Damper - circular. Dimensions. Description. Ordering example. comfort vav

Size: px
Start display at page:

Download "Damper - circular. Dimensions. Description. Ordering example. comfort vav"

Transcription

1 Dimensions L D B C H Ød Description is a circular control and shut-off damper, which meets the air tightness requirements of DS class. The damper can be used for pressure or volume flow regulation with external control options (open, closed, min., max.) depending on the form of control/regulation. is available with a spring return motor, so the damper can be used as a smoke damper. The damper can be controlled by an FRU (as a VRU) or a PR regulator, by a CTS system or Regula Combi (with modulating signal) or as a slave for another damper (mechanical slave operation with the same damper position). When ordering, it is important to specify the form of control, and whether the damper motor must be prograable. All dampers are supplied with Belimo motors. Type overview B C D H L -0-RU/SU 0-0-RP/SP 0 - Type ø-ø ø-ø 0 (Standard) 0 (Standard) -RU NM-V NM-V -RP LMA-MF-F NMA-MF-F -SU LMA-SR-F NMA-SR-F -SP LMA-MF-F NMA-MF-F Type ø-ø ø-ø (Spring-return) (Spring-return) -RU LF-V AF-V -RP LF-MFT AF-MFT -SU LF-SR AF-SR -SP LF-MFT AF-MFT Ordering example Product a bbb c d Type Standard 0 Spring return Size Ød Form of control R: Regulator-controlled S: Parallel signal (modulating) Prograing U: Without prograing P: Prograable RU RP SU SP Used only with PR ( and FRU) and is preset to a VAV input signal: ± V, Has a prograable motor, is used together with PR and is preprograed for a VAV input signal: ± V. Has modulating output signal indicating damper position for mechanical control of a slave damper. Has a motor, which is controlled by modulating input signal (-V). Also has a modulating output signal indicating damper position. Has a prograble motor, which can be controlled by optional input signal (Standard modulating). Also has a modulating output signal indicating damper position for mechanical control of a slave damper. We reserve the right to make changes without prior notice

2 Damper - rectangular DJP Dimensions A B 0 Description DJP is a rectangular control and shut-off damper, which meets the requirements of DS class. DJP has opposing aerodynamic damper blades that are rotated via a lever device. The damper is supplied with an LS connection system for rectangular ducts. The damper can be used for pressure or volume flow regulation with external control options (open, closed, min., max.) depending on the form of control/ regulation. DJP is available with a spring return motor, so the damper can be used as a smoke damper. The damper can be controlled by an FRA (as a VRA) or a PR regulator, directly by a temperature sensor or CTS system ( V modulating) or as a slave for another damper (mechanical slave operation with the same damper position). When ordering, it is important to specify the form of control, and whether the damper motor must be prograable. All DJP dampers have Belimo motors installed. Ordering example Product DJP a bbb c d Type Standard 0 Spring return Size A (Width) B (Height) Form of control R: Regulator-controlled S: Slave or sensor-controlled Prograing U: Without prograing P: Prograable overview RU RP SU SP Type 0 DJP-RU NM-V AF-V DJP-RP NMA-MF AF-MFT DJP-SU NMA-SR AF-SR DJP-SP NMA-MF AF-MFT Used only with PR (and FRU) and is preset to a VAV input signal: ± V. Has a prograable motor, is used together with PR and is preprograed for a VAV input signal: ± V. Has a modulating output signal indicating damper position for mechanical control of a slave damper. Has a motor, which is controlled by a modulating input signal (- V). Also has a modulating output signal indicating damper position. Has a prograable motor, which can be controlled by an optional input signal (standard modulating). Also has a modulating output signal indicating damper position for mechanical control of a slave damper. We reserve the right to make changes without prior notice

3 Damper - rectangular DJP Frequency-related sound effect level DJP-m [L w] [db] Pressure difference [Pa] [db(a)] Centre frequency [Hz] [L Duct velocity w (A)] m/s 00 m/s 00 m/s 00 m/s 00 Correction of sound effect level for other damper sizes Area [m²] 0, 0, 0, 0, 0,,0,,0 db correction We reserve the right to make changes without prior notice

4 Pressure drop diagram and sound data for dimensioning. The solid curves indicate the total pressure drop over the damper as a function of the volume flow q and the blade angle. The broken curves indicate the A-weighted sound effect level Lw (A), in db to the duct. Example: Dimension: Ø Volume flow: l/s Pressure drop: Pa The following can be obtained from the diagram: Blade angle 0 Sound effect level db(a) Measuring method for sound: Sound data has been measured by the Swedish National Testing and Research Institute (SP) with reference to ISO and EN/ISO. Blade angle: 0 = open damper. 0 = closed damper. Ø Ø Ø Ø We reserve the right to make changes without prior notice

5 Ø 0 0 Ø Ø Ø Ø 0 0 Ø We reserve the right to make changes without prior notice

6 Sound data The following pages give sound effect levels for ducts (flow noise) with reference to ISO as a function of volume flow and pressure difference. The necessary minimum prepressure difference is 0 Pa for all sizes, equivalent to the pressure loss over VRU at nominal volume flow and with a fully open damper. Dimension Ød 00 0 Pressure drop [Pa] [m/s] [m/s] [m/s] Mean frequency [Hz] Mean frequency [Hz] Mean frequency [Hz] 0 k k k k 0 k k k k 0 k k k k Air volume / 0 Air volume / Air volume / 0 0 Air volume 0 / Air volume / Air volume Air volume / Air volume 0 / Air volume / Air volume / Air volume / 0 Air volume 0 / Air volume [l/s / 0 ] Air volume 0 / Air volume / Air volume / 00 Air volume 0 / 0 Air volume / Air volume 00 / 0 Air volume 0 / Air volume / 0 0 Air volume 0 / Air volume / 0 Air volume 0 / Air volume 0 Air volume 0 / Air volume 00 / We reserve the right to make changes without prior notice

variable flow dampers

variable flow dampers Constant-/ DAU, DAEU, DAVU Summary DAU - manual single flow unit DAEU - motorized twin flow unit DAVU - motorized variable flow unit Diameters Ø 0 Flow range 0 l/s ( m³/h) Pressure range Pa (over the unit)

More information

Multi-cone diffuser. Dimensions

Multi-cone diffuser. Dimensions Dimensions Vertical Ød 8 Max. H ØU ØD Horizontal Ød Description is an adjustable circular multi-cone diffuser, which is typically used for supply air. The diffuser can be switched between horizontal and

More information

Nozzle diffuser. Dimensions

Nozzle diffuser. Dimensions Dimensions ØU Ød H 0 ØA Description is a circular diffuser with individually adjustable nozzles. The diffuser is suitable for the horizontal supply of cooled air, where great flexibility in the dispersal

More information

Nozzles. About Lindab. Comfort and Design. Product overview / symbols. Theory. Ceiling diffusers. Ceiling diffusers - visible.

Nozzles. About Lindab. Comfort and Design. Product overview / symbols. Theory. Ceiling diffusers. Ceiling diffusers - visible. Nozzles About Lindab Comfort and Design Product overview / symbols Theory Ceiling diffusers Ceiling diffusers - visible Plenum boxes Wall diffusers Nozzles Ventiduct Grilles Displacement diffusers VAV

More information

Circular duct grille. Dimensions. Description. Maintenance The grille should be removed to gain access to the duct.

Circular duct grille. Dimensions. Description. Maintenance The grille should be removed to gain access to the duct. Dimensions B+0 A+0 A B Description RGS is a rectangular ventilation grille with vertical adjustable bars for direct installation in circular ducts. The grille can be used for both supply and exhaust air.

More information

Air distribution systems. Adjustable radial outlet RA-V...

Air distribution systems. Adjustable radial outlet RA-V... Air distribution systems Adjustable radial outlet RA-V... DS E 0.2013 Construction design Preliminary remarks KRANTZ KOMPONENTEN has developed its wellknown, successful radial outlet into an adjustable

More information

Plain diffuser. Dimensions

Plain diffuser. Dimensions Dimensions ØU Ød 22 37 ØD Description is a circular diffuser with unperforated face plate and can be used for both supply and extract air. is suitable for horizontal supply of cooled air where a high impulse

More information

Nozzle diffuser. Dimensions

Nozzle diffuser. Dimensions Nozzle diffuser GTI Dimensions Installation Ød Description GTI is a flexible supply air nozzle that is suitable for ventilation of large areas. The nozzle can be used for both heated and cooled air and

More information

Circular duct grille

Circular duct grille Dimensions B+0 A+0 A B Description is a rectangular ventilation grille with vertical adjustable bars for direct installation in circular ducts. The grille can be used for both supply and exhaust air. The

More information

Plain diffuser. Dimensions

Plain diffuser. Dimensions Dimensions Ø U Ød B C Ø E Ø A Description is a circular diffuser with an unperforated adjustable face plate and can be used for both supply and extract air. The diffuser can be switched between horizontal

More information

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS Variable or constant flow regulation or constant pressure regulation Wireless communication via radio Integrated sensor

More information

Rectangular air volume controller RWPA

Rectangular air volume controller RWPA Rectangular air volume controller RWPA TECHNICAL DATA - 2012 page 189 Rectangular air volume controller RWPA Rectangular air volume controller RWPA enables automatic airflow control. RWPA is suitable for

More information

Grille. Min. - max. dimensions

Grille. Min. - max. dimensions Min. - max. dimensions H L 0 00 75 00 Standard grilles are available with mm pitch within the above min. and max. sizes. Customized sizes available on request. Description is an adjustable single or double

More information

Constant flow damper

Constant flow damper Constant flow damper DAU Dimensions B Ød l Description Constant flow damper with manual setting of one flow DAU is a constant flow damper, which facilitates balancing of entilation systems and gies correct

More information

Mechanical flow-rate controllers

Mechanical flow-rate controllers L D L D L D Mechanical flow-rate controller MRP-1 (Circular) Description With the circular air flow controllers with automated action, the air flow rate is controlled via an asymmetrical control flap pivoting

More information

KSAb

KSAb --------------------------------------------------------- ---------------------------------------------------------------------- Electronic slave and constant flow regulator for air flow regulation FUNCTION

More information

KZMb

KZMb -------------------------------------------------------- Electronic zone controller for pressure regulation ---------------------------------------------------------------------- FUNCTION KZM is an electronic

More information

Constant-/variable flow damper

Constant-/variable flow damper lindab constant -/ariable flow dampers Constant-/ariable flow damper DAU Dimensions B Ød l Description Constant flow damper with manual setting of one flow DAU is a constant flow damper, which facilitates

More information

Multi-cone diffuser. Dimensions. Description FKD is an adjustable circular multi-cone diffuser, which is typically used for supply air.

Multi-cone diffuser. Dimensions. Description FKD is an adjustable circular multi-cone diffuser, which is typically used for supply air. Dimensions Vertical Ø N D F G Ø A Ø B C Horizontal Description is an adjustable circular multi-cone diffuser, which is typically used for supply air. The diffuser can be switched between horizontal and

More information

Krantz Components. Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems

Krantz Components. Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems DS E 01. with guide ring or jet straightener Preliminary remarks The variable twist outlet with guide ring

More information

Krantz. Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems

Krantz. Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems Krantz Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems DS E 01.18 Variable twist outlet with guide ring or jet straightener Preliminary remarks The variable

More information

Circular air volume controller RWOA

Circular air volume controller RWOA Circular air volume controller RWOA TECHNICAL DATA page 7 Circular air volume controller RWOA Circular air volume controller RWOA enables automatic airflow control. RWOA is suitable for use in systems

More information

KZPb

KZPb ---------------------------------------------------------- ---------------------------------------------------------------------- Electronic constant pressure regulator FUNCTION KZP is an electronic pressure

More information

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS Square extract air diffuser QUICK FACTS Perforated air diffuser front face Manages large extract airflows Flush design Designed for modular suspended ceilings Quick Access front face Can be combined with

More information

Dimensions. Order code. Materials and finish. lindab ceiling diffusers

Dimensions. Order code. Materials and finish. lindab ceiling diffusers LKP Description LCP is a flush-mounted square diffuser with a circular unperforated face plate for installation in ceiling systems. LCP can be used for both supply and exhaust air. LCP is suitable for

More information

Supply air nozzle. Dimensions. DAD-0 With flange for mounting on a wall or duct side.

Supply air nozzle. Dimensions. DAD-0 With flange for mounting on a wall or duct side. A imensions A-0 With flange for mounting on a wall or duct side. Ø ( ) 0 Ø F Ø Nom 0 0 Ø A Ø B Ø E escription A is an adjustable supply air nozzle suitable for ventilation of large areas where long throws

More information

GTH. Rectangular double deflection grille QUICK FACTS

GTH. Rectangular double deflection grille QUICK FACTS Rectangular double deflection grille QUICK FACTS For supply air Adjustable air deflectors Cleanable Installed using mounting frames FHB / FHA or commissioning box TRG Available in alternative colours A

More information

VK2 volume flow controller Overview

VK2 volume flow controller Overview New option with sound attenuator Maintenance-free VK2 volume flow controller that operates without an auxiliary power supply, for ventilation and air conditioning systems. Adjustable on site. Outstanding

More information

SWIFT Ceiling. Square ceiling air diffuser for supply air QUICK FACTS

SWIFT Ceiling. Square ceiling air diffuser for supply air QUICK FACTS Square ceiling air diffuser for supply air QUICK FACTS Flush design Also available in a version for extract air. Designed for modular suspended ceilings (600 x 600 mm) Quick Access Adapter for systemized

More information

GRC. Circular egg crate grille for transfer/extract air and wall/ceiling mounting QUICK FACTS

GRC. Circular egg crate grille for transfer/extract air and wall/ceiling mounting QUICK FACTS Circular egg crate grille for transfer/extract air and wall/ceiling mounting QUICK FACTS For exhaust air 91% free area Handles large airflows Cleanable Can be used with commissioning box ALS Standard colour

More information

Air distribution systems. Radial outlet RA-N2...

Air distribution systems. Radial outlet RA-N2... Air distribution systems Radial outlet RA-N... DS E 0.01 Radial outlet RA-N Preliminary remark KRANTZ KOMPONENTEN radial outlets RA-N have fixed radial vanes and are available with circular or square face.

More information

Ceiling Diffuser. Type ADLR with circular face. Type ADLR-Q with square face 2/16/EN/8

Ceiling Diffuser. Type ADLR with circular face. Type ADLR-Q with square face 2/16/EN/8 2/16/EN/8 Ceiling Diffuser Type ADLR with circular face Type ADLR-Q with square face TROX GmbH Telephone +49/28 45/2 02-0 Telefax +49/28 45/2 02-2 65 Heinrich-Trox-Platz e-mail trox@trox.de D-47504 Neukirchen-Vluyn

More information

SWIFTTM. Ceiling. Square ceiling air diffuser for supply air

SWIFTTM. Ceiling. Square ceiling air diffuser for supply air SWIFTTM Ceiling SWIFT Ceiling Square ceiling air diffuser for supply air Quick facts Flush design Also available in a version for extract air. Designed for modular suspended ceilings (600 x 600 mm) Quick

More information

CDD/CDR. Circular ceiling diffuser for supply air QUICK FACTS

CDD/CDR. Circular ceiling diffuser for supply air QUICK FACTS Circular ceiling diffuser for supply air QUICK FACTS Spread pattern can be shielded Used with commissioning box ALS Cleanable Adjustable slot Perforated diffuser face = CDD Non-perforated diffuser face

More information

series 50-PR Square perforated face diffusers

series 50-PR Square perforated face diffusers series 50-PR Square perforated face diffusers www.koolair.com Series 50-PR 1 Square perforated face diffusers CONTENTS Square perforated face diffusers 54-FR Description 2 Coding and dimensions 3 Quick

More information

STAIRCASE SWIRL DIFFUSERS

STAIRCASE SWIRL DIFFUSERS OVERVIEW Overview: The KPS series staircase swirl diffusers belong to the underchair diffuser category; ideal for places where the best comfort levels are desired both in temperature and acoustics. Cinemas,

More information

NEO-V. Smoke Control Damper SMOKE CONTROL FUNCTION APPLICATION DESCRIPTION. in libraries of

NEO-V. Smoke Control Damper SMOKE CONTROL FUNCTION APPLICATION DESCRIPTION. in libraries of OKE CONTRO in libraries of EI (v ew -h ow -i o) 0 C 000 AA multi EN -:0 EN -:0 Certificate of Constancy of Performance -CPR-0/00 Damper tightness class: Casing tightness class: C EN-:0 FUNCTION The smoke

More information

Krantz Components. Twist outlet DD-N... for ceiling installation. Air distribution systems

Krantz Components. Twist outlet DD-N... for ceiling installation. Air distribution systems Krantz Components Twist outlet DD-N... for ceiling installation Air distribution systems DS E 0. Twist outlet Preliminary remarks and construction design Preliminary remarks Twist outlets for ceiling installation

More information

CDD/CDR. Single cone ceiling diffusers for supply air. Quick facts. Quick guide CDD/CDR A I R F L O W - S O U N D L E V E L

CDD/CDR. Single cone ceiling diffusers for supply air. Quick facts. Quick guide CDD/CDR A I R F L O W - S O U N D L E V E L Single cone ceiling diffusers for supply air Quick facts Spread pattern can be shielded Used with commissioning box ALS Cleanable Adjustable slot Perforated diffuser face = CDD Imperforated diffuser face

More information

Krantz. RL-C2 radial slot outlet. Air distribution systems

Krantz. RL-C2 radial slot outlet. Air distribution systems RL-C2 radial slot outlet Air distribution systems DS E 04.1 Introduction The RL-C2 radial slot outlet with circular face generates a turbulent mixed flow. It is used for supply and return air distribution

More information

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS Square ceiling air diffuser for supply air and extract air QUICK FACTS Flexible distribution pattern, yet the acoustic data remains the same One K-factor regardless of distribution pattern Designed for

More information

Krantz. Radial slot outlet with square blade array RL-Q2... circular blade array RL-R2... Air distribution systems DS 4186 E 09.

Krantz. Radial slot outlet with square blade array RL-Q2... circular blade array RL-R2... Air distribution systems DS 4186 E 09. Krantz Radial slot outlet with square blade array RL-Q2... circular blade array RL-R2... Air distribution systems DS 86 E 09./1 with square and circular blade array Preliminary remark The radial slot outlet

More information

2/S12 DIFFUSER FOR HORIZONTAL OR VERTICAL DISCHARGE DHV. v 3.3 (en)

2/S12 DIFFUSER FOR HORIZONTAL OR VERTICAL DISCHARGE DHV. v 3.3 (en) 2/S12 v (en) DIFFUSER FOR HORIZONTAL OR VERTICAL DISCHARGE DHV 6 7 wwwklimaopremahr wwwklimaopremahr TABLE OF CONTENTS Horizontalvertical diffuser 9 Ordering key 1 Selection diagrams 1 DHV Ceiling diffuser

More information

Air distribution systems. Linear whirl outlet WL...

Air distribution systems. Linear whirl outlet WL... Air distribution systems Linear whirl outlet WL... DS 0 E 1.013 Preliminary remarks Mode of operation The linear whirl outlet generates turbulent mixing ventilation. It can be installed on or in a wall

More information

ALC. ALBATROSS Supply air terminal for large airflows

ALC. ALBATROSS Supply air terminal for large airflows ALBATROSS Supply air terminal for large airflows Quick facts Large airflows Suitable for cooling or heating Manual or motorised adjustment Pressure drop independent of selected spread pattern Can be used

More information

Linear diffuser. Description

Linear diffuser. Description A C B + D Description is a rectangular linear diffuser in aluminium. is suitable for both supply and exhaust air. is equipped with air guide baffles, making it possible to use for horizontal supply air.

More information

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air Ceiling Square ceiling air diffuser for supply air and extract air Quick facts Flexible distribution pattern, yet the acoustic data remains the same One K-factor regardless of distribution pattern Designed

More information

Valve Supply and exhaust air

Valve Supply and exhaust air IRY Dimensions Description The valve is designed for installation at a wall or in a ceiling. It can be used for new-build and for replacement. Its smart grip function ensures an easy installation. Its

More information

Air distribution systems. Adjustable induction outlet IN-V...

Air distribution systems. Adjustable induction outlet IN-V... ir distribution systems djustable induction outlet IN-V... DS E 0. Construction and function Preliminary remarks In addition to its induction outlet with preset discharge direction ), KRNTZ KOMPONENTEN

More information

CIRCO. Sound-attenuating transfer unit QUICK FACTS

CIRCO. Sound-attenuating transfer unit QUICK FACTS Sound-attenuating transfer unit QUICK FACTS Supplied in pairs For the transfer of air through a wall Fits in a circular cut opening Simple to install Mounting frame integrated into the transfer diffuser

More information

Swirl Diffuser. Type SDW T 2.2/1/B/1. recommended for room heights from approx m

Swirl Diffuser. Type SDW T 2.2/1/B/1. recommended for room heights from approx m T 2.2/1/B/1 Swirl Diffuser Type SDW recommended for room heights from approx. 2.60... 4.00 m TROX UK Ltd Caxton Way Thetford Norfolk IP24 3SQ Telephone +44(0) 1842 54545 Telefax +44(0) 1842 63051 e-mail

More information

Slot diffuser. Type VSD35 2/2.6/B/3. with 35 mm wide slot

Slot diffuser. Type VSD35 2/2.6/B/3. with 35 mm wide slot 2/2.6/B/3 Slot diffuser Type VSD35 with 35 mm wide slot TROX UK Ltd Telephone +44 (0) 1842 754545 Caxton Way Telefax +44 (0) 1842 763051 Thetford e-mail trox@troxuk.co.uk Norfolk IP24 3SQ www.troxuk.co.uk

More information

EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS. FCP 2008 testing procedures FCP acoustical test method pag. 1

EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS. FCP 2008 testing procedures FCP acoustical test method pag. 1 EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS FCP 2008 testing procedures FCP acoustical test method pag. 1 CONTENTS 1 - PURPOSE... 3 2 - NORMATIVE REFERENCES... 3 3 - DEFINITIONS... 3 3.1

More information

Attenuation. Witt&Sohn AG Oct-14

Attenuation. Witt&Sohn AG Oct-14 Noise Generation & Attenuation CONTENT Noise Generation & Attenuation 1. General 2. Jet fans 3. Axial Fans 2 General Sound Power L W depends on Vibrations Number of blades Turbulences Rotational speed

More information

Worth noting. Introduction. Key figures. lindab architect. Picture 1. Architect Circum, Luna and Prisma.

Worth noting. Introduction. Key figures. lindab architect. Picture 1. Architect Circum, Luna and Prisma. Contact, Overview, Index Guideline heating and cooling Plexus Professor / Professor Plus Premum / Premax / Solus Architect Polaris I & S Plafond Podium Celo Cabinett Capella Carat Fasadium Atrium / Loggia

More information

Air distribution systems. Jet nozzle DW-N2... Swivel jet nozzle DW-V2... Twist nozzle DW-V2-...-DR

Air distribution systems. Jet nozzle DW-N2... Swivel jet nozzle DW-V2... Twist nozzle DW-V2-...-DR Air distribution systems Jet nozzle DW-N... Swivel jet nozzle DW-V... Twist nozzle DW-V-...-DR DS E 01. Jet nozzle and twist nozzle Preliminary remarks Jet nozzle DW N Swivel jet nozzle DW V Twist nozzle

More information

AX6 adjustable blades swirl diffusers

AX6 adjustable blades swirl diffusers AX6 adjustable blades swirl diffusers AX6 series swirl diffusers are designed to be applied in air conditioning, ventilation and heating in different premises from 2,6 meters high and temperature differential

More information

Pa 200 100 50 100-80 125-100 160-125 200-160 250-200 315-250 400-315 500-400 630-500 p t drop Pressure 10 5 800-630 1000-800 1250-1000 1 0,5 20 50 100 500 1000 5000 l/s 100 500 1000 5000 10000 m 3 /h Volume

More information

PREDICTION OF FAN SOUND POWER

PREDICTION OF FAN SOUND POWER PREDICTION OF FAN SOUND POWER Fan noise is a function of the fan design (K w ), volume flow rate (Q), total pressure (P t ) and efficiency (c). The sound power generation of a given fan performing a given

More information

KSV. Slot diffusers. Ordering code. Description. Linear diffusers 1 / 16

KSV. Slot diffusers. Ordering code. Description. Linear diffusers 1 / 16 Linear diffusers 1 / 1 KSV Slot diffusers Ordering code Number of slots Diffuser Length (mm) KSV - 1... - 19 Description KSV is an air terminal element primarily designated for air supply. It is suitable

More information

Linear ceiling diffuser

Linear ceiling diffuser L-0--01e Linear ceiling diffuser Type LDD / LDDL Contents Realisation Application Safety instructions Contents Realisation Application Safety instructions Dimensions 3 Dimensions Installation Quick selection

More information

HELLA. Linear slot diffuser. Ordering codes. HELLA - Linear diffuser. Linear Diffusers 1 / 18. Example of the ordering code HELLA B-0-0-AN

HELLA. Linear slot diffuser. Ordering codes. HELLA - Linear diffuser. Linear Diffusers 1 / 18. Example of the ordering code HELLA B-0-0-AN Linear Diffusers / 8 HELLA Linear slot diffuser Ordering codes HELLA - Linear diffuser HELLA - Number of slots... Diffuser length L (mm) ) Increment mm... Deflector colour Damper Diffuser construction

More information

The diagram below. to the by the. outlet into. calculation. Since TRANSMISSION VIA STRUCTURE. Vibration Via Supports Duct Breakout

The diagram below. to the by the. outlet into. calculation. Since TRANSMISSION VIA STRUCTURE. Vibration Via Supports Duct Breakout NOISE CONTROL IN VENTILATING SYSTEMS INTRODUCTION The diagram below shows the various noise sources and transmission paths of plant rooms and ventilation systems. For the ventilation system this can be

More information

Slot diffusers. Slot diffusers, Round duct diffusers. Slot diffusers. Slot diffusers LD-13, LD-14

Slot diffusers. Slot diffusers, Round duct diffusers. Slot diffusers. Slot diffusers LD-13, LD-14 , Round duct diffusers D-, D- Application D- and D- slot diffusers are designed for the supply of air in rooms with floor to ceiling heights of.5 to m for supplying either cold or warm air, in particular

More information

DCG adjustable core circular diffusers

DCG adjustable core circular diffusers Lievore, Altherr & Molina DCG adjustable core circular diffusers The DCG series diffusers are designed to be used in air-conditioning, ventilation and heating in premises from,6 meters high. They can be

More information

Swirl diffusers, Variable swirl diffusers Swirl diffusers

Swirl diffusers, Variable swirl diffusers Swirl diffusers IMP Klima, Variable swirl diffusers Swirl diffuser OD- Fixed grille For air supply or exhaust Recommended temperature difference between supplied and internal air in the room is between 0 to 0 K Low static

More information

APEX DYNAMICS, INC. Staianless

APEX DYNAMICS, INC. Staianless APEX DYNAMICS, INC. HIGH PRECISION PLANETARY GEARBOXES AE / AER Series Staianless High precision high speed planetary gearboxes AE / AER series Apex Dynamics, Inc. is the world s most productive manufacturer

More information

SV-2, SV-1, AVS, AVSL, SI Grilles

SV-2, SV-1, AVS, AVSL, SI Grilles Grilles SV-2, SV-1, AVS, AVS-L TECHNICAL DATA - 2004 page 351 SV-2, SV-1, AVS, AVSL, SI Grilles SV-2 SV-1 47 (H-17) x (W-17) (H-12) x (W-12) AVS, SI AVSL S SV, AVS, AVSL and SI grilles are designed for

More information

SINGLE. Technical Data Book. Big Ceiling for Europe (R410A, 50Hz, H/P) Model : AC***JNCDEH (ODU: AC***JXAD*H)

SINGLE. Technical Data Book. Big Ceiling for Europe (R410A, 50Hz, H/P) Model : AC***JNCDEH (ODU: AC***JXAD*H) SINGLE Technical Data Book Big for Europe (R4A, Hz, H/P) Model : AC***JNCDEH (ODU: AC***JXAD*H) History Version Modification Date Remark Ver.1. Release SINGLE Big for Europe.4.3 Ver.1.1 Modification for

More information

Swirl Diffusers Type DLA 7 and DLA 8

Swirl Diffusers Type DLA 7 and DLA 8 LTG Incorporated Swirl Diffusers Type DLA 7 and DLA 8 LTG Incorporated 1 Corporate Drive, Suite D Spartanburg, SC 93 PO Box 889, Spartanburg, SC 9 USA Tel: 86-599-63 Fax: 86-599-63 e-mail: info@ltg-inc.net

More information

Use. Worth noting. Key figures. Installation. lindab fasadium

Use. Worth noting. Key figures. Installation. lindab fasadium Contact, Overview, Index Guideline heating and cooling Plexus Professor / Professor Plus Premum / Premax / Solus Architect Polaris I & S Plafond Podium Celo Cabinett Capella Carat Atrium / Loggia Regula

More information

BNA Series. PLENUM FAN with Backward Wheels

BNA Series. PLENUM FAN with Backward Wheels BNA Series PLENUM FAN with Backward Wheels BNA Series BNA Series Plenum Fans Backward wheels Kruger Plenum Fans are designed for air handling applications where the fan operates unhoused within a plenum.

More information

Supply air beam. Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor / Professor Plus. Premum / Premax / Solus.

Supply air beam. Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor / Professor Plus. Premum / Premax / Solus. Contact, Overview, Index Guideline heating and cooling Plexus Professor / Professor Plus Premum / / Solus Architect Polaris I & S Plafond Podium Celo Cabinett Capella Carat Fasadium Atrium / Loggia Regula

More information

Twin City Fan Companies. Fan System Effects

Twin City Fan Companies. Fan System Effects Fan System Effects Outline Fan Testing Review Definition of System Effect Old ASHRAE guidelines AMCA 201 System Effect Factors Examples Demonstration Aimed at the fan system designer There are two goals:

More information

Variable swirl diffusers

Variable swirl diffusers Swirl diffusers, Variable swirl diffuser OD- Application Diffuser is designed for air conditioning of rooms with floor to ceiling highs of to 0 m and high induction requirements. It is suitable for large

More information

Swirl diffusers, Variable swirl diffusers

Swirl diffusers, Variable swirl diffusers 0 Variable swirl diffusers SLOT IFFUSERS, ROUN UCT IFFUSERS SWIRL IFFUSERS, VARIABLE SWIRL IFFUSERS CIRCULAR IFFUSERS, SQUARE IFFUSERS VENTILATING GRILLES, VENTILATING VALVES, Variable swirl diffusers

More information

6-way valve with room temperature controller. Balanced climate control. World premiere! e. Cost and energy economies

6-way valve with room temperature controller. Balanced climate control. World premiere! e. Cost and energy economies 6-way valve with room temperature controller. Balanced climate control. We set standards. www.belimo.eu World premiere! e Virtuoso performance to raise comfort and cut costs. Sustainable well-being hinges

More information

EXPERIMENTAL INVESTIGATION OF NOISE PARAMETERS IN HVAC SYSTEMS

EXPERIMENTAL INVESTIGATION OF NOISE PARAMETERS IN HVAC SYSTEMS The 40 th International Conference on Mechanics of Solids, Acoustics and Vibrations & The 6th International Conference on Advanced Composite Materials Engineering ICMSAV2016& COMAT2016 Brasov, ROMANIA,

More information

ISO INTERNATIONAL STANDARD. Acoustics Acoustic insulation for pipes, valves and flanges

ISO INTERNATIONAL STANDARD. Acoustics Acoustic insulation for pipes, valves and flanges INTERNATIONAL STANDARD ISO 15665 First edition 2003-08-15 Acoustics Acoustic insulation for pipes, valves and flanges Acoustique Isolation acoustique des tuyaux, clapets et brides Reference number ISO

More information

series FLOOR

series FLOOR series FLOOR www.koolair.com Floor Series 3 DSA, DSA-PR, DSA-HV and DF-CP-MT Floor swirl diffusers CONTENTS DSA / DSA-PR / DSA-HV diffusers 4 Models and dimensions 5 DSA Selection tables 6 DSA Selection

More information

Sound power level measurement in diffuse field for not movable sources or emitting prominent discrete tones

Sound power level measurement in diffuse field for not movable sources or emitting prominent discrete tones CFA 2018 - Le Havre Sound power level measurement in diffuse field for not movable sources or emitting prominent discrete tones F. Bessaca et P. Cellardb a CETIAT, Domaine Scientifique de la Doua, 25,

More information

FAN TERMINOLOGY. t = 1.2 kg/m 3 (Standard air density at 20 C and 1013mb. V = duct air velocity, m/s.

FAN TERMINOLOGY. t = 1.2 kg/m 3 (Standard air density at 20 C and 1013mb. V = duct air velocity, m/s. +7 (0)1 55 1077 +7 (0)1 55 797 FAN TERMINOLOGY These notes are designed to explain some of the terms that are used in describing the characteristics of fans and the relationship between the fan performance

More information

Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor. Pilot. Architect. Polaris I & S. Plafond. Podium. Celo. Cabinett.

Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor. Pilot. Architect. Polaris I & S. Plafond. Podium. Celo. Cabinett. & S Contact, Overview, Index Guideline heating and cooling Plexus Professor Pilot Architect & S Plafond Podium Celo Cabinett Capella Carat Fasadium Atrium H & C /Loggia Regula Drypac Lighting TEKNOsim

More information

Technical Explanation for Axial Fans

Technical Explanation for Axial Fans CSM_Axial_TG_E Introduction What Is an Axial? Axial fans are used for stable cooling in many different applications and locations. If the temperature of a device increases, the lives of its internal parts

More information

Ecolibrium. All natural. A new style for supermarkets? THE OFFICIAL JOURNAL OF AIRAH AUGUST 2017 VOLUME 16.7 RRP $14.95

Ecolibrium. All natural. A new style for supermarkets? THE OFFICIAL JOURNAL OF AIRAH AUGUST 2017 VOLUME 16.7 RRP $14.95 THE OFFICIAL JOURNAL OF AIRAH Ecolibrium AUGUST 2017 VOLUME 16.7 RRP $14.95 PRINT POST APPROVAL NUMBER PP352532/00001 All natural A new style for supermarkets? ESTABLISHED 1947 Celebrating 70 years as

More information

On predicting wind turbine noise and amplitude modulation using Amiet s theory

On predicting wind turbine noise and amplitude modulation using Amiet s theory On predicting wind turbine noise and amplitude modulation using Amiet s theory Samuel Sinayoko 1 Jeremy Hurault 2 1 University of Southampton, ISVR, UK 2 Vestas, Isle of Wight, UK Wind Turbine Noise 2015,

More information

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50 /way ball valve with electric rotary actuator, ball valve in plastic, N 50 Suitable for aggressive media High flow rate value Actuator with adjustable limit switches Visual position indicator Type 0 can

More information

AN INVESTIGATION OF THE EFFECT OF UNEVEN BLADE SPACING ON THE TONAL NOISE GENERATED BY A MIXED FLOW FAN SUMMARY INTRODUCTION

AN INVESTIGATION OF THE EFFECT OF UNEVEN BLADE SPACING ON THE TONAL NOISE GENERATED BY A MIXED FLOW FAN SUMMARY INTRODUCTION AN INVESTIGATION OF THE EFFECT OF UNEVEN BLADE SPACING ON THE TONAL NOISE GENERATED BY A MIXED FLOW FAN Ludovic DESVARD, Jeremy HURAULT, Muhammad Affendi Bin MOHAMED ZAMZAM, Ash SYMES DYSON Ltd, Aeroacoustic

More information

VRF Technical Data Book

VRF Technical Data Book VRF Technical Data Book DVM S for Euro_ET (R4A, Hz, HP) Model : Premium (Compact / Energy Efficiency) Type Standard Type History Version Modification Date Remark Ver. 1. Release DVM S (R4A, Hz, HP) for

More information

THE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP

THE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP I N V E RT E R ion Range exible Combine Modular TDV I TDV I TDV I INVERTER INVERTER INVERTER 14, 16, 18, 20, 22 HP TDV I 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP INVERTER INVERTER INVERTER TDV I INVERTER

More information

NOP, NOT and NOX. Adaptable, flexible supply air diffusers with ultra low height for free installation. climecon.fi 07.16

NOP, NOT and NOX. Adaptable, flexible supply air diffusers with ultra low height for free installation. climecon.fi 07.16 NOP, NOT and NOX Adaptable, flexible supply air diffusers with ultra low height for free installation 07.16 NOP, NOT and NOX The most outstanding features of the NOP, NOT and NOX supply air diffusers are

More information

LECTURE-11 FAN AND DUCT SYSTEM-2

LECTURE-11 FAN AND DUCT SYSTEM-2 L ecturer: -D D r. E sam M ejbil A bid Subject: A ir Conditioning and R efrigeration Year: Y Fourth B.Sc. D E P A R TM E N O F M E CH A N ICA L E N G IN E E R IN B abylon U niversity College of E ngineering

More information

Analysis of Split Air Conditioner Noise using Sound Intensity Mapping

Analysis of Split Air Conditioner Noise using Sound Intensity Mapping Analysis of Split Air Conditioner Noise using Sound Intensity Mapping M. S. Mohd Sani *,1,2,a, I. Zaman 2,b and M. Rahman 2,c 1 Advance Structural Integrity and Vibration Research (ASIVR), Faculty of Mechanical

More information

Sound Rating of Ducted Air Moving and Conditioning Equipment

Sound Rating of Ducted Air Moving and Conditioning Equipment AHRI Standard 260 (I-P) 2017 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment IMPORTANT SAFETY DISCLAIMER AHRI does not set safety standards and does not certify or guarantee the

More information

W-8 Inlet In-duct Array Evaluation

W-8 Inlet In-duct Array Evaluation https://ntrs.nasa.gov/search.jsp?r=2184548 218-9-16T15:19:18+:Z National Aeronautics and Space Administration W-8 Inlet In-duct Array Evaluation Rick Bozak NASA Glenn Research Center Acoustics Technical

More information

Supply air beam. Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor / Professor Plus. Premum / Premax / Solus.

Supply air beam. Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor / Professor Plus. Premum / Premax / Solus. Contact, Overview, Index Guideline heating and cooling Plexus Professor / Professor Plus Premum / Premax / Architect Polaris I & S Plafond Podium Celo Cabinett Capella Carat Fasadium Atrium / Loggia Regula

More information

Calio-Therm NC Type Series Booklet

Calio-Therm NC Type Series Booklet High-efficiency Drinking Water Pump Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,

More information

Document No. EO Original Nov, 2008 (Revised )

Document No. EO Original Nov, 2008 (Revised ) TOSHIBA Barcode Printer B-EV4 SERIES Parts List Document No. EO8-33025 Original Nov, 2008 (Revised ) PRINTED IN JAPAN EO8-33025 (Revision: Feb. 18, 2011) TABLE OF CONTENTS HOW TO USE THIS PARTS LIST MECHANICAL

More information

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011 SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with

More information