The performance you demand... the service you deserve... from the company you trust. Updated with:

Size: px
Start display at page:

Download "The performance you demand... the service you deserve... from the company you trust. Updated with:"

Transcription

1 Equity Capillary GC Columns The performance you demand... the service you deserve... from the company you trust. Updated with: NEW Equity-0 columns New Applications sigma-aldrich.com/supelco

2 The performance you demand... the service you deserve... from the company you trust. Choose Equity for consistent, reproducible performance with: Special Purpose GC/MS Analyses Demanding Environmental Methods General Purpose Applications Table of Contents Equity Column Quick Look-Up Guide... The Resolution You Need... The Analyte Response You Require... The Low Bleed You Expect... The Column Life You Count On... 0 Equity Applications Alcohols Blood Alcohol (SPME/GC)... Hydrocarbons and Alcohols (GC)... Fusel Oils in Vodka (GC)... Alditol Acetates (GC)... Amines (GC)... Low Molecular Weight (GC)... Anilines (GC)... BAMEs Bacterial Acid Methyl Esters (GC)... Dioxin and Furans (GC/MS)... Drugs Drug Screen on Equity- (GC/MS)... Drug Screen on Equity-0 (GC/MS)... Foods, Flavors and Fragrances Distilled Lime Oil (GC)... 0 Cold Pressed Lemon Oil (GC)... Fuels Fuel Oils, (GC)... Fuel Oils,, (GC)... Glycols Glycols and Diols (GC)... Haloacetic Acids US EPA Method. Haloacetic Acids (GC)... Herbicides US EPA Method Chlorinated Acids (GC)... Hydrocarbons Simple Hydrocarbons (GC)... Hydrocarbons and Alcohols (GC)... Diesel Fuel (GC)... Unleaded Gasoline (GC)... Ketones Impurities in Methyl Ethyl Ketone (GC)... Odors Trace Odors in Drinking Water (SPME/GC)... PCBs US EPA Method 0 Polychlorinated Biphenyls (GC)... 0 US EPA Method 0 Polychlorinated Biphenyls (Fast GC)... Pesticides US EPA Method 0 Chlorinated Pesticides (GC)... US EPA Method 0 Chlorinated Pesticides (Fast GC)... US EPA Method 0 Chlorinated Pesticides (GC)... US EPA Method Organophosphorus Pesticides (GC)... US EPA Method Organophosphorus Pesticides (GC/MS)... Phenols US EPA Method 0 Phenols (GC)... US EPA Method 0 Methylated Phenols (GC)... Semivolatiles Phthalate Esters (GC)... US EPA Method 0 Semivolatile Compounds (GC/MS), Primary Analyte List... US EPA Method 0 Semivolatile Compounds (GC/MS), Supplemental Appendix IX List... Solvents Industrial Solvents (GC)... 0 Pharmaceutical Solvents, Class (GC)... Pharmaceutical Solvents, Class (GC)... Pharmaceutical Solvents, Class (GC)... Residual Solvents (GC)... Volatiles Indoor Air (GC/MS)... Popular GC Accessories Agilent Technologies Instruments... PerkinElmer Instruments... Varian Instruments... Services and Support... 0 Ordering Information...

3 Supelco s new and improved line of capillary GC columns consistently deliver the resolution you need, the low bleed you expect, and the column life you count on. Supelco s new and improved Equity Capillary GC Columns deliver the capillary GC column performance you demand for your nonpolar applications. Significant improvements in the polymer chemistry are at the heart of the enhanced performance you will receive with our new Equity Capillary GC Columns. The polymer improvements result in better cross-linking, higher thermal stability, and superior product reproducibility. The consistent resolution, analyte response, low bleed, and column life from one Equity column to the next will allow you to reliably transfer methods between sites or instruments within the same site. Also, maintain the expected column performance over time within the same instrument when you need to replace your column. The reproducible performance Equity provides will minimize time consuming method adjustments and troubleshooting with column changes. This equals more tests run with higher confidence. Equity Capillary GC Column Quick Look-Up Guide The following table provides an overview of the current capillary GC columns available in the new Equity line. For more detailed ordering information please refer to page of this brochure. Equity- Equity- Equity-0 Phase bonded; poly(dimethylsiloxane) bonded; poly (% diphenyl/ bonded; poly (% cyanopropylphenyl/ % dimethylsiloxane) % dimethylsiloxane) Temperature Limits 0. and 0.mm ID: 0. and 0.mm ID: 0. and 0.mm ID: -0 C to /0 C -0 C to /0 C subambient to 0 C 0.mm ID: 0.mm ID: 0.mm ID: -0 C to 00/0 C (<=.µm df) -0 C to 00/0 C (<=.µm df) subambient to 0 C -0 C to 0/0 C (>.µm df) -0 C to 0/0 C (>.µm df) Column IDs 0.0, 0., 0., 0.0, 0.0, 0., 0., 0.0, 0., 0., and 0.mm IDs, and 0.mm IDs and 0.mm IDs Column Lengths varies; 0 to 00 meters varies; to 0 meters varies; to 0 meters Column Film Thickness varies; 0.0 to.0µm varies; 0.0 to.0µm varies; 0. to.µm Custom Dimensions yes; please inquire for details on yes; please inquire for details on yes; please inquire for details on custom dimensions custom dimensions custom dimensions

4 The Resolution You Need Equity- Resolution of Aromatics Column: 0m x 0.mm ID, 0.µm Cat. No.: 0-U Oven: 0 C, 0 C/min to 00 C ( min) Inj.: 00 C Det.: FID, 0 C Carrier Gas: Helium, 0 C Injection: µl, 00: split Sample: UST Modified Gasoline Range Organics (Cat. No. ) Excellent baseline separation. Methyl tert-butyl ether. Benzene. Toluene. Ethylbenzene. m/p-xylene. o-xylene.,,-trimethylbenzene.,,-trimethylbenzene. Naphthalene 0 G00 Equity- Resolution of Pesticides Column: 0m x 0.mm ID, 0.µm Cat. No.: 0-U Oven: C ( min), C/min to 00 C ( min) Inj.: C Det.: ECD, 00 C Carrier Gas: Helium, 00 C Injection: µl, splitless Sample: 0pg on-column of a component EPA Method 0 pesticide standard Excellent baseline separation 0. g-chlordane. Endosulfan I. a-chlordane., -DDE. Dieldrin. Endrin. Endosulfan II., -DDD. Endrin aldehyde 0. Endosulfan sulfate., -DDT G000 Equity-0 Resolution of Pesticides Column: 0m x 0.mm ID, 0.µm Cat. No.: -U Oven: 00 C ( min), C/min to 0 C, C/min to 0 C (0 min) Inj.: C Det.: ECD, 0 C Carrier Gas: Helium, C Injection: µl, splitless (0. min) Sample: 0ppb of a component chlorinated pesticide standard (Cat. No. -U) 0 Peak ID s on page.0.0 G000

5 For accurate identification, reliable quantitation, and confidence in your results, choose Equity Capillary GC columns. The consistently high resolution you demand and the service you deserve. Equity- Reproducible Resolution Across Phase Lots and Manufacturing Batches Column: 0m x 0.mm ID, 0.µm Cat. No.: 0-U Oven: 0 C, 0 C/min to 00 C ( min) Inj.: 00 C Det.: FID, 0 C Carrier Gas: Helium, 0 C Injection: µl, 00: split Sample: UST Modified Gasoline Range Organics (Cat. No. ). Ethylbenzene. m/p-xylene. o-xylene.,,-trimethylbenzene.,,-trimethylbenzene Phase Lot Phase Lot Phase Lot G00,, Equity- Reproducible Resolution Across Phase Lots and Manufacturing Batches Column: 0m x 0.mm ID, 0.µm Cat. No.: 0-U Oven: 0 C ( min), 0 C/min to C ( min) Inj.: 0 C MSD Interface: C Scan Range: -0m/z Carrier Gas: Helium, 0 C Injection: µl, splitless Sample: ng on-column of a component semivolatile standard. Benzo(b)fluoranthene. Benzo(k)fluoranthene Phase Lot Phase Lot Phase Lot G0000, 0, 0 Equity-0 Reproducible Resolution Across Phase Lots and Manufacturing Batches.,,,-Tetrachlorom-xylene (surr.). a-bhc. g-bhc. Heptachlor. Aldrin. b-bhc. d-bhc. Heptachlor epoxide. Endosulfan I 0. g-chlordane. a-chlordane., -DDE. Dieldrin. Endrin., -DDD. Endosulfan II., -DDT. Endrin aldehyde. Methoxychlor 0. Endosulfan sulfate. Endrin ketone. Decachlorobiphenyl (surr.) Run conditions same as page. 0 0 Excellent peak shape, resolution and analyte response Phase Lot Phase Lot Phase Lot G00 G00 G000

6 The Analyte Response You Require Equity- Excellent Analyte Response Column: 0m x 0.mm ID, 0.µm Cat. No.: 0-U Oven: 0 C, C/min to 0 C ( min) Inj.: 0 C Det.: FID, 0 C Carrier Gas: Helium, 0 C Injection: µl, 0: split Sample: Grob Test Mix (Cat. No. 0),-Butanediol: Excellent response and peak symmetry 0.,-Butanediol. Decane. Octanol.,-Dimethylphenol. Nonanal. Undecane. -Ethyl hexanoic acid.,-dimethylaniline. Methyl decanoate Methyl undecanoate. Methyl dodecanoate G000 Equity- Excellent Analyte Response Column: 0m x 0.mm ID, 0.µm Cat. No.: 0-U Oven: 0 C ( min), 0 C/min to C ( min) Inj.: 0 C MSD Interface: C Scan Range: -0m/z Carrier Gas: Helium, 0 C Injection: µl, splitless Sample: ng on-column of a component semivolatile standard Excellent response and peak symmetry for pentachlorophenol and benzidine. Pentachlorophenol. Phenanthrene. Anthracene. Benzidine G000 Equity-0 Excellent Analyte Response 0 Column: 0m x 0.mm ID, 0.µm Cat. No.: -U Oven: 00 C ( min), C/min to 0 C, C/min to 0 C (0 min) Inj.: C Det.: ECD, 0 C Carrier Gas: Helium, C Injection: µl, splitless (0. min) Sample: 0ppb of a component chlorinated pesticide standard (Cat. No. -U) Excellent response Peak ID s on page G000

7 For lower detection limits and less instrument downtime, you can depend on Equity Capillary GC columns. The reproducible analyte response you demand and the service you deserve. Equity- Reproducible Analyte Response Across Phase Lots and Manufacturing Batches Column: 0m x 0.mm ID, 0.µm Cat. No.: 0-U Oven: 0 C ( min), C/min to C ( min) Inj.: 0 C Det.: FID, 0 C Carrier Gas: Helium, 0 C Injection:.0µL, 00: split Sample: Nonpolar Column Test Mix (Cat. No. 00-U) % Response: Calculated relative to the predicted hydrocarbon response at the same retention time % Response % % % % % % % % % % % Consistent Response for -Octanol % 0% % % % % % % % % % % 0 Different Phase Lots and Manufacturing Batches G000 Equity- Reproducible Analyte Response Across Phase Lots and Manufacturing Batches % Consistent Response for,-dimethylaniline Column: 0m x 0.mm ID, 0.µm Cat. No.: 0-U Oven: 0 C ( min), C/min to C ( min) Inj.: 0 C Det.: FID, 0 C Carrier Gas: Helium, 0 C Injection: µl, 00: split Sample: Nonpolar Column Test Mix (00-U) %Response: Calculated relative to the predicted hydrocarbon response at the same retention time % Response % % % % % 0% % % 0% 0% % % % Different Phase Lots and Manufacturing Batches G000 Equity-0 Reproducible Analyte Response Across Phase Lots and Manufacturing Batches.,,,-Tetrachloro-m-xylene (surr.). a-bhc. g-bhc. Heptachlor. Aldrin. b-bhc. d-bhc. Heptachlor epoxide. Endosulfan I 0. g-chlordane. a-chlordane., -DDE. Dieldrin. Endrin., -DDD. Endosulfan II., -DDT. Endrin aldehyde 0 0 Excellent peak shape, resolution and analyte response Phase Lot Phase Lot Phase Lot. Methoxychlor 0. Endosulfan sulfate. Endrin ketone. Decachlorobiphenyl (surr.) G00 G00 G000

8 The Low Bleed You Expect Equity- Reproducible Low Column Bleed Across Phase Lots and Manufacturing Batches Column: 0m x 0.mm ID, 0.µm Cat. No.: 0-U Oven: 0 C ( min), C/min to C ( min) Inj.: 0 C Det.: FID, 0 C Carrier Gas: Helium, 0 C Injection: µl, 00: split Sample: Nonpolar Column Test Mix (Cat. No. 00-U) pa pa pa Phase Lot Phase Lot Phase Lot FID C G000, 0, 0 Equity- Reproducible Low Column Bleed Across Phase Lots and Manufacturing Batches Column: 0m x 0.mm ID, 0.µm Cat. No.: 0-U Oven: 0 C ( min), C/min to C ( min) Inj.: 0 C Det.: FID, 0 C Carrier Gas: Helium, 0 C Injection: µl, 00: split Sample: Nonpolar Column Test Mix (Cat. No. 00-U) pa pa pa Phase Lot Phase Lot Phase Lot FID C G00,, Equity-0 Reproducible Low Column Bleed Across Phase Lots and Manufacturing Batches Column: 0m x 0.mm ID, 0.µm Cat. No.: -U Oven: C (0 min), C/min to 0 C ( min) Inj.: 0 C Det.: FID, 0 C Carrier Gas: Helium, C Injection: µl, 00: split Sample: Modified intermediate polarity test mix.0pa Phase Lot.pA Phase Lot.pA Phase Lot FID Bleed at 0 C G00 G00 G00

9 For great sensitivity, reliable identification, and increased sample throughput, rely on Equity Capillary GC columns. The consistent low bleed performance you demand and the service you deserve. Equity- Low GC/MS Column Bleed Column: 0m x 0.mm ID, 0.µm Cat. No.: 0-U Oven: 0 C ( min), 0 C/min to 00 C ( min), C/min to C ( min) Inj.: 0 C MSD Interface: C Scan Range: -0m/z Carrier Gas: Helium, 0 C Injection: µl, pulsed splitless (pulsed to 0psi for 0. min) Sample: ng on-column of a component EPA Method 0 standard Superb GC/MS signal-to-noise ratio at nanograms Clean Mass Spectrum (unsubtracted for background) nanograms Benzo(g,h,i)perylene (m/z ) 0 0 G00 Equity Low GC/MS Column Bleed Column: 0m x 0.mm ID, 0.µm Cat. No.: 0-U Oven: 0 C ( min), 0 C/min to 00 C ( min), C/min to C ( min) Inj.: 0 C MSD Interface: C Scan Range: -0m/z Carrier Gas: Helium, 0 C Injection: µl, pulsed splitless (pulsed to 0psi for 0. min) Sample: ng on-column of a component EPA Method 0 semivolatile standard Superb GC/MS signal-to-noise ratio at nanograms Clean Mass Spectrum (unsubtracted for background) nanograms Benzo(g,h,i)- perylene (m/z ) 0 G00 Equity-0 Low ECD Column Bleed Column: 0m x 0.mm ID, 0.µm Cat. No.: -U Oven: 0 C, C/min to 0 C ( min) Inj.: 0 C Det.: ECD, 0 C Carrier Gas: Helium, 0 C Injection: µl, splitless (0. min) Liner: mm ID double taper Sample: Custom mix in MTBE diluted and derivatized with diazomethane. Dalapon.,-Dichlorobenzoate. -Nitrophenol. Dicamba. Dichloroprop.,-D. Pentachlorophenol.,,-TP. Chloramben 0.,,-T. Dinoseb.,-DB. Bentazon. Picloram. Dacthal. Acifluorfen G00, 0 Low ECD Bleed

10 The Column Life You Count On Equity- Durability Challenge Column: 0m x 0.mm ID, 0.µm Cat. No.: 0-U Oven: C ( min), 0 C/min to C ( min) Inj.: 0 C Det.: FID, 0 C Carrier Gas: Helium, C Injection: µl, 00: split Sample: Test Mix. to ng on-column of a component semivolatile standard; the column challenge mix is a high concentration waste sample. Response factor is calculated relative to the internal standard, -Difluorobiphenyl Relative Response Factor Final response after clipping one loop off the column. Benzidine Very consistent response throughout the durability challenge test Pentachlorophenol Durability Test The column durability and life were challenged for over 0 injections by alternating injections of the µl test mix followed by consecutive Number of Injections µl splitless injections of the high concentration waste sample. Column maintenance was performed at the end of the test before a final test mix was injected. G000 0 Equity- Durability Challenge Column: 0m x 0.mm ID, 0.µm Cat. No.: 0-U Oven: C ( min), 0 C/min to C ( min) Inj.: 0 C Det.: FID, 0 C Carrier Gas: Helium, C Injection: µl, 00: split Sample: Test Mix. to ng on-column of a component semivolatile standard; the column challenge mix is a high concentration waste sample. Response factor is calculated relative to the internal standard, -Difluorobiphenyl Durability Test Relative Response Factor Response recovered well after clipping one loop from the column Pentachlorophenol Benzoic acid The column durability and life were challenged for over 0 injections by alternating injections of the µl test mix followed by consecutive µl splitless injections of the high concentration waste sample. Number of Injections Column maintenance was performed at the end of the test before a final test mix was injected. G00 Equity-0 Durability Challenge Column: 0m x 0.mm ID, 0.µm Cat. No.: -U Oven: C ( min), C/min to 0 C Inj.: 0 C Det.: FID, 0 C Carrier Gas: Helium, C Injection: µl, 00: split Sample: Test Mix-% each solvent by weight in methanol Durability Test The column durability and life were challenged by repeatedly ramping the GC oven up to 0 C and holding for four hours. After each four-hour increment, a solvent standard was analyzed. This sequence was repeated until the column had experienced a total of hours at 0 C. First injection after hours Last injection after hours Isopropyl acetate.,-dichloroethane. Isobutanol. -Methoxyethanol. Trichloroethene. -Ethoxyethyl acetate. -Butoxyethanol G00 Consistent performance throughout the challenge G00

11 To increase your productivity and reduce your instrument downtime, use Equity Capillary GC columns. The durable, consistent column life you demand and the service you deserve. Equity- Durable Analyte Response Column: 0m x 0.mm ID, 0.µm Cat. No.: 0-U Oven: C ( min), 0 C/min to C ( min) Inj.: 0 C Det.: FID, 0 C Carrier Gas: Helium, C Injection: µl, 00: split Sample: Test Mix. to ng on-column of a component semivolatile standard; the column challenge mix is a high concentration waste sample. Response factor is calculated relative to the internal standard, -Difluorobiphenyl Durability Test The column durability and life were challenged for over 0 injections by alternating injections of the µl test mix followed by consecutive µl splitless injections of the high concentration waste sample. Column maintenance was performed at the end of the test before a final test mix was injected.. Pentachlorophenol. Phenanthrene. Anthracene Last injection after column maintenance 0th Injection First Injection G00,, Equity- Durable Analyte Response Column: 0m x 0.mm ID, 0.µm Cat. No.: 0-U Oven: C ( min), 0 C/min to C ( min) Inj.: 0 C Det.: FID, 0 C Carrier Gas: Helium, C Injection: µl, 00: split Sample: Test Mix. to ng on-column of a component semivolatile standard; the column challenge mix is a high concentration waste sample.. Pentachlorophenol. Phenanthrene. Anthracene Last injection after column maintenance Response factor is calculated relative to the internal standard, -Difluorobiphenyl 0th Injection Durability Test The column durability and life were challenged for over 0 injections by alternating injections of the µl test mix followed by consecutive µl splitless injections of the high concentration waste sample. Column maintenance was performed at the end of the test before a final test mix was injected. First Injection G00,, Equity-0 Durable Analyte Response Column: 0m x 0.mm ID, 0.µm Cat. No.: -U Oven: 00 C ( min), C/min to 0 C, C/min to 0 C (0 min) Inj.: C Det.: ECD, 0 C Carrier Gas: Helium, C Injection: µl, splitless (0. min) Sample: 0ppb of a component chlorinated pesticide standard (Cat. No. -U).,,,-Tetrachlorom-xylene (surr.). a-bhc. g-bhc. Heptachlor. Aldrin. b-bhc. d-bhc. Heptachlor epoxide. Endosulfan I 0. g-chlordane. a-chlordane., -DDE. Dieldrin. Endrin., -DDD. Endosulfan II., -DDT. Endrin aldehyde. Methoxychlor 0. Endosulfan sulfate. Endrin ketone. Decachlorobiphenyl (surr.) 0 0 Excellent peak shape, resolution and analyte response Phase Lot Phase Lot Phase Lot G00 G00 G000

12 Alcohols - Blood Alcohol (SPME/GC) Column: Equity-, 0m x 0.mm ID,.0µm Cat. No.: 0-U Oven: C (. min), 0 C/min to 0 C ( min) Sample: Blood alcohols in ml serum in ml vial, all analytes at 0.% or 00mg/dL SPME Fiber: Carbowax-DVB Stableflex Cat. No.: -U Extraction: Heated headspace, 0 C, min Desorption: minutes at 0 C Inj.: 0 C Det.: FID, 0 C Carrier Gas: Helium, C Injection: SPME fiber, split 0: Liner: 0.mm SPME liner. Acetaldehyde. Methanol. Ethanol. Acetone. Isopropanol. n-propanol (internal standard) Excellent Peak Symmetry for Alcohols 0 G00 Alcohols - Hydrocarbons and Alcohols (GC) Column: Equity-, 0m x 0.mm ID,.0µm Cat. No.: 0-U Oven: 0 C ( min), C/min to C (0 min) Inj.: 0 C Det.: FID, C Carrier Gas: Helium, 0 C Injection: 0.0µL, split 00: Liner: Split, cup design Sample: component mixed solvent sample, equal by weight. Methanol. Ethanol. Isopropanol. t-butanol. Propanol. -Butanol. Hexane. Isobutanol U. Unknown. Butanol 0. -Methyl--butanol. -Pentanol. -Pentanol. Heptane. -Methyl--butanol. -Methyl--butanol. -Methyl--pentanol. -Methyl--pentanol. Pentanol. Octane 0. -Methyl--pentanol. Hexanol. Nonane. Heptanol. Decane. Octanol. Undecane. Dodecane. Decanol. Tridecane 0. Tetradecane. Pentadecane. Hexadecane Excellent Peak Shapes and Resolutions 0, 0 0 U G000

13 Alcohols - Fusel Oils in Vodka (GC) Column: Equity-0, 0m x 0.mm ID,.0µm Cat. No.: -U Oven: 0 C ( min), C/min to C ( min) Inj.: 0 C Det.: FID, 0 C Carrier Gas: Helium, 0 C Injection: µl, split 00: Liner: mm ID single tapered Sample: 000ppm in % undenatured ethanol. Acetaldehyde. Methanol. n-propanol. Ethyl acetate. Isobutanol. Isoamyl alcohol All compounds resolved from solvent peak G0000

14 Alditol Acetates (GC) Column: Equity-0, 0m x 0.mm ID, 0.µm Cat. No.: -U Oven: 0 C isothermal Inj: 0 C Det.: FID, 0 C Carrier Gas: Helium, 0 C Injection: µl, : split Liner: split cup design Sample: Alditol acetate 00ppm in methylene chloride (Cat. Nos. 0-U & ). Rhamnitol. Fucitol. Ribitol. Arabinitol. Inositol. Mannitol. Glucitol. Galactitol Key Resolution Achieved G0000

15 Amines (GC) Column: Equity-, 0m x 0.mm ID,.0µm Cat. No.: 0-U Oven: C ( min), C/min to C Inj.: 0 C Det.: FID, 00 C Carrier Gas: Helium, C Injection: µl, split 00: Liner: mm ID, straight Sample: 00ppm each amine in methanol Excellent Response and Peak Shape. Propionitrile. Diethylamine. Diisopropylamine. -Methyl-pyrrolidine. Triethylamine. Pyridine. Acrylamide. Benzonitrile. Benzylamine 0. Octylamine. Nonylamine. Decylamine. Unknown impurity. Toluenediamine. Dicyclohexylamine G000 Amines - Low Molecular Weight (GC) Column: Equity-, 0m x 0.mm ID,.0µm Cat. No.: 0-U Oven: C ( min), 0 C/min to C Inj.: 0 C Det.: FID, 00 C Carrier Gas: Helium, C Injection: µl, split 00: Liner: mm ID, straight Sample: 00ppm each amine in methanol Solvent. Methylamine. Dimethylamine. Ethylamine. Trimethylamine Complete Amine Separation at C Initial Temperature.0.0 G000

16 Anilines (GC) Column: Equity-, 0m x 0.mm ID, 0.µm Cat. No.: 0-U Oven: 0 C ( min), 0 C/min to 00 C, C/min to C ( min) Inj.: 0 C Det.: FID, C Carrier Gas: Helium,.mL/min, constant Injection:.0µL, splitless (0. min) Liner: Splitless, mm ID single taper Sample: 0ng on-column of a custom anilines mix. Aniline. -Aminobenzotrifluoride. o-toluidine. N,N-Dimethylaniline. -Chloroaniline.,-Dimethylaniline. -Chloro--fluoroaniline. -Isopropylaniline. -Methyl--ethylaniline 0. -Chloro--methylaniline.,-Diethylaniline.,-Diaminotoluene.,-Dichloroaniline.,,-Trichloroaniline. -Chloro--nitroaniline.,'-Dichlorobenzidine Excellent Peak Shapes and Resolutions 0 Low FID Bleed C 0 0 G000

17 BAMEs - Bacterial Acid Methyl Esters (GC) Column: Equity-, 0m x 0.mm ID, 0.µm Cat. No.: 0-U Oven: 0 C ( min), C/min to 0 C ( min) Inj.: 0 C Det.: FID, 0 C Carrier Gas: Helium, 0 C Injection:.0µL, split 00: Liner: Split, cup design Sample: 00ng on-column of a component BAME standard (Cat. No. 00-U) Solvent. Me. Undecanoate (C:0). Me. -Hydroxydecanoate (-OH-C0:0). Me. Dodecanoate (C:0). Me. Tridecanoate (C:0). Me. -Hydroxydodecanoate (-OH-C:0). Me. -Hydroxydodecanoate (-OH-C:0). Me. Tetradecanoate (C:0). Me. -Methyltetradecanoate (i-c:0). Me. -Methyltetradecanoate (a-c:0) 0. Me. Pentadecanoate (C:0). Me. -Hydroxytetradecanoate (-OH-C:0). Me. -Hydroxytetradecanoate (-OH-C:0). Me. -Methylpentadecanoate (i-c:0). Me. cis--hexadecenoate (C: ). Me. Hexadecanoate (C:0). Me. -Methylhexadecanoate (i-c:0). Me. cis-,0-methylenehexadecanoate (C:0D). Me. Heptadecanoate (C:0D). Me. -Hydroxyhexadecanoate (-OH-C:0) 0. Me. cis, -Octadecadienoate (C:, ). Me. cis--octadecanoate (C: Cis). Me. trans--octadecanoate (C: trans). Me. Octadecanoate (C:0). Me. cis-,0-methyleneoctadecanoate (C:0D). Me. Nonadecanoate (C:0). Me. Eicosanoate (C0:0) Excellent Peak Shape and Response Solvent 0 0 G Dioxin and Furans (GC/MS) Separation of all Target Analytes Column: Equity-, 0m x 0.mm ID x 0.µm Cat. No.: 00-U Oven: 0 C ( min), C/min to C ( min) Inj.: 0 C MSD Interface: C Scan Range: SIM Carrier Gas: Helium, cm/sec, constant Injection: µl, splitless ( min) Liner: mm ID, single taper Sample: Dioxin standard, 00-00ppb in octane,, % Resolution Between Peaks and. C-,,,-TCDF.,,,-TCDF. C-,,,-TCDD. C-,,,-TCDD.,,,-TCDD.,,,,-PCDF.,,,,-PCDF.,,,,-PCDD, 0,,.,,,,,-HxCDF 0.,,,,,-HxCDF.,,,,,-HxCDF.,,,,,-HxCDD. C-,,,,,-HxCDD.,,,,,-HxCDD. C-,,,,,-HxCDD.,,,,,-HxCDD.,,,,,-HxCDF. C-,,,,,,-HpCDF.,,,,,,-HpCDF 0.,,,,,,-HpCDD.,,,,,,-HpCDF. C-OCDD. OCDD. OCDF 0, 0 G0000

18 Drugs - Drug Screen (GC/MS) Column: Equity-, 0m x 0.mm ID, 0.µm Cat. No.: 0-U Oven: C ( min), C/min to 0 C, C/min to 00 C, C/min to 0 C ( min) Inj.: 0 C MSD Interface: C Scan Range: 0-0m/z Carrier Gas: Helium, C Injection: 0.µL pulsed splitless (pulsed to 0psi until 0. min) split open at 0. min Liner: mm ID, straight Sample: ~ng on-column of a component drug standard. Amphetamine. Methamphetamine. Nicotine. Caffeine. Diphenhydramine. Lidocaine. Phenobarbital. Methadone. Amitriptyline 0. Cocaine. Desipramine. Codeine. Morphine. Diazepam. Heroin. Fentenyl Amphetamine: Excellent Response and Peak Symmetry 0 Key Resolutions Achieved 0 0 G00

19 Drugs - Drug Screen (GC/MS) Column: Equity-0, 0m x 0.mm ID, 0.µm Cat. No.: -U Oven: C ( min), C/min to 0 C, C/min to 00 C, C/min to 0 C ( min) Inj.: 0 C MSD Interface: 0 C Scan Range: 0-0m/z Carrier Gas: Helium, 0.mL/min constant flow Injection: 0.µL pulsed splitless (pulsed to 0psi for 0. min) split open at 0. min Liner: mm ID straight Sample: 0ppm drug standard in methanol. Amphetamine. Methamphetamine. Nicotine. Diphenhydramine. Caffeine. Lidocaine. Methadone. Phenobarbital. Amitriptyline 0. Cocaine. Desipramine. Codiene. Diazepam. Heroin. Fentenyl Key Resolutions Achieved 0 Low MS Bleed G0000

20 Foods, Flavors and Fragrances - Distilled Lime Oil (GC) Column: Equity-, 0m x 0.mm ID, 0.µm Cat. No.: 0-U Column: Equity-, 0m x 0.mm ID, 0.µm Cat. No.: 0-U Oven: C ( min), C/min to 00 C (0 min) Inj.: 0 C Det.: FID, 0 C Carrier Gas: Helium, 0 C Injection: Wet needle, split 00: Liner: Split, cup design Sample: Distilled lime oil. a-pinene. Camphene. b-pinene. Myrcene. a-phellandrene.,-cineole. a-terpinene. p-cymene. d-limonene 0. g-terpinene. Terpinolene. Linalool. a-fenchyl alcohol. Terpinen--ol. b-terpineol. Borneol. Terpinen--ol. a-terpineol. g-terpineol 0. Decanal. Neral. Geranial. Neral acetate. Geranyl acetate. Dodecanal. b-caryophyllene. trans-a-bergamotene. trans-a-farnesen. b-bisabolene Equity- 0 Excellent Peak Shapes and Resolution G0000 Equity- 0 Excellent Peak Shapes and Resolution G000

21 Foods, Flavors and Fragrances - Cold Pressed Lemon Oil (GC) Column: Equity-, 0m x 0.mm ID, 0.µm Cat. No.: 0-U Column: Equity-, 0m x 0.mm ID, 0.µm Cat. No.: 0-U Oven: C ( min), C/min to 00 C (0 min) Inj.: 0 C Det.: FID, 0 C Carrier Gas: Helium, 0 C Injection: Wet needle, split 00: Liner: Split, cup design Sample: Cold pressed lemon oil. Heptanal. a-thujene. a-pinene. Camphene. Sabinene. b-pinene. -Methy--heptene--one. Myrcene. Octanal 0. a-phellandrene. -Carene. a-terpinene. p-cymene. d-limonene. g-terpinene. Octanol. Terpinolene. Linalool. Nonanal 0. Citronellal. Terpinen--ol. a-terpineol. Decanal. Octyl acetate. Nerol. Neral. Carvone. Geraniol. Geranial 0. Nonyl acetate. Citronellyl acetate. Neryl acetate. Geranyl acetate. Dodecanal. b-caryophyllene. trans-a-bergamotene. a-humelene. b-bisabolene Equity- Excellent Peak Shapes and Resolution Equity- Excellent Peak Shapes and Resolution G000, G

22 Fuels - Fuel Oils, (GC) Column: Equity-, 0m x 0.mm ID, 0.µm Cat. No.: 0-U Oven: 0 C ( min), C /min to C (0 min) Inj.: C Det.: FID, C Carrier Gas: Helium, 0cm/sec, constant Injection:.0µL, split 00: Liner: mm ID single taper Fuel Oil No. Sample: 00ng on-column of Fuel Oil No. (Cat. No. -U) Excellent Peak Shapes and Response Low FID Bleed G00 Fuel Oil No. Sample: 00ng on-column of Fuel Oil No. (Cat. No. -U) Low FID Bleed G00

23 Fuels - Fuel Oils,, (GC) Column: Equity-, 0m x 0.mm ID, 0.µm Cat. No.: 0-U Oven: 0 C ( min), C /min to C (0 min) Inj.: C Det.: FID, C Carrier Gas: Helium, 0cm/sec, constant Injection:.0µL, split 00: Liner: mm ID single taper Excellent Peak Shapes and Response Fuel Oil No. Sample: 00ng on-column of Fuel Oil No. (Cat. No. -U) Low FID Bleed G00 Fuel Oil No. Sample: 00ng on-column of Fuel Oil No. (Cat. No. -U) Low FID Bleed G00 Fuel Oil No. Sample: 00ng on-column of Fuel Oil No. (Cat. No. -U) Low FID Bleed G00

24 Glycols - Glycols and Diols (GC) Column: Equity-, 0m x 0.mm ID,.µm Cat. No.: 0-U Oven: 0 C ( min), C/min to 00 C ( min) Inj.: 0 C Det.: FID, 00 C Carrier gas: Helium, cm/sec, constant Injection: µl, pulsed splitless, (pulsed to 0psi until 0.0 min) split open at 0. min Liner: mm ID, straight Sample: 00ppm glycol standard in methanol. -Methoxyethanol (Methyl cellosolve). Ethylene glycol. -Ethoxyethanol (Cellosolve). Propylene glycol.,-butanediol.,-propanediol. -Butoxyethanol (Butyl cellosolve).,-butanediol. -(-Ethoxyethoxy) ethanol (Carbitol) 0. Dipropylene glycol. -(-Butoxyethoxy) ethanol (Butyl carbitol) Excellent Peak Shape Low ppm for ethylene(eg) and propylene glycol(pg) G00 Haloacetic Acids - US EPA Method. Haloacetic Acids (GC) Column: Equity-0, 0m x 0.mm ID, 0.mm Cat. No.: -U Oven: 0 C (0 min), C/min to C ( min), 0 C/min to 0 C ( min) Inj.: 00 C Det.: ECD, 0 C Carrier gas: Helium, C Injection: µl, splitless (0. min) Liner: mm ID single taper Sample: component mix, 0-00ppb in MTBE (Cat. Nos.: -, 0-U, -U, -U) Key resolution achieved. Monochloroacetic acid (MCAA). Monobromoacetic acid (MBAA). Dalapon. Dichloroacetic acid (DCAA). Trichloroacetic acid (TCAA).,,-Trichloropropane (internal standard). Bromochloroacetic acid (BCAA). Bromodichloroacetic acid (BDCAA). Dibromoacetic acid (DBAA) 0. Chlorodibromoacetic acid (CDBAA).,-Dibromopropionic acid (surrogate). Tribromoacetic acid (TBAA) (all compounds except internal standard were methylated) G0000

25 Herbicides - US EPA Method Chlorinated Acids (GC) Column: Equity-, 0m x 0.mm ID, 0.µm Cat. No.: 0-U Column: Equity-0, 0m x 0.mm ID, 0.µm Cat. No.: -U Oven: 0 C, C/min to 00 C Inj.: 0 C Det.: ECD, 0 C Carrier gas: Helium, 0 C Injection: µl, splitless (0. min) Liner: mm ID double taper Sample: Custom mix in MTBE diluted and derivatized with diazomethane Equity-. Dalapon.,-Dichlorobenzoate. -Nitrophenol. Dicamba. Dichloroprop.,-D. Pentachlorophenol.,,-TP. Chloramben 0.,,-T. Dinoseb.,-DB. Bentazon. Picloram. Dacthal. Acifluorfen, Excellent Peak Shapes and Resolution 0 Stable Baseline No Bleed G000 Equity-0 program ends at 0 C, G00

26 Hydrocarbons - Simple Hydrocarbons (GC) Column: Equity-, 0m x 0.mm ID, 0.µm Cat. No.: 0-U Column: Equity-, 0m x 0.mm ID, 0.µm Cat. No.: 0-U Oven: 0 C ( min), C/min to C ( min) Inj.: Track oven Det.: FID, C Carrier gas: Helium,.mL/min, constant Injection: 0.0µL, cold on column Liner: Not applicable Sample: 00ng on-column of a component n-hydrocarbon standard (Cat. No. -U). C. C0. C. C. C. C. C0. C. C 0. C. C. C0. C. C. C. C. C0 Equity- Equity Excellent Peak Shape and Response 0 Low FID Bleed G000 Low FID Bleed G000 Hydrocarbons - Hydrocarbons and Alcohols (GC) Column: Equity-, 0m x 0.mm ID,.0µm Cat. No.: 0-U Oven: 0 C ( min), C/min to C ( min) Inj.: 0 C Det.: FID, C Carrier gas: Helium, 0 C Injection: 0.0µL, split 00: Liner: Split, cup design Sample: component mixed solvent sample, equal by weight Excellent Peak Shapes. Methanol. Ethanol. Isopropanol. t-butanol. Propanol. -Butanol. Hexane. Isobutanol U. Unknown. Butanol 0. -Methyl--butanol. -Pentanol. -Pentanol. Heptane. -Methyl--butanol. -Methyl--butanol. -Methyl--pentanol. -Methyl--pentanol. Pentanol. Octane 0. -Methyl--pentanol. Hexanol. Nonane. Heptanol. Decane. Octanol. Undecane. Dodecane. Decanol. Tridecane 0. Tetradecane. Pentadecane. Hexadecane 0, 0 0 U G000

27 Hydrocarbons - Diesel Fuel (GC) Column: Equity-, 0m x 0.mm ID, 0.µm Cat. No.: 0-U Oven: 0 C ( min), C/min to C ( min) Inj.: C Det.: FID, C Carrier gas: Helium, 0cm/sec, constant Injection:.0µL, split 00: Liner: mm ID single taper Sample: 00ng on-column of a No. Fuel Oil standard (Cat. No. -U) Excellent Peak Shapes and Response Low FID Bleed C G00 Hydrocarbons - Unleaded Gasoline (GC) Column: Equity-, 0m x 0.mm ID, 0.µm Cat. No.: 0-U Oven: 0 C (0 min), C/min to 00 C Inj.: 0 C Det.: FID, 0 C Carrier gas: Helium, 0 C Injection: µl, 00: split Liner: Split, cup design Sample: Unleaded gasoline, neat. Methyl-t-butyl ether. Benzene. Toluene. Octane. Ethylbenzene. m/p-xylenes. o-xylene.,,-trimethylbenzene.,,-trimethylbenzene 0. Decane. Naphthalene. Dodecane G00

28 Ketones - Impurities in Methyl Ethyl Ketone (GC) Column: Equity-0, 0m x 0.mm ID,.µm Cat. No.: -U Oven: C (0 min), C/min to 00 C Inj.: 0 C Det.: FID, 0 C Carrier gas: Helium, C Injection: µl, 0: split Liner: mm ID cup style Sample: Methyl ethyl ketone of various purity levels ACS Reagent Grade 0. Methanol. Ethanol. Acetone. Isopropanol. t-butanol. n-propanol. n-butanol. Ethyl acetate. Diethoxymethane 0. sec-butanol. Methyl isobutyl ketone. Isopropyl acetate. Isobutanol. Toluene. -Methyl--pentanone. -Octene 0 0 G00000 Commercial Grade G0000 Laboratory Standard G0000

29 Odors - Trace Odors in Drinking Water (SPME/GC) Column: Equity-, 0m x 0.mm ID, 0.µm Cat. No.: 0-U Sample: ml of water containing % NaCl and drinking water odors kit, Cat. No. -U SPME Fiber: cm StableFlex coated with 0/0µm DVB/Carboxen/PDMS Cat. No.: -U Extraction: headspace, C (0 min) Desorption: min at 0 C Oven: 0 C ( min), C/min to 00 C Liner: 0.mm SPME liner MSD Interface: 0 C Scan Range: Selected m/z (SIM),,,, Carrier gas: Helium, ml/min, constant Injection: SPME fiber, splitless, opened after 0mL/min. -Isopropyl--methoxypyrazine, ppt. -Isobutyl--methoxypyrazine, ppt. -Methylisoborneol, ppt.,,-trichloroanisole (Internal Standard), ppt. (±)Geosmin, ppt Excellent Analyte Response at ppt G00

30 PCBs - US EPA Method 0 Polychlorinated Biphenyls (GC) Column: Equity-, 0m x 0.mm ID, 0.µm Cat. No.: 0-U Column: Equity-0, 0m x 0.mm ID, 0.µm Cat. No.: -U Oven: 00 C ( min), C/min to 0 C, C/min to 00 C (0 min) Inj.: C Det.: ECD, 0 C Carrier gas: Helium, 00 C Injection:.0µL, splitless (0. min) Liner: mm ID double taper Sample: ppb of Aroclors 0 & 0 with surrogates at.ppb (Cat. No. -U).,,,-Tetrachloro-m-xylene (surr.),.ppb. Aroclor 0, ppb. Aroclor 0, ppb. Decachlorobiphenyl (surr.),.ppb Equity- Excellent Peak Shape and Resolution Stable Baseline, Low Bleed G000 Equity-0 program ends at 0 C Excellent Peak Shape and Resolution Stable Baseline, Low Bleed G0000

31 PCBs - US EPA Method 0 Polychlorinated Biphenyls (Fast GC) Column: Equity-, m x 0.0mm ID, 0.0µm Cat. No.: 0-U Oven: 00 C, 0 C/min to 00 C, C/min to 0 C ( min) Inj.: C Det.: ECD, 0 C Carrier gas: Hydrogen, 0cm/sec, constant Injection: µl, splitless (0. min) Liner: mm ID single taper Sample: 00ppb of Aroclors 0 & 0 with surrogates at 0ppb (Cat. No. -U).,,,-Tetrachloro-m-xylene (surr.), 0ppb. Aroclor 0, 00ppb. Aroclor 0, 00ppb. Decachlorobiphenyl (surr.), 0ppb G00

32 Pesticides - US EPA Method 0 Chlorinated Pesticides (GC) Column: Equity-, 0m x 0.mm ID, 0.µm Cat. No.: 0-U Oven: 0 C, C/min to 00 C Inj.: 0 C Det.: ECD, 0 C Carrier gas: Helium, 0 C Injection: µl, splitless (0. min) Liner: mm ID double taper Sample: Custom mix in MTBE, each component at 0.µg/mL Excellent Peak Shapes and Resolution 0. Etridiazole. Chlorneb. Propachlor. Trifuluralin. a-bhc. Hexachlorobenzene. b-bhc. g-bhc. d-bhc 0. Chlorothalonil. Heptachlor. Aldrin. Dacthal. Heptachlor epoxide. g-chlordane. Endosulfan I. a-chlordane., -DDE/Dieldrin. Endrin 0. Endosulfan II. Chlorobenzilate., -DDD. Endrin aldehyde. Endosulfan sulfate., -DDT. Methoxychlor. cis/trans-permethrin G00 Pesticides - US EPA Method 0 Chlorinated Pesticides (Fast GC) Column: Equity-, m x 0.0mm ID, 0.0µm Cat. No.: 0-U Oven: 00 C, 0 C/min to 00 C, C/min to 0 C ( min) Inj.: C Det.: ECD, 0 C Carrier Gas: Hydrogen, 0cm/sec, constant Injection: µl, splitless (0. min) Liner: mm ID single taper Sample: 0ppb of a component chlorinated pesticide standard (Cat. No. -U).,,,-Tetrachloro-m-xylene (surr.). a-bhc. b-bhc. g-bhc. d-bhc. Heptachlor. Aldrin. Heptachlor epoxide. g-chlordane 0. Endosulfan I. a-chlordane., -DDE. Dieldrin. Endrin. Endosulfan II., -DDD. Endrin aldehyde. Endosulfan sulfate., -DDT 0. Endrin ketone. Methoxychlor. Decachlorobiphenyl (surr.) 0, G00

33 Pesticides - US EPA Method 0 Chlorinated Pesticides (GC) Column: Equity-, 0m x 0.mm ID, 0.µm Cat. No.: 0-U Column: Equity-0, 0m x 0.mm ID, 0.µm Cat. No.: -U Column: SPB-0, 0m x 0.mm ID, 0.µm Cat. No.: 0-U Oven: 00 C ( min), C/min to 0 C, C/min to 00 C (0 min) Inj.: C Det.: ECD, 0 C Carrier gas: Helium, 00 C Injection:.0µL, splitless (0. min) Liner: mm ID double taper Sample: 0ppb of a component chlorinated pesticide standard (Cat. No. -U).,,,-Tetrachloro-m-xylene (surr.). a-bhc. b-bhc. g-bhc. d-bhc. Heptachlor. Aldrin. Heptachlor epoxide. g-chlordane 0. Endosulfan I. a-chlordane., -DDE. Dieldrin. Endrin. Endosulfan II., -DDD. Endrin aldehyde. Endosulfan sulfate., -DDT 0. Endrin ketone. Methoxychlor. Decachlorobiphenyl (surr.) Equity- Excellent Peak Shape and Resolution G00 Equity-0 program ends at 0 C 0, G00 SPB G00

34 Pesticides - US EPA Method Organophosphorus Pesticides (GC) Column: Equity-, 0m x 0.mm ID, 0.µm Cat. No.: 0-U Oven: 0 C ( min), C/min to 00 C Inj.: 0 C Det.: NPD, 0 C Carrier gas: Helium, 0 C Injection:.0uL, splitless (0. min) Liner: mm ID double taper Sample: 0ng on-column of a custom organophosphorus pesticides mix,. Dichlorvos. Mevinphos. Trichlorfon. TEPP. Thionazin. Demeton O. Ethoprop. Naled. Dicrotophos 0. Monocrotophos. Sulfotepp. Carbophenothion 0, Excellent Peak Shapes and Resolutions, 0. Phorate. Demeton S. Dimethoate. Terbufos. Fonophos. Diazinon. Disulfoton 0. Dichlorofenthion. Phosphamidon. Chlorpyrifos methyl. Methyl parathion. Ronnel 0. Fenitrothion. Malathion. Aspon. Chlorpyrifos. Fenthion 0. Trichloronate. Chlorfenvinphos. Crotoxyphos. Storophos. Tokuthion. Merphos. Fensulfothion. Ethion. Bolstar. Famphur 0. Carbophenothion. Phosmet. EPN. Azinphos-methyl. Leptophos. Azinphos-ethyl. Coumaphos, G000 Column: Equity-0, 0m x 0.mm ID, 0.µm Cat. No.: -U Oven: 0 C ( min), C/min to 0 C ( min) Inj.: 0 C Det.: NPD, 00 C Carrier gas: Helium, 0 C Injection: µl, splitless (0. min) Liner: mm double taper Sample: Custom mix diluted to 0ppm (hexane/acetone :),,,0,. Dichlorvos. Mevinphos. Trichlorfon. Demeton O. Thionazin. Ethoprop. TEPP. Naled. Phorate 0. Sulfotepp. Demeton S. Terbufos,,, 0,,0, 0. Diazinon. Fonophos. Dicrotophos. Disulfoton. Dichlorofenthion. Monocrotophos. Chlorpyrifos methyl 0. Dimethoate. Phosphamidon isomer. Ronnel. Merphos. Aspon. Chloropyrifos. Methyl parathion. Trichloronate. Phosphamidon isomer. Malathion 0. Fenitrothion. Fenthion. Ethyl Parathion. Chlorfenvinphos. Tokuthion. Crotoxyphos. Stirophos. Ethion. Bolstar. Carbophenothion 0. Fensulfothion. Famphur. Leptophos. EPN. Phosmet. Azinphos-methyl. Azinphos-ethyl. Coumaphos G0000

35 Pesticides - US EPA Method Organophosphorus Pesticides (GC/MS) Column: Equity-, 0m x 0.mm ID, 0.µm Cat. No.: 0-U Oven: 0 C ( min), C/min to 0 C ( min) Inj.: 0 C MSD Interface: C Scan Range: -0m/z Carrier gas: Helium, 0 C Injection:.0µL, splitless (0. min) Liner: mm ID double taper Sample: 0ng on-column of a custom organophosphorus pesticides mix. Dichlorvos. Mevinphos. Trichlorfon. TEPP. Thionazin. Demeton O. Ethoprop. Naled. Dicrotophos 0. Monocrotophos. Sulfotepp. Carbophenothion. Phorate. Demeton S. Dimethoate. Terbufos. Fonophos. Diazinon. Disulfoton 0. Dichlorofenthion. Phosphamidon. Chlorpyrifos methyl. Methyl parathion. Ronnel. Fenitrothion. Malathion. Aspon. Chlorpyrifos. Fenthion 0. Trichloronate. Chlorfenvinphos. Crotoxyphos. Stirophos. Tokuthion. Merphos. Fensulfothion. Ethion. Bolstar. Famphur 0. Carbophenothion. Phosmet. EPN. Azinphos-methyl. Leptophos. Azinphos-ethyl. Coumaphos Excellent Peak Shapes and Resolution, 0,0,, 0, 0 Excellent Peak Shapes and Resolution G000

36 Phenols - US EPA Method 0 Phenols (GC) Column: Equity-, 0m x 0.mm ID, 0.µm. Phenol Cat. No.: 0-U. -Chlorophenol Oven: 0 C, C/min to 00 C. -Methylphenol Inj.: C. -Methylphenol Det.: FID, 0 C. -Methylphenol Carrier gas: Helium, 0 C. -Nitrophenol Injection:.0µL, 00: split.,-dimethylphenol Liner: Split, cup design.,-dichlorophenol Sample: Phenols Mix, 0µg/mL each component (Cat. No. ),.,-Dichlorophenol 0. -Chloro--methylphenol.,,-Trichlorophenol.,,-Trichlorophenol.,,-Trichlorophenol.,,-Trichlorophenol.,,-Trichlorophenol.,-Dinitrophenol. -Nitrophenol.,,,-Tetrachlorophenol.,,,-Tetrachlorophenol 0.,,,-Tetrachlorophenol. -Methyl-,-dinitrophenol.,,-Trichlorophenol. Pentachlorophenol. Dinoseb 0 0, Excellent Peak Shape G00 Phenols - US EPA Method 0 Methylated Phenols (GC) Column: Equity-, 0m x 0.mm ID, 0.µm Cat. No.: 0-U Oven: 0 C (. min), C/min to 00 C Inj.: 0 C Det.: ECD, 0 C Carrier gas: Helium, 0 C Injection:.0µL, splitless (0. sec) Liner: mm ID double taper, splitless (0. sec) Sample: µg/ml Phenols Mix (00µL of a 0µg/mL mix/00µl Diazomethane).,-Dichlorophenol. -Chloro--methylphenol.,-Dichlorophenol.,,-Trichlorophenol. -Nitrophenol.,,-Trichlorophenol. -Nitrophenol.,,-Trichlorophenol.,,-Trichlorophenol, 0.,,-Trichlorophenol.,,-Trichlorophenol.,,,-Tetrachlorophenol.,,,-Tetrachlorophenol.,,,-Tetrachlorophenol.,-Dinitrophenol. Pentachlorophenol. -Methyl-,-dinitrophenol. Dinoseb Excellent Peak Shape 0, G000

37 Semivolatiles - Phthalate Esters (GC) Column: Equity-, 0m x 0.mm ID, 0.µm Cat. No.: 0-U Column: Equity-0, 0m x 0.mm ID, 0.µm Cat. No.: -U Oven: 0 C ( min), 0 C/min to C ( min) Inj.: 0 C Det.: FID, C Carrier gas: Helium,.mL/min, constant Injection:.0µL, splitless (0. min) Liner: mm ID single taper Sample: 0ng on-column of a custom phthalate ester mix. Dimethyl phthalate. Diethyl phthalate. Benzyl benzoate. Diisobutyl phthalate. Dibutyl phthalate. Bis(-Methoxyethyl)phthalate. Bis(-Methyl--pentyl)phthalate isomer. Bis(-Ethoxyethyl)phthalate. Diamyl phthalate 0. Di-n-hexyl phthalate. Butyl benzyl phthalate. Hexyl--ethylhexyl phthalate. Bis(-Butoxyethyl)phthalate. Dicyclohexyl phthalate. Bis(-Ethylhexyl)phthalate. Di-n-octyl phthalate. Di-n-nonyl phthalate Equity- Excellent Peak Shapes and Resolution 0 Excellent Peak Shape Low FID Bleed C 0 0 G000 Excellent Peak Shapes and Resolution Equity-0 program ends at 0 C 0 Low FID Bleed 0 C 0 0 G0000

38 Semivolatiles - US EPA Method 0 Semivolatile Compounds (GC/MS), Primary Analyte List Column: Equity-, 0m x 0.mm ID, 0.µm Cat. No.: 0-U Oven: 0 C ( min), 0 C/min to 00 C, 0 C/min to 00 C, 0 C/min to C (. min) Inj.: 0 C MSD Interface: C Scan Range: -0m/z Carrier gas: Helium, pressure programmed, 0psi (0.0 min), ramp to 0psi (0.0 min), ramp to.psi ( min), ramp to psi (hold for remainder of run) Injection:.0µL, splitless (0. min) Liner: mm ID single taper Sample: 0ng on-column of a component semivolatile standard, internal standards, and surrogates. Pyridine. N-Nitrosodimethylamine. -Fluorophenol (Surr.). Phenol-d (Surr.). Phenol. Aniline. Bis(-Chloroethyl)ether. -Chlorophenol-d (Surr.). -Chlorophenol 0.,-Dichlorobenzene.,-Dichlorobenzene-d (Int. Std.).,-Dichlorobenzene. Benzyl alcohol.,-dichlorobenzene-d (Surr.).,-Dichlorobenzene. -Methylphenol. Bis(-Chloroisopropyl)ether. -Methylphenol. N-Nitroso-di-n-propylamine 0. Hexachloroethane. Nitrobenzene-d (Surr.). Nitrobenzene. Isophorone. -Nitrophenol.,-Dimethylphenol. Benzoic acid. Bis(-Chloroethoxy)methane.,-Dichlorophenol.,,-Trichlorobenzene 0. Naphthalene-d (Int. Std.). Naphthalene. -Chloroaniline. Hexachlorobutadiene. -Chloro--methylphenol. -Methylnaphthalene. Hexachlorocyclopentadiene.,,-Trichlorophenol.,,-Trichlorophenol. -Fluorobiphenyl (Surr.) 0. -Chloronaphthalene. -Nitroaniline. Dimethyl phthalate. Acenaphthylene.,-Dinitrotoluene. -Nitroaniline. Acenaphthene-d0 (Int. Std.). Acenaphthene.,-Dinitrophenol. -Nitrophenol 0. Dibenzofuran.,-Dinitrotoluene. Diethyl phthalate. Fluorene. -Chlorophenyl phenyl ether. -Nitroaniline. -Methyl-,-dinitrophenol. N-Nitrosodiphenylamine. Azobenzene.,,-Tribromophenol (Surr.) 0. -Bromophenyl phenyl ether. Hexachlorobenzene. Pentachlorophenol. Phenanthrene-d0 (Int. Std.). Phenanthrene. Anthracene. Carbazole. Di-n-butyl phthalate. Fluoranthene. Benzidine 0. Pyrene. Aramite#. Terphenyl-d (Surr.). Aramite#.,'-Dimethylbenzidine. Butylbenzyl phthalate.,'-dichlorobenzidine. Bis(-Ethylhexyl) phthalate. Benzo(a)anthracene. Chrysene-d (Int. Std.) 0. Chrysene. Di-n-octyl phthalate. Benzo(b)fluoranthene. Benzo(k)fluoranthene. Benzo(a)pyrene. Perylene-d (Int. Std.). Indeno(,,-cd)pyrene. Dibenz(a,h)anthracene. Benzo(g,h,i)perylene, Excellent Peak Shapes and Resolution 0 0, 0 0, Great Phenol Response 0 0 Great Pentachlorophenol Response 0 0 Excellent Peak Shapes and Resolution 0 Low MS Bleed 0 G00

39 Semivolatiles - US EPA Method 0 Semivolatile Compounds (GC/MS), Supplemental Appendix IX List Column: Equity-, 0m x 0.mm ID, 0.µm Cat. No.: 0-U Oven: 0 C ( min), 0 C/min to 00 C, 0 C/min to 00 C, 0 C/min to C (. min) Inj.: 0 C MSD Interface: C Scan Range: -0m/z Carrier gas: Helium, pressure programmed, 0psi (0.0 min), ramp to 0psi (0.0 min), ramp to.psi ( min), ramp to psi (hold for remainder of run) Injection:.0µL, splitless (0. min) Liner: mm ID single taper Sample: 0ng on-column of a component semivolatile standard, internal standards, and surrogates.,-dioxane. Pyridine. -Picoline. N-Nitroso-methylethylamine. Methyl methanesulfonate. -Fluorophenol (surr). N-Nitrosodiethylamine. Ethyl methanesulfonate. Phenol-d (surr) 0. Aniline. Pentachloroethane. -Chlorophenol-d (surr).,-dichlorobenzene-d (internal std.). Benzyl alcohol.,-dichlorobenzene-d (surr). -Methylphenol. N-Nitrosopyrrolidine. Acetophenone. N-Nitrosomorpholine 0. o-toluidine. Nitrobenzene-d (surr). N-Nitrosopiperidine. o,o,o-triethylphosphorothioate. a,a-dimethylphenethylamine. Naphthalene-d (internal std.).,-dichlorophenol. Hexachloropropene-. Phenylenediamine. N-Nitrosodibutylamine 0. Safrole. -Methylnaphthalene.,,,-Tetrachlorobenzene. Isosafrole. -Fluorobiphenyl (surr). Isosafrole-.,-Naphthoquinone.,-Dinitrobenzene.,-Dinitrobenzene 0 0. Acenaphthene-d0 0. Pentachlorobenzene. -Naphthylamine.,,,-Tetrachlorophenol. -Naphthylamine.,,,-Tetrachlorophenol. -Nitro-o-toluidine. Thionazin. Diphenylamine.,,-Tribromophenol (surr). Sulfotep 0.,,-Trinitrobenzene. Diallate-. Phorate. Phenacetin. Diallate-. Dimethoate. -Aminobiphenyl. Pronamide Excellent Peak Shapes and Resolution 0,. Pentachloronitrobenzene. Phenanthrene-d0 (internal std.) 0. Disulfoton. Dinoseb. Methyl parathion. -Nitroquinoline--oxide. Parathion. Methapyrilene. Isodrin. p-terphenyl-d (surr). -Dimethylaminoazobenzene. Chlorobenzilate 0. Famphur. Kepone. -Acetylaminofluorene. Chrysene-d (internal std.).,-dimethylbenz(a)anthracene. Perylene-d (internal std.). -Methylcholanthrene. Dibenzo(a,j)acridine 0,, Low MS Bleed G00

40 Solvents - Industrial Solvents (GC) Column: Equity-, 0m x 0.mm ID,.0µm Cat. No.: 0-U Column: WAX 0, 0m x 0.mm ID,.0µm Cat. No.: Column: Equity-0, 0m x 0.mm ID,.0µm Cat. No.: -U Oven: C ( min), C/min to 0 C ( min) Inj.: 0 C Det.: FID, 0 C Carrier gas: Helium, C Injection: 0.µL, split 00: Liner: Split, cup design Sample: 0.µL of a component neat solvent mixture Equity- 0, Excellent Peak Shapes and Response,,,0, 0,. Methanol. Methyl formate. Ethanol. Acetone. -Propanol. Ethyl formate.,-dichloroethylene. Methylene chloride. Methyl acetate 0. -Propanol. trans-,-dichloroethylene.,-dichloroethane. -Butanone. sec-butanol. Hexane. Ethyl acetate. Chloroform. Tetrahydrofuran. Isobutanol 0. -Methoxyethanol,0.,-Dichloroethane.,,-Trichloroethane. Isopropyl acetate. n-butanol. Benzene. Carbon tetrachloride. -Nitropropane. Trichloroethylene.,-Dioxane 0. -Ethoxyethanol (cellosolve). n-propyl acetate. -Methyl--pentanone. Isoamyl alcohol. Dimethylformamide. Toluene. Isobutyl acetate. -Hexanone. Mesityl oxide. Tetrachloroethene 0. n-butyl acetate, 0. Diacetone alcohol. Chlorobenzene. -Methyl--hexanone. Ethyl benzene. m-xylene. p-xylene. Isoamyl acetate. Cyclohexanol. Styrene 0. o-xylene.,,,-tetrachloroethane. -Ethoxyethyl acetate. Butyl cellosolve. n-amyl acetate. -Methylcyclohexanol.,-Dichlorobenzene. -Methylphenol. -Methylphenol. -Methylphenol, G00 WAX 0,,, 0,,,,,, 0,0,, G00,, Equity-0,,,,, 0 0 0, 0 0,

41 Solvents - Pharmaceutical Solvents, Class (GC) Oven: C ( min), C/min to 00 C Inj.: C Det.: FID, 0 C Carrier gas: Helium, 0cm/sec, constant Injection: µl, split : Liner: mm ID single taper Sample: Class I: ppm in DMSO (Cat. No. ) Class I Concentration Retention Time Identification (µg/ml) Equity- WAX 0 OVI-G.,-Dichloroethylene ,,-Trichloroethane ,-Dichloroethane Carbon tetrachloride Benzene Class Solvents on Equity- Column: 0m x 0.mm ID,.0µm w/m intermediate polarity guard Cat. No.: -U, Class Solvents on WAX 0 Column: 0m x 0.mm ID,.0µm Cat. No.: 0-U G00, Class Solvents on OVI-G G00 Column: 0m x 0.mm ID x.0µm w/m intermediate polarity guard Cat. No.: G00

42 Solvents - Pharmaceutical Solvents, Class (GC) Oven: C ( min), C/min to 00 C Inj.: C Det.: FID, 0 C Carrier gas: Helium, 0cm/sec, constant Class II Concentration Retention Time Identification (µg/ml) Equity- WAX 0 OVI-G. Methanol Acetonitrile Methylene chloride Nitromethane 0.. NI. Hexane cis-,-dichloroethylene Chloroform Methoxyethanol 0....,-Dimethoxyethane Cyclohexane Ethylene glycol Formamide Trichloroethylene ,-Dioxane NI = not integrated Class Solvents on Equity- Column: 0m x 0.mm ID,.0µm w/m intermediate polarity guard Cat. No.: -U Injection: µl, split : Liner: mm ID single taper Sample: Class II: (Cat. No. ) + n-methylpyrrolidone, 0-000ppm in DMSO Class II Concentration Retention Time Identification (µg/ml) Equity- WAX 0 OVI-G. -Ethoxyethanol Methylcyclohexane Pyridine Toluene Dimethylformamide Methyl butyl ketone Chlorobenzene Dimethylacetamide *. m-xylene...0. p-xylene...0. o-xylene.... n-methylpyrrolidone Tetralin Sulfolane *coelutes w/solvent, 0 0, Class Solvents on WAX 0 G00 Column: 0m x 0.mm ID,.0µm Cat. No.: 0-U 0, 0, G00 Class Solvents on OVI-G Column: 0m x 0.mm ID,.0µm w/m intermediate polarity guard Cat. No.: 0, 0, G00

43 Solvents - Pharmaceutical Solvents, Class (GC) Oven: C ( min), C/min to 00 C Inj.: C Det.: FID, 0 C Carrier gas: Helium, 0cm/sec, constant Class III Concentration Retention Time Identification (µg/ml) Equity- WAX 0 OVI-G. Ethanol Acetone Propanol Pentane Ethyl ether Ethyl formate Methyl acetate Propanol Methyl-t-butyl ether Acetic acid 000 NI.0.. -Butanone sec-butanol Ethyl acetate Tetrahydrofuran NI = not integrated Class Solvents on Equity- Column: 0m x 0.mm ID,.0µm w/m intermediate polarity guard Cat. No.: -U Injection: µl, split : Liner: mm ID single taper Sample: Class III: custom mix, approx. 000ppm in MeOH Class III Concentration Retention Time Identification (µg/ml) Equity- WAX 0 OVI-G. Iso-Butanol n-butanol Isopropyl acetate Heptane Propyl acetate Isoamyl alcohol Methyl--pentanone n-amyl alcohol Isobutyl acetate Butyl acetate Dimethyl sulfoxide Anisole Cumene , 0,, Class Solvents on WAX 0 Column: 0m x 0.mm ID,.0µm Cat. No.: 0-U G00,, Class Solvents on OVI-G Column: 0m x 0.mm ID,.0µm w/m intermediate polarity guard Cat. No.:, 0 0 G G00

44 Solvents - Residual Solvents (GC) Column: Equity-, 0m x 0.mm ID,.0µm Cat. No.: -U Oven: 0 C ( min), C/min to 00 C Inj.: C Det.: FID, 0 C Carrier gas: Helium, 0 C Injection:.0µL, split 0: Liner: Split, cup design Sample: ng on-column of a component solvent standard in DMSO. Methanol. Ethanol. Acetonitrile. Acetone. -Propanol. Ethyl ether.,-dichloroethylene. Freon. Methylene chloride 0. Methyl-t-butyl ether. -Butanone. Hexane. Ethyl acetate. Chloroform. Tetrahydrofuran.,,-Trichloroethane.,-Dichloroethane. Carbon tetrachloride. Benzene 0. Trichloroethylene.,-Dioxane. -Methyl--pentanone. Toluene. Dimethylformamide Excellent Peak Shapes and Response, 0, 0 G

45 Volatiles - Indoor Air (GC/MS) Column: Equity-, 0m x 0.mm ID,.0µm Cat. No.: 0-U Oven: C ( min), C/min to 00 C, 0 C/min to 0 C (0 min) Inj.: 0 C MSD Interface: 0 C Scan Range: -0 m/z Carrier gas: Helium, C Injection:.0µL, 0: split Liner: Split, cup design Sample: 0ng on-column of the Japanese Indoor Air Standards Mix (Cat. No. -U) 0. Ethanol. Acetone. -Propanol. Methylene chloride. -Propanol. -Butanone. Hexane. Ethyl acetate. Chloroform 0.,-Dichloroethane.,-Dimethylpentane.,,-Trichloroethane. Benzene. -Butanol. Carbon tetrachloride.,-dichloropropane. Bromodichloromethane. Isooctane. Trichloroethene 0. Heptane. -Methyl--pentanone. Toluene. Chlorodibromomethane. n-butyl acetate,,,, 0, G000 Column: Equity-, 0m x 0.mm ID,.0µm Cat. No.: 00-U Oven: C, ( min), C/min to 00 C, C/min to 0 C (0 min) Inj.: 0 C MSD Interface: 00 C Scan Range: -0 m/z Carrier gas: Helium, cm/sec, constant Injection:.0µL, 0: split Liner: Dual tapered Sample: 00ng on-column of the Japanese Indoor Air Standards Mix (Cat. No. -U). Ethanol. Acetone. -Propanol. Methylene chloride. -Propanol. -Butanone. Hexane. Ethyl acetate. Chloroform 0.,-Dichloroethane.,-Dimethyl pentane.,,-trichloroethane. -Butanol. Benzene. Carbon tetrachloride.,-dichloropropane. Bromodichloroethane. Iso-octane. Trichloroethene 0. Heptane. -Methyl--pentanone. Toluene. Chlorodibromomethane. n-butyl acetate. Octane. Tetrachloroethylene. Ethyl benzene. m/p-xylenes (partially resolved). Octane. Tetrachloroethylene. Ethylbenzene. m/p-xylene. Styrene 0. o-xylene. Nonane. a-pinene. -Ethylbenzene. -Ethylbenzene.,,-Trimethylbenzene. -Ethyltoluene. b-pinene.,,-trimethylbenzene. Styrene 0. o-xylene. Nonane. a-pinene. -Ethylbenzene. -Ethylbenzene.,,-Trimethylbenzene. -Ethyl toluene. b-pinene.,,-trimethylbenzene. Decane 0.,-Dichlorobenzene.,,-Trimethylbenzene. Limonene. Decane 0.,-Dichlorobenzene.,,-Trimethylbenzene. Limonene. Nonanal. Undecane.,,,-Tetramethylbenzene. Decanal. Dodecane. Tridecane. Tetradecane 0. Pentadecane. Hexadecane,, 0, Nonanal. Undecane.,,,-Tetramethylbenzene. Decanal. Dodecane. Tridecane. Tetradecane 0. Pentadecane. Hexadecane Excellent Peak Shapes and Resolution G00

46 GC Accessories Agilent Technologies Instruments Supeltex Capillary Column Ferrules (Short) Use with original Agilent/HP nut or Supelco 0-U replacement nut (P/N -U). We offer the short style ferrules for Agilent/ HP GC's. This design will fit the standard Agilent/ HP capillary nut. They are offered in M-A (% polyamide/% graphite), M- (00% graphite), and CapSeal (graphite/aluminum) versions. Ferrule Type Temp. Limit Qty. Cat. No mm column ID x 0.mm ferrule ID M-A 00 C 0 0-U 0 0-U M- 0 C 0 -U 0 -U CapSeal Bullet 0 C mm column ID x 0.mm ferrule ID M-A 00 C 0 0-U 0 0-U M- 0 C 0 0-U 0 -U CapSeal Bullet 0 C mm column ID x 0.mm ferrule ID M-A 00 C 0 0-U 0 0-U M- 0 C 0 0-U 0 -U CapSeal Bullet 0 C 0 0 Column Nuts for Agilent/HP Use with short Supeltex ferrules (see above). -U These column nuts are replacements for damaged or misplaced original Agilent/HP nuts. They are to be used with the shorter design ferrules for Agilent/HP GC's. Description Cat. No. Column Nuts (pk. of ) -U Accessory Case for Agilent/HP GC Capillary Products We offer a clear plastic storage case with a foam insert. The foam easily stores your capillary accessories. The foam has been cut out to hold your Pk/ inlet liners, Pk/0 septa, Pk/0 ferrules, Pk/ Therm-O-Rings, Column nuts, and Pk/0 Inlet Seals. Description Cat. No. GC Accessory Case for Agilent Technologies 0-U Supeltex Capillary Column Ferrules (General Purpose) 0 Use with Supelco Ferrule Nut Adapter (P/N 0-U or 0). These are the original Supeltex ferrules. Use these ferrules if you have replaced the original Agilent/HP nut with Supelco's Ferrule Nut Adapter. They are offered in M- (ceramic-filled Teflon), M-A (% polyamide/ % graphite), M-B (% polyamide/% graphite), M- (00% graphite), and CapSeal (graphite/aluminum) versions. Ferrule Type Temp. Limit Qty. Cat. No mm column ID x 0.mm ferrule ID M-A 00 C M-A -hole 00 C M-A Indented Blank 00 C 0 M-B 0 C 0 0-U M- 0 C U CapSeal Bullet 0 C 0-U 0.mm column ID x 0.mm ferrule ID M-A 00 C 0 M-A -hole 00 C M-A Indented Blank 00 C 0 M-B 0 C 0 M- 0 C 0 0 CapSeal Bullet 0 C 0.mm column ID x 0.mm ferrule ID M- 0 C 0 M-A 00 C 0 0 M-A Indented Blank 00 C 0 M-B 0 C 0 M- 0 C CapSeal Bullet 0 C 0.mm column ID x.0mm ferrule ID M-A Indented Blank 00 C 0 M- 0 C mm column id x.mm ferrule id M-A 00 C 0 M-A Indented Blank 00 C 0 M- 0 C 0 0 Drill to fit your column. Supelco Ferrule Nut Adapters 0-U Use with general purpose Supeltex ferrules (see above). P0000 Install fused silica capillary columns without restrictions on ferrule choice. These adapters enable you to use general purpose Supeltex and other /" compression capillary ferrules in your Agilent/HP 0, 0, 0, 0, 0, or 0 system. Description Cat. No. Adapters (pk. of ) 0-U Adapters, Knurled (pk. of ) 0 P000

47 Supeltex Capillary Ferrules (Long) Use with original Agilent/HP MSD Source Nut, SSNE Style Nut (P/N 0-U), or Supelco MSD Source Nut(P/N ). We offer a preconditioned ferrule for Agilent/ HP GC/MS applications in M-A material (% polyamide/% graphite). -U Description Qty. Cat. No mm column ID 0 -U x 0.mm ferrule ID 0 0-U 0.mm column ID 0 -U x 0.mm ferrule ID 0 0-U 0.mm column ID 0 -U x 0.mm ferrule ID 0 0-U Column Nut for Agilent/HP MSD Use with long Supeltex ferrules. These column nuts are replacements for damaged or misplaced original Agilent/HP MSD nuts. They are to be used with the longer design ferrules for Agilent/HP GC's. Description Qty. Cat. No. SSNE style columns nut 0-U MSD Source Nut for GC/MS Interface Use with long or generalpurpose Supeltex ferrules. These column nuts can be used to replace damaged or misplaced original Agilent/HP source nuts. The nuts are made of brass to prevent damage to MSD source P000 threads. An enlarged knurled end allows easy finger tightening for a leak tight seal. Description Cat. No. MSD Source Nut Thermogreen LB- Septa P000 P000 Inlet Seals -U The inlet seal on an Agilent/HP GC must be regularly changed to prevent sample adsorption due to accumulation of sample residue and/or septum fragments. We manufacture replacment seals of high quality stainless steel for analyses of non-reactive compounds, and stainless steel seals plated with pure gold for applications requiring more inertness. No brighteners are used in the plating process. Stainless steel washers are included with each type of seal. Description Cat. No. Stainless Steel Inlet Seals (pk. of ) -U Stainless Steel Inlet Seals (pk. of 0) -U Stainless Steel Inlet Seals, 00 Seals w/0 washers -U Gold Plated Inlet Seals (pk. of ) -U Gold Plated Inlet Seals (pk. of 0) -U Therm-O-Ring Seals for Capillary Inlet Liners 00-U Exclusive from Supelco. New high temperature O-ring seals can be used with inlet temperatures up to C without sticking or fragmenting. Fit both.mm OD (split) and.mm OD (splitless) Agilent/HP capillary liners, and any /" OD capillary liner that uses an O-ring seal. Superior replacement for Viton O-rings. Description Cat. No. Therm-O-Ring Seals (pk. of 0) 00-U Therm-O-Ring Seals (pk. of ) 00-U Deactivated Glass Inlet Liners Our liners feature: High temperature silanization, to ensure inertness Consistent dimensions, tolerances and quality In-house manufacturing that meets or exceeds instrument manufacturer s specifications All Models, 0, 0, 0, 0. (pk/). P000 P000 Lowest bleed of any septum we have tested. Extremely low bleed over a wide range of inlet temperatures 00 C to 0 C Already conditioned, ready to use Easier needle penetration and high puncture tolerance ideal for autosamplers Rubber formulation exclusive to Supelco 0 (Pk. of 0). P0000 Description Cat. No. Split Injection. x.mm, mm ID, wool packed 00. x.mm, cup design 000. x.mm, cup design, wool packed 00 Splitless. x.mm, tapered 00. x.mm, tapered, wool packed 00. x.mm, mm ID 00. x.mm, dual tapered 00 Direct/Wire-Bore. x.mm,.mm ID 00. x.mm, 0.mm ID, SPME 0 Description Diameter Cat. No. 0A, 0 mm (/ ) 0 00 Series, 0.mm (/ ) 0 0/0, 0, OCI Ports mm (/ ) 0

48 GC Accessories PerkinElmer Instruments Supeltex Capillary Column Ferrules -U Use with original PerkinElmer / or SSNE Style Nuts (p/n 0-U). P000 Supeltex Capillary Column Ferrules (General Purpose) Use with / compression nuts. P000 0 Ferrule Type Temp. Limit Qty. Cat. No. Ferrule Type Temp. Limit Qty. Cat. No mm column ID x 0.mm ferrule ID M-A 00 C 0 -U 0 0-U M- 0 C 0 0-U 0 0-U CapSeal Bullet 0 C 0.mm column ID x 0.mm ferrule ID M-A 00 C 0 -U 0 0-U M- 0 C 0 0-U 0 0-U CapSeal Bullet 0 C -U 0.mm column ID x 0.mm ferrule ID M-A 00 C 0 -U 0 0-U M- 0 C 0 0-U 0 0-U CapSeal Bullet 0 C mm column ID x.0mm ferrule ID CapSeal Bullet 0 C -U SSNE Style Column Nut Description Qty. Cat. No. SSNE Style Column Nut 0-U Therm-O-Ring Seals Exclusive from Supelco. New high temperature O-ring seals can be used with inlet temperatures up to C without sticking or fragmenting. They fit / capillary liners. Description Qty. Cat. No. Therm-O-Ring Seals 00-U Thermogreen LB- Septa Lowest bleed of any septum we have tested. Extremely low bleed over a wide range of inlet temperatures 00 C to 0 C Already conditioned, ready to use Easier needle penetration and high puncture tolerance ideal for autosamplers Rubber formulation exclusive to Supelco Sigma series, 00 & 0, 000 Auto Sampler Description Qty. Cat. No..0mm mm column ID x 0.mm ferrule ID M-A 00 C M- 0 C U 0.mm column ID x 0.mm ferrule ID M-A 00 C 0 M- 0 C mm column ID x 0.mm ferrule ID M-A 00 C 0 0 M- 0 C Swagelok / Compression Nut These nuts permit use of general purpose Supeltex and other / compression capillary ferrules. Description Qty. Cat. No. Swagelok / brass nut 0 0 Inlet Liners (Pk/). Our liners feature: High temperature silanization, to ensure inertness In-house manufacturing that meets or exceeds instrument manufacturer s specifications Description Cat. No. Auto System 000 Split/Splitless Capillary Injector Split Injection mm x 0.,mm ID 00 mm x 0., mm ID 00 Splitless mm x 0., mm ID 0 mm x 0., 0.mm ID, SPME 0 PPS (Programmed Split/Splitless) Split Injection mm x mm, mm ID 0 Splitless mm x mm, mm ID 0 Direct/On-Column/Other mm x mm, On-Column 0 Accessory Cases for PerkinElmer GC Capillary Products We offer a clear plastic storage case with a foam insert. The foam easily stores your capillary accessories. The foam has been cut out to hold your Pk/ inlet liners, Pk/0 septa, Pk/0 ferrules, Pk/ Therm-O-Rings, and Column nuts. Description Cat. No. GC Accessory Case for PerkinElmer 0-U

49 GC Accessories Varian Instruments Supeltex Capillary Column Ferrules Use with Varian Nut (p/n 0-U). -U Ferrule Type Temp. Limit Qty. Cat. No mm column ID x 0.mm ferrule ID M-A 00 C 0 -U 0 0-U M- 0 C 0 0-U 0 0-U CapSeal Bullet 0 C 0.mm column ID x 0.mm ferrule ID M-A 00 C 0 -U 0 0-U M- 0 C 0 0-U 0 0-U CapSeal Bullet 0 C -U 0.mm column ID x 0.mm ferrule ID M-A 00 C 0 -U 0 0-U M- 0 C 0 0-U 0 0-U CapSeal Bullet 0 C mm column ID x.0mm ferrule ID CapSeal Bullet 0 C -U Column Nuts Description Cat. No. Column Nut for Varian GC (pk. of ) 0-U Thermogreen LB- Septa Lowest bleed of any septum we have tested. Extremely low bleed over a wide range of inlet temperatures 00 C to 0 C Already conditioned, ready to use Description Diameter Cat. No. Injectors mm 0-U Packed column injectors.mm 0 SPI mm 0 Capillary Injectors mm 0.mm Saturn GC/MS.mm P000 Deactivated Glass Inlet Liners (Pk/). Our liners feature: High temperature silanization, to ensure inertness Consistent dimensions, tolerances and quality In-house manufacturing that meets or exceeds instrument manufacturer s specifications Description Cat. No. Model CP Injector Split Injection. x.mm, mm ID, wool packed 00. x.mm, cup design 000. x.mm, cup design, wool packed 00. x.mm, cup design, 0% OV- on Chromosorb packed 00 Splitless. x.mm, tapered 00. x.mm, tapered, wool packed 00. x.mm, mm ID 00. x.mm, dual taper 00 Direct/On-Column. x.mm,.mm ID 00 SPME. x.mm, 0.mm ID 0 Model 0/0 Injector Split Injection x.mm, with frit 000 x.mm, Packed with 0% OV- on Chromosorb packed 00 x., unpacked 0 x.mm, with baffle 000 x.mm, wool packed 00 x.mm, w/cup unpacked 00 Splitless x.mm, straight 000 x.mm, SPME, 0.mm ID 0 Direct/On-Column x.mm, fused silica 0 x 0., universal flash, 0.mm ID columns 0 Model 0- SPI Direct/On-Column x.mm, direct injection, 0 x mm,.mm ID, frit 0 x.mm, wool packed 0 Model 0 Injector Split Injection x mm,.mm ID, unpacked 0 x mm,.mm ID, frit 0 x mm,.mm ID, packed 0 x mm, mm ID, split/splitless, wool packed 0 Splitless x mm, mm ID, unpacked 0 x mm, 0.mm ID, unpacked 0 x mm, 0.mm ID, temp ramp mode 0 Accessory Case for Varian GC Capillary Products We offer a clear plastic storage case with a foam insert. The foam easily stores your capillary accessories. The foam has been cut out to hold your Pk/ inlet liners, Pk/0 septa, Pk/0 ferrules, and Column nuts. Description Cat. No. GC Accessory Case for Varian 0-U

50 We are committed to the success of our Customers, Employees, and Shareholders through leadership in Life Science, High Technology, and Service The Service You Deserve 0 Easy Ordering Supelco offers many ways to easily place your order or inquire about an existing order. You can call, fax, or visit our web site hours a day, days a week. In the USA and Canada, please contact us at: Phone : 00-- / Fax: -- Web: sigma-aldrich.com/supelco Other countries, contact your local Sigma-Aldrich representative. For more information, visit sigma-aldrich.com Ready to order products? Searching for Material Safety Data Sheets or other product information? Need a new catalog? Many of your questions can be answered at our award winning web site. Go to sigma-aldrich.com/supelco to search for products, check up-to-the-minute availability, place orders, check order status, or directly trace the order shipment with a tracking number that is hot linked to the carrier s web site. You can check status and trace an order in two clicks! On-Time Delivery Still waiting for capillary GC columns that you ordered last week or last month? Not getting responsive customer service? Get the service you deserve today with products that meet your performance demands and are delivered when you need them. Same day shipping is our mission. Supelco s aim is to ship all stock products ordered by PM Eastern Time on the same day. Superior Support When you want additional information about a product, or help with a problem, our knowledgeable Technical Service chemists and our extensive library of free technical literature are just a telephone call, fax message, or away. We are always ready to respond to your questions, suggestions, criticisms, and changing needs. In the USA and Canada: please contact us at the following telephone numbers Monday - Friday during the hours of AM - PM Eastern Time Phone: / --0 Fax: / -- techservice@sial.com Other countries, contact your local Sigma-Aldrich representative. For more information, visit sigma-aldrich.com from the Company You Trust

51 Equity Capillary GC Columns Ordering Information Equity- Capillary GC Columns Phase: bonded; poly(dimethylsiloxane) Temp. Limits: 0. and 0.mm ID: -0 C to /0 C 0.mm ID: -0 C to 00/0 C (<=.µm d f ) -0 C to 0/0 C (>.µm d f ) Length (m) d f (µm) Cat. No. 0.0mm ID 0. 0-U 0. 0-U 0. 0-U 0.mm ID U 0. 0-U U U.0 0-U U U U 0.mm ID U 0. 0-U U U U U U U U U 0.mm ID U U 0. 0-U U.0 0-U U. 0-U 0. 0-U 0. 0-U.0 0-U U U.0 0-U U U Equity- Capillary GC Columns Phase: bonded; poly(% diphenyl/% dimethylsiloxane) Temp. Limits: 0. and 0.mm ID: -0 C to /0 C 0.mm ID: -0 C to 00/0 C(<=.µm d f ) -0 C to 0/0 C (>.µm d f ) Length (m) d f (µm) Cat. No. 0.0mm ID U 0.0mm ID U U U 0. 0-U 0.mm ID 0. 0-U U U U.0 0-U U U 0.mm ID 0. 0-U U U U U 0.0 -U 0.0 -U 0.mm ID 0. -U U U 0.0 -U. -U 0. -U 0.0 -U 0.0 -U.0 -U 0.0 -U 0.0 -U Equity-0 Capillary GC Columns Phase: bonded: poly(% cyanopropylphenyl/% dimethylsiloxane) Temp. Limits: 0. and 0.mm ID: subambient to 0 C 0.mm ID: subambient to 0 C Trademarks Agilent - Agilent Technologies Aroclor - Monsanto Co. CapSeal Bullet, Equity, SPB, Supelco, WAX, Supeltex, Therm-O-Ring, Thermogreen - Sigma Aldrich Co. Chromsorb - Manville Corp. OV - Ohio Valley Specialty Chemical Co. PerkinElmer - PerkinElmer Corp. Swagelok - Crawford Fitting Co. Viton - E.I. dupont de Nemours Length (m) d f (µm) Cat. No. 0.0mm ID 0.0 -U 0.mm ID 0. -U U U.0 -U 0.0 -U 0.0 -U 0.mm ID 0. -U U U.0 -U 0.0 -U 0.0 -U 0.mm ID 0. -U U.0 -U 0.0 -U. -U 0. -U

52 ARGENTINA Sigma-Aldrich de Argentina SA Av. Pueyrredon B CACU Buenos Aires Tel.: Fax: cservice@sigma-aldrich.com.ar AUSTRALIA Sigma-Aldrich Pty. Ltd. PO Box 0 Castle Hill, NSW Tel.: () Fax: () 00 Free Tel.: Free Fax: ausmail@sial.com AUSTRIA Sigma-Aldrich Handels GmbH Favoritner Gewerbering 0 A-00 Wien Tel.: Fax: sigma@sigma.co.at BELGIUM Sigma-Aldrich N.V./S.A. K. Cardijnplein B-0 Bornem Tel.: 0 0 Fax: 0 Free Tel.: 000 Free Fax: 000 becustsv@eurnotes.sial.com BRAZIL Sigma-Aldrich Química Brasil Ltda. Rua Ari Aps Jd. Pinheiros 0-00 São Paulo, SP Brasil Phone: 00 Fax: sigmabr@sigma-aldrich.com.br CANADA Sigma-Aldrich Canada Ltd. Winston Park Drive Oakville, Ontario LH J Tel.: 0 00 Fax: 0 Free Tel.:00 00 Free Fax:00 canada@sial.com CHINA Sigma-Aldrich China Inc., Shanghai Rep. Office Unit B, nd Floor, China Overseas Building No. Huai Hai Zhong Road Shanghai 0000 P.R.China Tel.: (-) - Fax: (-) - china@sial.com CZECH REPUBLIC Sigma-Aldrich s.r.o. Pobrezni 00 Praha Tel.: Fax: CZECustSV@eurnotes.sial.com DENMARK Sigma-Aldrich Denmark A/S Vejlegaardsvej B DK- Vallensbaek Strand Tel.: + 00 Fax: + 0 DenOrder@eurnotes.sial.com FINLAND Sigma-Aldrich Finland Y-A Kemia Oy Teerisuonkuja 0000 Helsinki Tel.: (0) 0 0 Fax: (0) 0 finorder@eurnotes.sial.com FRANCE Sigma-Aldrich Chimie S.a.r.l. L Isle d Abeau Chesnes - B.P. 0 St. Quentin Fallavier Cedex Tel.: 0 0 Fax: 0 0 Free Tel.: Free Fax: fradvsv@eurnotes.sial.com GERMANY Sigma-Aldrich Chemie GmbH Eschenstr. 0 Taufkirchen Tel.: 0 / -0 Fax: 0 / - Free Tel.:000 / 000 Free Fax:000 / DeOrders@eurnotes.sial.com GREECE Sigma-Aldrich (o.m.) Ltd. Argonafton Str. Ilioupoli, Athens Tel.: Fax: GRCustSV@SIALEUROPE HUNGARY Sigma-Aldrich Kft. Budapest Pf. 0/00 Magyarorszag Tel.: Fax: Free Tel.:0-0 Free Fax:0-0 info@sigma.sial.hu INDIA Sigma-Aldrich Chemical Private Limited Survey No. /, Sitharamapalaya Mahadevapura P.O. Bangalore 0 0 Tel.: -0-- Fax: india@sial.com sigmaindia@vsnl.com IRELAND Sigma-Aldrich Ireland Ltd. Airton Road Tallaght Dublin Tel.: (0) 000 Fax: (0) 00 Free Tel.: Free Fax: ElCustsv@eurnotes.sial.com ISRAEL Sigma-Aldrich Israel Ltd. Park Rabin Rehovot 00 Tel.: 0 Fax: 0 00 Free Tel.: sigisr@sigma.co.il ITALY Sigma-Aldrich S.r.l. Via Gallarate, 0 Milano Tel.: 0 0 Fax: 0 00 Free Tel.: itorder@eurnotes.sial.com JAPAN Sigma-Aldrich Japan K.K. Supelco Division Higashi Nihonbashi Sky Building F --, Higashi Nihonbashi, Chuo-ku Tokyo Tel.: (0) Fax: (0) KOREA Sigma-Aldrich Korea Ltd. PO Box, Yongin, -00 Tel.: Fax: 0 00 Tel.: 00 0 Fax: supelco@sial.co.kr MALAYSIA Sigma-Aldrich (M) Sdn. Bhd. 0, 0-, Jalan Awan Jawa Taman Yarl, Off Jin Klang Lama Kuala Lumpur 00 Tel.: 0- Fax: 0-0 sigalm@po.jaring.my MEXICO Sigma-Aldrich Química, S.A. de C.V. Calle Norte No. 0 Parque Industrial Toluca Toluca, Méx. Tel.: () 00 Fax: () 0 Free Tel.: Free Fax: mexico@sial.com THE NETHERLANDS Sigma-Aldrich Chemie B.V. Stationsplein E Postbus NL-0 AA Zwijndrecht Tel.: 0 0 Fax: 0 0 Free Tel.: Free Fax: nlcustsv@eurnotes.sial.com NEW ZEALAND Sigma-Aldrich Pty. Ltd. PO Box, Penrose Auckland Tel.: () Fax: () 00 Free Tel: 000 Free Fax:000 ausmail@sial.com NORWAY Sigma-Aldrich Norway AS Postboks Leirdal 0 Oslo Tel.: (+) 0 00 Fax: (+) 0 0 norsigma@sial.com POLAND Sigma-Aldrich Sp. z o.o. Szelagowska 0 - Poznan Tel.: (0) Fax: (0) plcustsv@eurnotes.sial.com PORTUGAL Sigma-Aldrich Química, S.A. Sucursal em Portugal Apartado -0 Sintra Tel.: Fax: 0 Free Tel.: Free Fax:00 0 encomendas: poorders@eurnotes.sial.com RUSSIA Sigma-Aldrich Russia TechCare Systems, Inc. Makarenko Str. / Building, Flat Moscow 00 Tel.: -0 Fax: -0 techcare@online.ru SINGAPORE Sigma-Aldrich Pte., Ltd. 0E Pasir Panjang Road #0-0 Citilink Warehouse Singapore Tel.: - 0 Fax: - sapl@sial.com SOUTH AFRICA CNR Kelly & Ackerman Streets Southern Life Industrial Park Unit Unit / Jet Park Tel.: Fax: Free Tel.: Free Fax: rsa@sial.com SPAIN Sigma-Aldrich Química, S.A. Ronda de Poniente, a Planta PO Box Correos 0 Tres Cantos Madrid Spain Tel.: Fax: Free Tel.: 00 0 Free Fax: pedidos:esorders@eurnotes.sial.com SWEDEN Sigma-Aldrich Sweden AB Solkraftsvägen C 0 Stockholm Tel.: 0-00 Fax: 0- Free Tel.: Free Fax: 00- sweorder@eurnotes.sial.com SWITZERLAND c/o Fluka Chemie GmbH Industriestrasse P.O. Box 0 Buchs Tel.: 0 Fax: 0 Free Tel.: Fluka@sial.com UNITED KINGDOM Sigma-Aldrich Company Ltd. Supelco UK Fancy Road, Poole Dorset BH QH Tel.: Fax: 0 Free Tel.:000 Free Fax: 000 ukorders@eurnotes.sial.com UNITED STATES Supelco North Harrison Road Bellefonte, PA -00 Tel.: Fax: Free Tel.:00 Free Fax:00 0 supelco@sial.com T00C-00 FAQ sigma-aldrich.com/supelco Order/Customer Service 00--, Fax supelco@sial.com Technical Service 00--0, --0 Fax 00--0, -- techservice@sial.com l North Harrison Road, Bellefonte, PA -00 l -- We are committed to the success of our Customers, Employees and Shareholders through leadership in Life Science, High Technology and Service. The SIGMA-ALDRICH Family 00 Sigma-Aldrich Co. Printed in USA. Supelco brand products are sold through Sigma-Aldrich, Inc. Sigma-Aldrich, Inc. warrants that its products conform to the information contained in this and other Sigma-Aldrich publications. Purchaser must determine the suitability of the product(s) for their particular use. Additional terms and conditions may apply. Please see reverse side of the invoice or packing slip.

Semivolatile Organic Reference Materials

Semivolatile Organic Reference Materials At-a-Glance Product Information from Restek US Environmental Protection Agency (EPA) Method 8270D outlines the analysis of semivolatile organic pollutants in solid waste, soil, water, and air matrices

More information

SUPELCO. Improved Performance for Cyanopropylphenyldimethylpolysiloxane (SPB-1701, SPB-1301) Capillary Columns

SUPELCO. Improved Performance for Cyanopropylphenyldimethylpolysiloxane (SPB-1701, SPB-1301) Capillary Columns Improved Performance for Cyanopropylphenyldimethylpolysiloxane (SPB-1701, SPB-1301) Capillary Columns L.M. Sidisky, Yizeng Ni, Greg Baney, Rodney George, Katherine K. Stenerson 01-0026 T401044 CFK Discussion

More information

The Role of the Carbon Cartridge in the One-Pass System

The Role of the Carbon Cartridge in the One-Pass System The Role of the Carbon Cartridge in the One-Pass System William Jones and Zoe Grosser, Horizon Technology, Inc. Key Words Solid phase extraction, spe, one-pass system, carbon cartridges Introduction Horizon

More information

Non-Potable Water A2LA Certificate

Non-Potable Water A2LA Certificate COLOR Color Biochemical Oxygen Demand (BOD); Carbonaceous DEMAND BOD; Chemical Oxygen Demand (COD); Total Organic Carbon (TOC) HEXAVALENT CHROMIUM INORGANIC NUTRIENTS LOW-LEVEL MERCURY METALS I & II METALS

More information

Faster Semivolatiles Analysis with a Scaled- Down Method and GC Accelerator Kit

Faster Semivolatiles Analysis with a Scaled- Down Method and GC Accelerator Kit Faster Semivolatiles Analysis with a Scaled- Down Method and GC Accelerator Kit Analysis times for semivolatile compounds can limit sample throughput and decrease overall lab productivity. You can significantly

More information

Rtx -CLPesticides Columns Reduce Analysis Time; Reduce System Maintenance

Rtx -CLPesticides Columns Reduce Analysis Time; Reduce System Maintenance Columns Reduce Analysis Time; Reduce System Maintenance 0 YEARS Turning Visions into Reality www.restek.com 00-- --00 and Fused Silica Columns Detect and confirm 0 common organochlorine pesticides simultaneously.

More information

STATE OF ILLINOIS ENVIRONMENTAL PROTECTION AGENCY NELAP - RECOGNIZED ENVIRONMENTAL LABORATORY ACCREDITATION. is hereby granted to

STATE OF ILLINOIS ENVIRONMENTAL PROTECTION AGENCY NELAP - RECOGNIZED ENVIRONMENTAL LABORATORY ACCREDITATION. is hereby granted to STATE OF ILLINOIS ENVIRONMENTAL PROTECTION AGENCY NELAP - RECOGNIZED ENVIRONMENTAL LABORATORY ACCREDITATION is hereby granted to ALS GROUP USA CORP. DBA ALS ENVIRONMENTAL - TX 10450 STANCLIFF ROAD, SUITE

More information

OREGON Environmental Laboratory Accreditation Program ORELAP Fields of Accreditation ALS Environmental - Simi Valley

OREGON Environmental Laboratory Accreditation Program ORELAP Fields of Accreditation ALS Environmental - Simi Valley MATRIX Reference Code Analyte Code Description ASTM C471M- 14 2014 ASTM D5504-12 2012 3964 Orthorhombic Cyclooctasulfur 4842 1-Propanethiol 6113 2,5-Dimethylthiophene 4544 2-Ethylthiophene 4843 2-Propanethiol

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares

More information

Semivolatile Organics Analysis Using an Agilent J&W HP-5ms Ultra Inert Capillary GC Column

Semivolatile Organics Analysis Using an Agilent J&W HP-5ms Ultra Inert Capillary GC Column Semivolatile Organics Analysis Using an Agilent J&W HP-5ms Ultra Inert Capillary GC Column Application Note Environmental Author Doris Smith and Kenneth Lynam Agilent Technologies, Inc. 285 Centerville

More information

317 Elm Street Milford, NH (603) Fax (603)

317 Elm Street Milford, NH (603) Fax (603) 317 Elm Street Milford, NH 03055 (603) 673-5440 Fax (603) 673-0366 Sales@chemservelab.com Friday, October 06, 2017 Domenic Carapella Greenplay Organics, LLC 6 Hawthorne Ave Merrick NY 11566 Project Name:

More information

DUAL CARTRIDGE SYSTEM FOR THE EXTRACTION OF ACIDS, BASES, AND NEUTRALS IN WATER

DUAL CARTRIDGE SYSTEM FOR THE EXTRACTION OF ACIDS, BASES, AND NEUTRALS IN WATER E N V I R O DUAL CARTRIDGE SYSTEM FOR THE EXTRACTION OF ACIDS, BASES, AND NEUTRALS IN WATER ENVIRO-CLEAN METHOD 8270 ENVIRO-CLEAN METHOD 8270 UCT, Inc. offers a unique, 2 cartridge system and extraction

More information

POTENTIAL VAPOR INTRUSION ENVIRONMENTAL

POTENTIAL VAPOR INTRUSION ENVIRONMENTAL POTENTIAL VAPOR INTRUSION ENVIRONMENTAL INVESTIGATION INVESTIGATION FOR: Michael Lee Bronxville School District 77 Pondfield Road Bronxville, NY 0708 SITE INVESTIGATED: Bronxville Elementary School Parking

More information

2. September 2015 Sub-Concrete Slab Soil Investigation

2. September 2015 Sub-Concrete Slab Soil Investigation To: Pam Barnett, RACER Ref. No.: 11109615 From: John-eric Pardys/kf/1 Date: October 30, 2015 Re: Summary of Sub-Concrete Slab Soil Investigation RACER Fredericksburg Facility Spotsylvania County, Virginia

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares

More information

Introducing New Functionalities in Liquid Stationary Phases in GC Columns for Confirming Organic Volatile Impurity Testing in Pharmaceutical Products.

Introducing New Functionalities in Liquid Stationary Phases in GC Columns for Confirming Organic Volatile Impurity Testing in Pharmaceutical Products. Introducing New Functionalities in Liquid Stationary Phases in GC Columns for Confirming Organic Volatile Impurity Testing in Pharmaceutical Products. CHRISTOPHER M. ENGLISH, CHRISTOPHER S. COX, FRANK

More information

Evaluating CLP and EPA Methods for Pesticides in Water Using Agilent J&W DB-CLP1/DB-CLP2 GC Columns

Evaluating CLP and EPA Methods for Pesticides in Water Using Agilent J&W DB-CLP1/DB-CLP2 GC Columns Evaluating CLP and EPA Methods for Pesticides in Water Using Agilent J&W DB-CLP/DB-CLP GC Columns Application Note Environmental Authors Doris Smith and Ken Lynam Agilent Technologies, Inc. Abstract The

More information

ANALYTICAL REPORT. Attn: Steve Johnson

ANALYTICAL REPORT. Attn: Steve Johnson ANALYTICAL REPORT TestAmerica Laboratories, Inc. N. Padre Island rive Corpus Christi, TX 0 Tel: ()- TestAmerica Job I: 0-00- Client For: Edwards Aquifer Authority North St. Mary's Street San Antonio, Texas

More information

Methods and Analytes Requiring Laboratory Certification Attachment 3

Methods and Analytes Requiring Laboratory Certification Attachment 3 s and s Requiring Laboratory Certification Attachment 3 Current as of July 1, 2011 Laboratory Certificates need to accurately reflect the methods performed and reported by the laboratory, including the

More information

Multi-residue Analysis for PAHs, PCBs and OCPs on Agilent J&W FactorFour VF-Xms

Multi-residue Analysis for PAHs, PCBs and OCPs on Agilent J&W FactorFour VF-Xms Multi-residue Analysis for PAHs, PCBs and OCPs on Agilent J&W FactorFour VF-Xms Application Note Author Laura Provoost Agilent Technologies, Inc. Introduction In multi-residue analysis different groups

More information

Low Bleed Stationary Phases for Gas Chromatography

Low Bleed Stationary Phases for Gas Chromatography Low Bleed Stationary Phases for Gas Chromatography Slide 4 Advantages of Low Bleed Phase Lower bleed compared to standard phases Better signal to noise (sensitivity) Higher upper temperature - shorter

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: 6701 Aberdeen Avenue, Suite #9, Lubbock, TX 79424

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares

More information

Date Issued: April 01, 2013 Expiration Date: June 30, 2013

Date Issued: April 01, 2013 Expiration Date: June 30, 2013 State of Florida Department of Health~Bureau of Public Health Laboratories I his is to certify that ALS ENVIRONMENTAL - SIMI VALLEY 2655 PARK CENTER DRIVE, SUITE A SIMI VALLEY, CA 93065 has complied with

More information

McCAMPBELL ANALYTICAL INC Willow Pass Road Pittsburg CA

McCAMPBELL ANALYTICAL INC Willow Pass Road Pittsburg CA Comparison of VOC : s, Target Lists, MAI Acenaphthene 83-32-9 Acetalaldehyde (Ethanal) 75-07-0 Acetone 67-64-1 Acetonitrile 75-05-8 Acetophenone 96-86-2 Acrolein (Propenal) 107-02-8 Acrylamide 79-06-1

More information

Appendix 2 Data Distributions for Contaminants in Water and Sediment Samples in Response to the Deepwater Horizon Oil Spill, 2010

Appendix 2 Data Distributions for Contaminants in Water and Sediment Samples in Response to the Deepwater Horizon Oil Spill, 2010 University of Nebraska - Lincoln DigitalCommons@University of Nebraska - Lincoln Publications of the US Geological Survey US Geological Survey 2013 Appendix 2 Data Distributions for Contaminants in Water

More information

Amec Foster Wheeler Environment & Infrastructure, Inc BIG SHANTY ROAD, NW, SUITE 100 KENNESAW, GEORGIA (770)

Amec Foster Wheeler Environment & Infrastructure, Inc BIG SHANTY ROAD, NW, SUITE 100 KENNESAW, GEORGIA (770) Dutch Valley Rd NE Worchester Dr NE Hillpine Dr NE Maddox Dr NE Lee St SW Maddox Dr NE Avery Dr NE E Park Ln NE Piedmont Ave NE Yorkshire Rd NE ³ Park Ln NE Westminster Dr NE Piedmont Way NE Westminster

More information

ANALYTICAL REPORT. Attn: Steve Johnson

ANALYTICAL REPORT. Attn: Steve Johnson ANALYTICAL REPORT TestAmerica Laboratories, Inc. N. Padre Island rive Corpus Christi, TX 0 Tel: ()- TestAmerica Job I: 0-- Client For: Edwards Aquifer Authority 00 E. Quincy San Antonio, Texas 0 Attn:

More information

Analysis of Semivolatile Organic Compounds Using the Agilent Intuvo 9000 Gas Chromatograph

Analysis of Semivolatile Organic Compounds Using the Agilent Intuvo 9000 Gas Chromatograph Analysis of Semivolatile Organic Compounds Using the Agilent Intuvo 9 Gas Chromatograph Application Note Author Matthew Giardina, Ph.D., Applications Chemist, Gas Phase Separations Division, Agilent Technologies,

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares

More information

ANALYTICAL REPORT. Attn: Dan Spector

ANALYTICAL REPORT. Attn: Dan Spector ANALYTICAL REPORT TestAmerica Laboratories, Inc. Benjamin Road Suite 0 Tampa, FL Tel: ()- TestAmerica Job I: 0-- Client Revision: For: Langan Engineering & Environmental Srvcs 0 NW th Court Suite 00 Miami

More information

Study of Residual Solvents in Various Matrices by Static Headspace

Study of Residual Solvents in Various Matrices by Static Headspace Application Note Abstract United States Pharmacopeia (USP) chapter is a widely used method for identifying and quantifying Organic Volatile Impurities (OVI) used in the production of pharmaceuticals.

More information

New Application Specific Columns for Semi-volatile and ECD Methods Lead the Way to Higher Productivity in Environmental Laboratories

New Application Specific Columns for Semi-volatile and ECD Methods Lead the Way to Higher Productivity in Environmental Laboratories New Application Specific Columns for Semi-volatile and ECD Methods Lead the Way to Higher Productivity in Environmental Laboratories Ken Lynam CSD Application Chemist Presentation Outline DB-UI 8270D columns

More information

The Determination of Residual Solvents in Pharmaceuticals Using the Agilent G1888 Network Headspace Sampler Application

The Determination of Residual Solvents in Pharmaceuticals Using the Agilent G1888 Network Headspace Sampler Application The Determination of Residual Solvents in Pharmaceuticals Using the Agilent G1888 Network Headspace Sampler Application Pharmaceuticals Author Roger L. Firor Agilent Technologies, Inc. 2850 Centerville

More information

Table 1 Soil and Groundwater Sampling Summary Table

Table 1 Soil and Groundwater Sampling Summary Table Table Soil and Groundwater Sampling Summary Table Phase II Investigation Consolidated Edison - Former kent Avenue Generating Station 0 Kent Avenue Brooklyn, NY Sample ID Date Installed Date Sample Collected

More information

MULTIRESIDUE ANALYSIS OF PRIORITY POLLUTANTS IN SURFACE WATERS USING EXACT MASS GC-TOF MS

MULTIRESIDUE ANALYSIS OF PRIORITY POLLUTANTS IN SURFACE WATERS USING EXACT MASS GC-TOF MS MULTIRESIDUE ANALYSIS OF PRIORITY POLLUTANTS IN SURFACE WATERS USING EXACT MASS GC-TOF MS Peter Hancock and Keith Worrall Waters Corporation, Manchester M22 5PP, UK INTRODUCTION The Dangerous Substances

More information

Selection of a Capillary

Selection of a Capillary Selection of a Capillary GC Column - Series 3 Mark Sinnott Application Engineer March 19, 2009 Page 1 Typical Gas Chromatographic System Mol-Sieve Traps Fixed Restrictors Regulators Injection Port Detector

More information

Headspace Technology for GC and GC/MS: Features, benefits & applications

Headspace Technology for GC and GC/MS: Features, benefits & applications Headspace Technology for GC and GC/MS: Features, benefits & applications Karima Baudin Oct 2015 Why use Headspace? Very Simple no to minimum sample prep Robust enhance uptime Non-detectable carry-over

More information

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System Application Note Residual Solvent Analysis of USP Method Residual Solvents on the Agilent 889 GC System Author Lukas Wieder, Jie Pan, and Rebecca Veeneman Agilent Technologies, Inc. 8 Centerville Road

More information

Ultra-Inert chemistry for Trace Level Analysis

Ultra-Inert chemistry for Trace Level Analysis Ultra-Inert chemistry for Trace Level Analysis Cikui Liang, Ph.D. Challenges and Needs of Today s Laboratories Challenges Qualification/quantification of trace samples Keep instrument up and running Needs

More information

Optimizing. Abstract: is standardd. procedures. altered to

Optimizing. Abstract: is standardd. procedures. altered to Optimizing Standard Preparation ANNE JUREK Abstract: Standardd preparation can often be a time consuming, tedious process. The opportunity for human error or inconsistencies between individual preparation

More information

METHOD 8270D SEMIVOLATILE ORGANIC COMPOUNDS BY GAS CHROMATOGRAPHY/MASS SPECTROMETRY (GC/MS)

METHOD 8270D SEMIVOLATILE ORGANIC COMPOUNDS BY GAS CHROMATOGRAPHY/MASS SPECTROMETRY (GC/MS) METHOD 8270D SEMIVOLATILE ORGANIC COMPOUNDS BY GAS CHROMATOGRAPHY/MASS SPECTROMETRY (GC/MS) SW-846 is not intended to be an analytical training manual. Therefore, method procedures are written based on

More information

Meeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS

Meeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS Application Note # CA 284780 Meeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS Abstract The analysis of semi-volatile organic compounds

More information

Selection of a Capillary GC Column

Selection of a Capillary GC Column Selection of a Capillary GC Column Mark Sinnott Application Engineer March 13, 2008 Page 1 Typical Gas Chromatographic System Mol-Sieve Traps Fixed Restrictors Regulators Injection Port Detector Electrometer

More information

So Many Columns! How Do I Choose? Daron Decker Chromatography Technical Specialist

So Many Columns! How Do I Choose? Daron Decker Chromatography Technical Specialist So Many Columns! How Do I Choose? Daron Decker Chromatography Technical Specialist GC Columns Wall Coated Open Tubulars Liquid phase coated capillaries Internal Diameter 0.05 0.53mm Length 5m 100m Porous

More information

Zebron MultiResidue GC Columns

Zebron MultiResidue GC Columns Zebron MultiResidue GC Columns A new Generation of Columns for Pesticide Analysis MultiResidue Optimized for pesticide, herbicide and insecticide analysis The use of many pesticides has been limited or

More information

Water Injections in GC - Does Water Cause Bleed?

Water Injections in GC - Does Water Cause Bleed? Water Injections in GC - Does Water Cause Bleed? Eberhardt Kuhn Applications Chemist April 4, 2001 Practical Advice and Useful Tips for the Analysis of Semivolatile Organics by GC and GC/MS 11:00 a.m.

More information

Validation of Environmental Water Methods on One System: Considerations for Sample Volume, Purge Parameters and Quality Control Parameters

Validation of Environmental Water Methods on One System: Considerations for Sample Volume, Purge Parameters and Quality Control Parameters Validation of Environmental Water Methods on One System: Considerations for Sample Volume, Purge Parameters and Quality Control Parameters Application Note Abstract Water quality laboratories across the

More information

Fast, Accurate Environmental Testing

Fast, Accurate Environmental Testing GC Columns Fast, Accurate Environmental Testing Using Zebron GC Columns Featuring Pesticides Diesel Range Organics Semivolatiles Dioxane And more.. www.phenomenex.com/environmental Semi-Volatile Organic

More information

US EPA Method with the Tekmar Lumin P&T Concentrator, AQUATek LVA and Agilent 7890B GC/5977A MS

US EPA Method with the Tekmar Lumin P&T Concentrator, AQUATek LVA and Agilent 7890B GC/5977A MS APPLICATION NOTE: TECHNOLOGY: INDUSTRY: AN1806 P+T VOC ENV US EPA Method 524.2 with the Tekmar Lumin P&T Concentrator, AQUATek LVA and Agilent 7890B GC/5977A MS Amy Nutter, Applications Chemist; Teledyne

More information

October 26, Dear Mr. White:

October 26, Dear Mr. White: ExxonMobil Environmental Services Company 38 Varick Street Brooklyn, New York 11222 October 26, 2011 New York State Department of Environmental Conservation Division of Environmental Remediation Remedial

More information

Hazardous Air Pollutant List By CAS Number

Hazardous Air Pollutant List By CAS Number Hazardous Air Pollutant List By CAS Number - Antimony compounds - Arsenic compounds - Beryllium compounds - Cadmium compounds - Chromium compounds Cobalt compounds - Coke oven emissions YES - Cyanide compounds

More information

Validation of USEPA Method Using a Stratum PTC and the New AQUATek 100 Autosampler

Validation of USEPA Method Using a Stratum PTC and the New AQUATek 100 Autosampler Validation of USEPA Method 524.2 Using a Stratum PTC and the New AQUATek 100 Autosampler Application Note Abstract Automation is the key to increasing laboratory productivity and minimizing costs. It is

More information

Zebron MultiResidue GC Columns

Zebron MultiResidue GC Columns Zebron MultiResidue GC Columns A New Generation of Columns for Pesticide Analysis MultiResidue Optimized for pesticide, herbicide and insecticide analysis The use of many pesticides has been limited or

More information

USP <467> Headspace Residual Solvent Assay with a HT3 Headspace Instrument

USP <467> Headspace Residual Solvent Assay with a HT3 Headspace Instrument Application Note Abstract The US Pharmacopeia recently released USP as the current monograph for determining residual solvents in pharmaceutical products by static headspace. The USP classified these

More information

Secrets of GC Column Dimensions

Secrets of GC Column Dimensions Secrets of GC Column Dimensions GC Columns and Consumables Simon Jones Application Engineer May 20, 2008 Slide 1 Secrets of GC Column Dimensions Do I have the right column phase? Resolution Equation Changes

More information

Residual solvents analysis using an Agilent Intuvo 9000 GC system

Residual solvents analysis using an Agilent Intuvo 9000 GC system Residual solvents analysis using an Intuvo GC system Technology advantage: simplified dual column analysis with Flow Chip modularity Introduction USP defines a method for analysis of residual solvents

More information

Thermal Desorption Technical Support

Thermal Desorption Technical Support Thermal Desorption Technical Support Note 86a: US EPA Method TO-17 for Monitoring Air Toxics in Ambient Air Using Sorbent Tubes and Automated, Cryogen-free Thermal Desorption Application Note Environmental,

More information

US EPA Method 8260 with the Tekmar Atomx XYZ P&T System and Agilent 7890B GC/5977A MS

US EPA Method 8260 with the Tekmar Atomx XYZ P&T System and Agilent 7890B GC/5977A MS Application Note US EPA Method 8260 with the Tekmar Atomx XYZ P&T System and Agilent 7890B GC/5977A MS Author Amy Nutter Applications Chemist, Teledyne Tekmar Abstract US EPA Method 8260 in conjunction

More information

Validation of USEPA Method Using a Stratum PTC, AQUATek 100 Autosampler, and Perkin-Elmer Clarus 600 GC/MS

Validation of USEPA Method Using a Stratum PTC, AQUATek 100 Autosampler, and Perkin-Elmer Clarus 600 GC/MS Validation of USEPA Method 524.2 Using a Stratum PTC, AQUATek 100 Autosampler, and Perkin-Elmer Clarus 600 GC/MS Application Note By: Nathan Valentine Abstract The US EPA developed Method 524.2¹, Measurement

More information

Table of Contents ~ 1 ~

Table of Contents ~ 1 ~ Table of Contents 0 JANUARY - JUNE TOXICS POLLUTANTS SUMMARY... SAMPLING PROCEDURES... METHOD OF SAMPLE DE-CHLORINATION... SAMPLE COMPOSITING... DATA VALIDATION... RESULTS... DISCUSSION OF RESULTS... INFLUENT

More information

A Generic Method for the Analysis of Residual Solvents in Pharmaceuticals Using Static Headspace-GC-FID/MS

A Generic Method for the Analysis of Residual Solvents in Pharmaceuticals Using Static Headspace-GC-FID/MS A Generic Method for the Analysis of Residual Solvents in Pharmaceuticals Using Static Headspace-GC-FID/MS Application Note Pharmaceuticals Authors Karine Jacq, Frank David, and Pat Sandra Research Institute

More information

environmental Rtx -CLPesticides and Rtx -CLPesticides2 Columns: The Ideal Confirmational Pair for Analyzing Polychlorinated Biphenyls (PCBs)

environmental Rtx -CLPesticides and Rtx -CLPesticides2 Columns: The Ideal Confirmational Pair for Analyzing Polychlorinated Biphenyls (PCBs) environmental #59120 Applications note Rtx -CLPesticides and Rtx -CLPesticides2 Columns: The Ideal Confirmational Pair for Analyzing Polychlorinated Biphenyls (PCBs) Polychlorinated biphenyls (PCBs) are

More information

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1 Application Note US EPA Method 524.2 with the Teledyne Tekmar Lumin P&T Concentrator and Agilent 7890B GC / 5977A MS Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1 Abstract US EPA Method

More information

The Suite for Environmental GC Analysis

The Suite for Environmental GC Analysis The Suite for Environmental GC Analysis SGE Environmental GC Columns Performance Selectivity Delivery Promise www.sge.com SGE Environmental GC Columns The Suite for Environmental GC Analysis SGE GC Columns

More information

ToxFAQs TM. Molecular Models

ToxFAQs TM. Molecular Models Search Index Home Contact Us CONTENTS Search ToxFAQs TM Index of ToxFAQs TM A B C D E F G H I J K L M N O P Q R S T U V W X Y Z Molecular Models NFPA 704 Labels ChemFinder Links Other Resources ToxFAQs

More information

EPA TO-17 Volatile Organic Compounds

EPA TO-17 Volatile Organic Compounds EPA TO-17 Volatile Organic Compounds Method TO-17 is used to analyze samples for volatile organic compounds collected on multi-bed sorbent tubes, which are thermally desorbed and cryo-focused on the capillary

More information

High Purity Chromasolv Solvents

High Purity Chromasolv Solvents Research Chemicals High Purity Chromasolv Solvents Part of Honeywell Research Chemical s Exclusive Riedel-de Haën Brand Portfolio The Chromasolv family of solvents are used in a variety of analytical applications

More information

Using Hydrogen as An Alternative Carrier Gas for US EPA 8260

Using Hydrogen as An Alternative Carrier Gas for US EPA 8260 Using Hydrogen as An Alternative Carrier Gas for US EPA 8260 Application Note Abstract Due to regional shortages and increasing costs of helium, the preferred carrier gas in gas chromatography, alternative

More information

Unique Selectivity: The Power of Ionic Liquid GC Columns

Unique Selectivity: The Power of Ionic Liquid GC Columns Unique Selectivity: The Power of Ionic Liquid GC Columns Leonard M. Sidisky, Jamie L. Desorcie, Gustavo Serrano Izaguirre, Daniel L. Shollenberger; Greg A. Baney, Katherine K. Stenerson, and Michael D.

More information

Presentation Title. Isotope Dilution: Where it doesn t work Where we should expand its use. August 10, David I. Thal Principal Chemist

Presentation Title. Isotope Dilution: Where it doesn t work Where we should expand its use. August 10, David I. Thal Principal Chemist Presentation Title Isotope Dilution: Subtitle Where / Author it works Where it doesn t work Where we should expand its use August 10, 2017 David I. Thal Principal Chemist Isotope Dilution - Definitions

More information

Detection of Volatile Organic Compounds in polluted air by an Agilent mini Thermal Desorber and an Agilent 5975T LTM GC/MS

Detection of Volatile Organic Compounds in polluted air by an Agilent mini Thermal Desorber and an Agilent 5975T LTM GC/MS Detection of Volatile Organic Compounds in polluted air by an Agilent mini Thermal Desorber and an Agilent 5975T LTM GC/MS Application Note Environmental Author Xiaohua Li Agilent Technologies (Shanghai)

More information

Analysis of Volatile Organic Compounds Using USEPA Method 8260 and the 4760 Purge and Trap and the 4100 Autosampler

Analysis of Volatile Organic Compounds Using USEPA Method 8260 and the 4760 Purge and Trap and the 4100 Autosampler Analysis of Volatile Organic Compounds Using USEPA Method 8260 and the 4760 Purge and Trap and the Introduction Although analysis of VOCs by purge and trap is considered a mature technique, advances in

More information

Analysis of Volatile Organic Compounds in Water and Soil by EPA Method 8260 with the Atomx Concentrator/Multimatrix Autosampler

Analysis of Volatile Organic Compounds in Water and Soil by EPA Method 8260 with the Atomx Concentrator/Multimatrix Autosampler Analysis of Volatile Organic Compounds in Water and Soil by EPA Method 8260 with the Atomx Concentrator/Multimatrix Autosampler Application Note By: Anne Jurek Abstract In order to determine the amount

More information

The Design of High Temperature Capillary Gas Chromatography Columns Based on Polydimethylsiloxane

The Design of High Temperature Capillary Gas Chromatography Columns Based on Polydimethylsiloxane The Design of High Temperature Capillary Gas Chromatography Columns Based on Polydimethylsiloxane Jarl Snider, D. J. Hotnisky, Kristi Sellers, Dinesh V. Patwardhan Ph. D. Restek Corporation www.restekcorp.com

More information

D2245

D2245 GC Columns and Accessories Thermo Scientific Chromatography Columns and Consumables 2014-2015 GC Column Selection by ASTM Method Selected ASTM methods are listed below with the appropriate Thermo Scientific

More information

Product Brief. - Hydrocarbons alkanes, alkenes, alkynes, dienes including natural gas, refinery gas, liquified petroleum gas

Product Brief. - Hydrocarbons alkanes, alkenes, alkynes, dienes including natural gas, refinery gas, liquified petroleum gas Agilent Porous Polymer PLOT Columns: New Products, Expanded Uses, Prices Cut in Half! Product Brief Need improved resolution of small volatile compounds? Didn't try a PLOT column due to high price, short

More information

Application Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS

Application Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS Application Note #1820230 Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS GC-MS Introduction USEPA Method 8270 [1] for semivolatiles is is used by by laboratories to measure

More information

TABLE OF CONTENTS. LIST OF FIGURES 1. Site Location Map 2. Assessment Map. LIST OF APPENDICES I. Laboratory Analytical Report

TABLE OF CONTENTS. LIST OF FIGURES 1. Site Location Map 2. Assessment Map. LIST OF APPENDICES I. Laboratory Analytical Report Additional Limited Phase II Environmental Site Assessment Report S&ME Project No. -- Former Baucom s Nursery Facility Omni / Trammell Crow Parcel December, 0 TABLE OF CONTENTS. INTRODUCTION.... BACKGROUND....

More information

Choosing the Correct GC Column Dimensions and Stationary Phase

Choosing the Correct GC Column Dimensions and Stationary Phase Choosing the Correct GC Column Dimensions and Stationary Phase Daron Decker Chromatography Technical Specialist Page 1 Nothing is useless it can always serve as a bad example Custom Column: 150 m x 250

More information

Should you have any questions, please contact our office at (813)

Should you have any questions, please contact our office at (813) October 14, 2013 Comprehensive Engineering Services, Inc. 201 S. Orange Avenue, Suite 1300 Orlando, Florida 32801 Attn: RE: Mr. John F. Petrosillo, P.E. Project Manager Draft Level II Field Screening Report

More information

Developing Large Volume Injection (LVI) in Split / Splitless Inlets. Philip J. Koerner Phenomenex Inc. NEMC 2014

Developing Large Volume Injection (LVI) in Split / Splitless Inlets. Philip J. Koerner Phenomenex Inc. NEMC 2014 Developing Large Volume Injection (LVI) in Split / Splitless Inlets Philip J. Koerner Phenomenex Inc. NEMC 2014 Goal To produce a method that provides the largest response of analytes that will produce

More information

Page 1 of 7 ADEQ Water Div NPDES 9/18/2017 8:52 AM

Page 1 of 7 ADEQ Water Div NPDES 9/18/2017 8:52 AM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 Page 1 of 7 ADEQ Water Div NPDES 9/18/2017 8:52 AM CALCULATIONS OF ARKANSAS WATER QUALITY-BASED

More information

Validation of Volatile Organic Compound by USEPA. Method 8260C. Application Note. Abstract. Introduction. Experimental-Instrument Conditions

Validation of Volatile Organic Compound by USEPA. Method 8260C. Application Note. Abstract. Introduction. Experimental-Instrument Conditions Validation of Volatile Organic Compound by USEPA Method 8260C Application Note Abstract In order to determine the concentration of volatile organic compounds (VOCs) in water and soil matrices the USEPA

More information

High Throughput Multi-Residue Screening of Drinking Water using the SPE-DEX~ and Pegasus GC-TOF-MS

High Throughput Multi-Residue Screening of Drinking Water using the SPE-DEX~ and Pegasus GC-TOF-MS Application Note No. 098 High Throughput Multi-Residue Screening of Drinking Water using the SPE-DEX~ and Pegasus GC-TOF-MS Steve Scott, Thames Water, Reading, UK Diane Turner. Introduction In cases of

More information

EPA Region III BTAG Freshwater Sediment Screening Benchmarks 8/2006. Bioaccumulative o

EPA Region III BTAG Freshwater Sediment Screening Benchmarks 8/2006. Bioaccumulative o 71-55-6 1,1,1-Trichloroethane 0.0302 a,b 1 Volatile 79-34-5 1,1,2,2-Tetrachloroethane 1.36 a,b 1 Volatile 127-18-4 1,1,2,2-Tetrachloroethylene (PCE) 0.468 a,b 1 Volatile 79-00-5 1,1,2-Trichloroethane 1.24

More information

A Comparison of Volatile Organic Compound Response When Using Nitrogen as a Purge Gas

A Comparison of Volatile Organic Compound Response When Using Nitrogen as a Purge Gas A Comparison of Volatile Organic Compound When Using Nitrogen as a Gas Application Note By: Anne Jurek Abstract For many years Helium has been the gas of choice for purging Volatile Organic Compounds (VOCs).

More information

Methanol Extraction of high level soil samples by USEPA Method 8260C

Methanol Extraction of high level soil samples by USEPA Method 8260C Methanol Extraction of high level soil samples by USEPA Method 8260C Abstract In order to determine the concentration of Volatile Organic Compounds (VOCs) in soil and waste samples the USEPA developed

More information

Appendix J NPRI Substances

Appendix J NPRI Substances Appendix J NPRI Substances Appendix 1 Alphabetical Listing of NPRI Substances for 2005 The substances are listed in six parts. The reporting criteria for the substances listed in each Part differ and are

More information

Column Dimensions. GC Columns and Consumables. Mark Sinnott Application Engineer. March 12, 2010

Column Dimensions. GC Columns and Consumables. Mark Sinnott Application Engineer. March 12, 2010 Secrets of GC Column Dimensions GC Columns and Consumables Mark Sinnott Application Engineer Folsom California March 12, 2010 Page 1 Secrets of GC Column Dimensions Do I have the right column phase? Resolution

More information

Analysis of Volatile Organic Compounds in Soil Samples by EPA Method 8260 with The Stratum PTC and SOLATek 72 Multi-Matrix Autosampler

Analysis of Volatile Organic Compounds in Soil Samples by EPA Method 8260 with The Stratum PTC and SOLATek 72 Multi-Matrix Autosampler Analysis of Volatile Organic Compounds in Soil Samples by EPA Method 8260 with The Stratum PTC and SOLATek 72 Multi-Matrix Autosampler Application Note By: Teri Dattilio Introduction Purge and Trap concentration

More information

Agilent UltiMetal Plus Stainless Steel Deactivation for Tubing, Connectors, and Fittings

Agilent UltiMetal Plus Stainless Steel Deactivation for Tubing, Connectors, and Fittings Agilent UltiMetal Plus Stainless Steel Deactivation for Tubing, Connectors, and Fittings Technical Overview Introduction Modern GC and GC/MS instruments are important analytical tools for accurate and

More information

EAA STAFF ATTACHMENT 13 DECEMBER Appendix D Analytical Data Validation Discussion

EAA STAFF ATTACHMENT 13 DECEMBER Appendix D Analytical Data Validation Discussion Appendix D Analytical Data Validation Discussion Introduction This appendix provides an overview of the EAA s post analyses review of the TestAmerica analytical data set. In general, the data are considered

More information

Application Note 116 Monitoring VOCs in Ambient Air Using Sorbent Tubes with Analysis by TD-GC/MS in Accordance with Chinese EPA Method HJ

Application Note 116 Monitoring VOCs in Ambient Air Using Sorbent Tubes with Analysis by TD-GC/MS in Accordance with Chinese EPA Method HJ Application Note Monitoring VOCs in Ambient Air Using Sorbent Tubes with Analysis by TD-GC/MS in Accordance with Chinese EPA Method HJ -3 Application Note Abstract This application note demonstrates the

More information

Improve lives IT S ABOUT IMPROVING PEOPLE S LIVES IT S ABOUT INTENT

Improve lives IT S ABOUT IMPROVING PEOPLE S LIVES IT S ABOUT INTENT THE DESIGNERS ROLE Different roles Improve lives IT S ABOUT IMPROVING PEOPLE S LIVES IT S ABOUT INTENT INTENT 1) DEFINE THE INTENT The road to hell THE ROAD TO HELL IS PAVED WITH GOOD INTENTIONS Toothbrush

More information

Certificate of Analysis

Certificate of Analysis Certificate of Analysis 2139 Certificate Number: 13-92896 Date: 27/11/2013 Client: Stainton Quarry Stainton Quarry Stainton Barnard Castle DL12 8RB Our Reference: 13-92896 Client Reference: Description:

More information

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software High Efficiency GC Columns Page 1 Variables for Shortening Run Times Stationary Phase Shorten Column Length

More information

Simultaneous dual capillary column headspace GC with flame ionization confirmation and quantification according to USP <467> Application Note

Simultaneous dual capillary column headspace GC with flame ionization confirmation and quantification according to USP <467> Application Note Simultaneous dual capillary column headspace GC with flame ionization confirmation and quantification according to USP Application Note Joseph M. Levy Michael Kraft Abstract Agilent Equipment 7890A

More information

Introduction to Gas Chromatography

Introduction to Gas Chromatography Introduction to Gas Chromatography 31-1 Objectives To know what is chromatography To understand the mechanism of compound separation To know the basic of gas chromatography system 31-2 Chromatography Definition

More information

Validation of USEPA Method 8260C Using Teledyne Tekmar Atomx, and Perkin-Elmer Clarus 600 GC/MS

Validation of USEPA Method 8260C Using Teledyne Tekmar Atomx, and Perkin-Elmer Clarus 600 GC/MS Validation of USEPA Method 8260C Using Teledyne Tekmar Atomx, and Perkin-Elmer Clarus 600 GC/MS Application Note By Tyler Trent Abstract In order to determine the concentration of volatile organic compounds

More information