Fast, Accurate Environmental Testing

Size: px
Start display at page:

Download "Fast, Accurate Environmental Testing"

Transcription

1 GC Columns Fast, Accurate Environmental Testing Using Zebron GC Columns Featuring Pesticides Diesel Range Organics Semivolatiles Dioxane And more..

2 Semi-Volatile Organic Compounds 37 Analytes in 6 mins min App ID 058 Column: Zebron ZB-SemiVolatiles Dimensions: 30 meter x 0.5 mm x 0.5 µm Part No.: 7HG-G07- Injection: Split 80 C, µl Recommended Liner: Zebron PLUS Single Taper with Wool, 4 mm ID Liner Part No.: AG-0A-05 (for Agilent Systems) Septum: AG (PhenoRed -400) Inlet Seal: AG0-860 (Easy Seals ) Carrier Gas: ml/min (constant flow) Oven Program: 40 C for 0.5 min to C/ min to 95 6 C/min to 35 5 C/min for min Detector: 340 C; amu Sample: Analytes are 5 ppm in dichloromethane See entire analyte list and technical note at TN-039 Bases, Acids, and Neutrals by GC-MS Standard Curve at 5 µg/ml min Waste Water Matrix Extraction Rapid and accurate chromatography App ID 3075 App ID min Column: Zebron ZB-SemiVolatiles Dimensions: 30 meter x 0.5 mm x 0.5 µm Part No.: 7HG-G07- Injection: 50 C, µl Recommended Liner: Zebron PLUS Single Taper with Wool, 4 mm ID Liner Part No.: AG-0A-05 (for Agilent Systems) Septum: AG (PhenoRed-400) Inlet Seal: AG0-860 (Easy Seals) Carrier Gas: ml/min (constant flow) Oven Program: 40 C for 0.66 min to C/min to 95 6 C/min to 35 5 C/min for min Detector: 300 C; amu Phenomenex l WEB:

3 Chlorinated Pesticides using Hydrogen A) Zebron ZB-CLPesticides App ID min B) Zebron ZB-CLPesticides App ID min Column: As listed Dimensions: A) 30 meter x 0.3 mm x 0.3 µm B) 30 meter x 0.3 mm x 0.5 µm Part No.: A) 7HM-G08-5 B) 7HM-G09- Injection: 50 C, µl Recommended Liner: Zebron PLUS Single Taper with Wool, 4 mm ID Liner Part No.: AG-0A-05 (for Agilent Systems) Septum: AG (PhenoRed -400) Inlet Seal: AG0-860 (Easy Seals ) Carrier Gas: 3.5 ml/min (constant flow) Oven Program: 85 C for 0.5 min to C/min for 3 min to C/min Detector: 330 C Sample: Analytes are 00 ng/ml in hexane.,4,5,6-tcmx (Surr). a-bhc 3. g-bhc 4. b-bhc 5. d-bhc 6. Heptachlor 7. Aldrin 8. Heptachlor epoxide 9. trans-chlordane 0. cis-chlordane. Endosulfan I. 4,4 -DDE 3. Dieldrin 4. Endrin 5. 4,4 -DDD 6. Endosulfan II 7. 4,4 -DDT 8. Endrin aldehyde 9. Methoxychlor 0. Endosulfan sulfate. Endrin ketone. Decachlorobiphenyl (Surr),4-Dioxane by GC-MS Tap Water Extracted Ion Chromatogram at 5 ng/ml App App ID ID Column: Zebron ZB-64 Dimensions: 30 meter x 0.5 mm x.4 µm Part No.: 7HG-G005-7 Guard Column: 5 m Z-Guard (7AG-G GZ0) Injection: 00 C (hold 0.5 min),.0 µl Recommended Liner: Zebron PLUS Single Taper Z-Liner, 4 mm ID Liner Part No.: AG-0A3-05 (for Agilent Systems) Septum: AG (PhenoRed-400) Inlet Seal: AG0-860 (Easy Seals) Phenomenex l WEB: Carrier Gas: ml/min (constant flow) Oven Program: 30 C for min to 90 0 C/min to C/min Detector: 50 C Sample:. THF-d8.,4-dioxane-d8 3.,4-dioxane

4 Multi-Residue Pesticides by GC-MS , , , min ,95 77, min 4 min App ID 684 Column: Zebron ZB-MultiResidue - Dimensions: 30 meter x 0.5 mm x 0.5 µm Part No.: 7HG-G06- Injection: 60 C, µl Recommended Liner: Zebron PLUS Single Taper with Wool, 4 mm ID Liner Part No.: AG-0A-05 (for Agilent Systems) Septum: AG (PhenoRed -400) Inlet Seal: AG0-860 (Easy Seals ) Carrier Gas: 0.9 ml/min (constant flow) Oven Program: 80 C for 0.5 min to 50 0 C/ min to 40 4 C/min to 30 5 C/min for 3 min Detector: 30 C; amu Sample: Analytes are ppm in dichloromethane See entire analyte list and technical note at TN-0 Diesel Range Organics (DROs) by GC Diesel Fuel Hydrocarbons Zebron ZB-5HT Inferno Zebron ZB-HT Inferno App ID 647 App ID min min Column: Zebron ZB-5HT Inferno Dimensions: 5 meter x 0.3 mm x 0.0 μm Part No.: 7EM-G05-0 Injection: 63 C, 0. μl Carrier Gas: ml/min (constant flow) Oven Program : 60 C to 375 C at 5 C/min ZB-HT Inferno 5 meter x 0.3 mm x 0.5 μm 7EM-G C, 0 μl Detector: 400 C 330 C Sample: Diesel Fuel was 00 ppm in Dichloromethane with Internal Standards at 50 ppm. Decane. Tetracontane ml/min (constant flow) 50 C for min to C/min for 5 min Recommended Liner: Zebron PLUS Single Taper, 4 mm ID Liner Part No.: AG-0A0-05 Septum: AG (PhenoRed-400) Inlet Seal: AG0-860 (Easy Seals) Phenomenex l WEB:

5 Select the GC Column for your Environmental Methods Please contact your Phenomenex representative for additional products and assistance. Essentials Inferno Plus Unlimited Drinking Water Trihalomethanes by GC/MS with Selected Ion Monitoring (SIM) Volatile Halogenated Organics by Purge & Trap GC/PID/ELCD Volatile Aromatics and Unsaturated Organics by Purge & Trap GC,-Dibromoethane (EDB),,-Dibromo-3-chloropropane (DBCP), and,,3-trichloropropane (3TCP) by GC Organohalide Pesticides & Aroclors by GC/ECD Nitrogen & Phosphorus Containing Pesticides by GC/NPD Chlorinated Pesticides by GC/ECD Ethylene Thiourea (ETU) by GC/NPD, 3, 7, 8-Tetrachlorodibenzo-p-dioxin by GC/HRMS Chlorinated Acids by Liquid-Liquid Extraction, Derivatization and GC/ECD Nitrosamines by Solid Phase Extraction (SPE) and GC/MS/MS with Large Volume injection,4-dioxane by Solid Phase Extraction (SPE) and GC/MS with Selected Ion Monitoring (SIM) Triazine Pesticides and their Degradates by GC/MS Purgeable Organic Compounds by GC/MS Semi-volatile Organic Chemicals by Solid Phase Extraction (SPE) and GC/MS Phenols by Solid Phase Extraction (SPE) and GC/MS Explosives and Related Compounds by Solid Phase Extraction (SPE) and GC/MS Endothall by Aqueous Derivatization, Liquid-Solid Extraction, and GC/ECD Chlorinated Solvents & Disinfection Byproducts by Liquid-Liquid Extraction and GC/ECD Haloacetic Acids and Dalapon by Liquid-Liquid Extraction, Derivatization, and GC/ECD Carbonyl Compounds by Pentafluorobenzylhydroxylamine Derivatization and GC/ECD Waste Water Purgeable Halocarbons by Purge & Trap GC Purgeable Aromatics by Purge & Trap GC Acrolein & Acrylonitrile Purge & Trap GC Phenols by GC/ECD Phthalate Esters by GC/ECD Nitrosamines by GC/NPD Organochlorine Pesticides and PCBs by GC/ECD Nitroaromatics & Isophorone by GC/FID and GC/ECD Polynuclear Aromatic Hydrocarbons by GC/FID Haloethers by GC/ECD,3,7,8-Tetrachlorodibenzo-p-dioxin by GC/MS Chlorinated Herbicides by GC/ECD Triazine Herbicides by GC/MS Organophosphorus Pesticides by GC/MS Purgeable Volatiles by Purge & Trap GC/MS Base/Neutral and Acids by GC/MS Tetra- through Octa-Chlorinated Dioxins and Furans by Isotope Dilution HRGC/HRMS Polybrominated Diphenyl Esters (PBDEs) by HRGC/HRMS Organohalide Pesticides, Organophosphorus Pesticides, and Phenoxy-Acid Herbicides by GC Volatile Organic Compounds by Isotope Dilution GC/MS Semi-volatile Organic Compounds by Isotope Dilution GC/MS Organophosphorous Pesticides by GC/FPD Phenoxy-Acid Herbicides by GC/ECD Dazomet by GC/NPD Pharmaceutical Volatile Organic Compounds by Purge & Trap GC or Isotope Dilution GC/MS Polychlorinated Biphenyl (PCB) Congeners by HRGC/HRMS Pharmaceutical Manufacturing Volatile Organic Compounds by GC/FID ZB-64 ZB-50 ZB-WAX ZB-5HT ZB-plus ZB-5plus ZB-WAXplus ZB-CLPesticides - & ZB-MultiResidue - & ZB-SemiVolatiles Solid Waste Halogenated Volatile Organics by GC/ELCD Nonhalogenated Organics by GC Aromatic Volatile Organics by GC/PID Aromatic and Halogenated Volatiles by GC/PID or GC/ELCD Acrolein and Acrylonitrile by GC/FID Acrylamide by GC/ECD Phenols by GC/ECD or GC/FID Phthalate Esters by GC/ECD Organochlorine Pesticides by GC/ECD Polychlorinated Biphenyls (PCBs) by GC/ECD Nitroaromatics and Cyclic Ketones by GC/ECD or GC/NPD Explosives by GC/ECD Polynuclear Aromatic Hydrocarbons by GC/FID Chlorinated Hydrocarbons by GC/ECD Aniline and Selected Derivatives by GC/NPD Organophosphorus Pesticides by GC/FPD or GC/NPD Chlorinated Herbicides by GC/ECD Volatile Organic Compounds by GC/MS Semi-volatile Organic Compounds by GC/MS Polynuclear Aromatic Hydrocarbons (PAHs ) by SPME and GC/MS with Selected Ion Monitoring (SIM) Polychlorinated Dibenzo-P-Dioxins (PCDDs) and Polychlorinated Dibenzofurans (PCDFs) By HRGC/LRMS Polychlorinated Dibenzo-P-Dioxins (PCDDs) and Polychlorinated Dibenzofurans (PCDFs) By HRGC/LRMS Semi-Volatile Organic Compounds by GC/FT-IR Bis(-chloroethyl) Ether and Hydrolysis Products by Direct Aqueous Injection GC/FT-IR Phenomenex l WEB:

6 Ordering Information Zebron ZB-SemiVolatiles GC Columns ZB-SemiVolatiles GC Columns to 35/350 7EG-G to 35/350 7EG-G to 35/350 7FD-G to 35/350 7FD-G to 35/350 7HG-G to 35/350 7HG-G to 35/350 7KG-G07- Zebron ZB-HT Inferno GC Columns to 400/430 7AK-G to 400/430 7CM-G to 400/430 7EG-G to 400/430 7EG-G to 400/430 7EM-G to 400/430 7EM-G to 400 7EK-G to 400/430 7FD-G to 400/430 7HG-G to 400/430 7HG-G to 400/430 7HM-G to 400/430 7HM-G to 400 7HK-G04-05 Zebron ZB-5HT Inferno GC Columns to 400/430 7EG-G to 400/430 7EG-G to 400/430 7EM-G to 400/430 7EM-G to 400 7EK-G to 400/430 7FD-G to 400/430 7HG-G to 400/430 7HG-G to 400/430 7HM-G to 400/430 7HM-G to 400 7HK-G to 400/430 7KG-G05- Note: If you need a 5 in. cage, simply add a (-B) after the part number, e.g., 7HG-G05--B. Some exceptions may apply. Agilent 6850 and some SRI and process GC systems use only 5 in. cages.

7 Ordering Information Zebron ZB-CLPesticides GC Columns ZB-CLPesticides- GC Columns to 30/340 7HG-G to 30/340 7HM-G to 30/340 7HM-G to 30/340 7HK-G08-7 ZB-CLPesticides- GC Columns to 30/340 7HG-G to 30/340 7HM-G to 30/340 7HM-G to 30/340 7HK-G09-6 Zebron ZB-MultiResidue GC Columns ZB-MultiResidue- GC Columns to 30/340 7FD-G to 30/340 7HG-G to 30/340 7HM-G to 30/340 7HM-G to 30/340 7HK-G06-7 ZB-MultiResidue- GC Columns to 30/340 7HG-G to 30/340 7HM-G to 30/340 7HK-G07-7 Zebron ZB-64 GC Columns to 60 7FD-G to 60 7HG-G to 60 7HM-G to 60 7HK-G to 60 7KG-G to 60 7KM-G to 60 7KK-G to 60 7LK-G to 60 7NK-G Note: If you need a 5 in. cage, simply add a (-B) after the part number, e.g., 7HG-G005-7-B. Some exceptions may apply. Agilent 6850 and some SRI and process GC systems use only 5 in. cages. If Zebron columns do not provide you with equivalent or better separations as compared to any other GC column of the same phase and comparable dimensions, send in your comparative data within 45 days and keep the column for FREE! More GC columns, kits, and accessories available at

8 GC Columns Fast, Accurate Environmental Testing Using Zebron GC Columns Australia t: +6 (0) f: +6 (0) Austria t: +43 (0) f: +43 (0) Belgium t: +3 (0) (French) t: +3 (0) (Dutch) f: +3 (0) beinfo@phenomenex.com Canada t: + (800) f: + (30) info@phenomenex.com China t: f: +86 (0) phen@agela.com Denmark t: f: nordicinfo@phenomenex.com Finland t: +358 (0) f: nordicinfo@phenomenex.com France t: +33 (0) f: +33 (0) franceinfo@phenomenex.com Germany t: +49 (0) f: +49 (0) anfrage@phenomenex.com India t: +9 (0) f: +9 (0) indiainfo@phenomenex.com Ireland t: +353 (0) f: eireinfo@phenomenex.com Luxembourg t: +3 (0) f: +3 (0) nlinfo@phenomenex.com Mexico t: f: tecnicomx@phenomenex.com The Netherlands t: +3 (0) f: +3 (0) nlinfo@phenomenex.com New Zealand t: +64 (0) f: +64 (0) nzinfo@phenomenex.com Norway t: f: nordicinfo@phenomenex.com Puerto Rico t: + (800) 54-HPLC f: + (30) info@phenomenex.com Spain t: f: espinfo@phenomenex.com Sweden t: +46 (0) f: nordicinfo@phenomenex.com United Kingdom t: +44 (0) f: +44 (0) ukinfo@phenomenex.com USA t: + (30) f: + (30) info@phenomenex.com All other countries Corporate Office USA t: + (30) f: + (30) info@phenomenex.com Italy t: f: italiainfo@phenomenex.com Phenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department at international@phenomenex.com BR497707_I Terms and Conditions Subject to Phenomenex standard terms & conditions, which may be viewed at Trademarks Inferno, MultiResidue, Z-Liner, EasySeals, PhenoRed, plus, 5plus, WAXplus, Z-Guard, and Zebron are trademarks of Phenomenex. Agilent is a registered trademark of Agilent Technologies, Inc. 07 Phenomenex, Inc. All rights reserved.

Accurate, Reproducible Results for Environmental Methods with Zebron GC Columns

Accurate, Reproducible Results for Environmental Methods with Zebron GC Columns Accurate, Reproducible Results for Environmental Methods with Zebron GC Columns BUY NOW AND SAVE! Length Sale Price* 10-15 meter $ 199 30 meter $ 399 60 meter $ 599 *Offer valid only for addressee, limit

More information

The BIG GC Special. Details, Playoff Specials, and Early Bird Discounts Inside! Expires: December 20, 2013 Mention Offer Code: ZBNF1213.

The BIG GC Special. Details, Playoff Specials, and Early Bird Discounts Inside! Expires: December 20, 2013 Mention Offer Code: ZBNF1213. The BIG GC Special Details, Playoff Specials, and Early Bird Discounts Inside! Exclusive Savings on Zebron GC Columns for any phase new to your company* Length 10-15 Meter 30 Meter 60 Meter Sale Price

More information

EPA Test Methods for GC

EPA Test Methods for GC EPA Test Methods for GC Method # Description 0016B Total Reduced Sulfur - (GC Analysis) 0018 VOC - GC 0311 HAPS in Paints & Coatings - Direct Injection GC 0312A Residual Styrene in SBR Latex by GC 0312B

More information

Take Your Food Testing to the Next Level

Take Your Food Testing to the Next Level GC Columns Take Your Food Testing to the Next Level Using Zebron GC Columns Featuring Pesticides FAMEs Essential Oils Flavors And more.. www.phenomenex.com/foodgc Pesticide Screening by GC-MS - 7 7 9,9

More information

4. Place a 20 ml VOA vial in position 1 of the tray. 5. Place a 6 ml C18-E cartridge in position 1 of the carousel.

4. Place a 20 ml VOA vial in position 1 of the tray. 5. Place a 6 ml C18-E cartridge in position 1 of the carousel. Increase Throughput and Recoveries for EPA Method 508.1 with Automated Extraction using Strata C18-E SPE Cartridges and Zebron ZB-MultiResidue GC Columns Kali Tudela Phenomenex, Inc., 411 Madrid Ave.,

More information

AGGREGATE ANALYSIS. Biologics Workflow. by Size Exclusion Chromatography

AGGREGATE ANALYSIS. Biologics Workflow. by Size Exclusion Chromatography Biologics Workflow AGGREGATE ANALYSIS by Size Exclusion Chromatography New biozen SEC columns provide: High efficiency on both HPLC and UHPLC Extreme inertness and robustness Finely tuned high and low

More information

New ZB-5HT Inferno The World s Highest Temperature Non-Metal GC Column

New ZB-5HT Inferno The World s Highest Temperature Non-Metal GC Column New ZB-5HT Inferno The World s Highest Temperature Non-Metal GC Column The World's First Non-metal 5% Phenyl Phase GC Column Rated to 430 C * Specially processed for thermal stability up to 430 C A true

More information

Analysis. Priority LC GC. Zebron PAH Accurately quantitate EU and EPA PAHs in less than 28 minutes

Analysis. Priority LC GC. Zebron PAH Accurately quantitate EU and EPA PAHs in less than 28 minutes Priority Analysis LC GC Core-Shell Technology GC Columns Kinetex PAH Expanded resolution with chemical selectivity specifically for PAHs Increased throughput and sensitivity with core-shell technology

More information

Evaluating CLP and EPA Methods for Pesticides in Water Using Agilent J&W DB-CLP1/DB-CLP2 GC Columns

Evaluating CLP and EPA Methods for Pesticides in Water Using Agilent J&W DB-CLP1/DB-CLP2 GC Columns Evaluating CLP and EPA Methods for Pesticides in Water Using Agilent J&W DB-CLP/DB-CLP GC Columns Application Note Environmental Authors Doris Smith and Ken Lynam Agilent Technologies, Inc. Abstract The

More information

Rtx -CLPesticides Columns Reduce Analysis Time; Reduce System Maintenance

Rtx -CLPesticides Columns Reduce Analysis Time; Reduce System Maintenance Columns Reduce Analysis Time; Reduce System Maintenance 0 YEARS Turning Visions into Reality www.restek.com 00-- --00 and Fused Silica Columns Detect and confirm 0 common organochlorine pesticides simultaneously.

More information

Your Reversed Phase Method

Your Reversed Phase Method PLC Columns for Your Reversed Phase Method Balanced Non-Polar & Polar Selectivity Strong Non-Polar & Polar Selectivity Strong Polar & Aromatic Selectivity Unique Isomeric & alogenated Selectivity Robust

More information

APPLICATIONS TN Peptide Purification Method Development: Application for the Purification of Bivalirudin. Introduction

APPLICATIONS TN Peptide Purification Method Development: Application for the Purification of Bivalirudin. Introduction Peptide Purification Method Development: Application for the Purification of Bivalirudin Marc Jacob, Joshua Heng, and Tivadar Farkas Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 91 USA In this technical

More information

Quick and Simple Cleanup for. Medicinal Chemistry. It s BIG.

Quick and Simple Cleanup for. Medicinal Chemistry. It s BIG. Quick and Simple Cleanup for Medicinal It s IG. Guaranteed Cleanup of Post Synthesis Reactions Strata -XL Giga s are designed to make Medicinal easy! With Strata Giga tubes I ve been able to purify a compound

More information

Gemini-NX Performance paired with Axia Technology

Gemini-NX Performance paired with Axia Technology Si Si Si Si Si Si Si C Si Si Si Si Si Gemini-NX Performance paired with Axia Technology Gemini -NX Axia Packed Technology Improves Yield, Throughput, and Column Lifetime Ideal Purification Platform While

More information

Multi-residue Analysis for PAHs, PCBs and OCPs on Agilent J&W FactorFour VF-Xms

Multi-residue Analysis for PAHs, PCBs and OCPs on Agilent J&W FactorFour VF-Xms Multi-residue Analysis for PAHs, PCBs and OCPs on Agilent J&W FactorFour VF-Xms Application Note Author Laura Provoost Agilent Technologies, Inc. Introduction In multi-residue analysis different groups

More information

METHOD 3600C CLEANUP

METHOD 3600C CLEANUP METHOD 3600C CLEANUP 1.0 SCOPE AND APPLICATION 1.1 Method 3600 provides general guidance on selection of cleanup methods that are appropriate for the target analytes of interest. Cleanup methods are applied

More information

APPLICATIONS TN Separation and Quantitation of Physiologic Cobalamins (Vitamin B 12

APPLICATIONS TN Separation and Quantitation of Physiologic Cobalamins (Vitamin B 12 APPLICATIONS Separation and Quantitation of Physiologic Cobalamins (Vitamin B 12 in Dietary Supplements by LC/MS/MS using Synergi Fusion-RP Column Xianrong (Jenny Wei Senior Scientist PhenoLogix applications

More information

Experience the Zebron Difference

Experience the Zebron Difference Experience the Zebron Difference Premier GC Column Selection Guide www.phenomenex.com/gc Introducing the Zebron Experience Proven Performance Zebron GC columns are engineered by expert Phenomenex GC scientists

More information

Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor

Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor Application Note Pesticides Authors Charlie Spanjers and Paul Dauenhauer University of Minnesota, Twin Cities

More information

Organochlorine Pesticides by GCxGC-ECD

Organochlorine Pesticides by GCxGC-ECD Organochlorine Pesticides by GCxGC-ECD LECO Corporation; Saint Joseph, Michigan USA Key Words: GCxGC-ECD, Environmental, Quantification 1. Introduction United States Environmental Protection Agency Method

More information

D2245

D2245 GC Columns and Accessories Thermo Scientific Chromatography Columns and Consumables 2014-2015 GC Column Selection by ASTM Method Selected ASTM methods are listed below with the appropriate Thermo Scientific

More information

APPLICATIONS TN Lux Cellulose-2 or -4 Cellulose tris (3-chloro-4-methylphenylcarbamate) or (4-chloro-3-methylphenylcarbamate)

APPLICATIONS TN Lux Cellulose-2 or -4 Cellulose tris (3-chloro-4-methylphenylcarbamate) or (4-chloro-3-methylphenylcarbamate) T-1079 APPLICATI Method Development for Reversed Phase Chiral LC/M/M Analysis of tereoisomeric Pharmaceutical Compounds with Polysaccharide-based tationary Phases Philip J. Koerner, Kari Carlson, Liming

More information

Fast and Accurate Analysis of PBDEs in a Single Run, Including

Fast and Accurate Analysis of PBDEs in a Single Run, Including Fast and Accurate Analysis of PBDEs in a Single Run, Including Kory Kelly, Adam Endeman, and Matthew Trass Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 90501 USA PO14700713_2 PO14400613_W_2 Abstract

More information

APPLICATIONS TN HPLC Conditions. Lux Cellulose-1 Cellulose tris(3,5-dimethylphenylcarbamate)

APPLICATIONS TN HPLC Conditions. Lux Cellulose-1 Cellulose tris(3,5-dimethylphenylcarbamate) T-147 APPLICATIS Alternative Selectivity of Chiral Stationary Phases Based on Cellulose tris(3-chloro-4-methylphenylcarbamate) and Cellulose tris(3,5-dimethylphenylcarbamate) Liming Peng, Tivadar Farkas

More information

3 Ways To Choose. All GC 5 Phases Are Not The Same! ZB-5. ZB-5MSi. ZB-5HT Inferno. ZB-5ms ZB-5MSPLUS. ZB-SemiVolatiles.

3 Ways To Choose. All GC 5 Phases Are Not The Same! ZB-5. ZB-5MSi. ZB-5HT Inferno. ZB-5ms ZB-5MSPLUS. ZB-SemiVolatiles. 3 Ways To Choose All GC 5 Phases Are Not The Same! ZB-5 ZB-5M ZB-5HT Inferno ZB-5ms ZB-5MSPLUS ZB-SemiVolatiles www.phenomenex.com/5phase Choosing Your 5 Phase Is Easy Use the NEW GC Column Finder web

More information

Introduction to Gas Chromatography

Introduction to Gas Chromatography Introduction to Gas Chromatography 31-1 Objectives To know what is chromatography To understand the mechanism of compound separation To know the basic of gas chromatography system 31-2 Chromatography Definition

More information

Determination of Organochlorine Pesticides and Polychlorinated Biphenyls Using GC/MS/MS Operated in the MRM Mode

Determination of Organochlorine Pesticides and Polychlorinated Biphenyls Using GC/MS/MS Operated in the MRM Mode PO-CON1610E Determination of Organochlorine Pesticides and Polychlorinated Biphenyls Using GC/MS/MS Operated in the MRM Mode Pittcon 2016 1110-2 Brahm Prakash, William Lipps, Di Wang, Shilpi Chopra, Nicole

More information

Fast and Accurate Analysis of PBDEs in a Single Run, Including BDE-209

Fast and Accurate Analysis of PBDEs in a Single Run, Including BDE-209 Fast and Accurate Analysis of PBDEs in a Single Run, Including Kory Kelly, Xianrong (Jenny) Wei, and Matthew Trass Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 90501 USA PO16570913_W_2 PO14400613_W_2

More information

METHOD 3600B CLEANUP

METHOD 3600B CLEANUP METHOD 3600B CLEANUP 1.0 SCOPE AND APPLICATION 1.1 Method 3600 provides general guidance on selection of cleanup methods that are appropriate for the target analytes of interest. Cleanup methods are applied

More information

APPLICATIONS TN Increased Capabilities for the Analysis of Hormones in Drinking and Waste Water Using Solid Phase Extraction (SPE) and LC/MS/MS

APPLICATIONS TN Increased Capabilities for the Analysis of Hormones in Drinking and Waste Water Using Solid Phase Extraction (SPE) and LC/MS/MS Increased Capabilities for the Analysis of Hormones in Drinking and Waste Water Using Solid Phase Extraction (SPE) and LC/MS/MS Xianrong (Jenny) Wei Senior Scientist Jenny is a Senior Scientist in Phenomenex

More information

SUPELCO. Improved Performance for Cyanopropylphenyldimethylpolysiloxane (SPB-1701, SPB-1301) Capillary Columns

SUPELCO. Improved Performance for Cyanopropylphenyldimethylpolysiloxane (SPB-1701, SPB-1301) Capillary Columns Improved Performance for Cyanopropylphenyldimethylpolysiloxane (SPB-1701, SPB-1301) Capillary Columns L.M. Sidisky, Yizeng Ni, Greg Baney, Rodney George, Katherine K. Stenerson 01-0026 T401044 CFK Discussion

More information

Yokogawa Analytical Systems Inc., Nakacho, Musashino-shi, Tokyo , Japan.

Yokogawa Analytical Systems Inc., Nakacho, Musashino-shi, Tokyo , Japan. Determination of organochlorine pesticides in river water by gas chromatography-negative-ion chemical-ionization mass spectrometry using large volume injection Sadao Nakamura,* Takashi Yamagami and Shigeki

More information

New Application Specific Columns for Semi-volatile and ECD Methods Lead the Way to Higher Productivity in Environmental Laboratories

New Application Specific Columns for Semi-volatile and ECD Methods Lead the Way to Higher Productivity in Environmental Laboratories New Application Specific Columns for Semi-volatile and ECD Methods Lead the Way to Higher Productivity in Environmental Laboratories Ken Lynam CSD Application Chemist Presentation Outline DB-UI 8270D columns

More information

The Standard for ph Method Development

The Standard for ph Method Development The Standard for ph Method Development High Efficiency Excellent Lifetime ph Stable - www.phenomenex.com/gemini U.S. Patent No.,, Setting the Standard for ph Method Development Gemini columns are rugged

More information

Non-Potable Water A2LA Certificate

Non-Potable Water A2LA Certificate COLOR Color Biochemical Oxygen Demand (BOD); Carbonaceous DEMAND BOD; Chemical Oxygen Demand (COD); Total Organic Carbon (TOC) HEXAVALENT CHROMIUM INORGANIC NUTRIENTS LOW-LEVEL MERCURY METALS I & II METALS

More information

U.S. EPA Method 8270 for multicomponent analyte determination

U.S. EPA Method 8270 for multicomponent analyte determination ENVIRONMENTAL application note U.S. EPA Method 8270 for multicomponent analyte determination Elaine A. LeMoine and Herman Hoberecht Introduction Multicomponent analytes are compounds that yield several

More information

APPLICATIONS TN Detection of Environmental Contaminants Caused by the Oil Spill in the Gulf of Mexico by GC and HPLC

APPLICATIONS TN Detection of Environmental Contaminants Caused by the Oil Spill in the Gulf of Mexico by GC and HPLC Detection of Environmental Contaminants Caused by the Oil Spill in the Gulf of Mexico by GC and HPLC Sky Countryman, Ngoc Nguyen, Jeff Layne, Kory Kelly, and Zeshan Aqeel Phenomenex, Inc., 411 Madrid Ave.,

More information

ApplicationNOTE ULTRA TRACE ANALYSIS OF DIOXINS AND FURANS IN HUMAN ADIPOSE TISSUE USING SFE-LC EXTRACTION/CLEANUP AND THE WATERS AUTOSPEC ULTIMA NT

ApplicationNOTE ULTRA TRACE ANALYSIS OF DIOXINS AND FURANS IN HUMAN ADIPOSE TISSUE USING SFE-LC EXTRACTION/CLEANUP AND THE WATERS AUTOSPEC ULTIMA NT Introduction Legislative limits for dioxins and furans are ever decreasing 1, providing a greater challenge for the dioxin analyst. The extraction and clean-up processes used by the analyst can be imperative

More information

environmental Rtx -CLPesticides and Rtx -CLPesticides2 Columns: The Ideal Confirmational Pair for Analyzing Polychlorinated Biphenyls (PCBs)

environmental Rtx -CLPesticides and Rtx -CLPesticides2 Columns: The Ideal Confirmational Pair for Analyzing Polychlorinated Biphenyls (PCBs) environmental #59120 Applications note Rtx -CLPesticides and Rtx -CLPesticides2 Columns: The Ideal Confirmational Pair for Analyzing Polychlorinated Biphenyls (PCBs) Polychlorinated biphenyls (PCBs) are

More information

Agilent J&W GC Column Selection Guide SPEED YOUR SELECTION WITH THIS ONE-STOP RESOURCE

Agilent J&W GC Column Selection Guide SPEED YOUR SELECTION WITH THIS ONE-STOP RESOURCE Agilent J&W GC Column Selection Guide SPEED YOUR SELECTION WITH THIS ONE-STOP RESOURCE Table of Contents The story behind Agilent J&W Advanced GC Columns... 1 Column Selection Principles... 3 Selecting

More information

6-24 hours e. Coliform, Fecal and Total W, DW P,G Cool, 4 C, 0.008% Na 2 S 2 O 3. Fecal Streptococci W P,G Cool, 4 C, 0.

6-24 hours e. Coliform, Fecal and Total W, DW P,G Cool, 4 C, 0.008% Na 2 S 2 O 3. Fecal Streptococci W P,G Cool, 4 C, 0. Coliform, Colilert, P, Bottle or Bag Cool, 4 C, 0.008% Na 2 S 2 O 3 d Coliform, Fecal and Total, P,G Cool, 4 C, 0.008% Na 2 S 2 O 3 d Fecal Streptococci P,G Cool, 4 C, 0.008% Na 2 S 2 O 3 d INORGANIC TESTS

More information

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling Andrea Caruso and Massimo Santoro, Thermo Fisher Scientific, Milan, Italy Application Note 1316 Key

More information

USP <467> Headspace Residual Solvent Assay with a HT3 Headspace Instrument

USP <467> Headspace Residual Solvent Assay with a HT3 Headspace Instrument Application Note Abstract The US Pharmacopeia recently released USP as the current monograph for determining residual solvents in pharmaceutical products by static headspace. The USP classified these

More information

CHAPTER FOUR ORGANIC ANALYTES

CHAPTER FOUR ORGANIC ANALYTES CHAPTER FOUR ORGANIC ANALYTES allowed flexibility in the choice of apparatus, reagents, and supplies. In addition, unless specified in a regulation, the use of SW-846 methods is not mandatory in response

More information

ApplicationNOTE A STUDY OF THE ANALYSIS OF POLYBROMINATED DIPHENYL ETHER FLAME RETARDANTS BY GC/MS/MS. Introduction. Materials and Methods

ApplicationNOTE A STUDY OF THE ANALYSIS OF POLYBROMINATED DIPHENYL ETHER FLAME RETARDANTS BY GC/MS/MS. Introduction. Materials and Methods Abstract The development of a GC/MS/MS method for the analysis of brominated flame retardants will be presented. Standard methods require the use of high resolution magnetic sector instrumentation, which

More information

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil Che Jinshui, 1 Deng Guifeng, 1 Liang Lina, 1 and Aaron Kettle, 2 1 Thermo Fisher Scientific (China)

More information

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL DATE

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL DATE of 3 The required detection limit is generally that of the approved method's detection limit and a value less than the regulatory limit for the analyte. For the Drinking Water Category, the Program has

More information

GC COLUMN GUIDE. Powerful Gas Chromatography and Chromatography Data System Solutions

GC COLUMN GUIDE. Powerful Gas Chromatography and Chromatography Data System Solutions COLUMN GUE Powerful Gas Chromatography and Chromatography Data System Solutions Column Reference Guide Column Reference guide by phase SCION Column Phase Composition/Porous Layer Application SCION-1MS

More information

DETERMINATION OF OCs, PCBs AND SYNTHETIC PYRETHROIDS IN ANIMAL FAT

DETERMINATION OF OCs, PCBs AND SYNTHETIC PYRETHROIDS IN ANIMAL FAT DETERMINATION OF OCs, PCBs AND SYNTHETIC PYRETHROIDS IN ANIMAL FAT Peter Hancock 1, Mike Hetmanski 2 and Richard J. Fussell 2 1 Waters Corporation, Atlas Park, Simonsway, Manchester M22 5PP, UK 2 Central

More information

Developing Large Volume Injection (LVI) in Split / Splitless Inlets. Philip J. Koerner Phenomenex Inc. NEMC 2014

Developing Large Volume Injection (LVI) in Split / Splitless Inlets. Philip J. Koerner Phenomenex Inc. NEMC 2014 Developing Large Volume Injection (LVI) in Split / Splitless Inlets Philip J. Koerner Phenomenex Inc. NEMC 2014 Goal To produce a method that provides the largest response of analytes that will produce

More information

OREGON Environmental Laboratory Accreditation Program ORELAP Fields of Accreditation ALS Environmental - Simi Valley

OREGON Environmental Laboratory Accreditation Program ORELAP Fields of Accreditation ALS Environmental - Simi Valley MATRIX Reference Code Analyte Code Description ASTM C471M- 14 2014 ASTM D5504-12 2012 3964 Orthorhombic Cyclooctasulfur 4842 1-Propanethiol 6113 2,5-Dimethylthiophene 4544 2-Ethylthiophene 4843 2-Propanethiol

More information

Trim Time Not Columns Multiresidue Pesticides Analysis with an Intuvo GC/TQ

Trim Time Not Columns Multiresidue Pesticides Analysis with an Intuvo GC/TQ Trim Time Not Columns Multiresidue Pesticides Analysis with an Intuvo GC/TQ Courtney Milner, Ph.D. Agilent Technologies Santa Clara, CA ASMS 2018 VIP Session 1 Agenda Pesticide analysis trends Targeted

More information

KSA Environmental Laboratory Inc.

KSA Environmental Laboratory Inc. February 26, 07 KSA Environmental Laboratory Inc. Hydrologic Associates - Miami Attn: Brad Waller 8925 S.W. 148th Street Suite 212 Miami, FL 33176 RE: Parkland KSA Workorder: Q0012 Dear Brad Waller, Enclosed

More information

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7B Triple Quadrupole GC/MS Application Note Authors Dale R. Walker and Fred Feyerherm Agilent Technologies, Inc.

More information

Understanding Gas Chromatography

Understanding Gas Chromatography Understanding Gas Chromatography What is Really Going on Inside the Box? Simon Jones GC Applications Engineer Page 1 Group/Presentation Title Month ##, 200X ?? K? Page 2 Typical GC System Gas supply Injector

More information

Hans-Joachim Hubschmann. Handbook ofgc-ms. Fundamentals and Applications. Third Edition. Wl LEY-VCH. VerlagGmbH & Co. KG aa

Hans-Joachim Hubschmann. Handbook ofgc-ms. Fundamentals and Applications. Third Edition. Wl LEY-VCH. VerlagGmbH & Co. KG aa Hans-Joachim Hubschmann Handbook ofgc-ms Fundamentals and Applications Third Edition Wl LEY-VCH VerlagGmbH & Co. KG aa VII Foreword XIII Preface to the Third Edition XV 1 Introduction 1 1.1 The Historical

More information

METHOD 5000 SAMPLE PREPARATION FOR VOLATILE ORGANIC COMPOUNDS

METHOD 5000 SAMPLE PREPARATION FOR VOLATILE ORGANIC COMPOUNDS METHOD 5000 SAMPLE PREPARATION FOR VOLATILE ORGANIC COMPOUNDS 1.0 SCOPE AND APPLICATION 1.1 Method 5000 provides general guidance on the selection of sample preparation methods (purge-and-trap, extraction,

More information

METHOD 8000B DETERMINATIVE CHROMATOGRAPHIC SEPARATIONS

METHOD 8000B DETERMINATIVE CHROMATOGRAPHIC SEPARATIONS METHOD 8000B DETERMINATIVE CHROMATOGRAPHIC SEPARATIONS 1.0 SCOPE AND APPLICATION 1.1 Method 8000 is not a determinative method but instead provides guidance on analytical chromatography and describes calibration

More information

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis A. Caruso, M. Santoro, P. Magni, S. Pelagatti, and R. Facchetti Thermo Fisher Scientific, Milan,

More information

GC Analysis of Polybrominated Flame Retardants Application

GC Analysis of Polybrominated Flame Retardants Application GC Analysis of Polybrominated Flame Retardants Application Environmental Authors Eberhardt Kuhn, Jason Ellis Agilent Technologies, Inc. 91 Blue Ravine Rd, Folsom, CA 9563 USA Steve Wilbur Agilent Technologies,

More information

Challenging Pesticide Analysis Using an Agilent J&W DB-35ms Ultra Inert GC Column

Challenging Pesticide Analysis Using an Agilent J&W DB-35ms Ultra Inert GC Column Challenging Pesticide Analysis Using an Agilent J&W DB-ms Ultra Inert GC Column Application Note Food Analysis and Environmental Authors Ken Lynam and Doris Smith Agilent Technologies, Inc. 80 Centerville

More information

Technical Report. Abstract: Pu Wang 1, Huizhong Sun 1, Qinghua Zhang 1, Feifei Tian 2, Lei Cao 2

Technical Report. Abstract: Pu Wang 1, Huizhong Sun 1, Qinghua Zhang 1, Feifei Tian 2, Lei Cao 2 C46-E299 Technical Report Determination of Polychlorinated Dibenzo-p-dioxins and Dibenzofurans (PCDD/Fs) in Foodstuffs and Animal Feed Using a Triple Quadrupole GCMS-TQ8040 System with Smart MRM Transforms

More information

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011 ?? Kβ? Page 1 Typical GC System Gas supply Injector Detector Data handling GAS Column Oven Page 2 CARRIER GAS Carries the solutes down the column Selection and velocity influences efficiency and retention

More information

ApplicationNOTE Abstract

ApplicationNOTE Abstract Abstract It has long been known that a range of non-native, stable, saturated hydrocarbon biomarkers present in crude oil extracts could be used to identify the original facie from which the oil was formed.

More information

Optimizing GC Parameters for Faster Separations with Conventional Instrumentation

Optimizing GC Parameters for Faster Separations with Conventional Instrumentation Optimizing GC Parameters for Faster Separations with Conventional Instrumentation Anila I. Khan, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 243 Key Words TraceGOLD fast GC analysis

More information

Capillary GC Column Selection and Method Development A Primer on Column Parameters and Instrument Conditions

Capillary GC Column Selection and Method Development A Primer on Column Parameters and Instrument Conditions Capillary GC Column Selection and Method Development A Primer on Column Parameters and Instrument Conditions Michael D. Buchanan September 11, 2014 sigma-aldrich.com/analytical 2012 Sigma-Aldrich Co. All

More information

Study of Residual Solvents in Various Matrices by Static Headspace

Study of Residual Solvents in Various Matrices by Static Headspace Application Note Abstract United States Pharmacopeia (USP) chapter is a widely used method for identifying and quantifying Organic Volatile Impurities (OVI) used in the production of pharmaceuticals.

More information

Using Magnetic Sector GC-HRMS in a Commercial Dioxin Lab

Using Magnetic Sector GC-HRMS in a Commercial Dioxin Lab An Executive Summary Using Magnetic Sector GC-HRMS in a Commercial Dioxin Lab David Hope Chief Executive Officer Pacific Rim Laboratories Introduction Persistent organic pollutants (POPs) are toxic chemicals

More information

The Third Dimension of Information Vol. IV Applications with the Agilent Technologies Atomic Emission Detector. O H Cl. Fe Se

The Third Dimension of Information Vol. IV Applications with the Agilent Technologies Atomic Emission Detector. O H Cl. Fe Se The Third Dimension of Information Vol. IV Applications with the Agilent Technologies Atomic Emission Detector O H Cl Sn Fe Se S Author: Bernhard Rothweiler, Agilent Technologies Deutschland GmbH Index:

More information

PhenogelTM Non-Aqueous GPC/SEC Columns

PhenogelTM Non-Aqueous GPC/SEC Columns PhenogelTM Non-Aqueous GPC/SEC Columns Improve Resolution Wide solvent compatibility Temperature stability up to 140 C Narrow bore columns available for reduced solvent consumption Phenogel GPC Materials

More information

Class III Wastewater Laboratory Analyst Examination Study Guide 2008

Class III Wastewater Laboratory Analyst Examination Study Guide 2008 Class III Wastewater Laboratory Analyst Examination Study Guide 2008 Specific laboratory analyses included on Class III Exam: All Information and tests from Class I and Class II Plus the following - Biological

More information

Introduction to Capillary GC

Introduction to Capillary GC ?? Kβ? Page 1 Typical GC System Gas supply Injector Detector Data handling GAS Column Oven Page 2 CARRIER GAS Carries the solutes down the column Selection and velocity influences efficiency and retention

More information

Application. Gas Chromatography March 1998

Application. Gas Chromatography March 1998 Micro Liquid-Liquid Extraction with the Agilent 7683 Automatic Liquid Sampler Application Gas Chromatography March 1998 Authors Matthew S. Klee Agilent Technologies, Inc. 285 Centerville Road Wilmington,

More information

A Review of Solid Phase Sorbents Over Time As Applied to Environmental Applications. Page 1 Biotage

A Review of Solid Phase Sorbents Over Time As Applied to Environmental Applications. Page 1 Biotage A Review of Solid Phase Sorbents Over Time As Applied to Environmental Applications Page 1 Bill Jones 8 August 2018 Abstract» Sample preparation using solid phase extraction (SPE) has been in use for several

More information

PosterReprint INTRODUCTION

PosterReprint INTRODUCTION INTRODUCTION 'Dioxins' refers to a group of chemical compounds that share certain similar chemical structures and biological characteristics. Several hundred of these toxic compounds exist and are members

More information

Grace GC Capillary Column Families

Grace GC Capillary Column Families Grace GC Capillary Column Families Alltech Heliflex High-Performance, Widest Selection of Phases Alltech Econo-Cap Best Value, Popular Phases Grace offers two lines of capillary columns to suit every application

More information

Pesticides Analysis Using the Agilent 5977A Series GC/MSD

Pesticides Analysis Using the Agilent 5977A Series GC/MSD Pesticides Analysis Using the Agilent 5977A Series GC/MSD Application Note Food Testing and Agriculture Authors Jia-jia Wu and Wen-wen Wang Agilent Technologies Co. Ltd (China) Beijing, People s Republic

More information

Enhance Resolution FOR POLYMER ANALYSIS, Guaranteed *

Enhance Resolution FOR POLYMER ANALYSIS, Guaranteed * Enhance Resolution FOR POLYMER ANALYSIS, Guaranteed * Remarkable Reproducibility Exceptional Efficiency Long Lifetimes Economically Priced www.phenomenex.com/phenogel Phenogel Non-Aqueous GPC/SEC Columns

More information

The Suite for Environmental GC Analysis

The Suite for Environmental GC Analysis The Suite for Environmental GC Analysis SGE Environmental GC Columns Performance Selectivity Delivery Promise www.sge.com SGE Environmental GC Columns The Suite for Environmental GC Analysis SGE GC Columns

More information

High Throughput Multi-Residue Screening of Drinking Water using the SPE-DEX~ and Pegasus GC-TOF-MS

High Throughput Multi-Residue Screening of Drinking Water using the SPE-DEX~ and Pegasus GC-TOF-MS Application Note No. 098 High Throughput Multi-Residue Screening of Drinking Water using the SPE-DEX~ and Pegasus GC-TOF-MS Steve Scott, Thames Water, Reading, UK Diane Turner. Introduction In cases of

More information

AppNote 6/2004. Thermal Desorption GC Analysis of High Boiling, High Molecular Weight Hydrocarbons SUMMARY

AppNote 6/2004. Thermal Desorption GC Analysis of High Boiling, High Molecular Weight Hydrocarbons SUMMARY AppNote 6/2004 Thermal Desorption GC Analysis of High Boiling, High Molecular Weight Hydrocarbons Edward A. Pfannkoch, Jacqueline A. Whitecavage, and Jeffrey Christenson Gerstel, Inc., 701 Digital Drive,

More information

Polychlorinated biphenyls (PCBs)

Polychlorinated biphenyls (PCBs) Polychlorinated biphenyls (PCBs) 3 2 2 3 4 4 ()n 5 6 6 5 ()m Polychlorinated biphenyls (PCBs) have been the subject of a broad range of studies and investigations because of their environmental persistency

More information

SUPELCO. The Analysis of all 209 PCB Congeners on the SPB -Octyl and MDN -5S Capillary Columns. Katherine K. Stenerson and Leonard M.

SUPELCO. The Analysis of all 209 PCB Congeners on the SPB -Octyl and MDN -5S Capillary Columns. Katherine K. Stenerson and Leonard M. SUPELCO The Analysis of all 209 PCB Congeners on the SPB -Octyl and MDN -5S Capillary Columns Katherine K. Stenerson and Leonard M. Sidisky Supelco, Supelco Park, Bellefonte, PA USA 2000 Sigma-Aldrich

More information

Spectra Library Electron Capture Negative Ion (ECNI) Mass Spectra of Selected Polybrominated Diphenyl Ethers (PBDEs)

Spectra Library Electron Capture Negative Ion (ECNI) Mass Spectra of Selected Polybrominated Diphenyl Ethers (PBDEs) Spectra Library Electron Capture Negative Ion (ECNI) Mass Spectra of Selected Polybrominated Diphenyl Ethers (PBDEs) The following 63 mass spectra were measured by gas chromatography (GC) (6890N, Agilent

More information

40 % OFF. Upgrade to Zebron GC Columns. Equivalent Selectivity. Better Service. ZB-1ms ZB-5 ZB-624. ZB-5ms ZB-WAX ZB-1.

40 % OFF. Upgrade to Zebron GC Columns. Equivalent Selectivity. Better Service. ZB-1ms ZB-5 ZB-624. ZB-5ms ZB-WAX ZB-1. Upgrade to Zebron GC Columns Equivalent Selectivity. Better Service. ZB-ms ZB-5 ZB-64 ZB- 40 % OFF Zebron GC columns ZB-WAX ZB-5ms * Expires: October 30, 009 Please Mention Offer Code: ZBE009 * Offer applies

More information

Residual Solvents in Pharmaceuticals by USP Chapter <467> Methodology

Residual Solvents in Pharmaceuticals by USP Chapter <467> Methodology APPLICATION NOTE Gas Chromatography Author: David Scott PerkinElmer, Inc. Shelton, CT Residual Solvents in Pharmaceuticals by USP Chapter Methodology Introduction The synthesis of active pharmaceutical

More information

Presentation Title. Isotope Dilution: Where it doesn t work Where we should expand its use. August 10, David I. Thal Principal Chemist

Presentation Title. Isotope Dilution: Where it doesn t work Where we should expand its use. August 10, David I. Thal Principal Chemist Presentation Title Isotope Dilution: Subtitle Where / Author it works Where it doesn t work Where we should expand its use August 10, 2017 David I. Thal Principal Chemist Isotope Dilution - Definitions

More information

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1 Application Note Meeting the Korean Method ES 04602.1b for Vinyl Chloride, Acrylonitrile, and Bromoform ( 염화비닐, 아크릴로니트릴, 브로모포름 ) with Static and Dynamic Headspace GC/MS Roger Bardsley, Applications Chemist;

More information

Low Bleed Stationary Phases for Gas Chromatography

Low Bleed Stationary Phases for Gas Chromatography Low Bleed Stationary Phases for Gas Chromatography Slide 4 Advantages of Low Bleed Phase Lower bleed compared to standard phases Better signal to noise (sensitivity) Higher upper temperature - shorter

More information

Application Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS

Application Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS Application Note #1820230 Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS GC-MS Introduction USEPA Method 8270 [1] for semivolatiles is is used by by laboratories to measure

More information

Sample Prep Solutions for Environmental Contaminants

Sample Prep Solutions for Environmental Contaminants Sample Prep Solutions for Environmental Contaminants Lisa Lenehan Sales Support Specialist for Sample Prep Products, Thermo Fisher Scientific August 2017 The world leader in serving science What is the

More information

[ Care and Use Manual ]

[ Care and Use Manual ] Oasis HLB DISKS I. Introduction Oasis HLB is a Hydrophilic-Lipophilic-Balanced, water-wettable, reversed-phase sorbent for all your SPE needs. It is made from a specific ratio of two monomers, the hydrophilic

More information

Zebron MultiResidue GC Columns

Zebron MultiResidue GC Columns Zebron MultiResidue GC Columns A new Generation of Columns for Pesticide Analysis MultiResidue Optimized for pesticide, herbicide and insecticide analysis The use of many pesticides has been limited or

More information

Detection of Volatile Organic Compounds in polluted air by an Agilent mini Thermal Desorber and an Agilent 5975T LTM GC/MS

Detection of Volatile Organic Compounds in polluted air by an Agilent mini Thermal Desorber and an Agilent 5975T LTM GC/MS Detection of Volatile Organic Compounds in polluted air by an Agilent mini Thermal Desorber and an Agilent 5975T LTM GC/MS Application Note Environmental Author Xiaohua Li Agilent Technologies (Shanghai)

More information

Product Brief. - Hydrocarbons alkanes, alkenes, alkynes, dienes including natural gas, refinery gas, liquified petroleum gas

Product Brief. - Hydrocarbons alkanes, alkenes, alkynes, dienes including natural gas, refinery gas, liquified petroleum gas Agilent Porous Polymer PLOT Columns: New Products, Expanded Uses, Prices Cut in Half! Product Brief Need improved resolution of small volatile compounds? Didn't try a PLOT column due to high price, short

More information

Zebron MultiResidue GC Columns

Zebron MultiResidue GC Columns Zebron MultiResidue GC Columns A New Generation of Columns for Pesticide Analysis MultiResidue Optimized for pesticide, herbicide and insecticide analysis The use of many pesticides has been limited or

More information

METHOD 8081B ORGANOCHLORINE PESTICIDES BY GAS CHROMATOGRAPHY

METHOD 8081B ORGANOCHLORINE PESTICIDES BY GAS CHROMATOGRAPHY METHOD 8081B ORGANOCHLORINE PESTICIDES BY GAS CHROMATOGRAPHY 1.0 SCOPE AND APPLICATION 1.1 Method 8081 may be used to determine the concentrations of various organochlorine pesticides in extracts from

More information

Validation of GC-MS/MS for Detection and Confirmation of Low-Level Dioxins

Validation of GC-MS/MS for Detection and Confirmation of Low-Level Dioxins Validation of GC-MS/MS for Detection and Confirmation of Low-Level Dioxins Cristian Cojocariu, 1 Paul Silcock, 1 and Alexander Kotz 2 1 Thermo Fisher Scientific, Runcorn, U.K. 2 European Union Reference

More information

A New PEG GC Column with Improved Inertness Reliability and Column Lifetime Agilent J&W DB-WAX Ultra Inert Polyethylene Glycol Column

A New PEG GC Column with Improved Inertness Reliability and Column Lifetime Agilent J&W DB-WAX Ultra Inert Polyethylene Glycol Column A New PEG GC Column with Improved Inertness Reliability and Column Lifetime Agilent J&W DB-WAX Ultra Inert Polyethylene Glycol Column Competitive Comparison Authors Ngoc-A Dang and Allen K. Vickers Agilent

More information

Helium conservation in volatile organic compound analysis using U.S. EPA Method 8260C

Helium conservation in volatile organic compound analysis using U.S. EPA Method 8260C APPLICATION NOTE 10441 Helium conservation in volatile organic compound analysis using U.S. EPA Method 8260C Authors Andrea Caruso, 1 Tommaso Albertini, 1 Jacob A. Rebholz 2 ; 1 Thermo Fisher Scientific,

More information