Three Core XLPE/LSF/SWA/LSF Power Cable
|
|
- Mervyn Hood
- 5 years ago
- Views:
Transcription
1 1 Three Core XLPE/LSF/SWA/LSF Power Cable./ kv Application LSF armoured power cable for use in fixed installations. Especially for use in areas where fire would create dense smoke and toxic fumes causing a major threat to life and equipment. Specifications In accordance with BS. s: Stranded Class copper conductors to BS EN 0. Extruded semi-conducting layer. Insulation: XLPE insulation. Extruded semi-conducting layer. Plain copper tape screen. Inner Sheath: LSF inner sheath Type LTS1 to BS. Mild galvanised steel wires to BSEN-1. Outer Sheath: Red LSF outer sheath Type LTS1 to BS. Flame retardant to BS EN 0-- & IEC0-- Cat. C as a minimum. Temperature Rating: 0 C maximum conductor operating temperature. Voltage Rating: 0/000V. For further technical information refer to page 1:
2 Anixter Number AEN- Number of Cores Three Core XLPE/LSF/SWA/LSF Power Cable./kV Insulation Thickness Diameter Under Armour Armour Wire Size O/D Approx Weight kg/km Minimum Bending Radius During Installation Adjacent to joints and Termination
3 1 Technical Information 1 and core XLPE Insulated Cables 00/00V, 0/000V & 00/000V For further guidance refer to the BS1 (IEE Wiring Regulations - latest edition). NB. High voltage cables are not specifically covered in IEE Wiring Regulations but reference should be made to ensure compliance. For ambient air and ground temperatures other than those specified, the following factors should be applied. Cables laid in air Ambient air temp C Rating factor Cables laid direct in ground and in single-way ducts Ground temp C Rating factor Standard depth of laying 0.m Thermal resistivity of soil 1. C m/w Standard ground temperature C Ambient air temperature C Maximum conductor temperature 0 C NOTE: All circuits thermally independent Cables in trefoil group are solidly bonded Cables in flat formation are single point bonded 01 0
4 CURRENT CARRYING CAPACITY (Amperes) Single Core./. kv,./ kv,./ kv 0 Hz Direct Burial Duct Air Cables Trefoil Flat Spaced Technical Information Cables Cables Trefoil Flat Touching Trefoil Flat Spaced Arm d Arm d Unarm d Arm d Unarm d Arm d Unarm d Arm d Unarm d Arm d Core./. kv,./ kv,./ kv 0 Hz XLPE/PVC/SWA/PVC & XLPE/LSF/SWA/LSF Direct Burial In Single-Way Duct Air Core Core Core Arm d Arm d Arm d
5 Single core PCU/XLPE/PVC 0/000V to BS Single core PCU/XLPE/AWA/PVC 0/000V to BS ELECTRICAL CHARACTERISTICS Size Maximum d.c. 0ºC Three core PCU/XLPE/PVC 0/000V to BS Three core PCU/XLPE/PVC/SWA/PVC 0/000V to BS ELECTRICAL CHARACTERISTICS Maximum a.c. 0ºC Also applicable to LSF sheathed versions to BS 0Hz Technical Information 0ºC, 0Hz Single Core Cables in Trefoil Single Core Cables in Trefoil Unarm d Arm d Unarm d Arm d Unarm d Arm d Size Maximum d.c. 0ºC Maximum a.c. 0ºC 0Hz 0ºC, 0Hz
6 1 Additional Technical Information Short-Circuit Ratings XLPE Insulated Cables Short-Circuit Ratings Size 0.s duration ka 1.0s duration ka s duration ka N.B: The above ratings assume an adiabatic temperature rise and are based on a conductor temperature of 0ºC at start of short-circuit and 0ºC at end of shortcircuit.
Single Core XLPE/LSF/AWA/LSF Power Cable
Single Core XLPE/LSF/AWA/LSF Power Cable 00/00V and 100/00V Application LSF insulated, armoured and sheathed, single core power cable for use in fixed installations. Especially for use in areas where fire
More informationFire Resistant Armoured Power Cable
Power and Wiring Cables Fire Resistant Armoured Power Cable 00/00V Application Armoured fire resistant cable for use in fixed wiring installations where it is necessary for the cable to retain circuit
More informationEPR Insulated, Heavy Duty HOFR Sheathed Flexible Cables
1 EPR Insulated, Heavy Duty HOFR Sheathed Flexible Cables 0 C 0/0 V *TQ Application For power/lighting services and mains supply or extension leads in situations requiring frequent handling, trailing and
More informationControlflex CY-LSF Type
Low Smoke Zero Halogen Screened Flexible Cable 00/00V 0 C Application These flexible cables are designed for industrial control and instrumentation circuits and interconnections between mobile and fixed
More informationH07RN-F. Flexible Cables and Cords 60 C 450/750 V. Application. Specifications
H0RN-F 0 C 0/0 V Application For mains supply or extension leads for portable or fixed equipment operating indoors or outdoors (domestic or industrial) under conditions of frequent handling trailing or
More information25 (μh/ω) for sizes 0,5 / 0,75 / 1 mm2 Maximum L/R Ratio:
Based on: EN 50288-7 Nominal voltage: 500V The colours may differ from the actual colours. 1. Construction: 1. : Stranded annealed bare copper. Class 2 in accordance with IEC 60228. 2. : Fire barrier:
More informationNYY-J/-o 34 NYCWY 36 NYCY 37 NAYY 38
NYY-J/-o 34 NYCWY 36 NYCY 37 NAYY 38 NYY-J/-O Energy and control cable acc. to DIN VDE 0276 and HD 603 Application Indoor and outdoor installation, laying in ducts and underground, for power stations,
More informationElectrical Power Cables Part 2 Cable Rating Calculations
ELEC971 High Voltage Systems Electrical Power Cables Part Cable Rating Calculations The calculation of cable ratings is a very complex determination because of the large number of interacting characteristics
More informationSHIPS & OFFSHORE CABLES BS 6883 BS 7917
ControlCavi Industria SHIPS & OFFSHORE CABLES BS 6883 BS 7917 with FIREBAR the TOTAL SAFETY fire and water resistant cable System certifications CCI Quality CCI Evironmental CCI Evironmental CCI Health
More information16 Appendix 16 Electrical Research Association Report
Guide to the Wiring Regulations 16 Appendix 16 Electrical Research Association Report (ERA) report on armoured cables with external CPCs The attached report was commissioned by the ECA and is copyright
More informationControlCavi Industria FPSO CABLES. with FIREBAR the TOTAL SAFETY fire and water resistant cable
ControlCavi Industria FPSO CABLES with FIREBAR the TOTAL SAFETY fire and water resistant cable System certifications CCI Quality CCI Evironmental CCI Evironmental CCI Health & Safety CABLE SERVICE Quality
More informationDEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK SUBJECT CODE & NAME: EE 2303 - TRANSMISSION & DISTRIBUTION YEAR / SEM: III/V UNIT-I TRANSMISSION SYSTEM INTRODUCTION PART-A 1. What is
More informationTHE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE
July 04 THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE In this third part. we want to speak about how important is the correct sizing of the
More informationOverhead lines. 110 kv wood tower with guy wires
Overhead lines a) ja b) 0 kv wood poles c) free standing 0 kv metal tower with I-strings d) free standing 440 kv metal tower with V-strings e) 400 kv metal tower with guy wires 0 kv wood tower with guy
More informationParametric Study of Losses in Cross-Bonded Cables: Conductors Transposed Versus Conductors Nontransposed
IEEE TRANSACTIONS ON POWER DELIVERY, VOL 28, NO 4, OCTOBER 2013 2273 Parametric Study of Losses in Cross-Bonded Cables: Conductors Transposed Versus Conductors Nontransposed Prajakta Moghe and Francisco
More informationComparison of Finite Element Analysis to IEC for Predicting Underground Cable Ampacity
Comparison of Finite Element Analysis to IEC-60287 for Predicting Underground Cable Ampacity Simon Dubitsky Tor Ltd, St. Petersburg, Russia simon.dubitsky@ieee.org Georgy Greshnyakov Sevkabel Research
More informationDeliverable Report. Offshore House, Albert Street, Blyth, Northumberland, NE24 1LZ
Deliverable Report Report issued to: ORE Catapult Project: ORE1601 Offshore House, Albert Street, Blyth, Northumberland, NE24 1LZ Project Engineer: Hytham Emam Deliverable Number: 1 Email: hytham.emam@ore.catapult.org.uk
More informationELECTRICAL AND THERMAL DESIGN OF UMBILICAL CABLE
ELECTRICAL AND THERMAL DESIGN OF UMBILICAL CABLE Derek SHACKLETON, Oceaneering Multiflex UK, (Scotland), DShackleton@oceaneering.com Luciana ABIB, Marine Production Systems do Brasil, (Brazil), LAbib@oceaneering.com
More informationM I N I S T R Y O F C O M M U N I C A T I O N S T E L E C O M M U N I C A T I O N S S E C T O R T E C H N I C A L S T A N D A R D F O R
M I N I S T R Y O F C O M M U N I C A T I O N S T E L E C O M M U N I C A T I O N S S E C T O R T E C H N I C A L S T A N D A R D F O R M A T E R I A L S N O. G 2 0 : 1 0 : 0 0 1 : 1 8 J U M P E R W I
More informationCollation Studies of Sequence Impedances for Underground Cables with Different Layouts
Collation Studies of Sequence Impedances for Underground Cables with Different Layouts M.Ramya 1, G.Radhika 2, Poonam Upadhyay 3 1 Department of EEE, VNRVJIET, Hyderabad, India 2 Department of EEE, Sr.Assistant
More informationThermal-Magnetic Circuit Breaker 2210-T2...
Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring
More informationMR medium rating busbar
technical information General features MR is fully compliant with S EN 0-, specifically, the rated current of the Zucchini busbar trunking systems is always rated at the average ambient temperature of
More informationThe influence of thermal properties on power transmission characteristics of HVDC cables a factor analysis
The influence of thermal properties on power transmission characteristics of HVDC cables a factor analysis Björn Sonerud, Wendy Loyens Borealis B bstract Power transmission capacity of HVDC cable links
More informationVarius SUMMARY OF MODELS OF HRC FUSE-LINKS
SUMMARY OF MODELS OF HRC FUSE-LINKS Type PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size
More informationSHIPLINK. LSHF CABLE NEK TS 606 : 2016 Cable solutions and services for safety and reliability in ship and offshore
SHIPLINK LSHF CABLE NEK TS 0 : 0 Cable solutions and services for safety and reliability in ship and offshore Contents General Introduction Cable Construction Detail Cable designation Reference standard
More informationPolitecnico di Torino THERMAL ANALYSIS OF POWER LINES: METHODOLOGIES AND APPLICATIONS
Politecnico di Torino Dottorato in Ingegneria Elettrica Scienze elettriche THERMAL ANALYSIS OF POWER LINES: METHODOLOGIES AND APPLICATIONS Tesi di Dottorato Supervisors: Prof. Aldo CANOVA Ing. Fabio FRESCHI
More informationTHERMAL ANALYSIS OF UMBILICAL CABLES
Proceedings of COBEM 2007 Copyright 2007 by ABCM 19th International Congress of Mechanical Engineering November 5-9, 2007, Brasília, DF THERMAL ANALYSIS OF UMBILICAL CABLES Rosianita Balena, rbalena@oceaneering.com
More informationQualification Test Report. Modular Plugs, Unshielded and Shielded
Qualification Test Report 501-131013 26 JAN 16 Rev. A Modular Plugs, Unshielded and Shielded 1. INTRODUCTION 1.1. Purpose Testing was performed on modular plugs to determine their conformance to the requirements
More informationVarious Busduct Assemblies: Various Busduct Assemblies: Various Busduct Assemblies:
Cast Resin Product Product Specification Specification Product Feature Specification Feature Featur Compliance IEC 69- Compliance IEC 69- IEC 609- for Compliance IEC 609- LV and IEC for IEC 69- LV 6- IEC
More informationVKES. Contents. Page 2 No 213, 13th Main RBI Layout JP Nagar 7th Phase, Bangalore Vidyuth Kanti Engineering Services
Contents What is earthing... 4 Why do we do earthing... 4 What is the Scope of this guideline... 4 How to protect a person in a substation against electrical shock... 4 What happens during a fault... 4
More informationIndependent, accredited testing station Member laboratory of STL and LOVAG TEST CONFIRMATION. on the given range of performed tests
Independent, accredited testing station Member laboratory of STL and LOVAG TEST CONFIRMATION on the given range of performed tests 3M Laboratories Europe Zweigniederlassung der 3M Deutschland GmbH Carl-Schurz-Str.
More informationELECO'2001. Paper Submission Form
ELECO'2001 Paper Submission Form Name of Presenting Author... Cuneyt OYSU Address... Kocaeli Üniversitesi Mekatronik Mühendisliği Bölümü Veziroğlu Kampüsü 41040 İzmit/Kocaeli Phone (262) 5282467 (532)
More informationC60N circuit breakers0 B, C and D curves IEC 60898: 6000 A, IEC : 10 ka
C0N circuit breakers0 B, C and s IEC 0898: 000 A, IEC 097-: 0 ka Function b The circuit-breakers combine the following functions: v protection of circuits against short-circuit currents v protection of
More informationWhat is a short circuit?
What is a short circuit? A short circuit is an electrical circuit that allows a current to travel along an unintended path, often where essentially no (or a very low) electrical impedance is encountered.
More information5SJ4...-.HG Circuit Breakers to IEC and UL 489
Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is
More informationEngineering Recommendation EREC S34 Issue 2, November A guide for assessing the rise of earth potential at electrical installations
PRODUCED BY THE OPERATIONS DIRECTORATE OF ENERGY NETWORKS ASSOCIATION Engineering Recommendation EREC S34 Issue 2, November 2018 A guide for assessing the rise of earth potential at electrical installations
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...
Magnetic and Hydraulic-Magnetic Circuit Breaker 830-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of
More informationF th International Conference on Insulated Power Cables F2.23
Estimating the losses in three-core submarine power cables using 2D and 3D FEA simulations Sebastian STURM, Johannes PAULUS; University of applied Sciences Würzburg-Schweinfurt, Germany, Sebastian.Sturm@fhws.de,
More informationCLASSix UTP Patch Cords
Features Patch Cords are used in the work area and cross-connect generic cabling applications Comprise a length of eight-wire flexible patch cable, terminated with snagless high quality, two eight-position
More informationTRANSMISSION LINES. All aluminum alloy conductor (AAAC) Aluminum conductor alloy reinforced (ACAR)
TRANSMISSION LINES. Transmission Structures An overhead transmission line consists of conductor, insulators, support structures and in most cases shield wires. Overhead power transmission lines are classified
More informationPVC INSULATED, SINGLE CORE FLEXIBLE CABLES H07V-K
E-CTLOG H07V-K PVC INSULTED, SINGLE CORE FLEXIBLE CBLES HO5V-K, HO7V-K CU/PVC TS EN 505-2-31, VDE 0281, IEC 0227, BS 004 CU: IEC 0228 CLSS 5 K: Flexible conductor Rated voltage : 0/750 V Used in control
More informationExperimental Study on the Cyclic Ampacity and Its Factor of 10 kv XLPE Cable
Energy and Power Engineering, 203, 5, 22-225 doi:0.4236/epe.203.54b23 Published Online July 203 (http://www.scirp.org/journal/epe) Experimental Study on the Cyclic Ampacity and Its Factor of 0 kv XLPE
More informationBETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008
LV HRC fuse links Overview LV HRC fuses are used for installation systems in non-residential, commercial and industrial buildings as well as in switchboards of power supply companies. They therefore protect
More informationPressure transmitters for industrial applications MBS 32 and MBS 33
Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer
More informationDATA RACK BUSBAR. Data Rack Busbar Systems A.
Data Rack Busbar Systems 250...1000 A www.eae.com.tr Overview Overview To power the mission critical IT infrastructures on the Data Rack Cabinets, EAE offers a highly flexible and reliable Busbar System
More informationThe development of a Roebel cable based 1 MVA HTS transformer
The development of a Roebel cable based 1 MVA HTS transformer Neil Glasson 11 October 2011 Mike Staines 1, Mohinder Pannu 2, N. J. Long 1, Rod Badcock 1, Nathan Allpress 1, Logan Ward 1 1 Industrial Research
More informationHyperPlus 5e Plenum. Contact Copper LAN Product Inquiry Phone:
Berk-Tek's HYPER PLUS 5e Standard Category 5e UTP Cables are designed for horizontal network and voice applications in a structured cabling network to connect between the user outlet and horizontal cross-connect.
More informationMagnetic field shielding of underground power cables in urban areas: a real-life example
Boundary Elements XXVII 527 Magnetic field shielding of underground power cables in urban areas: a real-life example L. Battistelli, A. Geri & G. M. Veca Department of Electrical Engineering, University
More informationFUNDAMENTALS OF CALCULATION OF EARTH POTENTIAL RISE IN THE UNDERGROUND POWER DISTRIBUTION CABLE NETWORK
Companion Document to NCCPTS Application Guide for Cable Sheath Bonding FUNDAMENTALS OF CALCULATION OF EARTH POTENTIAL RISE IN THE UNDERGROUND POWER DISTRIBUTION CABLE NETWORK Ashok Parsotam March 997
More informationLatest Status of High Temperature Superconducting Cable Projects
Latest Status of High Temperature Superconducting Cable Projects Y.Ashibe, H.Yumura, M.Watanabe, H.Takigawa, H.Ito, M.Ohya, T.Masuda and M.Hirose Sumitomo Electric Industries, Ltd.Osaka,554-0024 Japan
More information7S SERIES. Relay module with forcibly guided contacts 6 A 7S S /0310 7S
Relay module with forcibly guided contacts.12 with 2 pole (1NO + 1 N).14 with 4 pole (2 NO + 2 N and 3 NO + 1 N).16 with 6 pole (4 NO + 2 N) For safety applications, with class A forcibly guided contact
More informationIndependent, accredited testing station Member laboratory of STL and LOVAG TEST CONFIRMATION. on the given range of performed tests
Independent, accredited testing station Member laboratory of STL and LOVAG TEST CONFIRMATION on the given range of performed tests 3M Laboratories Europe Zweigniederlassung der 3M Deutschland GmbH Carl-Schurz-Str.
More informationVarius SUMMARY OF MODELS OF HRC FUSE-LINKS. Type PVA10 / PV10 PV14 PV22 Rated current I n up to 32 A up to 63 A up to 125 A Rated voltage U n
Varius SUMMARY OF MODELS OF HRC FUSE-LINKS Type A / Rated current I n up to A up to up to A Rated voltage U n AC V, V V, V, 9 V V, V, 9 V DC V V V Fuse-link size x8 x x8 Utilization category of the fuse-link
More information5SP and 5SY Supplementary Protection UL 1077
Product Guide 5SP and 5SY Supplementary Protection UL 077 for North merican and International applications usa.siemens.com/5sy Table of contents Certifications, standards, features and description Characteristic
More informationSuperconducting cables Development status at Ultera
1 Superconducting cables Development status at Ultera "Superconductors and their Industrial Applications Pori, 15-16 Nov 2006 Chresten Træholt (D. Willén) Senior Development Engineer, Ultera A Southwire
More informationWorked Example for the Calculation of Earthing Current and Electric Shock Hazard Potential Difference in a Rod and Grid Earthing System
Appendix H Worked Example for the Calculation of Earthing Current and Electric Shock Hazard Potential Difference in a Rod and Grid Earthing System H.1 WORKED EXAMPLE A 33 kv overhead line terminates at
More informationAccelerators. Table Quadrupole magnet
Accelerators 2.6 Magnet System 2.6.1 Introduction According to the BEPCII double ring design scheme, a new storage ring will be added in the existing BEPC tunnel. The tasks of the magnet system can be
More informationMineral-insulated thermocouples to DIN and EN
Data Sheet 90.1210 (90.1221) Page 1/7 s to DIN 43 710 and EN 60 584 for temperatures from -200 to +1200 C flexible sheath with shock-proof measuring insert protection tube diameter from 0.5mm fast response
More informationF F FAULT CURRENT Prospective. 1. Introduction. 2. Types of fault conditions
FAULT CURRENT F F13-13 FAULT CURRENT - Contents 1. Introduction 2. Types of fault conditions 3 fault current must be determined 3.1 Purposes for which of prospective fault current magnitudes are used 3.2
More informationECE 325 Electric Energy System Components 5 Transmission Lines. Instructor: Kai Sun Fall 2015
ECE 325 Electric Energy System Components 5 Transmission Lines Instructor: Kai Sun Fall 2015 1 Content (Materials are from Chapter 25) Overview of power lines Equivalent circuit of a line Voltage regulation
More informationInterference suppression film capacitors MKP 336 1
MKP RADIAL POTTED TYPE PITCH /15/22.5/27.5 mm l b h lt P d t CBA196 Fig.1 Simplified outlines. FEATURES to 27.5 mm lead pitch Supplied loose in box and taped on reel Consists of a low-inductive wound cell
More informationModule 3 : Sequence Components and Fault Analysis
Module 3 : Sequence Components and Fault Analysis Lecture 13 : Sequence Modeling (Tutorial) Objectives In this lecture we will solve tutorial problems on fault analysis in sequence domain Per unit values
More informationNR/RR. Set No. 2 CODE NO: NR/RR210204
Set No. 2 II B.Tech I Semester Examinations,May 2011 ELECTROMAGNETIC FIELDS Electrical And Electronics Engineering Time: 3 hours Max Marks: 80 Answer any FIVE Questions All Questions carry equal marks
More informationFeasibility of HTS DC Cables on Board a Ship
Feasibility of HTS DC Cables on Board a Ship K. Allweins, E. Marzahn Nexans Deutschland GmbH 10 th EPRI Superconductivity Conference Feasibility of HTS DC Cables on Board a Ship 1. Can superconducting
More information1. Introduction. 2. Use of COMSOL Multiphysics
Excerpt from the Proceedings of the COMSOL Conference 2009 Milan Failure Modes of Underground MV Cables: Electrical and Thermal Modelling. Peter A Wallace *, Mohamed Alsharif, Donald M Hepburn and Chengke
More informationNon-Contact Safety Systems CMS
Selection table for non-contact safety system // Evaluation units Connection Desi Read head contact assembly Assured switch-on distance S ao [mm] Assured switch-on distance S ar [mm] Number of outputs
More informationTable of Contents Pin-Configuration Selection Guide for HDE, HDS, & EFP
Table of Contents -Configuration Selection Guide for HDE, HDS, & EFP Service Voltage Rating... Electrical Service Ratings... Ampacity Ratings by Contact... Electrical Service Ratings Explained... Operating
More informationR&D of 22.9kV/50MVA HTS Transmission Power Cable in Korea
Symposium on HTS Cable Application in Kunming R&D of 22.9kV/50MVA HTS Transmission Power Cable in Korea Jeonwook Cho Korea Electrotechnology Research Institute jwcho@keri.re.kr June 24, 2004 Order Introduce
More informationFilm Capacitors. EMI suppression capacitors. Date: June 2018
Film Capacitors EMI suppression capacitors Date: June 2018 EPCOS AG 2018. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without
More informationElectroscope Used to are transferred to the and Foil becomes and
Electricity Notes Chapter 17 Section 1: Electric Charge and Forces Electric charge is a variety of independent all with one single name. Electricity is related to, and both (-) and (+) carry a charge.
More informationPressure. 1 Fitting PA R - N R2
INTERNAL STRUCTURE (R 1/4) 4 1 2 3 FEATURES High corrosion resistance and drip-proof construction port attachment made of Proven IP-65 grade gauge body (IP-65 in accordance with IEC) Standard product provides
More informationBasic Electricity. ME 120 Lecture Notes. Portland State University Mechanical and Materials Engineering
Basic Electricity ME 120 Lecture Notes Portland State University Mechanical and Materials Engineering Learning Objectives Successful completion of this module will enable students to Link the basic model
More informationPressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27
Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for
More information16.1 Electrical Current
16.1 Electrical Current Electric Current Electric Current When the ends of an electric conductor are at different electric potentials, charge flows from one end to the other Flow of Charge Charge flows
More informationZUCCHINI MR - MEDIUM RATING BUSBAR
ZUCCHINI MR - MEDIUM RATING BUSBAR Available in sizes from 0 to 000 A, MR (medium rating) busbar is ideal for power distribution in medium to large installations and rising mains in commercial buildings.
More informationCS Series. Capacitance Type. Type. Proximity Sensor. Features
INFORMATI Series Features Capacitance Type - Metal cylinder/resin cylinder/square type - Non-metal objects such as wood, paper, plastic and water can be detected. - The operating distance is adjustable
More information3M Twisted Pair, Flat Cable,.050" 28 AWG Stranded, Halogen Free Polyolefin, 2100/20TP, 30m
3M Worldwide : United States : Electronics Manufacturing Product Catalog for Electronic Specialty Markets 3M Cable & Assemblies Internal Wiring Twisted Pair Flat Cable, Mass Terminatable,.050 in Pitch,
More informationE8EB-N0C2B E8EB-N0B2B
Slim Sensor CSM DS_E 1 Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree
More informationThermal Analysis by Conduction Convection and Radiation in a Power Cable
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-issn: 2278-1676,p-ISSN: 2320-3331, Volume 9, Issue 3 Ver. II (May Jun. 2014), PP 51-56 Thermal Analysis by Conduction Convection and
More informationCommissioning testing of a 1 MVA Superconducting transformer featuring 2G HTS Roebel cable
Commissioning testing of a 1 MVA Superconducting transformer featuring 2G HTS Roebel cable Glasson N, Staines M, Allpress N, Badcock R 10:45 2M-LS-O2 OUTLINE Introduction Electrical Design Specifications
More informationTechnical Challenge of Lightning Protection for Wind Power Generation
Technical Challenge of Lightning Protection for Wind Power Generation 18 th November,2008 Takayuki Nakamoto,Hiroshi Morita Kinden Corporation Contents 1.Situation of wind power generation in the worldwide
More informationCapacitors. Typical electrical characteristics of metallized polyester capacitors KEU. Type KEU Metallized polyester capacitors
Capacitors Type KEU Metallized polyester capacitors As a dielectric high quality polyester film with good electrical properties is used. Electrodes of capacitor are vacuum metallized aluminium. The thickness
More informationPeriodic Inspection and Testing of Electrical Installations Sample Test ( ) Version 1.3 July 2018
Periodic Inspection and Testing of Electrical Installations Sample Test (2391-051) Version 1.3 July 2018 Sample Questions Version and date Change detail Section 1.3 July 2018 Modified questions/answers
More informationSKA COMPACT. ALL IN ONE Linear Axes
SKA COMPACT ALL IN ONE Linear Axes Cutting-edge all in one linear axis based on iron core technology. A range of three sizes with aluminium carrying structure. The power components, moving coil and magnetic
More informationInstallation Contactors ISU-xxx ISM-xxx
Installation Contactors ISU-xxx ISM-xxx Installation contactors are used in building technology switching cabinets of apartment blocks, office buildings, restaurants and hotels, shopping centres and hospitals
More informationLevel Sensor PanCake PR 6251 and Mounting Kit PR 6051
Level Sensor PanCake PR 6251 and Mounting Kit PR 6051 The space-saving solution for simple applications The sensors of the PR 6251 series have been specially designed for simple weighing of silos and horizontal
More informationFEATURES APPLICATIONS DESCRIPTION QUICK REFERENCE DATA. PILKOR components
FEATURES Excellent anti-surge characteristics Stable characteristics to moisture resistance even in high resistance range. Good replacement for ceramic plate resistors. APPLICATIONS Telecommunication Industrial
More informationG R O U N D R E S I S TA N C E T E S T I N G P R I N C I P L E (Fall of Potential 3-Point Measurement)
G R O U N D R E S I S TA N C E T E S T I N G P R I N C I P L E (Fall of Potential 3-Point Measurement) NOTES The potential diference between rods X and Y is measured by a voltmeter, and the current flow
More informationIdeal wires, Ideal device models, Ideal circuits. Ideal models for circuit elements Wires
Ideal wires, Ideal device models, Ideal circuits Ideal models for circuit elements Wires Currents and Voltages Joints Resistors Voltage sources Current sources. EE 42 Lecture 1 1 Cast of Characters Fundamental
More informationCapacitance Cap. Tol. Suffix construction. Rated voltage 450 VDC
Metallized Polypropylene Film Capacitors Type:ECWFD Plastic Film Capacitors Non-inductive construction using metalized Polypropylene film with flame retardant epoxy resin coating. Features Small size Excellent
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer HO-NSM series I PN = 8, 15, 25 A Ref: HO 8-NSM, HO 15-NSM, HO 25-NSM For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the
More informationGESELLSCHAFT FÜR ELEKTRISCHE HOCHLEISTUNGSPRÜFUNGEN Mitglied der Short-Circuit-Testing Liaison (STL) Test Report
Mitglied der Short-Circuit-Testing Liaison (STL) Test Report Report-No.: 9725Fr Copy-No.: 00 Contents: 16Sheets Equipment under Test: Manufacturer: Client: Metal-enclosed, single-pole metal-clad and SF
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer HO-NP/SP33 series I PN = 8, 15, 25 A Ref: HO 8-NP/SP33, HO 15-NP/SP33, HO 25-NP/SP33 For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the
More informationMAY/JUNE 2006 Question & Model Answer IN BASIC ELECTRICITY 194
MAY/JUNE 2006 Question & Model Answer IN BASIC ELECTRICITY 194 Question 1 (a) List three sources of heat in soldering (b) state the functions of flux in soldering (c) briefly describe with aid of diagram
More informationAC Line Rated Ceramic Disc Capacitors Class X1, 760 V AC, Class Y1, 500 V AC
AC Line Rated Ceramic Disc Capacitors Class X1, 760 V AC, Class Y1, 500 V AC FEATURES Complying with IEC 60384-14 4 th edition Can pass 10 kv pulses (10 per polarity) Withstands 85 / 85 / 1000 h test Reduced
More informationUnit 11 Wire Tables and Conductor Sizes
Wire Tables and Conductor Sizes Objectives: Discuss factors that determine conductor ampacity. Discuss resistance of wire. Determine insulation characteristics. Use temperature correction factors. Determine
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available
More informationUPDATE ON ACCELERATED AGEING OF MV XLPE
UPDATE ON ACCELERATED AGEING OF MV XLPE Author: Presenter: A Falconer Pr Eng B Sc MSAIEE, Manager, Technology Development, Aberdare Cables G Whyte Pr Eng B Sc MSAIEE, General Manager, Aberdare Network
More information