Take Your Food Testing to the Next Level

Size: px
Start display at page:

Download "Take Your Food Testing to the Next Level"

Transcription

1 GC Columns Take Your Food Testing to the Next Level Using Zebron GC Columns Featuring Pesticides FAMEs Essential Oils Flavors And more..

2 Pesticide Screening by GC-MS ,9 pesticides in a single run! , , App ID 68 min Column: Zebron ZB-MultiResidue - Dimensions: 0 meter x 0. mm x 0. µm Part No.: 7HG-G06- Injection: 60 C, µl Recommended Liner: Zebron PLUS Single Taper with Wool, mm Liner Part No.: AG-0A-0 (for Agilent Systems) Septum: AG0-697 (PhenoRed -00) Inlet Seal: AG0-860 (Easy Seals ) Carrier Gas: 0.9 ml/min (constant flow) Oven Program: 80 C for 0. min to 0 0 C/min to 0 C/min to 0 C/min for min Detector: 0 C; -00 amu Sample: Analytes are ppm in dichloromethane See entire analyte list and technical note at: TN-0 Melamine From Dog Food by GC-MS Column: Zebron ZB-MSplus Dimensions: 0 meter x 0. mm x 0. μm Part No.: 7HG-G00- Injection: 80 C, μl Recommended Liner: Zebron PLUS Single Taper Z-Liner Liner Part No.: AG-0A-0 Carrier Gas: ml/min (constant flow) Oven Program: 7 C for min to 0 C/min hold for min Detection: 0 C Sample:. Cyanuric Acid. Ammelide. Ammeline. Melamine. Benzoguanamine 9 0 min App ID Phenomenex l WEB:

3 Fast FAMEs Analysis Fatty Acids from Infant Formula by GC-FID Column: Zebron ZB-FAME Dimensions: 0 meter x 0. mm x 0.0 µm Part No.: 7HG-G0-0 Injection: Split 0 C, µl Recommended Liner: Zebron PLUS Single Taper with Wool Liner Part No.: AG-0A-0 Carrier Gas: ml/min (constant flow) Oven Program: 00 C for min to 0 0 C/min to 90 C/min to 60 0 C/min for min Detector: 60 C Sample:. C8:0 6. C0:0. C:0*. C:0. C:0 6. C6:0 7. C8:0 8. C8: cis 9 9. C8: cis 9, 0. C8: cis 9,,. C0:0. C0: cis. C0: cis,8,,. C:0. C:0 6. C:6 cis,7,0,,6,9 *Internal standard min run time 7 App ID min Fatty Acids from Olive Olive Oil by GC-FID Column: Zebron ZB-FAME Dimensions: 60 meter x 0. mm x 0.0 μm Part No.: 7KG-G0-0 Injection: Split 0 C, μl Recommended Liner: Zebron PLUS Single Taper with Wool Liner Part No.: AG-0A-0 Carrier Gas: ml/min (constant flow) Oven Program: 00 C for min to 0 0 C/min to 90 C/min to 60 0 C/min for min Detector: 60 C Sample:. C:0*. C6:0. C6: cis 9. C8:0. C8: cis 9 6. C8: cis 9, 7. C8: cis 9,, 8. C0:0 9. C0: cis *Internal standard 6 App ID Phenomenex l WEB:

4 Essential Oils from Oranges by GC-MS Cold-Pressed Orange Oil Column: Zebron ZB-WAXplus Dimensions: 0 meter x 0.0 mm x 0.0 μm Part No.: 7CB-G0-0 Injection: Split 0 C, 0. μl Recommended Liner: Zebron PLUS Straight Z-Liner Liner Part No.: AG-0A00-0 Carrier Gas: 0. ml/min (constant flow) Oven Program: C for min to 0 0 C/min for min Detector: MSD; -0 amu Sample:. α-pinene. β-pinene. Sabinene. -Carene. β-myrcene 6. Limonene 7. β-phellandrene 8. Octanal 9. Nonanal 0. Limonene Oxides. Citronellal. Decanal. α-cubebene. Linalool. β-cubebene 6. Octanol 7. Germacrene 8. Caryophyllene 9. trans-p-mentha-,8-dienol 0. cis-p-mentha-,8-dienol. Gerenial. α-terpineol. Dodecanal. Valencene. Citral 6. Carvone 7. Cadinene 8. Perillaldehyde 9. trans-carveol 0. cis-carveol. Perillol. Octanoic acid Great separation and fast run times, App ID min Flavors Screening by GC-MS min Test mix courtesy of Frutarom (UK) Ltd., Flavour Chemistry Laboratory. App ID 900 Column: Zebron ZB-WAX Dimensions: 0 meter x 0. mm x 0. µm Part No.: 7HG-G007- Injection: Split 0 C,.0 µl Recommended Liner: Zebron PLUS Straight Z-Liner Liner Part No.: AG-0A00-0 Carrier Gas: ml/min (constant flow) Oven Program: 0 C to 0 6 C/min for min Detector: 7 C Sample:. Acetone. Ethyl acetate. Ethanol. Decane. Ethyl butyrate 6. Limonene 7.,-Dimethylpyrazine 8. (Z)--Hexenol 9. Tetradecane 0. Acetic acid. Decanal. Propylene glycol. Ethyl decanoate. Neral. α-terpineol 6. Neryl Acetate 7. Geranial 8. Decanol 9. Valeric acid 0. Nonanoic acid. Decanoic acid. Vanillin. Anthracene Phenomenex l WEB:

5 Ordering Information Zebron ZB-FAME GC Columns to 80 7FD-G to 80 7HG-G to 80 7KG-G0-0 Zebron ZB-MSplus GC Columns to /0 7EG-G to /0 7FD-G to /0 7FD-G to /0 7HG-G to /0 7HG-G to /0 7HG-G to /0 7HM-G to /0 7HM-G to /0 7KG-G00- ZB-MultiResidue GC Columns ZB-MultiResidue- GC Columns to 0/0 7FD-G to 0/0 7HG-G to 0/0 7HM-G to 0/0 7HM-G to 0/0 7HK-G06-7 ZB-MultiResidue- GC Columns to 0/0 7HG-G to 0/0 7HM-G to 0/0 7HK-G07-7

6 Ordering Information Zebron ZB-WAXplus GC Columns to 0/60 7CB-G to 0/60 7EG-G to 0/0 7EK-G to 0/60 7FD-G to 0/60 7HG-G to 0/60 7HG-G to 0/60 7HM-G to 0/60 7HM-G to 0/0 7HM-G to 0/0 7HK-G to 0/60 7KG-G to 0/60 7KG-G to 0/60 7KG-G to 0/60 7KM-G to 0/60 7KM-G to 0/0 7KK-G0- Note: If you need a in. cage, simply add a (-B) after the part number, e.g., 7HG-G0--B. Some exceptions may apply. Agilent 680 and some SRI and process GC systems use only in. cages. Zebron ZB-FFAP GC Columns to 0/60 7EG-G to 0/60 7EM-G to 0/60 7EM-G to 0/60 7EK-G to 0/60 7HG-G to 0/60 7HM-G to 0/60 7HM-G to 0/60 7HM-G to 0/60 7HK-G to 0/60 7JM-G to 0/60 7KG-G009- Note: If you need a in. cage, simply add a (-B) after the part number, e.g., 7HG-G009--B. Some exceptions may apply. Agilent 680 and some SRI and process GC systems use only in. cages. If Zebron columns do not provide you with equivalent or better separations as compared to any other GC column of the same phase and comparable dimensions, return the column with comparative data within days for a FULL REFUND. More GC columns, kits, and accessories available at

7 GC Column Selection ZB-6 ZB- Essentials Inferno Plus Unlimited ZB-0 ZB-WAX ZB-FAAP ZB- ZB-XLB-HT Inferno ZB-HT Inferno ZB-XLB-HT Inferno ZB-plus ZB-plus ZB-MSplus ZB-WAXplus ZB-FAME ZB-MultiResidue - ZB-MultiResidue - ZB-SemiVolatiles ZB-Bioethanol Food Safety Compound Class Analysis Recommended Column Pesticides & Antimicrobials Environmental Contaminants Food Contact Materials Additives & Preservatives Process Contaminants Multi-Residue Pesticide Screening Organochlorine Pesticides in Water Organochlorine Pesticides in Foods of Plant Origin Organophosphorus Pesticides in Foods of Plant Origin Triazine Pesticides in Water Triazine Pesticides in Foods of Plant Origin Chloramphenicol in Foods of Animal Origin Polybrominated Diphenyl Ethers (PBDEs) in Food Polychlorinated Biphenyls (PCBs) in Water Polychlorinated Dibenzo-dioxins (PCDDs) in Food Polychlorinated Dibenzo-furans (PCDFs) in Food Polycyclic Aromatic Hydrocarbons (PAHs) in Water Food Packaging Volatiles Melamine in Food Cyanuric Acid in Food Phthalates in Food Residual Solvents in Food Bisphenol A & F (BPA/BPF) in Food Parabens in Food Chloropropanols (-MCPD) in Food Flavor Additives (Borneol) Phenolic Antioxidants (BHA & BHT) in Food Tocopherols in Food Acrylamide in Foods Acrylamide, Acrylonitrile, and Acrolein in Water Benzene in Food Glycols in Food Hormones Steroid Hormones in Food Compound Class Analysis Recommended Column Acids & FAMEs Cis/Trans FAMEs Food Industry Fatty Acid Methyl Esters (FAMEs) Marine Oil Fatty Acid Methyl Esters (FAMEs) Saw Palmetto Fatty Acid Methyl Esters (FAMEs) Food Quality Free Fatty Acids Essential Fatty Acids (EFAs) Omega- and Omega-6 Triglycerides Butter Triglycerides Canola Oil Triglycerides Olive Oil Triglycerides Peanut Oil Triglycerides Alcoholic Beverages Cognac Compounds Distilled Liquor Screen Ethanol in Beer Sulfur in Beer Whiskey Compounds Wine Compounds Other Acids Organic Acids Amino Acids Sterols Sterols in Lard Sterols in Margarine Sterols in Olive Oil Sterols in Peanut Butter Sugars Alditol Acetates Trimethylsilyl (TMS) Sugars Compound Class Analysis Recommended Column Flavors & Fragrances Essential Oils Cold-Pressed Orange Oil Ginkgo Biloba Oil Lavender Oil Peppermint Oil Rose Oil Spearmint Oil Ylang Ylang Oil Flavors Flavors Screening Flavor Allergens Flavor Volatiles Alcoholic Beverage Profile Honey Profile Fragrances Fragrance Screening Fragrance Allergens

8 GC Columns Take Your Food Testing to the Next Level Using Zebron GC Columns Australia t: +6 (0)-98-6 f: +6 (0)-98-6 Austria t: + (0)-9-0 f: + (0)-9-00 anfrage@phenomenex.com Belgium t: + (0) 0 0 (French) t: + (0) 8666 (Dutch) f: + (0)0-879 beinfo@phenomenex.com Canada t: + (800) -68 f: + (0) info@phenomenex.com China t: f: +86 (0) -0 phen@agela.com Denmark t: f: nordicinfo@phenomenex.com Finland t: +8 (0) f: nordicinfo@phenomenex.com France t: + (0) f: + (0) 0 09 franceinfo@phenomenex.com Germany t: +9 (0) f: +9 (0) anfrage@phenomenex.com India t: +9 (0) f: +9 (0)0-0 indiainfo@phenomenex.com Ireland t: + (0) 7 0 f: eireinfo@phenomenex.com Luxembourg t: + (0) f: + (0)0-879 nlinfo@phenomenex.com Mexico t: f: tecnicomx@phenomenex.com The Netherlands t: + (0) f: + (0)0-879 nlinfo@phenomenex.com New Zealand t: +6 (0) f: +6 (0) nzinfo@phenomenex.com Norway t: f: nordicinfo@phenomenex.com Puerto Rico t: + (800) -HPLC f: + (0) info@phenomenex.com Spain t: f: espinfo@phenomenex.com Sweden t: +6 (0) f: nordicinfo@phenomenex.com United Kingdom t: + (0)6-067 f: + (0) ukinfo@phenomenex.com USA t: + (0) -0 f: + (0) info@phenomenex.com All other countries Corporate Office USA t: + (0) -0 f: + (0) info@phenomenex.com Italy t: f: italiainfo@phenomenex.com Phenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department at international@phenomenex.com BR09907_W Terms and Conditions Subject to Phenomenex standard terms & conditions, which may be viewed at www. phenomenex.com/termsandconditions. Trademarks Inferno, MultiResidue, Z-Liner, EasySeals, PhenoRed, plus, plus, MSplus, WAXplus, and Zebron are trademarks of Phenomenex. Agilent is a registered trademark of Agilent Technologies, Inc. 07 Phenomenex, Inc. All rights reserved.

Fast, Accurate Environmental Testing

Fast, Accurate Environmental Testing GC Columns Fast, Accurate Environmental Testing Using Zebron GC Columns Featuring Pesticides Diesel Range Organics Semivolatiles Dioxane And more.. www.phenomenex.com/environmental Semi-Volatile Organic

More information

Accurate, Reproducible Results for Environmental Methods with Zebron GC Columns

Accurate, Reproducible Results for Environmental Methods with Zebron GC Columns Accurate, Reproducible Results for Environmental Methods with Zebron GC Columns BUY NOW AND SAVE! Length Sale Price* 10-15 meter $ 199 30 meter $ 399 60 meter $ 599 *Offer valid only for addressee, limit

More information

Analysis. Priority LC GC. Zebron PAH Accurately quantitate EU and EPA PAHs in less than 28 minutes

Analysis. Priority LC GC. Zebron PAH Accurately quantitate EU and EPA PAHs in less than 28 minutes Priority Analysis LC GC Core-Shell Technology GC Columns Kinetex PAH Expanded resolution with chemical selectivity specifically for PAHs Increased throughput and sensitivity with core-shell technology

More information

AGGREGATE ANALYSIS. Biologics Workflow. by Size Exclusion Chromatography

AGGREGATE ANALYSIS. Biologics Workflow. by Size Exclusion Chromatography Biologics Workflow AGGREGATE ANALYSIS by Size Exclusion Chromatography New biozen SEC columns provide: High efficiency on both HPLC and UHPLC Extreme inertness and robustness Finely tuned high and low

More information

New ZB-5HT Inferno The World s Highest Temperature Non-Metal GC Column

New ZB-5HT Inferno The World s Highest Temperature Non-Metal GC Column New ZB-5HT Inferno The World s Highest Temperature Non-Metal GC Column The World's First Non-metal 5% Phenyl Phase GC Column Rated to 430 C * Specially processed for thermal stability up to 430 C A true

More information

APPLICATIONS TN Peptide Purification Method Development: Application for the Purification of Bivalirudin. Introduction

APPLICATIONS TN Peptide Purification Method Development: Application for the Purification of Bivalirudin. Introduction Peptide Purification Method Development: Application for the Purification of Bivalirudin Marc Jacob, Joshua Heng, and Tivadar Farkas Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 91 USA In this technical

More information

The BIG GC Special. Details, Playoff Specials, and Early Bird Discounts Inside! Expires: December 20, 2013 Mention Offer Code: ZBNF1213.

The BIG GC Special. Details, Playoff Specials, and Early Bird Discounts Inside! Expires: December 20, 2013 Mention Offer Code: ZBNF1213. The BIG GC Special Details, Playoff Specials, and Early Bird Discounts Inside! Exclusive Savings on Zebron GC Columns for any phase new to your company* Length 10-15 Meter 30 Meter 60 Meter Sale Price

More information

Your Reversed Phase Method

Your Reversed Phase Method PLC Columns for Your Reversed Phase Method Balanced Non-Polar & Polar Selectivity Strong Non-Polar & Polar Selectivity Strong Polar & Aromatic Selectivity Unique Isomeric & alogenated Selectivity Robust

More information

Quick and Simple Cleanup for. Medicinal Chemistry. It s BIG.

Quick and Simple Cleanup for. Medicinal Chemistry. It s BIG. Quick and Simple Cleanup for Medicinal It s IG. Guaranteed Cleanup of Post Synthesis Reactions Strata -XL Giga s are designed to make Medicinal easy! With Strata Giga tubes I ve been able to purify a compound

More information

APPLICATIONS TN Separation and Quantitation of Physiologic Cobalamins (Vitamin B 12

APPLICATIONS TN Separation and Quantitation of Physiologic Cobalamins (Vitamin B 12 APPLICATIONS Separation and Quantitation of Physiologic Cobalamins (Vitamin B 12 in Dietary Supplements by LC/MS/MS using Synergi Fusion-RP Column Xianrong (Jenny Wei Senior Scientist PhenoLogix applications

More information

Gemini-NX Performance paired with Axia Technology

Gemini-NX Performance paired with Axia Technology Si Si Si Si Si Si Si C Si Si Si Si Si Gemini-NX Performance paired with Axia Technology Gemini -NX Axia Packed Technology Improves Yield, Throughput, and Column Lifetime Ideal Purification Platform While

More information

3 Ways To Choose. All GC 5 Phases Are Not The Same! ZB-5. ZB-5MSi. ZB-5HT Inferno. ZB-5ms ZB-5MSPLUS. ZB-SemiVolatiles.

3 Ways To Choose. All GC 5 Phases Are Not The Same! ZB-5. ZB-5MSi. ZB-5HT Inferno. ZB-5ms ZB-5MSPLUS. ZB-SemiVolatiles. 3 Ways To Choose All GC 5 Phases Are Not The Same! ZB-5 ZB-5M ZB-5HT Inferno ZB-5ms ZB-5MSPLUS ZB-SemiVolatiles www.phenomenex.com/5phase Choosing Your 5 Phase Is Easy Use the NEW GC Column Finder web

More information

4. Place a 20 ml VOA vial in position 1 of the tray. 5. Place a 6 ml C18-E cartridge in position 1 of the carousel.

4. Place a 20 ml VOA vial in position 1 of the tray. 5. Place a 6 ml C18-E cartridge in position 1 of the carousel. Increase Throughput and Recoveries for EPA Method 508.1 with Automated Extraction using Strata C18-E SPE Cartridges and Zebron ZB-MultiResidue GC Columns Kali Tudela Phenomenex, Inc., 411 Madrid Ave.,

More information

APPLICATIONS TN Lux Cellulose-2 or -4 Cellulose tris (3-chloro-4-methylphenylcarbamate) or (4-chloro-3-methylphenylcarbamate)

APPLICATIONS TN Lux Cellulose-2 or -4 Cellulose tris (3-chloro-4-methylphenylcarbamate) or (4-chloro-3-methylphenylcarbamate) T-1079 APPLICATI Method Development for Reversed Phase Chiral LC/M/M Analysis of tereoisomeric Pharmaceutical Compounds with Polysaccharide-based tationary Phases Philip J. Koerner, Kari Carlson, Liming

More information

APPLICATIONS TN HPLC Conditions. Lux Cellulose-1 Cellulose tris(3,5-dimethylphenylcarbamate)

APPLICATIONS TN HPLC Conditions. Lux Cellulose-1 Cellulose tris(3,5-dimethylphenylcarbamate) T-147 APPLICATIS Alternative Selectivity of Chiral Stationary Phases Based on Cellulose tris(3-chloro-4-methylphenylcarbamate) and Cellulose tris(3,5-dimethylphenylcarbamate) Liming Peng, Tivadar Farkas

More information

Experience the Zebron Difference

Experience the Zebron Difference Experience the Zebron Difference Premier GC Column Selection Guide www.phenomenex.com/gc Introducing the Zebron Experience Proven Performance Zebron GC columns are engineered by expert Phenomenex GC scientists

More information

Rapid Analysis of Food and Fragrances Using High-Efficiency Capillary GC Columns. Application. Authors. Abstract. Introduction

Rapid Analysis of Food and Fragrances Using High-Efficiency Capillary GC Columns. Application. Authors. Abstract. Introduction Rapid Analysis of Food and Fragrances Using High-Efficiency Capillary GC Columns Application Food, Flavors and Fragrances Authors Mark Sinnott and Simon Jones Agilent Technologies, Inc. 9 Blue Raving Road

More information

40 % OFF. Upgrade to Zebron GC Columns. Equivalent Selectivity. Better Service. ZB-1ms ZB-5 ZB-624. ZB-5ms ZB-WAX ZB-1.

40 % OFF. Upgrade to Zebron GC Columns. Equivalent Selectivity. Better Service. ZB-1ms ZB-5 ZB-624. ZB-5ms ZB-WAX ZB-1. Upgrade to Zebron GC Columns Equivalent Selectivity. Better Service. ZB-ms ZB-5 ZB-64 ZB- 40 % OFF Zebron GC columns ZB-WAX ZB-5ms * Expires: October 30, 009 Please Mention Offer Code: ZBE009 * Offer applies

More information

The Standard for ph Method Development

The Standard for ph Method Development The Standard for ph Method Development High Efficiency Excellent Lifetime ph Stable - www.phenomenex.com/gemini U.S. Patent No.,, Setting the Standard for ph Method Development Gemini columns are rugged

More information

APPLICATIONS TN Increased Capabilities for the Analysis of Hormones in Drinking and Waste Water Using Solid Phase Extraction (SPE) and LC/MS/MS

APPLICATIONS TN Increased Capabilities for the Analysis of Hormones in Drinking and Waste Water Using Solid Phase Extraction (SPE) and LC/MS/MS Increased Capabilities for the Analysis of Hormones in Drinking and Waste Water Using Solid Phase Extraction (SPE) and LC/MS/MS Xianrong (Jenny) Wei Senior Scientist Jenny is a Senior Scientist in Phenomenex

More information

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis A. Caruso, M. Santoro, P. Magni, S. Pelagatti, and R. Facchetti Thermo Fisher Scientific, Milan,

More information

Fast and Accurate Analysis of PBDEs in a Single Run, Including

Fast and Accurate Analysis of PBDEs in a Single Run, Including Fast and Accurate Analysis of PBDEs in a Single Run, Including Kory Kelly, Adam Endeman, and Matthew Trass Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 90501 USA PO14700713_2 PO14400613_W_2 Abstract

More information

VGA-100 Instrument Detection Limits and Linearity

VGA-100 Instrument Detection Limits and Linearity VGA-100 Instrument Detection Limits and Linearity The VGA-100 is the world s first benchtop vacuum ultraviolet (VUV) spectrometer for gas chromatography (GC). It is a universal GC detector that provides

More information

Fast and Accurate Analysis of PBDEs in a Single Run, Including BDE-209

Fast and Accurate Analysis of PBDEs in a Single Run, Including BDE-209 Fast and Accurate Analysis of PBDEs in a Single Run, Including Kory Kelly, Xianrong (Jenny) Wei, and Matthew Trass Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 90501 USA PO16570913_W_2 PO14400613_W_2

More information

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software High Efficiency GC Columns Page 1 Variables for Shortening Run Times Stationary Phase Shorten Column Length

More information

APPLICATIONS TN Detection of Environmental Contaminants Caused by the Oil Spill in the Gulf of Mexico by GC and HPLC

APPLICATIONS TN Detection of Environmental Contaminants Caused by the Oil Spill in the Gulf of Mexico by GC and HPLC Detection of Environmental Contaminants Caused by the Oil Spill in the Gulf of Mexico by GC and HPLC Sky Countryman, Ngoc Nguyen, Jeff Layne, Kory Kelly, and Zeshan Aqeel Phenomenex, Inc., 411 Madrid Ave.,

More information

A New PEG GC Column with Improved Inertness Reliability and Column Lifetime Agilent J&W DB-WAX Ultra Inert Polyethylene Glycol Column

A New PEG GC Column with Improved Inertness Reliability and Column Lifetime Agilent J&W DB-WAX Ultra Inert Polyethylene Glycol Column A New PEG GC Column with Improved Inertness Reliability and Column Lifetime Agilent J&W DB-WAX Ultra Inert Polyethylene Glycol Column Competitive Comparison Authors Ngoc-A Dang and Allen K. Vickers Agilent

More information

Optimizing GC Parameters for Faster Separations with Conventional Instrumentation

Optimizing GC Parameters for Faster Separations with Conventional Instrumentation Optimizing GC Parameters for Faster Separations with Conventional Instrumentation Anila I. Khan, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 243 Key Words TraceGOLD fast GC analysis

More information

ApplicationNOTE Abstract

ApplicationNOTE Abstract Abstract It has long been known that a range of non-native, stable, saturated hydrocarbon biomarkers present in crude oil extracts could be used to identify the original facie from which the oil was formed.

More information

Ultra-Inert chemistry for Trace Level Analysis

Ultra-Inert chemistry for Trace Level Analysis Ultra-Inert chemistry for Trace Level Analysis Cikui Liang, Ph.D. Challenges and Needs of Today s Laboratories Challenges Qualification/quantification of trace samples Keep instrument up and running Needs

More information

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling Andrea Caruso and Massimo Santoro, Thermo Fisher Scientific, Milan, Italy Application Note 1316 Key

More information

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil Che Jinshui, 1 Deng Guifeng, 1 Liang Lina, 1 and Aaron Kettle, 2 1 Thermo Fisher Scientific (China)

More information

Enhance Resolution FOR POLYMER ANALYSIS, Guaranteed *

Enhance Resolution FOR POLYMER ANALYSIS, Guaranteed * Enhance Resolution FOR POLYMER ANALYSIS, Guaranteed * Remarkable Reproducibility Exceptional Efficiency Long Lifetimes Economically Priced www.phenomenex.com/phenogel Phenogel Non-Aqueous GPC/SEC Columns

More information

USP <467> Headspace Residual Solvent Assay with a HT3 Headspace Instrument

USP <467> Headspace Residual Solvent Assay with a HT3 Headspace Instrument Application Note Abstract The US Pharmacopeia recently released USP as the current monograph for determining residual solvents in pharmaceutical products by static headspace. The USP classified these

More information

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software GC Columns and Consumables Mark Sinnott Application Engineer January 8 th, 2008 Page 1 Questions to Ask

More information

PhenogelTM Non-Aqueous GPC/SEC Columns

PhenogelTM Non-Aqueous GPC/SEC Columns PhenogelTM Non-Aqueous GPC/SEC Columns Improve Resolution Wide solvent compatibility Temperature stability up to 140 C Narrow bore columns available for reduced solvent consumption Phenogel GPC Materials

More information

ApplicationNOTE A STUDY OF THE ANALYSIS OF POLYBROMINATED DIPHENYL ETHER FLAME RETARDANTS BY GC/MS/MS. Introduction. Materials and Methods

ApplicationNOTE A STUDY OF THE ANALYSIS OF POLYBROMINATED DIPHENYL ETHER FLAME RETARDANTS BY GC/MS/MS. Introduction. Materials and Methods Abstract The development of a GC/MS/MS method for the analysis of brominated flame retardants will be presented. Standard methods require the use of high resolution magnetic sector instrumentation, which

More information

Understanding Gas Chromatography

Understanding Gas Chromatography Understanding Gas Chromatography What is Really Going on Inside the Box? Simon Jones GC Applications Engineer Page 1 Group/Presentation Title Month ##, 200X ?? K? Page 2 Typical GC System Gas supply Injector

More information

IJPRD, 2011; Vol 3(7): October 2011 (51-55) International Standard Serial Number

IJPRD, 2011; Vol 3(7): October 2011 (51-55) International Standard Serial Number IJPRD, 2011; Vol 3(7): October 2011 (51-55) International Standard Serial Number 0974 9446 ----------------------------------------------------------------------------------------------------------------------------------------------------------------

More information

Improved Peak Shape Performance and Consistency for Analysis of Challenging Polar Compounds

Improved Peak Shape Performance and Consistency for Analysis of Challenging Polar Compounds Improved Peak Shape Performance and Consistency for Analysis of Challenging Polar Compounds Laura Provoost GC Columns Product Manager Agilent CrossLab Group Challenges when analyzing active polar compounds

More information

Mass Spectral Studies of Polypropylene Chromatographic Well Plates

Mass Spectral Studies of Polypropylene Chromatographic Well Plates Mass Spectral Studies of Polypropylene Chromatographic Well Plates Brian King, Thermo Fisher Scientific, Runcorn, Cheshire, UK Detlev Lennartz, Thermo Fisher Scientific, Langerwehe, Germany White Paper

More information

ApplicationNOTE ULTRA TRACE ANALYSIS OF DIOXINS AND FURANS IN HUMAN ADIPOSE TISSUE USING SFE-LC EXTRACTION/CLEANUP AND THE WATERS AUTOSPEC ULTIMA NT

ApplicationNOTE ULTRA TRACE ANALYSIS OF DIOXINS AND FURANS IN HUMAN ADIPOSE TISSUE USING SFE-LC EXTRACTION/CLEANUP AND THE WATERS AUTOSPEC ULTIMA NT Introduction Legislative limits for dioxins and furans are ever decreasing 1, providing a greater challenge for the dioxin analyst. The extraction and clean-up processes used by the analyst can be imperative

More information

AppNote 15/2012. Large Volume Injection with Solvent Venting - Application to Trace Detection of Analytes in Water INTRODUCTION

AppNote 15/2012. Large Volume Injection with Solvent Venting - Application to Trace Detection of Analytes in Water INTRODUCTION AppNote 15/2012 Large Volume Injection with Solvent Venting - Application to Trace Detection of Analytes in Water A. Hoffmann, K. MacNamara Gerstel GmbH & Co. KG, Eberhard-Gerstel-Platz 1, D-45473 Mülheim

More information

Discovering the Scent of Celery: HS-SPME, GC-TOFMS, and Retention Indices for the Characterization of Volatiles

Discovering the Scent of Celery: HS-SPME, GC-TOFMS, and Retention Indices for the Characterization of Volatiles Discovering the Scent of Celery: HS-SPME, GC-TOFMS, and Retention Indices for the Characterization of Volatiles LECO Corporation; Saint Joseph, Michigan USA Key Words: GC-TOFMS, GC-MS, Pegasus BT, HS-SPME,

More information

Trim Time Not Columns Multiresidue Pesticides Analysis with an Intuvo GC/TQ

Trim Time Not Columns Multiresidue Pesticides Analysis with an Intuvo GC/TQ Trim Time Not Columns Multiresidue Pesticides Analysis with an Intuvo GC/TQ Courtney Milner, Ph.D. Agilent Technologies Santa Clara, CA ASMS 2018 VIP Session 1 Agenda Pesticide analysis trends Targeted

More information

AppNote 2/2001. Stir Bar Sorptive Extraction: Enhancing Selectivity of the PDMS Phase KEYWORDS ABSTRACT

AppNote 2/2001. Stir Bar Sorptive Extraction: Enhancing Selectivity of the PDMS Phase KEYWORDS ABSTRACT AppNote 2/2001 Stir Bar Sorptive Extraction: Enhancing Selectivity of the PDMS Phase Edward Pfannkoch, Jacqueline Whitecavage Gerstel, Inc., 701 Digital Drive, Suite J, Linthicum, MD 21090, USA Andreas

More information

Multi-residue Analysis for PAHs, PCBs and OCPs on Agilent J&W FactorFour VF-Xms

Multi-residue Analysis for PAHs, PCBs and OCPs on Agilent J&W FactorFour VF-Xms Multi-residue Analysis for PAHs, PCBs and OCPs on Agilent J&W FactorFour VF-Xms Application Note Author Laura Provoost Agilent Technologies, Inc. Introduction In multi-residue analysis different groups

More information

HIGH SPEED GC-TOFMS FOR ESSENTIAL OILS PROFILING IN ROUTINE QUALITY ASSESSMENT

HIGH SPEED GC-TOFMS FOR ESSENTIAL OILS PROFILING IN ROUTINE QUALITY ASSESSMENT HIGH SPEED GC-TOFMS FOR ESSENTIAL OILS PROFILING IN ROUTINE QUALITY ASSESSMENT APPLICATION NOTE Authors: Daniela Cavagnino DANI Instruments SpA viale Brianza, 87 Cologno Monzese Milano Italy Fast GC-TOFMS

More information

Agilent J&W GC Column Selection Guide SPEED YOUR SELECTION WITH THIS ONE-STOP RESOURCE

Agilent J&W GC Column Selection Guide SPEED YOUR SELECTION WITH THIS ONE-STOP RESOURCE Agilent J&W GC Column Selection Guide SPEED YOUR SELECTION WITH THIS ONE-STOP RESOURCE Table of Contents The story behind Agilent J&W Advanced GC Columns... 1 Column Selection Principles... 3 Selecting

More information

Choosing the Correct GC Column Dimensions and Stationary Phase

Choosing the Correct GC Column Dimensions and Stationary Phase Choosing the Correct GC Column Dimensions and Stationary Phase Daron Decker Chromatography Technical Specialist Page 1 Nothing is useless it can always serve as a bad example Custom Column: 150 m x 250

More information

Column Dimensions. GC Columns and Consumables. Mark Sinnott Application Engineer. March 12, 2010

Column Dimensions. GC Columns and Consumables. Mark Sinnott Application Engineer. March 12, 2010 Secrets of GC Column Dimensions GC Columns and Consumables Mark Sinnott Application Engineer Folsom California March 12, 2010 Page 1 Secrets of GC Column Dimensions Do I have the right column phase? Resolution

More information

Understanding the Capillary GC Column: How to Choose the Correct Type and Dimension

Understanding the Capillary GC Column: How to Choose the Correct Type and Dimension Understanding the Capillary GC Column: How to Choose the Correct Type and Dimension Simon Jones Application Engineer Things to Consider Is it Volatile enough to chromatograph by GC? Is it a Gas or a Liquid?

More information

Stabilwax -MS Columns

Stabilwax -MS Columns Stabilwax -MS Columns Thermally Stable, High Polarity GC Columns for Flavor, Food, Fragrance, Industrial Chemical, and Solvent Analyses What s Inside New Stabilwax -MS columns...p. 2 3 Applications Fragrances...

More information

Guide to GC Column Selection and Optimizing Separations

Guide to GC Column Selection and Optimizing Separations Guide to GC Column Selection and Optimizing Separations WHICH COLUMN DO I NEED? Learn how to choose the right column the first time. Optimize separations for the best balance of resolution and speed. Troubleshoot

More information

environmental Rtx -CLPesticides and Rtx -CLPesticides2 Columns: The Ideal Confirmational Pair for Analyzing Polychlorinated Biphenyls (PCBs)

environmental Rtx -CLPesticides and Rtx -CLPesticides2 Columns: The Ideal Confirmational Pair for Analyzing Polychlorinated Biphenyls (PCBs) environmental #59120 Applications note Rtx -CLPesticides and Rtx -CLPesticides2 Columns: The Ideal Confirmational Pair for Analyzing Polychlorinated Biphenyls (PCBs) Polychlorinated biphenyls (PCBs) are

More information

Pesticides Analysis Using the Agilent 5977A Series GC/MSD

Pesticides Analysis Using the Agilent 5977A Series GC/MSD Pesticides Analysis Using the Agilent 5977A Series GC/MSD Application Note Food Testing and Agriculture Authors Jia-jia Wu and Wen-wen Wang Agilent Technologies Co. Ltd (China) Beijing, People s Republic

More information

Developing Large Volume Injection (LVI) in Split / Splitless Inlets. Philip J. Koerner Phenomenex Inc. NEMC 2014

Developing Large Volume Injection (LVI) in Split / Splitless Inlets. Philip J. Koerner Phenomenex Inc. NEMC 2014 Developing Large Volume Injection (LVI) in Split / Splitless Inlets Philip J. Koerner Phenomenex Inc. NEMC 2014 Goal To produce a method that provides the largest response of analytes that will produce

More information

Trajan SGE GC Columns

Trajan SGE GC Columns Trajan Scientific and Medical Trajan SGE GC Columns Trajan Scientific and Medical Our focus is on developing and commercializing technologies that enable analytical systems to be more selective, sensitive

More information

Product Brief. - Hydrocarbons alkanes, alkenes, alkynes, dienes including natural gas, refinery gas, liquified petroleum gas

Product Brief. - Hydrocarbons alkanes, alkenes, alkynes, dienes including natural gas, refinery gas, liquified petroleum gas Agilent Porous Polymer PLOT Columns: New Products, Expanded Uses, Prices Cut in Half! Product Brief Need improved resolution of small volatile compounds? Didn't try a PLOT column due to high price, short

More information

GC Resolution Do You See What I See?

GC Resolution Do You See What I See? GC Resolution Do You See What I See? Column Dimensions and Carrier Gas Optimization Deans Switch Page 1 Variables for Maximizing Resolution Optimized Stationary Phase Longer Column Length Decrease Internal

More information

AppNote 7/2003. Coupling Retention Time Locked Methods and Libraries to Automated SPME or SBSE for Analysis of Flavors and Fragrances KEYWORDS

AppNote 7/2003. Coupling Retention Time Locked Methods and Libraries to Automated SPME or SBSE for Analysis of Flavors and Fragrances KEYWORDS AppNote 7/2003 Coupling Retention Time Locked Methods and Libraries to Automated SPME or SBSE for Analysis of Flavors and Fragrances Vanessa R. Kinton, Edward A. Pfannkoch, Jacqueline A. Whitecavage, John

More information

This document is a preview generated by EVS

This document is a preview generated by EVS INTERNATIONAL STANDARD ISO 25157 First edition 2013-04-15 Essential oil of rose, Chinese Kushui type (Rosa sertata Rosa rugosa) Huile essentielle de rose, type chinois Kushui (Rosa sertata Rosa rugosa)

More information

[ Care and Use Manual ]

[ Care and Use Manual ] Oasis HLB DISKS I. Introduction Oasis HLB is a Hydrophilic-Lipophilic-Balanced, water-wettable, reversed-phase sorbent for all your SPE needs. It is made from a specific ratio of two monomers, the hydrophilic

More information

GC/MS BATCH NUMBER: T50100

GC/MS BATCH NUMBER: T50100 GC/MS BATCH NUMBER: T50100 ESSENTIAL OIL: TURMERIC BOTANICAL NAME: CURCUMA LONGA ORIGIN: INDIA KEY CONSTITUENTS PRESENT IN THIS BATCH OF TURMERIC OIL % Ar-TURMERONE 51.2 -TURMERONE 12.1 -TURMERONE 11.8

More information

Water Injections in GC - Does Water Cause Bleed?

Water Injections in GC - Does Water Cause Bleed? Water Injections in GC - Does Water Cause Bleed? Eberhardt Kuhn Applications Chemist April 4, 2001 Practical Advice and Useful Tips for the Analysis of Semivolatile Organics by GC and GC/MS 11:00 a.m.

More information

Secrets of GC Column Dimensions

Secrets of GC Column Dimensions Secrets of GC Column Dimensions GC Columns and Consumables Simon Jones Application Engineer May 20, 2008 Slide 1 Secrets of GC Column Dimensions Do I have the right column phase? Resolution Equation Changes

More information

So Many Columns! How Do I Choose? Daron Decker Chromatography Technical Specialist

So Many Columns! How Do I Choose? Daron Decker Chromatography Technical Specialist So Many Columns! How Do I Choose? Daron Decker Chromatography Technical Specialist GC Columns Wall Coated Open Tubulars Liquid phase coated capillaries Internal Diameter 0.05 0.53mm Length 5m 100m Porous

More information

SUPELCO. Improved Performance for Cyanopropylphenyldimethylpolysiloxane (SPB-1701, SPB-1301) Capillary Columns

SUPELCO. Improved Performance for Cyanopropylphenyldimethylpolysiloxane (SPB-1701, SPB-1301) Capillary Columns Improved Performance for Cyanopropylphenyldimethylpolysiloxane (SPB-1701, SPB-1301) Capillary Columns L.M. Sidisky, Yizeng Ni, Greg Baney, Rodney George, Katherine K. Stenerson 01-0026 T401044 CFK Discussion

More information

Hans-Joachim Hubschmann. Handbook ofgc-ms. Fundamentals and Applications. Third Edition. Wl LEY-VCH. VerlagGmbH & Co. KG aa

Hans-Joachim Hubschmann. Handbook ofgc-ms. Fundamentals and Applications. Third Edition. Wl LEY-VCH. VerlagGmbH & Co. KG aa Hans-Joachim Hubschmann Handbook ofgc-ms Fundamentals and Applications Third Edition Wl LEY-VCH VerlagGmbH & Co. KG aa VII Foreword XIII Preface to the Third Edition XV 1 Introduction 1 1.1 The Historical

More information

Aroma characterization based on aromatic series analysis in table. grapes

Aroma characterization based on aromatic series analysis in table. grapes Aroma characterization based on aromatic series analysis in table grapes Yusen Wu, Shuyan Duan, Liping Zhao, Zhen Gao, Meng Luo, Shiren Song, Wenping Xu, Caixi Zhang, Chao Ma*, Shiping Wang* Department

More information

AppNote 6/2004. Thermal Desorption GC Analysis of High Boiling, High Molecular Weight Hydrocarbons SUMMARY

AppNote 6/2004. Thermal Desorption GC Analysis of High Boiling, High Molecular Weight Hydrocarbons SUMMARY AppNote 6/2004 Thermal Desorption GC Analysis of High Boiling, High Molecular Weight Hydrocarbons Edward A. Pfannkoch, Jacqueline A. Whitecavage, and Jeffrey Christenson Gerstel, Inc., 701 Digital Drive,

More information

How To Select the Correct GC Column. Simon Jones Application Engineer

How To Select the Correct GC Column. Simon Jones Application Engineer How To Select the Correct GC Column Simon Jones Application Engineer Things to Consider Is it Volatile enough to chromatograph by GC? Is it a Gas or a Liquid? How are we getting the Sample Injected? What

More information

Application Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS

Application Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS Application Note #1820230 Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS GC-MS Introduction USEPA Method 8270 [1] for semivolatiles is is used by by laboratories to measure

More information

Application Note. Author. Abstract. Introduction. Hydrocarbon Processing

Application Note. Author. Abstract. Introduction. Hydrocarbon Processing Automated Preparation of Simulated Distillation Standards and Samples for ASTM Methods D2887, D7213, D7398 and D6352 using the 7693A System with Easy SamplePrep Software Author Roger L. Firor Agilent Technologies,

More information

Determination of BTEX in Cigarette Filter Fibers Using GC-MS with Automated Calibration

Determination of BTEX in Cigarette Filter Fibers Using GC-MS with Automated Calibration Determination of BTEX in Cigarette Filter Fibers Using GC-MS with Automated Calibration Zhang Xuebin 1, Yu Chongtian 1, Liang Lina 1, Hans-Joachim Huebschmann 2, Thermo Fisher Scientific Shanghai, 1 China,

More information

Analysis of Food Samples using Thin Film Solid Phase Microextraction (TF-SPME) and Thermal Desorption GC/MS

Analysis of Food Samples using Thin Film Solid Phase Microextraction (TF-SPME) and Thermal Desorption GC/MS Analysis of Food Samples using Thin Film Solid Phase Microextraction (TF-SPME) and Thermal Desorption GC/MS Laurel Vernarelli, Jackie Whitecavage, John Stuff GERSTEL, Inc., 701 Digital Drive, Suite J,

More information

viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis

viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis [ viridis columns ] viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis Supercritical Fluid Chromatography (SFC)

More information

AppNote 3/2014. Analysis of Aroma Compounds in Edible Oils by Direct Thermal Desorption GC/MS using Slitted Microvials KEYWORDS ABSTRACT

AppNote 3/2014. Analysis of Aroma Compounds in Edible Oils by Direct Thermal Desorption GC/MS using Slitted Microvials KEYWORDS ABSTRACT AppNote 3/2014 Analysis of Aroma Compounds in Edible Oils by Direct Thermal Desorption GC/MS using Slitted Microvials Oliver Lerch Gerstel GmbH & Co. KG, Eberhard-Gerstel-Platz 1, D-45473 Mülheim an der

More information

Agilent UltiMetal Plus Stainless Steel Deactivation for Tubing, Connectors, and Fittings

Agilent UltiMetal Plus Stainless Steel Deactivation for Tubing, Connectors, and Fittings Agilent UltiMetal Plus Stainless Steel Deactivation for Tubing, Connectors, and Fittings Technical Overview Introduction Modern GC and GC/MS instruments are important analytical tools for accurate and

More information

IN QUALITATIVE ANALYSIS,

IN QUALITATIVE ANALYSIS, IN QUALITATIVE ANALYSIS, YOU VE ALWAYS HAD TO CHOOSE BETWEEN ACCURACY AND THROUGHPUT. NOW THERE S NO REASON TO ever have to. WATERS QUALITATIVE ANALYSIS solutions Waters ACQUITY UPLC System with the Waters

More information

AppNote 7/2003. Coupling Retention Time Locked Methods and Libraries to Automated SPME or SBSE for Analysis of Flavors and Fragrances

AppNote 7/2003. Coupling Retention Time Locked Methods and Libraries to Automated SPME or SBSE for Analysis of Flavors and Fragrances G L O B A L A N A L Y T I C A L S O L U T I O N S AppNote 7/2003 Coupling Retention Time Locked Methods and Libraries to Automated SPME or SBSE for Analysis of Flavors and Fragrances Vanessa R. Kinton,

More information

AppNote 4/2008. Automated Dynamic Headspace Sampling of Aqueous Samples Using Replaceable Adsorbent Traps KEYWORDS ABSTRACT

AppNote 4/2008. Automated Dynamic Headspace Sampling of Aqueous Samples Using Replaceable Adsorbent Traps KEYWORDS ABSTRACT AppNote 4/2008 Automated Dynamic Headspace Sampling of Aqueous Samples Using Replaceable Adsorbent Traps John R. Stuff, Jacqueline A. Whitecavage Gerstel, Inc., 701 Digital Drive, Suite J, Linthicum, MD

More information

Selection of a Capillary

Selection of a Capillary Selection of a Capillary GC Column - Series 3 Mark Sinnott Application Engineer March 19, 2009 Page 1 Typical Gas Chromatographic System Mol-Sieve Traps Fixed Restrictors Regulators Injection Port Detector

More information

METHOD 3600B CLEANUP

METHOD 3600B CLEANUP METHOD 3600B CLEANUP 1.0 SCOPE AND APPLICATION 1.1 Method 3600 provides general guidance on selection of cleanup methods that are appropriate for the target analytes of interest. Cleanup methods are applied

More information

The Third Dimension of Information Vol. IV Applications with the Agilent Technologies Atomic Emission Detector. O H Cl. Fe Se

The Third Dimension of Information Vol. IV Applications with the Agilent Technologies Atomic Emission Detector. O H Cl. Fe Se The Third Dimension of Information Vol. IV Applications with the Agilent Technologies Atomic Emission Detector O H Cl Sn Fe Se S Author: Bernhard Rothweiler, Agilent Technologies Deutschland GmbH Index:

More information

METHOD 3600C CLEANUP

METHOD 3600C CLEANUP METHOD 3600C CLEANUP 1.0 SCOPE AND APPLICATION 1.1 Method 3600 provides general guidance on selection of cleanup methods that are appropriate for the target analytes of interest. Cleanup methods are applied

More information

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS Thermo Scientific ConFlo IV Universal Interface Continuous Flow Interface Isotope Ratio MS 3 ConFlo IV Universal Interface for Continuous Flow Isotope Ratio MS The development of Continuous Flow carrier

More information

Slightly Polar Columns

Slightly Polar Columns 9000 Варна, ул.поп Харитон 47 e-mail : gea99@abv.bg www.geya99.com Slightly Polar Columns With the partnership of Teknokroma SLIGHTLY POLAR COLUMNS TRB-5 It is the most universal and versatile stationary

More information

High Purity Chromasolv Solvents

High Purity Chromasolv Solvents Research Chemicals High Purity Chromasolv Solvents Part of Honeywell Research Chemical s Exclusive Riedel-de Haën Brand Portfolio The Chromasolv family of solvents are used in a variety of analytical applications

More information

AppNote 3/2011. Using Three Types of Twister Phases for Stir Bar Sorptive Extraction of Whisky, Wine and Fruit Juice KEYWORDS ABSTRACT

AppNote 3/2011. Using Three Types of Twister Phases for Stir Bar Sorptive Extraction of Whisky, Wine and Fruit Juice KEYWORDS ABSTRACT AppNote 3/2011 Using Three Types of Twister Phases for Stir Bar Sorptive Extraction of Whisky, Wine and Fruit Juice Yunyun Nie, Eike Kleine-Benne Gerstel GmbH & Co. KG, Eberhard-Gerstel-Platz 1, D-45473

More information

Analysis of Terpenes in Cannabis Using the Agilent 7697A/7890B/5977B Headspace GC-MSD System

Analysis of Terpenes in Cannabis Using the Agilent 7697A/7890B/5977B Headspace GC-MSD System Analysis of Terpenes in Cannabis Using the Agilent 7697A/789B/977B Headspace GC-MSD System Faster Analysis Time = Greater Productivity Application Note Cannabis, Food Authors Ronald Honnold, Robert Kubas,

More information

Sample Preparation Method Development for Complex Matrices Such as Foods by QuEChERS and Solid Phase Extraction (SPE)

Sample Preparation Method Development for Complex Matrices Such as Foods by QuEChERS and Solid Phase Extraction (SPE) APPLICATINS Sample Preparation Method Development for Complex Matrices Such as Foods by QuEChERS and Solid Phase Extraction (SPE) Sueki Leung, Erica Pike, and Allen Misa Phenomenex, Inc., 411 Madrid Ave.,

More information

Introduction and Principles of Gas Chromatography

Introduction and Principles of Gas Chromatography Introduction and Principles of Gas Chromatography Jaap de Zeeuw Restek, Middelburg, The Netherlands Jaap.dezeeuw@restek.com Definition and Uses of Gas Chromatography GC Components and Types of Columns

More information

Appendices References...49 Glossary Equations

Appendices References...49 Glossary Equations Table of Contents List of Tables...2 List of Figures...2 Column Selection General Considerations for Column Selection... 3-11 Your Zebron Capillary GC Column... 12-29 Column Installation Pre-Installation

More information

Analysis of Fast Moving Consumer Goods (FMCG) using GCMS with static and dynamic headspace (HS)

Analysis of Fast Moving Consumer Goods (FMCG) using GCMS with static and dynamic headspace (HS) PO-CON1789E Analysis of Fast Moving Consumer Goods (FMCG) using GCMS with static and dynamic headspace (HS) ASMS 2017 TP 280 Dheeraj Handique, Ankush Bhone, Durvesh Sawant, Prashant Hase, Sanket Chiplunkar,

More information

Case 1:13-cv WBH Document Filed 12/30/16 Page 406 of 519. Exhibit 53

Case 1:13-cv WBH Document Filed 12/30/16 Page 406 of 519. Exhibit 53 Case 1:13-cv-03675-WBH Document 108-7 Filed 12/30/16 Page 406 of 519 Exhibit 53 Case 1:13-cv-03675-WBH Document 108-7 Filed 12/30/16 Page 407 of 519 JOURNAL OF GUIZHOU INSTITUTE OF TECHNOLOGY Vol. 25,

More information

DiatoSorb-W Diatomaceous Earth: Great Chromatography Millions of Years in the Making

DiatoSorb-W Diatomaceous Earth: Great Chromatography Millions of Years in the Making Restek GC DiatoSorb-W Diatomaceous Earth: Great Chromatography Millions of Years in the Making Officially listed USP SA and SNS support material. Ideal for USP and ASTM methods that use white diatomaceous

More information

a-terpinolene Ethyl butanoate 3-Carene Ethyl acetate Ethyl 2-butenoate

a-terpinolene Ethyl butanoate 3-Carene Ethyl acetate Ethyl 2-butenoate a-terpinolene Ethyl butanoate 3-Carene Ethyl acetate Ethyl 2-butenoate a-terpinene a-thujene Dimethyl sulfide Limonene b-phellandrene Myrcene p-cymen-8-ol b-caryophyllene cis-3-hexene-1-ol hexadecyl acetate

More information

Application Note 116 Monitoring VOCs in Ambient Air Using Sorbent Tubes with Analysis by TD-GC/MS in Accordance with Chinese EPA Method HJ

Application Note 116 Monitoring VOCs in Ambient Air Using Sorbent Tubes with Analysis by TD-GC/MS in Accordance with Chinese EPA Method HJ Application Note Monitoring VOCs in Ambient Air Using Sorbent Tubes with Analysis by TD-GC/MS in Accordance with Chinese EPA Method HJ -3 Application Note Abstract This application note demonstrates the

More information

EPA Test Methods for GC

EPA Test Methods for GC EPA Test Methods for GC Method # Description 0016B Total Reduced Sulfur - (GC Analysis) 0018 VOC - GC 0311 HAPS in Paints & Coatings - Direct Injection GC 0312A Residual Styrene in SBR Latex by GC 0312B

More information