Accurate, Reproducible Results for Environmental Methods with Zebron GC Columns

Size: px
Start display at page:

Download "Accurate, Reproducible Results for Environmental Methods with Zebron GC Columns"

Transcription

1 Accurate, Reproducible Results for Environmental Methods with Zebron GC Columns BUY NOW AND SAVE! Length Sale Price* meter $ meter $ meter $ 599 *Offer valid only for addressee, limit 5 columns per company. Terms and conditions apply. See back for details. Expires: Offer Code: May 30, 2014 ZEBV0514

2 Featured Environmental Applications Semi-Volatile Organic Compounds in Under 16 Minutes Separated from Solvent Full Separation min APP ID min 1,4-Dioxane-D8 and 1,4-Dioxane min N-Nitrosodimethylamine and Pyridine Column: Zebron ZB-SemiVolatiles Dimensions: 30 meter x 0.25 mm x 0.25 μm Part No.: 7HG-G Injection: Split 280 C, 1 μl Carrier Gas: 1.4 ml/min (constant flow) Oven Program: 40 C for 0.5 min to C/min to C/min to C/min for 2 min Detector: 340 C; amu Sample: Analytes are 25 ppm in Dichloromethane Liner: AG (Single Taper with Wool) Septum: AG (PhenoRed -400) Inlet Seal: AG (Easy Seals Inlet Base Seals) Good Peak Shape Valley Height = 9.9 % 8270D Requires 50 % Less Tailing See the full compound list at min 2,4-Dinitrophenol min Benzo[b]fluoranthene and Benzo[k]fluoranthene min Pentachlorophenol Dual Column Analysis of Organochlorine Pesticides MR-1 Two Elution Order Changes MR App ID App ID min min Column: Zebron ZB-MultiResidue -1 Dimensions: 30 meter x 0.32 mm x 0.50 μm Part No.: 7HM-G Injection: 250 C, 1 μl Carrier Gas: 3.4 ml/min (constant flow) Oven Program: 100 C for 0.5 min to C/min to C/min for 2 min Detector: 350 C Sample: Performed using a 5 m Z-Guard Column and a 'Y' splitter. Column: Zebron ZB-MultiResidue-2 Dimensions: 30 meter x 0.32 mm x 0.25 μm Part No.: 7HM-G Injection: 250 C, 1 μl Carrier Gas: 3.4 ml/min (constant flow) Oven Program: 100 C for 0.5 min to C/min to C/min for 2 min Detector: 350 C Sample: Performed using a 5 m Z-Guard Column and a 'Y' splitter. See the full compound list at

3 GC Column Selection for EPA Methods Drinking Water Waste Water Solid Waste Air Method # Description Primary Column Confirmation Column Trihalomethanes by GC/MS with Selected Ion Monitoring (SIM) ZB Volatile Halogenated Organics by Purge & Trap GC/PID/ELCD ZB Volatile Aromatics and Unsaturated Organics by Purge & Trap GC ZB ,2-Dibromoethane (EDB), 1,2-Dibromo-3-chloropropane (DBCP), and 1,2,3-Trichloropropane (123TCP) by GC ZB-1 ZB Organohalide Pesticides & Aroclors by GC/ECD ZB-MultiResidue -1 ZB-MultiResidue Nitrogen & Phosphorus Containing Pesticides by GC/NPD ZB-MultiResidue-1 ZB-MultiResidue Chlorinated Pesticides by GC/ECD ZB-MultiResidue-1 ZB-MultiResidue Ethylene Thiourea (ETU) by GC/NPD ZB-WAXPLUS ZB , 3, 7, 8-Tetrachlorodibenzo-p-dioxin by GC/HRMS ZB-5ms Chlorinated Acids by Liquid-Liquid Extraction, Derivatization and GC/ECD ZB-XLB ZB Nitrosamines by Solid Phase Extraction (SPE) and GC/MS/MS with Large Volume Injection ZB-5ms 522 1,4-Dioxane by Solid Phase Extraction (SPE) and GC/MS with Selected Ion Monitoring (SIM) ZB-SemiVolatiles 523 Triazine Pesticides and their Degradates by GC/MS ZB Purgeable Organic Compounds by GC/MS ZB Semi-volatile Organic Chemicals by Solid Phase Extraction (SPE) and GC/MS ZB-SemiVolatiles 526 Selected Semi-volatile Organic Compounds by Solid Phase Extraction (SPE) and GC/MS ZB-SemiVolatiles 527 Selected Pesticides and Flame Retardants by Solid Phase Extraction (SPE) and GC/MS ZB-5MSi 528 Phenols by Solid Phase Extraction (SPE) and GC/MS ZB-SemiVolatiles 529 Explosives and Related Compounds by Solid Phase Extraction (SPE) and GC/MS ZB-5MSi 548 Endothall by Aqueous Derivatization, Liquid-Solid Extraction, and GC/ECD ZB-SemiVolatiles ZB Chlorinated Solvents & Disinfection Byproducts by Liquid-Liquid Extraction and GC/ECD ZB Haloacetic Acids and Dalapon by Liquid-Liquid Extraction, Derivatization, and GC/ECD ZB-XLB ZB Carbonyl Compounds by Pentafluorobenzylhydroxylamine Derivatization and GC/ECD ZB-5ms ZB Purgeable Halocarbons by Purge & Trap GC ZB Purgeable Aromatics by Purge & Trap GC ZB Acrolein & Acrylonitrile Purge & Trap GC ZB Phenols by GC/ECD ZB-SemiVolatiles 606 Phthalate Esters by GC/ECD ZB-5MSi 607 Nitrosamines by GC/NPD ZB-SemiVolatiles 608 Organochlorine Pesticides and PCBs by GC/ECD ZB-MultiResidue Nitroaromatics & Isophorone by GC/FID and GC/ECD ZB-SemiVolatiles 610 Polynuclear Aromatic Hydrocarbons by GC/FID ZB-SemiVolatiles 611 Haloethers by GC/ECD ZB-5ms 612 Chlorinated Hydrocarbons by GC/ECD ZB-5ms 613 2,3,7,8-Tetrachlorodibenzo-p-dioxin by GC/MS ZB-5ms 615 Chlorinated Herbicides by GC/ECD ZB-XLB ZB Triazine Herbicides by GC/MS ZB Organophosphorus Pesticides by GC/MS ZB-MultiResidue Purgeable Volatiles by Purge & Trap GC/MS ZB Base/Neutral and Acids by GC/MS ZB-SemiVolatiles 1613 Tetra- through Octa-Chlorinated Dioxins and Furans by Isotope Dilution HRGC/HRMS ZB-5ms 1614 Polybrominated Diphenyl Esters (PBDEs) by HRGC/HRMS ZB-5HT 1618 Organohalide Pesticides, Organophosphorus Pesticides, and Phenoxy-Acid Herbicides by GC ZB-MultiResidue-1 ZB-MultiResidue Volatile Organic Compounds by Isotope Dilution GC/MS ZB Semi-volatile Organic Compounds by Isotope Dilution GC/MS ZB-SemiVolatiles 1653 Chlorinated Phenols by In-Situ Acetylation and GC/MS ZB-SemiVolatiles 1657 Organophosphorous Pesticides by GC/FPD ZB-MultiResidue-1 ZB-MultiResidue Phenoxy-Acid Herbicides by GC/ECD ZB-MultiResidue-1 ZB-MultiResidue Dazomet by GC/NPD ZB-MultiResidue-1 ZB-MultiResidue Pharmaceutical Volatile Organic Compounds by Purge & Trap GC or Isotope Dilution GC/MS ZB-SemiVolatiles (Direct Injection) ZB-624 (Purge & Trap) 1668 Polychlorinated Biphenyl (PCB) Congeners by HRGC/HRMS ZB-MultiResidue-1 ZB Pharmaceutical Manufacturing Volatile Organic Compounds by GC/FID ZB White Phosphorus (P4) by Solvent Extraction and GC/NPD ZB B Halogenated Volatile Organics by GC/ELCD ZB C Nonhalogenated Organics by GC ZB-5HT 8020A Aromatic Volatile Organics by GC/PID ZB-WAX 8021B Aromatic and Halogenated Volatiles by GC/PID or GC/ELCD ZB-624 ZB-1 (thick phase) 8030A Acrolein and Acrylonitrile by GC/FID ZB A Acrylamide by GC/ECD ZB-5HT 8041 Phenols by GC/ECD or GC/FID ZB-SemiVolatiles 8061A Phthalate Esters by GC/ECD ZB-5ms ZB B Organochlorine Pesticides by GC/ECD ZB-MultiResidue-1 ZB-MultiResidue A Polychlorinated Biphenyls (PCBs) by GC/ECD ZB-MultiResidue-1 ZB-MultiResidue Nitroaromatics and Cyclic Ketones by GC/ECD or GC/NPD ZB-5ms ZB Explosives by GC/ECD ZB Polynuclear Aromatic Hydrocarbons by GC/FID ZB-SemiVolatiles 8121 Chlorinated Hydrocarbons by GC/ECD ZB-MultiResidue-1 ZB-MultiResidue Aniline and Selected Derivatives by GC/NPD ZB-SemiVolatiles ZB B Organophosphorus Pesticides by GC/FPD or GC/NPD ZB-MultiResidue-1 ZB-MultiResidue A Chlorinated Herbicides by GC/ECD ZB-XLB ZB B Volatile Organic Compounds by GC/MS ZB D Semi-volatile Organic Compounds by GC/MS ZB-SemiVolatiles 8272 Polynuclear Aromatic Hydrocarbons (PAHs ) by SPME and GC/MS with Selected Ion Monitoring (SIM) ZB-SemiVolatiles 8280B Polychlorinated Dibenzo-P-Dioxins (PCDDs) and Polychlorinated Dibenzofurans (PCDFs) By HRGC/LRMS ZB-5ms 8290A Polychlorinated Dibenzo-P-Dioxins (PCDDs) and Polychlorinated Dibenzofurans (PCDFs) By HRGC/HRMS ZB-5ms 8410 Semi-Volatile Organic Compounds by GC/FT-IR ZB-SemiVolatiles 8430 Bis(2-chloroethyl) Ether and Hydrolysis Products by Direct Aqueous Injection GC/FT-IR ZB-WAXPLUS TO-1 Volatile Organic Compounds by Thermal Adsorption and GC/MS ZB-1 TO-2 Volatile Organic Compounds by Carbon Molecular Sieve Adsorption and GC/MS ZB-1 TO-3 Volatile Organic Compounds by Cryogenic Preconcentration Techniques and GC/FID/ECD ZB-1 TO-4A Pesticides and Polychlorinated Biphenyls (PCBs) by High Volume Polyurethane Foam (PUF) Sampling and GC ZB-MultiResidue-1 TO-7 N-Nitrosodimethylamine by GC/MS ZB-WAXPLUS TO-9A Polychlorinated, Polybrominated, and Brominated/Chlorinated Dibenzo-p-Dioxins and Dibenzofurans by HRGC/HRMS ZB-5ms TO-10A Pesticides and Polychlorinated Biphenyls (PCBs) by Low Volume Polyurethane Foam (PUF) Sampling and GC ZB-MultiResidue-1 TO-13A Polycyclic Aromatic Hydrocarbons (PAHs) by GC/MS ZB-5ms TO-14A Volatile Organic Compounds by Specially Prepared Canisters and GC ZB-1 TO-15 Volatile Organic Compounds by Specially Prepared Canisters and GC/MS ZB-1 Find Environmental Applications Online! Check out our application search tool for more environmental chromatograms at

4 Ordering Information Step 1: Use the selection tables to locate the Zebron columns for your application or select Zebron alternatives to your current GC columns. Step 2: Stock Up and Save! Below is a list of the most popular dimensions. Contact your GC Specialist or visit for more. NEW! ZB-SemiVolatiles ZB-1 ZB-1ms ZB-1HT Inferno ZB-5 ZB-5ms ZB-5MSi ZB-5HT Inferno $ 199 $ 399 $ 599 ID (mm) df (μm) 10 meter 15 meter 30 meter 60 meter HG-G KG-G HG-G EG-G HG-G KG-G EG-G HG-G KG-G HG-G EG-G HG-G KG-G KM-G EM-G HM-G KM-G HM-G EM-G HM-G KM-G KM-G HM-G EK-G EK-G HK-G EK-G HK-G KK-G CK-G EK-G HK-G EK-G HK-G CB-G CD-G HG-G EG-G HG-G KG-G HG-G HG-G KG-G EM-G HM-G HM-G KM-G HK-G EK-G HK-G EG-G HG-G HG-G EM-G HM-G EM-G HM-G EG-G HG-G KG-G EG-G HG-G KG-G EG-G HG-G KG-G EG-G HG-G KG-G EM-G HM-G EM-G HM-G KM-G HM-G EM-G HM-G KM-G EK-G HK-G EK-G HK-G KK-G EK-G HK-G HK-G CB-G CD-G EG-G HG-G KG-G HG-G HG-G HM-G KM-G HM-G HM-G CD-G EG-G HG-G KG-G HG-G HG-G HM-G HM-G EK-G HK-G EG-G HG-G EG-G HG-G EM-G HM-G EM-G HM-G USA Tel: Canada Tel: Puerto Rico Tel: Phenomenex Fax: info@phenomenex.com Web:

5 Ordering Information ZB-35 ZB-35HT Inferno ZB-50 ZB-624 ZB-1701 ZB-WAX ZB-WAXPLUS ZB-MultiResidue -1 ZB-MultiResidue-2 ZB-XLB ZB-XLB-HT Inferno $ 199 $ 399 $ 599 ID (mm) df (μm) 10 meter 15 meter 30 meter 60 meter EG-G HG-G KG-G EG-G HG-G HM-G KM-G HK-G EK-G HK-G EG-G HG-G HM-G EG-G EG-G HG-G KG-G HG-G KG-G EM-G HM-G EM-G HM-G EK-G HK-G HG-G KG-G HM-G KM-G HK-G KK-G EG-G HG-G KG-G HG-G EM-G HM-G KM-G EM-G HM-G HK-G CB-G HG-G KG-G EG-G HG-G KG-G HG-G HG-G HM-G EM-G HM-G EM-G HM-G KM-G HK-G EK-G HK-G CB-G HG-G KG-G HM-G HM-G KM-G HK-G KK-G HG-G HM-G HK-G HG-G HM-G HK-G CD-G HG-G KG-G HG-G HM-G HM-G EG-G HG-G EG-G HG-G KG-G EM-G HM-G Environmental Customer Spotlight: I have found the Phenomenex ZB-SemiVolatiles columns to be superior in quality and durability than any other columns we have previously used. The columns not only last longer, but the reproducibility of column is extraordinary. The column holds calibrations particularly well, even after multiple injections of samples with far less than desirable matrices. All of this equates to less downtime and maintenance and more productivity for TestAmerica. Ryan McKernan, GC/MS Semi-Volatile Analyst, TestAmerica Laboratories, Inc. Buffalo. USA Tel: Canada Tel: Puerto Rico Tel: Phenomenex Fax: info@phenomenex.com Web:

6 GC Column Selection by Application Description Zebron Phases Aroclors ZB-XLB Diesel Range Organics (DROs) ZB-1HT Inferno, ZB-5HT Inferno Dioxins ZB-5ms Gasoline Range Organics (GROs) ZB-1 Glycols ZB-WAXPLUS Explosives ZB-50 Haloacetic Acids ZB-XLB Haloethers ZB-5 Herbicides Chlorinated Herbicides ZB-MultiResidue -1 and -2 Triazine Herbicides ZB-50 Hydrocarbons Chlorinated Hydrocarbons ZB-5ms Polynuclear Aromatic Hydrocarbons (PAHs) ZB-SemiVolatiles Total Petroleum Hydrocarbons (TPH) ZB-5ms Nitrosamines ZB-WAX Nitroaromatics ZB-5 Pesticides Multi-Pesticide Screening ZB-MultiResidue-1 and -2 Chlorinated Pesticides ZB-MultiResidue-1 and -2 Organophosphorous Pesticides ZB-5MSi Nitrogen and Phosphorous Pesticides Phenols Phthalates Polybrominated Diphenyl Ethers (PBDEs) Polychlorinated Biphenyls (PCBs) Semi-Volatile Organics (SVOCs) Volatile Organics (VOCs) ZB-MultiResidue-1 ZB-SemiVolatiles ZB-5ms ZB-5HT Inferno ZB-MultiResidue-1 ZB-SemiVolatiles ZB-624 If Zebron columns do not provide you with equivalent or better separations as compared to any other GC column of the same phase and comparable dimensions, send in your comparative data within 45 days and keep the column for FREE!

7 Get the Environmental Edge with online resources designed for environmental analysts Environmental 1000 s of Applications Environmental Edge Newsletter EPA Selection Poster Technical Notes Knowledgable GC Specialists

8 BUY NOW AND SAVE! Length Sale Price* PRSRT STD U.S. POSTAGE PAID TORRANCE, CA PERMIT NO meter $ meter $ meter $ 599 *Offer valid only for addressee, limit 5 columns per company. Terms and conditions apply. Terms and Conditions Offer applies only to first-time purchasers of Zebron GC columns, limit 5 columns per company. Offer excludes custom and guard columns. Offer applies only to Zebron columns listed in this brochure. Offer must be specified at time of order and may not be combined with any other discount or promotional item. Subject to Phenomenex Standard Terms and Conditions, which may be viewed at www. phenomenex.com/termsandconditions Trademarks EasySeals, Inferno, MultiResidue, PhenoRed, WAXPLUS, Zebron, and Z-Guard are trademarks of Phenomenex Phenomenex, Inc. All rights reserved. BR _us Australia t: f: auinfo@phenomenex.com Austria t: f: anfrage@phenomenex.com Belgium t: (French) t: (Dutch) f: +31 (0) beinfo@phenomenex.com Canada t: (800) f: (310) info@phenomenex.com Denmark t: f: nordicinfo@phenomenex.com Finland t: f: nordicinfo@phenomenex.com France t: f: franceinfo@phenomenex.com Germany t: f: anfrage@phenomenex.com India t: f: indiainfo@phenomenex.com Ireland t: f: eireinfo@phenomenex.com Italy t: f: italiainfo@phenomenex.com Luxembourg t: +31 (0) f: +31 (0) nlinfo@phenomenex.com Mexico t: f: tecnicomx@phenomenex.com The Netherlands t: f: nlinfo@phenomenex.com New Zealand t: f: nzinfo@phenomenex.com Norway t: f: nordicinfo@phenomenex.com Puerto Rico t: (800) 541-HPLC f: (310) info@phenomenex.com Sweden t: f: nordicinfo@phenomenex.com United Kingdom t: f: ukinfo@phenomenex.com United States t: (310) f: (310) info@phenomenex.com All other countries: Corporate Office USA t: (310) f: (310) info@phenomenex.com Phenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department at international@phenomenex.com 411 Madrid Avenue Torrance, CA USA

Fast, Accurate Environmental Testing

Fast, Accurate Environmental Testing GC Columns Fast, Accurate Environmental Testing Using Zebron GC Columns Featuring Pesticides Diesel Range Organics Semivolatiles Dioxane And more.. www.phenomenex.com/environmental Semi-Volatile Organic

More information

The BIG GC Special. Details, Playoff Specials, and Early Bird Discounts Inside! Expires: December 20, 2013 Mention Offer Code: ZBNF1213.

The BIG GC Special. Details, Playoff Specials, and Early Bird Discounts Inside! Expires: December 20, 2013 Mention Offer Code: ZBNF1213. The BIG GC Special Details, Playoff Specials, and Early Bird Discounts Inside! Exclusive Savings on Zebron GC Columns for any phase new to your company* Length 10-15 Meter 30 Meter 60 Meter Sale Price

More information

EPA Test Methods for GC

EPA Test Methods for GC EPA Test Methods for GC Method # Description 0016B Total Reduced Sulfur - (GC Analysis) 0018 VOC - GC 0311 HAPS in Paints & Coatings - Direct Injection GC 0312A Residual Styrene in SBR Latex by GC 0312B

More information

Take Your Food Testing to the Next Level

Take Your Food Testing to the Next Level GC Columns Take Your Food Testing to the Next Level Using Zebron GC Columns Featuring Pesticides FAMEs Essential Oils Flavors And more.. www.phenomenex.com/foodgc Pesticide Screening by GC-MS - 7 7 9,9

More information

Analysis. Priority LC GC. Zebron PAH Accurately quantitate EU and EPA PAHs in less than 28 minutes

Analysis. Priority LC GC. Zebron PAH Accurately quantitate EU and EPA PAHs in less than 28 minutes Priority Analysis LC GC Core-Shell Technology GC Columns Kinetex PAH Expanded resolution with chemical selectivity specifically for PAHs Increased throughput and sensitivity with core-shell technology

More information

APPLICATIONS TN Peptide Purification Method Development: Application for the Purification of Bivalirudin. Introduction

APPLICATIONS TN Peptide Purification Method Development: Application for the Purification of Bivalirudin. Introduction Peptide Purification Method Development: Application for the Purification of Bivalirudin Marc Jacob, Joshua Heng, and Tivadar Farkas Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 91 USA In this technical

More information

AGGREGATE ANALYSIS. Biologics Workflow. by Size Exclusion Chromatography

AGGREGATE ANALYSIS. Biologics Workflow. by Size Exclusion Chromatography Biologics Workflow AGGREGATE ANALYSIS by Size Exclusion Chromatography New biozen SEC columns provide: High efficiency on both HPLC and UHPLC Extreme inertness and robustness Finely tuned high and low

More information

New ZB-5HT Inferno The World s Highest Temperature Non-Metal GC Column

New ZB-5HT Inferno The World s Highest Temperature Non-Metal GC Column New ZB-5HT Inferno The World s Highest Temperature Non-Metal GC Column The World's First Non-metal 5% Phenyl Phase GC Column Rated to 430 C * Specially processed for thermal stability up to 430 C A true

More information

Fast and Accurate Analysis of PBDEs in a Single Run, Including

Fast and Accurate Analysis of PBDEs in a Single Run, Including Fast and Accurate Analysis of PBDEs in a Single Run, Including Kory Kelly, Adam Endeman, and Matthew Trass Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 90501 USA PO14700713_2 PO14400613_W_2 Abstract

More information

Fast and Accurate Analysis of PBDEs in a Single Run, Including BDE-209

Fast and Accurate Analysis of PBDEs in a Single Run, Including BDE-209 Fast and Accurate Analysis of PBDEs in a Single Run, Including Kory Kelly, Xianrong (Jenny) Wei, and Matthew Trass Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 90501 USA PO16570913_W_2 PO14400613_W_2

More information

Quick and Simple Cleanup for. Medicinal Chemistry. It s BIG.

Quick and Simple Cleanup for. Medicinal Chemistry. It s BIG. Quick and Simple Cleanup for Medicinal It s IG. Guaranteed Cleanup of Post Synthesis Reactions Strata -XL Giga s are designed to make Medicinal easy! With Strata Giga tubes I ve been able to purify a compound

More information

4. Place a 20 ml VOA vial in position 1 of the tray. 5. Place a 6 ml C18-E cartridge in position 1 of the carousel.

4. Place a 20 ml VOA vial in position 1 of the tray. 5. Place a 6 ml C18-E cartridge in position 1 of the carousel. Increase Throughput and Recoveries for EPA Method 508.1 with Automated Extraction using Strata C18-E SPE Cartridges and Zebron ZB-MultiResidue GC Columns Kali Tudela Phenomenex, Inc., 411 Madrid Ave.,

More information

Gemini-NX Performance paired with Axia Technology

Gemini-NX Performance paired with Axia Technology Si Si Si Si Si Si Si C Si Si Si Si Si Gemini-NX Performance paired with Axia Technology Gemini -NX Axia Packed Technology Improves Yield, Throughput, and Column Lifetime Ideal Purification Platform While

More information

METHOD 3600C CLEANUP

METHOD 3600C CLEANUP METHOD 3600C CLEANUP 1.0 SCOPE AND APPLICATION 1.1 Method 3600 provides general guidance on selection of cleanup methods that are appropriate for the target analytes of interest. Cleanup methods are applied

More information

METHOD 3600B CLEANUP

METHOD 3600B CLEANUP METHOD 3600B CLEANUP 1.0 SCOPE AND APPLICATION 1.1 Method 3600 provides general guidance on selection of cleanup methods that are appropriate for the target analytes of interest. Cleanup methods are applied

More information

Your Reversed Phase Method

Your Reversed Phase Method PLC Columns for Your Reversed Phase Method Balanced Non-Polar & Polar Selectivity Strong Non-Polar & Polar Selectivity Strong Polar & Aromatic Selectivity Unique Isomeric & alogenated Selectivity Robust

More information

APPLICATIONS TN Separation and Quantitation of Physiologic Cobalamins (Vitamin B 12

APPLICATIONS TN Separation and Quantitation of Physiologic Cobalamins (Vitamin B 12 APPLICATIONS Separation and Quantitation of Physiologic Cobalamins (Vitamin B 12 in Dietary Supplements by LC/MS/MS using Synergi Fusion-RP Column Xianrong (Jenny Wei Senior Scientist PhenoLogix applications

More information

Rtx -CLPesticides Columns Reduce Analysis Time; Reduce System Maintenance

Rtx -CLPesticides Columns Reduce Analysis Time; Reduce System Maintenance Columns Reduce Analysis Time; Reduce System Maintenance 0 YEARS Turning Visions into Reality www.restek.com 00-- --00 and Fused Silica Columns Detect and confirm 0 common organochlorine pesticides simultaneously.

More information

3 Ways To Choose. All GC 5 Phases Are Not The Same! ZB-5. ZB-5MSi. ZB-5HT Inferno. ZB-5ms ZB-5MSPLUS. ZB-SemiVolatiles.

3 Ways To Choose. All GC 5 Phases Are Not The Same! ZB-5. ZB-5MSi. ZB-5HT Inferno. ZB-5ms ZB-5MSPLUS. ZB-SemiVolatiles. 3 Ways To Choose All GC 5 Phases Are Not The Same! ZB-5 ZB-5M ZB-5HT Inferno ZB-5ms ZB-5MSPLUS ZB-SemiVolatiles www.phenomenex.com/5phase Choosing Your 5 Phase Is Easy Use the NEW GC Column Finder web

More information

environmental Rtx -CLPesticides and Rtx -CLPesticides2 Columns: The Ideal Confirmational Pair for Analyzing Polychlorinated Biphenyls (PCBs)

environmental Rtx -CLPesticides and Rtx -CLPesticides2 Columns: The Ideal Confirmational Pair for Analyzing Polychlorinated Biphenyls (PCBs) environmental #59120 Applications note Rtx -CLPesticides and Rtx -CLPesticides2 Columns: The Ideal Confirmational Pair for Analyzing Polychlorinated Biphenyls (PCBs) Polychlorinated biphenyls (PCBs) are

More information

D2245

D2245 GC Columns and Accessories Thermo Scientific Chromatography Columns and Consumables 2014-2015 GC Column Selection by ASTM Method Selected ASTM methods are listed below with the appropriate Thermo Scientific

More information

APPLICATIONS TN Lux Cellulose-2 or -4 Cellulose tris (3-chloro-4-methylphenylcarbamate) or (4-chloro-3-methylphenylcarbamate)

APPLICATIONS TN Lux Cellulose-2 or -4 Cellulose tris (3-chloro-4-methylphenylcarbamate) or (4-chloro-3-methylphenylcarbamate) T-1079 APPLICATI Method Development for Reversed Phase Chiral LC/M/M Analysis of tereoisomeric Pharmaceutical Compounds with Polysaccharide-based tationary Phases Philip J. Koerner, Kari Carlson, Liming

More information

Experience the Zebron Difference

Experience the Zebron Difference Experience the Zebron Difference Premier GC Column Selection Guide www.phenomenex.com/gc Introducing the Zebron Experience Proven Performance Zebron GC columns are engineered by expert Phenomenex GC scientists

More information

APPLICATIONS TN Detection of Environmental Contaminants Caused by the Oil Spill in the Gulf of Mexico by GC and HPLC

APPLICATIONS TN Detection of Environmental Contaminants Caused by the Oil Spill in the Gulf of Mexico by GC and HPLC Detection of Environmental Contaminants Caused by the Oil Spill in the Gulf of Mexico by GC and HPLC Sky Countryman, Ngoc Nguyen, Jeff Layne, Kory Kelly, and Zeshan Aqeel Phenomenex, Inc., 411 Madrid Ave.,

More information

Developing Large Volume Injection (LVI) in Split / Splitless Inlets. Philip J. Koerner Phenomenex Inc. NEMC 2014

Developing Large Volume Injection (LVI) in Split / Splitless Inlets. Philip J. Koerner Phenomenex Inc. NEMC 2014 Developing Large Volume Injection (LVI) in Split / Splitless Inlets Philip J. Koerner Phenomenex Inc. NEMC 2014 Goal To produce a method that provides the largest response of analytes that will produce

More information

APPLICATIONS TN HPLC Conditions. Lux Cellulose-1 Cellulose tris(3,5-dimethylphenylcarbamate)

APPLICATIONS TN HPLC Conditions. Lux Cellulose-1 Cellulose tris(3,5-dimethylphenylcarbamate) T-147 APPLICATIS Alternative Selectivity of Chiral Stationary Phases Based on Cellulose tris(3-chloro-4-methylphenylcarbamate) and Cellulose tris(3,5-dimethylphenylcarbamate) Liming Peng, Tivadar Farkas

More information

Evaluating CLP and EPA Methods for Pesticides in Water Using Agilent J&W DB-CLP1/DB-CLP2 GC Columns

Evaluating CLP and EPA Methods for Pesticides in Water Using Agilent J&W DB-CLP1/DB-CLP2 GC Columns Evaluating CLP and EPA Methods for Pesticides in Water Using Agilent J&W DB-CLP/DB-CLP GC Columns Application Note Environmental Authors Doris Smith and Ken Lynam Agilent Technologies, Inc. Abstract The

More information

U.S. EPA Method 8270 for multicomponent analyte determination

U.S. EPA Method 8270 for multicomponent analyte determination ENVIRONMENTAL application note U.S. EPA Method 8270 for multicomponent analyte determination Elaine A. LeMoine and Herman Hoberecht Introduction Multicomponent analytes are compounds that yield several

More information

A Direct 5 ms Column Performance Comparison for Active Semi-Volatile Analytes

A Direct 5 ms Column Performance Comparison for Active Semi-Volatile Analytes A Direct 5 ms Column Performance Comparison for Active Semi-Volatile Analytes Application Note Environmental Authors Ken Lynam and Doris Smith Agilent Technologies, Inc. 2850 Centerville Road Wilmington,

More information

APPLICATIONS TN Increased Capabilities for the Analysis of Hormones in Drinking and Waste Water Using Solid Phase Extraction (SPE) and LC/MS/MS

APPLICATIONS TN Increased Capabilities for the Analysis of Hormones in Drinking and Waste Water Using Solid Phase Extraction (SPE) and LC/MS/MS Increased Capabilities for the Analysis of Hormones in Drinking and Waste Water Using Solid Phase Extraction (SPE) and LC/MS/MS Xianrong (Jenny) Wei Senior Scientist Jenny is a Senior Scientist in Phenomenex

More information

ApplicationNOTE ULTRA TRACE ANALYSIS OF DIOXINS AND FURANS IN HUMAN ADIPOSE TISSUE USING SFE-LC EXTRACTION/CLEANUP AND THE WATERS AUTOSPEC ULTIMA NT

ApplicationNOTE ULTRA TRACE ANALYSIS OF DIOXINS AND FURANS IN HUMAN ADIPOSE TISSUE USING SFE-LC EXTRACTION/CLEANUP AND THE WATERS AUTOSPEC ULTIMA NT Introduction Legislative limits for dioxins and furans are ever decreasing 1, providing a greater challenge for the dioxin analyst. The extraction and clean-up processes used by the analyst can be imperative

More information

ApplicationNOTE A STUDY OF THE ANALYSIS OF POLYBROMINATED DIPHENYL ETHER FLAME RETARDANTS BY GC/MS/MS. Introduction. Materials and Methods

ApplicationNOTE A STUDY OF THE ANALYSIS OF POLYBROMINATED DIPHENYL ETHER FLAME RETARDANTS BY GC/MS/MS. Introduction. Materials and Methods Abstract The development of a GC/MS/MS method for the analysis of brominated flame retardants will be presented. Standard methods require the use of high resolution magnetic sector instrumentation, which

More information

Agilent J&W GC Column Selection Guide SPEED YOUR SELECTION WITH THIS ONE-STOP RESOURCE

Agilent J&W GC Column Selection Guide SPEED YOUR SELECTION WITH THIS ONE-STOP RESOURCE Agilent J&W GC Column Selection Guide SPEED YOUR SELECTION WITH THIS ONE-STOP RESOURCE Table of Contents The story behind Agilent J&W Advanced GC Columns... 1 Column Selection Principles... 3 Selecting

More information

Hans-Joachim Hubschmann. Handbook ofgc-ms. Fundamentals and Applications. Third Edition. Wl LEY-VCH. VerlagGmbH & Co. KG aa

Hans-Joachim Hubschmann. Handbook ofgc-ms. Fundamentals and Applications. Third Edition. Wl LEY-VCH. VerlagGmbH & Co. KG aa Hans-Joachim Hubschmann Handbook ofgc-ms Fundamentals and Applications Third Edition Wl LEY-VCH VerlagGmbH & Co. KG aa VII Foreword XIII Preface to the Third Edition XV 1 Introduction 1 1.1 The Historical

More information

GC Analysis of Polybrominated Flame Retardants Application

GC Analysis of Polybrominated Flame Retardants Application GC Analysis of Polybrominated Flame Retardants Application Environmental Authors Eberhardt Kuhn, Jason Ellis Agilent Technologies, Inc. 91 Blue Ravine Rd, Folsom, CA 9563 USA Steve Wilbur Agilent Technologies,

More information

METHOD 5000 SAMPLE PREPARATION FOR VOLATILE ORGANIC COMPOUNDS

METHOD 5000 SAMPLE PREPARATION FOR VOLATILE ORGANIC COMPOUNDS METHOD 5000 SAMPLE PREPARATION FOR VOLATILE ORGANIC COMPOUNDS 1.0 SCOPE AND APPLICATION 1.1 Method 5000 provides general guidance on the selection of sample preparation methods (purge-and-trap, extraction,

More information

GC COLUMN GUIDE. Powerful Gas Chromatography and Chromatography Data System Solutions

GC COLUMN GUIDE. Powerful Gas Chromatography and Chromatography Data System Solutions COLUMN GUE Powerful Gas Chromatography and Chromatography Data System Solutions Column Reference Guide Column Reference guide by phase SCION Column Phase Composition/Porous Layer Application SCION-1MS

More information

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil Che Jinshui, 1 Deng Guifeng, 1 Liang Lina, 1 and Aaron Kettle, 2 1 Thermo Fisher Scientific (China)

More information

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7B Triple Quadrupole GC/MS Application Note Authors Dale R. Walker and Fred Feyerherm Agilent Technologies, Inc.

More information

Using Magnetic Sector GC-HRMS in a Commercial Dioxin Lab

Using Magnetic Sector GC-HRMS in a Commercial Dioxin Lab An Executive Summary Using Magnetic Sector GC-HRMS in a Commercial Dioxin Lab David Hope Chief Executive Officer Pacific Rim Laboratories Introduction Persistent organic pollutants (POPs) are toxic chemicals

More information

CHAPTER FOUR ORGANIC ANALYTES

CHAPTER FOUR ORGANIC ANALYTES CHAPTER FOUR ORGANIC ANALYTES allowed flexibility in the choice of apparatus, reagents, and supplies. In addition, unless specified in a regulation, the use of SW-846 methods is not mandatory in response

More information

Semivolatile Organics Analysis Using an Agilent J&W HP-5ms Ultra Inert Capillary GC Column

Semivolatile Organics Analysis Using an Agilent J&W HP-5ms Ultra Inert Capillary GC Column Semivolatile Organics Analysis Using an Agilent J&W HP-5ms Ultra Inert Capillary GC Column Application Note Environmental Author Doris Smith and Kenneth Lynam Agilent Technologies, Inc. 285 Centerville

More information

The Standard for ph Method Development

The Standard for ph Method Development The Standard for ph Method Development High Efficiency Excellent Lifetime ph Stable - www.phenomenex.com/gemini U.S. Patent No.,, Setting the Standard for ph Method Development Gemini columns are rugged

More information

The Suite for Environmental GC Analysis

The Suite for Environmental GC Analysis The Suite for Environmental GC Analysis SGE Environmental GC Columns Performance Selectivity Delivery Promise www.sge.com SGE Environmental GC Columns The Suite for Environmental GC Analysis SGE GC Columns

More information

6-24 hours e. Coliform, Fecal and Total W, DW P,G Cool, 4 C, 0.008% Na 2 S 2 O 3. Fecal Streptococci W P,G Cool, 4 C, 0.

6-24 hours e. Coliform, Fecal and Total W, DW P,G Cool, 4 C, 0.008% Na 2 S 2 O 3. Fecal Streptococci W P,G Cool, 4 C, 0. Coliform, Colilert, P, Bottle or Bag Cool, 4 C, 0.008% Na 2 S 2 O 3 d Coliform, Fecal and Total, P,G Cool, 4 C, 0.008% Na 2 S 2 O 3 d Fecal Streptococci P,G Cool, 4 C, 0.008% Na 2 S 2 O 3 d INORGANIC TESTS

More information

Capillary GC Column Selection and Method Development A Primer on Column Parameters and Instrument Conditions

Capillary GC Column Selection and Method Development A Primer on Column Parameters and Instrument Conditions Capillary GC Column Selection and Method Development A Primer on Column Parameters and Instrument Conditions Michael D. Buchanan September 11, 2014 sigma-aldrich.com/analytical 2012 Sigma-Aldrich Co. All

More information

METHOD 8000B DETERMINATIVE CHROMATOGRAPHIC SEPARATIONS

METHOD 8000B DETERMINATIVE CHROMATOGRAPHIC SEPARATIONS METHOD 8000B DETERMINATIVE CHROMATOGRAPHIC SEPARATIONS 1.0 SCOPE AND APPLICATION 1.1 Method 8000 is not a determinative method but instead provides guidance on analytical chromatography and describes calibration

More information

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis A. Caruso, M. Santoro, P. Magni, S. Pelagatti, and R. Facchetti Thermo Fisher Scientific, Milan,

More information

Class III Wastewater Laboratory Analyst Examination Study Guide 2008

Class III Wastewater Laboratory Analyst Examination Study Guide 2008 Class III Wastewater Laboratory Analyst Examination Study Guide 2008 Specific laboratory analyses included on Class III Exam: All Information and tests from Class I and Class II Plus the following - Biological

More information

Technical Report. Abstract: Pu Wang 1, Huizhong Sun 1, Qinghua Zhang 1, Feifei Tian 2, Lei Cao 2

Technical Report. Abstract: Pu Wang 1, Huizhong Sun 1, Qinghua Zhang 1, Feifei Tian 2, Lei Cao 2 C46-E299 Technical Report Determination of Polychlorinated Dibenzo-p-dioxins and Dibenzofurans (PCDD/Fs) in Foodstuffs and Animal Feed Using a Triple Quadrupole GCMS-TQ8040 System with Smart MRM Transforms

More information

Optimizing GC Parameters for Faster Separations with Conventional Instrumentation

Optimizing GC Parameters for Faster Separations with Conventional Instrumentation Optimizing GC Parameters for Faster Separations with Conventional Instrumentation Anila I. Khan, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 243 Key Words TraceGOLD fast GC analysis

More information

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling Andrea Caruso and Massimo Santoro, Thermo Fisher Scientific, Milan, Italy Application Note 1316 Key

More information

USP <467> Headspace Residual Solvent Assay with a HT3 Headspace Instrument

USP <467> Headspace Residual Solvent Assay with a HT3 Headspace Instrument Application Note Abstract The US Pharmacopeia recently released USP as the current monograph for determining residual solvents in pharmaceutical products by static headspace. The USP classified these

More information

PosterReprint INTRODUCTION

PosterReprint INTRODUCTION INTRODUCTION 'Dioxins' refers to a group of chemical compounds that share certain similar chemical structures and biological characteristics. Several hundred of these toxic compounds exist and are members

More information

ENVIRONMENTAL analysis

ENVIRONMENTAL analysis ENVIRONMENTAL analysis Analyzing Wastewater Effluents for PAH s and PBDE s Using the Agilent 7000 Triple Quadrupole GC/MS Solutions for Your Analytical Business Markets and Applications Programs Authors

More information

Application Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS

Application Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS Application Note #1820230 Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS GC-MS Introduction USEPA Method 8270 [1] for semivolatiles is is used by by laboratories to measure

More information

Determination of VOC in Artificial Runway by Multiple Headspace Extraction-GC/MS. Gas Chromatography/ Mass Spectrometry APPLICATION.

Determination of VOC in Artificial Runway by Multiple Headspace Extraction-GC/MS. Gas Chromatography/ Mass Spectrometry APPLICATION. APPLICATION NOTE Gas Chromatography/ Mass Spectrometry Author: Kira. Yang PerkinElmer, Inc. Shanghai, China Determination of VOC in Artificial Runway by Multiple Headspace Extraction-GC/MS Introduction

More information

A Review of Solid Phase Sorbents Over Time As Applied to Environmental Applications. Page 1 Biotage

A Review of Solid Phase Sorbents Over Time As Applied to Environmental Applications. Page 1 Biotage A Review of Solid Phase Sorbents Over Time As Applied to Environmental Applications Page 1 Bill Jones 8 August 2018 Abstract» Sample preparation using solid phase extraction (SPE) has been in use for several

More information

Grace GC Capillary Column Families

Grace GC Capillary Column Families Grace GC Capillary Column Families Alltech Heliflex High-Performance, Widest Selection of Phases Alltech Econo-Cap Best Value, Popular Phases Grace offers two lines of capillary columns to suit every application

More information

Selection of a Capillary

Selection of a Capillary Selection of a Capillary GC Column - Series 3 Mark Sinnott Application Engineer March 19, 2009 Page 1 Typical Gas Chromatographic System Mol-Sieve Traps Fixed Restrictors Regulators Injection Port Detector

More information

Multi-residue Analysis for PAHs, PCBs and OCPs on Agilent J&W FactorFour VF-Xms

Multi-residue Analysis for PAHs, PCBs and OCPs on Agilent J&W FactorFour VF-Xms Multi-residue Analysis for PAHs, PCBs and OCPs on Agilent J&W FactorFour VF-Xms Application Note Author Laura Provoost Agilent Technologies, Inc. Introduction In multi-residue analysis different groups

More information

40 % OFF. Upgrade to Zebron GC Columns. Equivalent Selectivity. Better Service. ZB-1ms ZB-5 ZB-624. ZB-5ms ZB-WAX ZB-1.

40 % OFF. Upgrade to Zebron GC Columns. Equivalent Selectivity. Better Service. ZB-1ms ZB-5 ZB-624. ZB-5ms ZB-WAX ZB-1. Upgrade to Zebron GC Columns Equivalent Selectivity. Better Service. ZB-ms ZB-5 ZB-64 ZB- 40 % OFF Zebron GC columns ZB-WAX ZB-5ms * Expires: October 30, 009 Please Mention Offer Code: ZBE009 * Offer applies

More information

Determination of Volatile Aromatic Compounds in Soil by Manual SPME and Agilent 5975T LTM GC/MSD

Determination of Volatile Aromatic Compounds in Soil by Manual SPME and Agilent 5975T LTM GC/MSD Determination of Volatile Aromatic Compounds in Soil by Manual SPME and Agilent 5975T LTM GC/MSD Application Note Environmental Author Suli Zhao, Andy Zhai Agilent Technologies Co., Ltd. 412 Yinglun Road

More information

Fast USEPA 8270 Semivolatiles Analysis Using the 6890/5973 inert GC/MSD with Performance Electronics Application

Fast USEPA 8270 Semivolatiles Analysis Using the 6890/5973 inert GC/MSD with Performance Electronics Application Fast USEPA 8270 Semivolatiles Analysis Using the 6890/5973 inert GC/MSD with Performance Electronics Application Environmental Analysis Author Mike Szelewski Agilent Technologies, Inc. 2850 Centerville

More information

Faster Semivolatiles Analysis with a Scaled- Down Method and GC Accelerator Kit

Faster Semivolatiles Analysis with a Scaled- Down Method and GC Accelerator Kit Faster Semivolatiles Analysis with a Scaled- Down Method and GC Accelerator Kit Analysis times for semivolatile compounds can limit sample throughput and decrease overall lab productivity. You can significantly

More information

Determination of Organochlorine Pesticides and Polychlorinated Biphenyls Using GC/MS/MS Operated in the MRM Mode

Determination of Organochlorine Pesticides and Polychlorinated Biphenyls Using GC/MS/MS Operated in the MRM Mode PO-CON1610E Determination of Organochlorine Pesticides and Polychlorinated Biphenyls Using GC/MS/MS Operated in the MRM Mode Pittcon 2016 1110-2 Brahm Prakash, William Lipps, Di Wang, Shilpi Chopra, Nicole

More information

ApplicationNOTE Abstract

ApplicationNOTE Abstract Abstract It has long been known that a range of non-native, stable, saturated hydrocarbon biomarkers present in crude oil extracts could be used to identify the original facie from which the oil was formed.

More information

SUPELCO. The Analysis of all 209 PCB Congeners on the SPB -Octyl and MDN -5S Capillary Columns. Katherine K. Stenerson and Leonard M.

SUPELCO. The Analysis of all 209 PCB Congeners on the SPB -Octyl and MDN -5S Capillary Columns. Katherine K. Stenerson and Leonard M. SUPELCO The Analysis of all 209 PCB Congeners on the SPB -Octyl and MDN -5S Capillary Columns Katherine K. Stenerson and Leonard M. Sidisky Supelco, Supelco Park, Bellefonte, PA USA 2000 Sigma-Aldrich

More information

Understanding Gas Chromatography

Understanding Gas Chromatography Understanding Gas Chromatography What is Really Going on Inside the Box? Simon Jones GC Applications Engineer Page 1 Group/Presentation Title Month ##, 200X ?? K? Page 2 Typical GC System Gas supply Injector

More information

Selection of a Capillary GC Column

Selection of a Capillary GC Column Selection of a Capillary GC Column Mark Sinnott Application Engineer March 13, 2008 Page 1 Typical Gas Chromatographic System Mol-Sieve Traps Fixed Restrictors Regulators Injection Port Detector Electrometer

More information

Detection of Environmental Contaminants Caused by the Oil Spill in the Gulf of Mexico by GC and Hplc

Detection of Environmental Contaminants Caused by the Oil Spill in the Gulf of Mexico by GC and Hplc Detection of Environmental Contaminants Caused by the Oil Spill in the Gulf of Mexico by GC and Hplc Sky Countryman, Ngoc Nguyen, Jeff Layne, Kory Kelly, and Zeshan Aqeel Phenomenex, Inc., 411 Madrid Ave.,

More information

AppNote 2/2000. Stir Bar Sorptive Extraction (SBSE) applied to Environmental Aqueous Samples

AppNote 2/2000. Stir Bar Sorptive Extraction (SBSE) applied to Environmental Aqueous Samples AppNote 2/2 Stir Bar Sorptive Extraction (SBSE) applied to Environmental Aqueous Samples Pat Sandra Department of Organic Chemistry, University of Gent, Krijgslaan 281 S4, B-9 Gent, Belgium Erik Baltussen

More information

Non-Potable Water A2LA Certificate

Non-Potable Water A2LA Certificate COLOR Color Biochemical Oxygen Demand (BOD); Carbonaceous DEMAND BOD; Chemical Oxygen Demand (COD); Total Organic Carbon (TOC) HEXAVALENT CHROMIUM INORGANIC NUTRIENTS LOW-LEVEL MERCURY METALS I & II METALS

More information

So Many Columns! How Do I Choose? Daron Decker Chromatography Technical Specialist

So Many Columns! How Do I Choose? Daron Decker Chromatography Technical Specialist So Many Columns! How Do I Choose? Daron Decker Chromatography Technical Specialist GC Columns Wall Coated Open Tubulars Liquid phase coated capillaries Internal Diameter 0.05 0.53mm Length 5m 100m Porous

More information

Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor

Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor Application Note Pesticides Authors Charlie Spanjers and Paul Dauenhauer University of Minnesota, Twin Cities

More information

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011 ?? Kβ? Page 1 Typical GC System Gas supply Injector Detector Data handling GAS Column Oven Page 2 CARRIER GAS Carries the solutes down the column Selection and velocity influences efficiency and retention

More information

Appendices References...49 Glossary Equations

Appendices References...49 Glossary Equations Table of Contents List of Tables...2 List of Figures...2 Column Selection General Considerations for Column Selection... 3-11 Your Zebron Capillary GC Column... 12-29 Column Installation Pre-Installation

More information

Polychlorinated biphenyls (PCBs)

Polychlorinated biphenyls (PCBs) Polychlorinated biphenyls (PCBs) 3 2 2 3 4 4 ()n 5 6 6 5 ()m Polychlorinated biphenyls (PCBs) have been the subject of a broad range of studies and investigations because of their environmental persistency

More information

Accurate Analysis of Fuel Ethers and Oxygenates in a Single Injection without Calibration Standards using GC- Polyarc/FID. Application Note.

Accurate Analysis of Fuel Ethers and Oxygenates in a Single Injection without Calibration Standards using GC- Polyarc/FID. Application Note. Accurate Analysis of Fuel Ethers and Oxygenates in a Single Injection without Calibration Standards using GC- Polyarc/FID Application Note Volatile Organic Compounds (VOCs) Author Andrew Jones Activated

More information

Introduction and Principles of Gas Chromatography

Introduction and Principles of Gas Chromatography Introduction and Principles of Gas Chromatography Jaap de Zeeuw Restek, Middelburg, The Netherlands Jaap.dezeeuw@restek.com Definition and Uses of Gas Chromatography GC Components and Types of Columns

More information

The Third Dimension of Information Vol. IV Applications with the Agilent Technologies Atomic Emission Detector. O H Cl. Fe Se

The Third Dimension of Information Vol. IV Applications with the Agilent Technologies Atomic Emission Detector. O H Cl. Fe Se The Third Dimension of Information Vol. IV Applications with the Agilent Technologies Atomic Emission Detector O H Cl Sn Fe Se S Author: Bernhard Rothweiler, Agilent Technologies Deutschland GmbH Index:

More information

Get Selective. By Jaap de Zeeuw

Get Selective. By Jaap de Zeeuw 34 Get Selective Modern narrow bore columns have made chromatographers lazy when it comes to stationary phase selection. Here s how getting back to basics in gas chromatography by using selectivity can

More information

Application Note. Abstract. Introduction. Determination of Polycyclic Aromatic Hydrocarbons in Seafood by an Automated QuEChERS Solution

Application Note. Abstract. Introduction. Determination of Polycyclic Aromatic Hydrocarbons in Seafood by an Automated QuEChERS Solution Application Note Abstract Determination of Polycyclic Aromatic Hydrocarbons in Seafood by an Automated QuEChERS Solution Page 1 Polycyclic Aromatic Hydrocarbons (PAHs) are a large group of organic compounds

More information

Validation of GC-MS/MS for Detection and Confirmation of Low-Level Dioxins

Validation of GC-MS/MS for Detection and Confirmation of Low-Level Dioxins Validation of GC-MS/MS for Detection and Confirmation of Low-Level Dioxins Cristian Cojocariu, 1 Paul Silcock, 1 and Alexander Kotz 2 1 Thermo Fisher Scientific, Runcorn, U.K. 2 European Union Reference

More information

Trim Time Not Columns Multiresidue Pesticides Analysis with an Intuvo GC/TQ

Trim Time Not Columns Multiresidue Pesticides Analysis with an Intuvo GC/TQ Trim Time Not Columns Multiresidue Pesticides Analysis with an Intuvo GC/TQ Courtney Milner, Ph.D. Agilent Technologies Santa Clara, CA ASMS 2018 VIP Session 1 Agenda Pesticide analysis trends Targeted

More information

[ Care and Use Manual ]

[ Care and Use Manual ] Oasis HLB DISKS I. Introduction Oasis HLB is a Hydrophilic-Lipophilic-Balanced, water-wettable, reversed-phase sorbent for all your SPE needs. It is made from a specific ratio of two monomers, the hydrophilic

More information

PhenogelTM Non-Aqueous GPC/SEC Columns

PhenogelTM Non-Aqueous GPC/SEC Columns PhenogelTM Non-Aqueous GPC/SEC Columns Improve Resolution Wide solvent compatibility Temperature stability up to 140 C Narrow bore columns available for reduced solvent consumption Phenogel GPC Materials

More information

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL DATE

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL DATE of 3 The required detection limit is generally that of the approved method's detection limit and a value less than the regulatory limit for the analyte. For the Drinking Water Category, the Program has

More information

Presentation Title. Isotope Dilution: Where it doesn t work Where we should expand its use. August 10, David I. Thal Principal Chemist

Presentation Title. Isotope Dilution: Where it doesn t work Where we should expand its use. August 10, David I. Thal Principal Chemist Presentation Title Isotope Dilution: Subtitle Where / Author it works Where it doesn t work Where we should expand its use August 10, 2017 David I. Thal Principal Chemist Isotope Dilution - Definitions

More information

HRMS PBDE Analysis on a Thermo DFS. Dave Hope, Pacific Rim Laboratories Inc

HRMS PBDE Analysis on a Thermo DFS. Dave Hope, Pacific Rim Laboratories Inc HRMS PBDE Analysis on a Thermo DFS Dave Hope, Pacific Rim Laboratories Inc Outline PBDE what is it and why are we interested in it EPA 1614 HRMS analysis Considerations for Thermo DFS / Trace GC Food analysis

More information

Determination of Polybrominated Diphenylethers (PBDE) in Sediment and Sewage Sludge Application

Determination of Polybrominated Diphenylethers (PBDE) in Sediment and Sewage Sludge Application Deteration of Polybroated Diphenylethers (PBDE) in Sediment and Sewage Sludge Application Environmental Authors Sonia Wanner Centre d'analyse et de Recherche (CAR) 76 route du Rhin F-67441 Illkirch France

More information

Choosing the Correct GC Column Dimensions and Stationary Phase

Choosing the Correct GC Column Dimensions and Stationary Phase Choosing the Correct GC Column Dimensions and Stationary Phase Daron Decker Chromatography Technical Specialist Page 1 Nothing is useless it can always serve as a bad example Custom Column: 150 m x 250

More information

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1 Application Note Meeting the Korean Method ES 04602.1b for Vinyl Chloride, Acrylonitrile, and Bromoform ( 염화비닐, 아크릴로니트릴, 브로모포름 ) with Static and Dynamic Headspace GC/MS Roger Bardsley, Applications Chemist;

More information

GC/MS/MS Dioxin and Dioxin-like PCBs in Feed and Food. Jessica Westland, LSAG Applications Chemist

GC/MS/MS Dioxin and Dioxin-like PCBs in Feed and Food. Jessica Westland, LSAG Applications Chemist GC/MS/MS Dioxin and Dioxin-like PCBs in Feed and Food Jessica Westland, LSAG Applications Chemist What is a Dioxin? The term dioxins refers to a group of chemically and structurally related halogenated

More information

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application Analysis of Trace (mg/kg) Thiophene in Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application Petrochemical Authors James D. McCurry and Bruce D. Quimby Agilent Technologies

More information

Food analysis. Solutions for Your Analytical Business Markets and Applications Programs

Food analysis. Solutions for Your Analytical Business Markets and Applications Programs Food analysis HIGH SENSITIVITY ANALYSIS OF TRACE ORGANIC POLLUTANTS IN MUSSEL TISSUE USING THE 7010 TRIPLE QUADRUPOLE MASS SPECTROMETER Solutions for Your Analytical Business Markets and Applications Programs

More information

Product Brief. - Hydrocarbons alkanes, alkenes, alkynes, dienes including natural gas, refinery gas, liquified petroleum gas

Product Brief. - Hydrocarbons alkanes, alkenes, alkynes, dienes including natural gas, refinery gas, liquified petroleum gas Agilent Porous Polymer PLOT Columns: New Products, Expanded Uses, Prices Cut in Half! Product Brief Need improved resolution of small volatile compounds? Didn't try a PLOT column due to high price, short

More information

Slightly Polar Columns

Slightly Polar Columns 9000 Варна, ул.поп Харитон 47 e-mail : gea99@abv.bg www.geya99.com Slightly Polar Columns With the partnership of Teknokroma SLIGHTLY POLAR COLUMNS TRB-5 It is the most universal and versatile stationary

More information

Solid Phase Microextraction of Cyanogen Chloride and Other Volatile Organic Compounds in Drinking Water with Fast Analysis by GC-TOFMS

Solid Phase Microextraction of Cyanogen Chloride and Other Volatile Organic Compounds in Drinking Water with Fast Analysis by GC-TOFMS Solid Phase Microextraction of Cyanogen Chloride and Other Volatile Organic Compounds in Drinking Water with Fast Analysis by GC-TOFMS LECO Corporation; Saint Joseph, Michigan USA Key Words: GC-TOFMS,

More information

Helium conservation in volatile organic compound analysis using U.S. EPA Method 8260C

Helium conservation in volatile organic compound analysis using U.S. EPA Method 8260C APPLICATION NOTE 10441 Helium conservation in volatile organic compound analysis using U.S. EPA Method 8260C Authors Andrea Caruso, 1 Tommaso Albertini, 1 Jacob A. Rebholz 2 ; 1 Thermo Fisher Scientific,

More information