWAX and OmegaWAX Heliflex AT -FAME Specifications Stable Bonded Polyethylene Glycol Polarity: High Polarity USP Code: G5, G5 Ideal For: Fatty Acid Methyl Esters Heliflex AT -FAME Capillary Columns 0m 0 80 C C 8 Econo-Cap EC -000 Batch tested to dramatically reduce price For phase specifications, see Heliflex AT version value Econo-Cap EC -000 Capillary Columns 5m.0µm 0 50 C 968 0m 0 50 C C µm 0 50 C 9688 best value Econo-Cap EC -000 Six-Pack Capillary Columns 0m 0 50 C µm 0 50 C

14 Heliflex AT -6 Specially tested for EPA Method 6 Similar to DB -0, Rtx -0, Rtx -6, HP-0, HP-6, DB -6, 007-6, 007-0, SPB -0, SPB -6, ZB-6 Heliflex AT -5 Similar to DB -5, HP-5, Rtx -5, OV -5, RSL-500, 007-5, CP-Sil CB, BP-5, PE-5 Heliflex AT -6 Specifications 6% Cyanopropylphenyl-9% Methylpolysiloxane Polarity: Intermediate Polarity USP Code: G Ideal For: EPA Methods 5, 60, 60, 6, 80 and 860, and Solvent Analysis Heliflex AT -5 Specifications (50% Cyanopropylphenyl)-50% Methylpolysiloxane Polarity: Mid to High Polarity USP Code: G9 Ideal For: Carbohydrates and Solvents Heliflex AT -6 Capillary Columns 0m.0µm C 75.80µm C µm C µm C m.0µm C 50.80µm C µm C m.00µm C 97 EPA Method 60 Purgeable Aromatics Heliflex AT -5 Capillary Columns 5m 0 0 C 88 5m 0.0µm 0 0 C 955 0m 0 0 C C µm 0 0 C 90.0µm 0 0 C Benzene. Toluene. Chlorobenzene. Ethylbenzene 5.,-Dichlorobenzene 7 6.,-Dichlorobenzene 7.,-Dichlorobenzene Min. Column: Temp: Carrier Gas: Detector: Heliflex AT -6, 0m x x.80µm ( 756) 90 C (7min hold) to 80 C at 0 C/min Helium at.ml/min FID

15 Heliflex AT -Silar-90 Designed and tested for FAME Similar to DB -, CP-Sil 8, Rtx -0, SP-0 Heliflex AT -Silar-00 Ideal for high and low temperature separation of samples containing geometric isomers of FAMEs Similar to CO-Sil 88, Rtx -0, SP-0 Heliflex AT -Silar-90 Specifications Poly (90% bis Cyanopropyl)-0% Cyanopropyphenyl Siloxane Polarity: High Polarity USP Code: G8 Ideal For: Analysis of FAMEs Heliflex AT -Silar-00 Specifications Poly bis Cyanopropyl Polarity: High Polarity Available USP Code: G8 Ideal For: cis/trans Isomers of FAMEs, Dioxins, and Furans Heliflex AT -Silar-90 Capillary Columns 5m 0.0µm 0 50 C 67 0m 0.0µm 0 50 C µm 0 50 C Fatty Acid Methyl Esters C:0. C6:0. C6:. C8: 5. C8: 6. C8: 7. C8: 8. C0: 9. C0: C0:. C0:5. C:. C:5. C:6 Heliflex AT -Silar-00 Capillary Columns 5m 0.0µm 0 50 C 6 0m 0.0µm 0 50 C 6 0.0µm 0 50 C 6 Fatty Acid Methyl Esters in Rapeseed Oil C:0. C6:0. C8:0. C8: 5. C8: 6. C0: C0: 8. C8: 9. C:0 0. C: Min Min. Column: Heliflex AT -Silar-90, 0m x x 0.0µm ( 09) Temp: 00 C Carrier Gas: Helium at 0cm/sec Detector: FID Column: Heliflex AT -Silar-00, 0m x x 0.0µm ( 0) Temp: 90 C Carrier Gas: Helium at 0cm/sec Detector: FID 5

16 Heliflex AT -Amino Acid Separates all 0 essential amino acids Heliflex AT -Amino Acid Specifications Proprietary Polarity: Intermediate USP Code: n/a Ideal For: Amino Acids Heliflex AT -Amino Acid Capillary Column 5m.0µm C 686 N(O,S)-Heptafluorobutyl-isobutyl Esters of Amino Acids from Soy Protein Hydrolysate. Alanine. Glycine. Valine. Threonine 5. Serine 6. Leucine 7. Isoleucine 8. Proline 9. Cystine 0. Methionine. Aspartic Acid. Phenylalanine Glutamic Acid. Lysine 5. Tyrosine 6. Arginine 7. Histidine 8. Tryptophan Min. Column: Temp: Carrier Gas: Detector: Heliflex AT -Amino Acid, 5m x x.0µm ( 686) 80 C (min hold) to 0 C at C/min Helium at 0mL/min FID 6

17 Heliflex AT -50. Separates early eluting gases at above ambient temperature Useful for volatile organics analysis, including EPA Methods 50., 5., 860 Heliflex AT -50. Specifications Proprietary Polarity: Intermediate USP Code: n/a Ideal For: Volatile Organics and EPA Methods 50., 5., and 860 Heliflex AT -50. Capillary Columns Temp. Limit max. 60m.0µm 70 C µm 70 C µm 70 C 79 05m.80µm 70 C 79.00µm 70 C TCLP Volatiles Mix Vinyl Chloride.,-Dichloroethene. -Butanone. Chloroform 5. Carbon Tetrachloride 6. Benzene +,-Dichloroethene 7. Trichloroethene 8. Tetrachloroethene 9. Chlorobenzene 0.,-Dichlorobenzene Min. Column: Temp: Carrier Gas: Detector: Heliflex AT -50., 0m x x.00µm ( 79) 0 C (0min hold) to 0 C at C/min Helium at cm/sec FID 7

18 Heliflex AT -Sulfur Designed for the analysis of volatile sulfurcontaining compounds in petroleum distillates Heliflex AT -Sulfur Specifications 00% Methylpolysiloxane Polarity: Non-Polar USP Code: n/a Ideal For: Volatile Sulfur Compounds Heliflex AT -Sulfur Capillary Columns Temp. Limit min. max. 0m.00µm C 09 Heliflex AT -70 For boiling range of gasoline samples Heliflex AT -70 Specifications 00% Methylpolysiloxane Polarity: Non-Polar USP Code: n/a Ideal For: Boiling Point of Gasoline Heliflex AT -70 Capillary Column Temp. Limit max. 5m 5.00µm 00 C 99 Heliflex AT -Petro For high resolution of complex hydrocarbon mixtures Heliflex AT -Petro Specifications 00% Methylpolysiloxane Polarity: Non-Polar USP Code: n/a Ideal For: hydrocarbon Mixtures Heliflex AT -Petro Capillary Column Temp. Limit max. 00m 0.50µm 50 C

19 Alltech Column Guide to EPA Methods Alltech Guide to Capillary Columns for Environmental Analysis Method Description and Recommended Columns Comments 50. Trihalomethanes in Drinking Water Heliflex AT -6, 0m x x.00µm Volatile Halogenated Organics by Purge and Trap GC/ELCD Heliflex AT -6, 0m x x.00µm Subambient 6889 Heliflex AT -6, 60m x x.00µm Ambient Volatile Organics in Water by Purge and Trap GC/PID/ELCD Heliflex AT -50., 05m x x.00µm 79 Heliflex AT -6, 60m x x.00µm DBE and DBCP by Microextraction GC/ECD Econo-Cap EC -, 0m x x (Inexpensive, Batch QC ed Column) Organohalide Pesticides and PCBs by Microextraction and GC/ECD Heliflex AT -, 0m x x Primary Column Phthalate and Adipate Esters in Water (GC/PID) Heliflex AT -, 0m x x 60 Heliflex AT -5, 0m x x Nitrogen and Phosphorus Containing Pesticides by GC/NPD Heliflex AT -5, 0m x x Primary Column 656 Econo-Cap EC -5, 0m x x (Inexpensive, Batch QC ed Column) 967 Heliflex AT -70, 0m x x Confirmation Column Chlorinated Pesticides by GC/ECD Heliflex AT -5, 0m x x Primary Column 656 Econo-Cap EC -5, 0m x x (Inexpensive, Batch QC ed Column) 967 Heliflex AT -70, 0m x x Alternate Column Chlorinated Acids by GC/ECD Heliflex AT -5, 0m x x Primary Column 656 Econo-Cap EC -5 Econo-Cap, 0m x x (Inexpensive, batch QC ed column) 967 Heliflex AT -70, 0m x x Confirmation Column Purgeables by Purge and Trap GC/MS Heliflex AT -6, 0m x x.00µm Subambient (0 C) 6889 Heliflex AT -6, 60m x x.00µm Ambient 800 Heliflex AT -5, 0m x x Subambient, Cryofocusing 659 Heliflex AT -5, 0m x x Subambient, Cryofocusing Organic Compounds in Water by Liquid-Solid Extraction and Capillary GC/MS Heliflex AT -5ms, 0m x x 589 Heliflex AT -5ms, 0m x x Endothall in Drinking Water Heliflex AT -, 0m x x 68 Heliflex AT -5, 0m x x Chlorination Disinfection By-products and Chlorinated Solvents in Drinking Water Heliflex AT -, 0m x x 6 Econo-Cap EC -, 0m x x (Inexpensive, Batch QC ed Column) Haloacetic Acids in Drinking Water Heliflex AT -70, 0m x x

20 Alltech Column Guide to EPA Methods (continued) Alltech Guide to Capillary Columns for Environmental Analysis (continued) Method Description and Recommended Columns Comments 60 Purgeable Halocarbons by Purge and Trap ELCD Heliflex AT -6, 0m x x.00µm Subambient 6889 Heliflex AT -6, 60m x x.00µm Ambient Purgeable Aromatics by Purge and Trap GC/PID Heliflex AT -6, 0m x x.00µm 6889 Econo-Cap EC -WAX, 0m x x.0µm (Inexpensive, Batch QC ed Column) Acrolein and Acrylonitrile by GC/FID Heliflex AT -6, 0m x x.00µm Phenols by GC/FID and GC/ECD Heliflex AT -5, 0m x x.0µm 9550 Econo-Cap EC -5, 0m x x.0µm (Inexpensive, Batch QC ed Column) 9657 Heliflex AT -5, 0m x x 658 Econo-Cap EC -5, 0m x x (Inexpensive, Batch QC ed Column) 966 Heliflex AT -5, 0m x x 656 Econo-Cap EC -5, 0m x x (Inexpensive, Batch QC ed Column) Phthalate Esters by GC/ECD Heliflex AT -5, 5m x x.0µm 9555 Econo-Cap EC -5, 5m x x.0µm (Inexpensive, Batch QC ed Column) Nitrosamines Heliflex AT -5, 5m x x.0µm 9555 Econo-Cap EC -5, 5m x x.0µm (Inexpensive, Batch QC ed Column) Nitroaromatics and Isophorone by GC/FID and GC/ECD Heliflex AT -5, 5m x x.0µm (Capillary GC) Polynuclear Aromatic Hydrocarbons by GC/FID Heliflex AT -5, 0m x x.0µm 9550 Econo-Cap EC -5, 0m x x.0µm (Inexpensive, Batch QC ed Column) 9657 Heliflex AT -5, 0m x x Polynuclear Aromatic Hydrocarbons by HPLC and GC/FID Heliflex AT -5, 0m x x 658 Econo-Cap EC -5, 0m x x (Inexpensive, Batch QC ed Column) 966 Heliflex AT -5, 0m x x 656 Econo-Cap EC -5, 0m x x (Inexpensive, Batch QC ed Column) Haloethers by GC/HSD Heliflex AT -5, 5m x x.0µm 9555 Econo-Cap EC -5, 5m x x.0µm (Inexpensive, Batch QC ed Column) Chlorinated Hydrocarbons by GC/ECD Heliflex AT -5, 5m x x.0µm 9555 Econo-Cap EC -5, 5m x x.0µm (Inexpensive, Batch QC ed Column) Chlorinated Herbicides by GC/ECD/ELCD Heliflex AT -, 0m x x 60 Econo-Cap EC -, 0m x x (Inexpensive, Batch QC ed Column) Triazine Herbicides Heliflex AT -50, 0m x x Purgeables by Purge and Trap GC/MS Heliflex AT -6, 0m x x.00µm Subambient (0 C) 6889 Heliflex AT -6, 60m x x.00µm Ambient 800 Heliflex AT -5, 0m x x Subambient, Cryofocusing 659 Heliflex AT -5, 0m x x Subambient, Cryofocusing Base/Neutral and Acids by GC/MS See Method Pesticides and PCBs in Water and Soil/Sediment by GC/MS Heliflex AT -5ms, 0m x x EDB and DBCP by Microextraction Using GC Heliflex AT -, 0m x x

21 Alltech Column Guide to EPA Methods (continued) Alltech Guide to Capillary Columns for Environmental Analysis (continued) Method Description and Recommended Columns Comments 805 Nonhalogenated Volatile Organics Heliflex AT -WAX, 0m x x 907 Heliflex AT -5, 0m x x.50µm Acrylamide by GC/ECD Heliflex AT -000, 5m x x.0µm Acetonitrile by GC/NPD Heliflex AT -WAX, 5m x x Phenols by GC/FID/(ECD) Heliflex AT -5, 0m x x.50µm 909 Heliflex AT -70, 0m x x Nitrosamines Heliflex AT -5, 5m x x.0µm 9555 Econo-Cap EC -5, 5m x x.0µm (Inexpensive, Batch QC ed Column) Organochlorine Pesticides by GC/ECD Heliflex AT -5, 0m x x 657 Heliflex AT -5, 0m x x 796 Heliflex AT -70, 0m x x 795 Heliflex AT -5, 0m x x.50µm Polychlorinated Biphenyls (PCBs) by GC/ECD or GC/ELCD Heliflex AT -5, 0m x x 657 Heliflex AT -5, 0m x x 796 Heliflex AT -70, 0m x x 795 Heliflex AT -5, 0m x x.50µm Nitroaromatics and Cyclic Ketones by GC/ECD or GC/NPD Heliflex AT -5, 0m x x.50µm 909 Heliflex AT -70, 0m x x Polynuclear Aromatic Hydrocarbons by GC/FID Heliflex AT -5, 0m x x.0µm 9550 Econo-Cap EC -5, 0m x x.0µm (Inexpensive, Batch QC ed Column) 9657 Heliflex AT -5, 0m x x 658 Econo-Cap EC -5, 0m x x (Inexpensive, Batch QC ed Column) 966 Heliflex AT -5, 0m x x 656 Econo-Cap EC -5, 0m x x (Inexpensive, Batch QC ed Column) Haloethers by GC/ECD Heliflex AT -5, 0m x x.50µm 909 Heliflex AT -70, 0m x x.0µm 80 8 Organophosphorus Pesticides by GC/NPD/FPD/ELCD Heliflex AT -0, 5m x x.0µm Column 9855 Heliflex AT -5, 5m x x.0µm Column 9555 Econo-Cap EC -5, 5m x x.0µm (Inexpensive, Batch QC ed Column) Chlorinated Herbicides by GC/ECD Using Methylation and Pentafluorobenzylation Derivatization Heliflex AT -5, 0m x x 656 Heliflex AT -5, 0m x x 659 Heliflex AT -5, 0m x x 6 Heliflex AT -70, 0m x x 686 Heliflex AT -70, 0m x x Volatile Organics by GC/MS: Capillary Column Technique Heliflex AT -6, 0m x x.00µm Subambient (0 C) 6889 Heliflex AT -6, 60m x x.00µm Ambient 800 Heliflex AT -5, 0m x x Subambient, Cryofocusing 659 Heliflex AT -5, 0m x x Subambient, Cryofocusing 657 Heliflex AT -50., 60m x x.00µm Ambient 79 Heliflex AT -50., 05m x x.00µm Ambient 79

GC Section. Astec, Agilent/J&W, SGE, Quadrex

GC Section. Astec, Agilent/J&W, SGE, Quadrex GC Section GC Columns..............................328-384 Introduction..............................329-330 Capillary Columns, Alltech................331-352 Custom Columns.......................... 331

More information

Agilent J&W GC Column Selection Guide SPEED YOUR SELECTION WITH THIS ONE-STOP RESOURCE

Agilent J&W GC Column Selection Guide SPEED YOUR SELECTION WITH THIS ONE-STOP RESOURCE Agilent J&W GC Column Selection Guide SPEED YOUR SELECTION WITH THIS ONE-STOP RESOURCE Table of Contents The story behind Agilent J&W Advanced GC Columns... 1 Column Selection Principles... 3 Selecting

More information

Agilent J&W GC Column Selection Guide

Agilent J&W GC Column Selection Guide Agilent J&W GC Column Selection Guide Rely on unsurpassed reproducibility, efficiency, and inertness. Speed your selection with this one-stop resource. Agilent J&W GC Column Selection Guide Table of Contents

More information

How To Select the Correct GC Column. Simon Jones Application Engineer

How To Select the Correct GC Column. Simon Jones Application Engineer How To Select the Correct GC Column Simon Jones Application Engineer Things to Consider Is it Volatile enough to chromatograph by GC? Is it a Gas or a Liquid? How are we getting the Sample Injected? What

More information

The Suite for Environmental GC Analysis

The Suite for Environmental GC Analysis The Suite for Environmental GC Analysis SGE Environmental GC Columns Performance Selectivity Delivery Promise www.sge.com SGE Environmental GC Columns The Suite for Environmental GC Analysis SGE GC Columns

More information

Understanding the Capillary GC Column: How to Choose the Correct Type and Dimension

Understanding the Capillary GC Column: How to Choose the Correct Type and Dimension Understanding the Capillary GC Column: How to Choose the Correct Type and Dimension Simon Jones Application Engineer Things to Consider Is it Volatile enough to chromatograph by GC? Is it a Gas or a Liquid?

More information

The BIG GC Special. Details, Playoff Specials, and Early Bird Discounts Inside! Expires: December 20, 2013 Mention Offer Code: ZBNF1213.

The BIG GC Special. Details, Playoff Specials, and Early Bird Discounts Inside! Expires: December 20, 2013 Mention Offer Code: ZBNF1213. The BIG GC Special Details, Playoff Specials, and Early Bird Discounts Inside! Exclusive Savings on Zebron GC Columns for any phase new to your company* Length 10-15 Meter 30 Meter 60 Meter Sale Price

More information

EPA Test Methods for GC

EPA Test Methods for GC EPA Test Methods for GC Method # Description 0016B Total Reduced Sulfur - (GC Analysis) 0018 VOC - GC 0311 HAPS in Paints & Coatings - Direct Injection GC 0312A Residual Styrene in SBR Latex by GC 0312B

More information

Fast, Accurate Environmental Testing

Fast, Accurate Environmental Testing GC Columns Fast, Accurate Environmental Testing Using Zebron GC Columns Featuring Pesticides Diesel Range Organics Semivolatiles Dioxane And more.. www.phenomenex.com/environmental Semi-Volatile Organic

More information

BP1 PONA BPX1. GC Capillary Columns BP1 PONA and BPX1

BP1 PONA BPX1. GC Capillary Columns BP1 PONA and BPX1 GC Capillary Columns 100% Dimethyl Polysiloxane GC Columns and Applications ID (mm) Film Thickness (µm) Length (m) Temperature Limits ( C) Part No. 0.32 0.5 60-60 to 320/340 054069 0.32 1 60-60 to 320/340

More information

Slightly Polar Columns

Slightly Polar Columns 9000 Варна, ул.поп Харитон 47 e-mail : gea99@abv.bg www.geya99.com Slightly Polar Columns With the partnership of Teknokroma SLIGHTLY POLAR COLUMNS TRB-5 It is the most universal and versatile stationary

More information

So Many Columns! How Do I Choose? Daron Decker Chromatography Technical Specialist

So Many Columns! How Do I Choose? Daron Decker Chromatography Technical Specialist So Many Columns! How Do I Choose? Daron Decker Chromatography Technical Specialist GC Columns Wall Coated Open Tubulars Liquid phase coated capillaries Internal Diameter 0.05 0.53mm Length 5m 100m Porous

More information

Choosing the Correct GC Column Dimensions and Stationary Phase

Choosing the Correct GC Column Dimensions and Stationary Phase Choosing the Correct GC Column Dimensions and Stationary Phase Daron Decker Chromatography Technical Specialist Page 1 Nothing is useless it can always serve as a bad example Custom Column: 150 m x 250

More information

Appendices References...49 Glossary Equations

Appendices References...49 Glossary Equations Table of Contents List of Tables...2 List of Figures...2 Column Selection General Considerations for Column Selection... 3-11 Your Zebron Capillary GC Column... 12-29 Column Installation Pre-Installation

More information

Accurate, Reproducible Results for Environmental Methods with Zebron GC Columns

Accurate, Reproducible Results for Environmental Methods with Zebron GC Columns Accurate, Reproducible Results for Environmental Methods with Zebron GC Columns BUY NOW AND SAVE! Length Sale Price* 10-15 meter $ 199 30 meter $ 399 60 meter $ 599 *Offer valid only for addressee, limit

More information

New Gs BP GC Columns

New Gs BP GC Columns New Gs BP GC Columns GS-Tek What really makes GsBP GC columns different from other brand name columns? GsBP columns are developed and made in USA with proprietary manufacturing processes developed by column

More information

Theory and Instrumentation of GC. GC Columns

Theory and Instrumentation of GC. GC Columns Theory and Instrumentation of GC GC Columns i Wherever you see this symbol, it is important to access the on-line course as there is interactive material that cannot be fully shown in this reference manual.

More information

GAS CHROMATOGRAPHY. Mobile phase is a gas! Stationary phase could be anything but a gas

GAS CHROMATOGRAPHY. Mobile phase is a gas! Stationary phase could be anything but a gas GAS CHROMATOGRAPHY Mobile phase is a gas! Stationary phase could be anything but a gas Gas Chromatography (GC) GC is currently one of the most popular methods for separating and analyzing compounds. This

More information

Introduction and Principles of Gas Chromatography

Introduction and Principles of Gas Chromatography Introduction and Principles of Gas Chromatography Jaap de Zeeuw Restek, Middelburg, The Netherlands Jaap.dezeeuw@restek.com Definition and Uses of Gas Chromatography GC Components and Types of Columns

More information

D2245

D2245 GC Columns and Accessories Thermo Scientific Chromatography Columns and Consumables 2014-2015 GC Column Selection by ASTM Method Selected ASTM methods are listed below with the appropriate Thermo Scientific

More information

A New PEG GC Column with Improved Inertness Reliability and Column Lifetime Agilent J&W DB-WAX Ultra Inert Polyethylene Glycol Column

A New PEG GC Column with Improved Inertness Reliability and Column Lifetime Agilent J&W DB-WAX Ultra Inert Polyethylene Glycol Column A New PEG GC Column with Improved Inertness Reliability and Column Lifetime Agilent J&W DB-WAX Ultra Inert Polyethylene Glycol Column Competitive Comparison Authors Ngoc-A Dang and Allen K. Vickers Agilent

More information

Selection of a Capillary

Selection of a Capillary Selection of a Capillary GC Column - Series 3 Mark Sinnott Application Engineer March 19, 2009 Page 1 Typical Gas Chromatographic System Mol-Sieve Traps Fixed Restrictors Regulators Injection Port Detector

More information

Rtx -CLPesticides Columns Reduce Analysis Time; Reduce System Maintenance

Rtx -CLPesticides Columns Reduce Analysis Time; Reduce System Maintenance Columns Reduce Analysis Time; Reduce System Maintenance 0 YEARS Turning Visions into Reality www.restek.com 00-- --00 and Fused Silica Columns Detect and confirm 0 common organochlorine pesticides simultaneously.

More information

Selection of a Capillary GC Column

Selection of a Capillary GC Column Selection of a Capillary GC Column Mark Sinnott Application Engineer March 13, 2008 Page 1 Typical Gas Chromatographic System Mol-Sieve Traps Fixed Restrictors Regulators Injection Port Detector Electrometer

More information

USP <467> Headspace Residual Solvent Assay with a HT3 Headspace Instrument

USP <467> Headspace Residual Solvent Assay with a HT3 Headspace Instrument Application Note Abstract The US Pharmacopeia recently released USP as the current monograph for determining residual solvents in pharmaceutical products by static headspace. The USP classified these

More information

METHOD 3600C CLEANUP

METHOD 3600C CLEANUP METHOD 3600C CLEANUP 1.0 SCOPE AND APPLICATION 1.1 Method 3600 provides general guidance on selection of cleanup methods that are appropriate for the target analytes of interest. Cleanup methods are applied

More information

METHOD 3600B CLEANUP

METHOD 3600B CLEANUP METHOD 3600B CLEANUP 1.0 SCOPE AND APPLICATION 1.1 Method 3600 provides general guidance on selection of cleanup methods that are appropriate for the target analytes of interest. Cleanup methods are applied

More information

GC COLUMN GUIDE. Powerful Gas Chromatography and Chromatography Data System Solutions

GC COLUMN GUIDE. Powerful Gas Chromatography and Chromatography Data System Solutions COLUMN GUE Powerful Gas Chromatography and Chromatography Data System Solutions Column Reference Guide Column Reference guide by phase SCION Column Phase Composition/Porous Layer Application SCION-1MS

More information

Study of Residual Solvents in Various Matrices by Static Headspace

Study of Residual Solvents in Various Matrices by Static Headspace Application Note Abstract United States Pharmacopeia (USP) chapter is a widely used method for identifying and quantifying Organic Volatile Impurities (OVI) used in the production of pharmaceuticals.

More information

Capillary GC Column Selection and Method Development A Primer on Column Parameters and Instrument Conditions

Capillary GC Column Selection and Method Development A Primer on Column Parameters and Instrument Conditions Capillary GC Column Selection and Method Development A Primer on Column Parameters and Instrument Conditions Michael D. Buchanan September 11, 2014 sigma-aldrich.com/analytical 2012 Sigma-Aldrich Co. All

More information

Bulletin 875C. Supelco Capillary GC Columns

Bulletin 875C. Supelco Capillary GC Columns C Supelco Capillary GC Columns Chemical structures, polarities, operating temperature ranges, and chemical compatibilities of Supelco generalpurpose capillary GC columns and columns for specific clinical,

More information

Introducing New Functionalities in Liquid Stationary Phases in GC Columns for Confirming Organic Volatile Impurity Testing in Pharmaceutical Products.

Introducing New Functionalities in Liquid Stationary Phases in GC Columns for Confirming Organic Volatile Impurity Testing in Pharmaceutical Products. Introducing New Functionalities in Liquid Stationary Phases in GC Columns for Confirming Organic Volatile Impurity Testing in Pharmaceutical Products. CHRISTOPHER M. ENGLISH, CHRISTOPHER S. COX, FRANK

More information

GC Resolution Do You See What I See?

GC Resolution Do You See What I See? GC Resolution Do You See What I See? Column Dimensions and Carrier Gas Optimization Deans Switch Page 1 Variables for Maximizing Resolution Optimized Stationary Phase Longer Column Length Decrease Internal

More information

Guide to GC Column Selection and Optimizing Separations

Guide to GC Column Selection and Optimizing Separations Guide to GC Column Selection and Optimizing Separations WHICH COLUMN DO I NEED? Learn how to choose the right column the first time. Optimize separations for the best balance of resolution and speed. Troubleshoot

More information

Supelco Ionic Liquid GC Columns Introduction to the Technology

Supelco Ionic Liquid GC Columns Introduction to the Technology Supelco Ionic Liquid GC Columns Introduction to the Technology Updated: -Jan-203 Agenda Overview GC Column Polarity Scale Temperature Effects on Selectivity Column Selectivity: QC Test Mix (0.2 mm I.D.

More information

CHEM340 Tutorial 4: Chromatography

CHEM340 Tutorial 4: Chromatography CHEM340 Tutorial 4: Chromatography 1. The data in the table below was obtained from a chromatogram obtained with a 10 cm liquid chromatography column. Under the conditions used, the compound uracil is

More information

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols. An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols. Jaap de Zeeuw, Ron Stricek and Gary Stidsen Restek Corp Bellefonte, USA To analyze basic compounds at

More information

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software High Efficiency GC Columns Page 1 Variables for Shortening Run Times Stationary Phase Shorten Column Length

More information

Product Brief. - Hydrocarbons alkanes, alkenes, alkynes, dienes including natural gas, refinery gas, liquified petroleum gas

Product Brief. - Hydrocarbons alkanes, alkenes, alkynes, dienes including natural gas, refinery gas, liquified petroleum gas Agilent Porous Polymer PLOT Columns: New Products, Expanded Uses, Prices Cut in Half! Product Brief Need improved resolution of small volatile compounds? Didn't try a PLOT column due to high price, short

More information

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software GC Columns and Consumables Mark Sinnott Application Engineer January 8 th, 2008 Page 1 Questions to Ask

More information

Improved Peak Shape Performance and Consistency for Analysis of Challenging Polar Compounds

Improved Peak Shape Performance and Consistency for Analysis of Challenging Polar Compounds Improved Peak Shape Performance and Consistency for Analysis of Challenging Polar Compounds Laura Provoost GC Columns Product Manager Agilent CrossLab Group Challenges when analyzing active polar compounds

More information

Unique Selectivity: The Power of Ionic Liquid GC Columns

Unique Selectivity: The Power of Ionic Liquid GC Columns Unique Selectivity: The Power of Ionic Liquid GC Columns Leonard M. Sidisky, Jamie L. Desorcie, Gustavo Serrano Izaguirre, Daniel L. Shollenberger; Greg A. Baney, Katherine K. Stenerson, and Michael D.

More information

Low Bleed Stationary Phases for Gas Chromatography

Low Bleed Stationary Phases for Gas Chromatography Low Bleed Stationary Phases for Gas Chromatography Slide 4 Advantages of Low Bleed Phase Lower bleed compared to standard phases Better signal to noise (sensitivity) Higher upper temperature - shorter

More information

Ultra-Inert chemistry for Trace Level Analysis

Ultra-Inert chemistry for Trace Level Analysis Ultra-Inert chemistry for Trace Level Analysis Cikui Liang, Ph.D. Challenges and Needs of Today s Laboratories Challenges Qualification/quantification of trace samples Keep instrument up and running Needs

More information

New ZB-5HT Inferno The World s Highest Temperature Non-Metal GC Column

New ZB-5HT Inferno The World s Highest Temperature Non-Metal GC Column New ZB-5HT Inferno The World s Highest Temperature Non-Metal GC Column The World's First Non-metal 5% Phenyl Phase GC Column Rated to 430 C * Specially processed for thermal stability up to 430 C A true

More information

Principles of Instrumental Analysis

Principles of Instrumental Analysis Principles of Instrumental Analysis Chapter 27 Gas Chromatography Gas Chromatography (GC): vaporized analytes (solutes) are partitioned between a mobile gaseous phase and a liquid or a solid stationary

More information

Understanding Gas Chromatography

Understanding Gas Chromatography Understanding Gas Chromatography What is Really Going on Inside the Box? Simon Jones GC Applications Engineer Page 1 Group/Presentation Title Month ##, 200X ?? K? Page 2 Typical GC System Gas supply Injector

More information

Column Selection. there is more to life than a boiling point column. Jaap de Zeeuw Restek Corporation, The Netherlands. Copyrights: Restek Corporation

Column Selection. there is more to life than a boiling point column. Jaap de Zeeuw Restek Corporation, The Netherlands. Copyrights: Restek Corporation Column Selection there is more to life than a boiling point column Jaap de Zeeuw Restek Corporation, The Netherlands Stationary Phase Selectivity Boiling Point versus Solubility Retention of a compound

More information

Speakers. Moderator. John V Hinshaw GC Dept. Dean CHROMacademy. Tony Taylor Technical Director CHROMacademy. Dave Walsh Editor In Chief LCGC Magazine

Speakers. Moderator. John V Hinshaw GC Dept. Dean CHROMacademy. Tony Taylor Technical Director CHROMacademy. Dave Walsh Editor In Chief LCGC Magazine Webcast Notes Type your questions in the Submit Question box, located below the slide window You can enlarge the slide window at any time by clicking on the Enlarge Slides button, located below the presentation

More information

Introduction to Gas Chromatography

Introduction to Gas Chromatography Introduction to Gas Chromatography 31-1 Objectives To know what is chromatography To understand the mechanism of compound separation To know the basic of gas chromatography system 31-2 Chromatography Definition

More information

METHOD 5000 SAMPLE PREPARATION FOR VOLATILE ORGANIC COMPOUNDS

METHOD 5000 SAMPLE PREPARATION FOR VOLATILE ORGANIC COMPOUNDS METHOD 5000 SAMPLE PREPARATION FOR VOLATILE ORGANIC COMPOUNDS 1.0 SCOPE AND APPLICATION 1.1 Method 5000 provides general guidance on the selection of sample preparation methods (purge-and-trap, extraction,

More information

Trajan SGE GC Columns

Trajan SGE GC Columns Trajan Scientific and Medical Trajan SGE GC Columns Trajan Scientific and Medical Our focus is on developing and commercializing technologies that enable analytical systems to be more selective, sensitive

More information

6-24 hours e. Coliform, Fecal and Total W, DW P,G Cool, 4 C, 0.008% Na 2 S 2 O 3. Fecal Streptococci W P,G Cool, 4 C, 0.

6-24 hours e. Coliform, Fecal and Total W, DW P,G Cool, 4 C, 0.008% Na 2 S 2 O 3. Fecal Streptococci W P,G Cool, 4 C, 0. Coliform, Colilert, P, Bottle or Bag Cool, 4 C, 0.008% Na 2 S 2 O 3 d Coliform, Fecal and Total, P,G Cool, 4 C, 0.008% Na 2 S 2 O 3 d Fecal Streptococci P,G Cool, 4 C, 0.008% Na 2 S 2 O 3 d INORGANIC TESTS

More information

Contents. Basic principles of capillary GC... 2

Contents. Basic principles of capillary GC... 2 Contents Gas Chromatography Introduction Basic principles of capillary GC... phases for GC Summary.... Phase selection by column parameters Primary selection features Phase polarity... 8 Film thickness....

More information

DiatoSorb-W Diatomaceous Earth: Great Chromatography Millions of Years in the Making

DiatoSorb-W Diatomaceous Earth: Great Chromatography Millions of Years in the Making Restek GC DiatoSorb-W Diatomaceous Earth: Great Chromatography Millions of Years in the Making Officially listed USP SA and SNS support material. Ideal for USP and ASTM methods that use white diatomaceous

More information

Ch24. Gas Chromatography (GC)

Ch24. Gas Chromatography (GC) Ch24. Gas Chromatography (GC) 24.1 What did they eat in the year 1000? From 13 C content of cholesterol in ancient bone 13 C : 1.1%, 12 C: 98.9% 13 C/ 12 C ratio types of plants Bones of 50 people in Barton-on-Humber

More information

SPE Introduction. general chromatography. solid phase extraction. How to Choose an SPE Product. Solid-Phase Processing Methods

SPE Introduction. general chromatography. solid phase extraction. How to Choose an SPE Product. Solid-Phase Processing Methods How to Choose an SPE Product 1. Characterize the Sample Factors such as the analyte s polarity relative to the matrix, the presence of charged functional groups, solubility, molecular weight, etc., determine

More information

US EPA Method with the Tekmar Lumin P&T Concentrator, AQUATek LVA and Agilent 7890B GC/5977A MS

US EPA Method with the Tekmar Lumin P&T Concentrator, AQUATek LVA and Agilent 7890B GC/5977A MS APPLICATION NOTE: TECHNOLOGY: INDUSTRY: AN1806 P+T VOC ENV US EPA Method 524.2 with the Tekmar Lumin P&T Concentrator, AQUATek LVA and Agilent 7890B GC/5977A MS Amy Nutter, Applications Chemist; Teledyne

More information

Water Injections in GC - Does Water Cause Bleed?

Water Injections in GC - Does Water Cause Bleed? Water Injections in GC - Does Water Cause Bleed? Eberhardt Kuhn Applications Chemist April 4, 2001 Practical Advice and Useful Tips for the Analysis of Semivolatile Organics by GC and GC/MS 11:00 a.m.

More information

GAS CHROMATOGRAPHY (GC)

GAS CHROMATOGRAPHY (GC) GAS CHROMATOGRAPHY (GC) Pre-Lab Questions Questions are to be answered before the beginning of the laboratory. The answers are due at the beginning of each experiment (the questions are for credit and

More information

Get Selective. By Jaap de Zeeuw

Get Selective. By Jaap de Zeeuw 34 Get Selective Modern narrow bore columns have made chromatographers lazy when it comes to stationary phase selection. Here s how getting back to basics in gas chromatography by using selectivity can

More information

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY Page 1 of 13 CIPAC/4105/R GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY Prepared for CIPAC by Dr M J Tandy*, P M Clarke and B White (UK) The rapid

More information

environmental Rtx -CLPesticides and Rtx -CLPesticides2 Columns: The Ideal Confirmational Pair for Analyzing Polychlorinated Biphenyls (PCBs)

environmental Rtx -CLPesticides and Rtx -CLPesticides2 Columns: The Ideal Confirmational Pair for Analyzing Polychlorinated Biphenyls (PCBs) environmental #59120 Applications note Rtx -CLPesticides and Rtx -CLPesticides2 Columns: The Ideal Confirmational Pair for Analyzing Polychlorinated Biphenyls (PCBs) Polychlorinated biphenyls (PCBs) are

More information

Class III Wastewater Laboratory Analyst Examination Study Guide 2008

Class III Wastewater Laboratory Analyst Examination Study Guide 2008 Class III Wastewater Laboratory Analyst Examination Study Guide 2008 Specific laboratory analyses included on Class III Exam: All Information and tests from Class I and Class II Plus the following - Biological

More information

Experience the Zebron Difference

Experience the Zebron Difference Experience the Zebron Difference Premier GC Column Selection Guide www.phenomenex.com/gc Introducing the Zebron Experience Proven Performance Zebron GC columns are engineered by expert Phenomenex GC scientists

More information

Chemistry Instrumental Analysis Lecture 28. Chem 4631

Chemistry Instrumental Analysis Lecture 28. Chem 4631 Chemistry 4631 Instrumental Analysis Lecture 28 Two types in general use: -packed (stationary phase) -open tubular or capillary determine selectivity and efficiency of the sample. Column Materials Column

More information

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1 Application Note US EPA Method 524.2 with the Teledyne Tekmar Lumin P&T Concentrator and Agilent 7890B GC / 5977A MS Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1 Abstract US EPA Method

More information

Biochemistry. Biochemical Techniques. 12 Gas Liquid Chromatography

Biochemistry. Biochemical Techniques. 12 Gas Liquid Chromatography Description of Module Subject Name Paper Name 12 Module Name/Title 12 Gas - liquid Chromatography 1. Objectives 1.1 To understand principle of Gas Liquid Chromatography 1.2 To explain the different components

More information

A New Web-Based Application for Modeling Gas Chromatographic Separations

A New Web-Based Application for Modeling Gas Chromatographic Separations A New Web-Based Application for Modeling Gas Chromatographic Separations Jaap de Zeeuw**, Rebecca Stevens*, Amanda Rigdon, Linx Waclaski*and Dan Li* *Restek Corporation, Bellefonte, PA, USA **Restek Corporation,

More information

Evaluating CLP and EPA Methods for Pesticides in Water Using Agilent J&W DB-CLP1/DB-CLP2 GC Columns

Evaluating CLP and EPA Methods for Pesticides in Water Using Agilent J&W DB-CLP1/DB-CLP2 GC Columns Evaluating CLP and EPA Methods for Pesticides in Water Using Agilent J&W DB-CLP/DB-CLP GC Columns Application Note Environmental Authors Doris Smith and Ken Lynam Agilent Technologies, Inc. Abstract The

More information

1. Carrier gas supply. - Flow rate measurement

1. Carrier gas supply. - Flow rate measurement Chapter 27 Gas chromatography Gas Chromatography - The components of a vaporized sample are separated as a consequence of being partitioned between a mobile gaseous phase and a liquid or a solid stationary

More information

Validation of USEPA Method Using a Stratum PTC and the New AQUATek 100 Autosampler

Validation of USEPA Method Using a Stratum PTC and the New AQUATek 100 Autosampler Validation of USEPA Method 524.2 Using a Stratum PTC and the New AQUATek 100 Autosampler Application Note Abstract Automation is the key to increasing laboratory productivity and minimizing costs. It is

More information

Hypersil BDS Columns TG 01-05

Hypersil BDS Columns TG 01-05 TG 0-0 Hypersil BDS Columns Introduction Hypersil BDS columns have gained a reputation over the years as one of the most robust, reproducible and reliable HPLC column brands available. This Technical Guide

More information

40 % OFF. Upgrade to Zebron GC Columns. Equivalent Selectivity. Better Service. ZB-1ms ZB-5 ZB-624. ZB-5ms ZB-WAX ZB-1.

40 % OFF. Upgrade to Zebron GC Columns. Equivalent Selectivity. Better Service. ZB-1ms ZB-5 ZB-624. ZB-5ms ZB-WAX ZB-1. Upgrade to Zebron GC Columns Equivalent Selectivity. Better Service. ZB-ms ZB-5 ZB-64 ZB- 40 % OFF Zebron GC columns ZB-WAX ZB-5ms * Expires: October 30, 009 Please Mention Offer Code: ZBE009 * Offer applies

More information

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application Analysis of Trace (mg/kg) Thiophene in Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application Petrochemical Authors James D. McCurry and Bruce D. Quimby Agilent Technologies

More information

2401 Gas (liquid) Chromatography

2401 Gas (liquid) Chromatography 2401 Gas (liquid) Chromatography Chromatography Scheme Gas chromatography - specifically gas-liquid chromatography - involves a sample being vaporized and injected onto the head of the chromatographic

More information

DiatoSorb-W Diatomaceous Earth: Great Chromatography Millions of Years in the Making

DiatoSorb-W Diatomaceous Earth: Great Chromatography Millions of Years in the Making DiatoSorb-W Diatomaceous Earth: Great Chromatography Millions of Years in the Making Officially listed USP SA and SNS support material Ideal for many USP and ASTM packed column methods Consistent quality

More information

Introduction to Capillary GC

Introduction to Capillary GC ?? Kβ? Page 1 Typical GC System Gas supply Injector Detector Data handling GAS Column Oven Page 2 CARRIER GAS Carries the solutes down the column Selection and velocity influences efficiency and retention

More information

Solid Phase Micro Extraction of Flavor Compounds in Beer

Solid Phase Micro Extraction of Flavor Compounds in Beer Solid Phase Micro Extraction of Flavor s in Beer ANNE JUREK USEPA 524.2 Method Validation Using the Evolution Purge and Trap Concentrator and the Centurion WS Autosampler Application Note Environmental

More information

C146-E209. Headspace Samplers. HS-20 Series

C146-E209. Headspace Samplers. HS-20 Series C146-E209 Headspace Samplers HS-20 Series HS-20 Series of Headspace Samplers A Revolutionary System Aimed at Performance and Ease of Use The HS-20 Series is the optimal solution for volatile component

More information

Secrets of GC Column Dimensions

Secrets of GC Column Dimensions Secrets of GC Column Dimensions GC Columns and Consumables Simon Jones Application Engineer May 20, 2008 Slide 1 Secrets of GC Column Dimensions Do I have the right column phase? Resolution Equation Changes

More information

6.1 Revision The following questions cover the important concepts that you should have understood in the first year introduction to chromatography.

6.1 Revision The following questions cover the important concepts that you should have understood in the first year introduction to chromatography. 6 Gas Chromatography 6.1 Revision The following questions cover the important concepts that you should have understood in the first year introduction to chromatography. 1. How does a gas chromatograph

More information

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System Application Note Residual Solvent Analysis of USP Method Residual Solvents on the Agilent 889 GC System Author Lukas Wieder, Jie Pan, and Rebecca Veeneman Agilent Technologies, Inc. 8 Centerville Road

More information

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph.

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph. Orosil OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph. Excellent organic base selectivity with very low asymmetry values Compatible

More information

A New Web-Based Application for Modeling Gas Chromatographic Separations. Dr. Hansjoerg Majer Restek Corporation Market Development Manager Europe

A New Web-Based Application for Modeling Gas Chromatographic Separations. Dr. Hansjoerg Majer Restek Corporation Market Development Manager Europe A New Web-Based Application for Modeling Gas Chromatographic Separations Dr. Hansjoerg Majer Restek Corporation Market Development Manager Europe The Method Development Process in GC $ SUCCESS! Developing

More information

Chlorinated Compounds in Hydrocarbon Streams Using a Halogen Specific Detector (XSD)

Chlorinated Compounds in Hydrocarbon Streams Using a Halogen Specific Detector (XSD) Introduction There has been an increase in concern for the detection and removal of organic chloride species from crude aromatic, naphtha, and other hydrocarbon streams. One process called catalytic reforming

More information

Chapter 27: Gas Chromatography. Principles Instrumentation Detectors Columns and Stationary Phases Applications

Chapter 27: Gas Chromatography. Principles Instrumentation Detectors Columns and Stationary Phases Applications Chapter 27: Gas Chromatography Principles Instrumentation Detectors Columns and Stationary Phases Applications GC-MS Schematic Interface less critical for capillary columns Several types of Mass Specs

More information

Analysis of Volatile Organic Compounds Using USEPA Method 8260 and the 4760 Purge and Trap and the 4100 Autosampler

Analysis of Volatile Organic Compounds Using USEPA Method 8260 and the 4760 Purge and Trap and the 4100 Autosampler Analysis of Volatile Organic Compounds Using USEPA Method 8260 and the 4760 Purge and Trap and the Introduction Although analysis of VOCs by purge and trap is considered a mature technique, advances in

More information

Roger Bardsley, Applications Chemist; Teledyne Tekmar P a g e 1

Roger Bardsley, Applications Chemist; Teledyne Tekmar P a g e 1 Application Note US EPA Method 524.4 with the Tekmar Lumin P & T Concentrator and Thermo Scientific TRACE 1310 GC and ISQ LT MS System Roger Bardsley, Applications Chemist; Teledyne Tekmar P a g e 1 Abstract

More information

Volatile organic compounds (VOCs):

Volatile organic compounds (VOCs): Volatile organic compounds (VOCs): Organic chemicals with a high vapour pressure at room temperature. High vapour pressure results from a low boiling point. The World Health Organization (WHO) defined

More information

Analysis of Volatile Organic Compounds in Soil Samples by EPA Method 8260 with The Stratum PTC and SOLATek 72 Multi-Matrix Autosampler

Analysis of Volatile Organic Compounds in Soil Samples by EPA Method 8260 with The Stratum PTC and SOLATek 72 Multi-Matrix Autosampler Analysis of Volatile Organic Compounds in Soil Samples by EPA Method 8260 with The Stratum PTC and SOLATek 72 Multi-Matrix Autosampler Application Note By: Teri Dattilio Introduction Purge and Trap concentration

More information

CUSTOM DEDICATED COLUMNS. '"' High lbmpsraturs columns. OIVl~I~ "

CUSTOM DEDICATED COLUMNS. '' High lbmpsraturs columns. OIVl~I~ improve your GC analysis Gc-MS columns CUSTOM DEDICATED COLUMNS d8x X~b chiral columns 20 rrrr7~~b _;;. ~C)ILJr, lr1e3 TM G products 2014 FAST-GC e s since 1980 Mega '"'---- - - -- High lbmpsraturs columns

More information

Using Hydrogen as An Alternative Carrier Gas for US EPA 8260

Using Hydrogen as An Alternative Carrier Gas for US EPA 8260 Using Hydrogen as An Alternative Carrier Gas for US EPA 8260 Application Note Abstract Due to regional shortages and increasing costs of helium, the preferred carrier gas in gas chromatography, alternative

More information

APPLICATION NOTE. A Capillary Approach to ASTM D3606: Test Method for Determination of Benzene and Toluene in Finished Motor and Aviation Gasoline

APPLICATION NOTE. A Capillary Approach to ASTM D3606: Test Method for Determination of Benzene and Toluene in Finished Motor and Aviation Gasoline A Capillary Approach to ASTM D3606: Test Method for Determination of Benzene and Toluene in Finished Motor and Aviation Gasoline Fast : Cycles in

More information

METHOD 8111 HALOETHERS BY GAS CHROMATOGRAPHY

METHOD 8111 HALOETHERS BY GAS CHROMATOGRAPHY 1.0 SCOPE AND APPLICATION METHOD 8111 HALOETHERS BY GAS CHROMATOGRAPHY 1.1 Method 8111 is a gas chromatographic (GC) method used to determine the concentration of haloethers. It describes wide-bore open-tubular,

More information

Validation of Environmental Water Methods on One System: Considerations for Sample Volume, Purge Parameters and Quality Control Parameters

Validation of Environmental Water Methods on One System: Considerations for Sample Volume, Purge Parameters and Quality Control Parameters Validation of Environmental Water Methods on One System: Considerations for Sample Volume, Purge Parameters and Quality Control Parameters Application Note Abstract Water quality laboratories across the

More information

CHAPTER 6 GAS CHROMATOGRAPHY

CHAPTER 6 GAS CHROMATOGRAPHY CHAPTER 6 GAS CHROMATOGRAPHY Expected Outcomes Explain the principles of gas chromatography Able to state the function of each components of GC instrumentation Able to state the applications of GC 6.1

More information

Jaap de Zeeuw Varian, Inc.. Middelburg, The Netherlands

Jaap de Zeeuw Varian, Inc.. Middelburg, The Netherlands "Innovations in capillary gas chromatography for improving reproducibility, reliability and ease-of-use in the gas chromatographic separation of complex samples" Jaap de Zeeuw Varian, Inc.. Middelburg,

More information

10/27/10. Chapter 27. Injector typically 50 C hotter than oven

10/27/10. Chapter 27. Injector typically 50 C hotter than oven Sample and solvent are vaporized onto the head of a column Vaporized solvent and solute are carried through the column by an inert gas (mobile phase) The mobile phase does not interact with compounds of

More information

CEE 772: Instrumental Methods in Environmental Analysis

CEE 772: Instrumental Methods in Environmental Analysis Updated: 10 December 2014 Print version CEE 772: Instrumental Methods in Environmental Analysis Lecture #24 Special Applications: Chromatographic Retention Time and Environmental Properties (Skoog, nothing)

More information