MOTORIZED 3-WAY VALVE APPLICATION INSTRUCTIONS FOR LOW TEMPERATURE PROTECTION KIT MODELS PB AND CF/CH

Size: px
Start display at page:

Download "MOTORIZED 3-WAY VALVE APPLICATION INSTRUCTIONS FOR LOW TEMPERATURE PROTECTION KIT MODELS PB AND CF/CH"

Transcription

1 MOTORIZED -WY VLVE PPLICTION INSTRUCTIONS FOR LOW TEMPERTURE PROTECTION KIT MODELS PB ND CF/CH 0-07 WRNING Electrical Shock Hazard-- For your safety, turn OFF electrical power supply before making any electrical connections to avoid possible electric shock hazard. Failure to do so can cause severe personal injury or death. Figure 1-1/" Motorized -Way Valve List of kit components Model PB/PF CH 0-07 Part Number Component Description / Motorized -Way Valve G White Wire (5 ft.) G Pink Wire (5 ft.) G Yellow Wire (5 ft.) Instruction Sheet WTER FLOW SYSTEM WTER WTER FLOW B MIXED WTER CUTION Valve is intended for indoor use only. B BOILER WTER WTER FLOW Valve technical data Power Supply: -6 VC or 8- VDC Max. Power Consumption: 6VC at Full Load Control Signals: Wire Point Floating Torque: 50 in.lb. or 5.6 Nm at Rated Voltage Rotation Time: 0-50 in.lb. / 0-0 Seconds Through 90 ctuator mbient Temperature: 0 F to +1 F or -18 C to +50 C Enclosure: Motor -UL recognized QMFZ Fire Rated 9-5 Gear Train - Die Cast Zinc with a Steel Base Valve Body: Forged Brass STM B8 Ball and Stem: Nickel Plated Brass End Connections: -1/" NPT Female Max. Close-Off Pressure: 0 PSIG CUTION NOTE: -B-B is noted on the valve to depict proper orientation. rrows depict flow direction. Wiring instructions 1. Locate the 18 G white (100171), pink (100175), and yellow (100170) wires provided in the kit. s indicated by Steps through 5 below, route each wire from the connection board inside the motorized -way valve ( ) to the connection board. For PB Models Only: The connection board is located inside the junction box on the back of the unit (FIG. s & B). For CF/CH Models: The connection board is located inside the control panel on the front of the unit (FIG. ). NOTE: Lift the cover on the motorized -way valve to gain access to the connection board. Pump and motor unit are designed to be supported by the inline piping only. Do not support in any other manner. When placing pump between flanges, tighten flange bolts evenly and do not tighten excessively.

2 C SCD E C N5 CN CN R R -WY VLVE BOILER ONLY T N Figure -1/" Motorized -Way Valve Diagrams (.97) HNDLE IN MOUNTED POSITION IMPORTNT NOTE: DISCONNECT POWER TO CTUTOR BEFORE DEPRESSING CLUTCH RELESE. FILURE TO DO SO MY DMGE THE DRIVE MECHNISM HNDLE IN STORGE POSITION /" NPT FEMLE THRED (.55) Figure Route wires to connection boards - Power-fin Models prior to serial # Figure B Route wires to connection boards - Power-fin Models beginning serial # CN 1 HETER 1 ENBLE TNK R R 1 CN1 THERMOSTT 5 OPEN 6 CLOSE 7 VC 8 GND 9 LOUVER 10 PROVING 11 (+) 1 Rx RS- 1 Tx PORT 1 (-) 15 SHIELD GND B 18 SHIELD GND 19 (+) 0 (-) 1 TNK SYSTEM RET 5 SYSTEM SUP 0-10V INPUT CONNECTION BORD CONNECTION BORD CONNECTION BORD CONNECTION BORD 6 7 OUTDOOR DIR/REV DIR/REV IMG CONNECTION BORD DIR # DIR # Figure Route wires to connection boards - Copper-Fin Models CN LRM CONTCTS RUN-TIME CONTCTS OPEN CLOSE COM S1 S1 S S S S S S LOUVER PROVING SW LOUVER RELY COIL TNK QUSTT S G I G - W Y VLVE CN CN TNK SHIELD B SHIELD V - BMS IN V - RTE OUT SHIELD B SHIELD CN MOD B US CSCDE R1 CN6 CN CONNECTION BORD DIR/REV DIR # CONNECTION BORD of 8 IMG0050

3 Pump sizing instructions See Table 1 for the pressure drop information at varying flows. Reference Tables and (depending on model) below for heat exchanger pressure drop information at varying flows. The boiler pump must be sized based on the boiler, flow, and head loss of your specific application. WRNING Pump must be properly sized to overcome the head loss of: (1) the boiler heat exchanger as detailed in Tables and ; () the valve as detailed in Table 1 and the equivalent feet of piping specific to each application. Table Pressure Drop -1/" -Way Valve Head Loss Flow.9 Ft/hd 95 GPM.7 Ft/hd 90 GPM.8 Ft/hd 85 GPM.8 Ft/hd 80 GPM.5 Ft/hd 75 GPM.1 Ft/hd 70 GPM 1.6 Ft/hd 65 GPM 1. Ft/hd 60 GPM 1. Ft/hd 55 GPM 1. Ft/hd 50 GPM 0.7 Ft/hd 5 GPM 0.7 Ft/hd 0 GPM 0.5 Ft/hd 5 GPM 0.5 Ft/hd 0 GPM 0. Ft/hd 5 GPM 0. Ft/hd 0 GPM Table Heat Exchanger Pressure Drop for PB Models SYSTEM TEMPERTURE RISE CHRT BTU/HR 0 F ΔT 5 F ΔT 0 F ΔT 5 F ΔT 50 F ΔT 55 F ΔT 60 F ΔT Input Output GPM Ft/hd GPM Ft/hd GPM Ft/hd GPM Ft/hd GPM Ft/hd GPM Ft/hd GPM Ft/hd 500,000 5, ,000 65, ,000, , ,00,000 1,11, ,500,000 1,75, ,700,000 1,5, * ,000,000 1,700, * * * The sterisk indicates flow rates that exceed the Maximum llowable Flow Rate of the Heat Exchanger and must not be used. Cupro-Nickel heat exchanger required at flows above 75 GPM on Models and above 90 GPM on Models Table Heat Exchanger Pressure Drop for CF/CH Models SYSTEM TEMPERTURE RISE CHRT BTU/HR 0 F ΔT 5 F ΔT 0 F ΔT 5 F ΔT 50 F ΔT 55 F ΔT 60 F ΔT Input Output GPM Ft/hd GPM Ft/hd GPM Ft/hd GPM Ft/hd GPM Ft/hd GPM Ft/hd GPM Ft/hd 99,999 9, ,000 5, ,000 55, ,000 67, ,000 81, ,60,000 1,071, ,0,000 1,, ,800,000 1,50,000 10* ,070,000 1,759, * * The sterisk indicates flow rates that exceed the Maximum llowable Flow Rate of the Heat Exchanger and must not be used. *Cupro-Nickel Heat Exchanger Required at Flows bove 55 GPM on Models 0-75 and above 90 GPM on Models of 8

4 Installation instructions Typical piping applications: 1. Install the motorized -way valve in the piping as shown in FIG s. 5 thru 8, depending on model.. Unit(s) high limit must be set at max.. Inlet and outlet connections to the boiler are shown for reference only. ctual connections may vary from those represented here. Consult the Installation and Service Manual for actual locations.. Unit(s) pump should operate only during firing periods. Figure 5 Primary/Secondary Piping of a Single Boiler - -1/" Motorized -Way Valve - Powerfin models B = MIXED WTER B = BOILER WTER = SYSTEM WTER DETIL REMOTE * NOT TO EXCEED X OR MX OF 1 PRT REMOTE * IMG0055 of 8

5 Figure 6 Primary/Secondary Piping of Multiple Boilers - -1/" Motorized -Way Valve for each appliance - Power-fin models *REMOTE REMOTE* NOT TO EXCEED X OR MX OF 1 PRT IMG0056 Figure 7 Primary/Secondary Piping of a Single Boiler - -1/" Motorized -Way Valve - Copper-Fin models B = MIXED WTER B = BOILER WTER = SYSTEM WTER DETIL REMOTE * NOT TO EXCEED X OR MX OF 1 PRT * REMOTE IMG005 5 of 8

6 Figure 8 Primary/Secondary Piping of Multiple Boilers - -1/" Motorized -Way Valve for each appliance - Copper-Fin models * REMOTE REMOTE * NOT TO EXCEED X OR MX OF 1 PRT IMG005 Startup instructions 1. When there is no call for the heat, the valve will remain at its default position of 0 where it will be closed to bypass (the running time through the 90 going from closed to bypass to fully open is 0-0 seconds).. Observe the unit when there is a call for heat.. Check to see that the valve slowly opens to the bypass water, blending with the return water to bring the inlet temperature to the boiler up to 10 F.. Monitor the valve to make sure it maintains a constant temperature and does not make dramatic jumps. 5. s the return water heats up to 10 F or above, the valve will close to the bypass. 6 of 8

7 Notes 7 of 8

8 8 of 8 Revision Notes: Revision (ECO C01815) initial release. Revision B (ECO C0) reflects the revision of FIG. 5. Revision C (ECO C06696) reflects the update of the wiring diagram in Figure on page. Revision D (ECO C111) reflects the addition of CF/CH Models and Table on page. Revision E (PCP# / CN# ) reflects the removal of the blue wire. Revision F (PCP# / CN# ) reflects an update to add the new PF. 11/17 - Printed in U.S..

CALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05

CALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05 Modulating digital controller for heating and cooling series REGI ERED SI EN ISO 00:000 Cert. n FM UNI EN ISO 00:000 Cert. n 000 0/0 G replaces dp 0/0 Function The controller can be used with three-point

More information

E8EB-N0C2B E8EB-N0B2B

E8EB-N0C2B E8EB-N0B2B Slim Sensor CSM DS_E 1 Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree

More information

INSTALLATION INSTRUCTIONS ProVantage Plow Pulley Part Number: 84526

INSTALLATION INSTRUCTIONS ProVantage Plow Pulley Part Number: 84526 ProVantage Plow Pulley Part Number: 84526 GENERAL SAFETY PRECAUTIONS Your safety, and the safety of others, is very important. To help you make informed decisions about safety, we have provided installation

More information

WARNING. INJURY HAZARD Failure to observe these instructions could lead to severe injury or death.

WARNING. INJURY HAZARD Failure to observe these instructions could lead to severe injury or death. INSTALLATION INSTRUCTIONS ATV Front Plow Mount Kit Part Number: 80031 Applications: 2007+ Honda Rancher 420 2007+ Honda Rancher ES 420 2009+ Honda Rancher AT 420 *Not compatible with 2.5ci or A2000 winches

More information

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series Amphenol Amphenol-Tuchel Electronics GmbH Circular Connectors C 09 A/B/D Series The Company Amphenol-Tuchel Electronics GmbH is a member of the USA based Amphenol Corporation. With our own global presence

More information

Purpose of Today s Presentation

Purpose of Today s Presentation Chilled Water Distribution Systems APPA Institute for Facilities Management Dallas, TX January 19, 2017 1 Purpose of Today s Presentation To provide a broad understanding of chilled water distribution

More information

3-Way Mixing and Sequencing Globe Valves, Flared (5/8 in. O.D.) with Electric, Hydraulic, and Pneumatic Actuators

3-Way Mixing and Sequencing Globe Valves, Flared (5/8 in. O.D.) with Electric, Hydraulic, and Pneumatic Actuators lectric, Hydrulic, nd Pneumtic ctutors TL 1. Select Vlve ody including P ode (Vlve Size, v Rting, Port ode) or select Vlve ssemly correct (refer to Tle 3 nd Tle 3 lso) less ctutor ode (XXX) including the

More information

INSTALLATION INSTRUCTIONS FRONT PLOW MOUNT KIT Part Number: Application: Polaris Sportsman 400, 500, 800

INSTALLATION INSTRUCTIONS FRONT PLOW MOUNT KIT Part Number: Application: Polaris Sportsman 400, 500, 800 WARN INDUSTRIES, INC. 12900 S.E. Capps Road, Clackamas, OR USA 97015-8903, 1-503-722-1200, FAX: 1-503-722-3000 Customer Service: 1-800-543-9276 Dealer Locator Service: 1-800-910-1122 International Sales/Customer

More information

AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL

AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL FILE No. A10-023-1 REVISION 1 : Mar.2012 Re-edit version.( file volume down) Contents have NOT been changed. Model name: RAS-M10PKVP-E RAS-M13PKVP-E RAS-M16PKVP-E

More information

5. DRIVE 1. SAFETY 2. PREPARATION 3. FRAME 4. TRANSMISSION 6. ROW UNIT 7. OPTIONAL EQUIPMENT

5. DRIVE 1. SAFETY 2. PREPARATION 3. FRAME 4. TRANSMISSION 6. ROW UNIT 7. OPTIONAL EQUIPMENT TABLE OF CONTENTS 1. SAFETY 2. PREPARATION 3. FRAME 4. TRANSMISSION 5. DRIVE 6. ROW UNIT 7. OPTIONAL EQUIPMENT DRIVE Standard Turbofan 540, 450 & 1000 RPM with PTO Drive Your Monosem planter will be equipped

More information

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH General information These connectors are designed and produced in conformity with the low-voltage directive (/3/EWG) respectively

More information

PLOW MOUNT KIT FOR POLARIS RANGER P/N ASSEMBLY / OWNERS MANUAL

PLOW MOUNT KIT FOR POLARIS RANGER P/N ASSEMBLY / OWNERS MANUAL PLOW MOUNT KIT FOR POLARIS RANGER P/N 34-3010 ASSEMBLY / OWNERS MANUAL Application PLOW PUSH FRAME NO. 34-0000 or 34-0070 Before you begin, please read these instructions and check to be sure all parts

More information

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components: SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine

More information

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application Type 2657...59 DN 10 up to 80 mm; Plastic; 2/2 way dvantages/benefits ntegrated pilot valves, position feed-back and limit switches available Customized system solutions with Burkert valves & sensors With

More information

ENVIRONMENTALLY SOUND R 410A REFRIGERANT

ENVIRONMENTALLY SOUND R 410A REFRIGERANT ENVIRONMENTALLY SOUND REFRIGERANT N4H3 Performance Series Product Specifications EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase,

More information

Installation guide 862 MIT / MIR

Installation guide 862 MIT / MIR Installation guide 862 MIT / MIR in combination with: 864 MTT or 863 MRT or (dual) spot element November 2005 Part no. 4416.232_Rev3 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100

More information

INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: (50 ), (54 ), or (60 ) Application: All Terrain Vehicles

INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: (50 ), (54 ), or (60 ) Application: All Terrain Vehicles INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: 78950 (50 ), 78954 (54 ), or 78960 (60 ) Application: All Terrain Vehicles Your safety, and the safety of others, is very important. To help you make

More information

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS CADB/T-N Series

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS CADB/T-N Series FILTERS F7 Compact heat recovery unit with cross-flow heat exchanger in 9 sizes from 500 m 3 /h to 8.350 m 3 /h. The casing is made from aluminium profile frame with double skinned 25 mm steel panels with

More information

MODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH

MODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH MODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH No. Part Name Quantity BOM code List Price Remark 1 Panel assembly 1 201132890609 2 Air filter 2 201132890704 5 Display box

More information

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons Series Multi-Position, Internal TXV Product Features Internal factory-installed thermal expansion valves for cooling and heat pump applications Direct drive, multi-speed ECM blower motor All-aluminum evaporator

More information

Fluid Cooling Industrial PF Series

Fluid Cooling Industrial PF Series Fluid Cooling Industrial PF Series 0916 STAINLESS STEEL PLATES CARBON STEEL FRAME Performance Notes Carry bar Gasketed plate style heat exchanger Tie rods Oil to water applications High performance Pressure

More information

50 Gordon Drive, Rockland, Maine sherplows.com. STORM BOXX Snowplow. 10' and 12' Box Plow for Backhoe Loaders

50 Gordon Drive, Rockland, Maine sherplows.com. STORM BOXX Snowplow. 10' and 12' Box Plow for Backhoe Loaders Fisher Engineering 50 Gordon Drive, Rockland, Maine 04841-2139 www.fi sherplows.com 83180, 83185 May 15, 2013 Lit. No. 43687, Rev. 00 STORM BOXX Snowplow 10' and 12' Box Plow for Backhoe Loaders Owner's

More information

PARTS MANUAL Gas Furnace F8MXN, F8MXL, G8MXN, G8MXL

PARTS MANUAL Gas Furnace F8MXN, F8MXL, G8MXN, G8MXL Gas Furnace F8MXN, F8MXL, G8MXN, G8MXL DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used to identify levels of hazard seriousness. The signal word DANGER

More information

PLOW MOUNT KIT FOR YAMAHA VIKING P/N ASSEMBLY / OWNERS MANUAL. Application PLOW PUSH FRAME NO or

PLOW MOUNT KIT FOR YAMAHA VIKING P/N ASSEMBLY / OWNERS MANUAL. Application PLOW PUSH FRAME NO or PLOW MOUNT KIT FOR YAMAHA VIKING P/N 34-5020 ASSEMBLY / OWNERS MANUAL Application PLOW PUSH FRAME NO. 34-0000 or 34-0070 Before you begin, please read these instructions and check to be sure all parts

More information

Important Instructions

Important Instructions Important Instructions Subject Use With Cabinet Hardmount Trunnion Replacement Cabinet Hardmount 8-60 Pound Washer-Extractors and Kits F77000, F7700, F7700, F7700, F7700, F7700, F9P and F9P WARNING This

More information

FOR CAN-AM ATV s P/N ASSEMBLY / OWNERS MANUAL

FOR CAN-AM ATV s P/N ASSEMBLY / OWNERS MANUAL MID-MOUNT KIT FOR CAN-AM ATV s P/N 15-7580 ASSEMBLY / OWNERS MANUAL Application PLOW PUSH FRAME NO. 15-0070, 33-0000 or 33-0070 Before you begin, please read these instructions and check to be sure all

More information

ClimateMaster s Tranquility 22. Raj Hiremath Director of Residential Marketing

ClimateMaster s Tranquility 22. Raj Hiremath Director of Residential Marketing ClimateMaster s Tranquility 22 Raj Hiremath Director of Residential Marketing 1 CLIMATEMASTER Industry leader since 1950 s First to introduce 2-stage 27 EER unit First to introduce Outdoor split system

More information

ER2 Short-head Electric Chain Hoist

ER2 Short-head Electric Chain Hoist O/M NO.SHER2-0903-CE-00 ER2 Short-head Electric Chain Hoist (250kg to 5t) Operation Manual (SHER2M/SHER2SG/SHER2SP) Introduction The KITO Short-head Electric Chain Hoist is intended for effective use in

More information

M O D U L E - 3A Model A10V0 Piston Pump Manual A10V0 PUMP. Features

M O D U L E - 3A Model A10V0 Piston Pump Manual A10V0 PUMP. Features T E C H N I C A L I N F O R M A T I O N M A N U A L F O R T H E A 1 0 V 0 V A R I A B L E D I S P L A C E M E N T P U M P S A10V0 PUMP Features High Efficiency through load sensing (= fuel savings) Maximum

More information

6/2 way directional valve type 6/2UREM6 and 6/2URMM6

6/2 way directional valve type 6/2UREM6 and 6/2URMM6 6/2 wy directionl vlve type 6/2UREM6 nd 6/2URMM6 NS6 dm 3 up to 35 MP up to 50 /min DT SHEET - OPERTION MNUL WK 421 540 03.2016 PPLICTION Moile 6 wy 2 position stckle directionl vlves type 6/2UREM6...

More information

Minute Impulse Clock Controller I01DN

Minute Impulse Clock Controller I01DN 99b-mi USER S MANUAL Minute Impulse Clock Controller Mon Jun 01, 2009 12:00:00 PM DST HOLD ENTER KEY TO BEGIN CANCEL HR I01DN 97 West Street Medfield, MA 02052 U.S.A. (508) 359-4396 Pg. 2 of 20 TABLE OF

More information

nufacturing Company, L.P San Felipe, Suite

nufacturing Company, L.P San Felipe, Suite Mini-Split Heat Pump Outdoor Unit RXS09LVJU RXS12LVJU RXS15LVJU RXS18LVJU RXS24LVJU REPAIR PARTS nufacturing Company, L.P. 5151 San Felipe, Suite 500 www.amana-hac.com www.amana-hac.com This manual is

More information

P303 Pressure Regulator

P303 Pressure Regulator P0 Pressure Regulator Minimize Sudden Downstream Load Change Wide Pressure Ranges Integral Monitoring The BelGAS P0 and P0H gas pressure reducing regulators are available with a true monitor regulator,

More information

M2 SERIES THERMOSTATS 0 F to 240 F, Narrow Differential, Hermetically Sealed ½

M2 SERIES THERMOSTATS 0 F to 240 F, Narrow Differential, Hermetically Sealed ½ M2 SERIES THERMOSTATS 0 F to 240 F, Narrow Differential, Hermetically Sealed ½ Introduction The Klixon M2 thermostat is constructed with a snap acting bimetal disc that serves as the actuating element.

More information

Amphenol Amphenol-Tuchel Electronics GmbH. C 091 A/B/D Series. Circular Connectors.

Amphenol Amphenol-Tuchel Electronics GmbH. C 091 A/B/D Series. Circular Connectors. mphenol mphenol-tuchel Electronics GmbH C 09 //D Series Circular Connectors www.industrial-amphenol.com Note from the CEO Ladies and Gentlemen, For over years mphenol has enjoyed success as the interconnection

More information

JDV CONTROL VALVES CO., LTD. JCT/JCTM Series 3/4 Way Trunnion Type Valve Manual

JDV CONTROL VALVES CO., LTD. JCT/JCTM Series 3/4 Way Trunnion Type Valve Manual JCT/JCTM Series 3/4 Way Trunnion Type Valve Manual 1. Please read this manual before installation or servicing. 2. Before installing or servicing, please ensure the line pressure has been relieved and

More information

EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz ENVIRONMENTALLY SOUND REFRIGERANT N4H3 Performance Series Product Specifications EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase,

More information

FOR POLARIS ATV s P/N ASSEMBLY / OWNERS MANUAL

FOR POLARIS ATV s P/N ASSEMBLY / OWNERS MANUAL MID-MOUNT KIT FOR POLARIS ATV s P/N 15-3591 ASSEMBLY / OWNERS MANUAL Application PLOW PUSH FRAME NO. 15-0070, 33-0000 or 33-0070 Before you begin, please read these instructions and check to be sure all

More information

INSTALLATION INSTRUCTIONS PLOW MOUNT KIT Part Number: Application: Honda Foreman 500

INSTALLATION INSTRUCTIONS PLOW MOUNT KIT Part Number: Application: Honda Foreman 500 WARN INDUSTRIES, INC. 12900 S.E. Capps Road, Clackamas, OR USA 97015-8903, 1-503-722-1200, FAX: 1-503-722-3000 Customer Service: 1-800-543-9276 Dealer Locator Service: 1-800-910-1122 International Sales/Customer

More information

Solenoid valve Types EVR 2 - EVR 40

Solenoid valve Types EVR 2 - EVR 40 Data sheet Solenoid valve s EVR 2 - EVR 40 EVR is a direct or servo operated solenoid valve for liquid, suction, and hot gas lines with HCFC and HFC refrigerants. EVR valves are supplied complete or as

More information

barmesapumps.com SELF-PRIMING CENTRIFUGAL TRASH PUMP SPECIFICATIONS Series: SH8-U Suction: 8" Discharge: 8" Spherical solids handling: 3"

barmesapumps.com SELF-PRIMING CENTRIFUGAL TRASH PUMP SPECIFICATIONS Series: SH8-U Suction: 8 Discharge: 8 Spherical solids handling: 3 SELF-PRIMING CENTRIFUGAL TRASH PUMP Series: SH-U Suction: " Discharge: " Spherical solids handling: 3" SIZE BEARING - PUMP END " x " NPT, lbs., female flange. Open single ball, radial load. LIQUID TEMPERATURE

More information

POWER PUSHER Snowplow

POWER PUSHER Snowplow May 15, 2013 Lit. No. 43682, Rev. 00 POWER PUSHER Snowplow 8' 72040; 10' 72045; Box Plow for Skid-Steer Loaders Owner's Manual and Installation Instructions Original Instructions CAUTION Read this manual

More information

Column w/laterals. Steel Column A992 50ksi Steel (see sheets 4-7)

Column w/laterals. Steel Column A992 50ksi Steel (see sheets 4-7) olumn w/ SOREOR HEIGHT WITH ddtional display area consisting signs, arches, message centers or video above or below the scoreboard. (see sheets -6) for column and pier sizing) TOP SOREOR SETION Overall

More information

Instruction. Vacuum Circuit Breaker Operator Module. Type 3AH 4.16kV to 38kV. Power Transmission & Distribution

Instruction. Vacuum Circuit Breaker Operator Module. Type 3AH 4.16kV to 38kV. Power Transmission & Distribution Instruction 0001-22-2--00 Vacuum Circuit Breaker Operator Module Type 3AH 4.16kV to 38kV Power Transmission & Distribution Hazardous voltages and high-speed moving parts. Will cause death, serious injury

More information

Product Data CNPVP, CNPVT, CNPVU, CNRVU EVAPORATOR COIL N COIL - CASED AND UNCASED UPFLOW, DOWNFLOW

Product Data CNPVP, CNPVT, CNPVU, CNRVU EVAPORATOR COIL N COIL - CASED AND UNCASED UPFLOW, DOWNFLOW CNPVP, CNPVT, CNPVU, CNRVU EVPORTOR COIL N COIL - CSED ND UNCSED UPFLOW, DOWNFLOW Product Data CNPVP CNPVT (Transition) CN(P,R)VU 06008 06007 06004 This vertical design N -coil is a furnace coil designed

More information

Lamp and Control Panel (Lamp Panel)

Lamp and Control Panel (Lamp Panel) www.reinhausen.com Lamp and Control Panel (Lamp Panel) Operating Instructions BA 47/0 EN NOTE! Changes may have been made to a product after going to press with this documentation. We expressly reserve

More information

E6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders

E6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders Multi-turn High-precision Encoder Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders Reset function for easy origin alignment when built-into equipment. Multi-turn

More information

CROSS FLOW COOLING TOWER

CROSS FLOW COOLING TOWER CROSS FLOW COOLING TOWER LUCKY GREEN THAI INDUSTRIES CO LTD Material Specification Model LGX 80 00 0 00 0 300 30 400 00 600 700 800 000 Motor Totally enclosed Totally enclosed fan cooled Driving System

More information

MODEL NAME : LLDMWW0-15K*0*A

MODEL NAME : LLDMWW0-15K*0*A Eagle Eye (Outdoor LED Module) Application Note MODEL NAME : LLDMWW0-15K*0*A RoHS Compliant HALOGEN FREE (30)-4022 1 / 16 CONTENTS 1. Product Description 3/16 2. Specifications 2.1. Chromaticity Bins for

More information

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA 300

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA 300 INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN 37850 Application: HONDA 300 Your safety, and the safety of others, is very important. To help you make informed decisions about safety, we have

More information

Peltier Application Note

Peltier Application Note Peltier Application Note Early 19th century scientists, Thomas Seebeck and Jean Peltier, first discovered the phenomena that are the basis for today s thermoelectric industry. Seebeck found that if you

More information

AIR COOLED CONDENSING UNIT

AIR COOLED CONDENSING UNIT EVOLUTION SERIES AIR COOLED CONDENSING UNIT OUTDOOR AIR COOLED CONDENSING UNIT ORIGINAL MANUFACTURED EQUIPMENT Evolution Series BA-503-3 AUS Evolution Air Cooled Condensing Unit Series Content Page Explanation

More information

16 Input AC Block I/O Module

16 Input AC Block I/O Module 6 Input AC Module Cat. No. 79-6A0 Series B Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air flow through

More information

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA MODELS: 450S AND 450ES

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA MODELS: 450S AND 450ES INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN 37852 Application: HONDA MODELS: 450S AND 450ES Your safety, and the safety of others, is very important. To help you make informed decisions about

More information

400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL

400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL 400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL FORM: MAP-TRM-E REL. July 2013 REV. 015 2013 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix AP Harmonic

More information

PARTS CATALOG. No. OBB702 REVISED EDITION-C. Models

PARTS CATALOG. No. OBB702 REVISED EDITION-C. Models Revision C: MXZ-3C24/3C30/4C36/5C42NA2 and MXZ-2C20/3C24/3C30NAHZ2 have been added. Please void OBB702 REVISED EDITION-B. OUTDOOR INDOOR UNIT UNIT PARTS CATALOG No. OBB702 REVISED EDITION-C Models MXZ-3C24NA

More information

SSi Super Systems Inc.

SSi Super Systems Inc. Model DPC2530 Continuous Digital Dew Point Analyzer For measurement of: Endothermic Atmosphere Exothermic Atmosphere Nitrogen / Hydrogen Atmosphere Plant Air Systems SPECIFICATIONS Measurement Range: -50

More information

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA 400

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA 400 INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN 37851 Application: HONDA 400 Your safety, and the safety of others, is very important. To help you make informed decisions about safety, we have

More information

METALLIZED POLYPROPYLENE AC FILTERING CAPACITORS

METALLIZED POLYPROPYLENE AC FILTERING CAPACITORS METALLIZED POLYPROPYLENE AC FILTERING CAPACITORS Technology looking ahead With the new LNF series a new level of safety for the AC capacitors has been reached: Active safety: When the capacitor is stressed

More information

Imformation of C091D series

Imformation of C091D series Imformation of C09D series The QTY of contacts is -pin to -pin, the connection method for the thread type, pinhole connections for welding type, press-fit and PCB type. This series of connectors to prevent

More information

Cartridge Valves Technical Information. Quick reference

Cartridge Valves Technical Information. Quick reference Quick reference Contents CPF0... 8. CP600-5... 8. CP60-5... 8. 066 handle kit... 8.5 MP06... 8.6 MP... 8.6 X05-FD0 Traction manifold... 8.9 X05-FD6 Traction manifold... 8.0 X05-FD0 Traction manifold...

More information

3 Port, 2-Ton Outdoor Heat Pump

3 Port, 2-Ton Outdoor Heat Pump Job Name: Tag# Submittal Data Sheet 3 Port, 2-Ton Outdoor Heat Pump 3MXS24NMVJU Efficiency SEER EER HSPF Non-Ducted 17.9 12.7 12.5 Ducted 14 9.7 8.2 Mixed 15.95 11.2 10.35 Performance Cooling (Btu/hr)

More information

/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2

/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2 / way valves (solenoid actuated diaphragm with forced lifting) /4... Damped operation Operation without differential Suitable for vacuum igh flow rate For systems with low or fluctuating Brass body Wide

More information

EXPLODED DIAGRAM - PARTS VIEW

EXPLODED DIAGRAM - PARTS VIEW Power Supply Sales Model: KSIL018-H216-I 208-230V~ / 1ph / 60Hz EXPLODED DIAGRAM - PARTS VIEW This information is to be used by qualify AC technicians only KSIL1816- Drawing No. D2IL16181301 Above information

More information

50/60 Hz. ecocirc XL and XLplus. high efficiency WET ROTOR circulators. ErP 2009/125/EC

50/60 Hz. ecocirc XL and XLplus. high efficiency WET ROTOR circulators. ErP 2009/125/EC / Hz ecocirc XL and XLplus high efficiency WET ROTOR circulators FOR COMMERCIAL HEATING AND COOLING applications ErP 9/1/EC Cod. 1971 Rev. C Ed.11/1 Lowara, ecocirc, Xylect are trademarks of Xylem Inc.

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET MAGNA, UPE Series circulator pumps Contents Product data MAGNA/UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids 3 Type key Performance

More information

Protective Coatings: Non-lead orange paint RAL red (optional) non-lead paint Hot dipped galvanized conforming to ASTM A-153.

Protective Coatings: Non-lead orange paint RAL red (optional) non-lead paint Hot dipped galvanized conforming to ASTM A-153. Technical Services: Tel: (66) 500-76 / Fax: (01) 71-7317 www.grinnell.com Grinnell Mechanical Products Grooved Fittings, Ductile Iron & Fabricated Steel General Description Grooved fittings provide an

More information

PARTS MANUAL Gas Furnace F9MAC, G9MAC

PARTS MANUAL Gas Furnace F9MAC, G9MAC Gas Furnace F9MAC, G9MAC Safety Labeling and Signal Words DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAUTION, and NOTE are used to identify levels of hazard seriousness. The signal

More information

Accumulators Virginia KMP Suction Line Accumulators

Accumulators Virginia KMP Suction Line Accumulators Accumulators Virginia KMP Suction Line Accumulators The Virginia KMP suction line accumulator's purpose is to prevent excessive quantities of liquid refrigerant and oil from returning to the compressor.

More information

CAUTION. All safety information must be followed as provided in this Technical Sheet and in Service Manual RS

CAUTION. All safety information must be followed as provided in this Technical Sheet and in Service Manual RS peed Queen Domestic asher echnical nformation 0 V, 0 Hz Models 70 70 Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit.

More information

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18 erie B. Flanged ductile iron ball valve BRanDOni made in E U R O P E Application fields WATER CONdITIONING GA EATING INdUTRY FIRE FIGTING www.brandoni.it erie B. eries B. valves are shut-off ball valves

More information

32 Input AC Block I/O Module

32 Input AC Block I/O Module Input AC Module Cat. No. 79-A0 Series B Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air to flow through

More information

GMVC8. ComfortNet -Compatible. Heating Input: 70, ,000 BTU/h. Two-Stage, Variable-Speed Gas Furnace

GMVC8. ComfortNet -Compatible. Heating Input: 70, ,000 BTU/h. Two-Stage, Variable-Speed Gas Furnace 80% AFUE Heating Input: 70,000 115,000 BTU/h ComfortNet -Compatible Two-Stage, Variable-Speed Gas Furnace Standard Features Aluminized steel, dual-diameter tubular heat exchanger Two-stage gas valve operates

More information

Features. Type List. Ordering Information TPDT H

Features. Type List. Ordering Information TPDT H SONG CHUN Features general purpose Power Relay. SPDT, DPDT, TPDT contact configurations. C & DC coils are both available. Optional for anti-rotation tab, tapped core, indicator lamp & push-to-test button,

More information

LM60B LM60C 2 7V SOT-23 Temperature Sensor

LM60B LM60C 2 7V SOT-23 Temperature Sensor LM60B LM60C 2 7V SOT-23 Temperature Sensor General Description The LM60 is a precision integrated-circuit temperature sensor that can sense a b40 C toa125 C temperature range while operating from a single

More information

FVBSS fixed volume bottle

FVBSS fixed volume bottle N FVBSS fixed volume bottle Sampling System The SENSOR Fixed Volume Bottle Sampling System (FVBSS) provides a repeatable fixed volume of sample during each sampling process without stopping flow of the

More information

Installation, Maintenance and Operating Instructions

Installation, Maintenance and Operating Instructions Trunnion-Design Ball Valves 12 20 (DN 300 500) Series 7150 12 (DN 300) Series 730S 12 20 (DN 300 500) Series 7300 14 24 (DN 350 600) Series 9150 14 24 (DN 350 600) Series 9300 Installation, Maintenance

More information

Common Lightcloud Wiring Applications. Wiring Diagrams. Overview Controller Dimmer Gateway Integrator Sensor Touch. Lightcloud

Common Lightcloud Wiring Applications. Wiring Diagrams. Overview Controller Dimmer Gateway Integrator Sensor Touch. Lightcloud Common Lightcloud Wiring Applications Wiring Diagrams Overview Dimmer Gateway Integrator Sensor Touch Lightcloud Wiring Diagrams The following diagrams are commonly used for Lightcloud installations. If

More information

VALVES. V-Series Two-way and Three-way Globe Valve Bodies, Components and Assemblies. F e a t u r e s :

VALVES. V-Series Two-way and Three-way Globe Valve Bodies, Components and Assemblies. F e a t u r e s : VALVES V-Series Two-way and Three-way Globe Valve Bodies, Components and Assemblies F e a t u r e s : Heating and cooling applications for non-corrosive fluids Steam and hot water flow control Complete

More information

PHY3901 PHY3905. Hall effect and semiconductors Laboratory protocol

PHY3901 PHY3905. Hall effect and semiconductors Laboratory protocol PHY3901 PHY3905 Hall effect and semiconductors Laboratory protocol PHY3901 PHY3905 Hall effect and semiconductors Laboratory protocol Objectives Observe and qualitatively understand the phenomenon of transverse

More information

WE RE HERE TO HELP: 1 (844) LIGHTCLOUD

WE RE HERE TO HELP: 1 (844) LIGHTCLOUD Welcome Controller LCCONTROL20/D10 WE RE HERE TO HELP: 1 (844) LIGHTCLOUD 1 (844) 544-4825 support@lightcloud.com Contents Lightcloud Controller NPT Nut O-ring Instruction Manual Wire Nuts x 4 x 2 Specifications

More information

HiPace 300 with TC 110, DN 100 CF-F

HiPace 300 with TC 110, DN 100 CF-F HiPace 300 with TC 110, DN 100 CF-F HiPace 300 with TC 110, DN 100 CF-F Rugged, powerful turbopump with a pumping speed of up to 260 l/s for N 2 Integrated TC 110 drive electronics Ideal for UHV applications

More information

LM35 Precision Centigrade Temperature Sensors

LM35 Precision Centigrade Temperature Sensors Precision Centigrade Temperature Sensors General Description Typical Applications The series are precision integrated-circuit temperature sensors, whose output voltage is linearly proportional to the Celsius

More information

Direct-operated 2/2-way solenoid valves Type EV210B

Direct-operated 2/2-way solenoid valves Type EV210B Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance

More information

SC125MS. Data Sheet and Instruction Manual. ! Warning! Salem Controls Inc. Stepper Motor Driver. Last Updated 12/14/2004

SC125MS. Data Sheet and Instruction Manual. ! Warning! Salem Controls Inc. Stepper Motor Driver.   Last Updated 12/14/2004 SC125MS Stepper Motor Driver Salem Controls Inc. Last Updated 12/14/2004! Warning! Stepper motors and drivers use high current and voltages capable of causing severe injury. Do not operate this product

More information

Edition 3 September Air Angle Wrench and Nut Runner. QA6 and QA8 Series. Parts Information. Save These Instructions

Edition 3 September Air Angle Wrench and Nut Runner. QA6 and QA8 Series. Parts Information. Save These Instructions 660072 Edition 3 September 2007 Air Angle Wrench and Nut Runner QA6 and QA8 Series Parts Information Save These Instructions Module Exploded Diagram 7 5 9 7 2 9 50 3 8 3 38 39 8 9 20 2 33 22 23 3 2 3 37

More information

BB1 & BB2 INSTALLATION & MAINTENANCE INSTRUCTIONS

BB1 & BB2 INSTALLATION & MAINTENANCE INSTRUCTIONS BB1 & BB2 INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION / IDENTIFICATION The BB series valve uses Proportion- Air closed loop technology for pressure control. It gives an output pressure proportional

More information

6/2 way directional valve. Type 6/2UREM10-1 -

6/2 way directional valve. Type 6/2UREM10-1 - 6/2 wy directionl vlve type 6/2UREM0 NS 0 dm up to 5 MP up to 80 /min DT SHEET - SERVICE MNU NUL WK 42 590.202 PPLICTION Moile 6 wy 2 position stckle directionl vlves type 6/2UREM0... re intended for hydrulic

More information

PARTS LIST E Qty. Description Alternative Price Q.ty per pck.

PARTS LIST E Qty. Description Alternative Price Q.ty per pck. Page 1 R50010327-3 MOTOP.PARTNER'96 230-240/50 110 H90 VALV.COMP.IN.1,8 X FKX E50010001-02 Qty. Alternative Price Q.ty per 007 4.008.0583 10 2 1 MOTOR FAN COVER '96 WITHOUT GRILL 0 0 008 3.099.0049 10

More information

Three-Way Mixing Valve. with or without presetting, for heating and cooling systems

Three-Way Mixing Valve. with or without presetting, for heating and cooling systems with or without presetting, for heating and cooling systems escription HEIMEIER three-way, with or without presetting, for mixing volume flows in heating and cooling systems, made of gunmetal, with protection

More information

QUANTUM CONCEPT. Swimming User s Manual

QUANTUM CONCEPT. Swimming User s Manual QUANTUM CONCEPT Swimming User s Manual 480.508.0 Version.4 Edition July 05 Documentation Updates Swiss Timing Ltd. reserves the right to make improvements in the products described in this documentation

More information

DRIFTER PLOW-IN-A-BOX

DRIFTER PLOW-IN-A-BOX DRIFTER PLOW-IN-A-BOX ASSEMBLY / OWNER S MANUAL Part No: 10-0550 OPERATING INSTRUCTIONS Congratulations! You ve just purchased one of the industry s top plow systems. The DRIFTER Plow System works great

More information

260A Tractor, Loader & Backhoe S/n & up

260A Tractor, Loader & Backhoe S/n & up International Harvester Service Manual 260A Tractor, Loader & Backhoe S/n 200501 & up Service Manual THIS IS A MANUAL PRODUCED BY JENSALES INC. WITHOUT THE AUTHORIZATION OF INTERNATIONAL HARVESTER OR IT

More information

ATV WP2 FRONT MOUNT PUSH TUBE

ATV WP2 FRONT MOUNT PUSH TUBE ATV WP2 FRONT MOUNT PUSH TUBE ASSEMBLY / OWNER S MANUAL Part No: 16-0000 MAN0352 Rev. 00 OPERATING INSTRUCTIONS Congratulations! You ve just purchased the most durable plow component in the industry. Cycle

More information

nufacturing Company, L.P San Felipe, Suite

nufacturing Company, L.P San Felipe, Suite REPAIR PARTS (2,3,4) Multi Zone Heat Pump Outdoor Unit 2MXS18GVJUAA 3MXS24JVJUAA 4MXS32GVJUAA nufacturing Company, L.P. 5151 San Felipe, Suite 500 www.amana-hac.com www.amana-hac.com This manual is to

More information

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control AIR PREPARATION ELECTRONICALLY CONTROLLED PRESSRE REGLATING ALE (PROPORTIONAL PRESSRE REGLATING ALE) SERIES control Description Abb. Port size Recommended Type Data Sheet No. flow (l/min)* airfit tecno

More information

MODE button MAX/MIN button CHANNEL button / C/ F / RCC button SNOOZE / LIGHT button Battery compartment A/C in-jack 3. 4.

MODE button MAX/MIN button CHANNEL button / C/ F / RCC button SNOOZE / LIGHT button Battery compartment A/C in-jack 3. 4. KL4912 Desktop weather station Instruction Manual Introduction This weather station comes with backlight, indoor and outdoor temperature & humidity display, and alarm clock with calendar. Fig. 1 Front

More information

SKF actuators available for quick delivery. Selection guide

SKF actuators available for quick delivery. Selection guide SKF actuators available for quick delivery Selection guide A wide range of SKF actuators available for quick delivery Industrial actuator 24 Volt DC Load range 1 000 to 4 000 N Speed range 5 to 52 mm/s

More information

Emergency lighting units EM Inverter

Emergency lighting units EM Inverter T T TC- TC-F DE TC- TC-SE TC-TE TC-DD Tc EM G, 0 0 V 0/0 Hz BASIC version Product description Emergency lighting supply unit for manual testing For linear and compact fluorescent lamps ow-profile casing

More information

Maintenance/ Discontinued

Maintenance/ Discontinued oltage Regulators N7xx/N7xxF Series 3-pin positive output voltage regulator ( type) Overview The N7xx series and the N7xxF series are 3- pin, fixed positive output type monolithic voltage regulators. Stabilized

More information