CHARACTERIZATION OF Pu-CONTAINING PARTICLES BY X-RAY MICROFLUORESCENCE

Size: px
Start display at page:

Download "CHARACTERIZATION OF Pu-CONTAINING PARTICLES BY X-RAY MICROFLUORESCENCE"

Transcription

1 Copyright(c)JCPDS-International Centre for Diffraction Data 2000,Advances in X-ray Analysis,Vol CHARACTERIZATION OF Pu-CONTAINING PARTICLES BY X-RAY MICROFLUORESCENCE Marco Mattiuzzi, Andrzej Markowicz, Piero Danesi IAEA Laboratories Seibersdorf A-2444 Seibersdorf, Austria Abstract Pu-containing particles were collected in the Mururoa Atoll at "Safety Trial Test" sites by staff of the International Atomic Energy Agency (IAEA) and other experts. Several particles in the diameter range of µm were first characterized by optical microscopy followed by qualitative and semi-quantitative analysis performed by X-ray microfluorescence technique (µxrf). The elemental distributions for selected elements are also presented. The composition varies greatly not only from particle to particle but also within the same particle indicating a high degree of heterogeneity. The concentrations of Pu range from a few percent to some ppm while other actinide elements, like U and Np, are present at lower concentrations. Other elements, mainly metallic, were also identified at the concentration level of ppm. The elemental maps presented in the paper show the heterogeneous distributions of the elements and correlations between different elemental distributions are observed. The semi-quantitative results presented can be combined with a statistical classification procedure to identify the emitting sources when a limited number of samples are available for analysis. Introduction In June 1995 the IAEA was requested to assess the radiological consequences of the nuclear experiments carried out in the atolls of Mururoa and Fangataufa in French Polynesia. The results of the overall study have been reported in detail in reference [1]; the results of the terrestrial campaign have been described in vol. 1. In this work more detailed information on Pu containing hot particles collected at the safety trial test sites of the Mururoa atoll (the Colette region ) are reported. A safety trial is a test where the nuclear device core is detonated under simulated faulty conditions and little or no fission process takes place. The core is destroyed by the conventional explosive with the production of fine particles and fragments containing plutonium, which are widely dispersed if the test is not confined. Five out of 15 safety trials were conducted in the atmosphere between 1966 and 1974 at the northern tip of the Mururoa atoll. In these areas the soil consists of exposed bedrock, covered in some places by a thin layer of sand or coral debris. The areas are occasionally flooded by seawater. After these five tests the site was partially decontaminated with the aim of reducing 239 Pu activity to levels below 10 6 Bq/m 2, averaged over a 20x20 m 2 area. However, local higher Pu activities could still be found in the form of hot particles. Several sub-mm particles were isolated at the IAEA Seibersdorf Laboratories from samples of fine coral debris and loose coral pieces. Two single hot particles were identified locally and collected at the test sites. ten out of 20 hot particles separated from the collected materials were next characterized by using a µxrf technique with a spatial resolution of 15 µm. Data on the 10 particles are reported in Table 1.

2 This document was presented at the Denver X-ray Conference (DXC) on Applications of X-ray Analysis. Sponsored by the International Centre for Diffraction Data (ICDD). This document is provided by ICDD in cooperation with the authors and presenters of the DXC for the express purpose of educating the scientific community. All copyrights for the document are retained by ICDD. Usage is restricted for the purposes of education and scientific research. DXC Website ICDD Website -

3 Copyright(c)JCPDS-International Centre for Diffraction Data 2000,Advances in X-ray Analysis,Vol The characterization of individual radioactive particles is of great interest due to their importance in radiological studies as well as in the identification of emitting sources. The health risk associated to the presence of radioactive particles is related to the particle size and its bioavailabity. Information on the primary event that generated the particles such as fuel type, container alloy type and marine or terrestrial environment, can also be extracted. Due to their small sizes the identification, isolation and handling of these particles is rather difficult and usually only a limited number of samples can be available. Part. Code Size 239 Pu 241 Am 2Q IMG Part. Code Size 239 Pu 241 Am 2Q IMG x N Y x N Y x Y N x N Y 5 s/b x2/ Y N x N Y x Y Y x Y N x Y Y x Y N Table 1 Sub mm hot-particles from Mururoa Atoll isolated at the IAEA Laboratories, Seibersdorf. Columns 1 and 2 include the particle number and the sample code, see [1] for details. In column 3 approximate size (x100 µm) is shown. Columns 4 and 5 report the activities in kbq of respective radionuclides. In the sixth and seventh columns the type of analysis is reported (2Q = Qualit/Quanti-tative, IMG = elemental distribution, Y=yes, N=no). #4 #5s #5b #6 #8 #17 #18 Figure 1 Optical microscopic images of selected hot particles from the Mururoa Atoll. A different scale for displaying the particle bitmap images is used. Samples and measurements The particles were identified by a NaI probe after having distributed the collected material (coral soil) on a tray as a thin layer. The particles were then collected on the sticky side of an adhesive tape. The samples were divided into two sets, including single or multiple particles, respectively. The single particles were covered with a Mylar foil preventing the samples from falling off and next mounted on a sample holder. Some optical microscopy images acquired with a x5 magnification are reported in Figure 1. It is seen that particles #4, #8 and #18 have a relatively smooth surface and seem to be solid entities whereas particles #5, #6 and #17 are rough and morphologically heterogeneous. The µxrf measurements were performed by using the set-up available at the Seibersdorf IAEA Laboratories [2]. A Si-Li detector with 165 ev resolution (FWHM) at 5.9 kev was used to detect the characteristic X-rays. The beam detector angle was set at 35 o and the sample-detector distance was 15 mm. The X-ray source consisted of a Mo-anode X-ray tube operated at 50 kv and 30 ma combined with a 10 µm focusing monocapillary. The beam size was 15 µm at a sample-end capillary distance of approximately 2 mm. In order to obtain quali/quanti-tative information (2Q) and accurate imaging (IMG) of the elemental distribution two different measurements were performed.

4 Copyright(c)JCPDS-International Centre for Diffraction Data 2000,Advances in X-ray Analysis,Vol First, 121 pixels in an 11x11 grid were scanned with 600 s measuring time per pixel. The spectra were saved for the individual pixels for off-line analysis. By running the AXIL software package the characteristic X-ray intensities for various elements were calculated on a pixel basis. The following two criteria were then applied to eliminate the net intensities which were statistically insignificant: CTS < 3 BCK and Err CTS > 0.3CTS, where CTS and BCK are the intensities (in counts) of the characteristic X-ray peak and the background respectively, Err CTS is the uncertainty of the net intensity CTS associated with counting statistics and fitting procedure. The rectangular scan area containing the particle was determined by a pre-scan run. The pixels were then defined to be on the particle if more than two elements were identified. To generate high resolution elemental distributions maps up to128x128 pixels (depending on particle size) were investigated with a measuring time per pixel as low as 1 s. During these measurements the characteristic X-ray intensities were mapped, by using the SPECTOR software recently developed for the elemental micro X-ray imaging [3]. The software stores on-line the integral counts I ROI for the selected spectral regions (ROI). For each ROI a 2D (bit-) map is sequentially updated with I ROI for different X and Y coordinate on the sample. The map color scale is adjusted for each ROI to the maximum I ROI accordingly. Part. Quanti Quali 4 Cl-Ca-Fe-Ga-Sr-Pb-U-Np-Pu Ti-Cu-Zn-Am-Ni 5s Cl-Ca-Ti-Mn-Fe-Ni-Cu-Zn-Ga-Sr-Pb-U-Np-Pu Am-Pt 5b Cl-Ca-Ti-Cr-Mn-Fe-Ni-Cu-Zn-Ga-Sr-Pb-U-Np-Pu Si-Am-Th 6 Ca-Ti-Cr-Mn-Fe-Co-Ni-Cu-Zn-Ga-Sr-Pt-Pb-U-Np-Pu 8 Ca-Fe-Sr-Ra-U-Np-Pu Ba-Bi-Po-Pb 17 Cl-Ca-Cr-Mn-Fe-Ni-Zn-Ga-U-Pu Np-Th-Pt-Pb 18 Cl-Ca-Cr-Mn-Fe-Co-Ni-Ga-Br-Sr-U-Np-Pu Zn-Ti-Cu-Pb Table 2 Elements identified in at least one pixel for the particles specified in first column (see text for details) Qualitative & (semi-) quantitative results The results of the elemental identification for the elements with atomic number Z > 12 are reported in Table 2. The Quanti and Quali columns include all the elements that were identified in at least one pixel on the particle and for which quantitative and qualitative results were obtained. The calibration for the quantitative analysis, for both K and L characteristic lines, was performed by measuring certified pure element standards (9 pixels measured, 60 s measuring time per pixels). The sensitivity factors were determined for each element similarly to conventional XRF analysis. A usual correction for the matrix absorption effect (based on the geometry of the measurements, excitation energy and tabulated mass absorption coefficients) for the thick calibration samples was applied. The average sensitivity S avg was then calculated for each calibration element, and a relationship between S avg and the atomic number Z was established to perform quantitative analysis for other elements which are not included in the calibration process. The X-ray intensities I Z for the hot particles, stored on a pixel basis, were converted into the concentration C Z by using CZ = IZ FZ Savg (Z) where F Z is the absorption correction factor calculated by using AXIL tools with the assumption that the particle is a thick sample consisting of a uniform matrix of CaCO 3 (98%) + Fe(1%) + Pu(1%). Corrections for sample roughness and sample geometry were not taken into account. The quantitative results are summarized in Table 3.

5 Copyright(c)JCPDS-International Centre for Diffraction Data 2000,Advances in X-ray Analysis,Vol Part. El. Avg. Max. Min. Part. El. Avg. Max. Min. 4 Cl 1E+1 2E+1 3E+0 17 Zn 7E-1 6E+0 2E-1 5s Cl 9E+0 3E+1 2E+0 5s Zn 5E-1 3E+0 3E-3 17 Cl 6E+0 1E+1 3E+0 5b Zn 3E-1 2E+0 3E-3 5b Cl 5E+0 2E+1 2E+0 6 Zn 1E-1 4E-1 6E-2 18 Cl 2E-1 4E-1 8E-2 4 Ga 1E-1 3E-1 4E-3 18 Ca 1E+1 5E+1 1E-1 5s Ga 5E-2 2E-1 4E-3 4 Ca 1E+1 5E+1 4E-1 17 Ga 3E-2 1E-1 3E-3 5b Ca 1E+1 6E+1 5E-1 5b Ga 2E-2 7E-2 3E-3 5s Ca 1E+1 3E+1 5E-1 18 Ga 2E-2 6E-2 8E-3 6 Ca 9E+0 5E+1 6E-1 6 Ga 2E-2 4E-2 2E-3 17 Ca 7E+0 2E+1 5E-1 18 Br 2E-2 3E-2 8E-3 8 Ca 2E+0 4E+0 3E-1 18 Sr 5E+0 1E+1 7E-2 5s Ti 4E-1 7E-1 1E-1 4 Sr 1E+0 3E+0 1E-1 6 Ti 4E-1 1E+0 1E-1 8 Sr 5E-1 4E+0 1E-2 5b Ti 3E-1 5E-1 1E-1 5s Sr 2E-1 2E+0 4E-3 18 Cr 4E-1 2E+0 1E-1 6 Sr 2E-1 1E+0 1E-2 17 Cr 4E-1 9E-1 6E-2 5b Sr 8E-2 5E-1 4E-3 5b Cr 2E-1 6E-1 3E-2 4 Pb 2E-2 3E-2 6E-3 6 Cr 1E-1 3E-1 4E-2 5s Pb 4E-3 1E-2 2E-3 18 Mn 2E-1 5E-1 1E-1 5b Pb 3E-3 5E-3 1E-3 17 Mn 1E-1 3E-1 2E-2 8 Ra 1E-2 7E-2 2E-3 6 Mn 9E-2 3E-1 3E-2 17 U 7E-2 2E-1 2E-3 5s Mn 8E-2 2E-1 3E-2 6 U 5E-2 3E-1 1E-3 5b Mn 8E-2 2E-1 4E-2 18 U 3E-2 7E-2 8E-3 18 Fe 5E+0 3E+1 6E-2 4 U 2E-2 3E-2 3E-3 6 Fe 4E+0 4E+1 2E-2 5s U 2E-2 4E-2 2E-3 17 Fe 2E+0 1E+1 4E-2 5b U 1E-2 2E-2 2E-3 5s Fe 2E+0 5E+0 9E-3 8 U 9E-3 2E-2 2E-3 5b Fe 1E+0 5E+0 1E-2 4 Np 6E-2 1E-1 4E-3 4 Fe 4E-1 9E-1 6E-2 5s Np 2E-2 1E-1 4E-3 8 Fe 3E-2 7E-2 2E-2 18 Np 2E-2 4E-2 6E-3 18 Co 6E-2 1E-1 4E-2 8 Np 2E-2 1E-1 2E-3 6 Co 4E-2 1E-1 1E-2 5b Np 1E-2 4E-2 4E-3 18 Ni 1E-1 4E-1 2E-2 6 Np 5E-3 9E-3 2E-3 17 Ni 7E-2 2E-1 6E-3 4 Pu 1E+0 4E+0 9E-3 5s Ni 4E-2 9E-2 7E-3 5s Pu 4E-1 3E+0 7E-3 5b Ni 4E-2 1E-1 5E-3 17 Pu 4E-1 2E+0 5E-3 6 Ni 4E-2 1E-1 5E-3 8 Pu 3E-1 2E+0 2E-3 6 Cu 2E-1 7E-1 1E-1 18 Pu 2E-1 1E+0 6E-3 5s Cu 6E-2 2E-1 4E-3 5b Pu 1E-1 1E+0 5E-3 5b Cu 5E-2 2E-1 3E-3 6 Pu 1E-1 4E-1 1E-3 Table 3 Average, maximum and minimum concentrations in % (columns Avg., Max., Min ) for different elements ( El ) in the different particles Figure 2 Elemental distributions of selected elements for particle #6. The scan area corresponds to 1.4x1.4 mm 2 with a 128x128 pixel resolution.

6 Copyright(c)JCPDS-International Centre for Diffraction Data 2000,Advances in X-ray Analysis,Vol The concentration (Avg.) of an element was calculated as the average value of the results obtained for all the pixels where that element was identified. The maximum and minimum concentrations for the individual pixels are also reported. Due to the uncertainties in the calibration, matrix composition and the absorption correction factor for the real (non-flat) sample, the concentrations given in Table 3 can vary within a factor of 3. Figure 3 Elemental distributions for selected elements in particle #2. The scan area corresponds to 1.1x1.1 mm 2 with 75x75 pixel resolution. Imaging of the elemental distributions At microscopic scale the local composition of these particles varies due to their intrinsic heterogeneity. Scanning the sample with a microbeam results in the elemental distributions represented by the plots of the intensities of the characteristic X-rays as a function of the sample coordinate. Based on the elemental distributions the correlation between the elements can also be identified. Some examples are given in Figure 2 where selected elements are mapped and the correlation between them can be seen, as in the case of Ca-Sr, Cr-Ni or Zn-U-Pu. Other interesting features can be observed for Fe (highly concentrated in one spot), Cu (mainly coming as tiny clusters) or Pb (widely spread all over the particle). Similar features are seen in Figure 3 where selected elemental distributions for particle #2 are presented. Zn is present in one small spot only, U and Pu have totally different distributions (U mainly concentrated in one location at the bottom of the particle with Pu distributed rather homogeneously in the whole particle). It is worth mentioning that the Geometry Figure 4 Examples of Absorption, Matrix variation and Geometry patterns in sub-mm particle scanning (see text for details). different effects related to absorption, matrix variation and geometry influence the elemental images shown in Figs 2 and 3. Accounting for these effects would result in elemental distributions that are closer to the actual distributions and would provide a possibility to perform a more accurate quantitative analysis. The absorption effect can be accounted for by plotting the intensity ratio for the characteristic X-ray lines of the same element. This

7 Copyright(c)JCPDS-International Centre for Diffraction Data 2000,Advances in X-ray Analysis,Vol effect can be seen in Figure 4 (Abs) where the ratio of Pu-L β / Pu-M α is presented; in the absorption pattern, according to the color scale shown on the right, the places indicated by dark blue are characterized by the weakest absorption. The matrix variation effect is shown in Figure 4 (Matr.) where the coherently scattered primary photon beam is mapped (since the coherent scattering depends strongly on the atomic number, matrix variations are clearly seen). The geometry effect is related to the geometry of the µxrf set-up. For non-flat samples the characteristic radiation is locally self-shadowed by the sample. In Figure 4 (Geometry) the effect for the rather uniform (in terms of matrix) particle #8 is shown. The left part of the Pu-M α distribution is missing as the detector is positioned at right angles relative to the beam. The estimation of these (interrelated) effects would give the possibility to obtain more accurate elemental concentrations and their distributions. Discussion and Conclusions The characterization of the sub-mm particles was performed by using a µxrf set-up. Several particles were analyzed and both qualitative and (semi-) quantitative results were obtained for many elements (up to 18). Based on the results some information on: i) the environment where the particles were collected (marine, presence of Cl, Ca and Sr at % concentration level), ii) the composition of metal container used for exploding the device (presence of the elements of the container alloy such as Cr, Mn, Fe, Ni, Cu and Zn at concentration level below %), and iii) the original test material (Pu, U and Np at the concentration level from % down to some hundreds ppm in case of Pu and at lower concentration level for other elements), were obtained. The particle s composition varied very much not only for the different samples but also within the same sample; for some elements in an individual particle the concentration range was as wide as three orders of magnitude. The imaging of elemental distribution showed the correlation between the elements and confirmed a high degree of heterogeneity in the elemental composition. These results confirm that µxrf can provide valuable data for the characterization of sub-mm heterogeneous samples where the concentrations of the elements are as low as a few tens ppm. To perform a classification of the particles in terms of geographical origin and other characteristics the investigation at microscopic level can be combined with a statistical classification procedure, such as principal component or cluster analysis. Acknowledgments: The authors are grateful to Mr. M. Makarewicz and to the staff of Chemistry Unit, IAEA Seibersdorf Laboratories, for providing the samples. REFERENCES [1] The Radiological Situation at the Atoll of Mururoa and Fangataufa, Radiological Assessment Report Series, ISBN ISSN , volumes 1 to 6, STI/PUB 1028, IAEA, Vienna 1998 [2] G. Bernasconi, N. Haselberger, A. Markowicz and V. Valkovic, Nucl. Inst. and Meth. B 86(1994)333 [3] M. Bogovac, M. Mattiuzzi, in preparation, 1999

A MODIFIED APPROACH TO HOMOGENEITY TESTING AT MICROSCALE

A MODIFIED APPROACH TO HOMOGENEITY TESTING AT MICROSCALE Copyright(C)JCPDS-International Centre for Diffraction Data 2000, Advances in X-ray Analysis, Vol.42 74 Copyright(C)JCPDS-International Centre for Diffraction Data 2000, Advances in X-ray Analysis, Vol.42

More information

Peter L Warren, Pamela Y Shadforth ICI Technology, Wilton, Middlesbrough, U.K.

Peter L Warren, Pamela Y Shadforth ICI Technology, Wilton, Middlesbrough, U.K. 783 SCOPE AND LIMITATIONS XRF ANALYSIS FOR SEMI-QUANTITATIVE Introduction Peter L Warren, Pamela Y Shadforth ICI Technology, Wilton, Middlesbrough, U.K. Historically x-ray fluorescence spectrometry has

More information

APPLICATION OF MICRO X-RAY FLUORESCENCE SPECTROMETRY FOR LOCALIZED AREA ANALYSIS OF BIOLOGICAL AND ENVIRONMENTAL MATERIALS

APPLICATION OF MICRO X-RAY FLUORESCENCE SPECTROMETRY FOR LOCALIZED AREA ANALYSIS OF BIOLOGICAL AND ENVIRONMENTAL MATERIALS Copyright(c)JCPDS-International Centre for Diffraction Data 2000,Advances in X-ray Analysis,Vol.43 540 APPLICATION OF MICRO X-RAY FLUORESCENCE SPECTROMETRY FOR LOCALIZED AREA ANALYSIS OF BIOLOGICAL AND

More information

MT Electron microscopy Scanning electron microscopy and electron probe microanalysis

MT Electron microscopy Scanning electron microscopy and electron probe microanalysis MT-0.6026 Electron microscopy Scanning electron microscopy and electron probe microanalysis Eero Haimi Research Manager Outline 1. Introduction Basics of scanning electron microscopy (SEM) and electron

More information

RADIOACTIVE SAMPLE EFFECTS ON EDXRF SPECTRA

RADIOACTIVE SAMPLE EFFECTS ON EDXRF SPECTRA 90 RADIOACTIVE SAMPLE EFFECTS ON EDXRF SPECTRA Christopher G. Worley Los Alamos National Laboratory, MS G740, Los Alamos, NM 87545 ABSTRACT Energy dispersive X-ray fluorescence (EDXRF) is a rapid, straightforward

More information

CALCULATION METHODS OF X-RAY SPECTRA: A COMPARATIVE STUDY

CALCULATION METHODS OF X-RAY SPECTRA: A COMPARATIVE STUDY Copyright -International Centre for Diffraction Data 2010 ISSN 1097-0002 CALCULATION METHODS OF X-RAY SPECTRA: A COMPARATIVE STUDY B. Chyba, M. Mantler, H. Ebel, R. Svagera Technische Universit Vienna,

More information

DEVELOPMENT OF A NEW POSITRON LIFETIME SPECTROSCOPY TECHNIQUE FOR DEFECT CHARACTERIZATION IN THICK MATERIALS

DEVELOPMENT OF A NEW POSITRON LIFETIME SPECTROSCOPY TECHNIQUE FOR DEFECT CHARACTERIZATION IN THICK MATERIALS Copyright JCPDS - International Centre for Diffraction Data 2004, Advances in X-ray Analysis, Volume 47. 59 DEVELOPMENT OF A NEW POSITRON LIFETIME SPECTROSCOPY TECHNIQUE FOR DEFECT CHARACTERIZATION IN

More information

A COMPACT X-RAY SPECTROMETER WITH MULTI-CAPILLARY X-RAY LENS AND FLAT CRYSTALS

A COMPACT X-RAY SPECTROMETER WITH MULTI-CAPILLARY X-RAY LENS AND FLAT CRYSTALS Copyright(c)JCPDS-International Centre for Diffraction Data 2001,Advances in X-ray Analysis,Vol.44 320 A COMPACT X-RAY SPECTROMETER WITH MULTI-CAPILLARY X-RAY LENS AND FLAT CRYSTALS Hiroyoshi SOEJIMA and

More information

FUNDAMENTAL PARAMETER METHOD USING SCATTERING X-RAYS IN X-RAY FLUORESCENCE ANALYSIS

FUNDAMENTAL PARAMETER METHOD USING SCATTERING X-RAYS IN X-RAY FLUORESCENCE ANALYSIS FUNDAMENTAL PARAMETER METHOD USING SCATTERING X-RAYS IN X-RAY FLUORESCENCE ANALYSIS 255 Yoshiyuki Kataoka 1, Naoki Kawahara 1, Shinya Hara 1, Yasujiro Yamada 1, Takashi Matsuo 1, Michael Mantler 2 1 Rigaku

More information

LASER-COMPTON SCATTERING AS A POTENTIAL BRIGHT X-RAY SOURCE

LASER-COMPTON SCATTERING AS A POTENTIAL BRIGHT X-RAY SOURCE Copyright(C)JCPDS-International Centre for Diffraction Data 2003, Advances in X-ray Analysis, Vol.46 74 ISSN 1097-0002 LASER-COMPTON SCATTERING AS A POTENTIAL BRIGHT X-RAY SOURCE K. Chouffani 1, D. Wells

More information

Time-Resolved μ-xrf and Elemental Mapping of Biological Materials

Time-Resolved μ-xrf and Elemental Mapping of Biological Materials 296 Time-Resolved μ-xrf and Elemental Mapping of Biological Materials K. Tsuji 1,2), K. Tsutsumimoto 1), K. Nakano 1,2), K. Tanaka 1), A. Okhrimovskyy 1), Y. Konishi 1), and X. Ding 3) 1) Department of

More information

PERFORMANCE OF A ROOM TEMPERATURE GAS PROPORTIONAL SCINTILLATION COUNTER IN X-RAY ANALYSIS OF METALLIC ALLOYS EXCITED WITH ALPHA PARTICLES

PERFORMANCE OF A ROOM TEMPERATURE GAS PROPORTIONAL SCINTILLATION COUNTER IN X-RAY ANALYSIS OF METALLIC ALLOYS EXCITED WITH ALPHA PARTICLES 249 PERFORMANCE OF A ROOM TEMPERATURE GAS PROPORTIONAL SCINTILLATION COUNTER IN X-RAY ANALYSIS OF METALLIC ALLOYS EXCITED WITH ALPHA PARTICLES F. I. G. M. Borges, S. J. C. do Carmo, T. H. V. T. Dias, F.

More information

Developments & Limitations in GSR Analysis

Developments & Limitations in GSR Analysis Developments & Limitations in GSR Analysis ENFSI Working Group Meeting June 2006 Jenny Goulden Oxford Instruments NanoAnalysis Overview Introduction Developments in GSR Software Importance of EDS Hardware

More information

GLANCING INCIDENCE XRF FOR THE ANALYSIS OF EARLY CHINESE BRONZE MIRRORS

GLANCING INCIDENCE XRF FOR THE ANALYSIS OF EARLY CHINESE BRONZE MIRRORS 176 177 GLANCING INCIDENCE XRF FOR THE ANALYSIS OF EARLY CHINESE BRONZE MIRRORS Robert W. Zuneska, Y. Rong, Isaac Vander, and F. J. Cadieu* Physics Dept., Queens College of CUNY, Flushing, NY 11367. ABSTRACT

More information

ACCURATE QUANTIFICATION OF RADIOACTIVE MATERIALS BY X-RAY FLUORESCENCE: GALLIUM IN PLUTONIUM METAL

ACCURATE QUANTIFICATION OF RADIOACTIVE MATERIALS BY X-RAY FLUORESCENCE: GALLIUM IN PLUTONIUM METAL Copyright JCPDS - International Centre for Diffraction Data 2003, Advances in X-ray Analysis, Volume 46. 369 ACCURATE QUANTIFICATION OF RADIOACTIVE MATERIALS BY X-RAY FLUORESCENCE: GALLIUM IN PLUTONIUM

More information

AEROSOL FILTER ANALYSIS USING POLARIZED OPTICS EDXRF WITH THIN FILM FP METHOD

AEROSOL FILTER ANALYSIS USING POLARIZED OPTICS EDXRF WITH THIN FILM FP METHOD Copyright JCPDS-International Centre for Diffraction Data 2014 ISSN 1097-0002 219 AEROSOL FILTER ANALYSIS USING POLARIZED OPTICS EDXRF WITH THIN FILM FP METHOD Takao Moriyama 1), Atsushi Morikawa 1), Makoto

More information

MS482 Materials Characterization ( 재료분석 ) Lecture Note 4: XRF

MS482 Materials Characterization ( 재료분석 ) Lecture Note 4: XRF 2016 Fall Semester MS482 Materials Characterization ( 재료분석 ) Lecture Note 4: XRF Byungha Shin Dept. of MSE, KAIST 1 Course Information Syllabus 1. Overview of various characterization techniques (1 lecture)

More information

NEW CORRECTION PROCEDURE FOR X-RAY SPECTROSCOPIC FLUORESCENCE DATA: SIMULATIONS AND EXPERIMENT

NEW CORRECTION PROCEDURE FOR X-RAY SPECTROSCOPIC FLUORESCENCE DATA: SIMULATIONS AND EXPERIMENT Copyright JCPDS - International Centre for Diffraction Data 2005, Advances in X-ray Analysis, Volume 48. 266 NEW CORRECTION PROCEDURE FOR X-RAY SPECTROSCOPIC FLUORESCENCE DATA: SIMULATIONS AND EXPERIMENT

More information

FUNDAMENTAL PARAMETERS ANALYSIS OF ROHS ELEMENTS IN PLASTICS

FUNDAMENTAL PARAMETERS ANALYSIS OF ROHS ELEMENTS IN PLASTICS 45 ABSTRACT FUNDAMENTAL PARAMETERS ANALYSIS OF ROHS ELEMENTS IN PLASTICS W. T. Elam, Robert B. Shen, Bruce Scruggs, and Joseph A. Nicolosi EDAX, Inc. Mahwah, NJ 70430 European Community Directive 2002/95/EC

More information

Latest advances in identifying mineral composition variation by the M4 TORNADO AMICS

Latest advances in identifying mineral composition variation by the M4 TORNADO AMICS Latest advances in identifying mineral composition variation by the M4 TORNADO AMICS Bruker Nano Analytics, Berlin, Germany Webinar, June 15, 2017 Innovation with Integrity Presenters Samuel Scheller Sr.

More information

USABILITY OF PORTABLE X-RAY SPECTROMETER FOR DISCRIMINATION OF VALENCE STATES

USABILITY OF PORTABLE X-RAY SPECTROMETER FOR DISCRIMINATION OF VALENCE STATES Copyright (c)jcpds-international Centre for Diffraction Data 00, Advances in X-ray Analysis, Volume 45. 409 ISSN 1097-000 USABIITY OF POTABE X-AY SPECTOMETE FO DISCIMINATION OF VAENCE STATES I.A.Brytov,.I.Plotnikov,B.D.Kalinin,

More information

Overview of X-Ray Fluorescence Analysis

Overview of X-Ray Fluorescence Analysis Overview of X-Ray Fluorescence Analysis AMPTEK, INC., Bedford, MA 01730 Ph: +1 781 275 2242 Fax: +1 781 275 3470 sales@amptek.com 1 What is X-Ray Fluorescence (XRF)? A physical process: Emission of characteristic

More information

TRACE ELEMENT ANALYSIS USING A BENCHTOP TXRF- SPECTROMETER

TRACE ELEMENT ANALYSIS USING A BENCHTOP TXRF- SPECTROMETER Copyright JCPDS - International Centre for Diffraction Data 2005, Advances in X-ray Analysis, Volume 48. 236 ABSTRACT TRACE ELEMENT ANALYSIS USING A BENCHTOP TXRF- SPECTROMETER Hagen Stosnach Röntec GmbH,

More information

International Atomic Energy Agency. Department of Nuclear Sciences and Applications. IAEA Environment Laboratories

International Atomic Energy Agency. Department of Nuclear Sciences and Applications. IAEA Environment Laboratories International Atomic Energy Agency Department of Nuclear Sciences and Applications IAEA Environment Laboratories Vienna International Centre, P.O. Box 100, 1400 Vienna, Austria REFERENCE SHEET CERTIFIED

More information

ADVANTAGES AND DISADVANTAGES OF BAYESIAN METHODS FOR OBTAINING XRF NET INTENSITIES

ADVANTAGES AND DISADVANTAGES OF BAYESIAN METHODS FOR OBTAINING XRF NET INTENSITIES 187 188 ADVANTAGES AND DISADVANTAGES OF BAYESIAN METHODS FOR OBTAINING XRF NET INTENSITIES ABSTRACT W. T. Elam, B. Scruggs, F. Eggert, and J. A. Nicolosi EDAX, a unit of Ametek Inc., 91 McKee Drive, Mahwah,

More information

THE IMPORTANCE OF THE SPECIMEN DISPLACEMENT CORRECTION IN RIETVELD PATTERN FITTING WITH SYMMETRIC REFLECTION-OPTICS DIFFRACTION DATA

THE IMPORTANCE OF THE SPECIMEN DISPLACEMENT CORRECTION IN RIETVELD PATTERN FITTING WITH SYMMETRIC REFLECTION-OPTICS DIFFRACTION DATA Copyright(c)JCPDS-International Centre for Diffraction Data 2001,Advances in X-ray Analysis,Vol.44 96 THE IMPORTANCE OF THE SPECIMEN DISPLACEMENT CORRECTION IN RIETVELD PATTERN FITTING WITH SYMMETRIC REFLECTION-OPTICS

More information

BENEFITS OF IMPROVED RESOLUTION FOR EDXRF

BENEFITS OF IMPROVED RESOLUTION FOR EDXRF 135 Abstract BENEFITS OF IMPROVED RESOLUTION FOR EDXRF R. Redus 1, T. Pantazis 1, J. Pantazis 1, A. Huber 1, B. Cross 2 1 Amptek, Inc., 14 DeAngelo Dr, Bedford MA 01730, 781-275-2242, www.amptek.com 2

More information

XRD RAPID SCREENING SYSTEM FOR COMBINATORIAL CHEMISTRY

XRD RAPID SCREENING SYSTEM FOR COMBINATORIAL CHEMISTRY Copyright(c)JCPDS-International Centre for Diffraction Data 2001,Advances in X-ray Analysis,Vol.44 1 XRD RAPID SCREENING SYSTEM FOR COMBINATORIAL CHEMISTRY Bob B. He, John Anzelmo, Peter LaPuma, Uwe Preckwinkel,

More information

CHARACTERIZING PROCESS SEMICONDUCTOR THIN FILMS WITH A CONFOCAL MICRO X-RAY FLUORESCENCE MICROSCOPE

CHARACTERIZING PROCESS SEMICONDUCTOR THIN FILMS WITH A CONFOCAL MICRO X-RAY FLUORESCENCE MICROSCOPE CHARACTERIZING PROCESS SEMICONDUCTOR THIN FILMS WITH A CONFOCAL MICRO X-RAY FLUORESCENCE MICROSCOPE 218 Chris M. Sparks 1, Elizabeth P. Hastings 2, George J. Havrilla 2, and Michael Beckstead 2 1. ATDF,

More information

Horst Ebel, Robert Svagera, Christian Hager, Maria F.Ebel, Christian Eisenmenger-Sittner, Johann Wernisch, and Michael Mantler

Horst Ebel, Robert Svagera, Christian Hager, Maria F.Ebel, Christian Eisenmenger-Sittner, Johann Wernisch, and Michael Mantler DETECTION OF SUBMONOLAYERS BY MEASUREMENT OF THE TOTAL ELECTRON YIELD (TEY) OF X-RAY EXCITED ELECTRON EMISSION Horst Ebel, Robert Svagera, Christian Hager, Maria F.Ebel, Christian Eisenmenger-Sittner,

More information

X-Ray Fluorescence and Natural History

X-Ray Fluorescence and Natural History X-Ray Fluorescence and Natural History How XRF Helps XRF can be used both quantitatively (homogenous samples) and quantitatively (heterogenous samples).! Trace elements in a fossil can help identify source,

More information

Data report for elemental analysis of IMPROVE samples collected during April, May, June 2009 UC Davis Submitted June 18, 2010 SUMMARY

Data report for elemental analysis of IMPROVE samples collected during April, May, June 2009 UC Davis Submitted June 18, 2010 SUMMARY Data report for elemental analysis of IMPROVE samples collected during April, May, June 2009 UC Davis Submitted June 8, 200 SUMMARY This report summarizes the quality assurance performed during elemental

More information

FACTORS AFFECTING IN-LINE PHASE CONTRAST IMAGING WITH A LABORATORY MICROFOCUS X-RAY SOURCE

FACTORS AFFECTING IN-LINE PHASE CONTRAST IMAGING WITH A LABORATORY MICROFOCUS X-RAY SOURCE Copyright JCPDS-International Centre for Diffraction Data 26 ISSN 197-2 FACTORS AFFECTING IN-LINE PHASE CONTRAST IMAGING WITH A LABORATORY MICROFOCUS X-RAY SOURCE 31 K. L. Kelly and B. K. Tanner Department

More information

Altitude influence of elemental distribution in grass from Rila mountain. Dr. E. Nikolova, Dr. A. Artinyan, S. Nikolova INRNE - BAS XRF Laboratory

Altitude influence of elemental distribution in grass from Rila mountain. Dr. E. Nikolova, Dr. A. Artinyan, S. Nikolova INRNE - BAS XRF Laboratory Altitude influence of elemental distribution in grass from Rila mountain Dr. E. Nikolova, Dr. A. Artinyan, S. Nikolova INRNE - BAS XRF Laboratory I. Introduction The application of modern instrumental

More information

INFLUENCE OF GROWTH INTERRUPTION ON THE FORMATION OF SOLID-STATE INTERFACES

INFLUENCE OF GROWTH INTERRUPTION ON THE FORMATION OF SOLID-STATE INTERFACES 122 INFLUENCE OF GROWTH INTERRUPTION ON THE FORMATION OF SOLID-STATE INTERFACES I. Busch 1, M. Krumrey 2 and J. Stümpel 1 1 Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany

More information

MICRO-TOMOGRAPHY AND X-RAY ANALYSIS OF GEOLOGICAL SAMPLES

MICRO-TOMOGRAPHY AND X-RAY ANALYSIS OF GEOLOGICAL SAMPLES THE PUBLISHING HOUSE PROCEEDINGS OF THE ROMANIAN ACADEMY, Series A, OF THE ROMANIAN ACADEMY Volume 18, Number 1/2017, pp. 42 49 MICRO-TOMOGRAPHY AND X-RAY ANALYSIS OF GEOLOGICAL SAMPLES Ion GRUIA University

More information

1 of 5 14/10/ :21

1 of 5 14/10/ :21 X-ray absorption s, characteristic X-ray lines... 4.2.1 Home About Table of Contents Advanced Search Copyright Feedback Privacy You are here: Chapter: 4 Atomic and nuclear physics Section: 4.2 Absorption

More information

IMPROVING THE ACCURACY OF RIETVELD-DERIVED LATTICE PARAMETERS BY AN ORDER OF MAGNITUDE

IMPROVING THE ACCURACY OF RIETVELD-DERIVED LATTICE PARAMETERS BY AN ORDER OF MAGNITUDE Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume 45. 158 IMPROVING THE ACCURACY OF RIETVELD-DERIVED LATTICE PARAMETERS BY AN ORDER OF MAGNITUDE B. H.

More information

IAEA-SM-367/10/04/P SCREENING AND RADIOMETRIC MEASUREMENT OF ENVIRONMENTAL SWIPE SAMPLES

IAEA-SM-367/10/04/P SCREENING AND RADIOMETRIC MEASUREMENT OF ENVIRONMENTAL SWIPE SAMPLES IAEA-SM-367/10/04/P SCREENING AND RADIOMETRIC MEASUREMENT OF ENVIRONMENTAL SWIPE SAMPLES V. MAIOROV, A. CIURAPINSKI, W. RAAB and V. JANSTA Safeguards Analytical Laboratory, International Atomic Energy

More information

ABNORMAL X-RAY EMISSION FROM INSULATORS BOMBARDED WITH LOW ENERGY IONS

ABNORMAL X-RAY EMISSION FROM INSULATORS BOMBARDED WITH LOW ENERGY IONS 302 ABNORMAL X-RAY EMISSION FROM INSULATORS BOMBARDED WITH LOW ENERGY IONS M. Song 1, K. Mitsuishi 1, M. Takeguchi 1, K. Furuya 1, R. C. Birtcher 2 1 High Voltage Electron Microscopy Station, National

More information

Quantitative XRF Analysis. algorithms and their practical use

Quantitative XRF Analysis. algorithms and their practical use Joint ICTP-IAEA School on Novel Experimental Methodologies for Synchrotron Radiation Applications in Nano-science and Environmental Monitoring Quantitative XRF Analysis algorithms and their practical use

More information

LAB REPORT ON XRF OF POTTERY SAMPLES By BIJOY KRISHNA HALDER Mohammad Arif Ishtiaque Shuvo Jie Hong

LAB REPORT ON XRF OF POTTERY SAMPLES By BIJOY KRISHNA HALDER Mohammad Arif Ishtiaque Shuvo Jie Hong LAB REPORT ON XRF OF POTTERY SAMPLES By BIJOY KRISHNA HALDER Mohammad Arif Ishtiaque Shuvo Jie Hong Introduction: X-ray fluorescence (XRF) spectrometer is an x-ray instrument used for routine, relatively

More information

EFFECT OF CALIBRATION SPECIMEN PREPARATION TECHNIQUES ON NARROW RANGE X-RAY FLUORESCENCE CALIBRATION ACCURACY

EFFECT OF CALIBRATION SPECIMEN PREPARATION TECHNIQUES ON NARROW RANGE X-RAY FLUORESCENCE CALIBRATION ACCURACY Copyright(c)JCPDS-International Centre for Diffraction Data 2000,Advances in X-ray Analysis,Vol.43 424 EFFECT OF CALIBRATION SPECIMEN PREPARATION TECHNIQUES ON NARROW RANGE X-RAY FLUORESCENCE CALIBRATION

More information

COMPARISON OF THREE UNIVERSAL CURVES FOR THE ESCAPE PROBABILITY OF X-RAY EXCITED ELECTRONS - I. THEORY

COMPARISON OF THREE UNIVERSAL CURVES FOR THE ESCAPE PROBABILITY OF X-RAY EXCITED ELECTRONS - I. THEORY Copyright(c)JCPDS-International Centre for Diffraction Data 2001,Advances in X-ray Analysis,Vol.44 380 COMPARISON OF THREE UNIVERSAL CURVES FOR THE ESCAPE PROBABILITY OF X-RAY EXCITED ELECTRONS - I. THEORY

More information

ED(P)XRF: SCREENING ANALYSIS AND QUANTITATIVE ANALYSIS with POLARIZED

ED(P)XRF: SCREENING ANALYSIS AND QUANTITATIVE ANALYSIS with POLARIZED 384 ED(P)XRF: SCREENING ANALYSIS AND QUANTITATIVE ANALYSIS with POLARIZED X-RAYS R. Schramm, J. Heckel, K. Molt 2 Spectra Analytical Instruments, Kleve, Germany. 2Gerhard-Mercator- University Duisburg,

More information

Auger Electron Spectroscopy Overview

Auger Electron Spectroscopy Overview Auger Electron Spectroscopy Overview Also known as: AES, Auger, SAM 1 Auger Electron Spectroscopy E KLL = E K - E L - E L AES Spectra of Cu EdN(E)/dE Auger Electron E N(E) x 5 E KLL Cu MNN Cu LMM E f E

More information

International Atomic Energy Agency. Department of Nuclear Sciences and Applications. IAEA Environment Laboratories

International Atomic Energy Agency. Department of Nuclear Sciences and Applications. IAEA Environment Laboratories International Atomic Energy Agency Department of Nuclear Sciences and Applications IAEA Environment Laboratories Vienna International Centre, P.O. Box 100, 1400 Vienna, Austria REFERENCE SHEET CERTIFIED

More information

STRESS ANALYSIS USING BREMSSTRAHLUNG RADIATION

STRESS ANALYSIS USING BREMSSTRAHLUNG RADIATION Copyright JCPDS - International Centre for Diffraction Data 2003, Advances in X-ray Analysis, Volume 46. 106 STRESS ANALYSIS USING BREMSSTRAHLUNG RADIATION F. A. Selim 1, D.P. Wells 1, J. F. Harmon 1,

More information

Electron probe microanalysis - Electron microprobe analysis EPMA (EMPA) What s EPMA all about? What can you learn?

Electron probe microanalysis - Electron microprobe analysis EPMA (EMPA) What s EPMA all about? What can you learn? Electron probe microanalysis - Electron microprobe analysis EPMA (EMPA) What s EPMA all about? What can you learn? EPMA - what is it? Precise and accurate quantitative chemical analyses of micron-size

More information

B. X : in phase; Y: out of phase C. X : out of phase; Y: in phase D. X : out of phase; Y: out of phase

B. X : in phase; Y: out of phase C. X : out of phase; Y: in phase D. X : out of phase; Y: out of phase 2015 April 24 Exam 3 Physics 106 Circle the letter of the single best answer. Each question is worth 1 point Physical Constants: proton charge = e = 1.60 10 19 C proton mass = m p = 1.67 10 27 kg electron

More information

SCIENTIFIC TEAMWORK. Shortly after the BY PIER ROBERTO DANESI AND PAVEL PETER POVINEC

SCIENTIFIC TEAMWORK. Shortly after the BY PIER ROBERTO DANESI AND PAVEL PETER POVINEC ANALYSIS OF RADIOACTIVITY IN THE ENVIRONMENT OF MURUROA & FANGATAUFA ATOLLS: THE IAEA LABORATORIES IN OPERATION SCIENTIFIC TEAMWORK BY PIER ROBERTO DANESI AND PAVEL PETER POVINEC 24 Shortly after the International

More information

ELECTRIC FIELD INFLUENCE ON EMISSION OF CHARACTERISTIC X-RAY FROM Al 2 O 3 TARGETS BOMBARDED BY SLOW Xe + IONS

ELECTRIC FIELD INFLUENCE ON EMISSION OF CHARACTERISTIC X-RAY FROM Al 2 O 3 TARGETS BOMBARDED BY SLOW Xe + IONS 390 ELECTRIC FIELD INFLUENCE ON EMISSION OF CHARACTERISTIC X-RAY FROM Al 2 O 3 TARGETS BOMBARDED BY SLOW Xe + IONS J. C. Rao 1, 2 *, M. Song 2, K. Mitsuishi 2, M. Takeguchi 2, K. Furuya 2 1 Department

More information

ANALYSIS OF LOW MASS ABSORPTION MATERIALS USING GLANCING INCIDENCE X-RAY DIFFRACTION

ANALYSIS OF LOW MASS ABSORPTION MATERIALS USING GLANCING INCIDENCE X-RAY DIFFRACTION 173 ANALYSIS OF LOW MASS ABSORPTION MATERIALS USING GLANCING INCIDENCE X-RAY DIFFRACTION N. A. Raftery, L. K. Bekessy, and J. Bowpitt Faculty of Science, Queensland University of Technology, GPO Box 2434,

More information

International Atomic Energy Agency. Department of Nuclear Sciences and Applications. IAEA Environment Laboratories

International Atomic Energy Agency. Department of Nuclear Sciences and Applications. IAEA Environment Laboratories International Atomic Energy Agency Department of Nuclear Sciences and Applications IAEA Environment Laboratories Vienna International Centre, P.O. Box 100, 1400 Vienna, Austria REFERENCE SHEET CERTIFIED

More information

ULTRATHIN LAYER DEPOSITIONS A NEW TYPE OF REFERENCE SAMPLES FOR HIGH PERFORMANCE XRF ANALYSIS

ULTRATHIN LAYER DEPOSITIONS A NEW TYPE OF REFERENCE SAMPLES FOR HIGH PERFORMANCE XRF ANALYSIS 298 299 ULTRATHIN LAYER DEPOSITIONS A NEW TYPE OF REFERENCE SAMPLES FOR HIGH PERFORMANCE XRF ANALYSIS M. Krämer 1), R. Dietsch 1), Th. Holz 1), D. Weißbach 1), G. Falkenberg 2), R. Simon 3), U. Fittschen

More information

IMPROVEMENT OF DETECTION LIMITS OF A PORTABLE TXRF BY REDUCING ELECTRICAL NOISE

IMPROVEMENT OF DETECTION LIMITS OF A PORTABLE TXRF BY REDUCING ELECTRICAL NOISE Copyright JCPDS-International Centre for Diffraction Data 2012 ISSN 1097-0002 281 IMPROVEMENT OF DETECTION LIMITS OF A PORTABLE TXRF BY REDUCING ELECTRICAL NOISE Susumu Imashuku 1, Deh Ping Tee 1, Yasukazu

More information

PARAMETERISATION OF FISSION NEUTRON SPECTRA (TRIGA REACTOR) FOR NEUTRON ACTIVATION WITHOUT THE USED OF STANDARD

PARAMETERISATION OF FISSION NEUTRON SPECTRA (TRIGA REACTOR) FOR NEUTRON ACTIVATION WITHOUT THE USED OF STANDARD Parameterisation of Fission Neutron Spectra (TRIGA Reactor) 81 7 PARAMETERISATION OF FISSION NEUTRON SPECTRA (TRIGA REACTOR) FOR NEUTRON ACTIVATION WITHOUT THE USED OF STANDARD Liew Hwi Fen Noorddin Ibrahim

More information

Natural Radiation Map of the Sudan

Natural Radiation Map of the Sudan IOSR Journal of Applied Physics (IOSR-JAP) e-issn: 2278-4861.Volume 9, Issue 4 Ver. III (Jul. Aug. 2017), PP 35-39 www.iosrjournals.org Natural Radiation Map of the Sudan * Magdi Hassan Saad 1, 2 1 - Department

More information

CALCULATION OF THE DETECTOR-CONTRIBUTION TO ZIRCONIUM PEAKS IN EDXRF SPECTRA OBTAINED WITH A SI-DRIFT DETECTOR

CALCULATION OF THE DETECTOR-CONTRIBUTION TO ZIRCONIUM PEAKS IN EDXRF SPECTRA OBTAINED WITH A SI-DRIFT DETECTOR CALCULATION OF THE DETECTOR-CONTRIBUTION TO ZIRCONIUM PEAKS IN EDXRF SPECTRA OBTAINED WITH A SI-DRIFT DETECTOR A. C. Neiva 1, J. N. Dron 1, L. B. Lopes 1 1 Escola Politécnica da Universidade de São Paulo

More information

X-Ray Photoelectron Spectroscopy (XPS) Prof. Paul K. Chu

X-Ray Photoelectron Spectroscopy (XPS) Prof. Paul K. Chu X-Ray Photoelectron Spectroscopy (XPS) Prof. Paul K. Chu X-ray Photoelectron Spectroscopy Introduction Qualitative analysis Quantitative analysis Charging compensation Small area analysis and XPS imaging

More information

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous? Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous? 2. Briefly discuss dead time in a detector. What factors are important

More information

Method development for analysis of single hot particles in Safeguards swipe samples

Method development for analysis of single hot particles in Safeguards swipe samples 1 IAEA-CN-184/177 Method development for analysis of single hot particles in Safeguards swipe samples Zs. Mácsik 1, N. Vajda 2, É. Széles 1, R. Katona 1 1 Institute of Isotopes, Hungarian Academy of Sciences,

More information

Determination of the activity of radionuclides

Determination of the activity of radionuclides BUREAU NATIONAL DE MÉTROLOGIE COMMISSARIAT À L'ÉNERGIE ATOMIQUE LABORATOIRE NATIONAL HENRI BECQUEREL Note technique LNHB/04-33 Determination of the activity of radionuclides contained in volume samples

More information

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy Topic 2b: X-ray Fluorescence Spectrometry Text: Chapter 12 Rouessac (1 week) 4.0 X-ray Fluorescence Download, read and understand EPA method 6010C ICP-OES Winter 2009 Page 1 Atomic X-ray Spectrometry Fundamental

More information

THIN FILM SORBENTS FOR TXRF ANALYSIS

THIN FILM SORBENTS FOR TXRF ANALYSIS Copyright(C)JCPDS-nternational Centre for Diffraction Data 2000, Advances in X-ray Analysis, Vol.42 9 Copyright(C)JCPDS-nternational Centre for Diffraction Data 2000, Advances in X-ray Analysis, Vol.42

More information

HOW TO APPROACH SCANNING ELECTRON MICROSCOPY AND ENERGY DISPERSIVE SPECTROSCOPY ANALYSIS. SCSAM Short Course Amir Avishai

HOW TO APPROACH SCANNING ELECTRON MICROSCOPY AND ENERGY DISPERSIVE SPECTROSCOPY ANALYSIS. SCSAM Short Course Amir Avishai HOW TO APPROACH SCANNING ELECTRON MICROSCOPY AND ENERGY DISPERSIVE SPECTROSCOPY ANALYSIS SCSAM Short Course Amir Avishai RESEARCH QUESTIONS Sea Shell Cast Iron EDS+SE Fe Cr C Objective Ability to ask the

More information

CHEM*3440. X-Ray Energies. Bremsstrahlung Radiation. X-ray Line Spectra. Chemical Instrumentation. X-Ray Spectroscopy. Topic 13

CHEM*3440. X-Ray Energies. Bremsstrahlung Radiation. X-ray Line Spectra. Chemical Instrumentation. X-Ray Spectroscopy. Topic 13 X-Ray Energies very short wavelength radiation 0.1Å to 10 nm (100 Å) CHEM*3440 Chemical Instrumentation Topic 13 X-Ray Spectroscopy Visible - Ultraviolet (UV) - Vacuum UV (VUV) - Extreme UV (XUV) - Soft

More information

An Analysis of Secondary Enhancement Effects in Quantitative XRFA

An Analysis of Secondary Enhancement Effects in Quantitative XRFA An Analysis of Secondary Enhancement Effects in Quantitative XRFA Michael Mantler Institut fur Angewandte und Technische Physik Vienna University of Technology, Vienna, Austria Secondary enhancement effects

More information

REALIZATION OF AN ASYMMETRIC MULTILAYER X-RAY MIRROR

REALIZATION OF AN ASYMMETRIC MULTILAYER X-RAY MIRROR Copyright(c)JCPDS-International Centre for Diffraction Data 2000,Advances in X-ray Analysis,Vol.43 218 REALIZATION OF AN ASYMMETRIC MULTILAYER X-RAY MIRROR S. M. Owens Laboratory for High Energy Astrophysics,

More information

Laser Spectroscopy on Bunched Radioactive Ion Beams

Laser Spectroscopy on Bunched Radioactive Ion Beams Laser Spectroscopy on Bunched Radioactive Ion Beams Jon Billowes University of Manchester Balkan School on Nuclear Physics, Bodrum 2004 Lecture 1. 1.1 Nuclear moments 1.2 Hyperfine interaction in free

More information

High Accuracy EUV Reflectometry and Scattering at the Advanced Light Source

High Accuracy EUV Reflectometry and Scattering at the Advanced Light Source High Accuracy EUV Reflectometry and Scattering at the Advanced Light Source Eric Gullikson Lawrence Berkeley National Laboratory 1 Reflectometry and Scattering Beamline (ALS 6.3.2) Commissioned Fall 1994

More information

Portable type TXRF analyzer: Ourstex 200TX

Portable type TXRF analyzer: Ourstex 200TX Excerpted from Adv. X-Ray. Chem. Anal., Japan: 42, pp. 115-123 (2011) H. Nagai, Y. Nakajima, S. Kunimura, J. Kawai Improvement in Sensitivity and Quantification by Using a Portable Total Reflection X-Ray

More information

FUNDAMENTAL PARAMETER METHOD FOR THE LOW ENERGY REGION INCLUDING CASCADE EFFECT AND PHOTOELECTRON EXCITATION

FUNDAMENTAL PARAMETER METHOD FOR THE LOW ENERGY REGION INCLUDING CASCADE EFFECT AND PHOTOELECTRON EXCITATION Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume 45. 511 FUNDAMENTAL PARAMETER METHOD FOR THE LOW ENERGY REGION INCLUDING CASCADE EFFECT AND PHOTOELECTRON

More information

AP5301/ Name the major parts of an optical microscope and state their functions.

AP5301/ Name the major parts of an optical microscope and state their functions. Review Problems on Optical Microscopy AP5301/8301-2015 1. Name the major parts of an optical microscope and state their functions. 2. Compare the focal lengths of two glass converging lenses, one with

More information

MODERN ATOMIC THEORY AND THE PERIODIC TABLE

MODERN ATOMIC THEORY AND THE PERIODIC TABLE C10 04/19/2013 13:34:14 Page 114 CHAPTER 10 MODERN ATOMIC THEORY AND THE PERIODIC TABLE SOLUTIONS TO REVIEW QUESTIONS 1. Wavelength is defined as the distance between consecutive peaks in a wave. It is

More information

Higher Physics. Particles and Waves

Higher Physics. Particles and Waves Perth Academy Physics Department Higher Physics Particles and Waves Particles and Waves Homework Standard Model 1 Electric Fields and Potential Difference 2 Radioactivity 3 Fusion & Fission 4 The Photoelectric

More information

COMPARATIVE STUDY OF PIGE, PIXE AND NAA ANALYTICAL TECHNIQUES FOR THE DETERMINATION OF MINOR ELEMENTS IN STEELS

COMPARATIVE STUDY OF PIGE, PIXE AND NAA ANALYTICAL TECHNIQUES FOR THE DETERMINATION OF MINOR ELEMENTS IN STEELS COMPARATIVE STUDY OF PIGE, PIXE AND NAA ANALYTICAL TECHNIQUES FOR THE DETERMINATION OF MINOR ELEMENTS IN STEELS ANTOANETA ENE 1, I. V. POPESCU 2, T. BÃDICÃ 3, C. BEªLIU 4 1 Department of Physics, Faculty

More information

Geogenic versus Anthropogenic Metals and Metalloids

Geogenic versus Anthropogenic Metals and Metalloids Geogenic versus Anthropogenic Metals and Metalloids Geochemical methods for evaluating whether metals and metalloids are from geogenic versus anthropogenic sources 1 Definitions Geogenic from natural geological

More information

IMPLEMENTATION OF THE MONTE CARLO-LIBRARY LEAST- SQUARES APPROACH TO ENERGY DISPERSIVE X-RAY FLUORESCENCE ANALYSIS

IMPLEMENTATION OF THE MONTE CARLO-LIBRARY LEAST- SQUARES APPROACH TO ENERGY DISPERSIVE X-RAY FLUORESCENCE ANALYSIS 227 IMPLEMENTATION OF THE MONTE CARLO-LIBRARY LEAST- SQUARES APPROACH TO ENERGY DISPERSIVE X-RAY FLUORESCENCE ANALYSIS Fusheng Li, Weijun Guo, and Robin P. Gardner Center for Engineering Applications of

More information

Particle Analysis of Environmental Swipe Samples

Particle Analysis of Environmental Swipe Samples IAEA-SM-367/10/07 Particle Analysis of Environmental Swipe Samples D. DONOHUE, S. VOGT, A. CIURAPINSKI, F. RUEDENAUER, M. HEDBERG Safeguards Analytical Laboratory International Atomic Energy Agency Vienna,

More information

Copyright(c)JCPDS-International Centre for Diffraction Data 2001,Advances in X-ray Analysis,Vol

Copyright(c)JCPDS-International Centre for Diffraction Data 2001,Advances in X-ray Analysis,Vol Copyright(c)JCPDS-International Centre for Diffraction Data 2001,Advances in X-ray Analysis,Vol.44 386 COMPARISON OF THREE UNIVERSAL CURVES FOR THE ESCAPE PROBABILITY OF X-RAY EXCITED ELECTRONS II. EVALUATION

More information

(a) (i) State the proton number and the nucleon number of X.

(a) (i) State the proton number and the nucleon number of X. PhysicsAndMathsTutor.com 1 1. Nuclei of 218 84Po decay by the emission of an particle to form a stable isotope of an element X. You may assume that no emission accompanies the decay. (a) (i) State the

More information

ION-EXCHANGE FILMS FOR ELEMENT CONCENTRATION IN X-RAY FLUORESCENCE ANALYSIS WITH TOTAL REFLECTION OF THE PRIMARY BEAM.

ION-EXCHANGE FILMS FOR ELEMENT CONCENTRATION IN X-RAY FLUORESCENCE ANALYSIS WITH TOTAL REFLECTION OF THE PRIMARY BEAM. 822 ION-EXCHANGE FILMS FOR ELEMENT CONCENTRATION IN X-RAY FLUORESCENCE ANALYSIS WITH TOTAL REFLECTION OF THE PRIMARY BEAM. Abstract A.P.Morovov, L.D.Danilin, V.V.Zhmailo, Yu.V.Ignatiev, A.E.Lakhtikov,

More information

Calibration of the IXPE Instrument

Calibration of the IXPE Instrument Calibration of the IXPE Instrument Fabio Muleri (INAF-IAPS) On behalf of the IXPE Italian Team 13th IACHEC Meeting 2018 Avigliano Umbro (Italy), 9-12 April 2018 IXPE MISSION IXPE will (re-)open the polarimetric

More information

MCSHAPE: A MONTE CARLO CODE FOR SIMULATION OF POLARIZED PHOTON TRANSPORT

MCSHAPE: A MONTE CARLO CODE FOR SIMULATION OF POLARIZED PHOTON TRANSPORT Copyright JCPDS - International Centre for Diffraction Data 2003, Advances in X-ray Analysis, Volume 46. 363 MCSHAPE: A MONTE CARLO CODE FOR SIMULATION OF POLARIZED PHOTON TRANSPORT J.E. Fernández, V.

More information

RADIOLOGICAL CHARACTERIZATION Laboratory Procedures

RADIOLOGICAL CHARACTERIZATION Laboratory Procedures RADIOLOGICAL CHARACTERIZATION Laboratory Procedures LORNA JEAN H. PALAD Health Physics Research Unit Philippine Nuclear Research Institute Commonwealth Avenue, Quezon city Philippines 3-7 December 2007

More information

Advances in Field-Portable XRF

Advances in Field-Portable XRF Advances in Field-Portable XRF Volker Thomsen and Debbie Schatzlein Field-portable x-ray fluorescence (XRF) allows us to take the laboratory to the sample. The latest generation of such handheld x-ray

More information

Electron Microprobe Analysis 1 Nilanjan Chatterjee, Ph.D. Principal Research Scientist

Electron Microprobe Analysis 1 Nilanjan Chatterjee, Ph.D. Principal Research Scientist 12.141 Electron Microprobe Analysis 1 Nilanjan Chatterjee, Ph.D. Principal Research Scientist Massachusetts Institute of Technology Electron Microprobe Facility Department of Earth, Atmospheric and Planetary

More information

Electron Microprobe Analysis 1 Nilanjan Chatterjee, Ph.D. Principal Research Scientist

Electron Microprobe Analysis 1 Nilanjan Chatterjee, Ph.D. Principal Research Scientist 12.141 Electron Microprobe Analysis 1 Nilanjan Chatterjee, Ph.D. Principal Research Scientist Massachusetts Institute of Technology Electron Microprobe Facility Department of Earth, Atmospheric and Planetary

More information

QUANTITATIVE ENERGY-DISPERSIVE ELECTRON PROBE X-RAY MICROANALYSIS OF INDIVIDUAL PARTICLES

QUANTITATIVE ENERGY-DISPERSIVE ELECTRON PROBE X-RAY MICROANALYSIS OF INDIVIDUAL PARTICLES QUANTITATIVE ENERGY-DISPERSIVE ELECTRON PROBE X-RAY MICROANALYSIS OF INDIVIDUAL PARTICLES 287 Chul-Un Ro Department of Chemistry, Inha University 253, Yonghyun-dong, Nam-gu, Incheon 402-751, Korea ABSTRACT

More information

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer Inductively Coupled Plasma Optical Emission Spectrometer Inductively Coupled Plasma Optical Emission Spectrometer Inductively Coupled Plasma Optical Emission Spectrometer is powerful simultaneous full

More information

Nuclear Physics Questions. 1. What particles make up the nucleus? What is the general term for them? What are those particles composed of?

Nuclear Physics Questions. 1. What particles make up the nucleus? What is the general term for them? What are those particles composed of? Nuclear Physics Questions 1. What particles make up the nucleus? What is the general term for them? What are those particles composed of? 2. What is the definition of the atomic number? What is its symbol?

More information

Experiment 9. Emission Spectra. measure the emission spectrum of a source of light using the digital spectrometer.

Experiment 9. Emission Spectra. measure the emission spectrum of a source of light using the digital spectrometer. Experiment 9 Emission Spectra 9.1 Objectives By the end of this experiment, you will be able to: measure the emission spectrum of a source of light using the digital spectrometer. find the wavelength of

More information

The Periodic Table of the Elements

The Periodic Table of the Elements The Periodic Table of the Elements All matter is composed of elements. All of the elements are composed of atoms. An atom is the smallest part of an element which still retains the properties of that element.

More information

SOURCES of RADIOACTIVITY

SOURCES of RADIOACTIVITY Section 9: SOURCES of RADIOACTIVITY This section briefly describes various sources of radioactive nuclei, both naturally occurring and those produced artificially (man-made) in, for example, reactors or

More information

2. Which of the following statements help(s) to explain why gas can fill the vessel containing it completely while liquid cannot?

2. Which of the following statements help(s) to explain why gas can fill the vessel containing it completely while liquid cannot? Name: Class: ( ) There are 30 questions. Time Allowed: 45 min 1. Kinetic theory explains the behaviour of a substance in terms of the behaviour of the molecules in it. Which of the following is/are the

More information

NJCTL.org 2015 AP Physics 2 Nuclear Physics

NJCTL.org 2015 AP Physics 2 Nuclear Physics AP Physics 2 Questions 1. What particles make up the nucleus? What is the general term for them? What are those particles composed of? 2. What is the definition of the atomic number? What is its symbol?

More information

Data report for elemental analysis of IMPROVE samples collected during April, May, June 2006 UC Davis - Submitted May 14, 2008 SUMMARY

Data report for elemental analysis of IMPROVE samples collected during April, May, June 2006 UC Davis - Submitted May 14, 2008 SUMMARY Data report for elemental analysis of IMPROVE samples collected during April, May, June 2006 UC Davis - Submitted May 4, 2008 SUMMARY This report summarizes the quality assurance performed during elemental

More information

IAEA-TECDOC-9SO. Sampling, storage

IAEA-TECDOC-9SO. Sampling, storage IAEA-TECDOC-9SO Sampling, storage The IAEA does The originating Sections of this publication in the IAEA were: Agency's Laboratories, Seibersdorf Physics Section International Atomic Energy Agency Wagramerstrasse

More information

EDS User School. Principles of Electron Beam Microanalysis

EDS User School. Principles of Electron Beam Microanalysis EDS User School Principles of Electron Beam Microanalysis Outline 1.) Beam-specimen interactions 2.) EDS spectra: Origin of Bremsstrahlung and characteristic peaks 3.) Moseley s law 4.) Characteristic

More information