QUALIFICATION OF FLOW CONDTIONING DEVICES ACCORDING TO THE NEW API 14.3 PART 2 PROCEDURE. Klaus J. Zanker and Dale Goodson. Daniel Industries, Inc.
|
|
- Neal Francis
- 6 years ago
- Views:
Transcription
1 QUALIFICATION OF FLOW CONDTIONING DEVICES ACCORDING TO THE NEW API 14.3 PART 2 PROCEDURE. Klaus J. Zanker and Dale Goodson Daniel Industries, Inc.
2 Old Tube Bundle A D a 1. a/d < 1/4 2. L/a > 1 3. A < 1/16(π D 2 /4) 4. Tubes any size - symmetrical 5. Tubes any shape 6.Tubes mounted into end rings 7. Tubes welded together 8. Tubes thin walled 9. All tubes mounted axially
3 New Tube Bundle Tube bundle OD Items 1, 2, 3, 4, 5, & 6 no longer apply, only 19 tube uniform concentric tube bundle allowed All tubes must touch one another Tubes must be welded together OD >.95 D t < 2.5 % of D Tube wall thickness = t
4 API Type Approval Requirements Baseline Calibration, evaluating performance of test facility To prove that the mechanical baseline configuration is valid, the baseline CD values should lie within the 95% confidence interval for the RG equation. Standard does not demand an accredited facility
5 Disturbance Tests Good Flow Conditions - test evaluating impact of flow conditioner on fully developed velocity profile. Two 9 Elbows in Perpendicular Planes - testing of flow conditioner performance in handling combination of a modest swirl and a non-symmetrical velocity profile. Gate Valve 5% Closed - test evaluating flow conditioner performance in strongly non-symmetrical velocity profile. High Swirl - test assessing flow conditioner performance in flows with high swirl angle (over 25 ).
6 Additional Tests Orifice b ratio: Check swirl test at β=.4 and β=7 Reynolds Number Sensitivity: Test at two ranges 1 4 < Re <5 x 1 5 and Re > 1 6 with approximately a 7:1 ratio. Scaling: Test at two sizes selected from D < 4 and D > 8
7 Zanker Plate Design Zanker straightener 1959 at BHRA, NEL conference in 196, was included in ISO 5167 in 198 Mitsubishi in 1973 US patent Elizabeth Laws in 1992 Modified Zanker: Thick plate, no honeycomb
8 Flow Straightener
9 Zanker Plate
10
11
12 .67b : Good Flow Conditions.8 % Deviation of Actual CD from Baseline CD Zanker Plate Distance in Pipe Diameters from the Orifice Plate 3 O'Clock 12 O'Clock 9 O'Clock
13 67b : Two 9 Elbows in Perpendicular Planes 17 D Meter Tube.8 % Deviation of Actual CD from Baseline CD Zanker Plate Distance in Pipe Diameters from the Orifice Plate 3 O'Clock 12 O'Clock 9 O'Clock Error Band
14 .67b : Two 9 Elbows in Perpendicular Planes 29D Meter Tube.8 % Deviation of Actual CD from Baseline CD Zanker Plate Distance in Pipe Diameters from the Orifice Plate 3 O'Clock 12 O'Clock 9 O'Clock Error Band
15 .67b : Two 9 Elbows in Perpendicular Planes 45D Meter Tube.8 % Deviation of Actual CD from Baseline CD Zanker Plate Distance in Pipe Diameters from the Orifice Plate 3 O'Clock 12 O'Clock 9 O'Clock Error Band
16 .67b : 5% Closed Gate Valve 17D Meter Tube.8 % Deviation of Actual CD from Baseline CD Zanker Plate Distance in Pipe Diameters from the Orifice Plate 3 O'Clock 12 O'Clock 9 O'Clock Error Band
17 .67b : 5% Closed Gate Valve 29D Meter Tube.8 % Deviation of Actual CD from Baseline CD Zanker Plate Distance in Pipe Diameters from the Orifice Plate 3 O'Clock 12 O'Clock 9 O'Clock Error Band
18 .67b : 5% Closed Gate Valve 45D Meter Tube.8 % Deviation of Actual CD from Baseline CD Zanker Plate Distance in Pipe Diameters from the Orifice Plate 3 O'Clock 12 O'Clock 9 O'Clock Error Band
19 Swirl Producing Vane
20 Swirl produced 35 3 Swirl angle (degrees) Distance from pipe wall (in)
21 .67b : 17 D Meter Tube : 32 swirl.8 % Deviation of Actual C D from Baseline CD Distance of Zanker Plate in Pipe Diameters from the Orifice 3 O'Clock 12 O'Clock 9 O'Clock Error Band
22 .67b : 32º Swirl : 29D Meter Tube % Deviation of Actual CD from Baseline CD Zanker Plate Distance in Pipe Diameters from the Orifice Plate 3 O'Clock 12 O'Clock 9 O'Clock Error Band
23 .67b : 32º Swirl : 45D Meter Tube % Deviation of Actual CD from Baseline CD Zanker Plate Distance in Pipe Diameters from the Orifice Plate 3 O'Clock 12 O'Clock 9 O'Clock Error Band
24 .4 b : 17 D Meter Tube : 32 swirl.8 % Deviation of Actual CD from Baseline C D Distance of Zanker Plate in Pipe Diameters from the Orifice 3 O'Clock 12 O'Clock 9 O'Clock Error Band
25 .4 b : 29 D Meter Tube : 32 swirl % Deviation of Actual CD from Baseline CD Distance of Zanker Plate in Pipe Diameters from the Orifice 3 O'Clock 12 O'Clock 9 O'Clock Error Band
26 .4 b : 45 D Meter Tube : 32 swirl.8 % Deviation of Actual CD from Baseline CD Distance of Zanker Plate in Pipe Diameters from the Orifice 3 O'Clock 12 O'Clock 9 O'Clock Error Band
27 .67 b : 4" OFU: High Reynolds Number: Good Flow Condition.8 % Deviation of Actual CD from Baseline CD Distance of Zanker Plate in Pipe Diameters from the Orifice 3 O'Clock 9 O'Clock Error Band
28 .67 b : 8" OFU : Good Flow Condition.8 % Deviation of Actual CD from Baseline CD Distance of Zanker Plate in Pipe Diameters from the Orifice 3 O'Clock 9 O'Clock Error Band
29 4' OFU :.67b :Ceesi & Daniel Baselines CD E+ 5.E+5 1.E+6 1.5E+6 2.E+6 2.5E+6 3.E+6 3.5E+6 Pipe Reynolds Number CEESI Daniel RG Equa. +Uncert. -Uncert
30 Good Flow Conditions : 4" Hi R D & Low R D : 8 inch Deviation of Actula C D from Baseline C D Distance of Zanker Plate from the Orifice Plate in Pipe Diameters Lo Rd Hi Rd +.23% -.23% 8 inch
31 .67 b : 8" OFU : 5% Closed Gate Valve : 17D Meter Tube.8 % Deviation of Actual C D from Baseline C D Distance of Zanker Plate in Pipe Diameters from the Orifice 12 O'Clock 6 O'Clock Error Band
32 .67 b : 8" OFU : 5% Closed Gate Valve : 29D Meter Tube.8 % Deviation of Actual CD from Baseline CD Distance of Zanker Plate in Pipe Diameters from the Orifice 12 O'Clock 6 O'Clock Error Band
33 .67 b : 8" OFU : 5% Closed Gate Valve : 45D Meter Tube.8 % Deviation of Actual CD from Baseline CD Distance of Zanker Plate in Pipe Diameters from the Orifice 12 O'Clock 6 O'Clock Error Band
34 Conclusions The three pairs of taps are not always all in tolerance The high swirl test requires better definition The Zanker Flow Conditioner has passed all the type approval tests This makes a reasonably priced nonproprietary flow conditioner available to the industry
35 Conclusions Recommendation: - use 17D meter tube with conditioner 7.5D from the orifice plate, as this arrangement passed all tests The conditioner can be used as follows: Beta up to 7 with any disturbance in any pipe size with no upper limit on Reynolds Number
NORTH SEA FLOW MEASUREMENT WORKSHOP 2004 In. St Andrews, Scotland
NORTH SEA FLOW MEASUREMENT WORKSHOP 2004 In St Andrews, Scotland From the 26 th to 28 th October, 2004 Tests of the V-Cone Flow Meter at Southwest Research Institute and Utah State University in Accordance
More informationThe Expansibility Factor Equations in ISO and ISO : Do They Deliver What They Promise?
The Expansibility Factor Equations in ISO 567-2 and ISO 567-4: Do They Deliver What They Promise? Michael Reader-Harris, NEL INTRODUCTION The expansibility factor equations in ISO 567-2:2003 [] and ISO
More information405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook
Reference Manual 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book and Flow Handbook www.rosemount.com Reference Manual 405 and 1595 405 Compact Orifice Series and 1595 Conditioning
More information405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook
405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book and Flow Handbook www.rosemount.com 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book NOTICE Read
More informationDischarge coefficient behaviour in presence of four perforated plates flow conditioners - Numerical investigation Part 1-
17 International Congress of Metrology, 5 (215) DOI: 1.151/ metrolo gy/ 2155 C Owned by the authors, published by EDP Sciences, 215 Discharge coefficient behaviour in presence of four perforated plates
More informationDischarge Coefficient Behaviour in Presence of Four Perforated Plates Flow Conditioners
Proceedings of the 4 th International Conference of Fluid Flow, Heat and Mass Transfer (FFHMT'17) Toronto, Canada August 21 23, 2017 Paper No. 183 DOI: 10.11159/ffhmt17.183 Discharge Coefficient Behaviour
More information405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook
405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book and Flow Handbook www.rosemount.com 405 and 1595 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test
More informationLaboratory work No 2: Calibration of Orifice Flow Meter
Laboratory work No : Calibration of Orifice Flow Meter 1. Objective Calibrate the orifice flow meter and draw the graphs p = f 1 (Q) and C d = f (Re ).. Necessary equipment 1. Orifice flow meter. Measuring
More informationFINAL DRAFT: October 25, 2010 API TECHNICAL REPORT FUEL GAS MEASUREMENT. FINAL DRAFT: October 25, 2010 Page 0
FINAL DRAFT: October 25, 2010 API TECHNICAL REPORT FUEL GAS MEASUREMENT FINAL DRAFT: October 25, 2010 Page 0 Foreword Add API boiler plate FINAL DRAFT: October 25, 2010 Page 1 TABLE OF CONTENTS Introduction...
More informationProcess Gas Flow Measurement and Performance Evaluation API TECHNICAL REPORT 2571 SECOND EDITION DRAFT, FEBRUARY 2018
Process Gas Flow Measurement and Performance Evaluation API TECHNICAL REPORT 2571 SECOND EDITION DRAFT, FEBRUARY 2018 (Note: modify document as needed once final proposal on name change is agreed, i.e.
More informationLecture 13 Flow Measurement in Pipes. I. Introduction
Lecture 13 Flow Measurement in Pipes I. Introduction There are a wide variety of methods for measuring discharge and velocity in pipes, or closed conduits Many of these methods can provide very accurate
More informationME332 FLUID MECHANICS LABORATORY (PART I)
ME332 FLUID MECHANICS LABORATORY (PART I) Mihir Sen Department of Aerospace and Mechanical Engineering University of Notre Dame Notre Dame, IN 46556 Version: January 14, 2002 Contents Unit 1: Hydrostatics
More informationSmart DP Flow Metering A summary of Established Technology and Latest Innovation. Gary Fish
Smart DP Flow Metering A summary of Established Technology and Latest Innovation Gary Fish DP Flow Measurement Established Technology Large range of line sizes, materials, connection interfaces, etc Customised
More informationMajor and Minor Losses
Abstract Major and Minor Losses Caitlyn Collazo, Team 2 (1:00 pm) A Technovate fluid circuit system was used to determine the pressure drop across a pipe section and across an orifice. These pressure drops
More informationConditioning of swirling and stratified pipe-flow: Analysis with laser-doppler velocimetry
Conditioning of swirling and stratified pipe-flow: Analysis with laser-doppler velocimetry Denis F. Hinz 1, Simon Graner 1, and Christian Breitsamter 2 1 Kamstrup A/S, Industrivej 28, Stilling, 8660 Skanderborg,
More informationExperiment (4): Flow measurement
Experiment (4): Flow measurement Introduction: The flow measuring apparatus is used to familiarize the students with typical methods of flow measurement of an incompressible fluid and, at the same time
More informationWater Circuit Lab. The pressure drop along a straight pipe segment can be calculated using the following set of equations:
Water Circuit Lab When a fluid flows in a conduit, there is friction between the flowing fluid and the pipe walls. The result of this friction is a net loss of energy in the flowing fluid. The fluid pressure
More informationV-Cone Flowmeter DATASHEET
V-Cone Flowmeter ATASHEET JUNHO 013 IntraCone Cone Flow Meter Type: ICM etail: Cone-Element Technical Information 05/011 FLOW THE SPECIALIST IN LEVEL AN FLOW Cone Flow Meter Technical Information Intra-Automation
More informationFlow Measurement in Pipes and Ducts COURSE CONTENT
Flow Measurement in Pipes and Ducts Dr. Harlan H. Bengtson, P.E. COURSE CONTENT 1. Introduction This course is about measurement of the flow rate of a fluid flowing under pressure in a closed conduit.
More informationCOMPRESSOR HASN T RUN THIS QUIETLY OR SMOOTHLY IN 18 YEARS OF OPERATION A CASE STUDY ABOUT FIELD DE-TUNING OF MECHANICAL RESONANCE ON FIXED SPEED SCREW COMPRESSOR PACKAGES Bryan P. Fofonoff P.Eng. 1 Abnil
More informationUniversal type Port size AS13 1F-M3. M3 x 0.5 M5 x 0.8 AS23 1F-01 AS23 1F-02 AS33 1F-02 AS33 1F-03 AS43 1F-04 R 1/8 R 1/4 R 1/4 R 3/8 R 1/2
Minimizes installation time and cost Reduces the mounting height and enables compact machinery design. Effective area is larger than the former model. Tube swivels 0 Universal type permits 0 piping swivel.
More informationFlowmeter Discharge Coefficient Estimation
Bankston 1 Flowmeter Discharge Coefficient Estimation Elizabeth Bankston Team 1 Abstract An Edibon FME18 Flow Meter demonstration system was used to obtain experimental values for this experiment. The
More informationALASTAIR MCLACHLAN Applications Cameron
ALASTAIR MCLACHLAN Applications Cameron Have worked in the oil and gas flow measurement industry for 27 years primarily in custody transfer measurement using ultrasonic meters. Joined Cameron Caldon Ultrasonics
More informationLarge Rocket Engine Environments
Balanced Flow Metering and Conditioning Technology for Fluid Systems (Space Liquid Propulsion Systems) for 2006 Instrumentation Symposium for the Process Industries Anthony R. Kelley EV23 Advanced Sensors
More informationME 4600:483 Lab Notes Revised 11/16/2015. Flow Measurement
Table of Contents Flow Measurement Flow Measurement... 1 I. Objective... 1 II. Apparatus... 1 III. Principles and Background... 1 Pitot-Static Tubes... 2 Orifice Plates and Unrecoverable Losses... 4 Flow
More informationA REVIEW OF THE V-CONE METER FOR NATURAL GAS FLOWS
A REVIEW OF THE V-CONE METER FOR NATURAL GAS FLOWS Szabo, J.L. Winarski, C.P. Hypnar, P.R. Novacorp International Consulting Inc. Southern California Edison ABB Impell Corporation Conference: OMAE 99 June
More informationSELECCIÓN DE CAUDALIMETROS. Tablas de Fabricantes
SELECCIÓN DE CAUDALIMETROS Tablas de Fabricantes Flow Meter Selection Table http://www.instrumart.com/content.aspxcontentid=219 Página 1 de 1 17/09/2007 KEY Best for this application OK with some exceptions
More informationInstallation effects on an ultrasonic flow meter with implications for self diagnostics
Flow Measurement and Instrumentation 11 (2000) 109 122 www.elsevier.com/locate/flowmeasinst Installation effects on an ultrasonic flow meter with implications for self diagnostics Carl Carlander *, Jerker
More informationAn Essential Requirement in CV Based Industrial Appliances.
Measurement of Flow P M V Subbarao Professor Mechanical Engineering Department An Essential Requirement in CV Based Industrial Appliances. Mathematics of Flow Rate The Scalar Product of two vectors, namely
More informationHEAT TRANSFER ENHANCEMENT IN HEAT EXCHANGER USING TANGENTIAL INJECTOR TYPE SWIRL GENERATOR
HEAT TRANSFER ENHANCEMENT IN HEAT EXCHANGER USING TANGENTIAL INJECTOR TYPE SWIRL GENERATOR Hanumant Jagdale Department of Mechanical Engineering, MIT, Aurangabad, India Subhash Lahane Department of Mechanical
More informationSudden Expansion Exercise
Sudden Expansion Exercise EAS 361, Fall 2009 Before coming to the lab, read sections 1 through 4 of this document. Engineering of Everyday Things Gerald Recktenwald Portland State University gerry@me.pdx.edu
More informationPOWER UNDERSTANDING MEASUREMENT UNCERTAINTY IN DP FLOW DEVICES
Proceedings of the ASME 2014 Power Conference POWER2014 July 28-31, 2014, Baltimore, Maryland, USA POWER2014-32205 UNDERSTANDING MEASUREMENT UNCERTAINTY IN DP FLOW DEVICES Michael S. Hering Rosemount DP
More informationFLOW MEASUREMENT. INC 102 Fundamental of Instrumentation and Process Control 2/2560
FLOW MEASUREMENT INC 102 Fundamental of Instrumentation and Process Control 2/2560 TABLE OF CONTENTS A. INTRODUCTION B. LOCAL FLOW MEASUREMENT B.1 Particle Image Velocimetry (PIV) B.2 Laser doppler anemometry
More information507F. Multi-Port Sanitary Ball Valve. Full Port ISO 5211 Mounting Pad. For Automated & Manual Service. Pharmaceutical. Bio-Technology.
507F Multi- Sanitary Ball Valve Full ISO 5 Mounting Pad For Automated & Manual Service Pharmaceutical Bio-Technology Cosmetic Food & Beverage The 507F Series //5-Way Sanitary Ball Valve The 507F is a true
More informationEVALUATION OF A CLOSE COUPLED SLOTTED ORIFICE, ELECTRICAL IMPEDANCE, AND SWIRL FLOW METERS FOR MULTIPHASE FLOW. A Thesis MUHAMMET CEVIK
EVALUATION OF A CLOSE COUPLED SLOTTED ORIFICE, ELECTRICAL IMPEDANCE, AND SWIRL FLOW METERS FOR MULTIPHASE FLOW A Thesis by MUHAMMET CEVIK Submitted to the Office of Graduate and Professeional Studies of
More information) where the inlet pressure ( P 1
Cone DP Meter Calibration Issues Authors: Casey Hodges, Charles Britton, William Johansen & Richard Steven CEESI, 54043 Weld County Road 37, Nunn, CO 80648 Email: chodges@ceesi.com, Telephone: US 970-897-2711
More informationMeasurement of fluid flow in closed conduits
BRITISH STANDARD BS 1042-2.2: 1983 ISO 7145:1982 Measurement of fluid flow in closed conduits Part 2: Velocity area methods Section 2.2 Method of measurement of velocity at one point of a conduit of circular
More informationExperiment No.4: Flow through Venturi meter. Background and Theory
Experiment No.4: Flow through Venturi meter Background and Theory Introduction Flow meters are used in the industry to measure the volumetric flow rate of fluids. Differential pressure type flow meters
More informationABB Flowmeters Review of industrial processing flowmeters
White paper ABB Flowmeters Review of industrial processing flowmeters Understanding flowmeters and their pros and cons By Ron DiGiacomo, ABB Measurement Products One of the most critical measurements in
More informationFlow rate and mass flow rate
EEN-E1040 Measurement and control of energy systems Flow measurements / 14 Sep 2017 WELCOME! v. 01 / T. Paloposki Flow rate and mass flow rate Consider the system shown here 1 Volume flow rate through
More informationPROCEEDINGS American School of Gas Measurement Technology 2003 PROCEEDINGS. PAGE xxv AMERICAN SCHOOL OF GAS MEASUREMENT TECHNOLOGY
PROCEEDINGS 2003 American School of Gas Measurement Technology PAGE xxv FUNDAMENTALS OF GAS LAWS John Chisholm Texas A&M University Kingsville Chemical & Natural Gas Engineering Kingsville, TX 78363 INTRODUCTION
More informationPrediction of Performance Characteristics of Orifice Plate Assembly for Non-Standard Conditions Using CFD
International Journal of Engineering and Technical Research (IJETR) ISSN: 2321-0869, Volume-3, Issue-5, May 2015 Prediction of Performance Characteristics of Orifice Plate Assembly for Non-Standard Conditions
More informationFlow Measurement. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/22 Siemens FI
Function All are based on Faraday s law of induction: U M = B v d k U M = Measured voltage induced in the medium perpendicular to the magnetic field and the flow direction. The voltage is tapped at two
More informationVENTURIMETER EXPERIMENT
ENTURIMETER EXERIMENT. OBJECTİE The main objectives of this experiment is to obtain the coefficient of discharge from experimental data by utilizing venturi meter and, also the relationship between Reynolds
More informationRapid Averaging Probe (RAP)
() The probe (Rapid Averaging Probe) is designed for fast and accurate measurements of average velocity in ductwork. The probe averages the stagnation (impact) pressure across the duct allowing for the
More informationThe Mechatronics Design for Measuring Fluid Friction Losses in Pipe Flows Rıza Gurbuz
Solid State Phenomena Vol. 113 (2006) pp 603-608 Online available since 2006/Jun/15 at www.scientific.net (2006) Trans Tech Publications, Switzerland doi:10.4028/www.scientific.net/ssp.113.603 The Mechatronics
More informationMeasurement of fluid flow in closed conduits
BRITISH STANDARD BS 1042-1.4: 1992 Incorporating Amendment No. 1 Measurement of fluid flow in closed conduits Part 1: Pressure differential devices Section 1.4 Guide to the use of devices specified in
More informationCalculation of Pipe Friction Loss
Doc.No. 6122-F3T071 rev.2 Calculation of Pipe Friction Loss Engineering Management Group Development Planning Department Standard Pump Business Division EBARA corporation October 16th, 2013 1 / 33 2 /
More informationISO 5136 INTERNATIONAL STANDARD. Acoustics Determination of sound power radiated into a duct by fans and other air-moving devices In-duct method
INTERNATIONAL STANDARD ISO 5136 Second edition 2003-04-01 Acoustics Determination of sound power radiated into a duct by fans and other air-moving devices In-duct method Acoustique Détermination de la
More informationTransCanada / Daniel Using Advances Diagnostics to Identify Measurement Uncertainties
TransCanada / Daniel Using Advances Diagnostics to Identify Measurement Uncertainties Thomas Hart, TransCanada Martin Schlebach, Emerson/Daniel April 2018 Introduction Columbia Gulf is a subsidiary of
More informationRoll No. :... Invigilator s Signature :.. CS/B.Tech (EIE)/SEM-5/EI-501/ INDUSTRIAL INSTRUMENTATION II
Name : Roll No. :.... Invigilator s Signature :.. CS/B.Tech (EIE)/SEM-5/EI-501/2011-12 2011 INDUSTRIAL INSTRUMENTATION II Time Allotted : 3 Hours Full Marks : 70 The figures in the margin indicate full
More informationISO 9906 INTERNATIONAL STANDARD. Rotodynamic pumps Hydraulic performance acceptance tests Grades 1 and 2
INTERNATIONAL STANDARD ISO 9906 First edition 1999-1-15 Rotodynamic pumps Hydraulic performance acceptance tests Grades 1 and Pompes rotodynamiques Essais de fonctionnement hydraulique pour la réception
More informationWhite Paper FINAL REPORT AN EVALUATION OF THE HYDRODYNAMICS MECHANISMS WHICH DRIVE THE PERFORMANCE OF THE WESTFALL STATIC MIXER.
White Paper FINAL REPORT AN EVALUATION OF THE HYDRODYNAMICS MECHANISMS WHICH DRIVE THE PERFORMANCE OF THE WESTFALL STATIC MIXER Prepared by: Dr. Thomas J. Gieseke NUWCDIVNPT - Code 8233 March 29, 1999
More informationME 309 Fluid Mechanics Fall 2010 Exam 2 1A. 1B.
Fall 010 Exam 1A. 1B. Fall 010 Exam 1C. Water is flowing through a 180º bend. The inner and outer radii of the bend are 0.75 and 1.5 m, respectively. The velocity profile is approximated as C/r where C
More informationNUMERICAL EVALUATION OF DISTORTED VELOCITY PROFILE EFFECTS ON INSERTION FLOW METERS
Vienna, AUSTRIA, 2, September 2-28 NUMERICAL EVALUATION OF DISTORTED VELOCITY PROFILE EFFECTS ON INSERTION FLOW METERS G. Buonanno, M. Dell'Isola, N.Massarotti Di.M.S.A.T. - Università di Cassino via Di
More informationCOURSE CODE : 3072 COURSE CATEGORY : B PERIODS/ WEEK : 5 PERIODS/ SEMESTER : 75 CREDIT : 5 TIME SCHEDULE
COURSE TITLE : FLUID MECHANICS COURSE CODE : 307 COURSE CATEGORY : B PERIODS/ WEEK : 5 PERIODS/ SEMESTER : 75 CREDIT : 5 TIME SCHEDULE MODULE TOPIC PERIOD 1 Properties of Fluids 0 Fluid Friction and Flow
More informationGRANULAR PRESSURE MEASUREMENT IN FLUIDIZED BEDS
GRANULAR PRESSURE MEASUREMENT IN FLUIDIZED BEDS S. Kumar, D. P. Hart, and C. E. Brennen California Institute of Technology Pasadena, California Abstract Experiments were carried out to measure the additional
More informationDischarge Coefficient Prediction for Multi hole Orifice Plate in a Turbulent Flow through Pipe: Experimental and Numerical Investigation
Discharge Coefficient Prediction for Multi hole Orifice Plate in a Turbulent Flow through Pipe: Experimental and Numerical Investigation [] Mahendra Babu.K.J, [2] Dr. Gangadhara Gowda C.J, [3] Ranjith
More informationFlow Measurement in Pipes and Ducts COURSE CONTENT
Flow Measurement in Pipes and Ducts Dr. Harlan H. Bengtson, P.E. COURSE CONTENT 1. Introduction This course is about measurement of the flow rate of a fluid flowing under pressure in a closed conduit.
More informationBounding the Uncertainties of the Meter Factors for LEFM CheckPlus Flow Elements in Feedwater Flow Measurements
Bounding the Uncertainties of the Meter Factors for LEFM CheckPlus Flow Elements in Feedwater Flow Measurements ABSTRACT Don Augenstein, Herb Estrada Cameron 1000 McClaren Woods Drive Coraopolis, PA 15108
More informationMODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH
MODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH No. Part Name Quantity BOM code List Price Remark 1 Panel assembly 1 201132890609 2 Air filter 2 201132890704 5 Display box
More informationEXPERIMENT No.1 FLOW MEASUREMENT BY ORIFICEMETER
EXPERIMENT No.1 FLOW MEASUREMENT BY ORIFICEMETER 1.1 AIM: To determine the co-efficient of discharge of the orifice meter 1.2 EQUIPMENTS REQUIRED: Orifice meter test rig, Stopwatch 1.3 PREPARATION 1.3.1
More informationEXPERIMENTAL INVESTIGATION OF THE INSTALLATION EFFECTS ON THE VENTURI FLOWMETER PERFORMANCE
Proceedings of the FEDSM2000 2000 ASME Fluids Engineering Conference June 11-15, 2000, Boston, USA FEDSM2000-11107 EXPERIMENTAL INVESTIGATION OF THE INSTALLATION EFFECTS ON THE VENTURI FLOWMETER PERFORMANCE
More informationAir Flow through Woven Stainless Steel Mesh
Air Flow through Woven Stainless Steel Mesh Abstract It was known that a mesh screen placed across an airflow will have an evening effect, distributing both the velocity and pressure across the screen,
More informationLab Section Date. ME4751 Air Flow Rate Measurement
Name Lab Section Date ME4751 Air Flow Rate Measurement Objective The objective of this experiment is to determine the volumetric flow rate of air flowing through a pipe using a Pitot-static tube and a
More informationVELOCITY PROFILE EFFECTS IN CORIOLIS MASS FLOWMETERS: RECENT FINDINGS AND OPEN QUESTIONS
VELOCITY PROFILE EFFECTS IN CORIOLIS MASS FLOWMETERS: RECENT FINDINGS AND OPEN QUESTIONS J. Kutin a, *, G. Bobovnik a, J. Hemp b, I. Bajsić a a Laboratory of Measurements in Process Engineering, Faculty
More informationLECTURE 6- ENERGY LOSSES IN HYDRAULIC SYSTEMS SELF EVALUATION QUESTIONS AND ANSWERS
LECTURE 6- ENERGY LOSSES IN HYDRAULIC SYSTEMS SELF EVALUATION QUESTIONS AND ANSWERS 1. What is the head loss ( in units of bars) across a 30mm wide open gate valve when oil ( SG=0.9) flow through at a
More informationFundamentals of Flow Metering
Technical Data Sheet 00816-0100-3031 Fundamentals of Flow Metering A reliable flow indication is dependent upon the correct measurement of A and V. If, for example, air bubbles are present in the fluid,
More informationFLOW MEASUREMENT IN PIPES EXPERIMENT
University of Leicester Engineering Department FLOW MEASUREMENT IN PIPES EXPERIMENT Page 1 FORMAL LABORATORY REPORT Name of the experiment: FLOW MEASUREMENT IN PIPES Author: Apollin nana chaazou Partner
More informationNEW VSL Conditioning plate!
Calibration of Prover Tanks using a Coriolis Mass Flow Meter as the Master Meter. Is this possible for Pipe Prover calibration too? Erik Smits (fsmits@vsl.nl) 2 nd European Flow Measurement Workshop Sintra,
More informationAddendum to ARI Standard , Air Terminals September 2002
Addendum to ARI Standard 880-98, Air Terminals September 2002 The September 2002 Addendum to ARI Standard 880-98, Air Terminals, is comprised of only the shaded portions shown, which has been incorporated
More informationDirect-operated 2/2-way compact solenoid valves Type EV210A
Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together
More informationP303 Pressure Regulator
P0 Pressure Regulator Minimize Sudden Downstream Load Change Wide Pressure Ranges Integral Monitoring The BelGAS P0 and P0H gas pressure reducing regulators are available with a true monitor regulator,
More informationCalibration of Orifice Flow Meter and Venturi Flow Meter
Calibration of Orifice Flow Meter and Venturi Flow Meter D. Till Abstract Orifice and venturi flow meters decrease the pressure of a fluid b increasing its velocit as it flows through them. This is done
More informationMeasurements using Bernoulli s equation
An Internet Book on Fluid Dynamics Measurements using Bernoulli s equation Many fluid measurement devices and techniques are based on Bernoulli s equation and we list them here with analysis and discussion.
More informationCORIOLIS MASS FLOW METERS FOR GAS AND LIQUID MEASUREMENT. Michael Keilty (Presented by Hubbard Donald) Endress + Hauser Flowtec AG
Introduction CORIOLIS MASS FLOW METERS FOR GAS AND LIQUID MEASUREMENT Michael Keilty (Presented by Hubbard Donald) Endress + Hauser Flowtec AG A mass flowmeter is a system that provides a measurement of
More informationCompressible Gas Flow
Compressible Gas Flow by Elizabeth Adolph Submitted to Dr. C. Grant Willson CHE53M Department of Chemical Engineering The University of Texas at Austin Fall 008 Compressible Gas Flow Abstract In this lab,
More informationNumerical and Experimental Study on the Effect of Guide Vane Insertion on the Flow Characteristics in a 90º Rectangular Elbow
Numerical and Experimental Study on the Effect of Guide Vane Insertion on the Flow Characteristics in a 90º Rectangular Elbow Sutardi 1, Wawan A. W., Nadia, N. and Puspita, K. 1 Mechanical Engineering
More informationDecay of Rotational Airflow with Flow Conditioner in Larger Diameter Ducts for Dust Concentration Measurement using Isokinetic Sampling
1 Decay of Rotational Airflow with Flow Conditioner in Larger Diameter Ducts for Dust Concentration Measurement using Isokinetic Sampling Z. C. Tan, Y. Zhang, S. E. Ford Department of Agricultural and
More informationHeat Exchangers for Condensation and Evaporation Applications Operating in a Low Pressure Atmosphere
Acta Polytechnica Vol. 52 No. 3/202 Heat Exchangers for Condensation and Evaporation Applications Operating in a Low Pressure Atmosphere Petr Kracík,JiříPospíšil, Ladislav Šnajdárek Brno University of
More information9.1 Introduction. 9.2 Fluid Flow. CHAPTER 9 Flow
CHAPTER 9 9.1 Introduction The accurate measurement of fluid flow is very important in many industrial applications. Optimum performance of many processes requires specific flow rates. The cost of many
More informationinter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE
Copyright SFA - InterNoise 2000 1 inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering 27-30 August 2000, Nice, FRANCE I-INCE Classification: 1.1 DESIGN OF TERMINATING
More informationABSTRACT I. INTRODUCTION
2016 IJSRSET Volume 2 Issue 4 Print ISSN : 2395-1990 Online ISSN : 2394-4099 Themed Section: Engineering and Technology Analysis of Compressible Effect in the Flow Metering By Orifice Plate Using Prasanna
More informationGAS MASS FLOW METERING AN ALTERNATIVE APPROACH Eric Sanford, Vortek Instruments Koichi Igarashi, Azbil North America Kim Lewis, DP Diagnostics
GAS MASS FLOW METERING AN ALTERNATIVE APPROACH Eric Sanford, Vortek Instruments Koichi Igarashi, Azbil North America Kim Lewis, DP Diagnostics INTRODUCTION Metering a fluid s mass flow rate in a pipe with
More informationFluid Flow Analysis Penn State Chemical Engineering
Fluid Flow Analysis Penn State Chemical Engineering Revised Spring 2015 Table of Contents LEARNING OBJECTIVES... 1 EXPERIMENTAL OBJECTIVES AND OVERVIEW... 1 PRE-LAB STUDY... 2 EXPERIMENTS IN THE LAB...
More informationTurbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas
Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement
More informationVD1 CLC. Small Valves DIN-range with a higher k v -value
0 EN - Small Valves DIN-range with a higher k v -value VD CLC Valve body made of brass, mat nickel-plated DN, DN 0 and DN Internally and externally threaded (Rp / R) conforming to ISO 7- Manual knob /
More informationINTERNATIONAL OIML D 25 DOCUMENT. Vortex meters used in measuring systems for fluids ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION
INTERNATIONAL OIML D 25 DOCUMENT Edition 1996 (E) Vortex meters used in measuring systems for fluids Compteurs à vortex utilisés dans les ensembles de mesurage de fluides OIML D 25 Edition 1996 (E) ORGANISATION
More informationOrifice and Venturi Pipe Flow Meters
Orifice and Venturi Pipe Flow Meters by Harlan H. Bengtson, PhD, P.E. 1. Introduction Your Course Title Here The flow rate of a fluid flowing in a pipe under pressure is measured for a variety of applications,
More informationMEDIDAS EN FLUIDOS. INEL 5205 Instrumentación. Monday, November 19, 12
MEDIDAS EN FLUIDOS INEL 5205 Instrumentación SENSORES DE PRESIÓN Unidades de Presión 1 psi! 1 lbf/in 2 = 6,894.76! Pa = 6,894.76!newton/m 2 = 68.948 10 3!bar (1 bar = 10 5 Pa) = 68.046 10 3!atm = 51.715
More informationA MULTIPATH ULTRASONIC METER WITH REDUCING NOZZLE FOR IMPROVED PERFORMANCE IN THE LAMINAR/TURBULENT TRANSITION REGION
A MULTIPATH ULTRASONIC METER WITH REDUCING NOZZLE FOR IMPROVED PERFORMANCE IN THE LAMINAR/TURBULENT TRANSITION REGION Gregor J Brown, Cameron, UK Terry Cousins, Cameron, USA Donald R Augenstein, Cameron,
More informationDifferential Pressure Producing Flow Elements
Differential Pressure Producing Flow Elements Standards Certification Education & Training Publishing Conferences & Exhibits Fort McMurray, Alberta Differential Pressure Devices for Liquid and Gas Flow
More informationEXPERIMENT NO. 4 CALIBRATION OF AN ORIFICE PLATE FLOWMETER MECHANICAL ENGINEERING DEPARTMENT KING SAUD UNIVERSITY RIYADH
EXPERIMENT NO. 4 CALIBRATION OF AN ORIFICE PLATE FLOWMETER MECHANICAL ENGINEERING DEPARTMENT KING SAUD UNIVERSITY RIYADH Submitted By: ABDULLAH IBN ABDULRAHMAN ID: 13456789 GROUP A EXPERIMENT PERFORMED
More informationPhysics 3 Summer 1990 Lab 7 - Hydrodynamics
Physics 3 Summer 1990 Lab 7 - Hydrodynamics Theory Consider an ideal liquid, one which is incompressible and which has no internal friction, flowing through pipe of varying cross section as shown in figure
More informationFlow Measurement in Pipes and Ducts
Flow Measurement in Pipes and Ducts Course No: M04-040 Credit: 4 PDH Harlan H. Bengtson, Ph.D., P.E. Continuing Education and Development, Inc. 9 Greyridge Farm Court Stony Point, NY 10980 P: (877) 322-5800
More informationCALIBRATION CERTIFICATE # 503
CALIBRATION CERTIFICATE # 503 Calibration date : 2011-02-23 Certificate issued : 2012-04-18 Company name Company address City, Province, Canada CLAS 2009-02 Calibration of Mass flow meter Micro Motion
More informationMechanical Measurements and Metrology Prof. S. P. Venkateshan Department of Mechanical Engineering Indian Institute of Technology, Madras
Mechanical Measurements and Metrology Prof. S. P. Venkateshan Department of Mechanical Engineering Indian Institute of Technology, Madras Module - 3 Lecture - 33 Measurement of Volume and Mass Flow Rate
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 TRI-STATE INSTRUMENT SERVICE, INC. 3024 Wayne Trace Ft. Wayne, IN 46806 Lynn A. Stroble Phone: 260 456 4545 CALIBRATION Valid To: September
More informationDESIGN AND CONSTRUCTION OF A WATER TUNNEL. Stephen C. Ko
i DESGN AND CONSTRUCTON OF A WATER TUNNEL By Stephen C. Ko This work has been carried out as a part of a grant from the National Science Foundation for the development of fluid mechanics laboratory equipments
More information"Experimental investigation of heat transfer enhancement by u-shaped Turbulator"
"Experimental investigation of heat transfer enhancement by u-shaped Turbulator" Pawar Shubham (1),Pailwan Vidyadhar (2), Kothawale Shridhar (3), Vaibhav Sonavane (4),Akshay Londhe (5) 1,2,3,4UG Scholar,
More information