Analysis. Priority LC GC. Zebron PAH Accurately quantitate EU and EPA PAHs in less than 28 minutes
|
|
- May Grant
- 5 years ago
- Views:
Transcription
1 Priority Analysis LC GC Core-Shell Technology GC Columns Kinetex PAH Expanded resolution with chemical selectivity specifically for PAHs Increased throughput and sensitivity with core-shell technology for HPLC/UHPLC Zebron PAH Accurately quantitate EU and EPA PAHs in less than minutes Excellent separation for critical PAH isomers
2 FASTER, BETTER RE Kinetex Core-Shell Technology The Chosen Core-Shell Brand Kinetex Core-Shell Technology delivers dramatic improvements in efficiency over conventional fully porous media which can be leveraged to increase resolution, greatly improve productivity, reduce solvent consumption, and decrease costs. Whether you are running HPLC or UHPLC methods, the Kinetex core-shell family can deliver shockingly improved performance over the current column you are using. Solid Core Porous Shell Finely Tuned, Unique Core-Shell Manufacturing Process Phenomenex designs, manufactures, and sells its very own silica and organo-silica core-shell particles. Using silica sol-gel processing techniques that incorporate nano-structuring technology, a durable, homogeneous porous shell is grown on a solid silica core to create a core-shell particle. The combination of a consistent, solid high density core along with proprietary column packing technologies ensures optimum bed structure and high column performance. LC Typical Core-Shell Performance Gains! mau Kinetex Core-Shell Fully Porous You can unleash the power of Kinetex Core-Shell Technology columns to achieve faster and better results just not possible on conventional fully porous materials. No matter what type of system you have or type of analysis you are performing, there is a Kinetex solution for you. 1 App ID min 1 Phenomenex, Inc. All rights reserved. Phenomenex l WEB:
3 ESULTS DRIVEN BY: Zebron Gas Chromatography Technology Continued Innovation with GC Expertise Our inventive GC scientists have + years of experience, and many helped create keystone phases at J&W Scientific before joining the Phenomenex team. Zebron s track record of innovation is the only to be recognized with R&D 1 Awards and Readers Choice awards! This tradition of GC innovation continues even into 1 with the release of the ZB-, ZB-, ZB-FAME and ZB-PAH. NE W ZB-FAME Faster results and improved separation of cis/trans FAME isomers GC Birth of Zebron GC Columns 199 ZB-WAXplus 1 % water stable MS Phases Low bleed, sensitive performance Inferno Phases Stable up to C ZB-MultiResidue Phases Targeted selectivity for pesticide screening ZB-1XT SimDist Robust simulated distillation 9 ZB-Drug-1 For drugs of abuse ZB-Bioethanol min results 1 1 ZB-PAH Accurate PAH analysis from food and environmental samples ZB-CLPesticides Phases Versatility for pesticides by GC/ECD 1 ZB-SemiVolatiles Supreme inertness for environmental SVOCs, PBDEs, and PAHs 1 1 ZB-MSplus Versatile, inert performance for industrial and food applications More Than Just A Column When you choose Zebron, you get more than just high quality GC products. Choosing Zebron means you get access to a wide variety of tools, resources, and personalized support to help make your GC work easier, faster, and simply better. TRY MIS E H SE C N PHA ATIO V I T C DEA CA SILI D E FUS Phenomenex l WEB:
4 Designed for PAH Analysis by HPLC/UHPLC Innovative Polymerically Bonded C1 Core-Shell PAH Column! Si Si O Si Si O Polycyclic aromatic hydrocarbons (PAHs) are a hazardous set of compounds that come from a variety of materials and processes. With the need to accurately identify toxic forms of these compounds quickly in the environmental, fuel, food industries, we specifically developed the first core-shell based LC product for PAH analysis. Now high resolution PAH separations can be attained under fast run times on both HPLC or UHPLC instrumentation. O O PAH QC tested for PAHs (EPA 1) Enhanced resolution and performance for PAH analysis Controlled pore size processing and a proprietary polymerically bonded stationary phase were developed to ensure excellent resolution between priority polycyclic aromatic hydrocarbons (PAHs). Combined with core-shell particle technology, incredibly high efficiency and sensitivity at comfortable LC pressures is very achievable. Have either an HPLC or UHPLC? No worries! The Kinetex PAH.µm core-shell particle size and format has been chosen to provide optimal performance on both HPLC and UHPLC instrumentation. Learn More Online Find more methods and applications online at Phenomenex l WEB:
5 EPA and EU Core-Shell Technology LC Application Examples EPA 1 PAH Analysis mau min App ID 1 Column: Kinetex. µm PAH Dimensions: 1 x. mm Part No.: D--E Mobile Phase: A: Water B: Acetonitrile Gradient: Time (min) % B Flow Rate: 1. ml/min Backpressure: 1 Bar Temperature: C Detection: 9 nm Sample: 1. Naphthalene. Acenaphthylene. Acenaphthene. Fluorene. Phenanthrene. Anthracene. Fluoranthene. Pyrene 9. Benzo[a]anthracene 1. Chrysene. Benzo[b]fluoranthene 1. Benzo[k]fluoranthene 1. Benzo[a]pyrene 1. Dibenzo[a,h]anthracene 1. Benzo[ghi]perylene 1. Indeno[1,,-cd]pyrene EPA 1 PAH Analysis 1 mau min App ID 1 Column: Kinetex. µm PAH Dimensions: 1 x. mm Part No.: D--E Mobile Phase: A: Water B: Acetonitrile Gradient: Time (min) % B Flow Rate: 1. ml/min Backpressure: 1 Bar Temperature: C Detection: 9 nm Sample: 1. Naphthalene 1. Pyrene. Acenaphthylene. 1-Methylnaphthalene. -Methylnaphthalene. Acenaphthene. Fluorene. Phenanthrene. Anthracene 9. Fluoranthene. Benzo[a]anthracene 1. Chrysene 1. Benzo[b]fluoranthene 1. Benzo[k]fluoranthene 1. Benzo[a]pyrene 1. Dibenzo[a,h]anthracene 1. Benzo[ghi]perylene 1. Indeno[1,,-cd]pyrene EU 1+1 PAH Analysis mau min App ID 1 Column: Kinetex. µm PAH Dimensions: 1 x. mm Part No.: D--E Mobile Phase: A: Water B: Acetonitrile Gradient: Time (min) % B Flow Rate: 1. ml/min Backpressure: 1 Bar Temperature: C Detection: 9 nm Sample: 1. Benzo[c]fluorene. Cyclopenta[cd]pyrene. Benzo[a]anthracene. Chrysene. -Methylchrysene. Benzo[j]fluoranthene. Benzo[b]fluoranthene. Benzo[k]fluoranthene 9. Benzo[a]pyrene 1. Dibenzo[a,l]pyrene. Dibenz[a,h]anthracene 1. Benzo[ghi]perylene 1. Indeno[1,,-cd]pyrene 1. Dibenzo[a,e]pyrene 1. Dibenzo[a,i]pyrene 1. Dibenzo[a,h]pyrene Phenomenex l WEB:
6 Designed for PAH Analysis by GC Zebron ZB-PAH columns are manufactured and tested to provide the most optimal performance for EU-regulated polycyclic aromatic hydrocarbons (PAHs). The columns are individually tested with an application-specific QC test probe mixture and deliver excellent resolution of critical PAH isomers, such as benzo[b,j,k]fluoranthene. Cross-Linked Bonding Reinforces stationary phase with incorporation of ladders into polymer backbone Very low bleed propietary stationary phase is applied to the deactivated surface Low Bleed Stationary Phase Deactivated Surface Durable Polyimide Coating With exceptional thermal stability and low column bleed at elevated temperatures, ZB-PAH columns bring the added benefit of good column lifetime alongside a consistent column inertness that promotes accurate baseline resolution for critical isomer pairs. Fit for Purpose Testing ZB-PAH columns are verified with tight industry QC specifications for column bleed, sensitivity, and performance to provide you utmost confidence in qualitative and quantitative results for the analysis of PAHs. QC tested for PAHs Exceptional thermal stability and low column bleed Remarkably Inert! Easy Liner Selection Our GC liner finder tool makes liner selection a breeze. You can even search by application, injection type, GC system, or your current liner part number. Phenomenex l WEB:
7 EPA and EU GC Columns GC Application Examples EU 1+1 PAH Analysis Separation of Key PAHs App ID 1 Column: Zebron ZB-PAH Dimension: meter x.1 mm x.1 µm Part No.: FD-G- Injection: C,. µl Carrier Gas: 1mL/min (constant flow) Oven Program: C for. min to C/min to C/min to C/min to C/min to 1 C/ min for. min Detector: C; - amu Sample: 1. Benzo[c]fluorene. Benz[a]anthracene. Cyclopenta[c,d]pyrene. Chrysene. -Methylchrysene. Benzo[b]fluoranthene. Benzo[k]fluoranthene. Benzo[j]fluoranthene 9. Benz[a]pyrene 1. Indeno[1,,-cd]pyrene. Dibenzo[a,h]anthracene 1. Benzo[g,h,i]perylene 1. Dibenzo[a,l]pyrene 1. Dibenzo[a,e]pyrene 1. Dibenzo[a,i]pyrene 1. Dibenzo[a,lh]pyrene Expanded EU 1+1 and EPA 1 PAH Analysis min App ID 9 Column: Zebron ZB-PAH Dimension: meter x.1 mm x.1 µm Part No.: FD-G- Injection: C,. µl Carrier Gas: 1. ml/min (constant flow) Oven Program: C for. min to 1 C/min to C/ min for min to C/min for min to C/min for min Detector: C; - amu Sample: 1. Naphthalene. Acenaphthylene. Acenaphthene. Fluorene. Phenanthrene. Anthracene. Flouranthene. Pyrene 9. Benzo[c]fluorene 1. Benzo[a]anthracene. Cyclopenta[c,d]pyrene 1. Chrysene 1. N-Methylchrysene 1. Benzo[b]fluoranthene 1. Benzo[k]fluoranthene 1. Benzo[j]fluoranthene 1. Benzo[a]pyrene 1. Indeno[1,,-cd]pyrene 19. Dibenz[a,h]anthracene. Benzo[g,h,i]perylene 1. Dibenzo[a,l]pyrene. Dibenzo[a,e]pyrene. Dibenzo[a,i]pyrene. Dibenzo[a,h]pyrene GC-MS Analysis of PAHs in Rubber and Plastic min App ID Column: Zebron ZB-PAH Dimension: meter x.1 mm x.1 µm Part No.: FD-G- Injection: 9 C, 1 µl Carrier Gas: cm/sec (constant flow) Oven Program: 1 C for 1. min to C/min for. min to C/min to C/min Detector: C; - amu Sample: 1. Naphthalene-d. Naphthalene. -Methylnaphthalene. 1-Methylnaphthalene. Acenaphthylene. Acenaphthylene-d1. Acenaphthene. Fluorene 9. Phenanthrene-d1 1. Phenanthrene. Anthracene 1. Fluoranthene 1. Pyrene 1. p-terphenyl-d1 1. Benzo[a]anthracene 1. Chrysene-d1 1. Chrysene 1. Benzo[b]fluoranthene 19. Benzo[k]fluoranthene. Benzo[j]fluoranthene 1. Benzo[e]pyrene. Benzo[a]pyrene. Perylene-d1. Indeno[1,,-cd]pyrene. Dibenz[a,h]anthracene. Benzo[g,h,i]perylene Phenomenex l WEB:
8 Easily improve your sensitivity and recovery before analysis! With the widest range of sample preparation solutions from Phenomenex you can clean up any matrix before testing for PAHs! roq Type: QuEChERS (Quick, Easy, Cheap, Effective, Rugged, and Safe) Description: Quick and efficient process to extract multi-residue target analytes from food samples while removing unwanted interferences such as organic acids, lipids, pigments, sugars, and more. Each kit contain centrifuge tubes, pre-weighed salts in convenient single-use packets, and pre-weighed and packed SPE centrifuge tubes. Strata Silica SPE Type: Solid Phase Extraction Description: Reversed phase, normal phase, or ion-exchange based media that allows for direct retention and elution of compounds of interest, with wash steps to remove unwanted interferences. Available in tubes (ranging from 1 ml to ml) and 9-well plate formats. Strata PAH is available for clean up of water samples. Solid Phase Extraction Strata-X Polymeric SPE Type: Solid Phase Extraction Description: Unique, combined reverse phase and ion-exchange polymeric media developed to cover a diverse spectrum of analytes and simplify the method development process for fast and efficient sample preparation. Available in tubes (ranging from 1 ml to ml) and standard and microelution 9-well plate formats. Polymeric SPE
9 Ordering Information Kinetex SecurityGuard ULTRA. μm Minibore Columns (mm) Cartridges (mm) Phase x.1 1 x.1 1 x.1 /pk PAH B--AN D--AN F--AN AJ-9 for.1 mm ID SecurityGuard ULTRA. μm MidBore (mm) Cartridges (mm) Phase 1 x. /pk PAH D--Y AJ-9 for. mm ID SecurityGuard ULTRA. μm Analytical Columns (mm) Cartridges (mm) Phase 1 x. 1 x. x. /pk PAH D--E F--E G--E AJ-9 for. mm ID *SecurityGuard ULTRA Cartridges require holder, Part No.: AJ-9 Zebron Phase ID (mm) df (µm) Length (m) Part No. ZB-PAH.1.1 FD-G- ZB-PAH.. HG-G- ZB-PAH.. KG-G- Sample Preparation Find part numbers, phases and sizes for our sample preparation solutions through the following links: roq QuEChERS: Strata Silica SPE Strata-X Polymeric SPE If Phenomenex LC and GC columns in this brochure do not provide at least equivalent separations to a competing column of the same phase, particle size, and dimensions, return the Phenomenex column with comparative data within days for a FULL REFUND. 9
10 Find more methods and applications online at Priority Analysis Australia t: +1 ()-9- f: +1 ()-9- Austria t: + ()1-19- f: + () anfrage@phenomenex.com Belgium t: + () 1 (French) t: + () (Dutch) f: +1 ()-9 beinfo@phenomenex.com Canada t: +1 () -1 f: +1 (1) - info@phenomenex.com China t: f: + () -1 phen@agela.com Denmark t: + f: + 1 nordicinfo@phenomenex.com Finland t: + ()9 9 f: + 1 nordicinfo@phenomenex.com France t: + () f: + ()1 9 1 franceinfo@phenomenex.com Germany t: +9 ()1-- f: +9 ()1-- anfrage@phenomenex.com India t: +91 ()-1 f: +91 ()-1 indiainfo@phenomenex.com Ireland t: + ()1 f: eireinfo@phenomenex.com Luxembourg t: +1 ()-1 f: +1 ()-9 nlinfo@phenomenex.com Mexico t: 1--- f: tecnicomx@phenomenex.com The Netherlands t: +1 ()-1 f: +1 ()-9 nlinfo@phenomenex.com New Zealand t: + ()9-91 f: + ()9-9 nzinfo@phenomenex.com Norway t: + 1 f: + 1 nordicinfo@phenomenex.com Puerto Rico t: +1 () 1-HPLC f: +1 (1) - info@phenomenex.com Spain t: f: espinfo@phenomenex.com Sweden t: + () 9 f: + 1 nordicinfo@phenomenex.com United Kingdom t: + ()1-1 f: + ()1-19 ukinfo@phenomenex.com USA t: +1 (1) 1- f: +1 (1) - info@phenomenex.com All other countries Corporate Office USA t: +1 (1) 1- f: +1 (1) - info@phenomenex.com Italy t: +9 1 f: +9 1 italiainfo@phenomenex.com Phenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department at international@phenomenex.com BR1_W Terms and Conditions Subject to Phenomenex Standard Terms & Conditions, which may be viewed at Trademarks Kinetex and Strata are registered trademarks and Zebron, Inferno, MultiResidue, WAXplus, MSplus, roq and SecurityGuard are trademarks of Phenomenex. Strata-X is patented by Phenomenex. U.S. Patent No.,9,1, 1 Phenomenex, Inc. All rights reserved.
AGGREGATE ANALYSIS. Biologics Workflow. by Size Exclusion Chromatography
Biologics Workflow AGGREGATE ANALYSIS by Size Exclusion Chromatography New biozen SEC columns provide: High efficiency on both HPLC and UHPLC Extreme inertness and robustness Finely tuned high and low
More informationGemini-NX Performance paired with Axia Technology
Si Si Si Si Si Si Si C Si Si Si Si Si Gemini-NX Performance paired with Axia Technology Gemini -NX Axia Packed Technology Improves Yield, Throughput, and Column Lifetime Ideal Purification Platform While
More informationYour Reversed Phase Method
PLC Columns for Your Reversed Phase Method Balanced Non-Polar & Polar Selectivity Strong Non-Polar & Polar Selectivity Strong Polar & Aromatic Selectivity Unique Isomeric & alogenated Selectivity Robust
More informationAPPLICATIONS TN Peptide Purification Method Development: Application for the Purification of Bivalirudin. Introduction
Peptide Purification Method Development: Application for the Purification of Bivalirudin Marc Jacob, Joshua Heng, and Tivadar Farkas Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 91 USA In this technical
More informationAPPLICATIONS TN Increased Capabilities for the Analysis of Hormones in Drinking and Waste Water Using Solid Phase Extraction (SPE) and LC/MS/MS
Increased Capabilities for the Analysis of Hormones in Drinking and Waste Water Using Solid Phase Extraction (SPE) and LC/MS/MS Xianrong (Jenny) Wei Senior Scientist Jenny is a Senior Scientist in Phenomenex
More informationQuick and Simple Cleanup for. Medicinal Chemistry. It s BIG.
Quick and Simple Cleanup for Medicinal It s IG. Guaranteed Cleanup of Post Synthesis Reactions Strata -XL Giga s are designed to make Medicinal easy! With Strata Giga tubes I ve been able to purify a compound
More informationRely on Rxi -PAH Columns
Rely on Rxi -PAH Columns to Ensure Successful Polycyclic Aromatic Hydrocarbon (PAH) Analysis Optimized Efficiency, Selectivity, and Robustness Let You: Report accurate results with speed and confidence.
More informationDetermination of 24 PAHs in Drinking Water
Determination of 24 PAHs in Drinking Water Application Note Food Testing and Agriculture Authors M.C. Díaz Ramos, A. Suárez, A. Rúbies, and R. Companyó Laboratori de l Agencia de Salut Publica de Barcelona
More informationAccelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil
Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil Che Jinshui, 1 Deng Guifeng, 1 Liang Lina, 1 and Aaron Kettle, 2 1 Thermo Fisher Scientific (China)
More informationPAH Analyses with High Efficiency GC Columns: Column Selection and Best Practices
PAH Analyses with High Efficiency GC Columns: Column Selection and Best Practices Food Quality and Environmental Author Ken Lynam Agilent Technologies, Inc. 280 Centerville Road Wilmington, DE 19808 Abstract
More informationDetermination of Polycyclic Aromatic Hydrocarbons (PAHs) in Seafood Using GC/MS
Determination of Polycyclic Aromatic Hydrocarbons (PAHs) in Seafood Using GC/MS UCT Part Numbers: ECQUUS2-MP (4 g of muffled anh. MgSO 4 and 2 g of NaCl) ECPAHFR50CT (50 ml centrifuge tubes, PAHs removed)
More informationNew ZB-5HT Inferno The World s Highest Temperature Non-Metal GC Column
New ZB-5HT Inferno The World s Highest Temperature Non-Metal GC Column The World's First Non-metal 5% Phenyl Phase GC Column Rated to 430 C * Specially processed for thermal stability up to 430 C A true
More informationAPPLICATIONS TN Separation and Quantitation of Physiologic Cobalamins (Vitamin B 12
APPLICATIONS Separation and Quantitation of Physiologic Cobalamins (Vitamin B 12 in Dietary Supplements by LC/MS/MS using Synergi Fusion-RP Column Xianrong (Jenny Wei Senior Scientist PhenoLogix applications
More informationDeveloping Large Volume Injection (LVI) in Split / Splitless Inlets. Philip J. Koerner Phenomenex Inc. NEMC 2014
Developing Large Volume Injection (LVI) in Split / Splitless Inlets Philip J. Koerner Phenomenex Inc. NEMC 2014 Goal To produce a method that provides the largest response of analytes that will produce
More informationFast, Accurate Environmental Testing
GC Columns Fast, Accurate Environmental Testing Using Zebron GC Columns Featuring Pesticides Diesel Range Organics Semivolatiles Dioxane And more.. www.phenomenex.com/environmental Semi-Volatile Organic
More informationThe Standard for ph Method Development
The Standard for ph Method Development High Efficiency Excellent Lifetime ph Stable - www.phenomenex.com/gemini U.S. Patent No.,, Setting the Standard for ph Method Development Gemini columns are rugged
More informationAPPLICATIONS TN Lux Cellulose-2 or -4 Cellulose tris (3-chloro-4-methylphenylcarbamate) or (4-chloro-3-methylphenylcarbamate)
T-1079 APPLICATI Method Development for Reversed Phase Chiral LC/M/M Analysis of tereoisomeric Pharmaceutical Compounds with Polysaccharide-based tationary Phases Philip J. Koerner, Kari Carlson, Liming
More informationAPPLICATIONS TN HPLC Conditions. Lux Cellulose-1 Cellulose tris(3,5-dimethylphenylcarbamate)
T-147 APPLICATIS Alternative Selectivity of Chiral Stationary Phases Based on Cellulose tris(3-chloro-4-methylphenylcarbamate) and Cellulose tris(3,5-dimethylphenylcarbamate) Liming Peng, Tivadar Farkas
More informationOptimizing GC Parameters for Faster Separations with Conventional Instrumentation
Optimizing GC Parameters for Faster Separations with Conventional Instrumentation Anila I. Khan, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 243 Key Words TraceGOLD fast GC analysis
More informationMulti-residue Analysis for PAHs, PCBs and OCPs on Agilent J&W FactorFour VF-Xms
Multi-residue Analysis for PAHs, PCBs and OCPs on Agilent J&W FactorFour VF-Xms Application Note Author Laura Provoost Agilent Technologies, Inc. Introduction In multi-residue analysis different groups
More informationAPPLICATIONS TN Detection of Environmental Contaminants Caused by the Oil Spill in the Gulf of Mexico by GC and HPLC
Detection of Environmental Contaminants Caused by the Oil Spill in the Gulf of Mexico by GC and HPLC Sky Countryman, Ngoc Nguyen, Jeff Layne, Kory Kelly, and Zeshan Aqeel Phenomenex, Inc., 411 Madrid Ave.,
More informationTake Your Food Testing to the Next Level
GC Columns Take Your Food Testing to the Next Level Using Zebron GC Columns Featuring Pesticides FAMEs Essential Oils Flavors And more.. www.phenomenex.com/foodgc Pesticide Screening by GC-MS - 7 7 9,9
More informationMETHOD 8100 POLYNUCLEAR AROMATIC HYDROCARBONS
METHOD 8100 POLYNUCLEAR AROMATIC HYDROCARBONS 1.0 SCOPE AND APPLICATION 1.1 Method 8100 is used to determine the concentration of certain polynuclear aromatic hydrocarbons (PAH). Table 1 indicates compounds
More informationKatherine K. Stenerson, Michael Ye, Michael Halpenny, Olga Shimelis, and Leonard M. Sidisky. Supelco, Div. of Sigma-Aldrich Bellefonte, PA USA
New Analytical Tools for the Determination of Persistent Organic Pollutants (POPs) in Fatty Food and Beverage Matrices Using QuEChERS Extraction/Cleanup and Gas Chromatography (GC) Analysis Katherine K.
More informationSensitive and rapid determination of polycyclic aromatic hydrocarbons in tap water
APPLICATION NOTE 70923 Sensitive and rapid determination of polycyclic aromatic hydrocarbons in tap water Authors Chen Jing, Dai Zhenyu, Xu Qun, and Liang Lina, Thermo Fisher Scientific, Shanghai, People
More informationSelection of a Capillary
Selection of a Capillary GC Column - Series 3 Mark Sinnott Application Engineer March 19, 2009 Page 1 Typical Gas Chromatographic System Mol-Sieve Traps Fixed Restrictors Regulators Injection Port Detector
More informationAccurate, Reproducible Results for Environmental Methods with Zebron GC Columns
Accurate, Reproducible Results for Environmental Methods with Zebron GC Columns BUY NOW AND SAVE! Length Sale Price* 10-15 meter $ 199 30 meter $ 399 60 meter $ 599 *Offer valid only for addressee, limit
More informationApplication Note. Abstract. Authors. Environmental
GC/MS Analysis of European Union (EU) Priority Polycyclic Aromatic Hydrocarbons (PAHs) using an Agilent J&W DB-EUPAH GC Column with a Column Performance Comparison Application Note Environmental Authors
More informationSelection of a Capillary GC Column
Selection of a Capillary GC Column Mark Sinnott Application Engineer March 13, 2008 Page 1 Typical Gas Chromatographic System Mol-Sieve Traps Fixed Restrictors Regulators Injection Port Detector Electrometer
More informationApplication Note. Abstract. Introduction. Determination of Polycyclic Aromatic Hydrocarbons in Seafood by an Automated QuEChERS Solution
Application Note Abstract Determination of Polycyclic Aromatic Hydrocarbons in Seafood by an Automated QuEChERS Solution Page 1 Polycyclic Aromatic Hydrocarbons (PAHs) are a large group of organic compounds
More informationApplication Note. Agilent Application Solution Analysis of PAHs in soil according to EPA 8310 method with UV and fluorescence detection.
Agilent Application Solution Analysis of PAHs in soil according to EPA 3 method with UV and fluorescence detection Application Note Environmental Authors Sonja Volk, Angelika Gratzfeld-Huesgen Agilent
More information4. Place a 20 ml VOA vial in position 1 of the tray. 5. Place a 6 ml C18-E cartridge in position 1 of the carousel.
Increase Throughput and Recoveries for EPA Method 508.1 with Automated Extraction using Strata C18-E SPE Cartridges and Zebron ZB-MultiResidue GC Columns Kali Tudela Phenomenex, Inc., 411 Madrid Ave.,
More informationThe Design of High Temperature Capillary Gas Chromatography Columns Based on Polydimethylsiloxane
The Design of High Temperature Capillary Gas Chromatography Columns Based on Polydimethylsiloxane Jarl Snider, D. J. Hotnisky, Kristi Sellers, Dinesh V. Patwardhan Ph. D. Restek Corporation www.restekcorp.com
More informationThe Suite for Environmental GC Analysis
The Suite for Environmental GC Analysis SGE Environmental GC Columns Performance Selectivity Delivery Promise www.sge.com SGE Environmental GC Columns The Suite for Environmental GC Analysis SGE GC Columns
More informationDetection of Environmental Contaminants Caused by the Oil Spill in the Gulf of Mexico by GC and Hplc
Detection of Environmental Contaminants Caused by the Oil Spill in the Gulf of Mexico by GC and Hplc Sky Countryman, Ngoc Nguyen, Jeff Layne, Kory Kelly, and Zeshan Aqeel Phenomenex, Inc., 411 Madrid Ave.,
More informationSo Many Columns! How Do I Choose? Daron Decker Chromatography Technical Specialist
So Many Columns! How Do I Choose? Daron Decker Chromatography Technical Specialist GC Columns Wall Coated Open Tubulars Liquid phase coated capillaries Internal Diameter 0.05 0.53mm Length 5m 100m Porous
More informationviridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis
[ viridis columns ] viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis Supercritical Fluid Chromatography (SFC)
More informationThe Use of Tandem Quadrupole GC/MS/MS for the Determination of Polycyclic Aromatics Hydrocarbons (PAHs) in Food Products
The Use of Tandem Quadrupole GC/MS/MS for the Determination of Polycyclic Aromatics Hydrocarbons (PAHs) in Food Products Bruno Veyrand, Aline Brosseaud, Philippe Marchand, Fabrice Monteau, François Andre,
More informationHICHROM. Chromatography Columns and Supplies. LC COLUMNS Vydac. Catalogue 9. Hichrom Limited
HICHROM Chromatography Columns and Supplies LC COLUMNS Vydac Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk
More informationSample Pre-Treatment : Introduction to Commonly Used Techniques for Gas
Sample Pre-Treatment : Introduction to Commonly Used Techniques for Gas Chromatography Joan Stevens, Ph.D. Sample Preparation Applications Scientist Chemistries and Supplies Division 1 October 27, 2011
More informationHypersil BDS Columns TG 01-05
TG 0-0 Hypersil BDS Columns Introduction Hypersil BDS columns have gained a reputation over the years as one of the most robust, reproducible and reliable HPLC column brands available. This Technical Guide
More information[ Care and Use Manual ]
Oasis HLB DISKS I. Introduction Oasis HLB is a Hydrophilic-Lipophilic-Balanced, water-wettable, reversed-phase sorbent for all your SPE needs. It is made from a specific ratio of two monomers, the hydrophilic
More informationThermo Scientific Accucore XL HPLC Columns. Technical Manual
Thermo Scientific Accucore XL HPLC Columns Technical Manual Thermo Scientific Accucore XL HPLC Columns Based on Core Enhanced Technology using µm solid core particles, Accucore XL HPLC columns allow users
More informationPut the. C18 aside. and take a look... Reasons. to try the. NEW Gemini C6-Phenyl
Put the C18 aside and take a look... 6 Reasons to try the EW Gemini Reason #6 ALTERATE SELECTIVITY to your C18 Column Adding to your method development options, Gemini offers additional polar and aromatic
More informationAnalysis of Polycyclic Aromatic Hydrocarbons in Soil with Agilent Bond Elut HPLC-FLD
Analysis of Polycyclic Aromatic Hydrocarbons in Soil with Agilent Bond Elut HPLC-FLD Application Note Environmental Authors Bellah O. Pule, Lesego C. Mmualefe, Nelson Torto Department of Chemistry Rhodes
More informationSample Preparation Method Development for Complex Matrices Such as Foods by QuEChERS and Solid Phase Extraction (SPE)
APPLICATINS Sample Preparation Method Development for Complex Matrices Such as Foods by QuEChERS and Solid Phase Extraction (SPE) Sueki Leung, Erica Pike, and Allen Misa Phenomenex, Inc., 411 Madrid Ave.,
More informationTest Report. Report No. ECL01H Page 1 of 5
Report No. ECL01H067809002 Page 1 of 5 Applicant Address LITE-ON MICROELECTRONICS (WUXI) CO., LTD. LITE-ON SEMICONDUCTOR CORP. LAND LOT J7 J8WEPZ, NEW DISTRICT, WUXI CITY, JIANGSU, CHINA 9F,NO.233-2 PAO-CHIAO
More informationMeeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS
Application Note # CA 284780 Meeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS Abstract The analysis of semi-volatile organic compounds
More informationThermo Scientific HyperSep Dispersive SPE Products. Efficient sample preparation and clean-up using the QuEChERS Method
Thermo Scientific HyperSep Dispersive SPE Products Efficient sample preparation and clean-up using the QuEChERS Method The QuEChERS method overcomes the problems associated with time consuming, expensive
More informationChoosing the Correct GC Column Dimensions and Stationary Phase
Choosing the Correct GC Column Dimensions and Stationary Phase Daron Decker Chromatography Technical Specialist Page 1 Nothing is useless it can always serve as a bad example Custom Column: 150 m x 250
More informationFast and Accurate Analysis of PBDEs in a Single Run, Including BDE-209
Fast and Accurate Analysis of PBDEs in a Single Run, Including Kory Kelly, Xianrong (Jenny) Wei, and Matthew Trass Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 90501 USA PO16570913_W_2 PO14400613_W_2
More informationPhenyl-Hexyl. UHPLC Columns. Alternate, complementary selectivity to C18 and C8 bonded phases
Phenyl-Hexyl UHPLC Columns Alternate, complementary selectivity to C8 and C8 bonded phases Particularly recommended for compounds containing aromatic groups Excellent bonded phase stability for durable,
More informationFast and Accurate Analysis of PBDEs in a Single Run, Including
Fast and Accurate Analysis of PBDEs in a Single Run, Including Kory Kelly, Adam Endeman, and Matthew Trass Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 90501 USA PO14700713_2 PO14400613_W_2 Abstract
More informationEnhance Resolution FOR POLYMER ANALYSIS, Guaranteed *
Enhance Resolution FOR POLYMER ANALYSIS, Guaranteed * Remarkable Reproducibility Exceptional Efficiency Long Lifetimes Economically Priced www.phenomenex.com/phenogel Phenogel Non-Aqueous GPC/SEC Columns
More informationThe BIG GC Special. Details, Playoff Specials, and Early Bird Discounts Inside! Expires: December 20, 2013 Mention Offer Code: ZBNF1213.
The BIG GC Special Details, Playoff Specials, and Early Bird Discounts Inside! Exclusive Savings on Zebron GC Columns for any phase new to your company* Length 10-15 Meter 30 Meter 60 Meter Sale Price
More informationLC Technical Information
LC Technical Information Method Transfer to Accucore.6 μm Columns Containing solid core particles, which are engineered to a diameter of.6μm and a very narrow particle size distribution; Accucore HPLC
More information35 % OFF HPLC. The Ultimate Guide to
The Ultimate Guide to HPLC Reversed Phase Selectivity 5 % FF Your Perfect Column Expires: 0 November 0 Promo Code: RPNV *ffer applies to products listed in this brochure and for columns with ID less than
More informationAndrei Medvedovici, Florina Micăle, Florentin Tache
Andrei Medvedovici, Florina Micăle, Florentin Tache Department of Analytical Chemistry, Faculty of Chemistry, University of Bucharest, # 90-92 Panduri Ave., Bucharest-050663, Romania; Fax no. + 40214102279;
More informationProduct Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns
Product Bulletin HPLC Columns ACE LC/MS and Rapid Analysis HPLC Columns 0 mm, 30 mm, 35 mm and 50 mm column lengths.0,., 3.0, 4.0 and 4.6 mm column diameters Configured for High Sample Throughput Specially
More informationThis project has been funded with support from the European Commission. This publication reflects the views only of the authors, and the Commission
This project has been funded with support from the European Commission. This publication reflects the views only of the authors, and the Commission cannot be held responsible for any use which may be made
More informationSemivolatile Organics Analysis Using an Agilent J&W HP-5ms Ultra Inert Capillary GC Column
Semivolatile Organics Analysis Using an Agilent J&W HP-5ms Ultra Inert Capillary GC Column Application Note Environmental Author Doris Smith and Kenneth Lynam Agilent Technologies, Inc. 285 Centerville
More informationIN QUALITATIVE ANALYSIS,
IN QUALITATIVE ANALYSIS, YOU VE ALWAYS HAD TO CHOOSE BETWEEN ACCURACY AND THROUGHPUT. NOW THERE S NO REASON TO ever have to. WATERS QUALITATIVE ANALYSIS solutions Waters ACQUITY UPLC System with the Waters
More information3 Ways To Choose. All GC 5 Phases Are Not The Same! ZB-5. ZB-5MSi. ZB-5HT Inferno. ZB-5ms ZB-5MSPLUS. ZB-SemiVolatiles.
3 Ways To Choose All GC 5 Phases Are Not The Same! ZB-5 ZB-5M ZB-5HT Inferno ZB-5ms ZB-5MSPLUS ZB-SemiVolatiles www.phenomenex.com/5phase Choosing Your 5 Phase Is Easy Use the NEW GC Column Finder web
More informationFaster Semivolatiles Analysis with a Scaled- Down Method and GC Accelerator Kit
Faster Semivolatiles Analysis with a Scaled- Down Method and GC Accelerator Kit Analysis times for semivolatile compounds can limit sample throughput and decrease overall lab productivity. You can significantly
More informationNew 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns
New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns have: the highest plate number versus any other 5-micron
More information[ OSTRO PASS-THROUGH SAMPLE PREPARATION PRODUCT ] The Simpler Way to Cleaner Samples
[ OSTRO PASS-THROUGH SAMPLE PREPARATION PRODUCT ] The Simpler Way to Cleaner Samples SIMPLE EASY EFFICIENT DEPENDABLE 2 waters.com/ostro 3 SIMPLE The Ostro Pass-Through Sample Preparation Product provides
More informationSUPPLEMENTARY INFORMATION. Towards streamlined identification of dioxin-like compounds in
SUPPLEMENTARY INFORMATION Towards streamlined identification of dioxin-like compounds in environmental samples through integration of suspension bioassays Xiao, Hongxia # ; Brinkmann, Markus # *; Thalmann,
More informationExploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis
Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis A. Caruso, M. Santoro, P. Magni, S. Pelagatti, and R. Facchetti Thermo Fisher Scientific, Milan,
More informationComparison of Solid Core HPLC Column Performance: Effect of Particle Diameter
Comparison of Solid Core HPLC Column Performance: Effect of Particle Diameter Luisa Pereira, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20755 Key Words Solid core, fused core, superficially
More informationThe Role of the Carbon Cartridge in the One-Pass System
The Role of the Carbon Cartridge in the One-Pass System William Jones and Zoe Grosser, Horizon Technology, Inc. Key Words Solid phase extraction, spe, one-pass system, carbon cartridges Introduction Horizon
More informationenvironmental Rtx -CLPesticides and Rtx -CLPesticides2 Columns: The Ideal Confirmational Pair for Analyzing Polychlorinated Biphenyls (PCBs)
environmental #59120 Applications note Rtx -CLPesticides and Rtx -CLPesticides2 Columns: The Ideal Confirmational Pair for Analyzing Polychlorinated Biphenyls (PCBs) Polychlorinated biphenyls (PCBs) are
More informationAppNote 2/2000. Stir Bar Sorptive Extraction (SBSE) applied to Environmental Aqueous Samples
AppNote 2/2 Stir Bar Sorptive Extraction (SBSE) applied to Environmental Aqueous Samples Pat Sandra Department of Organic Chemistry, University of Gent, Krijgslaan 281 S4, B-9 Gent, Belgium Erik Baltussen
More informationEnsure reproducible Polymeric SPE workflow for high-throughput bioanalysis applications
Ensure reproducible Polymeric SPE workflow for high-throughput bioanalysis applications Agilent Bond Elut Plexa vs. Waters Oasis Sample Prep Products Reliability is a key parameter in developing rugged,
More informationReviewing Material Safety Data Sheets to Verify Significant Drinking Water Threats
Reviewing Material Safety Data Sheets to Verify Significant Drinking Water Threats 1 INTRODUCTION When attempting to verify the existence of a Significant Drinking Water Threat (SDWT) related to the handling
More informationLC-MS/MS Method for the Determination of Diclofenac in Human Plasma
LC-MS/MS Method for the Determination of Diclofenac in Human Plasma J. Jones, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 20569 Key Words SPE, SOLA, Accucore RP-MS, diclofenac, Core
More informationAPPENDIX D Laboratory Analytical Reports
Allied Aviation Initial Abatement Report, Arlington, VA December 4, 2015 Amec Foster Wheeler Project 37650016 APPENDIX D Laboratory Analytical Reports #=CL# LIMS USE: FR - JOHN MITTAUER LIMS OBJECT ID:
More informationAppendix 1: Polycyclic Aromatic Compounds: Nomenclature and Analysis
Appendix 1: Polycyclic Aromatic Compounds: Nomenclature and Analysis This appendix provides an explanation for and definition of the terms that have been used to describe polycyclic aromatic compounds.
More informationIncreasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer
Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer Olaf Scheibner and Maciej Bromirski Thermo Fisher Scientific, Bremen, Germany Overview Purpose: Improve the performance
More informationExperience the Zebron Difference
Experience the Zebron Difference Premier GC Column Selection Guide www.phenomenex.com/gc Introducing the Zebron Experience Proven Performance Zebron GC columns are engineered by expert Phenomenex GC scientists
More information40 % OFF. Upgrade to Zebron GC Columns. Equivalent Selectivity. Better Service. ZB-1ms ZB-5 ZB-624. ZB-5ms ZB-WAX ZB-1.
Upgrade to Zebron GC Columns Equivalent Selectivity. Better Service. ZB-ms ZB-5 ZB-64 ZB- 40 % OFF Zebron GC columns ZB-WAX ZB-5ms * Expires: October 30, 009 Please Mention Offer Code: ZBE009 * Offer applies
More informationSupporting Information
1 Supporting Information 2 3 4 5 6 7 8 9 1 11 12 13 14 MANUSCRIPT TITLE: AUTHORS: ADDRESS: Sediment Records of Polycyclic Aromatic Hydrocarbons (PAHs) in the Continental Shelf of China: Implications for
More informationA Look at Column Choices. Ed Kim Application Engineer Agilent Technologies, Inc February 12, 2009
A Look at Column Choices Does one-size-fit-all? Ed Kim Application Engineer Agilent Technologies, Inc February 12, 2009 Seminar utline lica Surface Chemistry & Physical Characteristics ti lica Bonding
More informationUltra-Inert chemistry for Trace Level Analysis
Ultra-Inert chemistry for Trace Level Analysis Cikui Liang, Ph.D. Challenges and Needs of Today s Laboratories Challenges Qualification/quantification of trace samples Keep instrument up and running Needs
More informationEvaluation of Several Columns and Solvents for Post-Extraction Gel Permeation Chromatography (GPC) Clean-up of Fish Tissue Prior to PCB Analysis
Evaluation of Several Columns and Solvents for Post-Extraction Gel Permeation Chromatography (GPC) Clean-up of Fish Tissue Prior to PCB Analysis Keywords: Automated GX-271 GPC Clean-up System, Contaminants,
More informationFORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION
FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION A purpose-built collection of the best-inclass components for forensic toxicology Whether you re challenged to present reliable and secure forensic sample
More informationMethod 8270C PAH. FD- Field Duplicate Samples
Mr. John Rendall Maine Yankee 321 Old Ferry Road Wiscasset, Maine 04578 RE: Project No.: Maine Yankee Sediment Samples Lab Name: Katahdin Analytical Services, Westbrook, Maine Site Name: Maine Yankee Nuclear
More informationFacility: Mansfield Revision 3. Title: PAHs by SPME Page 1 of 11
Title: PAHs by SPME Page 1 of 11 Determination of Parent and Alkyl Polycyclic Aromatics in sediment Pore Water Using Solid-Phase Microextraction and Gas Chromatography/Mass Spectrometry in Selected Ion
More informationTETRA TECH, INC. December 8, Lynn Nakashima Berkeley Regional Office 700 Heinz Avenue, Suite 200C Berkeley, California 94710
TETRA TECH, INC. December 8, 2014 Lynn Nakashima Berkeley Regional Office 700 Heinz Avenue, Suite 200C Berkeley, California 94710 Subject: LBNL Fiber Optic Distributed Acoustic Sensor (DAS) Survey Sampling
More informationAnalysis of Semivolatile Organic Compounds Using the Agilent Intuvo 9000 Gas Chromatograph
Analysis of Semivolatile Organic Compounds Using the Agilent Intuvo 9 Gas Chromatograph Application Note Author Matthew Giardina, Ph.D., Applications Chemist, Gas Phase Separations Division, Agilent Technologies,
More informationApplication of an Analytical Technique for Determining Alkyl PAHs, Saturated Hydrocarbons and Geochemical Biomarkers
Application of an Analytical Technique for Determining Alkyl PAHs, Saturated Hydrocarbons and Geochemical Biomarkers Chuck Neslund, Manager Specialty Services National Environmental Monitoring Conference
More informationPolycyclic Aromatic Hydrocarbons in Water by GC/MS PBM
Organics Revision Date: July 10, 2017 Polycyclic Aromatic Hydrocarbons in Water by GC/MS PBM Parameter Analytical Method Introduction Method Summary MDL(s) and EMS Analyte Codes Polycyclic Aromatic Hydrocarbons
More informationAPPENDIX A TO PART 136 METHODS FOR ORGANIC CHEMICAL ANALYSIS OF MUNICIPAL AND INDUSTRIAL WASTEWATER METHOD 610 POLYNUCLEAR AROMATIC HYDROCARBONS
APPENDIX A TO PART 136 METHODS FOR ORGANIC CHEMICAL ANALYSIS OF MUNICIPAL AND INDUSTRIAL WASTEWATER METHOD 610 POLYNUCLEAR AROMATIC HYDROCARBONS 1. Scope and Application 1.1 This method covers the determination
More informationILLA SpA VIA GHISOLFI GUARESCHI, NOCETO (PR)
FOOD PACKAGING MATERIALS FOOD CONTACTS 1265\FPM\FDC\15 12/11/2015 1 ILLA SpA VIA GHISOLFI GUARESCHI, 1 43015 NOCETO (PR) D.P.R. dated 23/08/1982, D.L. 108 dated 25/01/1992, D.M.34 dated 21/3/3 European
More informationLC800. Smart HPLC. Until now UHPLC From now Smart HPLC
LC800 Smart HPLC Until now UHPLC From now Smart HPLC Smart HPLC Leads to Ultimate Performance Patent Pending S LC800 is a completely new and unique concept, designed for maximum performance in high resolution
More informationFast Protein and Peptide Separations Using Monolithic Nanocolumns and Capillary Columns
Application Note 3 Fast Protein and Peptide Separations Using Monolithic Nanocolumns and Capillary Columns INTRODUCTION Polymeric monolithic stationary phases offer an alternative to the classical microparticulate
More informationBringing uhplc Performance to the Separation of Peptides
P e p t i d e E S - C 1 8 U H P L C C o l u m n s Bringing uhplc Performance to the Separation of Peptides Compatible with UHPLC and conventional HPLC equipment. Sumpfstr. 3, CH-6300 Zug; Fax: 041 748
More informationHPLC Winter Webinars Part 2: Sample Preparation for HPLC
HPLC Winter Webinars Part 2: Sample Preparation for HPLC Jon Bardsley, Application Chemist Thermo Fisher Scientific, Runcorn/UK The world leader in serving science What am I Going to Talk About? What do
More informationGet Selective. By Jaap de Zeeuw
34 Get Selective Modern narrow bore columns have made chromatographers lazy when it comes to stationary phase selection. Here s how getting back to basics in gas chromatography by using selectivity can
More informationLow Bleed Stationary Phases for Gas Chromatography
Low Bleed Stationary Phases for Gas Chromatography Slide 4 Advantages of Low Bleed Phase Lower bleed compared to standard phases Better signal to noise (sensitivity) Higher upper temperature - shorter
More informationEnvironmental Forensic Principals for Sources Allocation of Polycyclic Aromatic Hydrocarbons
Investigate Integrate Innovate Environmental Forensic Principals for Sources Allocation of Polycyclic Aromatic Hydrocarbons October 2008 Presented by: Gwen O Sullivan, Erik Martin and Court D. Sandau Presentation
More information