Rectangular air volume controller RWPA
|
|
- Esther Foster
- 5 years ago
- Views:
Transcription
1 Rectangular air volume controller RWPA TECHNICAL DATA page 189 Rectangular air volume controller RWPA Rectangular air volume controller RWPA enables automatic airflow control. RWPA is suitable for use in systems with variable air volume VAV and in other cases, where constant air flow is required. Regulator can work in connection with other automatic control devices e.g. quality-quantity temperature control systems. RWPA complies with requirements for air tightness of class CEN 2. Product facts Rectangular air volume controller RWPA Intended for air volume regulation Acoustically insulated or uninsulated Available in vast number of sizes Product code eample: Controller RWPA VAV bo of width and height 20 cm, without acoustic insulation, equipped with Grüner 2VM actuator, standard airflow Fläkt Woods PLBOV
2 Rectangular air volume controller RWPA TECHNICAL DATA page 190 Scheme, operative principle RWPA schematic diagram Measurement pipes Damper Differential pressure converter Damper actuator P Regulator Set value input (0(2)-10V) Actual signal output (0(2)-10V) or MP-Bus function Operative principle Signal from measurement elements is converted by differential pressure converter onto electric signal and then transmitted to regulator. Regulator controls damper actuator accordingly to the result of set and measured value comparison. Standarly RWPA VAV bo is equipped with compact actuator 2VM manufactured by Grüner. Other automatic solutions are available on request. Controller has limiting flow value V GR preset by manufacturer. Fläkt Woods compact actuator 2VM is a complete unit comprising of actuator, a dynamic differential pressure sensor for pressure-independent controls and user interface with 3-digit display which enables monitoring the air flow and setting up values of V ma and V min without eternal equipment. The actuator can also be force controlled via closing contacts (timer, presence detector, etc.) to override the set min or ma air flow. It is also possible to use the controller with a CAV function. Fläkt Woods PLBOV
3 Rectangular air volume controller RWPA TECHNICAL DATA page 191 Operating range, dimensions Operating range of particular controller sizes Following table shows recommended minimum V min [m 3 /h] and limiting V GR [m 3 /h] airflow value preset by manufacturer (*): H (cm)/b (cm) (*) Other settings of V GR value on request. V ma corresponds to air going through the VAV bo with velocity of 8 m/s. V min corresponds to air going through the VAV bo with velocity of 1 m/s. Change of operation point % V MAX 100%V NOM 10V 10V Reference value input (0)2...10V 2V 0V 0% V MIN 100%V NOM Bo without acoustic insulation E=B+85* 20* H H 1 =H+* B B 1=B+* 0 Fläkt Woods PLBOV
4 Rectangular air volume controller RWPA TECHNICAL DATA page 192 Dimensions, installation guidelines Bo with acoustic insulation E=C+ H H =H+* 1 D=H+ B B=B+* 1 C=B+ 0 *) Dimensions given in mm. If one of the dimensions B or H is equal to or greater than mm: frame width = mm RWPA bo schedule (*) H (cm)/b (cm) (*) Other dimensions available on request Installation guidelines Due to accuracy of airflow control it is recommended to install RWPA bo in a certain distance from other elements of ventilation system which may disturb the airflow pattern. Rules of controller's installation are shown below: Fläkt Woods PLBOV
5 Rectangular air volume controller RWPA TECHNICAL DATA page 193 Wiring diagrams Eamples of RWPA electric connections - compact actuator Grüner 2VM Parallel control of two flow variators Master-Slave control of two flow variators CAV Constant air volume Forced control Detailed technical data can be found in technical brochure of actuator. Fläkt Woods PLBOV
6 Rectangular air volume controller RWPA TECHNICAL DATA page 194 Wiring diagrams Eamples of RWPA electric connections - compact actuator Belimo (L,N)MV-D3-MP Parallel control of two flow variators Master-Slave control of two flow variators CAV Constant air volume Control via MP-Bus Fläkt Woods PLBOV
7 Rectangular air volume controller RWPA TECHNICAL DATA page 195 Application eamples Maintaining constant airflow in ventilation duct Air volume controller maintains constant airflow according to the given V min value. RWPA P Wł Cooperation with room temperature sensor Constant change of airflow within the range from V min to V ma, depends on reference signal coming from room temperature controller. + RWPA P Maintaining constant pressure in ventilation duct or premise RWPA P Wł In this case airflow measurement elements are not used. One input of the pressure converter is connected to premise space or ventilation duct. Fläkt Woods PLBOV
8 Rectangular air volume controller RWPA TECHNICAL DATA page 196 Acoustic data Following tables show sound power levels [db] in octave bands and sound power levels for various air velocities and pressure drops over device. For controllers which width B is other than 0 mm, read data must be corrected by L factor. Total sound power level can be calculated using following formula: L TOT = L WA + L Sound power level at outlet RWPA Pa 0 Pa RWPA Pa 0 Pa RWPA 00 2 Pa 0 Pa RWPA 00 2 Pa 0 Pa RWPA 00 2 Pa 0 Pa RWPA 00 2 Pa 0 Pa 81 Fläkt Woods PLBOV
9 Rectangular air volume controller RWPA TECHNICAL DATA page 197 Acoustic data RWPA 00 2 Pa 0 Pa RWPA 00 2 Pa 0 Pa RWPA Pa 0 Pa Correction factor L for various widths B of the regulator B (cm) L (db) Sound power level emitted to surrounding, controller without acoustic insulation RWPA Pa 0 Pa RWPA Pa 0 Pa RWPA 00 2 Pa 0 Pa Fläkt Woods PLBOV
10 Rectangular air volume controller RWPA TECHNICAL DATA page 198 Acoustic data RWPA 00 2 Pa 0 Pa RWPA 00 2 Pa 0 Pa RWPA 00 2 Pa 0 Pa RWPA 00 2 Pa 0 Pa RWPA 00 2 Pa 0 Pa RWPA Pa 0 Pa Sound power level emitted to surrounding, controller with acoustic insulation RWPA Pa 0 Pa Fläkt Woods PLBOV
11 Rectangular air volume controller RWPA TECHNICAL DATA page 199 Acoustic data RWPA Pa 0 Pa RWPA 00 2 Pa 0 Pa RWPA 00 2 Pa 0 Pa RWPA 00 2 Pa 0 Pa RWPA 00 2 Pa 0 Pa RWPA 00 2 Pa 0 Pa RWPA 00 2 Pa 0 Pa Fläkt Woods PLBOV
12 Rectangular air volume controller RWPA TECHNICAL DATA page 200 Pressure drop, descriptive tet, product code Pressure drop over RWPA controller (damper fully open) P [Pa] , v[m/s] Product code Air volume controller RWPA-aaa-bbb-c-d-e Width (cm) 020, 0, 0, 0, 0, 0, 0, 0, 0, 100, 120 Height (cm) 010, 020, 0, 0, 0 0, 0, 0, 100 Acoustic insulation 0 - without 1 - with Type of actuator 1 - Belimo NMV-D3-MP 2 - Belimo NM-V and VRD Siemens GLB181.1E 4 - Grüner 2VM (Fläktwoods branded) Airflow 1 - standard X - non-standard Fläkt Woods PLBOV
13
Circular air volume controller RWOA
Circular air volume controller RWOA TECHNICAL DATA page 7 Circular air volume controller RWOA Circular air volume controller RWOA enables automatic airflow control. RWOA is suitable for use in systems
More informationWISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS
Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS Variable or constant flow regulation or constant pressure regulation Wireless communication via radio Integrated sensor
More informationKZPb
---------------------------------------------------------- ---------------------------------------------------------------------- Electronic constant pressure regulator FUNCTION KZP is an electronic pressure
More informationDamper - circular. Dimensions. Description. Ordering example. comfort vav
Dimensions L D B C H Ød Description is a circular control and shut-off damper, which meets the air tightness requirements of DS class. The damper can be used for pressure or volume flow regulation with
More informationvariable flow dampers
Constant-/ DAU, DAEU, DAVU Summary DAU - manual single flow unit DAEU - motorized twin flow unit DAVU - motorized variable flow unit Diameters Ø 0 Flow range 0 l/s ( m³/h) Pressure range Pa (over the unit)
More informationKZMb
-------------------------------------------------------- Electronic zone controller for pressure regulation ---------------------------------------------------------------------- FUNCTION KZM is an electronic
More informationKSAb
--------------------------------------------------------- ---------------------------------------------------------------------- Electronic slave and constant flow regulator for air flow regulation FUNCTION
More informationMechanical flow-rate controllers
L D L D L D Mechanical flow-rate controller MRP-1 (Circular) Description With the circular air flow controllers with automated action, the air flow rate is controlled via an asymmetrical control flap pivoting
More informationKrantz Components. Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems
Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems DS E 01. with guide ring or jet straightener Preliminary remarks The variable twist outlet with guide ring
More informationKrantz. Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems
Krantz Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems DS E 01.18 Variable twist outlet with guide ring or jet straightener Preliminary remarks The variable
More informationVK2 volume flow controller Overview
New option with sound attenuator Maintenance-free VK2 volume flow controller that operates without an auxiliary power supply, for ventilation and air conditioning systems. Adjustable on site. Outstanding
More informationAir distribution systems. Adjustable radial outlet RA-V...
Air distribution systems Adjustable radial outlet RA-V... DS E 0.2013 Construction design Preliminary remarks KRANTZ KOMPONENTEN has developed its wellknown, successful radial outlet into an adjustable
More informationAir distribution systems. Linear whirl outlet WL...
Air distribution systems Linear whirl outlet WL... DS 0 E 1.013 Preliminary remarks Mode of operation The linear whirl outlet generates turbulent mixing ventilation. It can be installed on or in a wall
More informationCircular duct grille. Dimensions. Description. Maintenance The grille should be removed to gain access to the duct.
Dimensions B+0 A+0 A B Description RGS is a rectangular ventilation grille with vertical adjustable bars for direct installation in circular ducts. The grille can be used for both supply and exhaust air.
More informationSV-2, SV-1, AVS, AVSL, SI Grilles
Grilles SV-2, SV-1, AVS, AVS-L TECHNICAL DATA - 2004 page 351 SV-2, SV-1, AVS, AVSL, SI Grilles SV-2 SV-1 47 (H-17) x (W-17) (H-12) x (W-12) AVS, SI AVSL S SV, AVS, AVSL and SI grilles are designed for
More informationCircular duct grille
Dimensions B+0 A+0 A B Description is a rectangular ventilation grille with vertical adjustable bars for direct installation in circular ducts. The grille can be used for both supply and exhaust air. The
More informationCDD/CDR. Circular ceiling diffuser for supply air QUICK FACTS
Circular ceiling diffuser for supply air QUICK FACTS Spread pattern can be shielded Used with commissioning box ALS Cleanable Adjustable slot Perforated diffuser face = CDD Non-perforated diffuser face
More informationALC. ALBATROSS Supply air terminal for large airflows
ALBATROSS Supply air terminal for large airflows Quick facts Large airflows Suitable for cooling or heating Manual or motorised adjustment Pressure drop independent of selected spread pattern Can be used
More informationEUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS. FCP 2008 testing procedures FCP acoustical test method pag. 1
EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS FCP 2008 testing procedures FCP acoustical test method pag. 1 CONTENTS 1 - PURPOSE... 3 2 - NORMATIVE REFERENCES... 3 3 - DEFINITIONS... 3 3.1
More informationThe diagram below. to the by the. outlet into. calculation. Since TRANSMISSION VIA STRUCTURE. Vibration Via Supports Duct Breakout
NOISE CONTROL IN VENTILATING SYSTEMS INTRODUCTION The diagram below shows the various noise sources and transmission paths of plant rooms and ventilation systems. For the ventilation system this can be
More informationGrille. Min. - max. dimensions
Min. - max. dimensions H L 0 00 75 00 Standard grilles are available with mm pitch within the above min. and max. sizes. Customized sizes available on request. Description is an adjustable single or double
More informationNozzles. About Lindab. Comfort and Design. Product overview / symbols. Theory. Ceiling diffusers. Ceiling diffusers - visible.
Nozzles About Lindab Comfort and Design Product overview / symbols Theory Ceiling diffusers Ceiling diffusers - visible Plenum boxes Wall diffusers Nozzles Ventiduct Grilles Displacement diffusers VAV
More informationVariable swirl diffusers
Swirl diffusers, Variable swirl diffuser OD- Application Diffuser is designed for air conditioning of rooms with floor to ceiling highs of to 0 m and high induction requirements. It is suitable for large
More informationAX6 adjustable blades swirl diffusers
AX6 adjustable blades swirl diffusers AX6 series swirl diffusers are designed to be applied in air conditioning, ventilation and heating in different premises from 2,6 meters high and temperature differential
More informationWater terminal control solutions
Water Terminal Control Solutions Water terminal control solutions Carrier offers a wide range of fan coil units designed to meet the needs of different systems and applications: from cabinet units in the
More informationGTH. Rectangular double deflection grille QUICK FACTS
Rectangular double deflection grille QUICK FACTS For supply air Adjustable air deflectors Cleanable Installed using mounting frames FHB / FHA or commissioning box TRG Available in alternative colours A
More informationCDD/CDR. Single cone ceiling diffusers for supply air. Quick facts. Quick guide CDD/CDR A I R F L O W - S O U N D L E V E L
Single cone ceiling diffusers for supply air Quick facts Spread pattern can be shielded Used with commissioning box ALS Cleanable Adjustable slot Perforated diffuser face = CDD Imperforated diffuser face
More informationAir distribution systems. Jet nozzle DW-N2... Swivel jet nozzle DW-V2... Twist nozzle DW-V2-...-DR
Air distribution systems Jet nozzle DW-N... Swivel jet nozzle DW-V... Twist nozzle DW-V-...-DR DS E 01. Jet nozzle and twist nozzle Preliminary remarks Jet nozzle DW N Swivel jet nozzle DW V Twist nozzle
More informationAir distribution systems. Radial outlet RA-N2...
Air distribution systems Radial outlet RA-N... DS E 0.01 Radial outlet RA-N Preliminary remark KRANTZ KOMPONENTEN radial outlets RA-N have fixed radial vanes and are available with circular or square face.
More informationGRC. Circular egg crate grille for transfer/extract air and wall/ceiling mounting QUICK FACTS
Circular egg crate grille for transfer/extract air and wall/ceiling mounting QUICK FACTS For exhaust air 91% free area Handles large airflows Cleanable Can be used with commissioning box ALS Standard colour
More informationWorth noting. Introduction. Key figures. lindab architect. Picture 1. Architect Circum, Luna and Prisma.
Contact, Overview, Index Guideline heating and cooling Plexus Professor / Professor Plus Premum / Premax / Solus Architect Polaris I & S Plafond Podium Celo Cabinett Capella Carat Fasadium Atrium / Loggia
More informationEcolibrium. All natural. A new style for supermarkets? THE OFFICIAL JOURNAL OF AIRAH AUGUST 2017 VOLUME 16.7 RRP $14.95
THE OFFICIAL JOURNAL OF AIRAH Ecolibrium AUGUST 2017 VOLUME 16.7 RRP $14.95 PRINT POST APPROVAL NUMBER PP352532/00001 All natural A new style for supermarkets? ESTABLISHED 1947 Celebrating 70 years as
More informationSlot diffusers. Slot diffusers, Round duct diffusers. Slot diffusers. Slot diffusers LD-13, LD-14
, Round duct diffusers D-, D- Application D- and D- slot diffusers are designed for the supply of air in rooms with floor to ceiling heights of.5 to m for supplying either cold or warm air, in particular
More informationSiv-inn School. Complete air-supply solution for school premises. Ensures excellent air supply Cleanable Reinforced front Ideal for renovation work
GB0702 11.15 Complete air-supply solution for school premises Ensures excellent air supply Cleanable Reinforced front Ideal for renovation work TROX Trox Norge AS PO Box NO-2712 Brandbu Telefon +47 61
More informationNEO-V. Smoke Control Damper SMOKE CONTROL FUNCTION APPLICATION DESCRIPTION. in libraries of
OKE CONTRO in libraries of EI (v ew -h ow -i o) 0 C 000 AA multi EN -:0 EN -:0 Certificate of Constancy of Performance -CPR-0/00 Damper tightness class: Casing tightness class: C EN-:0 FUNCTION The smoke
More informationPELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS
Square ceiling air diffuser for supply air and extract air QUICK FACTS Flexible distribution pattern, yet the acoustic data remains the same One K-factor regardless of distribution pattern Designed for
More informationMulti-cone diffuser. Dimensions
Dimensions Vertical Ød 8 Max. H ØU ØD Horizontal Ød Description is an adjustable circular multi-cone diffuser, which is typically used for supply air. The diffuser can be switched between horizontal and
More informationConstant-/variable flow damper
lindab constant -/ariable flow dampers Constant-/ariable flow damper DAU Dimensions B Ød l Description Constant flow damper with manual setting of one flow DAU is a constant flow damper, which facilitates
More informationSWIFT Ceiling. Square ceiling air diffuser for supply air QUICK FACTS
Square ceiling air diffuser for supply air QUICK FACTS Flush design Also available in a version for extract air. Designed for modular suspended ceilings (600 x 600 mm) Quick Access Adapter for systemized
More informationKrantz Components. Twist outlet DD-N... for ceiling installation. Air distribution systems
Krantz Components Twist outlet DD-N... for ceiling installation Air distribution systems DS E 0. Twist outlet Preliminary remarks and construction design Preliminary remarks Twist outlets for ceiling installation
More informationEXPERIMENTAL INVESTIGATION OF NOISE PARAMETERS IN HVAC SYSTEMS
The 40 th International Conference on Mechanics of Solids, Acoustics and Vibrations & The 6th International Conference on Advanced Composite Materials Engineering ICMSAV2016& COMAT2016 Brasov, ROMANIA,
More informationConstant flow damper
Constant flow damper DAU Dimensions B Ød l Description Constant flow damper with manual setting of one flow DAU is a constant flow damper, which facilitates balancing of entilation systems and gies correct
More informationAXO adjustable vanes swirl diffusers
klin SYSTEM XO adjustable vanes swirl diffusers M DEL The XO swirl diffusers are designed to be applied in air conditioning ventilation and heating systems.they can be mounted in false ceilings or suspended
More informationSWIFTTM. Ceiling. Square ceiling air diffuser for supply air
SWIFTTM Ceiling SWIFT Ceiling Square ceiling air diffuser for supply air Quick facts Flush design Also available in a version for extract air. Designed for modular suspended ceilings (600 x 600 mm) Quick
More informationAir distribution systems. Adjustable induction outlet IN-V...
ir distribution systems djustable induction outlet IN-V... DS E 0. Construction and function Preliminary remarks In addition to its induction outlet with preset discharge direction ), KRNTZ KOMPONENTEN
More informationPlain diffuser. Dimensions
Dimensions ØU Ød 22 37 ØD Description is a circular diffuser with unperforated face plate and can be used for both supply and extract air. is suitable for horizontal supply of cooled air where a high impulse
More informationNozzle diffuser. Dimensions
Nozzle diffuser GTI Dimensions Installation Ød Description GTI is a flexible supply air nozzle that is suitable for ventilation of large areas. The nozzle can be used for both heated and cooled air and
More informationISO 5136 INTERNATIONAL STANDARD. Acoustics Determination of sound power radiated into a duct by fans and other air-moving devices In-duct method
INTERNATIONAL STANDARD ISO 5136 Second edition 2003-04-01 Acoustics Determination of sound power radiated into a duct by fans and other air-moving devices In-duct method Acoustique Détermination de la
More informationHELLA. Linear slot diffuser. Ordering codes. HELLA - Linear diffuser. Linear Diffusers 1 / 18. Example of the ordering code HELLA B-0-0-AN
Linear Diffusers / 8 HELLA Linear slot diffuser Ordering codes HELLA - Linear diffuser HELLA - Number of slots... Diffuser length L (mm) ) Increment mm... Deflector colour Damper Diffuser construction
More informationDimensions. Order code. Materials and finish. lindab ceiling diffusers
LKP Description LCP is a flush-mounted square diffuser with a circular unperforated face plate for installation in ceiling systems. LCP can be used for both supply and exhaust air. LCP is suitable for
More informationAddendum to ARI Standard , Air Terminals September 2002
Addendum to ARI Standard 880-98, Air Terminals September 2002 The September 2002 Addendum to ARI Standard 880-98, Air Terminals, is comprised of only the shaded portions shown, which has been incorporated
More informationIndustrial Air Diffuser Type DLD for Heating and Cooling
LTG Incorporated Industrial Air Diffuser Type DLD for Heating and Cooling LTG Incorporated Corporate Drive, Suite E Spartanburg, SC 20 PO Box 288, Spartanburg, SC 20 USA Tel: 8--0 Fax: 8-- e-mail: info@ltg-inc.net
More informationEPIV electronic pressure-independent characterised control valve EPIV
electronic pressure-independent characterised control valve Table of contents The electronic characterised control valve () Project planning 4 Selection and dimensioning 5 Constant flow volume V 5 Valve
More informationPELICAN Ceiling HF. Square extract air diffuser QUICK FACTS
Square extract air diffuser QUICK FACTS Perforated air diffuser front face Manages large extract airflows Flush design Designed for modular suspended ceilings Quick Access front face Can be combined with
More informationSome considerations on noise monitoring for air handling equipments
IOP Conference Series: Materials Science and Engineering PAPER OPEN ACCESS Some considerations on noise monitoring for air handling equipments To cite this article: C Bujoreanu and M Benchea 2017 IOP Conf.
More informationLinear diffuser. Description
A C B + D Description is a rectangular linear diffuser in aluminium. is suitable for both supply and exhaust air. is equipped with air guide baffles, making it possible to use for horizontal supply air.
More informationMulti-cone diffuser. Dimensions. Description FKD is an adjustable circular multi-cone diffuser, which is typically used for supply air.
Dimensions Vertical Ø N D F G Ø A Ø B C Horizontal Description is an adjustable circular multi-cone diffuser, which is typically used for supply air. The diffuser can be switched between horizontal and
More informationPELICAN Ceiling. Square ceiling air diffuser for supply air and extract air
Ceiling Square ceiling air diffuser for supply air and extract air Quick facts Flexible distribution pattern, yet the acoustic data remains the same One K-factor regardless of distribution pattern Designed
More informationKrantz. RL-C2 radial slot outlet. Air distribution systems
RL-C2 radial slot outlet Air distribution systems DS E 04.1 Introduction The RL-C2 radial slot outlet with circular face generates a turbulent mixed flow. It is used for supply and return air distribution
More informationKrantz. Radial slot outlet with square blade array RL-Q2... circular blade array RL-R2... Air distribution systems DS 4186 E 09.
Krantz Radial slot outlet with square blade array RL-Q2... circular blade array RL-R2... Air distribution systems DS 86 E 09./1 with square and circular blade array Preliminary remark The radial slot outlet
More informationOperating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04
Operating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04 UK 80223776 / 00 11 / 2018 Contents 1 Preliminary note...3 2 Safety instructions...4 3 Functions and features...4 4 Function...5
More informationBNA Series. PLENUM FAN with Backward Wheels
BNA Series PLENUM FAN with Backward Wheels BNA Series BNA Series Plenum Fans Backward wheels Kruger Plenum Fans are designed for air handling applications where the fan operates unhoused within a plenum.
More informationKSV. Slot diffusers. Ordering code. Description. Linear diffusers 1 / 16
Linear diffusers 1 / 1 KSV Slot diffusers Ordering code Number of slots Diffuser Length (mm) KSV - 1... - 19 Description KSV is an air terminal element primarily designated for air supply. It is suitable
More informationSupply air beam. Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor / Professor Plus. Premum / Premax / Solus.
Contact, Overview, Index Guideline heating and cooling Plexus Professor / Professor Plus Premum / / Solus Architect Polaris I & S Plafond Podium Celo Cabinett Capella Carat Fasadium Atrium / Loggia Regula
More information6-way valve with room temperature controller. Balanced climate control. World premiere! e. Cost and energy economies
6-way valve with room temperature controller. Balanced climate control. We set standards. www.belimo.eu World premiere! e Virtuoso performance to raise comfort and cut costs. Sustainable well-being hinges
More informationFundamentals of silencing and their practical application in screw compressor plants
Fundamentals of silencing and their practical application in screw compressor plants Dr.-Ing. Johann Lenz Theory of sound Air or fluid-borne sound is generally considered as weak pressure fluctuations.
More information2/S11. v 2.6 (en) SLOT DIFFUSER
/ v.6 (en) www.klimaoprema.hr www.klimaoprema.hr TABLE O CONTENT lot diffuser, type... 7 election diagrams... Ordering key... Corner section... Horizontal one-sided discharge Definition of symbols: Vp
More informationElectronic pressure-independent characterised control valve EPIV
Electronic pressure-independent characterised control valve Table of contents The electronic characterised control valve () Project planning 4 Selection and dimensioning 5 Constant flow volume V 5 Valve
More informationPlain diffuser. Dimensions
Dimensions Ø U Ød B C Ø E Ø A Description is a circular diffuser with an unperforated adjustable face plate and can be used for both supply and extract air. The diffuser can be switched between horizontal
More informationDBQ Painted four four-way square square diffuseurs M A D E L
Painted four-way square diffuseurs MADEL The four-way square diffusers meet the functional and architectural requirements of modern updated locations. Its geometrical shape, fits perfectly in the style
More informationSwirl diffusers, Variable swirl diffusers Swirl diffusers
IMP Klima, Variable swirl diffusers Swirl diffuser OD- Fixed grille For air supply or exhaust Recommended temperature difference between supplied and internal air in the room is between 0 to 0 K Low static
More informationPart 2: Methods for special reverberation test rooms
Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 3743-2 Second edition 2018-02 Acoustics Determination of sound power levels of noise sources using sound pressure Engineering methods for small,
More informationPeriodic Inspection and Testing of Electrical Installations Sample Test ( ) Version 1.3 July 2018
Periodic Inspection and Testing of Electrical Installations Sample Test (2391-051) Version 1.3 July 2018 Sample Questions Version and date Change detail Section 1.3 July 2018 Modified questions/answers
More informationSound power level measurement in diffuse field for not movable sources or emitting prominent discrete tones
CFA 2018 - Le Havre Sound power level measurement in diffuse field for not movable sources or emitting prominent discrete tones F. Bessaca et P. Cellardb a CETIAT, Domaine Scientifique de la Doua, 25,
More informationCalibration of Temperature Block Calibrators
European Association of National Metrology Institutes Calibration of Temperature Block Calibrators EURAMET cg-13 Version 2.0 (03/2011) Previously EA-10/13 Calibration Guide EURAMET cg-13 Version 2.0 (03/2011)
More information5SJ4...-.HG Circuit Breakers to IEC and UL 489
Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is
More informationSound Rating of Ducted Air Moving and Conditioning Equipment
AHRI Standard 260 (I-P) 2017 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment IMPORTANT SAFETY DISCLAIMER AHRI does not set safety standards and does not certify or guarantee the
More informationUse. Worth noting. Key figures. Installation. lindab fasadium
Contact, Overview, Index Guideline heating and cooling Plexus Professor / Professor Plus Premum / Premax / Solus Architect Polaris I & S Plafond Podium Celo Cabinett Capella Carat Atrium / Loggia Regula
More informationSwirl diffusers, Variable swirl diffusers
0 Variable swirl diffusers SLOT IFFUSERS, ROUN UCT IFFUSERS SWIRL IFFUSERS, VARIABLE SWIRL IFFUSERS CIRCULAR IFFUSERS, SQUARE IFFUSERS VENTILATING GRILLES, VENTILATING VALVES, Variable swirl diffusers
More informationEA Guidelines on the Calibration of Temperature Indicators and Simulators by Electrical Simulation and Measurement
Publication Reference EA-10/11 EA Guidelines on the Calibration of Temperature Indicators and Simulators by Electrical PURPOSE This document has been produced by EA as a means of giving advice for calibrating
More informationLECTURE-11 FAN AND DUCT SYSTEM-2
L ecturer: -D D r. E sam M ejbil A bid Subject: A ir Conditioning and R efrigeration Year: Y Fourth B.Sc. D E P A R TM E N O F M E CH A N ICA L E N G IN E E R IN B abylon U niversity College of E ngineering
More informationNozzle diffuser. Dimensions
Dimensions ØU Ød H 0 ØA Description is a circular diffuser with individually adjustable nozzles. The diffuser is suitable for the horizontal supply of cooled air, where great flexibility in the dispersal
More informationLABORATORY MEASUREMENT OF SOUND ABSORPTION OF SONOGLASS SPRAY-ON TREATMENT IN THREE CONFIGURATIONS
LABORATORY MEASUREMENT OF SOUND ABSORPTION OF SONOGLASS SPRAY-ON TREATMENT IN THREE CONFIGURATIONS Prepared for: MONOGLASS INC. 922-1200 West 73rd Avenue Vancouver, BC, Canada V6P 6G5 Prepared by: THE
More informationSupply air nozzle. Dimensions. DAD-0 With flange for mounting on a wall or duct side.
A imensions A-0 With flange for mounting on a wall or duct side. Ø ( ) 0 Ø F Ø Nom 0 0 Ø A Ø B Ø E escription A is an adjustable supply air nozzle suitable for ventilation of large areas where long throws
More informationComparison of discharge measurements -
Comparison of discharge measurements - Thermodynamic to US Clamp-On, stationary US and Needle Opening Curve IGHEM 2012 Trondheim, 2012-06-28/29 1 Comparison of discharge measurements 1. Introduction 2.
More informationApplied Fluid Mechanics
Applied Fluid Mechanics 1. The Nature of Fluid and the Study of Fluid Mechanics 2. Viscosity of Fluid 3. Pressure Measurement 4. Forces Due to Static Fluid 5. Buoyancy and Stability 6. Flow of Fluid and
More informationValve Supply and exhaust air
IRY Dimensions Description The valve is designed for installation at a wall or in a ceiling. It can be used for new-build and for replacement. Its smart grip function ensures an easy installation. Its
More informationApplied Fluid Mechanics
Applied Fluid Mechanics 1. The Nature of Fluid and the Study of Fluid Mechanics 2. Viscosity of Fluid 3. Pressure Measurement 4. Forces Due to Static Fluid 5. Buoyancy and Stability 6. Flow of Fluid and
More informationSupply air beam. Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor / Professor Plus. Premum / Premax / Solus.
Contact, Overview, Index Guideline heating and cooling Plexus Professor / Professor Plus Premum / Premax / Architect Polaris I & S Plafond Podium Celo Cabinett Capella Carat Fasadium Atrium / Loggia Regula
More informationinter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE
Copyright SFA - InterNoise 2000 1 inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering 27-30 August 2000, Nice, FRANCE I-INCE Classification: 1.1 DESIGN OF TERMINATING
More informationHVAC Clinic. Duct Design
HVAC Clinic Duct Design Table Of Contents Introduction... 3 Fundamentals Of Duct Design... 3 Pressure Changes In A System... 8 Example 1... 13 Duct Design Methods... 15 Example 2... 15 Introduction The
More informationISO INTERNATIONAL STANDARD. Acoustics Acoustic insulation for pipes, valves and flanges
INTERNATIONAL STANDARD ISO 15665 First edition 2003-08-15 Acoustics Acoustic insulation for pipes, valves and flanges Acoustique Isolation acoustique des tuyaux, clapets et brides Reference number ISO
More informationConsultancy Report Ref: 9383-R01
Consultancy Report Ref: 9383-R01 Submitted to: Prepared by: Mr Tim Simmons The Woolley Shepherd Secret Meadow Weekmoor Milverton Taunton TA4 1QE John Fithyan Laboratory Manager Approved for issue by: Andy
More informationStandard Practices for Air Speed Calibration Testing
Standard Practices for Air Speed Calibration Testing Rachael V. Coquilla Bryza Wind Lab, Fairfield, California Air speed calibration is a test process where the output from a wind measuring instrument
More informationAeroacoustic simulation of automotive ventilation outlets
Aeroacoustic simulation of automotive ventilation outlets J.-L. Adam a, D. Ricot a, F. Dubief a and C. Guy b a Renault SAS, 1 avenue du golf, 78288 Guyancourt, France b Ligeron, Les Algorithmes Bâtiment
More informationDCG adjustable core circular diffusers
Lievore, Altherr & Molina DCG adjustable core circular diffusers The DCG series diffusers are designed to be used in air-conditioning, ventilation and heating in premises from,6 meters high. They can be
More informationLINEAR SOURCES WITH NON-LINEAR DISTRIBUTION OF SOUND ENERGY. Miroslav Kučera, Richard Nový, Jiří Bašta
ICV14 Cairns Australia 9-1 July, 007 LINEAR OURCE ITH NON-LINEAR DITRIBUTION OF OUND ENERGY Miroslav Kučera, Richard Nový, Jiří Bašta Czech Technical University in Prague, Faculty of Mechanical Engineering
More informationSlot diffuser. Type VSD35 2/2.6/B/3. with 35 mm wide slot
2/2.6/B/3 Slot diffuser Type VSD35 with 35 mm wide slot TROX UK Ltd Telephone +44 (0) 1842 754545 Caxton Way Telefax +44 (0) 1842 763051 Thetford e-mail trox@troxuk.co.uk Norfolk IP24 3SQ www.troxuk.co.uk
More informationEffect of Length and Porosity on the Acoustic Performance of Concentric Tube Resonators
Effect of Length and Porosity on the Acoustic Performance of Concentric Tube Resonators David Neihguk *1, and Abhinav Prasad 1 1 Mahindra Research Valley, Mahindra & Mahindra Ltd. *Corresponding author:
More information