Water terminal control solutions

Size: px
Start display at page:

Download "Water terminal control solutions"

Transcription

1 Water Terminal Control Solutions Water terminal control solutions Carrier offers a wide range of fan coil units designed to meet the needs of different systems and applications: from cabinet units in the room, through cassettes and a variety of ducted units that allow remote installation. The benefits and advantages of the different offers are described in the Hydronic Fan Coil Solutions brochure. To complement the different fan coil solutions, Carrier offers a range of electronic controllers, developed and tested to ensure correct management of hydronic terminal fan coil units and to deliver maximum satisfaction to the user. These controllers are available for all system configurations including: 2-pipe, 2-pipe changeover, 2-pipe + electric heater and 4- pipe applications. A selection of fan coil controllers is available, designed to offer the best solution for each installation, with the performance features required by the customer. Features Stand-alone electronic thermostats offer a costeffective solution that does not compromise on features and includes enhancements such as an energy-saving option (eco mode). Grouped and remote control needs are met with the HDB controller. This is factory-installed in the units, making installation easy. Only the power supply and the user interface connections for the wall-mounted or infrared remote control need to be field-connected. Where grouping of the fan coil units is required by the application, the simple addition of an optional communication board and the corresponding daisychain bus wiring will provide this functionality. The communicating control system offer includes the new NTC communicating controller. This advanced controller can integrated into the Carrier Aquasmart Evolution hydronic system range or into any Carrier system using the Carrier Comfort Network (CCN) protocol. Depending on the application needs, this controller offers a broad range of user interfaces, and advanced functionalities such as variable-speed fan control or Demand Control Ventilation. Whatever the customer requirements, Carrier offers a solution.

2 M s T h e r m o s t a t s H D B N T C A q u a s m a r t C o n t r o l a l g o r it h m O n o f f x x P r o p o r t i o n a l i n t e g r a l x x V a lv e m a n a g e m e n t A i r f l o w c o n t r o l o n ly ( n o v a lv e ) x x x O n o f f a c t u a t o r s x x x P r o p o r t i o n a l v a lv e s o F a n c o n t r o l T h r e e s p e e d s x x x x O p t i m u m f a n s p e e d s e l e c t i o n x x x x V a r i a b l e s p e e d o a i n f u n c t i o n s S e t p o i n t c o n t r o l x x x x O c c u p i e d / u n o c c u p i e d m o d e x x x x F r o s t p r o t e c t i o n m o d e x x x x W i n d o w c o n t a c t i n p u t x x x x M e a s u r e m e n t o f w a t e r i n l e t t e m p e r a t u r e f o r a u t o m a t i c s e a s o n a l c h a n g e o v e r ( 2 p i p e s ) T y p e A x x x A u t o m a t i c s e a s o n a l c h a n g e o v e r ( 4 p i p e s a n d 2 p i p e s + e l e c t r i c h e a t e r ) T y p e B x x x M a n u a l c h a n g e o v e r x x x x F r o s t p r o t e c t i o n m o d e x x x x C o n t i n u o u s v e n t i l a t i o n w h i n d e a d b a n d x x x x P e r i o d i c a l v e n t i l a t i o n w h i n d e a d b a n d x x x x U n g r o u p i n g x x x L o u v r e c o n t r o l x x x O n s e c o n f i g u r a t i o n x x x S u p p a i r t e m p e r a t u r e m o n o r i n g l i m i n g x x C o m m u n i c a t i o n ( C C N ) x x E l e c t r i c a l h e a t e r l o a d s h e d x x D i r t y f i e r a l a r m x x A l a r m r e p o r t i n g x x I A Q c o n t r o l o D e m a n d c o n t r o l v e n t i l a t i o n ( D C V ) o F r e e c o o l i n g m o d e o it it it it ly it it lt U s e r i n t e r f a c e D i g it a l d i s p l a y x x x A u t o m a t i c o r m a n u a l f a n s p e e d c o n t r o l x x x x O p e r a t i n g m o d e s e l e c t i o n x x x x O c c u p a n c y ( e c o ) b u t t o n x x x x S y s t e m m a n a g e m e n t M a n a g e m e n t o f z o n e s x S e t p o i n t m a n a g e m e n t a c c o r d i n g t o o c c u p a n c y x M a n a g e m e n t o f s y s t e m h e a t i n g / c o o l i n g m o d e a c c o r d i n g t o b u i l d i n g d e m a n d x S c h e d u l i n g o f s y s t e m o p e r a t i o n p e r z o n e x C e n t r a l i s e d m a n a g e m e n t o f o p e r a t i n g p a r a m e t e r s, a l a r m s a n d m a i n t e n a n c e x o = a v a i l a b l e a s a n o p t i o n

3 F e a t u r e s Fan operation With the fan speed selector, fan mode can be set either manually or automatically. In the manual mode it is possible to select three fan speeds (low/medium/high) according to personal preference. In the auto mode fan speed is regulated by a microprocessor in the control, based to the temperature chosen. Temperature selector This is designed to maintain the temperature at the desired level. The reference value at the centre of the range is 20 C. By turning the knob towards the symbol (-) the temperature is reduced from the original setting (minimum value is 10 C). By turning the knob towards the symbol (+), the temperature is raised from the original setting (maximum value is 30 C). Energy saving mode This function is especially useful when air conditioning at night or in rooms where the user is likely to be absent for a longer period of time. In this case, pushing the button raises the temperature during cooling by 4 C and lowers it during heating by 4 C. Frost-protection This function keeps the temperature from dropping below 7 C in rooms not used for long periods of time. Seasonal changeover - Manual: Selection of heating/cooling is done manually by pushing the button on the control. - Centralised (only for type A control): Centralised seasonal changeover is possible in two ways: - by a switch located on the central control panel that allows heating/cooling mode changeover (to be provided by the installer). - by a temperature sensor located in contact with the entering water pipe - Automatic, based on air temperature (only for type B control): The automatic seasonal changeover allows automatic switching of the fan coil operating mode to cooling or heating, depending on the temperature set by the user and on the room temperature. External contact The control has a 230 V input that can be used as window contact or presence detector. When such a signal is activated (presence of line voltage on the terminal block contact) the control is set to OFF mode. As a consequence, all outputs (fan, valves etc.) are disconnected, and only frost protection is active, if switched ON by the appropriate dip-switch. The Carrier electronic thermostats are designed to control and optimise the operation of hydronic terminal fan coil units. They exist in two versions (types A and B) that match all terminal fan coil configurations. T y p e A T y p e B 2 J p i p e x 2 J p i p e c h a n g e o v e r x 2 J p i p e a n d e l e c t r i c h e a t e r x 2 J p i p e c h a n g e o v e r a n d e l e c t r i c h e a t e r x 4 J p i p e x

4 F e a t u r e s The HBD controller is a microprocessor-based controller designed to control and optimise the operation of hydronic terminal fan coil units. Factory-installed on the terminal fan coil The controller is factory-installed on the terminal fan coil; the assembly is also tested at the factory. As a result, field installation is extremely simple. User interfaces Depending on the application, two user interface types can be selected: - a wired user interface that can be mounted on the wall or inside compatible terminal fan coils (42N) - an infrared user interface to be used together with a wall-mounted infrared received or a receiver incorporated in compatible terminal fan coils (42GW) Ease of grouping As an option, the HDB control can be equipped with a grouping board that is used to connect up to 15 units with a bus. All units connected together will operate under the same conditions. Louvre control For terminal fan coils equipped with motorised louvres, the HDB controls the louvre position as defined by the user or in swing mode. External contact The control has an input that can be used to remotely set the unit to economy mode. Scheduling If the unit is used with an infrared user interface, unit operation time can be scheduled on a daily basis. Three start times and three stop times can be programmed. Timer If the unit is used with an infrared user interface it can operate for a predefined duration before switching to eco mode or off

5 A B A B F e a t u r e s The NTC controller is a microprocessor-based, CCN (Carrier Comfort Network) compatible communicating controller designed to control and optimise the operation of hydronic terminal fan coil units. The controller can function as either a standalone control or as part of the CCN. Factory-installed on terminal fan coils The HDB controller is factory-installed on the terminal fan coil; the assembly is also factory-tested. As a result, field installation is extremely simple. User interfaces Depending on the application, two user interface types can be selected: - a simplified wired user interface (SUI) that can be wall-mounted - a wired user interface (CRC2) that can be wallmounted or incorporated in compatible terminal fan coils (42N) - an infrared user interface (IR2) for use together with a wall-mounted infrared received or a receiver incorporated on compatible terminal fan coils (42GW) - a multifunction user interface (ZUI) that can control comfort, lights and blinds within a Carrier system Network communication The NTC communicating controller can be connected on an RS 485 bus, using the Carrier Comfort Network (CCN) protocol. Units equipped with the NTC communicating controller can be part of the Aquasmart Evolution system. In addition, the NTC communicating controller can offer the following functions as options (not available within Aquasmart Evolution environment): - Variable speed management: The NTC controller can drive the speed of the fan continuously within a configurable range for optimal thermal and acoustic comfort. - Demand controller ventilation (DCV): On fan coils equipped with CO 2 sensors and fresh air dampers, the NTC controller can adjust the amount of fresh air admitted to the room, as required by the occupants - IAQ management: The NTC controller can control all features related to Indoor Air Quality that are included in Carrier terminal fan coil units b a 5 6 L e g e n d 1 N T C c o n t r o l l e r 2 S e c o n d a r y c o m m u n i c a t i o n b u s 3 U s e r i n t e r f a c e c o n n e c t i o n 4 I R 2 5 Z U I 2 6 C R C 2 L o c a l A L o c a l B

6 p A B F e a t u r e s Aquasmart Evolution is a complete HVAC system especially suited for residential and light commercial office buildings, hotels and hospitals. Aquasmart ensures perfect comfort for the building occupants. It allows both individual control, based on comfort parameters and central control to ensure optimisation of energy consumption. The Aquasmart System Manager is connected to the system components via a communication bus, and controls all air conditioning operating parameters. By coordinating the control intelligence in each component and by assembling all data at a single point, Aquasmart Evolution optimises energy consumption, monitors component operation and continually reports any system faults. The system can be composed of up to 128 terminal fan coil units that can be organised in 32 zones. Heating and cooling is coordinated by the System Manager for maximum comfort and optimal energy consumption. Occupied/unoccupied time schedules can be programmed, and the system includes smart start features to ensure that comfort requirements will be met from the very beginning of the occupied period. System configuration is simple through easily accessible menus. Unit grouping is managed by the network and requires no specific wiring. This means the system can be easily reconfigured to suit later modifications to the occupied area. The Aquasmart Evolution components are delivered complete, configured and factory-tested. H e a t p u m P r i m a r y b u s S y s t e m M a n a g e r S e c o n d a r y b u s L e g e n d 1 N T C c o n t r o l l e r 2 S e c o n d a r y c o m m u n i c a t i o n b u s 3 U s e r i n t e r f a c e c o n n e c t i o n 4 I R 2 5 Z U I 2 6 S U I 7 C R C 2 L o c a l A L o c a l B a b

7

8 M a n u f a c t u r e d b y : C a r r i e r S C S, M o n t l u e l, F r a n c e. O r d e r N o ê 2 0, S u p e r s e d e s o r d e r N o. : N e w. P r i n t e d o n T o t a l ly C h l o r i n e F r e e P a p e r. M a n u f a c t u r e r r e s e r v e s t h e r i g h t t o c h a n g e a n y p r o d u c t s p e c if i c a t i o n s w it h o u t n o t i c e. P r i n t e d i n t h e N e t h e r l a n d s.

XHDU Cassette type fan-coils for double/four pipe connections 1,98-14 kw HYDRONIC TERMINALS

XHDU Cassette type fan-coils for double/four pipe connections 1,98-14 kw HYDRONIC TERMINALS HYDRONIC TERMINALS XHDU 402 1203 Versions XHDU 2T XHDU-R 2T XHDU 4T XHDE 2T Single coil for double pipe connections Single coil for double pipe connections with heater Double coil for four pipe connections

More information

ClimateMaster s Tranquility 22. Raj Hiremath Director of Residential Marketing

ClimateMaster s Tranquility 22. Raj Hiremath Director of Residential Marketing ClimateMaster s Tranquility 22 Raj Hiremath Director of Residential Marketing 1 CLIMATEMASTER Industry leader since 1950 s First to introduce 2-stage 27 EER unit First to introduce Outdoor split system

More information

SYSTEM OF ELECTRONIC PUMPS IN CASCADE Heating Air conditioning 50 Hz

SYSTEM OF ELECTRONIC PUMPS IN CASCADE Heating Air conditioning 50 Hz RANGE OF USE Flow rate: from 0 to 0 m/h Manometric head: up to mce Temperature of the fluid: from 0 to + C Ambient temperature: -0 to +0 C Max. operating pressure: bars (version SIE) bars (version LRE)

More information

SVH with HYDROVAR (HVL range)

SVH with HYDROVAR (HVL range) SVH with HYDROVAR (HVL range) SVH-HVL Rev. B Ed.9/1 (EN) SVH SERIES (e-sv WITH HYDROVAR) Background and context For all pumping needs in commercial or residential building and in industry applications,

More information

Singer. Incremental Comfort Systems. K, EK Vintage F. Last Manufactured: Replacement Parts List No Revision C 04/2012

Singer. Incremental Comfort Systems. K, EK Vintage F. Last Manufactured: Replacement Parts List No Revision C 04/2012 Replacement Parts List No. 055231000 Revision C 04/2012 Singer Incremental Comfort Systems K, EK 07-15 Vintage F Last Manufactured: 1976 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Installation Operation Commissioning Maintenance

Installation Operation Commissioning Maintenance NA 09.13 H 09-2011 Microchip and LCD display electronic regulation and signaling electronic module for liquid coolers and heat pumps Installation Operation Commissioning Maintenance 1 CONTENTS 1 IMPORTANT

More information

TEC BACnet MS/TP Network Series Thermostat Controllers Technical Bulletin

TEC BACnet MS/TP Network Series Thermostat Controllers Technical Bulletin TEC BACnet MS/TP Network Series Thermostat Controllers Technical Bulletin Code No. LIT-12011592 Issued June 22, 2010 Supersedes December 1, 2009 Introduction..........................................................

More information

Offi ces account for more than 30% of total commercial building energy use

Offi ces account for more than 30% of total commercial building energy use S o l u t i o n s f o r o f fi c e b u i l d i n g s Offi ces account for more than 30% of total commercial building energy use At Schneider Electric, we deliver energy management expertise that can help

More information

6-way valve with room temperature controller. Balanced climate control. World premiere! e. Cost and energy economies

6-way valve with room temperature controller. Balanced climate control. World premiere! e. Cost and energy economies 6-way valve with room temperature controller. Balanced climate control. We set standards. www.belimo.eu World premiere! e Virtuoso performance to raise comfort and cut costs. Sustainable well-being hinges

More information

Variable swirl diffusers

Variable swirl diffusers Swirl diffusers, Variable swirl diffuser OD- Application Diffuser is designed for air conditioning of rooms with floor to ceiling highs of to 0 m and high induction requirements. It is suitable for large

More information

Swegon CASA Smart ModBus Register SCB 3.0

Swegon CASA Smart ModBus Register SCB 3.0 USER SETTINGS 3.0-> 4x5001 RW Operating Mode 0 4 0= Stopped, 1 = Away, 2 = Home, 3 = Boost, 4 = Travelling 3.0-> 4x5019 RW Smart Control -100 100 % Smart control Increase or decrease Ventilation level

More information

technical bulletin Installation Instructions: Wall-Mount Dewpoint Probe ( )

technical bulletin Installation Instructions: Wall-Mount Dewpoint Probe ( ) Installation Instructions: Wall-Mount Dewpoint Probe (809-2011) The HMW90 Wall-Mount Dewpoint Probe (P/N 809-2011) HMW90 measures dewpoint for indoor applications such as anti-sweat heater control and

More information

THE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP

THE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP I N V E RT E R ion Range exible Combine Modular TDV I TDV I TDV I INVERTER INVERTER INVERTER 14, 16, 18, 20, 22 HP TDV I 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP INVERTER INVERTER INVERTER TDV I INVERTER

More information

CALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05

CALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05 Modulating digital controller for heating and cooling series REGI ERED SI EN ISO 00:000 Cert. n FM UNI EN ISO 00:000 Cert. n 000 0/0 G replaces dp 0/0 Function The controller can be used with three-point

More information

Reference 1 Thermal Energy Metering. Abstract: Some aspects of the selection and installation requirements for thermal energy metering are canvassed.

Reference 1 Thermal Energy Metering. Abstract: Some aspects of the selection and installation requirements for thermal energy metering are canvassed. Reference 1 Thermal Energy Metering Project Reference: Metering_Thermal Industry or sector: All Energy use: All Date added: Sep 2011 Thermal Energy Metering Abstract: Some aspects of the selection and

More information

BERMAD Irrigation. BIC2000 Weather Station SYSTEM GUIDE VERSIONS : BIC ; PC 4.90

BERMAD Irrigation. BIC2000 Weather Station SYSTEM GUIDE VERSIONS : BIC ; PC 4.90 BIC2000 Weather Station SYSTEM GUIDE VERSIONS : BIC2000 3.92; PC 4.90 CONTENTS 1. SYSTEM OVERVIEW 3 2. WEATHER STATION SETUP 4 2.1 ISS AND CONSOLE SETUP 4 2. RF RTU SYSTEM SETUP 5 2.2 BIC2000 WEATHER STATION

More information

Panel Mount, Single Phase 120 and 240 Volt Fixed Shaft (click blue text for more details)

Panel Mount, Single Phase 120 and 240 Volt Fixed Shaft (click blue text for more details) Staco Energy Products Co. has been a leading manufacturer of variable transformers for over 60 years, building standard as well as custom-designed products for industrial, commercial and military applications.

More information

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS Variable or constant flow regulation or constant pressure regulation Wireless communication via radio Integrated sensor

More information

PATENT PENDING. Easy Gripper product range. #94060 Easy Gripper #94095 Easy Gripper Compact Accessories. Improve SAFETY and efficiency

PATENT PENDING. Easy Gripper product range. #94060 Easy Gripper #94095 Easy Gripper Compact Accessories. Improve SAFETY and efficiency PATENT PENDING By Easy Gripper product range #94060 Easy Gripper #94095 Easy Gripper Compact Accessories Improve SAFETY and efficiency STANDARD OPTIONAL Your Easy Gripper Contact us to find out which Easy

More information

VK2 volume flow controller Overview

VK2 volume flow controller Overview New option with sound attenuator Maintenance-free VK2 volume flow controller that operates without an auxiliary power supply, for ventilation and air conditioning systems. Adjustable on site. Outstanding

More information

Lightcloud Application

Lightcloud Application Controlling Your Lightcloud System Lightcloud Application Lightcloud Application Navigating the Application Devices Device Settings Organize Control Energy Scenes Schedules Demand Response Power Up State

More information

VRF Technical Data Book

VRF Technical Data Book VRF Technical Data Book DVM S for Euro_ET (R4A, Hz, HP) Model : Premium (Compact / Energy Efficiency) Type Standard Type History Version Modification Date Remark Ver. 1. Release DVM S (R4A, Hz, HP) for

More information

Rectangular air volume controller RWPA

Rectangular air volume controller RWPA Rectangular air volume controller RWPA TECHNICAL DATA - 2012 page 189 Rectangular air volume controller RWPA Rectangular air volume controller RWPA enables automatic airflow control. RWPA is suitable for

More information

Intuitive air velocity and IAQ.

Intuitive air velocity and IAQ. Intuitive air velocity and IAQ. The new combines versatility and maximum convenience. 1 The new air velocity & IAQ measuring instrument: versatility in a compact format. Welcome to a new era: the new combines

More information

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components: SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine

More information

Aircon Energy Saver Evaluation Report for SHUI ON DEVELOPMENTS ...

Aircon Energy Saver Evaluation Report for SHUI ON DEVELOPMENTS ... . Aircon Energy Saver Evaluation Report for SHUI ON DEVELOPMENTS.......... Report for the testing of the Aircon Energy Saver when installed on DX cooling equipment at Rainbow City, Shanghai, China Test

More information

variable flow dampers

variable flow dampers Constant-/ DAU, DAEU, DAVU Summary DAU - manual single flow unit DAEU - motorized twin flow unit DAVU - motorized variable flow unit Diameters Ø 0 Flow range 0 l/s ( m³/h) Pressure range Pa (over the unit)

More information

TALLINN UNIVERSITY OF TECHNOLOGY, INSTITUTE OF PHYSICS 6. THE TEMPERATURE DEPENDANCE OF RESISTANCE

TALLINN UNIVERSITY OF TECHNOLOGY, INSTITUTE OF PHYSICS 6. THE TEMPERATURE DEPENDANCE OF RESISTANCE 6. THE TEMPERATURE DEPENDANCE OF RESISTANCE 1. Objective Determining temperature coefficient of metal and activation energy of self-conductance of semiconductor sample. 2. Equipment needed Metal and semiconductor

More information

MODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH

MODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH MODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH No. Part Name Quantity BOM code List Price Remark 1 Panel assembly 1 201132890609 2 Air filter 2 201132890704 5 Display box

More information

QNET Experiment #05: HVAC System Identification. Heating, Ventilation, and Air Conditioning Trainer (HVACT) Student Manual

QNET Experiment #05: HVAC System Identification. Heating, Ventilation, and Air Conditioning Trainer (HVACT) Student Manual Quanser NI-ELVIS Trainer (QNET) Series: QNET Experiment #05: HVAC System Identification Heating, Ventilation, and Air Conditioning Trainer (HVACT) Student Manual Table of Contents 1. Laboratory Objectives...1

More information

PHASED OUT. FL ballasts Electronic dimming. PCA TC BASIC Y II, W BASIC compact

PHASED OUT. FL ballasts Electronic dimming. PCA TC BASIC Y II, W BASIC compact EL Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A BAT Noise-free precise control via DSI signal, switchdim or corridorfunction Nominal life

More information

UA-SS FAQS UA-SS FAQS

UA-SS FAQS UA-SS FAQS 404-1235UA-SS FAQS The links below will work in most PDF viewers and link to the topic area by clicking the link. We recommend Adobe Reader version 10 or greater available at: http://get.adobe.com/reader

More information

Advanced Adaptive Control for Unintended System Behavior

Advanced Adaptive Control for Unintended System Behavior Advanced Adaptive Control for Unintended System Behavior Dr. Chengyu Cao Mechanical Engineering University of Connecticut ccao@engr.uconn.edu jtang@engr.uconn.edu Outline Part I: Challenges: Unintended

More information

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -A - Introduction - Thank for your purchasing MITSUBISHI ELECTRIC MELPRO TM D Series Digital Protection

More information

McQuay Climate Control Singer. Incremental. NE, NH, NR Vintages C, D. TYA, TAA Vintages A, B. Last Manufactured: 1999

McQuay Climate Control Singer. Incremental. NE, NH, NR Vintages C, D. TYA, TAA Vintages A, B. Last Manufactured: 1999 Replacement Parts List No. 055233900 Revision D 08/2017 McQuay Climate Control Singer Incremental NE, NH, NR 07-18 Vintages C, D TYA, TAA 007-015 Vintages A, B Last Manufactured: 1999 To find your Daikin

More information

RECORD AND ANALYSE THE PRESSURE-ENTHALPY DIAGRAM FOR A COMPRESSION HEAT PUMP

RECORD AND ANALYSE THE PRESSURE-ENTHALPY DIAGRAM FOR A COMPRESSION HEAT PUMP Thermodynamics Heat cycles Heat Pump RECORD AND ANALYSE THE PRESSURE-ENTHALPY DIAGRAM FOR A COMPRESSION HEAT PUMP Demonstrate how an electric compression heat pump works Quantitatively investigate of the

More information

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011 SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with

More information

Interactivity-Compatibility. TA Hydronic College Training

Interactivity-Compatibility. TA Hydronic College Training Interactivity-Compatibility TA Hydronic College Training Hydraulic interactivity B Both valves are open. What becomes the flow if one of these valves is closed? p AB A H Head [ft] 140.00 120.00 100.00

More information

EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS. FCP 2008 testing procedures FCP acoustical test method pag. 1

EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS. FCP 2008 testing procedures FCP acoustical test method pag. 1 EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS FCP 2008 testing procedures FCP acoustical test method pag. 1 CONTENTS 1 - PURPOSE... 3 2 - NORMATIVE REFERENCES... 3 3 - DEFINITIONS... 3 3.1

More information

Modular contactors for installation into distribution

Modular contactors for installation into distribution Modular contactors for installation into distribution boards Modular contactors for installation into distribution boards Modular contactor for installation into distribution board Description Modular

More information

A Rain Sensitive House Window Closes Automatically When Raining

A Rain Sensitive House Window Closes Automatically When Raining A Rain Sensitive House Window Closes Automatically When Raining House windows are sometimes opened when it rains and no body around to close them allowing rain going in side and damage the house. Information

More information

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER Model : TM-2000 Your purchase of this THERMOMETER marks a step forward for you into the field of precision measurement. Although this THERMOMETER is a

More information

Non- Iterative Technique for Balancing an. Air Distribution System

Non- Iterative Technique for Balancing an. Air Distribution System Non- Iterative Technique for Balancing an Air Distribution System Mauro Small Thesis presented to the Faculty of Virginia Polytechnic Institute and State University in partial fulfillment of the requirements

More information

HMS-5000 Manual. Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K. - Manual version: ver 5.

HMS-5000 Manual. Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K. - Manual version: ver 5. HMS-5000 Manual Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K - Manual version: ver 5.01- www.ecopia21.co.kr - Table of contents - 1. Hardware Installation

More information

473-SHX Dew Point Mirror

473-SHX Dew Point Mirror Humidity and Temperature Reference Hygrometer For Temperature up to 125 C Precise and stable chilled mirror dew point mirror technology High temperature optical components High temperature sample fan Cable

More information

Dynamic simulation of DH house stations

Dynamic simulation of DH house stations Article Dynamic simulation of DH house stations Jan Eric Thorsen, Director, DHS Application Centre, Danfoss A/S www.danfoss.com Jan Eric Thorsen, Director, DHS Application Centre, Danfoss A/S Presented

More information

Thermal anemometer. We measure it. testo 405. Flow velocity measuring instrument with temperature measurement

Thermal anemometer. We measure it. testo 405. Flow velocity measuring instrument with temperature measurement We measure it. Thermal anemometer testo 405 Flow velocity measuring instrument with temperature measurement Volume flow measurement up to 99,990 m³/h Extendable telescope up to 300 mm m/s C Display illumination

More information

DEVELOPMENT OF THE MEASURING SYSTEM FOR ANALYSING THE THERMAL PROPERTIES OF CLOTHING

DEVELOPMENT OF THE MEASURING SYSTEM FOR ANALYSING THE THERMAL PROPERTIES OF CLOTHING DEVELOPMENT OF THE MEASURING SYSTEM FOR ANALYSING THE THERMAL PROPERTIES OF CLOTHING Dubravko ROGALE; Snježana FIRŠT ROGALE & Ivana ŠPELIĆ Abstract:The measuring system for assessing static and dynamic

More information

AIR COOLED CONDENSING UNIT

AIR COOLED CONDENSING UNIT EVOLUTION SERIES AIR COOLED CONDENSING UNIT OUTDOOR AIR COOLED CONDENSING UNIT ORIGINAL MANUFACTURED EQUIPMENT Evolution Series BA-503-3 AUS Evolution Air Cooled Condensing Unit Series Content Page Explanation

More information

BV SERIES. VERTICAL BLOWER COIL UNITS Nominal Sizes 2 thru 10 Ton

BV SERIES. VERTICAL BLOWER COIL UNITS Nominal Sizes 2 thru 10 Ton BV SERIES VERTICAL BLOWER COIL UNITS Nominal Sizes 2 thru 10 Ton MAGIC AIRE BV SERIES FAN COILS ARE ETL LISTED TO U.S. AND CANADIAN SAFETY STANDARDS AND ARE ASSEMBLED TO ORDER FOR COMPETITIVE DELIVERY.

More information

Old Dominion University Physics 112N/227N/232N Lab Manual, 13 th Edition

Old Dominion University Physics 112N/227N/232N Lab Manual, 13 th Edition RC Circuits Experiment PH06_Todd OBJECTIVE To investigate how the voltage across a capacitor varies as it charges. To find the capacitive time constant. EQUIPMENT NEEDED Computer: Personal Computer with

More information

AIR COOLED CONDENSING UNIT

AIR COOLED CONDENSING UNIT NEW EVOLUTION SERIES AIR COOLED CONDENSING UNIT OUTDOOR AIR COOLED CONDENSING UNIT ORIGINAL MANUFACTURED EQUIPMENT NEW EVOLUTION 7 & 8 SERIES BA-506-5 AUS Evolution Air Cooled Condensing Unit Series Content

More information

E THERMADATA LOGGER Humidity & temperature recording meter

E THERMADATA LOGGER Humidity & temperature recording meter E 07 00 THERMADATA LOGGER Humidity & temperature recording meter THERMADATA LOGGER Data-loggers are electronic devices that record temperature over a period of time for analysis at a later date. The user

More information

Dr. OligoTM DNA / RNA / OLIGO SYNTHESIZERS

Dr. OligoTM DNA / RNA / OLIGO SYNTHESIZERS Dr. OligoTM DNA / RNA / OLIGO SYNTHESIZERS High Throughput Oligo Synthesis Synthesize Cleave Deprotect Desalt Elute Dr. Oligo TM The Dr. Oligo TM High Throughput Oligo Synthesizer is available in four

More information

Clausing Industrial, Inc. Variable Speed 20" Single and Multi-spindle, Belt Drive Industrial Drill Presses

Clausing Industrial, Inc. Variable Speed 20 Single and Multi-spindle, Belt Drive Industrial Drill Presses www.clausing-industrial.com Variable Speed 20" Single and Multi-spindle, Belt Drive Industrial Drill Presses Clausing Industrial, Inc. Two Speed Variable Speeds 150-2000rpm Variable Speeds 200-1300rpm

More information

Remote Display Unit. Installers Handbook Copyright 2001 AirSense Technology Ltd. LM Remote Display Unit Installers Handbook Issue 1.

Remote Display Unit. Installers Handbook Copyright 2001 AirSense Technology Ltd. LM Remote Display Unit Installers Handbook Issue 1. Remote Display Unit Installers Handbook Copyright 2001 AirSense Technology Ltd AirSense, ClassiFire, FastLearn PipeCAD, SenseNET, Stratos-HSSD and Stratos-Quadra are trademarks. HSSD is a Registered Trademark.

More information

Circular air volume controller RWOA

Circular air volume controller RWOA Circular air volume controller RWOA TECHNICAL DATA page 7 Circular air volume controller RWOA Circular air volume controller RWOA enables automatic airflow control. RWOA is suitable for use in systems

More information

Minute Impulse Clock Controller I01DN

Minute Impulse Clock Controller I01DN 99b-mi USER S MANUAL Minute Impulse Clock Controller Mon Jun 01, 2009 12:00:00 PM DST HOLD ENTER KEY TO BEGIN CANCEL HR I01DN 97 West Street Medfield, MA 02052 U.S.A. (508) 359-4396 Pg. 2 of 20 TABLE OF

More information

RC Circuit (Power amplifier, Voltage Sensor)

RC Circuit (Power amplifier, Voltage Sensor) Object: RC Circuit (Power amplifier, Voltage Sensor) To investigate how the voltage across a capacitor varies as it charges and to find its capacitive time constant. Apparatus: Science Workshop, Power

More information

The Vaisala AUTOSONDE AS41 OPERATIONAL EFFICIENCY AND RELIABILITY TO A TOTALLY NEW LEVEL.

The Vaisala AUTOSONDE AS41 OPERATIONAL EFFICIENCY AND RELIABILITY TO A TOTALLY NEW LEVEL. The Vaisala AUTOSONDE AS41 OPERATIONAL EFFICIENCY AND RELIABILITY TO A TOTALLY NEW LEVEL. Weather Data Benefit For Society The four most important things about weather prediction are quality, reliability,

More information

473 Dew Point Hygrometer

473 Dew Point Hygrometer High Performance Chilled Mirror Hygrometer With Cable Mounted Measuring Heads Highly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct

More information

TECHNICAL MANUAL 820 LX / 910 LX / 1300 LX

TECHNICAL MANUAL 820 LX / 910 LX / 1300 LX TECHNICAL MANUAL 820 LX / 910 LX / 1300 LX LANCER reserves the right to modify, constantly its documentation for its improvement. The values of adjustments indicated in the displays of this manual are

More information

Variable Speed 20" Single and Multi-spindle, Belt Drive Industrial Drill Presses

Variable Speed 20 Single and Multi-spindle, Belt Drive Industrial Drill Presses www.clausing-industrial.com Variable Speed 20" Single and Multi-spindle, Belt Drive Industrial Drill Presses Two Speed Variable Speeds 150-2000rpm Variable Speeds 200-1300rpm Variable Speeds 300-2000rpm

More information

6 Securing of the delivery and acceptance

6 Securing of the delivery and acceptance 6 Securing of the delivery and acceptance Sector/Field Ox activities 1 Building Energy consumption 2 Spaces 3 Envelope, walls, roof, base floors, windows and doors Total energy consumption by types of

More information

ISM Evolution. Elscolab. Nederland BV

ISM Evolution. Elscolab. Nederland BV ISM Evolution Agenda Introduction Marketing Strategy ISM Concept & Technology Product Offering Applications Digital Communication and ISM Outlook 1 Agenda Introduction Marketing Strategy ISM Concept &

More information

GS110. IR Thermal Imaging System for Low-Emissivity Glass with Automatic Emissivity Correction. Manual Addendum

GS110. IR Thermal Imaging System for Low-Emissivity Glass with Automatic Emissivity Correction. Manual Addendum GS110 IR Thermal Imaging System for Low-Emissivity Glass with Automatic Emissivity Correction Manual Addendum Rev. B 10/2006 1 Safety Instructions All notices regarding safety and acceptable operation

More information

PAA-ANALYZERS PRINCIPLE OF OPERATION

PAA-ANALYZERS PRINCIPLE OF OPERATION PAA-ANALYZERS PRINCIPLE OF OPERATION The PAA process analyzer comprises a control unit and an analyzing section which includes the reaction chamber and measuring cell, reagent pumps and associated valves

More information

TRAM LINE SWITCH POINT HEATING

TRAM LINE SWITCH POINT HEATING ENERGY SAVING SMART WEATHER CONTROL TRAM LINE SWITCH POINT HEATING 50 80% Energy saving Heating controlled by weather conditions and weather forecast Long life heating elements Shield material is Monel

More information

Better Weather Data Equals Better Results: The Proof is in EE and DR!

Better Weather Data Equals Better Results: The Proof is in EE and DR! Better Weather Data Equals Better Results: The Proof is in EE and DR! www.weatherbughome.com Today s Speakers: Amena Ali SVP and General Manager WeatherBug Home Michael Siemann, PhD Senior Research Scientist

More information

xlogic SuperRelay is a compact and expandable CPU replacing mini PLCs, multiple timers, relays and counters.

xlogic SuperRelay is a compact and expandable CPU replacing mini PLCs, multiple timers, relays and counters. SuperRelay S U P E R R E L A Y, T H E P E R F E C T A L T E R N A T I V E T O L O W C O S T P L C s A N D B A S I C R E L A Y S I N T H I S B R O C H U R E : ELC 18 Standard Models ELC 18 Economy Models

More information

Electrolysis System CHLORINSITU V (PLUS)

Electrolysis System CHLORINSITU V (PLUS) Output of 100 3.500 g/h of ultra-pure active chlorine (hypochlorous acid) Electrolysis systems of the type CHLORINSITU V generate ultrapure active chlorine using the unique vacuum method with the membrane

More information

VT8600 Series BACnet Integration

VT8600 Series BACnet Integration VT8600 Series BACnet Integration BACnet Integration for VT8600 Series Room Controller BACnet CONTROLLER Version 2 2 Table of Contents INTRODUCTION BACnet Compatibility Specifications 3 Analog Objects 4

More information

CONTENTS. Batteries. La Crosse Technology, Ltd Page 1

CONTENTS. Batteries. La Crosse Technology, Ltd Page 1 515-1316 FAQS The links below will work in most PDF viewers and link to the topic area by clicking the link. We recommend Adobe Reader version 10 or greater available at: http://get.adobe.com/reader CONTENTS

More information

2 Verification of the design prerequisites (Design intent)

2 Verification of the design prerequisites (Design intent) 2 Verification of the design prerequisites (Design intent) Sector/Field Qx actions 1 Building Specifications of client requirements Activities within the building a,b Numbers of users: occupants, visitors

More information

Elios X3 DIGITAL CONTROL SYSTEM FOR THE MANAGEMENT OF SOLAR HEAT PLANT

Elios X3 DIGITAL CONTROL SYSTEM FOR THE MANAGEMENT OF SOLAR HEAT PLANT Elios X3 DIGITAL CONTROL SYSTEM FOR THE MANAGEMENT OF SOLAR HEAT PLANT DESCRIPTION Programmable digital control for thermal solar systems inclusive of solar collectors, circulation pumps and / or diverter

More information

Innovative Sustainable Technology

Innovative Sustainable Technology Innovative Sustainable Technology DIG is committed to practices that contribute to irrigation and energy efficiency, creating healthy living conditions while maintaining environmentally sound operating

More information

S Sapling INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS. advanced time and control systems

S Sapling INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS. advanced time and control systems INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS Time base: 60 Hz (3-wire system) Quartz (2-wire system) Power input: 85 135 VAC / 60 Hz 7 28 VAC / 60 Hz Current consumption:

More information

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014 Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM8004 80003223 / 00 05 / 2014 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...4 3 Functions and features...5

More information

WeatherWatcher ACP. Astronomers Control Panel (V4 or >) Ambient Virtual Weather Station (Pro or Internet editions) ASCOM platform v4.

WeatherWatcher ACP. Astronomers Control Panel (V4 or >) Ambient Virtual Weather Station (Pro or Internet editions) ASCOM platform v4. WeatherWatcher ACP Software This is a minimum equipment list: Astronomers Control Panel (V4 or >) Ambient Virtual Weather Station (Pro or Internet editions) ASCOM platform v4.1 or higher Hardware Weather

More information

Rain Watch TM Set up Manual. IC System with Rain Bird IC CONNECT

Rain Watch TM Set up Manual. IC System with Rain Bird IC CONNECT Rain Watch TM Set up Manual IC System with Rain Bird IC CONNECT December 2018 Table of Contents Required materials to configure Rain Watch TM... 3 Installation... 4 Location... 4 Field Installation...

More information

Precision Circuits Inc

Precision Circuits Inc Precision Plex brings to one central location the control of many of the RV s low voltage appliances. In a typical RV wiring scheme, the battery is wired to a fuse block, which distributes power to individual

More information

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically Complete Set ph PRO Controller - 1 pcs. ph electrode - 1 pcs. Calibration

More information

AIR CONDITIONERS 2016 COLLECTION. Window Portable Dehumidifier Through The Wall Ductless Split Units. Online Interactive Edition v.1.

AIR CONDITIONERS 2016 COLLECTION. Window Portable Dehumidifier Through The Wall Ductless Split Units. Online Interactive Edition v.1. AIR CONDITIONERS 2016 COLLECTION Window Portable Dehumidifier Through The Wall Ductless Split Units Online Interactive Edition v.1.1 2016 COLLECTION AIR CONDITIONERS Stay comfortable in any room with an

More information

EXISTING PANEL "22C" CIR.# TYPE DESCRIPTION VOLTAGE 208Y/120V WIRE SIZE EXISTING PANELBOARD SCHEDULE PHASE WIRE NEUTRAL AIC MAIN % (E) 400A MLO

EXISTING PANEL 22C CIR.# TYPE DESCRIPTION VOLTAGE 208Y/120V WIRE SIZE EXISTING PANELBOARD SCHEDULE PHASE WIRE NEUTRAL AIC MAIN % (E) 400A MLO EXISTING PANEL "22C" DESCRIPTION VOLTAGE 208Y/120V WIRE SIZE EXISTING PANELBOARD SCHEDULE PHASE WIRE NEUTRAL AIC MAIN 3 4 100% (E) 400A MLO COND BREAKER LOAD LOAD BREAKER PHASE. SIZE AMP P (KVA) (KVA)

More information

Air distribution systems. Linear whirl outlet WL...

Air distribution systems. Linear whirl outlet WL... Air distribution systems Linear whirl outlet WL... DS 0 E 1.013 Preliminary remarks Mode of operation The linear whirl outlet generates turbulent mixing ventilation. It can be installed on or in a wall

More information

Digital Controller Operation

Digital Controller Operation A Family Company Manufacturing In The USA Since 1969 Full Gauge Digital Controller Operation This manual is specific to the operation and diagnostic guides of the Full Gauge digital controller used in

More information

Swirl Diffusers Type DLA 7 and DLA 8

Swirl Diffusers Type DLA 7 and DLA 8 LTG Incorporated Swirl Diffusers Type DLA 7 and DLA 8 LTG Incorporated 1 Corporate Drive, Suite D Spartanburg, SC 93 PO Box 889, Spartanburg, SC 9 USA Tel: 86-599-63 Fax: 86-599-63 e-mail: info@ltg-inc.net

More information

Installation Instructions

Installation Instructions PACKAGE CONTENTS ITEM QUANTITY Enthalpy Sensor (Part No. HH57AC078) No. 6B, 3 4-in. long Sheet Metal Screw 2 Blue Wire Assembly (256-in. long with 4-in. quick-connect fitting)* Violet Wire Assembly (256-in.

More information

Air distribution systems. Adjustable induction outlet IN-V...

Air distribution systems. Adjustable induction outlet IN-V... ir distribution systems djustable induction outlet IN-V... DS E 0. Construction and function Preliminary remarks In addition to its induction outlet with preset discharge direction ), KRNTZ KOMPONENTEN

More information

RainMachine Mini- 8 Quick- Start Guide

RainMachine Mini- 8 Quick- Start Guide RainMachine Mini- 8 Quick- Start Guide Table of Contents Inside the Box... 3 Wiring Diagram... 4 Hardware Installation... 5 Initial Setup... 6 How it works... 13 Operation... 8 Program Properties... 10

More information

Construction Of A Temperature Controlled Fan Using A Microprocessor.

Construction Of A Temperature Controlled Fan Using A Microprocessor. American Journal of Engineering Research (AJER) e-issn: 2320-0847 p-issn : 2320-0936 Volume-6, Issue-9, pp-324-328 www.ajer.org Research Paper Construction Of A Temperature Controlled Fan Using A Microprocessor.

More information

Designing a Thermostat Worksheet

Designing a Thermostat Worksheet Designing a Thermostat Worksheet Most of us have a thermostat in our homes to control heating and cooling systems of our home. These important devices help us save energy by automatically turning off energy

More information

MASTER TL5 Lamps. The Safety and. fit. TrustSight LED Emergency drivers. A full range of MASTER TL5 Lamps

MASTER TL5 Lamps. The Safety and. fit. TrustSight LED Emergency drivers. A full range of MASTER TL5 Lamps MASTER TL5 Lamps The Safety and perfect peace of mind fit TrustSight LED Emergency drivers A full range of MASTER TL5 Lamps Philips MASTER TL5 Lamps Today s proven standard It s been more than a decade

More information

A PRELIMINARY MODEL OF USER BEHAVIOUR REGARDING THE MANUAL CONTROL OF WINDOWS IN OFFICE BUILDINGS

A PRELIMINARY MODEL OF USER BEHAVIOUR REGARDING THE MANUAL CONTROL OF WINDOWS IN OFFICE BUILDINGS Ninth International IBPSA Conference Montréal, Canada August 15-18, 2005 A PRELIMINARY MODEL OF USER BEHAVIOUR REGARDING THE MANUAL CONTROL OF WINDOWS IN OFFICE BUILDINGS Sebastian Herkel, Ulla Knapp and

More information

Air distribution systems. Jet nozzle DW-N2... Swivel jet nozzle DW-V2... Twist nozzle DW-V2-...-DR

Air distribution systems. Jet nozzle DW-N2... Swivel jet nozzle DW-V2... Twist nozzle DW-V2-...-DR Air distribution systems Jet nozzle DW-N... Swivel jet nozzle DW-V... Twist nozzle DW-V-...-DR DS E 01. Jet nozzle and twist nozzle Preliminary remarks Jet nozzle DW N Swivel jet nozzle DW V Twist nozzle

More information

Physical Structure of Matter Hall effect in p-germanium with Cobra3. Solid-state Physics, Plasma Physics.

Physical Structure of Matter Hall effect in p-germanium with Cobra3. Solid-state Physics, Plasma Physics. Physical Structure of Matter Solid-state Physics, Plasma Physics Hall effect in p-germanium with Cobra3 What you can learn about Semiconductor Band theory Forbidden zone Intrinsic conductivity Extrinsic

More information

PARTS CATALOG. No. OBB702 REVISED EDITION-C. Models

PARTS CATALOG. No. OBB702 REVISED EDITION-C. Models Revision C: MXZ-3C24/3C30/4C36/5C42NA2 and MXZ-2C20/3C24/3C30NAHZ2 have been added. Please void OBB702 REVISED EDITION-B. OUTDOOR INDOOR UNIT UNIT PARTS CATALOG No. OBB702 REVISED EDITION-C Models MXZ-3C24NA

More information

air and solenoid air operated 5/2-5/3 ISO 5599/01 - Size 2

air and solenoid air operated 5/2-5/3 ISO 5599/01 - Size 2 Series 4/PH MULTIFUNCTION SPOOL VALV air and solenoid air /-/ ISO 99/0 - Size ports / positions SPCIFICATIONS FLUID : or neutral gas, filtered, lubricated or not PRSSUR : 0,90 to + bar (can be used with

More information

5SJ4...-.HG Circuit Breakers to IEC and UL 489

5SJ4...-.HG Circuit Breakers to IEC and UL 489 Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET MAGNA, UPE Series circulator pumps Contents Product data MAGNA and UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids Type key

More information