Mark 55, SPA55 & PA55 Series

Size: px
Start display at page:

Download "Mark 55, SPA55 & PA55 Series"

Transcription

1 single solenoid open center single solenoid pilot closed center pilot 5 orted, 2 and 3 position, 4-way, Spool & Sleeve v: 5.5 Direct solenoid, solenoid pilot, or air pilot actuated lug-in solenoid with indicator light (ark 55 and S 55) nlubricated or lubricated service Integral speed control available Integral regulators available N 4 / I65 pilot open center pilot closed center single air pilot with spring offset 3 osition 4-Way (5/3), open to 4 and 2 in center double air pilot 3 osition 4-Way (5/3), open to 4 and 2 in center open center closed center pilot 3 osition 4-Way (5/3), open to 4 and 2 in center

2 echnical Data VV D NGISH ark 55 Only RI v 3/8 N = 4.0 1/2 N = 5.0 3/4 N = 5.5 G3/8 = 5.0 G1/2 = 5.0 G3/4 = 5.5 low capacity 185 S 232 S 255 S pstream pressure to SIG 3940 NI/m 4925 NI/m bar upstream/5 bar downstream Operating ressure Range 28 Hg. Vacuum to 150 SIG ilot ressure Range 2-osition, Single, 2-osition, Double, 3-osition, 20 to 5 SIG 15 to 5 SIG 20 to 5 SIG emperature Range (ambient) ark 55 S to to to to +46 Operating Data - ark 55 SONOIDS R ONINOS DY RD 24 V 115 V 0 V 230 V 240 V ower (Watts) Single Solenoid Double Solenoid N/ N/ Holding urrent (mps.) Single Solenoid Double Solenoid Inrush urrent (mps.) Single Solenoid Double Solenoid nergize in seconds De-energize in seconds 2-osition, Single, 2-osition, Double, 3-osition, 2-osition, Single, 2-osition, Double, 3-osition, N/ N/ N/ N/ N/ Operating Data - S 55 SONOIDS R ONINOS DY RD 24 VD 24 V 24 V 115 V 0 V 230 V 240 V ower (Watts) 4.0 N/ N/ N/ N/ N/ N/ 4 nergize in seconds De-energize in seconds Holding urrent (mps.) Inrush urrent (mps.) 2-osition, Single, 2-osition, Double, 3-osition, 2-osition, Single, 2-osition, Double, 3-osition, N/ N/ N/ N/ N/ N/ N/ N/

3 How to Order Valves 553 S 4 15 K Valve Series & ort Size 553 = 3/8 554* = 1/2 555 = 3/4 *Valve unit only. Valve ype S = Single Direct Solenoid, w/lush Non-ocking Override (Std.) SS = Double Direct Solenoid w/lush Non-ocking Override (Standard) = Single Solenoid ilot, w/lush Non-ocking Override = Double Solenoid ilot w/lush Non-ocking Override J = Single ir ilot, JJ = Double ir ilot JK = Double ir ilot, w/lush Non-ocking Override (2 position Only) = Single ir ilot, w/out Override = Double ir ilot w/out Override unction 4 = 2 osition, 4-Way 5 = 3 osition, 4-Way Open enter 6 = 3 osition, 4-Way losed enter 7 = 3 osition 4-Way (5/3), Open to 4 and 2 in enter ounting 00 =Valve nit Only 01 =Valve nit Only w/speed ontrol 2 = 15 w/ompact anifold lock 2 = 2 w/speed ontrol 2 = 2 w/uxiliary Inlet 2 = 2 w/lternate Outlet 2G = 2 w/lternate Outlet & uxiliary Inlet 3 = Individual ase, Side orts, Individual xhaust 3 = Individual ase, Side and ottom orts, Individual xhaust 3 = 3 w/speed ontrol 3D = 3 w/speed ontrol 15 = anifold lock w/side and ottom ylinder orts 25 = 15 w/speed ontrol 31 = lug-in ase, Side orts, ommon xhaust 32 = Individual ase, Side and ottom orts, ommon xhaust 35 = 31 w/speed ontrol 36 = 32 w/speed ontrol Voltage 00 = ir ilot 20 = 24/50-60 V 30 = 110-0/50-60 V 40 = /50-60 V 61 = 24 VD (S only) Options 11 = lush ocking Override 11Z = xtended ocking Override (ark 55 & 55) 13 = 48" eads (ark 55 & S 55) = Internal ilot Supply from if Not Standard (S 55 only) = Internal ilot Supply from (3) (S 55 only) D = Internal ilot Supply from (5) (S 55 only) X = xternal ilot Supply hrough anifold (S 55 only) 16 = ottom orts 19 = erminal lock in onduit rea (ark 55 & S 55 only) 46 = Zinc lated rmature (ark 55 only) ort ype 0 = N G = G ap = G ap (Solenoid ilot Valves) = N (Solenoid ilot Valves) Wiring Option J = lug-in w/ight and Speed ontrol (se only with 01 mounting) K = lug-in w/ight = lug-in D w/ight (S 55 only) O = Not pplicable (sed for ir ilot) Q = lug-in D w/ight and Speed ontrol (se only with 01 mounting) 6 = DIN lug-in w/ight (ark 55 only) NO: or S Series valves, internal pilot supply is standard as follows: 4 = internal from port 4 = internal from port 5 = internal from port 6 = internal from port 5

4 ark 55 Valve on Individual ase 1/2 N conduit port connection D G H I J K R S D O O Q 3/4 N ommon xhaust (only) 3/8, 1/2, 3/4 N or G (5) V Optional ottom ort ocations (5) 3/8, 1/2, or 3/4 N or G tap W W X X Dimensions top dimensions = inches and bottom dimensions (in parenthesis) = millimeters D G H I J K O 1.19 (30.2) 0.94 (23.9) 0.28 (17.1) 1.38 (35.1) 2.76 (70.1) 5.88 (9.4) 5.49 (139.4) 8.49 (215.6) (276.1) 2.56 (65.0) Q R S V W X 3.38 (85.9) 2.06 (52.3) 3.10 (78.7) 4.26 (108.2) 1.59 (40.4) 7.30 (185.4) 0.88 (22.4) 8

5 55 Valve on Individual ase D.28 (7.1) Diameter 2 ounting Holes 1/8 N or G ap ilot ort J I 1/8 N or G ap ilot ort R H K Q G 3/4 N or G ap ommon xhaust (only) N O 3/8, 1/2, or 3/4 N or G ap 5 orts S 3/8, 1/2, or 3/4 N or G ap ottom orts Optional V V Dimensions top dimensions = inches and bottom dimensions (in parenthesis) = millimeters D G H I J K 5.88 (9.4) 1.38 (35.1) 2.76 (70.1) 0.37 (9.4) 1. (28.4) 0.25 (6.4) 8.07 (205.0) 4.03 (102.4) 1.19 (30.2) N O Q R S V 1.59 (40.4) 3.00 (76.2) 7.28 (184.9) 2.06 (52.3) 3.10 (78.7) 4.26 (108.2) 1.00 (25.4) 1.69 (42.9) 3.39 (86.1) 0.88 (22.4) 9

6 S 55 Valve on Individual ase D J I H K N O G R Q S 3/8, 1/2, or 3/4 N ottom orts Optional Dimensions top dimensions = inches and bottom dimensions (in parenthesis) = millimeters D G H I J K 5.88 (9.4) 1.38 (35.1) 2.76 (70.1) 0.37 (9.4) 1. (28.4) 0.25 (6.4) (263.4) 5.18 (131.6) 1.19 (30.2) 1.59 (40.4) N O Q R S 7.28 (184.9) 2.06 (52.3) 3.10 (78.7) 4.26 (108.2) 1.00 (25.4) 1.69 (42.9) 3.38 (85.8) 0.88 (22.4) 10

LO1 SERIES. compact direct solenoid actuated valves

LO1 SERIES. compact direct solenoid actuated valves SRS compact direct solenoid actuated valves 0 d i r e c t s o l e n o i d a c t u a t e d v a l v e s T N T................................................... V V O S T O N........................................

More information

MICRO-AIR SERIES. miniature direct solenoid actuated valves

MICRO-AIR SERIES. miniature direct solenoid actuated valves R-R SERES miniature direct solenoid actuated valves RR i c r o i r d i r e c t s o l e n o i d a c t u a t e d m i n i a t u r e v a l v e s T E D T................................................... 3

More information

Valve Products ADEX Series Valves

Valve Products ADEX Series Valves atalog 000-2US X alves X is a miniature low power consumption solenoid valves, ideal for powering small to mid-sized pneumatic actuators used in automation and process applications. X's versatility is

More information

5/2-5/3 SPOOL VALVES MULTIFUNCTION air operated or solenoid air operated with subbase ISO 5599/1 sizes 1, 2 and 3

5/2-5/3 SPOOL VALVES MULTIFUNCTION air operated or solenoid air operated with subbase ISO 5599/1 sizes 1, 2 and 3 / - / SPOOL VALVES MULTIFUNCTION air operated or solenoid air operated with subbase ISO 99/ sizes, and Series Fluids air or inert gas, filtered, lubricated or not Operating pressure Pilot pressure Ambient

More information

Basic Features PAR -15 Series Features PAR TM -15 (Patent No. 4,630,632) is a unique 3-Way, programmable, air regulating valve that functions as a pre

Basic Features PAR -15 Series Features PAR TM -15 (Patent No. 4,630,632) is a unique 3-Way, programmable, air regulating valve that functions as a pre PAR -15 Series Basic Features...2 Model Number Index...3 Solenoid Operated Valves...4 Truth Table & Dimensions...5 Narrow Band ontrol and ascading...6 ascading Truth Table...7 Technical Information...

More information

PAR-15 Series. PAR -15 Series Valves

PAR-15 Series. PAR -15 Series Valves PAR-15 Series Proportional Regulators PAR -15 Series Basic Features... 32 Model Number Index... 33 Solenoid Operated Valves... 34 Truth Table & Dimensions... 35 Narrow Band ontrol and ascading... 36 ascading

More information

Discontinued BL Series, Cross-Reference to MicroKing Series

Discontinued BL Series, Cross-Reference to MicroKing Series 4908 Discontinued BL Series, Cross-Reference to ISSUED: April, 2000 Discontinued BL Series, Cross-Reference to BL Series BL Valve will be discontinued December, 2000 General Notes: Parker BL Valve is the

More information

A wide selection of pipe and orifice sizes is offered. Valves are available with threaded ports in brass and stainless steel.

A wide selection of pipe and orifice sizes is offered. Valves are available with threaded ports in brass and stainless steel. Solenoid Valve Waterhammer-Free, 0- PSI /-Way; NPT - NPT; 0- PSI Advantages/Benefits Type 63 Waterhammer-free Low noise Zero differential pressure ompact design with high flow rates Low maintenance oil

More information

Flow Divider Type MH2FA, Series 4X (Differential lock) Size 12 to 32 up to 420 bar up to 300 L/min

Flow Divider Type MH2FA, Series 4X (Differential lock) Size 12 to 32 up to 420 bar up to 300 L/min RE 8/0.98 8/0.9 Flow Divider Type MHF, eries X (Differential lock) ize to up to 0 bar up to 00 /min RE 8/0.98 Replaces: 0.9 Characteristics: Double-acting (dividing and summating) flow divider Fixed division

More information

40 to 300l/min 14MPa. wpressure adjustment is possible across a wide range, from 0.25 to 14MPa {2.5 to 143kgf/cm 2 }.

40 to 300l/min 14MPa. wpressure adjustment is possible across a wide range, from 0.25 to 14MPa {2.5 to 143kgf/cm 2 }. ounter alance eatures UR UR VV qhis modular valve is used to control actuator back pressure and for other pressure control valve applications. 0 to 00l/min a w adjustment is possible across a wide range,

More information

air and solenoid air operated 5/2-5/3 ISO 5599/01 - Size 2

air and solenoid air operated 5/2-5/3 ISO 5599/01 - Size 2 Series 4/PH MULTIFUNCTION SPOOL VALV air and solenoid air /-/ ISO 99/0 - Size ports / positions SPCIFICATIONS FLUID : or neutral gas, filtered, lubricated or not PRSSUR : 0,90 to + bar (can be used with

More information

SECTION 5 EDI Cartridge Valves

SECTION 5 EDI Cartridge Valves SECTION Cartridge Valves Make Model Page Way Pilot Operated Poppet Style Way Pilot Operated Double Lock Way Direct cting 3 Way -Position Direct cting 4 Way -Position Direct cting Spool Style 4 Way 3-Position

More information

29 188/ way Proportional Flow Control Valve Model 2 FRE 6./.,Series 2X. Ordering Code: Proportional Flow Control Valve 2 FRE 6 2X K4 V *

29 188/ way Proportional Flow Control Valve Model 2 FRE 6./.,Series 2X. Ordering Code: Proportional Flow Control Valve 2 FRE 6 2X K4 V * -way roportional low Control Valve Model RE./.,Series X Size... SI ( bar).... GM ( L/min) R 9 88/.98 R 9 88/.98 Replaces:.9 With pressure compensator for the control of an oil flow independent of pressure

More information

/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2

/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2 / way valves (solenoid actuated diaphragm with forced lifting) /4... Damped operation Operation without differential Suitable for vacuum igh flow rate For systems with low or fluctuating Brass body Wide

More information

The v alv e s with plug c onn e ctions in front are p erfera bly us e d on v alv e m o d ule s.

The v alv e s with plug c onn e ctions in front are p erfera bly us e d on v alv e m o d ule s. 3/2 and 5/2 way valves Flow rate: 130 l/min; M5 and Legris ø 4 port connection Advantages / Benefits Optimal system solutions due to high level of modularity Maintenance-free and no wear due to high level

More information

G 1/8 - G 3/8 G 1/2 - G 1 1/2. Poppet valves for compressed air 3/2

G 1/8 - G 3/8 G 1/2 - G 1 1/2. Poppet valves for compressed air 3/2 Poppet valves for compressed air Produced in a complete range of sizes from G 1/8 up to G 1 1/ these valves are particularly suitable for applications where high flow rates and high cycle rates are required.

More information

Attachments. T Type Interface: (T) M5 X 0.8, 1/ 8, 1/ 4, 3/ 8, 1/ 2 Makes it easy to diverge air out with T type interface

Attachments. T Type Interface: (T) M5 X 0.8, 1/ 8, 1/ 4, 3/ 8, 1/ 2 Makes it easy to diverge air out with T type interface ttachments Piping dapter M X 0.8, / 8, /, / 8, /, /, asy maintenance. Makes it possible to attach and detach equipment without removing piping. -0 Piping adapter To order piping adapter with bracket, the

More information

1) Actual pressure drop required for each metering land, up to the specified maximum flow rate is: Q ΔP actual. ) 2 PSI; (Q in GPM) actual Q rated

1) Actual pressure drop required for each metering land, up to the specified maximum flow rate is: Q ΔP actual. ) 2 PSI; (Q in GPM) actual Q rated tlog HY14-255/US echnicl Informtion Generl escription proportionl directionl control vlves re high performnce, two stge pilot operted solenoid vlves with electronic spool position feedck, nd on-ord integrted

More information

CAUTION. All safety information must be followed as provided in this Technical Sheet and in Service Manual RS

CAUTION. All safety information must be followed as provided in this Technical Sheet and in Service Manual RS peed Queen Domestic asher echnical nformation 0 V, 0 Hz Models 70 70 Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit.

More information

1/8 Solenoid Operated Directional Valves, DSG-01 Series. Max. Operating Pressure Kgf/cm {Spool Type 60 Only 250}

1/8 Solenoid Operated Directional Valves, DSG-01 Series. Max. Operating Pressure Kgf/cm {Spool Type 60 Only 250} /8 Solenoid Operted Directionl Vlves, DSG- Series WID RNG OF MODLSChoose the optimum vlve to meet needs from lrge selection ville. DIRCIONL CONROLS IC--- he DSG- series solenoid operted directionl vlve

More information

Max. Operating Pressure. Min. *2 Required Pilot Pres. Max. Pilot

Max. Operating Pressure. Min. *2 Required Pilot Pres. Max. Pilot DIRCIONL CONROLS Solenoid Controlled ilot Operted Directionl Vlves hese vlves re composed of solenoid operted pilot vlves nd pilot operted slve vlve. When solenoid is energised the pilot vlve directs the

More information

MONITOR REGULATOR SIZING AND OTHER CONSIDERATIONS

MONITOR REGULATOR SIZING AND OTHER CONSIDERATIONS MONITOR REGULATOR SIZING AND OTHER CONSIDERATIONS 6" 4" 6" 4" 4" 8" 4" 6" 6" 8" 6" 6" OGA 015 Regulator Fundamentals Seminar Monitor Regulator Sizing Theory FLOW in m out USTREAM MONITOR REGULATOR DOWNSTREAM

More information

Solenoid Pilot Actuated Valves. 501 Series 502 Series Directional Control Valve 503 Series

Solenoid Pilot Actuated Valves. 501 Series 502 Series Directional Control Valve 503 Series Solenoid Pilot ctuated Valves 0 Series 0 Series irectional ontrol Valve 0 Series Table of ontents 0/0/0 Series 0 Series Features and enefits Performance ata How to Order 0 Series Features and enefits Performance

More information

Elevator Control Valves

Elevator Control Valves E 00 Elevator ontrol alves IO 00 he LIN E 00 program includes the widest range of options offered to the elevator industry for high performance passenger service. Easy to install, E 00 s are smooth, reliable

More information

DRF RELIABILITY DATA

DRF RELIABILITY DATA Y K-ambda 9--0 X alculated values of - omponent derating -~ ain components temperature rise list -~ lectrolytic capacitor lifetime -9 Vibration test -0 bnormal est -~ hermal shock test - est results are

More information

Direct-operated 2/2-way solenoid valves Type EV210B

Direct-operated 2/2-way solenoid valves Type EV210B Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance

More information

Size A DIN EN

Size A DIN EN Size A DIN EN 70-0 Actuators 0 series DIN EN 70-0 +, + ow and high housing Degree of protection IP6 Wired versions Moulded versions Degree of protection IP67 Contacts Thread Cable outlet Ordering-No. Female

More information

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control AIR PREPARATION ELECTRONICALLY CONTROLLED PRESSRE REGLATING ALE (PROPORTIONAL PRESSRE REGLATING ALE) SERIES control Description Abb. Port size Recommended Type Data Sheet No. flow (l/min)* airfit tecno

More information

2.9. Namur Valves 2.9. page 175. Namur 1/4 also called Namur 1 in accordance to VDI / VDE Namur 1/2 also called Namur 2.

2.9. Namur Valves 2.9. page 175. Namur 1/4 also called Namur 1 in accordance to VDI / VDE Namur 1/2 also called Namur 2. 2.9 page 175 Namur 1/4 also called Namur 1 in accordance to VDI / VDE 3845. Namur 1/2 also called Namur 2. 2.9 Namur Valves + Selected models are available for low temperature application. Temperature-range:

More information

Smaller. Performance Characteristics. 0.5C (ma) [ C : Rated Capacitance(F)] (After 30 minutes' application of rated voltage : 2.7V) ESR ESR 2 U P±0.

Smaller. Performance Characteristics. 0.5C (ma) [ C : Rated Capacitance(F)] (After 30 minutes' application of rated voltage : 2.7V) ESR ESR 2 U P±0. LCRIC DOBL LAYR CAACIOR "VerCA " Radial Lead ype, Hig Voltage series Hig voltage type (.V). uitable for quick carge and discarge. Wide temperature range ( to + C). Compliant to te RoH directive (//). maller

More information

Solenoid valve Types EVR 2 - EVR 40

Solenoid valve Types EVR 2 - EVR 40 Data sheet Solenoid valve s EVR 2 - EVR 40 EVR is a direct or servo operated solenoid valve for liquid, suction, and hot gas lines with HCFC and HFC refrigerants. EVR valves are supplied complete or as

More information

Series Shockless Type Solenoid Operated / Solenoid Controlled Pilot Operated Directional Valves

Series Shockless Type Solenoid Operated / Solenoid Controlled Pilot Operated Directional Valves DIRCIL CROLS Series Shockless ype Solenoid Operted / Solenoid Controlled ilot Operted Directionl Vlves he G-Series incorporte electronic circuits o enle djustment of the spool shifting time. specil spool

More information

UPDATE. Summary of Specifications

UPDATE. Summary of Specifications UPDAE oroidal Design Screw Mount Lowest hermal Resistance Optimum Cooling Capability New Lower Profile s New eat Sink Mounting Kit RoS Compliant he series available in low profile sizes offers high capacitance

More information

P303 Pressure Regulator

P303 Pressure Regulator P0 Pressure Regulator Minimize Sudden Downstream Load Change Wide Pressure Ranges Integral Monitoring The BelGAS P0 and P0H gas pressure reducing regulators are available with a true monitor regulator,

More information

PRESSURE GAUGE SELECTORS

PRESSURE GAUGE SELECTORS PRESSURE GUGE SELECORS Gauge isolator valves are designed to protect pressure gauges from pressure shocks when the pressure reading is not required; after each reading setting the selector to the closed

More information

Normally Closed (N.C.), Normally Open (N.O.), Common (C.O.)

Normally Closed (N.C.), Normally Open (N.O.), Common (C.O.) Series VVX// The models VX// have been revised. For details, please refer to catalog no. ES0-A. Similar updating Normally Closed (N.C.), Normally Open (N.O.), Common (C.O.) Courtesy of Steven Engineering,

More information

Universal type Port size: M5, Rc1/8, Rc1/4. Max. working. pressure

Universal type Port size: M5, Rc1/8, Rc1/4. Max. working. pressure irect acting port solenoid valve for compressed air, manifold (special purpose valve) Series Universal type Port size: M, Rc/, Rc/ Refer to nding for more details. JIS symbol ommon supply / common exhaust

More information

Features: Specification. Model. Acting type. Tube I.D.(mm) Port size. No. of port. Medium Operating pressure range

Features: Specification. Model. Acting type. Tube I.D.(mm) Port size. No. of port. Medium Operating pressure range & F * eries to 3mm ore Features: qual forces on both ends of the piston. Force connection direct, torque safe. agnetic piston standard. % spacesavings. nd caps with 3 air connections and adjustable cushioning.

More information

ISO 9001 TOP MOUNT SPOOL VALVES TOP MOUNT SPOOL VALVES

ISO 9001 TOP MOUNT SPOOL VALVES TOP MOUNT SPOOL VALVES ISO 900 OP MOUN SPOOL VALVES OP MOUN SPOOL VALVES OP MOUN SPOOL VALVES MEHANIALLY LOKED AIR LINE SEDIMEN IPED AAY NO SPIRAL IS NO EXRUSION DESIGN FEAURES VALVES Balanced spool construction allows ports

More information

F01 D S F01 F01 F01. Vacuum Ejector Box Type (Built in Silencer)/Body Ported Type Series ZH. How to Order. Product Recommendation.

F01 D S F01 F01 F01. Vacuum Ejector Box Type (Built in Silencer)/Body Ported Type Series ZH. How to Order. Product Recommendation. 2 Series ZH jector jector ox Type (uilt in Silencer)/ody Ported Type Series ZH eatures Symbol ompact and lightweight desing. hoice of nozzle diameters. Standard or low vacuum pressure options. One touch

More information

2/2-3/2 POPPET VALVES FOR VACUUM (1/8"-6/4") Series AG

2/2-3/2 POPPET VALVES FOR VACUUM (1/8-6/4) Series AG 2/2/2 POPPET VLVES FOR VCUUM (1/"/") Series G G / 1/2 complete range: / / G/ G/ 1/2 Original Univer poppet system appreciated for decades Servoassisted version complete range of solenoid valves and valves

More information

Softstarter range type PSD & PSDH

Softstarter range type PSD & PSDH Softstarter range type SD & SDH Description Softstarters type S D and S DH ABB s solid state starter range is used when it is important to have a smooth start-up of various types of motor drives. Instead

More information

Cooling Water Flow Regulator

Cooling Water Flow Regulator Temperature controlled, indirectly and directly actuated diaphragm valves / seat valves Port size G 3/8 to G DN 0 to DN 0 ontinuous regulation High accuracy No auxiliary energy required Technical data

More information

ISO mm ISO mm. Nl/min. Nl/min. Nl/min. Nl/min. ISO /2 Distributors. ISO Interface. OVERSIZED interface (UNIVER original)

ISO mm ISO mm. Nl/min. Nl/min. Nl/min. Nl/min. ISO /2 Distributors. ISO Interface. OVERSIZED interface (UNIVER original) ISO 154071/ Distributors E Integrated electrical connection (ISO 15407/) B M1 connector (Automotive) A Single electrical connection (ISO 15407/1) A Pneumatic connection (ISO 15407/1) ISO 0 ISO Interface

More information

2-way proportional throttle valve for block installation

2-way proportional throttle valve for block installation -way proportional throttle valve for block installation Types FES; FESE Sizes to Component series X Maximum operating pressure bar Maximum flow 800 l/min at Δp = 0 bar Table of contents Contents Page Features

More information

4/3-way servo solenoid directional control valves with electrical position feedback (Lvdt DC/DC) (ruggedized design)

4/3-way servo solenoid directional control valves with electrical position feedback (Lvdt DC/DC) (ruggedized design) 4/3-way servo solenoid directional control valves with electrical position feedback (Lvdt DC/DC) (ruggedized design) Type 4WRL10...25 Sizes (N) 10, 16, 25 Unit series 3 Maximum working pressure P,, 350

More information

Safety valve with unit approval type MV..X.., SV..X..

Safety valve with unit approval type MV..X.., SV..X.. Safety valve with unit approval type MV..X.., SV..X.. Operating pressure p max = 0 bar Flow Q max = 0 lpm Safety valve type CMVX 2.. with unit approval see D 77 TÜV These safety valves are intended for

More information

ENERGY CONVERSION IN A FLUID POWER SYSTEM. Preview GRC. mechanical friction. File name GA: FLOW GENERATING GROUP. traen_eng GRC: CONTROL GROUP

ENERGY CONVERSION IN A FLUID POWER SYSTEM. Preview GRC. mechanical friction. File name GA: FLOW GENERATING GROUP. traen_eng GRC: CONTROL GROUP PRIME MOVER (electric motor, IC engine) ENERGY CONVERSION IN FLUID POWER SYSTEM P P mech mech (exended) P P (useful) hydr hydr rotary shaft G M, Q, Q, M, F, v P W GRC P W GU oil ies oil ies rotary shafts,

More information

Variable Displacement Plug-In Motor A6VE. Series 6, for open and closed circuits Axial tapered piston, bent axis design

Variable Displacement Plug-In Motor A6VE. Series 6, for open and closed circuits Axial tapered piston, bent axis design rueninghaus Hydromatik Series 6, for open and closed circuits xial tapered piston, bent axis design Size 28...20 Nom. pressure up to 400 bar Peak pressure up to 40 bar RE 9606/0.97 RE 9606/0.97 replaces

More information

Manually Operated Directional Valves DMT- 03 / 06 / 10 DMG-01 / 03 / 04 / 06 / 10 Thread Connection / Sub-plate Mounting.

Manually Operated Directional Valves DMT- 03 / 06 / 10 DMG-01 / 03 / 04 / 06 / 10 Thread Connection / Sub-plate Mounting. Manually Operated Directional s DM- / / DMG- / / / / hread Connection / Mounting Specifications hreaded Connections Numbers DM--C - DM--D - DM--D - DM--B - DM- -C - DM- -D - DM- -D - ( ) (.) (.) (.) (.)

More information

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE) 4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE) RE 9035/. Replaces: 05. 1/1 Type 4WRPEH 6 Size 6 Unit series X Maximum

More information

4KB1/2/3/4 Series. Applicable cylinder bore size: 20 to 160mm. Pilot operated soft spool valve. Compressed air

4KB1/2/3/4 Series. Applicable cylinder bore size: 20 to 160mm. Pilot operated soft spool valve. Compressed air Discrete vlve Su se porting, port pilot operted vlve K1/2// Series pplicle cylinder ore size: 20 to 0mm CD DT VILLE. JIS symol port vlve 2position single port vlve 2position doule port vlve position ll

More information

VALVES B D E B D A. ISO /2 Valves CHARACTERISTICS CODIFICATION KEY. BD 18 mm. BD 26 mm

VALVES B D E B D A. ISO /2 Valves CHARACTERISTICS CODIFICATION KEY. BD 18 mm. BD 26 mm BD ISO 15071/ Valves CHARACTERISTICS Ambient temperature Fluid Commutation system Max pressure Connections Nominal bore (mm) Nominal flow rate (Nl/min) Valve body Seals Spool Electropilot/Coil Voltage

More information

MX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E

MX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E OMPT ND USER FRIENDLY MX Series Metal Tube Type Variable rea Flowmeter OUTLINE MX Series flowmeter is the metal tube type variable area flowmeter having the unified face-to-face dimension. The compact

More information

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application Type 2657...59 DN 10 up to 80 mm; Plastic; 2/2 way dvantages/benefits ntegrated pilot valves, position feed-back and limit switches available Customized system solutions with Burkert valves & sensors With

More information

Radial piston pump type R and RG

Radial piston pump type R and RG Radial piston pump type R and RG with radial piston pump acc. to D 6010 and several pressure outlet Operating pressure p max = 700 bar Delivery flow Q max = 76.0 lpm (at 1450 rpm) Radial piston pumps type

More information

Pilot Operated Pressure Relief Valves with 2 or 3 Pressure Ratings Type DB 3U, Series 5X

Pilot Operated Pressure Relief Valves with 2 or 3 Pressure Ratings Type DB 3U, Series 5X ilot Operted ressure Relief Vlves with or ressure Rtings ype D U, Series RE 6/.9 RE 6/.9 Sizes,, Up to r Up to 6 L/min Replces: Specil fetures: Suplte mounting Mounting to DIN form E, Connection pltes

More information

Karad-Dhebewadi Road Karad INDIA

Karad-Dhebewadi Road Karad INDIA MRR MDL K372LG-BXXX BLL MRL B230, B231, B130 Karad-Dhebewadi Road Karad - 415 110 D ote ales compressor drawing number and compressor model name are the same. 25-1206- 1 0591urrent Last Model ame K372LG-BXXX

More information

HRN/HRN-C Series Hydraulic Vane Rotary Actuators

HRN/HRN-C Series Hydraulic Vane Rotary Actuators HRN/ Hydraulic Vane Rotary Actuators Vane Actuators Tork-Mor HRN Contents Features... 2 Ordering Information... Engineering Data / Specifications... Dimensions... Features... 1 Ordering Information...12

More information

Model Selection 1. Process Valves. Air. Vacuum

Model Selection 1. Process Valves. Air. Vacuum Process Valves Model Selection For product specifications such as maximum operating pressure differentials and operating temperature ranges, refer to the relevent pages of each product. Air One-touch fittings

More information

Direct-operated 2/2-way compact solenoid valves Type EV210A

Direct-operated 2/2-way compact solenoid valves Type EV210A Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together

More information

Emerson Climate Technologies (India) Private Limited Karad Dhebewadi Road Karad INDIA

Emerson Climate Technologies (India) Private Limited Karad Dhebewadi Road Karad INDIA merson limate echnologies (ndia) rivate Limited MRR MDL merson limate echnologies (ndia) rivate Limited Karad Dhebewadi Road Karad - 415 110 D ote: ales compressor drawing number and compressor model name

More information

2/3 Port Valves for Fluid Control Model Selection 1

2/3 Port Valves for Fluid Control Model Selection 1 / Port Valves for Control Model Selection Model Selection For product specifications such as maximum operating pressure differentials and operating temperature ranges, refer to the relevent pages of each

More information

4/3, 4/2 and 3/2 directional valve with fluidic actuation

4/3, 4/2 and 3/2 directional valve with fluidic actuation 4/3, 4/2 nd 3/2 directionl vlve with fluidic ctution RE 22282/04.10 Replces: 08.08 1/12 ype W, WH Size 6 Component series 6X (W), 5X (WH) Mximum operting pressure 315 r [4569 psi] Mximum flow 60 l/min

More information

2017 HYDAC International GmbH. All rights reserved, also regarding any disposal, VT-info exploitation, 51A new reproduction, series 4WE10

2017 HYDAC International GmbH. All rights reserved, also regarding any disposal, VT-info exploitation, 51A new reproduction, series 4WE10 2017 HYDAC International GmbH. All rights reserved, also regarding 2018-04 any disposal, VT-info exploitation, 51A new reproduction, series 4WE10 SPECIFICATIONS pmax. = 350 bar Qmax. = 160 l/min direct

More information

CV3000 Series. Characterized Insert Control Valves

CV3000 Series. Characterized Insert Control Valves CV3000 Series Characterized Insert Control Valves The CV3000 Series is a v-type control valve for precise control allowing high pressure drop capability with straight-through flow and bubble-tight shut

More information

Our policy is one of continued research and development. We therefore reserve the right to

Our policy is one of continued research and development. We therefore reserve the right to D/99000, D/99000 ompact cylinders on-magnetic and magnetic piston Double acting Ø 12 to 160 mm ight weight ompact design, which is considerably shorter than IS/VDA or FA equivalent. ow friction characteristics

More information

M O D U L E - 3A Model A10V0 Piston Pump Manual A10V0 PUMP. Features

M O D U L E - 3A Model A10V0 Piston Pump Manual A10V0 PUMP. Features T E C H N I C A L I N F O R M A T I O N M A N U A L F O R T H E A 1 0 V 0 V A R I A B L E D I S P L A C E M E N T P U M P S A10V0 PUMP Features High Efficiency through load sensing (= fuel savings) Maximum

More information

MN4TB1/2 Series. Applicable cylinder bore size: ø20 to ø80

MN4TB1/2 Series. Applicable cylinder bore size: ø20 to ø80 M port vlve DIN ril mount MN/ Series pplicle cylinder ore size: ø0 to ø0 MN W *0E JIS symol port vlve -position single solenoid -position doule solenoid -position ll ports closed -position //R connection

More information

Check-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD

Check-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD Check-Q-meter RE /0.0 /0 Replaces: 09.9 Type FD Nominal size... Series ax. Operating pressure 0 bar ax. Flow 0 l/min K9/ Table of contents Contents Page Features Functions Ordering details Symbols Functional

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T... Magnetic and Hydraulic-Magnetic Circuit Breaker 830-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of

More information

2/3 Port Valves for Fluid Control Model Selection 1

2/3 Port Valves for Fluid Control Model Selection 1 / Port Valves for Control Model Selection Model Selection For product specifications such as maximum operating pressure differentials and operating temperature ranges, refer to the relevent pages of each

More information

4.4 E 60/E 100 ELECTRIC ACTUATORS E 60/E 100 TECHNICAL DATA E 60 GENERAL APPLICATIONS E 100 FEATURES. Valve interface: EN ISO 5211

4.4 E 60/E 100 ELECTRIC ACTUATORS E 60/E 100 TECHNICAL DATA E 60 GENERAL APPLICATIONS E 100 FEATURES. Valve interface: EN ISO 5211 ELETRI ATATORS E 0/E 0 TEIAL DATA Valve interface: E ISO Type E 0 A ) E 0 A ) * Operating time (0 0 ) ominal torque ominal current Starting current s 0 m 0, A A s 0 m 0, A 0, A s 0 m A A s 00 m A A s 00

More information

Standard specifications ZX165UFE02001

Standard specifications ZX165UFE02001 Standard specifications ZXUF000 May, 0 KAWASAKI HAVY INDUSTRIS, LTD. ROBOT DIVISION Materials and specifications are subject to change without notice. Specification : (Arm): (Controller): 00-DA 0-00DA

More information

HYDRAULIC POWER PACKS

HYDRAULIC POWER PACKS HYDRULI POWER PKS Typical Electric Wiring Diagram (D Pack) HYDRULI POWER PKS Hydraulic Pump Hydraulic Valve Hydraulic ccessory pplication Oder ode System Power Packs SISSOR LIFT POST LIFT JP0 SISSOR LIFT

More information

Pilot operated 2 port solenoid valve (general purpose valve) Standard specifications NC (normally closed) type C C. 2 /s) Starting

Pilot operated 2 port solenoid valve (general purpose valve) Standard specifications NC (normally closed) type C C. 2 /s) Starting 21/22 Series (general purpose valve) 21/22 Series NC (normally closed) type, NO (normally open) type Port size: Rc1 1/4 to Rc2, 32 to 50 flange iaphragm structure JIS symbol 21: Common specifications Item

More information

PART II. Fluid Mechanics Pressure. Fluid Mechanics Pressure. Fluid Mechanics Specific Gravity. Some applications of fluid mechanics

PART II. Fluid Mechanics Pressure. Fluid Mechanics Pressure. Fluid Mechanics Specific Gravity. Some applications of fluid mechanics ART II Some applications of fluid mechanics Fluid Mechanics ressure ressure = F/A Units: Newton's per square meter, Nm -, kgm - s - The same unit is also known as a ascal, a, i.e. a = Nm - ) English units:

More information

MPT Multifunction Multiport

MPT Multifunction Multiport MP Multifunction Multiport Maximum pressure 8 bar F l o w r a t e s t o 0 0 l / m i n echnical data housing (Materials) ead: luminium Cover: Nylon Bowl: Nylon Pressure Working pressure: 8 bar emperature

More information

Directional spool valve type SWPN Nom. size 6 or 10 conforming DIN

Directional spool valve type SWPN Nom. size 6 or 10 conforming DIN Directional spool valve type SWPN Nom. size 6 or 10 conformg DIN 24 340 Max. pressure Max. flow = 350 bar = 150 lpm 1. General The valves illustrated here are directly actuated directional spool valves

More information

Symbol Parameter Test Conditions Value Unit Sxx15L T C. = 90 C 15 RMS on-state current Sxx16R = 90 C 9.5 I T(AV) Sxx16R

Symbol Parameter Test Conditions Value Unit Sxx15L T C. = 90 C 15 RMS on-state current Sxx16R = 90 C 9.5 I T(AV) Sxx16R Sxx15x & Sxx16x Series RoHS Description Excellent unidirectional switches for phase control applications such as heating and motor speed controls. Standard phase control SRs are triggered with few milliamperes

More information

Solenoid valves Type EVR 2 g 40 NC/ NO New EVR 6 with Steel cover design

Solenoid valves Type EVR 2 g 40 NC/ NO New EVR 6 with Steel cover design MAKING MODERN LIVING POSSIBLE Technical brochure Solenoid valves EVR 2 g 40 NC/ NO New with Steel cover design EVR is a direct or servo operated solenoid valve for liquid, suction, and hot gas lines with

More information

The 505F Series 3/4/5-Way Ball Valve. Standard Features and Benefits. Operating Conditions. Specifications. Options

The 505F Series 3/4/5-Way Ball Valve. Standard Features and Benefits. Operating Conditions. Specifications. Options The 505F Series //5-Way Ball Valve The 505F is a true multi-way ball valve with balanced fourseat construction. This full port valve is available in a variety of flow plans which can replace multiple two-way

More information

V5013B-F Three-Way Mixing & Diverting Valves

V5013B-F Three-Way Mixing & Diverting Valves VB-F Three-Way Mixing & Diverting Valves FEATRES SPECIFICATION DATA Mixing or diverting models Bronze body with female, screwed-end connections or cast iron body with flanged-end connections Stainless

More information

Type M4 - SON - SO - MS

Type M4 - SON - SO - MS 9. REV. Type M - SON - SO - MS Aircaps Tank venting and water excluding aircaps. For installation on service tank air pipes. Inerted void spaces and ballast tanks In order to maintain inert gas pressure

More information

Directional spool valves type UREP10 electrohydraulically

Directional spool valves type UREP10 electrohydraulically Directionl spool vlve type URE0 electro-hydruliclly operted NS0 up to 3,5 M up to 50 D SHEE - SERVICE MNU NUL dm 3 /min WK 42 60 05.202 LICION Directionl spool vlves type URE0 electrohydruliclly operted

More information

Emerson Climate Technologies (India) Limited Karad Dhebewadi Road Karad INDIA

Emerson Climate Technologies (India) Limited Karad Dhebewadi Road Karad INDIA merson limate echnologies (ndia) Limited MRR MDL R53KQM-D-XXX (@ 50 Hz) BLL MRL 101, 102, 103, 201, 202, 203 ote : ales compressor drawing number and compressor model name are the same. 1 01 urrent merson

More information

hard anodized aluminum extrusion die cast aluminium acetalic resin nickel plated steel die cast aluminium nitrile rubber stainless steel 3 Version

hard anodized aluminum extrusion die cast aluminium acetalic resin nickel plated steel die cast aluminium nitrile rubber stainless steel 3 Version YR Pneumatic actuators for process automation Pneumatic connections configuration: NMUR interface V/VE Top pinion: V/VE Holes for sensor box connection: V/VE ottom holes for connecting valves: SO Single

More information

Pneumatic Valves. Valve Actuators

Pneumatic Valves. Valve Actuators Air Preparation Units Symbol Description Pneumatic Valves Symbol Description Symbol Cylinders Description Filter / Separator with manual drain 3-Position, 4-Way, APB ports closed, center pos. Standard

More information

MPF SERIES RETURN FILTER

MPF SERIES RETURN FILTER MPF SERIES The series of filters MPF has specifically been designed for use on mobile applications, agricultural machinery and power units. The MPF filter range is suitable for flow rates up to 750 l/min.

More information

Time - timing relays 1 Industrial relays, solid state output, width 22.5 mm

Time - timing relays 1 Industrial relays, solid state output, width 22.5 mm haracteristics Zelio ime - timing relays Industrial relays, solid state output, width. mm Presentation 08 he E9 range of relays is designed for simple, repetitive applications with short and intensive

More information

98 Series Backpressure Regulators and Relief Valves

98 Series Backpressure Regulators and Relief Valves 9 Series Backpressure Regulators and Relief Valves Bulletin.:9 November 09 W TYPE 9H W TYPE 9LD Figure. Typical 9 Relief Valves Introduction W TYPE 9HD The 9 Series (Figure ) is used for backpressure or

More information

Target Insertion Flowmeter

Target Insertion Flowmeter Principle of Operation Flow is measured in terms of dynamic force acting on a target (solid disk) in the flow stream. Hermetically sealed, bonded strain gages in a bridge circuit configuration mounted

More information

Advanced modeling of automotive variable displacement vane oil pumps

Advanced modeling of automotive variable displacement vane oil pumps Pierburg Pump Technology Italy S.p.a. Advanced modeling of automotive variable displacement vane oil pumps Italia GT-SUITE Conference 2017 Torino, 10 May 2017 Authors: Diego Saba, Matteo Gasperini, Gaia

More information

THIS MANUAL IS THE PROPERTY OF THE OWNER. PLEASE BE SURE TO LEAVE IT WITH THE OWNER WHEN YOU LEAVE THE JOB.

THIS MANUAL IS THE PROPERTY OF THE OWNER. PLEASE BE SURE TO LEAVE IT WITH THE OWNER WHEN YOU LEAVE THE JOB. -. September, 9 II DIMS gas-fired, power vented and separated combustion unit heaters for models HD/HDB, HDS/HD, PS/BS, P I. Fuel supply shall be shut-off and the electrical power disconnected before proceeding

More information

LITTLE CHAMP TM POWER UNITS 3 to 25 Gallon Reservoir Capacity L I T T L E C H A M P TM P O W E R U N I T S

LITTLE CHAMP TM POWER UNITS 3 to 25 Gallon Reservoir Capacity L I T T L E C H A M P TM P O W E R U N I T S LILE HM M OWER UNIS 3 to Gallon Reservoir apacity L I L E H M M O W E R 80 U N I S 500 0 1000 bar 100xka 1500 2000 M-10N LILE HM M OWER UNIS 3 to Gallon Reservoir apacity Little hamp M ower Units are designed

More information

Cartridge Valves Technical Information. Quick reference

Cartridge Valves Technical Information. Quick reference Quick reference Contents CPF0... 8. CP600-5... 8. CP60-5... 8. 066 handle kit... 8.5 MP06... 8.6 MP... 8.6 X05-FD0 Traction manifold... 8.9 X05-FD6 Traction manifold... 8.0 X05-FD0 Traction manifold...

More information

Hydraulic (Fluid) Systems

Hydraulic (Fluid) Systems Hydraulic (Fluid) Systems Basic Modeling Elements Resistance apacitance Inertance Pressure and Flow Sources Interconnection Relationships ompatibility Law ontinuity Law Derive Input/Output Models ME375

More information

MELCOR Analysis of Helium/Water/Air Ingress into ITER Cryostat and Vacuum Vessel

MELCOR Analysis of Helium/Water/Air Ingress into ITER Cryostat and Vacuum Vessel TM-2926-1 MELCOR Analysis of Helium/Water/Air Ingress into ITER Cryostat and Vacuum Vessel C. H. Sheng and L. L. Spontón Studsvik Nuclear AB, SE-611 82 Nyköping, Sweden chunhong.sheng@studsvik.se Abstract

More information

Flow Measurement in Pipes and Ducts COURSE CONTENT

Flow Measurement in Pipes and Ducts COURSE CONTENT Flow Measurement in Pipes and Ducts Dr. Harlan H. Bengtson, P.E. COURSE CONTENT 1. Introduction This course is about measurement of the flow rate of a fluid flowing under pressure in a closed conduit.

More information

Model Selection 1. Process Valves

Model Selection 1. Process Valves Process Valves Model Selection For product specifications such as maximum operating pressure differentials and operating temperature ranges, refer to the relevent pages of each product. Air, Inert gas

More information