50 Hz. e-lne Series SINGLE IN-LINE ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS. ErP 2009/125/EC

Size: px
Start display at page:

Download "50 Hz. e-lne Series SINGLE IN-LINE ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS. ErP 2009/125/EC"

Transcription

1 Hz e-lne Series SINGLE IN-LINE ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS ErP 9/1/EC Cod Rev. F Ed.3/16

2 Xylect TM Xylect TM is a pump solution software with an extensive online database of product information across the entire range of pumps and related products, with multiple search options and helpful project management facilities. The system holds up-to-date product information on thousands of products and accessories. Xylect TM can be available: On the website On DVD Loop U On Mobile Apps For more information, please, see page Ecodesign Directive (ErP) Over last decade the European Commission with the Energy Efficiency Plan pushed the European Parliament and the Council to adopt specific measures to the purpose of reducing energy consumption and further negative environmental impacts. Through the Directives /3/EC, energy-using products (EuP), and 9/1/EC, energy-related products (ErP) a framework for ecodesign requirements was established. The Commission Regulations (EC) No 6/9 and (EU) No /1 have implemented two directives with regard to ecodesign requirements for three-phase Hz electric motors placed on the market and put into service inside EU zone as self-alone units or integrated in other products. This regulation states that motors must have efficiency level IE3 (or IE + Variable Speed Drive) from 1 st January 1 for 7, to 37 kw rated powers and from 1 st January 17 for,7 to 37 kw ones. The Commission Regulation (EU) No 7/1 has implemented two directives with regard to ecodesign requirements for some types of clean water pumps placed on the market and put into service inside EU zone as self-alone units or integrated in other products. This regulation states that water pumps shall have index MEI. as minimum from 1 st January 1. That index comes from a dedicated formula which considers hydraulic efficiency values at best efficiency point (BEP), 7 % of the flow at BEP (Part load PL) and 11 % of the flow at BEP (Over load OL). The Lowara e-lne series, for the models in the scope of the regulations above, is ErP compliant, having an index MEI equal or higher than, and IE3 motor efficiency. Lowara, HYDROVAR, Xylect are trademarks or registered trademarks of Xylem Inc. or one of its subsidiaries. All other trademarks or registered trademarks are property of their respective owners

3 CONTENTS General Introduction... Applications...6 Identification code...8 Rating plate...9 List of Models at Hz, poles...1 List of Models at Hz, poles...11 Pump cross-section and main components...1 Mechanical seals...1 Motors (ErP 9/1/EC)...1 Pumps (ErP 9/1/EC)...3 Minimum efficiency index (MEI)... Hydraulic performance range at Hz, poles... Table of hydraulic performances at Hz, poles...6 Hydraulic performance range at Hz, poles...8 Table of hydraulic performances at Hz, poles...9 Operating characteristics at Hz, poles...33 Operating characteristics at Hz, poles...1 Dimensions and weights...83 LNE..H (e-lne with Hydrovar)...99 Accessories Report and declarations...13 Technical appendix...1 3

4 e-lne SERIES HYDRAULIC PERFORMANCE RANGE AT Hz, POLES Q [Imp gpm] Q [US gpm] H [m] 3 LNE,, 6, 8, 1 (9 rpm) 1 8 H [ft] Q [m 3 /h] Q [l/s] A38_B_CH HYDRAULIC PERFORMANCE RANGE AT Hz, POLES Q [Imp gpm] Q [US gpm] 3 H [m] LNE,, 6, 8, 1, 1, 1,, (1 rpm) H [ft] Q [m 3 /h] Q [l/s] A39_B_CH

5 e-lne SERIES GENERAL INTRODUCTION The new Lowara e-lne Series is the result of the close collaboration between our customers and us; the new range has been redesigned and improved to meet the Commercial Building Services (CBS) requirements, in terms of performances and energy saving. In addition the new Lowara e-lne Series can be customized to meet the needs of the Industry, keeping the bestin-class quality in production that affords our pumps continuous reliability and robustness in operation. Pump design The new Lowara e-lne Series is a single-impeller centrifugal pump with in-line suction and delivery flanges. The e-lne Series has a Back pull-out design (impeller, adapter, and motor can be extracted without disconnecting the pump body from the piping system). The pumps have cast iron casing as standard; the impeller standard material is cast iron but is also available in bronze and stainless steel. The pumps are equipped with interchangeable mechanical seals and IE3 efficiency motors; and are available in the following constructions: Extended shaft Close-coupled by means of an adaptor bracket with an impeller keyed directly to the special motor shaft extension. Stub shaft Rigid-coupled with a bracket, an adaptor and a rigid coupling keyed to the standard motor shaft extension. Hydraulic specifications Maximum delivery: 3 m 3 /h ( poles range). 9 m 3 /h ( poles range). Maximum head: 9 m ( poles range). 7 m ( poles range). Hydraulic performance compliant with ISO 996:1 Grade 3B. Grade B and 1B available upon request. Fluid temperature range: - standard version (with mechanical seal BQ1EGG-WA and EPDM gasket) - to +1 C - versions on request (depending on mechanical seal and gasket) -* or - to +1 or +1 C. Maximum operating pressure: - standard version (with mechanical seal BQ1EGG-WA) 16 9 C and 1 1 C - versions on request (with other mechanical seals) 16 1 C and 1,9 1 C * Fluoro-elastomer: FPM (old ISO), FKM (ASTM & new ISO). Motor specifications Squirrel cage in short circuit enclosed construction with external ventilation (TEFC). -pole and -pole ranges. IP protection degree as motor (EN 63-), IPX as electro-pump (EN 69). Performances according to EN IE3 efficiency level (three-phase,7 to 37 kw). 1 (F) insulation class. Standard voltage: 1 x - V Hz for power up to, kw 3 x -/38-1 V Hz for power up to 3 kw. 3 x 38-1/66-69 V Hz for power above 3 kw. Maximum ambient temperature: C. Note Anti-clockwise rotation when facing pump s suction port. Pump does not include counter-flanges. List of the Directives - Machinery Directive MD 6//EC and the main technical norms EN 89, EN 6-1 (safety) EN 19- (cast iron flanges) - Electromagnetic Compatibility Directive EMCD /18/EC - Ecodesign requirements for energy-related products ErP 9/1/EC Regulation (EC) No 6/9, Regulation (EU) No /1, Regulation (EU) No 7/1 EN , EN EN 63-3:9, IEC :1 (electric motors)

6 e-lne SERIES COMMERCIAL BUILDING SERVICES (CBS) APPLICATIONS & BENEFITS Applications The Lowara e-lne Series is suitable for many different applications demanding variable duty points, reliable, and efficient products in cost saving operation. The Lowara e-lne Series can be used for the following CBS applications: HVAC - Liquid transfer in heating systems. - Liquid transfer in air-conditioning systems. - Liquid transfer in ventilation systems. Water Supply - Pressure boosting in commercial buildings. - Irrigation systems. - Water transfer for green houses. Benefits The Lowara e-lne Series permit to achieve the following benefits. Performances: the e-lne pumps are ErP 1 compliant, equipped with IE3 motors, and with hydraulic target points and coverage that satisfy the needs of CBS applications. The standard full cast iron version with PN16, 1 C maximum fluid temperature, and EPDM elastomer is exactly what the CBS Market needs. Reliability: robust construction and high-quality standards in production, interchangeable mechanical seals and wear rings, guarantee a continuous operation without faults and a shorter down time for maintenance. Versatility: beside the standard offer, the Lowara e-lne series is available in different construction as well as with different material configurations for impellers and elastomers. That helps in addressing a wide range of applications. Total cost ownership: the best-in-class hydraulic and electric efficiency, the Hydrovar-equipped versions, the easy and quick maintenance, allow to reduce the operation and maintenance cost and to save energy when the pump is working or is at rest. Pre-post sales support: we are continuously working close to our customers to help them in selecting the right pump for the specific application. A user-friendly selection software is available on the website, on DVD, or on Apps for mobile phones. Experienced engineers are fully dedicated to big projects. 6

7 7

8 e-lne SERIES IDENTIFICATION CODE L N E S / 1 8 A / W V C C Motor power [ to 3 digits] kw x 1 Pump Type [3 digits] [LNE] = in-line single Coupling [1 digit] [E]= extended shaft [S] = stub shaft Motor operation [1 digit] [ ] = standard asynchronous motor [H] = equipped with Hydrovar [X] = other drives Size of the pump [6 to 7 digits] Discharge diameter - nominal impeller diameter e.g. -16, 1-31 Special trimmed Impeller [1 digit] [A or B] = Trimmed medium diameter that doesn t maximize motor power [X] = Trimmed medium diameter to meet customer required duty point Motor type [ digits] [/P] = PLM [/S] = SM [/W] = Weg [/X] = Other N poles [1 digit] [] = poles [] = poles Mech Seal + Oring Config [1 digit] [] = SiC/Carbon/EPDM [] = SiC/Carbon/FKM* [Z] = SiC/SiC/EPDM [W] = SiC/SiC/FKM* [L..] = Tungsten Carbide/ Metal-impreg. carbon/epdm [U..] = Tungsten Carbide/ Metal-impreg. carbon/fkm* Impeller Material [1 digit] [C] = Cast Iron [S] = Fabricated Stainless Steel [B] = Bronze [N] = Cast Stainless Steel (1.8) [R] = Duplex (1.17) EXAMPLES Electrical Voltage + Frequency [digits] Hz H = 1x- V R = 3x-/38-1 V V = 3x38-1/66-69 V P = 3x-8/36-36 V S = 3x-6/-6 V T = 3x9-3/- V W = 3x-6/- V 6 Hz 6F = 1x-3 V 6E = 1x-1 V 6P = 3x-3/38- V 6R = 3x-77/-8 V 6V = 3x-8/- V 6U = 3x38-/66-69 V 6N = 3x-8/36-36 V 6T = 3x33-36/7-6 V Casing Material [1 digit] [C] = Cast Iron * FPM (old ISO), FKM (ASTM & new ISO) LNES 1-16//WRCC In-line single, electric pump stub shaft coupling, DN1 nominal discharge port, 16 mm nominal impeller diameter,, kw rated motor power, WEG IE3 model, pole, Hz -/38-1 V, cast iron casing, cast iron impeller, Silicon Carbide/Carbon/EPDM mechanical seal. LNES 1-//WVCB In-line single, electric pump stub shaft coupling, DN1 nominal discharge port, mm nominal impeller diameter,,kw rated motor power, WEG IE3 model, pole, Hz 38-1/66-69 V, cast iron casing, bronze impeller, Silicon Carbide/Carbon/EPDM mechanical seal. 8

9 e-lne SERIES RATING PLATE ELECTRIC PUMP REGULATION (EU) No 7/ LEGEND 1 - Electric pump unit type - Electric pump unit code 3 - Flow range - Head range - Nominal or maximum pump power 6 - Speed 7 - Serial number, or order number + order position number 9 - Full impeller diameter (only filled in for trimmed impellers) 1 - Trimmed impeller diameter (only filled in for trimmed impellers) 11 - Minimum operating liquid temperature 1 - Maximum operating liquid temperature 13 - Maximum operating pressure 1 - Hydraulic efficiency in best efficiency point ( Hz) 1 - Minimum efficiency index MEI, as per Regulation (EU) No 7/1 ( Hz) 19 - Weight 9

10 e-lne SERIES LIST OF MODELS AT Hz, POLES (*) Models available also in single-phase version. = Available LNE_models-p-en_b_sc LEGEND LNEE : Extended shaft (single version). LNES : Stub shaft (single version). 1

11 e-lne SERIES LIST OF MODELS AT Hz, POLES = Available LNE_models-p-en_b_sc 11

12 LNEE SERIES ELECTRIC PUMP CROSS-SECTION AND MAIN COMPONENTS REF. PART MATERIAL REFERENCE STANDARDS N. EUROPE USA 1 Volute casing Cast iron EN GJL- (JL1) ASTM Class 3 Casing cover Cast iron EN GJL- (JL1) ASTM Class 3 Impeller (,, 6) Stainless steel EN XCrNiMo17-1- (1. AISI 316L Impeller (8, 1) Cast iron EN GJL- (JL13) ASTM Class 3 3 Impeller (8, 1) Bronze EN CuSn1-C (CC8K) UNS C97 Stub shaft Stainless steel EN XCrNiMo17-1- (1.) AISI 316L Wear ring Stainless steel EN XCrNi18-1 (1.31) AISI 3 6 Impeller lock nut and washer Stainless steel EN XCrNiMo17-1- (1.1) AISI Impeller key Stainless steel EN XCrNiMo17-1- (1.) AISI 316L 9 Fill and drain plugs Nickel-plated brass EN 116-CuZn39Pb3 (CW61N) - 11 O-Ring EPDM (standard version) 1 Mechanical seal Carbon / Silicon carbide / EPDM (standard version) 13 Motor adapter * Aluminium EN 176-AC-AlSi11Cu (Fe) (AC61) - Motor adapter Cast iron EN GJL- (JL1) ASTM Class 3 1 Volute casing fastening bolts and screws Carbon steel 1 Pump base (optional) Carbon steel EN * / pole: //6-1, /-16 LNEE-en_a_tm 1

13 LNES SERIES ELECTRIC PUMP CROSS-SECTION AND MAIN COMPONENTS MATERIAL LNES LNE_A_DS REF. PART MATERIAL REFERENCE STANDARDS N. EUROPE USA 1 Volute casing Cast iron EN GJL- (JL1) ASTM Class 3 Casing cover Cast iron EN GJL- (JL1) ASTM Class 3 Impeller (,, 6) Stainless steel EN XCrNiMo17-1- (1.) AISI 316L 3 Impeller Cast iron EN GJL- (JL13) ASTM Class 3 Impeller Bronze EN CuSn1-C (CC8K) UNS C97 Stub shaft Stainless steel EN XCrNiMo17-1- (1.) AISI 316L Stub shaft (8-, 1-, 1-, 1, 1) Stainless steel EN X17CrNi16- (1.7) AISI 31 Wear ring Stainless steel EN XCrNi18-1 (1.31) AISI 3 6 Impeller nut Stainless steel A (~ 1.1) 7 Impeller washer Stainless steel A (~ 1.1) 8 Impeller key Stainless steel EN X6CrNiMo17-1- (1.71) AISI 316Ti 9 Plug Stainless steel EN X6CrNiMo17-1- (1.71) AISI 316Ti 1 Gasket Asbestos-free synthetic fiber AFM 3 11 O-Ring EPDM (standard version) 1 Mechanical seal Carbon / Silicon carbide / EPDM (standard version) 13 Motor adapter * Aluminium EN 176-AC-AlSi11Cu (Fe) (AC61) - Motor adapter Cast iron EN GJL- (JL1) ASTM Class 3 1 Volute - casing fastening screws Carbon steel 1 Pump base (optional) Carbon steel EN * / pole: //6-1, /-16 Lne-en_b_tm 13

14 e-lne SERIES MECHANICAL SEALS Mechanical seal with mounting dimensions according to EN 176 and ISO LIST OF MATERIALS 3 1 LNE_M1_A_ot POSITION 1 - POSITION 3 POSITION - B : Resin impregnated carbon E : EPDM G : AISI 316 A : Antimony impregnated carbon V : FKM (FPM) Q 1 : Silicon carbide U 3 : Tungsten carbide TYPE OF SEAL TYPE POSITION 1 3 ROTATING ASSEMBLY FIXED ASSEMBLY ELASTOMERS SPRINGS STANDARD MECHANICAL SEAL OTHER COMPONENTS PRESSURE lne-lnt_ten-mec-en_a_tm TEMPERATURE (bar) ( C ) B Q 1 E G G - WA B Q 1 E G G 16/1 - +9/+1 OTHER TYPES OF MECHANICAL SEAL B Q 1 V G G B Q 1 V G G *) Q 1 Q 1 E G G Q 1 Q 1 E G G Q 1 Q 1 V G G Q 1 Q 1 V G G *) U 3 A E G G U 3 A E G G U 3 A V G G U 3 A V G G *) *) for hot water: max. +9 C lne-lnt_tipi-ten-mec-en_b_tc PRESSURE/TEMPERATURE APPLICATION LIMITS FOR COMPLETE PUMP p [bar] BQ 1 EGG-WA BQ 1 VGG Q 1 Q 1 EGG Q 1 Q 1 VGG 1 U 3 AEGG U 3 AVGG 1 EPDM FKM CB, CC, CN, CR, CS FKM (hot water) EPDM, FKM EPDM, FKM LNE_M_D_ot t [ C] 1

15 ErP 9/1/EC e-lne SERIES MOTORS With the Energy using Products (EuP /3/EC) and Energy related Products (ErP 9/1/EC) directives, the European Commission has established requirements for promoting the use of products with low power consumption. The various products considered include three-phase Hz surface motors with power outputs ranging from,7 to 37 kw, also when integrated with other products, with characteristics as defined by the specific Regulation (EC) No 6/9 implementing the requirements of the EuP and ErP Directives which also establish the following deadlines: from kw minimum level of efficiency (IE) 16 th June 11,7 37 IE 7 th July 1,7 37 new exclusion criteria 1 ) < 7, IE 1 st January 1 IE3 7, 37 IE fitted with variable speed drive ) IE3 1 st January 17,7 37 IE fitted with variable speed drive ) 1 ) Fixed by subsequent Regulation (EU) No /1. ) IE motor can be supplied without frequency converter as the obligation to have that device is related to when motor works and not when is placed on the market. Short-circuit squirrel-cage motor, enclosed construction with external ventilation (TEFC). Rated power from 1,1 to 37 kw for -pole range and from, to 9 kw for -pole range. IP protection degree. Insulation class 1 (F). Standard three-phase surface motors,7 kw supplied as IE3. IE efficiency level according to EN 63-3:9 and IEC :1 (,7 kw). Electrical performances according to EN Metric cable gland according to EN 6. Single-phase version: - V Hz Built-in automatic reset overload protection up to 1, kw. For higher powers the protection must be provided by the user. Three-phase version: -/38-1 V Hz for power up to 3 kw. 38-1/66-69 V Hz for power above 3 kw. Overload protection to be provided by the user. PTC included as standard only for WEG motors (one per phase, 1 C). Maximum ambient temperature: C. LNEE SERIES SINGLE-PHASE MOTORS AT Hz, POLES INPUT CURRENT CAPACITOR DATA FOR 3 V Hz VOLTAGE P N MOTOR TYPE In (A) Tn kw - V μf V min -1 ls / ln % cos Nm Ts/Tn Tm/Tn IEC SIZE* Construction Design 1,1 SM9RB1S/111 9R B1 6,88-6, ,89 7,7,96 3,7,6 1,7 1, SM9RB1S/11 9R B1 9,1-8,8 81, 76,1,98,1,39 1,7, PLM9B1S/1 9 B1 1,-11,6 7 8,7 8,,97 7,3,3 1,87 * R = Reduced size of motor casing as compared to shaft extension and flange. LNEE-motm-p-en_a_te 1

16 LNEE SERIES THREE-PHASE MOTORS AT Hz, POLES η ϕ V 16

17 LNES SERIES THREE-PHASE MOTORS AT Hz, POLES Efficiency η N % V 3 V V 38 V V 1 V Y 38 V Y V Y 1 V Y 66 V Y 69 V P N kw / 3/ / / 3/ / / 3/ / / 3/ / / 3/ / / 3/ / 1,1 8, 8,7 83, 8, 8, 8, 8,3 8, 81, 8, 8, 81, 8, 8, 81, 8, 8, 81, 1, 8,6 86, 8,8 8,9 86, 8,9 86, 86, 8, 8,6 86, 8, 8,6 86, 8, 8,6 86, 8,, 86, 87, 86,8 86, 86,9 8,7 86,6 86,7 8, 86, 86,7 8, 86, 86,7 8, 86, 86,7 8, 3 87, 88, 88,3 87, 88, 87, 87, 87,8 86, 87, 87,8 86, 87, 87,8 86, 87, 87,8 86, 89,1 9,1 89, 89,1 9,1 89, 89,1 9,1 89, 89,1 9,3 9, 89,6 9, 89,9 89,6 9,1 89,, 89, 89,6 88, 89, 89,6 88, 89, 89,6 88, 89, 9,3 89,9 89,7 9, 89, 89,6 89,6 88, 7, 9,6 9, 89, 9,6 9, 89, 9,6 9, 89, 9,6 91, 9, 9,8 9,8 89,6 9,7 9, 89, 11 91,3 9, 91,1 91,3 9, 91,1 91,3 9, 91,1 91,3 9, 9, 91,6 9, 91,7 91,7 9, 91,1 1 9, 9, 91, 9, 9, 91, 9, 9, 91, 9,7 93,3 9,9 93,1 93,3 9,7 9, 9, 91, 18, 9,6 93,1 9, 9,6 93,1 9, 9,6 93,1 9, 9,6 93, 93, 9,9 93,3 9,8 9,9 93,1 9, 93, 9,7 91,3 93, 9,7 91,3 93, 9,7 91,3 93, 93, 9, 93,1 93, 91,9 93, 9,7 91,3 IE 3 Year of manufacture From 11/1 Manufacturer Xylem Service Italia Srl Reg. No P N Montecchio Maggiore Vicenza - Italia kw Model 1,1 SM8B/311 PE 8 1, SM9RB/31 PE 9R, PLM9B/3 E3 9 3 PLM1RB/33 E3 1R PLM11RB/3 E3 11R, PLM13RB/3 E3 13R 7, PLM13B/37 E PLM16RB/311 E3 16R 1 PLM16B/31 E , PLM16B/318 E3 16 PLM18RB/3 E3 18R IEC SIZE* Construction Design B N. of Poles f N Hz cosϕ,79,8,8,79,8,8,8,86,88,88,8 Data for V / Hz Voltage T N ls / l N Nm Ts/T N Tm/Tn 8,31 3,63 3,9 3,9 8,8,96,31,1 8,77 7,8 3,7 3,7 7,81 9,93,6 3,9 9,13 13, 3,8,3 1, 18,1,7,11 1,, 3,3,76 9,89 3,9 3,6,9 9,1 8,6,73,3 9,81 9,9,81,3 1,9 71,1 3,6,1 Voltage U N V Y Y P N V 3 V V 38 V V 1 V 38 V V 1 V 66 V 69 V kw I N (A) 1,1,19,1,16,,39,,1,38,38 1,39 1,37 1,,6,9,1 3,1 3,17 3,18 3,1 3,18 3,19 1,8 1,8, 7,97 7,9 7,98,6,6,61,7,,7,6,6 3 11, 11, 11, 6,3 6,33 6, 6,9 6,7 6,3 3,63 3,6 13,6 13, 13, 7,87 7,7 7,7 7,8 7,6 7,61,,, 18,1 17,9 18,1 1, 1, 1, 1,6 1, 1,7 6,1 6, 7,,8,,3 1,3 1,1 1, 1, 1,1 1, 8,3 8, ,7 3, 3,9,6,,,6,, 11,9 11,7 1 7,6 6,1, 7, 6,6 6,1 7, 6,6 6,1 1,9 1,3 18, 8,3 6,7,6 33,7 3,7 3,1 3, 33, 3,7 19,6 19, 7,9 73,1 73,7,1,,6,9,,6 3,6 3, * R = Reduced size of motor casing as compared to shaft extension and flange. LNES-IE3-mott-p-en_a_te ** Operating conditions to be referred to motor only. About electric pump, refer to limits in user s manual. n N min -1 Observe the regulations and codes locally in force regarding sorted waste disposal. Operating conditions ** Altitude Above Sea Level (m) 1 T. amb min/max C ATEX -1 / No 17

18 LNES SERIES THREE-PHASE MOTORS AT Hz, POLES (from 3 to 37 kw) η ϕ V 18

19 LNEE SERIES THREE-PHASE MOTORS AT Hz, POLES P N Efficiency N % V 3 V V 38 V V Y 38 V Y V Y 1 V Y 66 V Y 69 V 1 V kw / 3/ / / 3/ / / 3/ / / 3/ / / 3/ / / 3/ /, , , ,7 8, 81,3 79,8 81,1 81, 79,1 81, 81, 78, 8, 81, 78, 8, 81, 78, 8, 81, 78, 1,1 8,9 8,7 8,7 8,3 8, 83,8 8,3 8, 8,7 8,9 8, 8,7 8,9 8, 8,7 8,9 8, 8,7 1, 86,6 87, 8,7 86,7 86,9 8, 86, 8,9 83,3 86, 8,9 83,3 86, 8,9 83,3 86, 8,9 83,3, 87,6 88,6 88,3 88, 88,8 87,9 88, 88,7 87, 87,6 88,6 87, 87,6 88,6 87, 87,6 88,6 87, 3 88, 89, 88, 88,6 88,9 87,6 88,6 88,6 86,8 88, 88,6 86,8 88, 88,6 86,8 88, 88,6 86,8 3 88,6 89,1 87,9 88,6 89,1 87,9 88,6 89,1 87,9 88,6 89, 88,9 88,6 89, 88, 88,8 89,1 87,9 IE Year of manufacture 6/11 from 11/1 P N kw Manufacturer Xylem Service Italia Srl Reg. No Montecchio Maggiore Vicenza - Italia Model IEC SIZE*, SM71B/3 71,37 SM71B/3 71,,7 SM9RB1S/3 LLM9RB1S/37 9R 9R SM9RBS/3 LLM9RBS/37 9R 9R 1,1 PLM9BS/311 E3 9 1, PLM9BS3/31 E3 9, PLM1BS3/3 E3 1 3 PLM1BS3/33 E3 1 PLM11BS3/3 E3 11 Construction Design B SPECIAL N. of Poles f N Hz cos,9,6,67,67 Data for V / Hz Voltage T N ls / l N Nm Ts/T N Tm/Tn 3,8 1,71 3,16,63 3,39,7 3,,7 3,9 3,77,,38 3,9 3,77,,38,7,78,3,77 3,31,71 6, 7,8,7 3,,68 6,9 9,89 3,9,1,78 7,7 1,,38 3,69,7 7,7 19,7,8,1,79 8,3 6,3 3,19, Voltage U N V Y Y P N V 3 V V 38 V V 1 V 38 V V 1 V 66 V 69 V kw I N (A), 1,68 1,71 1,77,97,99 1, ,37,6,3,6 1, 1,6 1, ,,98 3,3 3,1 1,7 1,7 1, ,7 3,8 3,3 3,1 1,78 1,7 1,7 1,78 1,7 1,7 1,3 1,1 1,1,61,9,6,66,6,67,6,63,6 1,3 1, 1, 6,3 6,1 6,1 3,66 3,7 3,7 3,6 3,68 3,69,11,13, 8,19 8, 7,97,73,6,6,7,6,6,71, , 11, 11, 6,66 6,6 6,67 6,63 6,9 6,63 3,83 3,81 1,8 1,6 1, 8, 8, 8,36 8, 8,3 8,19,8,7 n N min Observe the regulations and codes locally in force regarding sorted waste disposal. Operating conditions ** Altitude T. amb ATEX Above Sea min/max Level (m) C 1-1 / No * R = Reduced size of motor casing as compared to shaft extension and flange. LNEE-IE3-mott-p-en_a_te ** Operating conditions to be referred to motor only. About electric pump, refer to limits in user s manual. 19

20 LNES SERIES THREE-PHASE MOTORS AT Hz, POLES P N Efficiency η N V 3 V V 38 V V Y 38 V Y V Y 1 V Y 66 V Y 69 V 1 V kw / 3/ / / 3/ / / 3/ / / 3/ / / 3/ / / 3/ /, ,7 8, 81,3 79,8 81,1 81, 79,1 81, 81, 78, 8, 81, 78, 8, 81, 78, 8, 81, 78, 1,1 8,9 8,7 8,7 8,3 8, 83,8 8,3 8 8,7 8,9 8 8,7 8,9 8 8,7 8,9 8 8,7 1, 86,6 87 8,7 86,7 86,9 8, 86, 8,9 83,3 86, 8,9 83,3 86, 8,9 83,3 86, 8,9 83,3, 87,6 88,6 88,3 88, 88,8 87,9 88, 88,7 87, 87,6 88,6 87, 87,6 88,6 87, 87,6 88,6 87, 3 88, 89, 88, 88,6 88,9 87,6 88,6 88,6 86,8 88, 88,6 86,8 88, 88,6 86,8 88, 88,6 86,8 88,6 89,1 87,9 88,6 89,1 87,9 88,6 89,1 87,9 88,6 89, 88,9 88,6 89, 88, 88,8 89,1 87,9 3, 9, 9,9 89,7 9, 9,9 89,7 9, 9,9 89,7 9, 91, 9, 9,9 91,1 9, 9,9 9,9 89,7 7, 9, 91, 9, 9, 91, 9, 9, 91, 9, 9, 91, 91,1 9,7 91,3 9,8 9,9 91, 9, 11 91, 9, 91, 91, 9, 91, 91, 9, 91, 91, 9, 9, 91,9 9, 9 91,9 9, 91, 1 9, 9, 9,8 9, 9, 9,8 9, 9, 9,8 9, 93, 9,7 9, 9,7 91,8 9, 9, 9,8 % IE Year of manufacture 11 from 11/1 P N kw Manufacturer Xylem Service Italia Srl Reg. No Montecchio Maggiore Vicenza - Italia Model IEC SIZE Construction Design N. of Poles, SM8B/3 8,67 3,9 3,77,,38,7 LLM8B/37 8,7,78,3,77 3,31 1,1 PLM9B/311 E3 9,71 6, 7,8,7 3, 1, PLM9B/31 E3 9,68 6,9 9,89 3,9,1, PLM1B/3 E3 1,78 7,7 1,,38 3,69 3 PLM1B/33 E3 1 B,7 7,7 19,7,8,1 PLM11B/3 E3 11,79 8,3 6,3 3,19,, PLM13B/3 E3 13,76 7,6 3,9,8 3,6 7, PLM13B/37 E3 13,79 7,7 9,1,69 3,7 11 PLM16B/311 E3 16,81 7,19 71,, 3,6 1 PLM16B/31 E3 16,77 8,3 97,,97 3,99 f N Hz cosϕ Data for V / Hz Voltage ls / l N T N Nm Ts/T N Tm/Tn Voltage U N Operating conditions ** V Y Y Altitude T. amb ATEX P N V 3 V V 38 V V 1 V 38 V V 1 V 66 V 69 V n N Above Sea min/max I N (A) min -1 Level (m) C kw,,98 3,3 3,1 1,7 1,7 1, ,7 3,8 3,3 3,1 1,78 1,7 1,7 1,78 1,7 1,7 1,3 1,1 1,1,61,9,6,66,6,67,6,63,6 1,3 1, 1, 6,3 6,1 6,1 3,66 3,7 3,7 3,6 3,68 3,69,11,13, 8,19 8, 7,97,73,6,6,7,6,6,71, , 11, 11, 6,66 6,6 6,67 6,63 6,9 6,63 3,83 3,81 1,8 1,6 1, 8, 8, 8,36 8, 8,3 8,19,8,7,, 19,7 19, 11,6 11, 11, 11,7 11, 11, 6,7 6,6 7, 6,6 6,1,8 1, 1,1 1,9 1, 1, 1,1 8,9 8, ,3 37,3 37,,1 1,8 1,7 1,9 1, 1,3 1,6 1,3 1 1,8,,7 9,9 3, 3, 3, 3,7 31, 17,6 17, / + No ** Operating conditions to be referred to motor only. About electric pump, refer to limits in user s manual. LNES-IE3-mott1-p-en_a_te Observe the regulations and codes locally in force regarding sorted waste disposal.

21 LNES SERIES THREE-PHASE MOTORS AT Hz, POLES (from 18, to 9 kw) η ϕ V 1

22 MOTOR NOISE The tables below show the mean sound pressure levels (Lp) measured at 1 meter s distance in a free field according to the A curve (ISO 168 standard). The noise values are measured with idling Hz motor with a tolerance of 3 db (A). LNEE, LNES MOTORS POLES Hz LNEE, LNES MOTORS POLES Hz LNE_mott-en_b_tr

23 ErP 9/1/EC e-lne SERIES PUMPS Over last decade the European Commission with the Energy Efficiency Plan pushed the European Parliament and the Council to adopt specific measures to the purpose of reducing energy consumption and further negative environmental impacts. Through the Directives /3/EC, energy-using products (EuP), and 9/1/EC, energy-related products (ErP) a framework for ecodesign requirements was established. The Commission Regulation (EU) No 7/1 has implemented two directives with regard to ecodesign requirements for some types of clean water pumps placed on the market and put into service inside EU zone as self-alone units or integrated in other products. For end-suction close-coupled in-line pumps (ESCCi for the Regulation) the efficiency assessment refers to: just the pump and not the pump and motor assembly (electric or combustion); pumps with just one impeller; pumps with a nominal pressure PN not higher than 16 bar (16 kpa); pumps with a minimum nominal flow not less than 6 m 3 /h; pumps with a maximum nominal power at the shaft not higher than 1 kw; pumps designed to operate at a speed of 9 min- 1 (for electric pumps this means Hz -pole electric motors) and with a head not greater than 1 metres; pumps designed to operate at a speed of 1 min- 1 (for electric pumps this means Hz -pole electric motors) and with a head not greater than 9 metres; use with clean water at a temperature ranging from -1 C to 1 C (the test is performed with cold water at a temperature not higher than C). According to the definitions established in the Regulation LNEE and LNES versions correspond to the end-suction close-coupled in-line pump. This regulation states that water pumps shall have a minimum index MEI coming from a dedicated formula which considers hydraulic efficiency values at best efficiency point (BEP), 7 % of the flow at BEP (Part load PL) and 11 % of the flow at BEP (Over load OL). The Regulation also establishes the following deadlines. from minimum efficiency index (MEI) 1 st January 13 MEI,1 1 st January 1 MEI, Regulation (EU) n. 7/1 Annex II point (Product information requirements) 1) Minimum efficiency index: see MEI values in specific tables on following page. ) The benchmark for most efficient water pumps is MEI,7. 3) Year of manufacture: 1. ) Manufacturer: Xylem Service Italia Srl - Reg. No Montecchio Maggiore, Vicenza, Italy. ) Product type: see the PUMP TYPE column in the tables in the Hydraulic performance section. 6) Hydraulic pump efficiency with trimmed impeller: see ηp and ØT columns in the tables in the Hydraulic performance section. 7) Pump performance curves, including the performance curve: see the Operating Characteristics graphs in the following pages. 8) The efficiency of a pump with a trimmed impeller is usually lower than that of a pump with the full impeller diameter. The trimming of the impeller will adapt the pump to a fixed duty point, leading to reduced energy consumption. The minimum efficiency index (MEI) is based on the full impeller diameter. 9) The operation of this water pump with variable duty points may be more efficient and economic when controlled, for example, by the use of a variable speed drive that matches the pump duty to the system. 1) Information relevant for disassembly, recycling or disposal at end-of-life: observe the current laws and by-laws governing sorted waste disposal. Consult the product operating manual. 11) Designed for use below 1 C only : note not applicable to these products. 1) Designed for use above 1 C only : note not applicable to these products. 13) Specific instructions for pumps as per points 11 and 1: not applicable to these products. 1) Information on benchmark efficiency is available at : (Ecodesign section). 1) The benchmark efficiency graphs with MEI =.7 and MEI =. are available at or (refer to ESCCi 1 rpm ). 3

24 e-lne SERIES MINIMUM EFFICIENCY INDEX (MEI) Lne-MEI-en_d_sc

25 e-lne SERIES HYDRAULIC PERFORMANCE RANGE AT Hz, POLES LNE ~ 9 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] Q [US gpm] H [ft] H [m] Q [m 3 /h] Q [l/s] A36_B_CH

26 e-lne,, 6 SERIES HYDRAULIC PERFORMANCE TABLE AT Hz, POLES η η η 6

27 e-lne 8, 1 SERIES HYDRAULIC PERFORMANCE TABLE AT Hz, POLES η η 7

28 e-lne SERIES HYDRAULIC PERFORMANCE RANGE AT Hz, POLES LNE ~ 1 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] Q [US gpm] 3 - H [m] Q [m 3 /h] ,6, Q [l/s] H [ft] A37_B_CH A37_A_CH 8

29 e-lne,, 6 SERIES HYDRAULIC PERFORMANCE RANGE AT Hz, POLES η η η 9

30 e-lne 8, 1 SERIES HYDRAULIC PERFORMANCE RANGE AT Hz, POLES η η 3

31 e-lne 1, 1,, SERIES HYDRAULIC PERFORMANCE TABLE AT Hz, POLES η η η η 31

32 e-lne SERIES IDENTIFICATION OF GRAPH Max efficiency η [%] REF TYPE DESCRIPTION 1 3 Full Diameter impeller operating range Trimmed diameter impeller operating range ISO efficiency curves 3

33 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE -1 ~ 9 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] η[%] Q [US gpm] 9 8 H[m] H [ft] 1 7-1/11-1/1-1/3-1/ NPSH[m] 1-1/3 8 6 NPSH [ft] 3 Pp[kW] 1-1/11-1/1-1/ -1/3 3 1 P P [HP] Q [m 3 /h] Q [l/s] LNE-1_P_C_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 33

34 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE -16 ~ 9 [rpm] ISO 996:1 - Grade 3B Q 18 [Imp gpm] Q [US gpm] 6 8 η[%] H[m] / -16/3-16/ -16/ 6 H [ft] NPSH[m] / NPSH [ft] Pp[kW] / 6-16/ -16/3-16/ Q [m 3 /h] Q [l/s] P P [HP] LNE-16_P_D_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 3

35 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE - ~ 9 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] H[m] Q [US gpm] 6 η[%] /7 -/ 3. -/ -/ H [ft] NPSH[m] -/7 1 1 NPSH[ft] /7 8 Pp[kW] -/3 -/ -/ 6 Pp[HP] Q 36 [m 3 /h] Q [l/s] LNE-_P_D_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 3

36 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE - ~ 9 [rpm] ISO 996:1 - Grade 3B Q 16 [Imp gpm] Q [US gpm] η[%] /1 H[m]. -/11 -/** -/7 1 H [ft] NPSH[m] -/1 1 NPSH [ft] /1 -/11 1 Pp[kW] 8 -/** -/7 1 P P [HP] Q [m 3 /h] Q [l/s] **= 9. kw (/9) LNEE, **= 11 kw (/11A) LNES LNE-_P_D_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 36

37 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE -1 ~ 9 [rpm] ISO 996:1 - Grade 3B 1 1 Q [Imp gpm] Q [US gpm] η[%] H[m] / 7 6 H [ft] /3 3-1/1-1/ NPSH[m] -1/ 1 NPSH [ft] Pp[kW] / -1/3 3-1/ -1/ Q 6 [m 3 /h] Q [l/s] P P [HP] LNE-1_P_C_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 37

38 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE -16 ~ 9 [rpm] ISO 996:1 - Grade 3B 1 1 Q [Imp gpm] Q [US gpm] η[%] H[m] /7 8 H [ft] / -16/ /3 1 NPSH[m] 8-16/7 3 1 NPSH [ft] /7 8 Pp[kW] -16/ -16/ -16/3 6 P P [HP] Q 7 [m 3 /h] Q [l/s] LNE-16_P_D_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 38

39 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE - ~ 9 [rpm] ISO 996:1 - Grade 3B 1 1 Q [Imp gpm] Q [US gpm] η[%] H[m] /11 -/** -/7 -/ H [ft] 1 1 NPSH[m] 8 -/ NPSH [ft] Pp[kW] /11 1 -/** 1 -/7 8 -/ Q 7 [m 3 /h] Q [l/s] **= 9. kw (/9) LNEE, **= 11 kw (/11A) LNES P P [HP] LNE-_P_D_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 39

40 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE - ~ 9 [rpm] ISO 996:1 - Grade 3B 1 1 Q [Imp gpm] Q [US 3gpm] η[%] / H[m] /18 -/1 -/11 1 H [ft] 3 -/** / NPSH[m] 1 NPSH [ft] -/18 -/ 3 Pp[kW] 1 1 -/** -/11 -/1 1 P P [HP] Q 8 [m 3 /h] 1 1 Q [l/s] **= 9. kw (/9) LNEE, **= 11 kw (/11A) LNES LNE-_P_D_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec.

41 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE 6-1 ~ 9 [rpm] ISO 996:1 - Grade 3B η[%] Q [Imp gpm] Q [US gpm] H[m] /7 H [ft] / 6-1/ 8 6-1/3 6 NPSH[m] 6-1/7 1 1 NPSH [ft] /7 8 Pp[kW] 6-1/3 6-1/ 6-1/ 6 P P [HP] Q 9 [m 3 /h] 1 1 Q [l/s] LNE6-1_P_C_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 1

42 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE 6-16 ~ 9 [rpm] ISO 996:1 - Grade 3B 1 3 Q [Imp gpm] Q [US gpm] η[%] H[m] H [ft] / /** 6-16/7 6-16/ NPSH[m] / NPSH [ft] /11 1 Pp[kW] / 6-16/7 6-16/** 1 P P [HP] Q 1 [m 3 /h] Q [l/s] **= 9. kw (/9) LNEE, **= 11 kw (/11A) LNES LNE6-16_P_D_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec.

43 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE 6- ~ 9 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] Q [US gpm] η[%] H[m] /18 6-/1 6-/ H [ft] 6-/** 1 1 NPSH[m] 8 6-/ NPSH [ft] 1 6-/18 Pp[kW] 1 6-/1 6-/11 6-/** 1 1 P P [HP] Q 1 [m 3 /h] Q [l/s] **= 9. kw (/9) LNEE, **= 11 kw (/11A) LNES LNE6-_P_C_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 3

44 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE 6- ~ 9 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] Q [US gpm] η[%] 3 H[m] / / 6-/18 6-/1 1 H [ft] NPSH[m] 1 6-/3 3 1 NPSH [ft] Pp[kW] /3 3 6-/ 6-/18 6-/ Q 1 [m 3 /h] Q [l/s] P P [HP] LNE6-_P_C_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec.

45 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE 8-16 ~ 9 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] H[m] η[%] / /1 8-16/ /** 8-16/7 8-16/ Q [US gpm] H [ft] NPSH[m] / NPSH[ft] /18 Pp[kW] /1 8-16/ /** 8-16/7 8-16/ 1 1 Pp[HP] Q [m 3 /h] 1 3 Q [l/s] **= 9. kw (/9) LNEE, **= 11 kw (/11A) LNES LNE8-16_P_C_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec.

46 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE 8- ~ 9 [rpm] ISO 996:1 - Grade 3B η[%] Q [Imp gpm] Q [US gpm] H[m] /3 8-/ 8-/18 8-/1 8-/ H [ft] 1 NPSH[m] /3 3 1 NPSH [ft] 3 Pp[kW] /3 3 8-/ 8-/18 8-/1 8-/ Q 18 [m 3 /h] Q [l/s] P P [HP] LNE8-_P_C_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 6

47 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE 8- ~ 9 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] Q [US gpm] η[%] 7 H[m] /37 8-/3 1 H [ft] 3 8-/ 1 1 NPSH[m] /37 8-/3 8-/ NPSH [ft] Pp[kW] 8-/ 3 P P [HP] Q [m 3 /h] Q [l/s] LNE8-_P_C_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 7

48 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE 1-16 ~ 9 [rpm] ISO 996:1 - Grade 3B η[%] Q [Imp gpm] Q [US gpm] H[m] H [ft] / 1-16/ /1 1-16/11 3 NPSH[m] / 8 6 NPSH [ft] Pp[kW] / 1-16/ /1 1-16/ P P [HP] 1 1 Q 3 [m 3 /h] Q [l/s] LNE1-16_P_B_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 8

49 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE 1- ~ 9 [rpm] ISO 996:1 - Grade 3B Q[Imp gpm] Q [US gpm] η[%] H[m] H [ft] 1 1-/37 1-/3 1-/ NPSH[m] /37 1-/ NPSH [ft] Pp[kW] 1 1-/3 1-/ Q 3 [m 3 /h] Q [l/s] 3 P P [HP] LNE1-_P_C_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 9

50 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE 1- ~ 9 [rpm] ISO 996:1 - Grade 3B Q 9 [Imp gpm] η[%] Q [US gpm] 1 H[m] 3 1-/37 1 H [ft] 1 NPSH[m] /37 NPSH [ft] 3 1-/37 Pp[kW] Q [m 3 /h] Q [l/s] 3 P P [HP] LNE1-_P_B_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec.

51 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE -1 ~ 1 [rpm] ISO 996:1 - Grade 3B Q 7[Imp gpm] Q [US gpm] η[%] H[m] H [ft] /3-1/ -1/A -1/B 3 NPSH[m] 1-1/3 8 6 NPSH [ft]...3-1/3. Pp[kW]..1-1/ -1/A -1/B.3..1 P P [HP] Q [m 3 /h] 1 3 Q [l/s] LNE-1_P_C_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 1

52 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE -16 ~ 1 [rpm] ISO 996:1 - Grade 3B Q [Imp 9 gpm] Q [US gpm] η[%] H[m] / -16/ / /7 1 1 H [ft] NPSH[m] 6-16/7 1 1 NPSH [ft] Pp[kW]. -16/7-16/ -16/3.6. P P [HP]. -16/ Q [m 3 /h] Q [l/s] LNE-16_P_D_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec.

53 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE - ~ 1 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] H[m] Q [US gpm] η[%] /11 -/7 3 H [ft] -/A -/ 1 3 NPSH[m] 1 -/ NPSH [ft] Pp[kW] /11 -/7 -/ -/A P P [HP] Q [m 3 /h] Q [l/s] LNE-_P_D_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 3

54 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE - ~ 1 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] Q [US gpm] 8 η[%] H[m] / -/1 -/** -/* 3 H [ft] 1 6 NPSH[m] -/ 1 1 NPSH [ft]. -/ 1. -/1 Pp[kW] 1. -/* -/** 1 P P [HP] Q 8 [m 3 /h] Q [l/s] **= 1.1 kw (/11) LNES, **= 1. kw (/1A) LNEE; *= 1.1 kw (/11A) LNES, *= 1. kw (/1B) LNEE LNE-_P_D_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec.

55 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE -1 ~ 1 [rpm] ISO 996:1 - Grade 3B η[%] Q [Imp gpm] Q [US gpm] H[m] 3 1 H [ft] / -1/A -1/ -1/3 3 NPSH[m] 1-1/ 8 6 NPSH [ft].. -1/.6. Pp[kW] /3-1/ -1/A Q 3 [m 3 /h] Q [l/s]..3. P P [HP] LNE-1_P_C_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec.

56 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE -16 ~ 1 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] Q [US gpm] η[%] 3 3 H[m] /3 8-16/ / / H [ft] 6 NPSH[m] -16/ NPSH [ft] / Pp[kW] / /. -16/ Q 3 [m 3 /h] Q [l/s] P P [HP] LNE-16_P_D_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 6

57 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE - ~ 1 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] Q [US gpm] η[%] 8.1 H[m] /1 -/11 -/11A -/7 3 1 H [ft] 6 NPSH[m] -/1 1 1 NPSH [ft] /1 -/11 1. Pp[kW]. -/11A -/7 1.. P P [HP] Q 3 [m 3 /h] Q [l/s] LNE-_P_D_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 7

58 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE - ~ 1 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] η[%] Q [US gpm] /3 -/ H[m] /A -/1 -/** 3 H [ft] /3 6 NPSH[m] 1..6 NPSH [ft]. 3 Pp[kW] 1 -/** -/3 -/ -/A -/1 3 1 P P [HP] Q 3 [m 3 /h] Q [l/s] **= 1.1 kw (/11) LNES, **= 1. kw (/1A) LNEE LNE-_P_D_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 8

59 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE 6-1 ~ 1 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] H[m] Q [US gpm] η[%] H [ft] 1 6-1/3 6-1/11 6-1/7 6-1/ NPSH[m] / NPSH [ft] /11 1. Pp[kW] /3 6-1/ 6-1/7. P P [HP] Q [m 3 /h] Q [l/s] LNE6-1_P_C_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 9

60 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE 6-16 ~ 1 [rpm] ISO 996:1 - Grade 3B 1 1 Q [Imp gpm] H[m] Q [US gpm] η[%] / / /11A 6-16/ H [ft] /1 1 NPSH[m] 1 NPSH [ft] 1. Pp[kW] /1 6-16/ /11A 6-16/ Q 6 [m 3 /h] Q [l/s] P P [HP] LNE6-16_P_D_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 6

61 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE 6- ~ 1 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] Q [US gpm] η[%] / 3 H[m] /A H [ft] 6 6-/1 6-/** 1 NPSH[m] / 1 NPSH [ft].. 6-/ 3. Pp[kW] /** 6-/1 6-/A. 1. P P [HP] Q [m 3 /h] Q [l/s] **= 1.1 kw (/11) LNES, **= 1. kw (/1A) LNEE LNE6-_P_D_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 61

62 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE 6- ~ 1 [rpm] ISO 996:1 - Grade 3B 1 1 Q [Imp gpm] Q [US gpm] η[%] / H[m] /3 6-/ 6-/A 3 H [ft] NPSH[m] 6-/ 1 1 NPSH [ft] 3 6-/ Pp[kW] 1 6-/ 6-/A 6-/3 3 1 P P [HP] Q 7 [m 3 /h] Q [l/s] LNE6-_P_C_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 6

63 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE 8-16 ~ 1 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] H[m] η[%] /1 8-16/** 8-16/* 8-16/ 8-16/A Q [US gpm] H [ft] 3 1 NPSH[m] / NPSH [ft] Pp[kW] /1 8-16/** 8-16/* 8-16/ 8-16/A P P [HP] Q 11 [m 3 /h] Q [l/s] **= 1.1 kw (/11) LNES, **= 1. kw (/1A) LNEE; *= 1.1 kw (/11A) LNES, *= 1. kw (/1B) LNEE LNE8-16_P_C_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 63

64 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE 8- ~ 1 [rpm] ISO 996:1 - Grade 3B Q 3 [Imp gpm] H[m] Q [US gpm] η[%] / 8-/3 8-/ 8-/A 8-/1 3 1 H [ft] 6 NPSH[m] 8-/ 1 1 NPSH [ft] 3 8-/ Pp[kW] 8-/3 8-/ 8-/A 3 P P [HP] 1 8-/ Q 1 [m 3 /h] 1 1 Q [l/s] LNE8-_P_C_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 6

65 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE 8- ~ 1 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] H[m] Q [US gpm] η[%] /7 8-/ 8-/A 8-/ 8-/ H [ft] 1 8-/7 3 NPSH[m] 1 NPSH [ft] /7 8 Pp[kW] 8-/ 8-/A 8-/ 6 P P [HP] 8-/ Q 1 [m 3 /h] Q [l/s] LNE8-_P_C_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 6

66 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE 8-31 ~ 1 [rpm] ISO 996:1 - Grade 3B η [%] /1 8-31/ / /7 8-31/ / / / LNE8-31_P_B_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 66

67 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE 1-16 ~ 1 [rpm] ISO 996:1 - Grade 3B 1 3 Q [Imp gpm] Q 7 [US gpm] η[%] 3 3 H[m] /3 1-16/ 1-16/A 1-16/1 1 1 H [ft] 6 NPSH[m] 1-16/3 1 1 NPSH [ft] /3 1-16/ 3 Pp[kW] /A 1-16/1 1 P P [HP] Q 16 [m 3 /h] Q [l/s] LNE1-16_P_B_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 67

68 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE 1- ~ 1 [rpm] ISO 996:1 - Grade 3B H[m] η[%] Q [Imp gpm] Q [US gpm] 3 H [ft] 6 1-/ 1-/A 1-/ 1-/ NPSH[m] 1-/ 1 NPSH [ft] 6 8 Pp[kW] / 6 1-/A 1-/ 1-/ Q 18 [m 3 /h] Q [l/s] P P [HP] LNE1-_P_C_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 68

69 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE 1- ~ 1 [rpm] ISO 996:1 - Grade 3B 1 3 Q [Imp gpm] Q 7 [US gpm] η[%] /11 H[m] /7 1-/ 1-/A 3 H [ft] 1 6 NPSH[m] 1-/ NPSH [ft] Pp[kW] / /7 8 1-/ 6 1-/A Q 16 [m 3 /h] Q [l/s] P P [HP] LNE1-_P_B_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 69

70 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE 1-31 ~ 1 [rpm] ISO 996:1 - Grade 3B η [%] / 1-31/ / / / / 1-31/ /1 1-31/ LNE1-31_P_B_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 7

71 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE 1-16 ~ 1 [rpm] ISO 996:1 - Grade 3B η [%] / 1-16/ / / / /3 1-16/ LNE1-16_P_B_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 71

72 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE 1- ~ 1 [rpm] ISO 996:1 - Grade 3B η [%] /7 6 1-/ 1-/ /7 1-/ LNE1-_P_B_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 7

73 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE 1- ~ 1 [rpm] ISO 996:1 - Grade 3B η [%] / /7 1-/ /11 1-/ LNE1-_P_B_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 73

74 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE 1-31 ~ 1 [rpm] ISO 996:1 - Grade 3B η [%] / 1-31/ /1 1-31/ / / / 1-31/ / LNE1-31_P_B_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 7

75 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE 1- ~ 1 [rpm] ISO 996:1 - Grade 3B η [%] /11 1-/7 1-/ / / / 1-/ LNE1-_P_B_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 7

76 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE 1- ~ 1 [rpm] ISO 996:1 - Grade 3B η [%] / /11 1-/ / / LNE1-_P_B_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 76

77 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE 1-31 ~ 1 [rpm] ISO 996:1 - Grade 3B η [%] / / / 1-31/ / / / The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 1-31/ / 3 1 LNE1-31_P_B_CH 77

78 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE - ~ 1 [rpm] ISO 996:1 - Grade 3B η [%] /3 -/ -/18 -/ /1 -/ /3 1 -/ -/18 -/ LNE-_P_B_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 78

79 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE -31 ~ 1 [rpm] ISO 996:1 - Grade 3B η [%] / -31/ /37-31/ /3-31/ / -31/ -31/37-31/ LNE-31_P_B_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 79

80 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE - ~ 1 [rpm] ISO 996:1 - Grade 3B η [%] /9 -/7 -/ / -/ /9 -/7 -/ LNE-_P_B_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 8

81 e-lne SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNE -31 ~ 1 [rpm] ISO 996:1 - Grade 3B η [%] /7-31/ -31/ 6-31/37-31/ /3-31/ /7-31/ -31/ -31/37-31/ LNE-31_P_B_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 81

82 8

83 DIMENSIONS AND WEIGHTS 83

84 LNEE,, 6, 8, 1 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES 8

85 LNEE,, 6, 8, 1 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES LNEE--1_p-en_b_td 8

86 LNEE,, 6, 8, 1 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES 86

87 LNEE,, 6, 8, 1 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES LNEE--1_p-en_c_td 87

88 LNES,, 6 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES 88

89 LNES,, 6 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES LNES---6_p-en_b_td 89

90 LNES,, 6 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES 9

91 LNES,, 6 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES LNES---6_p-en_c_td 91

92 LNES 8, 1 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES 9

93 LNES 8, 1 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES LNES-8-1_p-en_b_td 93

94 LNES 8, 1 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES 9

95 LNES 8, 1 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES LNES-8-1_p-en_d_td 9

96 LNES 1, 1,, SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES e f DN D TYPE A (base optional) AD optional mounting direction PM1 M1 PM x h h1 n1 m1 m **) DN S L b1 b TYPE B (base included) h h1 Ø1 L e 3 38 C C b E 3 6 TYPE C (base included) h h1 Ø L AD b AD b C C Connections 9 DN D 1 DN D PM1 / PM 1/" 1/" ee Flange 1/" 1/" E EN19-, PN 16 *) PM1..Pressure gauge connector PM..Pressure gauge connector E...Drain *)...Value C and D may vary from standard **)..Mounting base for Type A optional 8kg (see accessories section) L b1 DN df K D DN D K C df L x x x x8 LNES-EN_C_DD 96

97 LNES 1, 1,, SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES LNES-p-en_d_td 97

98 98

99 LNE..H (e-lne with HYDROVAR ) 99

100 LNE..H SERIES (e-lne WITH HYDROVAR ) Background and context For all pumping needs in commercial or residential building and in industry applications, the demand for intelligent pumping systems is constantly growing. Controlled systems offer many advantages: reduced operating costs for the lifetime of the pump, lower environmental impact, longer lifetime of piping systems and networks. For this reason, Lowara has developed the LNE..H: an intelligent pumping system which assures high level performance with energy consumption tailored to the system s demand. Benefits of e-lne with HYDROVAR Saving: LNE..H transforms the LNE pumps into variable speed intelligent pumping systems. Thanks to the HYDROVAR, the speed of each pump varies so as to maintain a constant flow, a constant pressure, or a differential pressure. In doing so, at any point in time, the pump only receives the energy required. This in turns allows for considerable savings, especially for systems that have varying loads throughout the day. Key Features of the Hydrovar No need for additional pressure sensors: The LNE..H is fitted with a pressure transmitter or differential pressure transmitters, depending on the application. No need for special pumps or motors. No need for bypass or safety systems: The LNE..H will immediately switch off when demand drops to zero or when it exceeds maximum pump capacity; thus making installation of additional safety devices unnecessary. Anti-condensation device: The LNE..H is fitted with anti-condensation devices which switch on when the pump is in standby in order to prevent condensation forming in the unit. Easy installation and space-saving: LNE..H saves time and space during installation. The Hydrovar is delivered already mounted on the motor (for models up to kw). The hydrovar is kept cool by the motor fan and does not require a control panel. In order to function, only fuses on the supply line are needed (Check your local electrical installation regulations). A wall-mounted HYDROVAR version is available for higher power outputs (up to kw). Standard motors: LNE..H models are fitted with threephase standard TEFC motors with insulation class 1 (F). Identification code: LNE..H models are identified by the letter H in the standard identification code of the e-lne product range. Example: LNEEH-/11/PVCS H = with integrated HYDROVAR 1

101 LNE..H SERIES (e-lne WITH HYDROVAR ) The basic function of the HYDROVAR device is to control the pump to meet the system demands. HYDROVAR performs these functions by: 1) Measuring the system pressure or flow via a transmitter mounted on the pump s delivery side. ) Calculating the motor speed to maintain the correct flow or pressure. 3) Sending out a signal to the pump to start the motor, increase speed, decrease speed or stop. ) In the case of multiple pump installations, HYDROVAR will automatically provide for the cyclic changeover of the pumps starting sequence. Control for constant pressure In addition to these basic functions, HYDROVAR can perform controls only manageable by the most advanced computerized control systems. Some examples are: Stop the pump(s) at zero demand. Stop the pump(s) in case of water failure on the suction side (protection against dry running). Stop the pump if the required delivery exceeds the pump s capacity (protection against cavitation caused by excessive demand), or automatically switch on the next pump in a multiple series. Protect the pump and motor from over-voltage, undervoltage, overload, and earth fault. Vary the pump speed: acceleration and deceleration time. Compensate for increased flow resistance at high flow rates. Conduct automatic tests at set intervals. Monitor the converter and motor operating hours. Display all functions on an LCD in different languages (Italian, English, French, German, Spanish, Portuguese, Dutch). Send a signal to a remote control system which is proportional to the pressure and frequency. Communicate with another HYDROVAR or control system via an RS 8 interface. Control to match a system curve Control for constant flow Control according to an external signal 11

102 e-lne..h SERIES LIST OF MODELS AT Hz, POLES SIZE kw VERSION SIZE kw LNEH.. LNEEH LNESH LNEH.. LNEEH LNESH -1/11 1,1 8-16/7 7, -1/1 1, 8-16/9 9, - -1/, 8-16/11A / / / /1 1-16/ 8-16/18 18, -16/, 8-/18 18, - -/ 8-/ - -/, 1-16/ /7 7, 1-16/1 1 -/9 9, /18 18, -/11A / -/ / - -/1 1-1/1 1, -1/, -1/3 3-1/ -16/ -16/, -16/7 7, -/7 7, -/9 9, - -/11A / / /1 1 -/18 18, -/ 6-1/ / 6-1/, 6-1/7 7, 6-16/7 7, 6-16/9 9, /11A / / /1 1 6-/18 18, 6-/18 18, 6-/ = Available LNEH_models-p-en_a_sc LEGEND VERSION LNEEH : Extended shaft with HYDROVAR (single version). LNESH : Stub shaft with HYDROVAR (single version). 1

103 e-lne..h SERIES LIST OF MODELS AT Hz, POLES = Available LNEH_models-p-en_b_sc 13

104 LNEEH,, 6, 8 1 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES 1

105 LNEEH,, 6, 8 1 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES PUMP TYPE DIMENSIONS (mm) WEIGHT LNEEH.. B H L x ØF DND DNS e h1 h AD b1 p max kg -1/11/S , -1/1/S , -1//P , -1/3/P , -16/3/P , -16//P , -16//P ,1 -//P , -//P ,1 -/7/P ,1 -/9/P ,1 -/11/P ,1 -/1/P /1/S , -1//P , -1/3/P , -1//P , -16//P , -16//P ,1-16/7/P ,1 -/7/P ,1 -/9/P ,1 -/11/P ,1 -/11/P ,1 -/1/P /18/P //P /3/P , 6-1//P , 6-1//P ,1 6-1/7/P ,1 6-16/7/P ,1 6-16/9/P ,1 6-16/11/P ,1 6-/11/P , 37, ,1 6-/1/P , 37, /18/P , 37, /18/P , 37, //P , 37, /7/P ,1 8-16/9/P ,1 8-16/11/P ,1 8-16/1/P /18/P /11/P ,1 1-16/1/P /18/P //P NOTE: Pumps supplied with flanges according to EN 19- as standard. For flanges dimensions see drawing. LNEEH--1_p_a_td 1

106 LNEEH,, 6, 8 1 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES 16

107 LNEEH,, 6, 8 1 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES PUMP TYPE DIMENSIONS (mm) WEIGHT LNEEH.. B H L x ØF DND DNS e h1 h AD b1 p max kg -1/B/S , -1/A/S , -1//S , -1/3/S , -16/3/S , -16//S , -16/7/X , -//S , -/7/X , -/11/P , -/1A/P , -/1/P , -//P , -1/A/S , -1//S , -1/3/S , -1//S , -16//S , -16/7/X , -16/11/P , -/11A/P , -/11/P , -/1/P , -/1/P , -/A/P , -//P , -/3/P , 6-1/3/S , 6-1//S , 6-1/7/X , 6-1/11/P , 6-16/11A/P , 6-16/11/P , 6-16/1/P , 6-/1/P , 37, , 6-/A/P , 37, , 6-//P , 37, , 6-//P , 37, , 6-/3/P , 37, , 6-//P , 37, , 8-16/1B/P , 8-16/1A/P , 8-16/1/P , 8-16/A/P , 8-16//P , 1-16/1/P , 1-16/A/P , 1-16//P , 1-16/3/P , NOTE: Pumps supplied with flanges according to EN 19- as standard. For flanges dimensions see drawing. LNEEH--1_p-en_a_td 17

108 LNESH,, 6 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES 18

109 LNESH,, 6 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES LNESH---6_p-en_a_td 19

110 LNESH,, 6 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES 11

111 LNESH,, 6 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES PUMP TYPE DIMENSIONS (mm) WEIGHT LNESH.. B H L x ØF DND DNS e f h1 h AD b1 p max kg -16//S , -16/7/X , -//S , -/7/X , -/11/P , -/11/P , -/1/P , -//P , -1//S , -16//S , -16/7/X , -16/11/P , -/11A/P , -/11/P , -/1/P , -/1/P , -/A/P , -//P , -/3/P , 6-1//S , 6-1/7/X , 6-1/11/P , 6-16/11A/P , 6-16/11/P , 6-16/1/P , 6-/1/P , 37, , 6-/A/P , 37, , 6-//P , 37, , 6-//P , 37, , 6-/3/P , 37, , 6-//P , 37, , NOTE: Pumps supplied with flanges according to EN 19- as standard. For flanges dimensions see drawing. LNESH---6_p-en_b_td 111

112 LNESH 8, 1 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES 11

113 LNESH 8, 1 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES LNESH-8-1_p-en_b_td 113

114 LNESH 8, 1 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES 11

115 LNESH 8, 1 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES LNESH-8-1_p-en_d_td 11

116 LNESH 1, 1, SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES 116

117 LNESH 1, 1, SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES LNESH-p-en_d_td 117

118 118

119 ACCESSORIES 119

120 LNE SERIES ROUND THREADED COUNTERFLANGES KIT ACCORDING TO EN 19-1 CODE DIMENSIONS (mm) HOLES DN KIT ø C ø A B ø D H ø F N PN Rp 1½ Rp Rp ½ Rp Rp Lne-Lnt-ctf-tonde-f-en_a_td LNE SERIES ROUND WELD COUNTERFLANGES KIT ACCORDING TO EN 19-1 CODE DIMENSIONS (mm) HOLES DN KIT ø C ø A B ø D ø F N PN , , , , , , Lne-Lnt-ctf-tonde-s-en_a_td 1

121 LNE,, 6, 8, 1 SERIES MOUNTING BASE KIT CODE KIT: LNE 1, 1 SERIES MOUNTING BASE KIT Ø Ø7 Ø LNES MOUNTING BASE KIT PUMP TYPE CODE STANDARD OPTION 1-16//P X 1-16/3/P X 1-16//P X 1-//P X 1-/7/P X 1-/7/P X 1-/11/P 1-31/1/P 1-31/18/W 1-31//W 1-31/3/W 1-//P 1-/7/P 1-/11/P 1-/11/P 1-/1/P 1-31/18/W 1-31//W 1-31/3/W 7366 X X X X X X X X X X X X X 1-31/37/W X LNES-BASE-EN_B_DD 11

122 LNE,, 6, 8, 1 SERIES BRACKETS KIT DIMENSIONI STAFFE SERIE LNE CODE PUMP TYPE SHAPE DIMENSIONS (mm) KIT -POLE -POLE A m m1 n n LNEE -1 / LNEE -16 LNEE -1 / LNEE -16 LNES -1 / LNES -16 A LNEE - / LNEE - LNEE - / LNEE - LNES - / LNES - LNES - / LNES - A LNEE -1 / LNEE -16 LNEE -1 / LNEE -16 LNES -1 / LNES -16 A LNEE - / LNEE - LNEE - / LNEE - LNES - / LNES - LNES - / LNES - A LNEE 6-1 / LNEE 6-16 LNEE 6-1 / LNEE 6-16 LNES 6-1 / LNES 6-16 LNES 6-16 A LNEE 6- / LNEE 6- LNEE 6- / LNEE 6- LNES 6- / LNES 6- LNES 6- / LNES 6- A LNEE 8-1 / LNEE 8-16 LNEE 8-1 LNES 8-1 / LNES 8-16 LNES 8-1 B LNEE 8- LNEE 8- / LNEE 8- LNES 8- LNES 8- / LNES 8- B LNEE 1-16 LNEE 1-16 LNES 1-16 LNES 1-16 B LNEE 1- LNEE 1- / LNEE 1- LNES 1- LNES 1- / LNES 1- B LNE_staffe-en_a_td 1

123 REPORTS AND DECLARATIONS 13

124 REPORTS AND DECLARATIONS i) Test reports a) Factory Test Report (not available for all pump types; contact Customer Service in advance) - Test report compiled at the end of the assembly line, including flow-head performance test (ISO 996:1 Grade 3B) and tightness test. b) Audit Test Report - Test report for electric pumps compiled in the test room, comprising flow-head-pump input-pump efficiency performance test (ISO 996:1 Grade 3B) c) NPSH Test Report - Test report for electric pumps compiled in the test room, comprising flow-npsh performance test (ISO 996:1 Grade 3B) d) Noise Test Report - Report indicating sound pressure and power measurements (EN ISO 361, EN ISO 113, EN ISO 871) e) Vibration Test Report (unavailable for submerged or submergible pumps) - Report indicating vibration measurements (ISO ) ii) Declaration of product conformity with the technical requirements indicated in the order a) EN 1: - type.1 - does not include test results on supplied or similar products. b) EN 1: - type. - includes test results (materials certificates) on similar products. iii) Issue of a further EC Declaration of Conformity, - in addition to the one accompanying the product, it comprises references to European law and the main technical standards (e.g.: MD 6//EC, EMCD /18/EC, ErP 9/1/EC). N.B.: if the request is made after receipt of the product, communicate the code (name) and serial number (date + progressive number). iv) Manufacturer s declaration of conformity - relative to one of more types of products without indicating specific codes and serial numbers. v) Other certificates and/or documentation on request - subject to availability or feasibility. vi) Duplication of certificates and/or documentation on request - subject to availability or feasibility. 1

125 TECHNICAL APPENDIX 1

126 NPSH The minimum operating values that can be reached at the pump suction end are limited by the onset of cavitation. Cavitation is the formation of vapour-filled cavities within liquids where the pressure is locally reduced to a critical value, or where the local pressure is equal to, or just below the vapour pressure of the liquid. The vapour-filled cavities flow with the current and when they reach a higher pressure area the vapour contained in the cavities condenses. The cavities collide, generating pressure waves that are transmitted to the walls. These, being subjected to stress cycles, gradually become deformed and yield due to fatigue. This phenomenon, characterized by a metallic noise produced by the hammering on the pipe walls, is called incipient cavitation. The damage caused by cavitation may be magnified by electrochemical corrosion and a local rise in temperature due to the plastic deformation of the walls. The materials that offer the highest resistance to heat and corrosion are alloy steels, especially austenitic steel. The conditions that trigger cavitation may be assessed by calculating the total net suction head, referred to in technical literature with the acronym NPSH (Net Positive Suction Head). The NPSH represents the total energy (expressed in m.) of the liquid measured at suction under conditions of incipient cavitation, excluding the vapour pressure (expressed in m.) that the liquid has at the pump inlet. To find the static height hz at which to install the machine under safe conditions, the following formula must be verified: hp + hz (NPSHr +.) + hf + hpv where: hp is the absolute pressure applied to the free liquid surface in the suction tank, expressed in m. of liquid; hp is the quotient between the barometric pressure and the specific weight of the liquid. hz is the suction lift between the pump axis and the free liquid surface in the suction tank, expressed in m.; hz is negative when the liquid level is lower than the pump axis. hf is the flow resistance in the suction line and its accessories, such as: fittings, foot valve, gate valve, elbows, etc. hpv is the vapour pressure of the liquid at the operating temperature, expressed in m. of liquid. hpv is the quotient between the Pv vapour pressure and the liquid s specific weight., is the safety factor. 1 The maximum possible suction head for installation depends on the value of the atmospheric pressure (i.e. the elevation above sea level at which the pump is installed) and the temperature of the liquid. To help the user, with reference to water temperature ( C) and to the elevation above sea level, the following tables show the drop in hydraulic pressure head in relation to the elevation above sea level, and the suction loss in relation to temperature. Water temperature ( C) Suction loss (m),,7,, 7, 1, 1, Elevation above sea level (m) Suction loss (m), 1,1 1,6,,7 3,3 Friction loss is shown in the tables Flow Resistance of this catalogue. To reduce it to a minimum, especially in cases of high suction head (over - m.) or within the operating limits with high flow rates, we recommend using a suction line having a larger diameter than that of the pump s suction port. It is always a good idea to position the pump as close as possible to the liquid to be pumped. Make the following calculation: Liquid: water at ~1 C γ = 1 kg/dm 3 Flow rate required: m 3 /h Head for required delivery: 7 m. Suction lift: 3, m. The selection is an 33SV3G7T pump whose NPSH required value is, at m 3 /h, of m. For water at 1 C hp = Pa / γ = 1,33m, hpv = Pv / γ =,17m (,171 bar) The Hf flow resistance in the suction line with foot valves is ~ 1, m. By substituting the parameters in formula 1 with the numeric values above, we have: 1,33 + (-3,) ( +,) + 1, +,17 from which we have: 6,8 > 3,9 The relation is therefore verified. TECHNICAL APPENDIX 16

127 VAPOUR PRESSURE VAPOUR PRESSURE ps AND ρ DENSITY OF WATER TABLE t T ps ρ t T ps ρ t T ps ρ C K bar kg/dm 3 C K bar kg/dm 3 C K bar kg/dm 3 73,1,611, ,1,171, ,1 1,98,99 1 7,1,67, ,1,1611, ,1,11,91 7,1,76, ,1,17313, ,1,, ,1,78, ,1,1817, ,1,3933, ,1,813 1, 9 33,1,1916, ,1,3,936 78,1,87 1, 6 333,1,199, ,1,713, ,1,93 1, 61 33,1,86,986 13,1,867, ,1,11, ,1,18, ,1 3,1, ,1,17, ,1,86, ,1 3,3,99 9 8,1,117, ,1,391, ,1 3,1, ,1,17, ,1,1, ,1 3,61, ,1,131, ,1,61, ,1,1,91 1 8,1,11, ,1,733, ,1,33, ,1,197, ,1,86, ,1 6,181, ,1,197, ,1,98, ,1 7,8,9 1 88,1,17, ,1,3116, ,1 7,9, ,1,1817, ,1,33, ,1 8,9, ,1,1936, ,1,3396, ,1 1,7, ,1,6, ,1,33, ,1 11,33, ,1,196, ,1,3696, ,1 1,1,876 93,1,337, ,1,38, ,1 13,987,87 1 9,1,8, ,1,19,971 73,1 1,,867 9,1,6, ,1,189,973 78,1 17,3, ,1,88, ,1,36, ,1 19,77,88 97,1,98, ,1,7, ,1 1,6,867 98,1,3166, ,1,736, ,1 3,198, ,1,336, ,1,931,971 98,1,1, ,1,36, ,1,133,97 3 3,1 7,976, ,1,3778, ,1,3, ,1 3,63,8 9 3,1,, ,1,7, ,1 33,78, ,1,1, ,1,78,968 18,1 36,3, ,1,91, ,1,611,9678 3,1 39,776, ,1,73, ,1,69,9671 8,1 3,6, ,1,9, ,1,69, ,1 6,93, ,1,318, ,1,679, ,1,877, ,1,6, ,1,711,96 7 3,1,8, ,1,9, ,1,781,96 7 8,1 9,96, ,1,67, ,1,761, ,1 6,, ,1,66, ,1,789, ,1 69,186, ,1,6991, ,1,816, ,1 7,61, ,1,737, ,1,83, ,1 8,37, ,1,7777, ,1,8769, ,1 8,97,71 31,1,8198, ,1,99, ,1 9,1, ,1,9639, ,1,93, ,1 98,7, ,1,91, ,1,9776, ,1 1,61, ,1,98, ,1 1,133, ,1 11,89, ,1,186, ,1 1,878, ,1 1,6,61 7 3,1,161, ,1 1,1668, ,1 18,63,6 8 31,1,1116, ,1 1,, ,1 16,,61 9 3,1,11736, ,1 1,339,9 3 63,1 16,3,73 33,1,133, ,1 1,37, ,1 186,7,7 1 3,1,1961, ,1 1,316, ,1 1,,18 3,1,13613, ,1 1,636,976 37,1 67,3 1,, ,1,193, ,1 1,76,96 37,1,1, ,1 1,868,9 G-at_npsh_b_sc 17 TECHNICAL APPENDIX

128 TABLE OF FLOW RESISTANCE IN 1 m OF STRAIGHT CAST IRON PIPELINE (HAZEN-WILLIAMS FORMULA C=1) FLOW RATE NOMINAL DIAMETER in mm and inches m 3 /h l/min /" 3/" 1" 1 1/" 1 1/" 1/" 3" " " 6" 7" 8" 1" 1" 1" 16",6 1 v,9,3,3,1,13 hr 16 3,9 1,33,,13 The hr values must be multiplied by:,9 1 v 1,,8,1,31,,71 for galvanized or painted steel pipes hr 33,9 8,3,8,8,9, for stainless steel or copper pipes 1, v 1,89 1,6,68,1,7,17,7 for PVC or PE pipes hr 7,7 1,1,79 1,,9,16 1, v,36 1,33,8,,33,1 hr 87, 1, 7,,18,73, 1,8 3 v,83 1,9 1,,6,, hr 1 3,1 1,1 3, 1,3,3,1 3 v 3,3 1,86 1,19,73,6,3 hr 16, 13,,6 1,37,6, v,1 1,36,83,3,3, hr 1, 17,3,19 1,7,9,16 3 v,6 1,7 1,,66,, hr 77, 6,1 7,8,6,89, 3,6 6 v 3,18, 1,,8,1,3 hr 18 36,6 11, 3,71 1,,3, 7 v 3,7,38 1,,93,9,3 hr 1 8,7 1,6,93 1,66,6,8 8 v,,7 1,66 1,6,68, hr 18 6,3 18,7 6,3,13,9, v v 3,6 3, 1,87,7 1,19 1,33,76,8,,,3,33 hr hr 77, 9,1 3,3 8,3 7,8 9,,6 3,,7,9,7,33 7, 1 v,,9 1,66 1,6,63,1 hr 1,8 1,,86 1,36,9 9 1 v 3,11 1,99 1,7,7,,3 hr 9,9, 6,8 1,9,69,3 1, 17 v 3,63,3 1,9,88,8,37 hr 79,7 6,9 9,7,3,9,31 1 v,1,6 1,7 1,1,66, hr 1 3, 11,6 3,3 1,18, v v,18 3,98 3,3,,1 1,1 1,6 1,,83,6,3,1,3 hr hr 1 7,8,,6 17, 6,8,89,9 1,78,8,6,8, v v v,31 6,63,1 3,, 3,,1,1 1,99 1,33 1,66 1,7,8 1,6,8,,68,7,38,7, hr hr hr ,6 1,8 63,,7 11,66 17,6 8,98, 6,1 3,3 1,3,16 1,,8,73,,,3, 7 v,9 3,,3 1,9,9,66,9 hr 118 3,8 11,9,3 1,36,6, v v 6,79 7,6,,,6,99 1,7 1,91 1,9 1,,7,8,,6 hr hr ,,3 1,3 19,,16 6,1 1,7,16,7,89,3, 6 1 v,3 3,3,1 1,36,9,69,3 hr 63, 3,1 7,79,63 1,8,1,7 7 1 v 6,8,1,6 1,7 1,18,87,66 hr 96, 3,9 11,8 3,97 1,63,77, 9 1 v 7,,98 3,18, 1, 1,,8 hr 13 8,9 16,,7,9 1,8, v 8,79,81 3,7,38 1,6 1,1,93 hr 179 6,1 1,9 7, 3, 1,,7 1 v 6,63,,7 1,89 1,39 1,6,68 hr 83,3 8,1 9,8 3,9 1,8,96,3 1 v 8,9,31 3,,36 1,73 1,33,8 hr 16, 1,3,89,78 1,, v 6,37,8,83,8 1,9 1,,71 hr 9,,1 8,6 3,9,3,69,8 1 3 v 7,3,76 3,3,3 1,86 1,19,83 hr 79,1 6,7 11,,18,71,91,38 v 8,9, 3,77,77,1 1,36,9 hr 11 3, 1,1 6,6 3,6 1,17,8 3 v 6,79,7 3,7,6 1,7 1,18 hr 1,6 1, 1,,3 1,77, v 8,1,66,16 3,18, 1, hr 7,3 9,8 1,1 7,33,7 1, 7 v 6,61,8 3,7,38 1,6 1,1 hr 39,6 18,7 9,7 3,9 1,3, v v 7, 8,9, 6,,,78,7 3,6 1,89,1 1,39 1,6 1,19 hr hr,7 63, 3,9 9,8 1,9 1,,1, 1,73,16,8 1,,3 6 1 G-at-pct-en_a_th v 6,93,31 3,,36 1,73 1,33 hr 36, 18,9 6,36,6 1,,6 hr = flow resistance for 1 m of straight pipeline (m) V = water speed (m/s) TECHNICAL APPENDIX 18

129 FLOW RESISTANCE TABLE OF FLOW RESISTANCE IN BENDS, VALVES AND GATES The flow resistance is calculated using the equivalent pipeline length method according to the table below: ACCESSORY TYPE Equivalent pipeline length (m) bend,,,,,6,6,9 1,1 1, 1,9,,8 9 bend,,6,9 1,1 1,3 1,,1,6 3, 3,9,7,8 9 smooth bend,,,,6,9 1,1 1,3 1,7 1,9,8 3, 3,9 Union tee or cross 1,1 1,3 1,7,1,6 3,,3,3 6, 7, 1,7 1,8 Gate - - -,,,,,,6,9 1,1 1,3 Non return valve 1,1 1, 1,9, 3, 3,,7,9 7, 9,6 11,8 13,9 DN G-a-pcv-en_a_th The table is valid for the Hazen Williams coefficient C=1 (cast iron pipework); for steel pipework, multiply the values by 1,1; for stainless steel, copper and coated cast iron pipework, multiply the values by 1,8; When the equivalent pipeline length has been determined, the flow resistance is obtained from the table of flow resistance. The values given are guideline values which are bound to vary slightly according to the model, especially for gate valves and non-return valves, for which it is a good idea to check the values supplied by manufacturers. 19 TECHNICAL APPENDIX

130 VOLUMETRIC CAPACITY Litres Cubic metres Cubic feet Cubic feet Imperial gallon U.S. gallon per minute per hour per hour per minute per minute per minute l/min m 3 /h ft 3 /h ft 3 /min Imp. gal/min US gal/min 1,,6,1189,33,,6 16,6667 1, 3,317,886 3,666,9,719,83 1,,167,138,17 8,3168 1,699 6, 1, 6,88 7,8,61,78 9,636,16 1, 1,9 3,78,71 8,8,1337,837 1, PRESSURE AND HEAD Newton per kilo Pascal bar Pound force per Metre Millimetre of square metre square inch of water mercury N/m kpa bar psi m H O mm Hg 1,,1 1 x 1-1, x 1-1, x 1 -,7 1, 1,,1,1,1 7,6 1 x 1 1, 1, 1,38 1,197 7, ,77 6,898,689 1,,731 1, ,6 9,867,981 1,3 1, 73,61 133,3,1333,13,193,136 1, LENGTH Millimetre Centimetre Metre Inch Foot Yard VOLUME mm cm m in ft yd 1,,1,1,39,33,11 1, 1,,1,3937,38,19 1, 1, 1, 39,371 3,88 1,936,,, 1,,833,78 3,8 3,8,38 1, 1,, , 91,,91 36, 3, 1, Cubic metre Litre Millilitre Imperial gallon U.S. gallon Cubic foot m 3 L ml imp. gal. US gal. ft 3 1, 1, 1 x ,969 6,17 3,317,1 1, 1,,,6,33 1 x 1-6,1 1,, x 1 -,6 x 1-3,3 x 1 -,,61 6,87 1, 1,9,16,38 3, ,1,837 1,,1337,83 8, ,866 6,88 7,8 1, TEMPERATURE Water Kelvin Celsius Fahrenheit K C F icing 73,1, 3, boiling 373,1 1, 1, F = C C = ( F 3) 9 G-at_pp-en_b_sc TECHNICAL APPENDIX 13

131 FURTHER PRODUCT SELECTION AND DOCUMENTATION Xylect TM Xylect TM is pump solution selection software with an extensive online database of product information across the entire Lowara range of pumps and related products, with multiple search options and helpful project management facilities. The system holds up-to-date product information on thousands of products and accessories. The possibility to search by applications and the detailed information output given makes it easy to make the optimal selection without having detailed knowledge about the Lowara products. The search can be made by: Application Product type Duty point Xylect TM gives a detailed output: List with search results Performance curves (flow, head, power, efficiency, NPSH) Motor data Dimensional drawings Options Data sheet printouts Document downloads incl dxf files The search by application guides users not familiar with the product range to the right choice. 131 TECHNICAL APPENDIX

132 FURTHER PRODUCT SELECTION AND DOCUMENTATION Xylect TM The detailed output makes it easy to select the optimal pump from the given alternatives. The best way to work with Xylect TM is to create a personal account. This makes it possible to: Set own standard units Create and save projects Share projects with other Xylect TM users Every user have a My Xylect space, where all projects are saved. For more information about Xylect TM please contact our sales network or visit Dimensional drawings appear on the screen and can be downloaded in dxf format. TECHNICAL APPENDIX 13

e-lnt Series Lenntech ErP 2009/125/EC 50 Hz Tel Fax

e-lnt Series Lenntech ErP 2009/125/EC 50 Hz Tel Fax Hz e-lnt Series TWIN IN-LINE ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS Lenntech info@lenntech.com Tel. +31-1-61-9 www.lenntech.com Fax. +31-1-616-89 ErP 9/1/EC Cod. 191731 Rev. C Ed./16 Xylect TM Xylect

More information

60 Hz. e-nsc Series HORIZONTAL CENTRIFUGAL ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS

60 Hz. e-nsc Series HORIZONTAL CENTRIFUGAL ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS 6 Hz e-nsc Series HORIZONTAL CENTRIFUGAL ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS Cod. 19112831 Rev. B Ed.7/217 Xylect TM Xylect TM is a pump solution software with an extensive online database of product

More information

e-nsc Series Lenntech ErP 2009/125/EC 50 Hz Tel Fax

e-nsc Series Lenntech ErP 2009/125/EC 50 Hz Tel Fax Hz e-nsc Series HORIZONTAL CENTRIFUGAL ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS ErP 9/1/EC Lenntech info@lenntech.com Tel. +31-1-61-9 www.lenntech.com Fax. +31-1-616-89 Cod. 19191 Rev. F Ed.3/16 Xylect

More information

e-sh Series Lenntech 60 Hz Tel Fax

e-sh Series Lenntech 60 Hz Tel Fax Hz e-sh Series HORIZONTAL CENTRIFUGAL ELECTRIC PUMPS ACCORDING TO EN 733 MADE IN AISI 31 STAINLESS STEEL AND EQUIPPED WITH IE3 MOTORS Lenntech info@lenntech.com Tel. +31-1-1-9 www.lenntech.com Fax. +31-1-1-89

More information

e-mp Series MPA, MPR, MPD, MPV Lenntech 50 Hz Tel Fax

e-mp Series MPA, MPR, MPD, MPV Lenntech 50 Hz Tel Fax Hz e-mp Series MPA, MPR, MPD, MPV HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 199 Lenntech info@lenntech.com Tel. +31-1-1-9 www.lenntech.com Fax. +31-1-1-9 Cod. 1911 Rev. A Ed.3/17 Xylect TM Xylect

More information

CMA - B - C - D - CMR

CMA - B - C - D - CMR Cast iron self-priming electric pumps. APPLICATIONS Pressure boosting domestic plants Small-scale irrigation Moving non-aggressive liquids for civil and industrial use Washing plants Washing vehicles CMA-B-C-D

More information

50/60 Hz. ecocirc XL and XLplus. high efficiency WET ROTOR circulators. ErP 2009/125/EC

50/60 Hz. ecocirc XL and XLplus. high efficiency WET ROTOR circulators. ErP 2009/125/EC / Hz ecocirc XL and XLplus high efficiency WET ROTOR circulators FOR COMMERCIAL HEATING AND COOLING applications ErP 9/1/EC Cod. 1971 Rev. C Ed.11/1 Lowara, ecocirc, Xylect are trademarks of Xylem Inc.

More information

Contents. Identification LHC. Horizontal split case pumps. Type key. Identification Type key

Contents. Identification LHC. Horizontal split case pumps. Type key. Identification Type key Contents dentification Type key Product data ntroduction Applications Features and benefits Performance range pole pole pole Construction Sectional drawing Construction features Test pressure Operating

More information

SVH with HYDROVAR (HVL range)

SVH with HYDROVAR (HVL range) SVH with HYDROVAR (HVL range) SVH-HVL Rev. B Ed.9/1 (EN) SVH SERIES (e-sv WITH HYDROVAR) Background and context For all pumping needs in commercial or residential building and in industry applications,

More information

50 Hz n= 2900 rpm. Standardised EN 733 centrifugal pumps INSTALLATION AND USE. PERFORMANCE RANGE Flow rate up to 6000 l/min (360 m³/h) Head up to 98 m

50 Hz n= 2900 rpm. Standardised EN 733 centrifugal pumps INSTALLATION AND USE. PERFORMANCE RANGE Flow rate up to 6000 l/min (360 m³/h) Head up to 98 m F Standardised EN 733 centrifugal pumps Hz n= 9 rpm Clean water Industrial use PERFORMNCE RNGE Flow rate up to (3 ) Head up to 9 m PPLICTION LIMITS Manometric suction lift up to 7 m Liquid temperature

More information

EVOTRON WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA APPLICATIONS ADVANTAGES

EVOTRON WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA APPLICATIONS ADVANTAGES TECNICAL DATA EVOTRON Operating range: from, -, m3/h with head of up to metres. Pumped liquid temperature range: from - C to + C. Working pressure: bar ( kpa). Protection class: IP X. Insulation class:

More information

DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, 3x400V AP-, AKP- and AEP- series, threaded G1/2 G1 ¼ LOREM IPSUM JE ZULT MAAR 60 HZ.

DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, 3x400V AP-, AKP- and AEP- series, threaded G1/2 G1 ¼ LOREM IPSUM JE ZULT MAAR 60 HZ. LOREM IPSUM JE ZULT MAAR HZ m Head m/s m/s m/s m/s m/s Ø m Ø Ø Ø Ø l/s Flow kw Shaft power P Ø m/h Ø 9 Ø Ø kw 9 Total input power P Ø DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, xv AP-, AKP- and AEP-

More information

SINGLE IMPELLER CENTRIFUGAL ELECTRIC PUMPS in cast iron

SINGLE IMPELLER CENTRIFUGAL ELECTRIC PUMPS in cast iron Cast iron self-priming electric pumps. APPLICATIONS Pressure boosting domestic plants Small-scale irrigation Moving non-aggressive liquids for civil and industrial use Washing plants Washing vehicles CMA-B-C-D

More information

LES. Single-stage end-suction pumps Identification Type key

LES. Single-stage end-suction pumps Identification Type key Contents Singlestage endsuction pumps Identification Type key Product data Introduction Applications Features and benefits Performance range pole pole 6 pole Construction Sectional drawing Construction

More information

Single Phase Motors Technical Datasheets

Single Phase Motors Technical Datasheets Single Phase Motors Technical Datasheets EN A dynamic, strong and ambitious Group: Orange1 Holding is an international renown Group, one of the most important European manufacturers of single-phase and

More information

PiB Series. PiB (Pump-in-a-Box) 4380 & 4392 Series

PiB Series. PiB (Pump-in-a-Box) 4380 & 4392 Series PiB Series PiB (Pump-in-a-Box) & 9 Series FILE NO: - DATE: July SUPERSEDES: - DATE: January 09 PiB Series Guaranteed In Stock At The Right Price! The PiB series builds on the high quality and unsurpassed

More information

Prima range. Alifter range. magnetical driven pumps in thermoplastic materials TMP TMA. centrifugal. self-priming

Prima range. Alifter range. magnetical driven pumps in thermoplastic materials TMP TMA. centrifugal. self-priming Prima range TMP centrifugal Alifter range magnetical driven pumps in thermoplastic materials TMA self-priming Prima - Alifter In this catalog Argal proposes the range of PRIMA pumps, magnetical driven,

More information

Calio-Therm NC Type Series Booklet

Calio-Therm NC Type Series Booklet High-efficiency Drinking Water Pump Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,

More information

Pneumatic Universal. Actuator MOTORIZED VALVES USE TECHNICAL FEATURES OF THE ACTUATOR. Data sheet

Pneumatic Universal. Actuator MOTORIZED VALVES USE TECHNICAL FEATURES OF THE ACTUATOR. Data sheet Data sheet. - 8 USE The motorized valve is specifically used for the interception and regulation of fluids in: systems using alternative energy industrial systems in general using hot and cold fluids automation

More information

barmesapumps.com SELF-PRIMING CENTRIFUGAL TRASH PUMP SPECIFICATIONS Series: SH8-U Suction: 8" Discharge: 8" Spherical solids handling: 3"

barmesapumps.com SELF-PRIMING CENTRIFUGAL TRASH PUMP SPECIFICATIONS Series: SH8-U Suction: 8 Discharge: 8 Spherical solids handling: 3 SELF-PRIMING CENTRIFUGAL TRASH PUMP Series: SH-U Suction: " Discharge: " Spherical solids handling: 3" SIZE BEARING - PUMP END " x " NPT, lbs., female flange. Open single ball, radial load. LIQUID TEMPERATURE

More information

Single Phase Motors Technical Datasheets

Single Phase Motors Technical Datasheets Single Phase Motors Technical Datasheets EN A dynamic, strong and ambitious Group: Orange1 Holding is an international renown Group, one of the most important European manufacturers of single-phase and

More information

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet High-efficiency Circulator Pump Rio-Eco N / Rio-Eco Z N Type Series Booklet Legal information/copyright Type Series Booklet Rio-Eco N / Rio-Eco Z N KSB Aktiengesellschaft All rights reserved. The contents

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET MAGNA, UPE Series circulator pumps Contents Product data MAGNA/UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids 3 Type key Performance

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET Series circulator pumps Contents Product data MAGNA and UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids 3 Type key Performance

More information

Standardized Chemical Pumps. Fields of Application. Designation. Design. Operating Data. Type Series Booklet /7-10 G2 CPK-H

Standardized Chemical Pumps. Fields of Application. Designation. Design. Operating Data. Type Series Booklet /7-10 G2 CPK-H Type Series Booklet.5/7-0 G CPK-H Standardized Chemical Pumps to EN 5/ISO 5/ISO 599, heatable Automation products available: Hya-Drive Hyamaster hyatronic Fields of Application CPK-H pumps are used for

More information

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

VD1 CLC. Small Valves DIN-range with a higher k v -value

VD1 CLC. Small Valves DIN-range with a higher k v -value 0 EN - Small Valves DIN-range with a higher k v -value VD CLC Valve body made of brass, mat nickel-plated DN, DN 0 and DN Internally and externally threaded (Rp / R) conforming to ISO 7- Manual knob /

More information

P U M P S. The quality standard for hydraulic efficiency and suction lift. PERIPHERAL PUMPS TEP/ TSP - SERIES 50Hz

P U M P S. The quality standard for hydraulic efficiency and suction lift. PERIPHERAL PUMPS TEP/ TSP - SERIES 50Hz P U M P S THE BENCHMARK FOR PERFORMANCE The quality standard for hydraulic efficiency and suction lift. PERIPHERAL PUMPS TEP/ TSP - SERIES 5Hz I N D E X TEP / TSP SERIES - PERIPHERAL PUMPS Page No. General

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET MAGNA, UPE Series circulator pumps Contents Product data MAGNA and UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids Type key

More information

TPH. 60Hz. Standard mode TPH 4T 2K. Code TPH 4T 2K S F A H

TPH. 60Hz. Standard mode TPH 4T 2K. Code TPH 4T 2K S F A H C US NSF/ANSI TPH Applications: The TPH Series are modernly designed with quiet and high efficient operation pumps, suitable for dependable water transfer, circulating or booster service. -Industrial circulation

More information

P U M P S. The quality standard for hydraulic efficiency and suction lift. PERIPHERAL PUMPS TEP/ TSP - SERIES 50Hz

P U M P S. The quality standard for hydraulic efficiency and suction lift. PERIPHERAL PUMPS TEP/ TSP - SERIES 50Hz P U M P S THE BENCHMARK FOR PERFORMANCE The quality standard for hydraulic efficiency and suction lift. PERIPHERAL PUMPS TEP/ TSP - SERIES 5Hz I N D E X TEP / TSP / TRP SERIES - PERIPHERAL PUMPS Page

More information

NKVE VERTICAL AXIS MULTISTAGE CENTRIFUGAL PUMPS WITH MCE/P INVERTER

NKVE VERTICAL AXIS MULTISTAGE CENTRIFUGAL PUMPS WITH MCE/P INVERTER NKVE 1-1--3--6-9 VERTICAL AIS MULTISTAGE CENTRIFUGAL PUMPS WIT MCE/P INVERTER TECNICAL DATA Operating range: fro to 118 3 /h with head up to 31 etres. Puped liquid: clean, free of solids and abrasives,

More information

ALUMINIUM CENTRIFUGAL FANS. 4 x M6 x OUTLET x M6 x 20

ALUMINIUM CENTRIFUGAL FANS. 4 x M6 x OUTLET x M6 x 20 DESCRIPTION Dutair LK-series industrial ventilators consist of a robust body made from die-cast aluminium alloy. Impellers are made of extruded aluminium. The asynchronous electric motors are maintenance

More information

ALUMINIUM CENTRIFUGAL FANS x M6 x x M6 x 16

ALUMINIUM CENTRIFUGAL FANS x M6 x x M6 x 16 LK4 DESCRIPTION Dutair LK-series industrial ventilators consist of a robust body made from die-cast aluminium alloy. Impellers are made of extruded aluminium. The asynchronous electric motors are maintenance

More information

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET Series circulator pumps Contents Product data MAGNA and UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids Type key 5 Performance

More information

SMB20, SMB30 Series. UK market only

SMB20, SMB30 Series. UK market only SMB, SMB3 Series VARIABLE SPEED BOOSTER SETS WITH e-sm DRIVE VERTICAL MULTISTAGE ELECTRIC PUMPS SERIES e-sv SMART HORIZONTAL MULTISTAGE ELECTRIC PUMPS SERIES e-hm SMART UK market only Cod. 1911 Rev. A

More information

DEBEM IM VERTICAL CENTRIFUGAL PUMPS.

DEBEM IM VERTICAL CENTRIFUGAL PUMPS. IM VERTICA CENTRIFUGA PUMPS The IM series of resin-encased vertical centrifugal pumps features high-performance pumps for fixed installations with pump immersed directly in the tank and operated by a directdrive

More information

K DOUBLE-IMPELLER DOUBLE-IMPELLER ELECTRIC PUMPS

K DOUBLE-IMPELLER DOUBLE-IMPELLER ELECTRIC PUMPS K DOUBLE-IMPELLER DOUBLE-IMPELLER ELECTRIC PUMPS ENERGY EFFICIENCY 7.5 TECHNICL DT Operating range: from,2 to 3 m 3 /h with head up to 97 metres. Pumped liquid: clean, free of solids and abrasives, non-viscous,

More information

MULTISTAGE CENTRIFUGAL PUMP TPH 2/4/8/12/25/50T. 50Hz. WALRUS PUMP ISO 9001 Certified

MULTISTAGE CENTRIFUGAL PUMP TPH 2/4/8/12/25/50T. 50Hz. WALRUS PUMP ISO 9001 Certified MULTISTAGE CENTRIFUGAL PUMP TPH /////T Hz WALRUS PUMP ISO Certified TPH Applications The WALRUS TPH Series is horizontal multistage centrifugal pump, suitable for clean water/liquid without abrasive matters.

More information

Made in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS. No. E14/A1

Made in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS. No. E14/A1 Made in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS No. E14/A1 The complete range of our products is presented in the specific catalogues: HOSE REELS CATALOGUE No. E14/A2 HOSE REELS CATALOGUE

More information

ALUMINIUM CENTRIFUGAL FANS M20 4 x M5 x 10 INLET. 4 x M5 x 12

ALUMINIUM CENTRIFUGAL FANS M20 4 x M5 x 10 INLET. 4 x M5 x 12 BCT61 DESCRIPTION Dutair BCT-series aluminium centrifugal fans with open die-cast aluminium impellers and forward curved blades are suitable for material transport and high pressure applications. The asynchronous

More information

ALUMINIUM CENTRIFUGAL FANS. 4 x M6 x 16

ALUMINIUM CENTRIFUGAL FANS. 4 x M6 x 16 DESCRIPTION Dutair BCT-series aluminium centrifugal fans with open die-cast aluminium impellers and forward curved blades are suitable for material transport and high pressure applications. The asynchronous

More information

Commercial Generator Parts Catalog. PROTEC Series

Commercial Generator Parts Catalog. PROTEC Series Commercial Generator Parts Catalog PROTEC Series YD ÁÁ ÁÁ To avoid errors or delay in filling your parts order, always give the MODEL, SPEC NO. and SERIAL NO. from the Onan nameplate. For handy reference,

More information

Description of operation...5. Installation...7. Choice and selection...8. SMB20, SMB30 Series Electric pump range and characteristics...

Description of operation...5. Installation...7. Choice and selection...8. SMB20, SMB30 Series Electric pump range and characteristics... SMB, SMB3 Series VARIABLE SPEED BOOSTER SETS WITH e-sm DRIVE VERTICAL MULTISTAGE ELECTRIC PUMPS SERIES e-sv SMART VERTICAL MULTISTAGE MONOLITHIC ELECTRIC PUMPS SERIES VM SMART HORIZONTAL MULTISTAGE ELECTRIC

More information

M O D U L E - 3A Model A10V0 Piston Pump Manual A10V0 PUMP. Features

M O D U L E - 3A Model A10V0 Piston Pump Manual A10V0 PUMP. Features T E C H N I C A L I N F O R M A T I O N M A N U A L F O R T H E A 1 0 V 0 V A R I A B L E D I S P L A C E M E N T P U M P S A10V0 PUMP Features High Efficiency through load sensing (= fuel savings) Maximum

More information

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application Type 2657...59 DN 10 up to 80 mm; Plastic; 2/2 way dvantages/benefits ntegrated pilot valves, position feed-back and limit switches available Customized system solutions with Burkert valves & sensors With

More information

DBS315 1-phase SIDE CHANNEL BLOWERS

DBS315 1-phase SIDE CHANNEL BLOWERS DBS15/ 1-phase DESCRIPTION Dutair blowers for pressure and vacuum are compact machines consisting of an electric motor with a built-on pump housing. The rotational speed of the impeller creates a high

More information

VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems

VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems 06 EN - Straight valves VDN.. Angle valves VEN.. Reverse angle valves VUN.. ACVATIX TM Radiator valves NF norm, for -pipe heating systems VDN.. VEN.. VUN.. Valve bodies made of brass, mat nickel-plated

More information

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up

More information

Variable Displacement Plug-In Motor A6VE. Series 6, for open and closed circuits Axial tapered piston, bent axis design

Variable Displacement Plug-In Motor A6VE. Series 6, for open and closed circuits Axial tapered piston, bent axis design rueninghaus Hydromatik Series 6, for open and closed circuits xial tapered piston, bent axis design Size 28...20 Nom. pressure up to 400 bar Peak pressure up to 40 bar RE 9606/0.97 RE 9606/0.97 replaces

More information

Contents. Performance Curves/Technical Data. General Data Performance Range Sectional Drawing TPH 2T TPH 4T TPH 8T TPH 12T TPH 25T TPH 50T

Contents. Performance Curves/Technical Data. General Data Performance Range Sectional Drawing TPH 2T TPH 4T TPH 8T TPH 12T TPH 25T TPH 50T Contents General Data Performance Range Sectional Drawing Performance Curves/Technical Data T T T T T 8T T T T T T T 7 9 T Series Multistage Centrifugal Pump Hz Power:.. kw Head: Up to 7M Flow: Up to L/min

More information

NM, NMD 60 Hz NM, NMD. Close Coupled Centrifugal Pumps with threaded ports

NM, NMD 60 Hz NM, NMD. Close Coupled Centrifugal Pumps with threaded ports , D z Close Coupled Centrifugal ups Construction Close-coupled, centrifugal pups; electric otor with extended sha directly connected to the pup. : single-ipeller D: with two back-to-back ipellers (with

More information

VK2 volume flow controller Overview

VK2 volume flow controller Overview New option with sound attenuator Maintenance-free VK2 volume flow controller that operates without an auxiliary power supply, for ventilation and air conditioning systems. Adjustable on site. Outstanding

More information

The FLUX F 430 with mechanical seal

The FLUX F 430 with mechanical seal The FLUX F 0 with mechanical seal Flexible coupling between motor and pump The pump must be used with many varying liquids, consequently the smallest residual left within the pump is unacceptable. You

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

High Pressure fi lters. FHB series. Maximum working pressure up to 32 MPa (320 bar) - Flow rate up to 485 l/min

High Pressure fi lters. FHB series. Maximum working pressure up to 32 MPa (320 bar) - Flow rate up to 485 l/min High Pressure fi lters FHB series Maximum working pressure up to MPa (0 bar) - Flow rate up to 8 l/min High Pressure fi lters Introduction FILTER SIZING INDEX CALCULATION CORRECTIVE FACTOR Page Introduction

More information

MSBCCL Series Asynchronous Three-Phase Brake Motors With Squirrel Cage Rotor Direct Current Brake

MSBCCL Series Asynchronous Three-Phase Brake Motors With Squirrel Cage Rotor Direct Current Brake NEMA MOTOR GOST MOTOR IEC MOTOR MSBCCL Series Asynchronous Three-Phase Motors ith Squirrel Cage Rotor Direct Current PUMP D.C. MOTOR GENERATOR MSBCCL series-enclosed construction externally ventilated-sizes

More information

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO. DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link

More information

Standardized Chemical Pumps to EN /ISO 2858/ISO 5199 sealless, with magnetic drive. Fields of Application. Designation. Design.

Standardized Chemical Pumps to EN /ISO 2858/ISO 5199 sealless, with magnetic drive. Fields of Application. Designation. Design. Type series booklet.5/- G2 Magnochem Standardized Chemical Pumps to EN 5/ISO 25/ISO 99 sealless, with magnetic drive Automation products available: PumpExpert Hyamaster hyatronic Fields of Application

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

VOLUMEC. Valve Position Indicator 5

VOLUMEC. Valve Position Indicator 5 VOLUMEC Valve Position Indicator 5 2 KRACHT CORP. 8600 S Wilkinson Way Unit A Perrysburg, OH 43551 USA P +1 419 874 1000 F +1 419 874 1006 flowmeters@krachtcorp.com www.krachtcorp.com VOLUMEC Valve Position

More information

Thermal oil. Hot Water Pumps. Fields of Application

Thermal oil. Hot Water Pumps. Fields of Application Type Series ooklet 0.50 G3 Etanorm SY Thermal Oil / Hot Water Pumps Fields of pplication Etanorm SY pumps are used in heat transfer systems (DIN 75) or in hot water circulation systems. Operating Data

More information

Direct-operated 2/2-way compact solenoid valves Type EV210A

Direct-operated 2/2-way compact solenoid valves Type EV210A Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together

More information

Return fi lters. MPI series. Maximum working pressure up to 1 MPa (10 bar) - Flow rate up to 3000 l/min

Return fi lters. MPI series. Maximum working pressure up to 1 MPa (10 bar) - Flow rate up to 3000 l/min Return fi lters series Maximum working pressure up to MPa (0 bar) Flow rate up to 000 l/min 0 Return fi lters Introduction FILTER SIZING INDEX CALCULATION CORRECTIVE FACTOR Page Introduction Calculation

More information

143 EEX gerotor pump unit. For use in oil circulation systems in gas- and dust-ex-atmospheres

143 EEX gerotor pump unit. For use in oil circulation systems in gas- and dust-ex-atmospheres 1 EEX gerotor pump unit For use in oil circulation systems in gas- and dust-ex-atmospheres Gerotor pump series 1 EEX The 1 EEX product series has been specifically designed for centralized lubrication

More information

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18 erie B. Flanged ductile iron ball valve BRanDOni made in E U R O P E Application fields WATER CONdITIONING GA EATING INdUTRY FIRE FIGTING www.brandoni.it erie B. eries B. valves are shut-off ball valves

More information

Return fi lters. FRI series. Maximum pressure up to 20 bar - Flow rate up to 1500 l/min. Return fi lters

Return fi lters. FRI series. Maximum pressure up to 20 bar - Flow rate up to 1500 l/min. Return fi lters Return fi lters FRI series Maximum pressure up to 0 bar - Flow rate up to 500 l/min 9 Return fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending by

More information

TPH Series 50Hz Multi-stage Centrifugal Pump

TPH Series 50Hz Multi-stage Centrifugal Pump WLRUS PUMP T Series Hz Multistage Centrifugal Pump ll specifications are subject to change without notice. 9 T Product data pplications Page Standard mode Page Operation conditions Page Pump construction

More information

Direct-operated 2/2-way solenoid valves Type EV210B

Direct-operated 2/2-way solenoid valves Type EV210B Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance

More information

Air Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7

Air Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7 ir ooler Industry -LN -7 / -LN -7 / F-LN -7 Symbol General The -LN -7 air cooler series can be used in all areas where either oil or water-glycol is to be cooled with air. The coolers with an axial fan

More information

Bettis RGS F-Series. Quarter-Turn Spring-Return (SR) and Double-Acting (DA) Pneumatic Actuators. Product Data Sheet RGS Rev.

Bettis RGS F-Series. Quarter-Turn Spring-Return (SR) and Double-Acting (DA) Pneumatic Actuators. Product Data Sheet RGS Rev. Bettis RGS F-Series Quarter-Turn Spring-Return (SR) and Double-Acting (DA) Pneumatic Actuators Output Torques to 500,000 in-lb (56,492 N m) Ductile Iron or Stainless-Steel Construction Temperatures from

More information

Submersible Pump in Discharge Tube. Amacan P. 60 Hz. Type Series Booklet

Submersible Pump in Discharge Tube. Amacan P. 60 Hz. Type Series Booklet Amacan P Hz Type Series Booklet Legal information/copyright Type Series Booklet Amacan P All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed

More information

IL series. Centrifugal marine IN-LINE pumps

IL series. Centrifugal marine IN-LINE pumps IL series Centrifugal marine IN-LINE pumps DESCRIPTION Vertically built centrifugal IN-LINE pumps are made with standardized DIN-22 parts, with in-line suction and discharge flanges. This arrangement requires

More information

Working pressure. 320 bar. Style T. Style D. Style S. Style B B B D.I. D.I. D.I. D.I.

Working pressure. 320 bar. Style T. Style D. Style S. Style B B B D.I. D.I. D.I. D.I. 8 FB SERIES FB Working pressure 0 bar Style S Style B Style T Style D B B B B D.I. D.I. D.I. D.I. A A A A 8 Technical data Filter body (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel

More information

TPH Series WALRUS PUMP. Multi-stage Centrifugal Pump. All specifications are subject to change without notice. 014

TPH Series WALRUS PUMP. Multi-stage Centrifugal Pump. All specifications are subject to change without notice. 014 T Series WLRUS PUMP ll specifications are subject to change without notice. Multistage entrifugal Pump T T pplications The WLRUS T Series is horizontal multistage centrifugal pump, suitable for clean water/liquid

More information

Operating Instructions for Digital Manometer. Model: MAN-SD

Operating Instructions for Digital Manometer. Model: MAN-SD Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5

More information

Power Resistor for Mounting onto a Heatsink Thick Film Technology

Power Resistor for Mounting onto a Heatsink Thick Film Technology DIMENSIONS in millimeters Power Resistor for Mounting onto a Heatsink Thick Film Technology FEATURES LPS high power: 1 W Wide resistance range: 1 Ω to 1.3 kω E24 series Non inductive Easy mounting Low

More information

2.3 T214 PTFE-LINED BUTTERFLY VALVE T 214 TECHNICAL DATA

2.3 T214 PTFE-LINED BUTTERFLY VALVE T 214 TECHNICAL DATA -INED BUTTERFY VAVE T ug type valve for corrosive and aggressive media. The patented shaft seal design ensures reliability even with high-corrosive applications. TECNICA DATA Nominal diameter: 0 Face-to-face:

More information

1.7 Z 411 WAFER TYPE BUTTERFLY VALVE Z 411 TECHNICAL DATA

1.7 Z 411 WAFER TYPE BUTTERFLY VALVE Z 411 TECHNICAL DATA WAFER TYPE BUTTERFY VAVE Z TECNICA DATA Nominal diameter: Face-to-face: EN Series (DIN T 1) ISO Series API 09 Table 1 BS 1 Series NF E 9-.1 Flange accomotion: DIN 1 PN Top flange: prepared for EN ISO Marking:

More information

SYSTEM OF ELECTRONIC PUMPS IN CASCADE Heating Air conditioning 50 Hz

SYSTEM OF ELECTRONIC PUMPS IN CASCADE Heating Air conditioning 50 Hz RANGE OF USE Flow rate: from 0 to 0 m/h Manometric head: up to mce Temperature of the fluid: from 0 to + C Ambient temperature: -0 to +0 C Max. operating pressure: bars (version SIE) bars (version LRE)

More information

SMB20 - SMB30 Series. 50 Hz

SMB20 - SMB30 Series. 50 Hz Hz SMB - SMB Series VARIABLE SPEED BOOSTER SETS WITH e-sm DRIVE VERTICAL MULTISTAGE ELECTRIC PUMPS SERIES e-sv SMART VERTICAL MULTISTAGE CLOSE-CLOUPED ELECTRIC PUMPS SERIES VM SMART HORIZONTAL MULTISTAGE

More information

14:1400 (0206) KRAL Volumeter - OMG

14:1400 (0206) KRAL Volumeter - OMG 14:1400 (0206) KRAL Volumeter - OMG OMG - Universal OMG The flowmeter for a wide range of applications Operating Conditions and Materials Flow Range: 0.1 to 7,500 l/min Max. Pressure: 250 bar Temperature

More information

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet: abc instruments international FLT5A Thermometer Land Instruments International Dronfield, S18 1DJ England Telephone: (1246) 417691 Facsimile: (1246) 41585 Email: infrared.sales@landinst.com Internet: www.landinst.com

More information

NR ROTARY RING TABLE: FLEXIBLE IN EVERY RESPECT

NR ROTARY RING TABLE: FLEXIBLE IN EVERY RESPECT NR FREELY PROGRAMMABLE ROTARY TABLES NR ROTARY RING TABLE All NR rings allow customer-specific drive motors to be connected NR ROTARY RING TABLE: FLEXIBLE IN EVERY RESPECT WHEN IT S GOT TO BE EXACT We

More information

Power Resistor for Mounting onto a Heatsink Thick Film Technology

Power Resistor for Mounting onto a Heatsink Thick Film Technology DIMENSIONS in millimeters Power Resistor for Mounting onto a Heatsink Thick Film Technology FEATURES 800 W at 85 C bottom case temperature Wide resistance range: 0.3 Ω to 900 kω E24 series Non inductive

More information

UNI EN ISO 9001:2008 UNI EN ISO 14001:2004 BS OHSAS 18001:2007 EC DIRECTIVE 2014/34/EU (ATEX) CERTIFIED MANAGEMENT SYSTEM

UNI EN ISO 9001:2008 UNI EN ISO 14001:2004 BS OHSAS 18001:2007 EC DIRECTIVE 2014/34/EU (ATEX) CERTIFIED MANAGEMENT SYSTEM EN ISM-BSM CERTIFIED Technology Made in Italy Since 1955 the Varvel Group has been making speed reducers and variators for light industry applications. Reliable partner in power transmission equipment

More information

CNA-CNB. Centrifugal fans

CNA-CNB. Centrifugal fans NA-NB entrifugal fans Product facts Product Single-inlet low-pressure fans with backward-curved blades. Use In industrial ventilation systems for uncontaminated, non-corrosive air, max. 70 º, where a low

More information

GRUNDFOS PRODUCT GUIDE. VersaFlo UP, UPS. Series 200 circulator pumps 60 Hz

GRUNDFOS PRODUCT GUIDE. VersaFlo UP, UPS. Series 200 circulator pumps 60 Hz GRUNDFOS PRODUCT GUIDE VersaFlo UP, UPS Series circulator pumps Hz Contents ission General data Terminal box modules Applications Pumped liquids Type key 5 Nameplate 5 Performance range UPS pumps UP pumps

More information

Flow rates to 750 l/min

Flow rates to 750 l/min FP Maximum pressure 0 bar Flow rates to 70 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: AISI L (FP 0-0)

More information

AC axial compact fan

AC axial compact fan ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 798 8-0 Fax +49 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA

More information

Solenoid valves 2/2-way direct-operated type EV210A

Solenoid valves 2/2-way direct-operated type EV210A MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valves 2/2-way direct-operated type EV210A EV210A covers a wide range of small, direct-operated 2/2-way solenoid valves for use in industrial machinery.

More information

ELECTRONIC WET ROTOR CIRCULATORS

ELECTRONIC WET ROTOR CIRCULATORS ELECTRONIC WET ROTOR CIRCULATORS TECNICAL DATA EVOTRON WET ROTOR ELECTRONIC CIRCULATORS Operating range: from, -, m/h with head of up to metres. Pumped liquid temperature range: from -1 C to +11 C. Working

More information

Power Resistor for Mounting onto a Heatsink Thick Film Technology

Power Resistor for Mounting onto a Heatsink Thick Film Technology Power Resistor for Mounting onto a Heatsink Thick Film Technology FEATURES LPS high power: 1100 W Wide resistance range: 1 to 1.3 k E24 series Non inductive Easy mounting Low thermal radiation of the case

More information

Submersible Pump in Discharge Tube. Amacan K. 60 Hz. Type Series Booklet

Submersible Pump in Discharge Tube. Amacan K. 60 Hz. Type Series Booklet Submersible Pump in Discharge Tube Amacan K Hz Type Series Booklet Legal information/copyright Type Series Booklet Amacan K All rights reserved. The contents provided herein must neither be distributed,

More information

Power Resistor for Mounting onto a Heatsink Thick Film Technology

Power Resistor for Mounting onto a Heatsink Thick Film Technology DIMENSIONS in millimeters Power Resistor for Mounting onto a Heatsink Thick Film Technology FEATURES 300 W at 85 C bottom case temperature Wide resistance range: 0.3 Ω to 900 kω E24 series Non inductive

More information

PARTS MANUAL 2 INCH CHIPPER/SHREDDER. SC cc SUBARU

PARTS MANUAL 2 INCH CHIPPER/SHREDDER.   SC cc SUBARU www.bearcatproducts.com 2 INCH CHIPPER/SHREDDER SC2170 170cc SUBARU PARTS MANUAL PN: 1641-00 Rev. 0011 Companion to 1509-00 Range: D01688 - Current Before You Begin DEAR ECHO BEAR CAT CUSTOMER Thank you

More information

ISEmax CAM40/CAS40. Technical Information

ISEmax CAM40/CAS40. Technical Information Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works

More information

ELECTRONIC WET ROTOR CIRCULATORS

ELECTRONIC WET ROTOR CIRCULATORS ELECTRONIC WET ROTOR CIRCULTORS Technical Sheet ELECTRONIC CIRCULTORS FOR ETING ND IR CONDITIONING SYSTEMS Energ ia e y GENERL DT compliant with the 3 and european directive ErP 9//EC (ex EuP) pplications