Time - timing relays 1 Industrial relays, solid state output, width 22.5 mm

Size: px
Start display at page:

Download "Time - timing relays 1 Industrial relays, solid state output, width 22.5 mm"

Transcription

1 haracteristics Zelio ime - timing relays Industrial relays, solid state output, width. mm Presentation 08 he E9 range of relays is designed for simple, repetitive applications with short and intensive cycles because their solid state output provides very high electrical durability. Each relay has a single timing range. Each relay has a wide voltage range from to 0 V. he range comprises 9 references with model types: b E9 A: function A, b E9 A: function, b E9 MS: multifunction A, H,, i. hese products have a transparent, hinged flap on their front face to avoid any accidental alteration of the settings. his flap can be directly sealed. Environment onforming to standards IE 8-, EN 8- Product certifications e marking SA, G pending. Zelio ime timing relays conform to European regulations relating to e marking Ambient air temperature around the device Permissible relative humidity range Storage Operation onforming to IE % Environmental class Vibration resistance onforming to IE 08--, a = 0. ms 0 to Hz Shock resistance onforming to IE gn - ms Degree of protection asing IP 0 erminals IP 0 Degree of pollution onforming to IE 0- Overvoltage category onforming to IE 0- III ated insulation voltage onforming to IE V 0 onforming to SA V 00 est voltage for insulation tests Dielectric test kv. Shock wave kv.8 Voltage limits Power supply circuit 0.8. c Frequency limits Power supply circuit Hz 0/0 ± % Disconnection value Power supply circuit > 0. c Mounting position without derating abling Maximum c.s.a. In relation to normal Any position vertical mounting plane Flexible cable without cable end mm x. Flexible cable with cable end mm x. ightening torque N.m 0.. Immunity to electromagnetic interference (EM) (application class conforming to EN 8-) Electrostatic discharge onforming to IE evel ( kv contact, 8 kv air) Electromagnetic fields onforming to IE evel (0 V/m) Fast transients onforming to IE evel ( kv) Shock waves onforming to IE evel ( kv) adiated and conducted emissions ISP ISP Group class A lass A eferences : page 0 Dimensions : page 0 page 8

2 haracteristics (continued) Zelio ime - timing relays Industrial relays, solid state output, width. mm iming relay type Supply characteristics E9 A On-delay E9 A Off-delay E9 MS Multifunction Supply voltage V a/c 0 a 0 a/c 0. See page 0 Voltage limits Of the control circuit 0.8. n Frequency Hz 0 0 ± % ontrol contact Mechanical only In series Between Y and In series Maximum length of From contact to E9 m 0 connecting cable ontrol input consumption Input Y ma iming characteristics Setting accuracy < ± 0 % epeat accuracy < % Minimum reset time After the time delay period ms 00 Minimum switching time ms 0 Maximum immunity to microbreaks emperature drift During the time delay period ms After the time delay period ms 0. % per degree centigrade Switching characteristics (solid state type) Maximum continuous current At ambient temperature: 0 A 0.7 (minimum 0 ma) Maximum overload current VDE 0 part. 0, A for 0 ms.8./lass II Maximum voltage drop losed state V (at 0.7 A) eakage current Open state ma Maximum dissipated power W.. Derating For temperature > 0 ma Without Electrical durability In millions of operating cycles > 00 eferences : page 0 Dimensions : page 0 page 9

3 Functions, references, dimensions Zelio ime - timing relays solid state output, width. mm Solid state output Function diagrams Function A Function Function H Delay on energisation iming after opening of control contact iming on energisation Function D Symmetrical flashing, start with output in rest position Function Di Symmetrical flashing, start with output in operating position eferences Functions A A, H, D, Di Voltages c or a 0 V p p (A) a 0 V p p (H, D, Di) iming ranges 0. s 0 s E9 MW E9 MW7 E9 MSMW 0. s 0 s E9 AMW E9 AMW7 s 00 s E9 MW E9 MW7 E9 MSMW 0 s 0 min E9 AMW E9 AMW7 Weight (kg) Dimensions ail mounting Screw fixing , 8 haracteristics : pages 8 and 9 page 0

4 Schemes Zelio ime - timing relays solid state output, width. mm erminal blocks E9 A E9 A E9 MS X Y X X X ecommended application schemes E9 A E9-A oad he timing relay is placed in series, with the load whose energisation is to be delayed on one side and switch on the other side. he mains supply may be a.c. or d.c. and the voltage may be between V and 0 V. See function diagram on page opposite. Supply a or c E9 A E9-A oad he timing relay is placed in series with the load whose de-energisation is to be delayed. Switch is connected to terminals Y and of the timing relay, and terminal is connected to the mains supply, as indicated in the diagram opposite. he device is operated from an a.c. mains supply whose voltage is between V and 0 V. See function diagram on page opposite. Y Supply a E9 MS Delay on energisation Function A iming on energisation Function H Selection of the timing range X X E9-MS oad X X X E9-MS oad X-X not linked: range s 00 s (factory configuration) X-X linked: range 0. s 0 s Supply a or c Supply a ink to be made between terminals X and X Symmetrical flasher, start with output in rest position Function D Symmetrical flasher, start with output in operating position Function Di X X X X oad X X X oad E9-MS E9-MS Supply a Supply a ink to be made between terminals X and X on one side ink to be made between terminals X and X and between X and X on the other side Note : For supply voltages greater than 0 V, the rated voltage of the load is equal to the supply voltage. For a supply voltage of V, the voltage drop within the E9 relay must be taken into account (about V); a coil with a nominal voltage of V must therefore be selected for the load. haracteristics : pages 8 and 9 Dimensions : page 0

5 haracteristics Zelio ime - timing relays relay output, width. mm Presentation 087 he E7 range of relays, with only references, covers all timing applications. hese relays offer multi-range timing from 0 ms to 00 h. hey are multivoltage. hree models combine several different functions: multifunction relays. hese products have a transparent, hinged flap on their front face to avoid any accidental alteration of the settings. his flap can be directly sealed. Environment onforming to standards IE 8-, EN 8- Product certifications SA, G pending, e marking Zelio ime timing relays conform to European regulations relating to e marking Ambient air temperature around the device Permissible relative humidity range Storage Operation onforming to IE % Environmental class Vibration resistance onforming to IE 08--, a = 0. ms 0 to Hz Shock resistance onforming to IE gn - ms Degree of protection asing IP 0 erminals IP 0 Degree of pollution onforming to IE 0- Overvoltage category onforming to IE 0- III ated insulation voltage onforming to IE V 0 Between contact circuit and onforming to SA power supply or between contact V 00 circuit and control inputs est voltage for insulation tests Dielectric test kv. Shock wave kv.8 Voltage limits Power supply circuit 0.8. c Frequency limits Power supply circuit Hz 0/0 ± % Disconnection value Power supply circuit > 0. c Mounting position without derating abling Maximum c.s.a. In relation to normal Any position vertical mounting plane Flexible cable without cable end mm x. Flexible cable with cable end mm x. ightening torque N.m 0.. Immunity to electromagnetic interference (EM) (application class conforming to EN 8-) Electrostatic discharge onforming to IE evel ( kv contact, 8 kv air) Electromagnetic fields onforming to IE evel (0 V/m) Fast transients onforming to IE evel ( kv) Shock waves onforming to IE evel ( kv) adiated and ISP Group class A conducted emissions ISP lass A onsumption a 0/0 Hz c Average consumption V 8 V 0 V 0 V V 8 V 0 V 0 V E7-ppB VA W 0.. E7-ppB and E7-ppB VA..8. W 0.8. E7-ppppMW () VA.. W. () E7-BppMW: current peak on energisation = A / 0 ms. eferences : pages 0 to 8

6 haracteristics (continued) Zelio ime - timing relays relay output, width. mm iming characteristics Setting accuracy As % of the full-scale value ± 0% epeat accuracy ±0.% Influence of voltage In the voltage range, 0.8. n <0.% Influence of temperature < 0.07 %/ Immunity to microbreaks ms Minimum control pulse ms 0 (except E7-BpMW: s) eset time ms 0 Output circuit characteristics Maximum switching voltage V z 0 Mechanical durability In millions of operating cycles 0 urrent limit Ith A 8 (except E7-BppMW: A) ated operational limits at 70 V V 0 V onforming to IE 097--/99 A- A and VDE 00 D- A Minimum switching capacity V/0 ma ontact material 90/0 nickel silver (except E7-BppM: gold flashed silver alloy) emote control input characteristics Maximum voltage Signal delivered by control inputs YZ, XZ, XZ No galvanic insulation between these inputs and the supply Potentiometer for connection between terminals ZZ, ZZ Applicable to inputs YZ, XZ, XZ V 0 Switching current ma < Maximum distance m 0 ompatibility /-wire PNP and NPN elemecanique sensors or other sensors without an internal load ype inear at ± 0 % esistance kω 7 ± 0 % Power W 0. Maximum distance m by shielded cable: shielding linked to terminal Z a.c. load d.c. load urve urve oad limit curve Electrical durability of contacts on resistive load in millions of operating cycles eduction factor k for inductive loads (applies to values taken from durability curve ) Millions of operating cycles 0 0, A 0, urrent broken in A eduction factor k 0,9 0,8 0,7 0, 0, 0, 0, 0,8 0, 0, 0, 0, 0, Power factor on breaking (cos ϕ) Voltage in V A 0 0, 0, 0, 0 0 urrent in A A E7-BppMW A E7-BppMW / = 0 ms / with load protection diode esistive load Example: An -F8 contactor supplied with V/0 Hz for a consumption of VA or a current consumption equal to 0. A and cos ϕ = 0.. For 0. A, curve indicates a durability of approximately. million operating cycles. E7 As the load is inductive, it is necessary to apply a reduction coefficient k to this number of cycles as indicated by curve. For cos ϕ = 0.: k = 0. he electrical durability therefore becomes:. 0 operating cycles x 0. = operating cycles. eferences : pages 0 to 9

7 Functions, references, dimensions, schemes Zelio ime - timing relays relay output, width. mm Output /O contact Multiple timing ranges Function diagrams Function A Function At Function Aw Delay on energisation Delay on energisation with memory Off-delay on energisation or on opening of control contact t t Function Ac iming after closing and opening of control contact G = t t Function Ak Asymmetrical On-delay and Off-delay with external control G t t t' t' t t t' t' = t t = t t a = t t r = t t eferences Functions A A, Aw, At Ac Ak iming ranges 0.0 s 00 h 0 ranges 0.0 s 00 h 0 ranges 0.0 s 00 h 0 ranges 0.0 s 00 h 0 ranges Voltages c or a V p p p p a 0 0 V p p p p a or c 8 V p p p c or a 0 V eferences E7 B E7 MB E7 MB E7 MVB Weight (kg) Dimensions and connection schemes Dimensions ail mounting 80 Screw fixing 89, 8, Ø haracteristics : pages 8 and 9 pages and 0

8 Function Function Function H Function Ht Function W Delay on de-energisation (without auxiliary supply) iming after opening of control contact iming on energisation iming on energisation with memory On-delay after opening of control contact > s () t t t t Function D Function Di Function Function i Function t Symmetrical flashing, Symmetrical flashing, Asymmetrical flashing, Asymmetrical flashing, Asymmetrical flashing start with output in start with output in start with output in start with output in with partial stop of timing rest position operating position rest position operating position / inst. () r a a r G t t t t r = t t a = t t () If the device has been stored, de-energised, for more than a month, it must be energised for about seconds in order to activate it. Subsequently, it only takes second to start the time delay. d If this time is not complied with, the relay remains energised indefinitely. () timed outputs (/) or timed output () and instantaneous output ( inst.) H Ht, W D, i, t A,, H, W, D, Di 0.0 s 0 min 7 ranges 0.0 s 00 h 0 ranges 0.0 s 00 h 0 ranges 0.0 s 00 h 0 ranges 0.0 s 00 h 0 ranges 0.0 s 00 h 0 ranges 0.0 s 00 h 0 ranges p p p p p p p p p p p p p p p p p E7 BMW E7 B E7 PEB E7 PMB E7 B E7 VB E7 MB E7 MB low level contact onnection schemes E7 B E7 BMW E7 PEB E7 MB, E7 B E7 MB, E7 PMB B B B Z B E7 MB E7 MVB B Z B E7 B B E7 VB B Z Z B B 8 8 B 8 B B 8 B B 8 B 8 B B X Y Z 8 X Y Z 8 8 X X Z 8 haracteristics : pages 8 and 9 Dimensions : page 0 pages and

9 Functions, references, dimensions, schemes Zelio ime - timing relays relay output, width. mm Output /O contacts Multiple timing ranges Function diagrams Function A Function Ac Function Delay on energisation iming after closing and opening of control contact iming after opening of control contact / inst. () Function Delay on de-energisation (without auxiliary supply) > s () / inst. () / inst. () () timed outputs (/) or timed output () and instantaneous output ( inst.). () If the device has been stored, de-energised, for more than a month, it must be energised for about seconds in order to activate it. Subsequently, it only takes second to start the time delay. d If this time is not complied with, the relay remains energised indefinitely. eferences Functions A Ac iming ranges 0.0 s 00 h 0 ranges 0.0 s 00 h 0 ranges 0.0 s 00 h 0 ranges 0.0 s 0 min 7 ranges Voltages c or a V p p p a 0 0 V p p p a or c 8 V p p p c or a 0 V p eferences E7 PB E7 MB symmetrical E7 B low level contact Weight (kg) Dimensions and connection schemes Dimensions ail mounting 80 Screw fixing E7 BMW 89, 8, Ø haracteristics : pages 8 and 9 pages and

10 Function D Function Di Function H Symmetrical flashing, start with output in rest position Symmetrical flashing, start with output in operating position iming on energisation / / / inst. () inst. () inst. () Function Qg Function Qt Function W Star-delta timing Star-delta timing On-delay after opening of control contact 0 ms 0 ms / inst. () () timed outputs (/) or timed output () and instantaneous output ( inst.) H W D Qt Qg A,, H, W, D, Di, Qg, Qt 0.0 s 00 h 0 ranges 0.0 s 00 h 0 ranges 0.0 s 00 h 0 ranges 0.0 s 00 h 0 ranges 0.0 s 00 h 0 ranges 0.0 s 00 h 0 ranges p p p p p p p p p p p p p p p p p p p E7 PPB E7 PDB E7 PB E7 YB E7 YB E7 MYB E7 MYMW onnection schemes E7 PB E7 BMW E7 YA E7 B, E7 MB E7 PDB B Z () B B B 8 () 8 () () 8 () () Z 8 Z 8 Z 8 E7 Y E7 MYB E7 MYMW 7 B B Y 7 B Z () Y Z () X B B Z 8 B 8 8 () 8 () 8 () 8 () () Z 8 B B B B Z 8 8 () 8 () () 8 () () Z 8 B Y () B B B 8 () 8 () () 8 () () Z 8 E7 PPB E7 PB B Z () B B B 8 () 8 () () 8 () () Z 8 haracteristics : pages 8 and 9 Dimensions : page pages and

11 Schemes Zelio ime - timing relays relay output, width. mm ecommended application schemes E7, M, P,, P, M, MY Start on energisation E7 M, MA, MV, M,, PM, PD, M, MY Start by external control E7 M, PM, M, MY External control of partial stop E7 MA, MV, A, M Start by external control () () () B B () () () B B Y Z () () () B B X Z () () () B B X Z E7 B Start on de-energisation E7 A Start by external control Y B Y B Y E7 PP Start on energisation E7 PE Start on energisation E7 V Selection of starting phase () () () B B () () B B B () () () B B X Z () E7 M, P, MA, A, M, PP, PM, M, MY onnection of potentiometer E7 MV onnection of potentiometers to asymmetrical timing relays E7 V onnection of potentiometers onnection precautions Z Z Z Z () () Z Z Z (7) (8) Z Supply X or Y or Z Z No galvanic isolation between supply terminals,, B, B and control inputs X, Y, Z, Z. () a 0 0 V except E7 MYMW : z 0 V () z 8 V () z V () Adjustment of the On-delay period () Adjustment of the Off-delay period () Start during the On-delay period : X, Z linked. Start during the Off-delay period : X, Z not linked (7) Off-delay adjustment (tr) (contact / closed) (8) On-delay adjustment (ta) (contact /8 closed) haracteristics : pages 8 and 9 eferences : pages 0 to

12 Schemes (continued) Zelio ime - timing relays relay output, width. mm ecommended application schemes (continued) Power scheme E7 YB ontrol schemes Star-delta function with double On-delay timing Qt F F 9 erminal block B B F W V M V W S S 9 8 Y N B B Z 8 = relay E7 YA Power scheme E7 YB ontrol schemes Star-delta function with contact for switching to star connection Q F W V V M W No galvanic isolation between supply terminals,, B, B and supply terminal Z. his terminal must therefore never be used (factory setting). ontrol of several relays with a single external control contact onnection of a elemecanique -wire NPN or PNP sensor F F S S Y 8 7 N B B erminal block B B 8 8 Z 8 = relay E7 Y Supply,B or B Y or X Z,B or B Y or X Z,B or B Y or X Z Supply,B or B Y or X Z BN B B NPN PNP It is advisable to follow the recommended wiring schemes detailed above and on previous pages. However, the connections below are possible if the restrictions given are taken into account. onnection of an external control contact without using terminal Z: onnection of a elemecanique -wire NPN or PNP sensor without using terminal Z: - possible on all E7 relays with external control option except E7 B, - d.c. supply only. - only possible on relay E7ppppB, - d.c. supply only.,b or B Y or X Z,B or B Y or X Z or 8 V BB Y Z BN B B NPN or 8 V BB Y Z BN B B PNP haracteristics : pages 8 and 9 eferences : pages 0 to

Impedance relay and protection assemblies

Impedance relay and protection assemblies RXZK 21H, 22H, 23H 509 006-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE970175) (SE970184) Features Micro-processor based impedance relay with R and X settings

More information

To order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle

To order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle otor protection relays - T - FWIT Since % of -phase motor failures are due to load problems or loss of phase, the CROUZET range of motor protection relays is indispensable! models give motor protection

More information

American Zettler AZ742 RELAY Datasheet

American Zettler AZ742 RELAY Datasheet American Zettler AZ74 RELAY Datasheet http://www.manuallib.com/american-zettler/az74-relay-datasheet.html FEATURES Dielectric strength 000 Vrms Low height:.7 mm Epoxy sealed version available 0 Amp switching

More information

TeSys contactors. TeSys D contactors. 690 V on a and c

TeSys contactors. TeSys D contactors. 690 V on a and c Selection guide TeSys D contactors Applications All types of control system Rated operational current le max AC- (Ue y 0 V) A A A A A A le AC- (q y 0 C) 0/ A / A /0 A 0 A Rated operational voltage 0 V

More information

TeSys circuit-breakers

TeSys circuit-breakers Presentation Thermal-magnetic motor circuit-breakers types GV2, GV and GV7 GV2-ME, GV2-P, GV-ME and GV7-R motor circuit-breakers are -pole thermal-magnetic circuit-breakers specifically designed for the

More information

DIN Timers TD. Options and ordering codes. Specification

DIN Timers TD. Options and ordering codes. Specification DIN imers D 17.5mm or 22.5mm DIN rail mounting Electronic imers Wide coil operation, 24V to 320V AC/DC Multi ime range / Multi function ON-Delay, OFF-Delay, Asymetrical, Star/Delta versions Perfect to

More information

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows: The basic PC software is supplied free with the recorder. There is an additional charge for the extensive Data Acquisition Software supplied with communication of RS-232/422/485 or Ethernet. The Ordering

More information

Sealing possibility Electrical endurance (ops) Mechanical endurance (ops) Overvoltage category Standards

Sealing possibility Electrical endurance (ops) Mechanical endurance (ops) Overvoltage category Standards Miniature circuit breaker ETIMAT 7,7 0.5 Rated voltage Rated current Rated frequency Rated short-circuit capacity Energy limiting class characteristic Build-in width Mounting on the rail 0/00 V AC, max.

More information

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -A - Introduction - Thank for your purchasing MITSUBISHI ELECTRIC MELPRO TM D Series Digital Protection

More information

7S SERIES. Relay module with forcibly guided contacts 6 A 7S S /0310 7S

7S SERIES. Relay module with forcibly guided contacts 6 A 7S S /0310 7S Relay module with forcibly guided contacts.12 with 2 pole (1NO + 1 N).14 with 4 pole (2 NO + 2 N and 3 NO + 1 N).16 with 6 pole (4 NO + 2 N) For safety applications, with class A forcibly guided contact

More information

PHOENIX CONTACT - 04/2016. Features

PHOENIX CONTACT - 04/2016. Features Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.

More information

Film Capacitors. EMI suppression capacitors. Date: June 2018

Film Capacitors. EMI suppression capacitors. Date: June 2018 Film Capacitors EMI suppression capacitors Date: June 2018 EPCOS AG 2018. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without

More information

Multi-function, economical instrument with 4 functions in the same casing. Accessibility and safety: large-dimension terminals Insulated circuits

Multi-function, economical instrument with 4 functions in the same casing. Accessibility and safety: large-dimension terminals Insulated circuits 200 > Measurement and instrumentation Programmable digital transducers TRIAD 2 range Programmable digital transducers with to 4 analogue outputs Programmable accuracy class PRODUCT ADVANTAGES Up to 4 PROGRAMMABLE

More information

Thermal-Magnetic Circuit Breaker 2210-T2...

Thermal-Magnetic Circuit Breaker 2210-T2... Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring

More information

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011 SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer HO-NSM series I PN = 8, 15, 25 A Ref: HO 8-NSM, HO 15-NSM, HO 25-NSM For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer HO-NP/SP33 series I PN = 8, 15, 25 A Ref: HO 8-NP/SP33, HO 15-NP/SP33, HO 25-NP/SP33 For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the

More information

Number of poles 1-pole 2-pole Minimum Enclosure Contact G2R-1A-E G2R-1-E

Number of poles 1-pole 2-pole Minimum Enclosure Contact G2R-1A-E G2R-1-E The Best Seller eneral purpose power elays of single-pole0 A and double-pole A. Safety-oriented design with dielectric strength of,000 V between coil and contacts, and surge resistance of 0,000 V. and

More information

Pressure transmitters for industrial applications MBS 32 and MBS 33

Pressure transmitters for industrial applications MBS 32 and MBS 33 Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer

More information

Installation Contactors ISU-xxx ISM-xxx

Installation Contactors ISU-xxx ISM-xxx Installation Contactors ISU-xxx ISM-xxx Installation contactors are used in building technology switching cabinets of apartment blocks, office buildings, restaurants and hotels, shopping centres and hospitals

More information

08/072 PKZ2 Motor-Protective Circuit-Breakers Tripping Characteristics

08/072 PKZ2 Motor-Protective Circuit-Breakers Tripping Characteristics 0/07 PKZ Tripping Characteristics Moeller HPL0-00/00 S-PKZ high-capacity contact module, SEA-PKZ contact module Normal switching duty AC-/00V kw A Rated output of three-phase motors 0...0 Hz. 7..... 0.7

More information

TYPE. max. working voltage 250 V 350 V 500 V 750 V. max. overload voltage 500 V 700 V 1000 V 1500 V. basic specifications IEC B

TYPE. max. working voltage 250 V 350 V 500 V 750 V. max. overload voltage 500 V 700 V 1000 V 1500 V. basic specifications IEC B FEATURES Non inductive High pulse loading capability. APPLICATIONS Application for overload and high voltage surge hazard circuits. DESCRIPTION A carbon film is deposited on a high grade ceramic body.

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for

More information

5SJ4...-.HG Circuit Breakers to IEC and UL 489

5SJ4...-.HG Circuit Breakers to IEC and UL 489 Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is

More information

microswitches Low force

microswitches Low force 0/06 Subminiature MICOSWITCHES - PEMIUM V - 870 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed atings from ma Vc up to (6) A

More information

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2... Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed

More information

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available

More information

FAZ tripping characteristics at 30 C: B, C, D to IEC/EN FAZ tripping characteristics at 30 C: R to IEC/EN

FAZ tripping characteristics at 30 C: B, C, D to IEC/EN FAZ tripping characteristics at 30 C: R to IEC/EN FAZ, AZ High-Capacity Tripping Characteristics Moeller HPL011-001/00 1/07 FAZ tripping characteristics at 0 C: B, C, D to IEC/EN 0 9 FAZ tripping characteristics at 0 C: R to IEC/EN 0 97 t [s] 700 00 100

More information

E8EB-N0C2B E8EB-N0B2B

E8EB-N0C2B E8EB-N0B2B Slim Sensor CSM DS_E 1 Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T... Magnetic and Hydraulic-Magnetic Circuit Breaker 830-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of

More information

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en T20WN Torque transducers Data Sheet Special features - Nominal (rated) torques 0.1 N m, 0.2 N m, 0. N m, 1 N m, 2 N m, N m, 10 N m, 20 N m, 0 N m, 100 N m, 200 N m - Accuracy class: 0.2 - Contactless transmission

More information

MCB NB1-63H Miniature Circuit Breaker

MCB NB1-63H Miniature Circuit Breaker NB-H Miniature Circuit Breaker. General. Function protection of circuits against short-circuit currents, protection of circuits against overload currents, switch, isolation, NB-H circuit-breakers are used

More information

BMXART0814 analog input module M340-8 inputs - temperature

BMXART0814 analog input module M340-8 inputs - temperature Product data sheet Characteristics BMXART0814 analog input module M340-8 inputs - temperature Main Range of product Product or component type Electrical connection Input output isolation Input level Analogue

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer LDSR 0.3-TP/SP1 I P R N = 300 ma For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Closed

More information

SUBMINIATURE MICROSWITCHES - PREMIUM

SUBMINIATURE MICROSWITCHES - PREMIUM 0/08 SUBMINIATUE MICOSWITCHES - PEMIUM V - 870 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed atings from ma Vc up to (6) A 0

More information

Non-Contact Safety Systems CMS

Non-Contact Safety Systems CMS Selection table for non-contact safety system // Evaluation units Connection Desi Read head contact assembly Assured switch-on distance S ao [mm] Assured switch-on distance S ar [mm] Number of outputs

More information

Type Function Output config. Auxiliary Case Page

Type Function Output config. Auxiliary Case Page Transducers CONTENTS Page Transducer Survey....4 General description and technical data...8 Transducers DU for AC voltage....12 Transducers DI for AC current....16 Transducers DUD for DC voltage and DID

More information

W250: Compact photoelectric switch series for a broad range of applications

W250: Compact photoelectric switch series for a broad range of applications W0 Photoelectric switches Photoelectric proximity switches, BGS Photoelectric reflex switches Through-beam photoelectric switches W0: Compact photoelectric switch series for a broad range of applications

More information

MODEL: R7K4FML3. Remote I/O R7K4F Series. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.)

MODEL: R7K4FML3. Remote I/O R7K4F Series. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.) Remote I/O R7KF Series I/O MODULE (-III) POWER INPUT DC power R: V DC (Operational voltage range: ±0 %; ripple 0 %p-p max.) 0 (8.7). (.) 7(.8) mm (inch) [] OPTIONS (multiple selections) Output data read

More information

Digital Current Transducer HO-SW series I P N = A. Ref: HO 100-SW; HO 150-SW; HO 200-SW; HO 250-SW

Digital Current Transducer HO-SW series I P N = A. Ref: HO 100-SW; HO 150-SW; HO 200-SW; HO 250-SW Digital Current Transducer HO-SW series I P N = 100... 250 A Ref: HO 100-SW; HO 150-SW; HO 200-SW; HO 250-SW Bitstream output from on onboard Sigma Delta modulator. For the electronic measurement of current:

More information

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08 AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08 Introduction The HAH1BVW family is for the electronic measurement of DC, AC or pulsed currents in high power and low voltage automotive applications

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer HO-NP series I P N = 4, 6, 12, 15 A Ref: HO 4-NP, HO 6-NP, HO 12-NP, HO 15-NP For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary

More information

Softstarter range type PSD & PSDH

Softstarter range type PSD & PSDH Softstarter range type SD & SDH Description Softstarters type S D and S DH ABB s solid state starter range is used when it is important to have a smooth start-up of various types of motor drives. Instead

More information

FEATURES APPLICATIONS DESCRIPTION QUICK REFERENCE DATA. PILKOR components

FEATURES APPLICATIONS DESCRIPTION QUICK REFERENCE DATA. PILKOR components FEATURES Excellent anti-surge characteristics Stable characteristics to moisture resistance even in high resistance range. Good replacement for ceramic plate resistors. APPLICATIONS Telecommunication Industrial

More information

Operating Instructions for Digital Manometer. Model: MAN-SD

Operating Instructions for Digital Manometer. Model: MAN-SD Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5

More information

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up

More information

Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000,

Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000, Digital Current Transducer HLSR-PW series I P N = 16... 50 A Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000, Bitstream output from on onboard Sigma Delta modulator. For the electronic measurement

More information

W 30 Photoelectric proximity switches: Clear signals even with low remission

W 30 Photoelectric proximity switches: Clear signals even with low remission W 0 Photoelectric proximity switches Photoelectric proximity switches, BGS Photoelectric proximity switches, energetic W 0 Photoelectric proximity switches: Clear signals even with low remission In addition,

More information

High-ohmic/high-voltage resistors

High-ohmic/high-voltage resistors FEATURES These resistors meet the safety requirements of: UL1676 (range 510 kω to 11 MΩ) EN60065 BS60065 (U.K.) NFC 92-130 (France) VDE 0860 (Germany) High pulse loading capability Small size. APPLICATIONS

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output

More information

DC/DC regulator Input V Output up to 16 A

DC/DC regulator Input V Output up to 16 A PMC 4000 series Contents Product Program...................... 2 Mechanical Data...................... 3 Connections......................... 3 Absolute Maximum Ratings............. 4 Input...............................

More information

CNY64/ CNY65/ CNY66. Optocoupler with Phototransistor Output. Vishay Telefunken. Description. Applications. VDE Standards

CNY64/ CNY65/ CNY66. Optocoupler with Phototransistor Output. Vishay Telefunken. Description. Applications. VDE Standards Optocoupler with Phototransistor Output Description The CNY64/ CNY65/ CNY66 consist of a phototransistor optically coupled to a gallium arsenide infrared-emitting diode in a 4-lead plastic package. The

More information

Analogue Meters CQ2x07 series

Analogue Meters CQ2x07 series Analogue Meters CQ2x07 series Analogue Power Meters Active, reactive, apparent power meters and Power factor meters with exchangeable scales EQ0207/2207/0107/2107 & YQ0207/2207/0107/2107 o Measurement

More information

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC EM STARK CLE STARK-CLE EM STARK-CLE EM-SO Ø315

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC EM STARK CLE STARK-CLE EM STARK-CLE EM-SO Ø315 D Product description Ideal for ceiling-mounted and wallmounted luminaires Based on annular and compact fluorescent lamps Efficiency of the module up to 127 lm/w SO version is compatible with SWITCH Sensor

More information

General characteristics, Products

General characteristics, Products The Feature Packed line of Manual Motor Protectors Eaton s new XT family of Manual Motor Protectors (MMPs) features a pushbutton or rotary ON/OFF manual disconnect, Class adjustable bimetallic overload

More information

XM1 Motor Protection Relay. Manual XM1 (Revision B)

XM1 Motor Protection Relay. Manual XM1 (Revision B) XM1 Motor Protection Relay Manual XM1 (Revision B) Woodward Manual XM1 GB Woodward Kempen GmbH reserves the right to update any portion of this publication at any time. Information provided by Woodward

More information

High Ohmic/High Voltage Resistors

High Ohmic/High Voltage Resistors High Ohmic/High Voltage Resistors VR68 A metal glazed film is deposited on a high grade ceramic body. After a helical groove has been cut in the resistive layer, tinned electrolytic copper wires are welded

More information

CNY17 Series. Optocoupler with Phototransistor Output. Vishay Telefunken. Description. Applications. VDE Standards.

CNY17 Series. Optocoupler with Phototransistor Output. Vishay Telefunken. Description. Applications. VDE Standards. Optocoupler with Phototransistor Output Description The CNY7 series consists of a phototransistor optically coupled to a gallium arsenide infrared-emitting diode in a 6-lead plastic dual inline package.

More information

5730A High Performance Multifunction Calibrator. Extended specifications

5730A High Performance Multifunction Calibrator. Extended specifications 730A High Performance Multifunction Calibrator Extended specifications General Specifications Warm-Up Time... Twice the time since last warmed up, to a maximum of 30 minutes. System Installation... Rack

More information

W 34: Sensor technology that does justice to demanding requirements

W 34: Sensor technology that does justice to demanding requirements KD0_W_en.qxd.0.00 : Uhr Seite W Photoelectric switches Photoelectric proximity switches BGS Photoelectric reflex switches Through-beam photoelectric switches W : Sensor technology that does justice to

More information

Issued August DATA SHEET. 3VT5 MCCB up to 1600 A

Issued August DATA SHEET. 3VT5 MCCB up to 1600 A ssued August 9 DATA SHEET VT5 MCCB up to 0 A Based on Siemens Catalog V 8 Standard circuit breakers Releases Technical specifications Specifications VT5 circuit breakers Switch disconnectors Type Standards

More information

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008 LV HRC fuse links Overview LV HRC fuses are used for installation systems in non-residential, commercial and industrial buildings as well as in switchboards of power supply companies. They therefore protect

More information

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO. DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link

More information

WT 27 L-2 Laser Photoelectric proximity switches, background suppression -- DC. Dimensional drawing Adjustments possible WT 27L-2F 430

WT 27 L-2 Laser Photoelectric proximity switches, background suppression -- DC. Dimensional drawing Adjustments possible WT 27L-2F 430 WT L- Laser Photoelectric proximity switches, background suppression -- DC 00...00 mm Photoelectric proximity switches Dimensional drawing.. Laser LED, red light Adjustable background suppression 0 0.

More information

3VT4 Molded Case Circuit Breakers up to 1000 A

3VT4 Molded Case Circuit Breakers up to 1000 A VT4 Molded Case Circuit Breakers up to 00 A Catalog Technical nformation VT4 Molded Case Circuit Breakers up to 00 A General data / - Overview Circuit breakers Switch disconnectors / - Selection and ordering

More information

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop TECHNICA DATASHEET D-P--C Rope Safety Switches with reset for emergency stop Metal or polymer housing, from one or three conduit entries Protection degree IP6 In conformity with EN ISO 13850 contact blocks

More information

Issued August DATA SHEET. 3VT3 MCCB up to 630 A

Issued August DATA SHEET. 3VT3 MCCB up to 630 A ssued August 9 DATA SHEET VT MCCB up to 6 A Based on Siemens Catalog V 6 8 Circuit breakers Switch disconnectors Technical specifications Specifications Type VT 76-AA6/6/56-AA, VT 76-AA6/6/56-AA Circuit

More information

90 MCB MODULAR CIRCUIT BREAKERS FOR CIRCUIT PROTECTION

90 MCB MODULAR CIRCUIT BREAKERS FOR CIRCUIT PROTECTION MCB - MTC - MT - MTHP Technical data TYPE MTC MT MTC45 MTC60 MTC100 MT 45 MT 60 Rated current (In) (A) 2-32 6-32 6-32 6-40 1-63 Utilization category A A A A A Rated operational voltage (Ue) (V) 230/400-240/415

More information

XD1-L Cable Differential Protection Relay

XD1-L Cable Differential Protection Relay XD1-L Cable Differential Protection Relay Manual XD1-L (Revision B) Woodward Manual XD1-L GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information

More information

X T O B P 1 6 B C 1 S

X T O B P 1 6 B C 1 S 9 Overload Relays XTOB, XTOT May 07 Contents Description Page Overload Relays XTOB, XTOT Selection................ 9 Product Selection.......... 95 Accessories............... 9 Technical Data and Specifications............

More information

Zelio Relay - Solid State Relays

Zelio Relay - Solid State Relays Selection guide SSR solid state relays Applications Panel mounted PF00--Q Contact type N/O SPST contact Control voltage ranges a 0 0 V c V Operating voltages a 0 V, 0 V, 0 V Type of switching a Zero voltage

More information

Single Phase Motors Technical Datasheets

Single Phase Motors Technical Datasheets Single Phase Motors Technical Datasheets EN A dynamic, strong and ambitious Group: Orange1 Holding is an international renown Group, one of the most important European manufacturers of single-phase and

More information

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS SUMMARY OF MODELS OF HRC FUSE-LINKS Type PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size

More information

TeSys enclosed starters 2

TeSys enclosed starters 2 Characteristics, references TeSys enclosed starters D..L. starters for motor control 0. to. kw with -phase thermal overload relay with protected phases Characteristics () Conforming to standards IEC 0--,

More information

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation S95.U0 / S95.U Head mounted temperature transmitters, programmable, Pt 00 (RTD), thermocouples, electrical isolation Resistance thermometer (,, wire circuit) Thermocouples Resistance remote signalling

More information

Online data sheet WL280-S230 W280 COMPACT PHOTOELECTRIC SENSORS

Online data sheet WL280-S230 W280 COMPACT PHOTOELECTRIC SENSORS Online data sheet WL80-S30 W80 WL80-S30 W80 A B C D E F Illustration may differ Ordering information Type Part no. WL80-S30 607484 Included in delivery: P0 (), BEF-W80 () Other models and accessories www.sick.com/w80

More information

E6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders

E6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders Multi-turn High-precision Encoder Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders Reset function for easy origin alignment when built-into equipment. Multi-turn

More information

LED light engine / OLED LED compact. Uengine DLE G2 integrated ADV

LED light engine / OLED LED compact. Uengine DLE G2 integrated ADV Uengine DLE G2 integrated ADV uengine DLE Product description Module with integrated electronics For downlights Light engine operating with 23 V AC Luminous flux range from 1,24 2,43 lm High system efficacy

More information

Absolute encoders multiturn

Absolute encoders multiturn elektronischer electronic multiturn, Multiturn, magnetic magnetisch Sendix M66 / M68 (shaft / hollow shaft) The Sendix M6 with Energy Harvesting Technology is an electronic multiturn encoder in miniature

More information

DATA SHEET: TEMPOWER2 ACB

DATA SHEET: TEMPOWER2 ACB Electrical haracteristics to IE 097, IE 097 Type Series AMERE RATING(A) AR0SB Standard RATED URRENT (max) [I n ](A) JIS,IE, EN, AS NEMA, ANSI Marine NEUTRAL OLE AMERES FRAME (A) NUMBER OF OLES 3 RATED

More information

PHASED OUT. FL ballasts Electronic dimming. PCA TC BASIC Y II, W BASIC compact

PHASED OUT. FL ballasts Electronic dimming. PCA TC BASIC Y II, W BASIC compact EL Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A BAT Noise-free precise control via DSI signal, switchdim or corridorfunction Nominal life

More information

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar

More information

Universal limit switches

Universal limit switches SWITCHES.CROUZET.COM 1 LIMIT SWITCHES 0/016 Universal limit switches 8384 standard 8384 with positive break operation Conformity to standards IEC / EN 60947--1, including Annex K for version with positive

More information

BMXART0814 analog input module M340-8 inputs - temperature

BMXART0814 analog input module M340-8 inputs - temperature Product data sheet Characteristics BMXART0814 analog input module M340-8 inputs - temperature Product availability : Stock - Normally stocked in distribution facility Price* : 1485.00 USD Main Range of

More information

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels TF 0 / TF 0-Ex Field mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.69 EN USA Input Resistance thermometer (,, wire circuit) Thermocouples

More information

I Ex d/e Switch- and Control-Equipment I

I Ex d/e Switch- and Control-Equipment I I Ex d/e Switch- and Control-Equipment I Customised enclosure, covered by Type Examination Certificates, can be individually combined from CEAG s numerous built-in components. Furthermore control units

More information

Capacitive Sensors. Contents

Capacitive Sensors. Contents Contents Capacitive sensors detect the change in capacitance caused by the approach of an object. Their advantage lies in the ability to detect virtually any material, from metals to oils. 4.2 Definitions,

More information

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -C - Safety section - This Safety section should be read before starting any work on the relay.

More information

Pressure. 1 Fitting PA R - N R2

Pressure. 1 Fitting PA R - N R2 INTERNAL STRUCTURE (R 1/4) 4 1 2 3 FEATURES High corrosion resistance and drip-proof construction port attachment made of Proven IP-65 grade gauge body (IP-65 in accordance with IEC) Standard product provides

More information

W 9 L: Laser photoelectric switches: small, light and reliable

W 9 L: Laser photoelectric switches: small, light and reliable W 9 Laser photoelectric switches Photoelectric proximity switches, BGS Photoelectric reflex switches Through-beam photoelectric switches W 9 L: Laser photoelectric switches: small, light and reliable The

More information

Digital display Pressure range ON/OFF output Linear output Model No Positive pressure 0 to 98 kpa (0 to 1 kgf/cm 2 ) NPN open collector o 1 to o5

Digital display Pressure range ON/OFF output Linear output Model No Positive pressure 0 to 98 kpa (0 to 1 kgf/cm 2 ) NPN open collector o 1 to o5 Pressure Sensor E8CC with Built-in Microcomputer and Digital Display and New E8CB General-purpose Model Withstands a of 490 kpa (5 kgf/cm 2 ) and highly reliable. Incorporates a two-turn adjuster ensuring

More information

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet: abc instruments international FLT5A Thermometer Land Instruments International Dronfield, S18 1DJ England Telephone: (1246) 417691 Facsimile: (1246) 41585 Email: infrared.sales@landinst.com Internet: www.landinst.com

More information

Dual 4-Input AND Gate

Dual 4-Input AND Gate TENIAL DATA Dual 4-Input AND ate The is high-speed Si-gate MOS device and is pin compatible with low power Schottky TTL (LSTTL). The device provide the Dual 4-input AND function. Outputs Directly Interface

More information

90 MCB range Modular circuit breakers for circuit protection

90 MCB range Modular circuit breakers for circuit protection MCB - MTC - MT - MTHP Technical data TYPE MTC MT MTC45 MTC60 MTC100 MT 45 MT 60 Rated current (In) (A) 2-32 6-32 6-32 6-40 1-63 Utilization category A A A A A Rated operational voltage (Ue) (V) 230 / 400

More information

Miniatur Circuite Breakers (MCB)

Miniatur Circuite Breakers (MCB) Redline Miniatur Circuite Breakers (MCB) Technical data MCB s Series Standards Tripping characteristics Nominal current Calibration temperature Number of poles (#mod) Neutral pole protected Nominal voltage

More information

Z7A. Load cells. Special features. Data sheet. Wiring code

Z7A. Load cells. Special features. Data sheet. Wiring code Z7A Load cells Special features - Complies with OIML R60 regulations up to 3000 d - Max. capacities: 500 kg... 10 t - Fulfills EMC requirements in accordance to EN 45 501 - Low transducer height - Robust

More information

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 15mm 2000lm 8x0 H ADV D50

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 15mm 2000lm 8x0 H ADV D50 w LED light engine / OLED Product description For spotlights and downlights Housing with Snap-On feature for easy reflector mounting Luminous flux up to 2,92 lm at tp = 65 C High efficacy up to 147 lm/w

More information

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 15mm 2000lm 9x0 H EXC D50

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 15mm 2000lm 9x0 H EXC D50 w LED light engine / OLED Product description For spotlights and downlights Housing with Snap-On feature for easy reflector mounting Luminous flux up to 2,51 lm at tp = 65 C High efficacy up to 124 lm/w

More information