FL ballasts Electronic dimming. PCA TC ECO Y II, W ECO compact

Size: px
Start display at page:

Download "FL ballasts Electronic dimming. PCA TC ECO Y II, W ECO compact"

Transcription

1 FL ballasts EL TC-F TC-SEL TC-L HE TC-DD Tc PCA TC ECO Y II, 7 W ECO compact Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A BAT Noise-free precise control via DALI or DSI signal, switchdim or corridorfunction Nominal life up to 00,000 h (at ta 0 C with a failure rate max. 0. % per,000 h) OEM-specific reserved memory areas -year guarantee Interfaces 99 DALI ±0, DSI switchdim (with memory function + selectable dimming rate) corridorfunction ( preprogrammed profiles) Integrated SMART interface for function with,, 79±0, SMART Sensor D 9f and corridorfunction plugs Functions Intelligent Temperature Guard (overtemperature protection) 4, 0, ±0, Intelligent Voltage Guard (overvoltage indication and undervoltage shutdown) 99 ±0, Optimum filament heating in any dimmer setting Disconnection of filament heating from a dimming level of approx. 90 % for maximum energy efficiency (SMART-Heating concept) corridorfunction with ambient light control 89, 0±0, Automatically triggered emergency lighting value in DC mode, % For emergency lighting systems as per EN 07, Automatic start after replacement of defective lamps Automatic shutdown if the lamp is faulty 4, È Standards, page Wiring diagrams and installation examples, page 8 0, ±0, Technical data Mains voltage range 0 40 V AC voltage range 98 4 V DC voltage range 7 80 V (lamp start 98 V DC) Mains frequency 0 / 0 / 0 Hz Overvoltage protection 0 V AC, h Typ. power input on standby < 0. W Protective hot restart 0. s for AC / 0. s for DC Dimming range 00 % Lamp start possible from % Operating frequency ~ 40 0 khz Type of protection IP0

2 Specific technical data Lamp wattage Lamp type Type For luminaires with lamp Article number Ordering data Dimensions L x W x H Lamp power Circuit power EEI Current at 0 Hz 0 V λ at 0 Hz 0 V tc point max. Ambient temperature ta x W TC-SEL PCA x/ TC ECO Y II 8 x 79 x mm.0 W. W A 0.0 A C C x W HE PCA x/ TC ECO Y II 8 x 79 x mm. W.0 W A 0.07 A C C x W PCA x/ TC ECO Y II 8 x 79 x mm. W. W A BAT 0.07 A C C x W PCA x/ TC ECO Y II 8 x 79 x mm. W 4.0 W A BAT 0.07 A C C x 4 W HE PCA x/ TC ECO Y II 8 x 79 x mm 4. W.0 W A BAT 0.08 A C C x 7 W HE PCA x/ TC ECO Y II 8 x 79 x mm 7. W 9.0 W A BAT 0.09 A C C x 8 W PCA x8 TC ECO Y II 8 x 79 x mm. W 9.0 W A BAT 0.09 A C C x 8 W PCA x8 TC ECO Y II 8 x 79 x mm. W 8. W A BAT 0.09 A C C x 8 W TC-F PCA x8/4 TCL ECO c Y II 8 x 79 x mm.0 W 8. W A BAT 0.08 A C -... C x 8 W TC-L PCA x8/4 TCL ECO c Y II 8 x 79 x mm.0 W 8. W A BAT 0.08 A C -... C x W Tc PCA x8/4 TCL ECO c Y II 8 x 79 x mm.0 W.0 W A BAT 0. A C -... C x 4 W TC-F PCA x8/4 TCL ECO c Y II 8 x 79 x mm 0.0 W 4. W A BAT 0. A C -... C x 4 W TC-L PCA x8/4 TCL ECO c Y II 8 x 79 x mm.0 W 4. W A BAT 0. A C -... C x W PCA x-7 TC ECO Y II 80 x 79 x mm 4.0 W. W A BAT 0. A C -... C x W PCA x-7 TC ECO Y II 80 x 79 x mm 4.0 W 7.0 W A BAT 0. A C -... C x W PCA x-7 TC ECO Y II 80 x 79 x mm.0 W.0 W A BAT 0. A C -... C x 40 W Tc PCA x-7 TC ECO Y II 80 x 79 x mm 40.0 W 4.0 W A BAT 0. A C -... C x 40 W TC-L PCA x-7 TC ECO Y II 80 x 79 x mm 40.0 W 4.0 W A BAT 0.8 A C -... C x 4 W PCA x-7 TC ECO Y II 80 x 79 x mm 4.0 W 44.0 W A BAT 0.0 A C -... C x 7 W PCA x-7 TC ECO Y II 80 x 79 x mm 7.0 W.0 W A BAT 0.4 A C -... C x 8 W TC-DD PCA x8 TC-DD ECO Y II 8 x 79 x mm. W 7. W A BAT 0. A C -... C x W Tc PCA x Tc ECO Y II 84 x 79 x mm.0 W 9.0 W A BAT 0. A C -... C For luminaires with lamps x W TC-SEL PCA x/ TC ECO Y II 87 x 0 x mm.0 W 4. W A BAT 0. A C C x W HE PCA x/ TC ECO Y II 87 x 0 x mm. W.0 W A BAT 0. A C C x W PCA x/ TC ECO Y II 87 x 0 x mm.0 W 7.0 W A BAT 0. A C C x W PCA x/ TC ECO Y II 87 x 0 x mm.0 W 7. W A BAT 0. A C C x 4 W HE PCA x/ TC ECO Y II 87 x 0 x mm 9.0 W.0 W A BAT 0. A C C x 7 W HE PCA x/ TC ECO Y II 87 x 0 x mm.0 W 7. W A BAT 0.7 A C C x 8 W PCA x8 TC ECO Y II 8 x 0 x mm.0 W.0 W A BAT 0.7 A C C x 8 W PCA x8 TC ECO Y II 8 x 0 x mm.0 W.0 W A BAT 0.7 A C C x 8 W TC-F PCA x8/4 TCL ECO c Y II 88 x 0 x mm.0 W 7.0 W A BAT 0. A C C x 8 W TC-L PCA x8/4 TCL ECO c Y II 88 x 0 x mm.0 W 7.0 W A BAT 0. A C C x 4 W TC-F PCA x8/4 TCL ECO c Y II 88 x 0 x mm 0.0 W 48.0 W A BAT 0. A C C x 4 W TC-L PCA x8/4 TCL ECO c Y II 88 x 0 x mm.0 W 48.0 W A BAT 0. A C C x W PCA x//4 TC ECO Y II 8 x 0 x mm 48.0 W.0 W A BAT 0.4 A C C x W PCA x//4 TC ECO Y II 8 x 0 x mm 48.0 W.0 W A BAT 0.4 A C C x W PCA x//4 TC ECO Y II 8 x 0 x mm 4.0 W 8.0 W A BAT 0.9 A C C x 4 W PCA x//4 TC ECO Y II 8 x 0 x mm 84.0 W 88. W A BAT 0.9 A C C According to the EU directives on ecodesign requirements (EC) No. 4/009 and (EC) No. 47/00. Valid at 00 % dimming level. +0 C to ta max: unrestricted dimming. - C to +0 C: unrestricted dimming from 00 % to 0 %. - C to +0 C, dimming below 0 %: malfunction possible but no damage to ECG. This applies to AC and DC operation. Type For luminaires with lamp Article number Packaging, carton Packaging, pallet Weight per pc. PCA x/ TC ECO Y II 8 0 pc(s). 00 pc(s). 0.4 kg PCA x8 TC ECO Y II 8 0 pc(s). 00 pc(s) kg PCA x8/4 TCL ECO c Y II 8 0 pc(s). 00 pc(s) kg PCA x-7 TC ECO Y II 80 0 pc(s). 00 pc(s). 0. kg PCA x8 TC-DD ECO Y II 8 0 pc(s). 00 pc(s) kg PCA x Tc ECO Y II 84 0 pc(s). 00 pc(s). 0. kg For luminaires with lamps PCA x/ TC ECO Y II 87 0 pc(s). 00 pc(s). 0.0 kg PCA x8 TC ECO Y II 8 0 pc(s). 00 pc(s). 0.0 kg PCA x8/4 TCL ECO c Y II 88 0 pc(s). 00 pc(s). 0.0 kg PCA x//4 TC ECO Y II 8 0 pc(s). 00 pc(s). 0.0 kg

3 Standards EN 0 EN 099 EN EN 47-- EN 47 Suitable for emergency installations according to EN 07 CISPR CISPR IEC 099 IEC IEC 47-- IEC 47 IEC 8 (according to DALi standard V) Lamp starting characteristics Warm start Starting time 0. s with AC Starting time 0. s with DC Start at any dimming level AC operation Mains voltage 0 40 V 0/0 Hz 98 4 V 0/0 Hz including safety tolerance (±0 %) 98 4 V 0/0 Hz including performance tolerance (+ % / -8 %) DC operation 0 40 V 0 Hz 98 4 V 0 Hz certain lamp start 7 80 V 0 Hz operating range Use in emergency lighting installations according to EN 07 or for emergency luminaires according to EN 47-- appendix J. Light output level in DC operation Default value is %. EBLF = 0. x adjusted DC dimming level (e.g. 0. x 0.7). Mains currents in DC operation (at % light output) Type Lamp type Wattage Mains current at Un = 0 VDC Mains current at Un = 7 VDC TC-SEL x W 0.04 A 0.0 A HE x W 0.04 A 0.0 A PCA x/ TC ECO Y II x W 0.04 A 0.0 A x W 0.04 A 0.0 A HE x 4 W 0.04 A 0.04 A HE x 7 W 0.04 A 0.04 A PCA x8 TC ECO Y II x 8 W 0.0 A 0.04 A x 8 W 0.04 A 0.04 A TC-F x 8 W 0.04 A 0.04 A TC-L x 8 W 0.04 A 0.04 A PCA x8/4 TCL ECO c Y II Tc x W 0.0 A 0.0 A TC-F x 4 W 0.0 A 0.04 A TC-L x 4 W 0.0 A 0.0 A x W 0.0 A 0.0 A x W 0.0 A 0.0 A x W 0.0 A 0.0 A PCA x-7 TC ECO Y II Tc x 40 W 0.07 A 0.0 A TC-L x 40 W 0.07 A 0.07 A x 4 W 0.07 A 0.07 A x 7 W 0.09 A 0.08 A PCA x8 TC-DD ECO Y II TC-DD x 8 W 0.0 A 0.0 A PCA x Tc ECO Y II Tc x W 0.0 A 0.09 A TC-SEL x W 0.0 A 0.0 A HE x W 0.0 A 0.0 A PCA x/ TC ECO Y II x W 0.0 A 0.0 A x W 0.0 A 0.0 A HE x 4 W 0.0 A 0.0 A HE x 7 W 0.07 A 0.0 A PCA x8 TC ECO Y II x 8 W 0.07 A 0.07 A x 8 W 0.07 A 0.0 A TC-F x 8 W 0.07 A 0.0 A PCA x8/4 TCL ECO c Y II TC-L x 8 W 0.07 A 0.0 A TC-F x 4 W 0.09 A 0.07 A TC-L x 4 W 0.04 A 0.07 A x W 0. A 0.09 A PCA x//4 TC ECO Y II x W 0.0 A 0.09 A x W 0. A 0.0 A x 4 W 0. A 0. A Emergency units The PCA TC ECO y II ballasts are compatible with all emergency units from Tridonic. See the table in the data sheet. Also all -pole emergency units can be used. When used with other emergency units tests are necessary. Temperature range Unlimited dimming range from 0 C bis ta max. - C bis 0 C: unlimited dimming from 00 % to 0 %. - C bis 0 C, dimming below 0 %: malfunction possible, but no electronic ballast damage. This applies to AC and DC operation.

4 Ballast lumen factor AC operation (AC-BLF) EN Type Lamp type Wattage AC-BLF at U = 0 VAC TC-SEL x W.04 HE x W.0 PCA x/ TC ECO Y II x W.00 x W 0.99 HE x 4 W.0 HE x 7 W.0 PCA x8 TC ECO Y II x 8 W.0 x 8 W.0 TC-F x 8 W 0.97 TC-L x 8 W 0.97 PCA x8/4 TCL ECO c Y II Tc x W.0 TC-F x 4 W.0 TC-L x 4 W.0 x W.00 x W.0 x W 0.98 PCA x-7 TC ECO Y II Tc x 40 W 0.9 TC-L x 40 W 0.9 x 4 W.00 x 7 W 0.98 PCA x8 TC-DD ECO Y II TC-DD x 8 W.0 PCA x Tc ECO Y II Tc x W.00 TC-SEL x W.04 HE x W.04 PCA x/ TC ECO Y II x W 0.99 x W 0.98 HE x 4 W.04 HE x 7 W.04 PCA x8 TC ECO Y II x 8 W.0 x 8 W.0 TC-F x 8 W 0.94 PCA x8/4 TCL ECO c Y II TC-L x 8 W 0.94 TC-F x 4 W.0 TC-L x 4 W.0 x W.00 PCA x//4 TC ECO Y II x W.0 x W 0.97 x 4 W 0.99 The ballast lumen factor for AC operation (AC-BLF) does not alter from Un = 98 V AC to Un = 4 V AC. The ballast lumen factor for DC operation (DC-BLF) on the basis of an automatic power reduction of the ballasts (default value is %) will be smaller than AC. It does not alter in the DC operating range (98 4 V DC). 4

5 Dimming Dimming curve is adapted to the eye sensitiveness. Dimming range % to 00 % Digital control with: DSI signal: 8 bit Manchester Code Speed % to 00 % in, s DALI signal: bit Manchester Code Maximum speed % to 00 % in 0 ms (adjustable between 00 ms and 90 s) Programmable parameter: Minimum dimming level Maximum dimming level Default minimum = % Default maximum = 00 % Control input (DA/D, DA/D) Digital DSI signal, push-to-make switch (switchdim) or the digital control signal DALI/DSI can be wired on the same terminals (DA/D and DA/D). Dimming characteristics PCA TC ECO Y II digital dimming value 00 DALI 7 DSI relative lighting level in % Dimming characteristics as seen by the human eye Energy saving PCA TC ECO Y II mains power in % dimming level in % Digital signal DALI/DSI The control input is non-polar and protected against accidental connection with a mains voltage up to 4 V. The control signal is not SELV. Control cable has to be installed in accordance to the requirements of low voltage installations. Different functions depending on each module. SMART interface An additional interface for the direct connection of the SMART-Sensor D 9f ) or corridorfunction plugs. Application and functionallity see corridorfunction user manual. SMART-Sensor D 9f ) light sensor operating mode: The sensor registers actual ambient light and maintains the individually defined constant lux level. After every mains reset the SMART interface automatically checks for an installed sensor. With the sensor installed the PCA TC ECO y II automatically runs in the constant lux level mode. ON/OFF switch via mains, switchdim or DSI signal. DSI signal = 0 switches off, DSI signal switches on. With switchdim signals it is possible to change the controlled light level temporarily. Temporarily means that after a switching cycle OFF/ ON command the ballast will start at the preset value determined by the SAMRT-Sensor D 9f. The installation of the two wire bus is according to the appropriate low voltage regulations. ) Light sensor D: article number 8499 switchdim Integrated switchdim function allows a direct connection of a push to make switch for dimming and switching. Brief push (< 0. s) switches ballast ON and OFF. The ballasts switch-on at light level set at switch-off. After switch ON the last settet dimming level will be activated again. When the push to make switch is held, PCA ballasts are dimmed. After repush the PCA is dimmed in the opposite direction. The switchdim fade time is set to s from min. to max. in the factory settings. With a 0 s push to the push to make switch this fade time can be changed to s. In this instance the switchdim application will be synchronized to 0 % light level after 0 s and after 0 s the light level rises to 00 % with the new fade time. At every synchronizsation (0 s keystroke) the device will reset to s (factory setting) In installations with PCAs with different dimming levels or opposite dimming directions (e.g. after a system extension), all PCAs can be synchronized to 0 % dimming level by a 0 s push. Use of push to make switch with indicator lamp is not permitted. switchdim and corridorfunction are very simple tools for controlling ballasts with conventional momentaryaction switches or motion sensors. To ensure correct operation a sinusoidal mains voltage with a frequency of 0 Hz or 0 Hz is required at the control input. Special attention must be paid to achieving clear zero crossings. Serious mains faults may impair the operation of switchdim and corridorfunction. corridorfunction To activate the corridorfunction a voltage of 0 V simply has to be applied for five minutes at switchdim connection. The unit will then switch automatically to the corridorfunction. Note: If the corridorfunction is wrongly activated in a switchdim system (for example a switch is used instead of pushbutton), there is the option of installing a pushbutton and deactivating the corridorfunction mode by five short pushes of the button within three seconds. The corridorfunction offers the added benefit of a second and third preprogrammed profile, which can be activated by the corridorfunction plugs. It is also possible to combine the corridorfunction with the SMART-Sensor D 9f light sensor. Application and functionallity of profiles see user manual of the corridorfunction. switchdim PCA TC ECO Y II DSI PCA TC ECO Y II DALI PCA TC ECO Y II D D D D D D DA DA corridorfunction PCA TC ECO Y II N L N L DSI DALI

6 Loading of automatic circuit breakers (Limitation via inrush current) Automatic circuit breaker type C0 C C C0 B0 B B B0 Inrush current (. mm ) Inrush current (. mm ) Installation Ø. mm. mm. mm. mm. mm. mm. mm. mm I max time I max time PCA x/ TC ECO Y II A µs. A 7 µs PCA x8 TC ECO Y II A 47 µs 4. A 0 µs PCA x8/4 TCL ECO c Y II A 0 µs. A 99 µs PCA x-7 TC ECO Y II A µs 0.4 A µs PCA x8 TC-DD ECO Y II A 89 µs 8.8 A 7 µs PCA x Tc ECO Y II A 40 µs 7. A µs PCA x/ TC ECO Y II A 89 µs.7 A 8 µs PCA x8 TC ECO Y II A 8 µs 9.7 A 4 µs PCA x8/4 TCL ECO c Y II A µs 7. A 4 µs PCA x//4 TC ECO Y II A 48 µs.4 A 4 µs Continuous operation: to calculate the protective saftey switch see main current, page Intelligent Voltage Guard Intelligent Voltage Guard is the name of the electronic monitor from Tridonic. This inno vative feature of the PCA family of control gear from Tridonic immediately shows if the mains voltage rises above certain thresholds. Measures can then be taken quickly to prevent damage to the control gear. If the mains voltage rises above approx. 8 Vrms (voltage depends on the ballast type), the lamp starts flashing on and off. To avoid a damage of the device the mains supply has to be switched off at this signal. Intelligent Temperature Guard The intelligent temperature guard protects the PCA TC ECO y II from thermal overheating by reducing the output power or switching off in case of operation above the thermal limits of the luminaire or ballast. Depending on the luminaire design, the ITG operates at about to 0 C above tc temperature. Harmonic distortion in the mains supply (at 0 V / 0 Hz) Type Lamp type Wattage THD 7 9 TC-SEL x W 0 4 HE x W 0 4 PCA x/ TC ECO Y II x W 0 4 x W 0 4 HE x4 W 9 HE x7 W 8 PCA x8 TC ECO Y II x8 W 9 7 x8 W 9 7 TC-F x8 W 0 4 TC-L x8 W 9 4 PCA x8/4 TCL ECO c Y II Tc x W 8 4 TC-F x4 W 8 4 TC-L x4 W 7 4 x W 0 x W 0 x W 9 PCA x-7 TC ECO Y II Tc x40 W 9 TC-L x40 W 9 x4 W 7 x7 W 7 PCA x8 TC-DD ECO Y II TC-DD x8 W 9 PCA x Tc ECO Y II Tc x W 8 4 TC-SEL x W HE x W PCA x/ TC ECO Y II x W x W HE x4 W 8 4 HE x7 W 8 PCA x8 TC ECO Y II x8 W 9 x8 W 9 TC-F x8 W 9 PCA x8/4 TCL ECO c Y II TC-L x8 W 9 TC-F x4 W 7 TC-L x4 W 7 x W 0 PCA x//4 TC ECO Y II x W 0 7 x W 9 7 x4 W 8 7

7 Operating voltage Type Lamp type Wattage Uout TC-SEL x W 40 V HE x W 40 V PCA x/ TC ECO Y II x W 40 V x W 40 V HE x4 W 40 V HE x7 W 40 V PCA x8 TC ECO Y II x8 W 40 V x8 W 40 V TC-F x8 W 40 V TC-L x8 W 40 V PCA x8/4 TCL ECO c Y II Tc x W 40 V TC-F x4 W 40 V TC-L x4 W 40 V x W 40 V x W 40 V x W 40 V PCA x-7 TC ECO Y II Tc x40 W 40 V TC-L x40 W 40 V x4 W 40 V x7 W 40 V PCA x8 TC-DD ECO Y II TC-DD x8 W 40 V PCA x Tc ECO Y II Tc x W 40 V TC-SEL x W 40 V HE x W 40 V PCA x/ TC ECO Y II x W 40 V x W 40 V HE x4 W 40 V HE x7 W 40 V PCA x8 TC ECO Y II x8 W 40 V x8 W 40 V TC-F x8 W 40 V PCA x8/4 TCL ECO c Y II TC-L x8 W 40 V TC-F x4 W 40 V TC-L x4 W 40 V x W 40 V PCA x//4 TC ECO Y II x W 40 V x W 40 V x4 W 40 V 7

8 Humidity: % up to max. 8 %, not condensed (max. days/year at 8 %) Storage temperature: -40 C up to max. +80 C The devices have to be within the specified temperature range (ta) before they can be operated. Installation instructions Wiring type and cross section The wiring can be in stranded wires with ferrules or solid with a cross section of 0.. mm². Strip 9. mm of insulation from the cables to ensure perfect operation of the push-wire terminals. Release of the wiring Press down the push button and remove the cable from front. wire preparation: 0.. mm² mm Mounting of device Max. torque for fixing: 0. Nm/M4 Expected life-time Type Lamp type Wattage ta = 40 C ta = 0 C ta = 0 C PCA x/ TC ECO Y II PCA x8 TC ECO Y II PCA x8/4 TCL ECO c Y II TC-SEL HE HE HE TC-F TC-L Tc TC-F TC-L x W x W x W x W x 4 W x 7 W x 8 W x 8 W x 8 W x 8 W x W x 4 W x 4 W tc 4 C C C tc 4 C C C tc 4 C C C tc 4 C C C tc 4 C C C tc 4 C C C 8

9 Expected life-time Type Lamp type Wattage ta = 40 C ta = 0 C ta = 0 C PCA x-7 TC ECO Y II Tc TC-L x W x W x W x 40 W x 40 W x 4 W x 7 W PCA x8 TC-DD ECO Y II TC-DD x 8 W PCA x Tc ECO Y II Tc x W PCA x/ TC ECO Y II PCA x8 TC ECO Y II PCA x8/4 TCL ECO c Y II PCA x//4 TC ECO Y II x = not permitted TC-SEL HE HE HE TC-F TC-L TC-F TC-L x W x W x W x W x 4 W x 7 W x 8 W x 8 W x 8 W x 8 W x 4 W x 4 W x W x W x W x 4 W tc C C 7 C Life-time > 00,000 h > 00,000 h 80,000 h tc C C 7 C Life-time > 00,000 h > 00,000 h 80,000 h tc C C 7 C Life-time > 00,000 h > 00,000 h 80,000 h tc 0 C 0 C 7 C Life-time > 00,000 h > 00,000 h 7,000 h tc 0 C 0 C 7 C Life-time > 00,000 h > 00,000 h 7,000 h tc 0 C 0 C 7 C Life-time > 00,000 h > 00,000 h 7,000 h tc C C x Life-time > 00,000 h > 00,000 h x tc C 0 C 70 C tc C 0 C 70 C tc 0 C C 7 C tc 0 C C 7 C tc 0 C C 7 C tc 0 C C 7 C tc 0 C 70 C 7 tc 0 C 70 C 7 tc 0 C 70 C 7 C tc 0 C C 7 C 9

10 Wiring advice The lead length is dependent on the capacitance of the cable. Ballast Terminal Maximum capacitance allowed Type Cold Hot Cold Hot PCA xx TC ECO Y II, 0, 00 pf 00 pf PCA xx TC ECO Y II,, 4, 0,,, 7 00 pf 00 pf With standard solid wire 0./0.7 mm² the capacitance of the lead is 0 80 pf/m. This value is influenced by the way the wiring is made. Lamp connection should be made with symmetrical wiring. Hot leads (0,,, 7) and cold leads (,, 4, ) should be separated as much as possible. When using two or more dimmable ballasts in one luminaire with separate dimming controls, the lamp leads must be kept separate. Sensor wires Sensor wires must be routed separately from the lamp wires and mains cables otherwise the lighting control system may malfunction. If separate routing is not possible (for reasons of space) shielded lamp wires and mains cables must be used. Dimmable ballasts from Tridonic have to be earthed. D/DA D/DA * * control signal D/DA D/DA * * control signal * leads 0, : keep wires short, max..0 m leads, max..0 m; ballast must be earthed * * digital signal DALI, DSI or switchdim * leads 0,,, 7 keep wires short, max..0 m leads,, 4, max..0 m; EVG erden * * digital signal DALI, DSI or switchdim PCA TC ECO Y II x8 7 W PCA TC ECO Y II x8 4 W Dimmable ballasts from Tridonic have to be earthed. RFI Connection to the lamps of the hot leads must be kept as short as possible Mains leads should be kept apart from lamp leads (ideally 0 cm distance) Do not run mains leads adjacent to the electronic ballast Twist the lamp leads Keep the distance of lamp leads from the metal work as large as possible Mains wiring to be twisted when through wiring Keep the mains leads inside the luminaire as short as possible General advise Electronic ballasts are virtually noise free. Magnetic fields generated during the ignition cycle can cause some background noise but only for a few milliseconds. Operation on DC voltage Our ballasts are construed to operate DC voltage and pulsed DC voltage. To operate ballasts with pulsed DC voltage the polarity is absolute mandatory. + DA/D DA/D Isolation and electric strength testing of luminaires Electronic devices can be damaged by high voltage. This has to be considered during the routine testing of the luminaires in production. According to IEC 098- Annex Q (informative only!) or ENEC 0-Annex A, each luminaire should be submitted to an isolation test with 00 VDC for second. This test voltage should be connected between the interconnected phase and neutral terminals and the earth terminal. The isolation resistance must be at least MΩ. As an alternative, IEC 098- Annex Q describes a test of the electrical strength with 00 VAC (or.44 x 00 VDC). To avoid damage to the electronic devices this test must not be conducted. Glow-wire test according to EN C, 70 C and 80 C passed For further technical information please visit 0

PHASED OUT. FL ballasts Electronic dimming. PCA TC BASIC Y II, W BASIC compact

PHASED OUT. FL ballasts Electronic dimming. PCA TC BASIC Y II, W BASIC compact EL Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A BAT Noise-free precise control via DSI signal, switchdim or corridorfunction Nominal life

More information

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, W EXCEL T5

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, W EXCEL T5 F ballasts E PCA EXCE oneall lp Y II, 1 80 W EXCE Product description Processor-controlled ballast with y II inside Highest possible energy class CEMA EEI = A1 BAT 1 oise-free precise control via I or

More information

FL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact

FL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact FL ballasts EL HE PC TC PRO sr 1/2x11 42 W PC PRO compact Product description CELMA Energy Efficiency Index A2 BAT / A2 T Nominal life-time up to 50,000 h (at ta 50 C with a failure rate max. 0.2 % per

More information

Emergency lighting units EM Inverter

Emergency lighting units EM Inverter T T TC- TC-F DE TC- TC-SE TC-TE TC-DD Tc EM G, 0 0 V 0/0 Hz BASIC version Product description Emergency lighting supply unit for manual testing For linear and compact fluorescent lamps ow-profile casing

More information

LED light engine / OLED LED compact. Uengine DLE G2 integrated ADV

LED light engine / OLED LED compact. Uengine DLE G2 integrated ADV Uengine DLE G2 integrated ADV uengine DLE Product description Module with integrated electronics For downlights Light engine operating with 23 V AC Luminous flux range from 1,24 2,43 lm High system efficacy

More information

LED light engine / OLED LED compact. Uready2apply DLA G1 SNC China domestic

LED light engine / OLED LED compact. Uready2apply DLA G1 SNC China domestic Uready2apply DLA G1 SNC China domestic uready2apply DLA Product description Downlight module suitable for direct installation in ceilings (ready2apply) Module with integrated electronics and heatsink Light

More information

QTi DALI-T/E 2X18 42/ DIM

QTi DALI-T/E 2X18 42/ DIM QTi DALI-T/E 2X18 42/220 240 DIM QUICKTRONIC INTELLIGENT DALI DIM CFL ECG dimmable DALI for CFL Suitable for emergency light installations Product benefits Easy change of defect ECG thanks to available

More information

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC EM STARK CLE STARK-CLE EM STARK-CLE EM-SO Ø315

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC EM STARK CLE STARK-CLE EM STARK-CLE EM-SO Ø315 D Product description Ideal for ceiling-mounted and wallmounted luminaires Based on annular and compact fluorescent lamps Efficiency of the module up to 127 lm/w SO version is compatible with SWITCH Sensor

More information

LEDlight 30 W Universal dimmable series

LEDlight 30 W Universal dimmable series LEDlight 30 W Universal dimmable series L05031 Lumotech technology Lumotech LED drivers are designed to efficiently power and control LED solutions for general lighting applications. System reliability

More information

LEDlight 20 W Universal dimmable series

LEDlight 20 W Universal dimmable series LEDlight 20 W Universal dimmable series L05011i2 / L05011i3 / L05011i4 Lumotech technology Lumotech LED drivers are designed to efficiently power and control LED solutions for general lighting applications.

More information

für for T5-Lampen fluorescent in Multi-Lamp-Technologie

für for T5-Lampen fluorescent in Multi-Lamp-Technologie Dimmbare Dimmable electronic elektronische control Vorschaltgeräte gear für for T-ampen fluorescent in Multi-amp-Technologie lamps in technology M-tec Performance characteristics Dimmable ECG in Multi-amp

More information

LED light engines LED linear / area. Module STARK QLE G3 SELECT Modules QLE EXCITE

LED light engines LED linear / area. Module STARK QLE G3 SELECT Modules QLE EXCITE Module STARK QLE G3 SELECT Modules QLE EXCITE Product description Ideal for linear and panel lights Luminous flux range from 1,9 1,62 lm LED system solution with outstanding system efficacy up to 137 lm/w,

More information

PHASED OUT. LED light engine / OLED LED compact. Module DLE G3 ADV Modules DLE

PHASED OUT. LED light engine / OLED LED compact. Module DLE G3 ADV Modules DLE w LED light engine / OLED Product description For downlights Luminous flux up to 3,68 lm at tp = 65 C High efficacy up to 165 lm/w for the LED module at tp = 25 C High system efficacy up to 147 lm/w at

More information

LED light engine / OLED LED compact. Module DLE G3 ADV Modules DLE

LED light engine / OLED LED compact. Module DLE G3 ADV Modules DLE w LED light engine / OLED Module DLE G3 ADV Modules DLE Product description For downlights Luminous flux up to 3,68 lm at tp = 65 C High efficacy up to 165 lm/w for the LED module at tp = 25 C High system

More information

Tunable White LED compact

Tunable White LED compact Module TW DLE G2 60mm 3000lm 927-965 DLE modules Product description module for Downlights with adjustable colour temperature from 2,700 to 6,500 K at constant luminous flux High colour rendering index

More information

PHASED OUT. LED light engine / OLED LED linear / area. Umodule STARK QLE G2 CLASSIC STARK QLE

PHASED OUT. LED light engine / OLED LED linear / area. Umodule STARK QLE G2 CLASSIC STARK QLE Product description Ideal for linear and panel lights Luminous flux range from 1,19 1,53 lm LED system solution with outstanding system efficiency up to 125 lm/w, consisting of squared LED modules and

More information

PHASED OUT. LED light engines LED linear / area. Module QLE G1 471x462mm 5000lm SNC Modules QLE ESSENCE

PHASED OUT. LED light engines LED linear / area. Module QLE G1 471x462mm 5000lm SNC Modules QLE ESSENCE Product description Luminous flux: 5, lm per module Square module one module per luminaire nonselv (HV) and SELV (LV) variants High colour rendering index CRI 8 Small colour tolerance (MacAdam 4) Efficacy

More information

LED light engines LED compact. Module DLE G4 ADV Modules DLE

LED light engines LED compact. Module DLE G4 ADV Modules DLE w LED light engines Module DLE G4 ADV Modules DLE Product description For downlights Luminous flux up to 6,35 lm at tp = 65 C High efficacy up to 185 lm/w for the LED module at tp = 25 C High system efficacy

More information

LED light engines LED linear / area. Module QLE G3+ ADV Modules QLE ADVANCED

LED light engines LED linear / area. Module QLE G3+ ADV Modules QLE ADVANCED Module QLE G3 ADV Modules QLE ADVANCED Product description Ideal for linear and panel lights Luminous flux range from 1, 5,25 lm LED system solution with outstanding system efficacy up to 162 lm/w, consisting

More information

PHASED OUT. LED light engines LED linear / area. Module CLE Quadrant G2 ADV Modules CLE ADVANCED

PHASED OUT. LED light engines LED linear / area. Module CLE Quadrant G2 ADV Modules CLE ADVANCED Product description Ideal for round shaped and flat ceiling and pendant luminaires THE solution to realise XXL luminaires For uniform illumination of prestige areas or rooms designed to impress High Output

More information

LED light engines LED linear / area. Module CLE Quadrant G3 ADV Modules CLE ADVANCED

LED light engines LED linear / area. Module CLE Quadrant G3 ADV Modules CLE ADVANCED Module CLE Quadrant G3 ADV Modules CLE ADVANCED Product description Ideal for round shaped and flat ceiling and pendant luminaires THE solution to realise XXL luminaires For uniform illumination of prestige

More information

LED light engine / OLED LED compact. Module DLE G4 ADV Modules DLE

LED light engine / OLED LED compact. Module DLE G4 ADV Modules DLE w LED light engine / OLED Module DLE G4 ADV Modules DLE Product description For downlights Luminous flux up to 3,71 lm at tp = 65 C High efficacy up to 185 lm/w for the LED module at tp = 25 C High system

More information

LED light engines LED linear / area

LED light engines LED linear / area Module LLE G2 55mm 4lm ADV Modules LLE ADVANCED Product description Ideal for linear and panel lights LED system solution with outstanding system efficiency up to 165 lm/w, consisting of linear LED modules

More information

LED light engines LED linear / area. Module RLE 2x6 EXC2 OTD Modules RLE EXCITE

LED light engines LED linear / area. Module RLE 2x6 EXC2 OTD Modules RLE EXCITE Module RLE 2x6 EXC2 OTD Modules RLE EXCITE Product description High efficiency outdoor modules Suitable for harsh and humid outdoor conditions Tested acc. to salt spray test (IEC 668-2-52) and harmful

More information

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 15mm 2000lm 8x0 H ADV D50

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 15mm 2000lm 8x0 H ADV D50 w LED light engine / OLED Product description For spotlights and downlights Housing with Snap-On feature for easy reflector mounting Luminous flux up to 2,92 lm at tp = 65 C High efficacy up to 147 lm/w

More information

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 15mm 2000lm 9x0 H EXC D50

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 15mm 2000lm 9x0 H EXC D50 w LED light engine / OLED Product description For spotlights and downlights Housing with Snap-On feature for easy reflector mounting Luminous flux up to 2,51 lm at tp = 65 C High efficacy up to 124 lm/w

More information

LED light engine / OLED LED linear / area

LED light engine / OLED LED linear / area LED light engine / OLED Module CLE G1 25mm ADV IND Modules CLE ADVANCED Product description LED modules for diffuse highbay applications Luminous flux: 26, lm per module Efficacy of the module up to 155

More information

LED light engines LED linear / area

LED light engines LED linear / area Module LLE G4 16mm 125lm ADV Module LLE ADVANCED Product description Ideal for compact linear luminaires designs Homogenous illumination thanks to small package distance SELV module the single module has

More information

LED modules LED linear / area. Module RLE 2x6 EXC2 OTD Modules RLE excite

LED modules LED linear / area. Module RLE 2x6 EXC2 OTD Modules RLE excite Module RLE 2x6 EXC2 OTD Modules RLE excite Product description High efficiency outdoor modules Suitable for harsh and humid outdoor conditions Tested acc. to salt spray test (IEC 668-2-52) and harmful

More information

LED modules LED linear / area

LED modules LED linear / area Module LLE G4 16mm 65lm ADV Module LLE advanced Product description Ideal for compact linear luminaires designs Homogenous illumination thanks to small package distance SELV module the single module has

More information

LED light engines LED linear / area. Module RLE PL1 EXC2 OTD Modules RLE EXCITE

LED light engines LED linear / area. Module RLE PL1 EXC2 OTD Modules RLE EXCITE Module RLE PL1 EXC2 OTD Modules RLE EXCITE Product description High efficiency outdoor modules Suitable for harsh and humid outdoor conditions Tested acc. to salt spray test (IEC 668-2-52) and harmful

More information

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER CAUTION: This equipment is designed for connection to mains voltages and must be used in accordance with this guide. If it is not, the safety protection

More information

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER ISOCON-6 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting

More information

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 FOOD EXC

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 FOOD EXC w Product description Application specific colours for attractive product presentation For spotlights Housing with Snap-On feature for easy reflector mounting Luminous flux up to 4,72 lm at tp = 65 C High

More information

A NEW GENERATION OF ECGs QUICKTRONIC MULTIWATT ONE FOR MANY THERE IS LIGHT. AND THERE IS OSRAM.

A NEW GENERATION OF ECGs QUICKTRONIC MULTIWATT ONE FOR MANY THERE IS LIGHT. AND THERE IS OSRAM. A NEW GENERATION OF QUICKTRONIC ONE FOR MANY THERE IS LIGHT. AND THERE IS OSRAM. ONE FOR MANY: THE NEW GENERATION OF VERSATILE. TOO MANY SPECIALISTS Without putting too fine a point on it, traditional

More information

LED light engine / OLED LED linear / area

LED light engine / OLED LED linear / area Module LLE G4 16mm 65lm ADV Module LLE ADVANCED Product description Ideal for compact linear luminaires designs Homogenous illumination thanks to small package distance SELV module the single module has

More information

LED light engine / OLED LED linear / area. Module QLE Shallow G1 ADV Modules QLE ADVANCED

LED light engine / OLED LED linear / area. Module QLE Shallow G1 ADV Modules QLE ADVANCED Module QLE Shallow G1 ADV Modules QLE ADVANCED Product description For square and rectangular ultra flat, wall-mounted, ceiling-mounted and suspended luminaries Backlighting depth of 3 mm can be realized

More information

LED light engine / OLED LED compact. Umodule STARK DLE CLASSIC STARK DLE 82,8 54,4. Ordering data

LED light engine / OLED LED compact. Umodule STARK DLE CLASSIC STARK DLE 82,8 54,4. Ordering data Product description Downlights High-flux LED module Low tolerances for colour temperatures (MacAdams 4) Compact design Excellent thermal management 1 NTC for temperature control High-power LED module in

More information

PHASED OUT. LED light engine / OLED LED linear / area. Module QLE Shallow G1 ADV Modules QLE ADVANCED

PHASED OUT. LED light engine / OLED LED linear / area. Module QLE Shallow G1 ADV Modules QLE ADVANCED Product description For square and rectangular ultra flat, wall-mounted, ceiling-mounted and suspended luminaries Backlighting depth of 3 mm can be realized Wide beam chip enables high homogeneity despite

More information

LED light engines LED linear / area. Module RLE G1 EXC OTD Modules RLE EXCITE

LED light engines LED linear / area. Module RLE G1 EXC OTD Modules RLE EXCITE Module RLE G1 EXC OTD Modules RLE EXCITE Product description High efficiency outdoor modules Suitable for harsh and humid outdoor conditions Tested acc. to salt spray test (IEC 668-2-52) and harmful gas

More information

PHASED OUT. LED light engines LED linear / area. Module RLE G1 EXC OTD Modules RLE EXCITE

PHASED OUT. LED light engines LED linear / area. Module RLE G1 EXC OTD Modules RLE EXCITE Product description High efficiency outdoor modules Suitable for harsh and humid outdoor conditions Tested acc. to salt spray test (IEC 668-2-52) and harmful gas test (GR-1217-CORE) Huge performance temperature

More information

LED light engines LED compact. Module SLE G7 ADV Modules SLE ADVANCED

LED light engines LED compact. Module SLE G7 ADV Modules SLE ADVANCED w LED light engines Module SLE G7 ADV Modules SLE ADVANCED Product description For spotlights and downlights For operating with SELV Driver Luminous flux up to 6,18 lm at tp = 65 C High efficacy up to

More information

LED light engines LED linear / area

LED light engines LED linear / area Module LLE 24x7-56mm 65lm HV ADV5 Modules LLE ADVANCED Product description Ideal for linear and panel lights 2 terminals for serial wiring Typ. luminous flux 16, 325, 65 and 1,3 lm Efficacy of the module

More information

LED light engines LED linear / area

LED light engines LED linear / area Module LLE 24x7-56mm 125lm HV ADV5 Modules LLE ADVANCED Product description Ideal for linear and panel lights 2 terminals for serial wiring Typ. luminous flux 325, 65, 1,25 and 2,4 lm Efficacy of the module

More information

LED light engines LED linear / area. Modules LLE ADVANCED

LED light engines LED linear / area. Modules LLE ADVANCED Module LLE 24mm 2000lm HV ADV5 Modules LLE ADVANCED Product description Ideal for linear and panel lights 2 terminals for serial wiring Typ. luminous flux 2,000 and 4,000 lm Efficacy of the module up to

More information

PHASED OUT. LED light engine / OLED LED compact. Module SLE G4 6mm R SNC, SLE G4 10mm R SNC China domestic Modules SLE ESSENCE

PHASED OUT. LED light engine / OLED LED compact. Module SLE G4 6mm R SNC, SLE G4 10mm R SNC China domestic Modules SLE ESSENCE w LED light engine / OLED Product description For general lighting application Typ. luminous flux category: 3/6/8/1,2 lm High efficacy up to 113 lm/w for the LED module at tp = 25 C Small LES (light emitting

More information

LED light engine / OLED LED compact. Umodule SLE G4 17mm R SNC China domestic umodule SLE ESSENCE

LED light engine / OLED LED compact. Umodule SLE G4 17mm R SNC China domestic umodule SLE ESSENCE w LED light engine / OLED Umodule SLE G4 17mm R SNC China domestic umodule SLE ESSENCE Product description For general lighting application Typ. luminous flux category: 2,/3, lm High efficacy up to 12

More information

LED light engines LED linear / area

LED light engines LED linear / area Module LLE G4 24mm 2000lm ADV Modules LLE ADVANCED Product description Ideal for linear and panel lights Typ. luminous flux 2,000 and 4,000 lm LED system solution with outstanding system efficacy up to

More information

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 17mm R SNC umodule SLE ESSENCE

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 17mm R SNC umodule SLE ESSENCE w LED light engine / OLED Product description For general lighting application Typ. luminous flux category: 2,/3, lm High efficacy up to 145 lm/w for the LED module at tp = 25 C Small LES (light emitting

More information

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 17mm TINGE R SNC umodule SLE ESSENCE

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 17mm TINGE R SNC umodule SLE ESSENCE w LED light engine / OLED Product description For general lighting application Typ. luminous flux category: 2,/3, lm High efficacy up to 18 lm/w for the LED module at tp = 25 C Small LES diameter (light

More information

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 EXC umodule SLE EXCITE

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 EXC umodule SLE EXCITE w LED light engine / OLED Product description For spotlights and downlights LES19 and LES23 modules Zhaga certified TIM variants for easy and fast assembly Housing with Snap-On feature for easy reflector

More information

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -A - Introduction - Thank for your purchasing MITSUBISHI ELECTRIC MELPRO TM D Series Digital Protection

More information

LED light engines LED linear / area

LED light engines LED linear / area Module LLE G4 24mm 1250lm ADV Modules LLE ADVANCED Product description Ideal for linear and panel lights SELV module the single module has a forward voltage < 60 V 4 terminals for parallel, serial or robot

More information

90 MCB MODULAR CIRCUIT BREAKERS FOR CIRCUIT PROTECTION

90 MCB MODULAR CIRCUIT BREAKERS FOR CIRCUIT PROTECTION MCB - MTC - MT - MTHP Technical data TYPE MTC MT MTC45 MTC60 MTC100 MT 45 MT 60 Rated current (In) (A) 2-32 6-32 6-32 6-40 1-63 Utilization category A A A A A Rated operational voltage (Ue) (V) 230/400-240/415

More information

LED light engines LED linear / area

LED light engines LED linear / area Module LLE G4 24x112 / 24x14 mm ADV Modules LLE ADVANCED Product description Ideal for linear lights 4 and 5 feet Length available in 1,12 mm (4 feet) and 1,4 mm (5 feet) Typ. luminous flux 65, 1,25 and

More information

Products for Luminaire Protection and Power Adjustment Products

Products for Luminaire Protection and Power Adjustment Products Products for uminaire Protection and Power Adjustment Products uminaire Protection evice For electronic devices When electronic components form part of lighting systems, it is often necessary to protect

More information

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P320-3 umodule SPOT PHASED OUT 46,5 39,5 35,5 NTC NTC LED + LED 8,5 4,5 8,5

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P320-3 umodule SPOT PHASED OUT 46,5 39,5 35,5 NTC NTC LED + LED 8,5 4,5 8,5 Product description Spotlights Downlights High-flux LED module Narrow colour temperature tolerance band Lifetime up to 5, hours Compact design Excellent thermal management 1 NTC for temperature control

More information

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 ESSENCE umodule SLE

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 ESSENCE umodule SLE w LED light engine / OLED Product description For general lighting application Typ. luminous flux category: 5,/3,/2, lm High efficacy up to 127 lm/w for the LED module at tp = 25 C High system efficacy

More information

Remote Display Unit. Installers Handbook Copyright 2001 AirSense Technology Ltd. LM Remote Display Unit Installers Handbook Issue 1.

Remote Display Unit. Installers Handbook Copyright 2001 AirSense Technology Ltd. LM Remote Display Unit Installers Handbook Issue 1. Remote Display Unit Installers Handbook Copyright 2001 AirSense Technology Ltd AirSense, ClassiFire, FastLearn PipeCAD, SenseNET, Stratos-HSSD and Stratos-Quadra are trademarks. HSSD is a Registered Trademark.

More information

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P320-2 umodule SPOT C.PHASED NTC

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P320-2 umodule SPOT C.PHASED NTC Product description Spotlights Downlights High-flux LED module Narrow colour temperature tolerance band Compact design Excellent thermal management 1 NTC for temperature control High-power LED in chip-on-board

More information

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P310-3 EM umodule SPOT PHASED OUT 39,5 35,5 NTC NTC

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P310-3 EM umodule SPOT PHASED OUT 39,5 35,5 NTC NTC Product description Spotlights Downlights High-flux LED module Narrow colour temperature tolerance band Lifetime up to 5, hours Compact design Excellent thermal management NTC for temperature control High-power

More information

To order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle

To order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle otor protection relays - T - FWIT Since % of -phase motor failures are due to load problems or loss of phase, the CROUZET range of motor protection relays is indispensable! models give motor protection

More information

LED light engines LED linear / area

LED light engines LED linear / area Module LLE G4 24mm 2000lm ADV Modules LLE ADVANCED Product description Ideal for linear and panel lights Typ. luminous flux 2,000 and 4,000 lm LED system solution with outstanding system efficacy up to

More information

90 MCB range Modular circuit breakers for circuit protection

90 MCB range Modular circuit breakers for circuit protection MCB - MTC - MT - MTHP Technical data TYPE MTC MT MTC45 MTC60 MTC100 MT 45 MT 60 Rated current (In) (A) 2-32 6-32 6-32 6-40 1-63 Utilization category A A A A A Rated operational voltage (Ue) (V) 230 / 400

More information

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P310-2 umodule SPOT C.PHASED NTC

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P310-2 umodule SPOT C.PHASED NTC Product description Spotlights Downlights High-flux LED module Narrow colour temperature tolerance band Compact design Excellent thermal management 1 NTC for temperature control High-power LED in chip-on-board

More information

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P330-3 EM umodule SPOT PHASED OUT NTC NTC LED + LED + LED EM LED EM

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P330-3 EM umodule SPOT PHASED OUT NTC NTC LED + LED + LED EM LED EM Product description Spotlights Downlights High-flux LED module Narrow colour temperature tolerance band Lifetime up to 5, hours Compact design Excellent thermal management NTC for temperature control High-power

More information

DC/DC regulator Input V Output up to 16 A

DC/DC regulator Input V Output up to 16 A PMC 4000 series Contents Product Program...................... 2 Mechanical Data...................... 3 Connections......................... 3 Absolute Maximum Ratings............. 4 Input...............................

More information

CTC 155 / 350 / 660 Dry-block calibrator

CTC 155 / 350 / 660 Dry-block calibrator CTC 155 / 350 / 660 Dry-block calibrator Wide temperature range: CTC-155: -25 to 155 C CTC-350: 28 to 350 C CTC-660: 28 to 660 C Fast calibration External reference sensor External sensor control Easy

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer HO-NP series I P N = 4, 6, 12, 15 A Ref: HO 4-NP, HO 6-NP, HO 12-NP, HO 15-NP For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary

More information

CLUSTERLITE CONTENTS MEGAMAN

CLUSTERLITE CONTENTS MEGAMAN CONTENTS Specifications for... 2.1 Maximum Temperature Declaration... 2.3 Lumen Maintenance Curve... 2.4 Vs. Temperature... 2.6 Run-up Time... 2.8 Specifications for Power Supply... 2.1 Line Drawings for

More information

5SJ4...-.HG Circuit Breakers to IEC and UL 489

5SJ4...-.HG Circuit Breakers to IEC and UL 489 Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is

More information

Distributing Tomorrow s Technologies For Today s Designs Toll-Free:

Distributing Tomorrow s Technologies For Today s Designs Toll-Free: 2W, Ultra-High Isolation DIP, Single & DC/DC s Key Features Low Cost 6 Isolation MTBF > 6, Hours Short Circuit Protection Input, and 24 Output,, 1, {, { and {1 Regulated Outputs Low Isolation Capacitance

More information

SCTP20 Programmable 2-Wire Temperature Transmitter, Head Mount

SCTP20 Programmable 2-Wire Temperature Transmitter, Head Mount 20 Programmable 2-Wire Temperature Transmitter, Head Mount Configurable Transmitters Description Each 20 2-wire transmitter is designed for measuring temperature using thermocouples or RTDs. The input

More information

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO. DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link

More information

PHOENIX CONTACT - 04/2016. Features

PHOENIX CONTACT - 04/2016. Features Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.

More information

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30 eries Features Best pressure transmission solution for small and middle sized project such as indoor heating and air conditioning, water and sewer, or incinerator, etc. Improves noise resistance and minimize

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T... Magnetic and Hydraulic-Magnetic Circuit Breaker 830-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of

More information

16 Input AC Block I/O Module

16 Input AC Block I/O Module 6 Input AC Module Cat. No. 79-6A0 Series B Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air flow through

More information

MAU100 Series. 1W, Miniature SIP, Single & Dual Output DC/DC Converters MINMAX. Key Features

MAU100 Series. 1W, Miniature SIP, Single & Dual Output DC/DC Converters MINMAX. Key Features W, Miniature SIP, Single & Dual Output DC/DC s Key Features Efficiency up to % 000 Isolation MTBF >,000,000 Hours Low Cost Input,, and Output 3.3,,9,,,{,{9,{ and { Temperature Performance -0] to +] UL

More information

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows: The basic PC software is supplied free with the recorder. There is an additional charge for the extensive Data Acquisition Software supplied with communication of RS-232/422/485 or Ethernet. The Ordering

More information

FAZ tripping characteristics at 30 C: B, C, D to IEC/EN FAZ tripping characteristics at 30 C: R to IEC/EN

FAZ tripping characteristics at 30 C: B, C, D to IEC/EN FAZ tripping characteristics at 30 C: R to IEC/EN FAZ, AZ High-Capacity Tripping Characteristics Moeller HPL011-001/00 1/07 FAZ tripping characteristics at 0 C: B, C, D to IEC/EN 0 9 FAZ tripping characteristics at 0 C: R to IEC/EN 0 97 t [s] 700 00 100

More information

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011 SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with

More information

Issued August DATA SHEET. 3VT3 MCCB up to 630 A

Issued August DATA SHEET. 3VT3 MCCB up to 630 A ssued August 9 DATA SHEET VT MCCB up to 6 A Based on Siemens Catalog V 6 8 Circuit breakers Switch disconnectors Technical specifications Specifications Type VT 76-AA6/6/56-AA, VT 76-AA6/6/56-AA Circuit

More information

DIN Timers TD. Options and ordering codes. Specification

DIN Timers TD. Options and ordering codes. Specification DIN imers D 17.5mm or 22.5mm DIN rail mounting Electronic imers Wide coil operation, 24V to 320V AC/DC Multi ime range / Multi function ON-Delay, OFF-Delay, Asymetrical, Star/Delta versions Perfect to

More information

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol with PROFIBUS-PA procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application 00 II () G FISCO The SINEAX VK 66 is a temperature transducer for use in aumation systems

More information

Operating Instructions for Digital Manometer. Model: MAN-SD

Operating Instructions for Digital Manometer. Model: MAN-SD Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5

More information

Thermal-Magnetic Circuit Breaker 2210-T2...

Thermal-Magnetic Circuit Breaker 2210-T2... Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring

More information

Technical Application Guide

Technical Application Guide LED MasterConnect LEDtube EM/Mains T8 Technical Application Guide Philips is now introducing a new line of connected LED lighting products. Philips MasterConnect LEDtube, which is Interact Ready, enables

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer HO-NSM series I PN = 8, 15, 25 A Ref: HO 8-NSM, HO 15-NSM, HO 25-NSM For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the

More information

Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000,

Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000, Digital Current Transducer HLSR-PW series I P N = 16... 50 A Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000, Bitstream output from on onboard Sigma Delta modulator. For the electronic measurement

More information

E2T0 DVP

E2T0 DVP 29-5-26 5116868-E2T DVP-11363-1 ENGLISH Thank you for choosing Delta s DVP series PLC. DVP4TC-E2 temperature measurement module receives 4 points of external thermocouple temperature sensors (J-type, K-type,

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer HO-NP/SP33 series I PN = 8, 15, 25 A Ref: HO 8-NP/SP33, HO 15-NP/SP33, HO 25-NP/SP33 For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the

More information

PRODUCT FAMILY DATASHEET LEDVANCE FLOODLIGHT LED

PRODUCT FAMILY DATASHEET LEDVANCE FLOODLIGHT LED LEDVANCE FLOODLIGHT LED LED floodlight luminaires AREAS OF APPLICATION Replacement for floodlights with halogen lamps Car parks and underpasses Garages Public areas Building facades Construction areas

More information

LuxSpace recessed high efficiency, visual comfort and a stylish design

LuxSpace recessed high efficiency, visual comfort and a stylish design Lighting LuxSpace recessed high efficiency, visual comfort and a stylish design LuxSpace Mini, recessed Customers are looking to optimize all their resources, and that means not just their running costs

More information

Non-Contact Safety Systems CMS

Non-Contact Safety Systems CMS Selection table for non-contact safety system // Evaluation units Connection Desi Read head contact assembly Assured switch-on distance S ao [mm] Assured switch-on distance S ar [mm] Number of outputs

More information

E6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders

E6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders Multi-turn High-precision Encoder Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders Reset function for easy origin alignment when built-into equipment. Multi-turn

More information

American Zettler AZ742 RELAY Datasheet

American Zettler AZ742 RELAY Datasheet American Zettler AZ74 RELAY Datasheet http://www.manuallib.com/american-zettler/az74-relay-datasheet.html FEATURES Dielectric strength 000 Vrms Low height:.7 mm Epoxy sealed version available 0 Amp switching

More information

MAU100 Series. 1W, Miniature SIP, Single & Dual Output DC/DC Converters MINMAX. Block Diagram. Key Features

MAU100 Series. 1W, Miniature SIP, Single & Dual Output DC/DC Converters MINMAX. Block Diagram. Key Features MAU Series W, Miniature SIP, Single & DC/DC s Key Features Efficiency up to 0 Isolation MTBF >,000,000 Hours Low Cost Input,, and Output 3.3,,9,,,{,{9,{ and { Temperature Performance -0 to UL 9V-0 Package

More information

32 Input AC Block I/O Module

32 Input AC Block I/O Module Input AC Module Cat. No. 79-A0 Series B Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air to flow through

More information

792A AC/DC Transfer Standard

792A AC/DC Transfer Standard 92A AC/DC Transfer Standard Technical Data Support for your most demanding ac measurement requirements ppm total uncertainty Traceable to national standards range: 2 mv to 00 V Frequency range: Hz to 1

More information