PTG-NIR Powder Characterisation System (not yet released for selling to end users)
|
|
- Dorcas Tyler
- 5 years ago
- Views:
Transcription
1 Powder Characterisation System - PTG-NIR PTG-NIR Powder Characterisation System (not yet released for selling to end users) The PTG-NIR automatic powder and granule inspection system with integrated NIR spectrometer may be used to examine the flow characteristics of a powder or granule. The combination of a Powder Testing System with a NIR Diode Array spectrometer shall be used for simultaneous detection of chemical, physical and morphological information. This information is describing the flow behaviours of a powder or granule. Other forms of solids are possible to be tested too. All the parameters are shown as one result: The flow property. The automated PTG S3 stand-alone powder testing system is used to measure the flow behaviour of granules and powders in compliance with the EP <2.9.36> and USP <1174> pharmacopoeia and ISO 4324 standards. It has a self contained balance and a built in printer for a compact foot print. The all stainless finish (for GMP compliance), is easy to clean and maintain _09.1.0E Page 1 of 5
2 Powder Characterisation System - PTG-NIR The NIR Diode Array spectrometer is built-into a separate stainless steel box from which the fibre optic cable is directly connected to the PTG S3 instrument. This combination is the PTG-NIR. The NIR measurement accessory will greatly enhance the application range of this instrument. Greatly expanded application range The PTG-NIR will be equipped with an addition NIR Diode Array spectrometer, from which the fibre probe neatly fits into the powder flow nozzle holder for the additional analysis of: Qualitative finger printing of powder content Moisture content API concentration Homogeneity of blended components This important step forward means that the range of analytical information available from a single powder sample has now been greatly increased. In Pharmaceutical applications, we can now analyse all incoming raw materials (e.g., nonactive ingredients) for their official content as well as the water content. Blends of the non-active materials can also now be analysed for flow characteristics as well as important features such as water content which will affect the way that the powder mix will flow into the tabletting machine for example. The example below shows the ability of the system to shed light on the increased concentration of sugar in the excipient blend. It can also shed light on the distribution of an API within a powder blend. This can now be extended to give indications for content uniformity. Powder Characterisation is Critical Absorbance [AU] ,2% Zucker 80,4% Zucker 81,8% Zucker 85,7% Zucker 90% Zucker 100% Zucker Analysis of Blended Components. Note the clearly indicated increase in sucrose concentration shown by the PTGS NIR Analyser Wellenlänge [nm] _09.1.0E Page 2 of 5
3 Applications for this system are: Determination of these properties in the goods inspection Determining the required properties prior to the processing of intermediate products, especially considering (e.g. capsule filling) or injection (e.g. Tablet Press) The study of segregation operations The PTG-NIR is a robust laboratory analysis system. In this case is the NIR spectrometer with a fibre optic cable connected with the PTG S3. Functioning of the Set-Up: The material is inside a conical hopper within the PTG S3 Powder testing System. The powder is poured through a flow nozzle, the size is selected according to the particle size and flow capacity of the test material. After opening the funnel cap the powder is captured on a table and forms a conical pile. These tests can be selected by the user: Flow time, the Bulk Cone (cone angle or angle of repose), the Cone Volume, Weight and Density and the Weight Increase. All data are registered and documented. Additionally the powder flow stream which passes the measuring optics which is connected via a fibre cable with the spectrometer will be analysed. The beam penetrates only about 1/10 to 3/10 mm into the product stream and is reflected by its particles. The optical analysis is done without product contact, contamination-free and non-destructive. The quantity of tested material is generally 100 to 350 ml. The resulting flow time is usually only a couple of seconds. In order to receive as much information as possible, it is necessary that the spectral range in size, resolution and a sufficient number of spectra is recorded for a profile which is representative. Typical is the set-up are about 50 spectra for the flow time experiment. Those requirements can only be offered using a Diode Array Spectrometer based technology. Other techniques such as FT-NIR, AOTF or others, are not suitable due to the speed requirement to collect full spectra. What is fundamentally necessary to use of the system? NIR calibration data with corresponding reference methods are necessary because the NIR reflectance spectroscopy is a method, which only relative sizes can spawn. Thus, it is recommended, to calibrate the moisture content with LOD or Karl Fischer titration. Other concentrations have to be calibrated by orthogonal reference methods. This effort initially seems great, but usually it is known for quantitative analysis in the lab. The analysis and evaluation of the spectra is done using chemometrical procedures. Simple linear models to complex nonlinear models are possible. Software: The system software should be very easy to operate and has 4 different user levels. In the "operator" mode, only analysis with preset measurement and evaluation parameters is possible. After the analysis a full report is filed and may be printed. This type of instrumentation is easily used to provide: Reduction in cost of raw process materials: reject bad batches before processing Maintenance of the optimum formulation for the process concerned Reduction in process costs Maintain the quality and consistency of the final product _09.1.0E Page 3 of 5
4 Maintain process efficiency and costs by optimisation of product storage, packing, handling and transportation. Maintain powder quality from different suppliers or from the same supplier over a long time period; use the finger print facility of the PTGS3 NIR for rapid QC checks. Development of new processes where powders are required to be formulated into end products. Check moisture effects: use of powders in open systems in different climates; use the NIR option for water content control. Investigating and maintaining the quality of dry mixes What else can the PTG-NIR do for me? The PTG-NIR can also be used to great effect in order to: Improve product consistency from batch to batch Keep tight control of component powders, especially if they are natural products Compare sources of powdered products: both excipients and APIs. Easy method to achieve quality control on bulk incoming component products Easy method for the control of dry and wet mixing, tabletting, granulating, and capsule filling Prediction of powder transport through conveyors, air lifts and in silos Prediction of powder suitability for capsule and bottle filling Prediction of product settling during transport, so called classification Prediction of powdered mix influence on tablet hardness and solid dosage form stability Prediction of powder influence on tablet disintegration and friability The physical parameters measured by the PTG-NIR: Powder Flow Time of a pre defined mass Powder cone volume Powder cone density Cone Angle (Angle of Repose EP <2.9.36>, USP <1174>) Flowability of 100 mg of product (EP/DAB <2.9.36>, USP <1174> pharmacopoeia) Amount of sample (mg in a preset time) Flow Chart of sample (mg/time) Technical Details of the PTG Powder Tester Display: LCD Display Keyboard: alpha-numerical and function keys Key entries: 12 digit product code 12 digit batch number Volume of the st. steel cone: approx. 450 ml Range for cone angle*: 1.0 to 45.0 Range for "flowability" test*: 0.1 sec. to 999 sec. - mass: 100 g Range for flow time test*: 0.1 sec. to 999 sec. Cone density*: g/ml -1 to 6.0 g/ml -1 Cone weight*: 1 mg to 325 g Cone volume*: 0.1 ml to 275 ml Interface: RS-232 serial interface _09.1.0E Page 4 of 5
5 Printer: Instrument housing: Included documentation: built-in Thermo Printer and/or external Parallel printer port stainless steel to meet GLP requirements GLP compliant IQ/OQ Documentation * theoretically maximum measurable data by the built-in electronics Technical Data for the NIR Analyser Wavelength range: Wavelength Accuracy: Wavelength reproducibility: Pixel distance: Noise : Baseline stability: Scan speed: nm < 1nm (at nm, nm & nm) < 0. 1 nm 3.9 nm Max.< 0.8mAU. Mean <0.3mAU < 3 mau / hour (at 1400 nm and 1700 nm) 20 Spectra / sec Detection system (Mono-fibre) Connector Type (Spectrometer): FSMA 905 Connector Type (PTGS3): 3 mm Fibre Diameter: 600μm Numerical Aperture: 0.22 Illumination Fibre (bundle) Light source Connection: FSMA 905 PTGS3 Connection: 3mm Light Fibre diameter: 6 x 600μm Numerical Aperture: 0.22 Halogen Light Source Power: 7.5W Supply Voltage: 5V Connector: FSMA 905 Options PTG-NIR: 10 ml small volume test set, includes POM funnel, stirrer, sample collecting dish, validation cone Dust Hood made from brown coloured Plexiglas, includes front door, vacuum exhauster connection tube Net weight: Gross weight: Packaging: 48 kg 65 kg 900 mm x 750 mm x 750 mm The PTG-NIR is yet not available. The functionality, its data reproducability and also economical sales aspects are still under investigation (Aug. 2010) _09.1.0E Page 5 of 5
Putting Near-Infrared Spectroscopy (NIR) in the spotlight. 13. May 2006
Putting Near-Infrared Spectroscopy (NIR) in the spotlight 13. May 2006 0 Outline What is NIR good for? A bit of history and basic theory Applications in Pharmaceutical industry Development Quantitative
More informationBIO & PHARMA ANALYTICAL TECHNIQUES. Chapter 5 Particle Size Analysis
BIO & PHARMA ANALYTICAL TECHNIQUES Chapter 5 by Dr Siti Umairah Mokhtar Faculty of Engineering Technology umairah@ump.edu.my Chapter Description Aims Discuss theory, principles and application of analytical
More informationMeasuring the flow properties of powders. FT4 Powder Rheometer. freemantechnology
Measuring the flow properties of powders FT4 Powder Rheometer freemantechnology Efficiency, quality and productivity Successful powder processing requires the ability to reliably and repeatably predict
More informationVerification of Pharmaceutical Raw Materials Using the Spectrum Two N FT-NIR Spectrometer
APPLICATION NOTE FT-NIR Spectroscopy Authors: Ian Robertson Jerry Sellors PerkinElmer, Inc. Seer Green, UK Verification of Pharmaceutical Raw Materials Using the Spectrum Two N FT-NIR Spectrometer Introduction
More informationTechnical brochure DuraLac H TABLETING DIRECT COMPRESSION ANHYDROUS LACTOSE
U A AC Technical brochure TABLETING DIRECT COMPRESSION ANHYDROUS LACTOSE MEGGLE anhydrous lactose grade for direct compression: General information Direct compression (DC) tablet manufacture is a popular
More informationActiPix SDI300 Surface Dissolution Imaging System
Product Note: PN002B Figure 1. SDI300 Surface Dissolution Imaging System Introduction The ActiPix SDI300 is a powerful UV area imaging system which enables quantitative imaging of surface phenomena for
More informationTHERAPEUTIC GOODS SAMPLING Application to Tablet Manufacture and Ingredients. David Edmonds CMC Regulatory
THERAPEUTIC GOODS SAMPLING Application to Tablet Manufacture and Ingredients 1 David Edmonds CMC Regulatory Sampling requirements Code of GMP PE009-11 Part 1/March 2014 The basic requirements of Quality
More informationWhole Tablet Measurements Using the Frontier Tablet Autosampler System
a p p l i c a t i o n N O T E Whole Tablet Measurements Using the Frontier Tablet Autosampler System FT-NIR Spectroscopy Introduction Recent advances in NIR technology have changed the ways in which both
More informationAutomatic titrators, TitroMatic
112 TitroMatic These are the fourth generation of CRISON titrators. CRISON has over 25 years experience in this field and knows that, for certain applications, the performance and cost of large titrator
More informationParticle Characterization of Pharmaceutical Products by Dynamic Image Analysis
WHITE PAPER Particle Characterization of Pharmaceutical Products by Dynamic Image Analysis Retsch Technology GmbH Retsch-Allee 1-5 42781 Haan, Germany Phone: +49 24/2333-0 E-Mail: technology@retsch.com
More informationQbD QUANTITATIVE MEASUREMENTS OF CQAS IN SOLID DOSAGE FORM UNIT OPERATIONS
QbD QUANTITATIVE MEASUREMENTS OF CQAS IN SOLID DOSAGE FORM UNIT OPERATIONS Particle Size Material Segregation-Flow USP USP USP Ph. Eur. 2.9.31 Ph. Eur. 2.9.36 JP 1 JP 18 Light Diffraction
More informationWhole Tablet Measurements Using the Spectrum One NTS Tablet Autosampler System
Whole Tablet Measurements Using the Spectrum One NTS Tablet Autosampler System A P P L I C A T I O N N O T E Introduction Recent advances in NIR technology have changed the ways in which both the pharmaceutical
More informationTendency of blends for segregation
Tendency of blends for segregation How to study it? Methods for measuring the segregation potential Louk Peffer 1 Outline/Themes Blends unmix Theory or reality Visual inspection Segregation mechanisms
More informationTo Hy-Ternity and beyond. Boris Larchevêque, INDATECH
To Hy-Ternity and beyond Boris Larchevêque, INDATECH Hello! Are you still thinking that a lonely spectrum can make you see how beautiful we are? A 25 minutes talk Introduction to SRS Industrial point of
More informationWater in Food 3 rd International Workshop. Water Analysis of Food Products with at-line and on-line FT-NIR Spectroscopy. Dr.
Water in Food 3 rd International Workshop Water Analysis of Food Products with at-line and on-line FT-NIR Spectroscopy Dr. Andreas Niemöller Lausanne 29th 30th March 2004 Bruker Group Company Technology
More information610,- KERN ADB. Analytical balances. Quick-Finder Analytical balances. Large glass draught shield with 3 sliding doors
Quick-Finder Readout [d] mg Weighing [Max] g Price excl. of VAT Page 0,01 101 ABT 100-5NM 1980,- 39 1 0,01 0,1 42 120 ABT 120-5DNM 2120,- 39 1 0,01 0,1 82 220 ALJ 200-5DA 1750,- 37 1 0,01 0,1 82 220 ABT
More informationSwiss Medic Training Sampling
Swiss Medic Training Sampling Paul Sexton Sampling Preparation for Sampling Representative Sample Re-sampling Sampling Part I What to sample? Why sample? Where to sample? Who performs sampling? How to
More informationMeasurement & Analytics Measurement made easy. MB3600-CH70 FT-NIR polyol analyzer Pre-calibrated for OH value determination
Measurement & Analytics Measurement made easy MB3600-CH70 FT-NIR polyol analyzer Pre-calibrated for OH value determination Adapted for polyols and polyurethanes applications The MB3600-CH70 Polyol Analyzer
More informationOne-hand ph/temperature measuring instrument
One-hand ph/temperature measuring instrument testo 205 ph tip embedded in breakage-proof plastic ph Combined penetration tip with temperature probe Maintenance-free gel electrolyte C Measurement tip exchangeable
More informationUse of Near Infrared Spectroscopy for in- and off-line performance determination of continuous and batch powder mixers: opportunities & challenges
Available online at www.sciencedirect.com Procedia Food Science 1 (2011) 2015 2022 11 th International Congress on Engineering and Food (ICEF11) Use of Near Infrared Spectroscopy for in- and off-line performance
More informationSemi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities
Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities instruments 5 YEARS G U A R A N T E E Quality at a reasonable price The optimum combination
More informationKarl-Fischer Titration the method for determining water
Karl-Fischer Titration the method for determining water Quite some experienced analyst will be unpleasantly reminded by the pyridine smell, when hearing the name Karl Fischer. However, modern reagents
More informationRS-C Flexible Reticle Stocker
RS-C Flexible Reticle Stocker CONTAMINATION CONTROL SOLUTIONS Benefits Secure reticle storage Tec-Cell technology Prolongs the reticle lifetime Fast reticle access time Full Flexibility The RS-C is a fully
More informationNaturalFacts. Introducing our team. New product announcements, specials and information from New Roots Herbal. April 2009
NaturalFacts New product announcements, specials and information from New Roots Herbal April 2009 Introducing our team Introducing Our Science Team Dr. ABZAL HOSSAIN Ph.D. Analytical Chemistry Dr. Hossain
More informationPharmaceutical Characterisation. Dr. Lidia Tajber and Dr. Krzysztof Paluch School of Pharmacy and Pharmaceutical Sciences, Trinity College Dublin
Pharmaceutical Characterisation Dr. Lidia Tajber and Dr. Krzysztof Paluch School of Pharmacy and Pharmaceutical Sciences, Trinity College Dublin Characterisation for Pharma Active pharmaceutical ingredients
More informationIntroduction to Fourier Transform Infrared Spectroscopy
Introduction to Fourier Transform Infrared Spectroscopy Introduction What is FTIR? FTIR stands for Fourier transform infrared, the preferred method of infrared spectroscopy. In infrared spectroscopy, IR
More informationAutomated multi-vapor gravimetric sorption analyzer for advanced research applications
Automated multi-vapor gravimetric sorption analyzer for advanced research applications Automated multi-vapor gravimetric sorption analyzer for advanced research applications Key benefits of the DVS Advantage
More informationTECHNICAL DESCRIPTION SPECTRAFLOW ON LINE ANALYZER for BELT CONVEYOR APPLICATION
TECHNICAL DESCRIPTION SPECTRAFLOW ON LINE ANALYZER for BELT CONVEYOR APPLICATION TECHNICAL SPECIFICATION SPECTRAFLOW ON LINE ANALYZER FOR BELT CONVEYOR CONTENTS 1. SpectraFlow Technical Description...
More informationFundamentals of Particle Counting
Fundamentals of Particle Counting 1 Particle Counting: Remains the most significant technique for determining the cleanliness level of a fluid Useful as a tool for qualification and monitoring cleanroom
More informationIntroduction to Fourier Transform Infrared Spectroscopy
molecular spectroscopy Introduction to Fourier Transform Infrared Spectroscopy Part of Thermo Fisher Scientific Introduction What is FT-IR? FT-IR stands for Fourier Transform InfraRed, the preferred method
More informationThermo Scientific Orion Star T900 Series Laboratory Titrators. Potentiometric titrators for performing automated ph, redox, or ion titrations
Thermo Scientific Orion Star T900 Series Laboratory Titrators Potentiometric titrators for performing automated ph, redox, or ion titrations Thermo Scientific Orion Star T900 Series Titrators Automate
More informationRS 1700/1900/2300/2900 High Density Reticle Stockers
RS 1700/1900/2300/2900 High Density Reticle Stockers CONTAMINATION CONTROL SOLUTIONS Benefits Secure reticle storage Tec-Cell technology Prolongs the reticle lifetime Fast reticle access time High storage
More informationnext generation Welcome to the Dispersion options Smarter particle sizing Your sample, expertly processed and prepared Particle size
Particle size Welcome to the next generation Your sample, expertly processed and prepared Dispersion options 3000 detailed specification sheets from Getting your sample preparation right The US Pharmacopeia
More informationFrom 1 ppm to 100% Karl Fischer water content determination
METTLER TOLEDO Karl Fischer Titrators DL39 & DL32 Coulometers DL38 & DL31 Volumeters Oven sample changer Stromboli From 1 ppm to 100% Karl Fischer water content determination Karl Fischer water content
More informationAgilent Cary 630 FTIR sample interfaces combining high performance and versatility
Agilent Cary 630 FTIR sample interfaces combining high performance and versatility Technical Overview Introduction The Agilent Cary 630 is a robust, easy to use, superior performing FTIR in a compact package.
More informationBiochrom Libra. UV-Visible Spectrophotometers. High performance instruments with added application value for academia, research and industry
New Double Beam Spectrophotometers Biochrom Libra UV-Visible Spectrophotometers High performance instruments with added application value for academia, research and industry Biochrom Libra Real Choice
More informationEasy and reliable KF titrations From 1 ppm to 100%
AGC Karl Book Fischer 20% Titrators Cyan Volumetric KF Titrators DL31, DL38 Coulometric KF Titrators DL32, DL39 Oven sample changer Stromboli Easy and reliable KF titrations From 1 ppm to 100% Karl Fischer
More informationKjeltec 2300 Analyzer Unit
Kjeltec 2300 Analyzer Unit Automatic distillation and approved colorimetric titration for analysis of Kjeldahl nitrogen/protein, ammonium- nitrogen, TKN, Direct distillation (DD), volatile acids/ bases
More informationIntroducing the Morphologi G3 ID The future of particle characterization
Introducing the Morphologi G3 ID The future of particle characterization Dr Anne Virden, Product technical specialist diffraction and analytical imaging What is the Morphologi G3-ID? Advanced R&D particle
More informationDM70 Hand-Held Dewpoint Meter for Spot-Checking Applications
DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed
More informationTHE INTRODUCTION OF PROCESS ANALYTICAL TECHNOLOGY, USING NEAR INFRARED ANALYSIS, TO A PHARMACEUTICAL BLENDING PROCESS
THE INTRODUCTION OF PROCESS ANALYTICAL TECHNOLOGY, USING NEAR INFRARED ANALYSIS, TO A PHARMACEUTICAL BLENDING PROCESS Krishel Naicker a, Gareth Kilian a * and Johan Olivier b a Nelson Mandela Metropolitan
More informationDetection of trace contamination on metal surfaces using the handheld Agilent 4100 ExoScan FTIR
Detection of trace contamination on metal surfaces using the handheld Agilent 4100 ExoScan FTIR Ensuring ultimate cleanliness for maximum adhesion Application Note Author John Seelenbinder Agilent Technologies,
More informationICP-MS. High Resolution ICP-MS.
ICP-MS attom ES High Resolution ICP-MS www.nu-ins.com Attom ES Enhanced Sensitivity Enhanced Speed Enhanced Selectivity Enhanced Software The Attom ES from Nu Instruments is a double focussing inductively
More informationSPECIFICATIONS PARTICLE SENSOR KS-28B Higashimotomachi, Kokubunji, Tokyo , Japan
SPECIFICATIONS PARTICLE SENSOR KS-28B 3-20-41 Higashimotomachi, Kokubunji, Tokyo 185-8533, Japan No. 99020-4E 07-04 Printed in Japan Outline The KS-28B is a particle sensor designed to measure the number
More informationDVS Intrinsic Compact and Economical Dynamic Vapor Sorption System
DVS Intrinsic Compact and Economical Dynamic Vapor Sorption System The easy-to-use solution to complex water sorption challenges from SMS: High quality water isotherms and efficient water activity measurements
More informationSPECTROPHOTOMETERS. Visible and UV-Visible
Visible and UV-Visible The Manifacturer ONDA Spectrophotometers are manifactured by a company with over than ten years of experience in development of UV/Vis instruments, Single beam and Double beam, with
More informationMoisture Analyzers.
Moisture Analyzers MS-70/MX-50 MF-50/ML-50 http://www.aandd.jp Select the best for your applic A&D's Moisture Analyzers MS-70/MX-5 MS-70/MX-5 Fast and uniform heating with halogen lamp and innovative SRA
More informationNOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.
NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation. SCANNING UV VISIBLE SPECTROPHOTOMETER Features SCANNING UV VISIBLE SPECTROPHOTOMETER
More informationImplementing Fundamental Pharmaceutical Science and Materials/Engineer Expertise in Scale-up
Implementing Fundamental Pharmaceutical Science and Materials/Engineer Expertise in Scale-up 2 nd FDA/PQRI Conference on Advancing Product Quality Session: The Science of Tech Transfer/Scale-up North Bethesda,
More informationDrug Testing Solutions INDIKO DRUG TESTING ANALYZER. 1 P F
Drug Testing Solutions INDIKO DRUG TESTING ANALYZER 1 www.dtpm.ws P. 256-845-1261 F. 888-317-4178 sales@dtpm.ws Overview Indiko Sample oriented random access system for clinical and specialty testing,
More informationTABLE OF CONTENTS. vii
TABLE OF CONTENTS S. No. Description Page No. CHAPTER-I 1.0 Introduction 1 CHAPTER-II 2.0 Literature Review 5 2.1 History 6 2.2 Formulation Theory 7 2.3 Properties of Nanoparticles 9 2.4 Existing Technologies
More informationThe Plus for your lab!
BioPhotometer plus NEW! analysis system The Plus for your lab! The easy, rapid and reliable BioPhotometer plus analysis system See it clearly! UVette Precision in plastics The patented* 1 UVette is the
More information1/5 Specifications Hidex 300 SLL automatic TDCR liquid scintillation counter
1/5 Specification Hidex 300 SL-SLL 100-240V AC and 24 V DC. Features Model (425-020) Super Low Level (SLL) Automatic TDCR Liquid Scintillation Counter with Guard Detector and Low Level PMTs General Description
More informationLABORATORY LINE. REACTRON RT 1 and RT 2. Reaction and mixing processes at a laboratory level, modular design laboratory reactors
LABORATORY LINE REACTRON RT 1 and RT 2 Reaction and mixing processes at a laboratory level, modular design laboratory reactors Efficient and economic. RT 1 and RT 2 REACTRON laboratory systems consist
More informationFACULTY OF PHARMACY. M. Pharmacy I Semester (Suppl.) Examination, November 2015 (Common To All) Subject: Pharmaceutical Analytical Techniques
M. Pharmacy I Semester (Suppl.) Examination, November 2015 (Common To All) Subject: Pharmaceutical Analytical Techniques Code No. 6001 / S Note: Answer any Five questions. All questions carry equal marks.
More informationThe solution for all of your
The solution for all of your nanoparticle sizing and zeta potential needs. DelsaNano Series Blood Banking Capillary Electrophoresis Cell Analysis Centrifugation Genomics Lab Automation Lab Tools Particle
More informationThermal Analysis Excellence
Thermal Analysis Excellence Sorption Test Systems SPS11-1µ SPSx-1µ High Load SPSx-1µ Advance SPS23-1n Multi-Sample Moisture Sorption Analysis Simple, Accurate and Reliable Sorption Test Systems Moisture
More informationChapter 4: Verification of compendial methods
Chapter 4: Verification of compendial methods Introduction In order to ensure accurate and reliable test results, the quality control laboratory (QCL) needs to use analytical methods (and accompanying
More informationJAPAN QUALITY. Automated Clinical Analyzer
JAPAN QUALITY Automated Clinical Analyzer Higher test performance and operability with new functions The clinical analyzer in the next stage 1 The best to the requirements for functionality and usability
More information2.01 INFRARED ANALYZER
NIR INFORMATION PAGE 1 OF 5 What does it do? First, it allows for better control and knowledge of incoming ingredients. If the ability exists to analyze a truck or rail car immediately upon arrival, the
More informationPharmaceutical Polymers for Tablets and Capsules
Pharmaceutical Polymers for Tablets and Capsules Edition: March 23, 2010 Wet Granulation Direct compression is not feasible for matrix formulations containing high levels of powder Carbopol polymers (>5%
More informationWATER ACTIVITY MEASUREMENT WATER ACTIVITY
MEASUREMENT WATER ACTIVITY FAST AND PRECISE WATER ACTIVITY MEASUREMENTS. INTRODUCING AIRCHIP DIGITAL TECHNOLOGY. Determine product quality with ROTRONIC Aw products ROTRONIC Aw devices for laboratory and
More informationAccurate Measurement of Transmittance and Reflectance for Engineering Applications
Accurate Measurement of Transmittance and Reflectance for Engineering Applications Dr. Chen Fangzhi Laboratory Manager Façade & Roof Materials Testing Laboratory OTM Solutions Pte Ltd PerkinElmer INTour
More informationRamanStation 400: a Versatile Platform for SERS Analysis
FIELD APPLICATION REPORT Raman Spectroscopy Author: Dean H. Brown PerkinElmer, Inc. Shelton, CT USA RamanStation 400 RamanStation 400: a Versatile Platform for SERS Analysis Introduction Surface Enhanced
More informationThe Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity
The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity Janet Hammond Waters Corporation, Wilmslow, UK APPLICATION BENEFITS High
More informationTraceable UV-Vis Reference Materials
UV-Vis Spectroscopy Traceable UV-Vis Reference Materials For Regulatory Compliance Introduction Many laboratories, particularly in the pharmaceutical industry, are under increasing pressure to show proof
More information473 Dew Point Hygrometer
gh Performance Chilled Hygrometer With Cable Mounted Measuring Heads ghly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct insertion
More informationNIR Chemical Imaging as a Process Analytical Tool
Manufacturing NIR Chemical Imaging as a Process Analytical Tool NIR chemical imaging greatly extends the capability of NIR spectroscopy, and is the only PAT-applicable blend monitoring technique that gives
More informationAnalysis of Polymers and Plastics. Innovation with Integrity. Quality Control & Failure Analysis FT-IR
Analysis of Polymers and Plastics Quality Control & Failure Analysis Innovation with Integrity FT-IR Reliable quality control is essential to achieve a cost-saving production of high quality plastic products.
More informationSpectroscopy in Transmission
Spectroscopy in Transmission + Reflectance UV/VIS - NIR Absorption spectra of solids and liquids can be measured with the desktop spectrograph Lambda 9. Extinctions up to in a wavelength range from UV
More informationß + RADIATION. Choose your application of. chromatography controlled. chemical purity TLC PET GABI. PET GABI 2x2 Nal (Tl) 0 1V output.
www.raytest.com Choose your application of ß + RADIATION chromatography stand alone software controlled chemical purity HPLC PET GABI 2x2 Nal (Tl) 0 1V output PET GABI 2x2 Nal (Tl) Gina-PCcontrolled TLC
More informationDVS INTRINSIC. The easy-to-use solution to complex water sorption challenges.
DVS INTRINSIC The easy-to-use solution to complex water sorption challenges www.surfacemeasurementsystems.com D V S I n t rin s i c The easy-to-use solution to complex water sorption challenges from Surface
More informationManufacturing process control with PAT Substitution of off-line HPLC & GC by in-line IR spectroscopy
Manufacturing process control with PAT Substitution of off-line HPLC & GC by in-line IR spectroscopy Christian Lautz, F. Hoffmann-La Roche Ltd, Basel, Switzerland IFPAC-2015, January 25-28, Arlington,USA
More information':-;--~_-----;;:+;:";:-- :-:;+;:-;:-- --:-::+::::--_--::-::--:-::< LAB REPORTED
JACOBSON, BEVERLY J.*, JOSEPH H. WALLEVAND, TERRY D. McGILLIVRAY, AND C. GARY FISCHER, American Crystal Sugar Co., 1700 N. 11 St., Moorhead, MN 56560. Overview of the development and application of near
More informationAnalysis of Cocoa Butter Using the SpectraStar 2400 NIR Spectrometer
Application Note: F04 Analysis of Cocoa Butter Using the SpectraStar 2400 NIR Spectrometer Introduction Near-infrared (NIR) technology has been used in the food, feed, and agriculture industries for over
More informationAcceleration/Velocity/Displacement VIBRATION METER
Acceleration/Velocity/Displacement VIBRATION METER Model : VB-8220 Your purchase of this VIBRATION METER marks a step forward for you into the field of precision measurement. Although this METER is a complex
More informationVALIDATION OF ANALYTICAL METHODS. Presented by Dr. A. Suneetha Dept. of Pharm. Analysis Hindu College of Pharmacy
VALIDATION OF ANALYTICAL METHODS Presented by Dr. A. Suneetha Dept. of Pharm. Analysis Hindu College of Pharmacy According to FDA,validation is established documented evidence which provides a high degree
More informationThermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer
IET International Equipment Trading Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Thermo Scientific LTQ Orbitrap Velos
More informationDM70 Hand-Held Dewpoint Meter for Spot-Checking Applications
DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed
More information473 Dew Point Hygrometer
High Performance Chilled Mirror Hygrometer With Cable Mounted Measuring Heads Highly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct
More informationCorn Sugar (crude & refined) Analysis F MOISTURE (Karl Fischer)
Corn Sugar (crude & refined) Analysis F-32-1 MOISTURE (Karl Fischer) PRINCIPLE SCOPE The sugar sample is dissolved in a mixture of methanol and formamide (50:50 v/v) and then titrated with standardized
More informationAutomated Clinical Analyzer
Automated Clinical Analyzer Improved ease of operation and better test efficiency, and provides the optimal solution for routine operations, STAT operation and a broad range of clinical analysis requirements.
More informationADI 2040 Process Analyzer
ADI 2040 Process Analyzer Multi-purpose wet chemical analysis Multi-purpose Wet Chemical Analysis ADI 2040 The Metrohm Applikon ADI 2040 Process Analyzer is a multipurpose wet chemical analyzer, that has
More informationCompact ph Measuring Instruments With Pro Engineering
testo 205, 206, 230 Compact ph Measuring Instruments With Pro Engineering With interchangeable measurement electrode ph C The new ph instruments with innovative probe engineering Measurement of the ph
More informationVaisala DRYCAP Hand-Held Dewpoint Meter DM70. Fast Response - Low Maintenance
Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 Fast Response - Low Maintenance DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand- Held Dewpoint Meter DM70 offers accurate
More informationFormulation of Low Dose Medicines - Theory and Practice
Hashim Ahmed, Ph.D. and Navnit Shah, Ph.D. Pharmaceutical and Analytical R&D, Hoffmann-La Roche Inc., Nutley NJ Formulation of Low Dose Medicines - Theory and Practice Progress in pharmaceutical research
More informationAcceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202
Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202 Your purchase of this VIBRATION METER marks a step forward for you into the field of precision measurement. Although this METER is
More informationAnalysis of Polymers and Plastics. Innovation with Integrity. Quality Control & Failure Analysis FTIR
Analysis of Polymers and Plastics Quality Control & Failure Analysis Innovation with Integrity FTIR Quality Control for Cost-Efficiency Plastics are used in countless products such as automotive parts,
More informationApplication of Ring Shear Testing to Optimize Pharmaceutical Formulation and Process Development of Solid Dosage Forms
ANNUAL TRANSACTIONS OF THE NORDIC RHEOLOGY SOCIETY, VOL. 21, 2013 Application of Ring Shear Testing to Optimize Pharmaceutical Formulation and Process Development of Solid Dosage Forms Søren V. Søgaard
More informationApparent Melting: A New Approach to Detecting Drug-Excipient Incompatibility
Apparent Melting: A New Approach to Detecting Drug-Excipient Incompatibility Keywords: Melting Temperature, eat of Fusion, Apparent Melting, Thermodynamic Melting, Kinetic Process, Differential Scanning
More informationProtocol Particle size distribution by centrifugal sedimentation (CPS)
Protocol Particle size distribution by centrifugal sedimentation (CPS) 1. Method The CPS Disc Centrifuge separates particles by size using centrifugal sedimentation in a liquid medium. The sedimentation
More informationDemonstrating the Value of Data Fusion
Demonstrating the Value of Data Fusion Thomas I. Dearing 1 Wesley Thompson and Brian Marquardt 1 Carl Rechsteiner Jr. 2 1. Applied Physics Labs, University of Washington 2. Chevron Energy Technology, Richmond
More informationBIOLIGHT STUDIO IN ROUTINE UV/VIS SPECTROSCOPY
BIOLIGHT STUDIO IN ROUTINE UV/VIS SPECTROSCOPY UV/Vis Spectroscopy is a technique that is widely used to characterize, identify and quantify chemical compounds in all fields of analytical chemistry. The
More informationAutomated determination of the uniformity of dosage in quinine sulfate tablets using a fiber optics autosampler
Automated determination of the uniformity of dosage in quinine sulfate tablets using a fiber optics autosampler Application Note Author John Sanders. Agilent Technologies, Inc. Mulgrave, Victoria 3170,
More informationNano Spectrophotometer LNS-A10
Nano Spectrophotometer LNS-A10 Nano spectrophotometer with full spectrum light covers wide wavelength range of 200 to 800nm. It requires only 0.5-2.0µl micro-volume sample for measurement which takes place
More informationX-Ray Net Weight Control of Pharmaceutical Products
Abstract 17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China X-Ray Net Weight Control of Pharmaceutical Products Florian BESSLER 1 and Walter BAUER 1 1: Robert Bosch GmbH,
More informationSmart Sensing Embedded Spectroscopy Platform Botlek studiegroep 06-april-2017
Smart Sensing Embedded Spectroscopy Platform Botlek studiegroep 06-april-2017 W. Karremans Personal introduction Background: Process Analysis DSM AKZO Nobel Chemicals Aspenpharma 2016: Sales Engineer Elscolab
More informationThe Elzone II Particle Count and Size Analyzer
The Elzone II 5390 Particle Count and Size Analyzer Elzone II Overview of Basic Theory Operates using the Electrical Sensing Zone (ESZ) Principle, also known as the Coulter Principle. First commercially
More informationMeasuring ph with Smart Cuvettes
1 Measuring ph with Smart Cuvettes Hardware Setup for ph Measurements ph is measured in Absorbance mode. Configure your spectroscopy components for Absorbance measurements. Sample Absorbance setups for
More information