Current and Voltage Transformer

Size: px
Start display at page:

Download "Current and Voltage Transformer"

Transcription

1 Digital Electric& Electronics System KS C Current and Voltage Transformer PHSE CURRENT TRNSFORMER PROTECTION CURRENT TRNSFORMER SQURE TYPE CURRENT TRNSFOMER (.KV) ROUND TYPE CURRENT TRNSFORMER [.KV] WINDING TYPE CURRENT TRNSFORMER [.KV] PHSE VOLTGE TRNSFORMER VOLTGE TRNSFORMER ND GROUNDING VOLTGE TRNSFORMER [0.7KV] EPOXY RESIN INSULTOR [0.KV] EPOXY RESIN INSULTOR [7., KV] EPOXY RESIN INSULTOR [, KV] SHUNT [VOLTGE DROP MV] CURRENT LIMIT RESISTER [CLR] CT, VT (0.kV, 7.kV, kv, kv, kv)

2 PHSE CURRENT TRNSFORMER Feature phase in one current transformer with combined each of ct easy to install, save the cost Case : Polycarbonate (PC) Rating Items Max. Voltage Frequency Phase Over Current Factor pplied range V Hz.0% ~.0%, 0In/Sec 0In/Sec V Window C.T (PW C.T) Specification Model DW-0 DW- DW- DW- DW- Pri. Cur.() Sec.Cur.() (%).0.0 /.0.0 / Burden(V). / / / 0 / 0 MCCB&ELCB F F F 00F 0/0F V Window C.T (PW C.T) Specification Model DW-0 DW- DW- DW- DW- Pri. Cur.() Sec.Cur.() (%).0.0 /.0.0 / Burden(V). / / / 0 / 0 MCCB&ELCB F F F 00F 0/0F DEESYS TOTL PRODUCTS GUIDE

3 External wiring diagram nd connection method Notice : pay attention of polar nd connection method Notice : pay attention of polar Unite : mm PW C.T DW-0 DW- DW- DW- DW- PW C.T DW-0 DW- DW- DW- DW- 7 B C 7 0 D 9 0 E 9 F 0 T 7 T H G DEESYS TOTL PRODUCTS GUIDE

4 PROTECTION CURRENT TRNSFORMER DS - R, DS - R, DS - R, DS - R [DS - R], DS - R Model st Rating nd Rating n In Frequency Burden DS - R ~00 n > 0 Va DS - R ~0 n > 0 ~0Va DS - R DS - R [DS - -R] 0~,0,000~,000 C / P n > 0 n > 0 n > 0 n > 0 0 in / Hz ~0Va Va ~0Va ~Va DS - R,0~,000 n > 0 n > 0 ~0Va ~Va Feature Tolerance class Overcurrent numeric(n) Safety Index Overcurrent intensity Rating burden Limit value of nd current when connect rating burden to c.t and input rating current P / P [ JEC0 ], P / 0P [ IEC0- ] In put over current on c.t and display has numeric of st rating current with the value which is overcurrent satisfied to tolerance class of nd current is divied by st rating current. [ n > / n > 0 / n > 0 ] In put over current on c.t and display has numeric of st rating current with the value which is overcurrent get out of tolerance class is divied by st rating current. [ FS / FS 0 / FS / FS 0 / FS 0 ] In put over current on st c.t and display as numeric of st rating current for max overcurrent value with no change in thermal and mechnical [ 0In / 7In / In / In ] In = rated current Total load value to connect nd. Within allowance range of tolerance class in c.t V / 0V / V / V / 0V [ JEC0 ].V / V / 0V / V / 0V [ IEC0- ] Uite : m/m MODEL B C D DS-R DS-R DS-R 0 DS-R 0 DS--R 0 DS-R 7 DEESYS TOTL PRODUCTS GUIDE

5 SQURE TYPE CURRENT TRNSFOMER (.KV)PNEL DS-, DS-, DS-, DS-, DS-, DS- BUsbar through type Color : Brown For metering Resin : BS Non-flamable(case) For indoor Mold : Polyester Single ratio C.T DS- DS- DS- DS- DS- DS- Primary () ~ ~ 00 0~0 0~0 7~0 0~000 0~00 Secondary () or Burden (V) or or or or ~0 ~0 0 (%) over curr. strenght (times) or Frequency (Hz) / Weight (kg) Unit : mm DS- DS- DS- DS- DS- DS-- DS B C 0 D Double C.T Connection diagram DS CT is designed how to install the busbar is very easy by being used the installing metal. DEESYS TOTL PRODUCTS GUIDE 7

6 ROUND TYPE CURRENT TRNSFOMER (.KV) DR-, DR-, DR-, DR- Cable through type Mounting parts to be changeable at 90 direction For metering application For indoor Color : Brown Resin : BS Non-flamable(case) Mold : Polyester What is rating ampere turn? Specification The rating.t is the value of rating ry current() a multiplies the turn of ry conductor. ccording to the method how the turn of ry conductor is changed. It is able to change rating ry current. ex) In case of rating T : T The turn of cable T :rating ry current The turn of cable T :rating ry current The turn of cable T :rating ry current Refer to page for the turn and cross area of ry conductor according to rating ry current. DR- DR- DR- DR- 9 0 B 77 øc 7 0 ød 7 E F G DR- DR- Rated (T) Burden (V) or (%).0.0 Over Current Strength (times) 0ln Frequen -cy(hz) / Weight (kg) 0. DR or DR DEESYS TOTL PRODUCTS GUIDE

7 KSC- Current ratio and across area of ry conductor ccording to turn of DR. CT ry conductor Follwing table is discribed the trun rating ry current, ry conductor and the cross area of 0V vinyl wire(00.i Wire) The allownace current of wire is the value at amboent temperaure 0 discribed. V V 0V DR- / DR- DR- DR- Rated T ry current () turns (T) ry cable (mm ) Rated T ry current () turns (T) ry cable (mm ) Rated T ry current () turns (T) ry cable (mm ) ( ) ( ) ( ) X( ) X( ) X( ) X( ) 0 7 (ex)in case of DR-type CT and trun of mm outer cross lengh of mm will. mm The error 0 & T is 0. class and then inner cross lengh of DP-F CT is 7mm and the CTcan be used DEESYS TOTL PRODUCTS GUIDE 9

8 WINDING TYPE CURRENT TRNSFOMER (.KV) DRW-, DRW-0, DRB-, DRB- Winding type Color : Brown For metering Resin : BS Non-flamable(case) For watt hour meter Mold : Polyester Changeable 90 at mounting direction Single ratio C.T DRW- DRB- DRW- DRB- Primary () ~0 0~ ~ 00~0 ~0 0v ~ 00~0 dimension Secondary() or or Burden (V) 0 (%).0.0 over curr. strenght (times) 0in 0in Fig Fig Fig Fig Weight (kg) Remark Terminal Busbar Terminal Busbar DRW C.T DRB C.T Fig.~0(DRW C.T) Fig. 0~0(DRB C.T) DRW- DRW-0 Primary curreent ~0 Unit : mm B C 90 0 C DRB- DRB- Primary curreent() 0~ ~ 00~0 0~ ~ 00~0 B C D E F G.. H(ø) DEESYS TOTL PRODUCTS GUIDE

9 PHSE VOLTGE TRNSFORMER Feature phase measuring pt is very good shape throagh landmark design and easy to install price is less expensive and ecomomical to apply to SWGR Simple for wiring and reduce the time for connection Rating Items Max. Voltage Frequency Phase Over Voltage Factor pplied range V Hz.0%.Vn Conlnuous Specification Model DP-F (PW) DGP-F (PW) Pri. Volt 0-0V 0/R-0/R Sec. Volt 0-0V 90/RV (%).0.0 Burden V V DEESYS TOTL PRODUCTS GUIDE

10 PHSE VOLTGE TRNSFORMER External wiring diagram nd Terminal cover st Terminal and Fuse cover DEESYS TOTL PRODUCTS GUIDE

11 VOLTGE TRNSFORMER ND GROUNDING VOLTGE TRNSFORMER (0.7KV) Single phase metering & relaying For indoor Color : Brown Resin : BS Non-flamable(case Mold : Epoxy Note: It the burden of ry winding open terinal is less than rating burden. It may be the reason of relay malfunction due to remaining voltage. Please select the pit that applieable burden of PT will be % of rating burden. Specification Name Rated voltage(v) ccuracy Burden(V) 'ry 'ry 'ry 'ry 'ry 'ry 'ry Frequency (Hz) Voltage Factor (IEC-) Weight (kg) V.T DP- DP-F DP- DP-F DP- DP-F or 90 0r Vh cont... DGP- DGP-F.0 /. GPT DGP- DGP-F DGP-T DGP-TF DGP-T DGP-TF 0/ / 0/ 90/ or 0/ 90/ or 0/ p.vh cont.9vh 0S... Model DP- DP-/DGP- DP-/DGP- B 0 C 0 7 D 7 7 E 77 7 DEESYS TOTL PRODUCTS GUIDE

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -A - Introduction - Thank for your purchasing MITSUBISHI ELECTRIC MELPRO TM D Series Digital Protection

More information

TURQUOISE SWITCHES V TYPE (ABV)

TURQUOISE SWITCHES V TYPE (ABV) HIGH ENVIRONMENTAL RESISTANCE TURQUOISE SWITCHES V TYPE (ABV) FEATURES Miniature size (33 15.9.3 mm) (99.626.406 inch) Sealed construction for use in adverse environment Sealed construction by epoxy resin

More information

Effect of core balance current transformer errors on sensitive earth-fault protection in compensated MV networks

Effect of core balance current transformer errors on sensitive earth-fault protection in compensated MV networks 24th International Conference & Exhibition on Electricity Distribution CIRED) 12-15 June 2017 Session 3: Operation, control and protection Effect of core balance current transformer errors on sensitive

More information

EE301 RESISTANCE AND OHM S LAW

EE301 RESISTANCE AND OHM S LAW Learning Objectives a. Describe the concept of resistance b. Use Ohm s law to calculate current, voltage, and resistance values in a circuit c. Discuss the difference between an open circuit and a short

More information

Single Core XLPE/LSF/AWA/LSF Power Cable

Single Core XLPE/LSF/AWA/LSF Power Cable Single Core XLPE/LSF/AWA/LSF Power Cable 00/00V and 100/00V Application LSF insulated, armoured and sheathed, single core power cable for use in fixed installations. Especially for use in areas where fire

More information

Digital Current Transducer HO-SW series I P N = A. Ref: HO 100-SW; HO 150-SW; HO 200-SW; HO 250-SW

Digital Current Transducer HO-SW series I P N = A. Ref: HO 100-SW; HO 150-SW; HO 200-SW; HO 250-SW Digital Current Transducer HO-SW series I P N = 100... 250 A Ref: HO 100-SW; HO 150-SW; HO 200-SW; HO 250-SW Bitstream output from on onboard Sigma Delta modulator. For the electronic measurement of current:

More information

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER CAUTION: This equipment is designed for connection to mains voltages and must be used in accordance with this guide. If it is not, the safety protection

More information

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22 .1 Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + C - nllk 09 18 W - 58 W for Zone and The lighting solution for high temperatures up to C The linear luminaires series nllk

More information

Electrical Machines-I Prof. D. Kastha Department of Electrical Engineering Indian Institute of Technology, Kharagpur

Electrical Machines-I Prof. D. Kastha Department of Electrical Engineering Indian Institute of Technology, Kharagpur Electrical Machines-I Prof. D. Kastha Department of Electrical Engineering Indian Institute of Technology, Kharagpur Lecture - 20 Potential and Current Transformers (Refer Slide Time: 00:37) So far we

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer LDSR 0.3-TP/SP1 I P R N = 300 ma For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Closed

More information

H07RN-F. Flexible Cables and Cords 60 C 450/750 V. Application. Specifications

H07RN-F. Flexible Cables and Cords 60 C 450/750 V. Application. Specifications H0RN-F 0 C 0/0 V Application For mains supply or extension leads for portable or fixed equipment operating indoors or outdoors (domestic or industrial) under conditions of frequent handling trailing or

More information

Non-Contact Safety Systems CMS

Non-Contact Safety Systems CMS Selection table for non-contact safety system // Evaluation units Connection Desi Read head contact assembly Assured switch-on distance S ao [mm] Assured switch-on distance S ar [mm] Number of outputs

More information

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows: The basic PC software is supplied free with the recorder. There is an additional charge for the extensive Data Acquisition Software supplied with communication of RS-232/422/485 or Ethernet. The Ordering

More information

THF / 1SCC330001M THF 1S1 C

THF / 1SCC330001M THF 1S1 C THF 2247 0191/ 1SCC330001M5803 34 THF 1S1 C Installation and Operation Instruction for THF Filter and Protective Unit THF 1_ THF 1S_ THF 1BS_ General guidelines Due to the fact that most UK building earth

More information

Thermal-Magnetic Circuit Breaker 2210-T2...

Thermal-Magnetic Circuit Breaker 2210-T2... Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring

More information

Microprocessor Based Characteristics and adjustments

Microprocessor Based Characteristics and adjustments Microprocessor Based Characteristics and adjustments 7- Range Operation Settings Operation and Examples 0 Ground Fault and Pre-rip larm LED ndication and OCR Controller ime/current Curves - OCR Checker

More information

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER ISOCON-6 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting

More information

CS Series. Capacitance Type. Type. Proximity Sensor. Features

CS Series. Capacitance Type. Type. Proximity Sensor. Features INFORMATI Series Features Capacitance Type - Metal cylinder/resin cylinder/square type - Non-metal objects such as wood, paper, plastic and water can be detected. - The operating distance is adjustable

More information

All part numbers in the coding below start with "TC-" and end with "203"

All part numbers in the coding below start with TC- and end with 203 1. Scope: This specification for approval relates to 2. Type designation: The type designation shall be in the following form : All part numbers in the coding below start with "TC-" and end with "203"

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer HO-NSM series I PN = 8, 15, 25 A Ref: HO 8-NSM, HO 15-NSM, HO 25-NSM For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the

More information

NYY-J/-o 34 NYCWY 36 NYCY 37 NAYY 38

NYY-J/-o 34 NYCWY 36 NYCY 37 NAYY 38 NYY-J/-o 34 NYCWY 36 NYCY 37 NAYY 38 NYY-J/-O Energy and control cable acc. to DIN VDE 0276 and HD 603 Application Indoor and outdoor installation, laying in ducts and underground, for power stations,

More information

LV-MV INSULATORS INSULATORS

LV-MV INSULATORS INSULATORS LV-MV INSULATORS LV-MV INSULATORS CONTENTS LOW VOLTAGE & MEDIUM VOLTAGE INSULATORS 0 0 0 0 0 0 0 0 /0 LV Insulators type SK LV Insulators type SR LV Insulators type RD LV Insulators type DS LV Insulators

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer HO-NP/SP33 series I PN = 8, 15, 25 A Ref: HO 8-NP/SP33, HO 15-NP/SP33, HO 25-NP/SP33 For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the

More information

INSULATORS INSULATORS

INSULATORS INSULATORS INSULATORS INSULATORS INSULATORS CONTENTS > INDOOR INSULATORS 0 /02 Post Insulators 03 /04/0 Capacitive Divider Insulators 0 Wall Bushings /07 08 Bolt Bushings /0 GENERAL INFORMATION ON INSULATORS Rated

More information

SUPPLY, ERECTION & COMMISSIONING OF 2 X 3.15 MVA 33/11KV SUB-STATION at Khuntlipalli,Bargarh ( PACKAGE - B )

SUPPLY, ERECTION & COMMISSIONING OF 2 X 3.15 MVA 33/11KV SUB-STATION at Khuntlipalli,Bargarh ( PACKAGE - B ) SUPPLY, ERECTION & COMMISSIONING OF 2 X 3.15 MVA 33/11KV SUB-STATION at Khuntlipalli,Bargarh ( PACKAGE - B ) Sl. 1 2 Description of Work Supply,Erection & Commissioning of 2 x 3.15 MVA, New 33/11 KV Primary

More information

E8EB-N0C2B E8EB-N0B2B

E8EB-N0C2B E8EB-N0B2B Slim Sensor CSM DS_E 1 Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree

More information

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008 LV HRC fuse links Overview LV HRC fuses are used for installation systems in non-residential, commercial and industrial buildings as well as in switchboards of power supply companies. They therefore protect

More information

Sealing possibility Electrical endurance (ops) Mechanical endurance (ops) Overvoltage category Standards

Sealing possibility Electrical endurance (ops) Mechanical endurance (ops) Overvoltage category Standards Miniature circuit breaker ETIMAT 7,7 0.5 Rated voltage Rated current Rated frequency Rated short-circuit capacity Energy limiting class characteristic Build-in width Mounting on the rail 0/00 V AC, max.

More information

SPECIFICATION. WRITTEN by 06/28. DONG IL ELECTRONICS CO., LTD. ( Head Offics & Manufacture : Korea )

SPECIFICATION. WRITTEN by 06/28. DONG IL ELECTRONICS CO., LTD. ( Head Offics & Manufacture : Korea ) Messrs: Ropla Issued date : 2017.06.28 Part Description : Type DS (Safety standard Recognized Ceramic Capacitor) Customer Part No DONG IL Part No - DS Series DONG IL CUSTOMER WRITTEN by CHECKED by APPROVED

More information

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -C - Safety section - This Safety section should be read before starting any work on the relay.

More information

Type Function Output config. Auxiliary Case Page

Type Function Output config. Auxiliary Case Page Transducers CONTENTS Page Transducer Survey....4 General description and technical data...8 Transducers DU for AC voltage....12 Transducers DI for AC current....16 Transducers DUD for DC voltage and DID

More information

DPR User Manual. LG Digital Protection Relays

DPR User Manual. LG Digital Protection Relays DPR User Manual LG Digital Protection Relays DPR User Manual LG Digital Protection Relays Contents General descriptions 3 Features 3 Additional functions 4 Environmental characteristics 6 1. Overcurrent

More information

Calculation of the Current Transformer Accuracy Limit Factor. Application Note

Calculation of the Current Transformer Accuracy Limit Factor. Application Note Calculation of the Current Transformer Application Note 1MRS 755481 Issued: 09.11.2004 Version: Al09.11.2004 Calculation of the Current Transformer Application Note Contents: 1. Scope... 4 2. Introduction...

More information

Selecting the current rating for equipment

Selecting the current rating for equipment Selecting the current rating for equipment 1. Rated current: the maximum continuous load current. Short-time withstand current: thermal withstand current term term is given for 1s or 3s short circuit current

More information

ET 162 Circuit Analysis. Current and Voltage. Electrical and Telecommunication Engineering Technology. Professor Jang

ET 162 Circuit Analysis. Current and Voltage. Electrical and Telecommunication Engineering Technology. Professor Jang ET 162 Circuit Analysis Current and Voltage Electrical and Telecommunication Engineering Technology Professor Jang Acknowledgement I want to express my gratitude to Prentice Hall giving me the permission

More information

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS SUMMARY OF MODELS OF HRC FUSE-LINKS Type PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size

More information

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30 eries Features Best pressure transmission solution for small and middle sized project such as indoor heating and air conditioning, water and sewer, or incinerator, etc. Improves noise resistance and minimize

More information

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS PRODUCT SCIFICATIONS CUSTOMER : CUSTOMER'S REFERENCE : 3/34 3/35 3/36 Series DESCRIPTIONS : SHENGXIN TY : METALLIZED POLYESTER FILM CAPACITOR-BOX series Fig. w T T W H.5max P 20min H S L0.5max Fig Fig2.

More information

DATA RACK BUSBAR. Data Rack Busbar Systems A.

DATA RACK BUSBAR. Data Rack Busbar Systems A. Data Rack Busbar Systems 250...1000 A www.eae.com.tr Overview Overview To power the mission critical IT infrastructures on the Data Rack Cabinets, EAE offers a highly flexible and reliable Busbar System

More information

PHOENIX CONTACT - 04/2016. Features

PHOENIX CONTACT - 04/2016. Features Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.

More information

STATEWIDE CAREER/TECHNICAL EDUCATION COURSE ARTICULATION REVIEW MINUTES

STATEWIDE CAREER/TECHNICAL EDUCATION COURSE ARTICULATION REVIEW MINUTES STATEWIDE CAREER/TECHNICAL EDUCATION COURSE ARTICULATION REVIEW MINUTES Articulation Agreement Identifier: _ELT 107/ELT 108 (2011-1) Plan-of-Instruction version number (e.g.; INT 100 (2007-1)). Identifier

More information

Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000,

Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000, Digital Current Transducer HLSR-PW series I P N = 16... 50 A Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000, Bitstream output from on onboard Sigma Delta modulator. For the electronic measurement

More information

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol with PROFIBUS-PA procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application 00 II () G FISCO The SINEAX VK 66 is a temperature transducer for use in aumation systems

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer HO-NP series I P N = 4, 6, 12, 15 A Ref: HO 4-NP, HO 6-NP, HO 12-NP, HO 15-NP For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary

More information

Metal Oxide Film Resistors Axial Connections Metal Oxide Film Resistors 1/4W, 5% Components

Metal Oxide Film Resistors Axial Connections Metal Oxide Film Resistors 1/4W, 5% Components Metal Oxide Film Resistors Axial Connections Metal Oxide Film Resistors 1/4W, 5% Components High safety standard, high purity ceramic core Excellent non-flame coating Stable performance in diverse environment,

More information

Power system conductor volume calculation

Power system conductor volume calculation Power system conductor volume calculation Dr Audih alfaoury T&D power systems 2017-1018 Electrical Energy Engineering Department Dr Audih alfaoury 1 The transmission of electric power is carried at high

More information

SHREE DATTA SHETKARI SAHAKARI KARKHANA LTD. CHARITABLE TRUST SHREE DATTA POLYTECHNIC COLLEGE, DATTANAGAR CLASS TEST-01

SHREE DATTA SHETKARI SAHAKARI KARKHANA LTD. CHARITABLE TRUST SHREE DATTA POLYTECHNIC COLLEGE, DATTANAGAR CLASS TEST-01 SHREE DATTA SHETKARI SAHAKARI KARKHANA LTD. CHARITABLE TRUST SHREE DATTA POLYTECHNIC COLLEGE, DATTANAGAR CLASS TEST-01 Name of subject: Elect. & electronic Measurement Mark: 25 Institute Code: 1512 Subject

More information

Arduino Software: How long before my battery is dead?, version 2.4

Arduino Software: How long before my battery is dead?, version 2.4 Arduino Software: How long before my battery is dead?, version 2.4 By R. G. Sparber Protected by Creative Commons. 1 When powering an Arduino from a battery, it can be useful to be able to monitor available

More information

LO 1: Three Phase Circuits

LO 1: Three Phase Circuits Course: EEL 2043 Principles of Electric Machines Class Instructor: Dr. Haris M. Khalid Email: hkhalid@hct.ac.ae Webpage: www.harismkhalid.com LO 1: Three Phase Circuits Three Phase AC System Three phase

More information

American Zettler AZ742 RELAY Datasheet

American Zettler AZ742 RELAY Datasheet American Zettler AZ74 RELAY Datasheet http://www.manuallib.com/american-zettler/az74-relay-datasheet.html FEATURES Dielectric strength 000 Vrms Low height:.7 mm Epoxy sealed version available 0 Amp switching

More information

Power capacitors in general

Power capacitors in general INDEX Power capacitors in general..low VOLTGE CPCITORS MKP (Box )..PPM / MKP TECHNOLOGY..OPERTING CONDITION.. Voltage..mbient temperature.. Installation.. Discharge the capacitor.. Inrush current limitation..

More information

Three Core XLPE/LSF/SWA/LSF Power Cable

Three Core XLPE/LSF/SWA/LSF Power Cable 1 Three Core XLPE/LSF/SWA/LSF Power Cable./ kv Application LSF armoured power cable for use in fixed installations. Especially for use in areas where fire would create dense smoke and toxic fumes causing

More information

Trade of Electrician. Resistance Network Measurement

Trade of Electrician. Resistance Network Measurement Trade of Electrician Standards Based Apprenticeship Resistance Network Measurement Phase 2 Module No. 2.1 Unit No. 2.1.5 COURSE NOTES Created by Gerry Ryan - Galway TC Revision 1. April 2000 by Gerry Ryan

More information

Electric Field Mapping

Electric Field Mapping PC1143 Physics III Electric Field Mapping 1 Objectives Map the electric fields and potentials resulting from three different configurations of charged electrodes rectangular, concentric, and circular.

More information

1..LOW VOLTAGE POWER CAPACITORS MKP (CYLINDRICAL) 2 2..PPM / MKP TECHNOLOGY 2 3..OPERATING CONDITION Voltage Ambient temperature

1..LOW VOLTAGE POWER CAPACITORS MKP (CYLINDRICAL) 2 2..PPM / MKP TECHNOLOGY 2 3..OPERATING CONDITION Voltage Ambient temperature INDEX..LOW VOLTGE CPCITORS MKP (CYLINDRICL)..PPM / MKP TECHNOLOGY..OPERTING CONDITION.. Voltage..mbient temperature.. Installation.. Discharge the capacitor.. Inrush current limitation.. Harmonics.7.Overpresure

More information

BETA Protecting Miniature Circuit Breakers

BETA Protecting Miniature Circuit Breakers Siemens AG 00 / Product overview / High-capacity range 000 A 0000 A 0000 A, high current 0000 A, universal current 000 A ka /0 Comfort range with plug-in terminal / Compact range +N in MW / Additional

More information

UL 1077 DIN Rail Supplementary Protectors

UL 1077 DIN Rail Supplementary Protectors UL 0 DIN Rail Supplementary Protectors Product Overview UL 0 DIN Rail Supplementary Protectors PRODUCT OVERVIEW Product Overview Standard Features WMZS breaker terminals provide finger and back-of-hand

More information

APPROVAL SHEET FOR AL. ELECTROLYTIC CAPACITORS

APPROVAL SHEET FOR AL. ELECTROLYTIC CAPACITORS NO : ED-A5540 TO : APPROVED APPROVAL SHEET FOR AL. ELECTROLYTIC CAPACITORS : BY: Series Description Part No. HV series, PLEASE RETURN US ONE COPY YOUR SIGED SPECIFICATION AFTER YOU APPROVED OF IT. APPROVED

More information

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011 SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with

More information

SPECIFICATION APPLICATION FOR APPROVAL OF

SPECIFICATION APPLICATION FOR APPROVAL OF NO : 080- APPLICATION FOR APPROVAL OF ITEM DESCRIPTION CODE NO MODEL NO : : : : RADIAL INDUCTOR DR 0 X mm DRB) uh(0k),bulk This space is used for customer's approval DATE : 0.08.0. DRAWN BY E. Y. LEE CHECKED

More information

MCB NB1-63H Miniature Circuit Breaker

MCB NB1-63H Miniature Circuit Breaker NB-H Miniature Circuit Breaker. General. Function protection of circuits against short-circuit currents, protection of circuits against overload currents, switch, isolation, NB-H circuit-breakers are used

More information

MX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E

MX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E OMPT ND USER FRIENDLY MX Series Metal Tube Type Variable rea Flowmeter OUTLINE MX Series flowmeter is the metal tube type variable area flowmeter having the unified face-to-face dimension. The compact

More information

Zelio Relay - Solid State Relays

Zelio Relay - Solid State Relays Selection guide SSR solid state relays Applications Panel mounted PF00--Q Contact type N/O SPST contact Control voltage ranges a 0 0 V c V Operating voltages a 0 V, 0 V, 0 V Type of switching a Zero voltage

More information

EDSA IEC 909 SHORT CIRCUIT ANALYSIS

EDSA IEC 909 SHORT CIRCUIT ANALYSIS 1.0 Tutorial Exercise This tutorial exercise will serve as a validation and verification test for the EDSA IEC 909 short circuit program. The tutorial will be based on two examples documented in the IEC

More information

THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE

THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN PANEL BOARDS ADDRESSED TO HAZARDOUS AREAS - PART THREE July 04 THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE In this third part. we want to speak about how important is the correct sizing of the

More information

Multi-function, economical instrument with 4 functions in the same casing. Accessibility and safety: large-dimension terminals Insulated circuits

Multi-function, economical instrument with 4 functions in the same casing. Accessibility and safety: large-dimension terminals Insulated circuits 200 > Measurement and instrumentation Programmable digital transducers TRIAD 2 range Programmable digital transducers with to 4 analogue outputs Programmable accuracy class PRODUCT ADVANTAGES Up to 4 PROGRAMMABLE

More information

FMS series Metal Strip Shunt Lead Free Current Sensing Resistors

FMS series Metal Strip Shunt Lead Free Current Sensing Resistors 1. Features......2 2. Applications...... 2 3. Dimension and construction.. 2 4. Power Derating Curve....3 5. Rating.3 6. Part Number.. 3 7. Marking / Soldering..4 8. Reliability Performance..5 9. Packing.

More information

Unit 2. ET Unit 2. Voltage, Current, and Resistance. Electronics Fundamentals Circuits, Devices and Applications - Floyd. Copyright 2009 Pearson

Unit 2. ET Unit 2. Voltage, Current, and Resistance. Electronics Fundamentals Circuits, Devices and Applications - Floyd. Copyright 2009 Pearson ET 115 - Unit 2 Voltage, Current, and Resistance The Bohr atom The Bohr atom is useful for visualizing atomic structure. The nucleus is positively charged and has the protons and neutrons. Electrons are

More information

EXEMPLAR NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL PRINCIPLES AND PRACTICE NQF LEVEL 3 ( ) (X-Paper) 09:00 12:00

EXEMPLAR NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL PRINCIPLES AND PRACTICE NQF LEVEL 3 ( ) (X-Paper) 09:00 12:00 NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL PRINCIPLES AND PRACTICE NQF LEVEL 3 2008 (12041002) (X-Paper) 09:00 12:00 EXEMPLAR This question paper consists of 7 pages. EXEMPLAR -2- NC(V) TIME: 3 HOURS

More information

Chapter 2. Chapter 2

Chapter 2. Chapter 2 Chapter 2 The Bohr atom The Bohr atom is useful for visualizing atomic structure. The nucleus is positively charged and has the protons and neutrons. Electrons are negatively charged and in discrete shells.

More information

Potentiometer e.t.c. 1/240 with attach to our switching device 2011

Potentiometer e.t.c. 1/240 with attach to our switching device 2011 Potentiometer e.t.c. /20 { = 0. kohm, with centre tap 2 x 0. kohm 2 =.0 kohm, with centre tap 2 x.0 kohm = resistance value linear and part number ^= = 2.0 kohm, with centre tap 2 x 2.0 kohm =.0 kohm,

More information

Issued August DATA SHEET. 3VT3 MCCB up to 630 A

Issued August DATA SHEET. 3VT3 MCCB up to 630 A ssued August 9 DATA SHEET VT MCCB up to 6 A Based on Siemens Catalog V 6 8 Circuit breakers Switch disconnectors Technical specifications Specifications Type VT 76-AA6/6/56-AA, VT 76-AA6/6/56-AA Circuit

More information

Engineering Fundamentals and Problem Solving, 6e

Engineering Fundamentals and Problem Solving, 6e Engineering Fundamentals and Problem Solving, 6e Chapter 17 Electrical Circuits Chapter Objectives Compute the equivalent resistance of resistors in series and in parallel Apply Ohm s law to a resistive

More information

EPR Insulated, Heavy Duty HOFR Sheathed Flexible Cables

EPR Insulated, Heavy Duty HOFR Sheathed Flexible Cables 1 EPR Insulated, Heavy Duty HOFR Sheathed Flexible Cables 0 C 0/0 V *TQ Application For power/lighting services and mains supply or extension leads in situations requiring frequent handling, trailing and

More information

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS. Type PVA10 / PV10 PV14 PV22 Rated current I n up to 32 A up to 63 A up to 125 A Rated voltage U n

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS. Type PVA10 / PV10 PV14 PV22 Rated current I n up to 32 A up to 63 A up to 125 A Rated voltage U n Varius SUMMARY OF MODELS OF HRC FUSE-LINKS Type A / Rated current I n up to A up to up to A Rated voltage U n AC V, V V, V, 9 V V, V, 9 V DC V V V Fuse-link size x8 x x8 Utilization category of the fuse-link

More information

3. The figure above shows two pith balls suspended by threads from a support. In the figure,

3. The figure above shows two pith balls suspended by threads from a support. In the figure, 3. The figure above shows two pith balls suspended by threads from a support. In the figure, Student ID: 22133336 Exam: 002901RR - Electronics Basics When you have completed your exam and reviewed your

More information

FrelTec GmbH. Metal Film Resistor

FrelTec GmbH. Metal Film Resistor GmbH Mathildenstr. 10A 82319 Starnberg Germany Metal Film Resistor 10/5/2010 1/21 Freltec GmbH www.freltec.com SPECIFICATION Part Number 052 012 * N * J * TB * E * 1 * _ * _ * Type 052 : Metal Film Resistor

More information

Fault Calculation Methods

Fault Calculation Methods ELEC9713 Industrial and Commercial Power Systems Fault Calculation Methods There are two major problems that can occur in electrical systems: these are open circuits and short circuits. Of the two, the

More information

Feasibility of HTS DC Cables on Board a Ship

Feasibility of HTS DC Cables on Board a Ship Feasibility of HTS DC Cables on Board a Ship K. Allweins, E. Marzahn Nexans Deutschland GmbH 10 th EPRI Superconductivity Conference Feasibility of HTS DC Cables on Board a Ship 1. Can superconducting

More information

Some Important Electrical Units

Some Important Electrical Units Some Important Electrical Units Quantity Unit Symbol Current Charge Voltage Resistance Power Ampere Coulomb Volt Ohm Watt A C V W W These derived units are based on fundamental units from the meterkilogram-second

More information

Fire Resistant Armoured Power Cable

Fire Resistant Armoured Power Cable Power and Wiring Cables Fire Resistant Armoured Power Cable 00/00V Application Armoured fire resistant cable for use in fixed wiring installations where it is necessary for the cable to retain circuit

More information

SPECIFICATION CUSTOMER : SHEET NO. DATE MODEL NAME DR2-102K-B & T DR 6.5X7.5mm PART NAME. Radial Inductor PART NO.

SPECIFICATION CUSTOMER : SHEET NO. DATE MODEL NAME DR2-102K-B & T DR 6.5X7.5mm PART NAME. Radial Inductor PART NO. PART NAME Radial Inductor PART NO. DR)mH(0K) SHEET NO. DATE MODEL NAME DESCRIPTION OF 0 06-09-0 DR-0K-B & T DR 6.5X7.5mm. GENERAL ) SCOPE This specfication applies to part number mh PEAKING COIL for use

More information

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8. TF / TF -Ex Field mounted temperature transmitters, PROFIBUS PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN P R O F I PROCESS FIELD BUS B U S Input Resistance thermometer (,, -wire

More information

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure .13 Ex-Floodlights of the series / (Zone 2, 22) The powerful LED floodlights FMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all general lighting applications in

More information

3VT4 Molded Case Circuit Breakers up to 1000 A

3VT4 Molded Case Circuit Breakers up to 1000 A VT4 Molded Case Circuit Breakers up to 00 A Catalog Technical nformation VT4 Molded Case Circuit Breakers up to 00 A General data / - Overview Circuit breakers Switch disconnectors / - Selection and ordering

More information

TeSys circuit-breakers

TeSys circuit-breakers Presentation Thermal-magnetic motor circuit-breakers types GV2, GV and GV7 GV2-ME, GV2-P, GV-ME and GV7-R motor circuit-breakers are -pole thermal-magnetic circuit-breakers specifically designed for the

More information

Notes on Electricity (Circuits)

Notes on Electricity (Circuits) A circuit is defined to be a collection of energy-givers (batteries) and energy-takers (resistors, light bulbs, radios, etc.) that form a closed path (or complete path) through which electrical current

More information

Digital display Pressure range ON/OFF output Linear output Model No Positive pressure 0 to 98 kpa (0 to 1 kgf/cm 2 ) NPN open collector o 1 to o5

Digital display Pressure range ON/OFF output Linear output Model No Positive pressure 0 to 98 kpa (0 to 1 kgf/cm 2 ) NPN open collector o 1 to o5 Pressure Sensor E8CC with Built-in Microcomputer and Digital Display and New E8CB General-purpose Model Withstands a of 490 kpa (5 kgf/cm 2 ) and highly reliable. Incorporates a two-turn adjuster ensuring

More information

Chapter 18. Direct Current Circuits

Chapter 18. Direct Current Circuits Chapter 18 Direct Current Circuits Sources of emf The source that maintains the current in a closed circuit is called a source of emf Any devices that increase the potential energy of charges circulating

More information

Current Sensing Resistors FBF Series Metal Paste Type High Power Lead Free Chip Resistors

Current Sensing Resistors FBF Series Metal Paste Type High Power Lead Free Chip Resistors 1. SCOPE 1.1 Purpose Current Sensing Resistors Fixed Thick-Film Metal Paste High-Power Chip Resistors. Rated power up to 2W and apply to Current Sensing in : Consumer Electronics SMPS M/B BTC Portable

More information

MKP.g. 1.0 Rated Values and Operational Data

MKP.g. 1.0 Rated Values and Operational Data Applications DC and AC voltages Professional Applications Tuned circuits, filters, timers Integrators, S/H Coupling / decoupling, audio Instrumentation Main Characteristics Dry film-foil based technology

More information

Power and Energy Measurement

Power and Energy Measurement Power and Energy Measurement EIE 240 Electrical and Electronic Measurement April 24, 2015 1 Work, Energy and Power Work is an activity of force and movement in the direction of force (Joules) Energy is

More information

5SJ4...-.HG Circuit Breakers to IEC and UL 489

5SJ4...-.HG Circuit Breakers to IEC and UL 489 Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T... Magnetic and Hydraulic-Magnetic Circuit Breaker 830-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of

More information

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components: SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine

More information

Chapter 1: Quantities and Units

Chapter 1: Quantities and Units Chapter 1: Quantities and Units Instructor: Jean-François MILLITHALER http://faculty.uml.edu/jeanfrancois_millithaler/funelec/spring2017 Slide 1 Power of Ten Base Exponent 10 x 10 4 = 1 x 10 4 = 10000

More information

CTC 155 / 350 / 660 Dry-block calibrator

CTC 155 / 350 / 660 Dry-block calibrator CTC 155 / 350 / 660 Dry-block calibrator Wide temperature range: CTC-155: -25 to 155 C CTC-350: 28 to 350 C CTC-660: 28 to 660 C Fast calibration External reference sensor External sensor control Easy

More information

ECE 476 Power System Analysis Fall 2014 Exam #1, Thursday, October 2, :30AM - 10:50AM

ECE 476 Power System Analysis Fall 2014 Exam #1, Thursday, October 2, :30AM - 10:50AM ECE 476 Power System Analysis Fall 4 Exam #, Thursday, October, 4. 9:3AM - :5AM Name: Problem (5 p) Two balanced 3-phase loads are connected in parallel. One is Y-connected and draws 75 kw (3-phase) at.8

More information

Applied Natural Sciences

Applied Natural Sciences Het basisvak Toegepaste Natuurwetenschappen http://www.phys.tue.nl/nfcmr/natuur/collegenatuur.html Applied Natural Sciences Leo Pel e mail: 3nab0@tue.nl http://tiny.cc/3nab0 Bijles Email: p.j.neuraij@tue.nl

More information

To order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle

To order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle otor protection relays - T - FWIT Since % of -phase motor failures are due to load problems or loss of phase, the CROUZET range of motor protection relays is indispensable! models give motor protection

More information