CAUTION. All safety information must be followed as provided in this Technical Sheet and in Service Manual RS

Size: px
Start display at page:

Download "CAUTION. All safety information must be followed as provided in this Technical Sheet and in Service Manual RS"

Transcription

1 peed Queen Domestic asher echnical nformation 0 V, 0 Hz Models Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit. efer to ervice Manual for detailed installation, operating, testing, troubleshooting, and disassembly instructions. efer to arts Manual 0007 for part number information.! C ll safety information must be followed as provided in this echnical heet and in ervice Manual ! o avoid risk of electrical shock, personal injury, or death, disconnect power to unit and discharge capacitor before servicing, unless Models 70 Models 70 ower ource ash cyles Voltage C 0 VC ater temperatures mperage (ingle nit) 0 ater level Variable requency 0 Hz eatures Motor horsepower / teady pin alance ystem X eceptacle -0 elf-cleaning lint filter X lug -0 elf-adjusting rear leveling legs X Dimensions 0 gitation stroke X Cabinet ri ction wash system X Height overall abric softener dispenser X Height of cabinet xtra rinse X idth 7 Motor speed speed Depth pin speed (revolutions per minute) 0 / 7 rpm Clearance washer lid 7 / gitation speed (strokes per minute) eight High 9 spm Crated 9 lbs. Medium spm ugust ev. 0

2 Component esting nformation! o avoid risk of electrical shock, personal injury, or death, disconnect power to washer before servicing, unless llustration Component est rocedure esults 000 emperature switch Disconnect wires from component to properly measure the resistance of the component. lace switch in the following positions and measure across the terminals below: Hot / Cold - > Ω arm / arm -, -, - -, -, - > Ω arm / Cold -, -, - > Ω Cold / Cold - > Ω Mixing valve Measure resistance of terminals on each valve. esistance across each valve. pproximately 000 Ω ± 0% imer Verify input and output voltage is present. ee timing sequence chart for functional description of the component. Verify wiring is correctly connected to the timer. 000 ressure switch Do not disconnect the pressure hose from pressure switch to perform measurements. Measure resistance across the following terminals on the pressure switch: erminal to erminal to efer to wiring diagram/schematic for correct contacts. ir pressure that actuates switch is determined by the water level of the tub. Continuity (no pressure) Continuity (pressure) 0000 id switch Disconnect wire terminals from switch. est terminals with switch closed. est terminals with switch open. Continuity nfinite > Ω MΩ 000 ev. 0 ugust 000

3 Component esting nformation! o avoid risk of electrical shock, personal injury, or death, disconnect power to washer before servicing, unless llustration Component est rocedure esults 0 ocker switch Measure resistance of switch (xtra inse) positions: Continuity > Ω Closed ( position) nfinite MΩ pen ( position) rake pad kit f washtub does not stop spinning within seven seconds after opening loading door. f brake pads make noises Motor ype of motor: wo speed eplace all three brake pads. pply a thin layer of silicone (9) on pads, see ervice ulletin Q ee following section nternal Motor Diagram and chematic for correct wiring contacts Drain pump Verify drain pump is not clogged or damaged. emove clog and verify proper operation. eplace drain pump if damaged. 000 ransmission assembly ype of transmission: 0 rpm xternally identical, must be identified by part number. f transmission locks-up, replace. 000 Drive belt ype of drive belt: 0 rpm efer to arts Manual, to verify which drive belt and pulley size is required. efer to arts Manual for proper pulley size. ugust ev. 0

4 nternal Motor Diagram and chematic! o avoid risk of electrical shock, personal injury, or death, disconnect power to washer before servicing, unless ne or wo peed Motors tart erminals Continuity exists between switch terminal and ed wire. Y Manually depress actuator. Continuity broken between switch terminal and ed wire. noperative start switch. eplace switch. Y Continuity exists between switch terminal and ed wire. High peed erminals Y Manually depress actuator. Continuity broken between switch terminal and ed wire. noperative high speed switch. eplace switch. Y ow peed erminals Continuity broken between switch terminal and Violet wire. Y Manually depress actuator. Continuity exists between switch terminal and Violet wire. noperative low speed switch. eplace switch. Y Motor switch checks. tart inding - ohms between rown wire and ed wire. noperative start winding. eplace motor. Y High peed inding - ohms between lue wire and Yellow wire. noperative high speed winding. eplace motor. Y ow peed inding - ohms between Yellow wire and Violet wire. noperative low speed winding. eplace motor. Y rotector Continuity exists between Yellow wire and hite wire. noperative common lead. eplace motor. Y ll motor windings checks. 000 ev. 0 ugust 000

5 nternal Motor Diagram and chematic! o avoid risk of electrical shock, personal injury, or death, disconnect power to washer before servicing, unless ire harness connection block Y hite rown Yellow lue Violet ed Y hite Yellow rown Yellow M M lue ed Violet verload protector ux. Motor ssembly (two speed motor) ugust ev. 0

6 iring Diagram and chematic! o avoid risk of electrical shock, personal injury, or death, disconnect power to washer before servicing, unless CC DM D C HD M H V H 9 Y / D / 0 D/ M. CH M M H/D Y/ / /.. 7 H/ X M /H H/ X CH 0 V CC. H D D C CC /Y /Y D /Y Y H/D 9 9 H/D Y CH / /Y D CH CM. V H/D 7 H D D M = 7 7 V H 7 CD MX VV H CD D H M 000 ev. 0 ugust 000

7 iring Diagram and chematic! o avoid risk of electrical shock, personal injury, or death, disconnect power to washer before servicing, unless CHMC 0 V.C. 0 HZ X M. CH H CD M M M CD CD CD X CH CH D CH.. M. CH H V MX VV CD H Y = CD M M H M M M 7 HH DC M ugust ev. 0

8 imer Cycle Chart! o avoid risk of electrical shock, personal injury, or death, disconnect power to washer before servicing, unless C M 0 0 D H V- V- CD -V H -H M M M- M H-M M-H, Y - X. -X - CH C M D D M CH H M H: D Y - H H M H: X M M M X DC X HD H ailure to install, maintain, and/or operate this machine according to manufacture's instructions may result in conditions which can produce bodily injury and/or property damage. H MCH MCD D M H : D :,,7;,,7;, CD :,00,; 99, H D CC CC CD. 000 X H H M M V V H Y/ / / H / 9 7 H/ 0 V H/ D 7 H/ X / 0 D/ X 9 Y D / 000 ev. 0 ugust 000

Important Instructions

Important Instructions Important Instructions Subject Use With Cabinet Hardmount Trunnion Replacement Cabinet Hardmount 8-60 Pound Washer-Extractors and Kits F77000, F7700, F7700, F7700, F7700, F7700, F9P and F9P WARNING This

More information

CHAMPION MARQUIS SPECIFICATIONS GUIDE UIDE FOR COMMERCIAL MODELS

CHAMPION MARQUIS SPECIFICATIONS GUIDE UIDE FOR COMMERCIAL MODELS I O I IO I IIIO I IIIO I O OI O IIIO I O O: / 00 / 0 / 0 / 00 / 00 / 0 / 0 / 00 // 00 V OI. OIO eavy gauge galvanized steel is used for cabinet panels and other load bearing components. Vacuumformed plastic

More information

Industrial/Commercial Evaporative Coolers Specification Guide

Industrial/Commercial Evaporative Coolers Specification Guide Industrial/ommercial vaporative oolers pecification uide IIIO I O O: / 00 / 0 / 0 / 00 / 00 / 0 / 0 / 00 // 0 V OI. OIO eavy gauge galvanized steel is used for cabinet panels and other load bearing components.

More information

TECHNICAL MANUAL 820 LX / 910 LX / 1300 LX

TECHNICAL MANUAL 820 LX / 910 LX / 1300 LX TECHNICAL MANUAL 820 LX / 910 LX / 1300 LX LANCER reserves the right to modify, constantly its documentation for its improvement. The values of adjustments indicated in the displays of this manual are

More information

Emerson Climate Technologies (India) Private Limited Karad Dhebewadi Road Karad INDIA

Emerson Climate Technologies (India) Private Limited Karad Dhebewadi Road Karad INDIA merson limate echnologies (ndia) rivate Limited MRR MDL merson limate echnologies (ndia) rivate Limited Karad Dhebewadi Road Karad - 415 110 D ote: ales compressor drawing number and compressor model name

More information

REPAIR PARTS. GMS95 Single Stage Upflow Furnace GMS950453BXAB GMS950703BXAB GMS950704CXAB GMS950904CXAB GMS951155DXAB.

REPAIR PARTS. GMS95 Single Stage Upflow Furnace GMS950453BXAB GMS950703BXAB GMS950704CXAB GMS950904CXAB GMS951155DXAB. REPAIR PARTS GMS95 Single Stage Upflow Furnace GMS950453BXAB GMS950703BXAB GMS950704CXAB GMS950904CXAB GMS55DXAB Made in the USA by: Goodman Manufacturing Company, L.P. 2550 North Loop West, Suite 400

More information

GMVC8. ComfortNet -Compatible. Heating Input: 70, ,000 BTU/h. Two-Stage, Variable-Speed Gas Furnace

GMVC8. ComfortNet -Compatible. Heating Input: 70, ,000 BTU/h. Two-Stage, Variable-Speed Gas Furnace 80% AFUE Heating Input: 70,000 115,000 BTU/h ComfortNet -Compatible Two-Stage, Variable-Speed Gas Furnace Standard Features Aluminized steel, dual-diameter tubular heat exchanger Two-stage gas valve operates

More information

Instruction. Vacuum Circuit Breaker Operator Module. Type 3AH 4.16kV to 38kV. Power Transmission & Distribution

Instruction. Vacuum Circuit Breaker Operator Module. Type 3AH 4.16kV to 38kV. Power Transmission & Distribution Instruction 0001-22-2--00 Vacuum Circuit Breaker Operator Module Type 3AH 4.16kV to 38kV Power Transmission & Distribution Hazardous voltages and high-speed moving parts. Will cause death, serious injury

More information

nufacturing Company, L.P San Felipe, Suite

nufacturing Company, L.P San Felipe, Suite REPAIR PARTS GMVC 96% ECM Up Flow Furnace GMVC960403BNAA GMVC960603BNAA GMVC960803BNAA GMVC960804CNAA GMVC961005CNAA GMVC961205DNAA nufacturing Company, L.P. 5151 San Felipe, Suite 500 www.amana-hac.com

More information

Applications SC

Applications SC AC Line Filters SC Coils, Standard ype Overview he KEME SC Coils, Standard ype AC line filters are offered in a wide variety of sizes and specifications. Applications Consumer Electronics Common mode choke

More information

REPAIR PARTS. GMEC 96% ECM Up Flow Furnace

REPAIR PARTS. GMEC 96% ECM Up Flow Furnace REPAIR PARTS GMEC 96% ECM Up Flow Furnace GMEC960302BNAA GMEC960302BNAB GMEC960402BNAA GMEC960402BNAB GMEC960603BNAA GMEC960603BNAB GMEC960803BNAA GMEC960803BNAB GMEC961004CNAA GMEC961004CNAB GMEC961205DNAA

More information

5. DRIVE 1. SAFETY 2. PREPARATION 3. FRAME 4. TRANSMISSION 6. ROW UNIT 7. OPTIONAL EQUIPMENT

5. DRIVE 1. SAFETY 2. PREPARATION 3. FRAME 4. TRANSMISSION 6. ROW UNIT 7. OPTIONAL EQUIPMENT TABLE OF CONTENTS 1. SAFETY 2. PREPARATION 3. FRAME 4. TRANSMISSION 5. DRIVE 6. ROW UNIT 7. OPTIONAL EQUIPMENT DRIVE Standard Turbofan 540, 450 & 1000 RPM with PTO Drive Your Monosem planter will be equipped

More information

Emerson Climate Technologies (India) Limited Karad Dhebewadi Road Karad INDIA

Emerson Climate Technologies (India) Limited Karad Dhebewadi Road Karad INDIA merson limate echnologies (ndia) Limited MRR MDL R53KQM-D-XXX (@ 50 Hz) BLL MRL 101, 102, 103, 201, 202, 203 ote : ales compressor drawing number and compressor model name are the same. 1 01 urrent merson

More information

Circuit Analysis and Ohm s Law

Circuit Analysis and Ohm s Law Study Unit Circuit Analysis and Ohm s Law By Robert Cecci Circuit analysis is one of the fundamental jobs of an electrician or electronics technician With the knowledge of how voltage, current, and resistance

More information

REPAIR PARTS. AVPTC Air Handler. This manual is to be used by qualified technicians only. This manual replaces RP-775E.

REPAIR PARTS. AVPTC Air Handler. This manual is to be used by qualified technicians only. This manual replaces RP-775E. REPAIR PARTS AVPTC Air Handler AVPTC24B14AA AVPTC24B14AB AVPTC24B14AC AVPTC30C14AA AVPTC30C14AB AVPTC36C14AA AVPTC36C14AB AVPTC42D14AA AVPTC42D14AB AVPTC42D14AC AVPTC48C14AA AVPTC48C14AB AVPTC48D14AA AVPTC48D14AB

More information

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product. Safety Precautions Observe the following notices to ensure personal safety or to prevent accidents. To ensure that you use this product correctly, read this User s Manual thoroughly before use. Make sure

More information

REPAIR PARTS. GDH8 80% Two-Stage Hybrid Dedicated Downflow Gas Furnace

REPAIR PARTS. GDH8 80% Two-Stage Hybrid Dedicated Downflow Gas Furnace REPAIR PARTS GDH8 80% Two-Stage Hybrid Dedicated Downflow Gas Furnace GDH80453AXAA GDH80453AXAB GDH80453AXAC GDH80703AXAA GDH80703AXAB GDH80703AXAC GDH80904BXAA GDH80904BXAB GDH80904BXAC GDH155CXAA GDH155CXAB

More information

REPAIR PARTS. AMH95 Amana brand 95% Hybrid Furnace AMH950453BXAA AMH950703BXAA AMH950704CXAA AMH950904CXAA AMH950905DXAA AMH951155DXAA

REPAIR PARTS. AMH95 Amana brand 95% Hybrid Furnace AMH950453BXAA AMH950703BXAA AMH950704CXAA AMH950904CXAA AMH950905DXAA AMH951155DXAA REPAIR PARTS AMH95 Amana brand 95% Hybrid Furnace AMH950453BXAA AMH950703BXAA AMH950704CXAA AMH950904CXAA AMH950905DXAA AMH9155DXAA Amana is a trademark of Maytag Corporation and used under license to

More information

REPAIR PARTS. GMSS 96% PSC Up Flow Furnace. This manual is to be used by qualified technicians only.

REPAIR PARTS. GMSS 96% PSC Up Flow Furnace. This manual is to be used by qualified technicians only. REPAIR PARTS GMSS 96% PSC Up Flow Furnace GMSS960402BNAA GMSS960603BNAA GMSS960803BNAA GMSS960804CNAA GMSS960805CNAA GMSS9005CNAA GMSS9205DNAA www.amana-hac.com This manual is to be used by qualified technicians

More information

REPAIR PARTS. GMVC 96% ECM Up Flow Furnace. This manual is to be used by qualified technicians only.

REPAIR PARTS. GMVC 96% ECM Up Flow Furnace. This manual is to be used by qualified technicians only. REPAIR PARTS GMVC 96% ECM Up Flow Furnace GMVC960403BNAA GMVC960603BNAA GMVC960803BNAA GMVC960804CNAA GMVC9005CNAA GMVC9205DNAA www.amana-hac.com This manual is to be used by qualified technicians only.

More information

Goodman Manufacturing Company, L.P San Felipe, Suite 500 Houston, TX 77056

Goodman Manufacturing Company, L.P San Felipe, Suite 500 Houston, TX 77056 REPAIR PARTS *CVM 96% Modulating Furnace ACVM960604CXAA ACVM960604CXBA ACVM960805DXAA ACVM960805DXBA ACVM961005DXAA GCVM960604CXAA GCVM960604CXBA GCVM960805DXAA GCVM960805DXBA GCVM961005DXAA GCVM961005DXBA

More information

REPAIR PARTS. GMEC 96% EEM Up Flow Furnace. This manual is to be used by qualified technicians only.

REPAIR PARTS. GMEC 96% EEM Up Flow Furnace. This manual is to be used by qualified technicians only. REPAIR PARTS GMEC 96% EEM Up Flow Furnace GMEC960302BNAA GMEC960402BNAA GMEC960603BNAA GMEC960803BNAA GMEC9004CNAA GMEC9205DNAA www.amana-hac.com This manual is to be used by qualified technicians only.

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer HO-NP series I P N = 4, 6, 12, 15 A Ref: HO 4-NP, HO 6-NP, HO 12-NP, HO 15-NP For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary

More information

WARNING. INJURY HAZARD Failure to observe these instructions could lead to severe injury or death.

WARNING. INJURY HAZARD Failure to observe these instructions could lead to severe injury or death. INSTALLATION INSTRUCTIONS ATV Front Plow Mount Kit Part Number: 80031 Applications: 2007+ Honda Rancher 420 2007+ Honda Rancher ES 420 2009+ Honda Rancher AT 420 *Not compatible with 2.5ci or A2000 winches

More information

PUSH TUBE STANDARD DUTY

PUSH TUBE STANDARD DUTY PUSH TUBE STANDARD DUTY ASSEMBLY / OWNER S MANUAL Part No: 15-0070 PUR223 Rev. 00 OPERATING INSTRUCTIONS Congratulations! You ve just purchased the most durable plow component in the industry. Cycle Country

More information

REPAIR PARTS. GPH14 H-SERIES R-410A Package Heat Pumps GPH1424H41AA GPH1430H41AA GPH1436H41AA GPH1442H41AA GPH1448H41AA GPH1460H41AA

REPAIR PARTS. GPH14 H-SERIES R-410A Package Heat Pumps GPH1424H41AA GPH1430H41AA GPH1436H41AA GPH1442H41AA GPH1448H41AA GPH1460H41AA REPAIR PARTS GPH14 H-SERIES R-0A Package Heat Pumps GPH1424HAA GPH1430HAA GPH1436HAA GPH1442HAA GPH1448HAA GPH1460HAA This manual is to be used by qualified technicians only. 2009 Goodman Manufacturing

More information

THIS MANUAL IS THE PROPERTY OF THE OWNER. PLEASE BE SURE TO LEAVE IT WITH THE OWNER WHEN YOU LEAVE THE JOB.

THIS MANUAL IS THE PROPERTY OF THE OWNER. PLEASE BE SURE TO LEAVE IT WITH THE OWNER WHEN YOU LEAVE THE JOB. -. September, 9 II DIMS gas-fired, power vented and separated combustion unit heaters for models HD/HDB, HDS/HD, PS/BS, P I. Fuel supply shall be shut-off and the electrical power disconnected before proceeding

More information

Melton Series. Owners Manual. Lab Centrifuge. Model # s A C, A C, B C, B C, C C, C C, D C, D C

Melton Series. Owners Manual. Lab Centrifuge. Model # s A C, A C, B C, B C, C C, C C, D C, D C Melton Series Owners Manual Lab Centrifuge Model # s A-4-115-C, A-4-220-C, B-4-115-C, B-4-220-C, C-4-115-C, C-4-220-C, D-4-115-C, D-4-220-C Serial Numbers 85500 & Above NOTICE Wire this centrifuge according

More information

Engine Immobiliser, Push-Button Start, Steering Lock, Wireless Door Lock Control, Entry & Start System (BAT) 30A ST ( 5) 40A ST ( 6) 6W B DA1 6 B W B

Engine Immobiliser, Push-Button Start, Steering Lock, Wireless Door Lock Control, Entry & Start System (BAT) 30A ST ( 5) 40A ST ( 6) 6W B DA1 6 B W B Engine Immobiliser, ush-utton Start, Steering ock, ireless Door ock Control, Entry & Start System (T) 0 ST ( ) 0 ST ( ) ST elay ( ) D C ( ) ( ) ( ) 0 ( ) ( ) C ( ) F ( ) ( ) D ( ) ( ) M C(), D(C), D(D),

More information

FOREMAN ASSEMBLY / OWNER S MANUAL

FOREMAN ASSEMBLY / OWNER S MANUAL ATV PLOW MOUNT For HONDA FOREMAN ASSEMBLY / OWNER S MANUAL Part No: 15-1610 MAN0418 Rev. 00 OPERATING INSTRUCTIONS Congratulations! You ve just purchased the most durable plow component in the industry.

More information

SC125MS. Data Sheet and Instruction Manual. ! Warning! Salem Controls Inc. Stepper Motor Driver. Last Updated 12/14/2004

SC125MS. Data Sheet and Instruction Manual. ! Warning! Salem Controls Inc. Stepper Motor Driver.   Last Updated 12/14/2004 SC125MS Stepper Motor Driver Salem Controls Inc. Last Updated 12/14/2004! Warning! Stepper motors and drivers use high current and voltages capable of causing severe injury. Do not operate this product

More information

INSTALLATION INSTRUCTIONS FRONT PLOW MOUNT KIT Part Number: Application: Polaris Sportsman 400, 500, 800

INSTALLATION INSTRUCTIONS FRONT PLOW MOUNT KIT Part Number: Application: Polaris Sportsman 400, 500, 800 WARN INDUSTRIES, INC. 12900 S.E. Capps Road, Clackamas, OR USA 97015-8903, 1-503-722-1200, FAX: 1-503-722-3000 Customer Service: 1-800-543-9276 Dealer Locator Service: 1-800-910-1122 International Sales/Customer

More information

INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: (50 ), (54 ), or (60 ) Application: All Terrain Vehicles

INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: (50 ), (54 ), or (60 ) Application: All Terrain Vehicles INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: 78950 (50 ), 78954 (54 ), or 78960 (60 ) Application: All Terrain Vehicles Your safety, and the safety of others, is very important. To help you make

More information

REPAIR PARTS. *MVC95 Variable Speed Furnace

REPAIR PARTS. *MVC95 Variable Speed Furnace *MVC95 Variable Speed Furnace AMVC950453BXBA AMVC950704CXBA AMVC950905CXBA AMVC950905DXBA AMVC9155DXBA GMVC950453BXBA GMVC950704CXBA GMVC950905CXBA GMVC950905DXBA GMVC9155DXBA REPAIR PARTS This manual

More information

DRIFTER PLOW-IN-A-BOX

DRIFTER PLOW-IN-A-BOX DRIFTER PLOW-IN-A-BOX ASSEMBLY / OWNER S MANUAL Part No: 10-0550 OPERATING INSTRUCTIONS Congratulations! You ve just purchased one of the industry s top plow systems. The DRIFTER Plow System works great

More information

ASSEMBLY / OWNER S MANUAL

ASSEMBLY / OWNER S MANUAL ATV PLOW MOUNT For Yamaha ATVs ASSEMBLY / OWNER S MANUAL Part No: 15-5590 MAN0050 Rev. 01 OPERATING INSTRUCTIONS Congratulations! You ve just purchased the most durable plow component in the industry.

More information

A.R.M. 52 PLOW With QUICK ATTACH MOUNTING SYSTEM MODEL NUMBER BLACK MODEL NUMBER GRAY. Owner s Manual

A.R.M. 52 PLOW With QUICK ATTACH MOUNTING SYSTEM MODEL NUMBER BLACK MODEL NUMBER GRAY. Owner s Manual 70 8TH AVE W PO BOX 7 SPENCER, IA 0 PHONE: 7-6-9 FAX: 7-6-08 SERVICE: 800-8- E-MAIL: ccac@cyclecountry.com www.cyclecountry.com A.R.M. PLOW With QUICK ATTACH MOUNTING SYSTEM MODEL NUMBER 0-00 BLACK MODEL

More information

nufacturing Company, L.P San Felipe, Suite

nufacturing Company, L.P San Felipe, Suite Mini-Split Heat Pump Outdoor Unit RXS09LVJU RXS12LVJU RXS15LVJU RXS18LVJU RXS24LVJU REPAIR PARTS nufacturing Company, L.P. 5151 San Felipe, Suite 500 www.amana-hac.com www.amana-hac.com This manual is

More information

REPAIR PARTS. GMV9* Variable Speed Furnace

REPAIR PARTS. GMV9* Variable Speed Furnace REPAIR PARTS GMV9* Variable Speed Furnace GMV90703BXBA GMV90905CXBA GMV155DXBA GMV950453BXBA GMV950453BXBB GMV950704CXBA GMV950704CXBB GMV950905DXBA GMV950905DXBB GMV9155DXBA GMV9155DXBB GMV9155DXBC Goodman

More information

PARTS MANUAL Gas Furnace F9MAC, G9MAC

PARTS MANUAL Gas Furnace F9MAC, G9MAC Gas Furnace F9MAC, G9MAC Safety Labeling and Signal Words DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAUTION, and NOTE are used to identify levels of hazard seriousness. The signal

More information

REPAIR PARTS. AMH95 Amana Brand 95% Hybrid Furnace

REPAIR PARTS. AMH95 Amana Brand 95% Hybrid Furnace REPAIR PARTS AMH95 Amana Brand 95% Hybrid Furnace AMH950453BXAD AMH950453BXAE AMH950703BXAE AMH950703BXAF AMH950704CXAD AMH950704CXAE AMH950904CXAE AMH950904CXAF AMH950905CXAB AMH950905DXAD AMH950905DXAE

More information

nufacturing Company, L.P San Felipe, Suite 500

nufacturing Company, L.P San Felipe, Suite 500 REPAIR PARTS AWUF Vertical Mount Air Handlers AWUF18051AA AWUF18051BA AWUF180516AA AWUF18081AA AWUF18081BA AWUF180816AA AWUF24051AA AWUF24051BA AWUF240516AA AWUF24081AA AWUF24081BA AWUF240816AA AWUF201AA

More information

ABS <2TR-FE, 5L-E>, TRC <2TR-FE, 5L-E>, VSC <2TR-FE, 5L-E>

ABS <2TR-FE, 5L-E>, TRC <2TR-FE, 5L-E>, VSC <2TR-FE, 5L-E> (I) (I) (T) (T) 0 ECU I NO. 0 S NO. 0 S NO. F F FS+ F F+ F F+ 9 I +M +S + Skid Control uzzer ssembly p p ( ) ( ) ( ) F+ p Front Speed Sensor H S S S ( ) ( ) Sq Sq 9 S P S , TC , SC

More information

AKD SYSTEM CONFIGURATION WITH KOLLMORGEN DDL LINEAR MOTORS By Kenny Hampton 1/12/2017 Rev. L

AKD SYSTEM CONFIGURATION WITH KOLLMORGEN DDL LINEAR MOTORS By Kenny Hampton 1/12/2017 Rev. L AKD SYSTEM CONFIGURATION WITH KOLLMORGEN DDL LINEAR MOTORS By Kenny Hampton 1/12/2017 Rev. L This document shows the wiring requirements for connecting the DDL linear motors to the AKD servo drive. It

More information

REPAIR PARTS. GMH95 95% Upflow Hybrid Furnace

REPAIR PARTS. GMH95 95% Upflow Hybrid Furnace REPAIR PARTS GMH95 95% Upflow Hybrid Furnace GMH950453BXAD GMH950453BXAE GMH950453BXAF GMH950703BXAE GMH950703BXAF GMH950703BXAG GMH950704CXAD GMH950704CXAE GMH950704CXAF GMH950904CXAE GMH950904CXAF GMH950904CXAG

More information

REPAIR PARTS. *MVM96 Variable Speed Furnace

REPAIR PARTS. *MVM96 Variable Speed Furnace *MVM96 Variable Speed Furnace AMVM960603BXAA AMVM960603BXBA AMVM960805CXAA AMVM960805CXBA AMVM961005DXAA AMVM961005DXBA AMVM9655DXAA AMVM9655DXBA GMVM960603BXAA GMVM960603BXBA GMVM960805CXAA GMVM960805CXBA

More information

UNIT G485 Module Capacitors PRACTICE QUESTIONS (4)

UNIT G485 Module Capacitors PRACTICE QUESTIONS (4) UNIT G485 Module 2 5.2.1 Capacitors PRACTICE QUESTIONS (4) 1 A 2200 µf capacitor is charged to a p.d. of 9.0 V and then discharged through a 100 kω resistor. (a) Calculate : (i) The initial charge stored

More information

REPAIR PARTS. GDS8 80% Furnace GDS80453AXCA GDS80453AXCB GDS80703AXCA GDS80703AXCB GDS80904BXCA GDS80904BXCB GDS81155CXCA GDS81155CXCB

REPAIR PARTS. GDS8 80% Furnace GDS80453AXCA GDS80453AXCB GDS80703AXCA GDS80703AXCB GDS80904BXCA GDS80904BXCB GDS81155CXCA GDS81155CXCB REPAIR PARTS GDS8 80% Furnace GDS80453AXCA GDS80453AXCB GDS80703AXCA GDS80703AXCB GDS80904BXCA GDS80904BXCB GDS855CXCA GDS855CXCB This manual is to be used by qualified technicians only. This manual replaces

More information

Palm Beach County Fleet Management Asset Maintenance History

Palm Beach County Fleet Management Asset Maintenance History 10172350 2009 CHEVROLET MALIBU Car, Intermediate, Hybrid Workorder 843838 Meter 0 In Date 09/05/2008 Closed 09/05/2008 Problem PRE-DELIVERY INSPECTION - Pre-delivery Inspection 2.00 Labor 120.00 Parts

More information

Number of poles 1-pole 2-pole Minimum Enclosure Contact G2R-1A-E G2R-1-E

Number of poles 1-pole 2-pole Minimum Enclosure Contact G2R-1A-E G2R-1-E The Best Seller eneral purpose power elays of single-pole0 A and double-pole A. Safety-oriented design with dielectric strength of,000 V between coil and contacts, and surge resistance of 0,000 V. and

More information

Field Pro Operation and Installation Manual

Field Pro Operation and Installation Manual Field Pro Operation and Installation Manual Xtreme Research Corporation SkyScan Division P.O. Box 336, Port Richey, FL 34673-0336 1-800-732-0665 Table of Contents 1. Installation 3 2. Operation 5 3. Care

More information

MR certified. iq Series, Ultra Low ESR, NP0. RF & Microwave Capacitors, RoHS Compliant DESCRIPTION APPLICATIONS CIRCUIT APPLICATIONS

MR certified. iq Series, Ultra Low ESR, NP0. RF & Microwave Capacitors, RoHS Compliant DESCRIPTION APPLICATIONS CIRCUIT APPLICATIONS R & Microwave Capacitors, Ro Compliant DECRIPIO owest ER in class ighest working voltage in class - 500V tandard EI sizes aser Marked (optional) igh elf Resonance requencies PPICIO Cellular ase tation

More information

nufacturing Company, L.P San Felipe, Suite

nufacturing Company, L.P San Felipe, Suite REPAIR PARTS (2,3,4) Multi Zone Heat Pump Outdoor Unit 2MXS18GVJUAA 3MXS24JVJUAA 4MXS32GVJUAA nufacturing Company, L.P. 5151 San Felipe, Suite 500 www.amana-hac.com www.amana-hac.com This manual is to

More information

AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL

AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL FILE No. A10-023-1 REVISION 1 : Mar.2012 Re-edit version.( file volume down) Contents have NOT been changed. Model name: RAS-M10PKVP-E RAS-M13PKVP-E RAS-M16PKVP-E

More information

MAINTENANCE EVALUATION CHECKLIST HYDRAULIC ELEVATORS

MAINTENANCE EVALUATION CHECKLIST HYDRAULIC ELEVATORS Manufacturer: Model: Evaluation Performed By: INTRODUCTION: This checklist will enable the user to make an objective appraisal of the condition of the equipment. Given the variety and complexity of the

More information

INSTALLATION GUIDE OWNER S GUIDE

INSTALLATION GUIDE OWNER S GUIDE INSTALLATION GUIDE OWNER S GUIDE PASSLOCK / PASSKEY SYSTEM MODEL 721 CONTENTS Technical Assistance...1 Passlock History...1 Passkey Installation...1 Passlock I Installation...2 Passlock II Installation...2

More information

OWNER'S MANUAL SERIES 3000 MODEL GTW NEMA 4

OWNER'S MANUAL SERIES 3000 MODEL GTW NEMA 4 The hamberlain Group, Inc. A DUHI ENTERPRIE Larch Avenue Elmhurst, Illinois 0 WNER' MANUAL ERIE 000 MDEL GTW NEMA GEARHEAD TRLLEY PERATR ADDENDUM REFER T MDEL GT INTALLATIN INTRUTIN UR LARGE ERVIE RGANIZATIN

More information

Table of Contents Pin-Configuration Selection Guide for HDE, HDS, & EFP

Table of Contents Pin-Configuration Selection Guide for HDE, HDS, & EFP Table of Contents -Configuration Selection Guide for HDE, HDS, & EFP Service Voltage Rating... Electrical Service Ratings... Ampacity Ratings by Contact... Electrical Service Ratings Explained... Operating

More information

REPAIR PARTS. GMS9*XA Gas Furnace

REPAIR PARTS. GMS9*XA Gas Furnace REPAIR PARTS GMS9*XA Gas Furnace GMS90453BXA P1256801F GMS90453BXA P1256807F GMS90703BXA P1256802F GMS90703BXA P1256808F GMS90904CXA P1256804F GMS90904CXA P1256809F GMS155DXA P1256806F Goodman Manufacturing

More information

Mark 55, SPA55 & PA55 Series

Mark 55, SPA55 & PA55 Series single solenoid open center single solenoid pilot closed center pilot 5 orted, 2 and 3 position, 4-way, Spool & Sleeve v: 5.5 Direct solenoid, solenoid pilot, or air pilot actuated lug-in solenoid with

More information

An Introduction to Insulation Resistance Testing

An Introduction to Insulation Resistance Testing An Introduction to Insulation Resistance Testing In a perfect world, electrical insulation would allow no current to flow through it. Unfortunately, a number of factors can over time result in the deterioration

More information

DRIFTER PLOW-IN-A-BOX ASSEMBLY / OWNER S MANUAL

DRIFTER PLOW-IN-A-BOX ASSEMBLY / OWNER S MANUAL DRIFTER PLOW-IN-A-BOX ASSEMBLY / OWNER S MANUAL Part No: 10-0550 OPERATING INSTRUCTIONS Congratulations! You ve just purchased one of the industry s top plow systems. The DRIFTER Plow System works great

More information

REPAIR PARTS. GPG14 "M" Series Residential Package Gas Units. This manual is to be used by qualified technicians only. This manual replaces RP-G3001.

REPAIR PARTS. GPG14 M Series Residential Package Gas Units. This manual is to be used by qualified technicians only. This manual replaces RP-G3001. REPAIR PARTS GPG14 "M" Series Residential Package Gas Units GPG1424040MAA GPG1424040MAB GPG1424060MAA GPG1424060MAB GPG1430040MAA GPG1430040MAB GPG1430060MAA GPG1430060MAB GPG1436040MAA GPG1436040MAB GPG1436060MAA

More information

REPAIR PARTS. ARUF Aluminum Coil Air Handler

REPAIR PARTS. ARUF Aluminum Coil Air Handler REPAIR PARTS ARUF Aluminum Coil Air Handler ARUF172916CA ARUF186CA ARUF193116CA ARUF303016CA ARUF363616CA ARUF364216CA ARUF374316CA ARUF486016CA ARUF496116CA This manual is to be used by qualified technicians

More information

REPAIR PARTS. GPH13 "H" Model Package Heat Pumps GPH1324H41AB GPH1330H41AB GPH1336H41AB GPH1342H41AB GPH1348H41BB GPH1360H41BB

REPAIR PARTS. GPH13 H Model Package Heat Pumps GPH1324H41AB GPH1330H41AB GPH1336H41AB GPH1342H41AB GPH1348H41BB GPH1360H41BB REPAIR PARTS GPH13 "H" Model Package Heat Pumps GPH1324H41AB GPH1330H41AB GPH1336H41AB GPH1342H41AB GPH1348H41BB GPH1360H41BB This manual is to be used by qualified technicians only. 2010 Goodman Manufacturing

More information

REPAIR PARTS. *CVC95 C'Flow Variable Speed Furnace ACVC950714CXBA ACVC950915DXBA GCVC950714CXBA GCVC950915DXBA

REPAIR PARTS. *CVC95 C'Flow Variable Speed Furnace ACVC950714CXBA ACVC950915DXBA GCVC950714CXBA GCVC950915DXBA *CVC95 C'Flow Variable Speed Furnace ACVC950714CXBA ACVC950915DXBA GCVC950714CXBA GCVC950915DXBA REPAIR PARTS This manual is to be used by qualified technicians only. 2012 Goodman Manufacturing Company,

More information

Alternating Current (AC): Alternating Current is electric current that reverses directions at regular intervals.

Alternating Current (AC): Alternating Current is electric current that reverses directions at regular intervals. Glossary Alternating Current (AC): Alternating Current is electric current that reverses directions at regular intervals. American National Standards Institute (ANSI): American National Standards Institute

More information

FDB1050REB2 FDB1050REC2 FDB1050REM2 FDB1050REQ2 FDB1050RES2

FDB1050REB2 FDB1050REC2 FDB1050REM2 FDB1050REQ2 FDB1050RES2 Product No. B2 C2 M2 Q2 S2 Series Built-in 24" Built-in 24" Built-in 24" Built-in 24" Built-in 24" Color black stainless silver mist bisque white Owner's Guide English 154591101 154591101 154591101 154591101

More information

Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000,

Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000, Digital Current Transducer HLSR-PW series I P N = 16... 50 A Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000, Bitstream output from on onboard Sigma Delta modulator. For the electronic measurement

More information

Simple circuits - 3 hr

Simple circuits - 3 hr Simple circuits - 3 hr Resistances in circuits Analogy of water flow and electric current An electrical circuit consists of a closed loop with a number of different elements through which electric current

More information

ATV WP2 FRONT MOUNT PUSH TUBE

ATV WP2 FRONT MOUNT PUSH TUBE ATV WP2 FRONT MOUNT PUSH TUBE ASSEMBLY / OWNER S MANUAL Part No: 16-0000 MAN0352 Rev. 00 OPERATING INSTRUCTIONS Congratulations! You ve just purchased the most durable plow component in the industry. Cycle

More information

MOTORIZED 3-WAY VALVE APPLICATION INSTRUCTIONS FOR LOW TEMPERATURE PROTECTION KIT MODELS PB AND CF/CH

MOTORIZED 3-WAY VALVE APPLICATION INSTRUCTIONS FOR LOW TEMPERATURE PROTECTION KIT MODELS PB AND CF/CH MOTORIZED -WY VLVE PPLICTION INSTRUCTIONS FOR LOW TEMPERTURE PROTECTION KIT 10017190 MODELS PB 50-001 ND CF/CH 0-07 WRNING Electrical Shock Hazard-- For your safety, turn OFF electrical power supply before

More information

Model M3484 Industrial Line Noise Filter Module Customer Reference Manual

Model M3484 Industrial Line Noise Filter Module Customer Reference Manual Model M3484 Industrial Line Noise Filter Module Customer Reference Manual Web: www.bonitron.com Tel: 615-244-2825 Email: info@bonitron.com Bonitron, Inc. Bonitron, Inc. Nashville, TN An industry leader

More information

Smaller. Performance Characteristics. 0.5C (ma) [ C : Rated Capacitance(F)] (After 30 minutes' application of rated voltage : 2.7V) ESR ESR 2 U P±0.

Smaller. Performance Characteristics. 0.5C (ma) [ C : Rated Capacitance(F)] (After 30 minutes' application of rated voltage : 2.7V) ESR ESR 2 U P±0. LCRIC DOBL LAYR CAACIOR "VerCA " Radial Lead ype, Hig Voltage series Hig voltage type (.V). uitable for quick carge and discarge. Wide temperature range ( to + C). Compliant to te RoH directive (//). maller

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer LDSR 0.3-TP/SP1 I P R N = 300 ma For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Closed

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer HO-NP/SP33 series I PN = 8, 15, 25 A Ref: HO 8-NP/SP33, HO 15-NP/SP33, HO 25-NP/SP33 For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the

More information

S Sapling INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS. advanced time and control systems

S Sapling INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS. advanced time and control systems INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS Time base: 60 Hz (3-wire system) Quartz (2-wire system) Power input: 85 135 VAC / 60 Hz 7 28 VAC / 60 Hz Current consumption:

More information

FFHT1831QE2 FFHT1831QM2 FFHT1831QP2 FFHT1831QQ2 FFHT1831QS2

FFHT1831QE2 FFHT1831QM2 FFHT1831QP2 FFHT1831QQ2 FFHT1831QS2 Product No. E2 M2 P2 Q2 S2 Series R134a R134a R134a R134a R134a Color black silver mist white bisque stainless Volts 115V 115V 115V 115V 115V Wiring Diagram A01475501 A01475501 A01475501 A01475501 A01475501

More information

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet: abc instruments international FLT5A Thermometer Land Instruments International Dronfield, S18 1DJ England Telephone: (1246) 417691 Facsimile: (1246) 41585 Email: infrared.sales@landinst.com Internet: www.landinst.com

More information

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components: SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine

More information

REPAIR PARTS. GCH95 95% Counterflow Hybrid Furnace. This manual is to be used by qualified technicians only. This manual replaces RP-597C.

REPAIR PARTS. GCH95 95% Counterflow Hybrid Furnace. This manual is to be used by qualified technicians only. This manual replaces RP-597C. REPAIR PARTS GCH95 95% Counterflow Hybrid Furnace GCH950453BXAA GCH950453BXAB GCH950453BXAD GCH950703BXAA GCH950703BXAB GCH950703BXAD GCH950704CXAA GCH950704CXAB GCH950704CXAD GCH950904CXAA GCH950904CXAB

More information

Must Read Before Installation TadPoleTM Safety and Warnings

Must Read Before Installation TadPoleTM Safety and Warnings Must Read Before Installation TadPoleTM Safety and Warnings The recommendations, requirements, rules, and instructions of your Vehicle's Roof-Top Rack System should ALWAYS be followed. The TadPole TM,

More information

REPAIR PARTS. GPH13 "M" Series Horizontal Package Heat Pumps GPH1324M41AA GPH1330M41AA GPH1336M41AA GPH1342M41AA GPH1348M41AA GPH1360M41AA

REPAIR PARTS. GPH13 M Series Horizontal Package Heat Pumps GPH1324M41AA GPH1330M41AA GPH1336M41AA GPH1342M41AA GPH1348M41AA GPH1360M41AA REPAIR PARTS GPH13 "M" Series Horizontal Package Heat Pumps GPH1324MAA GPH1330MAA GPH1336MAA GPH1342MAA GPH1348MAA GPH1360MAA This manual is to be used by qualified technicians only. 2009 Goodman Manufacturing

More information

U.S.A. inc. WORKMAN 420 II MULTIMIXER

U.S.A. inc. WORKMAN 420 II MULTIMIXER R U.S.A. inc. Model 1105858 MANUAL INSTRUCTION and PARTS LIST Manual Part. number 3210517 R00-09/2002 Machine serial N Write in the serial n of your machine here Thank-you for purchasing a Workman 420

More information

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons Series Multi-Position, Internal TXV Product Features Internal factory-installed thermal expansion valves for cooling and heat pump applications Direct drive, multi-speed ECM blower motor All-aluminum evaporator

More information

Spare parts list UC-S

Spare parts list UC-S Spare parts list UC-S Contents Water inlet and tank heating Water softener Water drain, Mediamat Cyclo Circulating pump Wash + rinse; bottom Wash + rinse; top Boiler Dosage Panelling Cover plate, electrical

More information

REPAIR PARTS. DX17VS Outdoor Inverter. This manual is to be used by qualified technicians only.

REPAIR PARTS. DX17VS Outdoor Inverter. This manual is to be used by qualified technicians only. REPAIR PARTS DX17VS Outdoor Inverter DX17VSS181AA DX17VSS241AA DX17VSS01AA DX17VSS61AA DX17VSS421AA DX17VSS481AA DX17VSS601AA This manual is to be used by qualified technicians only. 2018 5151 San Felipe

More information

Chapter 7 Direct-Current Circuits

Chapter 7 Direct-Current Circuits Chapter 7 Direct-Current Circuits 7. Introduction... 7. Electromotive Force... 7.3 Resistors in Series and in Parallel... 4 7.4 Kirchhoff s Circuit Rules... 6 7.5 Voltage-Current Measurements... 8 7.6

More information

REPAIR PARTS. A/GPG13 Package Gas Units

REPAIR PARTS. A/GPG13 Package Gas Units REPAIR PARTS A/GPG13 Package Gas Units APG1324045MBA APG1324070MBA APG1330045MBA APG1330070MBA APG1336045MBA APG1336070MBA APG1336090MBA APG1342070MBA APG1342090MBA APG1348070MBA APG1348090MBA APG13485MBA

More information

Letter STUDENT NUMBER SYSTEMS ENGINEERING. Written examination. Monday 14 November 2016

Letter STUDENT NUMBER SYSTEMS ENGINEERING. Written examination. Monday 14 November 2016 Victorian Certificate of Education 2016 SUPERVISOR TO ATTACH PROCESSING LABEL HERE Letter STUDENT NUMBER SYSTEMS ENGINEERING Written examination Monday 14 November 2016 Reading time: 9.00 am to 9.15 am

More information

TOSHIBA Field-Effect Transistor Silicon P-Channel MOS Type SSM3J117TU. Characteristic Symbol Test Condition Min Typ. Max Unit

TOSHIBA Field-Effect Transistor Silicon P-Channel MOS Type SSM3J117TU. Characteristic Symbol Test Condition Min Typ. Max Unit TOSHIBA Field-Effect Transistor Silicon P-Channel MOS Type SSMJ7TU High-Speed Switching Applications 4 V drive Low ON-resistance: R on = 225 mω (max) (@V GS = ) R on = 7 mω (max) (@V GS = V) Absolute Maximum

More information

SERVOSTAR S- and CD-Series Regeneration Requirements

SERVOSTAR S- and CD-Series Regeneration Requirements www.danaherotion.com SEROSTAR S- and CD-Series Regeneration Requirements One of the key (and often overlooked) considerations for servo system sizing is regeneration requirements. An undersized regeneration

More information

TC7WB66CFK,TC7WB66CL8X TC7WB67CFK,TC7WB67CL8X

TC7WB66CFK,TC7WB66CL8X TC7WB67CFK,TC7WB67CL8X CMOS Digital Integrated Circuits Silicon Monolithic TC7WB66CFK,TC7WB66CL8X TC7WB67CFK,TC7WB67CL8X 1. Functional Description Dual SPST Bus Switch 2. General TC7WB66CFK/L8X,TC7WB67CFK/L8X The TC7WB66CFK/L8X

More information

hydrideicp Hydride Generation System

hydrideicp Hydride Generation System HG-MP2-4-A hydrideicp Generation System hydrideicp Hydride Generation System User Manual MP 2 hydrideicp Generation System Elemental Scientific Phone: 1.402.991.7800 Email: esi@icpms.com 1500 North 24th

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer HO-NSM series I PN = 8, 15, 25 A Ref: HO 8-NSM, HO 15-NSM, HO 25-NSM For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the

More information

TA7262P,TA7262P(LB),TA7262F

TA7262P,TA7262P(LB),TA7262F TOSHIBA BIPOLAR LINEAR INTEGRATED CIRCUIT SILICON MONOLITHIC TA7262P,TA7262P(LB),TA7262F DC MOTOR DRIVER (3 PHASE Bi DIRECTIONAL) The TA7262P / P (LB) / F are 3 Phase Bi Directional supply voltage control

More information

Data Sheet. Functional Safety Characteristic Safety Values for BE..(FS) Brakes * _0715*

Data Sheet. Functional Safety Characteristic Safety Values for BE..(FS) Brakes * _0715* Drive Technology \ Drive Automation \ System Integration \ Services *22292616_0715* Data Sheet Functional Safety Characteristic Safety Values for BE..(FS) Brakes Edition 07/2015 22292616/EN SEW-EURODRIVE

More information

PHOENIX CONTACT - 04/2016. Features

PHOENIX CONTACT - 04/2016. Features Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.

More information

MSBCCL Series Asynchronous Three-Phase Brake Motors With Squirrel Cage Rotor Direct Current Brake

MSBCCL Series Asynchronous Three-Phase Brake Motors With Squirrel Cage Rotor Direct Current Brake NEMA MOTOR GOST MOTOR IEC MOTOR MSBCCL Series Asynchronous Three-Phase Motors ith Squirrel Cage Rotor Direct Current PUMP D.C. MOTOR GENERATOR MSBCCL series-enclosed construction externally ventilated-sizes

More information

Installation and Operation Manual. AllSync Plus Wired Clocks

Installation and Operation Manual. AllSync Plus Wired Clocks and Operation Manual AllSync Plus Wired Clocks Part # H004881 Rev. 4 September 2018 Safety Precautions AllSync Plus Clock & Operation Manual Troubleshooting General Operation Introduction Safety Precautions

More information