Bureau International des Poids et Mesures (BIPM),

Size: px
Start display at page:

Download "Bureau International des Poids et Mesures (BIPM),"

Transcription

1 Activity measurements of the radionuclides 18 F and 99m Tc for the NMISA, South Africa in the ongoing comparisons BIPM.RI(II)-K4.F-18 and BIPM.RI(II)-K4.Tc-99m (with erratum) C. Michotte 1, M. Nonis 1, M. W. Van Rooy 2, M. J. Van Staden 2, J. Lubbe 2. 1 Bureau International des Poids et Mesures (BIPM), 2 National Metrology Institute of South Africa (NMISA) Abstract In 2015, comparisons of activity measurements of 18 F and 99m Tc using the Transfer Instrument of the International Reference System (SIRTI) took place at the National Metrology Institute of South Africa (NMISA, South Africa). Ampoules containing about 25 kbq of 18 F and 99m Tc solutions were measured in the SIRTI for more than two half-lives. The NMISA standardized the activity in the ampoules by ionization chamber measurements traceable to 4 (LS) coincidence measurements. The comparisons, identifiers BIPM.RI(II)-K4.F-18 and BIPM.RI(II)-K4.Tc- 99m, are linked to the corresponding BIPM.RI(II)-K1.F-18 and BIPM.RI(II)-K1.Tc-99m comparisons and degrees of equivalence with the respective key comparison reference values have been evaluated. 1. Introduction Radionuclides are essential for nuclear medicine where very short-lived (much less than one day) radionuclides are used, particularly for imaging. The use of nuclear medicine is increasing with the accessibility of these radionuclides which are consequently of great interest to the National Metrology Institutes (NMIs) in terms of the standardization and SI traceability. However, sending ampoules of short-lived radioactive material to the Bureau International des Poids et Mesures (BIPM) for measurement in the International Reference System (SIR) [1] is only practicable for the NMIs that are based in Europe. Consequently, to extend the utility of the SIR and enable other NMIs to participate, a transfer instrument (SIRTI) has been developed at the BIPM with the support of the Consultative Committee for Ionizing Radiation CCRI(II) Transfer Instrument Working Group [2]. The BIPM ongoing K4 comparisons of activity measurements of 18 F (half-life T 1/2 = h; u = h [3]) 1 and of 99m Tc (half-life of (10) h [3]) are based on the SIRTI, a welltype NaI(Tl) crystal calibrated against the SIR, which is moved to each participating laboratory. The stability of the system is monitored using a 94 Nb reference source (half-life of (1 600) a [4]) from the Institute for Reference Materials and Measurements (IRMM, 1 Hereafter, the last digits of the standard uncertainties are given in parenthesis. 1/22

2 Geel), which also contains the 93m Nb isotope. The 18 F or 99m Tc count rate above a low-energy threshold, defined by the 93m Nb x-ray peak at 16.6 kev, is measured relative to the 94 Nb count rate above the same threshold. Once the threshold is set, a brass liner is placed in the well to suppress the 93m Nb contribution to the 94 Nb stability measurements. It should be noted that the uncertainty associated with the 94 Nb decay correction is negligible. The 99m Tc SIR ampoule is placed in the detector well with the brass liner to suppress the 99m Tc x-ray peaks from the counts. The 18 F SIR ampoule is placed in the detector well in a PVC liner to stop the + particles while minimizing the production of bremsstrahlung. No extrapolation to zero energy is carried out as all the measurements are made with the same threshold setting. The live-time technique using the MTR2 module from the Laboratoire National d Essais Laboratoire National Henri Becquerel, France (LNE-LNHB) [5] is used to correct for dead-time losses, taking into account the width of the oscillator pulses. The standard uncertainty associated with the live-time correction, due to the effect of finite frequency of the oscillator, is negligible. Similarly to the SIR, a SIRTI equivalent activity A E is deduced from the 18 F or 99m Tc and the 94 Nb counting results and the 18 F or 99m Tc activity measured by the NMI: A E corresponds to the inverse of a detection efficiency, i.e. A E is the activity of the source measured by the participant divided by the 18 F or 99m Tc count rate in the SIRTI expressed relatively to the 94 Nb count rate. The possible presence of impurity in the solution should be accounted for using - spectrometry measurements carried out by the NMI. The present K4 comparisons are linked to the corresponding BIPM.RI(II)-K1 comparisons through the calibration of the SIRTI against the SIR at the BIPM and consequently degrees of equivalence with the K1 key comparison reference value (KCRV) can be evaluated. The K4 99m Tc comparison results based on primary measurements carried out by the NMI, or ionization chamber measurements traceable to primary 99m Tc measurements made within one year prior to the K4 comparison, are eligible to be included in the KCRV. The protocol [6] and previous comparison results for the BIPM.RI(II)-K4 comparisons are available in the key comparison database of the CIPM Mutual Recognition Arrangement [7]. Publications concerning the details of the SIRTI and its calibration against the SIR can be found elsewhere [8, 9]. 2. Participants As detailed in the protocol, participation in the BIPM.RI(II)-K4 comparisons mainly concerns member states that are located geographically far from the BIPM and that have developed a primary measurement method for the radionuclide of concern. However, at the time of the comparison the National Metrology Institute (NMI) may decide for convenience to use a secondary method, for example a calibrated ionization chamber. In this case, the traceability of the calibration needs to be clearly identified. The present comparisons took place at the National Metrology Institute of South Africa (NMISA), South Africa, in November 2015, who used an ionization chamber calibrated by the 4 (LS) coincidence method one and two months prior to the comparison to standardize the 18 F and 99m Tc solutions, respectively. 2/22

3 3. The SIRTI at the NMISA The reproducibility and stability of the SIRTI at the NMISA were checked by measuring the count rate produced by the reference 94 Nb source No. 3, the threshold position (defined by the 93m Nb x-ray peak), the background count rate, the frequency of the oscillator No. 1 for the live-time correction and the room temperature as shown in Figure 1. The plots shown in the Figure represent the differences from the values indicated in the figure caption, using the appropriate units, as given, for each quantity measured Nb-94 Threshold Temperature Background Oscillator freq m Tc 18 F /11/ /11/ /11/ /11/ /11/2015 Date Figure 1: Fluctuation of the SIRTI at the NMISA. Black squares: 94 Nb No.1 count rate / s 1 above 7600 s 1 ; circle: threshold position / channel above 90 channels; stars: room temperature / C above 15 C; open squares: background count rate / s 1 above 70 s 1 ; triangles: frequency of the oscillator No.1 / Hz above Hz. The SIRTI was very stable during the comparison, except maybe a slight increase in the 94 Nb count rate on the last days and a corresponding slight decrease of the threshold position. However, the 99m Tc measurements are almost insensitive to the threshold position [8]. Consequently, it was decided to use the mean 94 Nb count rate to normalize the 99m Tc measurements (instead of individual 94 Nb results for the 18 F comparison) so that the small fluctuations observed in the 94 Nb results do not influence the 99m Tc comparison results. The mean 94 Nb No. 3 count rate, corrected for live-time, background and decay, measured at the NMISA is (5) s 1 which is in agreement with the weighted mean since the set-up of the system in March 2007, (25) s 1. Finally, the 94 Nb count rate was checked on the return of the SIRTI to the BIPM after the NMISA comparison, giving a value of (13) s 1 in agreement within standard uncertainty with the mean since /22

4 4. The 18 F and 99m Tc solutions standardized at the NMISA The 18 F and 99m Tc solutions measured in the SIRTI consisted in saline solutions diluted with de-ionized water. Two SIR ampoules were prepared from each diluted solution. Details are shown in Table 1, including any impurities, when present, as identified by the laboratory. The density and volume of the solutions in the ampoules conformed to the K4 protocol requirements. Drops (max. 3 mm diameter) of solution were observed in the cylindrical part of the ampoules (max. 1 cm above the solution). For the 18 F ampoules, many bubbles were observed in the solution and condensation in the upper part of the ampoule was noted (see Figure 2). The total volume of the bubbles was estimated in the range of 10 mm 3, corresponding to an effective solution density of g cm 3. For the condensation, a hypothetic 500 nm thick layer would correspond to a solution volume in the range of 0.1 mm 3. Monte-Carlo simulations indicate that the drops, bubbles and condensation observed should have a negligible effect on the SIRTI measurement result. The 99m Tc ampoules were not sealed, but closed with Parafilm. The 18 F and 99m Tc activities in the SIRTI ampoules were deduced from the measurement at the NMISA of each master solution in a Vinten Isocal IV well-type ionization chamber (IC) and a dilution factor of 1/ and 1/ , respectively. The IC had been calibrated for 18 F and 99m Tc by the NMISA one and two month, respectively, prior to the K4 comparison by the 4 (LS)β- coincidence method. The measurement results are summarized in Tables 2 and 3 while the uncertainty budgets of the NMISA primary measurements are given in appendix 2. Table 1: Characteristics of the solutions measured in the SIRTI Radionuclide 18 F (FDG # ) Density at Solvent Carrier / mol dm 3 / g g 1 20 C Ampoule / g cm 3 number de-ionized water Mass / g Impurity* m Tc de-ionized water * Ratio of the impurity activity to the main radionuclide activity at the reference date # Fluorodesoxyglucose 4/22

5 Figure 2: 18 F ampoule where drops, bubbles and condensation are noted Table 2: The 18 F and 99m Tc standardizations by the NMISA Radionuclide 18 F Measurement method ACRONYM* IC calibrated 4P-IC-GR in Oct by 4 (LS)β- coinc. 4P-LS-BP-NA-GR-CO Activity conc. / kbq g 1 Standard uncert. / kbq g Reference date YYYY-MM-DD :00 UTC Half-life used by the NMI / h (23) IC calibrated 4P-IC-GR m Tc in Sept by 4 (LS)β- coinc. 4P-LS-BP-NA-GR-CO * See appendix :00 UTC (10) 5/22

6 Table 3: The NMISA uncertainty budgets for the activity measurement of the 18 F and 99m Tc ampoules (Nov. 2015) Uncertainty contributions due to Evaluation method Relative standard uncert F Comments Relative sensitivity factors Relative standard uncert m Tc Comments Relative sensitivity factors Counting statistics A 5 Weighing B 1 Statist. analysis of 306 values Mass for source prep Statist. analysis of 153 values 1 1 Mass for source prep Background A 0.2 Statist. analysis of 201 values Time accuracy of PC clock B 0.1 Accuracy of time stamping Decay correction B 1.5 From literature value uncertainty for the half-life Calibration factor of IC (see appendix 2) B 35 From primary standardization IC cyclical variability B 50 IC long term cyclical behaviour Impurities B 0.0 HPGe measurements Statist. analysis of 201 values Accuracy of time stamping From literature value uncertainty for the half-life From primary standardization 1 50 IC long term cyclical behaviour 0.0 HPGe measurements Relative combined standard uncertainty /22

7 5. The 18 F and 99m Tc measurements in the SIRTI at the NMISA The maximum count rate corrected for live-time in the NaI(Tl) was s 1 which conforms with the limit of s 1 set in the protocol [6]. In addition a relative standard uncertainty of and for 18 F and 99m Tc respectively, was added to take account of a possible drift in the SIRTI at high count rate [8]. The time of each TI measurement was obtained from the synchronization of the laptop with a local NTP time server. In principle, the live-time correction should be modified to take into account the decaying count rate [10]. In the present experiments, the duration of the measurements made at high rate has been limited to 300 s and 1500 s for 18 F and 99m Tc respectively, so that the relative effect of decay on the live-time correction is less than one part in Two ampoules of each of the 18 F and 99m Tc solutions were measured alternatively for more than two half-lives and the results are shown in Figures 3a and 3b. The reduced chi-squared values evaluated for these series of measurements are 0.83 and 0.71 for 18 F and 99m Tc, respectively, showing that the data are consistent. The absence of significant trend confirms the stability of the SIRTI and the absence of significant impurity in the solutions. The uncertainty budgets for the SIRTI measurements of the 18 F and 99m Tc ampoules are given in Table 4a and 4b. Further details are given in reference [8]. 6. Comparison results and degrees of equivalence The weighted mean and uncertainty of all the measured A E values is calculated taking into account correlations. In the case of 18 F, the last 10 measurements shown in Figure 3a were not considered as the count rate in the SIRTI was lower than the limit of 2000 s 1 set in the protocol. The standard uncertainty u(a E ) is obtained by adding quadratically the SIRTI combined uncertainty from Tables 4a and 4b and the uncertainty stated by the participant for the 18 F and 99m Tc measurements (see Table 2). The correlation between the NMISA and the BIPM due to the use of the same 99m Tc half-life is negligible in view of the small contribution of this half-life to the combined uncertainty of the measurements. The K4 comparison results are given in Table 5 as well as the linked results A e in the corresponding BIPM.RI(II)-K1 comparisons which were obtained by multiplying A E by the linking factors L = (18) for 18 F and (23) for 99m Tc. The linking factors were obtained through the measurement of 18 F and 99m Tc ampoules from the LNE-LNHB, the NPL and a commercial company in both the SIRTI and the SIR [9]. 7/22

8 Figure 3a: The 18 F measurement results in the SIRTI at the NMISA. The uncertainty of the 18 F activity concentration and of the 94 Nb mean count rate, which are both constant over all the measurements, are not included in the uncertainty bars shown on the graph. Figure 3b: As for Figure 3a, but for the 99m Tc. 8/22

9 Table 4a: Uncertainty budgets for the SIRTI measurement of the 18 F ampoules Uncertainty contributions due to 18 F meas. including livetime, background, decay corrections and threshold setting 94 Nb measurement including live-time, background and threshold setting Long-term stability of the SIRTI Nb reference source No.3 instead of No.1 Effect of decay on the live-time correction SIRTI drift at high count rate Ampoule dimensions Ampoule filling height Solution density Unseen droplet on the walls of the ampoule top Comments Standard uncertainty of the weighted mean of 30 measurements, taking into account the correlation due to the 18 F half-life Standard deviation of 10 measurements and sensitivity to threshold setting Weighted standard deviation of 77 series, each series consisting of 10 measurements Weighted standard deviation of 53 series, each series consisting of 10 measurements Maximum measurement duration evaluated from [11] Mean possible drift over all 18 F measurements at the NMISA. From the IRMM report [12] and sensitivity coefficients from Monte-Carlo simulations Solution volume is 3.6(1) cm 3 ; sensitivity coefficients from Monte-Carlo simulations Between 1 g/cm 3 and 1.01 g/cm 3 as requested in the protocol; sensitivity coefficients from Monte-Carlo simulations Evaluation method Relative standard uncert A 1.9 A/B 1.8 A 0.3 A 0.3 B < 1 B 2 B 2* B 2 B 0.7 Evaluated by Monte-Carlo simulation B 1 Relative combined standard uncertainty 4.2 * Included in the type A uncertainty of the measurements of 2 ampoules of 18 F 9/22

10 Table 4b: Uncertainty budgets for the SIRTI measurement of the 99m Tc ampoules Uncertainty contributions due to 99m Tc meas. including live-time, background and decay corrections 94 Nb measurement including live-time, background and threshold setting Long-term stability of the SIRTI Nb reference source No.3 instead of No.1 Effect of decay on the live-time correction SIRTI drift at high count rate Ampoule dimensions Ampoule filling height Solution density Unseen droplet on the walls of the ampoule top Comments Standard uncertainty of the weighted mean of 36 measurements, taking into account the correlation due to the 99m Tc half-life Weighted standard deviation of 7 series, each series consisting of 10 measurements Weighted standard deviation of 77 series, each series consisting of 10 measurements Weighted standard deviation of 53 series, each series consisting of 10 measurements Maximum measurement duration evaluated from [11] Mean possible drift over all 99m Tc measurements at the NMISA. From the IRMM report [12] and sensitivity coefficients from Monte-Carlo simulations Solution volume is 3.6(1) cm 3 ; sensitivity coefficients from Monte-Carlo simulations Between 1 g/cm 3 and 1.01 g/cm 3 as requested in the protocol; sensitivity coefficients from Monte-Carlo simulations Evaluation method Relative standard uncert A 1.7 A 0.7 A 0.3 A 0.3 B < 1 B 3 B 8 B 3* B 0.8 Evaluated by Monte-Carlo simulation B 2 Relative combined standard uncertainty 9.1 * Included in the type A uncertainty of the measurements of 2 ampoules of 99m Tc Table 5: BIPM.RI(II)-K4. comparison results and link to the BIPM.RI(II)-K1 comparisons Radionuclide Measurement method ACRONYM* IC calibrated 18 4P-IC-GR F in Oct by 4 (LS)β- coinc. 4P-LS-BP-NA-GR-CO IC calibrated 99m 4P-IC-GR Tc in Sept by 4 (LS)β- coinc. 4P-LS-BP-NA-GR-CO * See appendix 1 Solution volume (calculated) /cm 3 A E /kbq u(a E ) /kbq Linked A e /kbq u(a e ) /kbq and /22

11 Every participant in the K4 comparison is entitled to have one result included in the key comparison database (KCDB) as long as the laboratory is a signatory or designated institute listed in the CIPM MRA, and the result is valid (i.e., not older than 20 years). Normally, the most recent result is the one included. Any participant may withdraw its result only if all the participants agree. The KCRV for 18 F has been defined in the frame of the BIPM.RI(II)-K1.F-18 comparison using direct contributions to the SIR, and is equal to (24) kbq [13]. The key comparison reference value (KCRV) for 99m Tc has been defined in the frame of the BIPM.RI(II)-K1.Tc-99m comparison using direct contributions to the SIR and, as agreed by the CCRI(II) in 2015, the SIRTI results for NIST, KRISS, NIM, LNMRI/IRD and IFIN-HH, giving a value of (310) kbq as detailed in reference [14]. The degree of equivalence of a particular NMI, i, with the KCRV is expressed as the difference D i with respect to the KCRV D KCRV i Ae (1) i and the expanded uncertainty (k = 2) of this difference, U i, known as the equivalence uncertainty, hence Ui 2u( Di ), (2) taking correlations into account as appropriate [15]. The degree of equivalence between any pair of NMIs, i and j, is expressed as the difference D ij in their results D D D A A (3) and the expanded uncertainty of this difference U ij where U ij 2 ij i j ei e j ij i j ei ej 2 u ( D ) 4 u u - 2u( A, A ) (4) where any obvious correlations between the NMIs (such as a traceable calibration) are subtracted using the covariance u(a ei, A ej ), as is the correlation coming from the link of the SIRTI to the SIR. The covariance between two participants in the K4 comparison is given by u(a ei, A ej ) = A ei A ej (u L /L) 2 (5) where u L is the standard uncertainty of the linking factor L given above. However, the CCRI decided in 2011 that these pair-wise degrees of equivalence no longer need to be published as long as the methodology is explained. Tables 6a and 6b show the matrices of the degrees of equivalence with the KCRV as they will appear in the KCDB. Only results not older than 20 years are shown. It should be noted that for consistency within the KCDB, a simplified level of nomenclature is used with A ei replaced by x i. The introductory text is that agreed for the comparison. The graph of the degrees of equivalence with respect to the KCRV (identified as x R in the KCDB), is shown in Figure 4a and Figure 4b. The graphical representation indicates in part the degree of equivalence between the NMIs but obviously does not take into account the correlations between the different NMIs. 11/22

12 Conclusion The BIPM ongoing key comparisons for 18 F (BIPM.RI(II)-K4.F-18) and 99m Tc (BIPM.RI(II)- K4.Tc-99m) currently comprise four and nine results, respectively, and are linked to the corresponding BIPM.RI(II)-K1 comparisons. The last results in these K4 comparisons, for NMISA (South Africa), have been analysed with respect to the KCRVs determined for 18 F and 99m Tc in the frame of the corresponding K1 comparisons. The degrees of equivalence have been approved by the CCRI(II) and are published in the BIPM key comparison database. Other results may be added when other NMIs contribute with 18 F and 99m Tc activity measurements to the K4 or K1 comparisons or take part in other linked Regional Metrology Organization comparisons. It should be noted that the final data in this paper, while correct at the time of publication, will become out-of-date as NMIs make new comparisons. The formal results under the CIPM MRA [7] are those available in the KCDB. 12/22

13 Table 6a. Introductory text and table of degrees of equivalence for 18 F Key comparison BIPM.RI(II)-K1.F-18 MEASURAND : Equivalent activity of 18 F Key comparison reference value: the SIR reference value for this radionuclide is x R = kbq with a standard uncertainty, u R = 24 kbq (see Final Report). The value x i is the equivalent activity for laboratory i. The degree of equivalence of each laboratory with respect to the reference value is given by a pair of terms: D i = (x i - x R ) and U i, its expanded uncertainty (k = 2), both expressed in MBq, and U i = 2((1-2w i )u i 2 + u R 2 ) 1/2 where w i is the weight of laboratory i contributing to the calculation of x R. Linking BIPM.RI(II)-K4.F-18 to BIPM.RI(II)-K1.F-18 The value x i is the SIRTI equivalent activity for laboratory i participant in BIPM.RI(II)-K4.F-18 multiplied by the linking factor to BIPM.RI(II)-K1.F-18 (see Final report). The degree of equivalence of laboratory i participant in BIPM.RI(II)-K4.F-18 with respect to the key comparison reference value is given by a pair of terms: D i = (x i - x R ) and U i, its expanded uncertainty (k = 2), both expressed in MBq. The approximation U i = 2(u i 2 + u R 2 ) 1/2 is used in the following table as none of these laboratories contributed to the KCRV. Linking CCRI(II)-K3.F-18 to BIPM.RI(II)-K1.F-18 The value x i is the equivalent activity for laboratory i participant in CCRI(II)-K3.F-18 having been normalized to the value of the NPL and the LNE-LNHB (2002) combined as the link. The degree of equivalence of laboratory i participant in CCRI(II)-K3. with respect to the key comparison reference value is given by a pair of terms: D i = (x i - x R ) and U i, its expanded uncertainty (k = 2), both expressed in MBq. The approximation U i = 2(u i 2 + u R 2 ) 1/2 is used in the following table as none of these laboratories contributed to the KCRV. Linking APMP.RI(II)-K3.F-18 to BIPM.RI(II)-K1.F-18 The value x i is the equivalent activity for laboratory i participant in APMP.RI(II)-K3.F-18 having been normalized to the value of the NPL and the LNE-LNHB (2002) combined as the link. 13/22

14 The degree of equivalence of laboratory i participant in APMP.RI(II)-K3. with respect to the key comparison reference value is given by a pair of terms: D i = (x i - x R ) and U i, its expanded uncertainty (k = 2), both expressed in MBq. The approximation U i = 2(u i 2 + u R 2 ) 1/2 is used in the following table as this laboratory did not contribute to the KCRV. These statements make it possible to extend the BIPM.RI(II)-K1.F-18 matrices of equivalence to all participants in the CCRI(II)-K3.F-18, the APMP.RI(II)-K3.F-18 and the BIPM.RI(II)-K4.F-18 comparisons. Lab i D i U i / MBq IRA BEV CIEMAT PTB LNE-LNHB VNIIM NPL ENEA-INMRI NMISA ANSTO CMI-IIR NIST INER /22

15 Figure 4a. Graph of degrees of equivalence with the KCRV for 18 F NOT VALID, See erratum p. 22 (as it appears in Appendix B of the MRA) N.B. The right-hand axis gives approximate relative values only 15/22

16 Table 6b. Table of degrees of equivalence and introductory text for 99m Tc Key comparison BIPM.RI(II)-K1.Tc-99m MEASURAND : Equivalent activity of 99m Tc Key comparison reference value: the SIR reference value for this radionuclide is x R = MBq with a standard uncertainty, u R = 0.31 MBq (see Final Report). The value x i is the equivalent activity for laboratory i. The degree of equivalence of each laboratory with respect to the reference value is given by a pair of terms: D i = (x i - x R ) and U i, its expanded uncertainty (k = 2), both expressed in MBq, and U i = 2((1-2w i )u i 2 + u R 2 ) 1/2 where w i is the weight of laboratory i contributing to the calculation of x R. Linking BIPM.RI(II)-K4.Tc-99m to BIPM.RI(II)-K1.Tc-99m The value x i is the SIRTI equivalent activity for laboratory i participant in BIPM.RI(II)-K4.Tc-99m multiplied by the linking factor to BIPM.RI(II)-K1.Tc-99m (see Final report). The degree of equivalence of laboratory i participant in BIPM.RI(II)-K4.Tc-99m with respect to the key comparison reference value is given by a pair of terms: D i = (x i - x R ) and U i, its expanded uncertainty (k = 2), both expressed in MBq, U i = 2((1-2w i )u i 2 + u R 2 ) 1/2 where w i is the weight of laboratory i contributing to the calculation of x R. These statements make it possible to extend the BIPM.RI(II)-K1.Tc-99m matrices of equivalence to the other participants in BIPM.RI(II)-K4.Tc-99m. 16/22

17 Lab i D i U i / MBq BEV MKEH PTB LNE-LNHB NPL NIST KRISS NMIJ NIM CNEA LNMRI/IRD IFIN-HH VNIIM ENEA-INMRI NMISA /22

18 Figure 4b. Graph of degrees of equivalence with the KCRV for 99m Tc (as it appears in Appendix B of the MRA) N.B. The right-hand axis gives approximate relative values only 18/22

19 References [1] Ratel G., 2007, The Système International de Référence and its application in key comparisons, Metrologia 44(4), S7-S16. [2] Remit of the CCRI(II) Transfer Instrument Working Group, 2009, CCRI(II) working document CCRI(II)/ [3] Bé M.-M., Chisté V., Dulieu C., Browne E., Chechev V., Kuzmenko N., Helmer R., Nichols A., Schönfeld E., Dersch R., 2004, Table of radionuclides, Monographie BIPM-5, volume 1. [4] NUDAT2.5, National Nuclear Data Center, Brookhaven National Laboratory, based on ENSDF and the Nuclear Wallet Cards. [5] Bouchard J., 2000, Appl. Radiat. Isot. 52, [6] SIR Transfer Instrument. Protocol for the ongoing comparisons on site at the NMIs, BIPM.RI(II)-K4. Published on the CIPM MRA KCDB website. [7] CIPM MRA: Mutual recognition of national measurement standards and of calibration and measurement certificates issued by national metrology institutes, International Committee for Weights and Measures, 1999, 45 pp. [8] Michotte C. et al., The SIRTI, a new tool developed at the BIPM for comparing activity measurements of short-lived radionuclides world-wide, Rapport BIPM-2013/02. [9] Michotte C. et al., Calibration of the SIRTI against the SIR and trial comparison of 18 F and 99m Tc at the NPL. In preparation. [10] Baerg A.P. et al., 1976, Live-timed anti-coincidence counting with extending dead-time circuitry, Metrologia 12, [11] Fitzgerald R., 2016, Corrections for the combined effects of decay and dead time in livetimed counting of short-lived radionuclides, Appl. Radiat. Isot. 109, [12] Sibbens G., 1991, A comparison of NIST/SIR-, NPL-, and CBNM 5 ml ampoules, GE/R/RN/14/91, CEC-JRC Central Bureau for Nuclear Measurements, Belgium. [13] Michotte C. et al., Update of the BIPM comparison BIPM.RI(II)-K1.F-18 of activity measurements of the radionuclide 18 F to include the 2010 result of the LNE-LNHB (France). Metrologia, 2016, 53, Tech. Suppl., [14] Michotte C., et al., Activity measurements of the radionuclide 99m Tc for the VNIIM, Russia and the ENEA-INMRI, Italy in the ongoing comparison BIPM.RI(II)-K4.Tc- 99m and update of the KCRV of the BIPM.RI(II)-K1.Tc-99m comparison, in preparation. [15] Ratel G., 2005, Evaluation of the uncertainty of the degree of equivalence, Metrologia 42, /22

20 Appendix 1. Acronyms used to identify different measurement methods Each acronym has six components, geometry-detector (1)-radiation (1)-detector (2)-radiation (2)-mode. When a component is unknown,?? is used and when it is not applicable 00 is used. Geometry acronym Detector acronym 4 4P proportional counter PC defined solid angle SA press. prop. counter PP 2 2P liquid scintillation counting LS undefined solid angle UA NaI(Tl) NA Ge(HP) Ge(Li) Si(Li) CsI(Tl) ionization chamber grid ionization chamber Cerenkov light detector calorimeter solid plastic scintillator PIPS detector Radiation acronym Mode acronym positron PO efficiency tracing ET beta particle BP internal gas counting IG Auger electron AE CIEMAT/NIST CN conversion electron CE sum counting SC mixed electrons ME coincidence CO bremsstrahlung BS anti-coincidence AC gamma rays GR coincidence counting with efficiency tracing X - rays XR anti-coincidence counting with efficiency tracing photons (x + ) PH triple-to-double coincidence ratio counting alpha - particle AP selective sampling SS mixture of various radiations GH GL SL CS IC GC LC CA SP PS CT AT TD MX high efficiency HE Examples method 4 (PC) -coincidence counting 4 (PPC) -coincidence counting eff. trac. defined solid angle -particle counting with a PIPS detector 4 (PPC)AX- (Ge(HP))-anticoincidence counting 4 CsI-,AX, counting calibrated IC internal gas counting acronym 4P-PC-BP-NA-GR-CO 4P-PP-MX-NA-GR-CT SA-PS-AP P-PP-MX-GH-GR-AC 4P-CS-MX HE 4P-IC-GR P-PC-BP IG 20/22

21 Appendix 2. Uncertainty budgets for the NMISA primary measurements of 18 F (Oct. 2015) and 99m Tc (Sept. 2015) 4P-LS-BP-NA-GR-CO Uncertainty contributions due to Evaluation method 18 F Relative standard uncert Relative sensitivity factors 99m Tc Relative standard uncert Relative sensitivity factors Comments Counting statistics A Statist. analysis of 20 values Weighing B Mass of sources Dead time B D ± 0.05 s Background A Background square root statist. applied Coincidence resolving time B R ± 0.01 s Counting time B Calibration of timer Adsorption B F : (1) / 99m Tc : (2) Decay correction B From literature value uncert. for the half-life Extrapolation of effic. curve B Alternative fits to data Afterpulse correction B Beta-plus branching ratio: (19) B 20 1 From literature value uncertainty in Betaplus branching ratio Impurities B HPGe measurements Relative combined standard uncertainty (1) Count rates after multiple rinsings relative to the expected count rates if rinsings were not done (2) Count rate measurements after multiple rinsings comparable to background count rates 21/22

22 Erratum In the present paper, degrees of equivalence for NMISA, South Africa, have been included in the comparison of 18 F activity measurements BIPM.RI(II)-K4.F-18. The corresponding Table 6a is correct. However an error in the Graph 4a happened and the uncertainty bars for the BIPM.RI(II)-K1.F-18 comparison results in red are wrong. The correct graph is shown below. Corrected Figure 4a. Graph of degrees of equivalence with the KCRV for 18 F It should be noted that no error took place in the graph appearing on the Key Comparison Data Base on line. 22/22

Activity measurements of the radionuclide 99m Tc for the NIST, USA in the ongoing comparison BIPM.RI(II)-K4.Tc-99m. C. Michotte 1, R.

Activity measurements of the radionuclide 99m Tc for the NIST, USA in the ongoing comparison BIPM.RI(II)-K4.Tc-99m. C. Michotte 1, R. Activity measurements of the radionuclide 99m Tc for the NIST, USA in the ongoing comparison BIPM.RI(II)-K4.Tc-99m C. Michotte 1, R. Fitzgerald 2 1 Bureau International des Poids et Mesures (BIPM), 2 National

More information

Activity measurements of the radionuclide 153 Sm for the ANSTO, Australia in the ongoing comparison BIPM.RI(II)-K1.Sm-153

Activity measurements of the radionuclide 153 Sm for the ANSTO, Australia in the ongoing comparison BIPM.RI(II)-K1.Sm-153 Activity measurements of the radionuclide 153 Sm for the ANSTO, Australia in the ongoing comparison BIPM.RI(II)-K1.Sm-153 G. Ratel*, C. Michotte*, M. Reinhard, D. Alexiev, L. Mo *BIPM, ANSTO, Australia

More information

Activity measurements of the radionuclide 99m Tc for the CNEA, Argentina and the LNMRI/IRD, Brazil in the ongoing comparison BIPM.RI(II)-K4.

Activity measurements of the radionuclide 99m Tc for the CNEA, Argentina and the LNMRI/IRD, Brazil in the ongoing comparison BIPM.RI(II)-K4. Activity measurements of the radionuclide 99m Tc for the CNEA, Argentina and the LNMRI/IRD, Brazil in the ongoing comparison BIPM.RI(II)-K4.Tc-99m C. Michotte 1, M. Nonis 1, P. Arenillas 2, G. Cerutti

More information

C. Michotte*, G. Ratel* and S. Courte*, T. Dziel #, A. Listkowska #, I. Csete, K. Rózsa, L. Szücs, A. Zsinka, C. Fréchou**, C. Bobin**, S.

C. Michotte*, G. Ratel* and S. Courte*, T. Dziel #, A. Listkowska #, I. Csete, K. Rózsa, L. Szücs, A. Zsinka, C. Fréchou**, C. Bobin**, S. Update of the BIPM comparison BIPM.RI(II)-K1.Am-241 of activity measurements of the radionuclide 241 Am to include the 2009 results of the POLATOM (Poland), MKEH (Hungary) and the 2011 results of the LNE-LNHB

More information

Activity measurements of the radionuclide 111 In for the LNE-LNHB, France in the ongoing comparison BIPM.RI(II)-K1.In-111

Activity measurements of the radionuclide 111 In for the LNE-LNHB, France in the ongoing comparison BIPM.RI(II)-K1.In-111 Activity measurements of the radionuclide 111 In for the LNE-LNHB, France in the ongoing comparison BIPM.RI(II)-K1.In-111 C. Michotte*, G. Ratel*, S. Courte*, E. Verdeau, M.-N. Amiot *BIPM, LNE-LNHB, France

More information

C. Michotte 1, G. Ratel 1, S. Courte 1, Y. Nedjadi 2, C. Bailat 2, L. Johansson 3, Y. Hino 4. Abstract

C. Michotte 1, G. Ratel 1, S. Courte 1, Y. Nedjadi 2, C. Bailat 2, L. Johansson 3, Y. Hino 4. Abstract Update of the BIPM comparison BIPM.RI(II)-K1.Ho-166m activity measurements to include the IRA and the NPL and a re-evaluation of the degrees of equivalence for the APMP.RI(II)-K2.Ho-166m comparison C.

More information

National Physical Laboratory (NPL), UK

National Physical Laboratory (NPL), UK BIPM comparison BIPM.RI(II)-K1.Lu-177 of activity measurements of the radionuclide 177 Lu for the NPL (UK) and the IRMM (EU), with linked results for the CCRI(II)-K2.Lu-177 comparison C. Michotte, G. Ratel,

More information

BIPM.RI(II)-K1.F-18, BIPM.RI(II)-K4.F18, CCRI(II)-K3.F-18 and APMP.RI(II)-K3.F-18

BIPM.RI(II)-K1.F-18, BIPM.RI(II)-K4.F18, CCRI(II)-K3.F-18 and APMP.RI(II)-K3.F-18 BIPM.RI(II)-K1.F-18, BIPM.RI(II)-K4.F18, CCRI(II)-K3.F-18 and APMP.RI(II)-K3.F-18 MEASURAND : Equivalent activity of 18 F Key comparison BIPM.RI(II)-K1.F-18 result of measurement carried out in the SIR

More information

G. Ratel 1, C. Michotte 1, D. Kryeziu 1, M. Moune 2, A. Iwahara 3. Abstract

G. Ratel 1, C. Michotte 1, D. Kryeziu 1, M. Moune 2, A. Iwahara 3. Abstract Update of the BIPM comparison BIPM.RI(II)-K1.Cr-51 to include new activity measurements for the LNE-LNHB (France) and the pilot study result of the LNMRI (Brazil) G. Ratel 1, C. Michotte 1, D. Kryeziu

More information

G. Ratel 1, C. Michotte 1, M. Sahagia 2, A. Yunoki 3. Abstract

G. Ratel 1, C. Michotte 1, M. Sahagia 2, A. Yunoki 3. Abstract Update of the BIPM comparison BIPM.RI(II)-K1.Ba-133 of activity measurements of the radionuclide 133 Ba to include the results of the IFIN-HH (Romania) and the NMIJ (Japan) G. Ratel 1, C. Michotte 1, M.

More information

G. Ratel*, C. Michotte*, Y. Hino** *BIPM and **NMIJ, Japan

G. Ratel*, C. Michotte*, Y. Hino** *BIPM and **NMIJ, Japan Update of the BIPM comparison BIPM.RI(II)-K1.Ce-139 of activity measurements of the radionuclide 139 Ce to include the 2004 NMIJ result and links for the 2004 regional comparison APMP.RI(II)-K2.Ce-139

More information

The metrology of radioactivity. C. Michotte, BIPM

The metrology of radioactivity. C. Michotte, BIPM The metrology of radioactivity C. Michotte, BIPM SUMMARY Introduction Nuclear data of interest in activity measurements Activity measurement methods (primary and secondary) Monte Carlo simulations The

More information

BIPM.RI(II)-K1.Am-241, CCRI(II)-K2.Am-241, and COOMET.RI(II)-K2.Am.241

BIPM.RI(II)-K1.Am-241, CCRI(II)-K2.Am-241, and COOMET.RI(II)-K2.Am.241 MEASURAND : Key comparison BIPM.RI(II)-K1.Am-241 x i : u i : Equivalent activity of 241 Am result of measurement carried out in the SIR for the sample submitted by laboratory i combined standard uncertainty

More information

Bureau International des Poids et Mesures (BIPM), Sèvres. National Institute of Standards and Technology (NIST), USA. Becquerel (LNE-LNHB), France

Bureau International des Poids et Mesures (BIPM), Sèvres. National Institute of Standards and Technology (NIST), USA. Becquerel (LNE-LNHB), France BIPM comparison BIPM.RI(II)-K1.I-131 of activity measurements of the radionuclide 131 I for the NMIJ (Japan), the NIST (USA) and the LNE-LNHB (France), with linked results for the APMP.RI(II)-K2.I-131

More information

BUREAU INTERNATIONAL DES POIDS ET MESURES

BUREAU INTERNATIONAL DES POIDS ET MESURES BUREAU INTERNATIONAL DES POIDS ET MESURES The SIRTI : a new tool developed at the BIPM for comparing activity measurements of short-lived radionuclides world-wide C. Michotte, M. Nonis, C. Bobin, T. Altzizoglou,

More information

International comparison of activity measurements of a solution of tritiated water CCRI(II)-K2.H-3

International comparison of activity measurements of a solution of tritiated water CCRI(II)-K2.H-3 International comparison of activity measurements of a solution of tritiated water CCRI(II)-K2.H-3 by G. Ratel and C. Michotte Bureau International des Poids et Mesures F-92312 Sèvres Cedex, France Abstract:

More information

BUREAU INTERNATIONAL DES POIDS ET MESURES

BUREAU INTERNATIONAL DES POIDS ET MESURES 1 BUREAU INTERNATIONAL DES POIDS ET MESURES International comparison of activity measurements of a solution of 3 H (January 2009) Participating laboratory: T ½ = (4 496.862 d; u = 9.131 d)* Ampoule number

More information

C. Michotte, G. Ratel, S. Courte and L. Joseph 1 BIPM, Sèvres and 1 Bhabha Atomic Research Centre (BARC), India

C. Michotte, G. Ratel, S. Courte and L. Joseph 1 BIPM, Sèvres and 1 Bhabha Atomic Research Centre (BARC), India BIPM comparison BIPM.RI(II)-K1.Zn-65 of activity measurements of the radionuclide 65 Zn for the BARC (India) with linked results for the CCRI(II)-K2.Zn-65 comparison C. Michotte, G. Ratel, S. Courte and

More information

Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the LNE-LNHB, France and the BIPM in 60 Co gamma radiation

Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the LNE-LNHB, France and the BIPM in 60 Co gamma radiation Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the LNE-LNHB, France and the BIPM in 60 Co gamma radiation C. Kessler 1, D.T. Burns 1, F. Delaunay 2, M. Donois 2 1 Bureau International des Poids

More information

*BIPM, # CNEA, BARC, $ NRC, **NIM. Abstract

*BIPM, # CNEA, BARC, $ NRC, **NIM. Abstract Update of the BIPM comparison BIPM.RI(II)-K1.Co-60 of activity measurements of the radionuclide 60 Co to include the 2011 result of the CNEA (Argentina), the 2012 results of the BARC (India) and the NRC

More information

Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the NIM, China and the BIPM in 60 Co gamma radiation

Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the NIM, China and the BIPM in 60 Co gamma radiation ey comparison BIPM.RI(I)-1 of the air-kerma standards of the NIM, China and the BIPM in 60 Co gamma radiation C. essler 1, D. Burns 1,. Wang 2,Y. Fan 2,S. Jin 2, X. Yang 2 1 Bureau International des Poids

More information

Summary of the ICRM Life Sciences Working Group Meeting

Summary of the ICRM Life Sciences Working Group Meeting Summary of the ICRM Life Sciences Working Group Meeting 19-20 November 201 National Physical Laboratory, Teddington, UK Jeffery T. Cessna Nuclear Medicine Metrology Meeting, 21 November 2014, NPL, Teddinton,

More information

Degrees of equivalence for the key comparison BIPM.RI(I)-K3 between national primary standards for medium-energy x-rays

Degrees of equivalence for the key comparison BIPM.RI(I)-K3 between national primary standards for medium-energy x-rays Degrees of equivalence for the key comparison BIPM.RI(I)-K3 between national primary standards for medium-energy x-rays D T Burns Bureau International des Poids et Mesures, Pavillon de Breteuil, F-92312

More information

The TDCR method in LSC. P. Cassette Laboratoire National Henri Becquerel CEA/LNE, France

The TDCR method in LSC. P. Cassette Laboratoire National Henri Becquerel CEA/LNE, France The TDCR method in LSC P. Cassette Laboratoire National Henri Becquerel CEA/LNE, France LIQUID SCINTILLATION USERS FORUM 2009 Summary I. Some information on LSC II. LSC in metrology: the free parameter

More information

Standardization of 18 F by Digital β(ls)-γ Coincidence Counting

Standardization of 18 F by Digital β(ls)-γ Coincidence Counting Standardization of 18 F by Digital β(ls)-γ Coincidence Counting Rodrigues D. 1, Balpardo C. 1, Cassette P. 2, Arenillas P. 1, Capoulat M. E. 1, Ceruti G. 1, García-Toraño E. 3 1 Laboratorio de Metrología

More information

Work Programme. of the International Bureau of Weights and Measures. for the four years Comité international des poids et mesures

Work Programme. of the International Bureau of Weights and Measures. for the four years Comité international des poids et mesures Work Programme of the International Bureau of Weights and Measures for the four years 2016-2019 Comité international des poids et mesures Section II : BIPM Work Programme for 2016-2019 35 Priority activities

More information

Key comparison BIPM.RI(I)-K4 of the absorbed dose to water standards of the METAS, Switzerland and the BIPM in 60 Co gamma radiation

Key comparison BIPM.RI(I)-K4 of the absorbed dose to water standards of the METAS, Switzerland and the BIPM in 60 Co gamma radiation Key comparison BIPM.RI(I)-K4 of the absorbed dose to water standards of the METAS, Switzerland and the BIPM in 60 Co gamma radiation C. Kessler 1, D.T. Burns 1, S. Vörös 2 and B. Hofstetter-Boillat 2 1

More information

Fundamentals of Radionuclide Metrology

Fundamentals of Radionuclide Metrology Fundamentals of Radionuclide Metrology Brian E. Zimmerman, PhD Physical Measurement Laboratory National Institute of Standards and Technology Gaithersburg, MD USA SIM Metrology Workshop Buenos Aires, Argentina

More information

ARTICLE IN PRESS. Applied Radiation and Isotopes

ARTICLE IN PRESS. Applied Radiation and Isotopes Applied Radiation and Isotopes 68 (21) 1349 1353 Contents lists available at ScienceDirect Applied Radiation and Isotopes journal homepage: www.elsevier.com/locate/apradiso Standardization and measurement

More information

*Corresponding author,

*Corresponding author, Horia Hulubei National Institute of Physics and Nuclear Engineering g - IFIN HH Horia Hulubei National Institute of Physics and Nuclear Engineering, IFIN-HH ROMANIA *Corresponding author, e-mail bercea@nipne.ro

More information

C2-05: Creation of national standards for some emerging pharmaceutical radionuclides to ensure the radioprotection of patients and medical staffs

C2-05: Creation of national standards for some emerging pharmaceutical radionuclides to ensure the radioprotection of patients and medical staffs C2-05: Creation of national standards for some emerging pharmaceutical radionuclides to ensure the radioprotection of patients and medical staffs Project Leaders: IFIN-HH/DRMR/LMR: Dr. Aurelian Luca ;

More information

CCRI(II) activity comparison of 241 Pu CCRI(II)-K2.Pu-241

CCRI(II) activity comparison of 241 Pu CCRI(II)-K2.Pu-241 Metrologia 49 (2012) Tech. Suppl. 06012 CCRI(II) activity comparison of 241 Pu CCRI(II)-K2.Pu-241 C. Michotte 1, L. Johansson 2 1 BIPM and 2 NPL Abstract In 2010, seven laboratories took part in the CCRI(II)

More information

Applied Radiation and Isotopes

Applied Radiation and Isotopes Applied Radiation and Isotopes 70 (2012) 2091 2096 Contents lists available at SciVerse ScienceDirect Applied Radiation and Isotopes journal homepage: www.elsevier.com/locate/apradiso Disintegration rate

More information

Determination of the activity of radionuclides

Determination of the activity of radionuclides BUREAU NATIONAL DE MÉTROLOGIE COMMISSARIAT À L'ÉNERGIE ATOMIQUE LABORATOIRE NATIONAL HENRI BECQUEREL Note technique LNHB/04-33 Determination of the activity of radionuclides contained in volume samples

More information

Comparisons of the standards for air kerma of the GUM and the BIPM for 60 Co and 137 Cs gamma radiation

Comparisons of the standards for air kerma of the GUM and the BIPM for 60 Co and 137 Cs gamma radiation Comparisons of the standards for air kerma of the GUM and the BIPM for 60 Co and 137 Cs gamma radiation P. J. Allisy-Roberts, C. Kessler, D.T. Burns Bureau International des Poids et Mesures, F-92312 Sèvres

More information

Primary Standardization of 152 Eu by 4πβ(LS) γ (NaI) coincidence counting and CIEMAT-NIST method

Primary Standardization of 152 Eu by 4πβ(LS) γ (NaI) coincidence counting and CIEMAT-NIST method Primary Standardization of 152 Eu by 4πβ(LS) γ (NaI) coincidence counting and CIEMAT-NIST method A Ruzzarin 1, P A L da Cruz 2, A L Ferreira Filho 2, A Iwahara 2 1 Laboratório de Instrumentação Nuclear/Programa

More information

Radioactivity standardization in South Africa

Radioactivity standardization in South Africa Applied Radiation and Isotopes 56 (2002) 301 305 Radioactivity standardization in South Africa B.R.S. Simpson* Radioactivity Standards Laboratory, CSIR NML, 15 Lower Hope Road, Rosebank 7700, Cape Town,

More information

Key comparison BIPM.RI(I)-K7 of the air-kerma standards of the CMI, Czech Republic and the BIPM in mammography x-rays

Key comparison BIPM.RI(I)-K7 of the air-kerma standards of the CMI, Czech Republic and the BIPM in mammography x-rays Key comparison BIPM.RI(I)-K7 of the air-kerma standards of the CMI, Czech Republic and the BIPM in mammography x-rays C Kessler 1, D T Burns 1, P Roger 1, V Sochor 2 1 Bureau International des Poids et

More information

19:00 21:30 Registration and reception at Hotel ETAP Altinel. Welcome

19:00 21:30 Registration and reception at Hotel ETAP Altinel. Welcome AGENDA FOR 5th VERMI YOUNG RESEARCHERS WORKSHOP ON STANDARDISATION OF S in the frame of IPA Turkey* 1 6 November 2009, TAEK, Ankara, Turkey Sunday, 1 November 2009 19:00 21:30 Registration and reception

More information

Euromet 907 124 Sb Activity measurement and determination of photon emission intensities Part A Euromet 907 Results 1. Introduction 2. Decay scheme of antimony 124 3. Programme and procedure 3.1. General

More information

Primary Standardisation of I-125

Primary Standardisation of I-125 Primary Standardisation of S. Pommé, T. Altzitzoglou, R. Van Ammel, G. Sibbens Institute for Reference Materials and Measurements (IRMM) Geel, Belgium http://www.irmm.jrc.be http://www.jrc.cec.eu.int Stefaan

More information

Ionizing Radiation Metrology at NMIJ/AIST and ENEA-INMRI

Ionizing Radiation Metrology at NMIJ/AIST and ENEA-INMRI Ionizing Radiation Metrology at NMIJ/AIST and ENEA-INMRI Pierino De Felice and Marco Capogni - ENEA C.R. Casaccia Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti (ENEA-INMRI) Roma ITALY Yoshio

More information

Comparison of the standards for absorbed dose to water of the ENEA-INMRI (Italy) and the BIPM for 60 Co γ rays

Comparison of the standards for absorbed dose to water of the ENEA-INMRI (Italy) and the BIPM for 60 Co γ rays Final Report 2010-01-12 Comparison of the standards for absorbed dose to water of the ENEA-INMRI (Italy) and the BIPM for 60 Co γ rays C. Kessler 1, P.J. Allisy-Roberts 1, D.T. Burns 1, A.S. Guerra 2,

More information

The BIPM key comparison database (KCDB): linkage of key comparison results

The BIPM key comparison database (KCDB): linkage of key comparison results The BIPM key comparison database (KCDB): linkage of key comparison results C. Thomas Bureau International des Poids et Mesures Pavillon de Breteuil, 92312 Sèvres Cedex, France Abstract The Appendix B of

More information

Recent Primary Standardisations and Traceability in Nuclear Medicine. Lena Johansson, NPL Radioactivity Group

Recent Primary Standardisations and Traceability in Nuclear Medicine. Lena Johansson, NPL Radioactivity Group Recent Primary Standardisations and Traceability in Nuclear Medicine Lena Johansson, NPL Radioactivity Group Outline Primary standards Introduction to primary standards of radioactivity and traceability

More information

EUROMET PROJECT FINAL REPORT

EUROMET PROJECT FINAL REPORT 1. Ref. No: 634 (please leave blank) EUROMET PROJECT FINAL REPORT 2. Subject Field: Ionizing radiation 3. Type of collaboration: comparison 4A: Partners: (institutions) ČMI, BEV, SMÚ 5. Participating countries:

More information

Bureau International des Poids et Mesures

Bureau International des Poids et Mesures Rapport BIPM 02/01 Bureau International des Poids et Mesures Comparison of the standards of air kerma of the Yugoslavia and the BIPM for 60 Co γ rays by P.J. Allisy-Roberts, D.T. Burns, C Kessler BIPM

More information

Activity measurement of 55 Fe within the scope of the BIPM comparison 2006

Activity measurement of 55 Fe within the scope of the BIPM comparison 2006 Activity measurement of 55 Fe within the scope of the BIPM comparison 2006 Karsten Kossert PTB, Department 6.1 Radioactivity BIPM Workshop 2 on CCRI(II) Activity Uncertainties and Comparisons, 17-18 September

More information

THE SUPPORT OFFERED BY THE ROMANIAN PRIMARY ACTIVITY STANDARD LABORATORY TO THE NUCLEAR MEDICINE FIELD *

THE SUPPORT OFFERED BY THE ROMANIAN PRIMARY ACTIVITY STANDARD LABORATORY TO THE NUCLEAR MEDICINE FIELD * NUCLEAR MEDICINE THE SUPPORT OFFERED BY THE ROMANIAN PRIMARY ACTIVITY STANDARD LABORATORY TO THE NUCLEAR MEDICINE FIELD * M. SAHAGIA, A. ANTOHE, A. LUCA, A.C. WÄTJEN, C. IVAN Horia Hulubei National Institute

More information

Key comparison BIPM.RI(I)-K3 of the air-kerma standards of the NRC, Canada and the BIPM in medium-energy x-rays

Key comparison BIPM.RI(I)-K3 of the air-kerma standards of the NRC, Canada and the BIPM in medium-energy x-rays Key comparison BIPM.RI(I)-K3 of the air-kerma standards of the NRC, Canada and the BIPM in medium-energy x-rays D T Burns 1, C Kessler 1, E Mainegra-Hing 2, H Shen 2 and M R McEwen 2 1 Bureau International

More information

Bureau International des Poids et Mesures

Bureau International des Poids et Mesures Bureau International des Poids et Mesures Comparison of the air-kerma standards of the ENEA-INMRI and the BIPM in the low-energy x-ray range D.T. Burns, M.P. Toni and M. Bovi November 1999 Pavillon de

More information

Final Report on APMP.M.M-K4.1 - Bilateral Comparison of 1 kg Stainless Steel Mass Standards between KRISS and A*STAR

Final Report on APMP.M.M-K4.1 - Bilateral Comparison of 1 kg Stainless Steel Mass Standards between KRISS and A*STAR Final Report on APMP.M.M-K4.1 - Bilateral Comparison of 1 kg Stainless Steel Mass Standards between KRISS and A*STAR Jin Wan Chung 1, Shih Mean Lee, Sungjun Lee 1 1 Korea Research Institute of Standards

More information

Čerenkov counting and liquid scintillation counting of 36 Cl

Čerenkov counting and liquid scintillation counting of 36 Cl Čerenkov counting and liquid scintillation counting of 36 Cl Karsten Kossert, Ole Nähle Physikalisch-Technische Bundesanstalt (PTB), Braunschweig, Germany and Agustín Grau Carles Instituto de Física Fundamental

More information

Derivation of Calibration Factors and Dial Settings Michaela Baker

Derivation of Calibration Factors and Dial Settings Michaela Baker Derivation of Calibration Factors and Dial Settings Michaela Baker 29 November 2012 NPL Secondary standard ion chamber Direct calibration with NPL primary standards: - Photon emitting radionuclides - High

More information

abstractnumber.doc The Support Offered by the Romanian Primary Activity Standard Laboratory to the Nuclear Medicine Field

abstractnumber.doc The Support Offered by the Romanian Primary Activity Standard Laboratory to the Nuclear Medicine Field abstractnumber.doc2353248 The Support Offered by the Romanian Primary Activity Standard Laboratory to the Nuclear Medicine Field Maria Sahagia*, Andrei Antohe, Aurelian Luca, Anamaria Cristina Wätjen,

More information

Monte Carlo simulations as a tool for the development of a new reference ionisation chamber

Monte Carlo simulations as a tool for the development of a new reference ionisation chamber Monte Carlo simulations as a tool for the development of a new reference ionisation chamber Johan Camps, Jan Paepen, Stefaan Pommé and Uwe Wätjen Institute for Reference Materials and Measurements (IRMM)

More information

INTERNATIONAL COMPARISON OF WATER TRIPLE POINT CELLS LEADING TO A MORE PRECISE DEFINITION OF THE KELVIN

INTERNATIONAL COMPARISON OF WATER TRIPLE POINT CELLS LEADING TO A MORE PRECISE DEFINITION OF THE KELVIN INTERNATIONAL COMPARISON OF WATER TRIPLE POINT CELLS LEADING TO A MORE PRECISE DEFINITION OF THE KELVIN Michael Stock and Stéphane Solve Bureau International des Poids et Mesures (BIPM) Pavillon de Breteuil,

More information

TDCR in a nutshell. P. Cassette, Laboratoire National Henri Becquerel, France

TDCR in a nutshell. P. Cassette, Laboratoire National Henri Becquerel, France TDCR in a nutshell P. Cassette, Laboratoire National Henri Becquerel, France Summary LSC in radionuclide metrology, free parameter model The TDCR model Examples of relations between efficiency and TDCR

More information

CCM short note on the dissemination process after the proposed redefinition of the kilogram

CCM short note on the dissemination process after the proposed redefinition of the kilogram CCM short note on the dissemination process after the proposed redefinition of the kilogram Consultative Committee for Mass and Related Quantities 1. Introduction This note proposes how the mise en pratique

More information

RADIOPHARMACEUTICAL 11 C ACTIVITY MEASUREMENTS BY MEANS OF THE TDCR-CERENKOV METHOD BASED ON A GEANT4 STOCHASTIC MODELING

RADIOPHARMACEUTICAL 11 C ACTIVITY MEASUREMENTS BY MEANS OF THE TDCR-CERENKOV METHOD BASED ON A GEANT4 STOCHASTIC MODELING C:\Documents and Settings\Mark McClure\Desktop\LSC2010\P-21- Thiam.fm printed: 27 July 2011 PAGE PROOF MM AUTHOR S PROOF Please check carefully and return any corrections via email as soon as possible

More information

1. Introduction. 2. Evaluation Techniques

1. Introduction. 2. Evaluation Techniques EPJ Web of Conferences 106, 04010 (2016) DOI: 10.1051/epjconf/201610604010 C Owned by the authors, published by EDP Sciences, 2016 Nuclear Decay Data for the International Reactor Dosimetry Library for

More information

Key comparison BIPM.RI(I)-K3 of the air-kerma standards of the BEV, Austria and the BIPM in medium-energy x-rays

Key comparison BIPM.RI(I)-K3 of the air-kerma standards of the BEV, Austria and the BIPM in medium-energy x-rays Key comparison BIPM.RI(I)-K3 of the air-kerma standards of the BEV, Austria and the BIPM in medium-energy x-rays D.T. Burns, W. Tiefenböck* and J. Witzani* Bureau International des Poids et Mesures, Pavillon

More information

Library of uranium and plutonium reference spectra Introduction

Library of uranium and plutonium reference spectra Introduction Library of uranium and plutonium reference spectra Introduction Due to the difficulties in procuring and circulating certified uranium or plutonium samples, the ESARDA Working Group on Techniques and Standards

More information

Development of Radioactivity Standards for Quantitative Positron Emission Tomography

Development of Radioactivity Standards for Quantitative Positron Emission Tomography Development of Radioactivity Standards for Quantitative Positron Emission Tomography Brian E. Zimmerman, PhD Radiation Physics Division National Institute of Standards and Technology Gaithersburg, MD 20899-8462

More information

Adaptation of PTB s analytical modelling for TDCR-Cherenkov activity measurements at LNE-LNHB. LSC 2017, Copenhagen, 1-5 May 2017

Adaptation of PTB s analytical modelling for TDCR-Cherenkov activity measurements at LNE-LNHB. LSC 2017, Copenhagen, 1-5 May 2017 Adaptation of PTB s analytical modelling for TDCR-Cherenkov activity measurements at LNE-LNHB Cheick THIAM, Christophe BOBIN and Jacques BOUCHARD LSC 2017, Copenhagen, 1-5 May 2017 General introduction

More information

Activity determination of 88 Y by means of 4πβ(LS)-γ coincidence counting

Activity determination of 88 Y by means of 4πβ(LS)-γ coincidence counting Activity determination of 88 Y by means of 4πβ(LS)-γ coincidence counting Justyna Marganiec-Galazka Ole J. Nähle Karsten Kossert Division 6 Ionizing Radiation Department 6.1 Radioactivity Working Group

More information

Measurement modelling of the International Reference System (SIR) for gamma emitting radionuclides

Measurement modelling of the International Reference System (SIR) for gamma emitting radionuclides Monographie BIPM-7 Measurement modelling of the International Reference System (SIR) for gamma emitting radionuclides Maurice G. Cox, Carine Michotte, Andy K. Pearce December 2007 BUREAU INTERNATIONAL

More information

ETNA (Efficiency Transfer for Nuclide Activity measurement)

ETNA (Efficiency Transfer for Nuclide Activity measurement) ETNA (Efficiency Transfer for Nuclide Activity measurement) ETNA is a software for computing efficiency transfer and coincidence summing corrections for gamma-ray spectrometry. The software has been developed

More information

AFRIMETS. Supplementary Comparison Programme. Calibration of Gauge Blocks. by Mechanical Comparison Method AFRIMETS.L S3.

AFRIMETS. Supplementary Comparison Programme. Calibration of Gauge Blocks. by Mechanical Comparison Method AFRIMETS.L S3. AFRIMETS Secretariat Private Bag X34 Lynnwood Ridge 0040 AFRIMETS Supplementary Comparison Programme Calibration of Gauge Blocks by Mechanical Comparison Method AFRIMETS.L S3 Final Report Giza, Egypt,

More information

INTERNATIONAL KEY COMPARISON OF MEASUREMENTS OF NEUTRON SOURCE EMISSION RATE ( ) CCRI(III)-K9.AmBe

INTERNATIONAL KEY COMPARISON OF MEASUREMENTS OF NEUTRON SOURCE EMISSION RATE ( ) CCRI(III)-K9.AmBe INTERNATIONAL KEY COMPARISON OF MEASUREMENTS OF NEUTRON SOURCE EMISSION RATE (1999-2005) CCRI(III)-K9.AmBe N.J. Roberts 1 * and L.N. Jones National Physical Laboratory (NPL), Teddington, UK Z. Wang, Y.

More information

Final Report August 2010

Final Report August 2010 Bilateral Comparison of 100 pf Capacitance Standards (ongoing BIPM key comparison BIPM.EM-K14.b) between the CMI, Czech Republic and the BIPM, January-July 2009 J. Streit** and N. Fletcher* *Bureau International

More information

Comparison of the air kerma standards for 137 Cs and 60 Co gamma-ray beams between the IAEA and the NIST. Ronaldo Minniti 1 and Ladislav Czap 2

Comparison of the air kerma standards for 137 Cs and 60 Co gamma-ray beams between the IAEA and the NIST. Ronaldo Minniti 1 and Ladislav Czap 2 Comparison of the air kerma standards for 137 Cs and 60 Co gamma-ray beams between the IAEA and the NIST Ronaldo Minniti 1 and Ladislav Czap 2 1 National Institute of Standards and Technology (NIST), Gaithersburg,

More information

Final Report for CCRI(II)-S1 13 October Activity measurements of a suite of radionuclides ( 40 K, 137 Cs, 210 Pb, 210 Po, 228 Ra, 232 Th, 234 U,

Final Report for CCRI(II)-S1 13 October Activity measurements of a suite of radionuclides ( 40 K, 137 Cs, 210 Pb, 210 Po, 228 Ra, 232 Th, 234 U, Activity measurements of a suite of radionuclides ( 40 K, 137 Cs, 210 Pb, 210 Po, 228 Ra, 232 Th, 234 U, 235 U, 238 U, 238 Pu, 239 Pu, 239+240 Pu, 241 Am) in vegetal reference material (seaweed) Abstract

More information

Disproof of solar influence on the decay rates of 90 Sr/ 90 Y

Disproof of solar influence on the decay rates of 90 Sr/ 90 Y Disproof of solar influence on the decay rates of 90 Sr/ 90 Y Karsten Kossert * and Ole J. Nähle Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig, Germany Abstract A custom-built

More information

Final Report 06 July 2006 Frank Wilkinson, Gan Xu, and Yuanjie Liu

Final Report 06 July 2006 Frank Wilkinson, Gan Xu, and Yuanjie Liu Bilateral Comparison of between NMIA (Australia) and SPRING (Singapore) (KCDB reference No. CCPR-K1.a.1) Final Report 06 July 2006 Frank Wilkinson, Gan Xu, and Yuanjie Liu Contents 1. Introduction..2 2.

More information

EUROMET Project 702 EUROMET.M.D-K4

EUROMET Project 702 EUROMET.M.D-K4 EUROMET TC-M Meeting 2007 Thursday, 01 March 2007 EUROMET Project 702 EUROMET.M.D-K4 Comparison of the calibrations of high resolution hydrometers for liquid density determinations Salvatore Lorefice INRIM,

More information

TDCR and CIEMAT/NIST Liquid Scintillation Methods applied to the Radionuclide Metrology

TDCR and CIEMAT/NIST Liquid Scintillation Methods applied to the Radionuclide Metrology TDCR and CIEMAT/NIST Liquid Scintillation Methods applied to the Radionuclide Metrology Paulo A. L. da Cruz 1, Carlos J. da Silva 1, Akira Iwahara 1, Jamir S. Loureiro 1, Antônio E. de Oliveira 1, Luiz

More information

CCQM-K27.2 Second Subsequent Study: Determination of Ethanol in Aqueous Media Final Report

CCQM-K27.2 Second Subsequent Study: Determination of Ethanol in Aqueous Media Final Report CCQM-K27.2 Second Subsequent Study: Determination of Ethanol in Aqueous Media Final Report Michele M. Schantz, Reenie M. Parris, and Willie E. May National Institute of Standards and Technology (NIST)

More information

Intercomparison of 131 I and 99m Tc Activity Measurements in Brazilian Nuclear Medicine Services

Intercomparison of 131 I and 99m Tc Activity Measurements in Brazilian Nuclear Medicine Services Intercomparison of 131 I and 99m Tc Activity Measurements in Brazilian Nuclear Medicine Services A. Iwahara 1, A. E. de Oliveira 1, L. Tauhata 1, C. J. da Silva 1 and R. T. Lopes 2 1 Laboratório Nacional

More information

BIPM Key Comparison BIPM.RI(I)-K6 PROTOCOL 3.0 CCRI(I) 6 November 2017

BIPM Key Comparison BIPM.RI(I)-K6 PROTOCOL 3.0 CCRI(I) 6 November 2017 COMPARISON OF ABSORBED DOSE TO WATER AT HIGH PHOTON ENERGIES AT A REFERENCE FACILITY BIPM Key Comparison BIPM.RI(I)-K6 PROTOCOL 3.0 CCRI(I) 6 November 2017 Bureau International des Poids et Mesures Pavillon

More information

Quality Assurance. Purity control. Polycrystalline Ingots

Quality Assurance. Purity control. Polycrystalline Ingots Quality Assurance Purity control Polycrystalline Ingots 1 Gamma Spectrometry Nuclide Identification Detection of Impurity Traces 1.1 Nuclides Notation: Atomic Mass Atomic Number Element Neutron Atomic

More information

Abstract An indirect comparison of the standards for reference air kerma rate for

Abstract An indirect comparison of the standards for reference air kerma rate for Comparison BIPM.RI(I)-K8 of high dose-rate Ir-19 brachyerapy standards for reference air kerma rate of e VSL and e BIPM J.T. Alvarez 1, J. A. de Pooter, C. Andersen 3, A.H.L. Aalbers, P.J. Allisy-Roberts

More information

Comparison of the standards of air kerma of the GUM and the BIPM for 60Co 'Y rays

Comparison of the standards of air kerma of the GUM and the BIPM for 60Co 'Y rays Rapport BIPM-9712 Comparison of the standards of air kerma of the GUM and the BIPM for 60Co 'Y rays by P.J. Allisy-Roberts and M. Boutillon Bureau International des Poids et Mesures, F-92312 Sevres Cedex,

More information

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN 316 Effective atomic number of composite materials by Compton scattering - nondestructive evaluation method Kiran K U a, Ravindraswami K b, Eshwarappa K M a and Somashekarappa H M c* a Government Science

More information

Final Report for CCRI(II)-S2 CCRI(II)-S2. S. Nour*, K. G. W. Inn, L. R. Karam *University of Maryland, USA; NIST, USA

Final Report for CCRI(II)-S2 CCRI(II)-S2. S. Nour*, K. G. W. Inn, L. R. Karam *University of Maryland, USA; NIST, USA Activity measurements of a suite of radionuclides ( 90 Sr, 137 Cs, 210 Pb, 210 Po, 228 Ra, 234 U, 235 U, 238 U, 238 Pu, 239,240 Pu) in soil reference material (Rocky Flats II) CCRI(II)-S2 Abstract S. Nour*,

More information

Radiation Detection and Measurement

Radiation Detection and Measurement Radiation Detection and Measurement June 2008 Tom Lewellen Tkldog@u.washington.edu Types of radiation relevant to Nuclear Medicine Particle Symbol Mass (MeV/c 2 ) Charge Electron e-,! - 0.511-1 Positron

More information

Investigation of Uncertainty Sources in the Determination of Gamma Emitting Radionuclides in the UAL

Investigation of Uncertainty Sources in the Determination of Gamma Emitting Radionuclides in the UAL Investigation of Uncertainty Sources in the Determination of Gamma Emitting Radionuclides in the UAL A. Specification Gamma-spectrometry method is used to identify and determine the activity concentration

More information

Bureau International des Poids et Mesures

Bureau International des Poids et Mesures Bureau International des Poids et Mesures Comparison of the air-kerma standards of the VNIIM and the BIPM in the medium-energy x-ray range D.T. Burns, N.D. Villevalde, A.V. Oborin and E.N. Yurjatin September

More information

Detection of 106 Ru, via the decay of its daughter 106 Rh, in gammaray

Detection of 106 Ru, via the decay of its daughter 106 Rh, in gammaray Detection of 106 Ru, via the decay of its daughter 106 Rh, in gammaray spectra Technical considerations for laboratory work Mikael Hult and Guillaume Lutter 2017 EUR 28850 EN xxxxx xx This publication

More information

J. Keightley 1 P. Cassette 2, L. Johansson 1

J. Keightley 1 P. Cassette 2, L. Johansson 1 RADIONUCLIDE METROLOGY FOR NEW GENERATION NUCLEAR POWER PLANTS J. Keightley 1 P. Cassette 2, L. Johansson 1 1 NPL, Teddington, United Kingdom 2 CEA-LNHB, Saclay, France E-mail (corresponding author): john.keightley@npl.co.uk

More information

CCRI(II)/ Report of the NIST Radioactivity Group to CCRI Section II

CCRI(II)/ Report of the NIST Radioactivity Group to CCRI Section II Report of the NIST Radioactivity Group to CCRI Section II Michael P. Unterweger Leader, Radioactivity Group Radiation and Biomolecular Physics Division Physical Measurement Laboratory National Institute

More information

Absolute activity measurement

Absolute activity measurement Absolute activity measurement Gábor Veres, Sándor Lökös Eötvös University, Department of Atomic Physics January 12, 2016 Financed from the financial support ELTE won from the Higher Education Restructuring

More information

Preparation of nitrous oxide (N 2 O) in air standard being traceable to SI by gravimetric method

Preparation of nitrous oxide (N 2 O) in air standard being traceable to SI by gravimetric method Preparation of nitrous oxide ( O) in air standard being traceable to SI by gravimetric method 15th WMO Meeting of Experts on Carbon Dioxide, Other Greenhouse Gases, and Related Tracer Measurement Techniques

More information

Metrology for Molecular Radiotherapy MetroMRT V. Smyth (coordinator) Lena Johansson, Andrew Fenwick, Kelley Ferreira et al.

Metrology for Molecular Radiotherapy MetroMRT V. Smyth (coordinator) Lena Johansson, Andrew Fenwick, Kelley Ferreira et al. EMRP Health(II) Metrology for Molecular Radiotherapy MetroMRT V. Smyth (coordinator) Lena Johansson, Andrew Fenwick, Kelley Ferreira et al. Metro-MRT Metrology for Molecular Radiotherapy, 2012-2015 WP

More information

Metrology Principles for Earth Observation: the NMI view. Emma Woolliams 17 th October 2017

Metrology Principles for Earth Observation: the NMI view. Emma Woolliams 17 th October 2017 Metrology Principles for Earth Observation: the NMI view Emma Woolliams 17 th October 2017 Interoperability Decadal Stability Radiometric Accuracy Identical worldwide Century-long stability Absolute accuracy

More information

Measurement of the 30 Si mole fraction in the new Avogadro silicon material by Neutron Activation and high resolution spectrometry

Measurement of the 30 Si mole fraction in the new Avogadro silicon material by Neutron Activation and high resolution spectrometry Measurement of the 30 Si mole fraction in the new Avogadro silicon material by Neutron Activation and high resolution spectrometry Marco Di Luzio 1,2, Attila Stopic 3, Giancarlo D Agostino 1, John W Bennett

More information

Consistency and confidence: the role of the National Measurement System

Consistency and confidence: the role of the National Measurement System Consistency and confidence: the role of the National Measurement System Dr. Martyn Sené Deputy Director, NPL 30 th June, 2011 Welcome to the National Physical Laboratory Consistent measurement - important

More information

SYSTEM OF MONITORING THE ATMOSPHERICAL RADON WITH AN IONIZATION CHAMBER DETECTOR TYPE IN PULSE MODE

SYSTEM OF MONITORING THE ATMOSPHERICAL RADON WITH AN IONIZATION CHAMBER DETECTOR TYPE IN PULSE MODE SYSTEM OF MONITORING THE ATMOSPHERICAL RADON WITH AN IONIZATION CHAMBER DETECTOR TYPE IN PULSE MODE Marian Romeo Călin, Adrian Cantemir Călin Horia Hulubei National Institute of Physics and Nuclear Engineering

More information

Final report on CCQM-K36.1 with erratum

Final report on CCQM-K36.1 with erratum Final report on CCQM-K36.1 with erratum 5 October 2010 Ref 1107-03 HDJ Report no. DFM-2008-R07 Summary A follow-up comparison to CCQM-K36 has been carried out November 2007 to February 2008, designated

More information

Australian Primary and Secondary Standard of Activity: Standardisation of F-18

Australian Primary and Secondary Standard of Activity: Standardisation of F-18 AU0221630 Australian Primary and Secondary Standard of Activity: Standardisation of F-18 M.I. REINHARD, L. MO and D. ALEXIEV Radiation Technology and Standards Group, Physics Division, Australian Nuclear

More information