Sensors for pressure control OsiSense XMLR
|
|
- Clemence Jacobs
- 5 years ago
- Views:
Transcription
1 Sensors for pressure control LR Catalogue Simply easy! TM
2
3 Contents Sensors for pressure control LR General presentation pages 00/ and 00/ Presentation page 00/ Description page 00/ Functions page 00/ s - to 0 bar / -. to 0 psi page 00/ 0 to bar / 0 to. psi page 00/ 0 to. bar / 0 to. psi page 00/ 0 to 0 bar / 0 to psi page 00/ 0 to bar / 0 to psi page 00/ 0 to bar / 0 to psi page 00/ 0 to 0 bar / 0 to 0 psi page 00/ 0 to 00 bar / 0 to 0 psi page 00/ 0 to 0 bar / 0 to 0 psi page 00/ 0 to 0 bar / 0 to psi page 00/ 0 to 00 bar / 0 to 00 psi page 00/ 0 to 00 bar / 0 to 00 psi page 00/ Accessories page 00/ 0 S-EN version:.0
4 General presentation Pressure sensors with -digit display, XMLR LR Pressure sensors are used to control and measure pressure or vacuum levels in hydraulic or pneumatic systems. They transform the pressure into an electrical signal. They then produce an analogue output which is proportional to the measured pressure and/or one or two switching outputs for which the switching point can be adjusted. The high precision and performance of LR pressure sensors makes them suitable for numerous industrial applications requiring pressure/vacuum display, control or regulation. Easy to mount Minimize installation time and effort. Mounting is easy and fl exible with the compactsized, rotating body and reversed display function. With its compact size, the LR pressure sensor is easily integrated in the machine. Compact size > With a height of just to 00 mm depending on the pressure range and the fl uid entry, LR is one of the most compact pressure switches on the market. mm...00 mm mm Rotating body > The body of the LR pressure sensor can be rotated 00, thus enabling the front face of the product to be orientated as required following connection to the pressure inlet pipe. The easy swith for machine pressure control 00-EN version:.
5 bar psi kpa MPa OUT OUT bar psi kpa MPa OUT OUT General presentation (continued) Pressure sensors with -digit display, XMLR Easy to mount (continued) Display inversion function > The display can be inverted vertically to adapt to the sensor s installation position. Easy to set up RUN Menu naming and structure based on VDMA* standards > The ergonomic design of LR sets a new standard for ease of confi guration. SP rp % % 00% NP % NP Navigation using just two pushbuttons > Two simple pushbuttons are all that is needed to navigate through an intuitive menu structured according to VDMA standards. SP % 00% NP rp % % NP EF (extended functions) res ds 0 0s dr 0 0s Pushbutton to display a value or parameter or to save a selected value or parameter and return to the menu. Pushbutton to scroll from one menu to another or to increase a value or change a parameter Menu structure based on VDMA standards Easy to maintain At each device start up, all segments of the display light up briefl y to confi rm that it is operating correctly. The device can be tested using a diagnostic function which checks the whole electronic signal processing chain. This function is accessible via the Dia menu. It can be activated directly by the PLC by remote control via the test input (on products which only have one analogue output). LR pressure sensors also include a recording of the high and low pressure values measured since the last reset. These values can be displayed via the Hi and Lo menus. * VDMA: Verband Deutscher Maschinen und Anlagenbau e. V. 00-EN version:.
6 bar psi kpa MPa OUT OUT bar psi kpa MPa OUT OUT Presentation, description, functions Pressure sensors with -digit display, XMLR Compact plastic body, stainless steel L fl uid entry With analogue and solid-state outputs Presentation XMLR are used for pressure control of hydraulic oils, fresh water, air and refrigerant fl uids, between - and 00 bar. Depending on the model, XMLR sensors are available with different configurations in order to meet the highest number of requirements: b one analogue output, -0 ma or 0-0 V, proportional to the measuring range, b one analogue output and one switching output, PNP or NPN, b two switching outputs, b one analogue output and two switching outputs. Compact and robust: The stainless steel L fl uid entry and glass-fi ber-reinforced polyarylamide body provide the XMLR pressure sensors with excellent mechanical resistance, improved corrosion resistance and an P/IP degree of protection. These products are for a nominal supply voltage of V c and have a to V c operating range. They are particularly suitable for: b Moulding and thermoforming presses b Injection machines b Pneumatic systems and assembly machinery b Hydraulic systems of lifting and handling equipment b Pumping and fresh water treatment Compact mm to 00 mm overall, depending on model. Reversed display function Simplicity of setting-up The body of the LR pressure sensor can be turned through 00, thus enabling the front face of the product to be orientated as required following connection to the pressure inlet pipe. In addition, the reversed display function simplifi es reading in the event of upside down mounting (fl uid entry from above). Description M male connector, or -pin depending on model. -digit, segment display and LED indicator for pressure unit and output state. Navigation keys for setting and configuring the menus (conforming to VDMA ). Fluid entry: G / female, /"-NPT female or /-0UNF female, depending on model. Functions Configurable functions For the display: b Pressure unit of measurement (bar, psi, kpa or MPa). b Display refresh time: fast (0 ms), normal (00 ms), slow (00 ms). b 0 reversed display function. For the analogue output ( 0 ma or 0 0 V): b Offset compensation in the range of ±% of the nominal pressure. b Adjustment of analogue end point between and % of the nominal pressure. For each solid-state output: b NO or NC contact b Switching mode of outputs: Hysteresis (pumping) or Window (control). b Time delay both on trip and on reset (adjustable from 0 to 0 s, in steps of s). 0 Fast diagnostic functions b Illumination of all the segments of the display on each power-up, enabling checking of their operation. b Diagnostic function for checking correct operation of the sensor. b Saving of min. and max. pressures measured by the sensor and their subsequent display. 00-EN_Ver.0.indd
7 s Pressure sensors with -digit display, XMLR Compact plastic body, stainless steel L fl uid entry With analogue and solid-state outputs XMLRpppGppp XMLRpppGppp - to 0 bar (-. to 0 psi) Maximum permissible accidental pressure: bar, destruction pressure: bar G / female DIN -Y fluid connection 0 ma XMLRM0G0T V c XMLRM0G0T ma x PNP XMLRM0GP ma x NPN XMLRM0GN V c x PNP XMLRM0GP V c x NPN XMLRM0GN 0.0 x PNP XMLRM0GP0 0.0 x NPN XMLRM0GN ma x PNP XMLRM0GP ma x NPN XMLRM0GN ma XMLRM0G0T 0. 0 ma x PNP XMLRM0GP 0. 0 ma x NPN XMLRM0GN 0. x PNP XMLRM0GP0 0. x NPN XMLRM0GN ma x PNP XMLRM0GP 0. 0 ma x NPN XMLRM0GN 0. 0 to bar (0 to. psi) Maximum permissible accidental pressure: bar, destruction pressure: bar G / female DIN -Y fluid connection 0 ma XMLR00G0T V c XMLR00G0T ma x PNP XMLR00GP ma x NPN XMLR00GN V c x PNP XMLR00GP V c x NPN XMLR00GN 0.0 x PNP XMLR00GP0 0.0 x NPN XMLR00GN ma XMLR00G0T V c XMLR00G0T 0. 0 ma x PNP XMLR00GP 0. 0 ma x NPN XMLR00GN 0. x PNP XMLR00GP0 0. x NPN XMLR00GN to. bar (0 to. psi) Maximum permissible accidental pressure: bar, destruction pressure: bar G / female DIN -Y fluid connection 0 ma XMLRDG0T ma XMLRDG0T ma x PNP XMLRDGP ma x NPN XMLRDGN V c x PNP XMLRDGP V c x NPN XMLRDGN 0.0 x PNP XMLRDGP0 0.0 x NPN XMLRDGN ma x PNP XMLRDGP 0. 0 ma x NPN XMLRDGN 0. x PNP XMLRDGP0 0. x NPN XMLRDGN EN_Ver.0.indd
8 s Pressure sensors with -digit display, XMLR Compact plastic body, stainless steel L fl uid entry With analogue and solid-state outputs 0 XMLRpppGppp XMLRpppGppp XMLRpppGppp 0 to 0 bar (0 to psi) Maximum permissible accidental pressure: 0 bar, destruction pressure: 0 bar G / female DIN -Y fluid connection 0 ma XMLR00G0T V XMLR00G0T ma x PNP XMLR00GP ma x NPN XMLR00GN V x PNP XMLR00GP V x NPN XMLR00GN 0.0 x PNP XMLR00GP0 0.0 x NPN XMLR00GN ma x PNP XMLR00GP ma x NPN XMLR00GN ma XMLR00G0T V XMLR00G0T 0. 0 ma x PNP XMLR00GP 0. 0 ma x NPN XMLR00GN V x PNP XMLR00GP V x NPN XMLR00GN 0. x PNP XMLR00GP0 0. x NPN XMLR00GN ma x PNP XMLR00GP 0. 0 ma x NPN XMLR00GN 0. /-0UNF-B female fluid connection x PNP XMLR00GP0 0.0 x NPN XMLR00GN to bar (0 to psi) Maximum permissible accidental pressure: bar, destruction pressure: bar G / female DIN -Y fluid connection 0 ma XMLR0G0T V XMLR0G0T ma x PNP XMLR0GP ma x NPN XMLR0GN V x PNP XMLR0GP 0.0 x PNP XMLR0GP ma XMLR0G0T 0. 0 ma x PNP XMLR0GP 0. 0 ma x NPN XMLR0GN 0. x PNP XMLR0GP0 0. x NPN XMLR0GN to bar (0 to psi) Maximum permissible accidental pressure: 00 bar, destruction pressure: 00 bar G / female DIN -Y fluid connection 0 ma XMLR0G0T ma XMLRDG0T ma x PNP XMLR0GP ma x NPN XMLR0GN V x PNP XMLR0GP V x NPN XMLR0GN 0.0 x PNP XMLR0GP0 0.0 x NPN XMLR0GN ma XMLR0G0T 0. 0 ma x PNP XMLR0GP 0. 0 ma x NPN XMLR0GN 0. x PNP XMLR0GP0 0. x NPN XMLR0GN EN_Ver.0.indd
9 s (continued) Pressure sensors with -digit display, XMLR Compact plastic body, stainless steel L fl uid entry With analogue and solid-state outputs XMLRpppGppp XMLRpppGppp XMLRpppMppp XMLRpppMppp XMLRpppMppp 0 to 0 bar (0 to 0 psi) Maximum permissible accidental pressure: 0 bar, destruction pressure: 0 bar G / female DIN -Y fluid connection 0 ma XMLR00G0T V c XMLR00G0T ma x PNP XMLR00GP ma x NPN XMLR00GN V c x PNP XMLR00GP V c x NPN XMLR00GN 0.0 x PNP XMLR00GP0 0.0 x NPN XMLR00GN ma x PNP XMLR00GP ma x NPN XMLR00GN ma XMLR00G0T 0. 0 ma x PNP XMLR00GP 0. 0 ma x NPN XMLR00GN 0. x PNP XMLR00GP0 0. x NPN XMLR00GN to 00 bar (0 to 0 psi) Maximum permissible accidental pressure: 00 bar, destruction pressure: 00 bar G / female DIN -Y fluid connection 0 ma XMLR00M0T V c XMLR00M0T 0. 0 ma x PNP XMLR00MP 0. 0 ma x NPN XMLR00MN V c x PNP XMLR00MP V c x NPN XMLR00MN 0. x PNP XMLR00MP0 0. x NPN XMLR00MN ma XMLR00M0T 0. 0 ma x PNP XMLR00MP 0. 0 ma x NPN XMLR00MN 0. x PNP XMLR00MP0 0. x NPN XMLR00MN to 0 bar (0 to 0 psi) Maximum permissible accidental pressure: 0 bar, destruction pressure: 0 bar G / female DIN -Y fluid connection 0 ma XMLR0M0T 0. 0 ma XMLR0M0T 0. 0 ma x PNP XMLR0MP 0. 0 ma x NPN XMLR0MN V c x PNP XMLR0MP V c x NPN XMLR0MN 0. x PNP XMLR0MP0 0. x NPN XMLR0MN0 0. x PNP XMLR0MP0 0. x NPN XMLR0MN0 0. /-0UNF-B female fluid connection x PNP XMLR0MP0 0. x NPN XMLR0MN EN_Ver.0.indd
10 s (continued) Pressure sensors with -digit display, XMLR Compact plastic body, stainless steel L fl uid entry With analogue and solid-state outputs 0 XMLRpppMppp XMLRpppMppp XMLRpppMppp 0 to 0 bar (0 to psi) Maximum permissible accidental pressure: 0 bar, destruction pressure: 00 bar G / female DIN -Y fluid connection 0 ma XMLR0M0T V c XMLR0M0T 0. 0 ma x PNP XMLR0MP 0. 0 ma x NPN XMLR0MN V c x PNP XMLR0MP V c x NPN XMLR0MN 0. x PNP XMLR0MP0 0. x NPN XMLR0MN ma x PNP XMLR0MP 0. 0 ma x NPN XMLR0MN 0. 0 ma XMLR0M0T 0. 0 ma x PNP XMLR0MP 0. 0 ma x NPN XMLR0MN V c x PNP XMLR0MP 0. x PNP XMLR0MP0 0. x NPN XMLR0MN0 0. /-0UNF-B female fluid connection x PNP XMLR0MP0 0. x NPN XMLR0MN to 00 bar (0 to 00 psi) Maximum permissible accidental pressure: 00 bar, destruction pressure: 00 bar G / female DIN -Y fluid connection 0 ma XMLR00M0T V c XMLR00M0T 0. 0 ma x PNP XMLR00MP 0. 0 ma x NPN XMLR00MN V c x PNP XMLR00MP V x NPN XMLR00MN 0. x PNP XMLR00MP0 0. x NPN XMLR00MN ma x PNP XMLR00MP 0. 0 ma x NPN XMLR00MN 0. 0 ma XMLR00M0T 0. 0 ma x PNP XMLR00MP 0. 0 ma x NPN XMLR00MN 0. x PNP XMLR00MP0 0. x NPN XMLR00MN to 00 bar (0 to 00 psi) Maximum permissible accidental pressure: 00 bar, destruction pressure: 00 bar G / female fluid connection 0 ma XMLR00M0T V XMLR00M0T 0. 0 ma x PNP XMLR00MP V x PNP XMLR00MP 0. x PNP XMLR00MP EN_Ver.0.indd
11 s (continued) Pressure sensors with -digit display, XMLR Accessories XMLZL00 Accessories Description For use with Cooler with G / A (male) fluid connections Usage temperature: 0 C for the fl uid, 0 C for the ambient air XMLRppppppp XMLZL Connectors Description For use with Type M female connector, -pin Metal clamping ring XMLRpppp0Tpp XMLRppppPpp XMLRppppNpp XMLRppppP0p XMLRppppN0p Straight XZCCFDM0B 0.00 Elbowed XZCCFCM0B 0.00 M female connector, -pin Metal clamping ring XMLRppppPp XMLRppppNp Straight XZCCFDM0B 0.00 XZCCFDMp0B Elbowed XZCCFCM0B 0.00 XZCCFCMp0B Pre-wired connectors and jumper cables (PUR cable) Description For use with Type Length of cable m Pre-wired M female connectors, -pin Metal clamping ring XMLRpppp0Tpp XMLRppppppp XMLRppppP0p XMLRppppN0p Straight XZCPL 0.00 XZCPL XZCPL0 0.0 Elbowed XZCPL 0.00 XZCPL XZCPL0 0.0 XZCPLp XZCPLp M-M -pin jumper cables XMLRpppp0Tpp XMLRppppppp XMLRppppP0p XMLRppppN0p Straight female connector Elbowed female connector XZCR0C 0.00 XZCR0C 0.00 XZCR0C 0.00 XZCR0C 0.00 M-M -pin jumper cables XMLRppppPp XMLRppppNp Straight female connector XZCR0D 0.00 XZCR0D 0.00 XZCR0pppp XZCR0pppp Elbowed female connector XZCR0D 0.00 XZCR0D EN_Ver.0.indd
12 Schneider Electric Industries SAS Head Offi ce, rue Joseph Monier F-00 Rueil-Malmaison France The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specifi c user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specifi c application or use thereof. Neither Schneider Electric nor any of its affi liates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Design: Schneider Electric Photos: Schneider Electric
DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.
DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link
More informationBMXART0814 analog input module M340-8 inputs - temperature
Characteristics analog input module M340-8 inputs - temperature Complementary Analog/Digital conversion Analogue input resolution Input impedance Permitted overload on inputs Common mode rejection Differential
More informationED 701 General Industry Pressure Transmitter
ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationOperating instructions Pressure sensor PN / / 2007
Operating instructions Pressure sensor PN42 704298 / 00 0 / 2007 Contents afety instructions... 3 2 Function and features... 4 3 Function... 5 3. witching function... 5 4 Installation... 5 5 Electrical
More informationOperating instructions Vortex flow meter. SVxxx / / 2015
Operating instructions Vortex flow meter SVxxx0 80229859 / 00 06 / 2015 Contents 1 Safety instructions...3 2 Functions and features...3 3 Function...4 4 Installation...4 5 Electrical connection...6 6 Operating
More informationCabling accessories OsiSense XZ
Cabling accessories OsiSense XZ Catalogue Rugghölzli CH - Busslingen Tel. + (0) Fax + (0) 0 Rugghölzli CH - Busslingen Tel. + (0) Fax + (0) 0 Opting for sensors incorporating a connector gives you a quick
More informationPressure Transmitter ED 701
Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation
More informationOperating Instructions for Digital Manometer. Model: MAN-SD
Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5
More informationCabling accessories OsiSense XZ. Catalogue
Cabling accessories OsiSense XZ Catalogue Opting for sensors incorporating a connector gives you a quick and high performance solution In the event of having to replace a sensor on a machine, this is
More informationDS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm
Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar
More informationConductivity sensor for hygienic applications
Conductivity sensor for hygienic applications Type 8221 can be combined with Perfect for demanding applications in the hygienic industry (CIP and SIP compatible) Variants available for usage over a wide
More informationHydraulic Pressure NAH Applications. Features. New generation available - refer to
NAH 8 Hydraulic Pressure Transmitter New generation available - refer to www.trafag.com/h70 Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for
More informationPRODUCT CATALOGUE PREssURE switch
PRODUCT CATALOGUE PREssURE switch w w w. p a a b. c o m Pressure AT THe HIGHesT LeVeL Successful mediumsized companies are not successful because they are active in many areas, but rather because they
More informationPressure transmitters for industrial applications MBS 32 and MBS 33
Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer
More informationRelative pressure transmitter type 520
Relative pressure transmitter type 520 Pressure range The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the pressure measuring cell is fully
More informationOperating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04
Operating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04 UK 80223776 / 00 11 / 2018 Contents 1 Preliminary note...3 2 Safety instructions...4 3 Functions and features...4 4 Function...5
More informationCapacitive Sensors. Contents
Contents Capacitive sensors detect the change in capacitance caused by the approach of an object. Their advantage lies in the ability to detect virtually any material, from metals to oils. 4.2 Definitions,
More informationPhoto-electric sensors1
References Three-wire DC, solid-state output Teach mode - + Sensing distance (Sn) m Depending on Function Output Connection Reference Weight NO/NC Prograable PNP Pre-cabled XUDAPSML 0.00 M XUDAPSMM 0.00
More informationOperating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014
Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM8004 80003223 / 00 05 / 2014 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...4 3 Functions and features...5
More informationBASE. Rotary limit switch. OptiOnS. FEAtuRES. CERtiFiCAtiOnS
Rotary limit switch BASE Rotary limit switch used to control and measure the movement of industrial machines. Its compact size make it suitable for use in narrow spaces. FEAtuRES It consists of a gear
More informationOperating instructions Magnetic-inductive flow meter. SM6x01 SM7x01 SM8x / / 2015
Operating instructions Magnetic-inductive flow meter UK SM6x01 SM7x01 SM8x01 80223585 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...4
More informationDMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm
DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up
More informationW 9 L: Laser photoelectric switches: small, light and reliable
W 9 Laser photoelectric switches Photoelectric proximity switches, BGS Photoelectric reflex switches Through-beam photoelectric switches W 9 L: Laser photoelectric switches: small, light and reliable The
More informationDMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output
More informationø6, ø10, ø15, ø20, ø25, ø32, ø40, ø50, ø63 How to Order Switch rail Nil Standard stroke Refer to page 12 for standard stroke.
Magnetically Coupled Rodless Cylinder: Direct Mount ype Series ø, ø, ø, ø, ø, ø, ø, ø0, ø Direct mount type mm mm mm mm mm mm mm 0 0 mm mm 00 MB Piping type Both sides piping type Centralized piping type
More informationPascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure
DATASHEET Pascal ET Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure - electrical signals (ma, mv, V, ) - temperature (TC and
More informationCompact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm.
Flow sensors www.ifm.com/mid Compact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm. For industrial applications Volumetric flow sensor efector mid. High-precision
More informationE8EB-N0C2B E8EB-N0B2B
Slim Sensor CSM DS_E 1 Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree
More informationRoHS. Versatile. X g. X 2 e
s IN8, - and The inclinometers of the IN8 series allow measuring inclinations in the range of ±85 or -dimensional inclinations up to 0. With their high robustness, their protection level up to max. IP9k
More informationSECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:
SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine
More informationUniversal limit switches
SWITCHES.CROUZET.COM 1 LIMIT SWITCHES 0/016 Universal limit switches 8384 standard 8384 with positive break operation Conformity to standards IEC / EN 60947--1, including Annex K for version with positive
More informationField IT 50T Series Transmitters
Data Sheet SS/G/A_ Field IT 0T Series Transmitters gauge/absolute pressure transmitter Ranges: -00 to 0000kPa - to 00bar -. to 6000psi Base accuracy : 0.% (BFSL) Chemical Vapour Deposition (CVD) technology
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationFLOW SENSOR FOR LIQUID MEDIA Serie 210
FLOW SENSOR FOR LIQUID MEDIA Serie 0 Flow range 0.... 0 l/min Nominal diameters DN 6 / 8 / 0 / / 0 / Temperature measurement -0... + ÀC In comparison to the OEM flow sensor (type 00), the type 0 is available
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationIndustrial Pressure Transmitter
ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter
More informationProximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C
ASH & ALAIN INDIA PVT LTD S-00, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-000(India) Tel : 0-797575 Fax : 0-79757 E-mail : sales@ashalain.com Proximity Ideal for High Temperatures and Cleaning
More informationAir velocity & IAQ measuring instruments
Data sheet dp Air velocity & IAQ measuring instruments - air velocity & IAQ measuring instrument - dp air velocity & IAQ measuring instrument incl. differential pressure C CO Intuitive: clearly structured
More informationSolenoid valves Type EVUL
Data sheet Solenoid valves EVUL EVUL solenoid valves are designed to fit into compact refrigeration systems. Available in servo operated versions they can be applied in liquid, suction, and hot gas lines.
More informationIDENTIFICATION STS400
IDENTIFICATION APPLICATIONS Tracking and Traceability is a primary need of tire manufactures. In logistics, WIP, quality control, and compliance, tires get tracked at every step of production process.
More informationGS4000 DATASHEET JUNHO 2013
GS4000 DATASHEET JUNHO 2013 www.severntrentservices.com Biochem T70GS4000 Chlorine Dioxide Generator - 2g/day - 10g/h System Advantages Dosage Flexibility The generator produces a chlorine dioxide solution,
More informationHYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC
HYGRASGARD AFF - LC AFTF - LC sensors, calibrateable, with and active passive output Quality product for HVAC sector, accuracy % r.h. The calibrateable room humidity and temperature sensor HYGRASGARD KFF
More informationBTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters
FEATURES 5 mbar to 0 bar, 0. to 50 psi differential pressure...6 or...0 ma Precision temperature compensated and calibrated Rugged aluminium housing Female /8" BSP and /8" NPT fittings MEDIA COMPATIBILITY
More informationDS 200 DS 200 DRUCK & TEMPERATUR LEITENBERGER GMBH. Electronic Pressure Switch. Stainless Steel Sensor. Electronic Pressure Switch
DRUCK & TEMPERATUR LEITENBERGER GMBH DS 00 Electronic Pressure Switch Stainless Steel Sensor accuracy according to IEC 00: standard: 0. % FSO option: 0. % FSO Nominal pressure: from 0... 00 mbar up to
More informationOne-hand ph/temperature measuring instrument
One-hand ph/temperature measuring instrument testo 205 ph tip embedded in breakage-proof plastic ph Combined penetration tip with temperature probe Maintenance-free gel electrolyte C Measurement tip exchangeable
More informationall stainless steel transducer multimedia compatibility
all stainless steel transducer multimedia compatibility High-Performance Silicon technology LARGE INVENTORY Fast Shipment! 0-0.07 to 0-690 bar 100 mv, 0 to 5 V, and 4 to 20 ma Outputs U 1, 2 & 5 psi Low
More informationFlow sensor for liquid media type 210
Flow sensor for liquid media type 0 Flow range 0.... 0 l/min Nominal diameters DN 6 / 8 / 0 / / 0 / Temperature measurement -0... + ÀC In comparison to the OEM flow sensor (type 00), the type 0 is available
More informationW250: Compact photoelectric switch series for a broad range of applications
W0 Photoelectric switches Photoelectric proximity switches, BGS Photoelectric reflex switches Through-beam photoelectric switches W0: Compact photoelectric switch series for a broad range of applications
More informationVK2 volume flow controller Overview
New option with sound attenuator Maintenance-free VK2 volume flow controller that operates without an auxiliary power supply, for ventilation and air conditioning systems. Adjustable on site. Outstanding
More informationD5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder
with incremental encoder Draw wire encoder A40 Traverse speed max. 0.8 m/s The draw wire system A40 with incremental encoder excels with its compact construction. RoHS Compact and simple Measuring length
More informationPressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27
Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for
More informationOperating instructions Magnetic-inductive flow meter SM4x00 SM6x00 SM7x00 SM8x00 SM6x01 SM7x01 SM8x01
Operating instructions Magnetic-inductive flow meter SM4x00 SM6x00 SM7x00 SM8x00 SM6x01 SM7x01 SM8x01 UK 80224865 / 00 02 / 2018 Contents 1 Preliminary note...4 2 Safety instructions...4 3 Functions and
More informationcompact ejector, Series ECS with release valve with silencer with non-return valve, With filter vacuum switch: electronic 1x PNP and 1x analog
with release valve with silencer with non-return valve, With filter vacuum switch: electronic x PNP and x analog Ambient temperature min./max. +0 C / +0 C Medium temperature min./max. +0 C / + C Working
More informationDigital display Pressure range ON/OFF output Linear output Model No Positive pressure 0 to 98 kpa (0 to 1 kgf/cm 2 ) NPN open collector o 1 to o5
Pressure Sensor E8CC with Built-in Microcomputer and Digital Display and New E8CB General-purpose Model Withstands a of 490 kpa (5 kgf/cm 2 ) and highly reliable. Incorporates a two-turn adjuster ensuring
More informationW 30 Photoelectric proximity switches: Clear signals even with low remission
W 0 Photoelectric proximity switches Photoelectric proximity switches, BGS Photoelectric proximity switches, energetic W 0 Photoelectric proximity switches: Clear signals even with low remission In addition,
More informationCALYS 80P. Field pressure calibrator with high accuracy 0.01%
Field pressure calibrator with high accuracy 0.01% CALYS 80P is a field pressure calibrator within CALYS range with high accuracy of 0.01%. Description CALYS 80P is a field pressure calibrator within CALYS
More informationMineral-insulated thermocouples to DIN and EN
Data Sheet 90.1210 (90.1221) Page 1/7 s to DIN 43 710 and EN 60 584 for temperatures from -200 to +1200 C flexible sheath with shock-proof measuring insert protection tube diameter from 0.5mm fast response
More informationPTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30
eries Features Best pressure transmission solution for small and middle sized project such as indoor heating and air conditioning, water and sewer, or incinerator, etc. Improves noise resistance and minimize
More information2D - STRIP ANCHOR LIFTING SYSTEM
2D - STRIP ANCHOR LIFTING SYSTEM WWW.TERWA.COM Terwa reserves the right to make changes to the documentation at any time Page 1 OVERVIEW LIFTING CLUTCHES AND TRANSPORT ANCHOR SA-B SA-ST SA-TTU UNIVERSAL
More informationAIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control
AIR PREPARATION ELECTRONICALLY CONTROLLED PRESSRE REGLATING ALE (PROPORTIONAL PRESSRE REGLATING ALE) SERIES control Description Abb. Port size Recommended Type Data Sheet No. flow (l/min)* airfit tecno
More informationAir velocity & IAQ measuring instruments
Data sheet dp Air velocity & IAQ measuring instruments - air velocity & IAQ measuring instrument - dp air velocity & IAQ measuring instrument incl. differential pressure C CO Intuitive: clearly structured
More informationDirect-operated 2/2-way solenoid valves Type EV210B
Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance
More informationCDS. high density spring connection
CDS high density spring connection DENSTY STANDARD 1A CDS DENSTY A A spring connection CDS Series The originality of multipole connectors represents one of the core values of LE, a leading company in this
More informationISEmax CAM40/CAS40. Technical Information
Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works
More informationHigh Pressure fi lters. FHA 051 series. Maximum working pressure up to 56 MPa (560 bar) - Flow rate up to 140 l/min. High Pressure fi lters
High Pressure fi lters FHA 0 series Maximum working pressure up to 6 MPa (60 bar) Flow rate up to 0 l/min 99 High Pressure fi lters Introduction FILTER SIZG DEX CALCULATION CORRECTIVE FACTOR Page Introduction
More informationCartridge Valves Technical Information. Quick reference
Quick reference Contents CPF0... 8. CP600-5... 8. CP60-5... 8. 066 handle kit... 8.5 MP06... 8.6 MP... 8.6 X05-FD0 Traction manifold... 8.9 X05-FD6 Traction manifold... 8.0 X05-FD0 Traction manifold...
More informationDirect-operated 2/2-way compact solenoid valves Type EV210A
Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together
More informationBody (Black) O-ring Stud. Effective when piping in a confined space. The body and the threaded portion can rotate (For positioning to some extent).
Antistatic One-touch Fittings Tubing: Metric Size/Connection Thread: M, Rc, G, NPT, NPTF Series KA RoS One-touch fitting with antistatic prevention. One-touch IN/OUT connection. Possible to use from vacuum
More informationMIK. Electromagnetic Flowmeter Compact. for conductivity liquids
Electromagnetic Flowmeter Compact for conductivity liquids measuring monitoring analysing MIK MIK with frequency-, switching-, analogue output MIKwith digital plug on display Range from liquids, acids
More informationHARTING D-Sub Selection Guide
HARTING D-Sub Selection Guide People Power Partnership D-Sub Selection Guide D-Sub Device Connectivity HARTING Connectivity & Networks generates solutions throughout the triad of Installation Technology,
More informationMINIATURE MICROSWITCHES - PREMIUM
0/08 MINIATURE MICROSWITCHES - PREMIUM V - 86 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed Broad range of operating forces
More informationEX-EMERGENCY LIGHT FITTINGS
EX-EMERGENCY LIGHT FITTINGS nllk 0...N 1-36 W Plastic version for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 N are conform to the requirements of the ATEX-Directive
More informationIndustrial Pressure Transmitter
ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter
More informationW 34: Sensor technology that does justice to demanding requirements
KD0_W_en.qxd.0.00 : Uhr Seite W Photoelectric switches Photoelectric proximity switches BGS Photoelectric reflex switches Through-beam photoelectric switches W : Sensor technology that does justice to
More informationCALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%
ATEX documenting multifunction calibrator with high accuracy 0.006% is the top instrument of our range of ATEX documenting multifunction calibrators. Description is the top instrument of our range of ATEX
More informationI nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I
I nllk / I x W x W x W x W x W Technical data Cooper Crouse-Hinds - all rights reserved nllk / nllk nllk / nllk nllk / Marking to //EC II G Ex na II T / II D td A IP T C EC Conformity Statement PTB ATEX
More informationTeSys enclosed starters 2
Characteristics, references TeSys enclosed starters D..L. starters for motor control 0. to. kw with -phase thermal overload relay with protected phases Characteristics () Conforming to standards IEC 0--,
More informationLoad Washers. Force kn until kn. Type 9101A A
Force Load Washers 0... 20 kn until 0... 700 kn Type 9101A... 9107A Force sensor for measuring quasistatic and dynamic forces in industrial monitoring tasks. F z The force sensors are delivered uncalibrated
More informationIBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationHigh Pressure fi lters. FMP 039 series. Maximum pressure up to 110 bar - Flow rate up to 80 l/min. High Pressure fi lters
High Pressure fi lters FMP 09 series Maximum pressure up to 0 bar Flow rate up to 80 l/min 7 High Pressure fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop
More informationIBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationTemperature Measurement
Temperature Measurement 157 12 Precise and reliable measurements even in aggressive liquids all probes are encapsulated with PTFE for maximum chemical resistance. PRODUCT TIPS Page 161: 143 PT100 Temperature
More informationProduct description. Developing lighter, more compact and. photoelectric sensor offers completely. ligent features: the sensors feature
W2S-2 Miniature photoelectric sensors Product description Developing lighter, more compact and photoelectric sensor offers completely ligent features: the sensors feature housing size. Whether it is used
More informationSmall Panel with matrix screen
M a g e l i s X B T R, X B T N Small Panel with matrix screen The Magelis XBT Small Panel range is designed to help save you time by satisfying even your most strictest environmental specifi cations. Enjoy
More informationThermal Mass Flow Meter for Gases
Thermal Mass Flow Meter for Gases measuring monitoring analysing Direct mass flow rate measurement of gases Measuring accuracy: ±1.0% f.s. +0.5% m.v. pmax PN 16, tmax 175 C Fast response time No moving
More informationTHERMOCOUPLE CHARACTERISTICS TRAINER
THERMOCOUPLE CHARACTERISTICS TRAINER (Model No : ) User Manual Version 2.0 Technical Clarification /Suggestion : / Technical Support Division, Vi Microsystems Pvt. Ltd., Plot No :75,Electronics Estate,
More informationReturn fi lters. FRI series. Maximum pressure up to 20 bar - Flow rate up to 1500 l/min. Return fi lters
Return fi lters FRI series Maximum pressure up to 0 bar - Flow rate up to 500 l/min 9 Return fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending by
More informationCalio-Therm NC Type Series Booklet
High-efficiency Drinking Water Pump Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,
More informationCooling Water Flow Regulator
Temperature controlled, indirectly and directly actuated diaphragm valves / seat valves Port size G 3/8 to G DN 0 to DN 0 ontinuous regulation High accuracy No auxiliary energy required Technical data
More informationPressure Display Controller
MODEL DW Display Controller Low The Model DW pressure controller accurately monitors and controls very low pressures. It combines in one enclosure a low pressure transducer, a digital display and two alarms
More informationVOLUMEC. Valve Position Indicator 5
VOLUMEC Valve Position Indicator 5 2 KRACHT CORP. 8600 S Wilkinson Way Unit A Perrysburg, OH 43551 USA P +1 419 874 1000 F +1 419 874 1006 flowmeters@krachtcorp.com www.krachtcorp.com VOLUMEC Valve Position
More informationReturn fi lters. MPI series. Maximum working pressure up to 1 MPa (10 bar) - Flow rate up to 3000 l/min
Return fi lters series Maximum working pressure up to MPa (0 bar) Flow rate up to 000 l/min 0 Return fi lters Introduction FILTER SIZING INDEX CALCULATION CORRECTIVE FACTOR Page Introduction Calculation
More informationIntuitive air velocity and IAQ.
Intuitive air velocity and IAQ. The new combines versatility and maximum convenience. 1 The new air velocity & IAQ measuring instrument: versatility in a compact format. Welcome to a new era: the new combines
More informationph Electrode basics ph Electrodes Model 19 B /1 =1 m 24 B /1 =1 m
s ph electrodes are constructed from a special composition which senses the hydrogen ion concentration. This is typically composed of alkali metal ions. The alkali metal ions of the and the hydrogen ions
More informationv = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes
Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes Examples of Application Flow measurements also in hazardous locations X zone 0 or zone 1 in clean rooms in air
More informationVarius SUMMARY OF MODELS OF HRC FUSE-LINKS
SUMMARY OF MODELS OF HRC FUSE-LINKS Type PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationLD-LP-LL-LC Rope Safety Switches with reset for emergency stop
TECHNICA DATASHEET D-P--C Rope Safety Switches with reset for emergency stop Metal or polymer housing, from one or three conduit entries Protection degree IP6 In conformity with EN ISO 13850 contact blocks
More informationMIK. Electromagnetic Flowmeter Compact. for conductivity liquids. Range from liquids, acids and caustic solutions:
Electromagnetic Flowmeter Compact for conductivity liquids measuring monitoring analysing MIK Range from liquids, acids and caustic solutions: 0.0-0. 3-700 l/min frequency-, switching-, analogue output
More informationZF Series Force Transducers
Data Sheet Series Force Transducers FEATURES 1 kn to 00 kn High accuracy For tensile or pressure forces Made of stainless steel Enclosure protection IP 67 DESCRIPTION The force transducers of the series
More information