SHODEX. by Showa Denko K.K.

Size: px
Start display at page:

Download "SHODEX. by Showa Denko K.K."

Transcription

1 selectosil For Availability and Ordering nformation please contact your Phenomenex Technical Consultant. SHODEX Selectosil/ High efficiency polymer columns Excellent mechanical and chemical stability Wide application range High temperature GPC applications Nomenclature of Packing Materials PHM polyhydroxymethacrylate PMM polymethylmethacrylate PS polystyrene PVA polyvinyl alcohol S-DVB styrene-divinylbenzene co-polymer Separation Modes AFC affinity chromatography GPC gel permeation chromatography (organic-soluble SEC) GFC gel filtration chromatography (water-soluble SEC) HC hydrophobic interaction chromatography C ion chromatography EC ion-exchange chromatography EX ion-exclusion chromatography LEX ligand-exchange chromatography NPC normal phase chromatography P & A partition and adsorption chromatography RPC reversed phase chromatography SEC size-exclusion chromatography (includes GPC & GFC) Guide for Column Selection Molecular Separation Solubility Weight Mode Column Page over 000 under 000 SEC GPC KF , K , KD ,..., KF , KF-0.5 HQ-06L HQ SEC GPC KF , K , KD , LF-80,..., KF , KF-0 HQ-0.5L HQ RPC RSpak DE-, L, DM Sample over 000 SEC EC HC OHpak SB HQ, SUGAR KS , PROTEN KW EC QA-85, DEAE-85, SP-85, CM AXpak WA HC PH RPC RSpak RP AFFNTY AFpak...5 Waterinsoluble Watersoluble under 000 SEC SB HQ, SUGAR KS LEC SUGAR SC0, SP EX RSpak KC-8, SUGAR SH0, SUGAR SH8...6, 5 EC AXpak WA C C S-90 E, S-50 E, C -5A, Y-5, YK-, T RPC RSpak DE-6,, DS NPC SUGAR SZ55, RSpak DC-6...5, 7 AFFNTY AFpak...5 CHRAL ORpak CDBS, CDA, CDB, CDC HQ Phenomenex

2 Organic GPC Columns has a wide variety of columns for GPC (or SEC) using organic solvents. The columns are packed with porous S- DVB gels specially developed for GPC use. Five types of GPC columns packed in different solvents are available. Custom columns packed in other solvents, such as quinoline, o-dichlorobenzene, ethyl acetate, tetrachloroethane and dimethylacetamide are available upon request. Series name n-column solvent Applications GPC KF-800 series THF (tetrahydrofuran) General purpose GPC GPC K-800 series Chloroform General purpose GPC GPC KD-800 series DMF (dimethylformamide) Polar compounds such as melamine resin, phenolic resin, polyurethane and polyvinylpyrrolidone GPC LF-80 THF Wide linear molecular weight GPC HFP-800 series HFP (hexafluoroisopropanol) Engineering plastics such as polyamide (Nylon) and polybutylterephthalate at ordinary temperature GPC HT-800 series Toluene High temperature GPC up to 0 C GPC UT-800 series Toluene Ultra high temperature GPC up to 0 C. Polymer samples in which ultra-high molecular weight portion is included GPC KF-600 series THF Semi-micro GPC GPC KF-00HQ series THF Semi-micro GPC for organic polymer analysis App D 0766 Calibration Curves for GPC KF-800 Series Column: Dimensions: 0 7 GPC KF-800 series 8 x 00 mm App D 0768 Calibration Curves for GPC Mixed Bed Columns Column: Dimensions: 0 7 GPC KF-800L series and KF-806M 8 x 00 mm App D 559 Polystyrene Standards Column: GPC KF-80 Eluent: THF Detector: 5 nm Sample:. PS, %. PS, %. PS %. n-propylbenzene % 5. Benzene % Molecular Weight (Polystyrene) KF-80 KF-806 KF-80 KF-807 KF-805 KF-80.5 KF-80 KF-80 KF-806M Elution Volume Elution (ml) volume (ml) Molecular Weight (Polystyrene) KF-805L KF-80L KF-80L KF-806L KF-807L KF-806M Elution Volume Elution volume (ml) (ml) min App D 7 Phenol Resin Eluent: THF Detector: 5 nm Temperature: 0 C App D 55 PEEK Resin Column: GPC K-806M x Eluent: CHCl /Cl CHCOOH=90/0 Detector: R Sample: PEEK 0. %, 50 µl App D 55 Polyvinylpyrrolidone Column: GPC KD-806M x Eluent: 0.0 M LiBr /DMF Detector: R Temperature: C Sample: Polyvinylpyrrolidone 0.5 %, 50 µl LF-80 (linear column) KF-80L (mixed-bed column) 0 0 min min min Phenomenex

3 Organic GPC Columns (continued) App D 55 Polyamide (Nylon) Column: GPC HFP-806M x Eluent: 5 mm TFA-Na in HFP Detector: R Temperature: 0 C App D 55 mproved Resolution from Solvent Peak Column: Dimensions: Eluent: Flow Rate: Detector: Sample: GPC KF-806L + KF-800D 8 x 00 mm + 8 x 00 mm THF.0 ml/min 5 nm Polystyrene standards. MW,80,000. MW,000. MW 07,000. MW 6, MW, MW 0 (Propylbenzene) App D 555 Low Density Polyethylene Column: GPC UT-806M x, HT-806M x Eluent: 0. % BHT in o-dichlorobenzene Detector: R Temperature: 0 C Sample:. LDPE Polyamide6/ 5 6 Polyamide KF-806L min UT - 806M X min Polyamide6 Polyamide66 KF-806L+KF-800D UT - 806M X min min min ORDERNG NFORMATON Standard Columns Column Type / Part No.: THF Chloroform DMF D x Length (mm) Plate Number Exclusion Limit GPC KF-80 GPC K-80 GPC KD-80 8 x 00 >6,000.5 x 0 (KD-80,.5 x 0 ) GPC KF-80 GPC K-80 GPC KD-80 8 x 00 >6,000 5 x 0 GPC KF-80.5 GPC K-80.5 GPC KD x 00 >6,000 x 0 GPC KF-80 GPC KD-80 8 x 00 >6,000 7 x 0 GPC KF-80 GPC K-80 GPC KD-80 8 x 00 >6,000 x 0 5 GPC KF-805 GPC K-805 GPC KD x 00 >0,000 x 0 6 GPC KF-806 GPC K-806 GPC KD x 00 >0,000 ( x 0 7 ) GPC KF-807 GPC KD x 00 >5,000 ( x 0 8 ) Note: 80, 80, 805, 806 and 807 are available packed in HFP. Mixed bed columns are specially designed to have wide linear molecular weight ranges. These mixed bed columns are highly recommended for correcting non-linear sections of molecular weight calibration curves. Mixed Bed Columns Column Type / Part No.: THF Chloroform DMF HFP D x Length (mm) Plate Number Exclusion Limit GPC KF-80L GPC K-80L 8 x 00 >6,000 7 x 0 GPC KF-80L GPC K-80L 8 x 00 >6,000 x 0 5 GPC KF-805L GPC K-805L 8 x 00 >0,000 x 0 6 GPC K-806L 8 x 00 >0,000 ( x 0 7 ) GPC KF-806M GPC KD-806M GPC HFP-806M* 8 x 00 >,000 ( x 0 7 ) GPC KF-807L 8 x 00 > 5,000 ( x 0 8 ) * HFP-806M plate number is >8,000 and the effective molecular weight range is 0 ~0 7. Phenomenex

4 Organic GPC Columns (continued) ORDERNG NFORMATON High Temperature GPC Columns Column Type D x Length Exclusion Usable Toluene (mm) Limit Temperature ( C) Price GPC HT-80 8 x 00 7 x GPC HT-80 8 x 00 x GPC HT x 00 x GPC HT x 00 ( x 0 7 ) 00-0 Note: Exclusion Limits in parentheses,( ), are estimated values. Solvent-Peak Separation Columns* Column Type THF Chloroform D x Length (mm) Price GPC KF-800D GPC K-800D 8 x 00 *These columns make the elution of low-molecular weight components slower and can be used to separate them from a solvent peak or other troublesome peaks. Wide Linear Working Range D x Length Plate Exclusion Column (mm) Number Limit Price GPC LF-80 8 x 00 > 7,000 7 x 0 Downsized GPC Columns Column Type THF D x Length (mm) Particle Size (μm) Pore Size (Å) Plate Number Exclusion Limit (Polystyrene) Price GPC KF x 50 0 >7,000,500 GPC KF x >7,000 5,000 GPC KF x >7,000 0,000 GPC KF x >7,000 70,000 GPC KF x >6,000 00,000 GPC KF x >7,000,000,000 GPC KF x 50 0,000 >7,000 (0,000,000) GPC KF-606M 6.0 x 50 0 >8,000 (0,000,000) GPC KF x 50 8 >,000 >5,000 (00,000,000) GPC KF-G.6 x 0 8 Guard Column Notes: For all column types. Recommended flow rate: 0. to 0.6 ml/min; Max. usable flow rate: 0.8 ml/min; Max. usable temperature 5 C. μm Semi-micro GPC Columns Column Type D x Length (mm) Plate Number Exclusion Limit (Polystyrene) Price GPC KF-0 HQ.6 x 50 5,000,500 GPC KF-0 HQ.6 x 50 5,000 5,000 GPC KF-0.5 HQ.6 x 50 5,000 0,000 GPC KF-0 HQ.6 x 50 5,000 70,000 GPC KF-0 HQ.6 x 50 5,000 00,000 GPC KF-05L HQ.6 x 50 8,000,000,000 GPC KF-06L HQ.6 x 50 8,000 (0,000,000) GPC KF-G.6 x 0 Guard column Comparison Between KF-00 HQ Series (Semi-micro GPC) and KF-800 Series (Standard Type). The plate number has increased by.5 times or more. The consumption of eluent has decreased to less than one fourth KF-00 series columns are best suited to determine molecular weight distribution and analysis of low molecular weight materials in polymer. Based on a μm SDVB copolymer packing material, improvements over older GPC columns include higher resolution, less solvent usage, better detection limits, and assurance of linear calibration curves. Column: GPC (A) KF-0HQ (.6 x 50 mm) (B) KF-80 (8.0 x 00 mm) Eluent: THF Flow Rate: (A) 0. ml/min (B).0 ml/min Detector: 5 nm Temperature: 5 C njection volume: 5 µl KF-0 HQ vs. KF-80 App D 7 Phenomenex

5 GFC (Aqueous GPC) Columns has a wide variety of columns for GFC. Three types of GFC columns packed with different gel materials are available. Series Name Packing Material Applications OHpak SB-800HQ PHM gel Used for general purpose GFC of water-soluble polymers, proteins and enzymes SUGAR KS-800 Sulfonated PS gel Mono, di, tri, oligo and polysaccharides, starches and celluloses PROTEN KW-800 Porous silica gel GFC of proteins, glycoproteins and peptides App D 0769 Calibration Curves for OHpak SB-800HQ Series Column: OHpak SB-800HQ Eluent: Water 0 7 Sample:. P-800. P-00. P P P P P-0 8. P-5 9. P P-. Maltotriose. Maltose 0. Glucose Molecular Weight (Pullulan) SB-80HQ SB-80.5HQ SB-806HQ SB-805HQ SB-80HQ SB-80HQ 5 SB-806MHQ App D 557 Hyaluronic Acid Column: OHpak SB-805 HQ x (600 mm total length) Eluent: 0. M NaNO Detector: R Temperature: 0 C Sample: Hyaluronic Acid min Elution Volume (ml) min App D 077 Dietary Fiber Column: SUGAR KS-80 x (600 mm total length) Eluent: Water Flow Rate: 0. ml/min Detector: R Temperature: 80 C njection Volume: 0 µl Sample: Dietary Fiber. Glycerol ORDERNG NFORMATON Aqueous GPC Columns D x Length Plate Exclusion Column Type/Part No. (mm) Number Limit Price OHpak SB-80HQ 8 x 00 >0,000 x 0 OHpak SB-80.5HQ 8 x 00 >5,000 x 0 OHpak SB-80HQ 8 x 00 >5,000 x 0 5 OHpak SB-80HQ 8 x 00 >5,000 x 0 6 OHpak SB-805HQ 8 x 00 >0,000 x 0 6 OHpak SB-806HQ 8 x 00 >0,000 ( x 0 7 ) OHpak SB-806MHQ 8 x 00 >0,000 ( x 0 7 ) OHpak SB-807HQ 8 x 00 >,500 (5 x 0 8 ) SUGAR KS-80 (Na + ) 8 x 00 >5,000 x 0 SUGAR KS-80 (Na + ) 8 x 00 >5,000 x 0 SUGAR KS-80 (Na + ) 8 x 00 >5,000 5 x 0 SUGAR KS-80 (Na + ) 8 x 00 >5,000 x 0 5 SUGAR KS-805 (Na + ) 8 x 00 >8,000 5 x 0 6 SUGAR KS-806 (Na + ) 8 x 00 >8,000 (5 x 0 7 ) PROTEN KW x 00 >0,000 5 x 0 PROTEN KW-80 8 x 00 >0,000.5 x 0 5 PROTEN KW-80 8 x 00 >0,000 6 x 0 5 Note: Exclusion Limits in parentheses,( ), are estimated values. Calibration Standards ORDERNG NFORMATON Calibration Standards Standard Type/Part No. Material Content MW Range Applications Price STANDARD P-8 Pullulan 0. g x 8 grades 5, ,000 GFC (aqueous GPC) STANDARD SM-05 PS 0.5 g x 0 grades,00 -,000,000 GPC with THF, chloroform, toluene, etc. See p. for full line of Polymer Calibration Standards. Phenomenex

6 Columns for PROTENS and Nucleic Acids on-exchange Columns EC series columns are suited for the analysis of proteins and nucleic acids. AXpak WA-6 is suited for the analysis of nucleic acids. ORDERNG NFORMATON EC Series Columns D x Length Plate Column Type/Part No. (mm) Number Packing Material Functional Group Price EC QA-85 8 x 75 >,000 PHM gel Quaternary ammonium (strong anion) EC DEAE-85 8 x 75 >,000 PHM gel Diethylaminoethyl (weak anion) EC SP-85 8 x 75 >,000 PHM gel Sulfopropyl (strong cation) EC CM-85 8 x 75 >,000 PHM gel Carboxymethyl (weak cation) AXpak WA-6 6 x 50 >,500 PHM gel Diethylaminoethyl (weak anion) Affinity Columns D x Length Ligand Compound Capacity/ Column Type/Part No. (mm) Ligand Load/g Column Applications Price AFpak AAB-89 8 x 50 Aminobenzamidine 00 µmol Serine proteases AFpak AAF-89 8 x 50 Acriflavine 0 µmol ATP Na.8 mg RNA, DNA, vitamins AFpak AAM-89 8 x 50 5'AMP 0 µmol Lactic dehydrogenase.5 mg NAD, ATP enzymes AFpak AAV-89 8 x 50 Avidin 5 mg Biotin 8 µg Biotin derivatives AFpak ACA-89 8 x 50 Concanavalin A 5 mg Glycoproteins, polysaccharides AFpak ACB-89 8 x 50 Cibacron Blue 0 µmol BSA 0 mg Albumin, NAD dependent enzymes AFpak AHR-89 8 x 50 Heparin 5 mg Lysozyme mg Lipoproteins, blood coagulation factors AFpak ALC-89 8 x 50 LCA (Lentil lectin) 7 mg Glycoproteins, polysaccharides AFpak APA-89 8 x 50 Protein A 8 mg gg human 0 mg Human gg, immune complexes AFpak APG-89 8 x 50 Protein G 5 mg gg human 0 mg gg immune complex AFpak ARC-89 8 x 50 RCA- 0 mg Glycoproteins, polysaccharides AFpak AST-89 8 x 50 Soybean trypsin inhibitor 0 mg Trypsin-like proteases AFpak AWG-89 8 x 50 Wheat germ agglutinin mg Glycoproteins, polysaccharides Other Columns D x Length Plate Packing Functional Separation Column Type/Part No. (mm) Number Material Group Mode Applications Price HC PH-8 8 x 75 >,000 PHM gel Phenyl HC Proteins RSpak NN-6 6 x 50 >5,000 PHM gel P&A Cystine and cysteine Columns for Sugar Analysis Series Name SUGAR series SUGAR KS-80 Applications Effective separation is possible for sugars and sugar alcohols using mixed modes such as SEC, EX, LEC and P&A. Suited for the separation of mono, di and oligosaccharides by mixed mode such as SEC and LEC. Ordering nformation Sugar Columns Column Type/ D x Length Plate Exclusion Packing Counter Separation Part No. (mm) Number Limit Material on Mode Price SUGAR SH0 8 x 00 >5,000,000 S-DVB gel H + SEC + EX SUGAR SH8 8 x 00 >5,000 0,000 S-DVB gel H + SEC + EX SUGAR SC0 8 x 00 >,000,000 S-DVB gel Ca + SEC + LEC SUGAR SC8 8 x 00 >,000 0,000 S-DVB gel Ca + SEC + LEC SUGAR SP080 8 x 00 >0,000,000 S-DVB gel Pb + SEC + LEC SUGAR SC 6 x 50 >5,000 S-DVB gel Ca + P&A + LEC SUGAR SZ55 6 x 50 >5,000 S-DVB gel Zn + P&A + LEC SUGAR KS-80 8 x 00 >5,000,000 S-DVB gel Na + SEC + LEC Aside from the columns listed here, there are other columns that can be used for sugar separations. Disaccharides of similar molecular weight can be separated by NPC using RSpak DC-6. SUGAR KS-800 series and OHpak SB-800 HQ series can also be used for sugar separations by SEC. Phenomenex 5

7 Columns for Organic Acids KC-8 enables an effective organic acids separation using a mixed mode of EX, SEC and P&A. Organic acids also can be separated by RPC using RSpak DE-6. ORDERNG NFORMATON RSpak Column Type*/ D x Length Plate Packing Counter Part No. (mm) Number Material on Price RSpak KC-8 8 x 00 >5,000 S-DVB gel H+ *Note: RSpak KC-8 was formerly known as onpak KC-8. on Chromatography Columns Great alternative to Dionex onpac AS, ASA and AS columns High efficiency, general purpose C column mproved, high-speed separation of EPA Method 00 analytes Fluoride well-resolved from water dip Patent-pending gel eliminates overlap of carbonate system peak Anions Column: S-90 E Dimensions:.0 x 50 mm Eluent:.8 mm Na CO.7 mm NaHCO Flow Rate:.0 ml/min Sample: 0 µl. Fluoride mg/l 5. Nitrate 0 mg/l. Chloride mg/l 6. Phosphate 5 mg/l. Nitrite 5 mg/l 7. Sulfate 5 mg/l. Bromide 0 mg/l App D 75 offers an innovative C column for the suppressor method that improves both the separation speed and resolution of anions in most matrices. With high theoretical plates (>5000/m for Sulfate), the column easily and efficiently separates organic and inorganic anions such as EPA Method 00 analytes, acetate, formate, methacrylate and oxalate. High loading and exceptional resistance to loading combine with features such as improved separation of the fluoride peak from the water dip. The patent-pending PVA gel was also specifically engineered to optimize the elution behavior of the carbonate ion so as not to interfere with the quantitation of EPA Method 00 anions. App D 76 Organic Acids and norganic Anions Column: S-50 E Dimensions:.0 x 50 mm Eluent:. mm Na CO / NaHCO Flow Rate: 0.7 ml/min Sample: 0 µl. Fluoride mg/l 7. Bromide 0 mg/l. Acetate 0 mg/l 8. Nitrate 0 mg/l. Formate mg/l 9. Phosphate 5 mg/l. Methacrylate 0 mg/l 0. Sulfate 5 mg/l 5. Chloride mg/l. Oxalate 5 mg/l 6. Nitrite 5 mg/l ORDERNG NFORMATON C Columns Column Type/ D x Length Plate Packing Part No. (mm) Number Material Functional Group Applications Price C S-90 E.0 x 50 >5,000 (SO ) PVA Quaternary ammonium norganic anions and organic acids C S-90 G.6 x 0 (Guard) (General purpose) C S-50 E*.0 x 50 >,000 PVA Quaternary ammonium norganic anions and organic acids C -5A.6 x 00 >,000 PHM gel Quaternary ammonium norganic anions C Y-5.6 x 50 >,000 Cations (general purpose) C Y-G.6 x 0 (Guard) C YK-.6 x 5 >,500 Hydrophilic Polymer Carboxyl Simultaneous separation of monovalent Coated Silica and divalent cations C YK-G.6 x 0 (Guard) C YS-50.6 x 5 >5,500 PVA Cations, Alkylamines, Transition Metal ions C YS-G.6 x 0 (Guard) C T-5.6 x 50 >,000 S-DVB gel Sulfo (H + ) Transition metal ions (packed in PEEK column) C T-G.6 x 0 (Guard) *Use C S-90G guard. 6 Phenomenex

8 Polymer-BASED Reversed Phase Columns RSpak RP8 DS DE DM NN Applications 500 Å column well-suited for protein and peptide analysis. Suited for analysis of hydrophilic substances that cannot be retained by ODS columns, such as medicines and food additives. Suited for wide applications because its characteristics are similar to those of ODS columns. Suited for analysis of amino acids and polypeptides. Suited for analysis of complex samples that are composed of neutral and basic substances. Generally, neutral substances are separated by reversed phase mode, acid substances by ionexclusion mode and basic substances by reversed phase mode and ion-exchange mode. ORDERNG NFORMATON RSpak Column Type/Part No. Plate Number D x Length (mm) Price RSpak RP8-5 >,000.6 x 50 RSpak DS-6 >6, x 50 RSpak DE-6 >7, x 50 RSpak DE- >,000.6 x 50 RSpak DE-L >7,000.6 x 50 RSpak DE-G (DE-6P) (guard column).6 x 0 RSpak DM-6 >, x 50 RSpak DM-G (DM-6P) (guard column).6 x 0 RSpak DC-6 >5, x 50 RSpak NN-6 >5, x 50 App D 55 Catecholamines Column: RSpak DE-6 Dimensions: 6 x 50 mm Eluent: 0.05 M KH PO % H PO Flow Rate: 0.6 ml/min Detection: 5 nm Sample: Catecholamines 5 µl. Norepinephrine 0.0 %. Epinephrine 0.0 %. Dopamine 0.0 % App D 55 Water-Soluble Vitamins Column: RSpak DM-6 Dimensions: 6 x 50 mm Eluent: M Na HPO M KH PO + 7 % CH OH Flow Rate: 0.6 ml/min Detection: 5 nm Sample: 0.05 % each, µl. Vitamin C*. Vitamin B. Vitamin B6. Vitamin B 5. Vitamin B 6. Caffeine App D 555 Tryptic Digest of Myoglobin Column: RSpak RP8-5 Dimensions:.6 x 50 mm Eluent: A: % Acetonitrile in 0. % TFA B: 95 % Acetonitrile in 0. % TFA Gradient: Linear B 0 % to 50 %, 0 min Detection: 0 nm *Note that Vitamin C easily oxidizes in this mobile phase min min min Phenomenex 7

9 MSpak PK-A and A Polymer Based Cartridge Columns Ultrafast On-Line SPE and analysis columns for LC/MS or LC/UV by column switching. For direct injection and analysis of drugs from serum, plasma or other body fluids Unique polymer based cartridge system cartridge dimensions 0 x.0 mm D and 0 x.0 mm D Also for ultrafast on-line SPE for LC/MS/MS Ordering nformation MSpak Column Type/Part No. D x length (mm) Unit Price MSpak PK-A p x 0 /pk MSpak PK-A 5p x 0 5/pk MSpak PK-A p x 0 /pk MSpak HLD Holder ea CHRAL COLUMNS Wide range of applications Durable polymer matrix enables wide ph stability Chemically modified cyclodextrins improve enantioselectivity Cyclodextrin phases for the direct separation of enantiomers have become increasingly popular due to their wide applicability. Showa Denko has taken these useful phases a few steps further by modifying the cyclodextrins with carboxymethyl (CM) functionality and bonding them to a chemically and physically stable polymer backbone. Modification of the cyclodextrins improves enantioselectivity for many compounds compared to native cyclodextrins. Utilization of durable polymethacrylate polymer as the anchor for this stationary phase enables use of highly alkaline and acidic mobile phases, not possible with silica-based CD phases. Separation of enantiomers of amino acids and their derivatives, amino alcohols, carboxylic acids, amines, alcohols and others are routinely performed with these columns. Basic Structure of CD Bonded Phase Guard Columns Use of a guard column immediately before the analytical or preparative column is highly recommended to protect the packing materials in the analytical column from contaminants or readily adsorbable substances. The guard column should be replaced at regular intervals. ORDERNG NFORMATON Guard Columns Guard Column/ D x Length Associated Part No. (mm) Column Price GPC KF-G.6 x 0 KF-800 GPC KD-G.6 x 0 KD-800 GPC AT-G 8.0 x 50 AT-800S OHpak SB-G 6.0 x 50 SB-800 HQ OHpak SB-LG 8.0 x 50 SB-000 OHpak SB-807G 8.0 x 50 SB-807 HQ PROTEN KW-G 6.0 x 50 KW-800 SUGAR KS-G 6.0 x 50 KS-800 SUGAR SH-G 6.0 x 50 SH0 SUGAR SH-G 6.0 x 50 SH8 SUGAR SC-LG 6.0 x 50 SC0 SUGAR SC-LG 6.0 x 50 SC8 C S-90G.6 x 0 S-90E, S-50E C YK-G.6 x 0 YK- C Y-G.6 x 0 Y-5 C YS-G.6 x 0 YS-50 RSpak KC-G 6.0 x 50 KC-8 RSpak DE-G.6 x 0 DE-6 RSpak DM-G.6 x 0 DM-6 Comparison of Retention Behavior Between Modified and Unmodified CD Bonded Phases Bonded Phase Met - NA* POPA** α Rs α Rs CD CM-CD.... * Met-NA: Methionine -naphthylamide ** POPA: -Phenoxypropionic acid ORDERNG NFORMATON Chiral Columns Column Type/Part No. D x Length (mm) Ligand Price ORpak CDA-5 HQ.6 x 50 α-cyclodextrin derivatives ORpak CDB-5 HQ.6 x 50 β-cyclodextrin derivatives ORpak CDC-5 HQ.6 x 50 γ-cyclodextrin derivatives ORpak CDBS-5.6 x 50 β-cyclodextrin derivatives See p. 08 for additional chiral stationary phases. 8 Phenomenex

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Shodex. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Shodex. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS Catalogue 9 Hichrom Limited The Markham Centre, Station Road Theale, Reading, Berks, RG7 PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

Cation Exchange HPLC Columns

Cation Exchange HPLC Columns Cation Exchange HPLC Columns Hamilton offers seven polymeric packing materials for cation exchange separations. Type Recommended Application(s) PRP-X00 PRP-X00 PRP-X800 HC-0 HC-7 Ca + HC-7 H + HC-7 Pb

More information

PHENOGEL GPC/SEC COLUMNS

PHENOGEL GPC/SEC COLUMNS 5, 10, and 20 μm particle sizes Narrow bore (4.6 mm D) solvent-saver to preparative columns available Very good alternative to Polymer Labs PLgel and Waters Styragel, Ultrastyragel, Styragel HT, and Styragel

More information

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 25: CHROMATOGRAPHIC METHODS AND CAPILLARY ELECTROPHORESIS

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 25: CHROMATOGRAPHIC METHODS AND CAPILLARY ELECTROPHORESIS Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 25: CHROMATOGRAPHIC METHODS AND CAPILLARY ELECTROPHORESIS CHAPTER 25: Opener Aa CHAPTER 25: Opener Ab CHAPTER 25: Opener B 25-1 Ion-Exchange

More information

Packings for HPLC. Packings for HPLC

Packings for HPLC. Packings for HPLC Summary of packings for HPLC In analytical HPLC, packings with particle sizes of 3 to 10 µm are preferred. For preparative separation tasks, also particles with diameters larger than 10 µm are applied.

More information

Ion Chromatography. Anion Exchange. Chromatography Ion Exchange Theory. Dr. Shulamit Levin

Ion Chromatography. Anion Exchange. Chromatography Ion Exchange Theory. Dr. Shulamit Levin Ion Exchange Chromatography Chromatographic Process BA Mobile phase Stationary Phase A Shula Levin Bioforum B Distribution: K = C s/c m B shulal@zahav.net.il http://shulalc.co.il/ A Elution through the

More information

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax Packed by Phenomenex High efficiency Guaranteed quality Phenomenex columns packed with 7 μm materials offer the advantages of lower cost as well as lower operating backpressures, which result in long column

More information

Advantages of polymerbased. an alternative for ODS

Advantages of polymerbased. an alternative for ODS Advantages of polymerbased HPLC columns an alternative for ODS Yukiko Higai Shodex, 1 Content (1) Comparison between Silica and Polymer-based RP columns (2) Characteristics of Polymer RP columns - an example:

More information

Saccharides and Organic Acids

Saccharides and Organic Acids Saccharides and Organic Acids Contents Introduction... 2 Reducing Sugars... 2 HILIC The HILICpak and Ashipak Series... 3 Shodex HILIC Columns for Sugar Analysis... 7 Ligand Exchange Shodex SUGAR series...

More information

groups I and II cations, amines, divalent transition metals

groups I and II cations, amines, divalent transition metals IC Columns Introduction Alltech IC Column Specifications Column Composition ph Range Applications Anion Exchange Columns Allsep polymer-based anion ph 0 inorganic anions, weak and strong acid ions, exchanger,

More information

Phenogel. GPC/SEC Columns. Sample Elution. Technical Specifications 10 3 Å 10 6 Å

Phenogel. GPC/SEC Columns. Sample Elution. Technical Specifications 10 3 Å 10 6 Å phenogel Gpc/sec columns HPLC 5 and 10 μm particle sizes Narrow bore (4.6 mm ID) solvent-saver to preparative columns available Very good alternative to Polymer Labs PLgel and Waters Styragel, Ultrastyragel,

More information

Shodex TM ODP2 HP series columns

Shodex TM ODP2 HP series columns HPLC Columns Shodex TM ODP2 HP series columns Better retention of highly polar substances Technical notebook No. 6 Contents 1. Introduction 1-1. Specifications 1-2. Eluent Compatibility of ODP2 HP Series

More information

Optical Isomer Separation Columns and Packing Materials

Optical Isomer Separation Columns and Packing Materials 02 Optical Isomer Separation s and Packing Materials CHIRAL ART----------------------------------- 26~29 YMC CHIRAL NEA (R), (S)-----------------------30 YMC CHIRAL CD BR------------------------------31

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS SIELC Primesep Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)8 90 660 Fax: +44 (0)8 9 484 Email: sales@hichrom.co.uk

More information

Dionex IonPac AS28-Fast-4µm column

Dionex IonPac AS28-Fast-4µm column CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS-Fast-4µm Columns Product Specifications The Thermo Scientific Dionex IonPac AS-Fast-4µm column is a high-capacity, hydroxide-selective anionexchange column

More information

Column Selection for Size Exclusion Chromatography (SEC)

Column Selection for Size Exclusion Chromatography (SEC) Column Selection for Size Exclusion Chromatography (SEC) Application Solvent Column Page Biological macromolecules (proteins, peptides, nucleic acids, etc.) Buffer etc. KW-800 series KW400 series High

More information

Gel Permeation Chromatography Basics and Beyond eseminar March 13, Jean Lane Technical and Applications Support LSCA, Columns and Supplies

Gel Permeation Chromatography Basics and Beyond eseminar March 13, Jean Lane Technical and Applications Support LSCA, Columns and Supplies Gel Permeation Chromatography Basics and Beyond eseminar March 13, 2013 Jean Lane Technical and Applications Support LSCA, Columns and Supplies 1 Content Overview of GPC/SEC What is it? Why do we use it?

More information

Liquid Chromatography

Liquid Chromatography Liquid Chromatography 1. Introduction and Column Packing Material 2. Retention Mechanisms in Liquid Chromatography 3. Method Development 4. Column Preparation 5. General Instrumental aspects 6. Detectors

More information

4. Ion chromatography (IC) 4.1. Educational aims and objectives

4. Ion chromatography (IC) 4.1. Educational aims and objectives 4. Ion chromatography (IC) 4.1. Educational aims and objectives Principles of ion chromatography method and instrumentation. Methods for ionic compounds analysis including ion chromatography and its subtypes.

More information

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS Anion-Exchange Column Product Specifications The Thermo Scientific Dionex IonPac AS anion-exchange column is designed for the fast analysis of inorganic

More information

GFC separation of water-soluble polymers with TSKgel PW-type columns (2) using the PWXL series. Contents

GFC separation of water-soluble polymers with TSKgel PW-type columns (2) using the PWXL series. Contents No.038 GFC separation of water-soluble polymers with TSKgel PW-type columns (2) using the PWXL series Contents Page 1. Introduction 2. Calibration curves, theoretical plate numbers and separation range

More information

Method Development with ZirChrom's Ion Exchange Phases

Method Development with ZirChrom's Ion Exchange Phases For Peak Performance ZIRCHROM ION EXCHANGERS Phases for Sugars and Proteins Wide Range of Ion Exchange Selectivity No Shrinking or Swelling Use Any Organic Solvent Significantly Higher Efficiency than

More information

GFC Analysis of Water-Soluble Polymers with TSKgel PW-type Columns. Contents

GFC Analysis of Water-Soluble Polymers with TSKgel PW-type Columns. Contents No.035 GFC Analysis of Water-Soluble Polymers with TSKgel PW-type Columns Contents Page 1. Introduction 2. Separation ranges for each grade of TSKgel PW-type column 3. GFC apparatus for water-soluble systems

More information

LC and LC/MS Column Selection Flow Chart

LC and LC/MS Column Selection Flow Chart LC and LC/MS Column Selection Flow Chart To use the column selection diagram below, simply follow the path for your analyte and mobile phase. At the far right, follow your final column selection to the

More information

Analysis - HPLC A.136. Primesep 5 µm columns B.136

Analysis - HPLC A.136. Primesep 5 µm columns B.136 Primesep 5 µm columns Primesep columns feature double functionality of the bonding i.e : alkyl chain with anionic or cationic group, chelating group. This feature creates unique selectivities when using

More information

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography) Ch.28 HPLC 28.1 Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography) High Performance (Pressure) LC Glass column st.steel (high

More information

Protein & peptide Shodex TM columns

Protein & peptide Shodex TM columns HPLC Columns Protein & peptide Shodex TM columns Technical notebook No. 7 Contents. Introduction. Separation of Proteins and Peptides by HPLC. Separation modes -. Size exclusion chromatography --. Separation

More information

Too Polar for Reversed Phase What Do You Do?

Too Polar for Reversed Phase What Do You Do? Too Polar for Reversed Phase What Do You Do? June 20, 2013 Mark Powell Columns and Consumables Technical Support Page 1 C8 or C18 Doesn t Always Do the Job Typical reversed phase conditions involve water/buffer

More information

Sepax SRT -C, Zenix -C SEC Phases

Sepax SRT -C, Zenix -C SEC Phases Sepax SRT -C, Zenix -C SEC Phases Complimentary Phases to SRT for Derivatized Monoclonal Antibodies General Description Stationary Phase Structure SRT, Zenix, SRT-C and Zenix-C SEC phases developed based

More information

Cation Exchange HPLC Columns

Cation Exchange HPLC Columns Cation Exchange PRP-X00 Polymeric cation exchange packing for separation of inorganic cations and organic cations. Easily separate mono or divalent cations. ph stable from to. Use with organic solvent

More information

IC Columns Introduction

IC Columns Introduction IC Columns Introduction Alltech IC Column Specifications Column Composition ph Range Applications Anion Exchange Columns Allsep polymer-based anion ph 0 inorganic anions, weak and strong acid ions, exchanger,

More information

High Performance Liquid Chromatography

High Performance Liquid Chromatography Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN

More information

High Performance Liquid Chromatography

High Performance Liquid Chromatography Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 1 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN

More information

New Product Update. HPLC Columns

New Product Update. HPLC Columns New Product Update HPLC Columns ZORBAX MicroBore HPLC Columns ZORBAX Extend-C18 Columns ZORBAX Bonus-RP Columns Inertsil ODS-2 Cartridge Columns ZORBAX Carbohydrate Analysis Columns ZORBAX Eclipse dsdna

More information

Clearing the Confusion: GPC, SEC, GFC What, When, Why, and How?

Clearing the Confusion: GPC, SEC, GFC What, When, Why, and How? Clearing the Confusion: GPC, SEC, GFC What, When, Why, and How? Jean Lane Applications Engineer LC Columns & Consumables Technical Support January 19, 2017 What we will cover What - Clarification of the

More information

Open Column Chromatography, GC, TLC, and HPLC

Open Column Chromatography, GC, TLC, and HPLC Open Column Chromatography, GC, TLC, and HPLC Murphy, B. (2017). Introduction to Chromatography: Lecture 1. Lecture presented at PHAR 423 Lecture in UIC College of Pharmacy, Chicago. USES OF CHROMATOGRAPHY

More information

Anion Exchange HPLC Columns

Anion Exchange HPLC Columns Anion Exchange PRP-X00 Polymeric anion exchange packings for separation of inorganic and organic anions. Easily separate the eight common anions (fluoride through sulfate). Good separation of fluoride

More information

Chromatography. writing in color

Chromatography. writing in color Chromatography writing in color Outlines of Lecture Chromatographic analysis» Principles and theory.» Definition.» Mechanism.» Types of chromatography.» Uses of Chromatography. In 1906 Mikhail Tswett used

More information

Optimizing GPC Separations

Optimizing GPC Separations Optimizing GPC Separations Criteria for Solvent Selection True sample solubility (Polarity and Time dependant) Compatibility with columns Avoid non-size exclusion effects (eg adsorption by reverse phase

More information

ProPac WCX-10 Columns

ProPac WCX-10 Columns ProPac WCX-10 Columns Guidance for column use Tips to maximize column lifetime ProPac WCX-10 Column Tips and Tricks This guide provides essential information and invaluable guidelines for mobile phases,

More information

Sample Preparation TLC Plates

Sample Preparation TLC Plates TLC PLATES TLC Plates Economical separation method High sample throughput Pilot procedure for HPLC and flash chromatography Versatile range of ready-to-use layers Thin layer chromatography (TLC) is a simple,

More information

Gel Permeation Chromatography - GPC

Gel Permeation Chromatography - GPC Isolation and Separation Methods J. Poustka, VŠCHT Praha, ÚAPV 2014, http://web.vscht.cz/poustkaj Gel Permeation Chromatography - GPC Separation and clean-up method Group separation of compounds with similar

More information

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX Technical Note Agilent s SampliQ WAX provides Applications for strongly acidic, acidic and neutral compounds Excellent

More information

No.106. Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series. Contents. Page

No.106. Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series. Contents. Page No.106 Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series Contents Page 1. Introduction 2. Features 3. Basic characteristics 3-1. Pore characteristics 3-2. Sample injection volume

More information

Quick guide to selecting columns and standards for Gel Permeation Chromatography and Size Exclusion Chromatography SELECTION GUIDE

Quick guide to selecting columns and standards for Gel Permeation Chromatography and Size Exclusion Chromatography SELECTION GUIDE Quick guide to selecting columns and standards for Gel Permeation Chromatography and Size Exclusion Chromatography SELECTION GUIDE Introduction Gel permeation chromatography (GPC) and size exclusion chromatography

More information

TSKgel Size Exclusion Chromatography Columns

TSKgel Size Exclusion Chromatography Columns Silica-based for protein analysis: TSKgel SW mab TSKgel SW TSKgel SWXL TSKgel SuperSW Polymer-based for desalting: TSKgel BioAssist DS Columns Polymethacrylate-based for water-soluble polymers analysis:

More information

Guide to Choosing and Using Polymer Reversed Phase Columns!

Guide to Choosing and Using Polymer Reversed Phase Columns! Guide to Choosing and Using Polymer Reversed Phase Columns! Choosing the best RP Column to use: Silica is normally used as the packing material for HPLC columns for a number of reasons. It is very strong,

More information

1. Ion exchange chromatography

1. Ion exchange chromatography 1. Ion exchange chromatography Ion Exchange Chromatography Most popular method for the separation or purification of charged molecules. In cation exchange chromatography, positively charged molecules are

More information

HICHROM. Chromatography Columns and Supplies. SAMPLE PREPARATION Solid Phase Extraction - CHROMABOND. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. SAMPLE PREPARATION Solid Phase Extraction - CHROMABOND. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies SAMPLE PREPARATION Solid Phase Extraction - Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)8 930 3660 Fax: +44

More information

SPE Columns. Solid Phase Extraction. SPE Columns

SPE Columns. Solid Phase Extraction. SPE Columns SPE Columns Solid Phase Extraction Solid-phase extraction (SPE) is a separation process by which compounds that are dissolved or suspended in a liquid mixture are separated from other compounds in the

More information

columns IonPac AS22 Anion-Exchange Column

columns IonPac AS22 Anion-Exchange Column columns IonPac AS Anion-Exchange Column The IonPac AS is a carbonate based anion-exchange column designed for the determination of inorganic anions and low-molecular-weight organic acids including fluoride,

More information

TCI Chiral HPLC Column

TCI Chiral HPLC Column TCI Chiral HPLC Column ~ Helical Polymer New Chiral Stationary Phase ~ Tokyo Chemical Industry Co.,Ltd. 212 Tokyo Chemical Industry Co., Ltd. Features of TCI Chiral A unique new stationary phase Polymaleimide

More information

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents No. 089 SEPARATION REPORT Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS Table of Contents 1. Introduction 1 2. Column Specification 1 3. Features of Packing Materials

More information

SPE Introduction. general chromatography. solid phase extraction. How to Choose an SPE Product. Solid-Phase Processing Methods

SPE Introduction. general chromatography. solid phase extraction. How to Choose an SPE Product. Solid-Phase Processing Methods How to Choose an SPE Product 1. Characterize the Sample Factors such as the analyte s polarity relative to the matrix, the presence of charged functional groups, solubility, molecular weight, etc., determine

More information

SPE. Simply Efficient! Watchers bond Solid Phase Extraction by ISU. Ver

SPE. Simply Efficient! Watchers bond Solid Phase Extraction by ISU. Ver SPE Simply Efficient! Watchers bond Solid Phase Extraction by ISU Ver. 05-11 Solid Phase Extraction Basic principles of Solid Phase Extraction Solid phase extraction (SPE) is a powerful method for sample

More information

INSTALLATION INSTRUCTIONS and TROUBLESHOOTING GUIDE. for the OnGuard- CARTRIDGE

INSTALLATION INSTRUCTIONS and TROUBLESHOOTING GUIDE. for the OnGuard- CARTRIDGE INSTALLATION INSTRUCTIONS and TROUBLESHOOTING GUIDE for the OnGuard- CARTRIDGE (OnGuard-RP, P/N 039595) (OnGuard-H, P/N 039596) (OnGuard-P, P/N 039597) (OnGuard-Ag, P/N 039637) (OnGuard-A, P/N 042102)

More information

Thermo Scientific. Anion-Exchange Column

Thermo Scientific. Anion-Exchange Column CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS9-µm Anion-Exchange Column Product Specifications The Themo Scientific Dionex IonPac AS9-µm high-capacity, hydroxide-selective, anion-exchange column is

More information

Polymer analysis by GPC-SEC. Technical Note. Introduction

Polymer analysis by GPC-SEC. Technical Note. Introduction Polymer analysis by GPC-SEC Technical Note Introduction Gel Permeation Chromatography (GPC), also referred to as Size Exclusion Chromatography (SEC) is a mode of liquid chromatography in which the components

More information

columns IonPac AS17-C Anion Exchange Column

columns IonPac AS17-C Anion Exchange Column columns IonPac AS-C Anion Exchange Column The IonPac AS-C is a hydroxide-selective anion exchange column designed for fast gradient separation of inorganic anions. The key application for the AS-C column

More information

LIQUID CHROMATOGRAPHY

LIQUID CHROMATOGRAPHY LIQUID CHROMATOGRAPHY RECENT TECHNIQUES HPLC High Performance Liquid Chromatography RRLC Rapid Resolution Liquid Chromatography UPLC Ultra Performance Liquid Chromatography UHPLC Ultra High Pressure Liquid

More information

Method Development Kits

Method Development Kits Method Development Kits sales representative for ordering information or contact...77 Method Development Kits First column choice for Pharma Development USP L C Method Development Kits Maximize retention

More information

TSKgel Size Exclusion Chromatography Columns

TSKgel Size Exclusion Chromatography Columns Silica-based for protein analysis: TSKgel SW mab TSKgel SW TSKgel SWXL TSKgel SuperSW Polymer-based for desalting: TSKgel BioAssist DS Columns Polymethacrylate-based for water-soluble polymers analysis:

More information

GPC/SEC Practical Tips and Tricks. Thomas Dent Applications Scientist Agilent Technologies. October, 2011 Gulf Coast Conference

GPC/SEC Practical Tips and Tricks. Thomas Dent Applications Scientist Agilent Technologies. October, 2011 Gulf Coast Conference GPC/SEC Practical Tips and Tricks Thomas Dent Applications Scientist Agilent Technologies October, 2011 Gulf Coast Conference 1 Section 1: Introduction Goals Brief introduction to GPC/SEC Highlight considerations

More information

columns IonPac AS18 Anion-Exchange Columns

columns IonPac AS18 Anion-Exchange Columns columns IonPac AS Anion-Exchange Columns The IonPac AS is a hydroxideselective anion-exchange column designed for the determination of inorganic anions and low-molecularweight organic acids including fluoride,

More information

LC Columns with Liquid Separation Cell Technology

LC Columns with Liquid Separation Cell Technology Obelisc LC Columns with Liquid Separation Cell Technology Obelisc HPLC Columns - Liquid Separation Cell Technology Introduction Obelisc HPLC columns are the latest, innovative columns from SIELC Technologies,

More information

TECHNICAL NOTEBOOK No.1. GPC LF series columns. Linear calibration curves over a wide molecular weight range. TECHNICAL NOTEBOOK. No.

TECHNICAL NOTEBOOK No.1. GPC LF series columns. Linear calibration curves over a wide molecular weight range. TECHNICAL NOTEBOOK. No. TECNICAL NOTEBOOK No.1 GPC LF series columns Linear calibration curves over a wide molecular weight range. TECNICAL NOTEBOOK No.1 Contents 1. Introduction 1 2. Shodex GPC LF series 2.1. Specifications

More information

Chapter content. Reference

Chapter content. Reference Chapter 7 HPLC Instrumental Analysis Rezaul Karim Environmental Science and Technology Jessore University of Science and Technology Chapter content Liquid Chromatography (LC); Scope; Principles Instrumentation;

More information

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3 Cogent HPLC Columns Manufactured by Table of Contents QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3 C8 Bidentate C8 Extremely long

More information

Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS

Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS EAS 2005 Bingwen Yan 1, Clayton V. McNeff 1, Richard A. Henry 2, and David S. Bell 2 1 ZirChrom Separations, Inc., 617 Pierce Street, Anoka,

More information

How proteins separate on reverse-phase HPLC

How proteins separate on reverse-phase HPLC 1 Reverse Phase How proteins separate on reverse-phase HPLC RP chromatography separates proteins through the interaction of the hydrophobic foot of the protein with a nonpolar surface of the particle RP

More information

Products for GPC. Products for GPC. Size exclusion chromatography. Basic principles

Products for GPC. Products for GPC. Size exclusion chromatography. Basic principles Products for GPC Products for GPC Size exclusion chromatography Basic principles injection A B C retention time mobile phase B Size exclusion chromatography (SEC) is a liquid chromatographic separation

More information

Aqueous and polar GPC/SEC columns. Product guide

Aqueous and polar GPC/SEC columns. Product guide Aqueous and polar GPC/SEC columns Product guide Contents Agilent PL aquagel-oh SEC columns 3 PL aquagel-oh preparative SEC columns 8 Agilent PolarGel GPC columns 9 PolarGel-L 10 PolarGel-M 11 Agilent PL

More information

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules columns Acclaim Mixed-Mode WCX- for Separating Basic Molecules The Acclaim Mixed-Mode WCX- is a novel, high-efficiency, silica-based column specially designed for separating various basic analytes. This

More information

Chemistry Instrumental Analysis Lecture 28. Chem 4631

Chemistry Instrumental Analysis Lecture 28. Chem 4631 Chemistry 4631 Instrumental Analysis Lecture 28 High Performance Liquid Chromatography () Instrumentation Normal Phase Chromatography Normal Phase - a polar stationary phase with a less polar mobile phase.

More information

Size Exclusion Chromatography: Method Development

Size Exclusion Chromatography: Method Development Size Exclusion Chromatography: Method Development To develop a successful Size Exclusion Chromatography (SEC) method it is desired to find a column/solvent combination under which the follow conditions

More information

GPC/SEC standards. Product guide

GPC/SEC standards. Product guide GPC/SEC standards Product guide Contents Polymer standards for GPC/SEC 3 Agilent EasiVial 5 Agilent EasiCal 8 Polystyrene 9 Polymethylmethacrylate 11 Polyethylene glycol/oxide 12 Other polymer standards

More information

HPLC Column Material - Bulk Ware

HPLC Column Material - Bulk Ware HPLC Column Material - Bulk Ware Constantly growing demands on separation efficiency and availability of solid phase material for packing HPLC columns and column packing stations have motivated us to provide

More information

Biology 30 The Chemistry of Living Things

Biology 30 The Chemistry of Living Things Biology 30 The Chemistry of Living Things Hierarchy of organization: Chemistry: MATTER: Periodic Table: ELEMENT: Ex. oxygen, gold, copper, carbon COMPOUND: Ex. salt (NaCl), H 2 O ELEMENTS ESSENTIAL TO

More information

GPC/SEC Column Selection & Method Development

GPC/SEC Column Selection & Method Development GPC/SEC Column Selection & Method Development LIVE WEBCAST: Tuesday April 27, 2010 Topics Introduction to GPC/SEC Column Characteristics & Column Selection Additional Method Development Troubleshooting

More information

Chromatography. Intro basic terminology types Partition and Adsorption C Ion-Exchange C Gel Filtration (aka Exclusion or Molecular Sieve) C Affinity C

Chromatography. Intro basic terminology types Partition and Adsorption C Ion-Exchange C Gel Filtration (aka Exclusion or Molecular Sieve) C Affinity C Chromatography Intro basic terminology types Partition and Adsorption C Ion-Exchange C Gel Filtration (aka Exclusion or Molecular Sieve) C Affinity C Extremely varied and widely used methodology for separation

More information

https://www.chemicool.com/definition/chromatography.html

https://www.chemicool.com/definition/chromatography.html CHROMATOGRAPHY 1 Chromatography - a physical method of mixture separation in which the components to be separated are distributed between two phases, one of which is stationary (stationary phase) while

More information

anion-exchange column

anion-exchange column columnsionpac ASA Anion-Exchange Column The IonPac ASA is a carbonateselective anion-exchange column designed for the fast separation of inorganic anions, including fluoride, chlorite, bromate, chloride,

More information

Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components

Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components APPLICATION UPDATE 157 Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components Authors Sumate Pengpumkiat, Weerapong Worawirunwong,

More information

SEPARATIONS ESSENTIALS IN MODERN HPLC. 2University of Bucharest, Bucharest, Romania

SEPARATIONS ESSENTIALS IN MODERN HPLC. 2University of Bucharest, Bucharest, Romania ESSENTIALS IN MODERN HPLC SEPARATIONS Serban C. Moldoveanu1, Victor David2 'R.J. Reynolds Tobacco Co., Winston-Salem, NC, USA 2University of Bucharest, Bucharest, Romania ELSEVIER AMSTERDAM BOSTON HEIDELBERG

More information

HPLC COLUMNS WILEY-VCH. Theory, Technology, and Practice. Uwe D. Neue with a contribution from M. Zoubair El Fallah

HPLC COLUMNS WILEY-VCH. Theory, Technology, and Practice. Uwe D. Neue with a contribution from M. Zoubair El Fallah HPLC COLUMNS Theory, Technology, and Practice Uwe D. Neue with a contribution from M. Zoubair El Fallah WILEY-VCH New York Chichester Weinheim Brisbane Singapore Toronto CONTENTS Preface ix 1 Introduction

More information

TSKgel SW TSKgel SW XL TSKgel SuperSW. TSKgel PW TSKgel PW XL -CP. TSKgel Alpha TSKgel SuperAW. TSKgel H XL TSKgel H HR TSKgel Super H TSKgel Super HZ

TSKgel SW TSKgel SW XL TSKgel SuperSW. TSKgel PW TSKgel PW XL -CP. TSKgel Alpha TSKgel SuperAW. TSKgel H XL TSKgel H HR TSKgel Super H TSKgel Super HZ 8 www.tosohbioscience.com size exclusion CHROMATOGRAPHY Tosoh bioscience ANALYSIS sec size exclusion chromatography 9 size exclusion CHROMATOGRAPHY PRODUCTS TSK-GEL SW-type TSKgel SW TSKgel SW XL TSKgel

More information

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS penta-hilic UHPLC COLUMNS penta-hilic Highly retentive, proprietary penta-hydroxy-ligand Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and

More information

for Acclaim Mixed-Mode HILIC-1 Column

for Acclaim Mixed-Mode HILIC-1 Column for Acclaim Mixed-Mode HILIC-1 Column Product Manual for ACCLAIM Mixed-Mode HILIC-1 Page 1 of 17 Product Manual for ACCLAIM Mixed-Mode HILIC-1 Column 5µm, 4.6 x 250mm, P/N 066844 5µm, 4.6 x 150mm, P/N

More information

Comparison of different aqueous mobile phase HPLC techniques

Comparison of different aqueous mobile phase HPLC techniques June 009 ewsletter Pharmaceutical Analysis: What is Your Problem? SIELC Technologies, Inc., Prospect Heights, IL 0070 Pharmaceutical analysis involves liquid chromatography of various compounds, from active

More information

Abstract: An minimalist overview of chromatography for the person who would conduct chromatographic experiments, but not design experiments.

Abstract: An minimalist overview of chromatography for the person who would conduct chromatographic experiments, but not design experiments. Chromatography Primer Abstract: An minimalist overview of chromatography for the person who would conduct chromatographic experiments, but not design experiments. At its heart, chromatography is a technique

More information

GPC/SEC An essential tool for polymer analysis

GPC/SEC An essential tool for polymer analysis GPC/SEC An essential tool for polymer analysis Ben MacCreath, PhD Product Manager GPC/SEC Instrumentation 26 th March 2013 Introduction to Polymers Where are they found? Polyolefins Engineering Polymers

More information

Optimisil HPLC & UPLC Column catalogue

Optimisil HPLC & UPLC Column catalogue Optimisil HPLC & UPLC Column catalogue Analytical Hub Plot No: 37, P & T Colony, Vikrampuri, Secunderabad 500009 Tel: 040-64621313, Mobile: +91 7799931313 Website: www.analyticalhub.com email: contact@analyticalhub.com

More information

Thermo Scientific Dionex IonPac AS23 Anion-Exchange Column

Thermo Scientific Dionex IonPac AS23 Anion-Exchange Column Chromatography Thermo Scientific Dionex IonPac AS Anion-Exchange Column Product Specifications The Thermo Scientific Dionex IonPac AS high-capacity, carbonate based anion-exchange column is designed for

More information

High Performance Liquid Chromatography

High Performance Liquid Chromatography High Performance Liquid Chromatography What is HPLC? It is a separation technique that involves: Injection of small volume of liquid sample Into a tube packed with a tiny particles (stationary phase).

More information

Cellufine Butyl Cellufine Phenyl

Cellufine Butyl Cellufine Phenyl Hydrophobic Interaction Chromatography Media Cellufine Butyl Cellufine Phenyl Technical Data Sheet Introduction For purification of proteins and macromolecules Hydrophobic Interaction Chromatography (HIC)

More information

6 Optical Isomer Separation Columns

6 Optical Isomer Separation Columns YMC GENERAL CATALG ptical Isomer Separation Columns YMC CHIRAL CD BR series YMC CHIRAL NEA YMC CHIRAL PREP CD ST/PM 128,129 13,131 132,133 127 第 章.indd 127 11.1.28 1:57:24 AM ptical isomer structural isomer

More information

Thermo Scientific Dionex IonPac AS25 Anion-Exchange Column. Minutes

Thermo Scientific Dionex IonPac AS25 Anion-Exchange Column. Minutes columns Thermo Scientific Dionex IonPac AS Anion-Exchange Column Isocratic Separation of Sulfur Species and Inorganic Anions Using the Dionex IonPac AS Column. Fluoride. Bromate. Chloride. Nitrite. Bromide.

More information

SRT -10/10C (10 µm ) Fast Protein Purification For FPLC, HPLC and Prep LC. Sepax Technologies, Inc. Preparative Size Exclusion Chromatography

SRT -10/10C (10 µm ) Fast Protein Purification For FPLC, HPLC and Prep LC. Sepax Technologies, Inc. Preparative Size Exclusion Chromatography Sepax Technologies, Inc. Preparative Size Exclusion Chromatography SRT -0/0C (0 µm ) Fast Protein Purification For FPLC, HPLC and Prep LC Better Surface Chemistry for Better Separation SRT -0/0C Size Exclusion

More information

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography Application Note Inorganic Ions, Water Testing, Minerals, Metals, Basic Chemicals Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography Authors Anne Mack, Adam Bivens

More information

HPLC Columns and Accessories. Solutions for liquid chromatography

HPLC Columns and Accessories. Solutions for liquid chromatography HPLC Columns and Accessories Solutions for liquid chromatography Innovation and excellence in chromatography Hamilton Company has been developing and manufacturing pressure-stable polymeric high performance

More information