ThermoScan Ear thermometer

Size: px
Start display at page:

Download "ThermoScan Ear thermometer"

Transcription

1 ThermoScan Ear thermometer IRT 00 IRT 00 IRT 0

2 IRT 00 / 00 0 or Product description IRT 00/00 Series 0 Lens filter (Box of 0) Probe tip Probe ExacTemp light Lens filter ejector Display Power button Start button Battery door Protective cap (IRT 00 only) Protective case (IRT 00 only) IRT 0 Series 0 Lens filter (Box of 0) Probe tip Probe ExacTemp light Lens filter ejector Display Memory button Power button Start button Battery door Protective case The Braun ThermoScan thermometer has been carefully developed for accurate, safe and fast temperature measurements in the ear. The shape of the thermometer probe prevents it from being inserted too far into the ear canal which can hurt the eardrum. However, as with any thermometer, proper technique is critical to obtaining accurate temperatures. Therefore, read the instructions carefully and thoroughly. The Braun ThermoScan thermometer is intended for intermittent measurement and monitoring of human body temperature for people of all ages. It is intended for household use only. Use of this thermometer is not intended as a substitute for consultation with your physician. IRT 0 WARNINGS AND PRECAUTIONS 0 Please consult your doctor if you see symptoms such as unexplained irritability, vomiting, diarrhea, dehydration, changes in appetite or activity, seizure, muscle pain, shivering, stiff neck, pain when urinating, etc. in spite of absence of fever. Please consult your doctor if the thermometer shows elevated temperature. The operating ambient temperature range for this thermometer is 0 0 F (0 0 C). Do not expose the thermometer to temperature extremes (below F / C or over F / C) or excessive humidity (> % RH). This thermometer must only be used with genuine Braun ThermoScan lens filters (LF 0). To avoid inaccurate measurements always use this thermometer with a new, clean lens filter attached. If the thermometer is accidentally used without a lens filter attached, clean the lens (see «Care and cleaning» section). Keep lens filters out of reach of children. This thermometer is intended for household use only. Use of this thermometer is not intended as a substitute for consultation with your physician. This thermometer is not intended for pre-term babies or small-for-gestational age babies. It is not intended to interpret hypothermic temperatures. Do not allow children under years to take their temperature unattended. Do not modify this equipment without authorization of the manufacturer.

3 Parents/guardians should call the pediatrician upon noticing any unusual sign(s) or symptom(s). For example, a child who exhibits irritability, vomiting, diarrhea, dehydration, seizure, changes in appetite or activity, even in the absence of fever, or who exhibits a low temperature, may still need to receive medical attention. People who are on antibiotics, analgesics, or antipyretics should not be assessed solely on temperature readings to determine the severity of their illness. Temperature elevation may signal a serious illness, especially in neonates and infants, or in adults who are old, frail, or have a weakened immune system. Please seek professional advice immediately when there is a temperature elevation and if you are taking temperature on: Neonates and infants under months (Consult your physician immediately if the temperature exceeds. F or. C). Patients over 0 years of age (Fever may be blunted or absent in older patients). Patients having diabetes mellitus or a weakened immune system (e.g., HIV positive, cancer chemotherapy, chronic steroid treatment, splenectomy) Patients who are bedridden (e.g., nursing home patient, stroke, chronic illness, recovering from surgery) A transplant patient (e.g., liver, heart, lung, kidney). This thermometer contains small parts that can be swallowed or produce a choking hazard to children. Keep out of reach of children under years. Why measure in the ear? The goal of thermometry is to measure core body temperature which is the temperature of the vital organs. Ear temperatures accurately reflect core body temperature, since the eardrum shares blood supply with the temperature control center in the brain, the hypothalamus. Therefore, changes in body temperature are reflected sooner in the ear than at other sites. Axillary temperatures measure skin temperature and may not be a reliable indicator of core body temperature. Oral temperatures are influenced by drinking, eating and mouth breathing. Rectal temperatures often lag behind changes in core body temperature and there is a risk of cross-contamination. How to use your Braun ThermoScan Remove the Remove protective cap. IRT 00 IRT 0 thermometer from the protective case. IRT 00 Body temperature Normal body temperature is a range. It varies by site of measurement, and it tends to decrease with age. It also varies from person to person and fluctuates throughout the day. Therefore, it is important to determine normal temperature ranges. This is easily done using Braun ThermoScan. Practice taking temperatures on yourself and healthy family members to determine the normal temperature range. Note: When consulting your physician, communicate that the ThermoScan temperature is a temperature measured in the ear and if possible, note the individual s normal ThermoScan temperature range as additional reference. Push the Power button. During an internal self-check, the display shows all segments. Then the last temperature taken will be displayed for seconds. How does Braun ThermoScan work? Braun ThermoScan measures the infrared heat generated by the eardrum and surrounding tissues. To help avoid inaccurate temperature measurements, the probe tip is warmed to a temperature close to that of the human body. When the Braun ThermoScan is placed in the ear, it continuously monitors the infrared energy. The measurement is finished and the result displayed when the thermometer detects that an accurate temperature measurement has been taken. The lens filter indicator will blink to signal one is needed. To achieve accurate measurements, make sure a new, clean lens filter is in place before each measurement. Attach a new lens filter by pushing the thermometer probe straight into the lens filter inside the box and then pulling out. Note: The Braun ThermoScan will not work unless a lens filter is attached. The thermometer is ready to take a temperature when the display looks like the images below.. Guyton A C, Textbook of medical physiology, W.B. Saunders, Philadelphia,, p. Guyton A C, Textbook of medical physiology, W.B. Saunders, Philadelphia,, p -. Netter H F, Atlas of Human Anatomy, Novartis Medical Education, East Hanover, NJ,, pp,.

4 Fit the probe snuggly into the ear canal, then push and release the Start button. Temperature taking hints Always replace disposable lens filters to maintain accuracy and hygiene. The right ear measurement may differ from the measurement taken in the left ear. Therefore, always take the temperature in the same ear. The ear must be free from obstructions or excess earwax build-up to take an accurate reading. External factors may influence ear temperatures, including: ExacTemp light will pulse while temperature is in progress. The light will remain solid for seconds to indicate that a successful temperature reading has been achieved. NOTE: If the probe has been properly inserted into the ear canal during the measurement, a long beep will sound to signal the completed measurement. If the probe has NOT been constantly placed in a stable position in the ear canal, a sequence of short beeps will sound, the ExacTemp light will go out and the display will show an error message (POS = position error). See «Errors and troubleshooting» section for more information Factor Yes affects Poor probe placement Used lens filter Dirty lens In the cases below, wait 0 minutes prior to taking a temperature. Factor Yes affects Extreme hot and cold room temperature Hearing aid Lying on pillow Use the untreated ear if ear drops or other ear medications have been placed in the ear canal. Memory mode The confirmation beep indicates that an accurate temperature measurement has been taken. The result is shown on the display. The last temperature taken is stored in the memory and will be automatically displayed for seconds when it is turned on again. For the next measurement, press Eject button to remove and discard used lens filter, and put on a new, clean lens filter. The Braun ThermoScan ear thermometer turns off automatically after 0 seconds of inactivity. The thermometer can also be turned off by pressing the Power button. The display will briefly flash OFF and it will go blank. Available only in IRT 0 This model stores the last temperature measurements. To display the stored measurement, the thermometer must be turned on. Press the Mem button. The display shows the temperature, and when releasing the Mem button, the stored temperature for that memory number is displayed, together with M. Each time the Mem button is pushed, the stored reading and an M is displayed to indicate each temperature measurement (eg. M). Memory mode is automatically exited by not pressing the memory button for seconds.

5 Available only in IRT 0 Night light feature Changing the temperature scale If you wish to change the temperature scale of your thermometer: This thermometer includes a convenient night light to illuminate the display in a dim environment. The light will turn on when you press any button. It will stay on until the thermometer is inactive for up to seconds even after temperature is taken. Make sure the thermometer is turned off. Press and hold down the Power button. After about seconds the display will show this sequence: C / SET / F / SET... sec Release the Power button when the desired temperature scale is shown. There will be a short beep to confirm the new setting, then the thermometer is turned off automatically. sec Calibration The thermometer is initially calibrated at the time of manufacture. If this thermometer is used according to the use instructions, periodic re-adjustment is not required. If at any time you question the accuracy of temperature measurements, please contact Consumer Relations. Manufacturing date is given by the LOT number located inside the battery compartment. The first three () digits after LOT represent the Julian date that the product was manufactured and the next two () digits represent the last two numbers of the calendar year the product was manufactured. The last identifiers are the letters that represent the manufacturer. An example: LOT KTC, this product has been manufactured on the th day of the year 0. Errors and troubleshooting Error Message Situation No lens filter is attached. Solution Attach new, clean lens filter. Care and cleaning The probe tip is the most delicate part of the thermometer. It must be clean and intact to ensure accurate readings. If the thermometer is ever accidentally used without a lens filter, clean the probe tip as follows: Very gently wipe the surface with a cotton swab or soft cloth moistened with alcohol. After the alcohol has completely dried out, you can put a new lens filter on and take a temperature measurement. If the probe tip is damaged, please contact Consumer Relations. Use a soft, dry cloth to clean the thermometer display and exterior. Do not use abrasive cleaners. Never submerge this thermometer in water or any other liquid. Store thermometer and lens filters in a dry location free from dust and contamination and away from direct sunlight. Additional lens filters (LF 0) are available at most stores carrying Braun ThermoScan. Replacing the batteries The thermometer is supplied with two. V type AA (LR 0) batteries. For best performance, we recommend Duracell alkaline batteries. The thermometer probe was not positioned securely in the ear. An accurate measurement was not possible. POS = position error Ambient temperature is not within the allowed operating range (0 0 F or 0 0 C ). Temperature taken is not within typical human temperature range (. 0 F or. C). HI = too high LO = too low Take care that the positioning of the probe is correct and remains stable. Replace lens filter and reposition. Press Start button to begin a new measurement. Allow the thermometer to remain for 0 minutes in a room where the temperature is between 0 and 0 F or 0 and 0 C. Make sure the probe tip and lens are clean and a new, clean lens filter is attached. Make sure the thermometer is properly inserted. Then, take a new temperature. Insert new batteries when the battery symbol appears on the display. Open the battery compartment. Remove the batteries and replace with new batteries, making sure the poles are in the right direction. System error self-check display flashes continuously and will not be followed by the ready beep and the ready symbol. Wait minute until the thermometer turns off automatically, then turn on again. Snap battery door into place. If error persists,... reset the thermometer by removing the batteries and putting them back in. To protect the environment, dispose of the product and empty batteries at your retail store or at appropriate collection sites according to national or local regulations. If error still persists, Battery is low, but thermometer will still operate correctly. please contact Customer Service. Insert new batteries. Battery is too low to take correct temperature measurement. Insert new batteries.

6 Product specifications Displayed temperature range:. 0 F (. C) Operating ambient temperature range: 0 0 F (0 0 C) Display resolution: 0. F or C Accuracy for displayed temperature range Maximum Laboratory Error F 0. F ( C C): ± 0. F ± 0. C outside this range: ± 0. F ± 0. C clinical repeatability: ± 0. F ± 0. C Long term storage ranges Storage/transport temperature: - F to F (- C to C) Humidity: -% non condensing Battery life: years / 00 measurements Service life: years This thermometer is specified to operate at atmospheric pressure (00-00hPA) or at altitudes with an atmospheric pressure up to atmospheric pressure (00-00hPA). Equipment with type BF applied parts See instruction for use 0 F (0 C) 0 F (0 C) Operating temperature Keep it dry Attention, consult ACCOMPANYING DOCUMENTS Subject to change without notice. This appliance conforms to the following standards: Standard Reference Edition Title: EN 0-: 00 Clinical thermometers - Part : Performance of infra-red ear thermometers (with maximum device). EN 00-: 00 Medical electrical equipment Part : General requirements for basic safety and essential performance. EN ISO : 0 Medical devices Application of risk management to medical devices. EN ISO 0-: 00 Biological evaluation of medical devices Part : Evaluation and Testing within a risk management process. EN 00--: 00 Medical electrical equipment part -: General requirements for basic safety and essential performance Collateral standard: electromagnetic compatibility Requirements and tests EN 0: 00 Symbols for use in labeling of medical devices. EN 0: 00 Information supplied by the manufacturer of medical devices. EN 00--: 00 Medical electrical equipment -- Part -: General requirements for basic safety and essential performance -- Collateral standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment. This product conforms to the provisions of the EC directive //EEC. MEDICAL ELECTRICAL EQUIPMENT needs special precautions regarding EMC. For detailed description of EMC requirements please contact Customer Service. Portable and mobile RF communications equipment can affect MEDICAL ELECTRICAL EQUIPMENT. Please do not dispose of the product in the household waste at the end of it useful life. To protect the environment, dispose of empty batteries at appropriate collection sites according to national or local regulations. Guidance and manufacturer s declaration electromagnetic emissions The ME equipment is intended for use in the electromagnetic environment specified below. The customer or the user of the ME equipment should ensure that it is used in such an environment. Emissions Test Compliance Electromagnetic environment guidance RF Emissions CISPR RF Emissions CISPR Harmonic emissions IEC Voltage fluctuations / flicker emissions Rated maximum output power of transmitter (W) Group Class B The ME equipment uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment. Complies The ME equipment is solely battery powered. Non-Life Support Equipment Separation Distance Calculation (Vrms / V/m compliance) Separation distance according to frequency of transmitter (m) Guidance and manufacturer s declaration electromagnetic immunity The ME equipment is intended for use in the electromagnetic environment specified below. The customer or the user of the ME equipment should ensure that it is used in such an environment. Immunity test IEC 00 test level Compliance level Electromagnetic environment guidance Electrostatic discharge (ESD) IEC Radiated RF IEC Conducted RF IEC Electrical fast transient IEC Surge IEC Power frequency magnetic field IEC khz to 0 MHz in ISM bands 0 MHz to 00 MHz 00 MHz to. GHz d = [, V ] P d = [, E ] P d = [ E ] P ±kv Contact ±kv Air Complies V/m 0MHz to.ghz Complies Vrms 0kHz to 0MHz ±kv power line ±kv I/O lines ±kv differential ±kv common (no electrical cabling) A/m Complies Floors should be wood, concrete, or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 0%. Field strengths outside the shielded location from fixed RF transmitters, as determined by an electromagnetic site survey, should be less than V/m. Interference may occur in the vicinity of equipment marked with the following symbol: Separation distance calculation provided above. If a known transmitter is present the specific distance can be calculated using the equations. The ME equipment is solely battery powered. Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment. Voltage dips, short interruptions and voltage variations on power supply input lines IEC >% dip 0. cycle 0% dip cycles 0% dip cycles % dip sec. The ME equipment is solely battery powered.

DIAGNOSTICS NO TOUCH FOREHEAD THERMOMETER

DIAGNOSTICS NO TOUCH FOREHEAD THERMOMETER DIAGNOSTICS NO TOUCH FOREHEAD THERMOMETER nu-beca NO TOUCH THERMOMETER : Thank you for purchasing the nu-beca No Touch Forehead Thermometer. Please read this instruction manual first so you can use this

More information

CCQ-800 AutoFocimeter. CCQ-800 AutoFocimeter. Operating Instruction. R/No.: CCQ8.0ESM REV: 3.45

CCQ-800 AutoFocimeter. CCQ-800 AutoFocimeter. Operating Instruction. R/No.: CCQ8.0ESM REV: 3.45 R/No.: CCQ8.0ESM REV: 3.45 CCQ-800 AutoFocimeter CCQ-800 AutoFocimeter Operating Instruction Add: 5 Danlong Road, Nan'an District, Chongqing,400060,China Tel : (00 86)-(0)23 62797666 Fax: (00 86)-(0)23

More information

Non - Contact Forehead Infrared Thermometer. Care Q7 USER MANUAL - 1 -

Non - Contact Forehead Infrared Thermometer. Care Q7 USER MANUAL - 1 - Non - Contact Forehead Infrared Thermometer Care Q7 USER MANUAL - 1 - Contents: 1. Introduction... 1 2. Safety precautions... 1 3. Features... 2 4. Product description... 2 5. Display description... 3

More information

MICROLIFE THERMO+ Infrared Thermometer. For safe, touch-free temperature measurement. Instruction Manual

MICROLIFE THERMO+ Infrared Thermometer. For safe, touch-free temperature measurement. Instruction Manual MICROLIFE THERMO+ Infrared Thermometer For safe, touch-free temperature measurement Instruction Manual a EN Dear Customer, We thank you for purchasing the Microlife Thermo+, the infrared thermometer that

More information

Nanostim Programmer Link S1LINK. Instructions for Use

Nanostim Programmer Link S1LINK. Instructions for Use Nanostim Programmer Link S1LINK Instructions for Use Covered by one or more of the following US patents: 7,945,333, 8,295,939, 8,352,025, 8,457,742 Unless otherwise noted, indicates that the name is a

More information

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer INSTRUCTION MANUAL Thermometer DUAL-LASER TARGETING 12:1 DISTANCE- TO-SPOT RATIO AUTO-SCAN MAX/MIN/AVG/DIFF HIGH/LOW ALARM BACKLIT DISPLAY AUTO POWER-OFF ADJUSTABLE EMISSIVITY IR5 2m -22 752 F (-30 400

More information

FIG. 1 FIG. 2 FIG. 3 FIG. 4 FIG. 5 FIG. 6 FIG. 7

FIG. 1 FIG. 2 FIG. 3 FIG. 4 FIG. 5 FIG. 6 FIG. 7 OK FIG. 1 FIG. 2 FIG. 3 FIG. 4 FIG. 5 FIG. 6 FIG. 7 OK INTRODUCTION Please read all the instructions carefully before using the thermometer 1. Thermofocus is exceptionally easy to use to take a body temperature

More information

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual Latest generation testo air velocity & IAQ probes with cable handle Instruction manual Contents Contents 1 About this document... 5 2 Safety and disposal... 5 3 System description... 6 4 Description of

More information

Instructions for use: Pushtronex System for Repatha (ri-path-a) (evolocumab) Single-Use On-Body Infusor and Prefilled Cartridge.

Instructions for use: Pushtronex System for Repatha (ri-path-a) (evolocumab) Single-Use On-Body Infusor and Prefilled Cartridge. Instructions for use: Pushtronex System for Repatha (ri-path-a) (evolocumab) Single-Use On-Body Infusor and Prefilled Cartridge Guide to parts Prefilled Cartridge White plunger Cartridge top (Do not rotate)

More information

User Manual VX4750 Function Generator Module

User Manual VX4750 Function Generator Module User Manual VX4750 Function Generator Module 070-9151-05 This document applies for firmware version 2.60 and above. Copyright Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S.

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS Model IQ120 and IQ125 Professional ph Meter with Silicon Chip Sensor (IQ125 additional instructions printed in RED) IQ Scientific Instruments 2075-E Corte del Nogal Carlsbad, CA

More information

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet: abc instruments international FLT5A Thermometer Land Instruments International Dronfield, S18 1DJ England Telephone: (1246) 417691 Facsimile: (1246) 41585 Email: infrared.sales@landinst.com Internet: www.landinst.com

More information

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual WD1063 Rev B Revised 02/23/15 Wahl Instruments Inc. 234 Old Weaverville Road Asheville, NC 28804 Toll Free: 800-421-2853 Phone: 828-658-3131

More information

Hazard Communication & Chemical Safety. Based on OSHA Standard

Hazard Communication & Chemical Safety. Based on OSHA Standard Hazard Communication & Chemical Safety Based on OSHA Standard 1910.1200 We use many chemicals We want you to know how to use them safely You will learn about The Hazards of Chemicals Our Written Program

More information

2.8-1 SCIENCE EXPERIMENTS ON FILE Revised Edition. Dew Formation

2.8-1 SCIENCE EXPERIMENTS ON FILE Revised Edition. Dew Formation 2.8-1 SCIENCE EXPERIMENTS ON FILE Revised Edition Dew Formation Topic Dew Time 30 minutes! Safety Please click on the safety icon to view safety precautions. Be careful using the thermometer. Be careful

More information

B Left-hand case side (x1) F

B Left-hand case side (x1) F MD693/ HD-1688 WOODEN RADIO-CONTROLLED GRANDFATHER CLOCK WITH WESTMINSTER CHIMES INSTRUCTIONS PLEASE READ ALL THE INSTRUCTIONS CAREFULLY BEFORE YOU SET YOUR CLOCK GOING AND ENSURE YOU KEEP HOLD OF THESE

More information

Today s Weather 24 Hour Forecaster

Today s Weather 24 Hour Forecaster 1380 Today s Weather 24 Hour Forecaster Instruction Manual The Taylor 24 Hour Forecaster will provide you with actual current temperatures. Predict the weather conditions for the next 24 hours as well

More information

RADIATION-METER TM-91/TM-92

RADIATION-METER TM-91/TM-92 RADIATION-METER TM-91/TM-92 User s Manual EN 1 / 16 CONTENTS 1. introduction... 3 2. Safety Precaution... 4 3. Specification... 6 4. Identifying parts... 7 5. Operation Procedure... 8 6. Battery Replacement...

More information

GPS Scout Backtrack Altimeter Model: GP123 USER MANUAL

GPS Scout Backtrack Altimeter Model: GP123 USER MANUAL INDEX GPS Scout Backtrack Altimeter Model: GP123 USER MANUAL Introduction...2 Overview...2 Front view...2 LCD screen...3 Battery replacement...3 Displays...4 Operation modes...4 Time / date / alarm...4

More information

The only NO CONTACT technology for Pandemic Situations that projects the temperature on the forehead Advantages of VISIOFOCUS Pro

The only NO CONTACT technology for Pandemic Situations that projects the temperature on the forehead Advantages of VISIOFOCUS Pro The only NO CONTACT technology for Pandemic Situations that projects the temperature on the forehead Advantages of VISIOFOCUS Pro Exclusive patented aiming system guarantees correct point and distance.

More information

Wireless Weather Station. Instruction Manual

Wireless Weather Station. Instruction Manual Wireless Weather Station Instruction Manual Congratulations on purchasing this state-of-the-art Weather Station as an example of fine design and quality piece of engineering. The operation of this product

More information

MODE button MAX/MIN button CHANNEL button / C/ F / RCC button SNOOZE / LIGHT button Battery compartment A/C in-jack 3. 4.

MODE button MAX/MIN button CHANNEL button / C/ F / RCC button SNOOZE / LIGHT button Battery compartment A/C in-jack 3. 4. KL4912 Desktop weather station Instruction Manual Introduction This weather station comes with backlight, indoor and outdoor temperature & humidity display, and alarm clock with calendar. Fig. 1 Front

More information

Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL

Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL TABLE OF CONTENTS TITLE PAGE INTRODUCTION...1. SAFETY INFORMATION...2. FEATURES...4. SPECIFICATIONS...4.

More information

U.S. Atomic Clock & Weather Station. Instruction Manual

U.S. Atomic Clock & Weather Station. Instruction Manual U.S. Atomic Clock & Weather Station Instruction Manual Table of Contents What is Atomic Radio Control?... 2 Parts Diagram... 3 Batteries... 4 Setting the Atomic Time and Date... 4 Setting the Clock...

More information

NukEx Nucleic Acid Release Reagent

NukEx Nucleic Acid Release Reagent Instruction for Use NukEx Nucleic Acid Release Reagent For general laboratory use. For in vitro use only. Reagent for the enzymatic release of nucleic acid from tissue samples, ticks, insects and swabs.

More information

N) manual. Biomaster Operating manual

N) manual. Biomaster Operating manual 830 ual N) manual Operating manual Copyright 2013 Eppendorf AG, Hamburg. No part of this publication may be reproduced without the prior permission of the copyright owner. Trademarks Eppendorf and the

More information

A clock designed in close consultation with people living with Dementia.

A clock designed in close consultation with people living with Dementia. 1. Product Name Day Clock 2. Product Code 55787 3. Colour As shown 4. Brief Description A clock designed in close consultation with people living with Dementia. 5. Contents 1 x Day Clock 6. Snoezelen Stimulations

More information

HL-800K Infrared Laser Thermometer. -50 C to +800 C (13:1 ratio) User Manual

HL-800K Infrared Laser Thermometer. -50 C to +800 C (13:1 ratio) User Manual HL-800K Infrared Laser Thermometer -50 C to +800 C (13:1 ratio) User Manual TABLE OF CONTENTS INTRODUCTION... 3 FEATURES... 3 WIDE APPLICATION RANGE... 3 SAFETY... 3 DISTANCE & SPOT SIZE... 4 SPECIFICATIONS...

More information

Hadrons Desktop U.S. Atomic Clock & Weather Station

Hadrons Desktop U.S. Atomic Clock & Weather Station Hadrons Desktop U.S. Atomic Clock & Weather Station SN004 Instructions Read and save these instructions. Dear Sharper Image Customer, Thank you for your purchase of a Sharper Image product. We appreciate

More information

GENERAL INSTRUCTIONS GENERAL PREPARATION

GENERAL INSTRUCTIONS GENERAL PREPARATION GENERAL INSTRUCTIONS Introduction The Van London-pHoenix Company Ammonium Ion Selective Electrode is used to quickly, simply, accurately, and economically measure potassium in aqueous solutions. Required

More information

The only NON CONTACT thermometer that projects the temperature on the forehead

The only NON CONTACT thermometer that projects the temperature on the forehead The only NON CONTACT thermometer that projects the temperature on the forehead Advantages of VISIOFOCUS Pro Exclusive patented aiming system guarantees correct point and distance. Projection of the temperature

More information

InfraRed Thermometer with Laser Pointer

InfraRed Thermometer with Laser Pointer User Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com InfraRed Thermometer with Laser Pointer MODEL IR400 Introduction Congratulations

More information

EXERCISE 7: AUTOMATED HEMOGLOBIN TESTING. Skills: 30 points. Objectives:

EXERCISE 7: AUTOMATED HEMOGLOBIN TESTING. Skills: 30 points. Objectives: EXERCISE 7: AUTOMATED HEMOGLOBIN TESTING Objectives: Skills: 30 points 1. Define the following: hemoglobin, anemia, polycythemia. 2. State two possible causes of anemia and polycythemia 3. State the principle

More information

ENHANCEMENTS Lash Boost is only to be used as directed by one person. It is not to be shared with other people.

ENHANCEMENTS Lash Boost is only to be used as directed by one person. It is not to be shared with other people. F R E Q U E N T L Y A S K E D Q U E S T I O N S RODAN + FIELDS ENHANCEMENTS LASH BOOST TM W H A T I S E N H A N C E M E N T S L A S H B O O S T? A nightly eyelash conditioning serum that pairs with any

More information

WS-9018U Wireless Weather Station. Instruction Manual

WS-9018U Wireless Weather Station. Instruction Manual WS-9018U Wireless Weather Station Instruction Manual Contents Page 1. Functions of the Weather Station....3 2. Safety notes...3 3. Product features....4 4. Getting started....4 5. Quick Set Up...5 6. Setting

More information

INFRARED THERMOMETER TM0819

INFRARED THERMOMETER TM0819 INFRARED THERMOMETER Instruction Manual HORMES LIMITED cs@perfectprime.com G/F UNIT 3, 61 GLENTHORNE ROAD, LONDON W6 0LJ UNITED KINGDOM +44 203 7695377 Retailer Email Address Telephone P.1 CONTENTS 1.

More information

ea980r Digital Anemometer User Manual

ea980r Digital Anemometer User Manual ea980r Digital Anemometer User Manual 1. Overview Thank you for purchasing the ennologic ea980r anemometer, a high quality instrument which measures 8 parameters: Wind Speed (mph, m/s, ft/min, knots, km/h)

More information

What is the maximum distance I can have the remote sensors from the display?

What is the maximum distance I can have the remote sensors from the display? What is the maximum distance I can have the remote sensors from the display? The maximum open-air distance is 100 meters in a straight line although you should take into account the environment, distance

More information

Infusor / Intermate Patient Guide

Infusor / Intermate Patient Guide Infusor / Intermate Patient Guide How should Baxter Infusor/ Intermate be stored? An Infusor/Intermate is a disposable device that is pre-filled with solution that your Doctor has prescribed. You may be

More information

ph electrode Instruction Manual For use with the RAH-210 & RPH-250

ph electrode Instruction Manual For use with the RAH-210 & RPH-250 ph electrode Instruction Manual For use with the RAH-210 & RPH-250 The information in this manual was current at the time of printing. The most current versions of all Hydro Instruments manuals can be

More information

Superconductivity. Never store liquid nitrogen in a container with a tight fitting lid.

Superconductivity. Never store liquid nitrogen in a container with a tight fitting lid. Superconductivity 1 Introduction In this lab we will do some very simple experiments involving superconductors. You will not have to take much data; much of what you do will be qualitative. However, in

More information

Sitting height... 6 Back tilt and back height... 6 Armrest... 7 Brakes... 7 Charging VELA Tango 300E... 7

Sitting height... 6 Back tilt and back height... 6 Armrest... 7 Brakes... 7 Charging VELA Tango 300E... 7 U K u s e r m a n u a l w w w. v e l a. E U contents 1.0. introduction...................................................... 3 1.1. guarantee......................................................... 4

More information

Gun-Type Professional Infrared Thermometer MODEL: ST 653. Instruction Manual

Gun-Type Professional Infrared Thermometer MODEL: ST 653. Instruction Manual Gun-Type Professional Infrared Thermometer MODEL: ST 653 Instruction Manual Gun-Type Professional Infrared Thermometer Instruction Manual Table Content 1.Product Introduction 1-1 Features 1-2 Applications

More information

ELECTRIC DOUBLE LAYER CAPACITORS

ELECTRIC DOUBLE LAYER CAPACITORS Application Guidelines for Using Electric Double Layer Capacitor (EDLC) 1. Circuit Design Ensure that operational and mounting conditions follow the specified conditions detailed in the catalog and specification

More information

Vet Photometer DP 700 Operating Manual. Version V5.9

Vet Photometer DP 700 Operating Manual. Version V5.9 1 Vet Photometer DP 700 Operating Manual Version V5.9 2 Dear customer, Thank you for selecting Diaglobal s Vet Photometer and for the confidence you have placed in us. The Vet Photometer belongs to a new

More information

SECTION 3 PRODUCT COMPOSITION The test kit is composed of QuSTICK Strep A Reagent Stick, Reagent A, Reagent B, Positive Control, and Negative Control.

SECTION 3 PRODUCT COMPOSITION The test kit is composed of QuSTICK Strep A Reagent Stick, Reagent A, Reagent B, Positive Control, and Negative Control. SECTION 1 PRODUCT AND COMPANY IDENTIFICATION Product Identification: Ref No. 6000, 6000-025, etc. Test kit contains QuSTICK Strep A Reagent Stick, Reagent A, Reagent B, Positive Control, and Negative Control.

More information

Completion Match each each piece of equipment with its description. Please only put one number in the blank.

Completion Match each each piece of equipment with its description. Please only put one number in the blank. LAB SAFETY AND EQUIPMENT TEST Completion Match each each piece of equipment with its description. Please only put one number in the blank. 1. Used for filtering and for adding chemicals without spilling.

More information

COMMODORE BRASS TELESCOPE ZHUMELL COMMODORE BRASS TELESCOPE

COMMODORE BRASS TELESCOPE ZHUMELL COMMODORE BRASS TELESCOPE 3 0 15 15 E OWNER S MANUAL COMMODORE BRASS TELESCOPE ZHUMELL COMMODORE BRASS TELESCOPE 5 W 60 W 30 W 45 W Zhumell customers know that there are plenty of ways to experience the world. They also understand

More information

Instruction Manual SEFRAM Thermal Camera

Instruction Manual SEFRAM Thermal Camera Instruction Manual SEFRAM 9830 Thermal Camera EN Introduction The SEFRAM 9830 Thermal Camera (the Product) can display thermal gradient, temperature readings, map and measure the infrared energy radiated

More information

Rapid RH Portable ph Meter. User's Manual

Rapid RH Portable ph Meter. User's Manual Rapid RH Portable ph Meter User's Manual This page intentionally left blank. 2 Contents 1. Introduction... 4 2. Included with the Rapid RH Portable ph Meter... 4 3. Understanding ph... 5 4. Calibrating

More information

GENERAL INSTRUCTIONS GENERAL PREPARATION

GENERAL INSTRUCTIONS GENERAL PREPARATION GENERAL INSTRUCTIONS Introduction The Van London-pHoenix Company Fluoroborate Ion Selective Electrode is used to quickly, simply, accurately, and economically measure Fluoroborate in aqueous solutions.

More information

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER Model : TM-2000 Your purchase of this THERMOMETER marks a step forward for you into the field of precision measurement. Although this THERMOMETER is a

More information

INFRARED THERMOMETER Model : TM-959

INFRARED THERMOMETER Model : TM-959 LED target light, Emissivity adjustment INFRARED THERMOMETER Model : TM-959 Your purchase of this I N F R A R E D THERMOMETER marks a step forward for you into the field of precision measurement. Although

More information

BIOS. Weather. 266BC Wireless Wind Chill and Humidex Thermometer. Thermomètre sans fil pour indices de refroidissement éolien et humidex

BIOS. Weather. 266BC Wireless Wind Chill and Humidex Thermometer. Thermomètre sans fil pour indices de refroidissement éolien et humidex Weather BIOS 266BC Wireless Wind Chill and Humidex Thermometer Thermomètre sans fil pour indices de refroidissement éolien et humidex Monitor/Moniteur ite r : 4. 5. 6. A. B. C. D. E. 1. 2. 3. Transmitter/Transmetteur

More information

These are just basic training slides, may vary from standards. Basic First Aid. 1

These are just basic training slides, may vary from standards. Basic First Aid.   1 These are just basic training slides, may vary from standards Basic First Aid www.askmaaz.com 1 What is 1 st Aid First Aid is an immediate and temporary care given to a victim of an accident or sudden

More information

State Unitary Enterprise Production Amalgamation Novosibirsk Instrument-Making Plant PN-6K. Servise Manual

State Unitary Enterprise Production Amalgamation Novosibirsk Instrument-Making Plant PN-6K. Servise Manual State Unitary Enterprise Production Amalgamation Novosibirsk Instrument-Making Plant Night Sight PN-6K Servise Manual Contents 1. General directions 4 2. Specifications 5 3. Delivery set 6 4. Safety regulations

More information

INTRODUCTION TO ENGINEERING SURVEYING (CE 1305)

INTRODUCTION TO ENGINEERING SURVEYING (CE 1305) INTRODUCTION TO ENGINEERING SURVEYING (CE 1305) Linear Measurements Sr Dr. Tan Liat Choon Email: tanliatchoon@gmail.com Mobile: 016-4975551 1 EDM, TOTAL STATION, PRISM AND POLE 2 ELECTROMAGNETIC DISTANCE

More information

Hazard Communication for Dangerous and Harmful Materials

Hazard Communication for Dangerous and Harmful Materials Hazard Communication for Dangerous and Harmful Materials Yu-Li Huang Department of Safety, Health and Environmental Engineering National Kaohsiung First University of Science & Technology 1 Outline Overview

More information

Newton s Second Law of Motion

Newton s Second Law of Motion Newton s Second Law of Motion Topic Newton s second law of motion describes how acceleration is related to force and mass. Introduction Newton s second law of motion states that the acceleration of an

More information

Standard Operating Procedure

Standard Operating Procedure Standard Operating Procedure Procedure Radioimmunoassay with I Department Location SOP Prepared By: Section 1: Purpose Radioimmunoassays are used for detecting the concentration of a specific antigen or

More information

TG646 WEATHER STATION

TG646 WEATHER STATION TG646 WEATHER STATION WITH REMOTE SENSOR User Manual CONGRATULATIONS ON PURCHASING THE THINK GIZMOS WIRELESS WEATHER STATION. BY FOLLOWING THESE INSTRUCTIONS CAREFULLY IT WILL BE A GREAT ASSET IN YOUR

More information

CONTENTS. Batteries. La Crosse Technology, Ltd Page 1

CONTENTS. Batteries. La Crosse Technology, Ltd Page 1 515-1316 FAQS The links below will work in most PDF viewers and link to the topic area by clicking the link. We recommend Adobe Reader version 10 or greater available at: http://get.adobe.com/reader CONTENTS

More information

TECHNICAL MANUAL 820 LX / 910 LX / 1300 LX

TECHNICAL MANUAL 820 LX / 910 LX / 1300 LX TECHNICAL MANUAL 820 LX / 910 LX / 1300 LX LANCER reserves the right to modify, constantly its documentation for its improvement. The values of adjustments indicated in the displays of this manual are

More information

Plant Indicators for Acids and Bases

Plant Indicators for Acids and Bases SCIENCE EXPERIMENTS ON FILE Revised Edition 5.28-1 Plant Indicators for Acids and Bases Carole R. Goshorn Topic Acid/base indicators Time Preparation by teacher 50 minutes; Part B, 45 minutes! Safety Adult

More information

The Weather Station FEATURES:

The Weather Station FEATURES: WIRELESS 433MHz WEATHER STATION Instructions Manual INTRODUCTION: Congratulations on purchasing this Weather Station with wireless 433MHz transmission of outdoor temperature and display of indoor temperature

More information

EXERCISE 9: AUTOMATED HEMOGLOBIN TESTING

EXERCISE 9: AUTOMATED HEMOGLOBIN TESTING EXERCISE 9: AUTOMATED HEMOGLOBIN TESTING Textbook: Skills: 34 points Objectives: 1. Define the following: hemoglobin, anemia, polycythemia, sulfhemoglobin, carboxyhemoglobin 2. State two possible causes

More information

WS-7047TWC Wireless 433 MHz Weather Station With Rainfall and Temperature. Instruction Manual

WS-7047TWC Wireless 433 MHz Weather Station With Rainfall and Temperature. Instruction Manual WS-7047TWC Wireless 433 MHz Weather Station With Rainfall and Temperature Instruction Manual TABLE OF CONTENTS Topic Page Inventory of Contents 2 Additional Equipment 2 Quick Setup 3 Detailed Setup Guide

More information

PRODUCT SAFETY SUMMARY (GPS) SODIUM-HYDROXIDE

PRODUCT SAFETY SUMMARY (GPS) SODIUM-HYDROXIDE This Product Safety Summary is intended to provide a general overview of the chemical substance in the context of ICCA (International Council of Chemical Associations) Global Product Strategy. The information

More information

XR Analog Clock - Manual Setting Model Troubleshooting Guide

XR Analog Clock - Manual Setting Model Troubleshooting Guide Primex XR 72MHz Synchronized Time Solution XR Analog Clock - Manual Setting Model Troubleshooting Guide 2018 Primex. All Rights Reserved. The Primex logo is a registered trademark of Primex. All other

More information

CERAIDE FOR USE AS AN AGRICULTURAL PLANT GROWTH REGULATOR FOR PROFESSIONAL USE ONLY

CERAIDE FOR USE AS AN AGRICULTURAL PLANT GROWTH REGULATOR FOR PROFESSIONAL USE ONLY CERAIDE FOR USE AS AN AGRICULTURAL PLANT GROWTH REGULATOR FOR PROFESSIONAL USE ONLY A soluble concentrate plant growth regulator formulation (ph buffered) containing 620 g/l (54%w/w) chlormequat and metabolic

More information

Manual Dew point scanner PCE-DPT 1

Manual Dew point scanner PCE-DPT 1 PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA Tel: 410-387-7703 Fax: 410-387-7714 info@pce-americas.com www.pce-instruments.com/us www.industrial-needs.com PCE Instruments UK Ltd. Units

More information

DRAIN TRACING DYE RED E123

DRAIN TRACING DYE RED E123 DRAIN TRACING DYE RED E123 1.1 Product Identifier Product Name CAS No. EC No. DRAIN TRACING DYE RED E123 915-67-3 213-022-2 1.2. Relevant identified uses of the substance or mixture and uses advised against

More information

Digital Multi-Day Max/ Min/Current Air and Soil Temperatures Protocol

Digital Multi-Day Max/ Min/Current Air and Soil Temperatures Protocol Digital Multi-Day Max/ Min/Current Air and Soil Temperatures Protocol Purpose To record daily measurements of maximum, minimum, and current air and soil temperatures at a common site Overview One temperature

More information

Model: WT-3181PL Instruction Manual DC: Indoor/Outdoor Atomic Wall Clock. Get Started

Model: WT-3181PL Instruction Manual DC: Indoor/Outdoor Atomic Wall Clock. Get Started Model: WT-3181PL Instruction Manual DC: 041614 18 Indoor/Outdoor Atomic Wall Clock Round Battery Cover Get Started Step 1: Remove the round battery cover from the back of the clock. Step 2: Insert 1 fresh

More information

Micro Volume QuEChERS kit

Micro Volume QuEChERS kit 225-37872 Sep. 2018 Small Capacity Pretreatment Kit Micro Volume QuEChERS kit Instruction Manual Read this manual thoroughly before you use the product. Keep this manual for future reference. This page

More information

MAGMA NOTE! 21+ USER MANUAL

MAGMA NOTE! 21+ USER MANUAL 21+ MAGMA USER MANUAL NOTE! Please do not put this product away or leave it for extended periods of time with low charge because if the battery falls below 2% then it will no longer accept a charge. Thank

More information

Digital Multi-Day Soil Temperatures Protocol

Digital Multi-Day Soil Temperatures Protocol Digital Multi-Day Soil Temperatures Protocol Purpose To record daily measurements of maximum, and minimum soil temperatures at depths of 5 and 50 cm Overview A digital thermometer is used to measure current

More information

S-S35B-F

S-S35B-F Specification S-S35B-F2-285-01-2-110 RoHS SETi Customer Drawn Approval Approval 1. Description Table of Contents: 2. Mechanical Dimensions 3. Characteristics of S-S35B-F2-285-01-2 4. Characteristic Diagrams

More information

AlphaLab Gaussmeter Model VGM -- Instructions

AlphaLab Gaussmeter Model VGM -- Instructions AlphaLab Gaussmeter Model VGM -- Instructions Power: As shipped, a standard 9 volt battery is installed. Battery life is about 10 hours (25 ma drain; 6.5 volt dropout). Low battery appears when about one

More information

für for T5-Lampen fluorescent in Multi-Lamp-Technologie

für for T5-Lampen fluorescent in Multi-Lamp-Technologie Dimmbare Dimmable electronic elektronische control Vorschaltgeräte gear für for T-ampen fluorescent in Multi-amp-Technologie lamps in technology M-tec Performance characteristics Dimmable ECG in Multi-amp

More information

Operating instructions for electronics

Operating instructions for electronics Operating instructions for electronics Initial startup (m, C, 24h) Menu choice The functions of the Traveller can be checked when the battery is inserted: 1. Segment check Do all segments light up? 2.

More information

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016 APPLICATIONS Moisture monitoring of air or gas (SF6) Suitable for indoor or outdoor Industrial, medical or aerospace fields HIGHLIGHTS High voltage circuit breakers commonly used for distribution and transmission

More information

WS-7213U Wireless 433 MHz Weather Station Instruction Manual TABLE OF CONTENTS. Figure 2. Figure 1

WS-7213U Wireless 433 MHz Weather Station Instruction Manual TABLE OF CONTENTS. Figure 2. Figure 1 WS-7213U Wireless 433 MHz Weather Station Instruction Manual TABLE OF CONTENTS Topic Page Inventory of Contents 3 Additional Equipment 4 Quick Setup 5-8 Detailed Setup Guide Battery Installation 9-11 Setting

More information

To Set Time: Turn the set knob on back of the clock movement in either direction.

To Set Time: Turn the set knob on back of the clock movement in either direction. Instruction Manual Clock/Thermometer DO NOT HANG IN DIRECT SUNLIGHT! For the most accurate temperature readings choose a location that will not be exposed to direct sunlight or other heat sources. To Set

More information

SC400 Colorimeter. Silica. Photometer-System. Instruction Manual. SiO 2. Bedienungsanleitung Seite Instruction Manual Page 19 33

SC400 Colorimeter. Silica. Photometer-System. Instruction Manual. SiO 2. Bedienungsanleitung Seite Instruction Manual Page 19 33 Photometer-System SC400 Colorimeter SiO 2 Silica DE GB FR IT ES Bedienungsanleitung Seite 3 17 Instruction Manual Page 19 33 d'emploi Page 35 49 Instruction Manual Istruzioni d'uso Pagina 51 65 Instrucciones

More information

Chemical Storage Guide

Chemical Storage Guide 1 P a g e Chemical Storage Guide It is the responsibility of every occupant, owner, tenant, contractor, employee & visitor and ALL users of this facility to ensure they take all reasonably practical steps

More information

Marquette University Effective: 5/21/02 Hazard Communication Program Updated: 03/11/09 Revision No.: 1 Page: 1

Marquette University Effective: 5/21/02 Hazard Communication Program Updated: 03/11/09 Revision No.: 1 Page: 1 Marquette University Effective: 5/21/02 Hazard Communication Program Updated: 03/11/09 Revision No.: 1 Page: 1 Introduction: The Occupational Safety & Health Administration (OSHA) Hazard Communication

More information

UVTOP. Specification S-T39B-B (Formerly UVTOP250TO39BL) RoHS. Drawn Approval Approval

UVTOP. Specification S-T39B-B (Formerly UVTOP250TO39BL) RoHS. Drawn Approval Approval UVTOP Specification S-T39B-B1-255-01-1-020 (Formerly UVTOP250TO39BL) RoHS SETi Customer Drawn Approval Approval 1. Description Table of Contents: 2. Mechanical Dimensions 3. Characteristics of S-T39B-B1-255-01-1-020

More information

PRODUCT DATA. Sound Intensity Calibrator Type 3541-A. Uses and Features

PRODUCT DATA. Sound Intensity Calibrator Type 3541-A. Uses and Features PRODUCT DATA Sound Intensity Calibrator Type 3541-A Type 3541-A enables calibration of sound intensity measuring instruments by using a coupler designed especially for sound intensity calibrations. Intensity-probe

More information

15 E OWNER S MANUAL PIRATE SPYGLASS BRING EM NEAR PIRATE SPYGLASS TELESCOPE 5 W 30 W 60 W 45 W

15 E OWNER S MANUAL PIRATE SPYGLASS BRING EM NEAR PIRATE SPYGLASS TELESCOPE 5 W 30 W 60 W 45 W 3 0 15 15 E OWNER S MANUAL PIRATE SPYGLASS BRING EM NEAR PIRATE SPYGLASS TELESCOPE 5 W 60 W 30 W 45 W Zhumell customers know that there are plenty of ways to experience the world. They also understand

More information

Product Data. Brüel & Kjær B. Sound Intensity Calibrator Type 3541

Product Data. Brüel & Kjær B. Sound Intensity Calibrator Type 3541 Product Data Sound Intensity Calibrator Type 3541 USES: Sound intensity and particle velocity calibrations Sound pressure calibration Measurement of pressure-residual intensity index FEATURES: Intensity

More information

Gluten (Gliadin) Lateral Flow IIR

Gluten (Gliadin) Lateral Flow IIR V.1/May/2012 Gluten (Gliadin) Lateral Flow IIR For the quick detection of wheat protein contaminations in foods and food-processing equipments 20 Test Sticks For Laboratory Use Only Please read full descriptions

More information

OIML R 50-3 RECOMMENDATION. Edition 2014 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

OIML R 50-3 RECOMMENDATION. Edition 2014 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION INTERNATIONAL RECOMMENDATION OIML R 50-3 Edition 2014 (E) Continuous totalizing automatic weighing instruments (belt weighers). Part 3: Test report format Instruments de pesage totalisateurs continus à

More information

PHOENIX CONTACT - 04/2016. Features

PHOENIX CONTACT - 04/2016. Features Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.

More information

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements www.milwaukeeinst.com INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements www.milwaukeeinst.com 1 Instruction Manual MA881 Refractometer for Invert Sugar Measurements

More information

Dual laser + type K thermometer INFRARED THERMOMETER

Dual laser + type K thermometer INFRARED THERMOMETER Dual laser + type K thermometer INFRARED THERMOMETER Model : ATE-2509 Your purchase of this INFRARED THERMOMETER marks a step forward for you into the field of precision measurement. Although this METER

More information

VMA, HVA, 5-HIAA Urine LC-MS/MS Analysis Kit User Manual

VMA, HVA, 5-HIAA Urine LC-MS/MS Analysis Kit User Manual Page 1 / 11 VMA, HVA, 5-HIAA Urine LC-MS/MS Analysis Kit User Manual ZV-3030-0200-20 200 2-8 C Page 2 / 11 Table of Contents 1. INTENDED USE... 3 2. SUMMARY AND EXPLANATION... 3 3. TEST PRINCIPLE... 3

More information

Quick Reference. Daily Cleaning Procedures Pages 3-8 Stopping Conditions & Recovery Steps Pages 9-20

Quick Reference. Daily Cleaning Procedures Pages 3-8 Stopping Conditions & Recovery Steps Pages 9-20 Quick Reference for Daily Cleaning Procedures Pages 3-8 Stopping Conditions & Recovery Steps Pages 9-20 852 Feehanville Drive Mt. Prospect, IL 60056 Telephone: (847) 299-9550 Fax: (847) 759-3091 2009 CUMMINS-ALLISON

More information

Operating Instructions for Digital Manometer. Model: MAN-SD

Operating Instructions for Digital Manometer. Model: MAN-SD Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5

More information

Experiment: Synthesis of Aspirin

Experiment: Synthesis of Aspirin Experiment: Synthesis of Aspirin Background Aspirin, which ranks as the most widely used drug in the United States, is one of a series of salicylic acid esters that has been known since antiquity to have

More information