TPH Series WALRUS PUMP. Multi-stage Centrifugal Pump. All specifications are subject to change without notice. 014
|
|
- Charlotte Cook
- 5 years ago
- Views:
Transcription
1 T Series WLRUS PUMP ll specifications are subject to change without notice. Multistage entrifugal Pump
2 T T pplications The WLRUS T Series is horizontal multistage centrifugal pump, suitable for clean water/liquid without abrasive matters. The applications are versatile, such as pressure boosting, transfer, circulation, and machinery. Industrial circulation system Washing/cleaning system Pressure booster system Water/liquid transfer gricultural irrigation Standard mode ode S F H Nominal head (kg/cm²) Nominal flow rate (m³/hr) type Insulation class: H. ir conditioning (IP ) Flange type S: SUS (T/T/T/T) N: SUS (T/T/T/T) Standard mode Performance range Hz Hz Operation conditions mbient temperature :Max. + Liquid temperature range:+ ~ + Operating pressure:max. kg/cm² Inlet pressure:max. kg/cm² Pump construction Horizontal multistage centrifugal pump, non selfpriming, coaxial pump/motor design, impellers mounted on extended motor shaft. Main working parts made by stainless steel. Motor Enclosure protection class: IP Insulation class: F. Frequency range: / Hz Nominal speed : / rpm Voltages : ode E F U* Y* Z* U* Q Hz V /V /V V /V /V Hz V /V /V /V V /V /V /V /V Optional : hz, hz models are available on request. * The motor can be use in both / hz. T T T T T T Sectional drawing (T/T) (T /T) (T /T) Material construction No. Part name Lock Nut Sleeve(Shaft End) Water Plug Impeller Impeller Intermediate hamber Intermediate hamber Pump asing Shaft Shaft Suction hamber Sleeve Sleeve Mechanical Seal Mounted ase Mounted ase Motor Shell Gasket Flange Standard Material S series N series SUS SUS F SUS SUS SUS SUS F SUS SUS F SUS SUS SUS SUS SUS SUS SUS SUS SUS SUS SUS SUS HGSH SUS SUS SUS SUS SUS SUS SUS SUS SUS SUS SUS SUS SUS oating Steel SUS oating Steel luminum alloy Teflon+NR F SUS SUS may be replaced by SUS depended on stock availability. Options on request Terminal box position adjustable Special mechanical seal H G S H up Gasket & O Ring H: HNR (standard ) V: Viton E: EPM Rotary Face S: Si (standard ) T: Tungsten arbide Stationary Face G:arbon (standard ) S: Si T: Tungsten arbide : eramics Q(m /h)
3 T T T T P(kg/cm ) P(kg/cm ) K K K K K K T T Hz K K K K K K T T Hz..... Q(m /h).... Q(m /h) P(kW).... K K K K K K P(kW)... K K K K K K..... Q(m /h).... Q(m /h) Electrical data, /Hz Electrical data, Hz T T K T T K T T K T T K T T K T T K Z Z Z Z Z Z / / / / / / / / / / / /.. /.... /.... /.... /.... /.... /.... /.... /... /.. /.. /.. /. T T K T T K T T K T T K T T K imensions ( mm ) / / / / /.. /... /... /... /... /. Electrical data, Hz T T K T T K T T K T T K T T K T T K Outlet PF" PT /" Inlet PF" Ø. PT /" T T K T T K T T K T T K T T K T T K (mm) (mm) (mm) (mm). pcs.... pcs.
4 T T T T P(kg/cm ) P(kg/cm ) K K K K K T T Hz K K K K K T T Hz Q(m /h) Q(m /h) P(kW)... K K K K K P(kW)... K K K K K Q(m /h) Q(m /h) Electrical data, /Hz Electrical data, Hz T T K T T K T T K T T K Z Z U U U / / / / / / / / / /.. /.... /... /.. /../.. /.. /.. /.. /.. /. T T K T T K T T K T T K / / / / /... /... /... /... /... /. imensions ( mm ) Electrical data, Hz T T K T T K T T K T T K..... Outlet PF" PT /" Inlet PF¼" Ø. PT /" T T K T T K T T K T T K (mm) (mm) (mm) (mm)..... pcs pcs
5 T T T T P(kg/cm ) P(kg/cm ) K K K.K K T T Hz K K K K.K K T T Hz Q(m /h) Q(m /h) P(kW).... K K K.K K Q(m /h) P(kW)... K K K K.K K Q(m /h) Electrical data, /Hz Electrical data, Hz T T K T T.K T T K T T K T T K Z U U U U / / / / / / / / / /. /.. /.. /.. /.. /.. /.. /.. /.. /.. /. T T K T T K T T K T T K T T K / / / / /.. /... /... /.. /.. /. imensions ( mm ) Electrical data, Hz T T K T T.K T T K... Outlet PF ½" ( Or PF ") Inlet PF ½" ( Or PF ") Ø. T T K T T. K T T K T T K T T K T T K (mm) (mm) (mm) (mm).. pcs....
6 T T T T P(kg/cm ) P(kg/cm ) K K K K T T Hz K K K K K K T T Hz Q(m /h) Q(m /h) P(kW) K K K K Q(m /h) P(kW)... K K K K K K Q(m /h) Electrical data, /Hz Electrical data, Hz T T K T T K T T K T T K Z U U U / / / / / / / /.. /.... /... /.. /.. /.. /... /... /. T T K T T K T T K T T K / / / /.. /... /.. /.. /. T T K /. /. imensions ( mm ) Electrical data, Hz T T K T T K.. Outlet PF ½" ( Or PF ") Inlet PF ½" ( Or PF ") Ø. T T K T T K T T K T T K T T K T T K (mm) (mm) (mm) (mm).. pcs....
7 T T T T P(kg/cm ) P(kg/cm ) K K K K K T T Hz Q(m /h) K K K K T T Hz Q(m /h) P(kW) K K K K K P(kW) K K K K Q(m /h) Q(m /h) Electrical data, Hz Electrical data, Hz T T KF /.. /.. T T KF /. /. T T KF /.. /.. T T KF /. /. T T KF /.. /.. T T KF /. /. T T KF /.. /.. T T KF /. /. T T KF /.. /.. imensions ( mm ), Hz imensions ( mm ), Hz Outlet PF" Inlet PF" T TKF T TKF (mm) (mm).. (mm).. (mm).. Outlet PF" Inlet PF" T TKF T TKF (mm) (mm).. (mm).. (mm).. Ø T TKF T TKF T TKF Ø T TKF T TKF......
8 T T T T P(kg/cm ) P(kg/cm ) K K.K T T Hz Q(m /h) K K K T T Hz Q(m /h) P(kW) K K.K P(kW) K K K Q(m /h) Q(m /h) Electrical data, Hz Electrical data, Hz T T.KF Q /.. /.. T T KF /.. /.. T T KF /.. /.. T T KF /.. /.. T T KF Q /.. /.. T T KF /.. /.. imensions ( mm ), Hz imensions ( mm ), Hz Outlet PF" T T.KF (mm). (mm) (mm) (mm). Outlet PF" T T KF (mm). (mm) (mm) (mm). Inlet PF" T T KF T T KF.... Inlet PF" T T KF T T KF.... PT ¼" Ø PT ¼" Ø
TPH Series 50Hz Multi-stage Centrifugal Pump
WLRUS PUMP T Series Hz Multistage Centrifugal Pump ll specifications are subject to change without notice. 9 T Product data pplications Page Standard mode Page Operation conditions Page Pump construction
More informationContents. Performance Curves/Technical Data. General Data Performance Range Sectional Drawing TPH 2T TPH 4T TPH 8T TPH 12T TPH 25T TPH 50T
Contents General Data Performance Range Sectional Drawing Performance Curves/Technical Data T T T T T 8T T T T T T T 7 9 T Series Multistage Centrifugal Pump Hz Power:.. kw Head: Up to 7M Flow: Up to L/min
More informationMULTISTAGE CENTRIFUGAL PUMP TPH 2/4/8/12/25/50T. 50Hz. WALRUS PUMP ISO 9001 Certified
MULTISTAGE CENTRIFUGAL PUMP TPH /////T Hz WALRUS PUMP ISO Certified TPH Applications The WALRUS TPH Series is horizontal multistage centrifugal pump, suitable for clean water/liquid without abrasive matters.
More informationTPH. 60Hz. Standard mode TPH 4T 2K. Code TPH 4T 2K S F A H
C US NSF/ANSI TPH Applications: The TPH Series are modernly designed with quiet and high efficient operation pumps, suitable for dependable water transfer, circulating or booster service. -Industrial circulation
More information50 Hz n= 2900 rpm. Standardised EN 733 centrifugal pumps INSTALLATION AND USE. PERFORMANCE RANGE Flow rate up to 6000 l/min (360 m³/h) Head up to 98 m
F Standardised EN 733 centrifugal pumps Hz n= 9 rpm Clean water Industrial use PERFORMNCE RNGE Flow rate up to (3 ) Head up to 9 m PPLICTION LIMITS Manometric suction lift up to 7 m Liquid temperature
More informationDOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, 3x400V AP-, AKP- and AEP- series, threaded G1/2 G1 ¼ LOREM IPSUM JE ZULT MAAR 60 HZ.
LOREM IPSUM JE ZULT MAAR HZ m Head m/s m/s m/s m/s m/s Ø m Ø Ø Ø Ø l/s Flow kw Shaft power P Ø m/h Ø 9 Ø Ø kw 9 Total input power P Ø DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, xv AP-, AKP- and AEP-
More informationSINGLE IMPELLER CENTRIFUGAL ELECTRIC PUMPS in cast iron
Cast iron self-priming electric pumps. APPLICATIONS Pressure boosting domestic plants Small-scale irrigation Moving non-aggressive liquids for civil and industrial use Washing plants Washing vehicles CMA-B-C-D
More informationCMA - B - C - D - CMR
Cast iron self-priming electric pumps. APPLICATIONS Pressure boosting domestic plants Small-scale irrigation Moving non-aggressive liquids for civil and industrial use Washing plants Washing vehicles CMA-B-C-D
More informationContents. Identification LHC. Horizontal split case pumps. Type key. Identification Type key
Contents dentification Type key Product data ntroduction Applications Features and benefits Performance range pole pole pole Construction Sectional drawing Construction features Test pressure Operating
More informationbarmesapumps.com SELF-PRIMING CENTRIFUGAL TRASH PUMP SPECIFICATIONS Series: SH8-U Suction: 8" Discharge: 8" Spherical solids handling: 3"
SELF-PRIMING CENTRIFUGAL TRASH PUMP Series: SH-U Suction: " Discharge: " Spherical solids handling: 3" SIZE BEARING - PUMP END " x " NPT, lbs., female flange. Open single ball, radial load. LIQUID TEMPERATURE
More informationIL series. Centrifugal marine IN-LINE pumps
IL series Centrifugal marine IN-LINE pumps DESCRIPTION Vertically built centrifugal IN-LINE pumps are made with standardized DIN-22 parts, with in-line suction and discharge flanges. This arrangement requires
More informationPrima range. Alifter range. magnetical driven pumps in thermoplastic materials TMP TMA. centrifugal. self-priming
Prima range TMP centrifugal Alifter range magnetical driven pumps in thermoplastic materials TMA self-priming Prima - Alifter In this catalog Argal proposes the range of PRIMA pumps, magnetical driven,
More informationP U M P S. The quality standard for hydraulic efficiency and suction lift. PERIPHERAL PUMPS TEP/ TSP - SERIES 50Hz
P U M P S THE BENCHMARK FOR PERFORMANCE The quality standard for hydraulic efficiency and suction lift. PERIPHERAL PUMPS TEP/ TSP - SERIES 5Hz I N D E X TEP / TSP SERIES - PERIPHERAL PUMPS Page No. General
More informationThe FLUX F 430 with mechanical seal
The FLUX F 0 with mechanical seal Flexible coupling between motor and pump The pump must be used with many varying liquids, consequently the smallest residual left within the pump is unacceptable. You
More informationEVOTRON WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA APPLICATIONS ADVANTAGES
TECNICAL DATA EVOTRON Operating range: from, -, m3/h with head of up to metres. Pumped liquid temperature range: from - C to + C. Working pressure: bar ( kpa). Protection class: IP X. Insulation class:
More informationP U M P S. The quality standard for hydraulic efficiency and suction lift. PERIPHERAL PUMPS TEP/ TSP - SERIES 50Hz
P U M P S THE BENCHMARK FOR PERFORMANCE The quality standard for hydraulic efficiency and suction lift. PERIPHERAL PUMPS TEP/ TSP - SERIES 5Hz I N D E X TEP / TSP / TRP SERIES - PERIPHERAL PUMPS Page
More informationDEBEM IM VERTICAL CENTRIFUGAL PUMPS.
IM VERTICA CENTRIFUGA PUMPS The IM series of resin-encased vertical centrifugal pumps features high-performance pumps for fixed installations with pump immersed directly in the tank and operated by a directdrive
More informationALUMINIUM CENTRIFUGAL FANS. 4 x M6 x 16
DESCRIPTION Dutair BCT-series aluminium centrifugal fans with open die-cast aluminium impellers and forward curved blades are suitable for material transport and high pressure applications. The asynchronous
More informationALUMINIUM CENTRIFUGAL FANS M20 4 x M5 x 10 INLET. 4 x M5 x 12
BCT61 DESCRIPTION Dutair BCT-series aluminium centrifugal fans with open die-cast aluminium impellers and forward curved blades are suitable for material transport and high pressure applications. The asynchronous
More informationALUMINIUM CENTRIFUGAL FANS. 4 x M6 x OUTLET x M6 x 20
DESCRIPTION Dutair LK-series industrial ventilators consist of a robust body made from die-cast aluminium alloy. Impellers are made of extruded aluminium. The asynchronous electric motors are maintenance
More informationALUMINIUM CENTRIFUGAL FANS x M6 x x M6 x 16
LK4 DESCRIPTION Dutair LK-series industrial ventilators consist of a robust body made from die-cast aluminium alloy. Impellers are made of extruded aluminium. The asynchronous electric motors are maintenance
More informationNM, NMD 60 Hz NM, NMD. Close Coupled Centrifugal Pumps with threaded ports
, D z Close Coupled Centrifugal ups Construction Close-coupled, centrifugal pups; electric otor with extended sha directly connected to the pup. : single-ipeller D: with two back-to-back ipellers (with
More informationCalio-Therm NC Type Series Booklet
High-efficiency Drinking Water Pump Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,
More informationNKVE VERTICAL AXIS MULTISTAGE CENTRIFUGAL PUMPS WITH MCE/P INVERTER
NKVE 1-1--3--6-9 VERTICAL AIS MULTISTAGE CENTRIFUGAL PUMPS WIT MCE/P INVERTER TECNICAL DATA Operating range: fro to 118 3 /h with head up to 31 etres. Puped liquid: clean, free of solids and abrasives,
More informationDBS315 1-phase SIDE CHANNEL BLOWERS
DBS15/ 1-phase DESCRIPTION Dutair blowers for pressure and vacuum are compact machines consisting of an electric motor with a built-on pump housing. The rotational speed of the impeller creates a high
More informationLES. Single-stage end-suction pumps Identification Type key
Contents Singlestage endsuction pumps Identification Type key Product data Introduction Applications Features and benefits Performance range pole pole 6 pole Construction Sectional drawing Construction
More informationTPHIC Series Constant Pressure Inverter Control System
TPI Series onstant Inverter ontrol System Power: 0. - P : Up to kg/cm² Flow: Up to L/min : " -" pplications partment buildings, houses, villa water supply, factories, water supply systems, drinking water
More informationPiB Series. PiB (Pump-in-a-Box) 4380 & 4392 Series
PiB Series PiB (Pump-in-a-Box) & 9 Series FILE NO: - DATE: July SUPERSEDES: - DATE: January 09 PiB Series Guaranteed In Stock At The Right Price! The PiB series builds on the high quality and unsurpassed
More informationHigh-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet
High-efficiency Circulator Pump Rio-Eco N / Rio-Eco Z N Type Series Booklet Legal information/copyright Type Series Booklet Rio-Eco N / Rio-Eco Z N KSB Aktiengesellschaft All rights reserved. The contents
More information2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50
/way ball valve with electric rotary actuator, ball valve in plastic, N 50 Suitable for aggressive media High flow rate value Actuator with adjustable limit switches Visual position indicator Type 0 can
More informationDirect-operated 2/2-way solenoid valves Type EV210B
Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance
More informationHD 049 HD 069 HD 172 HD 319 HD 419 HD 619. Operating pressure up to 8700 psi Nominal flow rate up to gpm us
H i g h P re s s u re i l t e r K i t s H 049 H 069 H 172 H 319 H 419 H 619 Operating pressure up to 8700 psi Nominal flow rate up to 118.9 gpm 40.95-3us e s c r i p t i o n pplication In the high pressure
More informationISO-C Series chemical Pump
Structural drawing FEATURES ISO-C series chemical process pump, this product carried out the standard o GB/T perormance and dimension o axial suction centriugal pump (bar) ISO-C series pump take in appearance
More informationStandardized Chemical Pumps to EN /ISO 2858/ISO 5199 sealless, with magnetic drive. Fields of Application. Designation. Design.
Type series booklet.5/- G2 Magnochem Standardized Chemical Pumps to EN 5/ISO 25/ISO 99 sealless, with magnetic drive Automation products available: PumpExpert Hyamaster hyatronic Fields of Application
More informationApplication PN 16 / 40 DN Product features. Compact overall height Body shape gives optimum flow characteristic
pplication Control of gases, vapours and liquids. The modular concept of valve, multi spring actuator and digital FOXBORO/Eckardt positioner Type SRD 992 facililates trouble free expansion to allow for
More informationIts modular concept allows to build up a ball valve for any degree of automation and any kind of application
Type 2657...59 DN 10 up to 80 mm; Plastic; 2/2 way dvantages/benefits ntegrated pilot valves, position feed-back and limit switches available Customized system solutions with Burkert valves & sensors With
More informationAbsolute encoders multiturn
elektronischer electronic multiturn, Multiturn, magnetic magnetisch Sendix M66 / M68 (shaft / hollow shaft) The Sendix M6 with Energy Harvesting Technology is an electronic multiturn encoder in miniature
More informationHYDRAULIC POWER PACKS
HYDRULI POWER PKS Typical Electric Wiring Diagram (D Pack) HYDRULI POWER PKS Hydraulic Pump Hydraulic Valve Hydraulic ccessory pplication Oder ode System Power Packs SISSOR LIFT POST LIFT JP0 SISSOR LIFT
More informationConnector~Tech Providing Harsh Environment Connector
Connector~Tech www.connectortech.com.au Providing Harsh Environment Connector SOLUTIONS Tajimi TC18 series connectors are water-pro up to 30 meters in depth. Economical and highly reliable construction
More informationELMO-G Vacuum Pumps/Compressors, Range 2BH1, Three-Phase 50 Hz
ELMO- Vacuum Pumps/Compressors, Range 2BH1, Three-Phase 50 Hz Selection diagram vacuum operation Selection diagram compressor operation The performance curves are valid for pumping air at 15 C at the inlet
More informationBNA Series. PLENUM FAN with Backward Wheels
BNA Series PLENUM FAN with Backward Wheels BNA Series BNA Series Plenum Fans Backward wheels Kruger Plenum Fans are designed for air handling applications where the fan operates unhoused within a plenum.
More informationVOLUMEC. Valve Position Indicator 5
VOLUMEC Valve Position Indicator 5 2 KRACHT CORP. 8600 S Wilkinson Way Unit A Perrysburg, OH 43551 USA P +1 419 874 1000 F +1 419 874 1006 flowmeters@krachtcorp.com www.krachtcorp.com VOLUMEC Valve Position
More informationCME / CM-GE / DCME IN-LINE CONSTANT PRESSURE PUMPS. TECHNICAL DATA - CME/CM-GE single flanged
CIRCUTORS ND IN-INE UMS ENERGY EFFICIENCY Circulation pups with in-line ports, suitable for installation in heating and air conditioning, refrigeration, and doestic hot water systes. Extreely versatile
More informationOdor Removal Filter. Model Note) 1 8, , , , 3 4. Model/Free Standing Type AMF800. Model/Piping Support Type AMF Port size
dor emoval ilter Series os fficiently can remove odor in compressed air with an activated carbon element. The unit is designed for use in the area such as a clean room where odors must be avoided. Can
More informationGRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps
GRUNDFOS DATA BOOKLET MAGNA, UPE Series circulator pumps Contents Product data MAGNA/UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids 3 Type key Performance
More information50/60 Hz. ecocirc XL and XLplus. high efficiency WET ROTOR circulators. ErP 2009/125/EC
/ Hz ecocirc XL and XLplus high efficiency WET ROTOR circulators FOR COMMERCIAL HEATING AND COOLING applications ErP 9/1/EC Cod. 1971 Rev. C Ed.11/1 Lowara, ecocirc, Xylect are trademarks of Xylem Inc.
More informationBASE. Rotary limit switch. OptiOnS. FEAtuRES. CERtiFiCAtiOnS
Rotary limit switch BASE Rotary limit switch used to control and measure the movement of industrial machines. Its compact size make it suitable for use in narrow spaces. FEAtuRES It consists of a gear
More informationSpare parts list UC-M, UC-L, UC-XL
Spare parts list Contents Water inlet and tank heating Water softener Water drain, Mediamat Cyclo Circulating pump Wash + rinse; bottom Wash + rinse; top Boiler Dosage Panelling Cover plate, electrical
More informatione-mp Series MPA, MPR, MPD, MPV Lenntech 50 Hz Tel Fax
Hz e-mp Series MPA, MPR, MPD, MPV HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 199 Lenntech info@lenntech.com Tel. +31-1-1-9 www.lenntech.com Fax. +31-1-1-9 Cod. 1911 Rev. A Ed.3/17 Xylect TM Xylect
More informationStandardized Chemical Pumps. Fields of Application. Designation. Design. Operating Data. Type Series Booklet /7-10 G2 CPK-H
Type Series Booklet.5/7-0 G CPK-H Standardized Chemical Pumps to EN 5/ISO 5/ISO 599, heatable Automation products available: Hya-Drive Hyamaster hyatronic Fields of Application CPK-H pumps are used for
More informationTurbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas
Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement
More informationLKH Centrifugal Pump Description Code
LKH Centrifugal Pump Description Code Consider the information below when selecting an LKH pump. 0 LKH M S E S A B N - 00 A T S A F = Flange T = Bevel Seat STYLE LKH MODEL & PORT SIZE 0 " x ½" 0 ½" x "
More informationAir Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7
ir ooler Industry -LN -7 / -LN -7 / F-LN -7 Symbol General The -LN -7 air cooler series can be used in all areas where either oil or water-glycol is to be cooled with air. The coolers with an axial fan
More informationCONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS CADB/T-N Series
FILTERS F7 Compact heat recovery unit with cross-flow heat exchanger in 9 sizes from 500 m 3 /h to 8.350 m 3 /h. The casing is made from aluminium profile frame with double skinned 25 mm steel panels with
More informationZF Maschinenantriebe GmbH Industrial Drives. Planetary gearboxes Economy Series for Servomotors
ZF Maschinenantriebe GmbH Industrial rives Planetary gearboxes Economy Series for Servomotors 2 ZF-uoplan 2K Two-speed Gearboxes ZF-Ecolift Elevator Gearboxes ZF-Servoplan G ompact Gearbox ZF-Tiratron
More informationGRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps
GRUNDFOS DATA BOOKLET MAGNA, UPE Series circulator pumps Contents Product data MAGNA and UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids Type key
More informationCartridge Valves Technical Information. Quick reference
Quick reference Contents CPF0... 8. CP600-5... 8. CP60-5... 8. 066 handle kit... 8.5 MP06... 8.6 MP... 8.6 X05-FD0 Traction manifold... 8.9 X05-FD6 Traction manifold... 8.0 X05-FD0 Traction manifold...
More informationMade in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS. No. E14/A1
Made in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS No. E14/A1 The complete range of our products is presented in the specific catalogues: HOSE REELS CATALOGUE No. E14/A2 HOSE REELS CATALOGUE
More informationAT SERIES OFF CIRCUIT TAP CHANGERS
T SERIES OFF CIRCUIT TP CHNGERS THE CHOICE COE S.P.. PUTS ON THE RKET THE NEW T SERIES OFF CIRCUIT TP CHNGERS. T COE: THE CHOICE Comem S.p.. makes use of four main characteristics in order to be successful
More informationVK2 volume flow controller Overview
New option with sound attenuator Maintenance-free VK2 volume flow controller that operates without an auxiliary power supply, for ventilation and air conditioning systems. Adjustable on site. Outstanding
More informationNR ROTARY RING TABLE: FLEXIBLE IN EVERY RESPECT
NR FREELY PROGRAMMABLE ROTARY TABLES NR ROTARY RING TABLE All NR rings allow customer-specific drive motors to be connected NR ROTARY RING TABLE: FLEXIBLE IN EVERY RESPECT WHEN IT S GOT TO BE EXACT We
More informationSelector Switch Type 06
Seletor Swith Type 0 Compat and versatile positions multi wafer seletor swith,000 swithing yles with up to.0 Nm swithing torque Gold plated ontats: miron Roust metal housing with metal shaft Operating
More informationDirect-operated 2/2-way compact solenoid valves Type EV210A
Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together
More informationHYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC
HYGRASGARD AFF - LC AFTF - LC sensors, calibrateable, with and active passive output Quality product for HVAC sector, accuracy % r.h. The calibrateable room humidity and temperature sensor HYGRASGARD KFF
More information0T 0TS S T TS T TS T TS 0T T T T T T 6T T TS 6T 6TS T TS 6T 6TS 6T 6TS 6T 6TS Frame.. 6. 6 6... 6.... B 6 6... A..... 0..0... 6.... 6.....06 6.66.. 6.0.....6 0... C 6..0 6. 6....... E.. D....... F 6............
More informationAPPLICATION CONSTRUCTION
Side Channel Pumps CEH... 8 CEH /... / with magnetic coupling TECHNICAL DATA Output: Delivery head: Speed: max. m³/h max. m (at rpm) max. 8 rpm Temperature: max. 8 C Casing pressure: PN / PN Shaft sealing:
More informationPart /Assy Parts List. Production Order. Badge, Perkins/Sabre M215C. Description
Badge, Perkins/Sabre M215C Part /Assy 5242 S000000 0002 2 X X 33213 BADGE, HEADER TANK, PERKINS/SABRE M21 S000000 1 P Badge, manifold, Perkins/Sabre(34314) Part /Assy 6696 S000000 0001 1 X X 34314 BADGE,
More informationLexium integrated drives
Presentation GBX planetary gearbox Presentation In many cases the axis controller requires the use of a planetary gearbox for adjustment of speed of rotation and torque; the accuracy required by the application
More information60 Hz. e-nsc Series HORIZONTAL CENTRIFUGAL ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS
6 Hz e-nsc Series HORIZONTAL CENTRIFUGAL ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS Cod. 19112831 Rev. B Ed.7/217 Xylect TM Xylect TM is a pump solution software with an extensive online database of product
More informationGRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps
GRUNDFOS DATA BOOKLET Series circulator pumps Contents Product data MAGNA and UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids 3 Type key Performance
More informationHigh Power Contacts - Up to 850A
8 Series igh Power Contacts igh Power Contacts - Up to 850 esigned to meet the harshest military requirements where high power and shielding are needed. 3 aluminum shell sizes available Size 19 (450 max);
More informationWorking pressure. 420 bar. Style T. Style B. Style D Style V Style Z. Style S B B D.I. D.I. D.I. D.I. D.I. D.I.
5 FP SRIS FP Working pressure 40 bar Style S Style Style T Style D Style V Style Z 5 Technical data Filter body (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment)
More informationFluid Cooling Shell & Tube EC Series
Fluid ooling hell & Tube eries 01 O & TL OTTIO erformance otes ugged steel shell construction /" tube size Larger shell diameter than K,.0" maximum diameter High flow capacity & performance High efficiency
More informationFlow Divider Type MH2FA, Series 4X (Differential lock) Size 12 to 32 up to 420 bar up to 300 L/min
RE 8/0.98 8/0.9 Flow Divider Type MHF, eries X (Differential lock) ize to up to 0 bar up to 00 /min RE 8/0.98 Replaces: 0.9 Characteristics: Double-acting (dividing and summating) flow divider Fixed division
More informationSpare parts list UC-S
Spare parts list UC-S Contents Water inlet and tank heating Water softener Water drain, Mediamat Cyclo Circulating pump Wash + rinse; bottom Wash + rinse; top Boiler Dosage Panelling Cover plate, electrical
More informationGRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps
GRUNDFOS DATA BOOKLET Series circulator pumps Contents Product data MAGNA and UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids Type key 5 Performance
More informationThermal oil. Hot Water Pumps. Fields of Application
Type Series ooklet 0.50 G3 Etanorm SY Thermal Oil / Hot Water Pumps Fields of pplication Etanorm SY pumps are used in heat transfer systems (DIN 75) or in hot water circulation systems. Operating Data
More informationVacuum Pumps. Two general classes exist: Gas transfer physical removal of matter. Mechanical, diffusion, turbomolecular
Vacuum Technology Vacuum Pumps Two general classes exist: Gas transfer physical removal of matter Mechanical, diffusion, turbomolecular Adsorption entrapment of matter Cryo, sublimation, ion Mechanical
More informationVISUAL LEVEL INDICATORS
VIUL LEVEL INDICTOR LV... The level indicators series is available for both static and mobile applications; the construction materials used make it possible to guarantee service with wide temperature variations
More informationRotary Switches AC09, 16 and 32
09, 16 and 32 igital code output type escription FUJI series rotary switches offer a wide choice of output codes. They feature sliding u-flashed contacts for high contact reliability. Inhibitor and parity
More informationUniversal type Port size: M5, Rc1/8, Rc1/4. Max. working. pressure
irect acting port solenoid valve for compressed air, manifold (special purpose valve) Series Universal type Port size: M, Rc/, Rc/ Refer to nding for more details. JIS symbol ommon supply / common exhaust
More informationTHE ANSWER TO PROBLEMS OF: CORROSION, ABRASION, GRANULATED MATERIALS, POWDERS, SLUDGE, GAS ETC.
P PINC VLVE Mod. S pag. Mod. S pag. Mod. S pag. Mod. SD pag. Mod. S pag. Mod. S pag. 0 Mod. S pag. Mod. S pag. Mod. S pag. Mod. S0 pag. Mod. S pag. 0 Mod. S pag. Mod. S pag. Mod. S pag. Mod. S pag. TE
More informationPerformance. Standards. Technical data
ilos Loadbreak disconnectors for wall mounting ilos H up to 5 ilos 3 up to ilos 4 up to Order codes pplications pprovals / Marking ilos H34 ilos H ddon devices Performance Wall mounting Main disconnector,
More informationVariable Displacement Plug-In Motor A6VE. Series 6, for open and closed circuits Axial tapered piston, bent axis design
rueninghaus Hydromatik Series 6, for open and closed circuits xial tapered piston, bent axis design Size 28...20 Nom. pressure up to 400 bar Peak pressure up to 40 bar RE 9606/0.97 RE 9606/0.97 replaces
More informationABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY
ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo 22 36054 Montebello Vicentino (VI) - ITALY www.abb.com/transformercomponents The information contained in this document is for general information
More informationPilot operated 2 port solenoid valve (general purpose valve) Standard specifications NC (normally closed) type C C. 2 /s) Starting
21/22 Series (general purpose valve) 21/22 Series NC (normally closed) type, NO (normally open) type Port size: Rc1 1/4 to Rc2, 32 to 50 flange iaphragm structure JIS symbol 21: Common specifications Item
More informationSITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181
Siemens AG 09 SITRANS F flowmeters System information Overview Siemens offers two types of ultrasonic flowmeters, in-line flowmeters and clamp-on flowmeters. This offers the end user the maximum flexibility
More informationTangential Fans Series TW Impeller diameter 150 mm and 200 mm
Tangential Fans Series TW Impeller diameter mm and 0 mm 105 Corporate Drive, Suite E Spartanburg, SC 293 PO Box 2889, Spartanburg, SC 294 USA Tel: 864-599-63 Fax: 864-599-6344 e-mail: info@ltg-inc.net
More informationK DOUBLE-IMPELLER DOUBLE-IMPELLER ELECTRIC PUMPS
K DOUBLE-IMPELLER DOUBLE-IMPELLER ELECTRIC PUMPS ENERGY EFFICIENCY 7.5 TECHNICL DT Operating range: from,2 to 3 m 3 /h with head up to 97 metres. Pumped liquid: clean, free of solids and abrasives, non-viscous,
More informationELECTRONIC WET ROTOR CIRCULATORS
ELECTRONIC WET ROTOR CIRCULTORS Technical Sheet ELECTRONIC CIRCULTORS FOR ETING ND IR CONDITIONING SYSTEMS Energ ia e y GENERL DT compliant with the 3 and european directive ErP 9//EC (ex EuP) pplications
More informationKrantz Components. Twist outlet DD-N... for ceiling installation. Air distribution systems
Krantz Components Twist outlet DD-N... for ceiling installation Air distribution systems DS E 0. Twist outlet Preliminary remarks and construction design Preliminary remarks Twist outlets for ceiling installation
More informationConductivity sensor for hygienic applications
Conductivity sensor for hygienic applications Type 8221 can be combined with Perfect for demanding applications in the hygienic industry (CIP and SIP compatible) Variants available for usage over a wide
More informationELECTRONIC WET ROTOR CIRCULATORS
ELECTRONIC WET ROTOR CIRCULATORS TECNICAL DATA EVOTRON WET ROTOR ELECTRONIC CIRCULATORS Operating range: from, -, m/h with head of up to metres. Pumped liquid temperature range: from -1 C to +11 C. Working
More informationBore size: 4, 6, 8, 10. Double acting. Double acting Compressed air Withstanding pressure Ambient temperature Port size
*2 2 2 G 2 V2 /V2 V 2 * * U U G U2 2 U 2 G pecifications troke length ore size ylinder switch specifications escriptions pplications utput method ower voltage oad voltage oad current urrent consumption
More informationFlow rates to 485 l/min
FB Maximum pressure 0 bar Flow rates to 8 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Steel Check valve:
More informationHigh Pressure fi lters. FHB series. Maximum working pressure up to 32 MPa (320 bar) - Flow rate up to 485 l/min
High Pressure fi lters FHB series Maximum working pressure up to MPa (0 bar) - Flow rate up to 8 l/min High Pressure fi lters Introduction FILTER SIZING INDEX CALCULATION CORRECTIVE FACTOR Page Introduction
More information3D Drawing - CARIF 260 BSA
D Drawing - CARIF 0 BSA DRAWING CODE DRAWING NAME NUMBER ASS000 Basement ASS00 Vice Base ASS00 Vice A ASS00B Vice B ASS00 Frame A ASS00B Frame B ASS000 Frame Cylinder A ASS000B Frame Cylinder B ASS000
More informationSolenoid valve Types EVR 2 - EVR 40
Data sheet Solenoid valve s EVR 2 - EVR 40 EVR is a direct or servo operated solenoid valve for liquid, suction, and hot gas lines with HCFC and HFC refrigerants. EVR valves are supplied complete or as
More informationMetal oil filler and air breather filler caps. Bayonet connection. Reservoir holes. TA46 B (Materials)
Metal oil filler and air Series T 46 4 5 6 4 ayonet connection Ø 46 7 8 46 Reservoir holes T46 (Materials) M5 - Cover: Chrome Plated Steel - Filter element: Impregnated paper Polyurethane 64-6 - Flange:
More informationNormally Closed (N.C.), Normally Open (N.O.), Common (C.O.)
Series VVX// The models VX// have been revised. For details, please refer to catalog no. ES0-A. Similar updating Normally Closed (N.C.), Normally Open (N.O.), Common (C.O.) Courtesy of Steven Engineering,
More information