Use. Worth noting. Key figures. Installation. lindab fasadium

Size: px
Start display at page:

Download "Use. Worth noting. Key figures. Installation. lindab fasadium"

Transcription

1 Contact, Overview, Index Guideline heating and cooling Plexus Professor / Professor Plus Premum / Premax / Solus Architect Polaris I & S Plafond Podium Celo Cabinett Capella Carat Atrium / Loggia Regula Drypac Lighting TEKNOsim Lindab Ventilation. All forms of reproduction without written permission are forbidden. is the registered trademark of Lindab AB. Lindab's products, systems, product and product group designations are protected by intellectual property rights (IPR).

2

3 Use Lindab's facade system is an efficient system designed to handle low air pressures. Typical environments where is used include, for example, schools, hospitals and offices. can be used for cooling, heating and ventilation. is supplied as standard with valves, flexible pipe connections and a connection card for the Regula Connect control system. Additional features that can be integrated into include, for example, Regula Combi and the Regula Secura condensation guard. Installation is placed along the facade, behind built-in window sills. is available both as a standard model and as a low model for use where space is critical. Worth noting is developed for an operating pressure of up to 0 Pa. utilises counter-flow heat exchange. The system is provided with a service hatch, which provides full access to the whole battery and helps maintain good hygiene. Lindab's facade system has been tested at the Technical Research Institute of Sweden (SP). Key figures Width: Height: Depth: Capacity: 00, 00, 00, 000, 00, 00 mm 00-0 mm 0 mm 0 W Calculation setup Room temp: C, Water temp: - C, Air temp: C, Nozzle air pressure: 0 Pa, Air flow: 0 l/s 0

4 0 Function is a facade system with a heating, cooling and ventilation functions. For installation there are supplementary parts for heating, cooling and ventilation (see under System Accessories). uses the supply air's driving power, which through induction creates a flow of air through the battery, thereby ejecting cooled or heated air from the system (see picture ). On the water side, the individual room temperature is controlled by an electronic control system, Regula Combi, with the heating and cooling in sequence. The control feature ensures that the heating and cooling are not activated at the same time. provides high cooling effects at operating pressures of 00 to 0 Pa. has been tested according to the V method at the Technical Research Institute of Sweden. Additional functions include a condensation guard, Regula Secura, which prevents condensation formation, and a service hatch that provides the maximum accessibility to the battery for cleaning and inspection. Design 's technical design provides the maximum output. The heating and cooling battery is installed to ensure counter-flow heat exchange between the incoming room air and the cooling water in the battery. Induction nozzles Cooling and heating battery Cooled/heated air Room air This technical solution provides high cooling effects, while allowing the supply cooling water temperature to be kept low, without condensation problems. 's end plates, sides and air duct are made from galvanized sheet steel. A service hatch is located on the front edge of the system. All of the heating and cooling battery is accessible for cleaning from both sides through this service hatch. When open, it also provides access to all the ventilation duct's intake nozzles. The battery has separate circuits for cooling and heating water. The circuits are made from copper pipe that has been expanded mechanically to ensure contact with the aluminium ribs. The battery is mounted horizontally and is easily accessible for cleaning. The water circuits are pressure-tested along their entire length to. MPa for pressure class NT 0. The cooling feed pipe is insulated against condensation. To protect the system further against condensation, a condensation guard can be installed. The condensation guard provides significantly increased security against condensation. The Regula Secura condensation guard is positioned next to the battery to detect the formation of moisture. If condensation does form, the cooling water circuit valve closes to prevent it. Then, it re-opens to detect what output can be achieved without condensation forming. The water pipes are made of copper. Nevertheless, the water should be oxygen-free to prevent corrosion. Regula Connect Basic Heating and cooling pipes Control valve and actuator Ventilation air Picture. uses the supply air's driving power, which through induction creates an air flow through the battery, thereby ejecting cooled or heated air from the system. 0

5 Hygiene is designed for easy cleaning and service. The service hatch provides unrestricted access to the system's battery both from above and below. On delivery, the system's battery is shielded with protective wrapping and the outlet with protective tape. This prevents dust and dirt from getting into the system before it is put into operation. Picture. Cleaning is easy with the service hatch on the front. Picture. installed without columns. Initial settings The facade system is supplied with the ordered airflow at a given air pressure. On-site adjustment is therefore not required. The Kv value of the control valves is preset at the factory (standard). If necessary, the airflow and pressure drop on the water side can also be adjusted on site. Picture. installed with columns. 0

6 Casing suggestions Lindab supplies the facade system without casing. Below are suggestions for three types of casing with different types of wood. When is installed with columns, the whole system is moved away from the facade so the piping and trunking pass in front of the column, see figure and. 0 Standard Low 0 Electrical cable duct Electrical cable duct Water pipes Water pipes Air duct Ø00 Ø0 Ø00 Air duct Ø00 Ø0 Ø00 0 Min. 0 mm 0 0 Measurements for standard and low facade systems, with a view to adjusting the casing. Min. 0 mm 0 0 Floor Figure. Figure. Picture. Casing with a worktop fitted with a hatch that is lifted to provide access. Picture. Casing with fixed worktop and detachable hatch on front side. Picture. Casing with fixed worktop and visible electrical cable duct.

7 Control system The room temperature control system with its pre-fabricated cabling is easy to adapt to varying room sizes and to changes in the room divisions. Operating voltage V AC (see picture ). Actuators: Delivered as Normally Closed. Normally Open actuators available on request. Time for opening and closing: approx. min. Regula Connect Basic: Connection card with connectors for mains cables, thermostat cables and terminal blocks for actuator cables. The card has alternatives for the mains cable outputs, so the control signal can be transmitted to the next system in both directions or terminated at a wall. A transformer is also connected to a free port. The connection card can be accessed by lifting the system grill (applies for standard systems). Cabling: The system consists of a device cable, extension cable and thermostat cable. The cables are prefabricated and equipped with error-proof connectors (sold separately). Regula Combi: Regula Combi is a zone controller for integrated installation in products or directly on the wall. Regula Combi has a built-in temperature sensor and can use input from presence sensor, CO sensor, condensation detector and an external temperature sensor. Transformer: primary 0V, secondary V AC. Regula Secura: The Regula Secura condensation guard cuts the power to the actuator if condensation is detected (plus feature). For more information about the control systems, refer to chapter Regula. Versions Standard systems Lengths: 00, 00, 00, 000, 00 and 00 mm. Depth: mm Duct diameter: 0 mm Height: 00 mm, with room for electrical ducting, exclusive of worktop Options Duct diameter: 00 mm Height: 0 mm Duct diameter: 00 mm Height: 0 mm Low model Duct diameter: Height: Duct diameter: Height: Duct diameter: Height: Switching over control cables REGULA CONNECT BASIC 00 mm 00 mm 0 mm 0 mm 00 mm 00 mm When moving, building new or removing existing partitions, the control system can be reconnected (see picture ). This is to allow the control centre to regulate the products in the room where it is installed. The device cable consists of four conductors, two for the supply voltage and two for the control signal to the heating and cooling actuators. The figures refer to the picture below. Connectors for heating output devices, such as heating circuit actuators. Connectors for cooling output devices, such as cooling circuit actuators. Connector for power and communication input from Regula Combi. - Connector for power and communication link between one or more beams. Connector for direct power via external transformer. 0 REGULA CONNECT BASIC N = Neutral L = Load S = Signal Heating out - S Heating out - N Heating out - L Cooling out - S Cooling out - N Cooling out - L Heating in - S Cooling in - S Supply out - N Supply out - L Heating link_s Cooling link_s Supply link - N Supply link - L Heating link_s Cooling link_s Supply link - N Supply link - L Supply in - N Supply in - V - L LINDAB REGULA CONNECT BASIC N = Neutral L = Load S = Signal Heating out - S Heating out - N Heating out - L Cooling out - S Cooling out - N Cooling out - L Heating in - S Cooling in - S Supply out - N Supply out - L Heating link_s Cooling link_s Supply link - N Supply link - L Heating link_s Cooling link_s Supply link - N Supply link - L Supply in - N Supply in - V - L LINDAB REGULA CONNECT BASIC N = Neutral L = Load S = Signal Heating out - S Heating out - N Heating out - L Cooling out - S Cooling out - N Cooling out - L Heating in - S Cooling in - S Supply out - N Supply out - L Heating link_s Cooling link_s Supply link - N Supply link - L Heating link_s Cooling link_s Supply link - N Supply link - L Supply in - N Supply in - V - L LINDAB REGULA CONNECT BASIC N = Neutral L = Load S = Signal Heating out - S Heating out - N Heating out - L Cooling out - S Cooling out - N Cooling out - L Heating in - S Cooling in - S Supply out - N Supply out - L Heating link_s Cooling link_s Supply link - N Supply link - L Heating link_s Cooling link_s Supply link - N Supply link - L Supply in - N Supply in - V - L LINDAB REGULA CONNECT BASIC N = Neutral L = Load S = Signal Heating out - S Heating out - N Heating out - L Cooling out - S Cooling out - N Cooling out - L Heating in - S Cooling in - S Supply out - N Supply out - L Heating link_s Cooling link_s Supply link - N Supply link - L Heating link_s Cooling link_s Supply link - N Supply link - L Supply in - N Supply in - V - L LINDAB REGULA CONNECT BASIC N = Neutral L = Load S = Signal Heating out - S Heating out - N Heating out - L Cooling out - S Cooling out - N Cooling out - L Heating in - S Cooling in - S Supply out - N Supply out - L Heating link_s Cooling link_s Supply link - N Supply link - L Heating link_s Cooling link_s Supply link - N Supply link - L Supply in - N Supply in - V - L LINDAB Picture. When existing partition walls are moved, the control system can be reconnected. Trafo H C H C H C H C H C H C Heating out - S Heating out - N Heating out - L Cooling out - S Cooling out - N Cooling out - L Heating in - S Cooling in - S Supply out - N Supply out - L Heating link_s Cooling link_s Supply link - N Supply link - L Heating link_s Cooling link_s Supply link - N Supply link - L Supply in - N Supply in - V - L LINDAB N = Neutral L = Load S = Signal

8 0 grills Galea is the name of Lindab's new grills for. The grills have arched ribs for the optimum air distribution. Galea is placed in the casings for and is made from aluminium. The grills are available in lengths from 00 to 00 mm. They are available in two colours, white-coated and natural-anodised. Designation Galea grill 00, nature Galea grill 00, nature Galea grill 00, nature Galea grill 000, nature Galea grill 00, nature Galea grill 00, nature Galea grill 00, white Galea grill 00, white Galea grill 00, white Galea grill 000, white Galea grill 00, white Galea grill 00, white Size dim: x mm dim: x mm dim: x mm dim: x mm dim: 0x mm dim: x mm dim: x mm dim: x mm dim: x mm dim: x mm dim: 0x mm dim: x mm

9 Dimensioning Cooling capacity air P a. Start by calculating the capacity required for the room, to keep a certain temperature. Lindab s TEKNOsim is an excellent tool for this.. Calculate which cooling capacity, or read in diagram, that is supplied by the ventilation air. Remaining cooling capacity needs to be cooled by the water circuit in. The formula for calculating the capacity of the air: P a = q ma x c pa x t ra Size comparison by t r = C with: q a = Primary air flow rate P. a [W] = q a [l/s] x. t ra [K] and P a [W] = q a [m³/h] x 0. t ra [K]. Definitions: P a = Cooling capacity air [W] P w = Cooling capacity water [W] P tot = Cooling capacity total [W] q ma = Air mass flow rate [kg/s] q a = Primary air flow rate [l/s] c pa = Specific heat capacity air [,00 kj/kg K] t r = Room air temperature [ C] t wi = Water inlet temperature [ C] t wo = Water outlet temperature [ C] t ra = Temp. diff., room air and primary air temp. [K] t rw = Temp. diff., room air and mean water temp. [K] t w = Temp. diff. water circuit [K] e tw = Capacity correction for temperature e qw = Capacity correction for water flow P Lt = Specific cooling capacity [W/(m K)] 0 [W] P a [W] Luftens Cooling kyleffekt capacity air P a P = = q a qx p x., x x t ra t t ra [K] Primary air flow Luftflöde rate q a [l/s] Diagram. Cooling capacity air P a as function of the primary air flow rate q a. If the air supply flow is l/s and the temperature difference of the room air and the supply air is t ra = K, then the Cooling capacity air of the air is 0 W.

10 0 Dimensioning Cooling capacity water P w Follow the instructions below to read off the effect from the diagram.. Calculate t rw (room average water). Product length L minus 0. m, to obtain the active length L act.. Divide the airflow q a by the active length L act. Enter the result on the lower axis of diagram.. Follow the flow line to the right pressure, and then read off the specific cooling capacity P Lt per active metre.. Multiply the specific cooling capacity that was read off by t rw and active length L act. P Lt Lt [W/(m K)] Specific Cooling Capacity Example Cooling: What is the cooling capacity of 000 with l/s and pressure of 0 Pa? The room's summer temperature is assumed to be.ºc. The cooling water temperature in/out of is /ºC. Answer: Temperature difference: t rw = t r (t wi + t wo )/ t rw =. - (+) / = K Active length: L act =.0 m - 0. m = 0. m q a / L act = l/s / 0. m =. l/(s m) Read off, from diagram : P Lt = 0. W/(m K) Cooling capacity: P w = 0. W/(m K) K 0. m = W 0 Pa 0 Pa 00 Pa 0 Pa Pa /metre qq a a // L act act [l/(s m)] Diagram. Specific cooling capacity P Lt as a function of airflow per active metre at nozzle pressures of 00, 0, 0, 00 and 0 Pa.

11 Minimum airflow at different pressures System size Pressure (Pa) Table. Minimum airflow at different pressures for the air from to reach the ceiling with a room height of.0 m. Temperature difference t between mean water and room is 0 C. Heating natural convection System size t Table. The system's heat emission through natural convection in W (no supply air) for respective sizes and temperature difference between the room temperature and the mean temperature of the heating water. 0

12 heating effect sound Effect according to the V method The tabulated data for the cooling effect is measured according to the V method at the Technical Research Institute of Sweden. The test measurements are made on the 00 system at 00 Pa, 0 Pa and 0 Pa, with casing and grill mounted on the system. Operating pressure at 00 Pa (0- l/s) The V method means that the room temperature is measured at. m above floor, i.e. the temperature in the occupied area. The V method gives a lower effect value compared to conventional measurements. This is because conventional measurement methods use the temperature of inlet air to the facade system to calculate the effect values. Inlet air has a lower temperature than that in the occupied area. 0 * Room height should be less than. m. 0* 00 < 0* < 00 < * < * 00 < 00 0 < 00 0 < * < < < * < Table -. Table -. The systems' cooling and heating effect in W, at an operating pressure of 00 Pa, an airflow of 0 to l/s and different t. The system's noise sound generation in L A db(a) for a system with casing in a room with 0 m Sabine equivalent sound absorption area.

13 heating effect sound Operating pressure at 00 Pa (-0 l/s) * Room height should be less than. m. 00 < < * < < < < * 00 0 < < < < Table -. The systems' cooling and heating effect in W, at an operating pressure of 00 Pa, an airflow of to 0 l/s and different t System's inherent noise generation in L A db(a) for a system with casing in a room with 0 m Sabine equivalent sound absorption area. 0

14 0 heating effect sound Operating pressure 0 Pa (0- l/s) * Room height should be less than. m < 0* 00 < 0* < 00 0 < 00 0 < * 00 < * < < < < * < 00 0 < 00 < 000 < * < Table -. The systems' cooling and heating effect in W, at an operating pressure of 0 Pa, airflow of 0 to l/s and different t The system's inherent noise generation in L A db(a) for a system with casing in a room with 0 m Sabine equivalent sound absorption area. 0

15 heating effect sound Operating pressure 0 Pa (-0 l/s) * Room height should be less than. m. Table -0. The systems' cooling and heating effect in W, at an operating pressure of 0 Pa, airflow of to 0 l/s and different t. The system's inherent noise generation in L A db(a) for a system with casing in a room with 0 m Sabine equivalent sound absorption area < 000 < 00 < < 00 0 < < < < < < < 0* 00 < < 0

16 0 heating effect sound Operating pressure at 0 Pa (0- l/s) * Room height should be less than. m < < 0* 00 < 0* < 00 < < < * < * < < < 00 0 < < * < < 00 < < < Table -. The systems' cooling and heating effect in W, at an operating pressure of 0 Pa, airflow of 0 to l/s and different t. The system's inherent noise generation in L A db(a) for a system with casing in a room with 0 m Sabine equivalent sound absorption area.

17 heating effect sound Operating pressure at 0 Pa (-0 l/s) < < < 00 0 < * 00 0 < < < < 0* < < < < 0 00 < < < Table -. Systems' cooling and heating effect in W at operating pressure of 0 Pa, air flow of to 0 l/s and different t. The system's inherent sound generation in L A db(a) for a system with casing in a room with 0 m Sabine equivalent sound absorption area. 0

18 0 heating effect sound Operating pressure 00 Pa (0- l/s) < 00 0 < < 000 < * < 00 0 < < < < < 0 00 < < < 0* < 00 < < < < < * 00 0 < Table 0-. The systems' cooling and heating effect in W, at an operating pressure of 00 Pa, airflow of 0 to l/s and different t. The system's inherent noise generation in L A db(a) for a system with casing in a room with 0 m Sabine equivalent sound absorption area.

19 heating effect sound Operating pressure 00 Pa (-0 l/s) < < < 00 0 < < < 0 00 < < < < < 000 < 00 < < < < < Table -. The systems' cooling and heating effect in W, at an operating pressure of 00 Pa, airflow of to 0 l/s and different t. The system's inherent noise generation in L A db(a) for a system with casing in a room with 0 m Sabine equivalent sound absorption area. 0

20 heating effect sound Operating pressure 00 Pa (0 l/s) < < Table. The systems' cooling and heating effect in W, at an operating pressure of 00 Pa, airflow of 0 l/s and different t. The system's inherent noise generation in L A db(a) for a system with casing in a room with 0 m² Sabine equivalent sound absorption area. 0

21 pressure Example : What is the sound pressure in the first system of several systems connected in series? The airflow to the first unit is 00 l/s. The duct diameter (Ø) is 0. Answer: Read off the sound pressure from diagram, Inherent noise generation in the first system. The value is db(a). Add the value to the system's sound pressure - db(a). Read off the increase from diagram, Logarithmic addition of two s, and add it to give a higher sound pressure. Diagram shows a value of approx.. db(a), which must be added to the higher, db(a). Round off to a whole db(a) value. The result is a total sound pressure of db(a). [db(a)] Ljudtrycksnivå pressure Ø Ø Totalflöde flow [l/s] Diagram. Inherent noise generation in the first system. pressure with 0 m² Sabine attenuation. pressure 0 [db] Ökning Increase som to skall be adderas added till to den the högre higher nivån,0,,0,,0 0, Difference Skillnad between mellan the nivåer s som to skall be adderas added [db] Diagram. Logarithmic addition of two s.

22 0 Internal sound dampening Frequency (Hz) Size Table. Total sound power reduction from connecting duct to the room, including end reflection. Weight and water volume Weight, kg Ø00 duct Weight, kg Ø0 duct Weight, kg/m Ø00 duct Water content, cooling, l/m Water content, heating, l/m Copper pipes, quality 00 Table 0. Weight and water volume EN - CU-DHP EN - CU-DHP EN - CU-DHP EN - CU-DHP EN - CU-DHP EN - CU-DHP Pressure class PN0 PN0 PN0 PN0 PN0 PN0

23 TTV valve KPa mbar mmws 0² 0³ ² 0³ 0 0² POSITIONS KVs m³/h Q m³/h Diagram. Valve settings for thermal actuators.

24 Pressure drop in water circuit, cooling has a factory-preset total pressure drop of kpa across the valve hoses and battery, at a nominal flow calculated on the basis of t (water in out ) K. (see table ). System length [mm] Nominal flow [l/s] Table., nominal flow. [l/s] Water Flödeflow 0.0 0, , , , , , ,0 Ø Ø , , ,0,.., 0 0 Minimum allowed flow of 0.0 l/s (Ø ) and 0.0 l/s (Ø0) Pressure Tryckfall Drop p w [kpa] Diagram. Pressure drop in the battery's cooling circuit. Example Cooling: 000, which provides an output of W. t w = K q w = P w / (c pw t w ) q w = / (00 x ) = 0.0 l/s The pressure drop in the water circuit in diagram is read off as Δp w =. kpa. Definitions: q w = Water flow rate [l/s] P w = Cooling capacity water [W] c pw = Specific heat capacity water [00 Ws/(kg K)] Δt w = Temperature difference water circuit [K] 0

25 Pressure drop in water circuit, heating has a factory-preset total pressure drop of kpa across the valve and battery, at a nominal flow calculated on the basis of t (water in out) 0 K. (see table ). System length [mm] Nominal flow [l/s] Table., nominal flow. [l/s] Water Flödeflow 0.0 0, , , , , , , , , ,0 Ø Ø , 0, , 0. 0, 0. 0, 0. 0,,. 0 Minimum allowed flow of 0.0 l/s (Ø ) and 0.0 l/s (Ø0) Pressure Tryckfall Drop p w [kpa] Diagram. Pressure drop in the battery's heating circuit 0 [l/s] Water flow 0.0 0, , , ,0 Heating Cooling 0.0 0, , ,.,., Pressure Drop p w [kpa] Diagram. Pressure drop in the flexible pipes. Heating at 0 C, cooling at C.

26 Dimensions Underside of board Underside of board Underside of board Unit length 00 mm Unit length 000 mm L- L L-0 L+ L- ø L-0 L+ ø0 ø00 0 L-0 L+ Dimensions of pipe bracket (accessory). Figure. standard, dimensions.

27 Dimensions 0 0 Underside of board 0 0 Underside of board 0 0 Underside of board Unit length 00 mm Unit length 000 mm L L ø L-0 L+ ø0 L- L-0 L+ Figure. low, system dimensions. ø00 L-0 L+

28 Distribution diagrams, - 00 The measurements were conducted with cooled supply air ( t room air supply air C) and cooling in the water circuit ( t room mean water temperature 0 C). Measurements were made according to the V method. All heat supplied through the walls. Isos 0.0 m/s ca mm ca mm ca mm ca mm ca mm ca mm l/s l/s l/s l/s l/s l/s 0 00 mm 00 mm 00 mm 00 Pa 0 Pa 00 mm 00 mm 00 mm ca mm ca mm ca mm ca mm ca mm ca mm l/s l/s l/s l/s l/s l/s 00 mm 00 mm 00 mm 00 mm 00 mm 00 mm 00 Pa 0 Pa Figure. 00 distribution diagrams, different air and flow settings.

29 Distribution diagrams, 00 The measurements were conducted with cooled supply air ( t room air supply air C) and cooling in the water circuit ( t room mean water temperature 0 C). Measurements were made according to the V method. All heat supplied through the walls. Isos 0.0 m/s ca mm ca mm ca mm ca mm ca mm ca mm l/s l/s 0 l/s l/s l/s l/s 00 mm 00 mm 00 mm 00 mm 00 mm 00 mm 00 Pa 0 Pa 0 ca mm ca mm ca mm l/s l/s l/s 00 mm 00 mm 00 mm 00 Pa 00 mm Figure. 00 distribution diagrams, different air and flow settings.

30 0 Specification System: Length, [mm]: 00, 00, 00, 000, 00, 00 Duct dimension, [mm]: Ø00, Ø0, Ø00 Height, [mm]: Standard 0 - Ø00, 00 - Ø0, 0 - Ø00 Low model 00 - Ø00, 0 - Ø0, 00 - Ø00 Air quantity, [l/s]: - 0 l/s Nozzle pressure, [Pa]: 00-0 Pa Plus features: Regula Secura Floor connection Only heating or cooling Indicate connection dimension System accessories: T pipe --: Indicate type and quantity T pipe --: Indicate type and quantity Termination pack with air bleed: Heating and cooling Heating or cooling Nipple Ø00, Ø0, Ø00 Indicate diameter and quantity Windowsill grill/straight flow: Indicate system size Windowsill grill/angled flow: Indicate system size Windowsill grill Galea with arched ribs: Indicate system size Control equipment: Regula Combi, Thermostat cable Transformer F 0 VA (Max. systems) Transformer F VA (Max. systems) Order code Product Type: Product length: 00, 00, 00, 000, 00, 00 Height: Standard, Low Air connection: 00, 0, 00 Static nozzle pressure (Pa): Air volume (l/s): Programme text from Lindab Qty Product: Air quantity: 0 l/s Air pressure: 0 Pa Plus features: Regula Secura condensation guard: Accessories: Regula Combi: 0 Thermostat cable: 0 Extension cables: 0 Pipe bracket: 0 Termination pack, incl. air bleed: 0 Galea grill 000 white: 0

Worth noting. Introduction. Key figures. lindab architect. Picture 1. Architect Circum, Luna and Prisma.

Worth noting. Introduction. Key figures. lindab architect. Picture 1. Architect Circum, Luna and Prisma. Contact, Overview, Index Guideline heating and cooling Plexus Professor / Professor Plus Premum / Premax / Solus Architect Polaris I & S Plafond Podium Celo Cabinett Capella Carat Fasadium Atrium / Loggia

More information

Supply air beam. Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor / Professor Plus. Premum / Premax / Solus.

Supply air beam. Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor / Professor Plus. Premum / Premax / Solus. Contact, Overview, Index Guideline heating and cooling Plexus Professor / Professor Plus Premum / Premax / Architect Polaris I & S Plafond Podium Celo Cabinett Capella Carat Fasadium Atrium / Loggia Regula

More information

Supply air beam. Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor / Professor Plus. Premum / Premax / Solus.

Supply air beam. Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor / Professor Plus. Premum / Premax / Solus. Contact, Overview, Index Guideline heating and cooling Plexus Professor / Professor Plus Premum / / Solus Architect Polaris I & S Plafond Podium Celo Cabinett Capella Carat Fasadium Atrium / Loggia Regula

More information

Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor. Pilot. Architect. Polaris I & S. Plafond. Podium. Celo. Cabinett.

Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor. Pilot. Architect. Polaris I & S. Plafond. Podium. Celo. Cabinett. & S Contact, Overview, Index Guideline heating and cooling Plexus Professor Pilot Architect & S Plafond Podium Celo Cabinett Capella Carat Fasadium Atrium H & C /Loggia Regula Drypac Lighting TEKNOsim

More information

Nozzles. About Lindab. Comfort and Design. Product overview / symbols. Theory. Ceiling diffusers. Ceiling diffusers - visible.

Nozzles. About Lindab. Comfort and Design. Product overview / symbols. Theory. Ceiling diffusers. Ceiling diffusers - visible. Nozzles About Lindab Comfort and Design Product overview / symbols Theory Ceiling diffusers Ceiling diffusers - visible Plenum boxes Wall diffusers Nozzles Ventiduct Grilles Displacement diffusers VAV

More information

Dimensions. Order code. Materials and finish. lindab ceiling diffusers

Dimensions. Order code. Materials and finish. lindab ceiling diffusers LKP Description LCP is a flush-mounted square diffuser with a circular unperforated face plate for installation in ceiling systems. LCP can be used for both supply and exhaust air. LCP is suitable for

More information

Plain diffuser. Dimensions

Plain diffuser. Dimensions Dimensions Ø U Ød B C Ø E Ø A Description is a circular diffuser with an unperforated adjustable face plate and can be used for both supply and extract air. The diffuser can be switched between horizontal

More information

Variable swirl diffusers

Variable swirl diffusers Swirl diffusers, Variable swirl diffuser OD- Application Diffuser is designed for air conditioning of rooms with floor to ceiling highs of to 0 m and high induction requirements. It is suitable for large

More information

Nozzle diffuser. Dimensions

Nozzle diffuser. Dimensions Dimensions ØU Ød H 0 ØA Description is a circular diffuser with individually adjustable nozzles. The diffuser is suitable for the horizontal supply of cooled air, where great flexibility in the dispersal

More information

VK2 volume flow controller Overview

VK2 volume flow controller Overview New option with sound attenuator Maintenance-free VK2 volume flow controller that operates without an auxiliary power supply, for ventilation and air conditioning systems. Adjustable on site. Outstanding

More information

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS Variable or constant flow regulation or constant pressure regulation Wireless communication via radio Integrated sensor

More information

Plain diffuser. Dimensions

Plain diffuser. Dimensions Dimensions ØU Ød 22 37 ØD Description is a circular diffuser with unperforated face plate and can be used for both supply and extract air. is suitable for horizontal supply of cooled air where a high impulse

More information

Nozzle diffuser. Dimensions

Nozzle diffuser. Dimensions Nozzle diffuser GTI Dimensions Installation Ød Description GTI is a flexible supply air nozzle that is suitable for ventilation of large areas. The nozzle can be used for both heated and cooled air and

More information

Air distribution systems. Jet nozzle DW-N2... Swivel jet nozzle DW-V2... Twist nozzle DW-V2-...-DR

Air distribution systems. Jet nozzle DW-N2... Swivel jet nozzle DW-V2... Twist nozzle DW-V2-...-DR Air distribution systems Jet nozzle DW-N... Swivel jet nozzle DW-V... Twist nozzle DW-V-...-DR DS E 01. Jet nozzle and twist nozzle Preliminary remarks Jet nozzle DW N Swivel jet nozzle DW V Twist nozzle

More information

Grille. Min. - max. dimensions

Grille. Min. - max. dimensions Min. - max. dimensions H L 0 00 75 00 Standard grilles are available with mm pitch within the above min. and max. sizes. Customized sizes available on request. Description is an adjustable single or double

More information

Multi-cone diffuser. Dimensions. Description FKD is an adjustable circular multi-cone diffuser, which is typically used for supply air.

Multi-cone diffuser. Dimensions. Description FKD is an adjustable circular multi-cone diffuser, which is typically used for supply air. Dimensions Vertical Ø N D F G Ø A Ø B C Horizontal Description is an adjustable circular multi-cone diffuser, which is typically used for supply air. The diffuser can be switched between horizontal and

More information

Siv-inn School. Complete air-supply solution for school premises. Ensures excellent air supply Cleanable Reinforced front Ideal for renovation work

Siv-inn School. Complete air-supply solution for school premises. Ensures excellent air supply Cleanable Reinforced front Ideal for renovation work GB0702 11.15 Complete air-supply solution for school premises Ensures excellent air supply Cleanable Reinforced front Ideal for renovation work TROX Trox Norge AS PO Box NO-2712 Brandbu Telefon +47 61

More information

Krantz Components. Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems

Krantz Components. Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems DS E 01. with guide ring or jet straightener Preliminary remarks The variable twist outlet with guide ring

More information

Air distribution systems. Radial outlet RA-N2...

Air distribution systems. Radial outlet RA-N2... Air distribution systems Radial outlet RA-N... DS E 0.01 Radial outlet RA-N Preliminary remark KRANTZ KOMPONENTEN radial outlets RA-N have fixed radial vanes and are available with circular or square face.

More information

Air distribution systems. Linear whirl outlet WL...

Air distribution systems. Linear whirl outlet WL... Air distribution systems Linear whirl outlet WL... DS 0 E 1.013 Preliminary remarks Mode of operation The linear whirl outlet generates turbulent mixing ventilation. It can be installed on or in a wall

More information

Multi-cone diffuser. Dimensions

Multi-cone diffuser. Dimensions Dimensions Vertical Ød 8 Max. H ØU ØD Horizontal Ød Description is an adjustable circular multi-cone diffuser, which is typically used for supply air. The diffuser can be switched between horizontal and

More information

Slot diffusers. Slot diffusers, Round duct diffusers. Slot diffusers. Slot diffusers LD-13, LD-14

Slot diffusers. Slot diffusers, Round duct diffusers. Slot diffusers. Slot diffusers LD-13, LD-14 , Round duct diffusers D-, D- Application D- and D- slot diffusers are designed for the supply of air in rooms with floor to ceiling heights of.5 to m for supplying either cold or warm air, in particular

More information

GRC. Circular egg crate grille for transfer/extract air and wall/ceiling mounting QUICK FACTS

GRC. Circular egg crate grille for transfer/extract air and wall/ceiling mounting QUICK FACTS Circular egg crate grille for transfer/extract air and wall/ceiling mounting QUICK FACTS For exhaust air 91% free area Handles large airflows Cleanable Can be used with commissioning box ALS Standard colour

More information

Linear ceiling diffuser

Linear ceiling diffuser L-0--01e Linear ceiling diffuser Type LDD / LDDL Contents Realisation Application Safety instructions Contents Realisation Application Safety instructions Dimensions 3 Dimensions Installation Quick selection

More information

Supply air nozzle. Dimensions. DAD-0 With flange for mounting on a wall or duct side.

Supply air nozzle. Dimensions. DAD-0 With flange for mounting on a wall or duct side. A imensions A-0 With flange for mounting on a wall or duct side. Ø ( ) 0 Ø F Ø Nom 0 0 Ø A Ø B Ø E escription A is an adjustable supply air nozzle suitable for ventilation of large areas where long throws

More information

Krantz Components. Twist outlet DD-N... for ceiling installation. Air distribution systems

Krantz Components. Twist outlet DD-N... for ceiling installation. Air distribution systems Krantz Components Twist outlet DD-N... for ceiling installation Air distribution systems DS E 0. Twist outlet Preliminary remarks and construction design Preliminary remarks Twist outlets for ceiling installation

More information

Krantz. Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems

Krantz. Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems Krantz Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems DS E 01.18 Variable twist outlet with guide ring or jet straightener Preliminary remarks The variable

More information

Krantz. RL-C2 radial slot outlet. Air distribution systems

Krantz. RL-C2 radial slot outlet. Air distribution systems RL-C2 radial slot outlet Air distribution systems DS E 04.1 Introduction The RL-C2 radial slot outlet with circular face generates a turbulent mixed flow. It is used for supply and return air distribution

More information

Air distribution systems. Adjustable induction outlet IN-V...

Air distribution systems. Adjustable induction outlet IN-V... ir distribution systems djustable induction outlet IN-V... DS E 0. Construction and function Preliminary remarks In addition to its induction outlet with preset discharge direction ), KRNTZ KOMPONENTEN

More information

variable flow dampers

variable flow dampers Constant-/ DAU, DAEU, DAVU Summary DAU - manual single flow unit DAEU - motorized twin flow unit DAVU - motorized variable flow unit Diameters Ø 0 Flow range 0 l/s ( m³/h) Pressure range Pa (over the unit)

More information

SWIFT Ceiling. Square ceiling air diffuser for supply air QUICK FACTS

SWIFT Ceiling. Square ceiling air diffuser for supply air QUICK FACTS Square ceiling air diffuser for supply air QUICK FACTS Flush design Also available in a version for extract air. Designed for modular suspended ceilings (600 x 600 mm) Quick Access Adapter for systemized

More information

ALC. ALBATROSS Supply air terminal for large airflows

ALC. ALBATROSS Supply air terminal for large airflows ALBATROSS Supply air terminal for large airflows Quick facts Large airflows Suitable for cooling or heating Manual or motorised adjustment Pressure drop independent of selected spread pattern Can be used

More information

Circular duct grille

Circular duct grille Dimensions B+0 A+0 A B Description is a rectangular ventilation grille with vertical adjustable bars for direct installation in circular ducts. The grille can be used for both supply and exhaust air. The

More information

SWIFTTM. Ceiling. Square ceiling air diffuser for supply air

SWIFTTM. Ceiling. Square ceiling air diffuser for supply air SWIFTTM Ceiling SWIFT Ceiling Square ceiling air diffuser for supply air Quick facts Flush design Also available in a version for extract air. Designed for modular suspended ceilings (600 x 600 mm) Quick

More information

Air distribution systems. Adjustable radial outlet RA-V...

Air distribution systems. Adjustable radial outlet RA-V... Air distribution systems Adjustable radial outlet RA-V... DS E 0.2013 Construction design Preliminary remarks KRANTZ KOMPONENTEN has developed its wellknown, successful radial outlet into an adjustable

More information

Swirl Diffusers Type DLA 7 and DLA 8

Swirl Diffusers Type DLA 7 and DLA 8 LTG Incorporated Swirl Diffusers Type DLA 7 and DLA 8 LTG Incorporated 1 Corporate Drive, Suite D Spartanburg, SC 93 PO Box 889, Spartanburg, SC 9 USA Tel: 86-599-63 Fax: 86-599-63 e-mail: info@ltg-inc.net

More information

Hudevad P100. Technical datasheet

Hudevad P100. Technical datasheet Technical datasheet Key benefits Available in three depths Highly flexible in use Integrated top grille Harmonious and finished look Kundenedfal Low, streamlined design Ideal in front of glazing to prevent

More information

GTH. Rectangular double deflection grille QUICK FACTS

GTH. Rectangular double deflection grille QUICK FACTS Rectangular double deflection grille QUICK FACTS For supply air Adjustable air deflectors Cleanable Installed using mounting frames FHB / FHA or commissioning box TRG Available in alternative colours A

More information

Ascotherm eco KC281 Heating and cooling in 2-conductor system

Ascotherm eco KC281 Heating and cooling in 2-conductor system KC281 Heating and cooling in 2-conductor system Tender specification, range available and sizes Tender specification Version KC281 heating and cooling in 2-pipe system Ready-to-install floor pans for the

More information

NOP, NOT and NOX. Adaptable, flexible supply air diffusers with ultra low height for free installation. climecon.fi 07.16

NOP, NOT and NOX. Adaptable, flexible supply air diffusers with ultra low height for free installation. climecon.fi 07.16 NOP, NOT and NOX Adaptable, flexible supply air diffusers with ultra low height for free installation 07.16 NOP, NOT and NOX The most outstanding features of the NOP, NOT and NOX supply air diffusers are

More information

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement

More information

Connections Standard. Description

Connections Standard. Description Section Convectors Description Connections Standard without built-in valve or version with built-in valve Air vent, Drain Fixing Pressure versions, Fittings, Surface finishes, Special versions Heat output

More information

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS Square extract air diffuser QUICK FACTS Perforated air diffuser front face Manages large extract airflows Flush design Designed for modular suspended ceilings Quick Access front face Can be combined with

More information

Krantz. Radial slot outlet with square blade array RL-Q2... circular blade array RL-R2... Air distribution systems DS 4186 E 09.

Krantz. Radial slot outlet with square blade array RL-Q2... circular blade array RL-R2... Air distribution systems DS 4186 E 09. Krantz Radial slot outlet with square blade array RL-Q2... circular blade array RL-R2... Air distribution systems DS 86 E 09./1 with square and circular blade array Preliminary remark The radial slot outlet

More information

XHDU Cassette type fan-coils for double/four pipe connections 1,98-14 kw HYDRONIC TERMINALS

XHDU Cassette type fan-coils for double/four pipe connections 1,98-14 kw HYDRONIC TERMINALS HYDRONIC TERMINALS XHDU 402 1203 Versions XHDU 2T XHDU-R 2T XHDU 4T XHDE 2T Single coil for double pipe connections Single coil for double pipe connections with heater Double coil for four pipe connections

More information

KZMb

KZMb -------------------------------------------------------- Electronic zone controller for pressure regulation ---------------------------------------------------------------------- FUNCTION KZM is an electronic

More information

CDD/CDR. Circular ceiling diffuser for supply air QUICK FACTS

CDD/CDR. Circular ceiling diffuser for supply air QUICK FACTS Circular ceiling diffuser for supply air QUICK FACTS Spread pattern can be shielded Used with commissioning box ALS Cleanable Adjustable slot Perforated diffuser face = CDD Non-perforated diffuser face

More information

ALUMINIUM CENTRIFUGAL FANS. 4 x M6 x OUTLET x M6 x 20

ALUMINIUM CENTRIFUGAL FANS. 4 x M6 x OUTLET x M6 x 20 DESCRIPTION Dutair LK-series industrial ventilators consist of a robust body made from die-cast aluminium alloy. Impellers are made of extruded aluminium. The asynchronous electric motors are maintenance

More information

ALUMINIUM CENTRIFUGAL FANS x M6 x x M6 x 16

ALUMINIUM CENTRIFUGAL FANS x M6 x x M6 x 16 LK4 DESCRIPTION Dutair LK-series industrial ventilators consist of a robust body made from die-cast aluminium alloy. Impellers are made of extruded aluminium. The asynchronous electric motors are maintenance

More information

Swirl diffusers, Variable swirl diffusers

Swirl diffusers, Variable swirl diffusers 0 Variable swirl diffusers SLOT IFFUSERS, ROUN UCT IFFUSERS SWIRL IFFUSERS, VARIABLE SWIRL IFFUSERS CIRCULAR IFFUSERS, SQUARE IFFUSERS VENTILATING GRILLES, VENTILATING VALVES, Variable swirl diffusers

More information

KZPb

KZPb ---------------------------------------------------------- ---------------------------------------------------------------------- Electronic constant pressure regulator FUNCTION KZP is an electronic pressure

More information

Cooling Water Flow Regulator

Cooling Water Flow Regulator Temperature controlled, indirectly and directly actuated diaphragm valves / seat valves Port size G 3/8 to G DN 0 to DN 0 ontinuous regulation High accuracy No auxiliary energy required Technical data

More information

THE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP

THE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP I N V E RT E R ion Range exible Combine Modular TDV I TDV I TDV I INVERTER INVERTER INVERTER 14, 16, 18, 20, 22 HP TDV I 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP INVERTER INVERTER INVERTER TDV I INVERTER

More information

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air Ceiling Square ceiling air diffuser for supply air and extract air Quick facts Flexible distribution pattern, yet the acoustic data remains the same One K-factor regardless of distribution pattern Designed

More information

Operating Instructions for Digital Manometer. Model: MAN-SD

Operating Instructions for Digital Manometer. Model: MAN-SD Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5

More information

CDD/CDR. Single cone ceiling diffusers for supply air. Quick facts. Quick guide CDD/CDR A I R F L O W - S O U N D L E V E L

CDD/CDR. Single cone ceiling diffusers for supply air. Quick facts. Quick guide CDD/CDR A I R F L O W - S O U N D L E V E L Single cone ceiling diffusers for supply air Quick facts Spread pattern can be shielded Used with commissioning box ALS Cleanable Adjustable slot Perforated diffuser face = CDD Imperforated diffuser face

More information

series FLOOR

series FLOOR series FLOOR www.koolair.com Floor Series 3 DSA, DSA-PR, DSA-HV and DF-CP-MT Floor swirl diffusers CONTENTS DSA / DSA-PR / DSA-HV diffusers 4 Models and dimensions 5 DSA Selection tables 6 DSA Selection

More information

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS Square ceiling air diffuser for supply air and extract air QUICK FACTS Flexible distribution pattern, yet the acoustic data remains the same One K-factor regardless of distribution pattern Designed for

More information

Swirl diffusers, Variable swirl diffusers Swirl diffusers

Swirl diffusers, Variable swirl diffusers Swirl diffusers IMP Klima, Variable swirl diffusers Swirl diffuser OD- Fixed grille For air supply or exhaust Recommended temperature difference between supplied and internal air in the room is between 0 to 0 K Low static

More information

PET PETI PET/PETI. Supply air diffuser for ceilings

PET PETI PET/PETI. Supply air diffuser for ceilings Supply air diffuser for ceilings PET PETI The TR connection box is an optional accessory for PET and PETI. Description The square perforated ceiling diffuser is best suitable for cofort ventilation. The

More information

VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems

VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems 06 EN - Straight valves VDN.. Angle valves VEN.. Reverse angle valves VUN.. ACVATIX TM Radiator valves NF norm, for -pipe heating systems VDN.. VEN.. VUN.. Valve bodies made of brass, mat nickel-plated

More information

PHOS 15 LED PROJECTOR

PHOS 15 LED PROJECTOR PHOS 15 LED PROJECTOR SPECIFICATIONS Item:.. PHOS 15 Body:.... Aluminium Available Colours:... White / Black / Silver Weight:.... 1.9 kg On / Off Switch:..... Not Available Environmental Conditions:.....

More information

Ceiling Diffuser. Type ADLR with circular face. Type ADLR-Q with square face 2/16/EN/8

Ceiling Diffuser. Type ADLR with circular face. Type ADLR-Q with square face 2/16/EN/8 2/16/EN/8 Ceiling Diffuser Type ADLR with circular face Type ADLR-Q with square face TROX GmbH Telephone +49/28 45/2 02-0 Telefax +49/28 45/2 02-2 65 Heinrich-Trox-Platz e-mail trox@trox.de D-47504 Neukirchen-Vluyn

More information

MR medium rating busbar

MR medium rating busbar technical information General features MR is fully compliant with S EN 0-, specifically, the rated current of the Zucchini busbar trunking systems is always rated at the average ambient temperature of

More information

Circular duct grille. Dimensions. Description. Maintenance The grille should be removed to gain access to the duct.

Circular duct grille. Dimensions. Description. Maintenance The grille should be removed to gain access to the duct. Dimensions B+0 A+0 A B Description RGS is a rectangular ventilation grille with vertical adjustable bars for direct installation in circular ducts. The grille can be used for both supply and exhaust air.

More information

VD1 CLC. Small Valves DIN-range with a higher k v -value

VD1 CLC. Small Valves DIN-range with a higher k v -value 0 EN - Small Valves DIN-range with a higher k v -value VD CLC Valve body made of brass, mat nickel-plated DN, DN 0 and DN Internally and externally threaded (Rp / R) conforming to ISO 7- Manual knob /

More information

AC axial fan. Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA

AC axial fan. Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8-0 Fax +9 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of registration)

More information

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS CADB/T-N Series

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS CADB/T-N Series FILTERS F7 Compact heat recovery unit with cross-flow heat exchanger in 9 sizes from 500 m 3 /h to 8.350 m 3 /h. The casing is made from aluminium profile frame with double skinned 25 mm steel panels with

More information

CIRCO. Sound-attenuating transfer unit QUICK FACTS

CIRCO. Sound-attenuating transfer unit QUICK FACTS Sound-attenuating transfer unit QUICK FACTS Supplied in pairs For the transfer of air through a wall Fits in a circular cut opening Simple to install Mounting frame integrated into the transfer diffuser

More information

industry hall : highbay luminaire NJ700 LED Project number : sample system Customer : Processed by : Siteco Light Consulting Date : 07/2013

industry hall : highbay luminaire NJ700 LED Project number : sample system Customer : Processed by : Siteco Light Consulting Date : 07/2013 industry hall Customer : Processed by : Siteco Light Consulting Project description: spatial geometry (L*W*H): 54,00m*21,00m*9m reflection values (C*W*F): 70*50*20 maintenance factor: 0,67 user surface

More information

ALUMINIUM CENTRIFUGAL FANS. 4 x M6 x 16

ALUMINIUM CENTRIFUGAL FANS. 4 x M6 x 16 DESCRIPTION Dutair BCT-series aluminium centrifugal fans with open die-cast aluminium impellers and forward curved blades are suitable for material transport and high pressure applications. The asynchronous

More information

ALUMINIUM CENTRIFUGAL FANS M20 4 x M5 x 10 INLET. 4 x M5 x 12

ALUMINIUM CENTRIFUGAL FANS M20 4 x M5 x 10 INLET. 4 x M5 x 12 BCT61 DESCRIPTION Dutair BCT-series aluminium centrifugal fans with open die-cast aluminium impellers and forward curved blades are suitable for material transport and high pressure applications. The asynchronous

More information

Addendum to ARI Standard , Air Terminals September 2002

Addendum to ARI Standard , Air Terminals September 2002 Addendum to ARI Standard 880-98, Air Terminals September 2002 The September 2002 Addendum to ARI Standard 880-98, Air Terminals, is comprised of only the shaded portions shown, which has been incorporated

More information

KSV. Slot diffusers. Ordering code. Description. Linear diffusers 1 / 16

KSV. Slot diffusers. Ordering code. Description. Linear diffusers 1 / 16 Linear diffusers 1 / 1 KSV Slot diffusers Ordering code Number of slots Diffuser Length (mm) KSV - 1... - 19 Description KSV is an air terminal element primarily designated for air supply. It is suitable

More information

Circular air volume controller RWOA

Circular air volume controller RWOA Circular air volume controller RWOA TECHNICAL DATA page 7 Circular air volume controller RWOA Circular air volume controller RWOA enables automatic airflow control. RWOA is suitable for use in systems

More information

Valve Supply and exhaust air

Valve Supply and exhaust air IRY Dimensions Description The valve is designed for installation at a wall or in a ceiling. It can be used for new-build and for replacement. Its smart grip function ensures an easy installation. Its

More information

FRB. Exposed passive chilled beam for suspended installation

FRB. Exposed passive chilled beam for suspended installation Exposed passive chilled beam for suspended installation QUICK FACTS FRB is a passive chilled beam for comfort cooling especially designed for visible/suspended installation in the room. High cooling capacity,

More information

10-year industry best core warranty. 2-year warranty on balance of unit.

10-year industry best core warranty. 2-year warranty on balance of unit. MODEL FEATURES MERV-8 filters Fully insulated case Large cores for high efficiency No condensate pan or drain required AHRI Certified Rainhood included Access door for easy maintenance and Cleaning Integral

More information

KSAb

KSAb --------------------------------------------------------- ---------------------------------------------------------------------- Electronic slave and constant flow regulator for air flow regulation FUNCTION

More information

Air Handling Unit. Konvent

Air Handling Unit. Konvent Air Handling Unit Konvent Unbeatable advantages Konvent at a glance Technical Details Mistral S control Product overview Dimensions Benefits for you! Gentle temperature control To protect buildings and

More information

EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS. FCP 2008 testing procedures FCP acoustical test method pag. 1

EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS. FCP 2008 testing procedures FCP acoustical test method pag. 1 EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS FCP 2008 testing procedures FCP acoustical test method pag. 1 CONTENTS 1 - PURPOSE... 3 2 - NORMATIVE REFERENCES... 3 3 - DEFINITIONS... 3 3.1

More information

CHAPTER 5 CONVECTIVE HEAT TRANSFER COEFFICIENT

CHAPTER 5 CONVECTIVE HEAT TRANSFER COEFFICIENT 62 CHAPTER 5 CONVECTIVE HEAT TRANSFER COEFFICIENT 5.1 INTRODUCTION The primary objective of this work is to investigate the convective heat transfer characteristics of silver/water nanofluid. In order

More information

zehnder stratos CS CS CS CSW CSW Product Overview Model Code (example)

zehnder stratos CS CS CS CSW CSW Product Overview Model Code (example) Product Overview Model Code (example) CS-15-19 Depth (cm) eight (cm) CS = Convector Stratos CS = Convector Stratos with rear dummy panel CS-..-10 CS-..-13 No. of panels: 2 No. of fins: 2 Depth: 98mm eight:

More information

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22) Ex-Floodlight PXLED (Ex-Zone 1, 2, 21 and 22) Lighting under harsh conditions The new modular LED floodlight series PXLED is suited for nearly every kind of lighting task in hazardous areas, including

More information

VRF Technical Data Book

VRF Technical Data Book VRF Technical Data Book DVM S for Euro_ET (R4A, Hz, HP) Model : Premium (Compact / Energy Efficiency) Type Standard Type History Version Modification Date Remark Ver. 1. Release DVM S (R4A, Hz, HP) for

More information

Industrial Air Diffuser Type DLD for Heating and Cooling

Industrial Air Diffuser Type DLD for Heating and Cooling LTG Incorporated Industrial Air Diffuser Type DLD for Heating and Cooling LTG Incorporated Corporate Drive, Suite E Spartanburg, SC 20 PO Box 288, Spartanburg, SC 20 USA Tel: 8--0 Fax: 8-- e-mail: info@ltg-inc.net

More information

ELMO-G Vacuum Pumps/Compressors, Range 2BH1, Three-Phase 50 Hz

ELMO-G Vacuum Pumps/Compressors, Range 2BH1, Three-Phase 50 Hz ELMO- Vacuum Pumps/Compressors, Range 2BH1, Three-Phase 50 Hz Selection diagram vacuum operation Selection diagram compressor operation The performance curves are valid for pumping air at 15 C at the inlet

More information

EX-EMERGENCY LIGHT FITTINGS

EX-EMERGENCY LIGHT FITTINGS EX-EMERGENCY LIGHT FITTINGS nllk 0...N 1-36 W Plastic version for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 N are conform to the requirements of the ATEX-Directive

More information

42C/V. Fan Coil Unit 42C/V

42C/V. Fan Coil Unit 42C/V 2/V Fan oil Unit 2/V arrier makes the world a better place to live by creating a comfortable, productive and healthy environment regardless of climate. It is our mission is to be customer s first choice

More information

BNA Series. PLENUM FAN with Backward Wheels

BNA Series. PLENUM FAN with Backward Wheels BNA Series PLENUM FAN with Backward Wheels BNA Series BNA Series Plenum Fans Backward wheels Kruger Plenum Fans are designed for air handling applications where the fan operates unhoused within a plenum.

More information

Impedance relay and protection assemblies

Impedance relay and protection assemblies RXZK 21H, 22H, 23H 509 006-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE970175) (SE970184) Features Micro-processor based impedance relay with R and X settings

More information

Multifunctional Thermostatic Circulation Valve MTCV

Multifunctional Thermostatic Circulation Valve MTCV Multifunctional Thermostatic Circulation Valve MTCV Introduction Fig. 1 Basic version - A Fig. * Self-acting version with automatic disinfection function - B * thermometer is an accessory Fig. 3 Version

More information

series KAT Acoustic air transfer units

series KAT Acoustic air transfer units series Acoustic air transfer units www.koolair.com 1 Acoustic Air Transfer Unit CONTENTS Acoustic Air Transfer Unit 2 Dimensions 3 Technical Data 5 Product Codes 7 2 Acoustic Air Transfer Unit - Description

More information

Wöhler DP 700 Leakage Tester

Wöhler DP 700 Leakage Tester LEAKAGE CLASS ACHIEVED? Wöhler DP 700 Leakage Tester The Measure of Technology Made in Germany COLOR DISPLAY EINFACHE BEDIENUNG Wöhler DP 700 Leakage Tester Just 3 entries to classify an air ductwork system

More information

Mechanical flow-rate controllers

Mechanical flow-rate controllers L D L D L D Mechanical flow-rate controller MRP-1 (Circular) Description With the circular air flow controllers with automated action, the air flow rate is controlled via an asymmetrical control flap pivoting

More information

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I I nllk / I x W x W x W x W x W Technical data Cooper Crouse-Hinds - all rights reserved nllk / nllk nllk / nllk nllk / Marking to //EC II G Ex na II T / II D td A IP T C EC Conformity Statement PTB ATEX

More information

HELLA. Linear slot diffuser. Ordering codes. HELLA - Linear diffuser. Linear Diffusers 1 / 18. Example of the ordering code HELLA B-0-0-AN

HELLA. Linear slot diffuser. Ordering codes. HELLA - Linear diffuser. Linear Diffusers 1 / 18. Example of the ordering code HELLA B-0-0-AN Linear Diffusers / 8 HELLA Linear slot diffuser Ordering codes HELLA - Linear diffuser HELLA - Number of slots... Diffuser length L (mm) ) Increment mm... Deflector colour Damper Diffuser construction

More information

SV-2, SV-1, AVS, AVSL, SI Grilles

SV-2, SV-1, AVS, AVSL, SI Grilles Grilles SV-2, SV-1, AVS, AVS-L TECHNICAL DATA - 2004 page 351 SV-2, SV-1, AVS, AVSL, SI Grilles SV-2 SV-1 47 (H-17) x (W-17) (H-12) x (W-12) AVS, SI AVSL S SV, AVS, AVSL and SI grilles are designed for

More information

DBS315 1-phase SIDE CHANNEL BLOWERS

DBS315 1-phase SIDE CHANNEL BLOWERS DBS15/ 1-phase DESCRIPTION Dutair blowers for pressure and vacuum are compact machines consisting of an electric motor with a built-on pump housing. The rotational speed of the impeller creates a high

More information