CHAPTER 7 FRACTIONAL ORDER SYSTEMS WITH FRACTIONAL ORDER CONTROLLERS
|
|
- Ambrose Chambers
- 5 years ago
- Views:
Transcription
1 9 CHAPTER 7 FRACTIONAL ORDER SYSTEMS WITH FRACTIONAL ORDER CONTROLLERS 7. FRACTIONAL ORDER SYSTEMS Fractional derivatives provide an excellent instrument for the description of memory and hereditary properties of various materials and processes. This is the main advantage of fractional derivatives in comparison with classical integer-order models, in which such effects are in fact neglected. The advantages of fractional derivatives become apparent in modeling mechanical and electrical properties of real materials, as well as in the description of rheological properties of rocks, and in many other fields. The mathematical modeling and simulation of systems and processes, based on the description of their properties in terms of fractional derivatives, naturally leads to differential equations of fractional order and to the necessity to solve such equations. The idea of fractional derivatives and integrals seems to be quite a strange topic, very hard to explain, due to the fact that, unlike commonly used differential operators, it is not related to some important geometrical meaning, such as the trend of functions or their convexity. For this reason, this mathematical tool could be judged far from reality. But many physical phenomena have intrinsic fractional order description and so fractional order calculus is necessary in order to explain them. Fractional order differential equations accumulate the entire information of the function in weighted form.
2 2 The transfer function of a single input, single output (SISO) system, with the output and the input related by a linear, time-invariant differential equation, is the ratio of the Laplace transforms of the output and of the input, when all initial conditions are zero. This definition also stands when the differential equation involves fractional orders. In general the LTI systems can be classified as integer order systems and fractional order systems. Fractional order systems can further be classified as commensurate order or non commensurate order systems. In commensurate order systems the fractional powers are integer multiples of a fractional number. In non commensurate order systems there is no such generalization occurs. function is given by In case of commensurate order systems the continuous transfer G( s) ( m ) b s m b s L b s b 2 m m ( n ) a s n a s L a s a n n (7.) where b, b 2, b m+ are numerator coefficients a, a 2, a n+ are denominator coefficients is a fractional number function is given by In case of non commensurate order systems the continuous transfer G( s) b s m m b s m - m L b s b a s n n a s n - n L a s a (7.2)
3 2 where b m, b m-, b are numerator coefficients a n, a n-, a are denominator coefficients m, m-,... are numerator fractional powers n, n-, are denominator fractional powers. For integer order systems once the maximum order of the system to be identified is chosen, the parameters of the model can be optimized directly. For fractional order systems, the identification requires (a) the choice of the number of fractional operators, (b) the fractional powers of the operator, and (c) the coefficients of the operators. But to identify the form of transfer function itself, with order and coefficient, an approach from experimental data of frequency domain analysis should be the starting point, to identify unknown systems. 7.. Stability analysis of LTI fractional order systems It is known from the theory of stability that an LTI (linear timeinvariant) system is stable if the roots of the characteristic polynomial are negative or have negative real parts if they are complex conjugate. It means that they are located on the left half of the complex plane. In the fractionalorder LTI case, the stability is different from the integer one. Interesting notion is that a stable fractional system may have roots in the right half of complex plane. Figure 7. shows the stable and unstable regions of fractional order systems.
4 22 Figure 7. Stability of LTI FOS with order <q< It has been shown that system is stable if the following condition is satisfied arg(eig(a)) > q (7.3) where < q < and eig(a) represents the eigenvalues of matrix A. Matignon s stability theorem says the fractional transfer function G(s) = Z(s)/P(s) (7.4) is stable if and only if the following condition is satisfied in s-plane: arg(s) > q (7.5) where s = s q. When s = is a single root of P(s), the system cannot be stable. For q =, this is the classical theorem of pole location in the complex plane, no pole is in the closed right half plane of the first Riemann sheet.
5 23 Generally, consider the following commensurate fractional order system in the form: D q = f( ) (7.6) where < q < and R n. The equilibrium points of system are calculated via solving the following equation f( ) = (7.7) The equilibrium points are asymptotically stable if all the eigen values j, (j =,2,...,n) of the Jacobian matrix J = f/ (7.8) evaluated at the equilibrium, satisfy the condition arg(eig(j)) = arg( j ) > q (7.9) where j =,2,...,n. Apart from many advantages fractional order systems also have some disadvantages which are summarized below. Fractional order differential equations accumulate the entire information of the function in weighted form. Fractionally differentiated state variables must be known as long as the system has been operated. This is known as initialization function. For integer order systems, the initialization function is constant and for fractional order systems it is time varying. Integer order system set of state along with system equations is sufficient to predict the response.
6 24 The fractional dynamic variables do not represent the state of the system. Fractional dynamics require history of states or sufficient number of points by short-memory principle, for initialization function computation. The above memory effect requires large memory. The evolving developments to reduce this requirement in form of power series expansion and continued fraction expansion of the generating function in digital domain are an ongoing process. 7.2 MODELING OF FRACTIONAL ORDER SYSTEM Because of the closeness of fractional description to the real system, the same spherical tank liquid level system is modeled as a fractional order system. Two different approaches are tried in this research work. In both the approaches a non commensurate model of fractional order system is selected First Method In this approach the dead time was not considered first. A fitness function is used to model the spherical tank as a non commensurate model of fractional order system. The fitness function is defined as f F = t i C ( t ) - P(t) 2 (7.) m
7 25 Where, k C (s) = (7.) m s is the rationalized integer order transfer function model of spherical tank and l P(s) = (7.2) a 2 a a 2 s s s is the fractional order transfer function model of the same spherical tank. The selected non commensurate fractional order transfer function model (Podlubny 999) is G(s) ans n n a s... a s a s n (7.3) where k is an arbitrary real number, n > n- >. > >, a k is an arbitrary constant, Here n is selected as 2. So the resultant FOTF is G(s) = 2 a s a s a s 2 (7.4) As said previously for modeling the spherical tank as a FOS, first the dead time was not considered; only the remaining first order transfer function of FOPDT was approximated as a fractional order system using
8 26 curve fitting method and then the resultant FOTF was combined with the dead time. An operating point of 2cm was selected. Step input was applied to the FOPDT model and the obtained response was taken as C m (t). Then the step input of same magnitude is applied to the selected fractional order model system (FOS) and obtained response was taken as P(t). The coefficients and fractional powers of FOS were adjusted until the least square error between C m (t) and P(t) was near zero. The curve fit of step responses of FOS and IOS is shown in Figure 7.2. The parameters of IOS and FOS at the operating point of 2cm are listed in Table 7. and Table 7.2 respectively..35 Curve Fitting Method FOS FOPDT Time(sec) x 4 Figure 7.2 Step responses of FOS and IOS at the operating point of 2cm Table 7. Parameters of IOS at the operating point of 2cm K d
9 27 Table 7.2 Parameters of FOS at the operating point of 2cm a 2 a a point of 2 cm is The resultant fractional order transfer function at the operating P (s) = e 8s s.5s (7.5) Second Method Alternatively the dead time of FOPDT model was approximated by Pade s approximation method. The resultant transfer function took the following form. C m (s) = k s 2 2 d d s s (7.6) Then the same least square method was applied to obtain the non commensurate FOTF model. The modeling parameters a, a, a 2,, and 2 of FOS were adjusted until the least square error between the step response of FOPDT model and the step response of fractional order system was almost zero. The step responses of IOS (C m (t)) and FOS (P(t)) at different operating points are shown in figures from Figure 7.3 to Figure 7.9.
10 P(t) Cm(t) Figure 7.3 Step responses of FOS and IOS at the operating point of 5.75cm The least square error between the reaction curves is.579. The corresponding FOTF at the operating point of 5.75 cm is G(s) =.7.s.2s (7.7) 2 P(t) Cm(t).5.5 Figure Step responses of FOS and IOS at the operating point of 3.5 cm
11 29 The least square error between the reaction curves is The corresponding FOTF at the operating point of 3.5 cm is G(s) = 4.7s.9 3.5s (7.8) P(t) Cm(t) Figure 7.5 Step responses of FOS and IOS at the operating point of 2.75 cm The least square error between the reaction curves is.54. The corresponding FOTF at the operating of 2.75 cm is G(s) =.8 35s 6s (7.9)
12 P(t) Cm(t) Figure 7.6 Step responses of FOS and IOS at the operating point of 27.25cm The least square error between the reaction curves is.975. The corresponding FOTF at the operating point of cm is G(s) =.8 87s 6s (7.2) P(t) cm(t) Figure 7.7 Step responses of FOS and IOS at the operating point of 32cm
13 3 The least square error between the reaction curves is The corresponding FOTF at the operating point of 32 cm is G(s) =.8 5s 6s (7.2) P(t) Cm(t) Figure 7.8 Step responses of FOS and IOS at the operating point of cm The least square error between the reaction curves is The corresponding FOTF at the operating point of cm is G(s) =.8 255s 6s (7.22)
14 P(t) Cm(t) Figure 7.9 Step responses of FOS and IOS at the operating point of cm The least square error between the reaction curves is The corresponding FOTF at the operating point of cm is G(s) =.8 46s 6s (7.23) 7.3 TUNING OF FOPI CONTROLLER FOR FRACTIONAL ORDER SYSTEM If the process is modeled as a FOS then the controller must be FOC. In fractional order controllers we have 3 choices that are FOPI, FOPD and FOPID. Based on the number of tuning parameters either the first three or all five constraints of the following can be considered for calculating the tuning parameters of the fractional order controller. The conditions should be specified by the user.
15 33. Phase margin constraint, Arg G j c Arg Gc j c Arg P j c m (7.24) 2. Gain crossover frequency constraint G j G j P j (7.25) c c c c 3. Robustness to loop gain variation constraint, which demands that the phase derivative with respect to the frequency is zero, namely, the phase Bode plot is flat, around the gain crossover frequency c. It means that the system is robust to loop gain changes and the overshoots of the responses are almost the same, d Arg G j d c (7.26) 4. To reject high-frequency noise, the closed loop transfer function must have a small magnitude at high frequencies hence, at some specified frequency h, its magnitude is to be less than some specified gain H. C( h) G( h) C( ) G( ) h h H (7.27)
16 34 5. To reject output disturbances and closely follow the references, the sensitivity function must have a small magnitude at low frequencies. Hence, at some specified frequency l, its magnitude is to be less than some specified gain N: C( ) G( ) l l N (7.28) A fractional order transfer function was taken from the literature (Ying Luo et al 2). They had designed FOPI controller for the FOTF. The same FOTF was considered with the same specifications. The FOPID controller was designed for a phase margin of 5degrees, gain crossover frequency of rad/sec, H of db and N of 2dB. The tuning parameters proportional gain K p, integral gain K i, derivative gain K d, integral power and derivative power are found using fmincon optimization function. The range of and is selected as to 2. considered The fractional order system with the following FOTF was P(s).4s.5 (7.29) The fractional order PID controller was tuned based on optimization of all the five constraints. controller is The transfer function of corresponding fractional order PID
17 G (s).8.s (7.3) c.2 s The closed loop responses of FOPI and FOPID controllers were compared and the responses are shown in Figure 7. Comparisons of performance criteria are listed in Table 7.3. The robustness of the controller to the parameter (either process or controller) changes was checked by changing the proportional gain of the FOPID controller and the responses for various values of gains are shown in Figure 7.. From the simulation results it was observed that FOPID controller did not make a great change compared to FOPI controller. Since FOPI controller only needs tuning of three parameters, FOPI controller was selected for FOS in this research work..4.2 FOPID FOPI r(t) Figure 7. Closed loop step response of FOPID and FOPI controllers with FOS
18 gain=k*.9 gain=(.) gain= Figure 7. Robustness checking of FOPID controller with FOS Table 7.3 Comparison of performance indices of FOPID and FOPI controllers Controller ISE IAE ITAE FOPID FOPI The three parameters (K p, K I and ) of fractional order PI controller were tuned based on the afore mentioned first three constraints. The FOPI controller was tuned for the phase cross over frequency of.43 rad / sec and phase margin of 2deg. The tuning parameters of resultant FOPI controller are listed in table 7.4.
19 37 Table 7.4 Tuning parameters of FOPI controller K p K i The transfer function of tuned fractional order PI controller for the fractional order model is, C ( s) s (7.3) With these tuning parameters the FOPI controller is connected in closed loop with FOS. The closed loop step responses of FOS with FOPI controller and IOS with IOPID controller are shown in Figure 7.2. The performance criteria are listed in table 7.5. COMPARISON OF CLOSED LOOP RESPONSE IOPID FOR FOPDT FOPI FOR FOS SETPOINT TIME(sec) Figure 7.2 Closed loop step responses of FOS with FOPI controller and IOS with IOPID controller at the operating point of 2cm
20 38 Table 7.5 Comparison of performance criteria of FOS with FOPI controller and IOS with IOPID controller Controller Maximum Peak Overshoot (%) Settling Time (sec) ISE IOPID FOPI The above simulation results show that the fractional order system with fractional order proportional and integral controller results no overshoot, less ISE and settling time when compared to integer order modeling and control. The tuning parameters of IOPID controllers for FOPDT models at different operating points are listed in Table 7.6. The tuning parameters of FOPI controllers for the FOS models obtained using second method are listed in Table 7.7. The closed loop step responses of FOS with FOPI controller and IOS with IOPID controller are shown in figures from Figure 7.3 to Figure 7.9.
21 39 Table 7.6 Tuning parameters of IOPID controller for Integer Order Systems Level in cm Transfer function.699e.99s.554s.84s.97e s.67s 3.3e 2.823s.49s 3.843e 2.883s.5s e 28.49s.49s 5.45e 39.57s 6.393e.33s 62.77s K c K i K d
22 4 Table 7.7 Tuning parameters of FOPI controller for Fractional Order Systems Level in cm Transfer function K c K i s.2s s.9 3.5s s 6s s 6s s.8 6s s.8 6s s 6s
23 4 2.5 r(t) Ci(t) Cf(t) Figure 7.3 Step responses of FOS with FOPI controller and IOS with IOPID controller at 5.75cm.5 r(t) Ci(t) Cf(t) Figure 7.4 Step responses of FOS with FOPI controller and IOS with IOPID controller 3.5 cm
24 r(t) Ci(t) Cf(t) Figure 7.5 Step responses of FOS with FOPI controller and IOS with IOPID controller at 2.75 cm 2.5 r(t) Ci(t) Cf(t) Figure 7.6 Step responses of FOS with FOPI controller and IOS with IOPID controller at cm
25 r(t) Ci(t) Cf(t) Figure 7.7 Step responses of FOS with FOPI controller and IOS with IOPID controller at 32 cm r(t) Ci(t) Cf(t) Figure 7.8 Step responses of FOS with FOPI controller and IOS with IOPID controller at cm
26 r(t) Ci(t) Cf(t) Figure 7.9 Step responses of FOS with FOPI controller and IOS with IOPID controller at cm The performance criteria like M p, t s, ISE, IAE and ITAE of FOS with FOPI and IOS with IOPID controllers are listed in Table 7.8.
27 45 Table 7.8 Comparison of performance criteria of FOS with FOPI and IOS with IOPID controllers Level (Cm) Controller M p (%) t s (sec) ISE IAE ITAE IOPID FOPI IOPID FOPI IOPID FOPI IOPID FOPI IOPID FOPI IOPID FOPI IOPID FOPI It is observed from the above results that the closed loop response of FOS with corresponding FOPI controller is performing well in all aspects compared to IOS with IOPID controller. 7.4 EXPERIMENTAL RESULTS A set point of 2 cm was given to the experimental setup when it was connected in closed loop with the FOPI controller. The tuning parameters of FOPI controller corresponding to the FOS modeled using first method were used. After it reached the steady state a disturbance was introduced through a sudden change in pump speed which is assumed due to voltage
28 46 fluctuation and once again the system was allowed to reach the steady state. The servo and regulatory responses are shown in Figure 7.2. The error graph corresponding to this response is shown in Figure r(t) c(t) d(t) Figure 7.2 Servo and regulatory response of FOPI controller when the set point is 2cm Figure 7.2 Error graph when the set point is 2 cm
29 47 The closed loop response of FOPI controller was compared with the closed loop response of IOPI controller. Some of the time domain specifications are listed in Table 7.9 to show the efficiency of the modeling of the experimental set up as a FOS with properly tuned FOPI controller over integer order modeling with integer order controller. Table 7.9 Comparison of performance criteria of FOPI and IOPI controllers on experimental setup when the set point is 2 cm Controller Rise time (sec) Peak time (sec) Peak overshoot (%) Settling time(sec) ISE ZN-PI FOPI From the comparisons made it is observed that even though the fractional order modeling and control shows only small improvements in rise time, peak time and peak over shoot there is a great improvement in settling time which is more important. A set point of 32 cm was given to the experimental setup when it was connected in closed loop with the FOPI controller. The tuning parameters of FOPI controller corresponding to the FOS modeled using second method were used. After it reached the steady state a disturbance was introduced through a sudden change in pump speed and once again the system was allowed to reach the steady state. The servo and regulatory responses with IOPI controller tuned based on ZN and FOPI controller are shown in Figure 7.22 and Figure 7.23 respectively.
30 r(t) c(t) d(t) Figure 7.22 Servo and regulatory response of IOPI control system when the set point is 32cm 4 3 c(t) d(t) r(t) Figure 7.23 Servo and regulatory response of FOPI control system when the set point is 32cm
31 49 The closed loop servo and regulatory responses of FOPI controller and IOPI controller were compared. Some of the time domain specifications are listed in Table 7.9 to show the efficiency of the modeling of the experimental set up as a FOS with properly tuned FOPI controller over integer order modeling with integer order controller. Table 7. Comparison of performance criteria of FOPI and IOPI controllers on experimental setup when the set point is 32 cm Controller Rise time (sec) Peak time (sec) Peak overshoot (%) Settling time(sec) ISE ZN-PI FOPI When the response of FOPI controller was compared with IOPI controller on the experimental setup, it was observed that the fractional order modeling and control shows very good improvements in rise time, peak time, over shoot and settling time. 7.5 CONCLUSIONS The spherical tank was modeled as non commensurate fractional order systems with and without dead time. From both simulation and experimental results it was observed that fractional order modeling and control improves the performance of the control system over integer order modeling and control. This was proved qualitatively as well as quantitatively.
32 5 It is concluded that among the two proposed methods of fractional order modeling, the FOS model developed using second method, with properly tuned FOPI controller produced good results in terms of performance criteria like rise time, maximum peak over shoot, settling time and ISE etc over the FOS, modeled by first method with properly tuned fractional order controllers.
Robust PID and Fractional PI Controllers Tuning for General Plant Model
2 مجلة البصرة للعلوم الهندسية-المجلد 5 العدد 25 Robust PID and Fractional PI Controllers Tuning for General Plant Model Dr. Basil H. Jasim. Department of electrical Engineering University of Basrah College
More informationFeedback Control of Linear SISO systems. Process Dynamics and Control
Feedback Control of Linear SISO systems Process Dynamics and Control 1 Open-Loop Process The study of dynamics was limited to open-loop systems Observe process behavior as a result of specific input signals
More informationDesign and Tuning of Fractional-order PID Controllers for Time-delayed Processes
Design and Tuning of Fractional-order PID Controllers for Time-delayed Processes Emmanuel Edet Technology and Innovation Centre University of Strathclyde 99 George Street Glasgow, United Kingdom emmanuel.edet@strath.ac.uk
More informationKINGS COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRONICS AND COMMUNICATION ENGINEERING
KINGS COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRONICS AND COMMUNICATION ENGINEERING QUESTION BANK SUB.NAME : CONTROL SYSTEMS BRANCH : ECE YEAR : II SEMESTER: IV 1. What is control system? 2. Define open
More informationMAS107 Control Theory Exam Solutions 2008
MAS07 CONTROL THEORY. HOVLAND: EXAM SOLUTION 2008 MAS07 Control Theory Exam Solutions 2008 Geir Hovland, Mechatronics Group, Grimstad, Norway June 30, 2008 C. Repeat question B, but plot the phase curve
More informationMEM 355 Performance Enhancement of Dynamical Systems
MEM 355 Performance Enhancement of Dynamical Systems Frequency Domain Design Intro Harry G. Kwatny Department of Mechanical Engineering & Mechanics Drexel University /5/27 Outline Closed Loop Transfer
More informationCHBE320 LECTURE XI CONTROLLER DESIGN AND PID CONTOLLER TUNING. Professor Dae Ryook Yang
CHBE320 LECTURE XI CONTROLLER DESIGN AND PID CONTOLLER TUNING Professor Dae Ryook Yang Spring 2018 Dept. of Chemical and Biological Engineering 11-1 Road Map of the Lecture XI Controller Design and PID
More informationOutline. Classical Control. Lecture 1
Outline Outline Outline 1 Introduction 2 Prerequisites Block diagram for system modeling Modeling Mechanical Electrical Outline Introduction Background Basic Systems Models/Transfers functions 1 Introduction
More informationDr Ian R. Manchester Dr Ian R. Manchester AMME 3500 : Review
Week Date Content Notes 1 6 Mar Introduction 2 13 Mar Frequency Domain Modelling 3 20 Mar Transient Performance and the s-plane 4 27 Mar Block Diagrams Assign 1 Due 5 3 Apr Feedback System Characteristics
More informationCHAPTER 7 MODELING AND CONTROL OF SPHERICAL TANK LEVEL PROCESS 7.1 INTRODUCTION
141 CHAPTER 7 MODELING AND CONTROL OF SPHERICAL TANK LEVEL PROCESS 7.1 INTRODUCTION In most of the industrial processes like a water treatment plant, paper making industries, petrochemical industries,
More information(b) A unity feedback system is characterized by the transfer function. Design a suitable compensator to meet the following specifications:
1. (a) The open loop transfer function of a unity feedback control system is given by G(S) = K/S(1+0.1S)(1+S) (i) Determine the value of K so that the resonance peak M r of the system is equal to 1.4.
More informationCHAPTER 5 ROBUSTNESS ANALYSIS OF THE CONTROLLER
114 CHAPTER 5 ROBUSTNESS ANALYSIS OF THE CONTROLLER 5.1 INTRODUCTION Robust control is a branch of control theory that explicitly deals with uncertainty in its approach to controller design. It also refers
More informationChapter 2. Classical Control System Design. Dutch Institute of Systems and Control
Chapter 2 Classical Control System Design Overview Ch. 2. 2. Classical control system design Introduction Introduction Steady-state Steady-state errors errors Type Type k k systems systems Integral Integral
More informationControl Systems. EC / EE / IN. For
Control Systems For EC / EE / IN By www.thegateacademy.com Syllabus Syllabus for Control Systems Basic Control System Components; Block Diagrammatic Description, Reduction of Block Diagrams. Open Loop
More informationLearn2Control Laboratory
Learn2Control Laboratory Version 3.2 Summer Term 2014 1 This Script is for use in the scope of the Process Control lab. It is in no way claimed to be in any scientific way complete or unique. Errors should
More informationarxiv: v1 [cs.sy] 30 Nov 2017
Disturbance Observer based Control of Integrating Processes with Dead-Time using PD controller Sujay D. Kadam SysIDEA Lab, IIT Gandhinagar, India. arxiv:1711.11250v1 [cs.sy] 30 Nov 2017 Abstract The work
More informationYTÜ Mechanical Engineering Department
YTÜ Mechanical Engineering Department Lecture of Special Laboratory of Machine Theory, System Dynamics and Control Division Coupled Tank 1 Level Control with using Feedforward PI Controller Lab Report
More informationPrüfung Regelungstechnik I (Control Systems I) Übersetzungshilfe / Translation aid (English) To be returned at the end of the exam!
Prüfung Regelungstechnik I (Control Systems I) Prof. Dr. Lino Guzzella 29. 8. 2 Übersetzungshilfe / Translation aid (English) To be returned at the end of the exam! Do not mark up this translation aid
More informationExam. 135 minutes + 15 minutes reading time
Exam January 23, 27 Control Systems I (5-59-L) Prof. Emilio Frazzoli Exam Exam Duration: 35 minutes + 5 minutes reading time Number of Problems: 45 Number of Points: 53 Permitted aids: Important: 4 pages
More informationCHAPTER 3 TUNING METHODS OF CONTROLLER
57 CHAPTER 3 TUNING METHODS OF CONTROLLER 3.1 INTRODUCTION This chapter deals with a simple method of designing PI and PID controllers for first order plus time delay with integrator systems (FOPTDI).
More informationTuning of fractional PI controllers for fractional order system models with and without time delays
2 American Control Conference Marriott Waterfront, Baltimore, MD, USA June 3-July 2, 2 FrC2. Tuning of fractional PI controllers for fractional order system models with and without time delays Anuj Narang,
More informationECSE 4962 Control Systems Design. A Brief Tutorial on Control Design
ECSE 4962 Control Systems Design A Brief Tutorial on Control Design Instructor: Professor John T. Wen TA: Ben Potsaid http://www.cat.rpi.edu/~wen/ecse4962s04/ Don t Wait Until The Last Minute! You got
More informationÜbersetzungshilfe / Translation aid (English) To be returned at the end of the exam!
Prüfung Regelungstechnik I (Control Systems I) Prof. Dr. Lino Guzzella 9. 8. 2 Übersetzungshilfe / Translation aid (English) To be returned at the end of the exam! Do not mark up this translation aid -
More informationECE 388 Automatic Control
Lead Compensator and PID Control Associate Prof. Dr. of Mechatronics Engineeering Çankaya University Compulsory Course in Electronic and Communication Engineering Credits (2/2/3) Course Webpage: http://ece388.cankaya.edu.tr
More informationAutomatic Control 2. Loop shaping. Prof. Alberto Bemporad. University of Trento. Academic year
Automatic Control 2 Loop shaping Prof. Alberto Bemporad University of Trento Academic year 21-211 Prof. Alberto Bemporad (University of Trento) Automatic Control 2 Academic year 21-211 1 / 39 Feedback
More informationLecture 5: Linear Systems. Transfer functions. Frequency Domain Analysis. Basic Control Design.
ISS0031 Modeling and Identification Lecture 5: Linear Systems. Transfer functions. Frequency Domain Analysis. Basic Control Design. Aleksei Tepljakov, Ph.D. September 30, 2015 Linear Dynamic Systems Definition
More informationEE 422G - Signals and Systems Laboratory
EE 4G - Signals and Systems Laboratory Lab 9 PID Control Kevin D. Donohue Department of Electrical and Computer Engineering University of Kentucky Lexington, KY 40506 April, 04 Objectives: Identify the
More informationProcess Modelling, Identification, and Control
Jan Mikles Miroslav Fikar 2008 AGI-Information Management Consultants May be used for personal purporses only or by libraries associated to dandelon.com network. Process Modelling, Identification, and
More informationMAE 143B - Homework 9
MAE 43B - Homework 9 7.2 2 2 3.8.6.4.2.2 9 8 2 2 3 a) G(s) = (s+)(s+).4.6.8.2.2.4.6.8. Polar plot; red for negative ; no encirclements of, a.s. under unit feedback... 2 2 3. 4 9 2 2 3 h) G(s) = s+ s(s+)..2.4.6.8.2.4
More informationAN INTRODUCTION TO THE CONTROL THEORY
Open-Loop controller An Open-Loop (OL) controller is characterized by no direct connection between the output of the system and its input; therefore external disturbance, non-linear dynamics and parameter
More informationLecture 12. Upcoming labs: Final Exam on 12/21/2015 (Monday)10:30-12:30
289 Upcoming labs: Lecture 12 Lab 20: Internal model control (finish up) Lab 22: Force or Torque control experiments [Integrative] (2-3 sessions) Final Exam on 12/21/2015 (Monday)10:30-12:30 Today: Recap
More informationExperimental Study of Fractional Order Proportional Integral (FOPI) Controller for Water Level Control
Proceedings of the 47th IEEE Conference on Decision and Control Cancun, Mexico, Dec. 9-11, 2008 Experimental Study of Fractional Order Proportional Integral (FOPI) Controller for Water Level Control Varsha
More informationModel-based PID tuning for high-order processes: when to approximate
Proceedings of the 44th IEEE Conference on Decision and Control, and the European Control Conference 25 Seville, Spain, December 2-5, 25 ThB5. Model-based PID tuning for high-order processes: when to approximate
More informationAnalysis of SISO Control Loops
Chapter 5 Analysis of SISO Control Loops Topics to be covered For a given controller and plant connected in feedback we ask and answer the following questions: Is the loop stable? What are the sensitivities
More informationControl Systems I. Lecture 6: Poles and Zeros. Readings: Emilio Frazzoli. Institute for Dynamic Systems and Control D-MAVT ETH Zürich
Control Systems I Lecture 6: Poles and Zeros Readings: Emilio Frazzoli Institute for Dynamic Systems and Control D-MAVT ETH Zürich October 27, 2017 E. Frazzoli (ETH) Lecture 6: Control Systems I 27/10/2017
More informationControl Systems I Lecture 10: System Specifications
Control Systems I Lecture 10: System Specifications Readings: Guzzella, Chapter 10 Emilio Frazzoli Institute for Dynamic Systems and Control D-MAVT ETH Zürich November 24, 2017 E. Frazzoli (ETH) Lecture
More informationA ROBUST STABILITY TEST PROCEDURE FOR A CLASS OF UNCERTAIN LTI FRACTIONAL ORDER SYSTEMS
International Carpathian Control Conference ICCC 22 MALENOVICE, CZECH REPUBLIC May 27-, 22 A ROBUST STABILITY TEST PROCEDURE FOR A CLASS OF UNCERTAIN LTI FRACTIONAL ORDER SYSTEMS Ivo PETRÁŠ, YangQuan CHEN
More informationEngraving Machine Example
Engraving Machine Example MCE44 - Fall 8 Dr. Richter November 24, 28 Basic Design The X-axis of the engraving machine has the transfer function G(s) = s(s + )(s + 2) In this basic example, we use a proportional
More informationSAMPLE SOLUTION TO EXAM in MAS501 Control Systems 2 Autumn 2015
FACULTY OF ENGINEERING AND SCIENCE SAMPLE SOLUTION TO EXAM in MAS501 Control Systems 2 Autumn 2015 Lecturer: Michael Ruderman Problem 1: Frequency-domain analysis and control design (15 pt) Given is a
More informationLecture 7:Time Response Pole-Zero Maps Influence of Poles and Zeros Higher Order Systems and Pole Dominance Criterion
Cleveland State University MCE441: Intr. Linear Control Lecture 7:Time Influence of Poles and Zeros Higher Order and Pole Criterion Prof. Richter 1 / 26 First-Order Specs: Step : Pole Real inputs contain
More informationYTÜ Mechanical Engineering Department
YTÜ Mechanical Engineering Department Lecture of Special Laboratory of Machine Theory, System Dynamics and Control Division Coupled Tank 1 Level Control with using Feedforward PI Controller Lab Date: Lab
More informationsc Control Systems Design Q.1, Sem.1, Ac. Yr. 2010/11
sc46 - Control Systems Design Q Sem Ac Yr / Mock Exam originally given November 5 9 Notes: Please be reminded that only an A4 paper with formulas may be used during the exam no other material is to be
More informationVALLIAMMAI ENGINEERING COLLEGE
VALLIAMMAI ENGINEERING COLLEGE SRM Nagar, Kattankulathur 603 203 DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK V SEMESTER IC650 CONTROL SYSTEMS Regulation 203 Academic Year 207 8 Prepared
More informationCHAPTER 7 STEADY-STATE RESPONSE ANALYSES
CHAPTER 7 STEADY-STATE RESPONSE ANALYSES 1. Introduction The steady state error is a measure of system accuracy. These errors arise from the nature of the inputs, system type and from nonlinearities of
More informationÜbersetzungshilfe / Translation aid (English) To be returned at the end of the exam!
Prüfung Regelungstechnik I (Control Systems I) Prof. Dr. Lino Guzzella 3.. 24 Übersetzungshilfe / Translation aid (English) To be returned at the end of the exam! Do not mark up this translation aid -
More informationRobust fixed-order H Controller Design for Spectral Models by Convex Optimization
Robust fixed-order H Controller Design for Spectral Models by Convex Optimization Alireza Karimi, Gorka Galdos and Roland Longchamp Abstract A new approach for robust fixed-order H controller design by
More informationClassify a transfer function to see which order or ramp it can follow and with which expected error.
Dr. J. Tani, Prof. Dr. E. Frazzoli 5-059-00 Control Systems I (Autumn 208) Exercise Set 0 Topic: Specifications for Feedback Systems Discussion: 30.. 208 Learning objectives: The student can grizzi@ethz.ch,
More informationImproved Identification and Control of 2-by-2 MIMO System using Relay Feedback
CEAI, Vol.17, No.4 pp. 23-32, 2015 Printed in Romania Improved Identification and Control of 2-by-2 MIMO System using Relay Feedback D.Kalpana, T.Thyagarajan, R.Thenral Department of Instrumentation Engineering,
More information(a) Find the transfer function of the amplifier. Ans.: G(s) =
126 INTRDUCTIN T CNTR ENGINEERING 10( s 1) (a) Find the transfer function of the amplifier. Ans.: (. 02s 1)(. 001s 1) (b) Find the expected percent overshoot for a step input for the closed-loop system
More informationClosed Loop Identification Of A First Order Plus Dead Time Process Model Under PI Control
Dublin Institute of Technology RROW@DIT Conference papers School of Electrical and Electronic Engineering -6- Closed Loop Identification Of First Order Plus Dead Time Process Model Under PI Control Tony
More informationELECTRONICS & COMMUNICATIONS DEP. 3rd YEAR, 2010/2011 CONTROL ENGINEERING SHEET 5 Lead-Lag Compensation Techniques
CAIRO UNIVERSITY FACULTY OF ENGINEERING ELECTRONICS & COMMUNICATIONS DEP. 3rd YEAR, 00/0 CONTROL ENGINEERING SHEET 5 Lead-Lag Compensation Techniques [] For the following system, Design a compensator such
More informationEC6405 - CONTROL SYSTEM ENGINEERING Questions and Answers Unit - I Control System Modeling Two marks 1. What is control system? A system consists of a number of components connected together to perform
More informationIntro to Frequency Domain Design
Intro to Frequency Domain Design MEM 355 Performance Enhancement of Dynamical Systems Harry G. Kwatny Department of Mechanical Engineering & Mechanics Drexel University Outline Closed Loop Transfer Functions
More informationUNIVERSITY OF BOLTON SCHOOL OF ENGINEERING BENG (HONS) IN BIOMEDICAL ENGINEERING SEMESTER 1 EXAMINATION 2017/2018 ADVANCED BIOMECHATRONIC SYSTEMS
ENG0016 UNIVERSITY OF BOLTON SCHOOL OF ENGINEERING BENG (HONS) IN BIOMEDICAL ENGINEERING SEMESTER 1 EXAMINATION 2017/2018 ADVANCED BIOMECHATRONIC SYSTEMS MODULE NO: BME6003 Date: Friday 19 January 2018
More informationLinear State Feedback Controller Design
Assignment For EE5101 - Linear Systems Sem I AY2010/2011 Linear State Feedback Controller Design Phang Swee King A0033585A Email: king@nus.edu.sg NGS/ECE Dept. Faculty of Engineering National University
More informationÜbersetzungshilfe / Translation aid (English) To be returned at the end of the exam!
Prüfung Regelungstechnik I (Control Systems I) Prof. Dr. Lino Guzzella 3. 8. 24 Übersetzungshilfe / Translation aid (English) To be returned at the end of the exam! Do not mark up this translation aid
More informationDesign and Implementation of Two-Degree-of-Freedom Nonlinear PID Controller for a Nonlinear Process
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-issn: 2278-1676,p-ISSN: 23-3331, Volume 9, Issue 3 Ver. III (May Jun. 14), PP 59-64 Design and Implementation of Two-Degree-of-Freedom
More informationDavid A. Cornelio Sosa. A thesis submitted in partial fulfillment of the requirements for the degree MASTER OF SCIENCE. Electrical Engineering
AN EFFICIENCY-MOTIVATED ATTACK AGAINST VEHICLES IN A PLATOON: LOCAL VEHICLE CONTROL, PLATOON CONTROL STRATEGIES, AND DRIVE TRAIN TECHNOLOGIES CONSIDERATIONS by David A. Cornelio Sosa A thesis submitted
More informationComparative Study of Controllers for a Variable Area MIMO Interacting NonLinear System
Comparative Study of Controllers for a Variable Area MIMO Interacting NonLinear System Priya Chandrasekar*, Lakshmi Ponnusamy #2 *, #2 Department of Electrical and Electronics Engineering, CE, Anna University
More informationDr Ian R. Manchester Dr Ian R. Manchester AMME 3500 : Root Locus
Week Content Notes 1 Introduction 2 Frequency Domain Modelling 3 Transient Performance and the s-plane 4 Block Diagrams 5 Feedback System Characteristics Assign 1 Due 6 Root Locus 7 Root Locus 2 Assign
More informationINTRODUCTION TO DIGITAL CONTROL
ECE4540/5540: Digital Control Systems INTRODUCTION TO DIGITAL CONTROL.: Introduction In ECE450/ECE550 Feedback Control Systems, welearnedhow to make an analog controller D(s) to control a linear-time-invariant
More informationControl System Design
ELEC ENG 4CL4: Control System Design Notes for Lecture #11 Wednesday, January 28, 2004 Dr. Ian C. Bruce Room: CRL-229 Phone ext.: 26984 Email: ibruce@mail.ece.mcmaster.ca Relative Stability: Stability
More informationINSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad
INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad - 500 043 Electrical and Electronics Engineering TUTORIAL QUESTION BAN Course Name : CONTROL SYSTEMS Course Code : A502 Class : III
More informationTUNING-RULES FOR FRACTIONAL PID CONTROLLERS
TUNING-RULES FOR FRACTIONAL PID CONTROLLERS Duarte Valério, José Sá da Costa Technical Univ. of Lisbon Instituto Superior Técnico Department of Mechanical Engineering GCAR Av. Rovisco Pais, 49- Lisboa,
More informationFEEDBACK CONTROL SYSTEMS
FEEDBAC CONTROL SYSTEMS. Control System Design. Open and Closed-Loop Control Systems 3. Why Closed-Loop Control? 4. Case Study --- Speed Control of a DC Motor 5. Steady-State Errors in Unity Feedback Control
More informationUniversity of Science and Technology, Sudan Department of Chemical Engineering.
ISO 91:28 Certified Volume 3, Issue 6, November 214 Design and Decoupling of Control System for a Continuous Stirred Tank Reactor (CSTR) Georgeous, N.B *1 and Gasmalseed, G.A, Abdalla, B.K (1-2) University
More informationTime Response Analysis (Part II)
Time Response Analysis (Part II). A critically damped, continuous-time, second order system, when sampled, will have (in Z domain) (a) A simple pole (b) Double pole on real axis (c) Double pole on imaginary
More informationÜbersetzungshilfe / Translation aid (English) To be returned at the end of the exam!
Prüfung Regelungstechnik I (Control Systems I) Prof. Dr. Lino Guzzella 5. 2. 2 Übersetzungshilfe / Translation aid (English) To be returned at the end of the exam! Do not mark up this translation aid -
More informationDigital Control: Summary # 7
Digital Control: Summary # 7 Proportional, integral and derivative control where K i is controller parameter (gain). It defines the ratio of the control change to the control error. Note that e(k) 0 u(k)
More informationR a) Compare open loop and closed loop control systems. b) Clearly bring out, from basics, Force-current and Force-Voltage analogies.
SET - 1 II B. Tech II Semester Supplementary Examinations Dec 01 1. a) Compare open loop and closed loop control systems. b) Clearly bring out, from basics, Force-current and Force-Voltage analogies..
More informationFractional-order Modeling and Control of Dynamic Systems
THESIS ON INFORMATICS AND SYSTEM ENGINEERING C14 Fractional-order Modeling and Control of Dynamic Systems ALEKSEI TEPLJAKOV TALLINN UNIVERSITY OF TECHNOLOGY Faculty of Information Technology Department
More informationEC CONTROL SYSTEM UNIT I- CONTROL SYSTEM MODELING
EC 2255 - CONTROL SYSTEM UNIT I- CONTROL SYSTEM MODELING 1. What is meant by a system? It is an arrangement of physical components related in such a manner as to form an entire unit. 2. List the two types
More informationAutomatic Control (MSc in Mechanical Engineering) Lecturer: Andrea Zanchettin Date: Student ID number... Signature...
Automatic Control (MSc in Mechanical Engineering) Lecturer: Andrea Zanchettin Date: 29..23 Given and family names......................solutions...................... Student ID number..........................
More informationIC6501 CONTROL SYSTEMS
DHANALAKSHMI COLLEGE OF ENGINEERING CHENNAI DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING YEAR/SEMESTER: II/IV IC6501 CONTROL SYSTEMS UNIT I SYSTEMS AND THEIR REPRESENTATION 1. What is the mathematical
More informationSimulation Study on Pressure Control using Nonlinear Input/Output Linearization Method and Classical PID Approach
Simulation Study on Pressure Control using Nonlinear Input/Output Linearization Method and Classical PID Approach Ufuk Bakirdogen*, Matthias Liermann** *Institute for Fluid Power Drives and Controls (IFAS),
More informationClosed-Loop Identification of Fractionalorder Models using FOMCON Toolbox for MATLAB
Closed-Loop Identification of Fractionalorder Models using FOMCON Toolbox for MATLAB Aleksei Tepljakov, Eduard Petlenkov, Juri Belikov October 7, 2014 Motivation, Contribution, and Outline The problem
More information100 (s + 10) (s + 100) e 0.5s. s 100 (s + 10) (s + 100). G(s) =
1 AME 3315; Spring 215; Midterm 2 Review (not graded) Problems: 9.3 9.8 9.9 9.12 except parts 5 and 6. 9.13 except parts 4 and 5 9.28 9.34 You are given the transfer function: G(s) = 1) Plot the bode plot
More informationDr Ian R. Manchester
Week Content Notes 1 Introduction 2 Frequency Domain Modelling 3 Transient Performance and the s-plane 4 Block Diagrams 5 Feedback System Characteristics Assign 1 Due 6 Root Locus 7 Root Locus 2 Assign
More informationVALLIAMMAI ENGINEERING COLLEGE SRM Nagar, Kattankulathur
VALLIAMMAI ENGINEERING COLLEGE SRM Nagar, Kattankulathur 603 203. DEPARTMENT OF ELECTRONICS & COMMUNICATION ENGINEERING SUBJECT QUESTION BANK : EC6405 CONTROL SYSTEM ENGINEERING SEM / YEAR: IV / II year
More information1 An Overview and Brief History of Feedback Control 1. 2 Dynamic Models 23. Contents. Preface. xiii
Contents 1 An Overview and Brief History of Feedback Control 1 A Perspective on Feedback Control 1 Chapter Overview 2 1.1 A Simple Feedback System 3 1.2 A First Analysis of Feedback 6 1.3 Feedback System
More informationDesign and Implementation of Sliding Mode Controller using Coefficient Diagram Method for a nonlinear process
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-issn: 2278-1676,p-ISSN: 2320-3331, Volume 7, Issue 5 (Sep. - Oct. 2013), PP 19-24 Design and Implementation of Sliding Mode Controller
More informationMEM 355 Performance Enhancement of Dynamical Systems
MEM 355 Performance Enhancement of Dynamical Systems Frequency Domain Design Harry G. Kwatny Department of Mechanical Engineering & Mechanics Drexel University 5/8/25 Outline Closed Loop Transfer Functions
More informationSystems Analysis and Control
Systems Analysis and Control Matthew M. Peet Arizona State University Lecture 21: Stability Margins and Closing the Loop Overview In this Lecture, you will learn: Closing the Loop Effect on Bode Plot Effect
More informationControls Problems for Qualifying Exam - Spring 2014
Controls Problems for Qualifying Exam - Spring 2014 Problem 1 Consider the system block diagram given in Figure 1. Find the overall transfer function T(s) = C(s)/R(s). Note that this transfer function
More informationFATIMA MICHAEL COLLEGE OF ENGINEERING & TECHNOLOGY
FATIMA MICHAEL COLLEGE OF ENGINEERING & TECHNOLOGY Senkottai Village, Madurai Sivagangai Main Road, Madurai - 625 020. An ISO 9001:2008 Certified Institution DEPARTMENT OF ELECTRONICS AND COMMUNICATION
More informationLecture 5 Classical Control Overview III. Dr. Radhakant Padhi Asst. Professor Dept. of Aerospace Engineering Indian Institute of Science - Bangalore
Lecture 5 Classical Control Overview III Dr. Radhakant Padhi Asst. Professor Dept. of Aerospace Engineering Indian Institute of Science - Bangalore A Fundamental Problem in Control Systems Poles of open
More informationRobust Fractional Control An overview of the research activity carried on at the University of Brescia
Università degli Studi di Brescia Dipartimento di Ingegneria dell Informazione Robust Fractional Control An overview of the research activity carried on at the University of Brescia Fabrizio Padula and
More informationRichiami di Controlli Automatici
Richiami di Controlli Automatici Gianmaria De Tommasi 1 1 Università degli Studi di Napoli Federico II detommas@unina.it Ottobre 2012 Corsi AnsaldoBreda G. De Tommasi (UNINA) Richiami di Controlli Automatici
More informationCM 3310 Process Control, Spring Lecture 21
CM 331 Process Control, Spring 217 Instructor: Dr. om Co Lecture 21 (Back to Process Control opics ) General Control Configurations and Schemes. a) Basic Single-Input/Single-Output (SISO) Feedback Figure
More informationPositioning Servo Design Example
Positioning Servo Design Example 1 Goal. The goal in this design example is to design a control system that will be used in a pick-and-place robot to move the link of a robot between two positions. Usually
More informationDigital Control Systems
Digital Control Systems Lecture Summary #4 This summary discussed some graphical methods their use to determine the stability the stability margins of closed loop systems. A. Nyquist criterion Nyquist
More informationIMC based automatic tuning method for PID controllers in a Smith predictor configuration
Computers and Chemical Engineering 28 (2004) 281 290 IMC based automatic tuning method for PID controllers in a Smith predictor configuration Ibrahim Kaya Department of Electrical and Electronics Engineering,
More information] [ 200. ] 3 [ 10 4 s. [ ] s + 10 [ P = s [ 10 8 ] 3. s s (s 1)(s 2) series compensator ] 2. s command pre-filter [ 0.
EEE480 Exam 2, Spring 204 A.A. Rodriguez Rules: Calculators permitted, One 8.5 sheet, closed notes/books, open minds GWC 352, 965-372 Problem (Analysis of a Feedback System) Consider the feedback system
More informationCHAPTER 1 Basic Concepts of Control System. CHAPTER 6 Hydraulic Control System
CHAPTER 1 Basic Concepts of Control System 1. What is open loop control systems and closed loop control systems? Compare open loop control system with closed loop control system. Write down major advantages
More informationMAE143a: Signals & Systems (& Control) Final Exam (2011) solutions
MAE143a: Signals & Systems (& Control) Final Exam (2011) solutions Question 1. SIGNALS: Design of a noise-cancelling headphone system. 1a. Based on the low-pass filter given, design a high-pass filter,
More informationQuanser NI-ELVIS Trainer (QNET) Series: QNET Experiment #02: DC Motor Position Control. DC Motor Control Trainer (DCMCT) Student Manual
Quanser NI-ELVIS Trainer (QNET) Series: QNET Experiment #02: DC Motor Position Control DC Motor Control Trainer (DCMCT) Student Manual Table of Contents 1 Laboratory Objectives1 2 References1 3 DCMCT Plant
More information6.1 Sketch the z-domain root locus and find the critical gain for the following systems K., the closed-loop characteristic equation is K + z 0.
6. Sketch the z-domain root locus and find the critical gain for the following systems K (i) Gz () z 4. (ii) Gz K () ( z+ 9. )( z 9. ) (iii) Gz () Kz ( z. )( z ) (iv) Gz () Kz ( + 9. ) ( z. )( z 8. ) (i)
More informationProcess Control & Instrumentation (CH 3040)
First-order systems Process Control & Instrumentation (CH 3040) Arun K. Tangirala Department of Chemical Engineering, IIT Madras January - April 010 Lectures: Mon, Tue, Wed, Fri Extra class: Thu A first-order
More informationAuto-tuning Fractional Order Control of a Laboratory Scale Equipment
Auto-tuning Fractional Order Control of a Laboratory Scale Equipment Rusu-Both Roxana * and Dulf Eva-Henrietta Automation Department, Technical University of Cluj-Napoca, Memorandumului Street, No.28 Cluj-Napoca,
More informationResearch Article. World Journal of Engineering Research and Technology WJERT.
wjert, 2015, Vol. 1, Issue 1, 27-36 Research Article ISSN 2454-695X WJERT www.wjert.org COMPENSATOR TUNING FOR DISTURBANCE REJECTION ASSOCIATED WITH DELAYED DOUBLE INTEGRATING PROCESSES, PART I: FEEDBACK
More information