1 ELITE-CO2CABIN DIRECT ACTION Brochure and specifications INDIRECT ACTION
2 ELITE-C02CABIN (DIRECT) BENEFITS Quick anasy installation Easy maintenance Quick anasy cleaning Reduced system >> No need of large storing room Non-corrosive Suitable for ATEX environments Black, double-layering detector tube. HIGH RESISTANCE TO UV. >>In this case the tube is used as heat detector and discharge channel of extinguisher media (CO2). The temperature rise breaks the tube in the hottest point, what results in the discharge of the extinguisher media (CO2) in the seat of fire. It is Detector tube in detail Valve in detail suitable for use of total flooding of up to m3 Box content CABIN DIRECT Not affected by humidity, dirt or vibrations Efficient extinguishing Total coverage Double effect: cooling + fire containment Permanent system Independent system >> No need of electric power Total and instant detection >> Any part of the system detects the start of the fire. E l i t e x P r o t e c t i o n, S. L. C a r r e t e r a N a c i o n a l k m. 3 3, C u e n c a E S P A Ñ A Te l i n f e l i t e x. e s w w w. e l i t e x. e s ELITEX, como fabricante de extintores de incendios, garantiza todos sus productos acorde con la Ley de Garantías en la Venta de Bienes de Consumo Ley 23/2003.
3 ELITE-C02CABIN (DIRECT) PARTS LIST SPECIFICATIONS ELITE-CO 2CABIN DIRECT temperature range -20ºC/+60ºC extinguisher agent CO 2 propellant agent CO 2 minimum pressure (-20ºC) 9 bar working pressure (+20ºC) 58 bar maximum pressure (+60ºC) 74 bar testing pressure 250 bar bursting disc 90 bar nº quantity elite-co2 direct 0 m. 3 E l i t e x P r o t e c t i o n, S. L. C a r r e t e r a N a c i o n a l k m. 3 3, C u e n c a E S P A Ñ A Te l i n f e l i t e x. e s w w w. e l i t e x. e s description cylinder CO2 (light steel) direct action valve cylinder bracket sensor tube end of line and pressure gauge
4 ELITE-C02CABIN (INDIRECT) VENTAJAS Quick anasy installation Easy maintenance, no need of shutdown Quick anasy cleaning Reduced system >> No need of large storing room Non-corrosive Suitable for ATEX environments Black, double-layering detector tube. HIGH RESISTANCE TO UV >>The sensor tube detects the fire and activates the differential pressure valve of the extinguisher media cylinder (CO2), allowing the discharge of the media through the discharge tube until the diffuser. This system allows manual shot activation. Waste free Switch detail Not affected by humidity, dirt or vibrations Box content CABIN INDIRECT Efficient extinguishing Total coverage Double effect: cooling + fire containment Permanent system Independent system >> No need of electric power Total and instant detection >> Any part of the system detects the start of the fire. It allows communication with alarm generated by a trip Optional Communication valve opening/closea E l i t e x P r o t e c t i o n, S. L. C a r r e t e r a N a c i o n a l k m. 3 3, C u e n c a E S P A Ñ A Te l i n f e l i t e x. e s w w w. e l i t e x. e s ELITEX, como fabricante de extintores de incendios, garantiza todos sus productos acorde con la Ley de Garantías en la Venta de Bienes de Consumo Ley 23/2003.
5 ELITE-C02CABIN (INDIRECT) PARTS LIST SPECIFICATIONS ELITE-CO 2CABIN INDIRECT temperature range -20ºC/+60ºC extinguisher agent CO 2 propellant agent CO 2 minimum pressure (-20ºC) 9 bar working pressure (+20ºC) 58 bar maximum pressure (+60ºC) 74 bar testing pressure 250 bar bursting disc 90 bar 2 nº quantity elite-co2 indirect 0 m. 8 E l i t e x P r o t e c t i o n, S. L. C a r r e t e r a N a c i o n a l k m. 3 3, C u e n c a E S P A Ñ A Te l i n f e l i t e x. e s w w w. e l i t e x. e s description cylinder CO2 HP light steel indirect action valve flexible connecting tube pipe cylinder bracket sensor tube nickel nozzle 3 exits emergency button (optional) end of line and pressure gauge
6 ELITE-C02CABIN SENSOR TUBE Black sensor tube (4x6) made of polyamide especial & modified. Tube extruded, with two layers, UV levelled. The tube useful life is of 8-0 years in normal environmental situations. Refer to manufacturer in case of use in different situations. Through the pressure reducer the valve sets the pressure of the sensor tube Detalle tubo sensor at 8 BAR at 20º C aprox. TABLE OF DETECTION TEMPERATURE RANGE OF THE TUBE BASED ON ITS PRESSURE USES 250 >Electrical panels 200 >Machinery >Equipment and laboratory extraction hoods 50 >Technological machinery >Vehicles >Truck storage >IT servers >Battery compartment >ATM 0 5 F00 red 4x6 20 F02 black 4x6 (multilayering) >Military vehicles >Battery chargers >Paint cabins >Generators >Flammable cabinet >Wind plants F02 black 5,3x8 (multilayering) E l i t e x P r o t e c t i o n, S. L. C a r r e t e r a N a c i o n a l k m. 3 3, C u e n c a E S P A Ñ A Te l i n f e l i t e x. e s w w w. e l i t e x. e s ELITEX, como fabricante de extintores de incendios, garantiza todos sus productos acorde con la Ley de Garantías en la Venta de Bienes de Consumo Ley 23/2003. temperature explosion [ºC]
7 Elitex Protection, S.L. Carretera Nacional 320 km. 33, Cuenca ESPAÑA Te l i n f e l i t e x. e s
8
ebro has expanded its range of measuring instruments in the food area even further: ebro Data Logger Family EBI 20
ebro has expanded its range of measuring instruments in the food area even further: ebro Data Logger Family EBI 20 For comprehensive documentation and monitoring of temperature, pressure and humidity in
More informationSTATE OF COLORADO DESIGN CRITERIA FOR POTABLE WATER SYSTEMS WATER QUALITY CONTROL DIVISION. Price: $5.00. Revised March 31, 1997
STATE OF COLORADO DESIGN CRITERIA FOR POTABLE WATER SYSTEMS WATER QUALITY CONTROL DIVISION Revised March 31, 1997 Price: $5.00 a. an arrangement where the water pipe to be injected with chlorine enters
More informationH i g h A m p e r a g e 2 5 t o A M P. T y p e I & I I I V e h i c l e P r o t e c t i o n. I P 6 7 W a t e r p r o o f
H i g h A m p e r a g e 2 5 t o 3 0 0 A M P T y p e I & I I I V e h i c l e P r o t e c t i o n I P 6 7 W a t e r p r o o f I g n i t i o n - P r o t e c t e d S A E & A B Y C C o m p l i a n t L E D T
More informationCooling Water Flow Regulator
Temperature controlled, indirectly and directly actuated diaphragm valves / seat valves Port size G 3/8 to G DN 0 to DN 0 ontinuous regulation High accuracy No auxiliary energy required Technical data
More informationLABOTRON EXTRACTION & SYNTHESIS 2450 MHz
LABOTRON EXTRACTION & SYNTHESIS 2450 MHz The LABOTRON TM series is the generic name for a ground breaking range of integrated reactor and microwave transmission systems especially designed to carry out
More informationPressure transmitters for industrial applications MBS 32 and MBS 33
Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer
More informationMAINTENANCE EVALUATION CHECKLIST HYDRAULIC ELEVATORS
Manufacturer: Model: Evaluation Performed By: INTRODUCTION: This checklist will enable the user to make an objective appraisal of the condition of the equipment. Given the variety and complexity of the
More informationPFI Closed circuit cooling towers
PFI Closed circuit cooling towers Key benefits Lowest energy consumption and total cost of ownership Year round reliable operation Ideal replacement unit with certified thermal performance PFI characteristics
More informationKey points. Discuss why contact lenses are not allowed in the chemical laboratory. Short pants Skirt Scandals Open-toed shoes
(a) Personal protective equipment When you are working in a chemical laboratory, explain the purposes of wearing different types of personal protective equipment Discuss why contact lenses are not allowed
More informationED 701 General Industry Pressure Transmitter
ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationTransmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level
Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level
More informationDMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm
DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up
More informationDMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output
More informationStructure Monitoring Technology. Features. Ordering Information. Trigger Tape. A2 Pulse Counter (Optional) Solar Radiation Sensor
Rain detection sensor General Description Driving rain and its effective management are critical factors in determining the durability of building enclosures. An accurate measurement of driving rain can
More information2.9. Namur Valves 2.9. page 175. Namur 1/4 also called Namur 1 in accordance to VDI / VDE Namur 1/2 also called Namur 2.
2.9 page 175 Namur 1/4 also called Namur 1 in accordance to VDI / VDE 3845. Namur 1/2 also called Namur 2. 2.9 Namur Valves + Selected models are available for low temperature application. Temperature-range:
More informationMetso Concentration Measurement 3300
Metso Concentration Measurement 3300 Metso Concentration 3300 Accurate direct in-line measurement The Concentration Measurement is provided with intelligent technology calculating the concentration of
More informationSITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181
Siemens AG 09 SITRANS F flowmeters System information Overview Siemens offers two types of ultrasonic flowmeters, in-line flowmeters and clamp-on flowmeters. This offers the end user the maximum flexibility
More informationDS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.
DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link
More informationALC. ALBATROSS Supply air terminal for large airflows
ALBATROSS Supply air terminal for large airflows Quick facts Large airflows Suitable for cooling or heating Manual or motorised adjustment Pressure drop independent of selected spread pattern Can be used
More informationSurface-mounting Thermostats ATH Type Series
Page 1/9 urface-mounting Thermostats ATH eries k enclosure protection IP 54 k tested to IN EN 14597 (replacing IN 3440) Brief description Thermostats control and monitor thermal processes. Instruments
More informationPressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27
Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for
More informationWeatherHub2 Quick Start Guide
WeatherHub2 Quick Start Guide Table of Contents 1 Introduction... 1 2 Packing List... 1 3 Connections... 1 4 IP Addressing... 2 5 Browser Access... 3 6 System Info... 3 7 Weather Station Settings... 4
More informationPressure Measurement Single-range transmitters for general applications
Siemens AG 07 Overview Function SITRANS LH00 Transmitter for hydrostatic level U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/
More informationWS-9018U Wireless Weather Station. Instruction Manual
WS-9018U Wireless Weather Station Instruction Manual Contents Page 1. Functions of the Weather Station....3 2. Safety notes...3 3. Product features....4 4. Getting started....4 5. Quick Set Up...5 6. Setting
More informationOperating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014
Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM8004 80003223 / 00 05 / 2014 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...4 3 Functions and features...5
More informationIR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer
INSTRUCTION MANUAL Thermometer DUAL-LASER TARGETING 12:1 DISTANCE- TO-SPOT RATIO AUTO-SCAN MAX/MIN/AVG/DIFF HIGH/LOW ALARM BACKLIT DISPLAY AUTO POWER-OFF ADJUSTABLE EMISSIVITY IR5 2m -22 752 F (-30 400
More informationDewpoint Meter Data Sheet / Instructions
Paint Test Equipment Dewpoint Meter Data Sheet / Instructions Dewpoint Meter Information ISO 8502-4: Preparation of steel substrates before application of paints and related products. Tests for the assessment
More informationFacts and figures MULTILIFT SELECT 15
Facts and figures MULTILIFT SELECT 15 www.arburg.com MULTILIFT SELECT 15 Technical data min. 180 Stroke Z-axis Stroke X-axis Clamping face fixed mould platen 220 E A D K Stroke Y axis 195 B 2) C 157 P
More informationVDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems
06 EN - Straight valves VDN.. Angle valves VEN.. Reverse angle valves VUN.. ACVATIX TM Radiator valves NF norm, for -pipe heating systems VDN.. VEN.. VUN.. Valve bodies made of brass, mat nickel-plated
More informationSerie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18
erie B. Flanged ductile iron ball valve BRanDOni made in E U R O P E Application fields WATER CONdITIONING GA EATING INdUTRY FIRE FIGTING www.brandoni.it erie B. eries B. valves are shut-off ball valves
More informationData Sheet / Instructions. Dewpoint MeterO
Data Sheet / Instructions Dewpoint MeterO Dewpoint Meter ISO 8502-4: Preparation of steel substrates before application of paints and related products. Tests for the assessment of surface cleanliness.
More informationNCFP. Nickel Cadmium Fibre Plate Batteries. Dimensional and Electrical Data
NCFP Nickel Cadmium Fibre Plate Batteries Dimensional and Electrical Data Nickel Cadmium Fibre Electrode Batteries Nickel Cadmium Fibre electrode batteries may be seen as 3rd generation (1 s) technology.
More informationINFRARED THERMOMETER TM0819
INFRARED THERMOMETER Instruction Manual HORMES LIMITED cs@perfectprime.com G/F UNIT 3, 61 GLENTHORNE ROAD, LONDON W6 0LJ UNITED KINGDOM +44 203 7695377 Retailer Email Address Telephone P.1 CONTENTS 1.
More informationPG-100 HANDY MANOMETER COPAL ELECTRONICS FEATURES MODEL NUMBER DESIGNATION P G G P. marking Compatible with EMC directive
HANDY MANOMETER Power button Hold button marking Compatible with EMC directive Digital 3 1/2 digits Zero adjustment VR FEATURES Excellent stability State of the art sensor and circuit technology guarantees
More informationSELF-AUDIT CHECKLIST
SELF-AUDIT CHECKLIST Service Department Location: Date: Conducted By: Dept: GENERAL 1. Is proper footwear worn in the Service Department? ( ) ( ) ( ) ( ) 2. Are smoking rules posted where there is a serious
More informationDM70 Hand-Held Dewpoint Meter for Spot-Checking Applications
DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed
More informationIndividual Laboratory Safety & Chemical Hygiene Plan
APPENDIX A: CHEMICAL HYGIENE PLAN Part B Individual Laboratory Safety & Chemical Hygiene Plan Principal Investigator Date filed Department Building/Floor/Room E-mail address @Pace.edu Phone Facsimile Laboratory
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationBERMAD Irrigation. BIC2000 Weather Station SYSTEM GUIDE VERSIONS : BIC ; PC 4.90
BIC2000 Weather Station SYSTEM GUIDE VERSIONS : BIC2000 3.92; PC 4.90 CONTENTS 1. SYSTEM OVERVIEW 3 2. WEATHER STATION SETUP 4 2.1 ISS AND CONSOLE SETUP 4 2. RF RTU SYSTEM SETUP 5 2.2 BIC2000 WEATHER STATION
More informationFlammable/Combustible Liquid Storage
8.12.1 RESPONSIBILITY University personnel are responsible for using approved and safe methods for storing flammable/combustible liquids. Personnel must store flammable and combustible liquids in accordance
More informationOPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820
Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820 Your purchase of this PEN VIBRATION METER marks a step forward for you into the field of precision measurement.
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationWater terminal control solutions
Water Terminal Control Solutions Water terminal control solutions Carrier offers a wide range of fan coil units designed to meet the needs of different systems and applications: from cabinet units in the
More informationNCFP. Nickel Cadmium Fibre Plate Batteries. Dimensional and Electrical Data
NCFP Nickel Cadmium Fibre Plate Batteries Dimensional and Electrical Data Nickel Cadmium Fibre Electrode Batteries Nickel Cadmium Fibre electrode batteries may be seen as 3rd generation (1 s) technology.
More informationVD1 CLC. Small Valves DIN-range with a higher k v -value
0 EN - Small Valves DIN-range with a higher k v -value VD CLC Valve body made of brass, mat nickel-plated DN, DN 0 and DN Internally and externally threaded (Rp / R) conforming to ISO 7- Manual knob /
More informationCoating Thickness Gauge TW-8. art. nr Thoma Tel./Fax: Operation Manual
Coating Thickness Gauge art. nr. 59252 Table of contents 1. Technical specifications...3 2. Getting started...3 3. Gauge manual...6 The price of this product includes the recycling fee of 0,10 PLN Guarantee...11
More informationCoflore Agitated Cell Reactor
Coflore Agitated Cell Reactor Coflore ACR The Coflore ACR is a lab flow reactor developed by AM Technology for studying chemistry in flow and developing scalable continuous processes. Its flexible design
More informationRIMA OFFICIAL CATALOGUE CATALOGUE TP
RAIL BRAKES RIMA OFFICIAL CATALOGUE UE 1 / 1 4 FEBRUARY 2013 CATALOGUE TP UE 2 / 1 4 DescriPt Ption Utilization and functioning Rail brakes, suitable for medium forces from 20 to 300 kn (securing cranes
More informationState Unitary Enterprise Production Amalgamation Novosibirsk Instrument-Making Plant PN-6K. Servise Manual
State Unitary Enterprise Production Amalgamation Novosibirsk Instrument-Making Plant Night Sight PN-6K Servise Manual Contents 1. General directions 4 2. Specifications 5 3. Delivery set 6 4. Safety regulations
More informationPressure Transmitter ED 701
Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation
More informationCALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05
Modulating digital controller for heating and cooling series REGI ERED SI EN ISO 00:000 Cert. n FM UNI EN ISO 00:000 Cert. n 000 0/0 G replaces dp 0/0 Function The controller can be used with three-point
More informationOPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820
Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820 Your purchase of this PEN VIBRATION METER marks a step forward for you into the field of precision measurement.
More informationseries KAT Acoustic air transfer units
series Acoustic air transfer units www.koolair.com 1 Acoustic Air Transfer Unit CONTENTS Acoustic Air Transfer Unit 2 Dimensions 3 Technical Data 5 Product Codes 7 2 Acoustic Air Transfer Unit - Description
More informationDigital Controller Operation
A Family Company Manufacturing In The USA Since 1969 Full Gauge Digital Controller Operation This manual is specific to the operation and diagnostic guides of the Full Gauge digital controller used in
More informationv = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes
Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes Examples of Application Flow measurements also in hazardous locations X zone 0 or zone 1 in clean rooms in air
More informationResidual Chlorine Monitor
Data Sheet SS/AW00 Issue Residual Chlorine Monitor AW00 Total and Free Residual Chlorine Measurement add potassium iodide to reagent to convert free chlorine measurement to total chlorine Reagentless Operation
More informationAIR COOLED CONDENSING UNIT
EVOLUTION SERIES AIR COOLED CONDENSING UNIT OUTDOOR AIR COOLED CONDENSING UNIT ORIGINAL MANUFACTURED EQUIPMENT Evolution Series BA-503-3 AUS Evolution Air Cooled Condensing Unit Series Content Page Explanation
More informationHow to Check Your G4 Spread Pattern
How to Check Your G4 Spread Pattern MANUAL NUMBER: EFFECTIVE 04/0 0 6TH AVE SW CEDAR RAPIDS, IA 5404-05 PHONE FAX (9) 86-50 www.new-leader.com Copyright 0 Highway Equipment Company, Inc. Spread HeaderPattern
More informationKjeltec 2300 Analyzer Unit
Kjeltec 2300 Analyzer Unit Automatic distillation and approved colorimetric titration for analysis of Kjeldahl nitrogen/protein, ammonium- nitrogen, TKN, Direct distillation (DD), volatile acids/ bases
More informationChemical Health and Safety General Program
Chemical Health and Safety General Program I. Objective To establish minimum requirements for storage, handling and use of chemicals. II. Scope This process applies to employees and operations involved
More informationNozzle diffuser. Dimensions
Dimensions ØU Ød H 0 ØA Description is a circular diffuser with individually adjustable nozzles. The diffuser is suitable for the horizontal supply of cooled air, where great flexibility in the dispersal
More informationThe electronic actuator for future-proof applications
Stellantriebe The electronic actuator for future-proof applications Safe Economical Precise www.arisactuators.com Intelligent Line The next generation actuator technology Innovative electronics versus
More informationTRAM LINE SWITCH POINT HEATING
ENERGY SAVING SMART WEATHER CONTROL TRAM LINE SWITCH POINT HEATING 50 80% Energy saving Heating controlled by weather conditions and weather forecast Long life heating elements Shield material is Monel
More informationIntroduction. Energy Generation with the Piezo Effect
Introduction The term Energy Harvesting is popularly used when electricity is generated from sources such as ambient temperature, vibrations or air flows. Since there are now electronic circuits whose
More informationIL series. Centrifugal marine IN-LINE pumps
IL series Centrifugal marine IN-LINE pumps DESCRIPTION Vertically built centrifugal IN-LINE pumps are made with standardized DIN-22 parts, with in-line suction and discharge flanges. This arrangement requires
More informationLow Differential Pressure Gage
Low Differential Pressure Gage NEW Manostar Gage Panel installation compact type Low Differential Pressure Gage RoHS compliant Utility model registration No.2027772 Compact and lightweight type Even when
More informationSENSOR. Weather TRANSMITTERS
Weather SENSOR TRANSMITTERS 4~20mA Environmental Monitoring Probe Sets Anemometer (Wind Speed) Wind Vane Light Energy Sensor (Pyranometer) Solar Radiation Shield Model THP-CL Humidity Sensor Temperature
More informationCoriolisMaster FCB430, FCB450, FCH430, FCH450 Coriolis mass flowmeter
Data Sheet DS/FCB400/FCH400-EN Rev. D CoriolisMaster FCB430, FCB450, FCH430, FCH450 Coriolis mass flowmeter High precision measurement of mass and volume flow, density, temperature and concentration with
More informationSafety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.
Safety Precautions Observe the following notices to ensure personal safety or to prevent accidents. To ensure that you use this product correctly, read this User s Manual thoroughly before use. Make sure
More informationJDV CONTROL VALVES CO., LTD. JCT/JCTM Series 3/4 Way Trunnion Type Valve Manual
JCT/JCTM Series 3/4 Way Trunnion Type Valve Manual 1. Please read this manual before installation or servicing. 2. Before installing or servicing, please ensure the line pressure has been relieved and
More informationSafety in the Chemistry Laboratory
Safety in the Chemistry Laboratory CHAPTER1 Safety must be everyone s primary concern in the chemistry lab. Understanding and following all safety rules in the organic chemistry lab is critical to your
More informationNo HOT WIRE ANEMOMETER MODEL SK-27V. SPECIFICATIONS Measurement object : Clean air at normal pressure and humidity
ELECTRIC INSTRUMENTS HOT WIRE ANEMOMETERS No. 7693-00 HOT WIRE ANEMOMETER MODEL SK-73D Measurement object: Clean air at normal pressure and humidity Measuring range Air velocity : 0 to 30 m/s Air temperature:
More informationOSH in Medical Laboratory
OSH in Medical Laboratory Mr. K K LEUNG M(OSH) HRD HAHO Induction Program for Newly Recruited AMT 28 March 2008 Contents 1. Ordinance and Regulations 2. HA Safety Manuals 3. Chemical Safety 4. Biological
More informationPOWER PUSHER Snowplow
May 15, 2013 Lit. No. 43682, Rev. 00 POWER PUSHER Snowplow 8' 72040; 10' 72045; Box Plow for Skid-Steer Loaders Owner's Manual and Installation Instructions Original Instructions CAUTION Read this manual
More informationKalinka Optics Warehouse User Manual Kobra AK Side Mount Red Dot Sight Manual
Kalinka Optics Warehouse User Manual www.kalinkaoptics.com Kobra AK Side Mount Red Dot Sight Manual CONTENTS 1. Introduction... 4 2. Purpose... 4 3. Specifications... 4 4. Components and Equipment Provided...
More informationPG-200/PG-208 PRESSURE GAUGES P G G P P
Digital 3 1/2 digits monitor Set button for switch output HI or LO (PG-200) (PG-208) Digital 3 1/2 digits Power switch LO setting VR for switch output LO HI setting VR for switch output HI SPAN adjustment
More informationFVBSS fixed volume bottle
N FVBSS fixed volume bottle Sampling System The SENSOR Fixed Volume Bottle Sampling System (FVBSS) provides a repeatable fixed volume of sample during each sampling process without stopping flow of the
More informationChemical Storage Guide
1 P a g e Chemical Storage Guide It is the responsibility of every occupant, owner, tenant, contractor, employee & visitor and ALL users of this facility to ensure they take all reasonably practical steps
More informationVIBRATION METER Acceleration & Velocity Model : VB-8201HA
VIBRATION METER Acceleration & Velocity Model : VB-8201HA TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS...2 3. FRONT PANEL DESCRIPTION...4 3-1 Display...4 3-2 BNC socket of meter...4 3-3 RMS/PEAK
More informationInfrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL
Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL TABLE OF CONTENTS TITLE PAGE INTRODUCTION...1. SAFETY INFORMATION...2. FEATURES...4. SPECIFICATIONS...4.
More informationPAA-ANALYZERS PRINCIPLE OF OPERATION
PAA-ANALYZERS PRINCIPLE OF OPERATION The PAA process analyzer comprises a control unit and an analyzing section which includes the reaction chamber and measuring cell, reagent pumps and associated valves
More informationCFC, HCFC free, GWP zero thermal insulation in the form of tubes, sheets, coils and self-adhesive tape, a Flexible Elastomeric Foam product complying
CFC, HCFC free, GWP zero thermal insulation in the form of tubes, sheets, coils and selfadhesive tape, a Flexible Elastomeric Foam product complying with the European standard EN. EUROBATEX is a closed
More informationHudevad P100. Technical datasheet
Technical datasheet Key benefits Available in three depths Highly flexible in use Integrated top grille Harmonious and finished look Kundenedfal Low, streamlined design Ideal in front of glazing to prevent
More information4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)
.2 Ex-Ceiling light fittings AB 8 / AB 5 LED / AB 5 / AB 12 NAV 7 (Zone 1, 2, 21, 22) The wall and ceiling light fixtures for particularly difficult operating conditions The impact-resistant and flameproof
More informationNew! 2010 Model. Model No
Model No. 15945 New! 2010 Model Features: Model #15945 is an advanced lightweight ultrasonic thickness gage that is designed to be convenient to use and rugged enough to operate in harsh environments.
More informationCFC, HCFC free, GWP zero thermal insulation in the form of tubes, sheets, coils and self-adhesive tape, a Flexible Elastomeric Foam product complying
CFC, HCFC free, GWP zero thermal insulation in the form of tubes, sheets, coils and selfadhesive tape, a Flexible Elastomeric Foam product complying with the European standard EN. EUROBATEX is a closed
More informationDeionized Water. Latest technology, highest quality, environmentally friendly. Water Technologies
Deionized Water Latest technology, highest quality, environmentally friendly Water Technologies NaCl OH - Cl - OH - OH - Cl - Anion OH - OH - Resin OH - OH OH - - OH - OH - Na + Na + Cation Resin H + H
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. PGC5000 Temperature programmed gas chromatograph
ABB MEASUREMENT & ANALYTICS DATA SHEET PGC5000 Temperature programmed gas chromatograph 2 P G C 5 0 0 0 T E M P E R AT U R E P R O G R A M M E D D S/ P G C 5 0 0 0 T P - E N Measurement & Analytics The
More informationMagnetic Separators for Recycling
Magnetic Separators for Recycling Driven by magnetism since 1959 In recent years, Goudsmit Magnetics has significantly extended its set of magnetic systems for the recycling industry. This brochure gives
More informationExplosion-protected recessed ceiling LED-light and fluorescent light fittings
.7 Explosion-protected recessed ceiling LED-light and fluorescent light fittings LED 600, RLF LED 100 and self-contained emergency luminaire RLF LED 600 N, RLF LED 100 N RLF/RLF-INOX 50 18-58 W / RLF/RLF-INOX
More informationITS Sensors. Intelligent Transportation System. The future of mobility and trafic management
ITS Sensors Intelligent Transportation System The future of mobility and trafic management Pavement Sensors Rugged design Monitors pavement condition RS485 output with open protocol Low power consumption
More information50 Gordon Drive, Rockland, Maine sherplows.com. STORM BOXX Snowplow. 10' and 12' Box Plow for Backhoe Loaders
Fisher Engineering 50 Gordon Drive, Rockland, Maine 04841-2139 www.fi sherplows.com 83180, 83185 May 15, 2013 Lit. No. 43687, Rev. 00 STORM BOXX Snowplow 10' and 12' Box Plow for Backhoe Loaders Owner's
More informationIBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationEX-EMERGENCY LIGHT FITTINGS
EX-EMERGENCY LIGHT FITTINGS nllk 0...N 1-36 W Plastic version for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 N are conform to the requirements of the ATEX-Directive
More informationIBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More information5SJ4...-.HG Circuit Breakers to IEC and UL 489
Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is
More informationInfrared Thermometer Model: and
Infrared Thermometer Model: 72-820 and 72-823 1 IMPORTANT SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. Please operate according to this manual,
More informationExercise 4-3. Titration of Weak Acids EXERCISE OBJECTIVE DISCUSSION OUTLINE. The 5% rule DISCUSSION
Exercise 4-3 Titration of Weak Acids EXERCISE OBJECTIVE Titrate both a weak acid solution and a weak polyprotic acid solution with a strong base solution. Plot a graph using the titration data, analyze
More informationEOSMS Guidelines Date: 01/16/2014 Page 1 of 5
EOSMS Guidelines Date: 01/16/2014 Page 1 of 5 Introduction The Department of Environmental Health, Safety has developed generic standard operating procedures relevant to safety and health considerations
More informationDifferential ph Probe Type 18
Differential ph Probe Type 18 Contents 1 Introduction 1.1 Glass testing 2 Measuring principle 2.1 Model applications 3 Technical data 4 Handling information for the glasslined ph probe 5 Storage and installation
More information