1 Quality Test Center PERiMETER: Applications Surface characterization (coarseness) Cleanliness conditions fulfilling packaging Ultra precision cleaning Porosity and damage analysis CT-based coordinate measuring instrument Size accuracy METROTOM 1500 Airborne Particle Counter LASAIR Jet Station Multi SensorTool O- INSPECT 442 Zoom Microscope Axio Zoom.V16 Particle emission Monitoring Assembling- and defect analysis Analysis of materials Automated particle analysis Correlative analysis Gravimetric analysis Inspection Scanning electron microscope EVO MA 25 Contamination Test Unit CTU 1000 Analytical Balance Technical cleanliness Particle extraction

2 Quality Test Center PERiMETER: Equipment Zeiss EVO MA25 Scanning Electron Microscope ACP JetStation CO 2 -Snow Jet Cleaning Zeiss AxioZoom.V16 Zoom Microscope Gläser RiuS Double Extraction Chamber Zeiss Metrotom 1500 CT-based Coordinate Measuring Instrument CTU 1000 Series Contamination Test Unit Zeiss O-INSPECT 442 Multi Sensor Tool Jomesa Stereomicroscope Zeiss SURFCOM FLEX 50A Mobile Control and Analysis Unit for Surfaces MicroQuick Particle Scanner Testo Probes Environmental Monitoring PMS LASAIR Aerosol Particle Counter

3 Zeiss EVO MA 25 Scanning Electron Microscope EVO MA 25 is a SEM for large and/or heavy samples high brightness LaB₆ source for X-ray analysis maximum specimen dimensions: 150mm x 150mm x 210mm (max. 5 kg) pressure range: Pa (incl. variable pressure) resolution: 3 30 kv resp kv (VP mode) detectors: BSD Multisegment Diode, VPSE Variable Pressure Secondary Electron Detector, SE Secondary Electron Detector Natural Resources study the morphology and investigate the mineralogy of natural resources analyze the chemical composition of minerals and rocks Manufacturing perform routine analysis to ensure manufactured components meet quality and durability requirements conduct automated analysis of particles to meet ISO (resp. VDA 19) standard analyze component defects and particle wear Forensics analyze criminal evidence including gunshot residue, coin forgery and toxicology Materials Research investigate and develop materials analyze material properties such as corrosion, temperature resistance and coating performance

4 Zeiss Axio Zoom.V16 Zoom Microscope for Large Fields Axio Zoom.V16 combines a 16x zoom with a high numerical aperture of It achieves a very high aperture in the medium zoom range already. Thus, very large object fields of 1.5 millimeters are no problem. Manufacturing In conjunction with an motorized microscope table, the Zeiss Axio Zoom.V16 is optimal for automated fast imaging and measurement of large surfaces. Thus, particle analysis such as required in automotive industry to assess Technical Cleanliness of components according to ISO (resp. VDA part 19) are no problem. Other Applications But of course, it can be also used for any other particulate cleanliness analysis in the semiconductor industry (wafer analysis), aerospace industry, medical devices, optics, forensic analysis (projectile cases) etc. Correlative Analysis Using a special software, the light microscope is also combined with the Scanning Electron Microscope for faster microscopic analysis

5 Zeiss METROTOM 1500 CT-based coordinate measuring instrument METROTOM 1500 was specially developed for a wide performance range to meet the different requirements encountered in internal or external measuring and qualification labs on a daily basis. parts made of plastic, ceramics or composite materials, as well as magnesium, aluminum and steel can be dimensionally measured and highly efficiently evaluated. specimen dimensions: Ø300 x 350 mm e.g. automotive parts and components, electronical components, plugs, cell phone and other plastic cases, metal cases, etc.

6 Zeiss O-INSPECT 442 Multi Sensor Tool O-INSPECT 442 is equipped with a contact sensor Measuring range [mm] X 400, Y 400, Z 200 Length measurement error, optical (1D) [μm] L/250 Length measurement error, contact (1D) [μm] L/250 O-INSPECT is the ideal solution for applications in the plastics industry, medicine and automotive technology and in precision mechanics always when a large number of components have to be measured quickly with high accuracy.

7 Zeiss SURFCOM FLEX 50A Mobile control and analysis unit for surfaces small, lightweight, flexible and mobile capture roughness, profile and waviness parameters class highest straightness accuraxa 3µm/50mm checking surface roughness specifications of parts and components, e.g. from automotive industry, medical device industry,

8 Testo Probes Environmental Monitoring System Testo 445, VAC measuring instrument Testo Standard ambient air probe (up to +70 C) Testo 545, Lux Meter (0 to Lux) Testo Vane measuring probe Testo Hot bulb probe Testo 816, Sound Level Meter (+30 to +130 db at a frequency range 31.5 Hz to 8 khz) Testo Comfort Level Probe to measure intensity of turbulence Testo Vane Anemometer (+0.6 to +40 m/s)

9 ACP JetStation CO 2 -Snow Jet Cleaning The CO 2 -Snow-Jet Cleaning technology is suitable for removing organic films and particles from surfaces. The patented process allows for a clean, environmentally-friendly, residue- and solvent-free cleaning of delicate and finely-structured surface areas. With the aid of a supersonic jacketed jet an increased cleaning performance can be achieved while at the same time reducing the CO 2 -consumption. environmentally-friendly and non-toxic cleaning is material non-dependent residue-free cleaning all kind of components out of different contamination critical branches, e.g. wafers, optical lenses, satellite parts, medical devices,

10 Extraction Chamber from small to large parts determine the surface cleanliness of automotive parts and components from small to large automotive and supplier industry transmission and engine builders mobile hydraulics manufacturers of hydraulic and lubrication systems and components CTU 1000 RiuS

11 Jomesa Stereomicroscope for automated particle analysis automated filter analysis system for technical cleanliness assessment templates according to VDA 19/ISO stereo microscope standard system, LED ring light with polarization unit, different zoom levels with fields of visions of ca. 1.5mm bis 10 mm, C-Mount color camera incl. PC interface. XY-cross table with 100 x 95 mm working range JOMESA patented, automated polarisation adjustment to detect metallic shiny particles automated All particles (without fibers) 2849 Technical Cleanliness filter analysis according to ISO (resp. VDA 19)

12 RJL MicroQuick Particle Scanner determine the number and size of particles on a membrane simple and robust system for the analysis of residual dirt particles a high resolution scanner maintenance-free instrument filter analysis, e. g. for the inspection of Technical Cleanliness

13 Particle Measuring Systems LASAIR Aerosol particle counter LASER AEROSOL PARTICLE COUNTER LASAIR-II size channels (0.1, 0.2, 0.3, 0.5, 1.0, and 5.0 µm) with a sampling rate of 1 CFM Application Cleanroom and minienvironment monitoring High-sensitivity applications Facility certification to ISO, FS, orbritish Standards Troubleshooting/mobile applications Manifold sampling (with Aerosol Manifold II) Process gas monitoring (with High Pressure Diffuser) Ultraclean zones (ISO 1 2) AEROSOL PARTICLE COUNTER LASAIR III 310B 6 size channels (0.3, 0.5, 1.0, 3.0, 5.0 and 10.0 um) with a sampling rate of 1 CFM (28.3 LPM) Application Cleanroom particle monitoring Cleanroom certification for ISO, EC GMP, or FS209E Particle counting trend analysis Statistical process control Troubleshooting particle excursions Particle Counter Manifold compatible Portable particle counting or dedicated particle monitoring

14 Vision Engineering Mantis Elite Inspection Microscope low magnification visual inspection microscope 2x, 4x, 6x and 8x quick change magnification options superior ergonomics for fatigue-free viewing and increased quality / productivity superb hand-eye co-ordination for inspection and manipulation tasks long working distance and large field of view true color, LED illumination providing up to 10,000 hours of shadow-free viewing choice of stands to suit numerous applications microscope for fast and easy inspection, e.g. after a CO 2 snow cleaning to assess the cleaning success

15 Sartorius Cubis MSA125P-100-DI Analytical Balance Readability Weighing Range Minimum sample weight acc. to USP (typical) Calibration Leveling Draft shield Display 0,01 0,1 mg g 30 mg Internal, isocal Automatic Automatic, with Ionizer High-resolution color TFT, touch screen

Fundamentals of Particle Counting

Fundamentals of Particle Counting Fundamentals of Particle Counting 1 Particle Counting: Remains the most significant technique for determining the cleanliness level of a fluid Useful as a tool for qualification and monitoring cleanroom

More information

Approval Block. Prepared by: Signature Date Evan Parnell 08 NOV Reviewed by: Signature Date. Approved by: Signature Date

Approval Block. Prepared by: Signature Date Evan Parnell 08 NOV Reviewed by: Signature Date. Approved by: Signature Date ATS-SOI-3660 Page: 1 of 6 Approval Block Prepared by: Signature Date Evan Parnell 08 NOV 2013 Reviewed by: Signature Date Brian Flynn 08 NOV 2013 Approved by: Signature Date Kristal Jewell 08 NOV 2013

More information

Recent Advances and Challenges in Nanoparticle Monitoring for the Semiconductor Industry. December 12, 2013

Recent Advances and Challenges in Nanoparticle Monitoring for the Semiconductor Industry. December 12, 2013 Recent Advances and Challenges in Nanoparticle Monitoring for the Semiconductor Industry December 12, 2013 Agenda Introduction Wafer Environment Nano-Contamination Requirements State-of-the-Art Monitoring

More information

PHI. Scanning XPS Microprobe

PHI. Scanning XPS Microprobe PHI Scanning XPS Microprobe Unique Scanning XPS Microprobe X-ray photoelectron spectroscopy (XPS/ESA) is the most widely used surface analysis technique and has many well established industrial and research

More information

THIN FILMS FOR PHOTOVOLTAICS AND OTHER APPLICATIONS. BY Dr.A.K.SAXENA PHOTONICS DIVISION INDIAN INSTITUTE OF ASTROPHYSICS

THIN FILMS FOR PHOTOVOLTAICS AND OTHER APPLICATIONS. BY Dr.A.K.SAXENA PHOTONICS DIVISION INDIAN INSTITUTE OF ASTROPHYSICS THIN FILMS FOR PHOTOVOLTAICS AND OTHER APPLICATIONS BY Dr.A.K.SAXENA PHOTONICS DIVISION INDIAN INSTITUTE OF ASTROPHYSICS BACKGROUND 2.8 meter coating plant at VBO, Kavalur 1.5 meter coating plant at VBO,

More information

473-SHX Dew Point Mirror

473-SHX Dew Point Mirror Humidity and Temperature Reference Hygrometer For Temperature up to 125 C Precise and stable chilled mirror dew point mirror technology High temperature optical components High temperature sample fan Cable

More information

A DIVISION OF ULVAC-PHI. Quantera II. Scanning XPS Microprobe

A DIVISION OF ULVAC-PHI. Quantera II. Scanning XPS Microprobe A DIVISION OF ULVAC-PHI Quantera II Scanning XPS Microprobe X-ray Photoelectron Spectroscopy (XPS/ESCA) is the most widely used surface analysis technique and has many well established industrial and

More information

MEMS Metrology. Prof. Tianhong Cui ME 8254

MEMS Metrology. Prof. Tianhong Cui ME 8254 MEMS Metrology Prof. Tianhong Cui ME 8254 What is metrology? Metrology It is the science of weights and measures Refers primarily to the measurements of length, weight, time, etc. Mensuration- A branch

More information

Chapter 10. Nanometrology. Oxford University Press All rights reserved.

Chapter 10. Nanometrology. Oxford University Press All rights reserved. Chapter 10 Nanometrology Oxford University Press 2013. All rights reserved. 1 Introduction Nanometrology is the science of measurement at the nanoscale level. Figure illustrates where nanoscale stands

More information

The Game-Changer in Microscopy and Microanalysis

The Game-Changer in Microscopy and Microanalysis Personal SEM (PSEM) express : The Game-Changer in Microscopy and Microanalysis Timothy J. Drake, Ph.D. Application Specialist ASPEX Corporation July 2009 ASPEX CORPORATION 175 SHEFFIELD DRIVE DELMONT,

More information

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials Thermo Scientific ICP-MS solutions for the semiconductor industry Maximize wafer yields with ultralow elemental detection in chemicals and materials Trace impurity analysis in chemicals an used in the

More information

The solution for all of your

The solution for all of your The solution for all of your nanoparticle sizing and zeta potential needs. DelsaNano Series Blood Banking Capillary Electrophoresis Cell Analysis Centrifugation Genomics Lab Automation Lab Tools Particle

More information

HOW ADVANCED PYROMETERS INCREASE THERMAL PROCESS REPEATABILITY AND PRODUCT QUALITY

HOW ADVANCED PYROMETERS INCREASE THERMAL PROCESS REPEATABILITY AND PRODUCT QUALITY HOW ADVANCED PYROMETERS INCREASE THERMAL PROCESS REPEATABILITY AND PRODUCT QUALITY Accurate temperature measurement is key for controlling the stability and repeatability of many temperature-critical processes.

More information

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect Microscanner D-Series The Only Certified Accurate Surface Instruments in the World A MUST FOR ISO 9001 ISO 9002 ISO 9003 TRACEABILITY PROGRAMS Common Surface Measurement Errors D501 and D501-RS Microscanner

More information

473 Dew Point Hygrometer

473 Dew Point Hygrometer High Performance Chilled Mirror Hygrometer With Cable Mounted Measuring Heads Highly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct

More information

PHI 5000 Versaprobe-II Focus X-ray Photo-electron Spectroscopy

PHI 5000 Versaprobe-II Focus X-ray Photo-electron Spectroscopy PHI 5000 Versaprobe-II Focus X-ray Photo-electron Spectroscopy The very basic theory of XPS XPS theroy Surface Analysis Ultra High Vacuum (UHV) XPS Theory XPS = X-ray Photo-electron Spectroscopy X-ray

More information

Remain Calm, Target Accurately

Remain Calm, Target Accurately Carl Zeiss Optronics Remain Calm, Target Accurately Telescopic Sights 3 12 x 56; 3 12 x 56 FF 4 16 x 56; 4 16 x 56 FF We make it visible. Waiting must not influence precise targeting Snipers in special

More information

Use of light microscope and stereomicroscope: measuring microscopic

Use of light microscope and stereomicroscope: measuring microscopic Experiment 1 Use of light microscope and stereomicroscope: measuring microscopic objects 1.1 Introduction The microscope is a major tool used by biologists, which was invented about 350 years ago. It is

More information

Traceability research activities in the field of airborne particle number/ mass concentration measurement Liu Junjie, Zhang Wenge, Song Xiaoping

Traceability research activities in the field of airborne particle number/ mass concentration measurement Liu Junjie, Zhang Wenge, Song Xiaoping Traceability research activities in the field of airborne particle number/ mass concentration measurement Liu Junjie, Zhang Wenge, Song Xiaoping Division of Nano metrology and Materials Measurement National

More information

In recent decades, oil analysis laboratories have used

In recent decades, oil analysis laboratories have used Analyze dirt with precision Automated scanning electron microscopy of particles in lubricants can help you zero in on root causes By William R. Herguth and Guy Nadeau In recent decades, oil analysis laboratories

More information

ONYX -MCE MULTI-CHANNEL OPTICAL FIBER PYROMETERS WITH ACTIVE EMISSIVITY COMPENSATION PRECISION TEMPERATURE MEASUREMENT FOR DEMANDING INDUSTRIAL

ONYX -MCE MULTI-CHANNEL OPTICAL FIBER PYROMETERS WITH ACTIVE EMISSIVITY COMPENSATION PRECISION TEMPERATURE MEASUREMENT FOR DEMANDING INDUSTRIAL ONYX -MCE MULTI-CHANNEL OPTICAL FIBER PYROMETERS WITH ACTIVE EMISSIVITY COMPENSATION PRECISION TEMPERATURE MEASUREMENT FOR DEMANDING INDUSTRIAL APPLICATIONS Accurate, repeatable, and reliable temperature

More information

473 Dew Point Hygrometer

473 Dew Point Hygrometer gh Performance Chilled Hygrometer With Cable Mounted Measuring Heads ghly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct insertion

More information

EM-30AX is very good space utilization

EM-30AX is very good space utilization EM helps to grasp material characteristics through providing precise images. EM makes it possible to analyze deep submicron or nanometer structure. Alteration of material caused by pressure, heat can be

More information

Chapter 12. Nanometrology. Oxford University Press All rights reserved.

Chapter 12. Nanometrology. Oxford University Press All rights reserved. Chapter 12 Nanometrology Introduction Nanometrology is the science of measurement at the nanoscale level. Figure illustrates where nanoscale stands in relation to a meter and sub divisions of meter. Nanometrology

More information

Pharmaceutical Particulate Matter

Pharmaceutical Particulate Matter Pharmaceutical Particulate Matter Analysis and Control Thomas A. Barber Baxter Healthcare Illustrations by John G. Williams Photomicrography Section by Damian S. Neuberger Interpharm Press Buffalo Grove,

More information

One-hand ph/temperature measuring instrument

One-hand ph/temperature measuring instrument One-hand ph/temperature measuring instrument testo 205 ph tip embedded in breakage-proof plastic ph Combined penetration tip with temperature probe Maintenance-free gel electrolyte C Measurement tip exchangeable

More information

BINOCULAR STEREOSCOPIC MICROSCOPE MBS-10. User Manual

BINOCULAR STEREOSCOPIC MICROSCOPE MBS-10. User Manual BINOCULAR STEREOSCOPIC MICROSCOPE MBS-10 User Manual ATTENTION! Мicroscope design may differ somewhat from description in this manual. 2 1 - PURPOSE The MBS-10 microscope is intended for observing both

More information

Meteorological Service

Meteorological Service Meteorological Service The Meteorological Service in Oman was established in 1973. Oman joined ICAO in 1973 Oman joined WMO in 1975. Meteorological Service is under the framework of the Directorate General

More information

Wiper Gold Edition. Premium Wipe Test Counter. Setting the bar higher

Wiper Gold Edition. Premium Wipe Test Counter. Setting the bar higher Wiper Gold Edition Premium Wipe Test Counter This product is available through: JRT Associates 5 Nepperhan Avenue, Suite 2B Elmsford, NY 10523 800-221-0111 Setting the bar higher Software - Simplicity,

More information

Kavli Workshop for Journalists. June 13th, CNF Cleanroom Activities

Kavli Workshop for Journalists. June 13th, CNF Cleanroom Activities Kavli Workshop for Journalists June 13th, 2007 CNF Cleanroom Activities Seeing nm-sized Objects with an SEM Lab experience: Scanning Electron Microscopy Equipment: Zeiss Supra 55VP Scanning electron microscopes

More information

Intuitive air velocity and IAQ.

Intuitive air velocity and IAQ. Intuitive air velocity and IAQ. The new combines versatility and maximum convenience. 1 The new air velocity & IAQ measuring instrument: versatility in a compact format. Welcome to a new era: the new combines

More information

DDefense. MMetals. Marie C. Vicéns

DDefense. MMetals. Marie C. Vicéns Foreign Particle Size Distribution and Characterization in Pharmaceutical Drug Products Using a High Throughput Electron Beam Analyzer Marie C. Vicéns mvicens@aspexcorp.com 1 F Forensics 2 Ia Industrial

More information

Thermal Resistance Measurement

Thermal Resistance Measurement Optotherm, Inc. 2591 Wexford-Bayne Rd Suite 304 Sewickley, PA 15143 USA phone +1 (724) 940-7600 fax +1 (724) 940-7611 www.optotherm.com Optotherm Sentris/Micro Application Note Thermal Resistance Measurement

More information

Your partner in Science!

Your partner in Science! Your partner in Science! Your partner in Science! Laser Diffraction Particle Size Distribution Analyzer LA-960 Simple, Powerful, Reliable 10 nm - 5 mm The LA-960 features intuitive software, unique accessories,

More information

Air velocity & IAQ measuring instruments

Air velocity & IAQ measuring instruments Data sheet dp Air velocity & IAQ measuring instruments - air velocity & IAQ measuring instrument - dp air velocity & IAQ measuring instrument incl. differential pressure C CO Intuitive: clearly structured

More information

integrating-sphere-construction-kits

integrating-sphere-construction-kits MODULAR INTEGRATING SPHERE CONCEPT Individually configurable integrating spheres - Made simple with the UM construction kit system from Gigahertz-Optik GmbH https://www.gigahertz-optik.de/en-a/products/cat/

More information

Automatic titrators, TitroMatic

Automatic titrators, TitroMatic 112 TitroMatic These are the fourth generation of CRISON titrators. CRISON has over 25 years experience in this field and knows that, for certain applications, the performance and cost of large titrator

More information

Multi-element process analyzer

Multi-element process analyzer Multi-element process analyzer Elemental analysis by X-ray fluorescence Compact multi-element process analyzer for liquid streams or f ixed position web applications Featuring advanced third generation

More information

Air velocity & IAQ measuring instruments

Air velocity & IAQ measuring instruments Data sheet dp Air velocity & IAQ measuring instruments - air velocity & IAQ measuring instrument - dp air velocity & IAQ measuring instrument incl. differential pressure C CO Intuitive: clearly structured

More information

PARTICLE MEASUREMENT IN CLEAN ROOM TECHNOLOGY

PARTICLE MEASUREMENT IN CLEAN ROOM TECHNOLOGY WHITEPAPER ENGLISH PARTICLE MEASUREMENT IN CLEAN ROOM TECHNOLOGY PARTICLE MEASUREMENT Particle measurement in cleanrooms. WP1508006-0100-EN, V1R0, 2015-08 PARTICLE MEASUREMENT IN CLEAN ROOM TECHNOLOGY

More information

Wiper Gold Edition. Premium Wipe Test Counter. Setting the bar higher

Wiper Gold Edition. Premium Wipe Test Counter. Setting the bar higher Wiper Gold Edition Premium Wipe Test Counter Setting the bar higher Software - Simplicity, Re-defined Load your wipe into the well and press the button. Your wipe is counted and automatically converted

More information

A DIVISION OF ULVAC-PHI

A DIVISION OF ULVAC-PHI A DIVISION OF ULVAC-PHI X-ray photoelectron spectroscopy (XPS/ESCA) is the most widely used surface analysis technique and has many well established industrial and research applications. XPS provides

More information

Coordinate Measuring Machines Coordinate INDEX Measuring Machines Coordinate Measuring Machines New Products

Coordinate Measuring Machines Coordinate INDEX Measuring Machines Coordinate Measuring Machines New Products Coordinate Measuring Machines Coordinate Measuring Machines New Products INDEX Coordinate Measuring Machines Crysta-Apex Series L-2, 3 LEGEX Series L-4 Bright-STRATO Series L-5, 6 CP Series L-6 CARBstrato

More information

ALPHA. Innovation with Integrity. The very compact and smart FTIR spectrometer FTIR

ALPHA. Innovation with Integrity. The very compact and smart FTIR spectrometer FTIR ALPHA The very compact and smart FTIR spectrometer Innovation with Integrity FTIR ALPHA FTIR Spectrometer More than just small analyze The ALPHA is more than just a compact FTIR spectrometer: Its modular

More information

The new 11-R (one part of the Mini WRAS) and GRIMM MINI-WRAS Andreas Jaksch. Symposium Stockholm Mai

The new 11-R (one part of the Mini WRAS) and GRIMM MINI-WRAS Andreas Jaksch. Symposium Stockholm Mai The new 11-R (one part of the Mini WRAS) and GRIMM MINI-WRAS Andreas Jaksch Symposium Stockholm Mai 2014 1 Outline Optical Particle Detection Method 11-R Main features of the GRIMM 11-R Measurement principle

More information

2. OPERATIONAL CONDITIONS

2. OPERATIONAL CONDITIONS 1. INTRODUCTION This device was designed for modern physics labs of colleges and graduate schools. It demonstrates the influence of a magnetic field on light, known as Zeeman Effect, and reveals the behavior

More information

The RX-6000 Sulfur in Oil Analyzer For the analysis of Sulfur in Oil and other elements from S to U

The RX-6000 Sulfur in Oil Analyzer For the analysis of Sulfur in Oil and other elements from S to U Oxford House, 20 Oxford St Newbury, Berkshire. RG14 1JB UK. sales@spectrolab.eu sales@spectrolab.co.uk Offices in UK, EU, Greece, Dubai The RX-6000 Sulfur in Oil Analyzer For the analysis of Sulfur in

More information

C N C M A C H I N I N G

C N C M A C H I N I N G C N C M A C H I N I N G C N C M A C H I N I N G P R E C I S I O N M E C H A N I C S Our machines are located in a 10,000 sqm plant and feature a wide range of machining varieties and services. Cutting-edge

More information

DYNAMIC VAPOR SORPTION ANALYZER FULLY AUTOMATED COMPACT BENCH-TOP DVS ANALYZER, FOR FAST AND ACCURATE SORPTION MEASUREMENTS.

DYNAMIC VAPOR SORPTION ANALYZER FULLY AUTOMATED COMPACT BENCH-TOP DVS ANALYZER, FOR FAST AND ACCURATE SORPTION MEASUREMENTS. DYNAMIC VAPOR SORPTION ANALYZER FULLY AUTOMATED COMPACT BENCH-TOP DVS ANALYZER, FOR FAST AND ACCURATE SORPTION MEASUREMENTS. www.hidenisochema.com The IGAsorp is a fully automated compact bench-top DVS

More information

Introduction to Fourier Transform Infrared Spectroscopy

Introduction to Fourier Transform Infrared Spectroscopy molecular spectroscopy Introduction to Fourier Transform Infrared Spectroscopy Part of Thermo Fisher Scientific Introduction What is FT-IR? FT-IR stands for Fourier Transform InfraRed, the preferred method

More information

Model 2300XP PSL & Process-Particle Wafer Deposition System

Model 2300XP PSL & Process-Particle Wafer Deposition System Model 2300XP PSL & Process-Particle Wafer Deposition System Deposit PSL spheres on wafers to create NISTtraceable PSL size standards for - calibrating wafer inspection systems - providing fab-wide and

More information

Direct reading aerosol monitors

Direct reading aerosol monitors Health and Safety Executive Direct reading aerosol monitors 27 th June 2018 Andrew Thorpe Introduction Direct reading Aerosol Monitors (DRAMs) are often used as a complementary approach to conventional

More information

Laboratory ID. Laboratory Name. Address. Phone. Lab Manager/Supervisor. QA Officer. Analyst(s) Auditor. Date(s) of Audit

Laboratory ID. Laboratory Name. Address. Phone. Lab Manager/Supervisor. QA Officer. Analyst(s) Auditor. Date(s) of Audit Method(s): Laboratory ID Laboratory Name Address Phone Lab Manager/Supervisor QA Officer Analyst(s) Auditor Date(s) of Audit NEW JERSEY DEPARTMENT OF ENVIRONMENTAL PROTECTION OFFICE OF QUALITY ASSURANCE

More information

User Manual. Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio. Model with NIST-Traceable Calibration

User Manual. Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio. Model with NIST-Traceable Calibration User Manual Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio with NIST-Traceable Calibration Model 20250-09 THE STANDARD IN PRECISION MEASUREMENT Introduction The Digi-Sense

More information

Height Master Page 343. Check Master Page 347. Calibration Tools Page 352

Height Master Page 343. Check Master Page 347. Calibration Tools Page 352 Calibration Instruments Height Master Page 343 Check Master Page 347 Calibration Tools Page 352 342 Digital Height Master Functions ZERO/ABS DATA/HOLD Auto Power OFF after 20 min. non use Low voltage alarm

More information

The Elzone II Particle Count and Size Analyzer

The Elzone II Particle Count and Size Analyzer The Elzone II 5390 Particle Count and Size Analyzer Elzone II Overview of Basic Theory Operates using the Electrical Sensing Zone (ESZ) Principle, also known as the Coulter Principle. First commercially

More information

MRI Flocculation. MRI Flocculation Systems. Mix & Match for Maximum Pretreatment Control

MRI Flocculation. MRI Flocculation Systems. Mix & Match for Maximum Pretreatment Control MRI Flocculation MRI Flocculation Systems Mix & Match for Maximum Pretreatment Control MRI Flocculation P resenting MRI m a n u f a c t u r e s v e r t i c a l t u r b i n e s (s h o w n ), h o r i z o

More information

Stick-Style Water-Resistant Infrared Thermometer for Foodservice Applications with 4:1 Distance-to-Sight Ratio Model

Stick-Style Water-Resistant Infrared Thermometer for Foodservice Applications with 4:1 Distance-to-Sight Ratio Model Stick-Style Water-Resistant Infrared Thermometer for Foodservice Applications with 4:1 Distance-to-Sight Ratio Model 35625-15 THE STANDARD IN PRECISION MEASUREMENT 1 DGMAN_35625-15_(ENG_FR).indd 1 7/8/2014

More information

PTG-NIR Powder Characterisation System (not yet released for selling to end users)

PTG-NIR Powder Characterisation System (not yet released for selling to end users) Powder Characterisation System - PTG-NIR PTG-NIR Powder Characterisation System (not yet released for selling to end users) The PTG-NIR automatic powder and granule inspection system with integrated NIR

More information

Clean Corona Ionization Technology. Peter Gefter Simco-Ion phone: (1)

Clean Corona Ionization Technology. Peter Gefter Simco-Ion phone: (1) Clean Corona Ionization Technology Peter Gefter Simco-Ion phone: (1) 510-217-0614 email: pgefter@simco-ion.com Jack Menear Jack Menear Associates phone: (1) 831-462-9338 email: jack.menear@gmail.com) Abstract

More information

High Accuracy High Speed in Your Process

High Accuracy High Speed in Your Process DX-Series Handheld Precision IR Thermometers EXERGEN C O R P O R A T I O N The Only Certified Accurate NIST Traceable Infrared Temperature Instruments in the World* High Accuracy High Speed in Your Process

More information

Elemental analysis by X-ray f luorescence. High performance EDXRF elemental analyzer

Elemental analysis by X-ray f luorescence. High performance EDXRF elemental analyzer Elemental analysis by X-ray f luorescence High performance EDXRF elemental analyzer Simple elemental analysis 1. Prepare samples No digestion; minimal sample preparation. Direct non-destructive measurement

More information

2d-Laser Cantilever Anemometer

2d-Laser Cantilever Anemometer 2d-Laser Cantilever Anemometer Introduction Measuring principle Calibration Design Comparative measurement Contact: Jaroslaw Puczylowski University of Oldenburg jaroslaw.puczylowski@forwind.de Introduction

More information

Low Temperature Physics Measurement Systems

Low Temperature Physics Measurement Systems PAGE 6 & 2008 2007 PRODUCT CATALOG Accelerate your Semiconductor Research & Developments towards Nanoscale Products. Experience your new working horse in the emerging field of semiconductor research for

More information

Electronics Supplementary Information for. Manab Kundu, Cheuk Chi Albert Ng, Dmitri Y. Petrovykh and Lifeng Liu*

Electronics Supplementary Information for. Manab Kundu, Cheuk Chi Albert Ng, Dmitri Y. Petrovykh and Lifeng Liu* Electronics Supplementary Information for Nickel foam supported mesoporous MnO 2 nanosheet arrays with superior lithium storage performance Manab Kundu, Cheuk Chi Albert Ng, Dmitri Y. Petrovykh and Lifeng

More information

Model : JEOL JSM 7610f

Model : JEOL JSM 7610f Name Field Emission Electron Scanning Microscopy (FESEM) Make: JEOL India Pvt Ltd. Model : JEOL JSM 7610f Specification Electron gun : Schottky type field emission (T-FE) gun Electron Beam resolution (secondary

More information

New advances in folded pathlength technology for Process Tunable Diode Laser Absorption Spectrometers (TDLAS)

New advances in folded pathlength technology for Process Tunable Diode Laser Absorption Spectrometers (TDLAS) New advances in folded pathlength technology for Process Tunable Diode Laser Absorption Spectrometers (TDLAS) Jean-Nicolas Adami, PhD Head of Strategic Product Group Gas Analytics Mettler-Toledo GmbH,

More information

h p λ = mν Back to de Broglie and the electron as a wave you will learn more about this Equation in CHEM* 2060

h p λ = mν Back to de Broglie and the electron as a wave you will learn more about this Equation in CHEM* 2060 Back to de Broglie and the electron as a wave λ = mν h = h p you will learn more about this Equation in CHEM* 2060 We will soon see that the energies (speed for now if you like) of the electrons in the

More information

Introduction to Blackbody Sources

Introduction to Blackbody Sources Introduction to s This section contains dedicated blackbody sources for low uncertainty calibration of infrared thermometers. A range of portable primary blackbody sources combine high emissivity with

More information

White Paper Optimization of Dry Powder Particle Size Analysis

White Paper Optimization of Dry Powder Particle Size Analysis -------------------------------------------------------------------White Paper Optimization of Dry Powder Particle Size Analysis Reprinted with permission from VertMarkets, Inc Optimization of Dry Powder

More information

XBC300 Gen2. Fully-automated debonder and Cleaner

XBC300 Gen2. Fully-automated debonder and Cleaner XBC300 Gen2 Fully-automated debonder and Cleaner XBC300 Gen2 FULLY AUTOMATED DEBONDER AND CLEANER The SUSS XBC300 Gen2 debonder and cleaner platform is designed for process development as well as high

More information

GS110. IR Thermal Imaging System for Low-Emissivity Glass with Automatic Emissivity Correction. Manual Addendum

GS110. IR Thermal Imaging System for Low-Emissivity Glass with Automatic Emissivity Correction. Manual Addendum GS110 IR Thermal Imaging System for Low-Emissivity Glass with Automatic Emissivity Correction Manual Addendum Rev. B 10/2006 1 Safety Instructions All notices regarding safety and acceptable operation

More information

ITS. One of the highest resolutions for particle sizing and counting. Multisizer 3 COULTER COUNTER SCIENCE

ITS. One of the highest resolutions for particle sizing and counting. Multisizer 3 COULTER COUNTER SCIENCE ITS SCIENCE ITS SCIENCE Sp. z o.o. Sp. K. Poświętne 25B, 26-670 Pionki +48 48 612 71 65 www.itsscience.pl One of the highest resolutions for particle sizing and counting. Multisizer 3 COULTER COUNTER Blood

More information

Contents. What is AFM? History Basic principles and devices Operating modes Application areas Advantages and disadvantages

Contents. What is AFM? History Basic principles and devices Operating modes Application areas Advantages and disadvantages Contents What is AFM? History Basic principles and devices Operating modes Application areas Advantages and disadvantages Figure1: 2004 Seth Copen Goldstein What is AFM? A type of Scanning Probe Microscopy

More information

EVEN THE FINEST CANNOT ESCAPE. Wöhler SM 500 Suspended Particulate Analyser

EVEN THE FINEST CANNOT ESCAPE. Wöhler SM 500 Suspended Particulate Analyser EVEN THE FINEST CANNOT ESCAPE. Wöhler SM 500 Suspended Particulate Analyser The latest innovation in total Suspended Particulate Matter (SPM) measurement The Measure of Technology Made in Germany TÜV CERTIFIED

More information

PYCKO SCIENTIFIC LIMITED

PYCKO SCIENTIFIC LIMITED PYCKO SCIENTIFIC LIMITED 31 London Road, Grantham, NG31 6EX Telephone 01476 401992 bill@pycko.co.uk www.pycko.co.uk Your Alternative To The Obvious RayMon10 TM Detect, measure, identify and analyse radionuclides

More information

Dual Beam Helios Nanolab 600 and 650

Dual Beam Helios Nanolab 600 and 650 Dual Beam Helios Nanolab 600 and 650 In the Clean Room facilities of the INA LMA, several lithography facilities permit to pattern structures at the micro and nano meter scale and to create devices. In

More information

Automated multi-vapor gravimetric sorption analyzer for advanced research applications

Automated multi-vapor gravimetric sorption analyzer for advanced research applications Automated multi-vapor gravimetric sorption analyzer for advanced research applications Automated multi-vapor gravimetric sorption analyzer for advanced research applications Key benefits of the DVS Advantage

More information

Low Vibration Cryogenic Equipment

Low Vibration Cryogenic Equipment PAGE 12 PAGE 13 ATTOCUBE S CRYOSTATS ATTODRY attodry1000....................... 14 cryogen-free cryostats with/without s attodry700.........................18 cryogen-free table-top cryostats with optical

More information

v = 00,20 m/s Thermal Flow Sensors TA with thin-film sensor element Probes Probe guides Measuring tubes

v = 00,20 m/s Thermal Flow Sensors TA with thin-film sensor element Probes Probe guides Measuring tubes with thin-film sensor element Probes Probe guides Measuring tubes Examples of Application Flow measurements also in hazardous locations Ex zone 0 or zone 1 in clean rooms in air conditioning and ventilating

More information

Long-range Hunting Optics

Long-range Hunting Optics Leading-edge Long-range Hunting Optics New: Victory FL Diavari 2 Outstanding imaging performance, maximum precision and utmost aiming accuracy the new riflescope their target at maximum magnification with

More information

Moisture Analyzers.

Moisture Analyzers. Moisture Analyzers MS-70/MX-50 MF-50/ML-50 http://www.aandd.jp Select the best for your applic A&D's Moisture Analyzers MS-70/MX-5 MS-70/MX-5 Fast and uniform heating with halogen lamp and innovative SRA

More information

Instrumentation and Operation

Instrumentation and Operation Instrumentation and Operation 1 STM Instrumentation COMPONENTS sharp metal tip scanning system and control electronics feedback electronics (keeps tunneling current constant) image processing system data

More information

MN-ISO-2000FN-E. ISO-2000FN COATING THICKNESS GAGE OPERATION MANUAL

MN-ISO-2000FN-E.   ISO-2000FN COATING THICKNESS GAGE OPERATION MANUAL MN-ISO-2000FN-E www.insize.com ISO-2000FN COATING THICKNESS GAGE OPERATION MANUAL V0 Place the probe on the zero plate and wait until beep. Lift the probe for minimal 5 cm off the zero plate and wait

More information

Maintianing Validation and Calibration. Version 01. Rev 01.

Maintianing Validation and Calibration. Version 01. Rev 01. T E C H N I C A L P A P E R Maintianing Validation and Calibration Version 01. Rev 01. Validation, Calibration Assure Investigation Accuracy In 1984, I purchased a 77 charcoal gray, Datsun 280Z from a

More information

Ion Pump Applications

Ion Pump Applications Gamma Vacuum Gamma Vacuum designs, manufactures, and services ion pumps, titanium sublimation pumps, and their controls. We have grown to be an industry leading ion pump supplier through superior quality,

More information

Thermo Scientific K-Alpha + XPS Spectrometer. Fast, powerful and accessible chemical analysis for surface and thin film characterization

Thermo Scientific K-Alpha + XPS Spectrometer. Fast, powerful and accessible chemical analysis for surface and thin film characterization Thermo Scientific K-Alpha + XPS Spectrometer Fast, powerful and accessible chemical analysis for surface and thin film characterization X-ray Photoelectron Spectroscopy Quantitative, chemical identification

More information

Introduction to Fourier Transform Infrared Spectroscopy

Introduction to Fourier Transform Infrared Spectroscopy Introduction to Fourier Transform Infrared Spectroscopy Introduction What is FTIR? FTIR stands for Fourier transform infrared, the preferred method of infrared spectroscopy. In infrared spectroscopy, IR

More information

opticalcon QUAD Technical Paper

opticalcon QUAD Technical Paper opticalcon QUAD Technical Paper Neutrik AG Im alten Riet 143 9494 Schaan Liechtenstein Copyright 2010 Neutrik AG All rights reserved. Version 4 Page 1/20 Subject: M e c h a n i c a l, e l e c t r i c a

More information

Defining quality standards for the analysis of solid samples

Defining quality standards for the analysis of solid samples Defining quality standards for the analysis of solid samples Thermo Scientific Element GD Plus Glow Discharge Mass Spectrometer Redefine your quality standards for the elemental analysis of solid samples

More information

Analysis of Polymers and Plastics. Innovation with Integrity. Quality Control & Failure Analysis FTIR

Analysis of Polymers and Plastics. Innovation with Integrity. Quality Control & Failure Analysis FTIR Analysis of Polymers and Plastics Quality Control & Failure Analysis Innovation with Integrity FTIR Quality Control for Cost-Efficiency Plastics are used in countless products such as automotive parts,

More information

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes Examples of Application Flow measurements also in hazardous locations X zone 0 or zone 1 in clean rooms in air

More information

ACCEPTANCE PROCEDURE FOR ROMET ROTARY METER BODIES AND/OR MECHANICAL NON-CONVERTING AND CONVERTING MODULES

ACCEPTANCE PROCEDURE FOR ROMET ROTARY METER BODIES AND/OR MECHANICAL NON-CONVERTING AND CONVERTING MODULES ACCEPTANCE PROCEDURE FOR ROMET ROTARY METER BODIES AND/OR MECHANICAL NON-CONVERTING AND CONVERTING MODULES (RPB-01) Approved by: Date: SECTION PAGE # 1.0 Scope 2.0 Definitions 3.0 References 4.0 Inspection

More information

Microscopy Cryostat System

Microscopy Cryostat System OF AMERICA, INC. Microscopy Cryostat System RC102-CFM Microscopy Cryostat offers fast cooldown, high efficiency, lowest thermal drift, excellent temperature stability and ultra low vibration Optical cryostat

More information

Spa & Wellness for Pipettes

Spa & Wellness for Pipettes epservices for premium performance Spa & Wellness for Pipettes Pipette Performance Plans Treat your pipettes well with premium services from the experts! Total approach philosophy For over 60 years Eppendorf

More information

ABC s of Electrochemistry series Materials Characterization techniques: SEM and EDS Ana María Valenzuela-Muñiz November 3, 2011

ABC s of Electrochemistry series Materials Characterization techniques: SEM and EDS Ana María Valenzuela-Muñiz November 3, 2011 ABC s of Electrochemistry series Materials Characterization techniques: SEM and EDS Ana María Valenzuela-Muñiz November 3, 2011 CEER, Department of Chemical and Biomolecular Engineering Outline Introduction

More information

RS-C Flexible Reticle Stocker

RS-C Flexible Reticle Stocker RS-C Flexible Reticle Stocker CONTAMINATION CONTROL SOLUTIONS Benefits Secure reticle storage Tec-Cell technology Prolongs the reticle lifetime Fast reticle access time Full Flexibility The RS-C is a fully

More information

Extrel is widely respected for the quality of mass spectrometer systems that are

Extrel is widely respected for the quality of mass spectrometer systems that are Extrel is widely respected for the quality of mass spectrometer systems that are available to the world's top research scientists. In response to increasing requests for complete turn-key systems built

More information

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities instruments 5 YEARS G U A R A N T E E Quality at a reasonable price The optimum combination

More information

429 LIGHT DIFFRACTION MEASUREMENT OF PARTICLE SIZE

429 LIGHT DIFFRACTION MEASUREMENT OF PARTICLE SIZE Search USP29 429 LIGHT DIFFRACTION MEASUREMENT OF PARTICLE SIZE Light diffraction is one of the most widely used techniques for measuring the size of a wide range of particles from very fine to very coarse.

More information